Loading...
ENG2022-0213 ROW PERMITOF EI�� ~ � O RIGHT OFPERMIT City of Edmonds PERMIT NUMBE Edmonds WA 9:1 1 �1 i gad • - • • • • • 022401 Description: PUD -REPLACE 11 BO POLES (EXPIRED APPLICATION ENG2020-0361) ISSUED: 06/13/2022 Address: 915 MAPLE ST EDMONDS WA 98020-3330 EXPIRES: 12/13/2022 Permit Type: RIGHT OF WAY EUC Permit Subtype: STANDARD Parcel Number: 00434206903500 CONTACTS NAME TYPE NAME ADDRESS PHONE APPLICANT MOE NAVE PO BOX 1107, EVERETT WA 98206 (425)783-5681 CONTACT SNOHOMISH COUNTY PUD PO BOX 1107, EVERETT WA 98206 (425)783-4355 CONTRACTOR SNOHOMISH COUNTY PUD P.O. BOX 1107, EVERETT WA 98206 (425)670-3216 OWNER BRIAN J\HEIDI G PFLUGRATH 915 MAPLE ST, EDMONDS WA 98020 FEE INFORMATION DESCRIPTION AMOUNT PAID CITY TECHNOLOGY FEE CHARGED PER PERMIT $40.00 $40.00 ENGINEERING INSPECTION FEE $330.00 $330.00 RIGHT OF WAY STANDARD - EUC PERMIT FEE $330.00 $330.00 • REQUIREMENT TYPE NOTES TRAFFIC CONTROL Traffic control and public safety shall be in accordance with City regulations as required by the City Engineer. Every flagger must be trained as required by WAC 296-155-305 and must have certification verifying completion of the required training in their posession. RESTORATION Restoration is to be in accordance with City codes. All street -cut trench work shall be patched with asphalt or City approved material prior to the end of the workday - No Exceptions WARRANTY The contractor is responsible for workmanship and materials for a period of one year following the final inspection and acceptance of the work. INSPECTION SCHEDULING: WWW.MYBUILDING PERMIT.COM 24 HR NOTICE REQUIRED The Applicant has signed an application which states he/she holds the City of Edmonds harmless from injuries, damages or claims of any kind or description whatsoever, foreseen or unforeseen, that may be made against the City of Edmonds or any of its departments or employees, including but not limited to the defense of any legal proceedings including defense costs and attorney fees by reason of granting this permit. THIS DOCUMENT IS NOT VALID UNTIL FEES ARE PAID AND THE CITY ENGINEER OR HIS/HER DEPUTY HAS SIGNED BELOW 06/13/2022 RELEASED BY DATE Printed: Monday, June 13, 2022 11:45:18 AM 1 of 2 RIGHT OF WAY EUC PERMIT City of Edmonds PERMIT NUMBER, - 98020ENG2022-0213 www.cityofedmonds.gov / 425i CONDITIONS CONDITION TYPE NOTES ALERT RESIDENTS ALERT AFFECTED RESIDENTS AND OR BUSINESSES PRIOR TO WORK START. It is the owner's responsibility to repair/replace all damage of utilities or frontage improvements in DAMAGE TO FRONTAGE City right of Ways or Easements to City Standards caused by or occurring during the permitted IMPROVEMENTS project. MAINTAIN EROSION AND SEDIMENTATION CONTROL PER CITY AND SWMMW STANDARD ESC REQUIREMENTS REQUIREMENTS. Applicant, on behalf of his or her spouse, heirs, assigns, and successors in interests, agrees to indemnify defend and hold harmless the City of Edmonds, Washington, its officials, employees, and agents from any and all claims for damages of whatever nature, arising directly or indirectly from the HOLD HARMLESS issuance for this permit. Issuance of this permit shall not be deemed to modify, waive or reduce any requirements of any City ordinance nor limit in any way the City's ability to enforce any ordinance provision. SCHEDULE REQUIRED INSPECTIONS AS NOTED THROUGH MY BUILDING PERMIT. INSPECTIONS www.mybuildingpermit.com POTHOLING VERIFY CLEAR BORE CROSSINGS. RESTORE LANDSCAPE Restore landscape to like or better conditions Sound or noise originating from temporary construction sites as a result of construction activity are exempt from the noise limits of ECC Chapter 5.30 only during the hours of 7:00am to 6:00pm on SOUND AND NOISE weekdays and 10:00am and 6:00pm on Saturdays, excluding Sundays and Federal Holidays. At all other times the noise originating from construction sites and activities must comply with the noise limits of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120. All utilities shall be located prior to any excavation. New locates shall be called for if at time of UTILITY LOCATES excavation, original locates are no longer identifiable. INSPECTIONS INSPECTION TYPE DATE RESULT NOTES COMPLETE A-1 JOB START X-2 ENGINEERING FINAL" E-7 TRAFFIC CTRL E-7 CURB RAMP E-7 CONCRETE SIDEWALK E-7 CURB GUTTER E-7 RESTOR LIMITS E-7 TRAFFIC CTRL Printed: Monday, June 13, 2022 11:45:18 AM 2 of 2 Of EDAgO�O� RECEIVED RIGHT OF WAY CONSTRUCTION MAY 04 2022 PERMIT APPLICATION CITY OF EDMONDS �I Complete and submit this Application in accordance with the Submittal DEVELOPMENT /,%/C. 1390 Requirements outlined in Right -of -Way permit Handout E63. SERVICES DEPARTMENT If any field is not applicable to your project, write "N/A" instead of leaving blank. All fields required. Incomplete Applications will be denied. SECTION A General • Project Name Replace 11 Utility Poles Site Address or if no site address use Property Address at NW corner of project area: 915 Maple St. Associated Permits: BLD N/A PLN N/A IENG ENG2020-0361 HoldingOwner and Entity Name of Company Snohomish County PUD #1 Franchise Ordinance No: N/A Point of Contact Ben Ice Title Engineer Address PO Box 1107 City Everett State WA Zip 98206 Phone 425.783.4355 Email btice@snopud.com Contractor and Authorized Agent of Owner Name of Company Same as above (see note below) Contractor Contacts During Construction Primary Name Agent Name Title Title Mobile Address Email City State Zip Secondary Name Phone Title Email Mobile City of Edmonds Business License No: Email State License No: 313-005-741 0 Contractor verifies it is currently bonded ® Contractor verifies it currently has general liability insurance NOTE: ECDC 18.6o.o2o requires that the Application be signed by a licensed and bonded contractor unless otherwise approved by the city engineer. ❑ Multifamily residential ❑ Commercial ❑ City project ❑ Single family residential subdivision ❑ Single family -other ❑ Industrial ❑ Demo and rebuild or from vacant land? ❑ Other, please specify: ❑ Utility Franchise Work associated with development (check one of the above boxes as welt ❑ Traffic Control Only (no associated development) • Utility Franchise Work (no associated development) City of Edmonds ROW construction permit Application --Page 1 of 3 Updated 3/25/2021 Include an overall narrative description of the proposed work. Be specific and detailed: Describe infrastructure to be impacted, such as, poles, wires, conduit, utility mains, etc. Include whether this is construction, maintenance, or repair. Include description of proposed construction methods, (e.g., bores, trenches, overhead wires proposed, depth for underground utilities, etc.) Replacing 11 old utility poles with new. The final height of the new poles will be the same as the old ones. The poles are being moved as far from the pavement as is feasible given the existing property rights. All poles in the sidewalk are moving behind the sidewalk. Work will include the necessary tree trimming. Reapplication for same set of poles as ENG2020-0360 with a different PUD work order. Work will take place during normal work hours, subject to city ordinance. Anticipated duration per location: 2 days. RIGHT-OF-WAY CLOSURE AREA TOTAL DURATION (Number of Months) Sidewalk 72 hours + LF I x LF SF Alley 72 hours + LF Ix I LF SF Parking 72 hours + LF Ix I LF SF SECTION B - If you are not a utility company performing work in the City ROW, skip to SECTIONC. 1. The work in the right of way is on or for the following type of facilities: ❑ telecommunications ❑ cable n power ❑ gas ❑ water ❑ sewer ❑ storm Details of Work to be Completed 1. Does the utility owner have existing overhead infrastructure in the area of work? Yes x No 2. 1 Will any equipment be added underground or above ground (e.g. pedestals, vaults, etc.)? x If yes, describe: 3. Does the proposed work connect a lot or commercial development with utilities that serve more than one lot or commercial development? X 4. Does the work involve rebuilding or relocating an existing aboveground utility system which connects a lot or commercial development to an existing underground common utility stem? X 5. Does the work involve proposed additions to an aboveground utility system? If es: x Are the additions for the purpose of serving new commercial development? Are the additions for the purpose of serving a single-family residential subdivision? Details of • to be Completed Yes No 6. Does your project involve rebuilding or replacing utility equipment which currently serves more than one lot or commercial development? If yes, answer the following questions related to project area, i.e. the actual area in which the x project is proposed: 6a. Does your project involve wires/cables/lines? If yes: X How many are existing? 14 1 How many are to be added? I o City of Edmonds ROW construction permit Application --Page 2 of 3 Updated 3/25/2021 6b. Does your project involve poles? If yes: x How many poles are existing in the project area? 11 What is the height of the existing poles? 45 How many poles are to be removed? o Are additional poles to be laced? X How many? I I What is the height of the additionalpoles? 6c. Are any poles to be modified/rebuilt/replaced? If yes: X How many? 1 11 1 What is the height of the poles after? 145 Describe the modification rebuild: Replace Pole, transfer equipment SECTION C Traffic Control and Public Safety. Traffic control and public safety shall be in accordance with City regulations as required by the City Engineer. Every flagger must be trained as required by WAC 296-155-305 and must have certification verifying completion of the required training in their possession. Restoration. Restoration shall be in accordance with City codes and Standards. All street cut trench work shall be patched with asphalt or City approved material prior to the end of the workday -NO EXCEPTIONS. Insurance. The City may require the owner or contractor to provide proof of insurance acceptable to the City prior to any permit approval. Indemnification. The Applicant agrees to defend, indemnify, and hold harmless the City of Edmonds, its officials, officers, employees, and agents against any injuries, damages, or claims of any kind or description whatsoever, foreseen or unforeseen, including defense costs and attorney fees, resulting directly or indirectly from any act or omission of the Applicant, its subcontractors, anyone directly or indirectly employed by them, and anyone for whose acts or omissions they may be liable, arising out of, related to, or by reason of the granting of this permit; and specifically including but not limited to all loss by the failure of the Applicant to fully or adequately perform, in any respect, all authorizations or obligations under the permit. These indemnification requirements shall survive the expiration, revocation, or termination of any resulting permit approval. Acceptance of terms, conditions, and requirements. Applicant accepts the terms, conditions, and requirements set forth in this Application and agrees they apply to any resulting permit and shall comply with them to the satisfaction of the City Engineer. Applicant further agrees to comply with the conditions listed on the Submittal Requirements; with all applicable city ordinances, including but not limited to ECDC Title 18; and with all applicable requirements of state and federal law. Statement of Applicant. I declare under penalty of perjury under the laws of the State of Washington that: I am a licensed and bonded contractor; the information provided herein is correct and complete; and I am authorized by owner to act on its behalf and have authority to bind the owner to this application. Fees. The Applicant is responsible for all permit fees. APPLICANT SIGNATURE: DATE: 5i3i2022 APPLICANT PRINTED NAME: Benjamin ice APPLICANT TITLE: engineer NO WORK SHALL BEGIN PRIOR TO PERMIT ISSUANCE City of Edmonds ROW construction permit Application --Page 3 of 3 Updated 3/25/2021 SCHEDULE ALL INSPECTIONS THROUGH MYBUILDINGPERMIT.COM N NORTH C/'D Q S O FU100 01 915 21 933 945 951 951 909 P 950 �'S3 50-351760 952 15-919 SL-129183-A P15-343908 -------------- O P - -- S T U ------------------- 0 92 934 93 14 9 946 M-CDG 14 20 35 SL1 925 982 318 12794-H 15-391834 P O SL-130492-A - O P 926 932-M-CM 979 SN 12-1517 P 942 95 951 953 SL 109513-A O O MAPI F CT PLAN VIEW - PUD TO ENFORCE POLE ATU&MENT AGREEMENT. - PUD IS RESPONSIBLE FOR ENSURING THAT THE OLD POLES ARE REMOVED. OS POLE PLI # 950 SET 45'CL 2 POLE (PW2045), 5'N SET DEPTH = 6.5' ROW LINE USE 5/g' GRVL BCKFLL, CMPCT IN 6" LFTS NEW POLE FRAME 10 DDE ASSY (12V11U RMV 15 KVA OH XFMR 6' UTC #----------------- OLD POLE (� T SER# 1 CURB HANG 15 KVA OH XFMR (BA21L, 12V60D UTC # ------------------ SER# ---------------- XFR OH SVCS RMV EXIST SEC UG RISER INSTL 3' SEC RISER & 4 POS RED OU705) RUN 350 KCMIL TPX TO PED L= 40' OT POLE PLI # 951 ROW LINE SET 45' CL 2 POLE (PW2045), 5' N SET DEPTH = 6.5' NEW POLE USE 5/8' GRVL BCKFLL, CMPCT IN 6" LFTS FRAME 10 TANG ASSY (12V101) 6, XFR 50 KVA XFMR 50-351760 (12V601) OLD POLE (� T XFR OH SVCS RMV EXIST SEC UG RISER 19 INSTL 3SEC RISER & 4 POS PED OU705) CURB RUN 350 KCMIL TPX TO PED L= 40' INSTL 12'STLT ARM (LO505) FACING S XFR LUMINAIRE # SL-129783-A OU POLE PLI # 952 ROW LINE SET 45' CL 2 POLE (PW2045), 5' N SET DEPTH = 6.5' NEW POLE ST USE 5/8" GRVL BCKFLL, CMPCT IN 6" LFTS FRAME 10 TANG ASSY (12V101) 6' XFR 75 KVA XFMR 75-343908 (12V601) XFR OH SVCS OLD POLE T RMV EXIST SEC UG RISER 1' INSTL 3' SEC RISER & 4 POS PED OU705) CURB RUN 350 KCMIL TPX TO PED L= 40' g' OV POLE PLI # 953 ROW LINE SET 45' CL 2 POLE (PW2045), 5' N POLE SET DEPTH = USE 5/8' GRVL 6.5' BCKFLL, CMPCT IN 6" LFTS FRAME 10 TANG ASSY (12V101) OLD 6 FRAME 10 DDE ASSY (12V111) POLE XFR OH SVCS INSTL 10' STILT ARM (10504) FACING S 1' XFR LUMINAIRE # SL-109513-A EDGE OF PAVEMENT ALDER ST WAI NI IT .9 v 991 1050 23, SNOHOMISH COUNTY pLWo 2 rJ PUBLIC Ui1L1iY OISiRICi NO 1 F F65 OPEN LOCATION 915 MAPLE ST. EDMONDS AREA LYNNWOOD POLE No MULTIPLE SE 1/4S 24 T 27 R 3 DATE 5/3/2022 ORDER 100085762 50 75 50 REASON FOR WORK REPLACE it BO POLES ENGINEER BEN ICE OPERATION 0030 OIN EDMONDS DRAFTER UGND No APPROVED SCALE NOTED & DATE 25 50 37 PRINTED F100 15 37 25 15 37 DATE WORK COMPLETED FOREMAN SUBSTATION REFER TO SCHEMATICS 37 CIRCUIT NO SCHEMATIC PHASE 1 2 33 FEES REQ�D ❑ YES ■ No 25 F65 PRIMARY OVERHEAD TO FIVE CORNERS CKT 12-1285 ENGINEER BEN ICE ❑ RESIDENTIAL TO WESTGATE 25 15 25 37 PHONE 425 783 4355 ❑ COMMERCIAL CKT 12-404 F40 25 LEo# 25 CELLULAR 425 422 9297 O PRIMARY UNDERGROUND NESC VIOLATIONS 37 ❑ RESIDENTIAL ❑ NO ❑ YES (SEE NOTES) PERMITS (DATE GRANTED) BEFORE F25 25 2 ❑COMMERCIAL BASIC FEE f ❑ TREE TRIM LEU- ❑ STATE ❑ COUNTY q� = q <=> • CITY SECONDARY UNDERGROUND 25 BASIC FEES ❑ EASEMENTS ❑REQUIRED F65 q�= q OPEN E- ■ NOT REQUIRED UNDERGROUND PLAT 15 50 75 BASIC FEES DATE SENT TO R/W 50 ENGINEERING OO t FT @ I = f DATE APPROVED 15 PLAT CONSTRUCTION FOREIGN CONTACTS 25 G FT @ S = i ■ JPN- O 50 F15 25 0 37 37 25 15 STREET LIGHTING ❑JOINT TRENCH FRONTIER & CATV F 100 15 37 t FT @ $= S ❑ JOINT BORE FRONTIER & CATV 25 CROSSINGS G FT@f = f ❑ 25 F65 WORK IN RIGHT OF WAY POLE STENCILING TO FIVE CORNERS ❑ PRIMARY FROM TO 25 15 CKT 12-1285 ❑ SECONADARY TAKE OFF POLE TO WESTGATE CKT 12-404 F40 25 25 25 tFT@f -s PRE-CONSTR REQUIREMENTS MISCELLANEOUS FEES 25 ❑ TREE TRIM ❑PUD LOCATOR 0 VAULT f ❑ BACKHOE ❑ 37 'U - i PERMIT f ❑ ONE CALL DATE F25 25 f No. s STREET LIGHTING ■ YES ❑ NO AFTER f SCHEMATIC I IM&R I AS -BUILT RESPONSIBLE FOR LOCATING "IS NITSOWNER/CONTRACTOR ALL ON SITE UTILITIES. RELOCATION/REVISION TO ANY TOTAL DUFF DATE PAID I IGIS QC1 M&R GIS owT USE C/G & SIDEWALK FORM UTILITIES MAY REQUIRE A SEPERATE PERMIT. RECEIPT- NEW SVCE APPLICATION- LOCATION MAP M PAGE 454 G6 INSPECTIONS REQUIRED CURB I POOLD POLE (D POLE PLI # 980 F.ALK SET 50'CL 1 POLE (PW1050), 1'N 5'E SET DEPTH = 10' USE s/a" GRVL BCKFLL, CMPCT IN 6" LFTS RETAINING FRAME 30 ALLEY ARM TANG ASSY (12F337) DE WALL FRAME 10 EGA TAP ASSY (12V115) FU 100 T FRAME 10 DE ASSY (12V109) FU 15 T XFR OH SVCS AT THIS LOCATION WE ARE SETTING INSTL 12'STLT ARM (LO505) FACING W A TALLER POLE DEEPER, SO WE ARE XFR LUMINAIRE # SL-112794-H NOT CHANGING THE VIEW RESTORE SIDEWALK AFTER STUB REMOVAL ADA CURB RAMP REPLACEMENT REQUIRED OX POLE PLI # 979 SET 50' CL 1 POLE (PW1050), 1' N 5' E CURB POD NEW SET DEPTH = 10' POLE USE 5/a' GRVL BCKFLL, CMPCT IN 6" LFTS O FRAME 30 ALLEY ARM DDE ASSY (12F341) RMV (3) 12 DISCONNECT SWITCHES —6--]RETAINING XFR OH SVCS SIDE WALL RMV INSTL 3?S SECC UG RISER R&S 4R POS REDL OBSOLETE FED 5) WALK RUN 350 KCMIL TPX TO PED L= 45' AT THIS LOCATION WE ARE SETTING TIE SVC TO NEUT FOR NESC CLEARANCE (R1041& R1042) A TALLER POLE DEEPER,SO WE ARE RESTORE SIDEWALK AFTER STUB REMOVAL NOT CHANGING THE VIEW OY POLE PLI # 982 SET 45' CL 2 POLE (PW2045), S N 3' E SET DEPTH = 6.5' USE 5/8" GRVL BCKFLL, CMPCT IN 6" LFTS FENCE LINE FRAME 10 DE ASSY (12V109) A NEW POLE INSTL (1) PRI DG ( & (1) ll AHR, L= 15' E (A (A010U XFR 15 KVA XFMR 15-397834 (12V601) SIDEWALK 0 7 EXT SEC INSTL 10' ST TS 02) ARM 3(IL0504) FACING S OLD POLE XFR LUMINAIRE # SL-130492-A RMV EXIST SEC UG RISER PLANTER STRIP INSTL 3' SEC RISER & 4 POS PED OU705) CURB RUN 350 KCMIL TPX TO PED L= 45' O POLE PLI # 959 SET 45' CL 2 POLE (PW2045), 53' N SE SET DEPTH = 6.5' USE 5/8" GRVL BCKFLL, CMPCT IN 6" LFTS FRAME 10 TANG ASSY (12V101) RMV 25 KVA ON XFMR CURB POLE UTC #----------------- SER# 6' ROW HANG 25 KVA OH XFMR (BA21N, 12V601) LINE UTC # OPD SER# XFR OH SVCS INSTL 3" SEC RISER & 4 POS PED OU705) RUN 350 KCMIL TPX TO PED L= 45' CURB POOLLE D NEW O POLE 6ROW LINE ® POLE 987 OWNER/CONTRACTOR IS RESPONSIBLE FOR SET 45' CL 2 POLE (PW2045), 2' E EROSION CONTROL AND DRAINAGE SET DEPTH = 6.5 USE 5/8" GRVL BCKFLL, CMPCT IN 6" LFTS FRAME 30 TANG ASSY (12F303) RMV 37 KVA OH XFMR UTC# ----------------- SER# ----------------- HANG 25 KVA OH XFMR (BA21N, 12F601) UTC # ------------------ SER# ------------------ XFR OH SVCS EXT SEC SVCS (C0302) RMV EXIST SEC UG RISER INSTL 3 SEC RISER & 4 POS PED (1U705) RUN 350 KCMIL TPX TO PED L= 45' TIE SVC TO NEUT FOR NESC CLEARANCE (R1041& R1042) CURB ® POLE PLI # 991 SET 35'CL 2 POLE (PW2035), IN PLACE SET DEPTH = 5.5' 7, USE 5/8" GRVL BCKFLL, CMPCT IN 6" LFTS INSTL SEC SPOOL (I0101) SIDEWALK XFR EXIST SEC RISER NEW POLE IN PLACE EXTEND SEC RISER TO MEET 40" NESC CLEARANCE FENCELINE ® POLE PLI # 970 SET 50' CL 1 POLE (PW1050), 5' N SET DEPTH = 10' USE 5/8' GRVL BCKFLL, CMPCT IN 6" LFTS FENCELINE FRAME 30'ALLEY ARM DDE ASSY (12F341) RMV 37 KVA OH XFMR NEW POLE UTC # SIDEWALK 7' SER# HANG 25 KVA OH XFMR (BA21N, 12F601) OLD POLE T 1 I UTC # ------------------ CURB SER# XFR OH SVCS XFR SVCE Y-GUY STENCIL # ED-64X RESTORE SIDEWALK AFTER STUB REMOVAL a PUGET SOUND WORK ZONE WQODWAY RECEIVED MAY 04 2022 Applicant shall repair/replace all ENGINEERING DIVISION APPROVED AS NOTED damage to utilities or frontage improvements in City right-of-way CITY OF EDMONDS per city standards that is caused or Jell 06/10/2022 DEVELOPMENT occurs during the permitted project. VV SERVICES DEPARTMENT flonD W20-1 HEAD = 0 0 �n AD W20-4 D = AxEAo 0 � o_ W20-7A O = 0 • • P-- • r N w • J • Q• _aZ — m • • • V FOR USE AT LOCATIONS S, T. & U 'DAD W20-1 Xmx = AHEM O ONE L E W20-4 AHEAD = O P-� o_ W20-7A W O = O • r N w • J _=Z Q . • FOR USE AT LOCATION Y 0 m �Q 0 O ®W20-7A 0 0 OXE LANE i ono W20-4 HEM O 0 *W20-1 0 m a-- 0 o W20-7A O O D �HE AD W20-4 AHEAD O 0 *W20-1 apno W20-1 poPX = xEAD 0 0 DNE LANE W20-4 ROM .= EAD � o W20-7A O - oL 100' 100' 100' AHEAD HEA W20-1 wµ°E°ADOE W20-7A W20-4 511� FOR USE AT LOCATION V PDAD W20-1 xoaX A EAp _ 0 0 ONE LANE W20-4 aoM AHEAo o W20-7A O 0 w > Q H 0 w z Q J 'ono O W20-1 XORx z N AHEM PWD a XMPDME • W20-4 DxE unE - W20-7A O HD aD W20-1 AHE p XORN EAD 10°. ,00' ,00' • � • ®© ••MAPLE ST a iA V u FOR USE AT LOCATIONS Z & AA O O ® W20-7A 0 O Ax`W20-4 EAD 0 0 flw�flx W20-1 EAD I I � STOP IIF i00�11 100 I, � , OXE LANE VOPX aOM EAD AxEAo W20-1 W20-4 CPEDESTRIANS THROUGH WORKONSITET WHEN NECESSARY 0 m =a 0 o W20-7A O O RE L NE xM W20-4 A EAO 0 0 *W20-1 V FOR USE AT LOCATION W fl0D 1120-1 rp A.EAo 0 0 oxE W20-4 AD .PonD EM O W20-7A o r `) �Z=— z • w z Q J 0 z Y a N b W20-4 W20-1 PDAD wMELANE xuPx I ® EAD AHEM I � 100' 100' I • ®® •� ALDER ST a OEXISTING SIGN 0 0 PanD XaRX 4 M W20-1 Q• m •• �< o 0 W20-7A o WWW ONE LANE RRono W20-4 AHEO rjjy OHOA V 4 MXDRO W20-1 V Il EAD FOR USE AT LOCATION AB ENGINEERING DIVISION APPROVED AS NOTED jell (AI410.44z 06/10/2022 vv W20-1 :ax AxEAo O� V u FOR USE AT LOCATION X A-8 W20-1 xEAD 0 O ONE LANE W20-4 AHEAADD o % —PL L W20-7A O o • N•®r �• z. z Q • m • 0 - ®W20-7A RECEIVED o p E LANE j W20-4 H- o MAY 04 2022 /� o VV Il 4 nEM W20-1 CITY OF EDMONDS FOR USE AT DEVELOPMENT LOCATION AC SERVICES DEPARTMENT LrUUI TRAFFIC CONTROL PLAN PROJECT REPLACE 11 UTILITY POLES LOCATION 915 MAPLE ST EDMONDS ENGINEER BEN ICE DATE 5/3/2022 ORDER 100085762 PHONE 425 783 4355 RECEIVED MAY 04 2022 CITY OF EDMONDS Right -of -Way Application #1136922 - WO 100085762 MyBuildingPermit.com CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Applicant First Name Last Name Company Name Moe Nave Snohomish County PUD Number Street Apartment or Suite Number E-mail Address PO Box 1107 jointuse@snopud.com City State Zip Phone Number Extension Everett WA 98206 4257835681 Contractor Company Name Owner Number Street Apartment or Suite Number City State Zip Phone Number Extension State License Number License Expiration Date UBI # E-mail Address Project Location Number Street Floor Number Suite or Room Number 915 MAPLE ST City Zip Code County Parcel Number EDMONDS 98020 00434206903500 Associated Building Permit Number Tenant Name Additional Information (i.e. equipment location or special instructions)_ Work Location Property Owner First Name Last Name or Company Name Brian J\heidi G Pflugrath Number Street Apartment or Suite Number 915 MAPLE ST City State Zip EDMONDS WA 98020 Certification Statement - The applicant states: I certify that I am the owner of this property or the owner's authorized agent. If acting as an authorized agent, I further certify that I have full power and authority to file this application and to perform, on behalf of the owner, all acts required to enable the jurisdiction to process and review such application. I have furnished true and correct information. I will comply with all provisions of law and ordinance governing this type of application. If the scope of work requires a licensed contractor to perform the work, the information will be provided prior to permit issuance. Date Submitted: 5/4/2022 Submitted By: Moe Nave Page 1 of 2 i CITY OF EDMONDS MyBuildingPermit.com Right -of -Way Application #1136922 - WO 100085762 Project Contact Company Name: Snohomish County PUD Name: Benjamin Ice Email: btice@snopud.com Address: PO Box 1107 Phone #: 4257834355 Everett WA 98206 Project Type Utility Purveyor Activity Type Utility Work Scope of Work Disturbance of Surface Project Name: WO 100085762 Replacing 11 old utility poles with new poles of the same height. Poles are being moved as far from the pavement as feasible given the existing property rights. All poles in the sidewalk are Description of moving behind the sidewalk. Work will include necessary tree trimming. Work duration Work: anticipated to take 2 days per location and work will take place during normal work hours, subject to city ordinance. PUD is not removing the old poles. Old pole stub removal and the associated restoration needed after removal is the responsibility of the last communications attacher to transfer off the old poles. Project Details Project Information Job Number WO 100085762 Page 2 of 2