Loading...
BLD2022-0781_Manufacturer_Specifications_and_Installation_Instructions_6.15.2022_12.45.11_PM_2934167Job Name: System Reference: Date: Indoor Unit.MSZ-FS12NA ............................................................................. Outdoor Unit MUZ-FS12NA INDOOR UNIT FEATURES • Slim wall -mounted indoor units provide zone comfort control • Dual Barrier Coating applied to the heat exchanger, vanes and fan to prevent hydrophilic and hydrophobic dirt build-up • Multiple fan speed options: Quiet, Low, Medium, High, Super -high, Auto • 3D i-see Sensor" enables advance features: o Indirect or Direct Airflow for personalized comfort o Absence Detection for energy -saving mode • Double Vane features: o Separates airflow to deliver air across a large area o Simultaneously deliver to air separate sections of a room o Generates more comfortable natural airflow pattern • Multiple control options available: o Back -lit screen handheld remote controller (provided with unit) o kumo cloud° smart device app for remote access o Third -party interface options o Wired or wireless controllers • Triple -action Filtration: Nano Platinum Filter, Deodorizing Filter, & Electrostatic Anti -Allergy Enzyme Filter • Hot -Start Technology: no cold air rush at equipment startup or when restarting after Defrost Cycle • Quiet operation • The outdoor unit powers the indoor unit, and should a power outage occur, the system is automatically restarted when power returns OUTDOOR UNIT FEATURES • INVERTER -driven compressor and LEV provide high efficiency and comfort while using only the energy needed to maintain maximum performance • H2i plusTM performance offers 100% heating capacity at -50 and 70% to 81 % heating capacity at -130 F • Blue Fin anti -corrosion treatment applied to the outdoor unit heat exchanger for increased coil protection and longer life Specifications are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Cooling at 95°F' Maximum Capacity Rated Capacity Minimum Capacity Maximum Power Input BTU/H 13,600 BTU/H 12,000 BTU/H 2,500 W 1,150 870 1.9 0.83 Rated Power Input W Moisture Removal Pints/h Sensible Heat Factor Power Factor % 94.0/94.0 Heating at 47°F' Maximum Capacity BTU/H 21,000 Rated Capacity BTU/H 12,300 Minimum Capacity BTU/H 3,700 Maximum Power Input W 1,980 Rated Power Input W 850 Power Factor % 94.0/94.0 Heating at 17°F3 Maximum Capacity BTU/H 17,410 Rated Capacity BTU/H 8,400 Maximum Power Input W 1,860 Rated Power Input W 610 Heating at 5°F4 Maximum Capacity BTU/H 14,690 Maximum Power Input W 1,780 Heating at -5°FB Maximum Capacity BTU/H 12,300 Heating at -13°F7 Maximum Capacity BTU/H 11,000 Efficiency SEER 26.1 EER' 13.8 HSPF [IV] 12.5 COP at 47°F2 4.24 COP at 17°F at Maximum Capacity3 2.74 COP at 5°F at Maximum Capacity4 2.42 COP at -5°F at Maximum Capacitye 2.24 COP at -13°F at Maximum Capacity' 2.08 ENERGY STAR® Certified Yes Electrical Voltage, Phase, Frequency 208/230, 1, 60 Guaranteed Voltage Range VAC 187 - 253 Voltage: Indoor - Outdoor, S1-S2 VAC 208/230 Voltage: Indoor - Outdoor, S2-S3 V DC 24 Short-circuit Current Rating [SCCR] kA 5 Recommended Fuse/Breaker Size (Oudoor) A 15 Recommended Wire Size [Indoor - Outdoor] AWG 14 Indoor Unit MCA A 1.0 Fan Motor Full Load Amperage A 0.65 Fan Motor Output W 40 Airflow Rate at Cooling, Dry CFM 137-167-221-304-424 Airflow Rate at Cooling, Wet CFM 117-143-190-261-364 Airflow Rate at Heating, Dry CFM 155-226-282-367-454 Sound Pressure Level [Cooling] dB[A] 21-24-29-36-44 Sound Pressure Level [Heating] dB[A] 21-28-32-38-43 Drain Pipe Size In. [mm] 5/8 [15.88] Coating on Heat Exchanger Dual Barrier Coating External Finish Color Munsell 1.0Y 9.2/0.2 Unit Dimensions W x D x H: In. [mm] 36-7/16 x 9-3/16 x 12 (+11/16) [925 x 234 x 305 (+17)] Package Dimensions W x D x H: In. [mm] 39 x 12-1/4 x 15-1/2 [990 x 310 x 400] Unit Weight Lbs. [kg] 29 [13.5] Package Weight Lbs. [kg] 34 [15.4] Indoor Unit Operating Temperature Range Cooling Intake Air Temp [Maximum / Minimum]* °F 90 DB, 73 WB / 67 DB, 57 WB Heating Intake Air Temp [Maximum / Minimum] °F 80 DB / 70 DB NOTES: AHRI Rated Conditions 'Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB (Rated data is determined at a fixed compressor speed) 2Heating at 47°F (Indoor H Outdoor) °F 70 DB, 60 WB H 47 DB, 43 WB 'Heating at 17°F (Indoor H Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB Conditions 'Heating at 5°F (Indoor H Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB 'Heating at -4°F (Indoor H Outdoor) °F 70 DB, 60 WB // -4 DB, -5 WB 'Heating at -5°F (Indoor H Outdoor) °F 70 DB, 60 WB // -5 DB, -6 WB 7Heating at -13°F (Indoor H Outdoor) °F 70 DB, 60 WB // -13 DB, -14 WB *Outdoor Unit Operating Temperature Range (Cooling Air Temp (Maximum / Minimum)): Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. • For P-Series only: » Wind baffles required to operate below 23°F DB in cooling mode. • Cooling -only system with wind baffle: -40°F - 115°F. n Heat pump system with wind baffle: 0°F - 115°F. • Refer to wind baffle documentation for further information. **Outdoor Unit Operating Temperature Range (Cooling Thermal Lock -out / Re -start Temperatures; Heating Thermal Lock -out / Re -start Temperatures): • System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures. SEACOAST PROTECTION (ONLY APPLIES TO P-SERIES -BS MODELS) External Outer Panel: Phosphate coating +Acrylic -Enamel coating Fan Motor Support: Epoxy resin coating (at edge face) • Separator Assembly Valve Bed: Epoxy resin coating (at edge face) Blue Fin treatment is an anti -corrosion treatment that is applied to the condenser coil to protect it against airborne contaminants. Specifications are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Outdoor Unit MCA MOCP A 10.0 A 15 Fan Motor Full Load Amperage A 0.5 55 Fan Motor Output W Airflow Rate CFM 1215/1201 Refrigerant Control LEV Defrost Method Reverse Cycle Coating on Heat Exchanger Blue Fin Coating Sound Pressure Level, Cooling' dB(A) 49 Sound Pressure Level, Heating2 dB(A) 51 Compressor Type Twin Rotary Compressor Model SNB140FQUMT Compressor Rated Load Amps A 9.2 Compressor Locked Rotor Amps A 7.4 Compressor Oil Type // Charge oz. FV50S // 0.35 External Finish Color Munsell 3Y 7.8/1.1 Base Pan Heater Optional Unit Dimensions W x D x H: In. [mm] 31-1/2 x 11-1/4 x 21-5/8 [800 x 285 x 550] Package Dimensions W x D x H: In. [mm] 37 x 15 x 24-1/2 [940 x 380 x 630] Unit Weight Lbs. [kg] 83 [37.5] Package Weight Lbs. [kg] 90 [40.5] Outdoor Unit Operating Temperature Range Cooling Air Temp [Maximum / Minimum]* *F 115 DB / 14 DB Cooling Thermal Lock -out / Re -start Temperatures** °F -4/0 Heating Air Temp [Maximum / Minimum] °F 75 DB, 65 WB / -13 DB, -14 WB Heating Thermal Lock -out / Re -start Temperatures** °F -18 / -14 Refrigerant Type R410A Charge Lbs, oz 2,9 Chargeless Piping Length Ft. [m] 25 [7.5] Additional Refrigerant Charge Per Additional Piping Length oz./Ft. [g/m] 0.216 [20] Piping Gas Pipe Size O.D. [Flared] In.[mm] 3/8 [9.52] Liquid Pipe Size O.D. [Flared] In.[mm] 1/4 [6.35] Maximum Piping Length Ft. [m] 65 [20] Maximum Height Difference Ft. [m] Maximum Number of Bends 40 [12] 10 NOTES: AHRI Rated Conditions 'Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB (Rated data is determined at a fixed compressor speed) 2Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB 'Heating at 17*F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB Conditions °Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB =Heating at -4°F (Indoor // Outdoor) °F 70 DB, 60 WB // -4 DB, -5 WB =Heating at -50F (Indoor // Outdoor) °F 70 DB, 60 WB // -5 DB, -6 WB 7Heating at -13*F (Indoor // Outdoor) °F 70 DB, 60 WB // -13 DB, -14 WB *Outdoor Unit Operating Temperature Range (Cooling Air Temp (Maximum / Minimum)): Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. For P-Series only: • Wind baffles required to operate below 23OF DB in cooling mode. • Cooling -only system with wind baffle: -40°F - 115*F. • Heat pump system with wind baffle: 0°F - 115°F. • Refer to wind baffle documentation for further information. **Outdoor Unit Operating Temperature Range (Cooling Thermal Lock -out / Re -start Temperatures; Heating Thermal Lock -out / Re -start Temperatures): • System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures. SEACOAST PROTECTION (ONLY APPLIES TO P-SERIES -BS MODELS) • External Outer Panel: Phosphate coating +Acrylic -Enamel coating Fan Motor Support: Epoxy resin coating (at edge face) Separator Assembly Valve Bed: Epoxy resin coating (at edge face) • Blue Fin treatment is an anti -corrosion treatment that is applied to the condenser coil to protect it against airborne contaminants. Specifications are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Control Interface CN24 Relay Kit System Control Interface BACnet® and Modbus Interface Thermostat Interface Wireless Interface for kumo cloud® kumo station® for kumo cloud® IT Extender Lockdown bracket for remote controller ❑ CN24RELAY-KIT-CM3 ❑ MAC-3341F-E ❑ PAC-UKPRC001-CN-1 ❑ PAC-US444CN-1 ❑ PAC-USWHS002-WF-2 ❑ PAC-WHS01 HC-E ❑ PAC-WHS011E-E ❑ RCMKP1CB Wired Remote Sensor ❑ M21 EAA307 Remote Sensor Wireless temperature and humitity sensor for kumo cloud® ❑ PAC-USWHS003-TH-1 Simple MA Remote Controllert ❑ PAC-YT53CRAU-J Wired Remote Controller Deluxe Wired MA Remote Controllert ❑ PAR40MAAU Touch MA Controllert ❑ PAR-CT01 MAU-SB Wireless Remote Controller kumo touch' RedLINK' Wireless Controller ❑ MHK2 Blue Diamond Sensor Extension Cable —15 Ft. ❑ C13-103 Blue Diamond Alarm Extension Cable-6.5 Ft. ❑ C13-192 Blue Diamond MultiTank— collection tank for use with multiple pumps ❑ C21-014 Condensate Sauermann Condensate Pump ❑ S130-230 Drain Pan Level Sensor/Control ❑ SS610E Fascia Kit for MicroBlue Pump, mounts the MicroBlue and sensor directly beneath indoor unit ❑ T18-016 Blue Diamond (MicroBlue) Mini Condensate Pump (110/208/230V) up to 18,000 BTU/H ❑ X85-003 (30A/600V/UL) [fits 2" X 4" utility box] - Black ❑ TAZ-MS303 Disconnect Switch (30A/600V/UL) [fits 2" X 4" utility box] - White ❑ TAZ-MS303W Electro Static Anti -allergy Enzyme Filter ❑ MAC-2330FT-E Filter Platinum Deodorizing Filter ❑ MAC-3000FT-E 15' x 1/4" x 15' / 1/2" Lineset (Twin -Tube Insulation) ❑ MLS141212T-15 30' x 1/4" x 30' / 1/2" Lineset (Twin -Tube Insulation) ❑ MLS141212T-30 Lineset 50' x 1/4" x 50' / 1/2" Lineset (Twin -Tube Insulation) ❑ MLS141212T-50 65' x 1/4" x 65' / 1/2" Lineset (Twin -Tube Insulation) ❑ MLS141212T-65 NOTES: tRequires MAC-3341F-E • M-Series EZ FIT® Recessed Ceiling Cassette, Floor -mount and Wall -mount Allows indoor units to connect to an MA Controller: Deluxe MA Remote Controller Simple MA Controller Touch MA Controller *PAC-SF40RM-E (Unable to use with wireless remote controller) M-Series Ceiling Cassette, Ceiling Suspended, Horizontal -ducted and Multi -position Air Handler P-Series Ceiling Cassette, Ceiling Suspended, Horizontal -ducted and Multi -position Air Handler Specifications are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Air Outlet Guide Air Outlet Guide Drain Socket ❑ MAC-881SG Condensate ❑ MAC-871DS M- & P-Series Maintenance Tool Cable Set ❑ M21 EC0397 Control/Service Tool USB/UART Conversion Cable (Required for all laptop connection) Hail Guard 14 Gauge, 4 wire MiniSplit Cable-250 ft. roll 14 Gauge, 4 wire MiniSplit Cable-50 ft. roll 16 Gauge, 4 wire MiniSplit Cable-250 ft. roll ❑ M21 EC1397 Hail Guards ❑ HG-B4 Mini -Split Wire ❑ S144-250 ❑ S144-50 ❑ S164-250 16 Gauge, 4 wire MiniSplit Cable-50 ft. roll ❑ S164-50 Outdoor Unit 3-1/4 inch Mounting Base (Pair) - Plastic ❑ DSD-400P Mounting Pad Condensing Unit Mounting Pad: 16" x 36" x 3" ❑ ULTRILITEI Optional Defrost Heater Optional Defrost Heater ❑ MAC-640BH-U Outdoor Unit Stand —12" High ❑ QSMS1201 M 18" Single Fan Stand ❑ QSMS1801 M Stand 24" Single Fan Stand ❑ QSMS2401 M Condenser Wall Bracket ❑ QSWB2000M-1 Condenser Wall Bracket -Stainless Steel Finish ❑ QSWBSS Specifications are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. 1d n 2-5/8 2-II/I6 (06/09/12 KBTU/H) Insulation 01-1/16 0.D a Liquid line 4114 19-11/16 (Flared connection 4114) Gas line 43/8 16-15/16 (Flared connection 43/8) Drain hose I Insulafion 41-1/8 Connected pari 05/8 O.D (15/18 KBTU/H) Insulation 01-1/16 0.D d Li uid line 01/4 19-11/16 (Flared connection 4114) Gas Tine 0318 16-15/16 (Flared connection 0112) Drain hose Insulafion 01-1/8 Connected parf 45/8 O.D Unit: inch Specifications are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. 15-3/4 Unit: inch REQUIRED SPACE *1 4 in. (100 mm) or more when front and sides of the unit are clear Air in Drain hale 01-21/32 (MUZ-FS06109112NA) n Drain hole^01-5/16 (MUZ-FS06/09112NAH) 0 Air in y L o i—off 0 oN op c V Air our FORM# MSZ-FS12NA-U1 & MUZ-FS12NA-U1 - 202101 JU �g��n' /(�7p V \o e"%) �l e o< A0'10 � 3S \o;e"`hJ *2 When any 2 sides of left, right and rear of the unit are clear Service Liquid refrigerant pipe joint Refrigerant pipe (flared) o 114 N Gas refrigerant pipe joint N (,� Refrigerant pipe (flared) o 3/8 A 1340 Satellite Boulevard Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com ' C EtI OS Intertek Specifications are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.