BLD2022-0810_Manufacturer_Specifications_and_Installation_Instructions_6.21.2022_9.45.56_AM_2944082A
IU
ELECTRICAL DATA
UNIT SIZE - SERIES
(VOLTAGE)
V/PH
OPER VOLTS*
COMPR
FAN
MCA
MAX FUSE** or
CKT BRK AMPS
MAX
MIN
LRA
RLA
FLA
018-A (N)
208/230/1
253
197
56.3
9.0
0.50
11.8
20
024-A (N)
62.9
10.9
0.50
14.1
25
030-A (N)
73.0
14.1
0.70
18.3
30
036-A (N)
77.0
14.1
1.20
18.8
30
048-A (N)
124.0
18.5
1.20
24.3
40
060-A N)
152.5
23.7
1.45
31.1
50
036-A (P)
208/230/3
253
197
71.0
9.0
1 1.20
1 12.5
20
048-A (P)
83.1
13.7
1.20
18.3
30
060-A (P)
j 110.0
15.9
1.45
21.4
35
036-A (E)
460/3
506
414
1 38.0
5.6
0.60
7.6
15
048-A (E)
41.0
6.2
0.60
8.4
15
060-A (E)
52.0
7.1
I 0.80
9.7
1 15
LEGENM.
FLA - Full Load Amps
HACR - Heating, Air Conditioning, Refrigeration
LRA - Locked Rotor Amps
NEC - National Electrical Code
RLA - Rated Load Amps (compressor)
* Permissible limits of the voltage range at which the unit will operate satisfactorily
** Time -Delay fuse.
Complies with 2007 requirements of ASHRAE Standards 90.1
A -WEIGHTED SOUND POWER (dBA)
Unit Size
Standard Typical Octave Band Spectrum (dBA, without tone adjustment)
Rating
(dBA)
125
250
500
1000
2000
4000
8000
18
69
50.5
57.0
59.5
64.5
60.5
53.5
43.0
24
66
50.5
58.5
60.5
59.5
56.5
51.0
41.5
30
68
55.5
59.5
61.5
63.5
60.0
58.0
49.5
36
71
59.5
59.5
62.0
65.5
63.5
62.0
55.0
48
70
57.5
59.5
10
66.0
63.0
60.5
54.5
60
73
60.0
61.5
64.5
67.0
66.0
1 65.5
58.0
NOTE: Tested in accordance with AHRI Standard 270-08 (not listed in AHRI).
A -WEIGHTED SOUND POWER (dBA) WITH ACCESSORY SOUND SHIELD
Unit Size
Standard
Rating
(dBA)
Typical Octave Band Spectrum (dBA, without tone adjustment)
125
250
500
1000
2000
4000
8000
18
68
52.5
58.0
58.5
64.5
59.5
52.5
42.5
24
65
54.5
57.5
59.5
59.0
56.0
50.5
40.5
30
68
55.0
60.0
61.5
62.5
60.0
58.0
49.5
36
71
59.5
59.5
62.5
65.0
63.0
61.5
55.0
48
70
57.5
59.5
63.0
65.0
62.5
60.0
54.0
60
73
61.0
62.0
64.0
67.0
65.5
65.5
57.5
NOTES:
Tested in accordance with AHRI Standard 270-08 (not listed in AHRI).
Accessory sound shield will not accommodate unit sizes 18 and 24.
CHARGING SUBCOOLING (TXV-TYPE EXPANSION DEVICE)
UNIT SIZE -SERIES _ REQUIRED SUBCOOLING ° F CC)
18 12(6.7)
24 12(6.7)
30 12(6.7)
36 8(4.4)
48 12(6.7)
60 10(5.6)
DIMENSIONS - ENGLISH
0
00
UNIT SERIES; ELECTRICAL
_ CHARACTERISTICS
A
B
C
D
E
F
G
H
J
K
L
N
N
OPERATING SHIPPING SHIPPING
P WEIGH_Tllbsl WEIGHT(lbs) DIMENSIONS (L x IN HI
S 13116" 146 I6i 1 4[ 15/16" % 16' % 34 I/8'
124AN so - 0
%I
U
1 0
U
31 1/8"
36 15/16-
14 9/16'
16'
23 7/16"
17 3/16"
23 1/6'
28 1116'
13'
6 5/8•
II 1/4'
518'
2 7/8"
124ANSOZ 0
IT0
0
0
31 If8"
36 15116'
14 9116'
16'
23 7116'
17 3/16"
23 1/8"
28 1116"
U'
6 )14'
II 5/8'
]1/'
2 118'
51
148
168
!2 IS/16" % 18' % 34 118'
124ANS01 0
x
0
0
0
37 118"
44 1 R"
11 1116'
18 f116'
30 112'
19 518'
29 I18'
34 1/16"
13 11/16'
8 I/8'
15 7/8"
3l4"
S )!8'
6 3f 8'
783
213
50 1f2' % 20 1J 2' % 10 If8'
124AN503 0
%
0
%
x
37 118"
44 1/2•
ll 1/16'
18 1/16"
30 112"
19 5f8'
?9 V8'
J4 171b'
1) IIf16'
8 1/8'
15 718'
118"
3 3/8'1/8'
124ANS04 0
X
0
x
%
31 115'
44 111'
17 1116'
18 1/16"
30 I!2"
19 5/e'
29 I/8"
J4 1116'
11 112'
8 1!2'
18 )/8'
T78'
3 3f8'
6 3/5"
213
243
50
112' I 20 112' % 40 I18'
2/ANS06 0
%
0
%
X
/! 118'
d/ If2'
If 1l16'
18 1116'
JO 1!2'
19 516'
!S I/6'
/0 1l14'
14 ll2'
8 1/2'
18 1/8"
118'
) S!8'
6 J18'
2/5
215
50 1/2' % 70 1/2' % 16 118'
O
�
bO
y
Qc�
x = YES
m
c+l
0 = NO
m
N
N
W
O
N
N
MINIMUM
UNIT SIZE MOUNTING PAD
DIMENSIONS
18. Z4 23" X 42"
30, 36,48,60 2/' x 50"
AIR
FIELD CONTROL SUPPL9
WIRE ENTRY
718" HOLE W/GROMMET
M VAPOR LINE CONN
/ FEMALE SWEAT CONN.
L
�--0 315" LIQUID LINE
FEMALE SWEAT CONN I
1 CLEARANCE REQUIREMENTS' STNGLC UNIT APPLICATIONS' WITH COIL FACING WALL' ALLOW 6 IN MINIMUM CLEARANCE
ON COIL SIDE AND COIL END AND 20 IN MINIMUM CLEARANCE ON FAN SIDE WITH FAN FACING WALL' ALLOW 8 IN
MINIMUM CLEARANCE ON FAN SIDE AND 6 IN OH COIL ENU AND 20 IN MINIMUM CLEARANCE ON COIL SIDE
MULII-UNIT APPLICATIONS! ALLOW 24 IN. MINIMUM CLEARANCE BETWEEN FAN AND COIL SIDLS OF MULTIPLE UNITS
ARRANGE UNITS SO DISCHARGE OF ONE DOES NOT ENTER INLET OF ANOTHER.WHEN TWO UNITS ARE INSTALLED END TO END
WIIH THE COIL ENDS FACING EACH OTHER ALLOW 12 IN MINIMUM CLEARANCE BETWEEN UNITS
C UMPRESSON END
SERVICE CLEARANCE' ALLOW 24 IN MINIMUM CLEARANCE ON COMPRES50k ENU WHEN UNITS AAE STACKED OR
IHLRE 1S LESS THAN 40 IN. OF CLEARANCE ABOVE THE TOP OF THE UNIT. IF THERE IS 40 1N CLEARANCE ABOVE UNIT AND
THE TOP PANEL 15 ACCESSIBLE FOR REMOVAL ALLOW B IN. MINIMUM CLEARANCE ON COMPRESSOR IND FOR SERVICE
IMPORTANT: WHEN INSTALLING SINGLE OR MULTIFEE UNIT', 1N AN "'0"' ROOF WELL, OA 11RIIALLY ENCLOSED AREA,
EN:;URE IHERE I5 ADEBUATE VENTILATION TO PREVENI HE RC UL ATION OF )[`CHARGE AIR,
'2. MINIMUM OUT D00R OPERATING AMBIENT IN CODLING
112' MODE Ll` 55`F, MAX 125"F:
3. SERIES DESIGNATION IS THE 13TH POSITION OF THE
UNIT MODEL NUMBER.
4. CENTER OF GRAVITY
4 3116" 5. ALL DIMENSIONS ARE IN "INCHES" UNLESS NOTED.
3UN(IION BOX FOR
k,& SUPLL7 AND
CONTROL CONNECTIONS
1 1116'
J+
7/16' I
G
IiIELD POWER SUPPLY CONN.
HOLI SIZES PHOVIDED:
0 1/0" HOLE WIH
0 1 1/8" KNOCKOUT AND
0 13/3" KNOCKOUI