Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BLD2022-0806_Other_6.21.2022_9.05.59_PM_2946457
Job Name: System Reference: Date: w FEATURES • Compatible with M- and P-Series and CITY MULTI indoor units. Branch box required for connection with M- and P-Series • Variable speed INVERTER -driven compressor • Seacoast protection on heat exchanger and base panel (rated for 2,000 hrs in accordance with ASTM B117 testing) • Thermal Differential 1 °F (with PAC-MKA32/52BC only) • Built-in base pan heater • Quiet outdoor unit operation, rated sound pressure as low as 50 dB(A) • High pressure protection • Compressor thermal protection • Compressor overcurrent detection • Fan motor overheating/voltage protection • Hyper -heating performance offers 100% heating capacity at 5°F and 75% heating capacity at -13°F ENERGY STAR products are third -party certified by an EPA -recognized Certification Body. Specifications are subject to change without notice. © 2022 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Cooling' (Non -Ducted // Mix // Ducted) Maximum Capacity Rated Capacity BTU/H 42,000 H 42,000 // 42,000 BTU/H BTU/H 42,000 H 42,000 // 42,000 15,500 H 15,500 H 15,500 Minimum Capacity Maximum Power Input W W % 3,135 H 3,440 // 3,820 3,135 H 3,440 // 3,820 98.5, 98.5 H 98.5, 98.5 H 98.5, 98.5 Rated Power Input Power Factor (208V, 230V) Heating at 47°F2 (Non -Ducted H Mix H Ducted) Maximum Capacity BTU/H BTU/H 48,000 H 48,000 H 48,000 48,000 H 48,000 H 48,000 Rated Capacity Minimum Capacity BTU/H 24,000 H 24,000 H 24,000 Maximum Power Input W 3,430 H 3,750 // 4,140 Rated Power Input W 3,430 H 3,750 // 4,140 Power Factor (208V, 230V) % 98.5, 98.5 H 98.5, 98.5 H 98.5, 98.5 Heating at 17°F3 (Non -Ducted H Mix // Ducted) Maximum Capacity BTU/H 48,000 H 48,000 H 48,000 Rated Capacity BTU/H 32,000 H 32,000 // 32,000 Maximum Power Input W 6,110 H 6,900 H 3,135 Rated Power Input W 3,350 H 3,550 // 3,750 Heating at 5°F4 (Non -Ducted // Mix H Ducted) Maximum Capacity BTU/H 48,000 H 48,000 H 48,000 Maximum Power Input W 7,030 H 7,215 H 7,405 Efficiency (Non -Ducted H Mix // Ducted) SEER 22.0 H 20.0 H 18.0 EER' 13.4 H 12.2 H 11.0 HSPF (IV) 12.0 H 11.5 H 11.0 COP at 47°F2 4.1 // 3.75 H 3.4 COP at 17°F at Maximum Capacity3 2.3 H 2.0 H 1.9 COP at 5°F at Maximum Capacity' 2.0 H 1.95 H 1.9 ENERGY STAR® Certified Yes H No H No Electrical Voltage, Phase, Frequency 208/230, 1, 60 Guaranteed Voltage Range VAC 187-253 Voltage: Indoor - Outdoor, S1-S2 VAC 208/230 Voltage: Indoor - Outdoor, S2-S3 V DC 24 Short-circuit Current Rating (SCCR) kA 5 Recommended Fuse/Breaker Size if Branch Box Powered by Outdoor Unit A 45 Recommended Fuse/Breaker Size without Branch Box or Branch Box Powered Separate A 40 Recommended Wire Size (Indoor- Outdoor) AWG 16 MCA if Branch Box Powered by Outdoor Unit A 42.0 MCA without Branch Box or Branch Box Powered Separate A 36 MOCP if Branch Box Powered by Outdoor Unit A 50 MOCP without Branch Box or Branch Box Powered Separate A 40 Fan Motor Full Load Amperage A 0.6+0.6 Fan Motor Output W 74 Outdoor unit Airflow Rate (Cooling / Heating) CFM 3,885 / 3,885 Refrigerant Control LEV Defrost Method Reverse Cycle Heat Exchanger Type Plate fin coil Heat Exchanger Coating Blue Fin Coating Sound Pressure Level,Cooling' dB(A) 50 Sound Pressure Level,Heating' dB(A) 54 Compressor Type Hermetic Compressor Model ANB33FJSMT Compressor Motor Output kW 2.9 Compressor Rated Load Amps A 19 Compressor Locked Rotor Amps A 22.0 Compressor Oil Type H Charge oz. FV50S H 73 Base Pan Heater Built-in Unit Dimensions W: In. [mm] 41-11/32[1,050] D: In. [mm] 13[330] H:In. [mm] 52-11/16[1,338] Package Dimensions W: In. [mm] 43 [1,090] D: In. [mm] 18 [450] H: In. [mm] 57 [1,430] Unit Weight Lbs.[kg] 278 [126] Package Weight Lbs.[kg] 302 [137] NOTES: AHRI Rated Conditions 'Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB (Rated data is determined at a fixed compressor speed) 21-leating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB 3Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB Conditions 41-leating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB "Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. when 1 or more PIA-A-EA7 connected 'a Branch box should be placed within the level between the outdoor unit and indoor units 5°F DB - 115°F DB when optional wind baffles are installed For actual capacity performance based on indoor unit type and number of indoor units connected, please refer to MXZ Operational Performance. Although the maximum connectable capacity is 130%, the outdoor unit cannot provide more than 100% of the rated capacity. Please utilize this over capacity capability for load shedding or applications where it is known that all connected units will NOT be operating at the same time. Specifications are subject to change without notice. © 2022 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Outdoor unit operating temperature range Cooling Intake Air Temp (Maximum / Minimum) °FDB 115 / 23 Cooling Thermal Lock -out / Re -start Temperatures °FDB N/A/ N/A Heating Intake Air Temp (Maximum / Minimum) °FWB 59 / -13 Heating Thermal Lock -out / Re -start Temperatures °FDB -24 / -14 Refrigerant Type R410A Charge Lbs, oz 10, 9.0 Indoor unit connection Maximum Number of Connected IDU with Branch Box 5 (4)1 Maximum Number of Connected IDU without Branch Box 12 Minimum Number of Connected IDU with Branch Box 2 Minimum Number of Connected IDU without Branch Box 1 Minimum Connected Capacity with Branch Box BTU/H 12,000 Maximum Connected Capacity BTU/H 54,000 Piping Liquid Pipe Size O.D. (Flared) In.[mm] 3/8 [9.52] Gas Pipe Size O.D. (Flared) In.[mm] 5/8 [15.881 Total Piping Length when using Branch Box Ft. [m] 492 [150] Total Piping Length without Branch Box Ft. [m] 984 [ 300] Maximum Height Difference's, ODU above IDU Ft. [m] 164 [50] Maximum Height Difference'B, ODU below IDU Ft. [m] 131 [40] Maximum Height Difference's, between branch boxes Ft. [m] 49 [15] Maximum Height Difference'B, between branch boxes and IDU Ft. [m] 49 [15] Maximum Height Difference between IDU and IDU without branch box Ft. [m] 49 [15] Max. Piping Length between ODU and Branch Box Ft. [m] 180 [55] Farthest Piping Length from ODU to IDU with Branch Box Ft. [m] 262 [80] Farthest Piping Length from ODU to IDU without Branch Box Ft. [m] 492 [150] Farthest Piping Length after Branch Box Ft. [m] 82 [25] Total Piping Length between Branch Boxes and IDU Ft. [m] 311 [95] Maximum Number of Bends for IDU 15 NOTES: AHRI Rated Conditions 'Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB (Rated data is determined at a fixed compressor speed) 2Heating at 47°F (Indoor H Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB 'Heating at 17°F (Indoor H Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB Conditions °Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB 'Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. when 1 or more PIA-A-EA7 connected 'B Branch box should be placed within the level between the outdoor unit and indoor units 5°F DB - 115°F DB when optional wind baffles are installed For actual capacity performance based on indoor unit type and number of indoor units connected, please refer to MXZ Operational Performance. Although the maximum connectable capacity is 130 % , the outdoor unit cannot provide more than 100 % of the rated capacity. Please utilize this over capacity capability for load shedding or applications where it is known that all connected units will NOT be operating at the same time. Specifications are subject to change without notice. © 2022 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Air Deflector Vertical Air Deflector Air Outlet Guide (1 Piece) Refrigeration Ball Valve - 1/2" Refrigeration Ball Valve - 1/4" Refrigeration Ball Valve - 3/8" ❑ ADV-1 Air Outlet Guide ❑ PAC-SH96SG-E (two pieces are required) Ball Valve ❑ BV12FFSI2 ❑ BV14FFSI2 ❑ BV38FFSI2 Refrigeration Ball Valve - 5/8" ❑ BV58FFSI2 Branch Box ❑ PAC-MKA32BC Branch Box Branch Box ❑ PAC-MKA52BC Branch Box Enclosure ❑ BBE-1 Centralized Drain Pan Central Drain Pan ❑ PAC-SH97DP-E M-Net Control Wire, 1,000' Roll (16-AWG, Standard, Twisted Pair, Shielded, Jacketed- Plenum rated) ❑ CW162S-1000 Control Wire M-Net Control Wire, 250' Roll (16-AWG, Standard, Twisted Pair, Shielded, Jacketed- Plenum rated) ❑ CW162S-250 Control/Service Tool Maintenance Tool Interface ❑ PAC-USCMS-MN-1 Brazed Connection ❑ MSDD-50BR-E Distribution pipe Flare Connection ❑ MSDD-50AR-E Hail Guards Hail Guard ❑ HG-A2 14 Gauge, 4 wire MiniSplit Cable-250 ft. roll ❑ S144-250 14 Gauge, 4 wire MiniSplit Cable-50 ft. roll ❑ S144-50 Mini -Split Wire 16 Gauge, 4 wire MiniSplit Cable-250 ft. roll ❑ S164-250 16 Gauge, 4 wire MiniSplit Cable-50 ft. roll ❑ S164-50 Mounting Pad Outdoor Unit 3-1/4 inch Mounting Base (Pair) - Plastic ❑ DSD-400P Adaptor: 1/2" x 3/8" ❑ MAC-A455JP-E Adaptor: 1/2" x 5/8" ❑ MAC-A456JP-E Port Adapter Adaptor: 3/8" x 1/2" ❑ MAC-A454JP-E Adaptor: 3/8" x 5/8" ❑ PAC-SG76RJ-E 18" Dual Fan Stand ❑ QSMS1802M 24" Dual Fan Stand ❑ QSMS2402M Stand Condenser Wall Bracket ❑ QSWB2000M-1 Condenser Wall Bracket - Stainless Steel Finish ❑ QSWBSS Outdoor Unit Stand —12" High ❑ QSMS1202M Wind Baffle Front Wind Baffle ❑ WB-PA3 (two pieces are required) Specifications are subject to change without notice. © 2022 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. I FREE SPACE(Around the unit) TRe EM bp—w abavaeranPk. ErplereW. Wndperlirulerr Aegisae phenintlrtirebMtion nenuaMdc. 1 •••Rd ,MWplcemnreepoalFI4AE10A 2 ••• RS*IWUDUIDOp lwAd (MRE) 09,U(MRN '1 --dSTOPMEmnreGba lawpon. Piping Knock Out Hole Details 3 FOUNDATION BOLTS 4 PIPING -WIRING DIRECTIONS PbafeswretleunilRmly PpipatlxibAmnnaaporw wMAlwnAepm M10�WYS+IhoA aabematlerWm Gions: (BGL aMwaakrsmuGhe Fmd,W¢p, ReaaM BeWx. puMasei baalN) MXZ-SM36NAMHZ MXZ-SM42NAMHZ 15.88 (5/8F) 426 <16-25/32> 485 <19-3/32> MXZSM48MAMHZ MXZ-SM60NAM 19.05 (3/4F) 393 <15-15/32> 450 <17-23/32> MXZ-SM36MAM 15.88(5/81F) 426 <16-25/32> 485 <19-3/32> MXZSM48NAM MODEL NAME DIMENSION A DIMENSION 13 DIMENSION C C A 3