APPROVED FIR FIR2021-0117+Fire_Sprinkler_Plan+11.2.2021_2.00.42_PM+2497270A B C D I I I 9 I 8 co M CD 0 I q T-6" T-11 7/16" 13'-11 9/16" 2'-8" _ I 68'-5 1/2" T-11 1/2" DRY'R BEDROOM 5 120CFM q � i _ CONNECT T WATER CLU ET SUPPLY. I I N 3/4 80 CFM 1_0 BATHV.T.O I I i I I I N 5 M � q CID _ 4'-0" T-15" BED 00M 4 4 RECREATION RM. I J I I I 1 ALERT FOR CONTRACTORS ALL TRA ,S: 6'-111/2" THIS PROJECT USES BLAZEMASTER PIPE & FITTINGS THAT ARE SPECIFICALLY FOR FIRE SPRINKLER SYSTEMS. THEY ARE MADE FROM A SPECIALTY THERMO PLASTIC KNOWN AS POST CHLORINATED POLYVINYL CHLORIDE. (CPVC) DO NOT USE OR PLACE IN CONTACT ANY MATERIAL THAT ARE INCOMPATIBLE WITH CPVC SUCH AS PETROLEUM OR SOLVENT BASED SEALANT, FIRE STOP INSULATION, ETC. PLEASE REFER TO LUBRIZOL FBC SYSTEM COMPATIBILITY PROGRAM FOR GUIDANCE REGARDING CHEMICAL COMPATIBILITY OF CERTAIN MATERIALS GO TO BLAZEMASTER.COM iF� O i V.T.O. WHOLE HOUSE FAN w1 TIMER UWASFHF'R LAUNDRY 8-0 1-4 1, FIRE SPRINKLERS ARE NOT it REQUIRED IN CRAWL SPACES PER NFPA 13D. THRU WALL ACCESS TO CRAWLSPACE CRAWLSPACE E F G I 32'-5" 0'-5 1/2" FIRE SPRINKLER GAS HOT WATER RISER LOCATION SYSTEM (1.51E.C. TOR SEE RISER DET. 1' 10-0 o` 1-51/ti loo 3-4 W o GASFURNACE v o Drain to be terminated MECH. ROOM outside. Basement. I/ 11�11_011 a � BAR SINK I I _I- dw IX U LL Q wCL Of 07 Floo --- -- STORAGE UNDER STAIRS. 1/2" GWB. UP Q Z Q I I I I I I I I I I I I I I I N W I I I I I I 1.Approved set of plans must be on site at the time of inspection. Failure to provide the approved set may result in a re -inspection fee. System drain(s) required at riser and must drain to the exterior. If riser is above lowest grade, 2nd drain required and signage at riser indicating location. Systems require signage IAW NFPA 13D. 2.Coverage required to the following areas: Clothes closets, linen closets and pantries exceeding 24 square feet in area, with the smallest dimension greater the 3' and having wall and ceiling surfaces of gypsum board. Bathrooms more than 55 square feet in area. When fuel fired equipment is present on covered decks or porches, or if living space above, at least one quick -response intermediate temperature sprinkler shall be installed above the equipment or area under living space. All fuel fired appliances, except attics if above all living areas. 3.Residential 13R add: Vertical back flow preventer must be tested annually. Strongly recommend system be monitored by fire GENERAL NOTES: 1 THIS SYSTEM IS DESIGNED PER SPRINKLER MANUFACTURER'S LISTING. SEE ATTACHED CUT SHEETS FOR MANUFACTURER'S MIN. REQUIREMENTS. A TOTAL OF (2) HEADS OPERATING USING RESIDENTIAL, CONCEALED. 2 INSTALLATION TO CONFORM WITH NFPA #13D & EDMONDS FIRE DEPT. 3 ALL MATERIAL TO BE NEW, U.L. LISTED, AND PER NFPA #13. 4 ALL FITTINGS TO BE CPVC U.N.O. 5 ALL PIPE TO BE CPVC U.N.O. NFPA 13 D 6 PROTECTION OF HEADS FROM PAINT BY OTHERS. 7 . ALL ELECTRICAL WIRING BY OTHERS. HYDRAULIC CALCULATIONS ARE BASED ON TWO SPRINKLER HEADS SPACED AT 16'x16' MAXIMUM. 90 ELBOW rOR PTO SYSTEM PRESSURE GAUGE SPARE HEAD CABINET W/ HEADS & WRENCH Q LO W C (OPTIONAL) No Bell Required Drain valve TO DOMESTIC NOR -TECH WORK BEGINS CONTROL VALVE BOR 1 RISER RM FINISH FLOOR Maximum Water pressure 80 psi SIPPLY Flow-Thru Riser Detail A 112' OUTLET WITH POINT OF CONNECTION FOR DOMESTIC SUPPLY TO 112' POTABLE PLUG WATER CLOSET/LAVATORY. POC TO BE LEFT WITH 1/2 AT 6 FT, A,F,F, POTABLE PLUG TO BE REMOVED BY PLUMBER TO MAKE CONNECTION AFTER HYDROSTATIC TESTING & NOR -TECH TO PIPE ROUGH -IN INSPECTED WITH FIRE MARSHAL. PLUMBER DOWN TO 6'-0' A.F.F. TO USE ONLY CPVC COMPATIBLE CONNECTION. DO NOT WITH 112' OUTLET & OVER TIGHTEN. 112' POTABLE PLUG � I N �1112' WATER LINE r Plan I I 1 " WATER wN0 I METER Approved PROPERTY LINE DFM Chr%s gust wril South County Fire Date: 11 /03/2021 1" COPPER PUBLIC MAIN CC 11-03-2021 PLAN REVIEW Approved with condition: 1. System must drain to exterior. DFM Burt CONDITION: System must drain to the exterior. FIR2021-0117 RECEIVED Nov 02 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT �r�rrrrrrrrrrrr��rrrrrrrrrrrrR i wASI Mu"w! WAVE ; OLRTIFIoATE aF oaerP+r FIRE M W 11112QTIt11! Sr UIN KL}7l SIVOTEltli Khosrow (David) Farahani T_ a 7325-0195-C Lavel 3 N E Nor -Tech Fire Protection, Inc. N R NORTEFPa51P6 !so -?AA11=11-1 attx� iRAilli �.. _ a WATER FLOW INFORMATION: STATIC: 105 PSI WATER DEPARTMENT JURISDICTION: EDMONDS HANGER LEGEND STANDARD SYMBOLS SPRINKLER HEAD SYMBOLS MK DATE BY REVISIONS - LOCATE BY GRID COORDINATES FIELD INSPECTION BY PHONE CONTRACT WITH xxx NORTH PROJECT Wardak Residence ADDRESS: 541 12th Ave North CITY Edmonds, WA 98020 SPRINKLERS SYMB. MODEL ID # THREAD "K" FINISH ESCUTCH. TYPE DEGREE QTY. 1.Edmonds Fire Dept. xx 2 xxxx VIKING RESIDENTIAL SPRINKLER ® VK494 20759 1 /z' 4,9 BRASS WHITE CONC. 200° 14 . 3. CITY 4. 123 TITLE: FIRE SPRINKLER PLAN WATER DEPT. ARCHITECThe Leren Company ®- ® NOR -TECH FIRE PROTECTION INC. DESIGNED: D.F. DATE: 11 /2/21 21 TRACT # 5 20030 NE Novelty Hill Road -Box B REDMOND, WASHINGTON 98053 425-898-9111 FAX: 425-898-7772 LICENSE NO. NORTEFP051P6 ADDRESS P.O. Box 12863 CITY CITY Mill Creek, WA 98082 SHEEP N0. FP-1 of 2 TOTAL SPRINKLERS THIS DRAWING 14 PHONE PHONE 206-954-4145 SCALE: 1/4"=1'-0" Composite Wood Joist \ NB-1 Headset Mounting Bracket and No Block Hanger Offset Hanger Headset Gyp. Board Ceiling CPVC HANGER DETAIL "A" Wood Joist NB-2 Headset Mounting Bracket and No Block Hanger Offset Hanger c z c Headset / Gyp. Board Ceiling CPVC HANGER DETAIL "B" ATTIC FIRE SPRINKLER PIPE (ON WARM SIDE OF INSULATION). (D4 /_ INSULATION (:: 3 TRUSS AND GYPSUM WALL BOARD CEILING SPRINKLER PPE IN THE ATTIC NO SCALE HYDRAULIC CALCULATIONS ARE BASED ON TWO SPRINKLER HEADS SPACED AT 16'x16' MAXIMUM. ALERT FOR CONTRACTORS &ALL TRADE... THIS PROJECT USES BLAZEMASTER PIPE & FITTINGS THAT ARE SPECIFICALLY FOR FIRE SPRINKLER SYSTEMS. THEY ARE MADE FROM A SPECIALTY THERMO PLASTIC KNOWN AS POST CHLORINATED POLYVINYL CHLORIDE. (CPVC) DO NOT USE OR PLACE IN CONTACT ANY MATERIAL THAT ARE INCOMPATIBLE WITH CPVC SUCH AS PETROLEUM OR SOLVENT BASED SEALANT, FIRE STOP INSULATION, ETC. PLEASE REFER TO LUBRIZOL FBC SYSTEM COMPATIBILITY PROGRAM FOR GUIDANCE REGARDING CHEMICAL COMPATIBILITY OF CERTAIN MATERIALS GO TO BLAZEMASTER.COM Main Floor Plan NO. OF SPRINKLERS CALCULATED: COVERAGE PER SPRINKLER: 16'x16' DESIGN DENSITY: 10.05 GPM & or per MFG listing N TOTAL AREA OF DISCHARGE: 512 SF. MIN. GPM REQUIRED PER HEAD: 13 GPM TOTAL SPRINK DEMAND AT B.O.R. 26.4 GPM @ 35.7 PSI AVAILABLE AT THE B.O.R. 126.4 GPM @ 93.2 PSI �rrrrrrrrrrrrrrrrrrrrrrrrrrrrR WAMI1111me lMl a'ra" elRTIFIOAT@ nF coupe IBOV FIRE 110111111101111201 4 WRIMKLER •TSTEP Khosrow (David) Farahani N f 7325-0195-C Luvel3 N a Nor -Tech Fire Protection, Inc, N e NORTEFP051PS o !in • 14Ri7li �� WATER FLOW INFORMATION: STATIC: 105 PSI WATER DEPARTMENT JURISDICTION: EDMONDS HANGER LEGEND STANDARD SYMBOLS SPRINKLER HEAD SYMBOLS MK DATE BY REVISIONS — LOCATE BY GRID COORDINATES FIELD INSPECTION BY PHONE CONTRACT WITH O'Dell Homes NORTH PROJECT Wardak Residence ADDRESS: 541 12th Ave North CITY Edmonds, WA 98020 SPRINKLERS SYMB. MODEL ID # THREAD "K" FINISH ESCUTCH. TYPE DEGREE QTY. 1.Edmonds Fire Dept. xx 2. xxxx VIKING RESIDENTIAL SPRINKLER ® VK494 20759 1 /z' 4,9 BRASS WHITE CONC. 200° 24 3. CITY 4. 123 TITLE: FIRE SPRINKLER PLAN WATER DEPT. ARCHITECThe Leren Company ® _ ® NOR —TECH FIRE PROTECTION INC. DESIGNED: D.F. DATE: 11 /2/21 21 TRACT # 5 20030 NE Novelty Hill Road —Box B REDMOND, WASHINGTON 98053 425-898-9111 FAX: 425-898-7772 LICENSE NO. NORTEFP051P6 ADDRESS P.O. Box 12863 CITY CITY Mill Creek, WA 98082 SHEEP N0. FP-2 of 2 TOTAL SPRINKLERS THIS DRAWING 24V\I PHONE PHONE 206-954-4145 SCALE: 1/4"=1'-0"