REVIEWED FIR FIR2021-0117+Equipement+10.22.2021ES-A-2000B Series 2000B Double Check Valve Assemblies Sizes: 1/2" — 2" (15 — 50mm) Features • Ease of maintenance with only one cover • Top entry • Replaceable seats and seat discs • Modular construction • Compact design • 1/2" — 2" (15 — 50mm) Cast bronze body construction • Top mounted ball valve test cocks • Low pressure drop • No special tools required • 1/2" — 1 " (15 — 25 mm) have tee handles Available Models Suffix: B - Quarter turn ball valves LBV - less ball valves SH - stainless steel ball valve handles HC - 2'/2" inlet/outlet fire hydrant fitting (2" valve) Pressure — Temperature Temperature Range: 33°F — 140°F (0.5°C — 60°C) Maximum Working Pressure: 175psi (12.1 bar) Standards AWWA Std. C510, IAPMO PS31 Job Name Job Location Engineer Approval A A M E S FIRE & WATERWORKS C.. I 2" 2000B HC (50mm) % so, &W W 2000B (20mm) Series 2000B Double Check Valve Assemblies shall be installed at referenced cross - connections to prevent the backflow of polluted water into the potable water supply. Only those cross -connections identified by local inspection authorities as non -health hazard shall be allowed the use of an approved double check valve assembly. Check with local authority having jurisdiction regarding vertical orientation, frequency of testing or other installation requirements. These valves meet the requirements of ASSE Std. 1015 and AWWA Std. C510 and are approved by the Foundation for Cross -Connection Control and Hydraulic Research at the University of Southern California. Specifications A Double Check Valve Assembly shall be installed at each noted location. The assembly shall consist of two positive seating check modules with captured springs and rubber seat discs. The check module seats and seat discs shall be replaceable. Service of all internal components shall be through a single access cover secured with stainless steel bolts. The assembly shall also include two resilient seated isolation valves and four top mounted, resilient seated test cocks. The assembly shall meet the requirements of ASSE Std. 1015 and AWWA Std. C510. Approved by the Foundation for Cross -Connection Control and Hydraulic Research at the University of Southern California. Assembly shall be an Ames Company Series 2000B. Approvals Assif", H55E ��® N C Q. US c us 1015 B64.5 (LBV Models Only) Approved by the Foundation for Cross -Connection Control and Hydraulic Research at the University of Southern California. LBV models not listed. Horizontal and vertical "flow up" approval on all sizes. Contractor Approval Contractor's P.O. No. Representative Ames product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please contact Ames Technical Service. Ames reserves the right to change or modify product design, construction, specifications, or materials without prior notice and without incurring any obligation to make such changes and modifications on Ames products previously or subsequently sold. www.amesfirewater.com Dimensions - Weights Suffix HC - Fire Hydrant Fittings dimension "A" = 23'/2" (594mm) (ON) DIMENSIONSSIZE in. mm A in. mm in. B mm C in. mm F in. mm G in. mm H in. mm in. I mm lbs. kgs. '/2 15 10 254 4% 117 2'/16 62 5 127 3% 85 26/16 59 2'/16 52 4.5 2 3/4 20 11 % 282 4 102 3'/s 79 63/ 6 157 V16 87 2% 54 16/ 6 33 5 2.3 1 25 13'/4 337 1 51/8 130 1 4 102 1 7'/2 191 1 3% 85 11'/6 43 111/6 43 1 12 5.4 1'/4 32 16% 416 5 127 36/6 84 91h 241 5 127 3 76 2 50 15 6.8 11/2 40 163/4 425 4'/8 124 31h 89 93/4 248 51Y16 148 3'/s 79 2"/6 68 15.86 7.2 2 50 19'/2 495 6'/4 159 4 102 13% 340 6'/8 156 37/6 87 2"/16 68 25.75 11.7 Strainer sold separately Capacities As compiled from documented Foundation for Cross -Connection Control and Hydraulic Research at the University of Southern California lab tests. ATypical maximum system flow rate (7.5 feet/sec., 2.3 meters/sec.) kPa psi 112" (15mm) y 83 12 0 69 10 m 55 8 41 6 N 28 4 aNi 14 2 a 0 0 0 2 4 6 8 10 12 gpm AP 0 7.6 15.2 22.8 30.4 38 45.6 Ipm 5 7.5 10 fps 1.5 2.3 3.0 mps Flow Rate ��■ ����■ IIIIIIIIIIIII■IIIIIIIIIIIII■■ IIIII■IIIIIIIIIIIII■IIIIIIIIIIIII■IIIIIIIIIIIII■■ IIIIIIIIIIIII■IIIIIIIIIIIII■■ IIIII■IIIIIIIIIIIII■IIIIIIIIIIIII■IIIIIIIIIIIII■■ 69 1 ��■ ����■ IIIIIIIIIIIII■IIIIIIIIIIIII■■ IIIII■IIIIIIIIIIIII■IIIIIIIIIIIII■IIIIIIIIII�� 41 ��■ ����■ 14 ;ice■ ����■ kPa psi 11/4 ° (32MM) 96 14 A 83 12 N o 69 10 y 55 8 7 41 6 d 28 4 14 2 a- 0 0 AP 0 10 20 30 40 50 60 70 80 90 100 110 120 gpm 0 38 76 114 152 190 228 266 304 342 380 418 456 Ipm 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps Flow Rate kPa psi 83 12 H 69 10 0 55 8 0 41 6 3 28 4 d14 2 n n LL AP 0 5 10 15 20 25 30 35 40 45 50 gpm 0 19 38 57 76 95 114 133 152 171 190 Ipm 7.5 15 fps 2.3 4.6 mps Flow Rate 0 kPa psi 11I (25mm) o y 110 16 A J 0 83 12 i m 69 10 W 7 55 8 H 41 6 28 4 I1 I1 14 2 0 5 10 15 20 25 30 35 40 45 50 55 60 gpm AP 0 19 38 57 76 95 114 133 152 171 190 209 228 Ipm 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps Flow Rate .AA A M E S FIRE & WATERWORKS A Watts Water Technologies Company ES-A-200013 1322 pp0 10 20 30 40 50 60 70 80 90 100 110 120 gpm 0 38 76 114 152 190 228 266 304 342 380 418 456 Ipm 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps Flow Rate kPa psi 2" (50mm) 83 12 69 10 55 8 41 6 28 4 14 2 0 0 0 25 50 75 100 125 150 175 200 gpm OP 0 95 190 285 380 475 570 665 760 Ipm 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps Flow Rate www.amesfirewater.com aOW Loi,I,C o R II 11. USA: Backflow- Tel: (916) 928-0123 • Fax: (916) 928-9333 Control Valves- Tel: (713) 943-0688 • Fax: (713) 944-9445 Canada: Tel: (905) 332-4090 • Fax: (905) 332-7068 0 2013 Ames Fire & Waterworks Page 1 of 5 ® FREEDOM° RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page. 1. DESCRIPTION Viking Freedom") Residential Concealed Pendent Sprinkler VK494 is a small thermosensitive, glass -bulb residential sprinkler designed for installation on concealed pipe systems where the appearance of a smooth ceiling is desired. The orifice design, with a K-Factor of 4.9 (70.6 metric*), allows the sprinkler's efficient use of available water supplies for the hydraulically designed fire -protection system. The fast response glass bulb operating element and special deflector characteristics meet the challenges of residential sprinkler standards. The sprinkler is pre -assembled with a threaded adapter for installation with a low -profile small -diameter cover assembly installed flush to the ceiling. The two- piece design allows installation and testing of the sprinkler prior to installation of the cover plate. The "push -on", "thread -off' design of the concealed cover plate assembly allows easy installation of the cover plate after the system has been tested and the ceiling finish has been applied, while also providing up to Y2" (13 mm) of vertical adjustment. The cover assembly can be removed and reinstalled, allowing temporary removal of ceiling panels without taking the sprinkler system out of service or removing the sprinkler. The Electroless Nickel PTFE (ENT) coating has been investigated for installation in corrosive atmospheres and is C-UL-US-EU Listed as corrosion resistant as indicated in the Approval Charts. The ENT finish is only available for the sprinkler assembly, the cover plate is not plated. 2. LISTINGS AND APPROVALS e@us UL Listed (C-UL-US-EU): Category VKKW eo Refer to the Approval Charts and Design Criteria on for C-UL-US-EU Listing requirements that must be followed. TECHNICAL DATA Specifications: Minimum Operating Pressure: Refer to the Approval Chart. Maximum Working Pressure: 175 psi (12 bar). Factory tested hydrostatically to 500 psi (34.5 bar). Thread size: 1/2" (15 mm) NPT Nominal K-Factor: 4.9 U.S. (70.6 metric*) Glass -bulb fluid temperature rated to -65 °F (-55 °C) * Metric K-factor measurement shown is in Bar. When pressure is measured in kPa, divide the metric 4 K-factor shown by 10.0. Material Standards: Sprinkler Body: Brass UNS-C84400 or QM Brass Deflector: Phosphor Bronze UNS-051000 Deflector Pins: Stainless Steel UNS-S30200 Button: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and SS UNS-S30400 Compression Screw: 18-8 Stainless Steel Yoke: UNS-S43000 Stainless Steel Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Cover Adapter: Cold Rolled Steel UNS-G10080, Finish: Clear Chromate over Zinc Plating Shipping Cap: Polyethylene Cover Plate Materials: Cover Plate Assembly: Copper UNS-C11000 and Brass UNS-C26800 Spring: Beryllium Nickel Solder: Eutectic Ordering Information: (Also refer to the current Viking price list.) Viking Freedom° Residential Concealed Pendent Sprinkler VK494 and Cover Plate Assembly must be ordered separately: Sprinkler: Order Sprinkler VK494 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A and ENT = JN Temperature Suffix: 155 °F (68 °C) = B, 175 °F (79 °C) = D, 200 °F (93 °C) = E For example, sprinkler VK494 with a Brass finish and a 200 °F (93 °C) temperature rating = Part No. 20759AE. Cover Plate Assembly: Base Part No. 13504 (2-3/4" diameter), Base Part No. 13642 (3-5/16" diameter), or Base Part No. 15394 (square cover plate, 3-5/16" diameter) Form No. F_012116 16.06.27 Rev 16.1 (New product, new page) Page 2 of 5 N4 I [a® FREEDOM° RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page. Specify finish and temperature rating of the cover plate assembly by adding the appropriate suffixes for the finish and the cover temperature rating to the base part number: Finish Suffix: Polished Chrome = F, Brushed Chrome = F-/B, Bright Brass = B, Antique Brass = B-/A, Brushed Brass = B-/B, Brushed Copper = E-/B, Painted White = M-/W, Painted Ivory = MA, Painted Black = M-/B Temperature Suffix: 135 °F/57 °C = A For example, cover 13504 with a Polished Chrome finish and a 135 °F/57 °C temperature rating = 13504FA. Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the "Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrenches": A. Heavy Duty Part No. 14047W/B** (available since 2006), or B. Head Cabinet Wrench Part No. 14031 *** (available since 2006) C. Optional Concealed Cover Plate Installer Tool Part No. 14412 (available since 2007) D. Optional Large Concealed Cover Plate Installer Tool Part No. 14867 (available since 2007) **Requires a ''/2' ratchet (not available from Viking). ***Also optional for removal of the protective cap. Ideal for sprinkler cabinets. Sprinkler Cabinet: Part No. 01731A (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches, releasing the deflector. Continued heating of the exposed sprinkler causes the heat -sensitive liquid in the glass bulb to expand, causing the glass to shatter, releasing the yoke and pip cap and sealing spring assembly.. Water flowing through the sprinkler orifice strikes the deflector, forming a uniform spray pattern over a specific area of coverage determined by the water supply pres- sure at the sprinkler to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY Viking Sprinkler Model VK494 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Sprinkler Maximum Temperature Rating Cover Large Square Temperature Nominal Ambient of the Cover Plate Cover Plate Cover Plate Bulb Color Classification Temperature Ceiling Assembly Base Part Base Part Base Part Rating' Temperature' (Required)' Number' Number' Number' Ordinary 155 °F (68 °C) 100 °F (38 °C) 135 °F (57 °C) 13504 13642 15394 Red Intermediate 175 °F (79 °C) 150 °F (65 °C) 135 °F (57 °C) 1 13504 1 13642 1 15394 1 Yellow Intermediate 200 °F (93 °C) 150 °F (65 °C) 135 °F (57 °C) 13504 13642 15394 Green Sprinkler Finishes: Brass and ENT Cover Plate Finishes: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black Corrosion Resistant Coatings5: ENT Footnotes The sprinkler temperature rating is stamped on the deflector. z Based on NFPA-13, NFPA 13R, and NFPA 13D. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. s Maximum ambient temperature for cover assembly is 100 °F (38 °C). 4 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 5 The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end -user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the ENT coating is applied to all exposed exterior surfaces, including the waterway. For ENT coated sprinklers, the Belleville spring is exposed. Form No. F_012116 16.06.27 Rev 16.1 Page 3 of 5 N4 I [a® FREEDOM° RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page. Approval Chart Viking VK494, 4.9 K-Factor Residential Concealed Pendent Sprinkler For systems designed to NFPA 13D or NFPA 13R. For systems designed to NFPA 13, refer to the design criteria. For Ceiling types refer to current editions of NFPA 13, 13R or 13D Sprinkler Base NPT Thread Size Nominal K-Factor Maximum Water Wor- Part Number' SIN king Pressure Inches mm U.S. metric 2 20759 VK494 1/2 15 4.9 70.6 175 psi (12 bar) Max. Coverage Flow Pressure Listings and Minimum Area 6 GPM (LPM) PSI(bar) Deflector to Installation Approvals3,s Spacing Ceiling Type Ft. 155 T (68 °C),175 T (79 °C), 200 T (93 °C) c UL us 4 Ft. X Ft. (m) (m X m) Temperature Rated Sprinklers EU 12 X 12 13 7.0 (3.7 X 3.7) (49.2) (0.48) 14 X 14 13 7.0 (4.3 X 4.3) (49.2) (0.48) Refer to Figure 2 Concealed with Cover Plate See Footnotes T10, & 11 8 16 X 16 13 7.0 (4.9 X 4.9) (49.2) (0.48) Assembly. See Footnote 9. (2.4) 18 X 18 17 12.0 (5.5 X 5.5) (64.4) (0.83) 20 X 20 20 16.7 (6.1 X 6.1) (75.7) (1.15) Footnotes Part number shown is the base part number. For complete part number, refer to current Viking price schedule. Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. Refer also to Design Criteria. ° Listed by Underwriter's Laboratories, Inc. for use in the U.S., Canada, and European Union. e Meets New York City requirements, effective July 1, 2008. 6 For areas of coverage smaller than shown, use the "Flow" and "Pressure" for the next larger area listed. Flows and pressures listed are per sprinkler. The distance from sprinklers to walls shall not exceed one-half the sprinkler spacing indicated for the minimum "Flow" and "Pressure' used. Cover Temperature Rating is 135 °F (57 °C). Cover Part No. 135041, 13642' (large diameter), or 15394' (square cover plate). e Other paint colors are available on request with the same listings as the standard finish colors. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. Custom colors are indicated on a label inside the cover assembly. Refer to Figure 3. 0 Accepted Cover Plate Finishes are: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black 9. " C-UL-US-EU Listed as corrosion resistant - Electroless Nickel PTFE (ENT) Form No. F_012116 16.06.27 Rev 16.1 Page 4 of 5 ® FREEDOM° RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page. DESIGN CRITERIA (Also refer to the Approval Chart on page 3.) UL Listina Reauirements (C-UL-US-EU): When using Viking Residential Concealed Pendent Sprinkler VK494 for systems designed to NFPA 13D or NFPA 13R, apply the listed areas of cover- age and minimum water supply requirements shown in the Approval Chart. For systems designed to NFPA 13: The number of design sprinklers is to be the four contiguous most hydraulically demanding sprinklers. The minimum required discharge from each of the four sprinklers is to be the greater of the following: • The flow rates given in the Approval Chart for NFPA 13D and NFPA 13R applications for each listed area of coverage, or • Calculated based on a minimum discharge of 0.1 gpm/sq. ft. over the "design area" in accordance with sections 8.5.2.1 or 8.6.2.1.2 of NFPA 13. • Minimum distance between residential sprinklers: 8 ft. (2.4 m). NOTE: Concealed sprinklers must be installed in neutral or negative pressure plenums only. IMPORTANT. Always refer to Bulletin Form No. F 080415 - Best Practices for Residential Sprinkler Handling and Installation. Also refer to Form No. F 080614 for general care, installation, and maintenance information. Viking sprinklers are to be in- stalled in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA and any other similar Authorities Having Jurisdiction, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Final approval and acceptance of all residential sprinkler installations must be obtained from the Authorities Having Jurisdiction. Sprinkler and Adapter Assembly • Protective cap removed • Use wrench 14047W/B** Sprinkler Wrench Part No. 14047W/B** Step 1: Carefully slide the wrench sideways around the deflector and pins NEVER install the sprinkler by applying the installation wrench across the frame arms. DO NOT overtighten. Use only the designated sprinkler wrenches, Viking Part Numbers 14047W/B** or 14031**. A leak tight seal should be achieved by turning the sprinkler clockwise 1 to 1-1/2 turns beyond finger tight. 2-1/4" (57 mm) diameter opening required in the ceiling. Step 2: 1 1 Carefully press the wrench upward and turn slightly to ensure engagement with the sprinkler wrench flats. Sprinkler wrench flat Figure 1: Sprinkler Installation and Proper Wrench Usage ** A 1/2" ratchet is required (Not available from Viking) Sprinkler frame arms Form No. F_012116 16.06.27 Rev 16.1 Page 5 of 5 N4 I [a® FREEDOM° RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page. 1/2" (15 mm) NPT 2-9/16" (65 Ok mm) Maximum 2-1/16" (52 mm) Minimum -000 NEW LAE N �- 2-3/4" (70 mm) or NOTE: Upon sprinkler activation, the deflector descends 3-5/16" (84 mm) to approximately 13116" (21 mm) below the sprinkler body. Figure 2: Sprinkler Dimensions and Cover Installation QQ�\�--p C US 7-0 a �2 O c� v� O VIKING0. All custom color painted cover plates will have an identifying label affixed to the inside of the cover that indicates the custom color and will have a representative sample (a paint dot) of the paint on the label. Figure 3: Identification of Custom Paint for Concealed Covers - -I . - \- . .... ., Figure 4: Square Cover Assembly 15394 Form No. F_012116 16.06.27 Rev 16.1 (New product, new page) Viking Plastics BiazeMast CPVC Pape Features • Sizes Available (Nominal): 3/4" (DN20) through 3" (DN80) pipe diameters, with a Standard Dimension Ratio (SDR) of 13.5 as specified in ASTM F442. • Environmental Specifications: Indoor use only. Maximum Ambient Temperature: 150°F (65°C) • Hazen -Williams C Value: 150 • Pressure Data: Working Pressure: 175 PSI (12.1 bar) at 150°F (65°C) • Specifications: Meets NFPA 13R and 13D standards for residential occupancies as well as NFPA 13 standards for light hazard occupancies. • Pipe meets or exceeds ASTM F442. • Certified by NSF International for potable water services. • CPVC pipe from Viking Plastics use compound cell class 23547 (demonstrated highest structural properties). • cULus Listed, FM Approved, New York City (MEA) Approved, LPCB Approved, CPVC PIPE PHYSICAL DATA e& u�a FM LPCB Nominal Pipe Size ..... Actual Outside Diameter Average Inside Diameter ''Weight per 15' (4,6 m) Length Length Approvals Part Number Inch DN Inch mm Inch mm Lb. Kg. Feet M 314" DN20 1.050 26,670 0.874 22,199 2.52 1,14 15 4.6 cU NSF usM 34PIPE 1" DN25 1.315 33,401 1.101 27,965 3.93 1,78 15 4.6 1PIPE 1 114" DN32 1.660 42,164 1,394 35,408 6.27 2,84 1 15 4.6 114PIPE 1 112" ❑N40 1.900 48,260 1.598 40,589 8.22 3,73 15 4.6 112PIPE 2" DN50 2.375 60,325 2.003 50,876 12.89 5,85 15 4.6 2PIPE 2112" DN65 2.875 73,000 2.423 61,500 18.86 8,55 15 4.6 212PIPE 3" DN80 3.500 88,900 2.950 74,900 28,01 12,71 15 4.6 3PIPE Nominal Pipe Size Actual Outside Diameter Average Inside Diameter *Weight per 10' (3,05 m) length Length Approvals Part Number Inch DN inch mm Inch mm Lb. Kg. Feet M 3/4" DN20 1.050 26,670 0.874 22,199 1.68 0,76 10 3,05 cU NSFFM 34PIPE10 1" DN25 1 1,315 33,401 1.101 27,965 2.62 1,19 10 3,05 1PIPE10 1 114" DN32 1.660 42,164 1.394 35,408 4.18 1.90 10 3,05 114PIPE10 1 1122' DN40 1.900 48,260 1,598 40,589 5.48 2,49 10 3,05 112PIPE10 2" DN50 2.375 60,325 2.003 50,876 8.59 3,90 10 3,05 2PIPE10 2112" DN65 2.875 73,000 2.423 61,500 12.57 5,70 10 3,05 1 212PIPE10 3" DN80 1 3.500 88,900 2,950 74,900 18.67 8,47 10 3,05 3PIPE10 NOTE: CPVC Pipe is produced in SDR 13.5 Dimensions in accordance with AS7M F442, Standard Dimension Ratio is She ratio of the outside pipe diameter to the wait thickness of the pipe. 9lazemastet® is a registered trademark of Lubrizol. Specifications subject to change without notice `Empty pipe weights IMPORTANT: Installers should receive thorough hands-on training in the proper methods of assembly and installation of CPVC products. Trusted above aJJTM �'� � Viking Plastics CPVC Pipe Product Specifications BlazeMastet-0 CPVC Pipe Corrosion resistant CPVC fire sprinkler pipe, when installed in strict accordance with the manufacturer's design and instal- lation instructions, is UL and c-UL Listed by Underwriters Laboratories for use in the following: • Meets NFPA 13R and 13D standards for residential occupancies as well as NFPA 13 standards for light hazard occupancies. • Residential occupancies up to and including four stories in height as defined by NFPA 13R. • Residential occupancies as defined in the Standard for Sprinkler Systems in One and Two Family Dwellings, NFPA 13D. Installation of private fire service mains and their appurtenances, NFPA 24. CPVC fire sprinkler pipe from Viking Plastics shall be employed in wet pipe systems only and are not listed for outdoor use. CPVC pipe must never be used in a system using compressed air or other gases. CPVC pipe from Viking Plastics also carries the following enhanced listings and approvals: • According to UL Listing • Can be flush at return air plenums • Exposed system risers NFPA 13D, 13R • Exposed basement NFPA 13D (solid wood joist) • Extended coverage (exposed) • 20' spacing on pendent in lieu of 15' • 18' spacing on sidewall in lieu of 14' • Use with combustible concealed sprinklers • UL Listed attic sprinkler head (to protect the Floor below) • UL Listed attic sprinkler head with wet system piping (feed main and ridge installation) New and enhanced listings and approvals are being pursued. Always check with the appropriate Listing and Approval agency for details on current listing parameters. CPVC pipe meets all applicable standards for pressure rated applica- tion as required in ANSI -NSF Standard 14 and complies with ANSI -NSF Standard 61 for health effects and are marked with the NSF-pw end use marking. All CPVC fire sprinkler pipe shall be Listed by Underwriters Laboratories for wet pipe systems, and shall carry a rated working pressure of 175 psi @ 150'F (12 bar @ 65.5"C). *The FM Approval is limited to use in wet pipe fire protection sprinkler systems for light hazard occupancies in both concealed and exposed applications with certain restrictions. Piping must always be installed in strict accordance to the manufacturer's DESIGN AND INSTALLATION GUIDE, including product storage and handling, joining methods, supporting and bracing, expansion and con- traction allowance and testing, etc. National Fire Protection Association (NFPA) Standards 13, 13D, and 13R must be referenced for design and installation requirements in conjunction with the installation instructions. Trusted above all`" • Exposed sidewall sprinkler listing for exposed pipe & fittings • 24' extended coverage sidewall sprinkler, 12" drop, 155T sprinkler head • 18' extended coverage sidewall sprinkler, 12" drop, 165T sprinkler head • 16' extended coverage sidewall sprinkler, 12" drop, 175T sprinkler head • 14' standard coverage sidewall sprinkler, 12" drop, 200T sprinkler head Factory Mutual Approved* • Factory Mutual Approval exposed • Factory Mutual Approval above drop -in ceilings • Factory Mutual Approval exposed w/Soffi-Steel soffiting covering system All CPVC fire sprinkler pipe from Viking Plastics is manufactured in the USA. All CPVC pipe shall be packaged immediately after its manufacture to prevent damage and shall be stored indoors after production, at the manufacturing site, until shipped from the factory. The pipe shall bear the logo of the listing agencies, and shall carry the National Sanitation Foun- dation (NSF) seal of approval for potable water applications. CPVC products are intended for use in areas where the maximum ambi- ent temperature does not exceed 150°F (65.5°C). If the ambient tempera- ture is expected to exceed this limitation, refer to the manufacturer's DE- SIGN AND INSTALLATION GUIDE for additional information on methods to reduce the pipe exposure temperatures. CPVC pipe is not intended to be installed in outdoor applications. CPVC pipe is intended to be used in wet pipe systems only and have not been investigated for use in dry pipe systems. Special installation and design criteria relative to pipe hanger spacings, piping and sprinkler restraint, sprinkler temperature rating, piping locations, testing procedures and friction loss characteristics are specified in the manufacturer's installation instructions provided with the pipe. The manufacturer's installation instructions should be reviewed and the Authority Having Jurisdiction consulted before installation. Pipe Clamps Fig. 22 - Hanger for CPVC Plastic Pipe & IPS Steel Pipe** Single Fastener Strap (B-Line 133181) Size Range: 3/4" (20mm) thru 2' (50mm) CPVC pipe Material: Pre -Galvanized Steel Function: Intended to perform as a hanger to support CPVC piping used in automatic fire sprinkler systems. The product acts as a hanger when tab is upward and the fastener screw is in the horizontal position. Fig. 22 can be installed on the top of a ream, but in this situation acts as a guide to the piping which is supported by the beam itself. It is not intended to support CPVC pipe from under a flat horizontal surface, such as a ceiling. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL) to support fire sprinkler piping. May be installed in wood using fasteners supplied with product, or into minimum 20 gauge rasimm) steel using (1) 114" x 1' tek type screw. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Features: Fig. 22 incorporates features which protect the pipe and ease installation. The flared edge design protects CPVC pipe from any rough surface. It is easily attached to the building structure using the special UL Listed hex head self threading screw* furnished with the product. It is recommended that rechargeable electric drills fitted with a hex socket attachment to be used as installation tools. No impact tools (such as a hammer) are allowed. Damage has been known to result from installations using impact type tools. No pre -drilling of a pilot hole in wood is required. Finish. Pre -Galvanized Order By: Figure number and pipe size. * Hardened hex head self threading screw is furnished with the product and is the minimum fastener size acceptable. ** With reduced spacing, consult factory. CPVC Max. Hanger Fastener Hex Approx. Pipe Size A B C Spacing Head Size W1.1100 Part No. in. (mml in. (min) in. in* in. (Mir) F1. (m) in. (am) Lbs. (kg) 22-314 3/4, (20} 27/76" (61.9) 15/16" (33.31 13/16" (30.2) 51/2 (1.671 3/16" (7.9) 9 (4.1} 22-1 1" (25) 211/4' (68.3) 17/16" (36.51 lV/16" (30.2) 6 (1,831 5/16" (7.9) 9 (4.11 22-11/4 11/4" (32) 31/16" (77.8) 15/8" (42.31 13/16" (30.2) 6112 A.1.981 5/16" (7.9) 11 (5,01 22-11/2 11/2" (40) 35/16" (84.1) 13/4' (44.41 13/1C (30.2) 7 (2.13) 5/76" (7.9) 12 (5,4) 22-2 2" (50) 33/d' (95.21 21/8' (K1) .. 13/16' (30.2) 8 (2,441 5/16" (7.9) 1.5 (5.81 All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Fire Protection Solutions 35 B-Line by J- 2 F m U m a n. Fig. 23 - Hanger for CPVC Plastic Pipe & IPS Steel Pipii Double Fastener Strap (13-Line B31132) Size Range: 9/4" (20mm) thru 3" (aommi CPVC pipe Material: Pre -Galvanized Steel Function: Intended to perform as a hanger to support CPVC piping used in automatic fire sprinkler systems. Fig. 23 can be installed on the top, bottom or side of a beam. Approvals: Underwriters Laboratories Listed in the USA (li and Canada (cli sizes 3/4' (20mm) thru 2" (50mrn) to support fire sprinkler piping. May be installed in wood using fasteners suppfied with product, or into minimum 20 gauge (0.9mm) steel using (2) 1/4" x V tek type screw. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Features: Fig. 23 incorporates features which protect the pipe and ease installation. The flared edge design protects the CPVC pipe from any rough surface. It also incorporates snap restrainers allowing easier and faster installation. Easily attaches to the building structure using the two UL Listed hex head self threading screws* furnished with the product. It is recommended that rechargeable electric drills fitted with a hex socket attachment be used as installation toots. No impact tools (such as a hammer) are allowed. Damage has been known to result from installations using impact type tools. No pre -drilling of a pilot hole in wood is required. Finish: Pre -Galvanized Order By: Figure number and pipe size * Hardened hex head self threading screw is furnished with the product and is the minimum fastener size acceptable. ** With reduced spacing, consult factory. Pipe Clamps (2) TO LCO' c&US LISTED CPVC Max. Hanger Fastener Hex Approx. Pipe Size A B C Spacing Head Size Wt./loo Part No. in. (mm) in. (min) in. lmml in. Imml R. (m► in. (mm) Lbs. NO 23-3/4 3/4' (20) 3118" (79.41 19/16° 139.7) 13/15" 130.2) 51/2 (1,67) 5/16" (7.9) 9 3.1) 23-1 1" (25) 33/8" (85.71 111/115 142.9) 13/15" 130.2) 6 (1,83) 5/16" 1 9 14.1) 23-11/4 11/4" (32) ON" (106.4) 23132' 153.1) 13)16" (30.2) 61/2 (1,96) 5/16" (7.91 11 (5.01 23-11/2 11/2" (40) 47/1s" (112.7) 27/32" (56.3) 13/15" (30.2) 7 (2.13) 5/16" 1 12 (5.4) 23-2 2" (50) 47/8" (123.8) 27/16" (61.9.) 13/16" (30.2) 8 12.44) 5116" 17,91 15 23-21/2 21/2" 165) 5318" (135.5) 211116° (68.3) 13/10" (30.2) Consult Factory 5/16" (7.91 22 (10.6) 23-3 3" (8o) V (152.4) 3" 17621 ...................... . 13/16" (30.2) Consult Factory 5/16" (7.91 25 01.3) All dimensions in charts and an drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Fire Protection soiutions 37 B-Lime fag T Pipe Clamps Fig. 24 - Hanger for CPVG Plastic Pipe & IPS Steel Pipli Double Fastener Strap Side Mounted (B-Line B3183) Size Range: 3/4" (20mm) thru 2" 150mm) CPVC pipe Material: Pre -Galvanized Steel Function: Intended to perform as a hanger to support CPVC piping used in automatic fire sprinkler systems. Can be installed on the top or on the bottom of a beam. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cii to support fire sprinkler piping. May be installed in wood using fasteners supplied with product, or into minimum 20 gauge (0.912mm) steel using (2} 1/4" x V tek type screws. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Features: Fig. 24 incorporates features which protect the pipe and ease installation. The flared edge design protects the CPVC pipe from any rough surface. Easily attaches to the building structure using the two UL Listed hex head self threading screws* furnished with the product. It is recommended that rechargeable electric drills fitted with a hex socket attachment be used as installation tools. No impact tools (such as a hammer) are allowed. Damage has been known to result from installations using impact type tools. No pre -drilling of a pilot hole in wood is required. Finish: Pre -Galvanized Order By: Figure number and pipe size * Hardened hex head self threading screw is furnished with the product and is the minimum fastener size acceptable. ** With reduced spacing, consult factory. CPVC Max. Hanger Fastener Hex Approx. Pipe Size A B C Spacing Head Size Wt./100 Part No. in. (mm) in. {mmi in. Imml in. (mml K W in. Imm) Lbs. ft) 24-3/4 3/4 (20) 25/ir 68.1) 15/32" 27.6i 13/16" (30,2) 51/2 11.67) 5/16" (7.9) 9 (4.1) 24-1 1" (25) 251C 165.7) 15/16" (33.3) 13/111" (30.2) 6 (1.83) 5/I6" (7.9) 9 0.1) 24-11/4 11/4" (32) 3" (76.2} 11/2" (38.1) 13/16" (30.2i 61/2 (1,96} 5/15" (7.9) 11 15.0j 24-11/2 11/7" (40) 31/4" (82.5) 15/8" (42.3) 13/16' (39.2i 7 12.13) 5/15" (7.9) 12 (5.4) 24-2 2" (50) 3.11/16" (93.7) 127/3P' (43.6) 13/16' 130.2} 8 12.44) 5/16" (7.9) 15 (5.8) Fig. 25 - Surge Restrainer Size Range: — One size fits 3/4' (20mm) thru 2" (40mrn) pipe. Material: — Pre -Galvanized Steel Function: — Designed to be used in conjunction with Fig. 200 band hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficiently Installed by snapping into a locking position on the band hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association NFPA 13, 2010 edition, 9.2.3.4.4.1 and 9.2.3.4.4.4 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals: — Underwriters Laboratories Listed only when used with band hanger Fig. 700, in the USA (UL) and Canada (cUL). Finish: Pre -Galvanized Order By: Figure number and band hanger, size from 3/4 (20mm) thru 2' (40mm}. Patent #5,344,108 B-Line by Ail dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. 38 Fire Protection Solutions Pipe Clamps Fig. 28 - "Stand -Off- Hanger & Restrainer for CPVC Plastic Pipe & 1PS Steel Pipe ** Size Range: — 3/4" (20mm) through 2" (50mm) Material: — Steel, Pre -Galvanized Function: — Designed to be used as a hanger and restrainer for CPVC piping where the "stand-off' design will ease installation by eliminating the need for wood blocking. Features: • Flared edge design protects CPVC pipe from any rough or abrasive surfaces. • Unique twist and lock design holds pipe firmly in place and allows retrofit type of installation. • The 'Stand -Off" design eliminates the need for wood block extension. • Can be installed on horizontal or vertical piping regardless of mounting surface orientation. • Attaches easily to wood structure with two hex head self -threading screws furnished with product. • Installs easily using rechargeable electrical driver with 5/16' P.9mnn) extension socket eliminating impact tool damage to pipe. • Attaches easily to steel, minimum 18 gauge (1.024mm) with (2) 1/4" x 1" tek type self drilling tapping screws. • UL Listed as a hanger and a restrainer for fire sprinkler piping. Approvals: — Underwriters Laboratory Listed in the USA (ULI and Canada (cUL) to support automatic fire sprinkler systems. May be installed into wood using fasteners supplied with product, or into minimum 18 gauge steel using (2) 1/4" x 1' tek type screws. Meets and exceeds the requirements of NFPA 13, 13R and 131). Fig. 28 satisfies the UL vertical restraint requirement where needed. UL Listed as a hanger and vertical restraint when installed on 3/8" (9.5mm) composite wood material. Use two Fig. 27B Speed Nuts when used as a hanger and restraint. Use one Fig. 278 -Speed Nut on the upper installed screw when used as a hanger only. Order by: — Figure number and pipe size. Pat:. # 7,455,268, Pat. # 7,832,248 ** With reduced spacing, consult factory. Fig.27B (1] Required High Side of Hanger Application Hanger Application Fig. 27B (2) Required ' Hanger and Restraint Application Pipe Size A B C Max Hanger Approx. Spacing wt./100 Part No. in. (nun) in. (mm) in. imm) in. (mm) F1. (ml lbs. (kg) 283/4 314 (201 31/32" (77.01 2" (50.8) 31/2', (88.9) 51/2 (1.671 18 18.11 28-1 1" (25) V%" (84.1) 23/iC (55.61 31/2" 188.9) 6 (1.831 21 (9.5) 28-11/4 11/4" (32) 351a" (92.11 23/8" ou) 31/z" (88.9) 61/2 (1.981 23 (10.41 28-11/2 11/2' (40) 4" (101.6) 21/2" (63.51 3112" (88A) 7 (2.131 31 (14.61 28-2 2" (501 41/2" 11143) 211/16" (68.3) 35/a" (92.1) 8 (2.44) 34 (15,4) All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. 40 Fire Protection Solutions Pipe Clamps Fig. 28M - Offset Hanger & Restrainer for CPVC Plastic Pipe and IPS Steel Pipe (J)TOLC®" Size Range: 3/4' (20mm} thru 2' (32mm) C &us Material: Steel, Pre -Galvanized LISTED Function: Designed to be used as a hanger and restrainer for CPVC piping or steel piping where the "stand-off" design will ease installation by eliminating the need for wood blocking. Features: • Flared edge design protects CPVC pipe from any rough or abrasive surfaces • Unique snap -on design holds pipe firmly in place and allows retrofit type of installation • The "Stand -Off" design eliminates the need for wood block extension • Can be installed on horizontal or vertical piping regardless of mounting surface orientation • Attaches easily to wood structure with two hex head self -threading screws furnished with product • Installs easily using rechargeable electrical driver with 5116" (7.smm} extension socket eliminating impact tool damage to pipe • Attaches easily to steel, minimum 18 gauge (1.024mm) with (2) 114" x 1 " tek type self drilling tapping screws • cULus Listed as a hanger and a restrainer for fire sprinkler piping Installation Note: When installed In wood structural members and threads from the #10 x 1" screws are exposed, use Fig. 27B speed nut to secure Approvals: Underwriters Laboratory Listed in the USA (UL) and Canada (cUL) to support automatic fire sprinkler systems. May be installed into wood using fasteners screws. Meets and exceeds the requirements of NFPA 13, 13R and 13©. Fig. 28M satisfies the UL vertical ' restraint requirements where needed. Order By: Figure number and pipe size Patent #7,744,042 ** With reduced spacing, consult factory Fig. 27B (2) Required Hanger and Restraint Application Fig. 27B (ll Required High Side of Hanger ii n Detail A Hanger Application Pipe Size A Hale Dia. B C Max Spacing* Approx. WtJ10o Part No. in. (mml in. (mm) in. (mml in. Win) in. (mm1 16s. (kg) 28M-3/4 3/4" (201 2' (50.81 3/16" 14.8) 35hs" 184.1) 5'-6"' (1676) 9 (4.11 28M-1 V (251 21/8" (54.01 3/16` 14.8) 31/2" Ia8.9) 6'-0" (1829) 12 15.41 28M-11/4 1114" (821 25116 (58.71 3/i ' (4.8) 31/2" 188.9) S' 6" (1981) 13 (5.91< 28M-11/z 11/2" (49) 27116 (51.91 3/16` 14.81 31/8" 196.4) T-0" (21331 14 (6.3) 28M-2 2" (501 2518" (66.71 3/1e' (4,81 47/16" (112.7) 8'-0" (2438( 1s 16.3) * Required per NFPA 13 for CPVC plastic pipe All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified Fire Protection Solutions 41 13-Une UY T•l