BLD2022-0918_Manufacturer_Specifications_and_Installation_Instructions_7.13.2022_8.26.18_AM_2985983Product Data
Performance
P'r°n SERIES
Carrier air conditioners with Puron ® refrigerant provide a
collection of features unmatched by any other family of
equipment. The 24AHA4 has been designed utilizing Carrier's
Puron refrigerant. This environmentally sound refrigerant allows
you to make a responsible decision in the protection of the earth's
ozone layer.
NOTE: Ratings contained in this document are subject to
change at any time. Always refer to the AFM directory
(www.shridirectoryorg) for the most up-to-date ratings
information.
INDUSTRY LEADING
FEATURES / BENEFITS
Energy Efficiency
• 14 SEER/11.7 -12.2 EER
(Based on tested combinations)
Sound
• Levels as low as 66 dBA
Design Features
• Small footprint
• WeatherArmor- cabinet
— AlI steel cabinet construction
— Mesh coil guard
Reliability, Quality and Toughness
• Scroll compressor
• Factory -supplied filter drier
• High pressure switch
• Line lengths up to 250' (76.2 m)
• Low ambient operation
(down to-20°F/-28.9'C with low ambient
accessories)
cc
DIMENSIONS - ENGLISH
ELECTRICAL
G
H
J
K
L
M
N
P
OPERATNG
SHRIN0
NG
UI1fT
SERIES
CHARACTERISTICS
A
B
C
D
E
F
WEIGHTIbsl
WEKKiTlbsl
DMENSIONS IL x W x HI
211HA116
6
%
0
0
0
31 1!8"
36 15/16'
14 9116'
7fi'
23 7l16'
1T 3116"
23 118'
28 1115"
13'
6 5!6"
77 t14"
518'
2 T18'
S 13116'
146
166
42 15116' X 18' X 34 118'
24AHA424
0
X
0
0
0
31 118"
36 15/16'
14 9116'
IV
23 7116"
17 3116'
23 118"
28 1116'
14"
6 3!-0"
11 5J6'
314'
2 T18'
S 13J16'
748
168
42 15l16' % 18' X 3/ 118'
24AHA430
0
x
0
0
0
37 118"
44 IJ2'
17 1116'
18 7116'
30 112'
10 5/8'
29 I/V
34 1116'
13 11116"
8 118'
15 7/6'
3J4"
3 318"
6 318'
183
213
50 t!2'" X 20 t/2'" X 40 1!B'"
24AHA436
0
X
0
%
X
37 118-
44 1J2'
11 1116'
18 7116'
30 112"
19 518"
29 11B'
34 IJi6'
13 11116"
6 1!8"
1 15 718'
7J8'
3 318"
6 308'
184
214
50 112" X 20 1/2" X 40 118"
24AHA448
0
N
1 0
1 X
I X
1 31 118-
44 112'
17 106'
18 7116'
30 112"
19 518'
29 118'
34 1116'
14 112'
8 112"
1 18 718"
7J8'
3 318'
6 318'
213
243
50 112" X 20 112" X 40 118"
24AHA460
0
X
I D
I %
I X
143 7J8'
4A 112'
I7 1116'
18 1116"
30 112'
19 518'
35 11B'
40 1116,
11 112'
8 112"
1 18 7"'
118'
3 310'
J 6 3/8'
245
275
50 112' X 20 112" X 46 118"
% = YES
NSy
x
�
fV
d
N
4X
O=MO
MINMUM
UNIT SIZE MOUNTING PAD
DIMENSIONS
t8,2a 23X 42"
30,36,46,60 24"" 1 50'
in
1. CLEARANCE REQUIREMENTS; SINGLE UNIT APPLICATIONS: WITH COIL FACING WALL ALLOW 6 IN. MINIMUM CLEARANCE
ON COIL SIDE AND COIL END AND 20 IN. MINIMUM CLEARANCE ON FAN SIDE. WITH FAN FACING WALL: ALLOW 8 IN.
MINIMUM CLEARANCE ON FAX SIDE ANQ 6 IN. ON COIL END AND 20 IN. MINIMUM CLEARANCE ON COIL SIDE.
MULTI -UNIT APPLICATIONS: ALLOW 24 IN. MINIMUM CLEARANCE BETWEEN FAN AND COIL SIDES OF MULTIPLE UNITS.
111,11E UNITS SO DISCHARGE OF ONE DOES NOT ENTER INLET OF ANOIHER.WHEH TWO UNITS ARE INSTALLED END TO END
WITH THE COIL ENOS FACING EACH OTHER ALLOW 12 IN. MINIMUM CLEARANCE BETWEEN UNITS.
COMPRESSOR END SERVICE CLEARANCE: ALLOW 24 ]N. MINIMUM CLEARANCE ON COMPRESSOR END WHEN UNITS ARE STACKED OR
THERE IS LESS THAN 40 IN. OF CLEARANCE ABOVE THE TOP OF THE UNIT. IF THERE IS 40 IN. CLEARANCE ABOVE UNIT AND
THE TOP PANEL IS ACCESSIBLE FOR REMOVAL ALLOW 8 IN MINIMUM CLEARANCE ON COMPRESSOR END FOR SERVICE.
IMPORTANT: WHEN INSTALLING SINGLE OR MULTIPLE UNITS IN AN ALCOVE, ROOF WELL, OR PARTIALLY ENCLOSED AREA,
ENSURE THERE IS ADfOUATE VENTILATION TO PREVENT RECIRCULATION OF DISCHARGE AIR.
2. MINIMUM OUTDOOR OPERATING AMBIENT IN COOLING
112' MODE IS 55'F, MAX. 125'F.
3. SERIES DESIGNATION IS THE 13TH POSITION OF THE
UNIT MODEL NUMBER.
4. CENTER OF GRAVITY
4 3/16' S. ALL DIMENSIONS ARE IN 'INCHES' UNLESS NOTED.
FIELD CONTROL SUPPLY
WIRE ENTRY
718' HOLE WIGROMMEI
VAPOR LINE CONN.
IALE SWEAT CONN.
L
LIQUID LINE i
SWEAT CONN
JUNCTION BOX FOR
POWER SUPLLY AND
CONTROL CONNECTIONS
1 7l16"
1 7l16,
8 1.116"
4 112"
FIELD POWER SUPPLY CONN.
HOLE SIZES PROVIDED:
0 118" ROLE WITH
0 1 118' KNOCKOUT AND
0 1 316' KNOCKOUT
MODEL NUMBER NOMENCLATURE
1 i 2 3 4 5 6 7 8 9 10 11 12 13
N N A A A/N N- N N A/N A/N A/N N N
2 4 A H A 4 1 8 A 0 0 3 0
Product Product Product Major Minor
SEER Variations Open Open Voltage
Series Family Type Series Series
- -- _ - Cooling _ _ .. _ .. _ . _ - - - -- --- _..:
0= 0= 3=2081230-1
24=AC A = AC Horizontal I Capacity A= Not Not 5=208/230-3 0, 1, 2...
4=14
SEER Standard
Discharge Defined Defined 6=460/3
® C UL US
Ptiron.
Use of the AHRi Certified
TM Mark indicates a
manufacturer's
participation in the
program For verification
of Certification for individual
products, go to
www.ahridirectory org.
PHYSICAL DATA
UNIT SIZE - SERIES 18-30 24-30 30-30 36-30,50,60 48-30,50,60 60-30,50,60
COMPRESSOR TYPE Scroll
REFRIGERANT Puron® (R-410A)
6.40 (2.90) 6.50 (2.95) 8.60 (3.90) 8.90 (4.04) 9.00 (4.08) 10.60 (4.81)
Charge lb (kg} - - -
COND FAN Propeller Type, Direct Drive
Air Discharge Horizontal
Air Oty (CFM) 1285 1285 1900 2615 2615 2785
Motor HP 1/12 -1/12 1/10 1/4 1/4 1/4
Motor RPM 800 800 800 800 800 800
COND COIL
Face Area (Sq ft) 7.3 - 7.3 12.1 12.1 12.1 14.1
Fins per In. 20 20 20 20 20 20
Rows 2 2 2 2 2 2
Circuits 3 3 3 3 3 4-
VALVE CONNECT. (In. ID)
Vapo► 5/8 3/4 3/4 7/8 7/8 7/8
Liquid 3/8
REFRIGERANT TUBES* (In. OD)
Rated Vapor* 5/8 3/4 3/4 7/8 7/8 1 1/8
Max Liquid Linet 3/8
* Units are rated with 25 fl (7.6 m) of lineset length. See Vapor Line Sizing and Cooling Capacity Loss table when using other sizes and lengths of lineset.
Note: See unit Installation Instruction for proper installation.
t See Liquid Line Sizing For Cooling Only .Systems with Puron Refrigerant tables.
2
K c yr . � }•a�k� t. -' �' �Xr sr'y' Wj rq&` i �S"�� �x#' 4a ree
} 1 '$iv't J; s .� F
Crrie`tt' 'a`ir .� r`. n'ct - mi,`.'*" A"�,si'�"`�:� "' g r/
WK
MOM= =-..m
Turn to the experts
Product Data
PERFORMANCE
• Communicating variable -speed, constant airflow (VCA) ECM blower
motor for electrically efficient operation all year long in heating,
cooling and continuous fan operation
• Two -speed inducer motor, and two -stage gas valve.
• Power HeatTM Silicon Nitride Hot Surface Igniter.
• Ideal Humidity SystemTM technology can dehumidify a home without
a call for cooling.
• Integral part of the Ideal Humidity® System Technology.
• ComfortFanTM technology allows control of continuous fan speed
from a compatible thermostat.
• SmartEvapTM technology helps control humidity levels in the home
when used with a compatible humidity control system.
• Aluminized -steel primary heat exchanger.
• Stainless -steel condensing secondary heat exchanger.
• External Media Filter Cabinet included.
at 1263 . Fully -insulated casing including blower section.
The 59TN613 Multipoise Variable Speed Condensing Gas Furnace
features the two -stage Infinity® System. The Comfot Heat® Technology
two -stage gas system is at the heart of the comfort, provided by this
furnace, along with the Infinity variable --speed constant airflow ECM
blower motor, and two -speed inducer motor. With an Annual Fuel
Utilization Efficiency (AFUE) of up to 96.7%, the Infinity two -stage gas
furnace provides exceptional savings when compared to a standard
furnace. This Infinity Gas Furnace also features 4-way multipoise
installation flexibility, and is available in five model sizes. The 59TN6B
can be vented for direct vent/two-pipe, ventilated combustion air, or
single -pipe applications. A Carrier Infinity Control and Infinity Air
Conditioner or Heat Pump can be used to form a complete Infinity
System. All sizes can be installed in air quality management districts
with a 40 ng/3 NOx emissions requirement. All sizes are design certified
in Canada.
INFINITY' i
�ESIBy
CEQ� cFA
Use of the AHRI Certified TM
Mark indicates a manufacturer's
participation in the program. For
ISO 9001 verification of certification for in-
dividual products, go to
Quality www,ahridirectory.org .
A200620
INSTALLATION FLEXIBILITY
4-way multipoise design for upflow, downflow or horizontal
installation, with unique vent elbow and optional through- the -cabinet
downflow venting capability.
Ideal height 35-in. (889 mm) cabinet: short enough for taller coils, but
still allows enough room for service.
Direct-vent/sealed combustion, single -pipe venting or ventilated
combustion air.
APPLICATIONS
• Self -diagnostics and extended diagnostic data through the Advanced
Product Monitor (APM) accessory or Infinity User Interface.
• Propane convertible with gas conversion accessory
• Convenient Air Purifier and Humidifier connections.
• Compatible with single- and multiple -zone Infinity systems.
CERTIFICATIONS
All sizes meet ENERGY STAR® Version 4.1 criteria for gas furnaces:
95%+ AFUE.
Cabinet air leakage less than 2.0% at 1.0 in. W.C. and cabinet air
leakage less than 1.4% at 0.5 in. W.C. when tested in accordance with
ASHRAE standard 193.
59TN613: Product Data
SPECIFICATIONS
The furnace should be sized to provide 100 percent of the design heating load requirement plus any margin that occurs because of furnace model size
capacity increments. None of the furnace model sizes can be used if the heating load is 20,000 BTU or lower. Use Air Conditioning Contractors of
America (Manual J and S); American Society of Heating, Refrigerating, and Air -Conditioning Engineers; or other approved engineering method to
calculate heating load estimates and select the furnace. Excessive oversizing of the furnace may cause the furnace and/or vent to fail prematurely,
customer discomfort and/or vent freezing.
Failure to follow these guidelines is considered faulty installation and/or misapplicat
I pf the furnace; and resulting failure, damage, or repairs may
impact warranty coverage.
FURNACE SIZE 06OC17-14 08OC17-14 08OC21-20 10OC21-22 120C24- 22
HEATING CAPACITY AND
EFFICIENCY
High Heat
(BTUH)
60,000
80,000
80,000
100,000
120,000
Input
Low Heat
(BTUH)
39.000
52,000
52,000
65,000
78,000
High Heat
(BTUH)
58,000
78,000
78,000
98,000
117,000
Output
Low Heat
(BTUH)
38,000
50,000
51,000
63,000
76,000
Certified Temperature
High Heat
35 - 65
(19 - 36)
40 - 70
(22 - 39)
40 - 70
(22 - 39)
45 - 75
(25 - 42)
45 - 75
(25 - 42)
Rise Range OF (°C)
Low Heat
30 - 60
(17 - 33)
30 - 60
(17 - 33)
30 - 60
(17 - 33)
30 - 60
(17 - 33)
30 - 60
(17 - 33)
AIRFLOW CAPACITY AND SLOWER
DATA
Rated External Static
Pressure (in. w.c.)
Heating
0.12
0.15
0.15
0.20
0.20
Cooling
0.50
0.50
0.50
0.50
0.50
Airflow Delivery
@ Rated ESP (CFM)
High Heat
1055
1240
1345
1575
1820
Low Heat
755
1008
1095
1365
1555
Coding
1280
1310
1945
2160
2135
Cooling Capacity (tons)
400 CFMlton
3
3.50
4.50
5
5.50
350 CFM/ton
3.50
4
5.50
6
6
Direct -Drive Motor Type
Electronically Commutated Motor (ECM)
Direct -Drive Motor HP
1/2
1/2
1
1
1
Motor Full Load Amps
8.50
8.50
12.80
12.80
12.80
RPM Range
300 -1300
Speed Selections
Variable (Communicating)
Blower Wheel Dia x Width in.
11 x 8 11 x 8 I 11 x10 1 11 x 10 11 x 11
Air Filtration System
Factory Supplied Extemal Media Cabinet
Field Supplied Filter
Filter Used for Certified Watt Data*
325531-20
ELECTRICAL DATA
Input Voltage
Vohs -Hertz -Phase
115-60-1
Operating Voltage Range
Min -Max
104-127
Maximum Input Amps
Amps
9.30
9.30
13.60
13.70
13.70
Unit Ampacity
Amps
12.60
12,60
17.90
18.00
18.00
Minimum Wire Size
AWG
14
14
12
12
12
Maximum Wire Length
@ Minimum Wire Size
Feet
29
29
32
31
31
(M)
(9.0)
(9.0)
(9.8)
(9.7)
(9.7)
Maximum Fuse/Ckt Bkr
(Time -Delay Type Recommended)
Amps
15
15
20
20
20
Transformer Capacity (24vac output)
40 VA
Extemal Control Power Available
Heating
24.3 VA
Coding
34.6 VA
CONTROLS
Gas Connection Size
1/2" - NPT
Burners (Monoport)
3 4 1 4 5 1 6
Gas Valve (Redundant) Manufacturer
White Rogers
Minimum Inlet Gas pressure (in. we)
4.50
Maximum Inlet Gas pressure (in. wc)
13.60
Manufactured (Mobile) Home Kit
Not approved for Modular {Mobile Home) use
Ignition Device
Sificon Nitride
Heating Blower Control (Heating Off -Delay)
Adjustable: 90, 120, 150, 180 seconds
Cooling Blower Control (Time Delay Relay)
90 seconds
Communication System
Infinity; Infinity Zoning
Thermostat Connections
R, W/W1, W2 Y/Y2, Y1, G, Com 24V, DHUM
Accessory Connections
EAC (115vac); HUM (24vac); 1-stg AC (via Y/Y2)
•. See Accessory List for part numbers available
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.