BLD2022-0918_Manufacturer_Specifications_and_Installation_Instructions_7.13.2022_8.26.18_AM_2985983Product Data Performance P'r°n SERIES Carrier air conditioners with Puron ® refrigerant provide a collection of features unmatched by any other family of equipment. The 24AHA4 has been designed utilizing Carrier's Puron refrigerant. This environmentally sound refrigerant allows you to make a responsible decision in the protection of the earth's ozone layer. NOTE: Ratings contained in this document are subject to change at any time. Always refer to the AFM directory (www.shridirectoryorg) for the most up-to-date ratings information. INDUSTRY LEADING FEATURES / BENEFITS Energy Efficiency • 14 SEER/11.7 -12.2 EER (Based on tested combinations) Sound • Levels as low as 66 dBA Design Features • Small footprint • WeatherArmor- cabinet — AlI steel cabinet construction — Mesh coil guard Reliability, Quality and Toughness • Scroll compressor • Factory -supplied filter drier • High pressure switch • Line lengths up to 250' (76.2 m) • Low ambient operation (down to-20°F/-28.9'C with low ambient accessories) cc DIMENSIONS - ENGLISH ELECTRICAL G H J K L M N P OPERATNG SHRIN0 NG UI1fT SERIES CHARACTERISTICS A B C D E F WEIGHTIbsl WEKKiTlbsl DMENSIONS IL x W x HI 211HA116 6 % 0 0 0 31 1!8" 36 15/16' 14 9116' 7fi' 23 7l16' 1T 3116" 23 118' 28 1115" 13' 6 5!6" 77 t14" 518' 2 T18' S 13116' 146 166 42 15116' X 18' X 34 118' 24AHA424 0 X 0 0 0 31 118" 36 15/16' 14 9116' IV 23 7116" 17 3116' 23 118" 28 1116' 14" 6 3!-0" 11 5J6' 314' 2 T18' S 13J16' 748 168 42 15l16' % 18' X 3/ 118' 24AHA430 0 x 0 0 0 37 118" 44 IJ2' 17 1116' 18 7116' 30 112' 10 5/8' 29 I/V 34 1116' 13 11116" 8 118' 15 7/6' 3J4" 3 318" 6 318' 183 213 50 t!2'" X 20 t/2'" X 40 1!B'" 24AHA436 0 X 0 % X 37 118- 44 1J2' 11 1116' 18 7116' 30 112" 19 518" 29 11B' 34 IJi6' 13 11116" 6 1!8" 1 15 718' 7J8' 3 318" 6 308' 184 214 50 112" X 20 1/2" X 40 118" 24AHA448 0 N 1 0 1 X I X 1 31 118- 44 112' 17 106' 18 7116' 30 112" 19 518' 29 118' 34 1116' 14 112' 8 112" 1 18 718" 7J8' 3 318' 6 318' 213 243 50 112" X 20 112" X 40 118" 24AHA460 0 X I D I % I X 143 7J8' 4A 112' I7 1116' 18 1116" 30 112' 19 518' 35 11B' 40 1116, 11 112' 8 112" 1 18 7"' 118' 3 310' J 6 3/8' 245 275 50 112' X 20 112" X 46 118" % = YES NSy x � fV d N 4X O=MO MINMUM UNIT SIZE MOUNTING PAD DIMENSIONS t8,2a 23X 42" 30,36,46,60 24"" 1 50' in 1. CLEARANCE REQUIREMENTS; SINGLE UNIT APPLICATIONS: WITH COIL FACING WALL ALLOW 6 IN. MINIMUM CLEARANCE ON COIL SIDE AND COIL END AND 20 IN. MINIMUM CLEARANCE ON FAN SIDE. WITH FAN FACING WALL: ALLOW 8 IN. MINIMUM CLEARANCE ON FAX SIDE ANQ 6 IN. ON COIL END AND 20 IN. MINIMUM CLEARANCE ON COIL SIDE. MULTI -UNIT APPLICATIONS: ALLOW 24 IN. MINIMUM CLEARANCE BETWEEN FAN AND COIL SIDES OF MULTIPLE UNITS. 111,11E UNITS SO DISCHARGE OF ONE DOES NOT ENTER INLET OF ANOIHER.WHEH TWO UNITS ARE INSTALLED END TO END WITH THE COIL ENOS FACING EACH OTHER ALLOW 12 IN. MINIMUM CLEARANCE BETWEEN UNITS. COMPRESSOR END SERVICE CLEARANCE: ALLOW 24 ]N. MINIMUM CLEARANCE ON COMPRESSOR END WHEN UNITS ARE STACKED OR THERE IS LESS THAN 40 IN. OF CLEARANCE ABOVE THE TOP OF THE UNIT. IF THERE IS 40 IN. CLEARANCE ABOVE UNIT AND THE TOP PANEL IS ACCESSIBLE FOR REMOVAL ALLOW 8 IN MINIMUM CLEARANCE ON COMPRESSOR END FOR SERVICE. IMPORTANT: WHEN INSTALLING SINGLE OR MULTIPLE UNITS IN AN ALCOVE, ROOF WELL, OR PARTIALLY ENCLOSED AREA, ENSURE THERE IS ADfOUATE VENTILATION TO PREVENT RECIRCULATION OF DISCHARGE AIR. 2. MINIMUM OUTDOOR OPERATING AMBIENT IN COOLING 112' MODE IS 55'F, MAX. 125'F. 3. SERIES DESIGNATION IS THE 13TH POSITION OF THE UNIT MODEL NUMBER. 4. CENTER OF GRAVITY 4 3/16' S. ALL DIMENSIONS ARE IN 'INCHES' UNLESS NOTED. FIELD CONTROL SUPPLY WIRE ENTRY 718' HOLE WIGROMMEI VAPOR LINE CONN. IALE SWEAT CONN. L LIQUID LINE i SWEAT CONN JUNCTION BOX FOR POWER SUPLLY AND CONTROL CONNECTIONS 1 7l16" 1 7l16, 8 1.116" 4 112" FIELD POWER SUPPLY CONN. HOLE SIZES PROVIDED: 0 118" ROLE WITH 0 1 118' KNOCKOUT AND 0 1 316' KNOCKOUT MODEL NUMBER NOMENCLATURE 1 i 2 3 4 5 6 7 8 9 10 11 12 13 N N A A A/N N- N N A/N A/N A/N N N 2 4 A H A 4 1 8 A 0 0 3 0 Product Product Product Major Minor SEER Variations Open Open Voltage Series Family Type Series Series - -- _ - Cooling _ _ .. _ .. _ . _ - - - -- --- _..: 0= 0= 3=2081230-1 24=AC A = AC Horizontal I Capacity A= Not Not 5=208/230-3 0, 1, 2... 4=14 SEER Standard Discharge Defined Defined 6=460/3 ® C UL US Ptiron. Use of the AHRi Certified TM Mark indicates a manufacturer's participation in the program For verification of Certification for individual products, go to www.ahridirectory org. PHYSICAL DATA UNIT SIZE - SERIES 18-30 24-30 30-30 36-30,50,60 48-30,50,60 60-30,50,60 COMPRESSOR TYPE Scroll REFRIGERANT Puron® (R-410A) 6.40 (2.90) 6.50 (2.95) 8.60 (3.90) 8.90 (4.04) 9.00 (4.08) 10.60 (4.81) Charge lb (kg} - - - COND FAN Propeller Type, Direct Drive Air Discharge Horizontal Air Oty (CFM) 1285 1285 1900 2615 2615 2785 Motor HP 1/12 -1/12 1/10 1/4 1/4 1/4 Motor RPM 800 800 800 800 800 800 COND COIL Face Area (Sq ft) 7.3 - 7.3 12.1 12.1 12.1 14.1 Fins per In. 20 20 20 20 20 20 Rows 2 2 2 2 2 2 Circuits 3 3 3 3 3 4- VALVE CONNECT. (In. ID) Vapo► 5/8 3/4 3/4 7/8 7/8 7/8 Liquid 3/8 REFRIGERANT TUBES* (In. OD) Rated Vapor* 5/8 3/4 3/4 7/8 7/8 1 1/8 Max Liquid Linet 3/8 * Units are rated with 25 fl (7.6 m) of lineset length. See Vapor Line Sizing and Cooling Capacity Loss table when using other sizes and lengths of lineset. Note: See unit Installation Instruction for proper installation. t See Liquid Line Sizing For Cooling Only .Systems with Puron Refrigerant tables. 2 K c yr . � }•a�k� t. -' �' �Xr sr'y' Wj rq&` i �S"�� �x#' 4a ree } 1 '$iv't J; s .� F Crrie`tt' 'a`ir .� r`. n'ct - mi,`.'*" A"�,si'�"`�:� "' g r/ WK MOM= =-..m Turn to the experts Product Data PERFORMANCE • Communicating variable -speed, constant airflow (VCA) ECM blower motor for electrically efficient operation all year long in heating, cooling and continuous fan operation • Two -speed inducer motor, and two -stage gas valve. • Power HeatTM Silicon Nitride Hot Surface Igniter. • Ideal Humidity SystemTM technology can dehumidify a home without a call for cooling. • Integral part of the Ideal Humidity® System Technology. • ComfortFanTM technology allows control of continuous fan speed from a compatible thermostat. • SmartEvapTM technology helps control humidity levels in the home when used with a compatible humidity control system. • Aluminized -steel primary heat exchanger. • Stainless -steel condensing secondary heat exchanger. • External Media Filter Cabinet included. at 1263 . Fully -insulated casing including blower section. The 59TN613 Multipoise Variable Speed Condensing Gas Furnace features the two -stage Infinity® System. The Comfot Heat® Technology two -stage gas system is at the heart of the comfort, provided by this furnace, along with the Infinity variable --speed constant airflow ECM blower motor, and two -speed inducer motor. With an Annual Fuel Utilization Efficiency (AFUE) of up to 96.7%, the Infinity two -stage gas furnace provides exceptional savings when compared to a standard furnace. This Infinity Gas Furnace also features 4-way multipoise installation flexibility, and is available in five model sizes. The 59TN6B can be vented for direct vent/two-pipe, ventilated combustion air, or single -pipe applications. A Carrier Infinity Control and Infinity Air Conditioner or Heat Pump can be used to form a complete Infinity System. All sizes can be installed in air quality management districts with a 40 ng/3 NOx emissions requirement. All sizes are design certified in Canada. INFINITY' i �ESIBy CEQ� cFA Use of the AHRI Certified TM Mark indicates a manufacturer's participation in the program. For ISO 9001 verification of certification for in- dividual products, go to Quality www,ahridirectory.org . A200620 INSTALLATION FLEXIBILITY 4-way multipoise design for upflow, downflow or horizontal installation, with unique vent elbow and optional through- the -cabinet downflow venting capability. Ideal height 35-in. (889 mm) cabinet: short enough for taller coils, but still allows enough room for service. Direct-vent/sealed combustion, single -pipe venting or ventilated combustion air. APPLICATIONS • Self -diagnostics and extended diagnostic data through the Advanced Product Monitor (APM) accessory or Infinity User Interface. • Propane convertible with gas conversion accessory • Convenient Air Purifier and Humidifier connections. • Compatible with single- and multiple -zone Infinity systems. CERTIFICATIONS All sizes meet ENERGY STAR® Version 4.1 criteria for gas furnaces: 95%+ AFUE. Cabinet air leakage less than 2.0% at 1.0 in. W.C. and cabinet air leakage less than 1.4% at 0.5 in. W.C. when tested in accordance with ASHRAE standard 193. 59TN613: Product Data SPECIFICATIONS The furnace should be sized to provide 100 percent of the design heating load requirement plus any margin that occurs because of furnace model size capacity increments. None of the furnace model sizes can be used if the heating load is 20,000 BTU or lower. Use Air Conditioning Contractors of America (Manual J and S); American Society of Heating, Refrigerating, and Air -Conditioning Engineers; or other approved engineering method to calculate heating load estimates and select the furnace. Excessive oversizing of the furnace may cause the furnace and/or vent to fail prematurely, customer discomfort and/or vent freezing. Failure to follow these guidelines is considered faulty installation and/or misapplicat I pf the furnace; and resulting failure, damage, or repairs may impact warranty coverage. FURNACE SIZE 06OC17-14 08OC17-14 08OC21-20 10OC21-22 120C24- 22 HEATING CAPACITY AND EFFICIENCY High Heat (BTUH) 60,000 80,000 80,000 100,000 120,000 Input Low Heat (BTUH) 39.000 52,000 52,000 65,000 78,000 High Heat (BTUH) 58,000 78,000 78,000 98,000 117,000 Output Low Heat (BTUH) 38,000 50,000 51,000 63,000 76,000 Certified Temperature High Heat 35 - 65 (19 - 36) 40 - 70 (22 - 39) 40 - 70 (22 - 39) 45 - 75 (25 - 42) 45 - 75 (25 - 42) Rise Range OF (°C) Low Heat 30 - 60 (17 - 33) 30 - 60 (17 - 33) 30 - 60 (17 - 33) 30 - 60 (17 - 33) 30 - 60 (17 - 33) AIRFLOW CAPACITY AND SLOWER DATA Rated External Static Pressure (in. w.c.) Heating 0.12 0.15 0.15 0.20 0.20 Cooling 0.50 0.50 0.50 0.50 0.50 Airflow Delivery @ Rated ESP (CFM) High Heat 1055 1240 1345 1575 1820 Low Heat 755 1008 1095 1365 1555 Coding 1280 1310 1945 2160 2135 Cooling Capacity (tons) 400 CFMlton 3 3.50 4.50 5 5.50 350 CFM/ton 3.50 4 5.50 6 6 Direct -Drive Motor Type Electronically Commutated Motor (ECM) Direct -Drive Motor HP 1/2 1/2 1 1 1 Motor Full Load Amps 8.50 8.50 12.80 12.80 12.80 RPM Range 300 -1300 Speed Selections Variable (Communicating) Blower Wheel Dia x Width in. 11 x 8 11 x 8 I 11 x10 1 11 x 10 11 x 11 Air Filtration System Factory Supplied Extemal Media Cabinet Field Supplied Filter Filter Used for Certified Watt Data* 325531-20 ELECTRICAL DATA Input Voltage Vohs -Hertz -Phase 115-60-1 Operating Voltage Range Min -Max 104-127 Maximum Input Amps Amps 9.30 9.30 13.60 13.70 13.70 Unit Ampacity Amps 12.60 12,60 17.90 18.00 18.00 Minimum Wire Size AWG 14 14 12 12 12 Maximum Wire Length @ Minimum Wire Size Feet 29 29 32 31 31 (M) (9.0) (9.0) (9.8) (9.7) (9.7) Maximum Fuse/Ckt Bkr (Time -Delay Type Recommended) Amps 15 15 20 20 20 Transformer Capacity (24vac output) 40 VA Extemal Control Power Available Heating 24.3 VA Coding 34.6 VA CONTROLS Gas Connection Size 1/2" - NPT Burners (Monoport) 3 4 1 4 5 1 6 Gas Valve (Redundant) Manufacturer White Rogers Minimum Inlet Gas pressure (in. we) 4.50 Maximum Inlet Gas pressure (in. wc) 13.60 Manufactured (Mobile) Home Kit Not approved for Modular {Mobile Home) use Ignition Device Sificon Nitride Heating Blower Control (Heating Off -Delay) Adjustable: 90, 120, 150, 180 seconds Cooling Blower Control (Time Delay Relay) 90 seconds Communication System Infinity; Infinity Zoning Thermostat Connections R, W/W1, W2 Y/Y2, Y1, G, Com 24V, DHUM Accessory Connections EAC (115vac); HUM (24vac); 1-stg AC (via Y/Y2) •. See Accessory List for part numbers available Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 3