BLD2022-0924_Site_Plan_7.13.2022_12.56.40_PM_2987246
GENERAL NOTES 1. All electrical materials shall be new and listed by recognized electrical testing laboratory Custom made equipment shall have complete test data submitted by the manufacturer attesting to its safety 2. Outdoor equipment shall be NEMA 3R rated or equivalent 3. All metallic equipment shall be grounded 4. Contractor shall obtain electrical permits prior to installation and shall coordinate all inspections, testing commissioning and acceptance with the client, utility co. and city inspectors as needed. 5. The electrical contractor shall verify the exact locations of service points and service sizes with the serving utility company and comply with all utility companies requirements. 6. Drawings are diagrammatic only, routing of raceways shall be option of the contractor unless otherwise noted and shall be coordinated with other trades. 7. If the roof material or the roof structure not adequate for PV installation, call the engineer of record print to installation. The contractor is responsible to verify that the roof is capable of withstanding the extra weight. 8. If the distances for cable runs are different than shown, the contractor shall notify the electrical engineer to validate the wire size. Final drawings will be red -lined and updated as appropriate. 9. Whenever a discrepancy in quality of equipment arises on the drawing or specifications, the contractor shall be responsible for providing and installing all materials and services required by the strictest conditions noted on the drawings or in the specifications to ensure complete compliance and longevity of the operable system required by the engineer of record. PHOTOVOLTAIC NOTES: 1. Rooftop mounted photovoltaic panels and modules shall be tested, listed and identified by recognized testing laboratory 2. Solar system shall not cover any plumbing or mechanical vents 3. Modules and support structures shall be grounded unless racking has integrated ground. 4. Removal of an interactive inverter or other equipment shall not disconnect the bonding connection between the grounding electrode conductor and the photovoltaic source and/or output circuit grounded conductors. 5. All PV modules and associated equipment and wiring shall be protected from physical damage. 6. Live parts of PV source circuits and PV output circuits over 150v to ground shall not be accessible to other than qualified persons while energized. 7. Inverter is equipped with integrated DC disconnect, thus providing ground fault protection 8. All conductors shall be copper and 75 deg rated 9. A single conductor shall be permitted to be used to perform the multiple functions of do grounding, AC grounding and bonding between AC and DC systems. 10. Non -current carrying metal parts of equipment shall be effectively bonded together. Bond both ends of raceways. SHEETINDEX SITE MAP & PV LAYOUT ELECTRICAL 1-LINE DIAGRAM SYSTEM LABELING DETAIL PROPERTY PLAN ATTACHMENT LAYOUT INVERTER DATA SHEET_ RSD DATA SHEET MODULE DATA SHEET RACKING DATA SHEET_ ATTACHMENT DATA SHEET ECB DATA SHEET GOVERNING CODES PV 1.0 PV 2.0 PV 3.0 PV 4.0 PV 5.0 D 6.0 D 7.0 D 8.0 D 9.0 D 10.0 D 11.0 THE INSTALLATION OF SOLAR ARRAYS AND PHOTOVOLTAIC POWER SYSTEMS SHALL COMPLY WITH THE FOLLOWING CODES: • 2015 National Electrical Code • 2015 International Residential Code • 2015 International Building Code • 2015 Mechanical Code • 2015 International Fire Code • 2015 International Energy Conservation Code AS ADOPTED BY THE STATE OF WASHINGTON ALL OTHER ORDINANCE ADOPTED BY THE LOCAL GOVERNING AGENCIES SYSTEM RATING DC 15.600KW STC AC 13.995KW STC EQUIPMENT SUMMARY 39 SOLARIA 400 WATT MODULES WITH IQ8M MICROINVERTERS ELECTRICAL INFORMATION EXISTING MAIN SERVICE PANEL BUS SIZE:225A MAIN SERVICE BREAKER SIZE:200A MOUNTING SYSTEN IRONRIDGE BUILDING INFORMATION TWO STORY HOUSE CONSTRUCTION TYPE: V-B OCCUPANCY: R3 ROOF: COMP. SHINGLE Truss 2 x 4 @ 24" O.C. CONTRACTOR Northwest Electric and Solar Address: 18001 73rd Ave NE Kenmore WA 98028 Phone number: 206-356-0601 Appointments: nwsolar.com Owner: Property Address: Property Type: _ Drawn by: Date: VICINITY MAP (SCALE: NTS 4900 Schneider 218th St SW Edmonds, WA 98026 Single Family Residence New@engineerinc.io 0711312022 9 3 Stsw 2181hStSW 218thStSW T ztatlistSi^! D m f 8th Brook and Com anQ •SW, Edmonds, WA.- A Holloway Habitats Gardening O SATELLITE VIEW (SCALE: NTS) A No° INDEX W vo iel er er ct )x er ile ait ie SOLAR MODULES 39 Solaria 400 Watt Model #PowerXT-400R-PM IAI\/CDTCD INVERTER TYPE: Micro: 39 Enphase IQ8M Model # IQ8M-72-2-US(240V) Total Roof Area: 3960 Total Module Area: 702 17.72% of Coverage CONTRACTOR Northwest Electric and Solar Address: 18001 73rd Ave NE Kenmore WA 98028 Phone number: 206-356-0601 Appointments: nwsolar.com SITE MAP & PV LAYOUT CNGINCCZINC Drawn by. New@engineerinc.io DATE: 0711312022 Project Name: 4900 Schneider Property Adress: 8508 218th St SW Edmonds, WA 98026 Project: Scale: PV SYSTEM AS INDICATED F-PV 1.0 ENPHASE Q CABLE (2) #12 AWG PV WIRE (1) #6 AWG EGC Q Sup■ •u�■ .......... SuL� = r ■■ass■ •■■■• among m ■■■■■■ •■■■• •■■■� U r1,iiii F2,iiii .......... a3 Mae m i ❑+ ■ _ woman U - ■■■■■ Q C) ����� Of � •oma• C° v rams■ L1�■■■ Q ■ ❑+ iL's •aael 11111111 Nasal ■aee� in Emmons mCO. F _ n■ an U H 90 masson m �U inin ❑+ ❑+ ❑+ 0 FL Of U •oma• seem■ ■Eee• U N1,Iii 2,iiii r:,iii m ❑+ ■ ❑+ .......... Im ❑+ -massNasal a' Uso ■wawa■ •eEE• •aWeg ::::: no PM: m � SSgo S:• ■S■■■ ■aee�71 NOTE: Service Panel does not contain center fed Main Breaker: (2) #10 AWG THWN/THWN-2 (1) #8 AWG GND J BOX 3/4" EMT 16 FEET NEMA3 EXISTING NON CENTER 200A MAIN C/B PV MONITORING DEVICE 15A 2-POLE If 2 #14 AWG THWN/ THWN-2 100A NON FUSED AC DISCONNECT LOCKABLE,BLADE TYPE, INSTALL (4)20A PV =_ NEMA3R �� EXISTING 2-POLE C/B 120 / 240V 225A MAIN (UTILITY REQUIRED) INSTALL 70A 2P CB(PV) SERVICE (8) #10 AWG THWN/THWN-2 INSTALL AT OPPOSITE PANEL (1) #8 AWG GND END OF BUS FROM �� 120/240V, 3/4" EMT 12 FEET MAIN FEEDER CB 1P, 3W n J BOX NEMA3 REEEM (6) #10 AWG THWN/THWN-2 ENPHASE IQ COMBINER 4/4C °o (1) #8 AWG GND 120/240V, NEMA 3R 3/4" EMT 10 FEET 3 #6 AWG THWN/THWN-2 ( ) (6) #10 AWG THWN/THWN-2 (1) #8 AWG GND 3/4" EMT 2 FEET GEC (1) #8 AWG GND ELECRTRODEING SYSTEM - 3/4" EMT 19 FEET (3) #6 AWG THWN/THWN-2 ® (6) #10 AWG THWN/THWN-2 (1) #8 AWG GND J BOX (1) #8 AWG GND 3/4" EMT 2 FEET NEMA3 3/4" EMT 12 FEET ) #10 AWG THWN/THWN-2 r ) #8 AWG GND JI JI U■ 2 rmamma ■ .......... swoon ■ - - Sae■■n' Nasal Q ■a■■• •NEE■ •EWNE■ � U ■EEm■ ■SEE■ ■EWES■ m coma• •emm■ ■ass■■ J BOX NEMA3 ■ ❑+ j ❑+ ■ ❑+ ■ .......... U a■■■■■ mason •aeon■ z - aw■as■ •eEE• •anew• U ■■Swam ■■NEE ■••EE• m Of ■■■■■■ S■■■■ ■mwww� U LiJaaao 2�soon .......... r::g 39 SOLARIA 400 WATT MODULES 39 ENPHASE IQ8M MICROINVERTERS MAIN METER PV ARRAY RATING WIRE SIZE CALCULATION BRANCH CIRCUIT -A BRANCH CIRCUIT -A Number Modules 10 PowerXT-400R-PM Solaria 400 Watt Number OF Microinverters in Circuit 10 Number Microinverters 10 Enphase IQ8M Microinverters IQ8M-72-2-US(240V) Microinverter Maximum Output Current (A) 1.35 Total DC Wattage (Watts) Watts STC, (Watts/Module) 10 * 400 = 4000 Branch Circuit Total Current (A) 10 * 1.35 * 1.25 =16.87 Array Currents 1-SC 9.82 A 1-MP 9.41 A Breaker Size Per Branch Circuit (A) 20 Module Voltage V-OC 1 51.1 IV V-MP 1 42.4 IV BRANCH CIRCUIT -B BRANCH CIRCUIT - B Number Modules 10 1 1 PowerXT-40OR-PM I Solaria 400 Watt Number OF Microinverters in Circuit 10 Number Microinverters 10 1 1 Enphase IQ8M Microinverters I IQ8M-72-2-US(240V) Microinverter Maximum Output Current (A) 1.35 Total DC Wattage (Watts) Watts STC, (Watts/Module) 10 * 400 = 4000 Branch Circuit Total Current (A) 10 * 1.35 * 1.25 =16.87 Array Currents 1-SC 9.82 A I -MP 9.41 A Breaker Size Per Branch Circuit (A) 20 Module Voltage V-OC 51.1 V V-MP 42.4 V BRANCH CIRCUIT - C BRANCH CIRCUIT - C Number Modules 10 PowerXT-400R-PM Solaria 400 Watt Number OF Microinverters in Circuit 10 Number Microinverters 10 1 Enphase IQ8M Microinverters IQ8M-72-2-US(240V) Microinverter Maximum Output Current (A) 1.35 Total DC Wattage (Watts) Watts STC, (Watts/Module) 10 * 400 = 4000 Branch Circuit Total Current (A) 10 * 1.35 * 1.25 =16.87 Array Currents 1-SC 9.82 A 1-MP 1 9.41 A Breaker Size Per Branch Circuit (A) 20 Module Voltage V-OC 51.1 V V-MP 42.4 V BRANCH CIRCUIT - D BRANCH CIRCUIT - D Number Modules 9 PowerXT-400R-PM I Solaria 400 Watt Number OF Microinverters in Circuit 9 Number Microinverters 9 Enphase IQ8M Microinverters I IQ8M-72-2-US(240V) Microinverter Maximum Output Current (A) 1.35 Total DC Wattage (Watts) Watts STC, (Watts/Module) 9 * 400 = 3600 Branch Circuit Total Current (A) 9 * 1.35 * 1.25 =15.18 Array Currents 1-SC 9.82 A 1-MP 9.41 A Breaker Size Per Branch Circuit (A) 20 Module Voltage V-OC 51.1 1 V V-MP 42.4 V FROM JBOX TO ENPHASE IQ COMBINER Maximum Continuous Current (A) 16.87 More Than 3 CCC Adjustment Factor 0.7 Adjusted ConductorAmpacity(A) 16.87 / 0.7 = 24.1 Raceway Height From Roof (Temp 39+22=61C) 31/2" # of wire(# BC *2) 8 Ambient Temp Factor Per NEC Table 310.15(b)(2)(a) 0.71 Temp. Derate Factor (max. Continuous current divided ambient tem. Factor (A) 24.1 / 0.71 = 33.94 wire Size from NEC Table 310.15(b)16 10 AWG FROM ENPHASE IQ COMBINER TO MAIN PANEL Total Number Of Microinverters 39 Total Amps From All Microinverters (A) 39 * 1.35 = 52.65 Consider Continuous (A) 52.65 * 1.25 = 65.81 Temp. Derate Factor(0.91 at wall of the Building) (A) 65.81 / 0.91= 72.32 Wire Size from NEC Table 310.15(b)16 6 AWG Ambient Temp Factor Per NEC Table 310.15(b)(2)(a) 0.91 MAIN SERVICE PANEL PV Backfeed Breaker Size (A) 1 70 1 Main Breaker (A) 200 Main Bus Rating (A) 1225 Total Amps On Bus (A) 120% 200 + 70 = 270 1 <= 270(A) CONTRACTOR Northwest Electric and Solar Address: 18001 73rd Ave NE Kenmore WA 98028 Phone number: 206-356-0601 Appointments: nwsolar.com Northwest & Solar ELECTRICAL 1-LINE DIAGRAM CNGINCC�INC Drawn by: New@engineerinc.io DATE: 07/ 1312022 Project Name: 4900 Schneider Property Adress: 8508 218th St SW Edmonds, WA 98026 Project: Scale: PV SYSTEM AS INDICATED PV 2.0 LABEL 1 LABEL 2 LABEL 3 LABEL 4 LABEL 5 LABEL 6 LABEL 7 (STICKER TO BE LOCATED ON CONDUIT WITH DC CURRENT EVERY 4' HORIZONTALLY OR 10' VERTICALLY AND V FROM EACH SIDE OF A BEND) LABEL 8 LABEL 9 (STICKER LOCATED (STICKER LOCATED INSIDE PANEL INSIDE PANEL NEXT TO SOLAR BREAKER) BELOW PV BREAKER) DIRECTORY LABEL 10 (STICKER LOCATED ON THE PV SUB PANEL) (TO BE LOCATED ON SUB -PANEL ONLY WHEN SUB -PANEL IS DEDICATED FOR PV ONLY) LABEL 11 (STICKER LOCATED ON THE MAIN SERVICE PANEL) LABEL 12 SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY Permanent directory or plaque providing location of service disconnecting means and photovoltaic system disconnecting means, if not located at the same location. (Plaques shall be metal or plastic, with engraved or machine printed letters, or electro-photo plating, in a contrasting color to the plaque. Plaques shall be permanently attached to the equipmenq or in the required location using an approved method that is suitable to withstand the environment to which it is exposed. Plaques and signage shall meet legibility, defacemet, exposure and adhesion requirements of Underwriters Laboratories marking and labeling system 969(UL969). Plaques will have red background & white lettering. INVERTER *if applicable METER 2 © © SUB -PANEL MAIN SERVICE PV SUB -PANEL * if applicable AC PANEL INTEGRATED DISCONNECT 6 7 PV ARRAY J BOX DC DISCONNECT O pplicable © O * if applicable 11 O ® 8 ®O © ® O MARKINGS, LABELS AND WIRING SIGNS A. Purpose: Provide emergency responders with appropriate warning and guidance with respect to isolating solar electric system. This can facilitate identifying energized electrical lines that connect solar panels to the inverter, as these should not be cut when venting for smoke removal B. Main Service Disconnect. 1. Residential buildings - The marking main be placed within the main service disconnect. The marking shall be placed outside cover if the main service disconnect is operable with the service panel closed. 2. Commercial buildings - Tha marking shall be placed adjacent to the main service disconnect clearly visible from the location where the level is operated 3. Markings: Verbiage, Format and Type of Material. a. Verbiage: CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED b. Format: White lettering on a red background. Minimum 3/8 inches letter height. All letters shall be capitalized. Arial or similar font, non bold. c. Material: Reflective, weather resistant material suitable for the environment (use UL - 969 as standard for weather rating). Durable adhesive materials meet this requirement. C.Marking Requirements on DC conduit, raceways, enclosures, cable assemblies, DC combiners and junction boxes: 1. Markings: Verbiage, Format and Type of Material. a. Placement : Markings shall be placed every 10 feet on all interior and exterior DC conduits, raceways, enclosures, and cable assemblies, at turns, above and for below penetrations, all DC combiners and junction boxes b. Verbiage: CAUTION: SOLAR CIRCUIT Note: The format and type of material shall adhere to W. V-3b, c" of this requirement. c. Inverters are not required to have caution markings 1.Marking is required on all interior and exterior DC conduit raceways,enclosures,cable assemblies,and junction boxes,combiner boxes and disconnects. 2.The materials used for marking shall be reflective,weather resistant material suitable for the environment. Minimum 3/8 "letter height; all upper case letters Arial or similar font; Red background with white lettering. 3.Marcking shall contain the words: WARNING: PHOTOVOLTAIC POWER SOURCE. 4.Marking shall be placed adjacent to the main service disconnect in a location clearly visible from the location where the disconnect is operated CONTRACTOR Northwest Electric and Solar Address: 18001 73rd Ave NE Kenmore WA 98028 Phone number: 206-356-0601 Appointments: nwsolar.com & Solar SYSTEM LABELING DETAIL CNGINCCZINC Drawn by: New@engineerinc.io DATE: 0711312022 Project Name: 4900 Schneider Property Adress: 8508 218th St SW Edmonds, WA 98026 Project: Scale: PV SYSTEM AS INDICATED F_PV 3.0 N 0° W 270 E 90 o SCALE: 1 /16" = 1'-0" M Vim' e � . - PROPERTY LINE Dri w —9r-1.. I ECB 103'-9" AC MM I MSP 218th St SW 81'-1 " W MSP................ Main Service Panel MM .............................. Main Meter ECB........... Enphase IQ Combiner AC ........................ AC Disconnect CONTRACTOR Northwest Electric and Solar Address: 18001 73rd Ave NE Kenmore WA 98028 Phone number: 206-356-0601 Appointments: nwsolar.com Northwest Electric & Solar PROPERTY PLAN CNGINCCZINC Drawn by: New@engineerinc.io DATE: 0711312022 Project Name: 4900 Schneider Property Adress: 8508 218th St SW Edmonds, WA 98026 Project: Scale: PV SYSTEM AS INDICATED F-PV 4.0 Solar Attachme MODULES ON ROOF Truss 2 x 4 @ 24" O.C. Plywood & Building Fe n 1 Layer of COMP. SHINGLE In11 IocKing D F#2 2 x 6 ATTACHMENT RAIL Truss 2 x 4 @ 24" O.C. IRONRIDGE ATTACHMENT AND RACKING DETAILS 3. 6��1.02 3. 7 IRONRIDGEIRONRIDGE STOPPER SLEEVE j-4.50—I IASTENI G UNIVERSAL PV MODULE �9 UJ FASTENING OBJECT ^^ IRONRIDGE UNIVERSAL t`I ,—IRONRIDGE RAIL n FASTENING OBJECT (E) RAFTERS SIDE VIEW 5/16" STAINLESS STEEL LAG SCREW —IRONRIDGE FLASHFOOT2 IRONRIDGE RAIL IRONRIDGE FLASHFOOT2 PV MODULE, BY OTHERS IRONRIDGE RAIL (E) ROOF MEMBRANE IRONRIDGE FLASHFOOT2 (E) BUILDING STRUCTURE PV MODULE, BY OTHERS IRONRIDGE RAIL (E) ROOF MEMBRANE IRONRIDGE FLASHFOOT2 (E) BUILDING STRUCTURE A DETAIL FLASHFOOT2 SIDE 0-DETAIL FLASHFOOT2 FRONT IRONRIDGE UNIVERSALeSUEEVE IRONRIDGE RAIL IRONRIDGE STOPPER SLEE\ PV MODULE FRAME FASTENING OBJECT IRONRIDGE UNIVERSAL IRONRIDGE UNIVERSAL MODULE FRAME FASTENINGOBJECT FASTENING OB]ER PV MODULE FRAMEONRIDGE UNNERSAL PV MODULE FRAME IRONRIDGE RAILSTENING OBJECTIRONRIDGE STOPPE IRONRIDGE RAIL �Ir C DETAIL MID CLAMP PIN C DETAIL MID CLAMP FRONT B DETAIL END CLAMP PLAN B DETAIL END CLAMP FRONT DESIGN CRITERIA POINT LOAD CALCULATION PER ARRAY Modules: 39 Module Weight (Ibs) 46 Max Distributed Load: 3 PSF # Of Modules 39 Total Module Weight (Ibs) 1794 Rack Weight (Ibs) 358.8 Microlnverters Weight (Ibs) 92.82 Total System Weight (Ibs) 2245.62 # Of Standoffs 135 Max Span Between Standoffs (in) 48 Loading Per Standoff (Ibs) 16.63 Total Area (sq.ft.) 702 Loading (PSF) 3.19 Prior to the commencement of work, the contractor shall verify the existing roof and framing conditions. Notify New@engineerinc.io of any Discrepancies prior to starting construction. Prior to the commencement of work, the contractor shall inspect framing for any damage such as water damage, cracked framing, etc. and notify New@engineerinc.io if any issues are found. These Plans are stamped for structural code compliance of the roof framing supporting the proposed PV installation reference only. These plans are not stamped for water leakage. PV modules, racking, and attachment components must follow manufacturer guidelines and requirements. Attachments to be installed in a staggered orientation to properly distribute loads. CONTRACTOR Northwest Electric and Solar Address: 18001 73rd Ave NE Kenmore WA 98028 Phone number: 206-356-0601 Appointments: nwsolar.com Northwest lar ATTACHMENT LAYOUT � CNGINCCZINC Drawn by. New@engineerinc.io DATE: 0711312022 Project Name: 4900 Schneider Property Adress: 8508 218th St SW Edmonds, WA 98026 Project: Scale: PV SYSTEM AS INDICATED F-PV 5.0 n ENPHASE IQ8 Series Microinverters Our newest I08 Microinverters are the industry's first microgrid-forming, software - defined microinverters with split -phase power conversion capability to convert DC power to AC power efficiently. The brain of the semiconductor -based microinverter is our proprietary application -specific integrated circuit (ASIC) which enables the microinverter to operate in grid -tied or off -grid modes. This chip is built in advanced 55nm technology with high speed digital logic and has super -fast response times to changing loads and grid events, alleviating constraints on battery sizing for home energy systems. I I Part of the Enphase Energy System, I08 Series Microinverters integrate with the Enphase 10 Battery, Enphase IQ Gateway. and the Enphase App monitoring and analysis software. wmc Connect PV modules quickly and easily to 108 Series Microinverters using the included Q-DCC-2 adapter cable with plug-n-play MC4 connectors. I08 Series Microinverters redefine reliability standards with more than one million cumulative hours of power -on testing. enabling an industry -leading limited warranty of up to 25 years. I08 Series Microinverters are UL Listed as PV Rapid Shut Down Equipment and conform with various regulations, when installed according to manufacturer's instructions. 0 2022 Enphase Energy. All rights reserved. Enphase. the Enphase logo. I08 microinverters. and other names are trademarks of Enphase Energy. Inc. Data subject to change. IQ8SE-DS-0001-01-EN-US-2022-03-01 Easy to install Lightweight and compact with plug-n-play connectors Power Line Communication (PLC) between components Faster installation with simple two -wire cabling High productivity and reliability Produce power even when the grid is down More than one million cumulative hours of testing Class II double -insulated enclosure Optimized for the latest high- powered PV modules Microgrid-forming Complies with the latest advanced grid support Remote automatic updates for the latest grid requirements Configurable to support a wide range of grid profiles Meets CA Rule 21(ILL 1741-SA) requirements 1,08 Series Microinverters Commonly used module pairings' w 235 - 350 235 - 440 260 - 460 295 - 500 320 - 540• 295 - 500+ Module compatibility 60-cell/120 half -cell 60-cell/120 half -cell. 66-cell/132 half -cell and 72-cell/144 half -cell MPPT voltage range V 27-37 29-45 33-45 36-45 38-45 38-45 Operating range V 25 - 48 25 - 58 Min/max start voltage V 30 / 48 30 / 58 Max input DC voltage V 50 60 Max DC current' [module Isc] A 15 Overvoltage class DC port II DC port backfeed current mA 0 PV array configuration 1xl Ungrounded array: No additional DC side protection required: AC side protection requires max 20A per branch circuit Peak output power VA 245 300 330 366 384 366 Max continuous output power VA 240 290 325 349 380 360 Nominal (L-L) voltage/range' V 240 / 211- 264 208 / 183 - 250 Max continuous output current A 1.0 1.21 1.35 1.45 1.58 1.73 Nominal frequency Hz 60 Extended frequency range Hz 50 - 68 Max units per 20 A (L-L) branch circuit° 16 13 11 11 10 9 Total harmonic distortion <5% Overvoltage class AC port III AC port backfeed current mA 30 Power factor setting 1.0 Grid -tied power factor (adjustable) 0.85leading - 0.85lagging Peak efficiency % 97.5 97.6 97.6 97.6 97.6 97.4 CEC weighted efficiency % 97 97 97 97.5 97 97 Night-time power consumption raw 60 MECHANICAL DATA Ambient temperature range -400C to+60°C (-40°F to+140°F) Relative humidity range 4%to 100%(condensing) DC Connector type MC4 Dimensions (HxWxD) 212 man (8.3") x 175 mm (6.9") x 30.2 man (1.2") Weight 1.08 kg (2.38lbs) Cooling Natural convection - no fans Approved for wet locations Yes Acoustic noise at 1 m <60 dBA Pollution degree PD3 Enclosure Class II double -insulated. corrosion resistant polymeric enclosure Environ. category / UV exposure rating NEMA Type 6 / outdoor CA Rule 21(UL 1741-SA). UL 62109-1. UL1741/IEEE1547. FCC Part 15 Class B. ICES-0003 Class B. CAN/CSA-C22.2 NO.107.1-01 Certifications This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014. NEC 2017. and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems. for AC and DC conductors. when installed according to manufacturer's instructions. (1) The IQBH-208 variant will be operating in grid -tied mode only at 208V AC. (2) No enforced DC/AC ratio. See the compatibility calculator at https://Iink.enphase.com/module-compatibility (3) Maximum continuous input DC current is 10.6A (4) Nominal voltage range can be extended beyond nominal if required by the utility. (5) Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. IQ8SE-DS-0001-01-EN-US-2022-03-01 CONTRACTOR Northwest Electric and Solar Address: 18001 73rd Ave NE i Kenmore WA 98028 Phone number: 206-356-0601 Appointments: nwsolar.com SolarNorthwest Electric INVERTER DATA SHEET CNGINCCZINC Drawn by: New@engineerinc.io DATE: 0711312022 Project Name: 4900 Schneider Property Adress: 8508 218th St SW Edmonds, WA 98026 Project: Scale: PV SYSTEM AS INDICATED D 6.0 Enphase• Energy // Rapid Shutdown Rapid shutdown is built-in The 2014 edition of the National Electrical Code (NEC 2014) added What's new in NEC 2014? new rapid shutdown requirements for PV systems installed on buildings. WEC =014. 0ectfon 600.12 app ' Enphase Microinverters fully meet rapid shutdown requirements in the to PV conductor; mw 10 fetid from new code without the need to install any additional electrical equipment. ft PV array and requaeG mx the conductor power down to 30 volt -- and 240 vok-an:psm within 10 uconds of rqD d shutdown initiaaort String inverters require work arounds for rapid shutdown Work around. pecialcsd Rapid ShuWao eiectncal box ins-iAed on tl roof w ahin 10 feet of array. Work around. c tutof. nv;"ch that is ea *?y accG- d3v to brct rcxponderr on the ground Worst around. Extra conduit in trY,(1azor Residential String Inverter Work around. ,7,rp ;nvSr,Qr lmtalied on roof, a hoctde envaonrnem mat =ng irwarterr amps not bull to liva in Commercial String Inverter Enphase comes standard with rapid shutdown capability All Enphwe microei- verters, won those thm were preV*urly inaaftd. inherontty nrtw. rapid shutdown requrwriontc-, no additional equiprnam or workzroundr needed Residential Microinverter To learn more, visit enphase.com Enphase rrocroinver&m can ;al* rhtR down a6aamatically, ki,,wng only to w mitage DC BieGticity iniamd! M the PV module Commercial Microinveortgr [e] enphase- ENPHASE. Install the Enphase IQ8 Series Microinverter To install Enphase IQ8 Series Microinverters, read and follow all warnings and instructions in this guide and in the Enphase I08 Series Microinverter Installation and Operation Manual at ennhase_com/support Safety warnings are listed on the back page of this guide. The Enphase Microinverter models listed in this guide do not require grounding electrode conductors (GEC), equipment grounding conductors (EGC), or grounded conductor (neutral). The microinverter has a Class II double -insulated rating, which includes ground fault protection (GFP). To support GFP, use only PV modules equipped with DC cables labeled PV Wire or PV Cable IMPORTANT: Enphase IQ8 Series Microinverters require the IQ Cable. An IQ Gateway is required to monitor performance of the IQ Microinverters. The Q Accessories work only with Enphase IQ8 Series Microinverters. Note: After you log in to your Enphase Installer Platform account from Enphase Installer app, Scan the microinverter QR code and connect to the Enphase IQ Gateway to track the system installation progress. PREPARATION A ) Download the Enphase Installer App and open it to log in to your Enphase Installer Platform account. With this Or ❑� app, scan the microinverter QR code and connect to the Enphase IQ Gateway to track system installation progress. To download, go to enichase com/toolkit or scan the QR code at right B) Refer to the following table and check PV module electrical compati- bility at: enphase com/en-us/sunnoLt/module-compalbAily- model DC connector Typical PV module* cell count IQ8-60-2-US MC-4 locking type Pair with 60 cell /120-half-cell modules MC-4 locking type Pair with 60 cell / 120-half-cell, 66 cell, or 72 cell / 144-half--cell 18%72-2-US IQSA-72-2-US IQSH-240-72-2-US IQ814-208-72-2-US MC-4 locking type Pair with 60 cell /120-half-cell, 66 cell, or72 cell / 144-half--cell * Enphase IQ8 Series Microinverters are compatible with bi-facial PV modules if the temperature adjusted electrical parameters (maximum power, voltage and current) ofthe modules, considering the front side electrical parameters (i.e., (A back side gain), are within the allowable rrdcroinverter input parameters range C) In addition to the Enphase Microinverters, PV modules and racking, you will need these Enphase IQ8 Series Microinverters: Enphase IQ Gateway (model ENV-IQ-AM1-240) communications gateway or Enphase IQ Combiner (check enphase.com for models): is required to monitor solar production. Tie wraps or cable clips (Q-CU P-100) Enphase Sealing Caps (Q-SEAL-10): for any unused connectors on the Enphase IQ Cable Enphase Terminator (Q-TERM-10): one needed at the end of each AC cable segment Enphase Disconnect Tool (Q-DISC-10) Enphase IQ Cable: Cable model Connector spacing* PV module orientation Connectors per box 0-12-10-240 1.3m Portrait (all) 240 Q-12-17-240 2.0m Landscape (60- and 66-cell) 240 Q-12-20-200 2.3m Landscape(72-cell) 200 *Allows for 30cm of cable slack D) Check that you have these other items: ACjunction box. Tools: screwdrivers, wire cutter, voltmeter, torque wrench, sockets, and wrenches for mounting hardware E) Protect your system with lightning and/or surge suppression devices. It is also important to have insurance that protects against lightning and electrical surges. F) Plan your AC branch circuits to meet the following limits for maximum number of microinverters per branch when protected with a 20amp over -current protection device (OCPD). Maximum* IQ8 Series Microinverters per AC branch circuit (sin- gle-phase) IQ8(240V) IQ8+ (240V) IQ8M (240V) 16 13 11 IQSA (240V) IQ8H (240V) IQ8H (208V) 11 10 9 * Limits may vary Refer to local requirements to define the number of microinverters per branch in your area. G ) Size the AC wire gauge to account for voltage rise. Select the correct wire size based on the distance from the beginning of the Enphase IQ Cable to the breaker in the load center. Design for a voltage rise total of less than 2°i for these sections. Refer to the Voltage Rise Technical Brief at enphase com/support for more information. Best practice: Center -feed the branch circuit to minimize voltage rise in a fully -populated branch. DC connector '*-,Tie wraps or cable clips -- Enphase IQ8 Series Microinverter (horizontal installation shown, vertical installation also allowed). ACjunction box Terminator 601lhase IQ�C.ble \AC connector 0 2021 Enphase Energy. All rights reserved. Enphase, the Enphase logo, Enphase IQ8 Series micranverters (IQ8, IQ8+, IQ8A, IQ8H and Q810), Enphase Installer Platform, Enphase IQ Gateway, and other trademarks or service names are the trademarks of Enphase Energy, Inc. Data subjectto change. Rev02-10-23-2021 III IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII III 140-00195-02 CONTRACTOR Northwest Electric and Solar Address: 18001 73rd Ave NE I Kenmore WA 98028 Phone number: 206-356-0601 Appointments: nwsolar.com Northwest Solar ENPHASE RAPID SHUTDOWN, COMPATIBILITY WITH PV E N G I NE Er"4 I NC Drawn by: New@engineerinc.io DATE: 0711312022 Project Name: 4900 Schneider Property Adress: 8508 218th St SW Edmonds, WA 98026 Project: Scale: PV SYSTEM AS INDICATED FD_ 7.0 SOL R I^ Solaria PowerXT° DC Panel SOL R I^ Solaria PowerXT11-400R-PM CONTRACTOR rrr Solaria PowerXT- 40OR-PM Cell Type Monocrystalline Silicon Max Power (Pmax) [W] 400 Dimensions (L x W x H) 64.72" x 47.4" x 1.57" Efficiency [%J 20.2 1644mm x 1204mm x 40mm Northwest Electric and Solar Open Circuit Voltage (Voc) IV] 51.1 Weight 21 kg / 46lbs Address: 18001 73rd Ave NE Short Circuit Current (Ise) [A] 9.82 Glass Type /Thickness AR Coated, Tempered / 2.84mm Kenmore WA 98028 Max Power Voltage(Vmp) [V] 42.4 Frame Type Black Anodized Aluminum Phone number: 206-356-0601 Solaria .rXT„ Max Power Current (Imp) [A] 9.41 Cable Type / Length 12 AWG PV Wire (UL) / 1000mm Appointments: nwsolar.com Power Tolerance [%] -0/+3 Connector Type MC4 Junction Box IP67 / 4 diodes Front Load 5400 Pa / 113 psf* Achieving over 20°k efficiency, Solaria PowerXT solar panels are one of the highest power panels in the residential and commercial solar Max Power (Pmax) [W) 295 Rear Load 2400 Pa / 50 psf* market. Compared to conventional panels, Solaria PowerXT panels have fewer gaps between the solar cells; this leads to higher power Open Circuit Voltage (Voc) IV] 48.1 'Refer to Solari a Installation Manual for detelIs and superior aesthetics. Solaria PowerXT Pure BlackTM panels are manufactured with black backsheet and frames, enhancing a home or Short Circuit Current (Ise) [A] 7.92 Certifications / Warranty building's architectural beauty. Max Power Voltage (Vmp) IV] 40.0 Northwest Max Power Current (Imp) [A] 7.59 Certifications UL 61730/UL1741/CEC CAN/CSA-C22.2 Solar TemperatureFire Type (UL 1703) 1 Higher Efficiency, Higher Power NOCT [°C] 45+/.2 Warranty 25 years* Solaria PowerXTpanels achieveover20% efficiency; conventional panels achieve 15%— Temp. Coeff. of Pmax 0 0 [%/ C] -0.39 'warranty details atwww.solaria.com 17°h efficiency. Solaria PowerXT panels are one of the highest power panels available. Temp. Coeff. of Voc [%/ °C] -0.29Temp. •' ' � ' Coeff. of Isc [%/ °CJ 0.04 Stacking Method Horizontal / Palletized Lower System Costs Design Parameters Panels/ Pallet 25 Solaria PowerXT panels produce more power per square meter area. This reduces Operating temperature [°CJ -40 to+85 Pallet Dims (L x W x H) 66.57" x 48.7" x 48.4" 1691 mm x 1238mm x 1230 mm installation costs due to fewer balance of system components. y P Max system Voltage [A] 1000 Pallet Weight 590 kg / 1300 Ibs Max Fuse Rating [p] PO Bypass Diodes [#] 4 Pallets / 40-ft Container 18 Improved Shading Tolerance Panels /40-ftContainer 450 Sub -strings are interconnected in parallel, within each of the four panel quadrants,IV 9 P P q Irradiance r r [r.da [s�n� ta�m� gin" which dramatically lowers the shading losses and boosts energy yield. umm 'gym A S ¢ r Improved Aesthetics 9 Compared to conventional panels, Solaria PowerXT panels have a more uniform appearance and superior aesthetics. Durability and Reliability urwaYr, e�" r .l MODULE Solder -less cell interconnections are highly reliable and designed to far exceed ' DATA SHEET the industry leading 25 year warranty. ° A 6 ! a S 10 IS 2a 1! >D 95 VOLTAGE(V) GO 13 p.on] ts.r� as.an] � dttmm �mm Comprehensive 25-Year Warrantmrmp.z>eMxromroio.lraM mas,mnlatenl About Solaria 1m% 98% 25-year Power, Parts and Labor from Solaria Typical Tier 1 industry warranty Drawn by: New@engineerinc.io DATE. 0711312022 Established in 2000, The Solaria Corporation has created one of the industry's most respected HOC PERFO%, IP portfolios, with over 250 issued and pending patents in PV solar cell and module technology. 2018 Headquartered in Oakland, California, Solaria has developed a technology platform that ® 9a1 to, L — sa% —81% [°s•nm] [. Project Name: 4900 Schneider Property Adresa: DNV•GL Tl1VRhelnlandm] unlocks the potential of solar energy. 8508 218th St SW Pid MODULE RELLABILRY SCORECARO Precisely Right. s io is Years zo zs FRAME PROFILE Edmonds, WA 98026 Project: I Scale: The Solana Corporation 1700 Broadway, Oakland, CA 94612 P: (510) 270-2507 www.solaria.com Copyright ® 2020 The Solaria Corporation The Solaria Corporation 1700 Broadway, Oakland, CA 94612 P (510) 270-2507 www.solarla com ® Copyrght 2020 The Solana Corporation PV SYSTEM AS INDICATED Product specifications are subjectto change without notice. SOL-DAT-0005 Rev 01 4-2020 Product specifications are subject to change without notice. SOL-DAT-0005 Rev 01 4-2020 F-D8.0 Ak IRONRIDGE Flush Mount System XR Rails e XR10 Rail XR100 Rail XR1000 Rail Bonded Splices CONTRACTOR Northwest Electric and Solar L Address: 18001 73rd Ave NE _ I Kenmore WA 98028 T A low -profile mounting rail The ultimate residential A heavyweight mounting All rails use internal splices Phone number: 206-356-0601 for regions with light snow. solar mounting rail. rail for commercial projects. for seamless connections. Appointments: nwsolar.com • 6'spanning capability 8' spanning capability 12' spanning capability Self -drilling screws • Moderate load capability Heavy load capability Extreme load capability Varying versions for rails • Clear and black finish Clear and black finish Clear anodized finish Forms secure bonding Clamps & Grounding UFOs Stopper Sleeves CAMO Grounding Lugs Northwest Electric Solar Universal Fastening Objects Snap onto the UFO to turn Bond modules to rails while Connect arrays to bond modules to rails. into a bonded end clamp. staying completely hidden. equipment ground. • Fully assembled & lubed Bonds modules to rails Universal end -cam clamp Low profile • Single, universal size Sized to match modules Tool -less installation Single tool installation • Clear and black finish Clear and black finish Fully assembled Mounts in any direction Built for solar's toughest roofs. Attachments ® — IronRidge builds the strongest mounting system for pitched roofs in solar. Every component has been tested to the limit and proven in extreme environments. FlashFoot2 Conduit Mount Slotted L-Feet Bonding Hardware Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and is also why our products are fully certified, code compliant and backed by a 25-year warranty. MW `! P=� • Strength Tested PE Certified _ � RACKING All components evaluated for superior Pre -stamped engineering letters Flash and mount XR Rails Flash and mount conduit, Drop -in design for rapid rail Bond and attach XR Rails DATA SHEET StrUCtUral performance. available In most states. with superior waterproofing. strut, or junction boxes. attachment. to roof attachments. • Twist -on Cap eases install Twist -on Cap eases install Secure rail connections T & Square Bolt options Class A Fire Rating Design Assistant • Wind -driven rain tested • Mill and black finish Wind -driven rain tested • Secures 3/4" or 1" conduit Slot for vertical adjusting • Clear and black finish Nut uses 7/16" socket • Assembled and lubricated ENGINEErZINC Certified to maintain the fire resistance !� Online software makes it simple to Resources Drawn by: New@engineerinc.io rating of the existing roof. create, share, and price projects. DATE: 0711312022 UL 2703 Listed System 25-Year Warranty _ Design Assistant Go from rough layout to fully engineered system. For free. ••R� NABCEP Certified Training Earn free continuing education credits, while learning more about our systems. Project Name: 4900 Schneider Propertyndress, Entire system and components meet Products guaranteed to be free %B�CEp 8508 218th St SW newest effective UL 2703 standard. of impairing defects. Go to IronRidge.conVdesign Go to Iron Ridge. con,/training Edmonds, WA 98026 Project: Scale: PV SYSTEM AS INDICATED G .• 90• ..: Othwe Pencing. Vemion 1.70 �/�►�FD 9.0 AOL IRON RIDGE The Strongest Attachment in Solar IronRidge FlashFoot2 raises the bar in solar roof protection. The unique water seal design is both elevated and encapsulated, delivering redundant layers of protection against water intrusion. In addition, the twist -on Cap perfectly aligns the rail attachment with the lag bolt to maximize mechanical strength. Twist -On Cap FlashFoot2's unique Cap design encapsi the lag bolt and locks into place with a sit twist. The Cap helps FlashFoot2 deliver superior structural strength, by aligning the rail and lag bolt in a concentric load path. Single Socket Size A custom -design lag bolt allows you to install FlashFoot2 with the same 7/16" socket size used on other Fkrsh Mount System components. Flash Foot2 Three -Tier Water Seal FlashFoot2's seal architecture utilizes three layers of protection. An elevated platform diverts water away, while a stack of rugged components raises the seal an entire inch. The seal is then fully-encapuslated by the Cap. FlashFoot2 is the first solar attachment to pass the TAS-100 Wind -Driven Rain Test. Water -Shedding Design An elevated platform diverts water away from the water seal. Installation Features B A Alignment Markers Quickly align the flashing with chalk lines to find pilot holes. C B Rounded Corners Makes it easier to handle and insert under the roof shingles. r . C Reinforcement Ribs A t Benefits of Concentric Loading Traditional solar attachments have a horizontal offset between the rail and lag bolt, which introduces leverage on the lag bolt and decreases uplift capacity. FlashFoot2 is the only product to align the rail and lag bolt. This concentric loading design results in a stronger attachment for the system. Testing & Certification Help to stiffen the flashing and prevent any bending or crinkling during installation. 1200 Y.FIsshFoa2 1000 800 u CL 600 M V4-1 400 � 200 0 FlashFoot •Leading Competitor 1 2 Rail -to -Lag Offset (in) Structural Certification Designed and Certified for Compliance with the International Building Code & ASCE/SEI-7. • Lo.-Cost Competitor Water Seal Ratings Water Sealing Tested to UL 441 Section 27 "Rain Test' and TAS 100-95 "Wind Driven Rain Test' by Intertek. Ratings applicable for composition shingle roofs having slopes between 2:12 and 12:12. UL 2703 Conforms to UL 2703 Mechanical and Bonding Requirements. See Flush Mount Install Manual for full ratings. 3 0 2016 IronRidge, Inc. AN rights reserved Ysit www.ironridge.com or call 14800-227-9523 for more information Version 1.0 r� CONTRACTOR Northwest Electric and Solar Address: 18001 73rd Ave NE Kenmore WA 98028 Phone number: 206-356-0601 Appointments: nwsolar.com Northwest Electric & Solar ATTACHMENT DATA SHEET ENGINEEZINC Drawn by: New@engineerinc.io DATE: 0711312022 Project Name: 4900 Schneider Property Adress: 8508 218th St SW Edmonds, WA 98026 Project: I Scale: PV SYSTEM L AS INDICATED F-D 10.0 Data Sheet Enphase Networking Enphase IQ Combiner 4/4C X-IQ-AM1-240-4 X-IQ-AM1-240-4C X-I( SX-IQ-AM1-240 LISTED To learn more about Enphase offerings, visit enohase.com The Enphase IQ Combiner 4/4C with Enphase IQ Gateway and integrated LTE-M1 cell modem (included only with IQ Combiner 4C) consolidates interconnection equipment into a single enclosure and streamlines IQ microinverters and storage installations by providing a consistent, pre -wired solution for residential applications. It offers up to four 2-pole input circuits and Eaton BR series busbar assembly. Smart • Includes IQ Gateway for communication and control • Includes Enphase Mobile Connect cellular modem (CELLMODEM-M1-06-SP-05), included only with IQ Combiner 4C • Includes solar shield to match Enphase IQ Battery aesthetics and deflect heat Flexible networking supports Wi-Fi, Ethernet, or cellular • Optional AC receptacle available for PLC bridge • Provides production metering and consumption monitoring Simple • Centered mounting brackets support single stud mounting • Supports bottom, back and side conduit entry Up to four 2-pole branch circuits for 240 VAC plug-in breakers (not included) • 80A total PV or storage branch circuits Reliable • Durable NRTL-certified NEMA type 3R enclosure Five-year limited warranty Two years labor reimbursement program coverage included for both the IQ Combiner SKU's UL listed ENPHASE Enphase IQ Combiner 4/4C MODEL NUMBER IQCombiner 4 (X-IQ-AM1.240-4) IQ Combiner 4 with Enphase IQ Gateway printed circuit board for integrated revenue grade PV production metering (ANSI C1220+/- 0.5%) and consumption monitoring (+/- 2.5%). Includes a silversolar shield to matchthe IQ Battery system and IQ System Controller 2 and to deflect heat. IQ Combiner 4C (X-IQ-AM1-240-4C) IQ Combiner 4C with Enphase IQ Gateway printed circuit board for integrated revenue grade PV production metering (ANSI C12.20 +/- 0.5%) and consumption monitoring (+/- 2.5`Yo). Includes Enphase Mobile Connect cellular modem (CELLMODEM-M1-06-SP-05), a plug -and -play Industrial -grade cell modem for systems upto 60 microinverters. (Available In the US, Canada, Mexico, Puerto Rico, and the LIS Virgin Islands,where there is adequate cellular service in the installation area.) Includes a silver solar shield to match the IQ Battery and 10 System Controller and to deflect heat. ACCESSORIES AND REPLACEMENT PARTS (not included, order separately) Ensemble Communications Kit Includes COMMS-KIT-01 and CELLMODEM-MI-06-SP-05 with 5-year Sprint data plan for COMMS-CELLMODEM-Ml-06 Ensemble sites CELLMODEM-Ml-06-SP-05 4G based LTE-M1 cellular modem with 5-year Sprint data plan CELLMODEM-Ml-06-AT-05 4G based LTE-M1 cellular modem with 5-year AT&T data plan Circuit Breakers Supports Eaton BR210, BR215, BR220, BR230, BR240, BR250, and OR260 circuit breakers. BRK-10A-2-240V Circuit breaker, 2 pole,10A, Eaton BR210 BRK-15A-2-240V Circuit breaker, 2 pole,l5A, Eaton BR215 BRK-20A-2P-240V Circuit breaker, 2 pole, 20A, Eaton BR220 BRK-15A-2P-240V-B Circuit breaker, 2 pole, l SA, Eaton BR215B with hold down kit support BRK-20A-2P-24OV-B Circuit breaker, 2 pole, 20A, Eaton BR2208with hold down kit support EPLC-01 Power line ca mer (communication bridge pair), quantity- one pair XA-SOLARSHIELD-ES Replacement solar shield for IQ Combiner 4/4C XA-PLUG-120-3 Accessory receptacle for Power Line Carrier in IQ Combiner 4/4C (required for EPLC-01) XA-ENV-PCBA-3 Replacement IQ Gateway printed circuit board (PCB) for Combiner 4/4C X-IQ-NA-HD-125A Hold down kit for Eaton circuit breaker with screws. ELECTRICAL SPECIFICATIONS Rating Continuous duty System voltage 1201240 VAC, 60 Hz Eaton BR series busbar rating 125A Max. continuous current rating 65 A Max. continuous current rating Oniputfrom PV/storage) 64A Max. fuse/circuit rating (output) 90 A Branch circuits (solar and/or storage) Up to four 2-pole Eaton BR series Distributed Generation (DG) breakers only (not included) Max. total branch circuit breaker rating (input) 80A of distributed generation / 95A with IQ Gateway breaker included Production metering CT 200 A solid core pre -installed and wired to IQ Gateway Consumption monitoring CT (CT-200-SPLIT) A pair of 200 A split core current transformers MECHANICAL DATA Dimensions (WxHxD) 37.5 x 49.5 x 16.8 cm (14.75• x 19.5" x 6.63"). Height is 21.06" (53.5 cm) with mounting brackets. Weight 7.5 kg (16.5 Ibs) Ambient temperature range -40° C to+46° C (40° to 115* F) Cooling Natural convection, plus heat shield Enclosure environmental rating Outdoor, NRTLcertified, NEMA type 3R, polycarbonate construction Wire sizes 20 A to 50 A breaker inputs: 14 to 4 AWG copper conductors 60 A breaker branch input: 4 to 1/0 AWG copper conductors Main lug combined output:10 to 2/OAWG copper conductors Neutral and ground: 14 to 1/0 copper conductors Always follow local code requirements for conductor sizing. Altitude To 2000 meters (6,560 feet) INTERNET CONNECTION OPTIONS integrated Wl-R 802.11b/g/n Cellular CELLMODEM-M1-06-SP-05, CELLMODEM-M7-06-AT-05 (4G based LTE-M1 cellular modem). Note that an Enphase Mobile Connect cellular modem is required for all Ensemble installations. Ethernet Optional, 802.3, Cat5E (or Cat 6) UTP Ethernet cable (not Included) COMPLIANCE Compliance, IQ Combiner UL 1741. CAN/CSA C22.2 No.107.1, 47 CFR, Part 15, Class B, ICES 003 Production metering: ANSI C12.20 accuracy class 0.5(PV production) Consumption metering: accuracy class 2.5 Compliance, IQ Gateway UL 60601-1/CANCSA 22.2 No. 61010-1 To leam more about Enphase offerings, visit ennhase.com u E N P H A S E. 02021 Enphase Energy All rights reserved. Enphase, the Enphase logo, IQ Combiner 4/4C, and other names are trademarks of Enphase Energy, Ina Data subject to change.10-21-2021 CONTRACTOR Northwest Electric and Solar Address: 18001 73rd Ave NE i Kenmore WA 98028 Phone number: 206-356-0601 Appointments: nwsolar.com SolarNorthwest Electric ECB DATASHEET ENGINEEZINC Drawn by- New@engineerinc.io DATE. 0711312022 Project Name: 4900 Schneider Property Adress: 8508 218th St SW Edmonds, WA 98026 Project: Scale: PV SYSTEM AS INDICATED F-D 11.0