Loading...
BLD2022-0924_Manufacturer_Specifications_and_Installation_Instructions_7.13.2022_12.56.44_PM_2987247n ENPHASE IQ8 Series Microinverters Our newest I08 Microinverters are the industry's first microgrid-forming, software - defined microinverters with split -phase power conversion capability to convert DC power to AC power efficiently. The brain of the semiconductor -based microinverter is our proprietary application -specific integrated circuit (ASIC) which enables the microinverter to operate in grid -tied or off -grid modes. This chip is built in advanced 55nm technology with high speed digital logic and has super -fast response times to changing loads and grid events, alleviating constraints on battery sizing for home energy systems. I I Part of the Enphase Energy System, I08 Series Microinverters integrate with the Enphase 10 Battery, Enphase IQ Gateway. and the Enphase App monitoring and analysis software. wmc Connect PV modules quickly and easily to 108 Series Microinverters using the included Q-DCC-2 adapter cable with plug-n-play MC4 connectors. I08 Series Microinverters redefine reliability standards with more than one million cumulative hours of power -on testing. enabling an industry -leading limited warranty of up to 25 years. I08 Series Microinverters are UL Listed as PV Rapid Shut Down Equipment and conform with various regulations, when installed according to manufacturer's instructions. 0 2022 Enphase Energy. All rights reserved. Enphase. the Enphase logo. I08 microinverters. and other names are trademarks of Enphase Energy. Inc. Data subject to change. IQ8SE-DS-0001-01-EN-US-2022-03-01 Easy to install Lightweight and compact with plug-n-play connectors Power Line Communication (PLC) between components Faster installation with simple two -wire cabling High productivity and reliability Produce power even when the grid is down More than one million cumulative hours of testing Class II double -insulated enclosure Optimized for the latest high- powered PV modules Microgrid-forming Complies with the latest advanced grid support Remote automatic updates for the latest grid requirements Configurable to support a wide range of grid profiles Meets CA Rule 21(ILL 1741-SA) requirements 1,08 Series Microinverters Commonly used module pairings' w 235 - 350 235 - 440 260 - 460 295 - 500 320 - 540• 295 - 500+ Module compatibility 60-cell/120 half -cell 60-cell/120 half -cell. 66-cell/132 half -cell and 72-cell/144 half -cell MPPT voltage range V 27-37 29-45 33-45 36-45 38-45 38-45 Operating range V 25 - 48 25 - 58 Min/max start voltage V 30 / 48 30 / 58 Max input DC voltage V 50 60 Max DC current' [module Isc] A 15 Overvoltage class DC port II DC port backfeed current mA 0 PV array configuration 1xl Ungrounded array: No additional DC side protection required: AC side protection requires max 20A per branch circuit Peak output power VA 245 300 330 366 384 366 Max continuous output power VA 240 290 325 349 380 360 Nominal (L-L) voltage/range' V 240 / 211- 264 208 / 183 - 250 Max continuous output current A 1.0 1.21 1.35 1.45 1.58 1.73 Nominal frequency Hz 60 Extended frequency range Hz 50 - 68 Max units per 20 A (L-L) branch circuit° 16 13 11 11 10 9 Total harmonic distortion <5% Overvoltage class AC port III AC port backfeed current mA 30 Power factor setting 1.0 Grid -tied power factor (adjustable) 0.85leading - 0.85lagging Peak efficiency % 97.5 97.6 97.6 97.6 97.6 97.4 CEC weighted efficiency % 97 97 97 97.5 97 97 Night-time power consumption raw 60 MECHANICAL DATA Ambient temperature range -400C to+60°C (-40°F to+140°F) Relative humidity range 4%to 100%(condensing) DC Connector type MC4 Dimensions (HxWxD) 212 man (8.3") x 175 mm (6.9") x 30.2 man (1.2") Weight 1.08 kg (2.38lbs) Cooling Natural convection - no fans Approved for wet locations Yes Acoustic noise at 1 m <60 dBA Pollution degree PD3 Enclosure Class II double -insulated. corrosion resistant polymeric enclosure Environ. category / UV exposure rating NEMA Type 6 / outdoor CA Rule 21(UL 1741-SA). UL 62109-1. UL1741/IEEE1547. FCC Part 15 Class B. ICES-0003 Class B. CAN/CSA-C22.2 NO.107.1-01 Certifications This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014. NEC 2017. and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems. for AC and DC conductors. when installed according to manufacturer's instructions. (1) The IQBH-208 variant will be operating in grid -tied mode only at 208V AC. (2) No enforced DC/AC ratio. See the compatibility calculator at https://Iink.enphase.com/module-compatibility (3) Maximum continuous input DC current is 10.6A (4) Nominal voltage range can be extended beyond nominal if required by the utility. (5) Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. IQ8SE-DS-0001-01-EN-US-2022-03-01 CONTRACTOR Northwest Electric and Solar Address: 18001 73rd Ave NE i Kenmore WA 98028 Phone number: 206-356-0601 Appointments: nwsolar.com SolarNorthwest Electric INVERTER DATA SHEET CNGINCCZINC Drawn by: New@engineerinc.io DATE: 0711312022 Project Name: 4900 Schneider Property Adress: 8508 218th St SW Edmonds, WA 98026 Project: Scale: PV SYSTEM AS INDICATED D 6.0 Enphase• Energy // Rapid Shutdown Rapid shutdown is built-in The 2014 edition of the National Electrical Code (NEC 2014) added What's new in NEC 2014? new rapid shutdown requirements for PV systems installed on buildings. WEC =014. 0ectfon 600.12 app ' Enphase Microinverters fully meet rapid shutdown requirements in the to PV conductor; mw 10 fetid from new code without the need to install any additional electrical equipment. ft PV array and requaeG mx the conductor power down to 30 volt -- and 240 vok-an:psm within 10 uconds of rqD d shutdown initiaaort String inverters require work arounds for rapid shutdown Work around. pecialcsd Rapid ShuWao eiectncal box ins-iAed on tl roof w ahin 10 feet of array. Work around. c tutof. nv;"ch that is ea *?y accG- d3v to brct rcxponderr on the ground Worst around. Extra conduit in trY,(1azor Residential String Inverter Work around. ,7,rp ;nvSr,Qr lmtalied on roof, a hoctde envaonrnem mat =ng irwarterr amps not bull to liva in Commercial String Inverter Enphase comes standard with rapid shutdown capability All Enphwe microei- verters, won those thm were preV*urly inaaftd. inherontty nrtw. rapid shutdown requrwriontc-, no additional equiprnam or workzroundr needed Residential Microinverter To learn more, visit enphase.com Enphase rrocroinver&m can ;al* rhtR down a6aamatically, ki,,wng only to w mitage DC BieGticity iniamd! M the PV module Commercial Microinveortgr [e] enphase- ENPHASE. Install the Enphase IQ8 Series Microinverter To install Enphase IQ8 Series Microinverters, read and follow all warnings and instructions in this guide and in the Enphase I08 Series Microinverter Installation and Operation Manual at ennhase_com/support Safety warnings are listed on the back page of this guide. The Enphase Microinverter models listed in this guide do not require grounding electrode conductors (GEC), equipment grounding conductors (EGC), or grounded conductor (neutral). The microinverter has a Class II double -insulated rating, which includes ground fault protection (GFP). To support GFP, use only PV modules equipped with DC cables labeled PV Wire or PV Cable IMPORTANT: Enphase IQ8 Series Microinverters require the IQ Cable. An IQ Gateway is required to monitor performance of the IQ Microinverters. The Q Accessories work only with Enphase IQ8 Series Microinverters. Note: After you log in to your Enphase Installer Platform account from Enphase Installer app, Scan the microinverter QR code and connect to the Enphase IQ Gateway to track the system installation progress. PREPARATION A ) Download the Enphase Installer App and open it to log in to your Enphase Installer Platform account. With this Or ❑� app, scan the microinverter QR code and connect to the Enphase IQ Gateway to track system installation progress. To download, go to enichase com/toolkit or scan the QR code at right B) Refer to the following table and check PV module electrical compati- bility at: enphase com/en-us/sunnoLt/module-compalbAily- model DC connector Typical PV module* cell count IQ8-60-2-US MC-4 locking type Pair with 60 cell /120-half-cell modules MC-4 locking type Pair with 60 cell / 120-half-cell, 66 cell, or 72 cell / 144-half--cell 18%72-2-US IQSA-72-2-US IQSH-240-72-2-US IQ814-208-72-2-US MC-4 locking type Pair with 60 cell /120-half-cell, 66 cell, or72 cell / 144-half--cell * Enphase IQ8 Series Microinverters are compatible with bi-facial PV modules if the temperature adjusted electrical parameters (maximum power, voltage and current) ofthe modules, considering the front side electrical parameters (i.e., (A back side gain), are within the allowable rrdcroinverter input parameters range C) In addition to the Enphase Microinverters, PV modules and racking, you will need these Enphase IQ8 Series Microinverters: Enphase IQ Gateway (model ENV-IQ-AM1-240) communications gateway or Enphase IQ Combiner (check enphase.com for models): is required to monitor solar production. Tie wraps or cable clips (Q-CU P-100) Enphase Sealing Caps (Q-SEAL-10): for any unused connectors on the Enphase IQ Cable Enphase Terminator (Q-TERM-10): one needed at the end of each AC cable segment Enphase Disconnect Tool (Q-DISC-10) Enphase IQ Cable: Cable model Connector spacing* PV module orientation Connectors per box 0-12-10-240 1.3m Portrait (all) 240 Q-12-17-240 2.0m Landscape (60- and 66-cell) 240 Q-12-20-200 2.3m Landscape(72-cell) 200 *Allows for 30cm of cable slack D) Check that you have these other items: ACjunction box. Tools: screwdrivers, wire cutter, voltmeter, torque wrench, sockets, and wrenches for mounting hardware E) Protect your system with lightning and/or surge suppression devices. It is also important to have insurance that protects against lightning and electrical surges. F) Plan your AC branch circuits to meet the following limits for maximum number of microinverters per branch when protected with a 20amp over -current protection device (OCPD). Maximum* IQ8 Series Microinverters per AC branch circuit (sin- gle-phase) IQ8(240V) IQ8+ (240V) IQ8M (240V) 16 13 11 IQSA (240V) IQ8H (240V) IQ8H (208V) 11 10 9 * Limits may vary Refer to local requirements to define the number of microinverters per branch in your area. G ) Size the AC wire gauge to account for voltage rise. Select the correct wire size based on the distance from the beginning of the Enphase IQ Cable to the breaker in the load center. Design for a voltage rise total of less than 2°i for these sections. Refer to the Voltage Rise Technical Brief at enphase com/support for more information. Best practice: Center -feed the branch circuit to minimize voltage rise in a fully -populated branch. DC connector '*-,Tie wraps or cable clips -- Enphase IQ8 Series Microinverter (horizontal installation shown, vertical installation also allowed). ACjunction box Terminator 601lhase IQ�C.ble \AC connector 0 2021 Enphase Energy. All rights reserved. Enphase, the Enphase logo, Enphase IQ8 Series micranverters (IQ8, IQ8+, IQ8A, IQ8H and Q810), Enphase Installer Platform, Enphase IQ Gateway, and other trademarks or service names are the trademarks of Enphase Energy, Inc. Data subjectto change. Rev02-10-23-2021 III IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII III 140-00195-02 CONTRACTOR Northwest Electric and Solar Address: 18001 73rd Ave NE I Kenmore WA 98028 Phone number: 206-356-0601 Appointments: nwsolar.com Northwest Solar ENPHASE RAPID SHUTDOWN, COMPATIBILITY WITH PV E N G I NE Er"4 I NC Drawn by: New@engineerinc.io DATE: 0711312022 Project Name: 4900 Schneider Property Adress: 8508 218th St SW Edmonds, WA 98026 Project: Scale: PV SYSTEM AS INDICATED FD_ 7.0 SOL R I^ Solaria PowerXT° DC Panel SOL R I^ Solaria PowerXT11-400R-PM CONTRACTOR rrr Solaria PowerXT- 40OR-PM Cell Type Monocrystalline Silicon Max Power (Pmax) [W] 400 Dimensions (L x W x H) 64.72" x 47.4" x 1.57" Efficiency [%J 20.2 1644mm x 1204mm x 40mm Northwest Electric and Solar Open Circuit Voltage (Voc) IV] 51.1 Weight 21 kg / 46lbs Address: 18001 73rd Ave NE Short Circuit Current (Ise) [A] 9.82 Glass Type /Thickness AR Coated, Tempered / 2.84mm Kenmore WA 98028 Max Power Voltage(Vmp) [V] 42.4 Frame Type Black Anodized Aluminum Phone number: 206-356-0601 Solaria .rXT„ Max Power Current (Imp) [A] 9.41 Cable Type / Length 12 AWG PV Wire (UL) / 1000mm Appointments: nwsolar.com Power Tolerance [%] -0/+3 Connector Type MC4 Junction Box IP67 / 4 diodes Front Load 5400 Pa / 113 psf* Achieving over 20°k efficiency, Solaria PowerXT solar panels are one of the highest power panels in the residential and commercial solar Max Power (Pmax) [W) 295 Rear Load 2400 Pa / 50 psf* market. Compared to conventional panels, Solaria PowerXT panels have fewer gaps between the solar cells; this leads to higher power Open Circuit Voltage (Voc) IV] 48.1 'Refer to Solari a Installation Manual for detelIs and superior aesthetics. Solaria PowerXT Pure BlackTM panels are manufactured with black backsheet and frames, enhancing a home or Short Circuit Current (Ise) [A] 7.92 Certifications / Warranty building's architectural beauty. Max Power Voltage (Vmp) IV] 40.0 Northwest Max Power Current (Imp) [A] 7.59 Certifications UL 61730/UL1741/CEC CAN/CSA-C22.2 Solar TemperatureFire Type (UL 1703) 1 Higher Efficiency, Higher Power NOCT [°C] 45+/.2 Warranty 25 years* Solaria PowerXTpanels achieveover20% efficiency; conventional panels achieve 15%— Temp. Coeff. of Pmax 0 0 [%/ C] -0.39 'warranty details atwww.solaria.com 17°h efficiency. Solaria PowerXT panels are one of the highest power panels available. Temp. Coeff. of Voc [%/ °C] -0.29Temp. •' ' � ' Coeff. of Isc [%/ °CJ 0.04 Stacking Method Horizontal / Palletized Lower System Costs Design Parameters Panels/ Pallet 25 Solaria PowerXT panels produce more power per square meter area. This reduces Operating temperature [°CJ -40 to+85 Pallet Dims (L x W x H) 66.57" x 48.7" x 48.4" 1691 mm x 1238mm x 1230 mm installation costs due to fewer balance of system components. y P Max system Voltage [A] 1000 Pallet Weight 590 kg / 1300 Ibs Max Fuse Rating [p] PO Bypass Diodes [#] 4 Pallets / 40-ft Container 18 Improved Shading Tolerance Panels /40-ftContainer 450 Sub -strings are interconnected in parallel, within each of the four panel quadrants,IV 9 P P q Irradiance r r [r.da [s�n� ta�m� gin" which dramatically lowers the shading losses and boosts energy yield. umm 'gym A S ¢ r Improved Aesthetics 9 Compared to conventional panels, Solaria PowerXT panels have a more uniform appearance and superior aesthetics. Durability and Reliability urwaYr, e�" r .l MODULE Solder -less cell interconnections are highly reliable and designed to far exceed ' DATA SHEET the industry leading 25 year warranty. ° A 6 ! a S 10 IS 2a 1! >D 95 VOLTAGE(V) GO 13 p.on] ts.r� as.an] � dttmm �mm Comprehensive 25-Year Warrantmrmp.z>eMxromroio.lraM mas,mnlatenl About Solaria 1m% 98% 25-year Power, Parts and Labor from Solaria Typical Tier 1 industry warranty Drawn by: New@engineerinc.io DATE. 0711312022 Established in 2000, The Solaria Corporation has created one of the industry's most respected HOC PERFO%, IP portfolios, with over 250 issued and pending patents in PV solar cell and module technology. 2018 Headquartered in Oakland, California, Solaria has developed a technology platform that ® 9a1 to, L — sa% —81% [°s•nm] [. Project Name: 4900 Schneider Property Adresa: DNV•GL Tl1VRhelnlandm] unlocks the potential of solar energy. 8508 218th St SW Pid MODULE RELLABILRY SCORECARO Precisely Right. s io is Years zo zs FRAME PROFILE Edmonds, WA 98026 Project: I Scale: The Solana Corporation 1700 Broadway, Oakland, CA 94612 P: (510) 270-2507 www.solaria.com Copyright ® 2020 The Solaria Corporation The Solaria Corporation 1700 Broadway, Oakland, CA 94612 P (510) 270-2507 www.solarla com ® Copyrght 2020 The Solana Corporation PV SYSTEM AS INDICATED Product specifications are subjectto change without notice. SOL-DAT-0005 Rev 01 4-2020 Product specifications are subject to change without notice. SOL-DAT-0005 Rev 01 4-2020 F-D8.0 Ak IRONRIDGE Flush Mount System XR Rails e XR10 Rail XR100 Rail XR1000 Rail Bonded Splices CONTRACTOR Northwest Electric and Solar L Address: 18001 73rd Ave NE _ I Kenmore WA 98028 T A low -profile mounting rail The ultimate residential A heavyweight mounting All rails use internal splices Phone number: 206-356-0601 for regions with light snow. solar mounting rail. rail for commercial projects. for seamless connections. Appointments: nwsolar.com • 6'spanning capability 8' spanning capability 12' spanning capability Self -drilling screws • Moderate load capability Heavy load capability Extreme load capability Varying versions for rails • Clear and black finish Clear and black finish Clear anodized finish Forms secure bonding Clamps & Grounding UFOs Stopper Sleeves CAMO Grounding Lugs Northwest Electric Solar Universal Fastening Objects Snap onto the UFO to turn Bond modules to rails while Connect arrays to bond modules to rails. into a bonded end clamp. staying completely hidden. equipment ground. • Fully assembled & lubed Bonds modules to rails Universal end -cam clamp Low profile • Single, universal size Sized to match modules Tool -less installation Single tool installation • Clear and black finish Clear and black finish Fully assembled Mounts in any direction Built for solar's toughest roofs. Attachments ® — IronRidge builds the strongest mounting system for pitched roofs in solar. Every component has been tested to the limit and proven in extreme environments. FlashFoot2 Conduit Mount Slotted L-Feet Bonding Hardware Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and is also why our products are fully certified, code compliant and backed by a 25-year warranty. MW `! P=� • Strength Tested PE Certified _ � RACKING All components evaluated for superior Pre -stamped engineering letters Flash and mount XR Rails Flash and mount conduit, Drop -in design for rapid rail Bond and attach XR Rails DATA SHEET StrUCtUral performance. available In most states. with superior waterproofing. strut, or junction boxes. attachment. to roof attachments. • Twist -on Cap eases install Twist -on Cap eases install Secure rail connections T & Square Bolt options Class A Fire Rating Design Assistant • Wind -driven rain tested • Mill and black finish Wind -driven rain tested • Secures 3/4" or 1" conduit Slot for vertical adjusting • Clear and black finish Nut uses 7/16" socket • Assembled and lubricated ENGINEErZINC Certified to maintain the fire resistance !� Online software makes it simple to Resources Drawn by: New@engineerinc.io rating of the existing roof. create, share, and price projects. DATE: 0711312022 UL 2703 Listed System 25-Year Warranty _ Design Assistant Go from rough layout to fully engineered system. For free. ••R� NABCEP Certified Training Earn free continuing education credits, while learning more about our systems. Project Name: 4900 Schneider Propertyndress, Entire system and components meet Products guaranteed to be free %B�CEp 8508 218th St SW newest effective UL 2703 standard. of impairing defects. Go to IronRidge.conVdesign Go to Iron Ridge. con,/training Edmonds, WA 98026 Project: Scale: PV SYSTEM AS INDICATED G .• 90• ..: Othwe Pencing. Vemion 1.70 �/�►�FD 9.0 AOL IRON RIDGE The Strongest Attachment in Solar IronRidge FlashFoot2 raises the bar in solar roof protection. The unique water seal design is both elevated and encapsulated, delivering redundant layers of protection against water intrusion. In addition, the twist -on Cap perfectly aligns the rail attachment with the lag bolt to maximize mechanical strength. Twist -On Cap FlashFoot2's unique Cap design encapsi the lag bolt and locks into place with a sit twist. The Cap helps FlashFoot2 deliver superior structural strength, by aligning the rail and lag bolt in a concentric load path. Single Socket Size A custom -design lag bolt allows you to install FlashFoot2 with the same 7/16" socket size used on other Fkrsh Mount System components. Flash Foot2 Three -Tier Water Seal FlashFoot2's seal architecture utilizes three layers of protection. An elevated platform diverts water away, while a stack of rugged components raises the seal an entire inch. The seal is then fully-encapuslated by the Cap. FlashFoot2 is the first solar attachment to pass the TAS-100 Wind -Driven Rain Test. Water -Shedding Design An elevated platform diverts water away from the water seal. Installation Features B A Alignment Markers Quickly align the flashing with chalk lines to find pilot holes. C B Rounded Corners Makes it easier to handle and insert under the roof shingles. r . C Reinforcement Ribs A t Benefits of Concentric Loading Traditional solar attachments have a horizontal offset between the rail and lag bolt, which introduces leverage on the lag bolt and decreases uplift capacity. FlashFoot2 is the only product to align the rail and lag bolt. This concentric loading design results in a stronger attachment for the system. Testing & Certification Help to stiffen the flashing and prevent any bending or crinkling during installation. 1200 Y.FIsshFoa2 1000 800 u CL 600 M V4-1 400 � 200 0 FlashFoot •Leading Competitor 1 2 Rail -to -Lag Offset (in) Structural Certification Designed and Certified for Compliance with the International Building Code & ASCE/SEI-7. • Lo.-Cost Competitor Water Seal Ratings Water Sealing Tested to UL 441 Section 27 "Rain Test' and TAS 100-95 "Wind Driven Rain Test' by Intertek. Ratings applicable for composition shingle roofs having slopes between 2:12 and 12:12. UL 2703 Conforms to UL 2703 Mechanical and Bonding Requirements. See Flush Mount Install Manual for full ratings. 3 0 2016 IronRidge, Inc. AN rights reserved Ysit www.ironridge.com or call 14800-227-9523 for more information Version 1.0 r� CONTRACTOR Northwest Electric and Solar Address: 18001 73rd Ave NE Kenmore WA 98028 Phone number: 206-356-0601 Appointments: nwsolar.com Northwest Electric & Solar ATTACHMENT DATA SHEET ENGINEEZINC Drawn by: New@engineerinc.io DATE: 0711312022 Project Name: 4900 Schneider Property Adress: 8508 218th St SW Edmonds, WA 98026 Project: I Scale: PV SYSTEM L AS INDICATED F-D 10.0 Data Sheet Enphase Networking Enphase IQ Combiner 4/4C X-IQ-AM1-240-4 X-IQ-AM1-240-4C X-I( SX-IQ-AM1-240 LISTED To learn more about Enphase offerings, visit enohase.com The Enphase IQ Combiner 4/4C with Enphase IQ Gateway and integrated LTE-M1 cell modem (included only with IQ Combiner 4C) consolidates interconnection equipment into a single enclosure and streamlines IQ microinverters and storage installations by providing a consistent, pre -wired solution for residential applications. It offers up to four 2-pole input circuits and Eaton BR series busbar assembly. Smart • Includes IQ Gateway for communication and control • Includes Enphase Mobile Connect cellular modem (CELLMODEM-M1-06-SP-05), included only with IQ Combiner 4C • Includes solar shield to match Enphase IQ Battery aesthetics and deflect heat Flexible networking supports Wi-Fi, Ethernet, or cellular • Optional AC receptacle available for PLC bridge • Provides production metering and consumption monitoring Simple • Centered mounting brackets support single stud mounting • Supports bottom, back and side conduit entry Up to four 2-pole branch circuits for 240 VAC plug-in breakers (not included) • 80A total PV or storage branch circuits Reliable • Durable NRTL-certified NEMA type 3R enclosure Five-year limited warranty Two years labor reimbursement program coverage included for both the IQ Combiner SKU's UL listed ENPHASE Enphase IQ Combiner 4/4C MODEL NUMBER IQCombiner 4 (X-IQ-AM1.240-4) IQ Combiner 4 with Enphase IQ Gateway printed circuit board for integrated revenue grade PV production metering (ANSI C1220+/- 0.5%) and consumption monitoring (+/- 2.5%). Includes a silversolar shield to matchthe IQ Battery system and IQ System Controller 2 and to deflect heat. IQ Combiner 4C (X-IQ-AM1-240-4C) IQ Combiner 4C with Enphase IQ Gateway printed circuit board for integrated revenue grade PV production metering (ANSI C12.20 +/- 0.5%) and consumption monitoring (+/- 2.5`Yo). Includes Enphase Mobile Connect cellular modem (CELLMODEM-M1-06-SP-05), a plug -and -play Industrial -grade cell modem for systems upto 60 microinverters. (Available In the US, Canada, Mexico, Puerto Rico, and the LIS Virgin Islands,where there is adequate cellular service in the installation area.) Includes a silver solar shield to match the IQ Battery and 10 System Controller and to deflect heat. ACCESSORIES AND REPLACEMENT PARTS (not included, order separately) Ensemble Communications Kit Includes COMMS-KIT-01 and CELLMODEM-MI-06-SP-05 with 5-year Sprint data plan for COMMS-CELLMODEM-Ml-06 Ensemble sites CELLMODEM-Ml-06-SP-05 4G based LTE-M1 cellular modem with 5-year Sprint data plan CELLMODEM-Ml-06-AT-05 4G based LTE-M1 cellular modem with 5-year AT&T data plan Circuit Breakers Supports Eaton BR210, BR215, BR220, BR230, BR240, BR250, and OR260 circuit breakers. BRK-10A-2-240V Circuit breaker, 2 pole,10A, Eaton BR210 BRK-15A-2-240V Circuit breaker, 2 pole,l5A, Eaton BR215 BRK-20A-2P-240V Circuit breaker, 2 pole, 20A, Eaton BR220 BRK-15A-2P-240V-B Circuit breaker, 2 pole, l SA, Eaton BR215B with hold down kit support BRK-20A-2P-24OV-B Circuit breaker, 2 pole, 20A, Eaton BR2208with hold down kit support EPLC-01 Power line ca mer (communication bridge pair), quantity- one pair XA-SOLARSHIELD-ES Replacement solar shield for IQ Combiner 4/4C XA-PLUG-120-3 Accessory receptacle for Power Line Carrier in IQ Combiner 4/4C (required for EPLC-01) XA-ENV-PCBA-3 Replacement IQ Gateway printed circuit board (PCB) for Combiner 4/4C X-IQ-NA-HD-125A Hold down kit for Eaton circuit breaker with screws. ELECTRICAL SPECIFICATIONS Rating Continuous duty System voltage 1201240 VAC, 60 Hz Eaton BR series busbar rating 125A Max. continuous current rating 65 A Max. continuous current rating Oniputfrom PV/storage) 64A Max. fuse/circuit rating (output) 90 A Branch circuits (solar and/or storage) Up to four 2-pole Eaton BR series Distributed Generation (DG) breakers only (not included) Max. total branch circuit breaker rating (input) 80A of distributed generation / 95A with IQ Gateway breaker included Production metering CT 200 A solid core pre -installed and wired to IQ Gateway Consumption monitoring CT (CT-200-SPLIT) A pair of 200 A split core current transformers MECHANICAL DATA Dimensions (WxHxD) 37.5 x 49.5 x 16.8 cm (14.75• x 19.5" x 6.63"). Height is 21.06" (53.5 cm) with mounting brackets. Weight 7.5 kg (16.5 Ibs) Ambient temperature range -40° C to+46° C (40° to 115* F) Cooling Natural convection, plus heat shield Enclosure environmental rating Outdoor, NRTLcertified, NEMA type 3R, polycarbonate construction Wire sizes 20 A to 50 A breaker inputs: 14 to 4 AWG copper conductors 60 A breaker branch input: 4 to 1/0 AWG copper conductors Main lug combined output:10 to 2/OAWG copper conductors Neutral and ground: 14 to 1/0 copper conductors Always follow local code requirements for conductor sizing. Altitude To 2000 meters (6,560 feet) INTERNET CONNECTION OPTIONS integrated Wl-R 802.11b/g/n Cellular CELLMODEM-M1-06-SP-05, CELLMODEM-M7-06-AT-05 (4G based LTE-M1 cellular modem). Note that an Enphase Mobile Connect cellular modem is required for all Ensemble installations. Ethernet Optional, 802.3, Cat5E (or Cat 6) UTP Ethernet cable (not Included) COMPLIANCE Compliance, IQ Combiner UL 1741. CAN/CSA C22.2 No.107.1, 47 CFR, Part 15, Class B, ICES 003 Production metering: ANSI C12.20 accuracy class 0.5(PV production) Consumption metering: accuracy class 2.5 Compliance, IQ Gateway UL 60601-1/CANCSA 22.2 No. 61010-1 To leam more about Enphase offerings, visit ennhase.com u E N P H A S E. 02021 Enphase Energy All rights reserved. Enphase, the Enphase logo, IQ Combiner 4/4C, and other names are trademarks of Enphase Energy, Ina Data subject to change.10-21-2021 CONTRACTOR Northwest Electric and Solar Address: 18001 73rd Ave NE i Kenmore WA 98028 Phone number: 206-356-0601 Appointments: nwsolar.com SolarNorthwest Electric ECB DATASHEET ENGINEEZINC Drawn by- New@engineerinc.io DATE. 0711312022 Project Name: 4900 Schneider Property Adress: 8508 218th St SW Edmonds, WA 98026 Project: Scale: PV SYSTEM AS INDICATED F-D 11.0