BLD2022-0924_Manufacturer_Specifications_and_Installation_Instructions_7.13.2022_12.56.44_PM_2987247n ENPHASE
IQ8 Series Microinverters
Our newest I08 Microinverters are the industry's first microgrid-forming, software -
defined microinverters with split -phase power conversion capability to convert DC
power to AC power efficiently. The brain of the semiconductor -based microinverter
is our proprietary application -specific integrated circuit (ASIC) which enables the
microinverter to operate in grid -tied or off -grid modes. This chip is built in advanced
55nm technology with high speed digital logic and has super -fast response times
to changing loads and grid events, alleviating constraints on battery sizing for home
energy systems.
I I
Part of the Enphase Energy System, I08 Series
Microinverters integrate with the Enphase 10
Battery, Enphase IQ Gateway. and the Enphase
App monitoring and analysis software.
wmc
Connect PV modules quickly and easily to
108 Series Microinverters using the included
Q-DCC-2 adapter cable with plug-n-play MC4
connectors.
I08 Series Microinverters redefine reliability
standards with more than one million
cumulative hours of power -on testing.
enabling an industry -leading limited warranty
of up to 25 years.
I08 Series Microinverters are UL Listed as
PV Rapid Shut Down Equipment and conform
with various regulations, when installed
according to manufacturer's instructions.
0 2022 Enphase Energy. All rights reserved. Enphase. the Enphase logo. I08 microinverters.
and other names are trademarks of Enphase Energy. Inc. Data subject to change.
IQ8SE-DS-0001-01-EN-US-2022-03-01
Easy to install
Lightweight and compact with
plug-n-play connectors
Power Line Communication
(PLC) between components
Faster installation with simple
two -wire cabling
High productivity and reliability
Produce power even when the
grid is down
More than one million cumulative
hours of testing
Class II double -insulated
enclosure
Optimized for the latest high-
powered PV modules
Microgrid-forming
Complies with the latest
advanced grid support
Remote automatic updates for
the latest grid requirements
Configurable to support a wide
range of grid profiles
Meets CA Rule 21(ILL 1741-SA)
requirements
1,08 Series Microinverters
Commonly used module pairings'
w
235 - 350
235 - 440
260 - 460 295 - 500
320 - 540•
295 - 500+
Module compatibility
60-cell/120 half -cell
60-cell/120 half -cell. 66-cell/132 half
-cell and 72-cell/144 half -cell
MPPT voltage range
V
27-37
29-45
33-45 36-45
38-45
38-45
Operating range
V
25 - 48
25 - 58
Min/max start voltage
V
30 / 48
30 / 58
Max input DC voltage
V
50
60
Max DC current' [module Isc]
A
15
Overvoltage class DC port
II
DC port backfeed current
mA
0
PV array configuration
1xl Ungrounded array: No additional DC side protection required: AC side protection requires max 20A per branch circuit
Peak output power
VA
245
300
330 366
384
366
Max continuous output power
VA
240
290
325 349
380
360
Nominal (L-L) voltage/range'
V
240 / 211- 264
208 / 183 - 250
Max continuous output current
A
1.0
1.21
1.35 1.45
1.58
1.73
Nominal frequency
Hz
60
Extended frequency range
Hz
50 - 68
Max units per 20 A (L-L) branch circuit°
16
13
11 11
10
9
Total harmonic distortion
<5%
Overvoltage class AC port
III
AC port backfeed current
mA
30
Power factor setting
1.0
Grid -tied power factor (adjustable)
0.85leading - 0.85lagging
Peak efficiency
%
97.5
97.6
97.6 97.6
97.6
97.4
CEC weighted efficiency
%
97
97
97 97.5
97
97
Night-time power consumption
raw
60
MECHANICAL DATA
Ambient temperature range
-400C to+60°C (-40°F to+140°F)
Relative humidity range
4%to 100%(condensing)
DC Connector type
MC4
Dimensions (HxWxD)
212 man (8.3") x 175 mm (6.9") x 30.2 man (1.2")
Weight
1.08 kg (2.38lbs)
Cooling
Natural convection - no fans
Approved for wet locations
Yes
Acoustic noise at 1 m
<60 dBA
Pollution degree
PD3
Enclosure
Class II double -insulated. corrosion resistant polymeric enclosure
Environ. category / UV exposure rating
NEMA Type 6 / outdoor
CA Rule 21(UL 1741-SA). UL 62109-1. UL1741/IEEE1547. FCC Part 15 Class B. ICES-0003 Class B. CAN/CSA-C22.2 NO.107.1-01
Certifications This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014. NEC 2017. and NEC 2020 section
690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems. for AC and DC conductors. when installed according to
manufacturer's instructions.
(1) The IQBH-208 variant will be operating in grid -tied mode only at 208V AC. (2) No enforced DC/AC ratio. See
the compatibility calculator at https://Iink.enphase.com/module-compatibility (3) Maximum continuous input
DC current is 10.6A (4) Nominal voltage range can be extended beyond nominal if required by the utility. (5)
Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. IQ8SE-DS-0001-01-EN-US-2022-03-01
CONTRACTOR
Northwest Electric and Solar
Address: 18001 73rd Ave NE
i Kenmore WA 98028
Phone number: 206-356-0601
Appointments: nwsolar.com
SolarNorthwest Electric
INVERTER
DATA SHEET
CNGINCCZINC
Drawn by: New@engineerinc.io
DATE: 0711312022
Project Name:
4900 Schneider
Property Adress:
8508 218th St SW
Edmonds, WA 98026
Project:
Scale:
PV SYSTEM
AS INDICATED
D 6.0
Enphase• Energy // Rapid Shutdown
Rapid shutdown is built-in
The 2014 edition of the National Electrical Code (NEC 2014) added What's new in NEC 2014?
new rapid shutdown requirements for PV systems installed on buildings. WEC =014. 0ectfon 600.12 app '
Enphase Microinverters fully meet rapid shutdown requirements in the to PV conductor; mw 10 fetid from
new code without the need to install any additional electrical equipment. ft PV array and requaeG mx the
conductor power down to 30 volt --
and 240 vok-an:psm within 10
uconds of rqD d shutdown initiaaort
String inverters require work arounds for rapid shutdown
Work around.
pecialcsd Rapid ShuWao
eiectncal box ins-iAed on tl
roof w ahin 10 feet of array.
Work around.
c tutof. nv;"ch that is
ea *?y accG- d3v to brct
rcxponderr on the ground
Worst around.
Extra conduit in trY,(1azor
Residential String Inverter
Work around.
,7,rp ;nvSr,Qr lmtalied
on roof, a hoctde
envaonrnem mat =ng
irwarterr amps not bull
to liva in
Commercial String Inverter
Enphase comes standard with rapid shutdown capability
All Enphwe microei-
verters, won those thm
were preV*urly inaaftd.
inherontty nrtw. rapid
shutdown requrwriontc-,
no additional equiprnam
or workzroundr needed
Residential Microinverter
To learn more, visit enphase.com
Enphase rrocroinver&m
can ;al* rhtR down
a6aamatically, ki,,wng
only to w mitage DC
BieGticity iniamd! M
the PV module
Commercial Microinveortgr
[e] enphase-
ENPHASE.
Install the Enphase IQ8 Series Microinverter
To install Enphase IQ8 Series Microinverters, read and follow all warnings and instructions in this guide and in the Enphase I08 Series Microinverter
Installation and Operation Manual at ennhase_com/support Safety warnings are listed on the back page of this guide.
The Enphase Microinverter models listed in this guide do not require grounding electrode conductors (GEC), equipment grounding conductors (EGC), or
grounded conductor (neutral). The microinverter has a Class II double -insulated rating, which includes ground fault protection (GFP). To support GFP, use
only PV modules equipped with DC cables labeled PV Wire or PV Cable
IMPORTANT: Enphase IQ8 Series Microinverters require the IQ Cable. An IQ Gateway is required to monitor performance of the IQ Microinverters. The Q
Accessories work only with Enphase IQ8 Series Microinverters.
Note: After you log in to your Enphase Installer Platform account from Enphase Installer app, Scan the microinverter QR code and connect to the
Enphase IQ Gateway to track the system installation progress.
PREPARATION
A ) Download the Enphase Installer App and open it to log
in to your Enphase Installer Platform account. With this Or ❑�
app, scan the microinverter QR code and connect to
the Enphase IQ Gateway to track system installation
progress. To download, go to enichase com/toolkit or
scan the QR code at right
B) Refer to the following table and check PV module electrical compati-
bility at: enphase com/en-us/sunnoLt/module-compalbAily-
model
DC connector
Typical PV module* cell count
IQ8-60-2-US
MC-4 locking type
Pair with 60 cell /120-half-cell
modules
MC-4 locking type
Pair with 60 cell / 120-half-cell, 66
cell, or 72 cell / 144-half--cell
18%72-2-US
IQSA-72-2-US
IQSH-240-72-2-US
IQ814-208-72-2-US
MC-4 locking type
Pair with 60 cell /120-half-cell, 66
cell, or72 cell / 144-half--cell
* Enphase IQ8 Series Microinverters are compatible with bi-facial PV modules if
the temperature adjusted electrical parameters (maximum power, voltage and
current) ofthe modules, considering the front side electrical parameters (i.e., (A
back side gain), are within the allowable rrdcroinverter input parameters range
C) In addition to the Enphase Microinverters, PV modules and racking,
you will need these Enphase IQ8 Series Microinverters:
Enphase IQ Gateway (model ENV-IQ-AM1-240) communications
gateway or Enphase IQ Combiner (check enphase.com for models):
is required to monitor solar production.
Tie wraps or cable clips (Q-CU P-100)
Enphase Sealing Caps (Q-SEAL-10): for any unused connectors on
the Enphase IQ Cable
Enphase Terminator (Q-TERM-10): one needed at the end of each
AC cable segment
Enphase Disconnect Tool (Q-DISC-10)
Enphase IQ Cable:
Cable model
Connector
spacing*
PV module
orientation
Connectors
per box
0-12-10-240
1.3m
Portrait (all)
240
Q-12-17-240
2.0m
Landscape (60- and 66-cell)
240
Q-12-20-200
2.3m
Landscape(72-cell)
200
*Allows for 30cm of cable slack
D) Check that you have these other items:
ACjunction box.
Tools: screwdrivers, wire cutter, voltmeter, torque wrench, sockets,
and wrenches for mounting hardware
E) Protect your system with lightning and/or surge suppression devices. It
is also important to have insurance that protects against lightning and
electrical surges.
F) Plan your AC branch circuits to meet the following limits for maximum
number of microinverters per branch when protected with a 20amp
over -current protection device (OCPD).
Maximum* IQ8 Series Microinverters per AC branch circuit (sin-
gle-phase)
IQ8(240V)
IQ8+ (240V)
IQ8M (240V)
16
13
11
IQSA (240V)
IQ8H (240V)
IQ8H (208V)
11
10
9
* Limits may vary Refer to local requirements to define the number of
microinverters per branch in your area.
G ) Size the AC wire gauge to account for voltage rise. Select the correct
wire size based on the distance from the beginning of the Enphase IQ
Cable to the breaker in the load center. Design for a voltage rise total
of less than 2°i for these sections. Refer to the Voltage Rise Technical
Brief at enphase com/support for more information.
Best practice: Center -feed the branch circuit to minimize voltage rise in
a fully -populated branch.
DC connector
'*-,Tie wraps or cable clips
-- Enphase IQ8 Series Microinverter
(horizontal installation shown, vertical
installation also allowed).
ACjunction box
Terminator
601lhase IQ�C.ble
\AC connector
0 2021 Enphase Energy. All rights reserved.
Enphase, the Enphase logo, Enphase IQ8
Series micranverters (IQ8, IQ8+, IQ8A, IQ8H
and Q810), Enphase Installer Platform,
Enphase IQ Gateway, and other trademarks
or service names are the trademarks of
Enphase Energy, Inc. Data subjectto change.
Rev02-10-23-2021
III IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII III
140-00195-02
CONTRACTOR
Northwest Electric and Solar
Address: 18001 73rd Ave NE
I Kenmore WA 98028
Phone number: 206-356-0601
Appointments: nwsolar.com
Northwest
Solar
ENPHASE RAPID
SHUTDOWN,
COMPATIBILITY
WITH PV
E N G I NE Er"4 I NC
Drawn by: New@engineerinc.io
DATE: 0711312022
Project Name:
4900 Schneider
Property Adress:
8508 218th St SW
Edmonds, WA 98026
Project:
Scale:
PV SYSTEM
AS INDICATED
FD_
7.0
SOL R I^ Solaria PowerXT° DC Panel
SOL R I^
Solaria PowerXT11-400R-PM
CONTRACTOR
rrr
Solaria PowerXT-
40OR-PM
Cell Type Monocrystalline Silicon
Max Power (Pmax)
[W]
400
Dimensions (L x W x H) 64.72" x 47.4" x 1.57"
Efficiency
[%J
20.2
1644mm x 1204mm x 40mm
Northwest Electric and Solar
Open Circuit Voltage (Voc)
IV]
51.1
Weight 21 kg / 46lbs
Address: 18001 73rd Ave NE
Short Circuit Current (Ise)
[A]
9.82
Glass Type /Thickness AR Coated, Tempered / 2.84mm
Kenmore WA 98028
Max Power Voltage(Vmp)
[V]
42.4
Frame Type Black Anodized Aluminum
Phone number: 206-356-0601
Solaria .rXT„
Max Power Current (Imp)
[A]
9.41
Cable Type / Length 12 AWG PV Wire (UL) / 1000mm
Appointments: nwsolar.com
Power Tolerance
[%]
-0/+3
Connector Type MC4
Junction Box IP67 / 4 diodes
Front Load 5400 Pa / 113 psf*
Achieving over 20°k efficiency, Solaria PowerXT solar panels are one of the highest power panels in the residential and commercial solar
Max Power (Pmax)
[W)
295
Rear Load 2400 Pa / 50 psf*
market. Compared to conventional panels, Solaria PowerXT panels have fewer gaps between the solar cells; this leads to higher power
Open Circuit Voltage (Voc)
IV]
48.1
'Refer to Solari a Installation Manual for detelIs
and superior aesthetics. Solaria PowerXT Pure BlackTM panels are manufactured with black backsheet and frames, enhancing a home or
Short Circuit Current (Ise)
[A]
7.92
Certifications / Warranty
building's architectural beauty.
Max Power Voltage (Vmp)
IV]
40.0
Northwest
Max Power Current (Imp)
[A]
7.59
Certifications UL 61730/UL1741/CEC
CAN/CSA-C22.2
Solar
TemperatureFire
Type (UL 1703) 1
Higher Efficiency, Higher Power
NOCT
[°C]
45+/.2
Warranty 25 years*
Solaria PowerXTpanels achieveover20% efficiency; conventional panels achieve 15%—
Temp. Coeff. of Pmax
0 0
[%/ C]
-0.39
'warranty details atwww.solaria.com
17°h efficiency. Solaria PowerXT panels are one of the highest power panels available.
Temp. Coeff. of Voc
[%/ °C]
-0.29Temp.
•' ' � '
Coeff. of Isc
[%/ °CJ
0.04
Stacking Method Horizontal / Palletized
Lower System Costs
Design Parameters
Panels/ Pallet 25
Solaria PowerXT panels produce more power per square meter area. This reduces
Operating temperature
[°CJ
-40 to+85
Pallet Dims (L x W x H) 66.57" x 48.7" x 48.4"
1691 mm x 1238mm x 1230 mm
installation costs due to fewer balance of system components.
y P
Max system Voltage
[A]
1000
Pallet Weight 590 kg / 1300 Ibs
Max Fuse Rating
[p]
PO
Bypass Diodes
[#]
4
Pallets / 40-ft Container 18
Improved Shading Tolerance
Panels /40-ftContainer 450
Sub -strings are interconnected in parallel, within each of the four panel quadrants,IV
9 P P q
Irradiance r r
[r.da [s�n� ta�m�
gin"
which dramatically lowers the shading losses and boosts energy yield.
umm 'gym
A S ¢ r
Improved Aesthetics
9
Compared to conventional panels, Solaria PowerXT panels have a more uniform
appearance and superior aesthetics.
Durability and Reliability
urwaYr, e�" r .l
MODULE
Solder -less cell interconnections are highly reliable and designed to far exceed
'
DATA SHEET
the industry leading 25 year warranty.
°
A 6 !
a S 10 IS
2a 1! >D 95
VOLTAGE(V)
GO 13
p.on] ts.r� as.an]
� dttmm
�mm
Comprehensive 25-Year Warrantmrmp.z>eMxromroio.lraM
mas,mnlatenl
About Solaria
1m%
98%
25-year Power, Parts and Labor from Solaria
Typical Tier 1 industry warranty
Drawn by: New@engineerinc.io
DATE. 0711312022
Established in 2000, The Solaria Corporation has created one of the industry's most respected HOC PERFO%,
IP portfolios, with over 250 issued and pending patents in PV solar cell and module technology. 2018
Headquartered in Oakland, California, Solaria has developed a technology platform that ®
9a1
to,
L
— sa%
—81%
[°s•nm]
[.
Project Name:
4900 Schneider
Property Adresa:
DNV•GL
Tl1VRhelnlandm]
unlocks the potential of solar energy.
8508 218th St SW
Pid MODULE
RELLABILRY SCORECARO Precisely Right.
s
io is Years
zo zs
FRAME PROFILE
Edmonds, WA 98026
Project: I Scale:
The Solana Corporation 1700 Broadway, Oakland, CA 94612 P: (510) 270-2507 www.solaria.com Copyright ® 2020 The Solaria Corporation
The Solaria Corporation 1700 Broadway, Oakland, CA 94612
P (510) 270-2507 www.solarla
com ® Copyrght 2020 The Solana Corporation
PV SYSTEM AS INDICATED
Product specifications are subjectto change without notice. SOL-DAT-0005 Rev 01 4-2020
Product specifications are subject
to change without notice.
SOL-DAT-0005 Rev 01 4-2020
F-D8.0
Ak
IRONRIDGE
Flush Mount System
XR Rails e
XR10 Rail
XR100 Rail
XR1000 Rail
Bonded Splices
CONTRACTOR
Northwest Electric and Solar
L
Address: 18001 73rd Ave NE
_
I Kenmore WA 98028
T
A low -profile mounting rail
The ultimate residential
A heavyweight mounting
All rails use internal splices
Phone number: 206-356-0601
for regions with light snow.
solar mounting rail.
rail for commercial projects.
for seamless connections.
Appointments: nwsolar.com
• 6'spanning capability
8' spanning capability
12' spanning capability
Self -drilling screws
• Moderate load capability
Heavy load capability
Extreme load capability
Varying versions for rails
• Clear and black finish
Clear and black finish
Clear anodized finish
Forms secure bonding
Clamps & Grounding
UFOs
Stopper Sleeves
CAMO
Grounding Lugs
Northwest Electric
Solar
Universal Fastening Objects
Snap onto the UFO to turn
Bond modules to rails while
Connect arrays to
bond modules to rails.
into a bonded end clamp.
staying completely hidden.
equipment ground.
• Fully assembled & lubed
Bonds modules to rails
Universal end -cam clamp
Low profile
• Single, universal size
Sized to match modules
Tool -less installation
Single tool installation
• Clear and black finish
Clear and black finish
Fully assembled
Mounts in any direction
Built for
solar's toughest roofs.
Attachments ® —
IronRidge
builds the strongest mounting system for pitched
roofs in solar.
Every component has been tested to
the limit and proven in extreme environments.
FlashFoot2
Conduit Mount
Slotted L-Feet
Bonding Hardware
Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and
is also why our products are fully certified, code compliant and backed by a 25-year warranty.
MW
`! P=�
•
Strength Tested
PE Certified
_ �
RACKING
All components evaluated for superior
Pre -stamped engineering letters
Flash and mount XR Rails
Flash and mount conduit,
Drop -in design for rapid rail
Bond and attach XR Rails
DATA SHEET
StrUCtUral performance.
available In most states.
with superior waterproofing.
strut, or junction boxes.
attachment.
to roof attachments.
• Twist -on Cap eases install
Twist -on Cap eases install
Secure rail connections
T & Square Bolt options
Class A Fire Rating
Design Assistant
• Wind -driven rain tested
• Mill and black finish
Wind -driven rain tested
• Secures 3/4" or 1" conduit
Slot for vertical adjusting
• Clear and black finish
Nut uses 7/16" socket
• Assembled and lubricated
ENGINEErZINC
Certified to maintain the fire resistance
!�
Online software makes it simple to
Resources
Drawn by: New@engineerinc.io
rating of the existing roof.
create, share, and price projects.
DATE: 0711312022
UL 2703 Listed System
25-Year Warranty
_ Design Assistant
Go from rough layout to fully
engineered system. For free.
••R� NABCEP Certified Training
Earn free continuing education credits,
while learning more about our systems.
Project Name:
4900 Schneider
Propertyndress,
Entire system and components meet
Products guaranteed to be free
%B�CEp
8508 218th St SW
newest effective UL 2703 standard.
of impairing defects.
Go to
IronRidge.conVdesign
Go to Iron Ridge.
con,/training
Edmonds, WA 98026
Project: Scale:
PV SYSTEM AS INDICATED
G .•
90•
..: Othwe Pencing. Vemion 1.70
�/�►�FD
9.0
AOL IRON RIDGE
The Strongest Attachment in Solar
IronRidge FlashFoot2 raises the bar in solar roof
protection. The unique water seal design is both
elevated and encapsulated, delivering redundant layers
of protection against water intrusion. In addition, the
twist -on Cap perfectly aligns the rail attachment with the
lag bolt to maximize mechanical strength.
Twist -On Cap
FlashFoot2's unique Cap design encapsi
the lag bolt and locks into place with a sit
twist. The Cap helps FlashFoot2 deliver
superior structural strength, by aligning
the rail and lag bolt in a concentric
load path.
Single Socket Size
A custom -design lag bolt allows
you to install FlashFoot2 with
the same 7/16" socket size
used on other Fkrsh Mount
System components.
Flash Foot2
Three -Tier Water Seal
FlashFoot2's seal architecture utilizes three
layers of protection. An elevated platform
diverts water away, while a stack of rugged
components raises the seal an entire inch.
The seal is then fully-encapuslated by the
Cap. FlashFoot2 is the first solar attachment
to pass the TAS-100 Wind -Driven Rain Test.
Water -Shedding Design
An elevated platform diverts water
away from the water seal.
Installation Features
B
A Alignment Markers
Quickly align the flashing with chalk lines to find pilot holes.
C
B Rounded Corners
Makes it easier to handle and insert under the roof shingles.
r . C Reinforcement Ribs
A t
Benefits of Concentric Loading
Traditional solar attachments have a
horizontal offset between the rail and lag
bolt, which introduces leverage on the lag
bolt and decreases uplift capacity.
FlashFoot2 is the only product to align the
rail and lag bolt. This concentric loading
design results in a stronger attachment for
the system.
Testing & Certification
Help to stiffen the flashing and prevent any bending or
crinkling during installation.
1200
Y.FIsshFoa2
1000
800
u
CL 600
M
V4-1 400
� 200
0
FlashFoot
•Leading Competitor
1 2
Rail -to -Lag Offset (in)
Structural Certification
Designed and Certified for Compliance with the International Building Code & ASCE/SEI-7.
• Lo.-Cost Competitor
Water Seal Ratings
Water Sealing Tested to UL 441 Section 27 "Rain Test' and TAS 100-95 "Wind Driven Rain Test' by Intertek.
Ratings applicable for composition shingle roofs having slopes between 2:12 and 12:12.
UL 2703
Conforms to UL 2703 Mechanical and Bonding Requirements. See Flush Mount Install Manual for full ratings.
3
0 2016 IronRidge, Inc. AN rights reserved Ysit www.ironridge.com or call 14800-227-9523 for more information Version 1.0 r�
CONTRACTOR
Northwest Electric and Solar
Address: 18001 73rd Ave NE
Kenmore WA 98028
Phone number: 206-356-0601
Appointments: nwsolar.com
Northwest Electric
& Solar
ATTACHMENT
DATA SHEET
ENGINEEZINC
Drawn by: New@engineerinc.io
DATE: 0711312022
Project Name:
4900 Schneider
Property Adress:
8508 218th St SW
Edmonds, WA 98026
Project:
I Scale:
PV SYSTEM
L AS INDICATED
F-D
10.0
Data Sheet
Enphase Networking
Enphase
IQ Combiner 4/4C
X-IQ-AM1-240-4
X-IQ-AM1-240-4C
X-I(
SX-IQ-AM1-240
LISTED
To learn more about Enphase offerings, visit enohase.com
The Enphase IQ Combiner 4/4C with Enphase
IQ Gateway and integrated LTE-M1 cell
modem (included only with IQ Combiner 4C)
consolidates interconnection equipment
into a single enclosure and streamlines IQ
microinverters and storage installations by
providing a consistent, pre -wired solution for
residential applications. It offers up to four
2-pole input circuits and Eaton BR series
busbar assembly.
Smart
• Includes IQ Gateway for communication and control
• Includes Enphase Mobile Connect cellular modem
(CELLMODEM-M1-06-SP-05), included only with IQ
Combiner 4C
• Includes solar shield to match Enphase IQ Battery
aesthetics and deflect heat
Flexible networking supports Wi-Fi,
Ethernet, or cellular
• Optional AC receptacle available for PLC bridge
• Provides production metering and consumption
monitoring
Simple
• Centered mounting brackets support single
stud mounting
• Supports bottom, back and side conduit entry
Up to four 2-pole branch circuits for 240 VAC
plug-in breakers (not included)
• 80A total PV or storage branch circuits
Reliable
• Durable NRTL-certified NEMA type 3R enclosure
Five-year limited warranty
Two years labor reimbursement program coverage
included for both the IQ Combiner SKU's
UL listed
ENPHASE
Enphase IQ Combiner 4/4C
MODEL NUMBER
IQCombiner 4 (X-IQ-AM1.240-4)
IQ Combiner 4 with Enphase IQ Gateway printed circuit board for integrated revenue grade PV production metering (ANSI
C1220+/- 0.5%) and consumption monitoring (+/- 2.5%). Includes a silversolar shield to matchthe IQ Battery system and
IQ System Controller 2 and to deflect heat.
IQ Combiner 4C (X-IQ-AM1-240-4C)
IQ Combiner 4C with Enphase IQ Gateway printed circuit board for integrated revenue grade PV production metering
(ANSI C12.20 +/- 0.5%) and consumption monitoring (+/- 2.5`Yo). Includes Enphase Mobile Connect cellular modem
(CELLMODEM-M1-06-SP-05), a plug -and -play Industrial -grade cell modem for systems upto 60 microinverters.
(Available In the US, Canada, Mexico, Puerto Rico, and the LIS Virgin Islands,where there is adequate cellular service in
the installation area.) Includes a silver solar shield to match the IQ Battery and 10 System Controller and to deflect heat.
ACCESSORIES AND REPLACEMENT PARTS
(not included, order separately)
Ensemble Communications Kit
Includes COMMS-KIT-01 and CELLMODEM-MI-06-SP-05 with 5-year Sprint data plan for
COMMS-CELLMODEM-Ml-06
Ensemble sites
CELLMODEM-Ml-06-SP-05
4G based LTE-M1 cellular modem with 5-year Sprint data plan
CELLMODEM-Ml-06-AT-05
4G based LTE-M1 cellular modem with 5-year AT&T data plan
Circuit Breakers
Supports Eaton BR210, BR215, BR220, BR230, BR240, BR250, and OR260 circuit breakers.
BRK-10A-2-240V
Circuit breaker, 2 pole,10A, Eaton BR210
BRK-15A-2-240V
Circuit breaker, 2 pole,l5A, Eaton BR215
BRK-20A-2P-240V
Circuit breaker, 2 pole, 20A, Eaton BR220
BRK-15A-2P-240V-B
Circuit breaker, 2 pole, l SA, Eaton BR215B with hold down kit support
BRK-20A-2P-24OV-B
Circuit breaker, 2 pole, 20A, Eaton BR2208with hold down kit support
EPLC-01
Power line ca mer (communication bridge pair), quantity- one pair
XA-SOLARSHIELD-ES
Replacement solar shield for IQ Combiner 4/4C
XA-PLUG-120-3
Accessory receptacle for Power Line Carrier in IQ Combiner 4/4C (required for EPLC-01)
XA-ENV-PCBA-3
Replacement IQ Gateway printed circuit board (PCB) for Combiner 4/4C
X-IQ-NA-HD-125A
Hold down kit for Eaton circuit breaker with screws.
ELECTRICAL SPECIFICATIONS
Rating
Continuous duty
System voltage
1201240 VAC, 60 Hz
Eaton BR series busbar rating
125A
Max. continuous current rating
65 A
Max. continuous current rating Oniputfrom PV/storage)
64A
Max. fuse/circuit rating (output)
90 A
Branch circuits (solar and/or storage)
Up to four 2-pole Eaton BR series Distributed Generation (DG) breakers only (not included)
Max. total branch circuit breaker rating (input)
80A of distributed generation / 95A with IQ Gateway breaker included
Production metering CT
200 A solid core pre -installed and wired to IQ Gateway
Consumption monitoring CT (CT-200-SPLIT)
A pair of 200 A split core current transformers
MECHANICAL DATA
Dimensions (WxHxD)
37.5 x 49.5 x 16.8 cm (14.75• x 19.5" x 6.63"). Height is 21.06" (53.5 cm) with mounting brackets.
Weight
7.5 kg (16.5 Ibs)
Ambient temperature range
-40° C to+46° C (40° to 115* F)
Cooling
Natural convection, plus heat shield
Enclosure environmental rating
Outdoor, NRTLcertified, NEMA type 3R, polycarbonate construction
Wire sizes
20 A to 50 A breaker inputs: 14 to 4 AWG copper conductors
60 A breaker branch input: 4 to 1/0 AWG copper conductors
Main lug combined output:10 to 2/OAWG copper conductors
Neutral and ground: 14 to 1/0 copper conductors
Always follow local code requirements for conductor sizing.
Altitude
To 2000 meters (6,560 feet)
INTERNET CONNECTION OPTIONS
integrated Wl-R
802.11b/g/n
Cellular
CELLMODEM-M1-06-SP-05, CELLMODEM-M7-06-AT-05 (4G based LTE-M1 cellular modem). Note that an Enphase
Mobile Connect cellular modem is required for all Ensemble installations.
Ethernet
Optional, 802.3, Cat5E (or Cat 6) UTP Ethernet cable (not Included)
COMPLIANCE
Compliance, IQ Combiner
UL 1741. CAN/CSA C22.2 No.107.1, 47 CFR, Part 15, Class B, ICES 003
Production metering: ANSI C12.20 accuracy class 0.5(PV production)
Consumption metering: accuracy class 2.5
Compliance, IQ Gateway
UL 60601-1/CANCSA 22.2 No. 61010-1
To leam more about Enphase offerings, visit ennhase.com u E N P H A S E.
02021 Enphase Energy All rights reserved. Enphase, the Enphase logo, IQ Combiner 4/4C, and other names are trademarks of
Enphase Energy, Ina Data subject to change.10-21-2021
CONTRACTOR
Northwest Electric and Solar
Address: 18001 73rd Ave NE
i Kenmore WA 98028
Phone number: 206-356-0601
Appointments: nwsolar.com
SolarNorthwest Electric
ECB
DATASHEET
ENGINEEZINC
Drawn by- New@engineerinc.io
DATE. 0711312022
Project Name:
4900 Schneider
Property Adress:
8508 218th St SW
Edmonds, WA 98026
Project:
Scale:
PV SYSTEM
AS INDICATED
F-D
11.0