Loading...
BLD2022-0927_Site_Plan_7.13.2022_3.58.14_PM_298817422 SunPower-A410w E-ACPV mods on East - facing standing seam metal roof @ 3° pitch (1:12). Seams @ -17" o.c. Mounting: S-5-S or ACE-A2 seam clamps + L-feet Racking: SMR rails Distributed Load (PSF): 2.5 Ibs/sq.ft. Wind Zone: 1 (90 mph) Exposure Category: B Access: Medium gorilla ladder @ front Conduit Runs: -50' of OF wire already ran for 2 strings/circuits from 1-1/2" conduit on rooftop down to west exterior wall by SnoPUD utility meter (see page 2 for all details) 4 solar components & SnoPUD meter (on wall under deck) PEAK Standing Seam attachment details - S-5-S or ACE A2 clamps @ 48" typ. spacing Solar rail_ 3/8" SS bolt & nut Standing metal L-foot roof seam / Seam clamp 22 SPR-A410w-WHT E-ACPV w/ 366w microinverters — 2 strings of 11 mods Utility/District: PROPERTY OF Sunergy Systems pAr y� SnoPUD WSUNFRO 1 S STEMS MICity of O'Connor -King Leary Way 4546 Seatte, WA 98107NW Edmonds Project DrW a�: 9.02 kW SunPower E-ACPV Photovoltaic system Michael Po orzelski Site Address: Description: Appmvedbv: 729 Laurel St. Jon Lan e, NABCEP PV ROOF PLAN Date:7/212/2022 Edmonds, WA 98020 DRAWING 72.2 (1835) 0 SunPower A -series EM modules: 40" w x 72.2" t 70 v 12"-10" 2"-16" 3' 0 3' Existing 1-'/2" conduit ran to rooftop 0 3° pitch 14'-17' ladder FRONT O F HOUSE/ (medium gorilla ladder) DRIVEWAY