BLD2022-0103+Energy_Calculations+1.21.2022_3.15.38_PM+2635015WASHINGTON STATE ENERGY CODE REQUIREMENTS PRESCRIPTIVE REQUIREMENTS FOR GROUP R OCCUPANCY - MARINE 4 FENESTRATION SKYLWT" GLAZED FENESTRATION CEILING WOOD FRAME MASS WALL FLOOR LOW-GRADE` 1 SLA50 U-FACTOle U-FACTOR R-VALUES R-VALUE R-vALUE' R-VALUE WALL R-VALUE DEPUE 4 TH 030 050 NR 49 21 INT 21 / 21h 300 10/15/21 INT + TB 10, 2 FT FOR SI: 1 FOOT an 3048 MM, Cl = CONTINUOUS INSULATION, INT = INTERMEDIATE FRAMING. THE PROJECT IS A SINGLE FAMILY RESIDENCE OR DUPLEX. THE PROJECT IS WOOD FRAME, OR ALL OF THE INSULATION IS INTERIOR OR EXTERIOR OF THE FRAMING. ALL BUILDING COMPONENTS MEET THE REQUIREMENTS LISTED IN THE TABLE ABOVE. THE PROJECT WILL MEET ALL OTHER PROVISIONS OF THE WSEC AND VIAQ. a R-VALUES ARE MINIMUMS. U-FACTORS AND SHGC ARE MAXIMUMS. WHEN INSULATION IS INSTALLED IN A CAVITY WHICH IS LESS THAN THE LABEL OR DESIGN THICKNESS OF THE INSULATION, THE COMPRESSED R-VALUE OF THE INSULATION FROM APPENDIX TABLE AIOIA SHALL NOT BE LESS THAN THE R-VALUE SPECIFIED IN THE TABLE. b THE FENESTRATION U-FACTOR COLUMN EXCLUDES SKYLIGHTS. THE SHGC COLUMN APPLIES TO ALL GLAZED FENESTRATION. EXCEPTION: SKYLIGHTS MAY BE EXCLUDED FROM GLAZED FENESTRATION SHGC REQUIREMENTS IN CLIMATE ZONES I THROUGH 3 WHERE THE SHGC FOR SUCH SKYLIGHTS DOES NOT EXCEED 0.30. "'10/15/21+TB" MEANS R-10 CONTINUOUS INSULATION ON THE EXTERIOR OF THE WALL, OR R-15 CAVITY INSULATION PLU& A THERMAL BREAK BETWEEN THE SLAB AND THE BASEMENT WALL AT THE INTERIOR OF THE BASEMENT WALL. 90/15/2145" SHALL BE PERMITTED TO BE MET WITH R-13 CAVITY INSULATION ON THE INTERIOR OF THE BASEMENT WALL PLUS R-5 CONTINUOUS INSULATION ON THE INTERIOR OR EXTERIOR OF THE WALL. "10/13" MEANS R-10 CONTINUOUS INSULATION ON THE INTERIOR OR EXTERIOR OF THE HOME OR R-13 CAVITY INSULATION AT THE INTERIOR OF THE BASEMENT WALL. "TB" MEANS THERMAL BREAK BETWEEN FLOOR SLAB AND BASEMENT WALL. d R-10 CONTINUOUS INSULATION IS REQUIRED UNDER HEATED SLAB ON GRADE FLOORS. SEE R40229.1. ° N/A 'BASEMENT WALL INSULATION IS NOT REQUIRED IN WARM-HUMI LOCATIONS AS DEFINED BY FIGURE R30IJ AND TABLE R301.1. 9 N/A h FIRST VALUE IS CAVITY INSULATION, SECOND IS CONTINUOUS INSULATION OR INSULATED SIDING, SO s+v MEANS R-13 CAVITY INSULATION PLUS R-5 CONTINUOUS INSULATION OR INSULATED SIDING. IF STRUCTURAL SHEATHING COVERS 40 PERCENT OR LESS OF THE EXTERIOR, CONTINUOUS INSULATION R-VALUE SHALL BE PERMITTED TO BE REDUCED BY NO MORE THAN R-3 IN THE LOCATIONS WHERE STRUCTURAL SHEATHING IS USED TO MAINTAIN A CONSISTENT TOTAL SHEATHING THICKNESS. 'THE SECOND R-VALUE APPLIES WHEN MORE THAN HALF THE INSULATION IS ON THE INTERIOR OF THE MASS WALL. d FOR SINGLE RAFTER- OR JOIST -VAULTED CEILINGS, THE INSULATION MAY BE REDUCED TO R-3& k INT. (INTERMEDIATE FRAMING) DENOTES STANDARD FRAMING 16 INCHES SIN CENTER WITH HEADERS INSULATED WITH MINIMUM OF R-10 INSULATION. LOG AND SOLID TIMBER WALLS WITH A MINIMUM AVERAGE THICKNESS OF 3B INCHES ARE EXEMPT FROM THIS INSULATION REQUIREMENT.