Loading...
APPROVED BLD2022-0646+Site_Plan+5.17.2022_1.02.53_PM+2875570ABBREVIATIONS O DIAMETER MCA MINIMUM CIRCUIT AMPACITY MECH MECHANICAL AFF ABOVE FINISHED FLOOR MIN MINIMUM AHU AIR HANDLING UNIT MOCP MAXIMUM OVERCURRENT PROTECTION BHP BRAKE HORSEPOWER NC NOISE CRITERIA BDD BACKDRAFT DAMPER NOM NOMINAL BPD BY-PASS DAMPER NO. NUMBER BTU/ H BRITISH THERMAL UNIT PER HOUR NTS NOT TO SCALE C CONDENSATE DRAIN PIPING CD CEILING DIFFUSER OA OUTSIDE AIR CFM CUBIC FEET PER MINUTE OBD OPPOSED BLADE DAMPER ODD OUTSIDE DIMENSION OF DIAMETER DB DECIBAL OU OUTDOOR UNIT DH DUCT HEATER DOAS DEDICATED OUTDOOR AIR SYSTEM POC POINT OF CONNECTION PSI POUNDS PER SQUARE INCH EER ENERGY EFFICIENCY RATIO EG EXHAUST GRILLE R REFRIGERATION LINES ESP EXTERNAL STATIC PRESSURE RA RETURN AIR EXH EXHAUST RCP REFLECTED CEILING PLAN RG RETURN GRILLE FCU FAN COIL UNIT RPM REVOLUTIONS PER MINUTE FD FIRE DAMPER RTU ROOFTOP UNIT FPM FEET PER MINUTE FSD FIRE AND SMOKE DAMPER SD SUPPLY DIFFUSER SL SOUND LINED GF GAS FURNACE SP STATIC PRESSURE GRID GRILLE, REGISTER, DIFFUSER SM/ D SMOKE DAMPER HP HORSEPOWER, HEAT PUMP TG TRANSFER GRILLE HRU HEAT RECOVERY UNIT T'STAT THERMOSTAT HVAC HEATING VENTILATION & AIR CONDITIONING TYP TYPICAL ID INSIDE DIMENSION VAV VARIABLE AIR VOLUME IECC INTERNATIONAL ENERGY CONSERVATION CODE VFD VARIABLE FREQUENCY DRIVE IFR INFRARED HEATER VTR VENT TO ROOF IMC INTERNATIONAL MECHANICAL CODE IN INCH WSEC WASHINGTON STATE ENERGY CODE ISP INTERNAL STATIC PRESSURE ZD ZONE DAMPER LB POUND LVR LOUVER PLAN SYMBOLS Z CEILING SUPPLY DIFFUSER Z CEILING RETURN GRILLE Z CEILING EXHAUST GRILLE nv v FLEX DUCT ,Aj CEILING EXHAUST FAN INLINE EXHAUST FAN Q EXHAUST FAN UP ROUND DUCT UP ROUND DUCT DOWN VAV FAN BOX BALANCE DAMPER (MANUAL) RFD FIRE DAMPER __� FSD FIRE SMOKE DAMPER M­4 MOTORIZED DAMPER B ZONE DAMPER FIRE DAMPER ABOVE DIFFUSER FIRE DAMPER ABOVE GRILLE THERMOSTAT SENSOR 0 GAS METER sM SMOKE DETECTOR SD-# SUPPLY DIFFUSER RG-# RETURN GRILLE EF-# EXHAUST FAN TG-# TRANSFER GRILLE - C - CONDENSATE LINE - R - PAIRED REFER LINES GENERAL HVAC NOTES 1. COMPLETE INSTALLATION OF MECHANICAL SYSTEMS SHALL MEET APPLICABLE CODES PER 2018 IBC WITH WASHINGTON STATE AMENDMENTS, 2018 IMC WITH WASHINGTON STATE AMENDMENTS, & 2018 IECC. 2. EQUIPMENT INSTALLATION INSTRUCTIONS TO BE ON SITE FOR INSPECTORS. 3. DUCT INSULATION AND SEALING TO MEET REQUIREMENTS OF SEC C403.10.1 OF THE 2018 WSEC. 4. SYSTEM CONTROLS TO MEET ALL APPLICABLE SECTIONS UNDER SEC C403.4 OF 2018 WSEC. 5. THERMOSTATS SHALL BE SET TO MAINTAIN A MINIMUM DEADBAND OF 5° F PER WSEC C403.4.1.2. 6. CONTROLS TO BE EQUIPPED WITH AUTOMATIC TIME CLOCK CAPABLE OF STARTING AND STOPPING THE SYSTEM WITH MANUAL OVERRIDE PER WSEC C403.4.2.2 7. OUTDOOR AIR SUPPLY, EXHAUST OPENING, RELIEFS TO BE PROVIDED WITH CLASS 1 MOTORIZED DAMPER AND CLOSE DURING UNOCCUPIED EQUIPMENT OPERATION PER WSEC C403.7.8.1. IF GRAVITY DAMPER, IT SHALL HAVE AN AIR LEAKAGE RATE NOT GREATER THAN 20 CFM/ FT 2. 8. VENTILATION BY MECHANICAL OR NATURAL MEANS SHALL BE NO GREATER THAN 150 PERCENT OF THE MINIMUM OA REQUIRED PER WSEC C403.2.2. 6 ALL ECONOMIZERS PROVIDED SHALL MEET SEC C403.5 OF 2018 WSEC AND BE ABLE TO PROVIDE UP TO 100 PERCENT OSA FOR COOLING PER WSEC C403.5.3.1. 10. SMOKE DETECTORS INSTALLED IN MAIN RETURN PER SEC 606 OF THE 2018 IMC. 11. ALL HVAC EQUIPMENT TO BE LABELED FOR THE SPACE SERVED. 12. DUCTS TO BE SUPPORTED AT EACH CHANGE IN DIRECTION, VERTICAL AT 12'-0" MAX, HORIZONTAL AT 10'-0" MAX WITH STRAP, OR 8'-0" MAX FROM TRAPEZE SUPPORT 13. ALL SUPPLY GRILLES TO HAVE MANUAL VOLUME DAMPERS FOR BALANCING OF SYSTEM UPON COMPLETION. 14. ALL PIPING TO BE INSULATED ACCORDING TO SECTION C403.10.3 OF 2018 WSEC. 15. FRESH AIR INTAKE AND RELIEF/ EXHAUST WILL BE EQUIPPED WITH A LOW LEAK, CLASS 1A MOTORIZED DAMPER THAT AUTOMATICALLY CLOSES DURING UNOCCUPIED HOURS TO COMPLY WITH SEC C403.7.8.1 OF 2018 WSEC 16. GAS PIPING TO BE INSTALLED IN ACCORDANCE WITH THE 2018 IFGC TABLE C404.6 WHEN APPLICABLE. 17. All EQUIPMENT SPECIFIED THE SMALLEST SIZE THAT EXCEEDS THE CALCULATED LOADS PER WSEC C403.3.1. 18. HVAC INSTALLATION SHALL BE COMPLETE WHEN ALL SECTIONS OF 408 IN 2018 WSEC HAVE BEEN SATISFIED, INCLUDING AS -BUILT DRAWINGS, SUBMITTALS, O&M MANUALS, BALANCE REPORT, AND COMMISSIONING REPORT. 1 6 FLEXIBLE INSULATED DUCTS SHALL BE MAXIMUM 5'0" LONG AND STALL MEET INSTALLATION AND MATERIAL REQUIREMENTS OF LOCAL CODES. 20. ALL BRANCH TAKE -OFFS SHALL BE PROVIDED WITH MANUAL BALANCING DAMPERS. N➢ PROPERTY SITE TENANT: EDMONDS LANDING LAND OWNER: EPC LANDLORD GROUP, LLC. 66 PARCEL NO. 2703230040 000 PROPERTY DESCRIPTION: SEC 23 TWP 27 RGE 03TH PTN OF SE1/ 4 SE1/ 4 DAF - BEG NW COR OF 3RD & DAYTON STS IN CITY OF ED TH W 338FT TO TPB TH N01*18 22E 263.88FT TH N88*41 22W 231.24FT TO ELY MGN OF SR-104 AS CONVYD TO ST OF WA PER DEEDREC AF NO'S 2141566 & 2184033 SD MGN PEING A CRV TO L HAVG A RAD OF 500FT & FR WH INT PT THEE CTR OF SD CRV BEARS S7b2*52 5 TH SLY ALG THE ARC OF SD CRVTO L & CONS A C/ AOF 0 *27 11 AN ARC DIST OF 82.4 FT TAP 10OFT ELY AS MEAS RAD TO L LN OF HWY6ENG STA 20+00 TH S23*25 27W 61.26FT TAP OPP & 80FT ELY OF HWY ENG STA 20+68.17 P.T. THS01*0 15W 80FT ELY & PLL ?FoSD L LN 106.83FT TAP OPP HWY ENG STA 21+75 TH S44*26 45E 28.10FT TAP OPP HWY ENG STA 0h& 30FT NLY AS MEAS AT R/ ATO C/ LD�YTONST TH Sff41 22E ALG NLY MGN OF6 DAYTON ST 24 4FT TO TPB EXC E 30FT PER BLA S -138 AF NO 12120410 & REV PER AF NO 605220436 SITE AREA: 1.31 ACRES USE CODE: 174 RETIREMENT HOME SCOPE OF WORK: 1. PROVIDE AND INSTALL 1 LIKE -IN -KIND FURNACE REPLACEMENT FOR FURNACE #4. INSTALL NEW CONDENSATE PUMP FOR UNIT. 2. PROVIDE AND INSTALL 1 LIKE -IN -KIND FURNACE REPLACEMENT FOR FURNACE #5. INSTALL NEW CONDENSATE PUMP FOR UNIT. 3. RECONNECT LOW VOLTAGE WIRING. SHEET INDEX 1�iNQ�nod� sy „a e wiaAe�a�°° O�ke NeTOE�eIe° ryc9c o��ooaAo. A VICINITY MAP M0.0 GENERAL NOTES & INFORMATION M1.0 SITE & MECHANICAL PLAN - FIRST FLOOR M2.0 SITE & MECHANICAL PLAN - SECOND FLOOR Z - W J O O z U O O U 06 W (DLo Z X m Q w O z a V z r) z Q J CIO C) 04 1000 z U)Q O LJ i cn Q p p Z 0 z0 W co C) C) LLJ a U) Z O V) w CV co -1- Lo 'O I- a0 N N N N O Z Q J C L a J U o in � Z Q W < Q 0 co Z cn ry a ry p LLJ LLJ mo .0 FIRST LEVEL SITE PLAN N ➢ SCALE: NOT TO SCALE FURNACE IDENTIFIER FIRST STAGE SECOND STAGE ELECTRICAL GAS TAG MAKE MODEL AIRFLOW (H/M/L) CAPACITY (BTU/HR) CAPACITY (BTU/HR) POWER SUPPLY BLOWER FLA PIPE CONNECTION SIZE (IN.) DIMENSIONS (W x H x D) (in.) WEIGHT (Ibs.) NOTES FURN-1 TRAN E A952V100CU5 VARIABLE 63,050 97,000 120-1-60 10.5 1 /2 21 x 34 x 28-3/4 145 NONE FURN-2 TRAN E A952V100CU5 VARIABLE 63,050 97,000 120-1-60 10.5 1 /2 21 x 34 x 28-3/4 145 NONE DETAIL A: MECHANICAL PLAN N➢ SCALE: 3/4" = V-0" I )# MECHANICAL NOTES = 1. ALL DUCT WORK / PIPING IS EXIST ING AND TO REMAIN. 2. LIKE-F OR -LIKE FURNACE REPLACEMENT 3 . GAS PIPING: EXISTING TO REMAIN w �< z coJ _w O O z U O O U 06 w�U) z U) 0 Qm wo z 0 z Q O Q 1000 Z cn Q � O Lv > u Q Q oz Q z0 Ljj o 0 ° w a U) Z 0 w c-1 M Lo O I-� a0 N N N N O � Z Q J O � d J ULLJ Lo O Q U) V Z Q W Q m Z � ry m 1 .0 SECOND LEVEL SITE PLAN N ➢ SCALE: NOT TO SCALE FURNACE IDENTIFIER FIRST STAGE SECOND STAGE ELECTRICAL GAS TAG MAKE MODEL AIRFLOW (H/M/L) CAPACITY (BTU/HR) CAPACITY (BTU/HR) POWER SUPPLY BLOWER FLA PIPE CONNECTION SIZE (IN.) DIMENSIONS (W x H x D) (in.) WEIGHT (Ibs.) NOTES FURN-1 TRAN E A952V100CU5 VARIABLE 63,050 97,000 120-1-60 10.5 1 /2 21 x 34 x 28-3/4 145 NONE FURN-2 TRAN E FA952V100CU5 VARIABLE 63,050 97,000 120-1-60 10.5 1 /2 21 x 34 x 28-3/4 145 NONE #O MECHANICAL NOTES = 1. ALL DUCT WORK / PIPING IS EXISTING AND TO REMAIN. 2. LIKE-F OR -LIKE FURNACE REPLACEMENT 3. GAS PIPING: EXIST ING TO REMAIN DETAIL B: MECHANICAL PLAN N� SCALE: 3/4" = 1 ' 0" C QQ L ZO QN L.Lj o 0 ° w 0 z O w cl� - CV CM -;T Lo 'O I, aO N T N N N O aCj1 U 04 Z Q O � J � Lo d O Lf) J V ULLJ Z Q Q m Q Z W Q ry � :�i cn a Q M 2 .0 cn