Loading...
ENG2022-0217 ROW PERMITRIGHT OF WAY EUC ••City of Edmonds PERMIT NUMBE Elk Description: COMCAST-OVERLASH AND PULL FIBER THROUGH EXISTING CONDUIT ISSUED: 07/18/2022 Address: 600 MAIN ST EDMONDS WA 98020-3079 EXPIRES: 01/18/2023 Permit Type: RIGHT OF WAY EUC Permit Subtype: MINOR Parcel Number: 00434209700100 CONTACTS NAME TYPE NAME ADDRESS PHONE APPLICANT JESSAMIN SANTOS 410 VALLEY AVE NW, PUYALLUP WA 98371 (206)401-2188 CONTACT CCI SYSTEMS 105 KENT ST, IRON MOUNTAIN MI49801 (615)962-4402 CONTRACTOR CABLECOM LLC 20021 120TH AVE NE„ BOTHELL WA 98011 (360)622-5388 OWNER 600 MAIN STREET LLC 710 WALNUT ST, EDMONDS WA 98020-3422 FEE INFORMATION DESCRIPTION AMOUNT PAID CITY TECHNOLOGY FEE CHARGED PER PERMIT $40.00 $40.00 ENGINEERING INSPECTION FEE $110.00 $110.00 RIGHT OF WAY MINOR - EUC PERMIT FEE $110.00 $110.00 REQUIREMENTS REQUIREMENT TYPE NOTES TRAFFIC CONTROL Traffic control and public safety shall be in accordance with City regulations as required by the City Engineer. Every flagger must be trained as required by WAC 296-155-305 and must have certification verifying completion of the required training in their posession. RESTORATION Restoration is to be in accordance with City codes. All street -cut trench work shall be patched with asphalt or City approved material prior to the end of the workday - No Exceptions WARRANTY The contractor is responsible for workmanship and materials for a period of one year following the final inspection and acceptance of the work. INSPECTION SCHEDULING: WWW.MYBUILDING PERMIT.COM 24 HR NOTICE REQUIRED The Applicant has signed an application which states he/she holds the City of Edmonds harmless from injuries, damages or claims of any kind or description whatsoever, foreseen or unforeseen, that may be made against the City of Edmonds or any of its departments or employees, including but not limited to the defense of any legal proceedings including defense costs and attorney fees by reason of granting this permit. THIS DOCUMENT IS NOT VALID UNTIL FEES ARE PAID AND THE CITY ENGINEER OR HIS/HER DEPUTY HAS SIGNED BELOW 07/18/2022 RELEASED BY DATE Printed: Monday, July 18, 2022 1:39:43 PM 1 of 2 QF E ISM RIGHT OF WAY EUC PERMIT PERMIT NUMBER, City of Edmonds AM Edmonds WA 98020 CONDITIONS CONDITION TYPE NOTES ALERT RESIDENTS ALERT AFFECTED RESIDENTS AND OR BUSINESSES PRIOR TO WORK START. It is the owner's responsibility to repair/replace all damage of utilities or frontage improvements in DAMAGE TO FRONTAGE City right of Ways or Easements to City Standards caused by or occurring during the permitted IMPROVEMENTS project. MAINTAIN EROSION AND SEDIMENTATION CONTROL PER CITY AND SWMMW STANDARD ESC REQUIREMENTS REQUIREMENTS. Applicant, on behalf of his or her spouse, heirs, assigns, and successors in interests, agrees to indemnify defend and hold harmless the City of Edmonds, Washington, its officials, employees, and agents from any and all claims for damages of whatever nature, arising directly or indirectly from the HOLD HARMLESS issuance for this permit. Issuance of this permit shall not be deemed to modify, waive or reduce any requirements of any City ordinance nor limit in any way the City's ability to enforce any ordinance provision. SCHEDULE REQUIRED INSPECTIONS AS NOTED THROUGH MY BUILDING PERMIT. INSPECTIONS www.mybuildingpermit.com POTHOLING VERIFY CLEAR BORE CROSSINGS. RESTORE LANDSCAPE Restore landscape to like or better conditions Sound or noise originating from temporary construction sites as a result of construction activity are exempt from the noise limits of ECC Chapter 5.30 only during the hours of 7:00am to 6:00pm on SOUND AND NOISE weekdays and 10:00am and 6:00pm on Saturdays, excluding Sundays and Federal Holidays. At all other times the noise originating from construction sites and activities must comply with the noise limits of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120. All utilities shall be located prior to any excavation. New locates shall be called for if at time of UTILITY LOCATES excavation, original locates are no longer identifiable. INSPECTIONS INSPECTION TYPE DATE RESULT NOTES COMPLETE A-1 JOB START X-2 ENGINEERING FINAL" E-7 TRAFFIC CTRL Printed: Monday, July 18, 2022 1:39:43 PM 2 of 2 ofEOMotio� RECEIVED RIGHT OF WAY CONSTRUCTION J U N 08 2022 PERMIT APPLICATION Complete and submit this Application in accordance with the Submittal CITY OF EDMONDS zDEVELOPMENT /'V . i?`)3 Requirements outlined in Right -of -Way permit Handout E6�. SERVICES DEPARTMENT If any field is not applicable to your project, write "N/A' instead of leaving blank. All fields required. Incomplete Applications will be denied. SECTION A General • Project Name JB-loo0393 Site Address or if no site address use Property Address at NW corner of project area: 600 MAIN ST, STE A, EDMONDS ,WA 98020 Associated Permits: BLD PLN ENG Owner and Entity Holding Name of Company Comcast Cable Communications Management, LLC. Franchise Ordinance No: Point of Contact Jessamin Santos Title Permit Coordinator Address 410 Valley Ave NW City Puyallup State WA Zip 98371 Phone (2o6) 401-2188 Email jessamin_santos@cable.comcast.com Contractor and Authorized Agent of Owner Name of Company Cablecomm, LLC (see note below) Contractor Contacts During Construction Primary Name CHRIS ATKINSON Agent Name Lena Tofaeono Title Construction Supervior Title Permit Coordinator Mobile 36o-926-3437 Address 2002112oth Ave NE, Bldg P Ste 1o1, Email CHRIS.ATKINSON@CABLECOMLLC.NET City Bothell State wA Zip 98011 Secondary Name Phone 36o-622-5388 Title Email leua.tofaeono@cablecomllc.net Mobile City of Edmonds Business License No: NR-o21818 Email State License No: CABLE-971DP ® Contractor verifies it is currently bonded ® Contractor verifies it currently has general liability insurance NOTE: ECDC18.6o.o2o requires that the Application be signed by a licensed and bonded contractor unless otherwise approved by the city engineer. ❑ Multifamily residential ❑ Commercial ❑ City project ❑ Single family residential subdivision ❑ Single family -other ❑ Industrial ❑ Demo and rebuild or from vacant land? ❑ Other, please specify: ❑ Utility Franchise Work associated with development (check one of the above boxes as welt ❑ Traffic Control Only (no associated development) X Utility Franchise Work (no associated development) City of Edmonds ROW construction permit Application --Page 1 of 3 Updated 3/25/2021 Include an overall narrative description of the proposed work. Be specific and detailed: Describe infrastructure to be impacted, such as, poles, wires, conduit, utility mains, etc. Include whether this is construction, maintenance, or repair. Include description of proposed construction methods, (e.g., bores, trenches, overhead wires proposed, depth for underground utilities, etc.) Comcast JB i000393: The proposed in the ROW is to overlash up to 57o' of 96ct fiber to existing Comcast strand; along the east side of 6th Ave S running north to riser pole; proof existing riser / buried conduit and pull new 12ct fiber 102' from ROW to private to address 600 MAIN ST, EDMONDS, WA 98020. * No disturbance of surface. RIGHT-OF-WAY CLOSURE AREA TOTAL DURATION (Number of Months) Sidewalk 72 hours + LF x LF SF NA Alley 72 hours + LF x LF SF NA Parking 72 hours + LF x LF SF NA SECTION B - If you are not a utility company performing work in the City ROW, skip to SECTION C. 1. The work in the right of way is on or for the following type of facilities: ❑ telecommunications X cable (fiber) ❑ power ❑ gas ❑ water ❑ sewer ❑ storm Details of Work to be Completed 1. Does the utility owner have existing overhead infrastructure in the area of work? Yes No X 2. Will any equipment be added underground or above ground (e.. pedestals, vaults, etc.)? X If yes, describe: 3. Does the proposed work connect a lot or commercial development with utilities that serve more than one lot or commercial development? X 4. Does the work involve rebuilding or relocating an existing aboveground utility system which connects a lot or commercial development to an existing underground common utility stem? X 5. Does the work involve proposed additions to an aboveground utility stem? If es: X Are the additions for the purpose of serving new commercial development? X Are the additions for the purpose of serving a single-family residential subdivision? X Details of Work to be Completed Yes No 6. Does your project involve rebuilding or replacing utility equipment which currently serves more than one lot or commercial development? If yes, answer the following questions related to project area, i.e. the actual area in which the X project is proposed: 6a. Does your project involve wires/cables/lines? If yes: X How many are existing? 1 1-2 1How many are to be added? 1 City of Edmonds ROW construction permit Application --Page 2 of 3 Updated 3/25/2021 6b. Does your project involve poles? If yes: X How many poles are existing in the project area? 5 What is the height of the existing poles? 45' to 55 How many poles are to be removed? o Are additional poles to be laced? X How many? I I What is the height of the additionalpoles? 6c. Are any poles to be modified/rebuilt/replaced? If yes: X How many? I I What is the height of the poles after? Describe the modification rebuild: SECTION C Traffic Control and Public Safety. Traffic control and public safety shall be in accordance with City regulations as required by the City Engineer. Every flagger must be trained as required by WAC 296-155-305 and must have certification verifying completion of the required training in their possession. Restoration. Restoration shall be in accordance with City codes and Standards. All street cut trench work shall be patched with asphalt or City approved material prior to the end of the workday -NO EXCEPTIONS. Insurance. The City may require the owner or contractor to provide proof of insurance acceptable to the City prior to any permit approval. Indemnification. The Applicant agrees to defend, indemnify, and hold harmless the City of Edmonds, its officials, officers, employees, and agents against any injuries, damages, or claims of any kind or description whatsoever, foreseen or unforeseen, including defense costs and attorney fees, resulting directly or indirectly from any act or omission of the Applicant, its subcontractors, anyone directly or indirectly employed by them, and anyone for whose acts or omissions they may be liable, arising out of, related to, or by reason of the granting of this permit; and specifically including but not limited to all loss by the failure of the Applicant to fully or adequately perform, in any respect, all authorizations or obligations under the permit. These indemnification requirements shall survive the expiration, revocation, or termination of any resulting permit approval. Acceptance of terms, conditions, and requirements. Applicant accepts the terms, conditions, and requirements set forth in this Application and agrees they apply to any resulting permit and shall comply with them to the satisfaction of the City Engineer. Applicant further agrees to comply with the conditions listed on the Submittal Requirements; with all applicable city ordinances, including but not limited to ECDC Title 18; and with all applicable requirements of state and federal law. Statement of Applicant. I declare under penalty of perjury under the laws of the State of Washington that: I am a licensed and bonded contractor; the information provided herein is correct and complete; and I am authorized by owner to act on its behalf and have authority to bind the owner to this application. Fees. The Applicant is responsibleforall permit fees. APPLICANT SIGNATURE: Je SaW(n , Saht0S APPLICANT PRINTED NAME: Jessamin Santos APPLICANT TITLE: Permit Coordinator NO WORK SHALL BEGIN PRIOR TO PERMIT ISSUANCE 5/6/2022 City of Edmonds ROW construction permit Application --Page 3 of 3 Updated 3/25/2021 Route Overview COMICAST Legend New Ped Pole New Vault ❑v Lock Box Existing U/G Footage Existing Aerial Text Box New U/G Callout Arrow New Aerial New Tap Interior Path Footage Break Phase Identifier Fiber Splice Point Power Supply Storage Loop Hard Surface Cut Riser R Abandoned Cable Provide Clear Construction Details 1. TIE POINT AT AERIAL SP.WALY.0421_ LY07MS1.5A.1A - INSTALL STRAP OUT CASE - 158' ROW AERIAL 96C FOC DELASH / RELASH - 112' ROW AERIAL 96C FOC DELASH / RELASH - 185' ROW AERIAL 96C FOC OVERLASH (FLYING DUTCHMAN) - 115' ROW AERIAL 96C FOC OVERLASH - INSTALL ENCLOSURE TO TRANSITION 96C TO 12C FOC 2. 25' ROW RISER 12C FOC CONDUIT PULL (EXISTING 2" CONDUIT PROOF AND PULL) - 102' ROW TO PRIVATE EXTERIOR 12C FOC CONDUIT PULL TO BREAKOUT (EXISTING 2" CONDUIT PROOF AND PULL) - 25' PRIVATE EXT 12C FOC CONDUIT PULL S (EXISTING 2" CONDUIT PROOF AND PULL) - 20' RISER PRIVATE EXT / INT 12C FOC CONDUIT PULL TO 2ND FLOOR MECH ROOM (EXISTING 2" CONDUIT PROOF AND PULL) - 15' PRIVATE INT 12C FOC ON WALL - INSTALL SPLIT DUCT - INSTALL 2' X X PLYWOOD AND (IM) ON WALL ***ROUTE OVERVIEW CONTINUED ON TAB (2)*** Completed By: Completion Date: Survey Revision Date: Survey Revision Task ID: Engineered For: Project Manager: P2 ID: W.PASCHAL 4/26/2022 Address: 600 MAIN ST STE A EDMONDS WA 98020 Footages Entered On Right of Way, Private Exterior, and Private Interior tabs. Footages are summarized on Survey Rollup tab. JB0001000393 Are Additional Pages Needed: �• r 115'IN 2ND FLOOR MECHANICAL ROO TO 1ST FLOOR ELECTRICAL CLOSET i t �lv 38' THRU 1ST FLOOR DROP PANEL CEILING TO SERVER ROOM IN STE A - 3 EXISTING POE IN SHEETROCK T 1 10' IN SERVER ROOM TO RACK - INSTALL EQUIPMENT 4 1 .c Vr4LY C AVAILABLE 110 VAC ON WALL ❑1 �1' 115' PS O FLYING DUTCHMANF "_ r 4 w r .. • RECEIV�D ( - JUN 08 20 2 - -'�- CITY OF EDMON S DEVELOPMEN ERVICES DEPARTI 4ENT • 1 W No 2 15' IN 2ND FLOOR MECHANICAL ROOM & INSTALL 2' X 3' PLYWOOD & (IM) ON WALL 2 25' & 20' RISER TO 2ND FLOOR MECHANICAL ROOM TS'R ' EXTERIOR BREAKOUT MM D INSTALL ENCLOSURE TO TRANSITION 96C TO 12C FOC -_M 185' 0 1 W. I WASNEM018 N S ENGINEERING DIVISION ,.., DTED 17/ 15/2 WASNEM011 �E All Applicant shall repair/replace all INSTALL STRAP damage to utilities or frontage improvements in City right-of-way OUT CASE per city standards that is caused or occurs during the permitted project. TIE POINT @ SP.WALY.0421_ LLY07MS1.5A.1A OWNER/CONTRACTOR IS RESPONSIBLE FOR EROSION CONTROL AND DRAINAGE Route Overview %f COMCAST Legend New Ped Pole New Vault ❑v Lock Box Existing U/G Footage Existing Aerial Text Box New U/G Callout Arrow New Aerial New Tap Interior Path Footage Break Phase Identifier Fiber Splice Point Power Supply Storage Loop Hard Surface Cut Riser Abandoned Cable Completed By: Completion Date: Survey Revision Date: Survey Revision Task ID: Engineered For: Project Manager: P2 ID: 150' Text R Provide Clear Construction Details 3. 15' PRIVATE INT 12C FOC IN MECHANICAL ROOM - PULL TO 1ST FLOOR ELECTRICAL CLOSET - 38' PRIVATE INT 12C FOC FROM 1ST FLOOR ELECTRIC CLOSET THRU DROP PANEL CEILING VOID TO POE INTO SERVER ROOM (POE - EXISTING 3" HOLE IN SHEETROCK) - INSTALL SPLIT DUCT 4. 10' PRIVATE INT 12C FOC IN SERVER ROOM TO WALL MOUNTED DATA RACK - INSTALL EQUIPMENT IN RACK - AVAILABLE 110 VAC ON WALL BELOW RACK RECEIVED JUN 08 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Im W.PASCHAL 4/26/2022 Address: 600 MAIN ST STE A EDMONDS WA 98020 Footages Entered On Right of Way, Private Exterior, and Private Interior tabs. Footages are summarized on Survey Rollup tab. JB0001000393 Are Additional Pages Needed: 15' IN 2ND FLOOR MECHANICAL R00 TO TLOOR EIECTRICAIOT 1SSE /hl E Flv 38' THRU 1ST FLOOR DROP PANEL 3 CHUNG TO SERVER ROOM IN STE A - EXISTING POE IN SHEETROCK T 10' IN SERVER ROOM TO RACK - INSTALL EQUIPMENT a t �-,%.. . AVAILABLE 110 VAC ON WALL l FLYING DUTCHMAN ' I ' W No z 15' IN 2ND FLOOR MECHANICAL ROOM & INSTALL 2' X 3' PLYWOOD & (IM) ON WALL Z 25' & 20' RISER TO 2ND FLOOR MECHANICAL ROOM 102' EXTERIOR BREAKOUT 25' R 2 INSTALL ENCLOSURE TO 115 I TRANSITION 96C TO 12C FOC • am --A e no 112' Q.� m - -_ P158. 41 ri> I WASNEM018 r WASNEM011 „ INSTALL STRAP OUT CASE I TIE POINT @ err SP.WALY.0421 �•-. LY07MS1.5A.1A N S E Right of Way COMCAST Completed By: Completion Date: Survey Revision Date: Survey Revision Task ID: Engineered For: Project Manager: P2 ID: Legend New Ped ❑ Pole New Vault v Lock Box Existing U/G Footage 150' Existing Aerial Text Box Text New U/G Callout Arrow New Aerial New Tap ._ Interior Path i Footage Break Phase Identifier T Fiber Splice Point Power Supply Storage Loop M Hard Surface Cut • Riser Ow Abandoned Cable Provide Clear Construction Details 1. TIE POINT AT AERIAL SP.WALY.0421_ LY07M S 1.5A.1 A , - INSTALL STRAP OUT CASE - 158' ROW AERIAL 96C FOC DELASH / RELASH RECEI' - 112' ROW AERIAL 96C FOC DELASH / RELASH - 185' ROW AERIAL 96C FOC OVERLASH JUN 08 (FLYING DUTCHMAN) - 11 5'ROW AERIAL 96C FOC OVERLASH - INSTALL ENCLOSURE TO TRANSITION 96C CITY OF EDN TO 12C FOC DEVELOPV SERVICES DEP) 2. 25' ROW RISER 12C FOC CONDUIT PULL (EXISTING 2" CONDUIT PROOF AND PULL) - 102' ROW TO PRIVATE EXTERIOR 12C FOC CONDUIT PULL TO BREAKOUT (EXISTING 2" CONDUIT PROOF AND PULL) - 25' PRIVATE EXT 12C FOC CONDUIT PULL (EXISTING 2" CONDUIT PROOF AND PULL) - 20' RISER PRIVATE EXT / INT 12C FOC CONDUIT PULL TO 2ND FLOOR MECH ROOM (EXISTING 2" CONDUIT PROOF AND PULL) - 15' PRIVATE INT 12C FOC ON WALL - INSTALL SPLIT DUCT • - INSTALL 2' X T PLYWOOD AND (IM) ON WALL W.PASCHAL 4/26/2022 JB0001000393 1 Address: New Aerial Coax: 0 New Aerial Fiber: 570 Empty Conduit Only: 0 Are Additional Pages Needed: TIE POINT @ SP.WALY.0421_ - LY07MS1.5A.1A ■ 600 MAIN ST STE A EDMONDS WA 98020 Right of Way Footages: Overlash Coax: 0 New UG Fiber: 0 Overlash Fiber: 0 Existing LIG Fiber: 0 New UG Coax: 0 Existing UG Coax: 0 No TIE POINT @ SP.WALY.0421_ I NSTAII STRAP LY07MS1.5A.1A OUT CASE s �158' 112' f Right of Way Completed By: W. PASCHAL Address: 600 MAIN ST STE A EDMONDS WA 98020 Completion Date: 4/26/2022 Right of Way Footages: Survey Revision Date: New Aerial Coax: 0 Overlash Coax: 0 New UG Fiber: 0 Survey Revision Task ID: New Aerial Fiber: 570 Overlash Fiber: 0 Existing UG Fiber: 0 COMCAST Engineered For: Project Manager: Empty Conduit Only: 0 New UG Coax: 0 Existing UG Coax: 0 P2 ID: JB0001000393 Are Additional Pages Needed: No Legend New Ped ❑ Pole 6� INSTALL ENCLOSURE TO New Vault ❑� Lock Box TRANSITION 96C TO 12C FOC Existing U/G Footage 150' Existing Aerial Text Box Text 115 New U/G Callout Arrow New Aerial f New Tap Interior Path _ Footage Break Phase Identifier 0 Power Su I Fiber Splice Point Supply Ps 115' TARGET 25' R Storage Loop co Hard Surface Cut 0 � • 1 Riser O Abandoned Cable Provide Clear Construction Details- 1. TIE POINT AT AERIAL SP.WALY.0421_' LY07MS 1.5A.1 A - - INSTALL STRAP OUT CASE - 158' ROW AERIAL 96C FOC DELASH / RELASH INSTALL ENCLOSURE TO - 112' ROW AERIAL 96C FOC DELASH / RELASH TRANSITION 96C TO 12C FOC - 185' ROW AERIAL 96C FOC OVERLASH (FLYING DUTCHMAN) RECEIVED 115 - 115' ROW AERIAL 96C FOC OVERLASH JUN 08 2022 - INSTALL ENCLOSURE TO TRANSITION 96C TO 12C FOC 2. 25' ROW RISER 12C FOC CONDUIT PULL (EXISTING 2" CONDUIT PROOF AND PULL) CITY OF EDMONDS DEVELOPMENT EXTERIOR 25' R - - 102' ROW TO PRIVATE EXTERIOR 12C FOC SERVICES DEPARTMENT BREAKOUT � CONDUIT PULL TO BREAKOUT (EXISTING 2" CONDUIT PROOF AND PULL) _ - 25' PRIVATE EXT 12C FOC CONDUIT PULL (EXISTING 2" CONDUIT PROOF AND PULL) TARGET STRUCTURE - 20' RISER PRIVATE EXT / INT 12C FOC z ' CONDUIT PULL TO 2ND FLOOR MECH ROOM (EXISTING 2" CONDUIT PROOF AND PULL) 2° CONDUIT ROUTED TO - 15' PRIVATE INT 12C FOC ON WALL 102 _.• TARGET STRUCTURE - INSTALL SPLIT DUCT - INSTALL 2' X T PLYWOOD AND (IM) ON WALL L1 C BUFFER DATA LONGITUDINAL BUFFER SPACE = B SPEED (MPH) 25 30 35 40 45 50 55 60 65 ]o LENGTH (feet) 155 200 250 305 360 — -- — — -- TMA ROLL AHEAD DISTANCE = R HOST VEHICLE WEIGHT 9,900 TO 22,000 IDS. HOST VEHICLE WEIGHT > 22,000 Ibs. <45 MPH 45-55 MPH > 55 MPH <45 MPH 45-55 MPH > 55 MPH 100' 74' PROTECTIVE VEHICLE (WORK VEHICLE) = R NO SPECIFIED DISTANCE REQUIRED 6TH AVE S a a X X i ID SIGN SPACING = X (FEET) ( 1 ) RURAL ROADS & URBAN ARTERIALS 35 140 MPH 350't RURAL ROADS, URBAN ARTERIALS 25130 MPH RESIDENTIAL & BUSINESS DISTRICTS 200't (2) URBAN STREETS 25 MPH OR LESS 100't (2) ALL SIGNS ARE 48" x 48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED. MINIMUM SHOULDER TAPER LENGTH = U3 (feet) SHOULDER Pueted Speed (mph) WIDTH ('0 25 1 30 I 35 1 40 45 50 55 fi0 65 ]D e' 40 40 60 98 120 130 150 1fi0 1]0 190 1a 4o fio 90 ao 15o no 190 2ao 220 240 USE A MINIMUM 3 DEVICES TAPER FOR SHOULDER LESS THEN 8'. (1) All spacing may be adjusted to accommodate interchange ramps, at -grade intersections, and driveways. (2) This spacing may be reduced in urban areas to fit roadway conditions. Spotter to assist pedestrians through work zone -- -- - - I © O WORK AREA 1/3 B R 100' ROAD SHOULDER WORK no Contractor to p parking g post arkin signs WORK AHEAD 72hrs in advance for road side parking along east side of 6th Ave S where W20-1 W21-5 applicable for pole access CHANNELIZING DEVICE SPACING (FEET) MPH TAPER TANGENT 35140 30 1 60 25/30 20 1 40 Z� NOTE 1. When used, device spacing for the downstream taper should be 20' O.C. LEGEND ENGINEERING DIVISION ® N SIGN LOCATION """ r" "" ""OTED CHANNELIZING DEVICES RECEIVED PROTECTIVE VEHICLE - RECOMMENDED _ fI� 17/15/2022 JUN 08 2022 Applicant shall repair/replace all damage to utilities or frontage TYPICAL SHOULDER CLOSURE - LOW SPEED (40 MPH OR LESS) improvements in City right-of-way TCP 5 CITY OF EDMONDS per city standards that is caused or OWNER/CONTRACTOR IS RESPONSIBLE FOR DEVELOPMENT occurs during the permitted project. SERVICES DEPARTMENT EROSION CONTROLAND DRAINAGE n 0 Ln n /Sv VJ O s= s? (D C7 0 (n (D I 1- 0 W (D (D a CD ZT 0 r (D (n N ONE LANE ROAD AHEAD WORK ZONE CONDITION (SEE CHAPTER 1.9.10) A - ALLOWED - CONSIDER USING A SPOTTER. ROAD N0R AHEAD B - ALLOWED - SPOTTER RECOMMENDED Q m CONSIDER ADDITIONAL WARNING SIGNS. BE ro STEP C - NOT ALLOWED - SEE TCP 14 & 15 FOR ADDITIONAL WORK ZONE REQUIREMENTS. Flagg ers to maintain one lane of traffic for O overlash crossing at 6th Ave S & Maple St. ONE LANE ROAD AHEAD ------------------ � 7,xx BE WORN PREPARED . AHEAD TO STOP Spotter to assist pedestrians through work zone ® WORK VEHICLE W/ WARNING BEACON ¢ (LOCATE TO SHIELD WORK VEHICLE) ONE LANE OS SPOTTER ROAD AHEAD RECEIVED JUN 08 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SIGHT DISTANCE DATA MINIMUM STOPPING SIGHT DISTANCE = S SPEED LIMIT 25 30 35 40 45 50 55 60 65 70 MPH DISTANCE FEET 155 200 250 305 360 425 495 570 645 730 DISTANCES SHOWN ARE MINIMUMS, USE ADDITIONAL DISTANCE WHEN POSSIBLE. ONE LANE GENERAL LIMITS OF ROAD AHEAD CHANNELIZED INTERSECTION ROAD.. . PREPMED WORK TO ETOP AXEAD WORK -- ----- --------------------------- AREA 6TH AVE S I� NOTES: 1. Work vehicle w/beac n located in same quadrant t as work location. */TM, 2. Repeated access to work lane not allowed. see tcp 14 & 15 for work zone requirements - condition "C". ROAD 3. READ Restricted sight distance requires additional advance AWX warning devices or signs, see sight distance data chart. 4. Recommend working during red phase if signalized. 5. See chapter 1.9.10 - 1.9.11 for additional direction . "ROAD WORK AHEAD" signs to be TYPICAL VERY SHORT DURATION WORK OPERATION (INTERSECTION APPLICATION) placed on all public road approaches to TCP 29 work area or advance sign area. ONE LANE ROAD AHEAD WORK ZONE CONDITION (SEE CHAPTER 1.9.10) �' _ ROAD A - ALLOWED - CONSIDER USING A SPOTTER. c A; 0 T B - ALLOWED - SPOTTER RECOMMENDED o 0 CONSIDER ADDITIONAL WARNING SIGNS. RE PREPARED C - NOT ALLOWED - SEE TCP 14 & 15 FOR N SNP ADDITIONAL WORK ZONE REQUIREMENTS. Flagg ers to maintain one lane of traffic for O overlash crossing at 6th Ave S & Dayton St. ONE LANE ROAD AHEAD ----------------- W0—AR.'.Ov, RoAD Spotter to assist pedestrians through work zone I Fr_FNn ® WORK VEHICLE W/ WARNING BEACON ¢ (LOCATE TO SHIELD WORK VEHICLE) OS SPOTTER RECEIVED JUN 08 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT TYPICAL VERY SHORT DURA (INTERSECTION A TCP 2 ONE LANE ROAD AHEAD SIGHT DISTANCE DATA MINIMUM STOPPING SIGHT DISTANCE = S SPEED LIMIT 25 30 35 40 45 50 55 60 65 70 MPH DISTANCE FEET 155 200 250 305 360 425 495 570 645 730 DISTANCES SHOWN ARE MINIMUMS, USE ADDITIONAL DISTANCE WHEN POSSIBLE. ONE LANE ROAD AHEAD GENERAL LIMITS OF CHANNELIZED INTERSECTION .� _'a PREPARED 0 < RWORK wzi-a N STOP AXEAD WORK -- ----- --------------------------- AREA 6TH AVE S �o' L NOTES: 1. Work vehicle w/beacon located in same quadrant as RE work location. PREPARED D S DP 2. Repeated access to work lane not allowed. see tcp WORK OPERATION ;ATION) 14 & 15 for work zone requirements - condition "C". 3. Restricted sight distance requires additional advance warning devices or signs, see sight distance data chart. 4. Recommend working during red phase if signalized. 5. See chapter 1.9.10 - 1.9.11 for additional direction . "ROAD WORK AHEAD" signs to be placed on all public road approaches to work area or advance sign area.