BLD2022-0961_Site_Plan_7.19.2022_12.02.25_PM_2998244Equipment Summary
Modules:
(25) Solaria 40OW
Inverter(s):
(1) SolarEdge 760OH-US
Racking:
Ironridge XR100
Table of Contents:
Cover Page
Al Site Overview
A2 Roof Layout
E1 Single Line
E2 Electrical Calculations
G1 Roof As Built
G2 Electrician As -Built
G3 Micro/optimizer map
G4 Placards
GS Equipment BOM
General Notes:
Additional Electrical Work:
4
Site
Net Meter
A&RSOLAR
3211 Martin Luther King Jr Way S.
Seattle, WA 98144 (206)707-9937
THIS DRAWING CONSTITUTES THE
CONFIDENTIAL INFORMATION OF A&R SOLAR
AND ITS RECEPTOR. POSSESSION DOES NOT
CONFER ANY RIGHT IN OR LICENSE TO USE IT
OR THE INFORMATION DISCLOSED HEREIN
NOR ANY RIGHT TO REPRODUCE THIS
DRAWING OR ANY PART HEREIN WITHOUT
THE WRITTEN CONSENT OF A&R SOLAR.
OQ
O
(A
Z�
N
_
p00
f
M(/)00
"o
(V
Q)
0r
ON
�In>a
��Q
o
�
�
N
No
Q
�
n
_0
Cc
O
N
O
O
-0
L.
O
LV
a
�
REVISIONS
Rev. #: IDate:
Designed by: Thomas N
Project Manager:
Arthur Eith
(612) 298-1795
Current Date:Jul 07, 2022
Cover Page
Modules not to exceed height of existing ridge
Inverter, AC Disconnect,
Customer Owned Production Meter
N
Net Meter
0 MS
Attachment Detail
Side View (Portrait)
FLASHING AS REQUIRED
TO SEAL ROOF
MINIMUM (1) 5/16 X 4.75 LAC
BOLT EMBEDDED 2" MINIMUM
CENTER ON ROOF FRAMINC
PV MODULE,
BY OTHERS
IRONRIDGE
RAIL
(E) COMPOSITION
SHINGLE ROOF
IRONRIDGE
FLASHFOOT2
(E) ROOF FRAMING
— — — — — — — — — — — — — — — — — — — — — —
116"
Building height
I
Manufactured trusses,
24" O.C.
(sample) Attachment point layout for array.
48" OC Max.
A&RSOLAR
3211 Martin Luther King Jr Way S.
Seattle, WA 98144 (206)707-9937
THIS DRAWING CONSTITUTES THE
CONFIDENTIAL INFORMATION OF A&R SOLAR
AND ITS RECEPTOR. POSSESSION DOES NOT
CONFER ANY RIGHT IN OR LICENSE TO USE IT
OR THE INFORMATION DISCLOSED HEREIN
NOR ANY RIGHT TO REPRODUCE THIS
DRAWING OR ANY PART HEREIN WITHOUT
THE WRITTEN CONSENT OF A&R SOLAR.
OQ
O
(/i
>
N
_
0��000
�
0
U>(V
Q)0r
ON
CIn>a
Ewa
o
�
�
N
No
Q
�
^
-0
ru
O
N
p
.O
in-
E
o
'N
-o
L.
01
LU
aT--1
REVISIONS
Rev. #: I Date:
Designed by: Thomas N
Project Manager:
Arthur Eith
(612)298-1795
Current Date:3ul 07, 2022
Al Site
Overview
Required Setbacks from Ridge:
18.,
Maximum Mount Spacing:
48^
Roof Type:
Membrane
Roof Slope:
100
Array Tilt :
Flush
Array Azimuth(s):
900,2700
Roof Area:
3278ft2
Array Area
533ft2
Array to Roof Coverage
16%
***Roof Attachments/ Fastners; see pg. G5 Equip. BOM * * *
"All
'B"
Net Meter
Module and Rail Selection Guide
Solaria 40OR-PM
47.4 x 64.72
Clamp Zone "A"
0-10.98"
Clamp Zone "B"
10.98-16.97"
Mods per Row
Rail typel+ rail type2
(6)Portrait, (2)rows
(2)14', (2)14'
(5)Portrait, (2)rows
(2)14', (2)split 14'
(2)Portrait, (1)row
(2)14',
(1)Portrait, (1)row
(2)split 14',
_ I
A&RSOLAR
3211 Martin Luther King Jr Way S.
Seattle, WA 98144 (206)707-9937
THIS DRAWING CONSTITUTES THE
CONFIDENTIAL INFORMATION OF A&R SOLAR
AND ITS RECEPTOR. POSSESSION DOES NOT
CONFER ANY RIGHT IN OR LICENSE TO USE IT
OR THE INFORMATION DISCLOSED HEREIN
NOR ANY RIGHT TO REPRODUCE THIS
DRAWING OR ANY PART HEREIN WITHOUT
THE WRITTEN CONSENT OF A&R SOLAR.
OQ
O
(/i
>
N
O
to
N
Q)
a)
O
s=M
Ewa
>a
o
�
�
N
Q
�
No
-v
3z
O
N
p
.O
6
�O
E
O
-0
L.
O
LV
aT-4
REVISIONS
Rev. #: I Date:
Designed by: Thomas N
Project Manager:
Arthur Eith
(612)298-1795
Current Date:3ul 07. 2022
A2 Roof Layout
I
I
I
Line
0
String 1
—
+�XDX,
13 modules
+
z
o
V
-------------------
----
Load
String 2
�
U
o
12 modules
+
5
�
I — —
0 0
Ac
Co -Located
with Net Meter Customer Owned
(less than 10' away) Production Meter
0 Equipment Schedule
Ref.
Category
Equipment
QTY
1
Modules
Solaria 40OR-PM
25
2
Optimizers
S440 SolarEdge Optimizer
25
3
Jbox
Jbox
3
4
Inverters
Solar Edge SE7600H
1
5
Disconnect
60A 600V 2 Pole I Heavy Duty, No Fuse, Lockable
1
6
MeterBase
MeterBase-125A 4 Jaw w/ 3.5" AWCAP
1
Meter
Landis Gyr EA110000-OP29 240V
1
Monitoring
SolarEdge Integrated (inverter) Monitoring
1
0 1conductor Schedule
■=A&RScope `„I'
= Existing or A&RSOLAR
Others Scope
3211 Martin Luther King Jr Way S.
Seattle, WA 98144 (206)707-9937
(Existing)
Main Service Panel
(lph 240V Service)
Main Breaker: 200A
Bus Rating:200A
Solar OCPD: 2p40A
I nverter Specs
Watts
Lw—1
Output
LAI
AC
Voltage
# of
Inverters
OCPD
Solar Edge SE7600H
7600
32
240
1
40
****N/A****
0
0
0
0
0
****N/A****
0
0
0
0
0
Module Specs
Watts w
Imp
Vmp
Voc
Isc
Solaria 40OR-PM
400
9.41
42.4
51.1
9.82
Temp. Adjusted
1 0
1 0
1 36.8
55.8
0
Summary
Distance (ft)
Current
@125%
Operating
Voltage
Voltage
Drop
Volt. Drop
(total)
A
(2)#10 CU, (1)#6 EGC, PV Wire 60OV, AIR
50
18.75A
400V
0.40%
1.22%
B
(4)#10 CU, (1)#10 EGC, THWN-2, 0.75"EMT(min)
50
18.75A
400V
0.40%
C
(2)#8 CU, (1)#8 N, (1)#10 EGC, THWN-2, 0.75"EMT(min)
10
40A
240V
0.21%
D
(2)#8 CU, (1)#8 N, (1)#10 EGC, THWN-2, 0.75"EMT(min)
10
40A
240V
0.21%
General Notes:
O
THIS DRAWING CONSTITUTES THE
CONFIDENTIAL INFORMATION OF A&R SOLAR
AND ITS RECEPTOR. POSSESSION DOES NOT
CONFER ANY RIGHT IN OR LICENSE TO USE IT
OR THE INFORMATION DISCLOSED HEREIN
NOR ANY RIGHT TO REPRODUCE THIS
DRAWING OR ANY PART HEREIN WITHOUT
THE WRITTEN CONSENT OF A&R SOLAR.
O¢
O
COrqU)CO
�_
cn N
(L)
O
C M
ol�
E06<
3:
o N
=
U
0� N
a-
ru O
N
p
.O
i_I N
"D
E
o
-a
L.
O
W
IL
REVISIONS
Rev. #: I Date:
Utility: Snohomish PUD IDesigned by: Thomas N
1. EGC Where exposed to physical damage will be #6AWG Project Manager:
Bare CU Arthur Eith
2. If installing conduit on the roof, maintain greater than 7/8" (612) 298-1795
above the surface
3. NEC 690.12: Rapid Shutdown initiated by loss of Grid or AC Current Date:3ul 07, 2022
Disconnect
4. For supply side taps, a #6 GEC (min.) will be run separately
from the disconnect and connected to the grounding electrode E1 Single Line
with an irreversible crimp
PV Electrical Calculations
Inverter Specs
Watts
Output
AC
Voltage
# of
Inverters
OCPD
Total AC
Comb.
EGC
AC
W
(A)
out.(A)
OCPD
Solar Edge SE7600H
7600
32.00
240
1
40
32.0
40
#10
f
Ampe
****N/A****
0
0.00
0
0
0
****N/A****
0
0.00
0
0
0
Module Specs
Wats
Imp
Vmp
Voc
Isc
Temp. Coef V(oc)
pC
Volt
Solaria 40OR-PM
400
9.41
42.4
51.1
9.82
-0.29
#10
Max V(
Max
Temp. Adjusted
7136.8
55.8
Optimizer?
S440 SolarEdge Optimizer
Max current output: 15A, Max Voltage: 480V
Equipment
Solar Edge SE7600H
****N/A****
****N/A****
Mppt Input
1
1 2
1 3
1
1 2
1 3
1
1 2
3
Module
Solaria 40OR-PM
****SELECT****
****SELECT****
# Modules per String
13
12
0
0
0
0
0
0
0
# Strings
1
1
0
0
0
0
0
0
0
# of Mods per group
13
12
0
0
0
0
0
0
0
# of Mods/inverter
25
0
0
# of Inverters
1
0
0
Total # of Modules
25
Ref.
Conductor Description
Distance
AL CU
ft
A
String to Jbox
50
Cu
B
Jbox to Inverter
50
Cu
C
Inverter to Disconnect
10
Cu
D
Disco. to Interconnect
10
Cu
E
F
G
H
Array Specs (Adjusted for Temperature)
Inverter
Solar
EdgeSE7600H
****N/A****
****N/A****
ilppt Input
1
2
3
1
2
3
1
2
3
-age (Imp)
13.00
12.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
�11 1 �11 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
iltage(DC) 480.0 480.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
kmps (DC) 15.00 15.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Max Array Power(STC): 10 kW DC
Max Continuous AC Power: 7.6kW AC
Interconnection Calcs
Main Breaker
200
Bus Bar
200
Max PV OCD AI lowed
40
PV OCPD Device Used
40
Tap or Breaker?
Breaker
Site Conditions
ASHRAE Site:
Seattle
Low Temp (°F)
19
High 2%Temp (°F)
84
High 0.4%Temp (°F)
91
Wire
Gauge
(QTY) Phase
Neutral
Neutral
EGC
(AWG)
Wire Type
Conduit
Min.
Conduit
90°C
Rating
Temp
Correct.
Fill
Derate
Derated
75°C
Rating
Current
Operating
Voltage
Conductors
AWG
(QTY)
Type
Ampacity
@125%
Voltage
Drop
#10
2
N/A
N/A
#6
PV Wire 600V
AIR
N/A
40
1
100%
40.00
35
18.8
400
0.40%
#10
4
N/A
N/A
#10
THWN-2
EMT
0.751I
40
1
80%
32.00
35
18.8
400
0.40%
#8
2
#8
1
#10
THWN-2
EMT
0.751'
55
1
100%
55.00
50
40.0
240
0.21%
#8
2
#8
1
#10
THWN-2
EMT
0.75"
55
1
100%
55.00
50
40.0
240
0.21%
A&RSOLAR
3211 Martin Luther King Jr Way S.
Seattle, WA 98144 (206)707-9937
THIS DRAWING CONSTITUTES THE
CONFIDENTIAL INFORMATION OF A&R SOLAR
AND ITS RECEPTOR. POSSESSION DOES NOT
CONFER ANY RIGHT IN OR LICENSE TO USE IT
OR THE INFORMATION DISCLOSED HEREIN
NOR ANY RIGHT TO REPRODUCE THIS
DRAWING OR ANY PART HEREIN WITHOUT
THE WRITTEN CONSENT OF A&R SOLAR.
QO
z
o��00
l0
cnN
C
I
00
O�
<<
U
N
N
,-.
=
4-1
N
70
V
O
o
ru
O
N
p
E
-O
L
a�
O
LV
REVISIONS
Rev. #: I Date:
Designed by: Thomas N
Project Manager:
Total Voltage Drop: 1.22% Arthur Eith
(612) 298-1795
Current Date:Jul 07, 2022
E2 Electrical
Calculations
Typical Placards
A) NEC 2020 690.13 & 691.15
B) NEC 2020 705.12 (13)(3)(2)
C) Utility Requirement
D) Utility Requirement (Commercial Only)
D) A&R Solar Requirement (Residential
Customer -Owned)
E) A&R Solar Requirement * if combiner used
F) NEC 2020 690.13 (B)
I) NEC 2020 690.31 (D)(2)
K) NEC 2020 690.13 (B)
SOLAR PV SYSTEM EQUIPPED
WITH RAPID SHUTDOWN
TURN RAPID SHUTDOWN
SWITCH TO THE
"OFF" POSITION TO
SOLARAELS
PV PANELS
SHUTDOWN PV SYSTEM
AND REDUCE
SHOCK HAZARD IN THE
ARRAY
L) NEC 2020 690.56 (C)
*Used with Micro Inverters or DC Optimizers
O) A&R Solar Requirement * if
multiple inverters
IAWARNING DUAL POWER SOURCE]
SECOND SOURCE IS PHOTOVOLTAIC SYSTEM
P) NEC 2020 705.12(C) & 690.59
R) AHJ Requirement * if combiner used
S) NEC 2020 230.85(1)
T) NEC 2020 230.85(3)
Custom Placards &*1.PA�
A&RSOLAR
3211 Martin Luther King Jr Way S.
PLACARD S , _ C S U.T ` Seattle, WA 98144 (206)707-9937
NEC 690.54
AX Letter Height: 1/8"
. Inverter Backfeed
Maintain 1/4" border 1
Breaker
Red / White
NEC 690.53
NEC 690.54
Letter Height: 1/8"
THIS DRAWING CONSTITUTES THE
CONFIDENTIAL INFORMATION OF A&R SOLAR
Maintain 1/4" border 1 Solar Edge SE76WH
AND RECEPTOR.NOT
CONF RSANY RIGHT INOSSESSION OR LICENSE TOE USE T
OR THE INFORMATION DISCLOSED HEREIN
Red / White
NOR ANY RIGHT TO REPRODUCE THIS
DRAWING OR ANY PART HEREIN WITHOUT
THE WRITTEN CONSENT OF A&R SOLAR.
Letter Height: 1/8" (1) for each
Maintain 1/4" border 1 Disconnect or upstream
Red / White loadcenters.
CAUTION:
POWER TO THIS SERVICE IS ALSO SUPPLIED FROM SOLAR PV SOURCES
WITH DISCONNECTS LOCATED AS SHOWN:
METER FOR MAIN HOUSE (NO SOLAR)
Site Directory Placard Quantity: 2
)LAR AC
CONNECT
NET METER
N
O
N
C 00 O
O M (f) 00
cnN Q)a)
C M
-� a
oO
_r N 3:
N n
N
C l0 N _0
ru O N p
o N `° E
W
REVISIONS
Rev. #: I Date:
Designed by: Thomas N
Project Manager:
Arthur Eith
(612) 298-1795
Current Date:Jul 07, 2022
G4 Placards
J) NEC 2020 690.56 (C)(2)
Category Equipment QTY Notes
Solar Equipment
Modules Solaria 40OR-PM 25
Optimizers S440SolarEdge Optimizer 25
Inverters Solar Edge SE7600H 1
Monitoring SolarEdge Integrated (inverter) Monitoring 1
Electrical Equipment
Disconnect 60A 600V 2 Pole ( Heavy Duty, No Fuse, Lockable
MeterBase MeterBase-125A 4 Jaw w/ 3.5" AWCAP
Meter Landis Gyr EA 110000-OP 29 240V
Solar Racking
Iron Ridge Racking BOM
Description
XR100 BIack,17'
XR100 BIack,14'
Kit, XR100 Bonded Splice BOSS
Universal Module Clamp, Black
Stopper Sleeve 40mm
Grounding Lug, Low Profile
Square -Bolt Bonding Attachment Hardware
1/4 x 3/4 Microinverter Bonding Hardware, T-Bolt
End Caps, 10 sets(package) XR100
U-Anchor 2400, Mill (Spacing: 48")
Fastener: #14 x 2-8" DF-#14 PH3 (8 /mount)
L-Feet, Black
System Weights
Racking Weight(lbs)
Total Weight(lbs)
Weight/Attachme nt(lbs)
DeadLoad(PSF)
QTY
1 DH262URK
1
1
0
17
8
62
24
6
68
25
2
68
544
68
266
1416
20.8
2.66
&xl�I�i
A&RSOLAR
3211 Martin Luther King Jr Way S.
Seattle, WA 98144 (206)707-9937
THIS DRAWING CONSTITUTES THE
CONFIDENTIAL INFORMATION OF A&R SOLAR
AND ITS RECEPTOR. POSSESSION DOES NOT
CONFER ANY RIGHT IN OR LICENSE TO USE IT
OR THE INFORMATION DISCLOSED HEREIN
NOR ANY RIGHT TO REPRODUCE THIS
DRAWING OR ANY PART HEREIN WITHOUT
THE WRITTEN CONSENT OF A&R SOLAR.
O¢
O
_
0rqU)000
0
cn
N
(L)
M
o�
CM
E06<
o
3:
U
0�
N
=
No
0
N
4-1
•
N
�-.
_0
ru
O
N
p
.O
Ea
o
-
L
0
W
IL
REVISIONS
Rev. #: I Date:
Designed by: Thomas N
Project Manager:
Arthur Eith
(612)298-1795
Current Date:3ul 07. 2022
G5 Equipment
BOM