Loading...
REVIEWED BLD PLN BLD2022-0705+Manufacturer_Specifications_and_Installation_Instructions+5.27.2022_12.37.50_PM+2898614Job Name: T-Mobile Woodway, Edmonds, WA. System Reference: FC-1/CU-1 Date: 5-27-22 Indoor Unit .......................... Outdoor Unit Standard Model ............... ° Seacoast Model ............... III I rx� III III1--—--—--—---- Reviewed by ' City of Edmonds II Planning Division — 1 II I t� INDOOR UNIT FEATURES • Sleek, compact design • Simple installation • Vane setting for air flow direction control • Auto fan speed mode • Ideal for spaces such as server rooms, daycare centers, classrooms, churches, small offices, and more • Multiple control options available: o kumo cloud® smart device app for remote access o Third -party interface options o Wired or wireless controllers OUTDOOR UNIT FEATURES • Variable speed INVERTER -driven compressor • Power receiver pre -charged with refrigerant volume for piping length up to 100 ft • Low ambient cooling down to -40°F providing 100% capacity (with wind baffles) • 24-hour continuous operation (cooling mode) • High pressure protection • Fast restart • Superior energy and operational efficiency PKA-A36KA7 ..... PUY-A36NKA7 PUY-A36NKA7-BS RECEIVED May 27 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT BLD2022-0705 REVIEWED BY CITY OF EDMONDS Specifications are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Cooling at 95°F' Maximum Capacity Rated Capacity Minimum Capacity Maximum Power Input BTU/H 36,000 BTU/H 36,000 BTU/H 16,000 W 3,330 Rated Power Input W 3,330 Moisture Removal Pints/h 9.7 Sensible Heat Factor 0.70 Power Factor % 96.5/96.5 Efficiency SEER 18.8 EER' 10.8 ENERGY STAR® Certified No Electrical Voltage, Phase, Frequency 208/230, 1, 60 Guaranteed Voltage Range VAC 198 - 253 Voltage: Indoor - Outdoor, S1-S2 VAC 208/230 Voltage: Indoor - Outdoor, S2-S3 V DC 24 Short-circuit Current Rating [SCCR] kA 5 Recommended Fuse/Breaker Size (Oudoor) A 30 Recommended Wire Size [Indoor - Outdoor] AWG 14 Power Supply Indoor unit is powered by the outdoor unit Indoor Unit MCA A 1.0 Fan Motor Full Load Amperage A 0.57 Fan Motor Output W 56 Fan Motor Type DC Motor Airflow Rate at Cooling, Dry CFM 705-810-920 Airflow Rate at Cooling, Wet CFM 635-730-830 Sound Pressure Level [Cooling] dB[A] 43-46-49 Drain Pipe Size In. [mm] 5/8 [16] Coating on Heat Exchanger — Extemal Finish Color White Munsell 1.OY 9.2/0.2 Unit Dimensions W x D x H: In. [mm] 46-1/16 x 11-5/8 x 14-3/8 [1170 x 295 x 365] Package Dimensions W x D x H: In. [mm] 51 x 14-1/4 x 18-1/2 [1295 x 362 x 470] Unit Weight Lbs. [kg] 46 [21] Package Weight Lbs. [kg] 53 [24] Indoor Unit Operating Temperature Range Cooling Intake Air Temp [Maximum / Minimum]* °F 90 DB, 72 WB / 66 DB, 61 WB Heating Intake Air Temp [Maximum / Minimum] °F 77 DB / 59 DB Outdoor Unit MCA A 25.0 MOCP A 31 Fan Motor Full Load Amperage A 0.5 + 0.5 Fan Motor Output W 74 Airflow Rate CFM 3880 Refrigerant Control LEV Defrost Method Reverse Cycle Coating on Heat Exchanger Blue Fin Coating (BS Model only) Sound Pressure Level, Cooling' dB(A) 52 Compressor Type INVERTER -driven twin rotary Compressor Model MNB33FBRMC-L Compressor Rated Load Amps A 8 Compressor Locked Rotor Amps A 13.0 Compressor Oil Type H Charge oz. FV50S H 45 External Finish Color Ivory Munsell 3Y 7.8/1.1 Base Pan Heater N/A Unit Dimensions W x D x H: In. [mm] 41-5/16 x 13 (+1-3/16) x 52-11/16 [1050 x 330 (+30) x 1338] Package Dimensions W x D x H: In. [mm] 42-15/16 x 17-11116 x 56-4/16 [1091 x 450 x 1429] Unit Weight Lbs. [kg] 211 [96] Package Weight Lbs. [kg] 243 [110] Outdoor Unit Operating Temperature Range Cooling Air Temp [Maximum / Minimum]* °F 115 DB 140 DB Refrigerant Type R410A Charge Lbs, oz 10, 6.0 Chargeless Piping Length Ft. [m] 0.0 [30.0] Additional Refrigerant Charge Per Additional Piping Length oz./Ft. [g/m] 0.3 [22.5] NOTES: AHRI Rated Conditions (Rated data is determined at a fixed compressor speed) 'Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB *Outdoor Unit Operating Temperature Range (Cooling Air Temp (Maximum / Minimum)): • Wind baffles required to operate below 23°F DB in cooling mode. Cooling -only system with advanced wind baffle: -40°F - 115°F. Refer to wind baffle documentation for further information. **Outdoor Unit Operating Temperature Range (Cooling Thermal Lock -out / Re -start Temperatures; Heating Thermal Lock -out / Re -start Temperatures): • System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures. SEACOAST PROTECTION (-BS MODELS) External Outer Panel: Phosphate coating +Acrylic -Enamel coating Fan Motor Support: Epoxy resin coating (at edge face) • Separator Assembly Valve Bed: Epoxy resin coating (at edge face) • Blue Fin treatment is an anti -corrosion treatment that is applied to the condenser coil to protect it against airborne contaminants. Specifications are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Gas Pipe Size O.D. [Flared] In.[mm] 5/8 [15.88] Liquid Pipe Size O.D. [Flared] In.[mm] 3/8 [9.52] Piping Maximum Piping Length Ft. [m] 225 [68] Maximum Height Difference Ft. [m] 100 [30] Maximum Number of Bends 15 NOTES: AHRI Rated Conditions (Rated data is determined at a fixed compressor speed) 'Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB *Outdoor Unit Operating Temperature Range (Cooling Air Temp (Maximum / Minimum)): • Wind baffles required to operate below 23*F DB in cooling mode. Cooling -only system with advanced wind baffle: -40°F - 115°F. Refer to wind baffle documentation for further information. **Outdoor Unit Operating Temperature Range (Cooling Thermal Lock -out / Re -start Temperatures; Heating Thermal Lock -out / Re -start Temperatures): • System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures. SEACOAST PROTECTION (-BS MODELS) External Outer Panel: Phosphate coating +Acrylic -Enamel coating Fan Motor Support: Epoxy resin coating (at edge face) Separator Assembly Valve Bed: Epoxy resin coating (at edge face) • Blue Fin treatment is an anti -corrosion treatment that is applied to the condenser coil to protect it against airborne contaminants. Specifications are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. 3-Pin Connector BACnet® and Modbue Interface ❑ PAC-715AD ❑ PAC-UKPRC001-CN-1 IT Extender ❑ PAC-WHS011E-E Control Interface kumo station® for kumo cloud® Lockdown bracket for remote controller Thermostat Interface USNAP Adapter Wireless Interface for kumo cloud® ❑ PAC-WHS01 HC-E ❑ RCMKPICB ❑ PAC-US444CN-1 ❑ PAC-WHS01UP-E ❑ PAC-USWHS002-WF-2 Flush Mount Temperature Sensor ❑ PAC-USSEN001-FM-1 Remote Sensor Remote Temperature Sensor ❑ PAC-SE41 TS-E Wireless temperature and humitity sensor for kumo cloud® ❑ PAC-USWHS003-TH-1 Deluxe Wired MA Remote Controllert ❑ PAR40MAAU Wired Remote Controller Simple MA Remote Controllert ❑ PAC-YT53CRAU-J Touch MA Controllert ❑ PAR-CT01 MAU-SB kumo touch' RedLINK'° Wireless Controller ❑ MHK2 Wireless Remote Controller Wireless MA Controller ❑ PAR-FA32MA-W Wireless MA Remote Controller ❑ PAR-FL32MA-E Blue Diamond (Advanced) Mini Condensate Pump w/ Reservoir & Sensor (208/230V) [recommended] ❑ X87-721 Blue Diamond (MegaBlue Advanced) Condensate Pump w/ Reservoir & Sensor ❑ X87-835 Condensate Blue Diamond Sensor Extension Cable —15 Ft. ❑ C13-103 Drain Pan Level Sensor/Control ❑ SS610E Sauermann Condensate Pump ❑ S130-230 (30A/600V/UL) [fits 2" X 4" utility box] - Black ❑ TAZ-MS303 Disconnect Switch (30A/600V/UL) [fits 2" X 4" utility box] - White ❑ TAZ-MS303W 10' x 3/8" x 10' x 5/8" Lineset (Twin -Tube Insulation)tt ❑ MPLS385812T-10 100' x 3/8" x 100' x 5/8" Lineset (Twin -Tube Insulation)tt ❑ MPLS385812T-100 15' x 3/8" x 15' x 5/8" Lineset (Twin -Tube Insulation)tt ❑ MPLS385812T-15 Lineset 30' x 3/8" x 30' x 5/8" Lineset (Twin -Tube Insulation)tt ❑ MPLS385812T-30 50' x 3/8" x 50' x 5/8" Lineset (Twin -Tube Insulation)tt ❑ MPLS385812T-50 65' x 3/8" x 65' x 5/8" Lineset (Twin -Tube Insulation)tt ❑ MPLS385812T-65 Specifications are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Air Outlet Guide Air Outlet Guide (1 Piece) Control/Service Tool ❑ PAC-SH96SG-E (two pieces are required) ❑ PAC-SK52ST Control/Service Tool M- & P-Series Maintenance Tool Cable Set ❑ M21 EC0397 USB/UART Conversion Cable (Required for all laptop connection) ❑ M21 EC1397 Distribution pipe Twinning Distribution Pipe (50:50)ff ❑ MSDD-50TR-E Drain Socket Drain Socket ❑ PAC-SG61 DS-E M-NET Converter ❑ PAC-SJ85MA-E M-NET Converter M-NET Converter ❑ PAC-SJ95MA-E 14 Gauge, 4 wire MiniSplit Cable-250 ft. roll ❑ S144-250 14 Gauge, 4 wire MiniSplit Cable-50 ft. roll ❑ S144-50 Mini -Split Wire 16 Gauge, 4 wire MiniSplit Cable-250 ft. roll ❑ S164-250 16 Gauge, 4 wire MiniSplit Cable-50 ft. roll ❑ S164-50 Mounting Pad Condensing Unit Mounting Pad: 24" x 42" x 3" ❑ ULTRILITE2 18" Dual Fan Stand ❑ QSMS1802M 24" Dual Fan Stand ❑ QSMS2402M Stand Condenser Wall Bracket ❑ QSWB2000M-1 Condenser Wall Bracket -Stainless Steel Finish ❑ QSWBSS Outdoor Unit Stand —12" High ❑ QSMS1202M Front Wind Baffle ❑ WB-PA3 (two pieces are required) Wind Baffle Rear Wind Baffle ❑ WB-RE6 Side Advanced Wind Baffle ❑ WB-SD6 Specifications are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. LA.ide Itnadwul bde kH plpirg 2-29/3 A 1-3/16 30 7-3I8 35 2-19/32 66 L16-11/16(423.7 Top side 17(431.7) LE underside n \T� Piping connection '1' Vane(auto) Louver manual s s Knockout hole for leaver piping Sleeve (purchased locally) Through hole [ 2-15/16 [ 2-15/16-[ 3-5/32 ([ 75) ([ 75-[ 80) Required space(Indoor unit) Air inlet 777/ S Air outlet � Min.8-21/32(220) Min.3-31132(100.5) Mint-1116(52.3) d, Canter measurement hole [ a/32r 2.5) w 4[ 11Po2([9)Boll bole gg Mount boaN S[3116([5.1) Knonkop'ulSM1ole br yyell 3 Unit: inch (mm) Right side 1 Liquid pipe R Knockout hole for piping C m` B 12 2-9/1865 13/32(10.7) 3-1132(77) 3-7116(87) 2-911665 i �nl+�sj 0 121125) &32(37.5) P-15g2162.5) 711o7 ) 4-1IB((1295.: SJg2(129.51 65116(167) 1217) s-+13z(221,11 aezl 6 ) 1112(2e2) 5ez(3os.5) 12-11A(311) Specifications are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Unit: mm<in> 1 FREE SPACE (Around t 13 FOUNDATION B 14 PIPING -WIRING DIRECTIONS The diagram below shows a basic example. Explantion of particular details are Dimensions of space needed for service access are Please secure the unit firmly with 4 foundation (Mig<W318>) bolts. Piping and wiring connections can be made from 4 directions: given in the installation manuals etc. shown in the below diagram. (Bolts and washers must be FRONT, Right, Rear and Below. »` purchased locally.) <Foundation bolt heighb �m� 0 FOUNDATION j �A° Nn. Mln s& Example of Notes �1D Refingerant GAS pipe connecdan(FLARE) e15.88(518F) L`l Rehig—t LIQUID pipe conneetion(FLARE) 09.52(318F Y - Indication of STOP VALVE connection xatbn. Piping Knockout Hole Details I lmws LIL 7i1��1�� Y01=1�i� e-_ • ��� r FORM# PKA-A36KA7 & PUY-A36NKA7(-BS) - 202108 1340 Satellite Boulevard Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvae.com ONDB Intertek Specifications are subject to change without notice. © 2021 Mitsubishi Electric Tirane HVAC US LLC. All rights reserved.