Loading...
APPROVED BLD-RESUB 1-Architectural_Plan+6.15.2021_2.24.43_PM+2251368PROPERTY INFORMATION: ASSESSOR PARCEL #: 00513100013803 ZONE: RS-12 LEGAL DESCRIPTION: MEADOWDALE BEACH BILK 000 D-03 LOT 1 OF CITY ED SP NO S-6-79 REC AF NO 7905090293 LOT # TBD LOT SQUARE FOOTAGE: PROPERTY ADDRESS: OWNER: OWNER ADDRESS: OWNER / APPLICANT PHONE NUMBER: OWNER / APPLICANT EMAIL ADDRESS: GOVERNING CODE: EXISTING PROPERTY DESCRIP.: SCOPE OF WORK: 39 Acres (16,988 SF) 17303 72nd Ave. W. Edmonds, WA 98206 Mark and Erin Gross Same as property address 206.949.8222 erin.danae.gross@gmail.com 2018 IRC, 2018 WSEC Per County Assessor Interior remodel and window replacement GROSS RESIDENCE REMODEL 17303 72nd Ave W - Edmonds, WA 98026 GENERAL PROJECT NOTES: ALL WORK SHALL CONFORM TO APPLICABLE CODES, INCLUDING BUT NOT LIMITED TO THE IBC 2018 EDITION WITH WASHINGTON STATE AMENDMENTS, INTERNATIONAL RESIDENTIAL CODE, INTERNATIONAL MECHANICAL CODE, 2018 UNIFORM PLUMBING CODE, 2018 NEC AND ALL RULES, REGULATIONS AND ORDINANCES OF THE GOVERNING AUTHORITY. THE GENERAL CONTRACTOR SHALL VERIFY ALL DIMENSIONS, AND SITE CONDITIONS, AND SHALL NOTIFY THE OWNER IMMEDIATELY OF ANY DISCREPANCIES, ERRORS OR OMISSIONS PRIOR TO PROCEEDING WITH THE WORK. DO NOT SCALE THE DRAWINGS FOR CRITICAL DIMENSIONS. DIMENSIONS ARE SHOWN TO THE FACE OF STUD UNLESS NOTED OTHERWISE. THE PROJECT SCHEDULE SHALL BE COORDINATED WITH THE OWNER TO ENSURE PROPER ACCESS TOTHE PROJECT SITE AND IDENTIFY ANY DAYS THE SITE WOULD BE MADE UNAVIABLE TO THE CONTRACTOR. HOURS OF CONSTRUCTION SHALL BE LIMITED IN ACCORDANCE WITH THE LOCAL JURISDICTIONS NOISE ORDINANCE. PLUMBING, ELECTRICAL AND MECHANICAL CONTRACTORS SHALL VERIFY ALL REQUIREMENTS FOR THIS PROJECT AND COMPLY WITH ALL LOCAL CODES, SUBMIT PLANS FOR APPROVAL AND OBTAIN PERMITS BEFORE STARTING WORK. GENERAL CONTRACTOR SHALL REPAIR ANY DAMAGE CAUSED BY HIMSELF OR ANY SUB -CONTRACTORS. IF INSPECTIONS OF WORK ARE REQUIRED BY THE GOVERNING AUTHORITY, THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING INSPECTIONS WITH THE CITY. ENERGY CODE NOTES: 1. ENERGY CREDITS NOT REQUIRED FOR INTERIOR ONLY REMODEL 2. ALL REPLACED WINDOWS WILL MEET A U-FACTOR OF 0.30 OR BETTER 3. EXISTING CEILING, WALL OR FLOOR CAVITIES EXPOSED DURING CONSTRUCTION PROVIDED THAT THESE CAVITIES ARE FILLED WITH INSULATION. 2X4 FRAMED WALLS SHALL BE INSULATED TO A MINIMUM OF R-15 AND 2X6 FRAMED WALLS SHALL BE INSULATED TO A MINIMUM OF R-21. OBTAIN ELECTRICAL PERMIT FROM STATE LABOR & INDUSTRIES APPROVED PLANS MUST BE ON JOB SITE City of Edmonds Building Department APPROVED Plans ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE City Of Edmonds Building Department Work INTERIOR REMODEL Address 17303 72ND AVE W Owner GROSS --------------------------------- Approved Date � _ _0_ _6_ _/28/2021 --- ---9/00__4 Building Official et"'/f� QiGW Permit Number BLD2021-0675 --------------------- SHEET INDEX GENERAL G-001 COVER SHEET AND PROJECT DATA DEMOLITION D-101 1 STAND 2ND FLOOR DEMO PLAN VICINITY MAP ARCHITECTURAL A-101 FIRST FLOOR PLAN A-121 SECOND FLOOR PLAN A-131 REFLECTED CEILING PLANS A-141 ROOF PLAN A-201 EXTERIOR ELEVATIONS A-202 EXTERIOR ELEVATIONS A-301 DOOR SCHEDULE AND DETAILS w 0 0 w w U z w 0 Cn w U) O ry CD Comments: RESUB Jun 15 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT U 0 E w a� > Q N ti O co ti Ir— Drawing Title: COVER SHEET AND PROJECT DATA Date 05/14/2021 Drawn by: REV: Scale: As Shown Sheet Number: G-001 PERMIT SET EA OEB EB.2 OEC EB EB.2 EC I I I I DEMO EXISTING STAIR - IIIIIIII III IIIIII DEMO EXISTING STAIR DEMO PORTION OF EXISTING FLOOR7j= L 7/ EXIST MUDROOM DEMO INTERIOR WALLS & FIXTURES EXISTING WINDOW TO REMAIN \� \ DEMO EXISTING WINDOW EXIST BEDROOM N CD E2 - - - - - - - E2 - - - -VA- - � rn 0 00 EXIST BATHROOM INTERIOR GARAGE WALLS TO REMAIN O EXIST BEDROOM I w 17 EXIST DINING ROOM I I I U EXIST KITCHEN LU O U E I I z LU DEMO ALL INTERIOR WALLS C/1 N EXIST GARAGE Uj�Ny � — — EXISTING BRICK L.I. FIREPLACE AND CHIMNEY ��^^ DEMO INTERIOR TO BE DEMOLISHED vJ WALLS &FIXTURES PATCH AND REPLACE ROOF / I p N EXIST BEDROOM EXIST LIVING ROOM EXIST FAMILY ROOM C� III CD O EXIST BEDROOM EXIST BEDROOM I �I Co DEMO EXISTING WINDOW i GAS METER TO REMAIN I I I DEMO ALL EXTERIOR WINDOWS AT LEVEL 1 EXISTING ELEC. METER DEMO WINDOW AND PANEL TO REMAIN FIRST FLOOR DEMOLITION PLAN N SECOND FLOOR DEMOLITION PLAN N SCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0" RESUB Jun 15 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT DEMOLITION NOTES: Comments: 1. EXISTING ROOF STRUCTURE IS MANUFACTURED ROOF TRUSSES DESIGNED FOR 25' SPAN (REMAINING UNCHANGED). 2. NO INTERIOR WALLS HAVE BEEN DETERMINED TO BE LOAD BEARING. 3. NO REMOVAL OF LATERAL BRACING SHALL OCCUR. Drawing Title: 1ST AND 2 N D FLOOR DEMO PLAN Date 05/14/2021 Drawn by: CKW REV: No. Description Date Scale: AS Shown Sheet Number: D-101 PERMIT SET EA 2 A-2o2 OEB E B. 2 72' - 5" \� EC GENERAL FLOOR PLAN NOTES: 1. WINDOW SIZES & ROUGH OPENINGS TO BE VERIFIED BY CONTRACTOR. 2. FIREBLOCK ALL PLUMBING PENETRATIONS PER IRC SEC. 302.11. 3. ALL WOOD IN CONTACT WITH CONCRETE TO BE PRESSURE TREATED. 4. FURNITURE IS SHOWN DASHED FOR REFERENCE PROVIDED BY OWNER AND NOT PART OF CONTRACTOR RESPONSIBILITY. 5. FINAL LOCATIONS OF ELECTRICAL TO BE COORDINATED WITH OWNER 6. CLOSET SYSTEM TO BE DETERMINED BY OWNER, PROVIDE BLOCKING AS REQ'D. 7. COUNTER, PLUMBING FIXTURES AND MIRROR TO BE DETERMINED BY OWNER 8. KITCHENS, BATHROOMS, LAUNDRY ROOMS MUST BE VENTED MECHANICALLY PER SRC TABLE M1507.3. 9. FACTORY BUILT FIREPLACE TO BE LISTED, LABELED AND INSTALLED WITH THE CONDITIONS OF THE LISTING. FACTORY BUILT FIREPLACE MUST BE TESTED IN ACCORDANCE WITH UL127. FIREPLACE SELECTION TO MEET CRITERIA LISTED IN IRC100.4.1 10. SMOKE AND CO2 DETECTORS TO BE INSTALLED BY CONTRACTOR PER CURRENT CODE REGULATIONS 11. A MINIMUM OF 75 PERCENT OF PERMANENTLY INSTALLED LAMPS IN LIGHTING FIXTURES SHALL BE HIGH-EFFACACY LAMPS 12. ALL EXHAUST FANS SHALL VENT DIRECTLY TO THE EXTERIOR OF THE BUILDING PER M1501.1 AND M1506.2 13. CFM OF ALL EXHAUST FANS SERVING A SPACE 100 S.F. OR LESS TO BE A MIN. OF 50 CFM OR HIGHER. nnnR tinTPc- 1. MAXIMUM THRESHOLD HEIGHT TO BE 1/2". 2. DOOR GLAZING TO BE 3/4" DOUBLE INSULATED SEALED UNITS (SAFETY GLASS) WITH A U-FACTOR OF 0.30 3. TIGHT -FITTING SMOKE AND DRAFT CONTROL ASSEMBLY (20 MIN. RATING) 4. EXTERIOR DOOR SHALL BE HINGED AND SHALL BE SOLID CORE WOOD OR INSULATED STL. DOOR SHALL BE TIGHTLY FITTED AND WEATHERSTRIPPED. 5. THE PERIMETER OF DOOR FRAMES SHALL BE SEALED AIRTIGHT TO THE EXTERIOR. 6. GLASS IN DOOR SHALL BE SEALED IN A AIRTIGHT NON -HARDENING SEALANT. 7. MINIMUM 1/2" THROW ON DEAD BOLT OR DEAD LATCH FOR DOORS. 8. VISITOR OBSERVATION PORT FOR EXTERIOR DOORS. WINDOW NOTES: 1. WINDOWS WITHIN 10' OF GRADE OR ACCESSIBLE FROM DECK TO BE CAPABLE OF BEING LOCKED. 2. ALL GLAZING TO BE 1" INSULATED GLAZING UNIT WITH A U-VALUE OF 0.30 OR BETTER. FIREBLOCKING FIREBLOCKING SHALL BE PROVIDED IN WOOD -FRAMED CONSTRUCTION IN THE FOLLOWING LOCATIONS: 1. IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING FURRED SPACES AND PARALLEL ROWS OF STUDS OR STAGGERED STUDS, AS FOLLOWS: A. VERTICALLY AT THE CEILING AND FLOOR LEVELS. B. HORIZONTALLY AT INTERVALS NOT EXCEEDING 10 FEET (3048 mm). 2. AT INTERCONNECTIONS BETWEEN CONCEALED VERTICAL AND HORIZONTAL SPACES SUCH AS OCCURS AT SOFFITS, DROP CEILINGS, AND COVE CEILINGS. 3. IN CONCEALED SPACES BETWEEN STAIR STRINGERS AT THE TOP AND BOTTOM OF THE RUN. ENCLOSED SPACES UNDER STAIRS SHALL COMPLY WITH SECTION R302.7. 4. AT OPENINGS AROUND VENTS, PIPES, DUCTS, CABLES AND WIRES AT CEILING AND FLOOR LEVEL, WITH AN APPROVED MATERIAL TO RESIST THE FREE PASSAGE OF FLAME AND PRODUCTS OF COMBUSTION. THE MATERIAL FILLING THIS ANNULAR SPACE SHALL NOT BE REQUIRED TO MEET THE ASTM E 136 REQUIREMENTS. 5. FOR THE FIREBLOCKING OF CHIMNEYS AND FIREPLACES, SEE SECTION R1003.19. 6. FIREBLOCKING OF CORNICES OF A TWO-FAMILY DWELLING IS REQUIRED AT THE LINE OF DWELLING UNIT SEPARATION. E3 E2 FIRST FLOOR PLAN SCALE: 1/4" = V-0" 1/2" GWB, PAINT CO,L-QR PFR-40WI KRAFTFACED R-15 BATT INSLUATION A A 2x4 (DF STUD GRADE) - WOOD STUDS @ 16" O.C. 1/2" CDX PLYWOOD EXTERIOR SHEATHING EXTERIOR BUILDING WRAP LAP SIDING PER OWNER PRIME AND PAINT. COLOR PER OWNER TYPICAL EXTERIOR WALL .0 50'-5" 3'-9" 18'-3" '2" GWB, P T OLOR P R <4 ( BADE) S@16"O.0 LYWOOD IOR SHEATHING KTERIOR BUILDING RAP kP SIDING PER OWNER RIME AND PAINT. DLOR PER OWNER EXTERIOR GARAGE WALL 1/2" GWB, P BOTH SIDES COLOR P ER SOU UATING BA ATION A STUD CAVITY VIDE BLOCKING AS RUIRED AT WASHROOM AND CLOSET LOCATIONS 2x6 WOOD STUDS @ 16" O.C. INTERIOR 2X6 PARTITION 1/2" GWB, PAINT BOTH SIDES COLOR PER OWNER SOUND ATTENUATING BATT INSLUATION AT EACH STUD CAVITY PROVIDE BLOCKING AS REQUIRED AT WASHROOM AND CLOSET LOCATIONS 2x4 WOOD STUDS @ 16" O.C. INTERIOR 2X4 PARTITION Uj U z Uj 0 �.Uj U) U) ONN V rA 0 E Uj Q co 0 co RESUB Jun 15 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Comments: Drawing Title: FIRST FLOOR PLAN Date 05/14/2021 Drawn by: CKW REV: I� No. Description Date �I 1 1 Permit Corrections 1 06/14/21 Scale: AS Shown Sheet Number: WALL TYPES LEGEND SCALE: 1" = V-0" A-101 PERMIT SET A-2o2 OEB EB.2 OEC E2 - SECOND FLOOR PLAN SCALE: 1/4" = 1'-0" 6'-9112" 13'-10" I I I - I I I I W T4 I iv I BEDROOM 60 o I I I <WT>4 8 -2 I DN 3' - 2 1 /2" 04 21 21 A N (V i I I 0o W T4 I DEN o N o I (o zo 00 '0 1 W T4 M A-202 I I I I co 23 22 22A iv 00 7 - 8' I ° W T477 I W T4 I N BATH 00 I o BEDROOM o 1 CC Eo I0 o I I I 5' - 6" EQ. 5' - 0" EQ. I I I I I I I I I I Comments: LU 0 0 2 W LU U Z LU 0 U) LU v ONN CD N 00 V! C 0 E 0 W Q N co 0 M r RESUB Jun 15 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT N Drawing Title: SECO ND FLOOR PLAN Date 05/14/2021 Drawn by: CKW REV: No. Description Date 1 1 Permit Corrections 1 1 06/14/21 Scale: AS Shown Sheet Number: A-121 PERMIT SET FIRST FLOOR REFLECTED CEILING PLAN SCALE: 1/4" = 1'-0" N + NOTE: -SMOKE AND CO2 DETECTORS TO BE INSTALLED AND FINAL LOCATIONS DETERMINED BY CONTRACTOR PER CURRENT CODE REGULATIONS ALL DEVICES SHALL BE INTERCONNECTED AND WHEN ONE DEVICE IS TRIGGERED ALL MUST ACTIVATE PER IRC R314.2.2 . - A MINIMUM OF 75 PERCENT OF PERMANENTLY INSTALLED LAMPS IN LIGHTING FIXTURES SHALL BE HIGH-EFFACACY LAMPS - ALL EXHAUST FANS SHALL VENT DIRECTLY TO THE EXTERIOR OF THE BUILDING PER M1501.1 AND M 1506.2 - CFM OF ALL EXHAUST FANS SERVING A SPACE 100 S.F. OR LESS TO BE A MIN. OF 50 CFM OR HIGHER. SMK SMOKE ALARM CO2 CO2 DETECTOR EXHAUST FAN OEB EB.2 OEC E3 E2 (El - J W 0 0 2 W W U Z W 0 Cn W Of C/) C) 0 noo CD RESUB Jun 15 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Comments: CD N O 00 Q vi 0 W Q ti 0 co ti Drawing Title: REFLECTED CEILING PLANS Date 05/14/2021 Drawn by: CKW REV: No. Description Date 1 Permit Corrections 1 06/14/21 Scale: AS Shown Sheet Number: SECOND FLOOR REFLECTED CEILING PLAN N A-131 SCALE: 1/4" = 1'-0" PERMIT SET E3 EA A-2o2 OEB EB.2 OEC y I I EXISTING DORMER TO REMAIN I I I EXISTING LEVEL 1 ROOF TO REMAIN --\ N 00 W o I I p Q 0 1 w W vi 0 z W U I X 1 z w III 4" / 1'-0" 4" / 1'-0" A-202 W 3 p A-201 EXISTING RIDGE U) W Q INFILL ROOF AT DEMOLISHED CHIMNEY. MATCH EXISTING ROOFING I vJ 0 0 N co co r ROOF PLAN SCALE: 1/4" = 1'-0" RESUB N Jun 15 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Comments: Drawing Title: ROOF PLAN Date 05/14/2021 Drawn by: CKW REV: No. Description Date Scale: AS Shown Sheet Number: A-141 PERMIT SET EA EB EB 2 EC --- -- -- -- ---41-011-Win--0" -----3'-0"— - 3'-0"— -- -- -- -- -- 0 0 ih ih M WEST ELEVATION SCALE: 1/4" = 1'-0" E3 NORTH ELEVATION SCALE: 1 /4" = 1'-0" UPPER ROOF 18' - 0 3/4" SECOND FLOOR 9' - 5 3/4" LOWER ROOF 8'-0" FIRST FLOOR GARAGE -1' - 0" UPPER ROOF 18'-03/4" SECOND FLOOR 9'-53/4" LOWER ROOF 8'-0" FIRST FLOOR — — — — nI nl GARAGE -1' - 0" Comments: Drawing Title: J LU 0 O 2 LU 0. W U Z W 0 U) LU O W CD N O 00 Q U C O E 0 W Q C CN 0 co r RESUB Jun 15 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT EXTERIOR ELEVATIONS Date 05/14/2021 Drawn by: CKW REV: No. Description Date Scale: AS Shown Sheet Number: A-201 PERMIT SET EAST ELEVATION SCALE: 1/4" = 1'-0" EC � EB.2 EB EA UPPEBR ROOF „ -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- _SECONDFLOORR -- -- -- -- -- -- -- -- -- -- — -- ----3'-0"--3'-0"-- -- - - 2 _6-2�-6"--- -- -- -- -- -- -- LOWER --800F' SOUTH ELEVATION SCALE: 1/4" = 1'-0" FIRST FLOOR GARAGE -- -- -- 1' 0�" E1 E2 E3 UPPER ROOF 18'-03/" _SECOND FLOOR 9'-53/4" _LOWER ROOF FIRST FLOOR -- -- n1 n� GARAGE -1' - 0" Comments: Drawing Title: LU 0 O 2 NW 0. W U Z W 0 U) W O W (N C) 00 C O E 0 W Q C ti co O co ti r RESUB Jun 15 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT EXTERIOR ELEVATIONS Date 05/14/2021 Drawn by: CKW REV: No. Description Date Scale: AS Sho Sheet Number: A-202 PERMIT SET 1. CUT MODIFIED ""' IN HOUSE WRAP 2. APPLY (zii I Pi ocNmir AND SEF ' SEALANT ALONG HEAD �! AND SIDES ONLY i PATCH CORNERS 3. INSTALL WINDOW AND 4. APPLY HEAD FLASHING 5. TAPE CUTS OVER SIDE FLASHING r HEAD FLASHING EXTEND UP 6" '; — PEEL & STICK FLASHING SE SF -- TURN UP 6" CUT AND FOLD PEEL AND STICK FLASHING BATT INSULATION PER WALL TYPE EXTERIOR BUILDING WRAP (2) 2X6 DF GRADE 2 FOR OPENINGS UP TO 6' WIDE ROOF LOAD ONLY. 4x8 DF GRADE 2 HEADER AT NEW WINDOW OPENINGS UP TO 10' WIDE LAP SIDING PER OWNER PRIME AND PAINT. COLOR PER OWNER 1x4 PAINTED WOOD TRIM EXTERIOR GRADE SEALANT AT ALL JOINTS EXTERIOR WINDOW OR DOOR OPENING 5 TYPICAL OPENING HEADER AT EXTERIOR WALL SCALE: 1 1/2" = V-0" i i i 4 TYPICAL WINDOW FLASHING SEQUENCE DETAIL SCALE: 1 1/2" = V-0" / i i i 3 STAIR AND RAILING DETAIL SCALE: 1" = V-0" PER PLAN DOOR SCHEDULE Door Frame Details Comments Door Number Width Height Thickness Door Material Frame Head Jamb Sill 01 3' - 0" 6' - 6" 1 3/8" 02 4' - 0" 6' - 8" 1 3/8" 03 6' - 0" 6' - 8" 2" 03A 4' - 0" 6' - 8" 1 3/8" 04 2' - 6" 6' - 8" 1 3/8" 04A 2' - 6" 6' - 8" 1 3/8" 04B 2' - 6" 6' - 8" 1 3/8" 04C 2' - 6" 6' - 8" 1 3/8" 05 2' - 6" 6' - 8" 1 3/8" 06 6' - 0" 6' - 6" 2" 1 07 3' - 0" 6' - 6" 1 3/8" solid core door with self closing device 08 3' - 0" 6' - 6" 1 3/8" solid core door with self closing device 21 2' - 6" 6' - 8" 1 3/8" 21A 6'-0" 6'-8" 2" 22 2' - 6" 6' - 8" 1 3/8" 22A 6' - 0" 6' - 8" 2" 23 2'- 6" 6' - 8" 1 3/8" *SEE DOOR NOTES ON SHEET A-101. FINAL SIZES AND FINISHES TO BE DETERMINED BY OWNER. NOTE: GUARDRAIL DESIGN TO WITHSTAND 20OPSF FORCE BALUSTERS TO WITHSTAND 50PSF FORCE PAINTED MDF TRIM BOTH SIDES OF STAIRS STAIR TREAD AND NOSING PER OWNER STAIR RISER MATERIAL PER OWNER 1/2" GWB AT ALL EXPOSE OR USEABLE SPACE BELOW STAIRS 1 1/4" O.D. MIN. 1 1/2" CLEAR AT NOTES: GUARDS ON THE OPEN SIDES OF STAIRS SHALL NOT HAVE OPENINGS WHICH ALLOW PASSAGE OF A 4'' O SPHERE. OPEN RISERS ARE PERMITTED, PROVIDING THAT THE OPENINGS BETWEEN TREADS DOES NOT PERMIT THE PASSAGE OF A 4" O BALL. MINIMUM STAIR TREAD WIDTH OF A WINDER TO 6" AT THE NARROWEST POINT. RAILS TO CONFORM TO SRC R311.7.7 A34 FRAMING ANCHOR (1) LAYER 5/8" GWB BELOW STAIRS STRINGERS PER STRUCTURAL FIRE BLOCKING 4 MIN - SPAN & 4 WALL 2x4 THRUST BLOCK ALONG STRINGER BETWEEN STUDS AND AT TOP AND BOTTOM OF STAIRS, TYP. J LU 0 0 2 NW Q. LU U Z LU 0 � v ) LU Of VJJ V ) 0// L.L V RESUB Jun 15 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Comments: N O rn Q 0 W I 0 co r Drawing Title: D00 SCHEDULE AN DETAIL Drawn by: CKW REV: No. Description Date Permit Corrections 1 06/14/21 Scale: As Shown Sheet Number: A-301 PERMIT SET