Loading...
BLD2022-0988_Other_7.25.2022_1.46.33_PM_3010202F DA/K/N ■ Standard Features • Compatible with Daikin One+ smart thermostat and other Daikin communicating equipment • Heavy-duty stainless -steel dual -diameter, tubular heat exchanger • Two -stage gas valve provides quiet, economical heating • Durable Silicon Nitride igniter • Quiet two -speed draft inducer • Self -diagnostic control board with constant memory fault code history output to a dual 7-segment display • Color -coded low -voltage terminals with provisions for electronic air cleaner and humidifier • Efficient and quiet variable -speed airflow system gently ramps up or down according to heating or cooling demand • Multiple continuous fan speed options offer quiet air circulation • Auto -Comfort and enhanced dehumidification modes available • California Low NOx emissions -compliant models available • Can no longer be installed in California's South Coast Air Quality Management District (SCAQMD) on or after October 1, 2019 • AHRI Certified; ETL Listed DMSOVC / DC80VC TWO -STAGE, VARIABLE SPEED ECM GAS FURNACE 80%AFUE HEATING INPUT60, 000 —100, 000 BTU/H ■ Contents Nomenclature.............................................2 Product Specifications................................3 Dimensions.................................................5 Airflow Data................................................7 Wiring Diagram........................................14 Accessories...............................................15 ■ Cabinet Features • Multi -position installation: DM80VC: Upflow, horizontal left or right. DC80VC: Downflow, horizontal left or right. Convenient left or right connection for gas and electrical service • Cabinet air leakage (QLeak) <_ 2% • Heavy -gauge steel cabinet with durable baked -enamel finish • Fully insulated heat exchanger and blower section LIFETIME 12YlI12YEAR HEAT UNITPARTS EXCHANGER DEDLACEME NLIMITED LIMITEDLIMITED WARRANTY WARRANTYWARRANTY AM k IWI IS09M1 I � I RTIEIED *Complete warranty details available from your local dealer or at www.daikincomfort.com. To receive the Lifetime Heat Exchanger Limited Warranty (good for as long as you own your home), the 12-Year Unit Replacement Limited Warranty and the 12-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Additional requirements for annual maintenance are required for the Unit Replacement Limited Warranty. Online registration and some of the additional requirements are not required in California or Quebec. SS-DM80VC www.daikincomfort.com 02/21 Supersedes 10/19 NOMENCLATURE D M 80 V C 060 3 B X 1 2 Brand D - Daikin Brand Configuration M - Upflow/Horizontal C - Downflow/Horizontal D - Dedicated Downflow AFUE 97 — 97-98% AFUE 92-92%AFUE 96-96%AFUE 80-80%AFUE Gas Valve 3,4 5 6 7,8,9 10 11 12 M - Modulating H - Convertible Two -Stage V - Two Stage S - Single Stage Motor C Variable Speed ECM / Communicating E - Multi -Speed ECM S - Multi -Speed PSC M BTU/h 040 - 40,000 BTU/h 100 - 100,000 BTU/h 060 - 60,000 BTU/h 120 - 120,000 BTU/h 080 - 80,000 BTU/h 140 - 140,000 BTU/h 13 14 Minor Revision A - Initial Release B - 1st Revision Major Revision A - Initial Release B - 1st Revision NOx N -Natural Gas X - Low NOx Cabinet Width A-14" C-21" B-17%" D-24W' Maximum CFM 2 - 800 CFM 3-1200CFM 4-1600CFM 5 - 2000 CFM 2 www.daikincomfort.com SS-DM80VC PRODUCT SPECIFICATIONS HEATING CAPACITY High Fire Input (BTU/h)' 60,000 60,000 80,000 80,000 80,000 High Fire Output (BTU/h)' (below) Natural Gas 48,000 48,000 64,000 64,000 64,000 LP Gas 48,000 48,000 64,000 64,000 64,000 Low Fire Input (BTU/h)' 42,000 42,000 56,000 56,000 56,000 Low Fire Output (BTU/h)1 (below) MIN1 M MEK811101 64,000 80,000 64,000 80,000 56,000 70,000 Natural Gas 33,600 33,600 44,800 44,800 44,800 44,800 56,000 LP Gas 33,600 33,600 44,800 44,800 44,800 44,800 56,000 AFUE1 80 80 80 80 80 80 80 Available AC@0.5"ESP 1.5-3.0 1.5-4.0 1.5-3.0 3.0-4.0 2.0-5.0 2.5-5.0 2.0-5.0 Temperature Rise Range (° F) 15-45 / 15-45 20-50 / 20-50 30-60 / 35-65 25-55 / 20-50 20-50 / 20-50 20-50 / 30-60 25-55 / 25-55 CIRCULATOR BLOWER Size (DxW) 10"x8" 10"x8" 10"x8" 11"x10" 10"x10" 11"x10" 10"x10" Horsepower- RPM % % 1/2 1/2 % 3/4 Speed Variable Variable Variable Variable Variable Variable Variable Vent Diameter' 4" 4" 4" 4" 4" 4" 4" No. of Burners 3 3 4 4 4 4 4 ELECTRICAL DATA Min. Circuit Ampacity4 7.75 10.6 7.75 7.75 10.6 10.6 10.6 Max. Overcurrent Device (amps) 5 15 15 15 15 15 15 15 SHIP WEIGHT (LBS) 105 107 110 118 121 129 124 Natural Gas BTU/h; for altitudes above from 0' to 4,500' above sea level, reduce input rating 4%for each 1,000' above 4,500' altitude. Low -fire rate is 70% of high -fire rate. a DOE AFUE based upon Isolated Combustion System (ICS) a Minimum Circuit Ampacity= (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. 4 Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit breakers of the same size as noted. NOTES • All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply. • Gas Service Connection %" FPT • Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes. SS-DM80VC www.daikincomfort.com 3 PRODUCT SPECIFICATIONS HEATING CAPACITY High Fire Input (BTU/h)' 60,000 80,000 80,000 100,000 High Fire Output (BTU/h)' (below) Natural Gas 48,000 64,000 64,000 80,000 LP Gas 48,000 64,000 64,000 80,000 Low Fire Input (BTU/h)' 42,000 56,000 56,000 70,000 Low Fire Output (BTU/h)1 (below) Natural Gas 33,600 44,800 44,800 56,000 LP Gas 33,600 44,800 44,800 56,000 AFUE1 80 80 80 80 Available AC@0.5"ESP 1.5-3.0 1.5-3.0 2.0-5.0 2.0-5.0 Temperature Rise Range (° F) 25-55 / 40-70 30-60 / 30-60 25-55 / 30-60 20-50 / 25-55 CIRCULATOR BLOWER Size (D x W) 10" x 8" 10" x 8" 10" x 10" 10" x 10" Horsepower - RPM Speed Variable Variable Variable Variable Vent Diameter' 4" 4" 4" 4" No. of Burners 3 4 4 5 ELECTRICAL DATA Min. Circuit Ampacity4 7.75 7.75 10.6 10.6 Max. Overcurrent Device (amps) 5 15 15 15 15 SHIP WEIGHT (LBS) 105 109 125 129 Natural Gas BTU/h; for altitudes above from 0' to 4,500' above sea level, reduce input rating 4%for each 1,000' above 4,500' altitude. Low -fire rate is 70% of high -fire rate. a DOE AFUE based upon Isolated Combustion System (ICS) a Minimum Circuit Ampacity= (1.25 x Circulator BlowerAmps) + ID Blower amps. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. 4 Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit breakers of the same size as noted. NOTES • All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply. • Gas Service Connection ''/:" FPT • Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes. 4 www.daikincomfort.com SS-DM80VC Alternate Gas Inlet Alt. Flue Outlet — Horizontal Left 1 / 11 B6 19Y=„ 1 33%" Alt. Gas Inlet High -Voltage Inlet 20 ! l 235/16' Alt. High Voltage 13'%" 15" Low -Voltage Inlet Alt. Low Voltage 23„ 28" MODEL DM80VC0603B*A 17%:" 28" 33%" DM80VC0604B*A 17%" 28" 33%" DM80VC0803B*A 17%" 28" 33%" DM80VC0804C*A 21" 28" 33%" DM80VC0805C*A 21" 28" 33%" DM80VC1005C*A 21" 28" 33%" DM80VC1005D*A 24%" 28" 33%" MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS Approved for line contact in the horizontal position. ' 24" clearance for serviceability recommended. 2 Single Wall Vent (SW) to be used only as a connector. Refer to the venting tables outlined in the Installation Manual for additional venting requirements. SS-DM80VC www.daikincomfort.com 5 DC80VC DIMENSIONS 18 %" A 3 % 28" 19%" B High -Voltage Electrical Low -Voltage , Electrical Gas Inlet O 0 0 O 0 0 0 MODELDIMENSIONS DC80VC0603BXA 17%" 28" 33%" DC80VC0803BXA 17%" 28" 33%" DC80VC0805CXA 21" 28" 33%" DC80VC1005CXA 21" 28" 33%" MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS C = If placed on combustible floor, the floor MUST be wood ONLY. Notes: • For servicing or cleaning, a 24" front clearance is recommended. • Unit connections (electrical, flue, and drain) may necessitate greater clearances than the minimum clearances listed above. • In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater. • Refer to the appropriate USA and Canadian codes: In the USA: the National Fuel Gas Code NFPA 54 / ANSI Z223.1 In Canada: the Canada National Standard of Canada, CAN/CSA 13149.1 and CAN/CSA 6142.2 www.daikincomfort.com SS-DM80VC 1�]►�E:i�l�l_�91=17►►li A rA DM80VC0603B*A* Cooling Speeds (@ .1" - .8" w.c. ESP) TAP ADJUST Minus 10% HIGH -STAGE 628 LoW-STAGE 421 Minus 5% 663 445 A Normal 698 468 Plus 5% 732 491 Plus 10% 768 515 Minus 10% 762 525 Minus 5% 804 555 B Normal 847 584 Plus 5% 889 613 Plus 10% 932 642 Minus 10% 930 664 Minus 5% 982 701 C Normal 1,034 738 Plus 5% 1,086 775 Plus 10% 1,137 812 Minus 10% 1,128 785 Minus 5% 1,190 828 D Normal 1,253 872 Plus 5% 1,316 915 Plus 10% 1,378 959 DM80VC0604B*A* COOLING SPEEDS (@ .1" - .8" w.c. ESP) TAP ADJUST HIGH -STAGE CIF Minus 10% 540 LoW-STAGE CFM 351 Minus 5% 570 371 A Normal 600 390 Plus 5% 630 410 Plus 10% 660 429 Minus 10% 720 468 Minus 5% 760 494 B Normal 800 520 Plus 5% 840 546 Plus 10% 880 572 Minus 10% 990 644 Minus 5% 1,045 679 C Normal 1,100 715 Plus 5% 1,155 751 Plus 10% 1,210 787 Minus 10% 1,260 819 Minus 5% 1,330 865 D Normal 1,400 910 Plus 5% 1,470 956 Plus 10% 1,540 1,001 DM80VC0603B*A* Heating Speeds (@ .1" - .5" w.c. ESP; Rise Range: 15° - 45°F) TAP ADJUST HIGH -STAGE LoW-STAGE RISE Minus 109/. 911 662 NA Minus 5% 961 698 NA A Normal 1,012 735 44 Plus 5% 1,063 772 42 Plus 10% 1,113 809 40 Minus 10% 988 724 45 Minus 5% 1,043 764 43 B Normal 1,098 804 40 Plus 5% 1,153 844 39 Plus 10% 1,208 884 37 Minus 10% 1,081 787 41 Minus 5% 1,141 830 39 C Normal 1,201 874 37 Plus 5% 1,261 918 35 Plus 10% 1,321 961 34 Minus 10% 1,179 841 38 Minus 5% 1,24S 887 36 D Normal 1,310 934 34 Plus 5% 1,376 981 32 Plus 10% 1,441 1,027 31 DM80VC0604B*A* HEATING SPEEDS (@ .1" - .5" w.c. ESP; RISE RANGE: 20° - WF) TAP ADJUST HIGH -STAGE LoW-STAGE RISE Minus 10% 1,125 788 40 Minus 5% 1,188 831 37 A Normal 1,250 875 36 Plus 5% 1,313 919 34 Plus 10% 1,375 963 32 Minus 10% 1,215 851 37 Minus 5% 1,283 898 35 B Normal 1,350 945 33 Plus 5% 1,418 992 31 Plus 10% 1,485 1,040 30 Minus 10% 1,305 914 34 Minus 5% 1,378 964 32 C Normal 1,450 1,015 31 Plus 5% 1,523 1,066 29 Plus 10% 1,595 1,117 28 Minus 10% 1,395 977 32 Minus 5% 1,473 1,031 30 D Normal 1,550 1,085 29 Plus 5% 1,628 1,139 27 Plus 10% 1,705 1,194 26 See Notes on page 10. SS-DM80VC www.daikincomfort.com DM80VC AIRFLOW DATA (CONT.) DM80VC0803B*A* COOLING SPEEDS (@ .1" - .8" w.c. ESP) TAP ADJUST Minus 10% HIGH -STAGE CIF 657 LoW-STAGE CFM 419 Minus 5% 694 442 A Normal 730 465 Plus 5% 767 488 Plus 10% 803 512 Minus 10% 790 526 Minus 5% 834 555 B Normal 878 584 Plus 5% 922 613 Plus 10% 966 642 Minus 10% 950 702 Minus 5% 1,003 741 C Normal 1,056 780 Plus 5% 1,109 819 Plus 10% 1,162 858 Minus 10% 1,102 832 Minus 5% 1,163 878 D Normal 1,224 924 Plus 5% 1,285 970 Plus 10% 1,346 1,016 DM80VC0804C*A* COOLING SPEEDS (@ .1" - .8" w.c. ESP) TAP ADJUST HIGH -STAGE LOW -STAG E Minus 10% 771 529 Minus 5% 814 559 A Normal 857 588 Plus 5% 900 617 Plus 10% 943 647 Minus 10% 946 668 Minus 5% 998 705 B Normal 1,051 742 Plus 5% 1,104 779 Plus 10% 1,156 816 Minus 10% 1,156 790 Minus 5% 1,220 834 C Normal 1,284 878 Plus 5% 1,348 922 Plus 10% 1,412 966 Minus 10% 1,454 944 Minus 5% 1,535 997 D Normal 1,616 1,049 Plus 5% 1,697 1,101 Plus 10% 1,778 1,154 DM80VC0803B*A* HEATING SPEEDS (@ .1" - .5" w.c. ESP; RISE RANGE 30°F - 60°F) TAP ADJUST HIGH -STAGE LoW-STAGE RISE Minus 10% 911 662 NA Minus 5% 961 698 NA A Normal 1,012 735 59 Plus 5% 1,063 772 56 Plus 10% 1,113 809 53 Minus 10% 988 724 60 Minus 5% 1,043 764 57 B Normal 1,098 804 54 Plus 5% 1,153 844 51 Plus 10% 1,208 884 49 Minus 10% 1,081 787 55 Minus 5% 1,141 830 52 C Normal 1,201 874 49 Plus 5% 1,261 918 47 Plus 10% 1,321 961 45 Minus 10% 1,179 841 50 Minus 5% 1,245 887 48 D Normal 1,310 934 45 Plus 5% 1,376 981 43 Plus 10% 1,441 1,027 41 DM80VC0804C*A* HEATING SPEEDS (@ .1" - .5" w.c. ESP; RISE RANGE: 25°F - 557) TAP ADJUST Minus 10% HIGH -STAGE 1,111 LOW -STAGE 817 RISE 53 Minus 5% 1,172 863 51 A Normal 1,234 908 48 Plus 5% 1,296 953 46 Plus 10% 1,357 999 44 Minus 10% 1,229 887 48 Minus 5% 1,297 937 46 B Normal 1,365 986 43 Plus 5% 1,433 1,035 41 Plus 10% 1,502 1,085 39 Minus 10% 1,351 955 44 Minus 5% 1,426 1,008 42 C Normal 1,501 1,061 39 Plus 5% 1,576 1,114 38 Plus 10% 1,651 1,167 36 Minus 10% 1,456 1,028 41 Minus 5% 1,537 1,085 39 D Normal 1,618 1,142 37 Plus 5% 1,699 1,199 35 Plus 10% 1,780 1,256 33 See Notes on page 10. www.daikincomfort.com SS-DM80VC DM80VC AIRFLOW DATA (CONT.) DM80VC0805C*A* Cooling Speeds (@ .1" - .8" w.c. ESP) TAP ADJUST Minus 10% HIGH -STAGE 720 LoW-STAGE 468 Minus 5% 760 494 A Normal 800 520 Plus 5% 840 546 Plus 10% 880 572 Minus 10% 990 644 Minus 5% 1,045 679 B Normal 1,100 715 Plus 5% 1,155 751 Plus 10% 1,210 787 Minus 10% 1,260 819 Minus 5% 1,330 865 C Normal 1,400 910 Plus 5% 1,470 956 Plus 10% 1,540 1,001 Minus 10% 1,620 1,053 Minus 5% 1,710 1,112 D Normal 1,800 1,170 Plus 5% 1,890 1,229 Plus 10% 1,980 1,287 DM80VC0805D*A* Cooling Speeds (@ .1" - .8" w.c. ESP) 7Minus747 524 789 553 A 830 582 Plus 5% 872 611 Plus 10% 913 640 Minus 10% 1,025 707 Minus 5% 1,082 747 B Normal 1,139 786 Plus 5% 1,196 825 Plus 10% 1,253 865 Minus 10% 1,405 942 Minus 5% 1,483 995 C Normal 1,561 1,047 Plus 5% 1,639 1,099 Plus 10% 1,717 1,152 Minus 10% 1,769 1,193 Minus 5% 1,868 1,260 D Normal 1,966 1,326 Plus 5% 2,064 1,392 Plus 10% 2,163 1,459 DM80VC0805C*A* Heating Speeds (@ .1" - .5" w.c. ESP; Rise Range: 20' - 50°F) TAP ADJUST HIGH -STAGE LoW-STAGE RISE Minus 10% 1,350 945 44 Minus 5% 1,425 998 42 A Normal 1,500 1,050 40 Plus 5% 1,575 1,103 38 Plus 10% 1,650 1,155 36 Minus 10% 1,440 1,008 41 Minus 5% 1,520 1,064 40 B Normal 1,600 1,120 37 Plus 5% 1,680 1,176 35 Plus 10% 1,760 1,232 1 34 Minus 10% 1,530 1,071 39 Minus 5% 1,615 1,131 37 C Normal 1,700 1,190 35 Plus 5% 1,785 1,250 33 Plus 10% 1,870 1,309 32 Minus 10% 1,620 1,134 37 Minus 5% 1,710 1,197 35 D Normal 1,800 1,260 33 Plus 5% 1,890 1,323 31 Plus 10% 1,980 1,386 30 DM80VC0805D*A* Heating Speeds (@ .1" - .5" w.c. ESP; Rise Range: 20° - 50°F) TAP ADJUST Minus 10% 1,798 1,247 33 Minus 59/. 1,898 1,317 31 A Normal 1,998 1,386 30 Plus 5% 2,098 1,455 28 Plus 10% 2,198 1,525 27 Minus 10% 1,806 1,265 33 Minus 5% 1,907 1,335 31 B Normal 2,007 1,405 30 Plus 5% 2,107 1,475 28 Plus 10% 2,208 1,546 27 Minus 10% 1,820 1,274 33 Minus 59/. 1,921 1,344 31 C Normal 2,022 1,415 29 Plus 5% 2,123 1,486 28 Plus 10% 2,224 1,557 27 Minus 109/o 1,842 1,292 32 Minus 59/. 1,945 1,363 30 D Normal 2,047 1,435 29 Plus 5% 2,149 1,507 28 Plus 10% 2,252 1,579 26 See Notes on page 10. SS-DM80VC www.daikincomfort.com DM80VC AIRFLOW DATA (CONT.) DM80VC1005C*A COOLING SPEEDS (@ T' - .8" w.c. ESP) ADJUST Minus 10% HIGH -STAGE CFIVI 720 Low -STAGE CFM 468 Minus 5% 760 494 A Normal 800 520 Plus 5% 840 546 Plus 10% 880 572 Minus 10% 990 644 Minus 5% 1,045 679 B Normal 1,100 715 Plus 5% 1,155 751 Plus 10% 1,210 787 Minus 10% 1,260 819 Minus 5% 1,330 865 C Normal 1,400 910 Plus 5% 1,470 956 Plus 10% 1,540 1,001 Minus 10% 1,620 1,053 Minus 5% 1,710 1,112 D Normal 1,800 1,170 Plus 5% 1,890 1,229 Plus 10% 1,980 1,287 DM80VC1005C*A HEATING SPEEDS (@ X' - .5" w.c. ESP; RISE RANGE: 25° - 55•F) TAP ADJUST HIGH -STAGE LoW-STAGE RISE Minus 10% 1,553 1,089 48 Minus 5% 1,639 1,150 45 A Normal 1,725 1,210 43 Plus 5% 1,811 1,271 41 Plus 10% 1,898 1,331 39 Minus 10% 1,575 1,103 47 Minus 5% 1,663 1,164 45 B Normal 1,750 1,225 42 Plus 5% 1,838 1,286 40 Plus 10% 1,925 1,348 38 Minus 10% 1,598 1,121 46 Minus 5% 1,686 1,183 44 C Normal 1,775 1,245 42 Plus 5% 1,864 1,307 40 Plus 10% 1,953 1,370 38 Minus 10% 1,620 1,134 46 Minus 5% 1,710 1,197 43 D Normal 1,800 1,260 41 Plus 5% 1,890 1,323 39 Plus 10% 1,980 1,386 37 NOTES • These charts are for furnaces installed at 0' - 4,500'. At higher altitudes, a properly de -rated unit will have the same temperature rise at a particular CFM, while the ESP at that CFM will be lower. • The installation must be adjusted to obtain a temperature rise within the range listed on the furnace nameplate. • Do not operate above .5" w.c. ESP in heating mode. • Propane gas installations will have a high -stage rise approximately 47 lower than shown in the tables. MINIMUM FILTER SIZES Filter Size (in 2) (1) 16 x 25 (Side or Bottom) F (1) 16 x 25 (Side or Bottom)' 1 (2) 16 x 25 (Side) or (1) 20 x 25 (Bottom) Note: Other size filters of equal or greater surface area may be used; filters may also be centrally located. ' Use 2 -16 X 25 filters on side returns or 20 X 25 filter on bottom return if furnace is connected to a cooling unit over 4 tons nominal capacity. 10 www.daikincomfort.com SS-DM80VC _�91=17►►li A rA DC80VC0603BXA* COOLING SPEEDS (@ .1" - .8" w.c. ESP) TAP ADJUST Minus 10% HIGH -STAGE LoW-STAGEJ 568 371 Minus 5% 599 391 A Normal 631 412 Plus 5% 663 433 Plus 10% 694 453 Minus 10% 755 513 Minus 5% 797 542 B Normal 839 570 Plus 5% 881 599 Plus 10% 923 627 Minus 10% 945 646 Minus 5% 998 682 C Normal 1,050 718 Plus 5% 1,103 754 Plus 10% 1,155 790 Minus 10% 1,115 758 Minus 5% 1,177 800 D Normal 1,239 842 Plus 5% 1,301 884 Plus 10% 1,363 926 DC80VC0803BXA* COOLING SPEEDS (@ .1" - .8" W.C. ESP) TAP HIGH -STAGE LoW-STAGEE ADJUST C C'M Minus 10% 579 381 Minus 5% 611 402 A Normal 643 423 Plus 5% 675 444 Plus 10% 707 465 Minus 10% 704 524 Minus 5% 743 553 B Normal 782 582 Plus 5% 821 611 Plus 10% 860 640 Minus 10% 884 621 Minus 5% 928 656 C Normal 982 690 Plus 5% 1,031 725 Plus 10% 1,080 759 Minus 10% 1,080 722 Minus 5% 1,140 762 D Normal 1,200 802 Plus 5% 1,260 842 Plus 10% 1,320 882 DC80VC0603BXA* HEATING SPEEDS (@ .1" - .5" w.c. ESP; RISE RANGE: 25° - SS°F); NR = NOT RECOMMENDED TAP ADJUST Minus 10% HIGH -STAGE 996 Low -STAGE 706 RISE 45 Minus 5% 1,052 745 42 A Normal 1,107 784 40 Plus 5% 1,162 823 38 Plus 10% 1,218 862 36 Minus 10% 1,078 766 41 Minus 5% 1,138 808 39 B Normal 1,198 851 37 Plus 5% 1,258 894 35 Plus 10% 1,318 936 34 Minus 10% 1,184 830 38 Minus 5% 1,250 876 36 C Normal 1,316 922 34 Plus 5% 1,382 968 32 Plus 10% 1,448 1,014 31 Minus 10% 1,266 865 35 Minus 5% 1,337 913 33 D Normal 1,407 961 32 Plus 5% 1,477 1,009 30 Plus 10% 1,548 1,057 29 DC80VC0803BXA* HEATING SPEEDS (@ .1" - .5" W.C. ESP; RISE RANGE: 30' - 60'F;) NR = NOT RECOMMENDED TAP ADJUST Minus 10% HIGH -STAGE 843 LoW-STAGE 621 RISE NR Minus 5% 890 656 NR A Normal 937 690 NR Plus 5% 984 725 60 Plus 10% 1,031 759 57 Minus 10% 940 669 NR Minus 5% 993 706 60 B Normal 1,045 743 57 Plus 5% 1,097 780 54 Plus 10% 1,149 817 52 Minus 10% 1,039 726 57 Minus 5% 1,097 767 54 C Normal 1,155 807 51 Plus 5% 1,213 847 49 Plus 10% 1,270 888 47 Minus 10% 1,127 783 53 Minus 5% 1,191 827 50 D Normal 1,254 870 47 Plus 5% 1,317 914 45 Plus 10% 1,379 957 43 See Notes on page 12. SS-DM80VC www.daikincomfort.com 11 DC80VCAIRFLOW DATA (CONT.) DC80VC0805CXA* COOLING SPEEDS (@ .1" - .8" w.c. ESP) TAP ADJUST HIGH -STAGE LoW-STAGE1 Minus 10% 735 479 Minus 5% 776 505 A Normal 817 532 Plus 5% 858 559 Plus 10% 899 585 Minus 109/6 1,011 659 Minus 5% 1067 695 B Normal 1123 732 Plus 59/6 1,179 769 Plus 10% 1235 805 Minus 10% 1,301 848 Minus 59/6 1373 895 C Normal 1445 942 Plus 59/. 1,517 989 Plus 10% 1,590 1036 Minus 109/6 1,675 1077 Minus 5% 1768 1,137 D Normal 1861 1197 Plus 5% 1954 1 257 Plus 10% 2 047 1,317 DC80VC1005CXA* COOLING SPEEDS (@ .1" - .8" w.c. ESP) TAP ADJUST Minus 10% 763 500 Minus 5% 806 528 A Normal 848 556 Plus 5% 890 584 Plus 10% 933 612 Minus 10% 1059 754 Minus 5% 1,118 796 B Normal 1,177 838 Plus 5% 1236 880 Plus 10% 1,295 922 Minus 10% 1,332 928 Minus 5% 1,406 979 C Normal 1480 1031 Plus 5% 1,554 1,083 Plus 10% 1,628 1,134 Minus 10% 1,693 1,169 Minus 5% 1,787 1,234 D Normal 1,881 1,299 Plus 59/o 1975 1,364 Plus 10% 2,069 1,429 DC80VC0805CXA* HEATING SPEEDS (@ .1" - .5" w.c. ESP; RISE RANGE: 30° - 60°F; NR = NOT RECOMMENDED) TAP ADJUST Minus 10% HIGH -STAGE 1,261 LOW -STAGE 878 RISE 47 Minus 5% 1331 927 45 A Normal 1401 976 42 Plus 5% 1471 1025 40 Plus 10% 1541 1074 38 Minus 10% 1,346 943 44 Minus 5% 1420 996 42 B Normal 1495 1048 40 Plus 5% 1570 1,100 38 Plus 10% 1645 1,153 36 Minus 10% 1421 1009 42 Minus 5% 1500 1065 40 C Normal 1579 1121 38 Plus 5% 1,658 1,177 36 Plus 10% 1737 1,233 34 Minus 10% 1,516 1073 39 Minus 5% 1,600 1,132 37 D Normal 1684 1192 35 Plus 5% 1,768 1 252311 34 Plus 10% 1852 1, 32 DC80VC1005CXA* HEATING SPEEDS (@ X' - .5" w.c. ESP; (RISE RANGE: 20° - 50'F) 7orm 1432 1,035 NR 1,511 1,093 49 A1591 1150 47 1,671 1,208 44 Plus 10% 1750 1,265 42 Minus 109/. 1481 1069 50 Minus 5% 1,564 1,129 47 B Normal 1,646 1,188 45 Plus 5% 1728 1,247 43 Plus 10% 1811 1307 41 Minus 10% 1532 1090 48 Minus 5% 1,617 1,150 46 C Normal 1702 1211 44 Plus 5% 1,787 1,272 41 Plus 10% 1,872 1332 40 Minus 10% 1,611 1,156 46 Minus 5% 1701 1,220 44 D Normal 1,790 1,284 41 Plus 5% 1880 1,348 39 Plus 10% 1,969 1,412 38 Notes: • These charts are for furnaces installed at 0'- 4,500'. At higher altitudes, a properly de -rated unit will have the same temperature rise at a particular CFM, while the ESP at that CFM will be lower. • The installation must be adjusted to obtain a temperature rise within the range listed on the furnace nameplate. • In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater. • Do not operate above .5" w.c. ESP in heating mode. • Propane gas installations will have a high -stage rise approximately 4° lower than shown in the tables. CONTINUOUS FAN SPEEDS 12 www.daikincomfort.com SS-DM80VC V) b 00 00 0 Q a, 0 3 0 0 0 3 N w BTU OUTPUT VS. TEMPERATURE RISE CHART 100 90 80 70 w LLI 60 Q w 50 w F- 40 30 20 10 30 40 50 60 70 80 90 100 110 120 130 140 150 OUTPUT BTU/H X 1,000 600 CFM goo soo 900 1000 1100 1200 1400 1600 1800 2000 2200 CFM 400 FORMULAS BTU/h Output = CFM x 1.08 x Rise BTU/H Output Rise = CFM x 1.08 m v m C m m z c) m n 2 WIRING DIAGRAM ID BLOWER TWO -STAGE PRESSURE p SWITCH ASSEMBLY HOT LOW FIRE 24V HUM. SURFACE IGNITER PRESSURE YL D 2 CIRCUIT SWITCH No CONNECTOR TWO STAGE HIGH FIRE GAS VALVE PRESSURE SWITCH (HONEYWELL) l,L C 3 BL HI 2 H PM 1 BR MANUAL RESET ROLLOUT LIMIT AUTO RESET PRIMARY CONTROLS LIMIT CO ROL PU PU RD PU 3 WH INDUCED DRAFT 2 RD BLOWER 1 BK of lonlco rrn4oq.TnncnlT GND ( BLOWER COMPARTMENT F 0 I e o ILINE o W COOL IF m C r G) m ° c Q Z TRIM % A. O r COOL PRFL E, DOm GND TO 115 VAC/ 10 /60 HZ POWER SUPPLY WITH C OVERCURRENT n PROTECTION DEVICE 0 L O WARNING: DISCONNECT DO BK POWER BEFORE 0 N SERVICING. WIRING H TO UNIT MUST BE DISCONNECT PROPERLY POLARIZED AND GROUNDED. TO 115VAC/ 10 /60 HZ POWER SUPPLY WITH OVERCURRENT PROTECTION DEVICE FLAME SENSOR WARNING: L m i DISCONNECT POWER T BEFORE SERVICING. WIRING TO UNIT MUST BE PROPERLY POLARIZED AND GROUNDED. DISCONNECT O 0 co D I 1 � 41 r+ N SWITCH L J L J G' JUNCTION C BOX A c INDUCTOR COIL Z (ON SOME MODELS) O INDOOR R AWIR RCUC Z BL AUTO RESET y AUXILIARY LIMIT CONTROL (TWO ON SOME MODELS) 0 z A 0 i o I BL RD �� #W GND -IN LINE NEUTRAL SEE NOTE b HUMIDIFIER HUMOUT HUMIDIFIER \0 NEUTRAL 1 ELECTRONIC L NEUTRAL r M. AIR CLEANER z ND HI NEUTRAL ID p BLWR ++ IND LO NEUTRAL 0 HOT SURFACE IGNITER FLAME SENSOR LINE 115 VAC NEUTRAL 40 VA 3 A TH (4) TRANSFORMER jSE 34 VAC AUTO RESET AUXILIARY LIMIT AUTO RESET PRIMARY CONTROLS (TWO ON SOME MODELS) LIMITCO_N`TROL m a I HLO 10 W = HEAT IF m E BK y Vi 1 14 © )EHUM ENABL m ? 24 p PSO T TRIM ENABLE m V+ VAC y LOW FIRE PRESS. O 10 1 12 CENT FAN m m i m 115 y Wt PSi 2 241 HUM. SWITCH ® AOA n r A ' B HEAT OFF IDLY m m¢ y VAC z NO 4 5 b m O m m W NO T-STAY 40 VA y I TO O 1 2 © RANSFORME /'� C { SEE ® DIAGNOSTIC Z� MICRO HIGH FIRE NOTES ® LED'S (^�II PRESS.SWTICH MANUAL RESET ROLLOUT o LIMIT CONTROLS C m I 24V Mar c1 ? N N o WH p HLI 1 3A o o e e s e s a o FUSE 24 V THERMOSTAT CONNECTIONS a MVL 13 PM MVH 14 HI WH �,C MVC(B) ECM MTR KU HARNESS BK BK IGND (5) VALVE TR (111 GND *1P BK TO I GND (4) �+voc (1) GND BLOWERRI (2) INDOOR COMPARTMENT TO _ AIR DOOR SWITCH MICROTX (3) CIRCULATOR (OPEN WHEN BLWR CIRCULATOR INDUCTOR COIL DOOR OPEN) BLOWER (ON SOME MODELS) LINTEGRATED CONTROL MODULE - HUMIDIFIER - J NOTES: SET HEAT ON R.-VTHERMOSTATCOLOR CODES: LOW VOLTAGE (24V) EQUIPMENT GND ri7 . MANUFgCTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING. PK PINK 1 LOW VOLTAGE FIELD FIELD GND 3.%NYOF THE ORIGINAL WIRE AS SUPPLIEDWITH THE FURNACE MUST BE REPLACED, BRBROWN IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE RATING OF VyH WHITE HI VOLTAGE 115V b AT LEAST 1Dfi.c. USE c.PPER c.NDUCTORSONLY. ( ) FIELD SPLICE 4. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C. AND LOCAL CODES. BL BLUE HI VOLTAGE FIELD S. TO RECALL THE LAST 6 FAULTS. MOST RECENT TO LEAST RECENT, DEPRESS SWITCH FOR MORE GY GRAY SWITCH (TEMP.) THAN 2 SECONDS WHILE IN STANDBY THERMOSTAT INPUTS) RD RED JUNCTION USE HUM TERMINAL TO RUN HUMIDIFIERDURINGHEAT CALL YL YELLOW IGNITER (COMMUNICATING OR LEGACY MODES). USEHUNHN AND HUM -OUT TERMINALS TO RUN TERM INAL cAI(N1.1 MUNICATINGMODEORLEGACY MODEI oR INDEPENDENTLY OR ORANGE INTERNAL TO SWITCH PRESS. FROM HEAT CALL(COMMUNICATING MODE ONLY -SETUP IS DONE WITHIN COMMUNICATING PU PURPLE ( ) THERMOSTAT) INTEGRATED CONTROL GN GREEN OVERCURRENT EE3 BK BLACK PLUG CONNECTION PROT. DEVICE 0140F02299-A ' u 14 www.daikincomfort.com SS-DM80VC ACCESSORIES MODEL AM 11-1425-FA AM11-1625-FB Deep Pleated Media Air Cleaner AM 11-2025-FC AM 11-2525-F D ASAS Electronic Air Cleaners (sizes=-10,-11,-12 or-18) AFE18-60A Fossil Fuel Kit (must be used in a dual -fuel application with a compatible thermostat) HA-02 High Altitude Kit LPM-06 LP Conversion Kit (Springs & Orifice)' ' White -Rodgers and Honeywell valves SS-DM80VC www.daikincomfort.com 15 NOTES Our continuing commitment to quality products may mean a change in specifications without notice. © 2021 DA/K/NMANUFACTUR/NGCOMPANY. L.P. • Houston, Texas • Printed in the USA. 16 www.daikincomfort.com SS-DM80VC