Loading...
BLD2022-0988_Manufacturer_Specifications_and_Installation_Instructions_7.25.2022_1.46.23_PM_3010201r DA/K/N ,FIT' UP TO 18 SEER & 10.0 HSPF 12To5ToNs COOLING CAPACITY-17,100 - 54,000 BTU/H HEATING CAPACITY 17,100 - 54,000 BTU/H DZI 7VSA DAIKIN FIT HIGH -EFFICIENCY, COMMUNICATING, VARIABLE -SPEED, INVERTER DRIVE SIDE DISCHARGE Contents Nomenclature ........................................ 2 Product Specifications ........................... 3 Expanded Cooling Data.........................4 Expanded Heating Data.......................18 Performance Data ! " Standard Mode ............................... 20 g ftm Mode ..................................... 22 \`\\\Boost 240000a� Sound Power Levels ............................ 24 ,\ MOMME& AHRI Ratings (see note) ....................... 25 ` Dimensions .......................................... 26 11 0 Wiring Diagrams..................................27 gm ►.,: \\O Accessories .......................................... 29 Standard Features • Daikin variable -speed swing compressors • High -density foam compressor sound blanket • Compatible with Daikin One+ smart thermostat and other Daikin communicating equipment • Daikin control algorithmic logic • Intelligent Defrost Mode • In communicating mode, only two low - voltage wires to outdoor unit required • Diagnostic indicator lights, seven -segment LED display, and fault code storage • Daikin Inside intelligence for diagnostics • Field -selectable boost mode increases compressor speed during unusually high loads • Quiet DC outdoor fan motor • Field -installed bi-flow filter drier • Coil and ambient temperature sensors • Suction pressure transducer • Sweat connection service valves with easy access to gauge ports • Advanced water -shedding drain pan • Hot start technology • AHRI Certified; ETL Listed SPLIT SYSTEM HEAT PUMP I Cabinet Features • Heavy -gauge galvanized steel cabinet with grille -style sound control side design • Custom Ivory white powder -paint finish • 500-hour salt -spray tested • Wire fan discharge grille • Top and side maintenance access • When properly anchored, meets the 2017 Florida Building Code unit integrity requirements for hurricane -type winds (Anchor bracket kits available.) 12 YEAR 12 YEAR 11 Oil UNIT PARTS XM. CERTIFIED' REPLACEMENTI/ LIMITED LIMITED WARRANTY WARRANTY * Complete warranty details available from your local dealer or at www.daikincomfort.com. To receive the 12-Year Unit Replacement Limited Warranty and 12-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Additional requirements for annual maintenance are required for the Unit Replacement Limited Warranty. Online registration and some of the additional requirements are not required in California or Quebec. SS-DZI7VSA www.daikincomfort.com 01/20 Supercede 12/19 NOMENCLATURE D Z 17 V S A 36 1 AA 1 2 3,4 5 6 7 8,9 10 11,12 Brand Engineering D - Daikin Major &Minor revisions Type X - AC R-410A Z - H P R-410A SEER 14 - 14 SEER 18 - 18 SEER 16-16SEER 20-20SEER 17-17SEER Compressor S - Single Stage V - Variable Speed T - Two Stage A - Base C- Communicating D - Deluxe Voltage 1- 208/230 V Single -Phase 60 Hz Capacity 18 - 1% tons 42 - 3Y2 tons 24 - 2 tons 48 - 4 tons 30 - 2%z tons 60 - 5 tons 36 - 3 tons Region N-North S-Southeast & North A -AI I Feature Set N - Nominal S - Side Discharge Communicating 2 www.daikincomfort.com SS-DZ17VSA PRODUCT SPECIFICATIONS .0 CAPACITIES AND RATINGS' Cooling (BTU/h) 17,100 22,800 28,400 34,200 40,000 45,500 54,000 Heating (BTU/h) 17,100 22,800 28,400 34,200 40,000 45,500 54,000 AMBIENT OPERATION RANGE Cooling (°FDB(°CDB)) 0 to 115 (-17.8 to 46.1)2 Heating (°FDB(°CDB)) -20 to 70 (-29.9 to 21.1)3 COMPRESSOR Type Swing Swing Swing Swing Swing Swing Swing RLA 10.5 15.2 20.0 20.0 27.0 27.0 29.0 CONDENSER FAN MOTOR Horsepower 3/16 3/16 /16 3/16 Y4 Y4 X FLA 2.18 2.18 2.70 2.70 2.50 2.50 2.50 REFRIGERATION SYSTEM Refrigerant Line Size Liquid Line Size ("O.D.) %11 %11 %11 %11 %" %11 %11 Suction Line Size ("O.D.) %" %" %8" %8" 1%B" 1%8" 1 8 Refrigerant Connection Size Liquid Valve Size ("O.D.) 3/8" 3/8" %8" %8" %" %11 W. Suction Valve Size ("O.D.) %" %" %8" B" %8" %B" %8" Valve Connection Type Front Sealing Front Sealing Front Sealiing Front Sealing Front and Front and Front and Back Sealing Back Sealing Back Sealing Refrigerant Charge (oz.) 81 81 88 88 118 118 127 Expansion Device EEV EEV EEV EEV EEV EEV EEV Superheat at Service Valve Auto -control Auto -control Auto -control Auto -control Auto -control Auto -control Auto -control Subcooling at Service Valve 10±1°F 12±1°F 14±1°F 14±1°F 10±1°F 8±1°F 9±1°F ELECTRICAL DATA Volts-Phase(60 Hz) 208/230-1 208/230-1 208/230-1 208/230-1 208/230-1 208/230-1 208/230-1 Minimum Circuit Ampacity2 12.7 17.4 22.7 22.7 34.5 34.5 36.5 Max. Overcurrent Protection 15 20 25 25 35 35 40 Min / Max Volts 197/253 197/253 197/253 197/253 197/253 197/253 197/253 Electrical Conduit Size %" %" %" %" %" or W W. or W %" or W EQUIPMENT WEIGHT (LBS) 116 116 125 131 170 170 183 SHIP WEIGHT (LBS) 135 135 143 150 185 185 198 Tested and rated in accordance with ANSI/AHRI Standard 210/240 Z Line set length should be <=50 ft if normal cooling mode ambient temperature is below 14°F (applies to select sizes, see Installation Instructions for details) a Line set length >= 30 ft will have heating operation lockout at 15"F Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes s Must use time -delay fuses or HACR-type circuit breakers of the same size as noted. NOTES • Always check the S&R plate for electrical data on the unit being installed. • System charge must be adjusted per Installation Instructions Final Charge Procedure. SS-DZ17VSA www.daikincomfort.com OUTDOOR AMBIENT TEMPERATURE 65°F 75*F 85°F 95°F 105°F 115°F ENTERING INDOOR WET BULB TEMPERATURE .: Capacity 17.5 17.8 18.1 - 17.2 17.5 18.0 - 16.8 17.0 17.5 - 16.0 16.2 16.7 - 15.0 15.3 15.8 - 14.1 14.4 14.9 - S/T 0.60 0.53 0.39 0.62 0.54 0.40 0.64 0.57 0.42 0.66 0.59 0.44 1.00 0.61 0.47 1.00 0.66 0.52 Evap dT 21 19 14 19 18 14 20 18 15 19 18 14 19 17 14 20 19 15 520 PrSuc 124 126 128 131 132 136 137 139 142 143 145 148 149 150 153 158 159 163 PrDis 243 244 245 280 281 283 320 321 323 363 364 366 410 411 412 463 464 465 ODAmps 3.4 3.4 3.7 4.3 4.3 4.3 4.9 4.9 4.9 5.6 5.6 5.6 6.4 6.4 6.3 7.2 7.2 7.2 TotalPower 892 894 953 1,085 1,084 1,082 1,229 1,228 1,226 1,386 1,385 1,382 1,560 1,559 1,557 1764 1763 1761 Capacity 17.8 17.9 18.4 17.5 17.7 18.2 17.0 17.3 17.8 16.2 16.5 17.0 15.3 15.5 16.0 14.4 14.7 15.2 S/T 0.68 0.61 0.47 0.70 0.62 0.48 0.72 0.64 0.50 1.00 0.66 0.52 1.00 0.69 0.55 1.00 0.74 0.60 Evap dT 19 16 13 18 16 13 18 17 13 18 16 13 18 16 13 19 17 14 70 610 PrSuc 127 127 130 133 135 138 140 141 144 145 147 150 151 152 155 160 161 165 PrDis 246 245 247 282 284 285 323 324 325 366 367 368 412 413 415 465 466 468 ODAmps 3.5 3.8 3.8 4.3 4.3 4.3 5.0 5.0 4.9 5.6 5.6 5.6 6.4 6.4 6.4 7.3 7.3 7.3 TotalPower 902 963 961 1093 1092 1090 1238 1237 1234 1394 1393 1390 1568 1567 1565 1773 1772 1769 Capacity 18.0 18.2 18.7 17.8 18.1 18.6 17.4 17.6 18.1 16.6 16.8 17.3 15.6 15.9 16.4 14.8 15.0 15.5 S/T 0.73 0.65 0.51 0.74 0.66 0.52 0.76 0.68 0.54 1.00 0.70 0.56 1.00 0.73 0.59 1.00 1.00 0.64 Evap dT 17 15 12 17 15 12 17 16 12 17 15 12 17 15 12 18 16 13 700 PrSuc 128 130 133 136 137 140 142 144 147 148 149 152 153 155 158 162 164 167 PrDis 247 248 249 285 286 288 325 326 328 368 369 371 415 416 417 468 469 470 ODAmps 3.8 3.8 3.8 4.4 4.4 4.3 5.0 5.0 5.0 5.7 5.7 5.7 6.4 6.4 6.4 7.3 7.3 7.3 TotalPower 971 970 968 1100 1099 1097 1244 1243 1241 1400 1399 1397 1575 1574 1572 1779 1778 1776 Capacity 17.5 17.8 18.1 18.9 17.2 17.5 18.0 18.8 16.8 17.0 17.5 18.3 16.0 16.2 16.7 17.5 15.0 15.3 15.8 16.6 14.2 14.4 14.9 15.7 S/T 0.74 0.66 0.53 0.38 0.75 0.67 0.53 0.38 1.00 0.70 0.56 0.41 1.00 0.72 0.58 0.43 1.00 0.74 0.60 0.45 1.00 1.00 0.65 0.51 Evap dT 25 23 18 15 23 22 18 15 24 22 19 15 23 22 18 15 23 21 18 15 24 22 19 16 520 PrSuc 124 126 128 133 131 132 136 141 138 139 142 147 143 145 148 153 149 150 153 159 158 159 163 168 PrDis 243 244 245 249 280 281 283 287 320 321 323 327 363 364 366 370 410 411 413 417 463 464 466 470 ODAmps 3.4 3.4 3.7 3.8 4.3 4.3 4.3 4.3 4.9 4.9 4.9 4.9 5.6 5.6 5.6 5.6 6.4 6.4 6.3 6.4 7.2 7.2 7.2 7.3 TotalPower 891 893 9S2 962 1084 1083 1081 1091 1229 1228 1225 1235 1385 1384 1381 1391 1559 1558 1556 1566 1764 1763 1760 1770 Capacity 17.9 17.9 18.4 19.2 17.5 17.7 18.3 19.0 17.0 17.3 17.8 18.6 16.2 16.5 17.0 17.8 15.3 15.5 16.1 16.9 14.4 14.7 15.2 16.0 S/T 0.82 0.74 0.60 0.46 0.83 0.75 0.61 0.46 1.00 0.78 0.64 0.49 1.00 0.80 0.66 0.51 1.00 0.82 0.68 0.53 1.00 1.00 0.73 0.58 Evap dT 24 20 17 14 22 20 17 14 22 21 17 14 22 20 17 14 22 20 17 13 23 21 18 14 75 610 PrSuc 127 127 130 136 133 135 138 143 140 141 144 150 145 147 150 155 151 152 155 161 160 162 165 170 PrDis 246 246 247 251 283 284 285 290 323 324 325 330 366 367 369 373 412 413 415 419 465 466 468 472 ODAmps 3.5 3.8 3.8 3.8 4.3 4.3 4.3 4.4 5.0 4.9 4.9 5.0 5.6 5.6 5.6 5.7 6.4 6.4 6.4 6.4 7.3 7.3 7.3 7.3 TotalPower 901 962 960 970 1092 1091 1089 1099 1237 1236 1234 1243 1393 1392 1390 1400 1567 1566 1564 1574 1772 1771 1769 1778 Capacity 18.0 18.2 18.7 19.5 17.8 18.1 18.6 19.4 17.4 17.6 18.1 18.9 16.6 16.8 17.4 18.1 15.6 15.9 16.4 17.2 14.8 15.0 15.5 16.3 S/T 0.86 0.78 0.64 0.50 1.00 0.79 0.65 0.50 1.00 0.82 0.68 0.53 1.00 0.84 0.70 0.55 1.00 1.00 0.72 0.57 1.00 1.00 0.77 0.62 Evap dT 21 19 16 12 21 19 16 12 21 19 16 13 21 19 16 12 21 19 16 12 22 20 17 13 700 PrSuc 128 130 133 138 136 137 140 146 142 144 147 152 148 149 152 158 153 155 158 163 162 164 167 173 PrDis 247 248 250 254 285 286 288 292 325 326 328 332 368 369 371 375 415 416 417 422 468 469 471 475 ODAmps 3.8 3.8 3.8 3.8 4.4 4.4 4.3 4.4 5.0 5.0 5.0 5.0 5.7 5.7 5.6 5.7 6.4 6.4 6.4 6.4 7.3 7.3 7.3 7.3 TotalPower 970 969 967 977 1099 1098 1096 1106 1243 1242 1240 1250 1400 1399 1396 1406 1574 1573 1571 1581 1779 1777 1775 1785 IDB*: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. Shaded area reflects ACCA (TVA) Airflow may vary depending on actual ambient conditions and system operation modes. kW =Total system power Amps = outdoor unit amps x n n Q fl, 77 0 3 0 0 0 0 91 OUTDOOR AMBIENT TEMPERATURE 650F 75*F 850E 950F 105*F 115"F ENTERING INDOOR WET BULB TEMPERATURE ): Capacity 17.6 17.9 18.2 19.0 17.3 17.6 18.1 18.9 16.9 17.1 17.6 18.4 16.1 16.3 16.8 17.6 15.1 15.4 15.9 16.7 14.2 14.5 15.0 15.8 S/T 1.00 0.79 0.66 0.51 1.00 0.80 0.66 0.51 1.00 0.83 0.69 0.54 1.00 0.85 0.71 0.56 1.00 1.00 0.73 0.58 1.00 1.00 0.78 0.64 Evap dT 30 27 22 19 27 26 22 19 28 26 22 19 27 26 22 19 27 25 22 19 28 26 23 20 520 PrSuc 125 127 129 134 131 133 136 141 138 140 143 148 144 145 148 154 149 151 154 159 158 160 163 168 PrDis 244 245 245 249 281 282 283 288 321 322 323 328 364 365 367 371 410 411 413 417 463 464 466 470 ODAmps 3.4 3.4 3.7 3.8 4.3 4.3 4.3 4.3 4.9 4.9 4.9 5.0 5.6 5.6 5.6 5.6 6.4 6.4 6.3 6.4 7.2 7.2 7.2 7.3 TotalPower 892 894 953 962 1085 1084 1082 1092 1229 1228 1226 1236 1385 1384 1382 1392 1560 1559 1557 1566 1764 1763 1761 1771 Capacity 17.9 18.0 18.5 19.3 17.6 17.8 18.3 19.1 17.1 17.4 17.9 18.7 16.3 16.6 17.1 17.9 15.4 15.6 16.2 16.9 14.5 14.8 15.3 16.1 S/T 1.00 0.87 0.73 0.59 1.00 0.88 0.74 0.59 1.00 0.91 0.77 0.62 1.00 1.00 0.79 0.64 1.00 1.00 0.81 0.66 1.00 1.00 0.86 0.71 Evap dT 28 24 21 18 26 24 21 17 26 24 21 18 26 24 21 17 26 24 21 17 27 25 22 18 80 610 PrSuc 127 128 131 136 134 135 138 144 140 142 145 150 146 147 150 156 151 153 156 161 161 162 165 171 PrDis 246 246 248 252 283 284 286 290 323 324 326 330 366 367 369 373 413 414 416 420 466 467 469 473 ODAmps 3.5 3.8 3.8 3.8 4.3 4.3 4.3 4.4 5.0 5.0 4.9 5.0 5.6 5.6 5.6 5.7 6.4 6.4 6.4 6.4 7.3 7.3 7.3 7.3 TotalPower 902 963 961 971 1093 1092 1090 1100 1237 1236 1234 1244 1394 1393 1390 1400 1568 1567 1565 1575 1772 1771 1769 1779 Capacity 18.1 18.3 18.8 19.6 17.9 18.2 18.7 19.5 17.5 17.7 18.2 19.0 16.7 16.9 17.4 18.2 15.7 16.0 16.5 17.3 14.9 15.1 15.6 16.4 S/T 1.00 0.91 0.77 0.63 1.00 0.92 0.78 0.63 1.00 0.95 0.81 0.66 1.00 1.00 0.83 0.68 1.00 1.00 0.85 0.70 1.00 1.00 1.00 0.75 Evap dT 25 23 20 16 25 23 20 16 25 23 20 17 25 23 20 16 25 23 20 16 26 24 21 17 700 PrSuc 129 130 133 139 136 138 141 146 143 144 147 153 148 150 153 158 154 155 158 164 163 165 168 173 PrDis 247 248 250 254 286 287 288 293 326 327 328 333 369 370 371 376 415 416 418 422 468 469 471 475 ODAmps 3.8 3.8 3.8 3.8 4.4 4.4 4.3 4.4 5.0 5.0 5.0 5.0 5.7 5.7 5.7 5.7 6.4 6.4 6.4 6.5 7.3 7.3 7.3 7.3 TotalPower 971 970 967 977 1100 1099 1097 1107 1244 1243 1241 1251 1400 1399 1397 1407 1575 1574 1571 1581 1779 1778 1776 1786 Capacity 17.9 18.2 18.5 19.3 17.6 17.8 18.4 19.2 17.1 17.4 17.9 18.7 16.4 16.6 17.1 17.9 15.4 15.7 16.2 17.0 14.5 14.8 15.3 16.1 S/T 1.00 0.89 0.76 0.61 1.00 0.91 0.77 0.62 1.00 1.00 0.79 0.65 1.00 1.00 0.81 0.67 1.00 1.00 0.84 0.69 1.00 1.00 1.00 0.74 Evap dT 33 31 26 22 31 29 26 22 31 29 26 23 31 29 26 22 31 29 25 22 32 30 27 23 520 PrSuc 127 129 130 136 133 135 138 143 140 141 145 150 145 147 150 155 151 152 156 161 160 162 165 170 PrDis 245 246 246 251 282 283 285 289 322 323 325 329 365 366 368 372 411 412 414 418 464 466 467 471 ODAmps 3.4 3.4 3.7 3.8 4.3 4.3 4.3 4.3 4.9 4.9 4.9 5.0 5.6 5.6 5.6 5.6 6.4 6.4 6.4 6.4 7.3 7.3 7.2 7.3 TotalPower 894 896 955 965 1087 1086 1084 1094 1232 1231 1228 1238 1388 1387 1385 1394 1562 1561 1559 1569 1767 1766 1764 1773 Capacity 18.2 18.3 18.8 19.6 17.9 18.1 18.6 19.4 17.4 17.7 18.2 19.0 16.6 16.9 17.4 18.2 15.7 15.9 16.4 17.2 14.8 15.1 15.6 16.4 S/T 1.00 0.98 0.84 0.69 1.00 1.00 0.85 0.70 1.00 1.00 0.87 0.72 1.00 1.00 0.89 0.74 1.00 1.00 0.91 0.77 1.00 1.00 1.00 0.82 Evap dT 32 28 24 21 30 28 24 21 30 28 25 21 30 28 24 21 29 27 24 21 30 29 25 22 85 610 PrSuc 129 129 133 138 135 137 140 145 142 144 147 152 148 149 152 158 153 155 158 163 162 164 167 173 PrDis 248 247 249 253 284 285 287 291 324 325 327 331 367 368 370 374 414 415 417 421 467 468 470 474 ODAmps 3.5 3.8 3.8 3.8 4.3 4.3 4.3 4.4 5.0 5.0 5.0 5.0 5.6 5.6 5.6 5.7 6.4 6.4 6.4 6.4 7.3 7.3 7.3 7.3 TotalPower 904 965 963 973 1096 1095 1092 1102 1240 1239 1237 1247 1396 1395 1393 1403 1570 1569 1567 1577 1775 1774 1772 1782 Capacity 18.4 18.6 19.1 19.9 18.2 18.5 19.0 19.8 17.8 18.0 18.5 19.3 17.0 17.2 17.7 18.5 16.0 16.3 16.8 17.6 15.1 15.4 15.9 16.7 S/T 1.00 1.00 0.88 0.73 1.00 1.00 0.88 0.74 1.00 1.00 0.91 0.76 1.00 1.00 0.93 0.78 1.00 1.00 1.00 0.81 1.00 1.00 1.00 0.86 Evap dT 28 27 23 20 28 27 23 20 29 27 24 20 28 27 23 20 28 26 23 20 29 28 24 21 700 PrSuc 130 132 135 140 138 139 143 148 145 146 149 154 150 152 155 160 156 157 160 166 165 166 170 175 PrDis 248 250 251 255 287 288 289 294 327 328 329 334 370 371 373 377 416 417 419 423 469 470 472 476 ODAmps 3.8 3.8 3.8 3.8 4.4 4.4 4.4 4.4 5.0 5.0 5.0 5.0 5.7 5.7 5.7 5.7 6.4 6.4 6.4 6.5 7.3 7.3 7.3 7.4 TotalPower, 973 972 970 980 1102 1101 1099 1109 1247 1246 1243 1253 1403 1402 1399 1409 1577 1576 1574 1584 1782 1781 1778 1788 IDB*: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. Shaded area reflects AHRI conditions. Airflow may vary depending on actual ambient conditions and system operation modes. kW = Total system power Amps = outdoor unit amps k n OUTDOOR AMBIENT TEMPERATURE 65"F 75"F 85"F I 95"F 105'F 115"F ENTERING INDOOR WET BULB TEMPERATURE D: Capacity 22.6 24.1 24.2 - 22.9 23.3 24.0 - 22.3 22.7 23.3 - 21.3 21.6 22.3 - 20.0 20.3 21.0 - 18.4 18.7 19.4 - S/T 0.60 0.52 0.37 0.59 0.52 0.38 0.62 0.54 0.41 0.64 0.56 0.43 1.00 0.58 0.45 1.00 0.65 0.51 Evap dT 20 19 15 20 18 15 20 18 15 20 18 15 19 18 14 21 19 16 680 PrSuc 122 123 124 127 128 131 133 135 138 139 140 143 144 145 148 154 155 158 PrDis 256 260 263 302 303 305 345 346 348 391 392 394 441 442 444 486 487 489 ODAmps 4.8 5.1 5.3 6.1 6.1 6.1 7.0 7.0 7.0 8.0 8.0 8.0 9.1 9.1 9.1 9.3 9.3 9.3 TotalPower 1,253 1,347 1,381 1,574 1,572 1,569 1,783 1,782 1,778 2,010 2,008 2,005 2,263 2,261 2,258 2305 2303 2300 Capacity 24.1 23.8 24.5 23.3 23.6 24.3 22.7 23.0 23.7 21.7 22.0 22.7 20.4 20.7 21.4 18.8 19.1 19.8 S/T 0.67 0.59 0.45 0.67 0.59 0.46 0.70 0.62 0.48 0.71 0.64 0.50 1.00 0.66 0.53 1.00 0.72 0.59 Evap dT 19 17 13 18 17 13 19 17 13 18 16 13 18 16 13 20 18 15 70 800 PrSuc 123 123 126 129 130 133 135 137 140 141 142 145 146 147 151 156 157 161 PrDis 262 264 266 304 306 307 348 349 351 394 395 397 444 445 447 488 489 491 ODAm ps 5.2 S.3 S.3 6.1 6.1 6.1 7.1 7.0 7.0 8.0 8.0 8.0 9.1 9.1 9.1 9.4 9.4 9.4 TotalPower 1360 1397 1394 1586 1585 1581 1795 1794 1791 2022 2020 2017 2275 2273 2270 2315 2314 2311 Capacity 24.0 24.3 25.0 23.7 24.1 24.8 23.1 23.5 24.2 22.1 22.4 23.1 20.8 21.1 21.8 19.2 19.5 20.2 S/T 0.70 0.63 0.49 0.71 0.63 0.50 0.73 0.66 0.52 0.75 0.68 0.54 1.00 0.70 0.56 1.00 0.76 0.63 Evap dT 17 15 12 17 15 12 17 16 12 17 15 12 17 15 12 19 17 13 920 PrSuc 124 125 129 131 133 136 138 139 142 143 145 148 148 150 153 158 160 163 PrDis 266 267 269 307 308 310 350 351 353 397 398 400 447 448 450 491 492 494 ODAmps 5.4 5.4 5.3 6.2 6.2 6.2 7.1 7.1 7.1 8.1 8.1 8.1 9.2 9.2 9.2 9.4 9.4 9.4 TotalPower 1408 1407 1403 1596 1594 1591 1805 1803 1800 2031 2030 2027 2285 2283 2280 2324 2323 2320 Capacity 22.6 24.1 24.2 25.2 22.9 23.3 24.0 25.0 22.3 22.7 23.4 24.4 21.3 21.6 22.3 23.4 20.0 20.4 21.0 22.1 18.4 18.8 19.4 20.5 S/T 0.73 0.65 0.50 0.36 0.72 0.64 0.51 0.37 1.00 0.67 0.53 0.39 1.00 0.69 0.55 0.41 1.00 0.71 0.58 0.43 1.00 1.00 0.64 0.50 Evap dT 25 23 19 15 24 22 18 15 24 22 19 15 24 22 18 15 23 22 18 15 25 23 20 16 680 PrSuc 122 123 124 129 127 128 131 136 133 135 138 143 139 140 143 148 144 145 148 154 154 155 158 164 PrDis 256 260 264 268 302 303 305 309 345 346 348 353 391 393 394 399 442 443 445 449 486 487 489 493 ODAmps 4.8 5.1 5.2 5.3 6.1 6.1 6.1 6.1 7.0 7.0 7.0 7.0 8.0 8.0 8.0 8.0 9.1 9.1 9.1 9.1 9.3 9.3 9.3 9.4 TotalPower 1252 1346 1380 1395 1572 1571 1568 1582 1782 1780 1777 1791 2008 2007 2004 2018 2261 2260 2257 2271 2304 2302 2299 2312 Capacity 24.1 23.8 24.5 25.6 23.3 23.6 24.3 25.4 22.7 23.0 23.7 24.8 21.7 22.0 22.7 23.7 20.4 20.7 21.4 22.5 18.8 19.1 19.8 20.8 S/T 0.80 0.72 0.58 0.44 0.80 0.72 0.59 0.45 1.00 0.75 0.61 0.47 1.00 0.77 0.63 0.49 1.00 0.79 0.65 0.51 1.00 1.00 0.72 0.57 Evap dT 23 21 17 14 22 20 17 14 23 21 17 14 22 20 17 14 22 20 17 13 24 22 19 15 75 800 PrSuc 123 123 126 131 129 130 133 139 135 137 140 145 141 142 145 150 146 148 151 156 156 157 161 166 PrDis 262 265 266 271 305 306 308 312 348 349 351 355 394 395 397 402 444 445 447 452 489 490 491 496 ODAmps 5.2 5.3 5.3 5.4 6.1 6.1 6.1 6.2 7.0 7.0 7.0 7.1 8.0 8.0 8.0 8.1 9.1 9.1 9.1 9.2 9.4 9.4 9.4 9.4 TotalPower 1358 1396 1393 1407 1585 1583 1580 1594 1794 1793 1789 1804 2021 2019 2016 2030 2274 2272 2269 2283 2314 2313 2310 2323 Capacity 24.0 24.3 25.0 26.0 23.8 24.1 24.8 25.8 23.2 23.5 24.2 25.2 22.1 22.4 23.1 24.2 20.8 21.2 21.9 22.9 19.2 19.6 20.2 21.3 S/T 0.83 0.75 0.62 0.48 0.84 0.76 0.63 0.48 1.00 0.79 0.65 0.51 1.00 0.81 0.67 0.53 1.00 0.83 0.69 0.55 1.00 1.00 0.76 0.61 Evap dT 21 19 16 13 21 19 16 13 21 20 16 13 21 19 16 13 21 19 16 12 23 21 18 14 920 PrSuc 124 126 129 134 131 133 136 141 138 139 142 147 143 145 148 153 148 150 153 158 158 160 163 168 PrDis 266 267 269 274 307 308 310 315 350 351 353 358 397 398 400 404 447 448 450 454 491 492 494 498 ODAmps 5.4 5.4 5.3 5.4 6.2 6.2 6.2 6.2 7.1 7.1 7.1 7.1 8.1 8.1 8.1 8.1 9.2 9.2 9.2 9.2 9.4 9.4 9.4 9.4 TotalPower 1407 1405 1402 1417 1594 1593 1590 1604 1804 1802 1799 1813 2030 2029 2026 2040 2283 2282 2279 2293 2323 2322 2319 2332 IDB*: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. Shaded area reflects ACCA (TVA) Airflow may vary depending on actual ambient conditions and system operation modes. kW =Total system power Amps = outdoor unit amps k Q 77 0 3 0 0 91 OUTDOOR AMBIENT TEMPERATURE 65*F 75*F 85*F I 95*F 305*F 115*F ENTERING INDOOR WET BULB TEMPERATURE ): Capacity 22.8 24.2 24.3 25.4 23.1 23.4 24.1 25.1 22.5 22.8 23.5 24.5 21.4 21.7 22.4 23.5 20.1 20.5 21.2 22.2 18.6 18.9 19.6 20.6 S/T 1.00 0.77 0.63 0.49 1.00 0.77 0.63 0.49 1.00 0.79 0.66 0.52 1.00 0.81 0.68 0.54 1.00 1.00 0.70 0.56 1.00 1.00 0.77 0.62 Evap dT 29 27 23 19 28 26 22 19 28 26 23 19 28 26 22 19 27 26 22 19 29 28 24 21 680 PrSuc 123 123 125 130 127 129 132 137 134 135 138 143 139 141 144 149 144 146 149 154 154 156 159 164 PrDis 256 261 264 269 302 303 305 310 345 347 348 353 392 393 395 399 442 443 445 450 486 487 489 494 ODAmps 4.8 5.1 5.3 5.3 6.1 6.1 6.1 6.1 7.0 7.0 7.0 7.0 8.0 8.0 8.0 8.0 9.1 9.1 9.1 9.1 9.3 9.3 9.3 9.4 TotalPower 1253 1347 1381 1396 1573 1572 1569 1583 1783 1781 1778 1792 2009 2008 2005 2019 2262 2261 2258 2272 2304 2303 2300 2313 Capacity 24.3 24.0 24.7 25.7 23.4 23.8 24.5 25.5 22.8 23.2 23.8 24.9 21.8 22.1 22.8 23.9 20.5 20.8 21.5 22.6 18.9 19.2 19.9 20.9 S/T 1.00 0.84 0.71 0.56 1.00 0.85 0.71 0.57 1.00 0.87 0.74 0.60 1.00 0.89 0.76 0.61 1.00 1.00 0.78 0.64 1.00 1.00 0.84 0.70 Evap dT 28 24 21 18 26 24 21 18 26 25 21 18 26 24 21 18 26 24 21 17 28 26 23 19 80 800 PrSuc 124 124 127 132 129 131 134 139 136 137 140 146 141 143 146 151 147 148 151 156 156 158 161 166 PrDis 262 265 267 271 305 306 308 313 348 349 351 356 395 396 398 402 445 446 448 452 489 490 492 496 ODAm ps 5.2 5.3 5.3 5.4 6.1 6.1 6.1 6.2 7.1 7.0 7.0 7.1 8.0 8.0 8.0 8.1 9.1 9.1 9.1 9.2 9.4 9.4 9.4 9.4 TotalPower 1359 1397 1394 1408 1586 1584 1581 1595 1795 1794 1790 1805 2022 2020 2017 2031 2275 2273 2270 2284 2315 2314 2311 2324 Capacity 24.1 24.4 25.1 26.2 23.9 24.2 24.9 26.0 23.3 23.6 24.3 25.4 22.2 22.6 23.2 24.3 21.0 21.3 22.0 23.0 19.3 19.7 20.3 21.4 S/T 1.00 0.88 0.74 0.60 1.00 0.89 0.75 0.61 1.00 0.91 0.78 0.63 1.00 0.93 0.79 0.65 1.00 1.00 0.82 0.67 1.00 1.00 0.88 0.74 Evap dT 25 23 20 17 25 23 20 17 25 24 20 17 25 23 20 17 25 23 20 16 27 25 22 18 920 PrSuc 125 126 129 134 132 133 136 141 138 140 143 148 144 145 148 153 149 150 153 159 159 160 164 169 PrDis 266 268 269 274 308 309 311 315 351 352 354 358 397 398 400 405 447 448 450 455 492 493 494 499 ODAmps 5.4 5.4 5.3 5.4 6.2 6.2 6.2 6.2 7.1 7.1 7.1 7.1 8.1 8.1 8.1 8.1 9.2 9.2 9.2 9.2 9.4 9.4 9.4 9.5 TotalPower 1408 1406 1403 1418 1595 1594 1591 1605 1805 1803 1800 1814 2031 2030 2027 2041 2284 2283 2280 2294 2324 2322 2320 2332 Capacity 23.1 24.6 24.7 25.7 23.5 23.8 24.5 25.5 22.8 23.2 23.9 24.9 21.8 22.1 22.8 23.9 20.5 20.9 21.6 22.6 18.9 19.3 19.9 21.0 S/T 1.00 0.87 0.73 0.59 1.00 0.87 0.74 0.59 1.00 1.00 0.76 0.62 1.00 1.00 0.78 0.64 1.00 1.00 0.80 0.66 1.00 1.00 1.00 0.73 Evap dT 32 31 26 23 31 29 26 23 31 30 26 23 31 29 26 22 31 29 26 22 33 31 28 24 680 PrSuc 124 125 126 131 129 131 134 139 136 137 140 145 141 142 145 151 146 148 151 156 156 158 161 166 PrDis 258 262 265 270 304 305 307 311 347 348 350 354 393 394 396 401 443 444 446 451 488 489 491 495 ODAmps 4.8 5.1 5.3 5.3 6.1 6.1 6.1 6.1 7.0 7.0 7.0 7.1 8.0 8.0 8.0 8.0 9.1 9.1 9.1 9.1 9.3 9.3 9.3 9.4 TotalPower 1256 1350 1385 1399 1577 1576 1572 1587 1786 1785 1782 1796 2013 2011 2008 2023 2266 2264 2261 2276 2308 2306 2303 2316 Capacity 24.7 24.4 25.1 26.1 23.8 24.2 24.8 25.9 23.2 23.5 24.2 25.3 22.2 22.5 23.2 24.3 20.9 21.2 21.9 23.0 19.3 19.6 20.3 21.3 S/T 1.00 0.94 0.81 0.67 1.00 0.95 0.81 0.67 1.00 1.00 0.84 0.70 1.00 1.00 0.86 0.72 1.00 1.00 0.88 0.74 1.00 1.00 1.00 0.80 Evap dT 31 28 25 21 30 28 25 21 30 28 25 21 30 28 25 21 30 28 24 21 32 30 26 23 85 800 PrSuc 126 125 129 134 131 133 136 141 138 139 142 147 143 145 148 153 148 150 153 158 158 160 163 168 PrDis 264 266 268 273 306 307 309 314 349 351 352 357 396 397 399 403 446 447 449 454 490 491 493 498 ODAm ps 5.2 5.3 5.3 5.4 6.2 6.2 6.1 6.2 7.1 7.1 7.0 7.1 8.1 8.0 8.0 8.1 9.2 9.1 9.1 9.2 9.4 9.4 9.4 9.4 TotalPower 1363 1400 1397 1411 1589 1588 1585 1599 1799 1797 1794 1808 2025 2024 2021 2035 2278 2277 2274 2288 2318 2317 2314 2327 Capacity 24.5 24.8 25.5 26.6 24.3 24.6 25.3 26.3 23.7 24.0 24.7 25.7 22.6 22.9 23.6 24.7 21.3 21.7 22.4 23.4 19.7 20.1 20.7 21.8 S/T 1.00 0.98 0.85 0.70 1.00 0.99 0.85 0.71 1.00 1.00 0.88 0.73 1.00 1.00 0.90 0.75 1.00 1.00 0.92 0.78 1.00 1.00 1.00 0.84 Evap dT 29 27 24 20 29 27 24 20 29 27 24 20 29 27 24 20 28 27 23 20 31 29 25 22 920 PrSuc 126 128 131 136 134 135 138 143 140 142 145 150 145 147 150 155 151 152 155 160 161 162 165 171 PrDis 268 269 271 275 309 310 312 316 352 353 355 360 398 400 401 406 449 450 452 456 493 494 496 500 ODAmps 5.4 5.4 5.4 5.4 6.2 6.2 6.2 6.2 7.1 7.1 7.1 7.2 8.1 8.1 8.1 8.1 9.2 9.2 9.2 9.2 9.4 9.4 9.4 9.5 TotalPower 1411 1410 1407 1421 1599 1597 1594 1609 1808 1807 1804 1818 2035 2033 2030 2044 2288 2286 2283 2298 2327 2326 2323 2336 IDB*: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. Shaded area reflects AHRI conditions. kW =Total system power Airflow may vary depending on actual ambient conditions and system operation modes. Amps = outdoor unit amps k z m 0 n 0 O r- z OUTDOOR AMBIENT TEMPERATURE 65"F 75"F 85"F I 95"F 105"F 115'F D: ENTERING INDOOR WET BULB TEMPERATURE Capacity 26.8 28.5 30.1 - 28.6 29.0 29.8 - 27.8 28.2 29.1 - 26.5 26.9 27.8 - 24.9 25.3 26.2 - 23.5 23.9 24.8 - S/T 0.62 0.53 0.39 0.62 0.54 0.40 0.64 0.57 0.43 0.66 0.59 0.45 1.00 0.61 0.47 1.00 0.66 0.52 Evap dT 20 19 14 19 17 14 19 18 14 19 17 14 19 17 14 20 18 15 860 PrSuc 126 127 126 128 130 133 135 136 139 140 142 145 146 147 150 152 154 157 PrDis 264 268 271 311 312 314 355 356 358 403 404 406 455 456 458 510 511 513 C DAmps 6.0 6.4 7.0 8.1 8.1 8.1 9.3 9.3 9.2 10.6 10.5 10.5 12.0 12.0 12.0 13.7 13.7 13.7 TotalPower 1562 1677 1,824 2,076 2,074 2,069 2,349 2,347 2,343 2,645 2,643 2,639 2,976 2,974 2,970 3364 3362 3358 Capacity 28.6 29.7 30.6 29.0 29.4 30.3 28.3 28.7 29.5 27.0 27.4 28.2 25.4 25.8 26.7 23.9 24.3 25.2 S/T 0.69 0.61 0.47 0.70 0.62 0.48 0.72 0.64 0.50 0.74 0.66 0.52 1.00 0.69 0.55 1.00 0.74 0.60 Evap dT 19 16 13 18 16 13 18 16 13 18 16 13 18 16 13 19 17 14 70 1010 PrSuc 128 125 128 130 132 135 137 138 142 142 144 147 148 149 152 154 156 159 PrDis 270 272 274 313 315 317 358 359 361 406 407 409 457 459 460 512 514 515 ODAm ps 6.5 7.1 7.1 8.1 8.1 8.1 9.3 9.3 9.3 10.6 10.6 10.6 12.1 12.1 12.0 13.7 13.7 13.7 TotalPower 1694 1844 1840 2091 2089 2085 2365 2363 2358 2661 2659 2654 2991 2989 2985 3379 3378 3373 Capacity 29.8 30.2 31.1 29.6 30.0 30.8 28.8 29.2 30.1 27.5 27.9 28.8 25.9 26.3 27.2 24.5 24.9 25.7 S/T 0.73 0.65 0.51 0.73 0.66 0.52 0.76 0.68 0.54 1.00 0.70 0.56 1.00 0.72 0.58 1.00 0.78 0.64 Evap dT 17 15 12 17 15 12 17 15 12 17 15 12 17 15 12 18 16 13 1160 PrSuc 125 127 130 133 134 137 139 141 144 145 146 149 150 152 155 157 158 161 PrDis 274 275 277 316 317 319 360 362 364 408 410 411 460 461 463 515 516 518 ODAm ps 7.1 7.1 7.1 8.2 8.2 8.2 9.4 9.4 9.4 10.7 10.7 10.6 12.1 12.1 12.1 13.8 13.8 13.8 TotalPower 1858 1856 1852 2103 2101 2097 2377 2375 2371 2673 2671 2667 3004 3002 2998 3392 3390 3386 Capacity 26.8 28.6 30.1 31.4 28.6 29.0 29.9 31.2 27.8 28.2 29.1 30.4 26.5 26.9 27.8 29.1 25.0 25.4 26.2 27.5 23.5 23.9 24.8 26.1 S/T 0.76 0.67 0.53 0.38 0.75 0.67 0.53 0.39 1.00 0.70 0.56 0.41 1.00 0.72 0.58 0.43 1.00 0.74 0.60 0.45 1.00 0.80 0.66 0.51 Evap dT 24 23 18 15 23 21 18 15 23 22 18 15 23 21 18 15 23 21 18 14 24 22 19 15 860 PrSuc 126 127 126 131 128 130 133 138 135 136 139 145 140 142 145 150 146 147 150 155 152 154 157 165 PrDis 264 268 272 276 311 312 314 319 355 357 358 363 403 404 406 411 455 456 458 463 510 511 513 521 ODAm ps 6.0 6.4 7.0 7.1 8.1 8.1 8.0 8.1 9.3 9.3 9.2 9.3 10.5 10.5 10.5 10.6 12.0 12.0 12.0 12.0 13.7 13.7 13.6 13.7 TotalPower 1560 1676 1823 1842 2074 2072 2068 2087 2348 2346 2341 2360 2644 2642 2637 2656 2974 2972 2968 2987 3362 3361 3356 3375 Capacity 28.6 29.7 30.6 31.9 29.0 29.4 30.3 31.6 28.3 28.7 29.6 30.9 27.0 27.4 28.3 29.6 25.4 25.8 26.7 28.0 23.9 24.4 25.2 26.5 S/T 0.83 0.74 0.60 0.46 0.83 0.75 0.61 0.46 1.00 0.78 0.64 0.49 1.00 0.80 0.66 0.51 1.00 0.82 0.68 0.53 1.00 1.00 0.73 0.58 Evap dT 23 20 17 13 22 20 17 13 22 20 17 14 22 20 17 13 22 20 16 13 23 21 18 14 75 1010 PrSuc 128 125 128 133 130 132 135 140 137 138 142 147 142 144 147 152 148 149 152 158 154 156 159 167 PrDis 270 272 274 279 314 315 317 321 358 359 361 366 406 407 409 414 458 459 461 465 513 514 516 524 ODAm ps 6.5 7.1 7.0 7.1 8.1 8.1 8.1 8.2 9.3 9.3 9.3 9.4 10.6 10.6 10.6 10.7 12.1 12.0 12.0 12.1 13.7 13.7 13.7 13.8 TotalPower 1692 1842 1838 1857 2089 2087 2083 2102 2363 2361 2357 2376 2659 2657 2653 2672 2990 2988 2984 3002 3378 3376 3372 3390 Capacity 29.8 30.2 31.1 32.4 29.6 30.0 30.8 32.2 28.8 29.2 30.1 31.4 27.5 27.9 28.8 30.1 25.9 26.3 27.2 28.5 24.5 24.9 25.8 27.1 S/T 0.86 0.78 0.64 0.49 0.87 0.79 0.65 0.50 1.00 0.82 0.67 0.53 1.00 0.84 0.69 0.55 1.00 0.86 0.72 0.57 1.00 1.00 0.77 0.62 Evap dT 21 19 16 12 21 19 16 12 21 19 16 13 21 19 16 12 20 19 15 12 22 20 17 13 1160 PrSuc 125 127 130 135 133 134 137 143 139 141 144 149 145 146 149 154 150 152 155 160 157 158 161 169 PrDis 274 275 277 282 316 317 319 324 361 362 364 368 409 410 412 416 460 461 463 468 515 516 518 526 0 DAmps 7.1 7.1 7.1 7.2 8.2 8.2 8.2 8.2 9.4 9.4 9.4 9.4 10.7 10.7 10.6 10.7 12.1 12.1 12.1 12.2 13.8 13.8 13.8 13.8 TotalPower 1857 1855 1850 1869 2102 2100 2096 2114 2375 2373 2369 2388 2671 2669 2665 2684 3002 3000 2996 3015 3390 3388 3384 3403 IDB*: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. Shaded area reflects ACCA (TVA) Airflow may vary depending on actual ambient conditions and system operation modes. kW =Total system power Amps = outdoor unit amps x z m n O O r_ z C) ZD N F-� V w O N W O T m n n H IN Q fl, 77 0 3 0 0 0 91 OUTDOOR AMBIENT TEMPERATURE 657 75°F 85°F I 95°F 105°F 115°F D: ENTERING INDOOR WET BULB TEMPERATURE Capacity 27.0 28.7 30.3 31.6 28.7 29.2 30.0 31.3 28.0 28.4 29.3 30.6 26.7 27.1 28.0 29.3 2S.1 25.5 26.4 27.7 23.7 24.1 24.9 26.2 S/T 1.00 0.80 0.66 0.51 1.00 0.80 0.66 0.52 1.00 0.83 0.69 0.54 1.00 0.85 0.71 D.S6 1.00 1.00 0.73 D.S8 1.00 1.00 0.79 0.64 Evap dT 28 27 22 19 27 25 22 19 27 25 22 19 27 25 22 18 27 25 22 18 28 26 23 19 860 PrSuc 127 127 126 131 129 130 134 139 135 137 140 145 141 142 145 151 146 148 151 156 153 154 158 165 PrDis 265 269 272 277 311 313 315 319 356 357 359 364 404 405 407 412 455 457 458 463 510 512 513 522 ODAm ps 6.0 6.4 7.0 7.1 8.1 8.1 8.0 8.1 9.3 9.3 9.2 9.3 10.6 10.5 10.5 10.6 12.0 12.0 12.0 12.0 13.7 13.7 13.7 13.7 TotalPower 1562 1677 1824 1843 2075 2073 2069 2088 2349 2347 2343 2361 2645 2643 2639 2658 2976 2974 2970 2988 3364 3362 3358 3376 Capacity 28.7 29.9 30.7 32.0 29.2 29.6 30.5 31.8 28.4 28.8 29.7 31.0 27.1 27.5 28.4 29.7 25.5 26.0 26.8 28.1 24.1 24.5 25.4 26.7 S/T 1.00 0.87 0.73 0.59 1.00 0.88 0.74 0.59 1.00 0.91 0.77 0.62 1.00 0.93 0.79 0.64 1.00 1.00 0.81 0.66 1.00 1.00 0.86 0.71 Evap dT 27 24 21 17 26 24 21 17 26 24 21 17 26 24 21 17 25 24 20 17 27 25 21 18 80 1010 PrSuc 128 125 128 133 131 133 136 141 137 139 142 147 143 144 148 153 148 150 153 158 155 157 160 167 PrDis 270 273 275 280 314 315 317 322 359 360 362 366 406 408 410 414 458 459 461 466 513 514 516 524 ODAm ps 6.5 7.1 7.1 7.1 8.1 8.1 8.1 8.2 9.3 9.3 9.3 9.4 10.6 10.6 10.6 10.7 12.1 12.0 12.0 12.1 13.7 13.7 13.7 13.8 TotalPower 1693 1844 1839 1858 2091 2089 2085 2103 2364 2362 2358 2377 2660 2658 2654 2673 2991 2989 2985 3004 3379 3377 3373 3392 Capacity 30.0 30.4 31.3 32.6 29.7 30.1 31.0 32.3 29.0 29.4 30.2 31.6 27.7 28.1 28.9 30.3 26.1 26.5 27.4 28.7 24.6 25.0 25.9 27.2 S/T 1.00 0.91 0.77 0.62 1.00 0.92 0.78 0.63 1.00 0.95 0.80 0.66 1.00 1.00 0.82 0.68 1.00 1.00 0.85 0.70 1.00 1.00 0.90 0.75 Evap dT 25 23 20 16 25 23 20 16 25 23 20 16 25 23 20 16 24 23 19 16 25 24 20 17 1160 PrSuc 126 127 131 136 133 135 138 143 140 141 144 150 145 147 150 155 151 152 155 160 157 159 162 170 PrDis 274 276 277 282 317 318 320 325 361 362 364 369 409 410 412 417 461 462 464 468 516 517 519 527 C DAmps 7.1 7.1 7.1 7.2 8.2 8.2 8.2 8.3 9.4 9.4 9.4 9.4 10.7 10.7 10.6 10.7 12.1 12.1 12.1 12.2 13.8 13.8 13.8 13.9 TotalPower 1858 1856 1852 1870 2103 2101 2097 2116 2377 2375 2370 2389 2673 2671 2666 2685 3003 3001 2997 3016 3391 3389 3385 3404 Capacity 27.4 29.2 30.8 32.1 29.2 29.6 30.5 31.8 28.5 28.9 29.7 31.1 27.2 27.6 28.4 29.8 25.6 26.0 26.9 28.2 24.1 24.6 25.4 26.7 S/T 1.00 0.90 0.76 0.61 1.00 0.91 0.77 0.62 1.00 1.00 0.79 0.65 1.00 1.00 0.81 0.67 1.00 1.00 0.84 0.69 1.00 1.00 1.00 0.74 Evap dT 32 30 25 22 30 29 25 22 31 29 26 22 30 29 25 22 30 28 25 22 31 29 26 23 860 PrSuc 129 129 128 133 131 132 135 140 137 139 142 147 143 144 147 152 148 150 153 158 155 156 159 167 PrDis 266 270 273 278 313 314 316 320 357 358 360 365 405 406 408 413 457 458 460 464 512 513 515 523 ODAm ps 6.0 6.5 7.0 7.1 8.1 8.1 8.1 8.2 9.3 9.3 9.3 9.3 10.6 10.6 10.5 10.6 12.0 12.0 12.0 12.1 13.7 13.7 13.7 13.8 TotalPower 1565 1681 1829 1848 2080 2078 2074 2093 2354 2352 2347 2366 2650 2648 2643 2662 2980 2978 2974 2993 3368 3366 3362 3381 Capacity 29.2 30.3 31.2 32.5 29.7 30.1 30.9 32.3 28.9 29.3 30.2 31.5 27.6 28.0 28.9 30.2 26.0 26.4 27.3 28.6 24.6 25.0 25.9 27.2 S/T 1.00 0.98 0.84 0.69 1.00 0.99 0.85 0.70 1.00 1.00 0.87 0.72 1.00 1.00 0.89 0.74 1.00 1.00 0.91 0.77 1.00 1.00 1.00 0.82 Evap dT 31 27 24 21 29 27 24 21 29 28 24 21 29 27 24 21 29 27 24 20 30 28 25 22 85 1010 PrSuc 130 127 130 135 133 134 137 143 139 141 144 149 145 146 149 155 150 152 155 160 157 158 161 169 PrDis 272 274 276 281 315 317 319 323 360 361 363 368 408 409 411 416 459 461 462 467 514 516 517 526 ODAm ps 6.5 7.1 7.1 7.2 8.2 8.2 8.1 8.2 9.4 9.3 9.3 9.4 10.6 10.6 10.6 10.7 12.1 12.1 12.1 12.1 13.8 13.8 13.7 13.8 TotalPower 1698 1848 1844 1863 2095 2093 2089 2108 2369 2367 2363 2382 2665 2663 2659 2678 2996 2994 2990 3008 3384 3382 3378 3396 Capacity 30.5 30.9 31.7 33.1 30.2 30.6 31.5 32.8 29.5 29.9 30.7 32.0 28.2 28.6 29.4 30.7 26.6 27.0 27.8 29.2 25.1 25.5 26.4 27.7 S/T 1.00 1.00 0.88 0.73 1.00 1.00 0.88 0.74 1.00 1.00 0.91 0.76 1.00 1.00 0.93 0.78 1.00 1.00 0.95 0.80 1.00 1.00 1.00 0.86 Evap dT 28 26 23 20 28 26 23 20 28 27 23 20 28 26 23 20 28 26 23 19 29 27 24 20 1160 PrSuc 128 129 132 138 13S 137 140 145 142 143 146 151 147 149 152 157 152 154 157 162 159 161 164 172 PrDis 276 277 279 283 318 319 321 326 362 364 366 370 410 412 413 418 462 463 465 470 517 518 520 528 0 DAmps 7.2 7.1 7.1 7.2 8.2 8.2 8.2 8.3 9.4 9.4 9.4 9.5 10.7 10.7 10.7 10.7 12.1 12.1 12.1 12.2 13.8 13.8 13.8 13.9 TotalPower 1863 1861 1856 1875 2108 2106 2101 2120 2381 2379 2375 2394 2677 2675 2671 2690 3008 3006 3002 3021 3396 3394 3390 3409 IDB*: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. Shaded area reflects AHRI conditions Airflow may vary depending on actual ambient conditions and system operation modes. kW =Total system power Amps = outdoor unit amps k Z 0 rn, n O O r- Z Gl 51, OUTDOOR AMBIENT TEMPERATURE 65*F 75*F 85*F I 95*F 305*F 115°F ENTERING INDOOR WET BULB TEMPERATURE D: Capacity 32.5 34.4 36.2 - 34.4 34.9 35.9 - 33.5 34.0 35.0 - 31.9 32.4 33.5 - 30.0 30.5 31.5 - 27.6 28.1 29.1 - S/T 0.63 0.55 0.40 0.63 0.55 0.40 0.65 0.57 0.43 0.67 0.59 0.45 1.00 0.62 0.47 1.00 0.68 0.54 Evap dT 20 18 14 19 17 14 19 17 14 19 17 14 18 17 14 21 19 16 1070 PrSuc 126 127 125 128 129 132 134 136 139 140 141 144 145 146 149 159 160 163 PrDis 264 267 268 307 308 310 351 352 354 398 399 401 449 450 452 505 506 508 ODAmps 7.9 8.3 9.4 10.9 10.9 10.9 12.5 12.5 12.5 14.3 14.3 14.3 16.3 16.3 16.2 16.3 16.3 16.3 TotalPower 2,124 2,250 2,539 2,884 2,881 2,875 3,259 3,256 3,250 3,664 3,662 3,656 4,118 4,115 4,109 4091 4089 4084 Capacity 34.5 35.7 36.8 34.9 35.4 36.5 34.0 34.5 35.6 32.5 33.0 34.0 30.6 31.1 32.1 28.2 28.6 29.7 S/T 0.71 0.62 0.48 0.71 0.63 0.49 0.74 0.66 0.51 0.76 0.68 0.53 1.00 0.70 0.56 1.00 0.76 0.62 Evap dT 19 16 13 17 16 13 18 16 13 17 16 13 17 15 12 20 18 14 70 1260 PrSuc 128 124 127 130 131 134 136 138 141 142 143 146 147 149 152 161 162 165 PrDis 268 269 271 310 311 313 354 355 357 401 402 404 452 453 455 507 508 510 ODAmps 8.4 9.5 9.5 11.0 11.0 11.0 12.6 12.6 12.6 14.4 14.4 14.4 16.4 16.4 16.3 16.4 16.4 16.4 TotalPower 2271 2567 2561 2905 2903 2897 3280 3278 3272 3686 3683 3678 4139 4137 4131 4110 4108 4103 Capacity 35.9 36.4 37.4 35.6 36.1 37.1 34.7 35.2 36.2 33.1 33.6 34.7 31.2 31.7 32.8 28.8 29.3 30.3 S/T 0.74 0.66 0.52 0.75 0.67 0.53 0.78 0.69 0.55 1.00 0.72 0.57 1.00 0.74 0.60 1.00 1.00 0.66 Evap dT 16 15 12 16 15 12 17 15 12 16 15 11 16 14 11 18 17 13 1450 PrSuc 125 126 129 132 134 137 139 140 143 144 146 149 149 151 154 163 165 168 PrDis 270 272 273 312 313 315 356 357 359 403 405 406 454 456 457 510 511 513 ODAm ps 9.6 9.6 9.6 11.1 11.1 11.0 12.7 12.7 12.7 14.5 14.5 14.4 16.4 16.4 16.4 16.5 16.5 16.5 TotalPower 2587 2584 2578 2923 2920 2914 3297 3295 3289 3703 3701 3695 4156 4154 4148 4125 4123 4118 Capacity 32.5 34.4 36.3 37.8 34.4 34.9 35.9 37.5 33.5 34.0 35.0 36.6 31.9 32.4 33.5 35.1 30.0 30.5 31.6 33.2 27.7 28.1 29.2 29.4 S/T 0.77 0.69 0.53 0.38 0.76 0.68 0.54 0.39 1.00 0.71 0.57 0.42 1.00 0.73 0.59 0.44 1.00 0.75 0.61 0.46 1.00 1.00 0.67 0.52 Evap dT 24 22 18 14 23 21 18 14 23 21 18 15 22 21 18 14 22 21 17 14 25 23 20 16 1070 PrSuc 127 127 125 130 128 129 132 137 134 136 139 144 140 141 144 149 145 146 149 155 159 160 163 170 PrDis 265 267 268 273 307 308 310 315 351 352 354 359 398 399 401 406 449 450 452 457 505 506 508 510 ODAmps 7.9 8.3 9.4 9.5 10.9 10.9 10.9 11.0 12.5 12.5 12.5 12.6 14.3 14.3 14.3 14.4 16.3 16.3 16.2 16.3 16.3 16.3 16.3 15.4 TotalPower 2122 2248 2537 2563 2881 2879 2873 2899 3256 3254 3248 3274 3662 3659 3654 3679 4115 4113 4107 4133 4090 4087 4082 3862 Capacity 34.5 35.8 36.8 38.4 35.0 35.5 36.5 38.1 34.1 34.5 35.6 37.2 32.5 33.0 34.0 35.6 30.6 31.1 32.1 33.7 28.2 28.7 29.7 29.9 S/T 0.85 0.76 0.62 0.46 0.85 0.77 0.62 0.47 1.00 0.79 0.65 0.50 1.00 0.81 0.67 0.52 1.00 0.84 0.69 0.54 1.00 1.00 0.75 0.60 Evap dT 23 20 16 13 21 19 16 13 21 20 17 13 21 19 16 13 21 19 16 13 24 22 18 15 75 1260 PrSuc 128 124 127 132 130 131 134 140 136 138 141 146 142 143 146 151 147 149 152 157 161 162 166 172 PrDis 269 269 271 276 310 311 313 318 354 355 357 361 401 402 404 409 452 453 455 460 507 509 511 513 ODAmps 8.4 9.5 9.5 9.6 11.0 11.0 11.0 11.1 12.6 12.6 12.6 12.7 14.4 14.4 14.4 14.5 16.4 16.3 16.3 16.4 16.4 16.4 16.4 15.5 TotalPower 2269 2565 2559 2585 2903 2901 2895 2921 3278 3276 3270 3296 3684 3681 3676 3701 4137 4135 4129 4155 4108 4106 4101 3880 Capacity 35.9 36.4 37.5 39.1 35.6 36.1 37.2 38.7 34.7 35.2 36.2 37.8 33.2 33.6 34.7 36.3 31.2 31.7 32.8 34.4 28.8 29.3 30.3 30.5 S/T 0.88 0.80 0.66 0.50 0.88 0.80 0.66 0.51 1.00 0.83 0.69 0.54 1.00 0.85 0.71 0.56 1.00 0.87 0.73 0.58 1.00 1.00 0.80 0.64 Evap dT 20 19 15 12 20 18 15 12 20 19 16 12 20 18 15 12 20 18 15 12 22 21 17 14 1450 PrSuc 125 126 129 135 132 134 137 142 139 140 143 148 144 146 149 154 149 151 154 159 163 165 168 174 PrDis 271 272 274 278 313 314 316 320 356 358 359 364 404 405 407 411 455 456 458 462 510 511 513 516 ODAmps 9.6 9.6 9.6 9.7 11.1 11.1 11.0 11.1 12.7 12.7 12.7 12.8 14.5 14.5 14.4 14.5 16.4 16.4 16.4 16.5 16.5 16.5 16.4 15.6 TotalPower 2584 2582 2576 2602 2920 2918 2912 2938 3295 3293 3287 3313 3701 3698 3693 3718 4154 4152 4146 4172 4123 4121 4116 3894 IDB*: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. Shaded area reflects ACCA (TVA) Airflow may vary depending on actual ambient conditions and system operation modes. kW = Total system power Amps = outdoor unit amps x z m n O O r_ z C) sz 77 0 3 0 0 91 OUTDOOR AMBIENT TEMPERATURE 65°F 75°F 85°F I 95°F 105*F 115°F ENTERING INDOOR WET BULB TEMPERATURE ): Capacity 32.7 34.6 36.4 38.0 34.6 35.1 36.1 37.7 33.7 34.2 35.2 36.8 32.1 32.6 33.7 35.2 30.2 30.7 31.7 33.3 27.8 28.3 29.3 29.6 S/T 1.00 0.82 0.67 0.S1 1.00 0.82 0.67 O.S2 1.00 0.84 0.70 0.55 1.00 0.86 0.72 0.57 1.00 1.00 0.74 0.59 1.00 1.00 0.81 0.66 Evap dT 28 26 21 18 26 25 21 18 27 25 22 18 26 25 21 18 26 24 21 18 29 27 24 20 1070 PrSuc 127 128 125 131 128 130 133 138 135 136 139 144 140 142 145 150 145 147 150 155 159 161 164 170 PrDis 265 268 269 273 308 309 311 315 352 353 355 359 399 400 402 406 450 451 453 457 505 506 508 511 ODAmps 7.9 8.3 9.4 9.5 10.9 10.9 10.9 11.0 12.5 12.5 12.5 12.6 14.3 14.3 14.3 14.4 16.3 16.3 16.2 16.3 16.3 16.3 16.3 15.4 TotalPower 2123 2250 2539 2565 2883 2881 2875 2900 3258 3255 3250 3275 3664 3661 3655 3681 4117 4115 4109 4134 4091 4089 4084 3864 Capacity 34.7 35.9 37.0 38.6 35.1 35.6 36.7 38.3 34.2 34.7 35.8 37.4 32.7 33.2 34.2 35.8 30.8 31.3 32.3 33.9 28.4 28.8 29.9 30.1 S/T 1.00 0.89 0.75 0.60 1.00 0.90 0.75 0.60 1.00 0.92 0.78 0.63 1.00 0.94 0.80 0.65 1.00 1.00 0.82 0.67 1.00 1.00 0.89 0.74 Evap dT 27 23 20 17 25 23 20 17 25 24 20 17 25 23 20 17 25 23 20 17 28 26 22 19 80 1260 PrSuc 129 125 128 133 130 132 135 140 137 138 141 147 142 144 147 152 148 149 152 157 161 163 166 172 PrDis 269 270 272 276 310 312 313 318 354 355 357 362 402 403 405 409 453 454 456 460 508 509 511 513 ODAmps 8.4 9.5 9.5 9.6 11.0 11.0 11.0 11.1 12.6 12.6 12.6 12.7 14.4 14.4 14.4 14.5 16.4 16.4 16.3 16.4 16.4 16.4 16.4 15.5 TotalPower 2271 2567 2561 2587 2905 2902 2897 2922 3280 3277 3272 3297 3686 3683 3677 3703 4139 4136 4131 4156 4110 4107 4102 3881 Capacity 36.1 36.6 37.6 39.2 35.8 36.3 37.3 38.9 34.9 35.4 36.4 38.0 33.3 33.8 34.9 36.5 31.4 31.9 33.0 34.5 29.0 29.5 30.5 30.7 S/T 1.00 0.93 0.79 0.64 1.00 0.94 0.79 0.64 1.00 0.96 0.82 0.67 1.00 1.00 0.84 0.69 1.00 1.00 0.86 0.71 1.00 1.00 1.00 0.78 Evap dT 24 22 19 16 24 22 19 16 24 23 19 16 24 22 19 16 24 22 19 16 27 25 21 18 1450 PrSuc 125 127 130 13S 133 134 137 142 139 141 144 149 145 146 149 154 1SO 151 155 160 164 165 169 175 PrDis 271 272 274 279 313 314 316 321 357 358 360 365 404 405 407 412 455 456 458 463 511 512 514 516 ODAmps 9.6 9.6 9.6 9.7 11.1 11.1 11.0 11.2 12.7 12.7 12.7 12.8 14.5 14.5 14.4 14.5 16.4 16.4 16.4 16.5 16.5 16.5 16.5 15.6 TotalPower 2586 2584 2578 2604 2922 2919 2914 2939 3297 3294 3289 3314 3703 3700 3694 3720 4156 4153 4148 4173 4125 4123 4118 3895 Capacity 33.2 35.2 37.0 38.6 35.2 35.7 36.7 38.3 34.3 34.8 35.8 37.4 32.7 33.2 34.2 35.8 30.8 31.3 32.3 33.9 28.4 28.9 29.9 30.1 S/T 1.00 0.93 0.77 0.62 1.00 0.92 0.78 0.63 1.00 1.00 0.81 0.65 1.00 1.00 0.83 0.68 1.00 1.00 0.85 0.70 1.00 1.00 1.00 0.76 Evap dT 32 30 25 21 30 28 25 21 30 28 25 22 30 28 25 21 29 28 25 21 33 31 27 24 1070 PrSuc 129 130 127 132 130 132 135 140 136 138 141 146 142 143 146 152 147 149 152 157 161 163 166 172 PrDis 266 269 270 275 309 310 312 317 353 354 356 360 400 401 403 408 451 452 454 459 507 508 510 512 ODAmps 7.9 8.4 9.4 9.6 10.9 10.9 10.9 11.0 12.6 12.6 12.5 12.6 14.3 14.3 14.3 14.4 16.3 16.3 16.3 16.4 16.4 16.3 16.3 15.5 TotalPower 2129 2255 2545 2571 2890 2887 2881 2907 3265 3262 3256 3282 3670 3668 3662 3688 4124 4121 4115 4141 4097 4094 4089 3869 Capacity 35.2 36.5 37.6 39.2 35.7 36.2 37.3 38.9 34.8 35.3 36.4 37.9 33.3 33.8 34.8 36.4 31.4 31.8 32.9 34.5 28.9 29.4 30.4 30.6 S/T 1.00 1.00 0.85 0.70 1.00 1.00 0.86 0.71 1.00 1.00 0.89 0.74 1.00 1.00 0.91 0.76 1.00 1.00 0.93 0.78 1.00 1.00 1.00 0.84 Evap dT 30 27 23 20 28 27 23 20 29 27 24 20 28 27 23 20 28 26 23 20 31 29 26 22 85 1260 PrSuc 131 126 129 135 132 134 137 142 139 140 143 148 144 146 149 154 149 151 154 159 163 165 168 174 PrDis 270 271 273 277 312 313 315 319 356 357 359 363 403 404 406 410 454 455 457 461 509 510 512 515 ODAmps 8.4 9.6 9.5 9.6 11.0 11.0 11.0 11.1 12.7 12.6 12.6 12.7 14.4 14.4 14.4 14.5 16.4 16.4 16.4 16.5 16.4 16.4 16.4 15.5 TotalPower 2276 2573 2567 2593 2912 2909 2903 2929 3286 3284 3278 3304 3692 3690 3684 3709 4145 4143 4137 4163 4115 4113 4108 3887 Capacity 36.7 37.2 38.2 39.8 36.4 36.9 37.9 39.5 35.5 36.0 37.0 38.6 33.9 34.4 35.S 37.0 32.0 32.5 33.5 3S.1 29.6 30.1 31.1 31.3 S/T 1.00 1.00 0.89 0.74 1.00 1.00 0.90 0.75 1.00 1.00 0.93 0.78 1.00 1.00 0.95 0.80 1.00 1.00 0.97 0.82 1.00 1.00 1.00 0.88 Evap dT 27 26 22 19 27 26 22 19 28 26 23 19 27 26 22 19 27 25 22 19 30 28 25 21 1450 PrSuc 127 129 132 137 135 136 139 144 141 142 146 151 146 148 151 156 152 153 156 161 166 167 170 177 PrDis 272 274 275 280 314 315 317 322 358 359 361 366 405 407 408 413 456 458 459 464 512 513 515 517 ODAmps 9.6 9.6 9.6 9.7 11.1 11.1 11.1 11.2 12.7 12.7 12.7 12.8 14.5 14.5 14.5 14.6 16.5 16.5 16.4 16.5 16.5 16.5 16.5 15.6 TotalPower 2593 2590 2584 2610 2929 2926 2920 2946 3303 3301 3295 3321 3709 3707 3701 3726 4163 4160 4154 4180 4130 4128 4123 3901 IDB*: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. Shaded area reflects AHRI conditions Airflow may vary depending on actual ambient conditions and system operation modes. kW = Total system power Amps = outdoor unit amps k n z rn n 0 O z G1 a OUTDOOR AMBIENT TEMPERATURE 65'F 757E 857E 1 957E 105"F 115"F ENTERING INDOOR WET BULB TEMPERATURE D: Capacity 32.3 40.1 43.2 - 40.2 40.8 42.0 - 39.2 39.8 41.0 - 37.3 37.9 39.1 - 35.1 35.7 36.9 - 32.2 32.8 34.0 - S/T 0.60 0.50 0.37 0.57 0.50 0.37 0.60 0.52 0.39 0.62 0.54 0.41 0.64 0.56 0.43 1.00 0.62 0.49 Evap dT 20 19 15 20 18 15 20 18 15 20 18 15 19 18 14 21 20 16 1120 PrSuc 121 119 121 121 122 125 127 128 131 132 133 136 139 141 144 151 152 155 PrDis 250 265 269 309 310 312 353 354 356 400 401 403 455 456 458 504 505 507 ODAmps 7.5 10.1 10.8 13.9 13.8 13.8 15.9 15.9 15.9 18.1 18.1 18.1 20.6 20.6 20.6 19.7 19.6 19.6 TotalPower 1896 2543 2,721 3,446 3,442 3,435 3,918 3,914 3,907 4,428 4,425 4,418 4,999 4,996 4,988 4741 4738 4732 Capacity 35.5 42.5 43.0 40.9 41.4 42.7 39.8 40.4 41.6 38.0 38.6 39.8 35.7 36.3 37.5 32.8 33.4 34.6 S/T 0.66 0.57 0.44 0.65 0.57 0.44 0.67 0.60 0.47 0.69 0.62 0.49 0.71 0.64 0.51 1.00 0.70 0.56 Evap dT 19 17 13 18 17 13 19 17 13 18 17 13 18 16 13 20 18 15 70 1320 PrSuc 122 120 120 123 124 127 129 130 133 134 135 138 141 143 146 153 154 157 PrDis 259 270 272 311 313 314 356 357 359 403 404 406 457 459 460 507 508 510 ODAm ps 8.5 11.0 12.1 14.0 14.0 13.9 16.0 16.0 16.0 18.2 18.2 18.2 20.7 20.7 20.7 19.8 19.7 19.7 TotalPower 2141 2751 3039 3473 3469 3462 3945 3941 3934 4455 4452 4445 5026 5023 5015 4762 4760 4754 Capacity 40.9 43.4 43.8 41.7 42.2 43.5 40.6 41.2 42.4 38.8 39.4 40.6 36.5 37.1 38.3 33.6 34.1 35.3 S/T 0.69 0.60 0.47 0.68 0.61 0.48 0.71 0.63 0.50 0.73 0.65 0.52 1.00 0.67 0.54 1.00 0.73 0.60 Evap dT 18 16 12 17 15 12 18 16 12 17 15 12 17 15 12 19 17 14 1520 PrSuc 122 123 123 125 127 129 131 133 136 136 138 141 144 145 148 155 156 159 PrDis 269 273 275 314 315 317 358 359 361 406 407 409 460 461 463 509 510 512 ODAmps 10.3 11.0 12.2 14.1 14.1 14.0 16.1 16.1 16.1 18.3 18.3 18.3 20.8 20.8 20.8 19.8 19.8 19.8 TotalPowe 2585 2771 3062 3495 3492 3484 3967 3964 3956 4478 4474 4467 5048 5045 5038 4780 4777 4771 Capacity 32.3 40.1 43.2 44.3 40.3 40.8 42.1 43.9 39.2 39.8 41.0 42.8 37.4 37.9 39.2 41.0 35.1 35.7 36.9 38.8 32.2 32.8 34.0 34.1 S/T 0.73 0.63 0.49 0.35 0.70 0.62 0.49 0.36 0.72 0.65 0.52 0.38 0.74 0.67 0.54 0.40 1.00 0.69 0.56 0.42 1.00 0.75 0.62 0.47 Evap dT 23 23 19 15 24 22 18 15 24 22 19 15 24 22 18 15 23 22 18 15 26 24 20 16 1120 PrSuc 121 119 121 123 121 122 125 130 127 128 131 136 132 133 136 144 139 141 144 149 151 152 155 161 PrDis 250 265 269 274 309 310 312 317 353 354 356 361 401 402 404 411 455 456 458 463 504 505 507 506 ODAmps 7.5 10.1 10.8 12.1 13.8 13.8 13.8 13.9 15.9 15.9 15.8 16.0 18.1 18.1 18.1 18.2 20.6 20.6 20.5 20.7 19.6 19.6 19.6 18.2 TotallPower 1894 2540 2719 3042 3443 3440 3432 3465 3915 3912 3904 3937 4426 4422 4415 4447 4996 4993 4986 5018 4738 4736 4730 4394 Capacity 35.5 42.6 43.0 44.9 40.9 41.5 42.7 44.5 39.8 40.4 41.6 43.5 38.0 38.6 39.8 41.7 35.8 36.3 37.6 39.4 32.8 33.4 34.6 34.7 S/T 0.79 0.69 0.56 0.42 0.77 0.70 0.57 0.43 0.79 0.72 0.59 0.45 1.00 0.74 0.61 0.47 1.00 0.76 0.63 0.49 1.00 0.82 0.69 0.55 Evap dT 23 22 17 14 22 21 17 14 23 21 17 14 22 20 17 14 22 20 17 13 24 22 19 15 75 1320 PrSuc 122 120 120 125 123 124 127 132 129 130 133 138 134 135 138 146 141 143 146 151 153 154 157 163 PrDis 259 270 273 277 312 313 315 319 356 357 359 363 403 404 406 414 458 459 461 465 507 508 510 508 ODAmps 8.5 10.9 12.1 12.2 14.0 13.9 13.9 14.1 16.0 16.0 16.0 16.1 18.2 18.2 18.2 18.3 20.7 20.7 20.7 20.8 19.7 19.7 19.7 18.3 TotallPower 2140 2749 3037 3069 3470 3467 3459 3492 3942 3939 3931 3964 4453 4449 4442 4474 5023 5020 5013 5045 4760 4757 4751 4415 Capacity 40.9 43.4 43.9 45.7 41.7 42.3 43.5 45.3 40.6 41.2 42.4 44.3 38.8 39.4 40.6 42.5 36.6 37.1 38.4 40.2 33.6 34.2 35.3 35.4 S/T 0.81 0.73 0.60 0.46 0.81 0.73 0.60 0.47 0.83 0.76 0.63 0.49 1.00 0.78 0.65 0.51 1.00 0.80 0.67 0.53 1.00 1.00 0.73 0.59 Evap dT 22 20 16 13 21 19 16 13 21 20 16 13 21 19 16 13 21 19 16 12 23 21 18 14 1520 PrSuc 122 123 123 127 125 127 129 134 131 133 136 140 136 138 141 148 144 145 148 153 155 156 159 166 PrDis 269 273 275 280 314 315 317 322 358 360 362 366 406 407 409 416 460 461 463 468 509 511 512 511 ODAmps 10.3 11.0 12.2 12.3 14.1 14.0 14.0 14.2 16.1 16.1 16.1 16.2 18.3 18.3 18.3 18.4 20.8 20.8 20.8 20.9 19.8 19.8 19.8 18.4 TotalPowe 2583 2769 3059 3091 3492 3489 3482 3514 3964 3961 3954 3986 4475 4471 4464 4497 5045 5042 5035 5067 4778 4775 4769 4431 IDB*: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. Shaded area reflects ACCA (TVA) Airflow may vary depending on actual ambient conditions and system operation modes. kW =Total system power Amps = outdoor unit amps x z m n O O z C) sz 77 0 3 0 0 0 0 91 OUTDOOR AMBIENT TEMPERATURE 65*F 75*F 85*F I 95*F 105°F 115°F D: ENTERING INDOOR WET BULB TEMPERATURE Capacity 32.5 40.3 43.4 44.5 40.5 41.0 42.3 44.1 39.4 40.0 41.2 43.1 37.6 38.2 39.4 41.2 35.3 35.9 37.1 39.0 32.5 33.0 34.2 34.3 S/T 0.86 0.75 0.61 0.47 0.82 0.74 0.61 0.48 1.00 0.77 0.64 0.50 1.00 0.79 0.66 0.52 1.00 0.81 0.68 0.54 1.00 1.00 0.74 0.60 Evap dT 27 27 24 19 28 26 22 19 28 26 23 19 28 26 22 19 27 26 22 19 30 28 24 20 1120 PrSuc 122 120 122 124 121 123 126 131 127 129 132 137 133 134 137 144 140 141 144 149 151 153 156 162 PrDis 251 265 270 275 309 311 312 317 354 355 357 361 401 402 404 411 455 457 458 463 505 506 508 506 ODAmps 7.5 10.1 10.8 12.1 13.9 13.8 13.8 13.9 15.9 15.9 15.9 16.0 18.1 18.1 18.1 18.2 20.6 20.6 20.6 20.7 19.7 19.6 19.6 18.2 TotalPower 1895 2542 2721 3044 3445 3442 3435 3467 3917 3914 3907 3939 4428 4425 4417 4450 4998 4995 4988 5020 4740 4737 4731 4395 Capacity 35.7 42.8 43.3 45.1 41.1 41.7 42.9 44.8 40.0 40.6 41.8 43.7 38.2 38.8 40.0 41.9 36.0 36.6 37.8 39.6 33.1 33.6 34.8 34.9 S/T 0.91 0.81 0.68 0.54 1.00 0.82 0.69 0.55 1.00 0.84 0.71 0.57 1.00 0.86 0.73 0.59 1.00 0.88 0.75 0.61 1.00 1.00 0.81 0.67 Evap dT 27 26 21 18 26 25 21 18 27 25 21 18 26 24 21 18 26 24 21 17 28 26 23 19 80 1320 PrSuc 122 121 121 126 123 125 128 133 129 131 134 139 135 136 139 146 142 143 146 151 153 155 158 164 PrDis 259 271 273 278 312 313 315 320 356 357 359 364 404 405 407 414 458 459 461 466 507 508 510 509 ODAmps 8.5 11.0 12.1 12.2 14.0 14.0 13.9 14.1 16.0 16.0 16.0 16.1 18.2 18.2 18.2 18.3 20.7 20.7 20.7 20.8 19.8 19.7 19.7 18.3 TotalPower 2141 2751 3039 3071 3472 3469 3462 3494 3944 3941 3934 3966 4455 4452 4444 4477 5026 5022 5015 5047 4762 4759 4753 4416 Capacity 41.1 43.6 44.1 45.9 41.9 42.5 43.7 45.6 40.8 41.4 42.6 44.5 39.0 39.6 40.8 42.7 36.8 37.4 38.6 40.4 33.8 34.4 35.5 35.6 S/T 1.00 0.85 0.72 0.58 1.00 0.85 0.72 0.59 1.00 0.88 0.75 0.61 1.00 0.90 0.77 0.63 1.00 1.00 0.79 0.65 1.00 1.00 0.85 0.71 Evap dT 26 25 20 17 25 23 20 17 25 24 20 17 25 23 20 17 25 23 20 16 27 25 22 18 1520 PrSuc 123 123 123 128 126 127 130 135 132 133 136 141 137 138 141 148 144 146 149 154 155 157 160 166 PrDis 269 273 276 280 315 316 318 323 359 360 362 367 406 408 410 417 461 462 464 469 510 511 513 511 ODAmps 10.3 11.0 12.2 12.3 14.1 14.1 14.0 14.2 16.1 16.1 16.1 16.2 18.3 18.3 18.3 18.4 20.8 20.8 20.8 20.9 19.8 19.8 19.8 18.4 TotalPowerl 2584 2771 3061 3093 3494 3491 3484 3516 3966 3963 3956 3988 4477 4474 4466 4499 5048 5044 5037 5069 4779 4777 4771 4433 Capacity 33.0 41.0 44.1 45.2 41.2 41.7 42.9 44.8 40.1 40.7 41.9 43.7 38.3 38.8 40.1 41.9 36.0 36.6 37.8 39.7 33.1 33.7 34.9 34.9 S/T 1.00 0.85 0.71 0.57 1.00 0.84 0.71 0.57 1.00 0.87 0.74 0.60 1.00 1.00 0.75 0.62 1.00 1.00 0.78 0.64 1.00 1.00 0.84 0.70 Evap dT 31 31 27 23 31 29 26 23 31 30 26 23 31 29 26 23 31 29 26 22 33 31 28 24 1120 PrSuc 124 121 124 125 123 124 127 132 129 131 133 138 134 136 139 146 142 143 146 151 153 154 157 163 PrDis 252 267 271 276 311 312 314 318 355 356 358 362 402 403 405 413 457 458 460 464 506 507 509 507 ODAm ps 7.5 10.1 10.9 12.1 13.9 13.9 13.8 14.0 15.9 15.9 15.9 16.0 18.2 18.1 18.1 18.3 20.6 20.6 20.6 20.7 19.7 19.7 19.6 18.2 TotalPowet 1900 2549 2728 3052 3453 3450 3443 3475 3925 3922 3915 3947 4436 4433 4425 4458 5007 5003 4996 5028 4747 4744 4738 4401 Capacity 36.3 43.5 43.9 45.8 41.8 42.4 43.6 45.4 40.7 41.3 42.5 44.4 38.9 39.5 40.7 42.5 36.7 37.2 38.5 40.3 33.7 34.3 35.5 35.5 S/T 1.00 0.91 0.78 0.64 1.00 0.92 0.78 0.65 1.00 0.94 0.81 0.67 1.00 1.00 0.83 0.69 1.00 1.00 0.85 0.71 1.00 1.00 1.00 0.77 Evap dT 30 30 25 21 30 28 25 21 30 28 25 21 30 28 25 21 30 28 24 21 32 30 27 23 85 1320 PrSuc 124 123 122 127 125 126 129 134 131 133 135 140 136 138 141 148 144 145 148 153 155 156 159 166 PrDis 261 272 274 279 313 315 316 321 358 359 361 365 405 406 408 416 459 461 462 467 509 510 512 510 ODAmps 8.5 11.0 12.1 12.3 14.0 14.0 14.0 14.1 16.1 16.0 16.0 16.2 18.3 18.3 18.2 18.4 20.8 20.7 20.7 20.9 19.8 19.8 19.7 18.3 iTotallPower 2147 2758 3047 3079 3480 3477 3470 3502 3952 3949 3942 3974 4463 4460 4452 4485 5034 5030 5023 5055 4769 4766 4760 4422 Capacity 41.8 44.3 44.7 46.6 42.6 43.2 44.4 46.2 41.5 42.1 43.3 45.2 39.7 40.3 41.5 43.3 37.5 38.0 39.3 41.1 34.5 35.0 36.2 36.2 S/T 1.00 0.95 0.82 0.68 1.00 0.95 0.82 0.68 1.00 0.98 0.85 0.71 1.00 1.00 0.86 0.73 1.00 1.00 0.89 0.75 1.00 1.00 1.00 0.81 Evap dT 30 28 24 20 29 27 24 20 29 27 24 20 29 27 24 20 28 27 23 20 31 29 26 22 1520 PrSuc 124 125 125 130 127 129 132 137 133 135 138 143 139 140 143 150 146 147 150 155 157 159 162 168 PrDis 271 275 277 282 316 317 319 324 360 361 363 368 408 409 411 418 462 463 465 470 511 512 514 513 ODAmps 10.3 11.1 12.2 12.4 14.1 14.1 14.1 14.2 16.2 16.1 16.1 16.2 18.4 18.4 18.3 18.5 20.9 20.8 20.8 20.9 19.9 19.8 19.8 18.4 TotalPowe 2591 2778 3069 3102 3502 3499 3492 3524 3974 3971 3964 3996 4485 4482 4475 4507 5056 5052 5045 5078 4786 4783 4777 4439 IDB*: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. Shaded area reflects AHRI conditions Airflow may vary depending on actual ambient conditions and system operation modes. kW =Total system power Amps = outdoor unit amps k n Z) N N V Ln N I� 00 T m n a F-� �JF OUTDOOR AMBIENT TEMPERATURE 65'F 757E 857E 1 957E 105"F 115"F ENTERING INDOOR WET BULB TEMPERATURE D: Capacity 35.5 40.6 47.5 - 45.8 46.4 47.8 - 44.6 45.2 46.6 - 42.5 43.1 44.5 - 39.9 40.6 42.0 - 32.6 33.2 34.3 - S/T 0.58 0.50 0.36 0.56 0.49 0.36 0.59 0.52 0.39 0.61 0.53 0.41 0.63 0.56 0.43 1.00 0.62 0.49 Evap dT 21 19 16 21 19 15 21 19 16 21 19 15 20 19 15 22 20 17 1170 PrSuc 120 119 120 120 121 124 126 127 130 131 132 135 136 137 140 148 150 153 PrDis 257 266 277 320 321 323 366 367 369 415 416 418 468 469 471 504 505 507 ODAmps 8.7 10.5 13.1 17.1 17.1 17.1 19.7 19.7 19.6 22.5 22.5 22.4 25.6 25.6 25.5 20.5 20.5 20.5 TotalPower 2,212 2,642 3,269 4,232 4,228 4,219 4,823 4,819 4,810 5,462 5,458 5,449 6,177 6,173 6,163 4937 4934 4928 Capacity 42.4 46.8 48.9 46.5 47.1 48.5 45.3 45.9 47.3 43.2 43.9 45.2 40.7 41.3 42.7 33.2 33.8 35.0 S/T 0.64 0.56 0.43 0.63 0.56 0.43 0.66 0.59 0.46 0.68 0.60 0.48 0.70 0.63 0.50 1.00 0.69 0.56 Evap dT 20 18 14 19 17 14 20 18 14 19 17 14 19 17 14 21 19 15 70 1380 PrSuc 119 119 119 122 123 126 128 129 132 133 134 137 138 139 142 150 152 155 PrDis 271 278 282 323 324 326 369 370 372 418 419 421 471 472 474 506 507 509 ODAmps 11.4 13.2 14.9 17.3 17.3 17.2 19.8 19.8 19.8 22.6 22.6 22.6 25.7 25.7 25.7 20.6 20.6 20.6 TotalPower 2862 3306 3723 4266 4262 4252 4856 4852 4843 5496 5492 5483 6210 6206 6197 4960 4957 4951 Capacity 44.9 47.7 49.8 47.4 48.0 49.4 46.2 46.8 48.2 44.1 44.7 46.1 41.5 42.2 43.6 33.9 34.5 35.7 S/T 0.67 0.60 0.46 0.67 0.60 0.47 0.69 0.62 0.49 0.71 0.64 0.51 0.73 0.66 0.53 1.00 0.72 0.59 Evap dT 19 17 13 18 16 13 18 17 13 18 16 13 18 16 12 20 18 14 1590 PrSuc 121 121 121 124 125 128 130 131 134 135 137 139 140 142 144 153 154 157 PrDis 276 281 285 325 327 329 371 372 374 420 422 424 474 475 477 509 510 512 ODAmps 12.3 13.4 15.0 17.4 17.4 17.3 20.0 19.9 19.9 22.7 22.7 22.7 25.8 25.8 25.8 20.7 20.7 20.6 TotalPower 3083 3330 3750 4292 4288 4279 4883 4879 4870 5523 5518 5509 6237 6233 6224 4978 4976 4969 Capacity 35.5 40.6 47.5 50.4 45.8 46.5 47.8 50.0 44.6 45.3 46.6 48.7 42.5 43.2 44.6 46.7 40.0 40.6 42.0 41.5 32.6 33.2 34.4 34.5 S/T 0.71 0.62 0.48 0.35 0.69 0.61 0.49 0.35 0.71 0.64 0.51 0.37 0.73 0.66 0.53 0.39 1.00 0.68 0.55 0.41 1.00 0.74 0.61 0.48 Evap dT 25 24 20 16 25 23 19 16 25 23 20 16 25 23 19 16 25 23 19 16 26 24 21 17 1170 PrSuc 120 119 120 122 120 121 124 129 126 127 130 135 131 132 135 140 136 137 140 149 148 150 153 159 PrDis 258 267 277 284 320 321 323 328 366 367 369 374 415 416 418 423 468 470 471 466 504 505 507 505 ODAmps 8.7 10.5 13.1 14.9 17.1 17.1 17.1 17.2 19.7 19.7 19.6 19.8 22.5 22.4 22.4 22.6 25.6 25.6 25.5 20.9 20.5 20.5 20.4 19.0 TotalPower 2210 2640 3266 3727 4229 4225 4216 4256 4820 4816 4806 4847 5459 5455 5446 5486 6173 6169 6160 5047 4935 4932 4926 4583 Capacity 42.4 46.8 49.0 51.1 46.5 47.2 48.6 50.7 45.3 46.0 47.3 49.5 43.2 43.9 45.3 47.4 40.7 41.3 42.7 42.2 33.2 33.8 35.0 35.1 S/T 0.76 0.68 0.55 0.42 0.76 0.68 0.56 0.42 0.78 0.71 0.58 0.45 0.80 0.73 0.60 0.46 1.00 0.75 0.62 0.49 1.00 0.81 0.68 0.55 Evap dT 24 23 18 14 23 22 18 14 24 22 18 15 23 22 18 14 23 21 18 15 25 23 19 15 75 1380 PrSuc 119 119 119 124 122 123 126 131 128 129 132 137 133 134 137 142 138 139 142 151 150 152 155 161 PrDis 271 278 282 287 323 324 326 331 369 370 372 377 418 419 421 426 471 472 474 469 506 508 509 508 ODAmps 11.4 13.2 14.9 15.1 17.3 17.2 17.2 17.4 19.8 19.8 19.8 20.0 22.6 22.6 22.6 22.7 25.7 25.7 25.7 21.0 20.6 20.6 20.5 19.1 TotalPower 2859 3303 3720 3760 4262 4258 4249 4290 4853 4849 4840 4880 5492 5488 5479 5520 6207 6202 6193 5075 4958 4955 4948 4605 Capacity 45.0 47.7 49.8 52.0 47.4 48.0 49.4 51.5 46.2 46.8 48.2 50.3 44.1 44.8 46.1 48.3 41.6 42.2 43.6 43.0 34.0 34.5 35.7 35.9 S/T 0.79 0.72 0.59 0.45 0.79 0.72 0.59 0.46 0.82 0.74 0.62 0.48 1.00 0.76 0.63 0.50 1.00 0.78 0.66 0.52 1.00 0.85 0.72 0.59 Evap dT 23 22 17 13 22 20 17 13 23 21 17 14 22 20 17 13 22 20 17 14 24 22 18 14 1590 PrSuc 121 121 121 126 124 125 128 133 130 131 134 139 135 137 139 144 140 142 144 154 153 154 157 164 PrDis 276 281 285 290 326 327 329 334 371 373 375 379 421 422 424 429 474 475 477 472 509 510 512 511 ODAmps 12.3 13.3 15.0 15.2 17.4 17.4 17.3 17.5 19.9 19.9 19.9 20.1 22.7 22.7 22.7 22.8 25.8 25.8 25.8 21.1 20.7 20.6 20.6 19.2 TotalPower 3080 3327 3747 3787 4289 4285 4276 4316 4880 4876 4867 4907 5519 5515 5506 5546 6233 6229 6220 5097 4976 4973 4967 4622 IDB*: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. Shaded area reflects ACCA (TVA) Airflow may vary depending on actual ambient conditions and system operation modes. kW = Total system power Amps = outdoor unit amps x z m n O O z C) sz 77 0 3 0 0 0 0 91 OUTDOOR AMBIENT TEMPERATURE 65*F 75*F 85*F I 95*F 105°F 115°F D: ENTERING INDOOR WET BULB TEMPERATURE Capacity 35.7 44.3 47.7 50.6 46.0 46.7 48.1 50.2 44.8 45.5 46.9 49.0 42.8 43.4 44.8 46.9 40.2 40.9 42.3 41.7 32.8 33.4 34.6 34.7 5/T 0.84 0.73 0.60 0.46 0.80 0.73 0.60 0.47 1.00 0.76 0.63 0.49 1.00 0.77 0.65 0.51 1.00 0.80 0.67 0.53 1.00 1.00 0.73 0.60 Evap dT 29 28 25 20 29 27 24 20 29 27 24 20 29 27 24 20 29 27 23 21 31 29 25 21 1170 PrSuc 121 118 120 123 120 122 125 129 126 128 131 135 131 133 136 141 136 138 141 150 149 150 153 160 PrDis 258 272 278 285 321 322 324 329 366 368 370 374 416 417 419 424 469 470 472 467 504 505 507 506 ODAmps 8.7 12.1 13.1 14.9 17.1 17.1 17.1 17.3 19.7 19.7 19.6 19.8 22.5 22.5 22.4 22.6 25.6 25.6 25.5 20.9 20.5 20.5 20.5 19.0 TotalPower 2211 3029 3268 3730 4232 4228 4219 4259 4822 4818 4809 4850 5462 5458 5449 5489 6176 6172 6163 5050 4937 4934 4928 4585 Capacity 42.6 47.1 49.2 51.3 46.8 47.4 48.8 50.9 45.5 46.2 47.6 49.7 43.5 44.1 45.5 47.6 40.9 41.6 43.0 42.4 33.4 34.0 35.2 35.3 S/T 0.89 0.80 0.67 0.53 0.88 0.80 0.68 0.54 1.00 0.83 0.70 0.56 1.00 0.85 0.72 0.58 1.00 0.87 0.74 0.61 1.00 1.00 0.80 0.67 Evap dT 29 27 22 19 28 26 22 19 28 26 22 19 28 26 22 19 27 25 22 19 29 27 24 20 80 1380 PrSuc 120 119 120 125 122 124 127 131 128 130 133 137 133 135 138 143 138 140 143 152 151 152 155 162 PrDis 271 279 283 288 324 325 327 331 369 370 372 377 419 420 422 427 472 473 475 470 507 508 510 509 ODAmps 11.4 13.2 14.9 15.1 17.3 17.3 17.2 17.4 19.8 19.8 19.8 20.0 22.6 22.6 22.6 22.7 25.7 25.7 25.7 21.0 20.6 20.6 20.5 19.1 TotalPower 2861 3305 3723 3763 4265 4261 4252 4292 4856 4852 4843 4883 5495 5491 5482 5522 6209 6205 6196 5077 4960 4957 4950 4606 Capacity 45.2 48.0 50.1 52.2 47.6 48.3 49.7 51.8 46.4 47.1 48.5 50.6 44.3 45.0 46.4 48.5 41.8 42.5 43.8 43.2 34.2 34.7 35.9 36.1 S/T 0.91 0.84 0.70 0.57 1.00 0.84 0.71 0.58 1.00 0.86 0.73 0.60 1.00 0.88 0.75 0.62 1.00 0.90 0.77 0.64 1.00 1.00 0.84 0.71 Evap dT 28 26 21 17 27 25 21 17 27 25 21 18 27 25 21 17 26 24 21 18 28 26 23 19 1590 PrSuc 121 122 122 127 125 126 129 134 131 132 135 140 136 137 140 145 141 142 145 154 153 155 158 164 PrDis 277 281 286 291 326 327 329 334 372 373 375 380 421 422 424 429 474 476 477 472 509 511 513 511 ODAmps 12.3 13.3 15.0 15.2 17.4 17.4 17.3 17.5 20.0 19.9 19.9 20.1 22.7 22.7 22.7 22.9 25.8 25.8 25.8 21.1 20.7 20.7 20.6 19.2 TotalPower 3082 3329 3749 3790 4292 4288 4279 4319 4883 4878 4869 4910 5522 5518 5509 5549 6236 6232 6223 5099 4978 4975 4969 4624 Capacity 36.3 41.5 48.5 51.4 46.8 47.5 48.9 51.0 45.6 46.3 47.7 49.8 43.5 44.2 45.6 47.7 41.0 41.6 43.0 42.4 33.5 34.1 35.3 35.4 S/T 1.00 0.84 0.70 0.56 1.00 0.83 0.70 0.57 1.00 0.85 0.72 0.59 1.00 0.87 0.74 0.61 1.00 1.00 0.76 0.63 1.00 1.00 0.83 0.70 Evap dT 33 32 29 24 33 31 27 24 33 31 28 24 33 31 27 24 32 31 27 24 35 33 29 25 1170 PrSuc 122 122 122 124 122 123 126 131 128 129 132 137 133 135 137 142 138 140 142 152 151 152 155 161 PrDis 259 268 279 286 322 323 325 330 368 369 371 376 417 418 420 425 470 471 473 468 506 507 509 507 ODAmps 8.8 10.5 13.1 15.0 17.2 17.2 17.1 17.3 19.7 19.7 19.7 19.9 22.5 22.5 22.5 22.6 25.6 25.6 25.6 20.9 20.5 20.5 20.5 19.0 TotalPower 2217 2649 3277 3740 4242 4238 4229 4269 4833 4828 4819 4860 5472 5468 5459 5499 6186 6182 6173 5058 4944 4941 4935 4592 Capacity 43.3 47.9 50.0 52.1 47.5 48.2 49.6 51.7 46.3 47.0 48.4 50.5 44.2 44.9 46.3 48.4 41.7 42.4 43.7 43.1 34.1 34.7 35.9 35.9 S/T 1.00 0.90 0.76 0.63 1.00 0.90 0.77 0.64 1.00 0.92 0.79 0.66 1.00 1.00 0.81 0.68 1.00 1.00 0.83 0.70 1.00 1.00 0.90 0.77 Evap dT 33 31 26 22 31 29 26 22 32 30 26 23 31 29 26 22 31 29 26 23 33 31 28 24 85 1380 PrSuc 121 121 121 126 124 125 128 133 130 131 134 139 135 137 139 144 140 142 144 154 153 154 157 163 PrDis 273 280 284 289 325 326 328 333 371 372 374 379 420 421 423 428 473 474 476 471 508 509 511 510 ODAmps 11.5 13.3 15.0 15.1 17.3 17.3 17.3 17.4 19.9 19.9 19.8 20.0 22.7 22.7 22.6 22.8 25.8 25.8 25.7 21.0 20.6 20.6 20.6 19.1 TotalPower 2869 3314 3733 3773 4275 4271 4262 4302 4866 4862 4853 4893 5505 5501 5492 5532 6219 6215 6206 5085 4967 4964 4957 4613 Capacity 45.9 48.7 50.9 53.0 48.4 49.1 50.4 52.6 47.2 47.9 49.2 51.4 45.1 45.8 47.2 49.3 42.6 43.2 44.6 44.0 34.9 35.4 36.6 36.7 S/T 1.00 0.93 0.80 0.67 1.00 0.93 0.81 0.67 1.00 0.96 0.83 0.69 1.00 1.00 0.85 0.71 1.00 1.00 0.87 0.74 1.00 1.00 1.00 0.81 Evap dT 32 30 25 21 30 28 25 21 31 29 25 21 30 28 25 21 30 28 25 22 32 30 26 22 1590 PrSuc 123 123 124 128 126 128 130 135 132 134 137 141 137 139 142 146 142 144 147 156 155 156 159 166 PrDis 278 283 287 292 328 329 331 335 373 374 376 381 423 424 426 430 476 477 479 474 511 512 514 513 ODAmps 12.4 13.4 15.1 15.3 17.4 17.4 17.4 17.6 20.0 20.0 19.9 20.1 22.8 22.8 22.7 22.9 25.9 25.9 25.8 21.1 20.7 20.7 20.7 19.2 TotalPower 3090 3338 3760 3800 4302 4298 4289 4329 4893 4889 4879 4920 5532 5528 5519 5559 6246 6242 6233 5107 4985 4982 4976 4630 IDB*: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. Shaded area reflects AHRI conditions Airflow may vary depending on actual ambient conditions and system operation modes. kW = Total system power Amps = outdoor unit amps k Z) N N V Ln 00 I� 00 T m n a H IN �JF OUTDOOR AMBIENT TEMPERATURE 651F 751F 851E 1 951E 1051E 1151E ENTERING INDOOR WET BULB TEMPERATURE D: Capacity 41.7 50.3 56.7 - 54.3 55.1 56.8 - 52.9 53.7 55.3 - 50.4 51.2 52.9 - 42.9 43.6 45.1 - 34.0 34.6 35.8 - S/T 0.56 0.47 0.35 0.55 0.48 0.35 0.57 0.50 0.38 0.59 0.52 0.40 0.61 0.54 0.41 1.00 0.60 0.48 Evap dT 20 19 15 20 18 15 20 18 15 20 18 15 20 18 15 20 19 15 1390 PrSuc 114 112 114 112 113 116 118 119 122 122 124 126 134 135 138 144 145 148 PrDis 251 261 268 310 312 314 355 356 358 403 404 406 440 441 443 476 477 479 ODAmps 10.4 13.6 15.9 20.2 20.2 20.2 23.3 23.3 23.2 26.6 26.6 26.5 23.3 23.3 23.3 20.1 20.1 20.1 TotalPower 2,655 3,446 4,031 5,024 5,019 5,008 5,725 5,720 5,709 6,483 6,478 6,467 5,693 5,689 5,681 4897 4894 4888 Capacity 48.0 53.5 58.1 55.2 56.0 57.6 53.7 54.5 56.2 51.3 52.0 53.7 43.7 44.4 45.9 34.6 35.2 36.5 S/T 0.62 0.54 0.42 0.62 0.55 0.42 0.64 0.57 0.45 0.66 0.59 0.46 0.68 0.61 0.49 1.00 0.68 0.55 Evap dT 19 17 13 19 17 13 19 17 14 18 17 13 19 17 13 19 17 14 70 1640 PrSuc 114 114 111 114 115 118 119 121 123 124 126 128 136 137 140 146 147 150 PrDis 260 266 274 313 314 316 358 359 361 405 407 408 443 444 446 479 480 482 ODAmps 12.6 14.9 17.6 20.4 20.4 20.3 23.4 23.4 23.4 26.7 26.7 26.7 23.5 23.4 23.4 20.2 20.2 20.2 TotalPower 3215 3768 4419 5063 5058 5047 5764 5759 5748 6522 6517 6507 5724 5720 5712 4920 4917 4911 Capacity 51.4 56.9 59.1 56.2 57.0 58.6 54.8 55.6 57.2 52.3 53.1 54.7 44.7 45.4 46.8 35.5 36.1 37.3 S/T 0.65 0.57 0.45 0.65 0.58 0.46 0.67 0.60 0.48 0.69 0.62 0.50 0.72 0.65 0.52 1.00 0.71 0.58 Evap dT 18 16 12 17 16 12 18 16 12 17 16 12 18 16 12 18 16 13 1890 PrSuc 115 115 113 116 117 120 122 123 126 126 128 130 138 139 142 148 150 153 PrDis 265 272 277 316 317 319 360 361 363 408 409 411 445 446 448 481 482 484 ODAmps 13.8 16.3 17.7 20.5 20.5 20.5 23.6 23.6 23.5 26.9 26.9 26.8 23.6 23.6 23.5 20.3 20.3 20.3 ITotalPowerl 3506 4106 4452 5095 5090 5079 5796 5791 5780 6554 6549 6539 5749 5745 5737 4938 4936 4929 Capacity 41.7 50.4 56.7 59.8 54.4 55.1 56.8 59.3 52.9 53.7 55.4 57.9 50.5 51.2 52.9 55.4 42.9 43.6 45.1 45.2 34.0 34.6 35.8 35.6 S/T 0.68 0.59 0.46 0.34 0.67 0.60 0.47 0.34 0.69 0.62 0.50 0.36 0.71 0.64 0.51 0.38 1.00 0.66 0.53 0.41 1.00 0.73 0.60 0.47 Evap dT 24 23 20 15 24 22 19 15 24 22 19 15 24 22 19 15 24 22 19 15 24 23 19 15 1390 PrSuc 114 112 114 114 112 113 116 121 118 119 122 126 122 124 126 131 134 135 138 144 144 145 148 155 PrDis 251 261 268 276 311 312 314 318 355 356 358 363 403 404 406 411 440 441 443 443 476 478 479 479 ODAmps 10.4 13.5 15.9 17.6 20.2 20.2 20.1 20.3 23.3 23.2 23.2 23.4 26.6 26.5 26.5 26.7 23.3 23.3 23.3 21.5 20.1 20.1 20.1 18.6 TotalPower 2652 3443 4027 4424 5020 5015 5004 5052 5721 5716 5705 5753 6479 6474 6463 6511 5690 5686 5678 5261 4894 4891 4885 4531 Capacity 48.0 53.5 58.1 60.6 55.2 56.0 57.6 60.1 53.8 54.5 56.2 58.7 51.3 52.1 53.7 56.2 43.7 44.4 45.9 45.9 34.7 35.3 36.5 36.2 S/T 0.74 0.66 0.53 0.40 0.73 0.66 0.54 0.41 0.76 0.69 0.56 0.43 0.78 0.71 0.58 0.45 1.00 0.73 0.60 0.48 1.00 0.80 0.67 0.54 Evap dT 23 22 17 14 23 21 17 14 23 21 18 14 22 21 17 14 23 21 18 14 23 21 18 14 75 1640 PrSuc 114 114 111 116 114 115 118 122 119 121 123 128 124 126 128 133 136 137 140 146 146 147 150 157 PrDis 260 267 274 279 313 315 316 321 358 359 361 366 406 407 409 413 443 444 446 446 479 480 482 482 ODAmps 12.6 14.9 17.6 17.8 20.4 20.4 20.3 20.5 23.4 23.4 23.4 23.6 26.7 26.7 26.7 26.9 23.5 23.4 23.4 21.6 20.2 20.2 20.2 18.7 TotalPower 3212 3764 4415 4463 5059 5054 5043 5091 5760 5755 5744 5792 6518 6513 6503 6551 5721 5717 5709 5288 4917 4914 4908 4552 Capacity 51.4 57.0 59.2 61.7 56.3 57.0 58.7 61.2 54.8 55.6 57.2 59.7 52.4 53.1 54.8 57.3 44.7 45.4 46.9 46.8 35.5 36.1 37.3 37.0 S/T 0.77 0.69 0.57 0.44 0.77 0.70 0.58 0.44 0.79 0.72 0.60 0.47 0.81 0.74 0.62 0.48 1.00 0.76 0.64 0.52 1.00 0.84 0.71 0.58 Evap dT 22 21 16 13 21 20 16 13 22 20 16 13 21 20 16 13 22 20 16 13 22 20 17 13 1890 PrSuc 115 115 113 118 116 117 120 124 122 123 126 130 126 128 130 135 138 139 142 148 148 150 153 159 PrDis 265 272 277 281 316 317 319 324 360 362 364 368 408 409 411 416 445 447 448 448 482 483 484 484 ODAmps 13.8 16.2 17.7 17.9 20.5 20.5 20.5 20.7 23.6 23.5 23.5 23.7 26.9 26.8 26.8 27.0 23.6 23.5 23.5 21.7 20.3 20.3 20.2 18.8 TotalPowe 3502 4103 4448 4496 5091 5086 5075 5123 5792 5787 5776 5824 6550 6545 6535 6583 5746 5742 5734 5311 4936 4933 4927 4569 IDB*: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. Shaded area reflects ACCA (TVA) Airflow may vary depending on actual ambient conditions and system operation modes. kW = Total system power Amps = outdoor unit amps k n Z m n O O z C) sz 77 0 3 0 0 0 0 91 OUTDOOR AMBIENT TEMPERATURE 65*F 75*F 85*F I 95*F 105°F 115°F D: ENTERING INDOOR WET BULB TEMPERATURE Capacity 42.0 50.6 57.0 60.1 54.7 55.4 57.1 59.6 53.2 54.0 55.6 58.1 50.8 51.5 53.2 55.7 43.2 43.9 45.4 45.4 34.2 34.8 36.1 35.8 S/T 0.80 0.71 0.58 0.45 0.78 0.71 0.59 0.46 0.80 0.73 0.61 0.48 1.00 0.75 0.63 0.50 1.00 0.77 0.65 0.53 1.00 1.00 0.72 0.59 Evap dT 27 27 24 19 28 26 23 19 28 26 23 19 28 26 23 19 29 27 23 19 28 26 23 19 1390 PrSuc 115 113 114 115 112 114 116 121 118 119 122 127 123 124 127 131 134 136 138 144 144 146 149 155 PrDis 251 261 269 277 311 312 314 319 356 357 359 363 403 405 406 411 441 442 444 443 477 478 480 480 ODAmps 10.4 13.6 15.9 17.6 20.2 20.2 20.2 20.4 23.3 23.2 23.2 23.4 26.6 26.5 26.5 26.7 23.3 23.3 23.3 21.5 20.1 20.1 20.1 18.6 TotalPower 2654 3445 4030 4428 5023 5018 5007 5055 5724 5719 5708 5756 6482 6477 6467 6515 5692 5688 5680 5263 4896 4893 4887 4533 Capacity 48.3 53.8 58.4 60.9 55.5 56.3 57.9 60.4 54.1 54.8 56.5 59.0 51.6 52.4 54.0 56.5 44.0 44.7 46.2 46.1 34.9 35.5 36.7 36.4 S/T 0.86 0.78 0.65 0.52 0.85 0.78 0.66 0.52 0.87 0.80 0.68 0.55 1.00 0.82 0.70 0.57 1.00 0.85 0.72 0.60 1.00 1.00 0.79 0.66 Evap dT 27 26 21 18 27 25 21 18 27 25 22 18 27 25 21 18 27 25 22 18 27 25 22 18 80 1640 PrSuc 114 114 112 116 114 116 118 123 120 121 124 128 125 126 129 133 136 138 140 146 147 148 151 157 PrDis 260 267 275 279 314 315 317 322 358 359 361 366 406 407 409 414 443 444 446 446 480 481 482 482 ODAmps 12.6 14.9 17.6 17.8 20.4 20.4 20.3 20.5 23.4 23.4 23.4 23.6 26.7 26.7 26.7 26.9 23.5 23.4 23.4 21.7 20.2 20.2 20.2 18.7 TotalPower 3215 3767 4419 4467 5062 5057 5047 5095 5763 5758 5747 5795 6521 6517 6506 6554 5723 5720 5712 5291 4919 4916 4910 4553 Capacity 51.6 57.2 59.5 62.0 56.5 57.3 59.0 61.5 55.1 55.9 57.5 60.0 52.6 53.4 55.1 57.6 44.9 45.6 47.1 47.0 35.7 36.3 37.5 37.2 S/T 0.88 0.80 0.68 0.55 0.88 0.81 0.69 0.56 0.91 0.84 0.71 0.58 1.00 0.86 0.73 0.60 1.00 0.88 0.76 0.63 1.00 1.00 0.83 0.70 Evap dT 26 25 20 17 25 24 20 17 26 24 20 17 25 24 20 17 26 24 21 17 26 24 21 17 1890 PrSuc 116 115 114 118 116 118 120 125 122 123 126 131 127 128 131 135 138 140 143 149 149 150 153 159 PrDis 266 272 277 282 317 318 320 324 361 362 364 369 409 410 412 416 446 447 449 449 482 483 485 485 ODAmps 13.8 16.3 17.7 17.9 20.5 20.5 20.5 20.7 23.6 23.6 23.5 23.7 26.9 26.9 26.8 27.0 23.6 23.6 23.5 21.8 20.3 20.3 20.2 18.8 TotalPower 3505 4106 4451 4499 5094 5089 5079 5127 5795 5790 5780 5828 6554 6549 6538 6586 5748 5744 5736 5313 4938 4935 4929 4570 Capacity 42.7 51.5 57.9 61.0 55.6 56.4 58.0 60.5 54.1 54.9 56.6 59.1 51.7 52.5 54.1 56.6 44.0 44.7 46.2 46.2 34.9 35.5 36.8 36.5 S/T 1.00 0.80 0.67 0.54 1.00 0.80 0.68 0.55 1.00 0.83 0.70 0.57 1.00 0.85 0.72 0.59 1.00 1.00 0.74 0.62 1.00 1.00 0.81 0.69 Evap dT 31 31 28 23 31 30 26 23 32 30 26 23 31 30 26 23 32 30 27 23 32 30 27 23 1390 PrSuc 117 115 116 116 114 115 118 123 120 121 124 128 124 126 128 133 136 137 140 146 146 148 151 157 PrDis 253 263 270 278 312 314 316 320 357 358 360 365 405 406 408 412 442 443 445 445 478 479 481 481 ODAmps 10.4 13.6 16.0 17.7 20.3 20.3 20.2 20.4 23.3 23.3 23.3 23.5 26.6 26.6 26.6 26.8 23.4 23.4 23.3 21.6 20.1 20.1 20.1 18.6 TotalPower 2661 3455 4041 4440 5035 5030 5019 5067 5736 5731 5720 5768 6494 6489 6479 6527 5701 5698 5689 5271 4903 4900 4894 4539 Capacity 49.1 54.7 59.3 61.8 56.4 57.2 58.8 61.3 55.0 55.8 57.4 59.9 52.5 53.3 54.9 57.4 44.8 45.5 47.0 46.9 35.6 36.2 37.4 37.1 S/T 1.00 0.87 0.74 0.61 1.00 0.87 0.75 0.62 1.00 0.90 0.77 0.64 1.00 0.91 0.79 0.66 1.00 1.00 0.81 0.69 1.00 1.00 0.89 0.76 Evap dT 31 30 25 21 30 28 25 21 30 29 25 22 30 28 25 21 31 29 25 21 30 29 25 22 85 1640 PrSuc 116 116 113 118 116 117 120 124 122 123 126 130 126 128 130 135 138 139 142 148 148 150 153 159 PrDis 261 268 276 281 315 316 318 323 360 361 363 367 407 409 410 415 445 446 448 447 481 482 484 483 ODAmps 12.7 14.9 17.6 17.9 20.4 20.4 20.4 20.6 23.5 23.5 23.4 23.6 26.8 26.8 26.7 26.9 23.5 23.5 23.5 21.7 20.2 20.2 20.2 18.7 TotalPower 3223 3777 4431 4479 5074 5069 5059 5107 5775 5770 5759 5807 6534 6529 6518 6566 5733 5729 5721 5299 4926 4923 4917 4560 Capacity 52.5 58.2 60.4 62.9 57.5 58.2 59.9 62.4 56.0 56.8 58.5 61.0 53.6 54.3 56.0 58.5 45.8 46.5 48.0 47.8 36.4 37.0 38.2 37.9 S/T 1.00 0.89 0.78 0.65 1.00 0.91 0.78 0.65 1.00 0.93 0.81 0.67 1.00 0.95 0.82 0.69 1.00 1.00 0.85 0.73 1.00 1.00 0.92 0.80 Evap dT 30 29 24 20 29 27 24 20 29 27 24 21 29 27 24 20 30 28 24 20 29 28 24 20 1890 PrSuc 117 117 116 120 118 119 122 126 124 125 128 132 128 130 132 137 140 141 144 150 151 152 155 161 PrDis 267 274 278 283 318 319 321 326 362 363 365 370 410 411 413 418 447 448 450 450 483 484 486 486 ODAmps 13.9 16.3 17.8 18.0 20.6 20.6 20.5 20.7 23.6 23.6 23.6 23.8 26.9 26.9 26.9 27.1 23.6 23.6 23.6 21.8 20.3 20.3 20.3 18.8 TotalPowe 3514 4116 4463 4511 5106 5101 5091 5139 5807 5802 5792 5840 6566 6561 6550 6598 5757 5753 5745 5322 4945 4942 4936 4577 IDB*: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. Shaded area reflects AHRI conditions Airflow may vary depending on actual ambient conditions and system operation modes. kW = Total system power Amps = outdoor unit amps k n Z) N N V Ln O I� F VA EXPANDED HEATING DATA - STANDARD MODE DZI7VSA181A*+ DV24FECB14A* OUTDOOR AMBIENT TEMPERATURE .0 1 55 1 50 1 47 1 45 1 40 1 35 1 30 1 25 1 20 1 17 1 15 1 10 MBh 21.9 20.6 18.6 17.6 16.4 14.6 12.9 11.2 9.4 19.2 17.9 17.1 16.5 15.0 21.8 19.9 17.0 T/R 32 30 29 27 26 25 23 34 31 29 27 26 25 23 20 17 15 kW 1.40 1.37 1.33 1.30 1.29 1.27 1.24 2.13 2.05 1.98 1.91 1.87 1.84 1.77 1.70 1.63 1.56 Amps 5.1 5.0 4.8 4.7 4.6 4.6 4.4 8.3 8.0 7.7 7.4 7.2 7.1 6.8 6.4 6.1 5.8 COP 4.60 4.41 4.22 4.03 3.90 3.80 3.53 3.00 2.84 2.74 2.69 2.67 2.60 2.42 2.22 2.01 1.77 HI PR 373 361 348 336 329 324 312 360 345 331 316 307 302 287 273 258 244 LO PR 139 131 122 113 108 105 96 81 73 65 57 52 49 41 33 25 17 DZI7VSA241A*+ DV24FECB14A* OUTDOOR AMBIENT TEMPERATURE i 1 55 50 47 45 40 1 35 1 30 1 25 20 MBh 29.0 27.3 25.6 23.9 22.8 22.0 20.1 21.4 19.8 18.6 17.8 17.3 16.7 15.2 13.7 12.2 10.7 T/R 32 31 29 27 26 26 23 25 23 22 21 20 20 18 16 14 12 kW 1.88 1.85 1.81 1.78 1.76 1.74 1.71 1.95 1.90 1.84 1.79 1.76 1.74 1.69 1.64 1.59 1.54 Amps 6.9 6.8 6.6 6.5 6.4 6.3 6.2 7.2 7.0 6.8 6.5 6.4 6.3 6.1 5.9 5.6 5.4 COP 4.52 4.33 4.13 3.93 3.80 3.70 3.44 3.22 3.06 2.96 2.90 2.88 2.81 2.64 2.45 2.25 2.04 HI PR 380 367 355 343 335 330 318 315 302 289 277 269 264 251 239 226 213 LO PR 132 123 1 115 107 102 99 91 1 82 1 74 1 66 58 53 50 1 42 1 33 1 25 1 17 DZI7VSA301A*+ DV36FECC14A* OUTDOOR AMBIENT TEMPERATURE .i 1 55 1 50 1 47 1 45 1 40 1 35 1 30 1 25 1 20 1 17 1 15 1 10 MBh 36.3 34.1 31.9 29.8 28.4 27.4 24.9 26.6 24.5 23.0 21.9 21.3 20.5 18.5 16.4 14.1 12.2 T/R 32 30 29 27 26 25 23 24 22 21 20 19 19 17 15 13 11 kW 2.57 2.51 2.46 2.41 2.38 2.36 2.30 2.54 2.46 2.39 2.31 2.27 2.24 2.16 2.07 1.91 1.84 Amps 9.6 9.3 9.1 8.9 8.7 8.6 8.4 9.4 9.1 8.8 8.4 8.2 8.1 7.8 7.4 6.7 6.4 COP 4.14 3.97 3.80 3.62 3.50 3.41 3.17 3.07 2.92 2.82 2.77 2.75 2.68 2.51 2.32 2.16 1.94 HI PR 366 354 342 330 323 318 306 297 285 273 261 254 249 237 226 210 198 LO PR 126 118 110 102 97 94 86 76 68 61 53 49 46 38 31 24 16 DZI7VSA361A*+ DV36FECC14A* OUTDOOR AMBIENT TEMPERATURE 65 i 55 1 50 1 47 1 45 1 40 1 35 1 30 1 25 1 20 MBh 43.2 40.7 38.2 35.8 34.2 33.1 30.3 29.0 27.1 25.6 24.5 23.9 23.2 21.2 18.9 16.5 14.7 T/R 31 29 28 26 25 24 22 21 20 19 18 18 17 16 14 12 11 kW 3.31 3.24 3.16 3.08 3.04 3.01 2.93 2.84 2.77 2.71 2.65 2.61 2.58 2.52 2.39 2.23 2.17 Amps 12.4 12.1 11.7 11.4 11.2 11.1 10.7 10.3 10.1 9.8 9.5 9.3 9.2 8.9 8.4 7.7 7.5 COP 3.82 3.68 3.54 3.40 3.30 3.22 3.03 2.99 2.86 2.76 2.71 2.69 2.63 2.47 2.31 2.18 1.99 HI PR 368 356 344 332 325 320 308 288 276 265 253 246 242 230 221 205 194 LO PR 119 112 105 1 97 93 90 82 75 68 60 53 48 45 38 31 23 16 Calculations are based on 70 °F indoor dry bulb. Amps = Outdoor unit amps (comp.+fan) High pressure is measured at the suction service valve (the larger valve). Low pressure is measured at the gauge port connection Note: Shaded area is AHRI Rating Conditions at 477 outdoor ambient temperature 18 www.daikincomfort.com SS-DZ17VSA EXPANDED HEATING DATA - STANDARD MODE DZI7VSA421A*+ DV48FECD14A* OUTDOOR AMBIENT MBh 50.8 47.8 44.8 41.9 40.0 33.8 28.7 22.9 19.3 16.1 38.6 35.2 42.7 39.7 37.4 35.8 34.9 T/R 34 33 31 29 28 27 25 30 28 26 25 25 24 20 16 14 11 kW 3.74 3.66 3.58 3.50 3.45 3.42 3.33 4.68 4.53 4.39 4.25 4.16 4.10 3.63 3.07 2.79 2.58 Amps 14.2 13.8 13.5 13.1 12.9 12.8 12.4 18.2 17.6 17.0 16.4 16.0 15.7 13.7 11.3 10.0 9.1 COP 3.98 3.83 3.67 3.51 3.40 3.31 3.10 2.68 2.57 2.50 2.47 2.46 2.41 2.32 2.19 2.03 1.83 HI PR 377 365 353 340 333 328 316 331 318 304 291 283 278 258 235 219 203 LO PR 129 121 113 105 100 97 89 74 67 60 52 48 45 38 31 24 16 DZI7VSA481A*+ DV48FECD14A* OUTDOOR AMBIENT TEMPERATURE 65 .0 MBh 57.4 54.1 50.8 47.6 45.5 44.0 40.3 44.4 41.1 38.6 36.8 35.8 34.6 29.1 23.3 19.8 16.7 T/R 37 35 33 32 31 30 27 30 27 26 25 24 23 19 16 14 12 kW 4.73 4.61 4.49 4.37 4.30 4.25 4.14 4.69 4.54 4.39 4.24 4.15 4.09 3.62 3.06 2.80 2.60 Amps 18.4 17.9 17.3 16.8 16.5 16.3 15.8 18.2 17.5 16.9 16.2 15.8 15.6 13.5 11.1 10.1 9.3 COP 3.56 3.44 3.31 3.19 3.10 3.03 2.86 2.77 2.65 2.57 2.54 2.53 2.48 2.36 2.23 2.07 1.88 HI PR 388 375 363 350 342 337 325 335 321 308 294 286 280 259 236 221 207 LO PR 133 125 116 108 103 100 92 82 74 65 57 53 49 41 1 34 26 17 DZI7VSA601A*+ DV60FECD14A* OUTDOOR AMBIENT TEMPERATURE 65 .0 MBh 68.3 64.3 60.4 56.5 54.0 52.2 47.7 50.6 46.9 44.1 42.0 41.0 39.5 36.0 30.5 25.7 21.6 T/R 37 35 33 32 30 30 27 28 26 25 24 23 22 20 17 14 13 kW 5.91 5.74 5.56 5.38 5.28 5.20 5.03 5.06 4.90 4.74 4.58 4.48 4.41 4.25 3.81 3.47 3.23 Amps 23.1 22.3 21.6 20.8 20.3 20.0 19.3 19.4 18.7 18.0 17.3 16.9 16.6 15.9 13.9 12.5 11.5 COP 3.39 3.29 3.18 3.08 3.00 2.94 2.78 2.93 2.81 2.73 2.69 2.68 2.62 2.48 2.35 2.17 1.97 HI PR 394 381 368 356 348 343 330 333 319 306 292 284 279 266 246 227 212 LO PR 131 122 114 106 101 98 90 80 72 64 57 52 49 41 33 25 1 17 Calculations are based on 70 "F indoor dry bulb. Amps = Outdoor unit amps (comp.+fan) High pressure is measured at the suction service valve (the larger valve). Low pressure is measured at the gauge port connection Note: Shaded area is AHRI Rating Conditions at 47°F outdoor ambient temperature SS-DZ17VSA www.daikincomfort.com 19 PERFORMANCE DATA FOR STANDARD OPERATING MODE DZI7VSA181A* / DV24FECB14A* DESIGN SUBCOOLING @ AHRI 95°F CONDITIONS 9-11T AT 100% DEMAND 750 18,300 13,500 4,800 1,090 80' 18,100 13,700 4,400 1,162 85' 17,900 13,800 4,100 1,234 90' 17,500 13,700 3,800 1,312 00 13,500 3,600 1,390 100' 16,700 13,300 3,400 1,478 105° 16,200 13,100 3,100 1,565 110° 15,800 13,200 2,600 1,667 1150 15,300 13,200 2,100 1,769 NA Conditions @ 95" OD DB, 75' ID, 63" ID WB 95' 16,500 13,200 3,300 1,392 DZI7VSA301A* / DV36FECC14A* DESIGN SUBCOOLING @ AHRI 95"F CONDITIONS 13-15'F AT 100% DEMAND 75' 30,500 22,600 7,900 2,085 80' 30,100 22,800 7,300 2,222 850 29,700 22,900 6,800 2,358 900 29,100 22,700 6,400 2,506 950 00 1 22,400 6,000 100° 27,600 22,100 5,500 2,820 105' 26,800 21,700 5,100 2,985 110° 26,100 21,800 4,300 3,179 115' 25,400 21,800 3,600 3,373 NA Conditions @ 95° OD DB, 75° ID, 63° ID WB 95° 27,400 21,900 5,500 2,657 DZI7VSA241A*/ DV24FECB14A* DESIGN SUBCOOLING @ AHRI 95T CONDITIONS 11-13'F AT 100% DEMAND 75' 24,500 17,400 7,100 1,581 800 24,200 17,500 6,700 1,686 850 23,800 17,600 6,200 1,790 90, 23,300 17,500 5,800 1,904 :00 17,300 5,500 2,017 1000 22,200 17,100 5,100 2,144 105, 21,500 16,800 4,700 2,270 110, 20,700 16,800 3,900 2,291 115' 19,900 16,700 3,200 2,311 NA Conditions @ 95° OD DB, 75" ID, 63° ID WB 95° 22,000 16,900 5,100 2,019 DZI7VSA361A*/ DV36FECC14A* DESIGN SUBCOOLING @ AHRI 95°F CONDITIONS 13-15"F AT 100% DEMAND 75' 36,700 27,500 9,200 2,897 80° 36,300 27,700 8,600 3,085 850 35,800 27,900 7,900 3,272 90, 35,000 27,700 7,300 3,475 950 00 27,400 1 6,800 3,677 100, 33,300 27,000 6,300 3,904 105' 32,300 26,500 5,800 4,131 110, 31,100 26,600 4,500 4,117 115, 29,900 26,600 3,300 4,102 NA Conditions @ 95" OD DB, 75" ID, 63° ID WB 95" 33,000 26,700 6,300 3,681 20 www.daikincomfort.com SS-DZ17VSA PERFORMANCE DATA FOR STANDARD OPERATING MODE (CONT ) DZI7VSA421A*/ DV48FECD14A* DESIGN SUBCOOLING @ AHRI 95°F CONDITIONS 9-11°F Outdoor AT 100% DEMAND 75' 42,900 29,600 13,300 3,462 800 42,400 29,700 12,700 3,698 850 41,800 29,700 12,100 3,934 90' 40,900 29,500 11,400 4,189 100' 38,900 28,800 10,100 4,730 1050 37,800 28,400 9,400 5,015 1100 36,300 28,300 8,000 4,884 115° 34,800 28,200 6,600 4,753 TVA Conditions @ 95° OD DB, 75° ID, 63° ID WB 95° 38,600 28,600 10,000 4,449 DZI7VSA601A*/ DV60FECD14A* DESIGN SUBCOOLING @ AHRI 95°F CONDITIONS 8-10°F AT 100% DEMAND Outdoor 75° 57,900 38,200 19,700 5,047 80' 57,200 38,300 18,900 5,397 85' 56,500 38,400 18,100 5,747 90' 55,300 38,100 17,200 6,127 100° 50,100 35,600 14,500 6,109 1050 46,200 33,300 12,900 5,712 110° 41,500 31,200 10,300 5,311 115° 36,700 29,000 7,700 1 4,910 TVA Conditions @ 95° OD DB, 75° ID, 63° ID WB 95° 52,100 37,000 15,100 6,513 DZI7VSA481A*/ DV48FECD14A* DESIGN SUBCOOLING @ AHRI 95°F CONDITIONS 7-9°F AT 100% DEMAND OUTDOOR TOTAL SENSIBLE LATENT TOTAL 75' 48,800 33,200 15,600 4,252 800 48,200 33,300 14,900 4,548 850 47,600 33,300 14,300 4,843 900 46,600 33,100 13,500 5,163 95* •• 32,800 12,700 5,482 100' 44,300 32,300 12,000 5,839 1050 43,000 31,800 11,200 6,196 1100 39,100 30,000 9,100 5,573 115' 35,200 28,200 7,000 4,950 TVA CONDITIONS @ 95" OD DB, 75° ID, 63° ID WB 95° 43,900 32,000 11,900 5,488 SS-DZ17VSA www.daikincomfort.com 21 PERFORMANCE DATA FOR FIELD -SELECTABLE BOOST MODE DZI7VSA181A*/ DV24FECB14A* DESIGN SUBCOOLING @ AHRI 957 CONDITIONS 9-11°F IN BOOST MODE 75' 19,300 14,100 5,200 1,202 80° 19,100 14,100 5,000 1,283 850 18,800 14,100 4,700 1,363 90' 18,400 14,000 4,400 1,451 95, III 1 13,900 4,100 1,538 100, 17,500 13,700 3,800 1,636 1050 17,000 13,400 3,600 1,734 1100 16,600 13,500 3,100 1,849 115' 16,100 13,500 2,600 1,964 NA Conditions @ 95° OD DB, 75° ID, 63° ID WB 95, 17,400 13,600 3,800 1,540 DZI7VSA301A*/ DV36FECC14A* DESIGN SUBCOOLING @ AHRI 95°F CONDITIONS 13-15'F IN BOOST MODE 750 32,200 23,500 8,700 2,258 80' 31,800 23,600 8,200 2,409 850 31,400 23,600 7,800 2,559 90' 30,700 23,400 7,300 2,722 1 111 11 • 11 1000 29,200 22,800 6,400 3,067 105' 28,300 22,400 5,900 3,248 1100 27,600 22,500 5,100 3,462 1150 26,800 1 22,500 1 4,300 3,675 NA Conditions @ 95° OD DB, 75° ID, 63° ID WB 95° 28,900 22,500 6,400 2,888 DZI7VSA241A*/ DV24FECB14A* DESIGN SUBCOOLING @ AHRI 95°F CONDITIONS 11-13°F IN BOOST MODE OUTDOOR TOTAL SENSIBLE LATENT TOTAL 75' 25,700 18,200 7,500 1,705 800 25,400 18,300 7,100 1,820 850 25,100 18,300 6,800 1,934 900 24,600 18,200 6,400 2,058 III 18,000 1 6,000 2,182 100' 23,400 17,800 5,600 2,320 1050 22,700 17,500 5,200 2,458 1100 21,300 17,100 4,200 2,385 115' 19,900 16,700 3,200 2,311 NA Conditions @ 95° OD DB, 75° ID, 63° ID WB 95° 23,100 17,600 5,500 2,184 DZI7VSA361A*/ DV36FECC14A* DESIGN SUBCOOLING @ AHRI 95°F CONDITIONS 13-15°F IN BOOST MODE 75° 38,600 28,600 10,000 3,074 80' 38,200 28,800 9,400 3,276 850 37,700 29,000 8,700 3,477 90' 36,900 28,700 8,200 3,695 . III •11 .11 1000 35,000 28,000 7,000 4,157 105' 34,000 27,500 6,500 4,400 110' 32,000 27,100 4,900 4,251 115' 29,900 1 26,600 1 3,300 4,102 NA Conditions @ 95° OD DB, 75° ID, 63° ID WB 95, 34,700 27,800 6,900 3,917 22 www.daikincomfort.com SS-DZ17VSA PERFORMANCE DATA FOR FIELD -SELECTABLE BOOST MODE (CONT.) DZI7VSA421A*/ DV48FECD14A* DESIGN SUBCOOLING @ AHRI 95°F CONDITIONS 9-11°F Outdoor IN BOOST MODE 75' 45,000 30,600 14,400 3,669 800 44,500 30,700 13,800 3,921 850 43,900 30,700 13,200 4,173 900 43,000 30,500 12,500 4,446 95* 0•0 30,200 11,800 4,719 100, 40,900 29,800 11,100 5,024 1050 39,700 29,400 10,300 5,329 1100 37,300 28,800 8,500 5,041 115° 34,800 28,200 6,600 4,753 TVA Conditions @ 95° OD DB, 75° ID, 63° ID WB 95° 40,500 29,600 10,900 4,724 DZI7VSA601A*/ DV60FECD14A* DESIGN SUBCOOLING @ AHRI 95°F CONDITIONS 8-10°F IN BOOST MODE Outdoor 75° 61,100 39,700 21,400 5,650 80' 60,400 40,100 20,300 6,048 85' 59,600 40,500 19,100 6,446 90' 58,300 40,200 18,100 6,877 100° 51,600 36,600 15,000 6,510 1050 46,200 33,300 12,900 5,712 110° 41,500 31,200 10,300 5,311 115° 36,700 29,000 7,700 1 4,910 TVA Conditions @ 95° OD DB, 75° ID, 63° ID WB 95° 55,000 38,500 16,500 7,316 DZI7VSA481A*/ DV48FECD14A* DESIGN SUBCOOLING @ AHRI 95°F CONDITIONS 7-9°F IN BOOST MODE OUTDOOR TOTAL SENSIBLE LATENT TOTAL 75' 51,500 33,000 18,500 4,758 800 50,900 33,100 17,800 5,093 850 50,200 33,100 17,100 5,428 900 49,100 32,900 16,200 5,791 ••• 32,600 15,400 6,154 100, 45,500 32,200 13,300 6,175 1050 43,000 31,800 11,200 6,196 110' 39,100 30,000 9,100 5,573 115' 35,200 28,200 7,000 4,950 TVA CONDITIONS @ 95° OD DB, 75° ID, 63° ID WB 95° 46,300 31,900 14,400 6,161 SS-DZ17VSA www.daikincomfort.com 23 SOUND POWER LEVELS COOLING MODE OCTAVE BAND SPECTRUM FREQUENCY.: Minimum 55 40.5 46.5 50.4 49.9 41.1 37.4 45.4 1.5-ton Intermediate 58 44.0 46.3 50.6 55.5 42.7 39.4 45.3 Maximum 66 51.7 60.6 61.3 59.4 55.2 48.3 49.0 Minimum 55 40.5 46.5 50.4 49.9 41.1 37.4 45.4 2-ton Intermediate 59 51.2 48.7 54.6 52.8 46.3 41.9 46.8 Maximum 67 55.3 60.4 62.5 60.9 56.0 50.7 47.4 Minimum 57 48.2 47.5 53.3 50.9 45.8 37.3 26.3 2.5-ton Intermediate 60 54.7 52.3 55.1 51.3 47.1 43.9 33.4 Maximum 68 56.4 60.0 62.9 63.1 58.2 53.3 44.7 Minimum 57 48.2 47.5 53.3 50.9 45.8 37.3 26.3 3-ton Intermediate 60 56.1 51.0 54.2 50.9 47.6 43.2 33.5 Maximum 68 58.0 59.2 62.9 62.7 58.7 53.9 44.5 Minimum 61 50.9 52.8 54.5 54.5 55.6 49.4 38.5 3.5-ton Intermediate 65 51.0 56.1 59.6 60.1 56.6 53.7 42.0 Maximum 72 58.1 64.4 65.0 67.8 63.4 60.5 47.9 Minimum 61 50.9 52.8 54.5 54.5 55.6 49.4 38.5 4-ton Intermediate 65 53.5 55.4 59.5 60.3 56.8 54.4 41.9 Maximum 72 59.0 62.7 65.0 67.9 64.4 59.9 48.5 Minimum 61 50.8 55.7 54.7 55.4 49.5 44.2 41.5 5-ton Intermediate 66 53.6 61.6 59.5 59.8 55.4 49.7 46.7 Maximum 74 61.7 66.1 66.9 69.7 66.0 59.9 56.0 HEATING MODE OCTAVE BAND SPECTRUM FREQUENCY.: Minimum 57 42.4 48.4 52.3 51.9 44.3 39.3 47.4 1.5-ton Intermediate 60 44.6 48.6 52.8 57.8 45.0 42.8 47.5 Maximum 68 51.9 62.6 63.3 61.5 57.2 51.7 50.9 Minimum 57 42.4 48.4 52.3 51.9 44.3 39.3 47.4 2-ton Intermediate 61 53.0 50.7 56.6 54.8 49.7 43.9 48.8 Maximum 69 57.1 62.3 64.4 62.7 59.5 52.5 49.2 Minimum 59 48.4 50.8 55.3 52.9 47.8 39.3 28.4 2.5-ton Intermediate 62 56.7 54.3 57.1 53.3 49.1 45.9 35.4 Maximum 70 58.4 62.0 64.9 65.1 60.2 55.3 46.7 Minimum 59 48.4 50.8 55.3 52.9 47.8 39.3 28.4 3-ton Intermediate 62 56.7 54.9 56.6 53.3 50.0 45.6 35.9 Maximum 70 57.8 62.7 64.8 64.6 60.6 55.8 46.4 Minimum 63 51.2 54.7 56.3 56.4 57.5 51.3 40.4 3.5-ton Intermediate 67 53.0 58.1 61.6 62.1 58.6 55.7 44.0 Maximum 74 60.1 66.4 67.0 69.8 65.4 62.5 49.9 Minimum 63 52.5 54.6 56.2 56.3 57.4 51.2 40.3 4-ton Intermediate 67 55.1 57.2 61.3 62.1 58.7 56.3 43.7 Maximum 74 60.8 64.7 67.0 70.0 66.4 61.9 50.5 Minimum 63 54.8 57.4 56.4 57.1 51.2 45.9 42.9 5-ton Intermediate 68 57.8 63.4 61.2 61.6 57.2 51.5 48.0 Maximum 76 62.7 66.7 69.0 71.9 68.4 63.9 54.7 24 www.daikincomfort.com SS-DZ17VSA AHRI ALL AHRI SYSTEM RATINGS ARE ACCESSIBLE IN THE UNITARY MATCHUP TOOL VIA DAIKIN CITY OR IN THE DAIKIN SYSTEM CONFIGURATOR TOOL VIA PARTNERUNK. SS-DZ17VSA www.daikincomfort.com 25 DIMENSIONS 8 7 6 5 4 3 2 1 ECN PEY iONE DESORPTION CFK DR DATE rILt0001 A qp(a INfYLPE tart E DIMENSIONS E D D 0 k C = = C B B Daikin Manufacturing Company LLC A DZ17VSA A al SPEORL 04AWTOMICS owsxowrcwu,ssKonMDcx. &SOOMWTOrawwa.csttrar+ OMO+NWK401"WMWsw srxortmroxnr.rmxorwsl area r �irc ®, 6SDAA ®=tliIm& ORORACTFAmc ®=SI(71FlGWTOIPRAOI rTc wlsu[rrtwmaxarccsna CeefWNl4xFACIWGNWM.IF rqr ro ecasnossora onascatn.aauaoran rlxweosc O�, A rxcwr ASAVlwwauxxmrn uun eslxrwmuvx oowuaxcaamortai axoutaeanmwsoss roxxxxrtrASlArvr. 8 7 6 5 4 3 �u.2 1 MODEL W�� Dry Hr� DZI7VSA181** 36% 13% 27% DZI7VSA241** 36% 13% 27% DZI7VSA301** 36% 13% 27% DZI7VSA361** 36%e 13% 27% DZI7VSA421** 37 12% 39 DZI7VSA481** 37 12% 39 DZI7VSA601** 37 12%39 26 www.daikincomfort.com SS-DZI7VSA Q v 77 0 3 0 0 0 91 N A1P PRINTED CIRCUIT BOARD ELECT---- WIRING DIAGRAM POSITIONIOFCELEMENTS ASSEMBLY BSI PRINTED CIRCUIT BOARD SERVICE POWER SUPPLY BSl—BS3 PUSH BUTTON SWITCH A2P 1 L2-'�-�_� Y1S X1M C1 CAPACITOR 208/230V A1Pg'111 DS1 DS2 DIP SWITCH 60Hz Ll- X1M L1L2 O R1T R2T R3T R4T R5T R6T BLK RED NOTE6. NOTE7. A2P F1U FUSE Z2C N=4 X28A X29A t° t° t° t° t° t° A2P F2U FUSE AlP Ll L2 o F6U FUSE HIP HIP-M PILOT LAMP SERVICE MONITOR -RED X25A X11A X12A X13A o 5 0 FBI FBI HAP, HAP-M FLASHING LAMP F1U X21A r YIE H2P,H2P-M (SERVICE MONITOR -GREEN) SEG1 SEG2 SEG3 K11M MAGNETIC CONTACTOR K2R,K4R MAGNETIC RELAY o ❑°❑ ❑° K5R, K10R F2U X52A-M 5 BS1 BS2 BS3 L1R POWER CONDITIONER GRN E1 K2R K4R K5R DS2 o M1C MOTOR COMPRESSOR Z1F BLK NOTE5. -- UFF NOTE2. $ M1F MOTOR FAN __ PS SWITCHING POWER SUPPLY _ Xs51A Ro GRY 1 2 X5A-A o Q1E OVERLOAD PROTECTOR Ps c o ° R2 R3 RESISTOR INDOOR UNIT OR X52A-S X52A ° z2F ® THERMOSTAT o o R1T THERMISTOR AMBIENT R7T ,t° o R2T THERMISTOR DISCHARGE HAP-M HIP-M H2P-M S1NPH/L ° R3T THERMISTOR LIQUID K10R K11M DS1 X17A o o X72A R4T THERMISTOR DEFROST OFF 19 NOTE2. NOTE8. o H2P R5T THERMISTOR COIL CIRCUIT L1R A- V2R 1 2 X32A P> rib]o HIP X71A R6T THERMISTOR SUCTION 0 o R1T PTC THERMISTOR WHT HR1 + — S1PH o -& X73A SEGI—SEG3 1-SEGMENT DISPLAY A2P BRN HR3 X41A-M 5 X41A-S 0 HAP S1NPH L PRESSURE SENSOR HIGH LOW S1PH PRESSURE SWITCH HIGH PPL HR4 V1T R V1D V2D DIODE RED HR2 V2T X73A-M V1T V2T IGBT V1R V3R IGBT POWER MODULE Z3C V2D ffl X71A-M V211 IDIODE BRIDGE N-6 + C1 X1M TERMINAL BLOCK X72A-M X41A RAM MONITOR X52A CONNECTOR SHARE DATA o Y1E ELECTRONIC EXPANSION VALVE COIL F6U a Y1S REVERSING VALVE COIL THE POSITION OF °% 18 Z1C—Z3C FERRITE CORE COMPRESSOR R2 R3 X5A °o Z1F Z2F NOISE FILTER + — + — ° NOTE 1. � :TERMINAL 3. SYMBOLS SHOWS AS FOLLOWS BLK:BLACK RED:RED THRMENTRANCE �K V1R �K V3R o m :TERMINAL BLOCK WHT:WHITE YLW:YELLOW GRN:GREEN BRN:BROWN PPL:PURPLE OF WIRE CONNECTOR 4. USE COPPER CONDUCTORS ONLY. U V W X1o8A X33A :FIELD WIRING 5. CLASS 2 WIRE. Z1C N=5 :NOISELESS GROUND 6. THIS CONNECTOR IS FOR CONNECTING U :PROTECTIVE GROUND THE COMPRESSOR CRANKCASE HEATER V BLK RED YLW 2. THE POSITIONS OF THE (OPTIONAL ACCESSORIES). U V W SELECTOR SWITCHES(DS1,DS2) 1. THIS CONNECTOR IS FOR CONNECTING W MS MS INDICATE FACTORY SETTING. THE DRAIN PAN HEATER M1C 3— M1F 3— DIE REFER TO THE SERVICE (OPTIONAL ACCESSORIES). NOTE8. MANUAL IN DETAIL. 8. WHEN OPERATING,DO NOT SHORT CIRCUIT FOR PROTECTION DEVICE(S1PH AND 01E). Wiring is subject to change. Always High 1/oilage: Disconnect all power before servicing or installing this unit. Multiple power refer to the wiring diagram on the 1 % WARNING sources may be present. Failure to do so may cause property damage, personal injury, or death. unit for the most up-to-date wiring. im N 00 Q 0 3 0 0 3 Ln 0 N D POWER SUPPLY 08/230V 60HZ LI % X1M L1 L20 BLK RED Z1C N=2 Z2C N=6 Al P L1 L2 X25A F1U GRN[E3 WIRING DIAGRAM RI TT R�2T R�3T R�4T R�5T R�6T X28A X29A Lt° J Lt°J Lt. [ t° [ t° [ t° GRN E1 1- K2R K4R K5R --Z1F�� F31 U THE POSITION OF K10R COMPRESSOR R9T TERMINAL K11 M +t° THE ENTRANCE OF WIRE Aq- V1R U i PFC NV - W Cl IN THE CASE OF + DZIIVSA421AA, 481AA E3 THE ENTRANCE R2 R3 OF WIRE + + �K V2R �K U U V W V Z3C N=5 W BLK RED YLW IN THE CASE OF u v w DZ17VSA601 AA M1 C Ms Mirk Ms X11A 08A X12A X13A B] [B� X21A SEG1 SEG2 SEG3 X851A L El ❑ ❑ CCC BSI BS2 BS3 DS2 ON OFF" NOTE2. X17A 12 X32A HAP HIP H2P DS1 ON L n NOTE2. OFF 12 0 X41A 0 0 OIE 1TFf 0 X52A o 0 0 X33A NOTE5. ELECTRONIC COMPONENT ASSEMBLY POSITION OF ELEMENTS. A1P X1M 0 IY1 E INDOOR UNIT OR THERMOSTAT SINPH/L NOTES. tQL___E Z4C S1PH N=1 IHAP,H2P ((SERVICE MONITOR -GREEN) K11M IMAGNETIC CONTACTOR IkYAk9mIkia&10] NOTE 1. -0- :TERMINAL Kul InCICIn1Jl1JP m :TERMINAL BLOCK RIST THERM1ST01 °O :CONNECTOR R9T PTC THERM _lt= :FIELD WIRING SEGI-SEG3 1-SEGMENT :NOISELESS GROUND S1NPH L PRESSURE ® :PROTECTIVE GROUND S1PH PRESSURE 2. THE POSITIONS OF THE SELECTOR V1R DIODE BRIT SWITCHES(DS1,DS2) INDICATE V2R V3R 1GBT POWEI FACTORY SETTING. X1M TERMINAL REFER TO THE SERVICE MANUAL X41A RAM MON1T IN DETAIL. X52A CONNECTOR 3. SYMBOLS SHOWS AS FOLLOWS Y1E ELECTRONIC I BLK:BLACK RED:RED YLW:YELLOW Y1S REVERSING GRY:GRAY GRN:GREEN Z1C-Z4C FERRITE C 4. USE COPPER CONDUCTORS ONLY. Z1F NOISE FIL 5. CLASS 2 WIRE. 6. THIS CONNECTOR IS FOR CONNECTING THE COMPRESSOR CRANKCASE HEATER(OPTIONAL ACCESSORIES). 1. THIS CONNECTOR IS FOR CONNECTING THE DRAIN PAN HEATER(OPTIONAL ACCESSORIES). 8. DURING OPERATION , DO NOT PUT SHORT CIRCUIT WIRE FOR PROTECTION OFVICF(S1PH AND 01F) Wiring is subject to change. Always M h 1/ Disconnect all L refer to the wiring diagram on the I � oltage: power before servicing or installing this unit. Multiple power J 0 WARNING sources may be present. Failure to do so may cause property damage, personal injury, or death. unit for the most up-to-date wiring. ACCESSORIES MODEL DESCRIPTION Air Direction Adjustment Grill DZ17VSA 0181A* DZ17VSA 0241A* DZ17VSA 0301A* DZ17VSA 0361A* DZ17VSA 0421A* DZ17VSA 0481A* DZ17VSA 0601A* Drain Pan Heater Drain Pan Heater SS-DZ17VSA www.daikincomfort.com 29 NOTES 30 www.daikincomfort.com SS-DZ17VSA NOTES SS-DZ17VSA www.daikincomfort.com 31 NOTES Our continuing commitment to quality products may mean a change in specifications without notice. 02020 OA/K/NMANUFACTUR/NGCOMPANY.. L.P. • Houston, Texas • Printed in the USA. 32 www.daikincomfort.com SS-DZ17VSA