Loading...
FIR2020-0036vv FIRE SPRINKLER Permit City of Edmonds Ave• • r • ' 1 1 • ' ' " • www.edmondswa.gov425.771.0220 Type: FIRE SPRINKLER Owner/ Business: GURSLI FAMILY LP Status: ISSUED Subtype: FIRE SPRINKLER NEW - COM Parcel No: 00463303200303 Site Address: 8509 244TH ST SW BLDG 1 EDMONDS,WA 98026- Applied: 3/13/2020 9068 Subdivision: 008454, 004633, 006781, 006680, 008120 Lot: 0 Issued: 4/29/2020 Fire Sprinklers: Lot Area: Zoning: Final: Valuation: $27,000.00 Occupancy Type: Construction Type: Expiration Date: 4/24/2021 Code Edition: 0 No. Stories: 0 # of Dwelling Units: 0 Issued by: JOK Scope of Work: NYLAND- WET FIRE SPRINKLER SYSTEM WA State Contractor L & I #: MOOREFP116NP City of Edmonds Business License #: 602454996-001-0001 CONTACTS NAME TYPE NAME ADDRESS PHONE EMAIL APPLICANT MOORE FIRE PROTECTION 18621 SE MAY VALLEY Rq (425)271-5598 MATTHEW@MOOREFIRE.COM ISSAQUAH WA 98027 CONTRACTOR MOORE FIRE PROTECTION 18621 SE MAY VALLEY RR (425)271-5598 MATTHEW@MOOREFIRE.COM ISSAQUAH WA 98027 OWNER GURSLI FAMILY LP 8509 244TH ST SW, EDM0NDS WA 98026-9068 FEE INFORMATION DESCRIPTION ACCOUNT AMOUNT PAID PAID DATE RECEIPT # CITY TECHNOLOGY FEE CHARGED PER PERMIT 001.000.321.99.100.00 $40.00 $40.00 3/31/20 R4642 FIRE SPRINKLER - NEW COM FIRE PLAN REVIEW FEE 001.000.345.83.100.00 $513.40 $513.40 3/13/20 R4458 FIRE SPRINKLER - NEW COM FIRE VALUE BASED FEE 001.000.342.40.000.00 $604.00 $604.00 3/31/20 R4642 FIRE SPRINKLER - SUB NEW COM BLDG PERMIT FEE 001.000.322.10.000.00 $100.00 $100.00 3/31/20 R4642 FIRE SPRINKLER - SUB NEW COM ENG REVIEW FEE 001.000.341.82.000.00 $100.00 $100.00 3/31/20 R4642 FIRE SPRINKLER - SUB NEW COM FIRE INSP FEE 001.000.345.83.100.00 $100.00 $100.00 3/31/20 R4642 TOTALS: $1,4S7.40 $1,457.40 CONDITIONS CONDITION TYPE STATUS NOTES Printed: Wednesday, April 29, 2020 11:00:34 AM 1 of 2 N N �i ALL BUILDING PERMITS SEQID I INSPECTION TYPE 1- HOLD HARMLESS - Applicant on behalf of his or her spouse heirs assigns and successors in interests, agrees to indemnify defend and hold harmless the City of Edmonds, Washington, its officials, employees, and agents from any and all claims for damages of whatever nature, arising directly or indirectly from the issuance of this permit. Issuance of this permit shall not be deemed to modify, waive or reduce any requirements of any City ordinance nor limit in any way the City's ability to enforce any ordinance provision. 2 - PERMIT DISCLOSURE - Any request for alternate design, modification, variance or other administrative deviation from adopted codes ordinances or policies must be specifically FOR requested in writing and be called out and identified. Processing fees for such requests INFORMATION shall be established by Council and shall be paid upon submittal and are nonrefundable. 3 - SOUND OR NOISE - Sound/Noise originating from temporary construction sites as a result of construction activity are exempt from the noise limits of ECC Chapter 5.30 only during the hours of 7:00am to 6:00pm on weekdays and 10:00am to 6:00pm on Saturdays, excluding Sundays and Federal Holidays. At all other times the noise originating from construction sites/activities must comply with the noise limits of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120.4 - OCCUPANCY - Final approval on a project or final occupancy approval must be granted by the Building Official prior to use or occupancy of the building or structure. Check the job card for all required City inspections including final project approval and final occupancy inspections. F-5 FIRE SPRINKLER ACCEPT F-6 FIRE BUCKET TEST F-7 FIRE PRESSURE TEST F-8 FIRE SPRINKLER INSUL X-1 FIRE FINAL" X-0 CROSS CONNECTION FINAL INSPECTOR COMPLETED I RESULT DATE NOTES Printed: Wednesday, April 29, 2020 11:00:34 AM 2 of 2 CITY OF EDMONDS 121 5T" AVENUE NORTH • EDMONDS, WA 98020 • 425.771.0220 • FAX 425.771,0221 Website: www.edmondswa.gov DEVELOPMENT SERVICES DEPARTMENT Planning • Building • Engineering • Fire ♦ ?C. 1 A9. APPLIED DATE: 3/13/2020 APPLICATION #: FIR2020-0036 PROJECT ADDRESS: 8509 244TH ST SW BLDG 1 WORK DESCRIPTION: NYLAND- WET FIRE SPRINKLER SYSTEM APPLICANT: MOORE FIRE PROTECTION OWNER/BUSINESS: GURSLI FAMILY LP OUTSTANDING ITEMS AT TIME OF SUBMITTAL: Your Permit Coordinator/ contact person is: DENISE NELSON Denise Nelson - Denise.Nelson@edmondswa.gov Christina Wayland - Christina.Wayland@edmondswa.gov Kristin Johns - Kristin.Johns@edmondswa.gov PROCESS INFORMATION: After each of the appropriate departments have reviewed your application an email will be sent to notify you of either 1) Permit is ready to issue with balance due or 2) Attached comments/corrections are to be submitted for additional review. If there are comments/corrections to be made please submit 2 corrected sets of plans and any other documentation to Development Services. A response letter is required for each reviewing department with comments. The preferred method of inquiries is via email to your Permit Coordinator Development Services Hours: Monday & Tuesday 8:00 AM — 4:30 PM WEDNESDAY— OPEN 8:30 TO NOON Thursday & Friday 8:00 AM — 4:30 PM • Incorporated August 11, 1890 • Sister City - Hekinan, Japan BUILDING PERMIT APPLICATION Development Services Building Division 121 5th Ave N / Edmonds, WA 98020 ' n c. 189" 425.771.0220 For handouts, submittal requirements, permit status and inspection scheduling information go to: www.edmondswa.gov. PLEASE NOTE: Intake appointments are required for New Single Family Residences, Large Additions, ADU's, New Commercial, and Major Tenant Improvement application submittals. If plans are prepared by a profession- al, electronic files are requested in addition to the hard copies. Please bring electronic files on a flash drive or coordinate for electronic transfer. Please call 425-771-0220 to schedule an intake appointment! JOB SITE INFORMATION/LOCATION: (Where the work is taking place) Job Site Address: 8509 - 244th SW BLDG 1 Parcel: 00463303200303 Lot /Unit/Suite #: Subdivision: PROPERTY OWNER: Name: Roy Gursll Mailing Address: 5909 - 164th St SW city/state/zip: Lynnwood, WA 98037 Phone #: 425-210-5502 Email OWNER INSTALLATION: *If yes, read and sign* Will work be performed by the property owner? ❑ Yes ® No I own, reside in, or will reside in the completed structure. This installation is being made on property that I own which is not intended for sale, lease, rent, or exchange according to RCW 18.27.090. Owner Signature: APPLICANT / CONTACT INFORMATION: Name of Applicant: Mailing Address: 14401 Issaquah -Hobart Rd SE City/state/zip: Issaquah, WA 98027 Phone #: 425-891-3863 E-mail: matthew@moorefire.com GENERAL CONTRACTOR: (If different from applicant) General Contractor: Greenwalk Development, LLC Mailing Address:28720 SE 63rd St city/state/zip: Issaquah, WA 98027 Phone #: 425-773-0797 E-mail: kristaiverson8l@hotmail.com STATE UBI #: 601-191-141 CITY OF EDMONDS BUSINESS LICENSE #: NR-022716 WA STATE CONTRACTOR L & 1 M (CCB) & EXPIRATION DATE: MOOREFP116NP 8/26/21 Office Use Only TYPE OF PERMIT (Provide Details ❑ Accessory Structure/ ❑ Addition Detached Garage ❑ Demolition ❑ Mechanical ❑ New Single Family / Duplex ❑ Plumbing X Fire Sprinkler ❑ Remodel ❑ New Commercial/ Mixed Use ❑ Re -Roof ❑ Signs ❑ Tank ❑ Tenant Improvement ❑ Other Remodel Permit fees are based on: The value of the work performed. Indicate the value (rounded to the nearest dollar) of all equipment, materials, labor, overhead, and the profit for the work indicated on this application. Valuation. $27,000 PROPOSED NEW SQUARE FOOTAGE FOR THIS APPLICATION Basement sq ft: Finished ❑ Unfinished ❑ 1st Floor, sq ft: 2nd Floor, sq ft: Garage/Carport:, sq ft: Deck/Covered Porch/Patio: Other sq ft: PROJECTDESCRIPTION Install wet automatic fire sprinkler systems in each new apartment building. Each system will have a separate tap from the water main. I i I certify that the information I have provided on this form/application is true, correct and complete, and that I am the property owner or duly authorized agent of the property owner to submit a permit application to the City of Edmonds. Print Name: Matthew Steele Signature: ��L�.tj- 151&d111 Date 3/4/20 COMMERCIALGENERAL DATA Occupancy Group(s): Occupant Load(s): Type(s) of Construction: Fire Sprinklers: Yes ❑ No ❑ WA STATE ENERGY CODE: If your project affects the building envelope, mechanical systems, and/or lighting, you must complete the appropriate WSEC forms. DEFERRED SUBMITTALS: All commercial building permits that will require associated plumbing, mechanical, fire sprinkler, and/or fire alarm permits are applied for separately. TI / CHANGE OF USE / NEW BLDG: Include TRAFFIC IMPACT worksheet EQUIPMENTMECHANICAL • BTUs Gas / Elec / Other Qty A/C Unit /Compressor Air Handler /VAV Boiler Dryer Duct Exhaust Fans Fireplace Furnace Heat Pump Unit Hydronic Heating Roof Top Unit (Provide eleva- tions if a Commercial Bldg) Other: COUNTSPLUMBING FIXTURE Qty Qty Clothes Washer Tub/ Showers Dishwasher Backflow Device (RPBA, DCDA, AVB) Drinking Fountain Pressure Reduction/ Regulator Valve Floor Drain/Sink Refrigerator Water Supply Hose Bibs Water Heater - Tankless? Y or N Hydronic Heat Water Service Line Sinks Other: Fire Sprinklers 244 Toilets other: Fire Sprinkler Risers 2 GAS/FUEL CONNECTION COUNTS (New, Relocated or re -piped) BTUs Qty BTUs Qty A/C Unit Outdoor BBQ/ Fire pit Boiler Stove/Range/Oven Dryer Water Heater Fireplace/ Insert Other: Furnace Other: MEDICAL• .. .. Qty Qty Carbon Dioxide Nitrous Oxide Helium Oxygen Medical Air Other: Medical - Surgical Vacuum Other: DEMOLITION Type of structure to be demolished: Square footage of structure to be demolished: AHERA Survey done? Y / N PSCAA Case #: Critical Areas Determination: Study Required ❑ Conditional Waiver ❑ Waiver ❑ Fill in Place ❑ Fill Material: Removal ❑ TS,of Tank (Gallons) Critical Areas Determination: Study Required ❑ Conditional Waiver ❑ Waiver ❑ .• Grading: Cut cubic yards Fill cubic yards Cut / Fill in Critical Area: Yes ❑ No ❑ GENERAL PROVISIONS APPLICATIONS: Applications are valid for a maximum of 1 year. ESLHA Applications, 2 years. LICENSING: All contractors and subcontractors are required to be licensed with Washington State Department of Labor & Industries and have a current City of Edmonds Business License. IpalA AlE ORM k Na+M ROSM 5r. ..______ ____ _____ _____ __ _____ N .AM Si. SE,F'- eA.60 I IX. ,0' SE1WR FASF1)FNI I I •11 111 AM/ tt0]03025). X0� PIPE 1 1 fE �)gNA1M. f]L SEN£R W IW= ..zRJ 1 [SYi. i0 • FFtINILII PROJECT TEAM � w _ - f _. C GLJ- 14 SOR) SISi -NUEWA SM CW)Kr: 51CK 84ME5 2 pPMEGUZxu, PE wN : 0%) Sw-m U E 1 � A � a. -- - - --`-'- - - - � •---_�_---- - ---- - - - -- - - -- - - R1°NF' 21IS) 9R3-aA0 rO < 00 ' R w._ -r .-_ ___ -- -- L ... N16 - _. '1_ -_ Ex+NL wOo•WrPrWmP„iWi4wP mom AIWP.BIRi 0.1EA@I4l K �pni NQUECL wrt a I - I Y croxE ux)mEcnww amour 1xwE HRs) azJ-)m1 ^7 nEPaRi wrEn its n. zmo! 333 or .. - LOX 52K BeBEs nlwE : (zas)eae-woo 1� i c3 •� r„ r BUILDING 1 PO - d a xwx W rw. -= 10 UNITS 6EaraARr �WMIR 0 ea n oea I 2ND FLOOR FF= 457 00 I it 7- 1ST FLOOR FF= 447.00 o a L 01 it _ '' I I I --- -T- I .r �I I I i I m 8{SIm2 9TL 5Yl A iI�L"J I I I I a ARCEL 00463.H132C0102 (D N (f I I - -- _ s,__ _ p a. 10'SEwA CD BUILDING2 i --- --EMz�n"Pua wL°i -1 -- -- _ "j o 9M205. Z oo 9 UNITS + OFFICE i t Q w �� _ aM7 T. BE Q 11J 2ND FLOOR FF= 467.33: i z - - W By owro. o 1ST FLOOR FF=448.001 I w� uao�wEo 18m Ex ulu ` 0 1 1 I rfLl wW u• WArq xE I'M In o l it --------- PER s¢Tz-IN mow '•Its 0W Ps0 U c) c � -�o II PCA�i I i_ YIS .£ � ` � `�. � Z Q O U)1 1 4 Ex =1 I r T—v•TIES (BY PSE) .. 1 { YOw MixlIN -LwxutR Q 'a — -- — J N ■ A0WE0 Bonn ■ z A+Woo w3 •_._._____-ice--- _ - • .a N 89"07'04" W 125.14 1 LEGEND a�v"`wLo .'kr�E w°�vm'c M2 Dos NG PROPOSED W rv1u¢ 4 NYt Im ---- —11TY WE N 00'52'56- E ' may -- R,DW. L4Nr NE EX. CONDOMINIUM (WINDCREST) 20.00 8515 244TH ST. SW % m PARCELS 00845400-100100 TO-200500 KW r WpwRa wa -E---'---- y ^^ WNE .... _ I J Z o _,m_ a 0„0� GOVERNING AGENCIES N_69'1Y7:Da" w 60.00 Q F 4' T. _ •- — wArzR Mux stxER xuN SITE. GRADING. STORMWAIER ELECTRIC DL URurr PILE 4., Ir 0 CITY OF EDMONDS SNOHOMISH COUNTY PUD NO. 1 To RE Iw CCI a - - - srORN URA• 121 STH AVENUE NORTH CONTACT: MARY MCALUSTER S 00'S2'59" w I F- tY • J1RE xroRANr EDMONDS, WA 98020 PHONE: (425) 670- 3216 5.00 w ® + *,iB 7WATE . SEMR NATURAL GAS S 89'07'04" E 40.00 4A — —_-' a, A °Ah vuW OLYMPIA VIEW WATER h SEWER DISTRICT PUGET SOUND ENERGY M SEWER EAME l ~ W • EE'IER x� OE 8128 228TH STREET SW 1 K 0 wesz0s � z PHONE: (888) 321-7779 NOTE O • smrN w EDMONDS. WA 98026 'I a 40' Q' rn i SaE MMXILF CONTACT: LYNNE DAN:ELSON TELEPHONE Etp Op QM OeMC„ oa; rc�m°�„•rn" 4 • / I �Aarsk irA 20-RENSEDWATER SERVICE w w 5 PHONE: (425) 774-7769 FRONTIER uw �aewa aw.10eo,u / I,utMtt ESIr CAW B. TDW -- EIECRIX LINE CONTACT* PERMIT: BL020170698J0900 E CONTACT: JLTIEMY fALLT aro.Wm.cm. „ a I APPROVED FOR CONSTRUCTION r PXa1E UNE FIRE PHONE: (425) 263-4024 µ':"me° a °W w� u�aiµo wwax a 11 '� ---.-- —c— cue OTY OF EDMONDS UNE SOUTH SNOHOMISH COUNTY FIRE & RESCUE FP'. r-p 1 rows —T CONTACT: KEAN ZWEBER CABLE wr.x°Nl m�smc lmmaeo a u °4°.mWer'ml ` p I+ {F `Fj1I M a ► uwnrttE PHONE: (425) 771-0213 COMCAST CALL AT LEAST 2 WORKING )- •`�%--- *' " T w CONTACT: MIKE FONTENOT DAYS BEFORE YOU DIG ��I 111 C4.1 4 W1 smEEr uwr PHONE: (425) 263-5482 CALL'811' 1AR BY -' -- an NXWco•c axaw 11" 13 20 p � -_ BUILDING FIREPROTErTION NYLAND APARTMENTS BLDGI - 2016 NFPA 13R 8509 - 244TH STREET SW EDMONDS, WA 98026 HYDRAULIC CALCULATIONS MATERIAL SPECIFICATIONS 14401 Issaquah -Hobart Rd SE (425) 271-5598 State Contractor's License STE 304, Issaquah, WA 98027 Fax: (425) 496-8363 # MOOREFP116NP RECO %E J MAR 13 2020 BUILDING sbarnes@cornerstonearch.com From: Cody Gray <CodyG@ovwater.com> Sent: Friday, December 6, 2019 9:06 AM To: Steve Barnes Cc: Peter Paulsen; Justin Barnes; Marty Henninger Subject: RE: 8509 & 8513 244th St SW Hello Mr. Barnes, Please see the requested info for site, if you have any further questions please let me know. Have a great weekend!! Node F-2455 is generally the closest, but conditions have or will change with the ex. 6" being replaced with 8" and the main extended a little further into the Nyland site. The FF should be run under the changed or future system conditions. We therefore updated the model to show the upsized 8" and extended the pipe to the FH onsite that is represented by node F-2456 (see screenshot below). Velocity: 10.9±-fps FF with Max. 10-fps: 1,560±-gpm with 26±-psi Residual Thank you, Cody -Lee A. Gray Operations Manager P-24M F-2 U Results for F-2456 under generally similar conditions as stated for 2016 Plan (MDD, Tank in middle of operating range, no pumps, etc.): Static: 63±-psi Fire Flow: 1,700±-gpm with 20±-psi Residual 1 Olympic View Water & Sewer District 8128 228th St. SW Edmonds, WA 98026-8449 Office: (425) 774-7769 k Y7_4 M3'I131f h�RUfltNl From: Steve Barnes <sbarnes@cornerstonearch.com> Sent: Friday, November 22, 2019 8:38 AM To: Cody Gray <CodyG@ovwater.com> Cc: Peter Paulsen <peterp@paceengrs.com>; Justin Barnes <greenwalkdevelopment@hotmail.com> Subject: 8509 & 8513 244th St SW Cody, thanks for all the information in the pre -con meeting. Can you send me the water availability for the fire sprinkler design? Thanks Steve Barnes Cornerstone Architectural Group 6161 NE 175th Street, ste 101 Kenmore, WA 98028 (206) 682-5000 NYLAN D APARTMENTS 1. OH1 - ELECT SERVICE -FP2 1-HEAD CALCULATION 1111 Hydraulic Overview I Job Number: Nyland Apartments Renart Desnrinfinn- (7rdlnAry rrnun 1 Job Job Numb, Nyland Apartments Despn Enpin.r Matthew Steele Job N.— Nyland Apartments Phan. 425-891-3863 PAX 425496-8363 Add,-1 8509 - 244th St. SW SWW COftO NL—m Numb, MOOREFP116NP Md...2 Edmonds, WA 98026 AHJ City of Seattle Fire Marshal Mdr..3 Job S-Bulldinp Nyland Apartments System D..IIy Mee 1 Appkc.Wn 0.15gpm/ft2 900ft2 (Actual 73ft2) Mast Dem.ndinp Sprinkler Data 4.9 K-Factor 19.50 at 15.837 H.- Str.ems 0.00 Cov.re9. Per Sprinkler N.—V Spdnkk, C.I.W.d numb, DI Sp.WNr. C W- 130ft2 1 0 SYetem Reiser. OertbM 38.449 System Flow Oeme,M 19.50 TWO N. M 19.50 @ 38.449 Pressure Resuk +24.540(39.0%) Supplies Check Point Gauges Node Name Flow(eom) Hose Flow(aom) Static(psi) Residual(psi) Identifier Pressure(psi) K-Faclor(K) Flow(eom) 1 Water Supply 1700.00 63.000 20.000 1 Water Supply 1700.00 63.000 20.000 ............. �...............� • ■ tEApaM YFON OTATU ■ eCIl71=aATR 07 ■ Rif /Q,OMOTWO �� ■ • ORJiiuuiizt arrow Tracy V. Moore • 8851-0791-C43 Level • Moore Fire ProtoWon Ill I'llew • �rw so ENG 20200117_Nylan_DWG_work.cad Supply at Node 1 (1700.00, 0.00, 63.000, 20.000) 100 30 80 �t Prffitae 63.000 t =Static I ! , I 00 j I CL 50 40 -.F4D.00 U.449. ti 30 t t 20 1700.00 20.000 10 0 2100 2800 3500 05�111-FSO 2450 3150 Water flour, gpm & 0 M.E.P.CAD, Inc. fil AutoSPRINK 2019 v15.1.15.0 1/30/2020 10:39:46AM Page 1 Job Number: Nyland Apartments Renort Description: Ordinary Group I 50D � i tag T$I P i q .s_w x #.i poi -� (A'? i itl^ 1 ; i'^�3.`-C�..z� - - .-. ..'bP,P'.'1RM' ..-"fir f4'T c't'k . Job Number Nyland Apartments Design Engineer Matthew Steele Job Name: Nyland Apartments state oWieatieNLiwnu Number MOOREFP116NP Address t 8509 - 244th'St. SW AHJ City of Seattle Fire Marshal Address 2 Edmonds, WA 98026 Job SNelSugdMg Nyland Apartments Md..3 Drawing Name ENG_20200117_Nylan DWG_work.cad Systems �'Y��-�� �` �;;� '�i��,°y 3� Remo eA�ea(s)�ie",��'.`` `�� .�'�r"°."•,��'r ,.�: Most D.m —g sprinkler Data 4.9 K-Factor 19.50 at 15.837 Oxupancy Ordinary Group I Job suRu Hose Ano— Al Source 0.00 Demby 0.15gpm/ft2 Area of Appl"Von 900ft2 (Actual 73ft2) Addlllonsl Hose suppkes Node Flow m Number Of Sprinkler, Cukuluted H—F or Nozzles Celculatad 1 0 Cover.go Per Sprinkler 130ft2 MI.Peak R... b: Pressure For —1. Pree(s)11re nl To Most Ramate Ma torsi Hose Streams 0.00 System Flow Demand 19.50 Total Miler Required (Including Hose An—noa) 19.50 Me.lmum Pressure Unbelence In Loops 0.000 Maximum Velocity Above Ground 6.57 between nodes 280 and 420 Medm.m Vslooity Under Ground 1.99 between nodes 1 and 102 wtome "peony o1 Wet Pipes 510.82gal wWrrle opatlry of OrY Pipes Suppliesnx"`... > ,.e'aNJn�,.-:`-z.,' ,w x�.r ,a Node Name Hose Flow (gpm) Static (psi) Residual Flow (psi) eo (gpm) Available Total Demand (psi) (gpm) Required (psi) Safety Margin (psi) 1 Water Supply 63.000 20.000 1700.00 62.989 0.00 0.000 62.989 1 Water Supply 63.000 20.000 1700.00 62.989 19.50 38.449 24.540 �. 1, < �, � � « a 'i�':1' .W,e ',! s�—wa. ...�r. ^''s, 19 o °?5w ,- H',: - r.t,l-. ,. con do, N.— 21 contest N. m. Tracy V. Moore conl.et 1111. President Nam. of Contr.stor: Moore Fire Protection Phone 425-271-5598 Eareren, Andre»I 14401 Issaquah -Hobart Rd. SE STE 301 FAX Address 2 Issaquah, WA98027 E.mae tracyvmoore@moorefire.com Address ] YJebSga www.moorefire.com & 0 M.E.P.CAD, Inc. W AutoSPRINK 2019 v15.1.15.0 1/30/2020 10:39:50AM Page 2 Job Number: Nyland Apartments D—n rlecrr{ns{..n ll..l;..n... n... — I Supply at Node 1 100 90 80 70 1 Static Messuire 63.000 60 .p n o_ 50 3 O O a 40 -0.00 @ 38.449 30 —_System demand curve 20 1700.00 20.000 10 0 0SW 700 1050 1400 1750 2100 2450 2800 3150 3500 Water flow. GPM Hytlraullc Grapf, Supply at Node 1 titetic: Praasure 63.000 R-dua1: Pressure 20.000 @ 1700.00 AvaiaEle Pressure It Time of Test 20.000 @ 1700.00 System Dement 38.460 @ 0.00 SO— Demaid (t—W Hose Nbxarar at Sowcel 38.460 @ 0.00 & © M.E.P.CAD, Inc. kIn AutoSPRINK 2019 v15.1.15.0 1/30/2020 10:39:52AM Page 3 Job Number: Nyland Apartments Water Supply at Node 1 100 so 80 ,0 ---- Pressure 63.000 60 A n o 50 A O Q 40 =19.50 38.449 30 _System demand curve 20 i?OO.QD 20.000 10 0 0350 '00 1400 2100 2800 3500 1050 1750 2450 3150 Water fbw. gpm Hyareulk G,,ph Water Supply at Node 1 stetk: P—, 63.000 R—ual: Pressure 20.000 @ 1700.00 A,e P,bla Pressure et Tme of Test 62.989 @ 19.50 sr:,ere �a�a 38.449 @ 19.50 snmm ooreod p awky more ak..eM.e m so,<a� 38.449 @ 19.50 /& 0 M.E.P.CAD, Inc. jfl AutoSPRINK 2019 v15.1.15.0 1/30/2020 10:39:52AM Page 4 SummaryOfOutFlowing;D@VICeS� p; ,j Job Number: Nyland Apartments I Report Description: Ordinary Group I Actual Flow Minimum Flow K-Factor Pressure Device m m K(psi) b Sprinkler 420 19.50 19.50 4.9 15.837 r-> Most Demanding Sprinkler Data & 0 M.E.P.CAD, Inc. jjjAutoSPRINK2019 05.1.15.0 1/30/2020 10:39:53AM Page 5 Job Number: Nyland Apartments Reoort Description: Ordinary GrouD I Node Elevation Foot Fittings Pressure(psi) Dischar e m 1 -3'-0 2S 38.449 19.50 1 -3'-0 2S 38.449 19.50 420 8'-10'h S r-15.837 15.837 19.50 102 V-2% BV 6-11Y2 25.319 103 3'-0'/2 24.490 108 9'-4 b 1'-0 18.698 280 9'-4 T 5'-0 17.234 k, © M.E.P.CAD, Inc. M AutoSPRINK 2019 v15.1.15.0 1/30/2020 10:39:55AM Page 6 (sit w. .}� ...1'F''k`�Yi P' ydraWi ioGlysiso ;; a _ Job Number: Nyland Apartments Report Description: Ordinary Group I Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Upstream Pt Pn Fittings Eq. Length Total Length Summary w•••••Route 1..... DR _ 1.1010 19.50 6.57 150 0.064928 12'-5 Pf 1.587 420 8'-101A 1950 4.9 280 V-4 15.837 17.234 Sprinkler, E(V-0), 2Tr(1'-0), T(5'-0) 12'-0 24'-5 Pe -0.190 Pv FR 1.5980 19.50 3.12 150 0.010581 100'-4 Pf 1.463 280 9'-4 108 9'-4 17.234 18.698 20Tr(1'-0), cplg(1'-0), 2T(8'-O), b 38'-0 138'-4 Pe -0.000 Pv FIR 2.0030 19.50 1.99 150 0.003522 V-31/s Pf 3.071 108 9'-4 103 3'-DYz 18.698 24.490 E(9'-0), f(-0.000), Tr(V-0), 2Tr(2' -0), f(-3.000) 14'-0 20'-3'/2 Pe 2.721 Pv FR 1.9590 19.50 2.08 150 0.003924 1'-10 Pf 0.035 103 3'-0'/z 102 1'-21% 24.490 25.319 BV(6'-111h) 6-111/2 8'-9Y: Pe 0.795 Pv UG 2.0030 19.50 1.99 150 0.003522 155'-5 Pf 11.308 102 1'-21/: 1 -3'-0 25.319 38.449 Tr(2'-0), E(11'-0), 2E(9'-0), Tr(9'- 0), cplg(V-0), 2BFP(-5.322), 25 33'-0 188'-5 Pe 1.822 Pv Equivalent P ape engths of %alves;anJ tting ((C ffi,20 0,,n y) W I Actual Inside Diameter 4.87 = Factor { Schedule 40 Steel Pipe Inside Diameter ) G Value Mu`(tiplier I ' Value Of C 100 130 Multiplying Factor 0.713 1.16 140 150 1.33 1.61 1� © M.E.P.CAD, Inc. MAutoSPRINK 2019 051.150 1/30/2020 10:39:57AM Page 7 Job Number: Nyland Apartments Report Description: Ordinary Group I Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq. Length Summary Upstream Total Length m-Over Diameter Inch anch Line Elevation Foot ossMain Flow gpm ainropDischarge gpm namic Velocity fps ed Main Pressure psi ed Riser i Length Foot iscellaneous Friction Loss psi/Foot utrigger HWC Hazen -Williams Constant iser Nipple Pt Total pressure at a point in a pipe prigand Pipe Pn Normal pressure at a point in a pipe nderground Pf Pe Pressure loss due to friction between points Pressure due to elevation difference between indicated points Pv Velocity pressure at a point in a pipe ALV Alarm Valve AngV Angle Valve b Bushing BaIV Ball Valve BFP Backflow Preventer BV Butterfly Valve C Cross Flow Turn 90' cplg Coupling Cr Cross Run CV Check Valve DeIV Deluge Valve DPV Dry Pipe Valve E 90° Elbow EE 45° Elbow Eel ll%' Elbow Ee2 221/2* Elbow f Flow Device Id Flex Drop FDC Fire Department Connection fE 90° FireLock(TM) Elbow fEE 45' FireLock(TM) Elbow flg Flange FN Floating Node IT FireLock(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve SFx Seismic Flex Spr Sprinkler St Strainer T Tee Flow Turn 90' Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap r & 0 M.E.P.CAD, Inc. jjAutoSPRINK 2019 v15.1.15.0 1/30/2020 10:39:57AM Page 8 f, IL Diagram (Gurrent;Vie n Job Number: Nyland Apartments Report Description: Ordinary GroupI t y � ti & 0 M.E.P.CAD, Inc. JjAutoSPRINK 2019 05.1.15.0 1/30/2020 10:39:59AM Page 9 NYLAN D APARTMENTS 2. RES - UNIT 6 - FP3 3-HEAD CALCULATION F>_ Job Number: Nyland Apartments Keport Liescription: Kesiciential -2 Job Number Nyland Apartments Matthew Steele Job N... Nyland Apartments ft.— 425-891-3863 I F" 425-496-8363 Add-1 8509 - 244th St. SW Stare Gnr aYONtke,ne .—W, MOOREFP116NP Address] Edmonds, WA 98026 AN City of Seattle Fire Marshal Atld—,3 Job Soo/B.ildhiq Nyland Apartments of Appic 11o, 0.05gpM/ft2 68ft2 (Actual 301ft2) Most Do —ding SpflnMo, Dom Nd.a St-- 4.9 K-Factor 12.96 at 7.000 0.00 Go—O. P.' SOnklo, Number Of Sp6,Xhm C,IoolMod 2502 3 b7; — 1. —.d — Sv FDemand .999 Z� 24 T-1 Do-M 40.24 @ 46.999 P., .. R—ft +15.959 (26.30A) S*U'Ppl'e'S; 'Aw M: Ch—'P:Rt.GZU)A6W$'M M Node Name owmHose Flow(opm) StatieosiResidual(osi) aYN) Identifier Pressure(psi) K-Factor(K) Flow (5pn 1 Water Supply 1700.00 63.000 20.000 1 Water Supply 1700.00 63.000 20.000 ------------- M--- • • wA ;Z;;;; r;;; W—M&m 8— Tracy V. Moore - 8851-0791-C-G Level 3 Moore Fire Protecbm : MOOMAP'lleup LK k, 0 M.E.P.CAD, Inc. W AutoSPRINK 2019 wl 5.1.15.0 1/30/2020 10:41:18AM Page 1 Hy�iiulic Summa Job Number: Nyland Apartments Report Description: Residential A., x �., � - :�S%+ .;�' 7y t' '.'�-' � '�#�'.~w3. �''�. .R�",-Le.vk i�"ax? ":,4''�r 9M �, �':'�t �'i�: r,. F �.y •i6 ':�-e '°" *"4+. B" -��, 9 t� .�i�a ��'�;�id:•; . � '-,(:25!%... y {.4Y i ,f# .:dd�.�. Y..ui... Job Numbet Nyland Apartments Dealp Engi.er Matthew Steele Job N. me: Slale Nyland Apartments CeddiaboWLIce.. NumDar MOOREFP116NP 8509 - 244th St. SW City of Seattle Fire Marshal Add.., 2 Edmonds, WA98026 Job SU/Building Nyland Apartments Md..3 D—N Name ENG 20200117_Nylan_DWG_work.cad System ru a t �: � „Remote"`Q�ea(s� = ' . Most Demanding Sprinkler Data Occupenq 4.9 K-Factor 12.96 at 7.000 Residential Joe sdla Hoso Allowance At Source D—it, 0.00 0.05gpm/ft2 Area olApplkation 768ft2 (Actual 301112) Addil'wnel Hose Supplies Number Node Flow m A,A.P Of SprinkWm Celwdoted Number Ol Nekris C,k d 3 0 Cwwoge Per Sp,mkler 256ft2 ek ResuR: Pressure For Remo® Nee(s) Adp Tw Most Mmda Ana Right: 47,445 Toler H.. &rearm 0.00 System Flow Demand 40.24 Total Wator Requlnd (Including Hose Allowance) 40.24 Meslmum Pressure Unbelen. In Loops 0.000 Ma vimum.1.4 Above Gourd 13.56 between nodes 271 and 273 Meelmum Velocity Under Gn d 4.10 between nodes 1 and 102 V _.pedty e1ftd Rpes 510.82gal Volumo cepady of Dry Pipes *� l aF.m,. Sipplie's� ..�(a :f^z��, fir= `'t'T'•.. r.�, a..'8r mF : - .�s:i>:a Node Name Hose Flow m Static (psi) Residual Flow (psi) e° (gpm Available Total Demand (psi) @ (g m) Required (psi)(psi) Safety Margin 1 Water Supply 63.000 20.000 1700.00 62.958 0.00 0.000 62.958 1 Water Supply 63.000 20.000 1700.00 62.958 40.24 46.999 15.959 Coritractor.,�g� , �.:.�_".. Donlractor N.- 21 Contew Nar,e Tracy V. Moore Comact TM1la President Name of Conbador: Moore Fire Protection PMne 425-271-5598 EA.mlen Atltlnss 1 14401 Issaquah -Hobart Rd. SE STE 301 FAX Address 2 Issaquah, WA 98027 E-mak tracyvmoore@moorefire.com Adereee g _ — _ --. vao-ske www.moorefire.com & © M.E.P.CAD, Inc, MAutoSPRINK 2019 v15.L15.0 1/30/2020 10:41:21AM Page 2 Job Number: Nyland Apartments Supply at Node 1 100 so 80 70 —Static Pressure 03.000 so a 0 50 -0.00 0 @ 40.399 a 40 30 :System demand curve 20 1700.00 20.000 10 \.. 01 1 1 fill1-1 -LIlllIII-L 3M _ 00 1050 1400 1750 2100 2450 2800 3150 3500 Water flow. gpm Hyd— k Graph Supply at Node 1 static: Pressure 63.000 ResMual: Pressure 20.000 @ 1700.00 Nveilablo Proasure et Tirre of Test 20.000 @ 1700.00 System Mnard 47.041 @ 0.00 System GemerM (MrAWirg Hose Nkwence el Source) 47.041 @ 0.00 & © M.E.P.CAD, Inc. 11 AutoSPRINK 2019 v15.1.15.0 1/30/2020 10:41:23AM Page 3 8Jjj HydauticGraph r Job Number: Nyland Apartments Rennrt Ilascrin inn- ResidPnfinl Water Supply at Node 1 100 90 so 70 —Static Pressure 03.000 .p n o 50 3 —4024 0 46.999 IL 40 30 -System demand cmve 1700.00 20.000 10 0 Q 700 1400 2100 2800 3500 W 1050 1750 2450 3150 Water flow, gpm Ryd—ft Graph Water Supply at Node 1 stall.: Pressure 63.000 Residual: Pressure 20.000 @ 1700.00 ... - Pressure.1 Time of Test 62.958 @ 40.24 syelemoemand 46.999 @ 40.24 smlem oemaro (h.�q Rue ulw+arse at sowce) 46.999 @ 40.24 & © M.E.P.CAD, Inc. NJ AutoSPRINK 2019 v15.1.15.0 1/30/2020 10:41:23AM Page 4 Summalry``�OfOutflowingt�Devices ���,.� '�%x� p �4. � Job Number: Nyland Apartments Report Description: Residential Device Actual Flow m Minimum Flow m K•Factor K(psi) Pressure Sprinkler 463 14.02 12.80 4.9 8.189 Sprinkler 517 13.26 12.80 4.9 7.321 'W Sprinkler 529 12.96 12.80 4.9 7.000 Most Demanding Sprinkler Data 0 M.E.P.CAD, Inc. kilAutoSPRINK 2019 05.1.15.0 1/30/2020 10:41:25AM Pane 5 Job Number: Nyland Apartments Report Descriotion: Residential Node Elevation Foot Pressure(psi) Dischar e m 1 -3'-0 _fittings 2S 46.999 40.24 1 -3'-0 2S 46.999 40.24 463 20'-5 S r -8.189 8.189 14.02 517 21'-4'/z S r -7.321 7.321 13.26 529 21'-4'/z S -7.000 7.000 12.96 102 1'-2% BV 6'-11'/z 32.234 103 3'-0'/z 31.307 108 9'4 b 1'-0 25.313 271 9'4 T 5'-0 18.453 273 21'-9Yz T 5'-0 8.462 449 2V-9Yz T 5'-0 , Tr 1'-0 7.316 © M.E.P.CAD, Inc. #j AutoSPRINK 2019 v15.1.15.0 1/30/2020 10:41:26AM Page 6 HydraullcAnalysis Job Number: Nyland Apartments Report Description: Residential Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Upstream Elevation Discharge K-Factor Pt Pn Fittings Eq. Length Total Length Summary v•••••Route 1..... DR 1.1010 12.96 4.37 150 0,030510 10'-2 Pf 0.494 529 449 2V-4'/x 21'-9% 12.96 4.9 7.000 7.316 Sprinkler, E(5'-0), Tr(1'-0) 6-0 16'-2 Pe -0.178 Pv BL 1.1010 26,22 8.84 150 0.112308 5'-1'/2 Pf 1.136 449 273 2V-9'/2 2V-9'/z 13,26 7.316 8.452 Flow (q) from Route 2 T(5'-O) 5'-0 10'-1'/2 Pe Pv BL 1.1010 40.24 13.56 150 0.248065 12'-6 Pf 4.586 273 271 21'-9'/2 9'-4 14.02 8.452 18.453 Flow (q) from Route 3 Tr(1'-0), T(5'-0) 6'-0 18'-6 Pe 5.414 Pv BL 1.5980 40.24 6.44 150 0.040425 124'-8Y: Pf 6.860 271 108 9'4 9'-4 18.453 25.313 27Tr(V-0), cplg(1'-0), 2T(8'-0), b (1--0) 45'-0 169'-8'/2 Pe -0.000 Pv FR 2.0030 40.24 4.10 150 0.013455 V-3'/z Pf 3.273 108 103 9'-4 3'-01/2 25.313 31.307 E(9'-0), f(-0.000), Tr(1'-0), 2Tr(2' -0), f(-3.000) 14'-0 20'-3'/z Pe 2.721 Pv FR 1.9590 40.24 4.28 150 0.014992 V-10 Pf 0.132 103 102 3'-0% T-2'/a 31.307 32.234 BV(6'-11%) 6'-11% 8'-9Y: Pe 0.795 Pv UG 2.0030 40.24 4.10 150 0.013455 155'-5 Pf 12.943 102 1 1'-2'/: -3'-0 32.234 46.999 Tr(2'-0), E(11'-0), 2E(9'-0), Tr(1'- 0), cplg(1'-0), 2BFP(-5.204), 23 3T-0 188'-5 Pe 1.822 Pv 0.00 Hose Allowance At Source 1 40.24 ®••••• Route 2••••• DR 1.1010 13.26 4.47 150 0.031803 0'-5 Pf 0.172 517 449 21'4% 21'-9'% 13.26 4.9 7.321 7.316 Sprinkler, T(5'-O) 5'-0 5'-5 Pe -0.178 Pv o•••••Route 3••••• DR 1.1010 14.02 4.73 150 0.035274 8'-7% Pf 0.869 463 273 20'-5 21'-9'/2 14.02 4.9 8.189 8.452 Sprinkler, 2T(5'-0), Tr(V-0), E(5'-0) 16'-0 24'-7% Pe -0.605 Pv EgtjivalenfPdpe Leng hs*ot�/alves and F ttings C 20 only) r_ Actual Inside Diameter 4.87 ( Schedule 40 Steel Pipe Inside Diameter } =Factor CjValueN_M�tiPlier , ij Value Of C 100 130 MultiplyingFactor 0.713 1.16 140 150 1.33 1.51 �j O M.E.P.CAD, Inc. ®'AutoSPRINK 2019 05.1.15.0 1/30/2020 10:41:28AM Page 7 Hydraulic�Anafysis � }', Job Number: Nyland Apartments Report Description: Residential Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq. Length Summary Upstream Total Length AO Arm -Over Diameter Inch BL Branch Line Elevation Foot CM Cross Main Flow gpm DN Drain DR Drop Discharge gpm DY Dynamic Velocity fps FM Feed Main Pressure psi FR Feed Riser Length Foot MS Miscellaneous Friction Loss psi/Foot OR Outrigger HWC Hazen -Williams Constant RN Riser Nipple SP Sprig Pt Total pressure at a point in a pipe ST Stand Pipe Pin Normal pressure at a point in a pipe UG Underground Pf Pe Pressure loss due to friction between points Pressure due to elevation difference between indicated points Pv Velocity pressure at a point in a pipe ALV Alarm Valve AngV Angle Valve b Bushing BaIV Ball Valve BFP Backflow Preventer BV Butterfly Valve C Cross Flow Tum 90° cplg Coupling Cr Cross Run CV Check Valve DeIV Deluge Valve DPV Dry Pipe Valve E 90° Elbow EE 45' Elbow Eel 11%.° Elbow Ee2 22'/� Elbow f Flow Device I'd Flex Drop FDC Fire Department Connection fE 90° FireLock(TM) Elbow fEE 45' FireLock(TM) Elbow flg Flange FN Floating Node fT FireLock(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve SFx Seismic Flex Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WrF Wirsbo WMV Water Meter Valve Z Cap I & © M.E.P.CAD, Inc. 11AutoSPRINK 2019 vl5.1.15.0 1/30/2020 10:41:28AM Page 8 & 0 M.E.P.CAD, Inc. III AutoSPRINK 2019 v15.1.15.0 1/30/2020 10:41:31AM Page 9 NYLAND APARTMENTS 3. RES - BEDROOM 603 - FP3 1-HEAD CALCULATION •++• +• ,•.�. .:w,r riWf AM am a ar. Am- 4"t'allY �r■r , ►" +,rya i� ,a■w ,�. �► Awl ir. 4wwL -aft Fmmw Aw 4m,Aft. rwwr Job Number: Nyland Apartments Kepon: uescription: Kesiaentiai 70� '. �4 Job Number Dse,p Engineer Nyland Apartments Matthew Steele J0 Name: Ptrone FAX Nyland Apartments 425-891-3863 425-496-8363 Address I Stele C.dft.R dVU—se N—W 8509 - 244th St. SW MOOREFP116NP Address 2 AHJ Edmonds, WA 98026 City of Seattle Fire Marshal Address 3 JrebSdeffl.11ding Nyland Apartments Density 0.05gpM/ft2 400ft2 (Actual 128ft2) Most Demanding Sprinkle, DNose Stmerm - 4.9 K-Factor 20.00 at 16.660 0.00 Q,..g. Per Sprinkle, N,d,t., Of SprinkW, C.W.I.d NuM-OfS,,1-11C11c.1.tsd1 400ft" 0 46.065 20.00 T-1 Demand ftes,— R—ft 20.00 @ 46.065 +16.923 (26.9%) 8—UPp"1'ieR'**Z;& Vd',! 42" W�E M 'Mt' CR—M.P.&KIt Mau'OA'J-�' Node Name Flow ) Hose Flow(qpm) Static(psi) Residual(psi) Identifier Pressure(psi) K-Factor(K) Flow(qpm) 1 Water Supply 1700.00 63.000 20.000 1 Water Supply 1700.00 63.000 20.000 FAW-i-WA ID i E! wwMNfr W STATE O UNION Tracy V. Moore 8851-0791-C43 Level 3 Moore Fire Protection Moogwimp 111MENEMMM 1110NEEMMM 1110MEEMMM EMMM EMMMM MEMMM &-0905014001750 2100 2450 2B00 3150 3500 Water flow, gpm & C M.E.P.CAD, Inc. 11, AutoSPRINK 2019 v1 5.1.15,0 1/30/2020 10:41:58AM Page 1 Job Number: Nyland Apartments Report Description: Residential �=.p�,.�_."���;�� Job Number Nyland Apartments Design Engi ear Matthew Steele Job Name: Nyland Apartments SMie G YOMloelMe NurtLer MOOREFP116NP Add... 8509 - 244th St. SW AHJ City of Seattle Fire Marshal redressg Edmonds, WA98026 Job Sk IE1,11diag Nyland Apartments Md— 3 pawing Name ENG 20200117 Nylan_DWG_work.cad Most Demanding Sprinkler DIM 4.9 K-Factor 20.00 at 16.660 Ozupenoy Residential Job Sum. Hose AJbMMBAt Souivo 0,00 DonaNy O.05gpm/ft2 Area of APplketion 400ft2 (Actual 128ft2) Additional Hose 3uppks Node Flow m Numbe, Ol Spiinkbrs Cakvleted Number Of Noubs CelwMted 1 0 Coverage Per Sp,lnklo, 400ft2 Avb,Pook Rasugs: P,assuia F., I—k..M) Mjaoent To Most Remote Area Total Hose Snaene 0.00 System Fbw Demand 20.00 TOMI Water Required (Including Hose AIII—I e) 20.00 Main— Pressure Vnbalanm In loops 0.000 Maximum Wacky Above Ground 6.74 between nodes 283 and 509 NM.lmum Wloody under GmuM 2.04 between nodes 1 and 102 Volume ®peaty of Wet Pipes 510.82gal Volume capacity of Dry Pipes Supplies �.? - .>rs � i - +rp.� � 1 i ':a i , _ �' "fie E , r..,d Node Name Hose Flow (gpm) Static (psi) Residual Flow (psi) oe (gpm) Available Total Demand (psi) 9 (gpm) Required (psi) Safety Margin (psi) 1 Water Supply 63.000 20.000 1700.00 62.988 0.00 0.000 62.988 1 Water Supply 63.000 20.000 1700.00 62.988 20.00 46.065 16.923 �A,. Comnaer Number 21 C.M.0 NoConsole 9dI Tracy V. Moore President Noma of Conpaaor. Moore Fire Protection Phone Eatenslon 425-271-5598 Md... I 14401 Issaquah -Hobart Rd. SE STE 301 FAX Ads— 2 Issaquah, WA98027 E mei tracyvmoore@moorefire.com Md... 3 Mb-Sire www.moorefire.com & 0 M.E.P.CAD, Inc. ere AutoSPRINK 2019 v15.1.15.0 1/30/2020 10:42:01AM Page 2 Job Number: Nyland Apartments Ronnrt Descri..ticn% Roe GAentinl Supply at Node 1 100 90 80 70 —Stalk Pressure 63.000 so -EN n o 550 w o ,0110 48.0115 a 40 —System dernand curve 20 1700.00 20.000 10 0 03W 700 1050 1400 1750 2100 2450 2800 3150 3500 water flow gpm Hydr,—Gr, Supply at Node 1 Static: Preswre 63.000 ResW.I: Pressure 20.000 @ 1700.00 M.ila bte Pressure at n— o/ Tast 20.000 @ 1700.00 System cemantl ' 46.077 @ 0.00 So— oamma Ibtixmi„a Hoag aa,a„aa at swreat 46.077 @ 0.00 & 0 M.E.P.CAD, Inc. 11 AutoSPRINK 2019 05.1.15.0 1/30/2020 10:42:03AM Page 3 ���� Hydraulia,Graph-; Job Number: Nyland Apartments Renort Description Residential Water Supply at Node 1 100 s0 e0 70 —staiic Ptesure 63.000 60 e n 0 50 0 o —20.00 @ 46.065 a N Q-1 30 -5ystgm dQmsnri curve 20 1700.00 20A00 10 0 700 1400 2100 2800 3500 % W 1050 1750 2450 3150 Water flow. gprn Hyd— k Graph Water Supply at Node 1 stark: P—.. 63.000 Realdual: Prea — 20.000 @ 1700.00 Av,H ble Pressure et Time pf TW 62.988 @ 20.00 system Ixmem 46.065 @ 20.00 sntem IlmwM (hu,are Hasa aio.erce ei soa�t 46.065 @ 20.00 & © M.E.P.CAD, Inc. fA AutoSPRINK 2019 v15.1.15.0 1/30/2020 10:42:03AM Page 4 SummaryOf OutflowingDev�cesM� _ Job Number: Nyland Apartments & 0 M.E.P.CAD, Inc. NJ Auto SPRINK 2019 v15.1.15.0 1/30/2020 10:42:05AM Page 5 Job Number: Nyland Apartments Report Description: Residential Node Elevation Foot Pressure si Dischar e m 1 -3'-0 _fittings 2S 46.065 20.00 1 -3'-0 2S 46.065 20.00 509 20'-5% S r-16.660 16.660 20.00 102 V-2'/: BV 6'-11'/z 32.948 103 3'-0'/z 32.117 108 9'-4 b 1'-0 26.321 283 9'-4 T 5'-0 24.595 & 0 M.E.P.CAD, Inc. MAutoSPRINK 2019 v15.1.15.0 1/30/2020 10:42:06AM Page 6 Hydlraulic�Analysis ,;� , ��� �F Job Number: Nyland Apartments Report Description: Residential Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Elevation Discharge IK-Factor Pt Pn Fittings Eq. Length Summary Upstream Total Length go•••••Route 1 DR 1.1010 20.00 6.74 150 0.068041 19'-6 Pf 3.096 509 20'-5%2 20.00 4.9 16.660 Sprinkler, 26'-0 Pe 4.840 283 914 24,595 4E(5'-0), Tr(1'-0), T(5'-0) 45'-6 Pv FIR 1.5980 20.00 3.20 150 0.011088 114'-8 Pf 1.726 283 91-4 24.595 41'-0 Pe -0.000 108 914 26,321 23Tr(1'-0), cplg(1'-0), 2T(8'-0), b 155'-8 Pv (1--0) FR 2.0030 20.00 2.04 150 0.003691 6'-3'% Pf 3.075 108 91-4 26.321 14'-0 Pe 2.721 103 3'-0'/2 32.117 E(9'-0), f(-0.000), Tr(1'-0), 2Tr(2' 20'-3% Pv -0), f(-3.000) FIR 1.9590 20.00 2.13 150 0.004112 1'-10 Pf 0.036 103 3'-0'h 32.117 6'-11'/2 Pe 0.795 102 1'-2'h 32.948 BV(W-11,/2) 8'-9'/2 Pv UG 2.0030 20.00 2.04 150 0.003691 155'-5 Pf 11.295 102 V-21/2 32.948 33'-0 Pe 1.822 1 -3'-0 46.065 Tr(2'-0), E(11'-0), 2E(9'-0), Tr(1'- 188'-5 Pv 0), cp1g(V-0), 2BFP(-5.300), 2S Egquui"v_a�enjipe eengtTisof ve n ttings'C 120onPyj .�„ C�%a•lueMult"`lie Actual Inside Diameter 487 Value Of C 100 130 140 150 Schedule 40 Steel Pie Inside Diameter P = Factor ) MultiplyingFactor 0.713 1.16 1.33 1.51 ZZ [dj 0 M.E.P.CAD, Inc. !4flAutoSPRINK 2019 a15.1.15-0 1/30/2020 10:42:08AM Page 7 Pipe Type Diameter Flow Velocity HWC Friction Loss Downstream Elevation Discharge K-Factor Pt Pn Fittings AO Arm -Over Diameter Inch BL Branch Line Elevation Foot CM Cross Main Flow gpm DN Drain Discharge gpm DR Drop DY Dynamic Velocity fps FM Feed Main Pressure psi FIR Feed Riser Length Foot MS Miscellaneous Friction Loss psi/Foot OR Outrigger HWC Hazen -Williams Constant RN Riser Nipple Pt Total pressure at a point in a pipe SP Sprig ST Stand Pipe Pn Normal pressure at a point in a pipe UG Underground Pf Pe Pressure loss due to friction between points Pressure due to elevation difference between indicated points Pv Velocity pressure at a point in a pipe Job Number: Nyland Apartments Report Description: Residential Length Pressure Eq. Length Summary ALV Alarm Valve AngV Angle Valve b Bushing BaIV Ball Valve BFP Backflow Preventer BV Butterfly Valve C Cross Flow Tum 90' cplg Coupling Cr Cross Run CV Check Valve DeIV Deluge Valve DPV Dry Pipe Valve E 90° Elbow EE 45' Elbow Eel 11%* Elbow Ee2 22'/� Elbow f Flow Device fd Flex Drop FDC Fire Department Connection fE 90' FireLock(TM) Elbow fEE 45' FireLock(TM) Elbow fig Flange FN Floating Node IT FireLock(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve SFx Seismic Flex Spr Sprinkler St Strainer T Tee Flow Turn 90' Tr Tee Run U Union WrF Wirsbo WMV Water Meter Valve Z Cap & © M.E.P.CAD, Inc. 11 AutoSPRINK 2019 v15.1.15.0 1/30/2020 10:42:08AM Page 8 & 0 M.E.P.CAD, Inc. NjAutoSPRINK 2019 05.1.15.0 1/30/2020 10:42:10AM Page 9 NYLAN D APARTMENTS MATERIAL SPECIFICATIONS -.. — ,.. A&W mi" _ am-4m a a. ar ,�t.�.�...., ..AM Aft Oft a► 4 as aft ..* a afta0 as arf. -W&Aft� ... tqccr Worldwide I www.tyco-fire.com Contacts RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Pendent Wet Pipe and Dry Pipe Systems General Description The TYCO RAPID RESPONSE Series LFII Residential Pendent and Recessed Pendent Sprinklers (TY2234) are deco- rative, fast response, frangible bulb sprinklers designed for use in residen- tial occupancies such as homes, apart- ments, dormitories, and hotels. When aesthetics and optimized flow charac- teristics are the major consideration, the Series LFII Residential Sprinklers (TY2234) should be the first choice. The Series LFII Residential Sprinklers are intended for use in the following scenarios: • wet and dry pipe residential sprin- kler systems for one- and two-family dwellings and mobile homes per NFPA 13D • wet and dry pipe residential sprinkler systems for residential occupancies up to and including four stories in height per NFPA 13R • wet and dry pipe sprinkler systems for the residential portions of any occupancy per NFPA 13 The recessed version of the Series LFII Residential Sprinklers is intended for use in areas with finished ceilings. It employs a two-piece Style 20 Recessed Escutcheon. The Recessed Escutcheon provides 1/4 inch (6,4 mm) of recessed adjustment or up to 1/2 inch (12,7 mm) of total adjustment from the flush ceiling position. The adjustment provided by the Recessed IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING' that provides cautions with respect to handling and instal- lation of sprinkler systems and components. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Escutcheon reduces the accuracy to which the pipe drops to the sprinklers must be cut. The Series LFII Residential Sprinklers have been designed with heat sensi- tivity and water distribution charac- teristics proven to help in the control of residential fires and to improve the chance for occupants to escape or be evacuated. Dry Pipe System Application The Series LFII Residential Pendent and Recessed Pendent Sprinklers offers a laboratory approved option for designing dry pipe residential sprinkler systems, whereas, most residential sprinklers are laboratory approved for wet systems only. Through extensive testing, it has been determined that the number of design sprinklers (hydraulic design area) for the Series LFII Residential Pendent and Recessed Pendent Sprinklers (TY2234) need not be increased over the number of design sprinklers (hydraulic design area) as specified for wet pipe sprinkler systems, as is accustomed for density/ area sprinkler systems designed per NFPA 13. Consequently, the Series LFII Residential Sprinklers offer the features of non -water filled pipe in addition to not having to increase the number of design sprinklers (hydraulic design area) for systems designed to NFPA 13, 13D, or 13R. Non -water filled pipe will permit options for areas sensitive to freezing. NOTICE The Series LFII Residential Pendent and Recessed Pendent Sprinklers (TY2234) described herein must be installed and maintained in compliance with this document and the applicable stan- dards of the National Fire Protection Association, in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the perfor- mance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Number (SIN) TY2234 Page 1 of 6 APRIL 2013 TFP400 TFP400 Page 2of6 7/16" (11,1 mm) 1/2" ESCUTCHEON Components: NOMINAL NPT PLATE SEATING 1 - Frame 2 - Button MAKE -IN SURFACE 3 -Sealing Assembly 1 4 -Bulb 5 - Compression Screw 2 2-1/4" 6 - Deflector 3 A p (57,2 mm) 4 1-5/8" (41,3 mm) * Temperature 5 rating is indicated on 6 Deflector. CROSS SECTION PENDENT 7/16t1 /8" (11,1t3,2 mm) FACE OF SPRINKLER FITTING MOUNTING SURFACE CLOSURE 2-7/8" DIA. (73,0 mm) WRENCH J I STYLE 20 ESRECESSED CUTCHEON FLATS EON `�' / RECESSED PENDENT FIGURE f RAPID RESPONSE SERIES LFII RESIDENTIAL PENDENT AND RECESSED PENDENT SPRINKLERS (TY2234) 2-7/8" DIA. (73,0 mm) 1/2" (12,7 mm) 2-1/4" DIA. 1/4"(6,4 mm) (57,2 mm) MOUNTING PLATE A 1/8" (3,2 mm) TY2234 FIGURE 2 STYLE20 RECESSED ESCUTCHEON FOR USE WITH THE RAPID RESPONSE SERIES LFII RESIDENTIAL PENDENT SPRINKLER (TY2234) Technical Data Approvals UL Listed for use with wet pipe and dry pipe systems C-UL Listed for use only with wet pipe systems NSF Certified to NSF/ANSI 61 For details on these approvals, refer to the Design Criteria section. Maximum Working Pressure 175 psi (12,1 bar) Discharge Coefficient K=4.9 GPM/psi1t2 (70,6 LPM/bars/2) Temperature Rating 155°F (68°C) or 175°F (79°C) Finishes Natural Brass Pure or Signal White Chrome Plated Physical Characteristics Frame .................... Brass Button ...................Copper Sealing Assembly ........ Beryllium Nickel w/TEFLON Bulb (3 mm) ................ Glass Compression Screw ......... Bronze Deflector ................. Bronze Ejection Spring ......Stainless Steel / WRENCH RECESS (END "A" USED FOR TY2234) FIGURE 3 W-TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 4 W-TYPE 7 RECESSED SPRINKLER WRENCH Operation The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and flow water. Design Criteria The TYCO RAPID RESPONSE Series LFII Residential Pendent and Recessed Pendent Sprinklers (TY2234) are UL and C-UL Listed for installation in accordance with this section. Residential Sprinkler Design Guide When conditions exist that are outside the scope of the provided criteria, refer to the Residential Sprinkler Design Guide TFP490 for the manufacturer's recommendations that may be acceptable to the local authority having jurisdiction. System Types Per the UL Listing, wet pipe and dry pipe systems may be utilized. Per the C-UL Listing, only wet pipe systems may be utilized. Refer to Technical Data Sheet TFP485 for the use of residential sprinklers in residential dry pipe systems. Ceiling Types Smooth flat horizontal, or beamed, or sloped, in accordance with the 2013 Edition of NFPA 13D, 13R, or 13 as applicable. Hydraulic Design (NFPA 13D and 13R) For systems designed to NFPA 13D or NFPA 13R, the minimum required sprinkler flow rates are given in Tables A and B as a func- tion of temperature rating and the maximum allowable coverage areas. The sprinkler flow rate is the minimum required discharge from each of the total number of "design sprinklers" as specified in NFPA 13D or NFPA 13R. The number of "design sprinklers" specified in NFPA 13D and 13R for wet pipe systems is to be applied when designing dry pipe systems. Hydraulic Design (NFPA 13) For systems designed to NFPA 13, the number of design sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required discharge from each of the four sprinklers is to be the greater of the following: • The flow rates.given in Tables A or B as a function of temperature rating and the maximum allowable coverage area. • A minimum discharge of 0.1 gpm/ft2 over the "design area" comprised of the four most hydraulically demanding sprinklers for actual coverage areas protected by the four sprinklers. The number of "design sprinklers" specified in NFPA 13 for wet pipe systems is to be applied when designing dry pipe systems. Dry Pipe System Water Delivery When using the Series LFII Residential Sprinklers (TY2234) in dry pipe sprin- kler systems, the time for water delivery must not exceed 15 seconds for the most remote operating sprinkler. Obstruction to Water Distribution Sprinklers are to be located in accor- dance with the obstruction rules of NFPA 13D, 13R, and 13 as appli- cable for residential sprinklers as well as with the obstruction criteria described within the Technical Data Sheet TFP490. Operational Sensitivity Sprinklers are to be installed with a deflector -to -ceiling distance of 1-1/4 to 4 inches. Sprinkler Spacing The minimum spacing between sprin- klers is 8 feet (2,4 m). The maximum spacing between sprinklers cannot exceed the length of the coverage area (Table A or B) being hydraulically calculated (e.g., maximum 12 feet for a 12 ft. x 12 ft. coverage area, or 20 feet for a 20 ft. x 20 ft. coverage area). TFP400 Page 3 of 6 Installation The TYCO RAPID RESPONSE Series LFII Residential Pendent and Recessed Pendent Sprinklers (TY2234) must be installed in accor- dance with this section: General Instructions Do not install any bulb type sprin- kler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diam- eter of the air bubble is approximately 1/16 inch (1,6 mm). A leak -tight 1/2 inch NPT sprinkler joint should be obtained by applying a minimum -to -maximum torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprin- kler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in an Escutcheon Plate by under- or over - tightening the sprinkler. Re -adjust the position of the sprinkler fitting to suit. Series LFII Residential Pendent Sprinklers The Series LFII Residential Pendent Sprinklers must be installed in accor- dance with the following instructions. Step 1. Install pendent sprinklers in the pendent position with the deflector parallel to the ceiling. Step 2. With pipe thread sealant applied to the pipe threads, hand - tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W Type 6 Sprinkler Wrench (Figure 3). With reference to Figure 1, apply the W-Type 6 Sprinkler Wrench to the wrench flats. Series LFII Residential Recessed Pendent Sprinklers The Series LFII Residential Recessed Pendent Sprinklers must be installed in accordance with the following instructions. Step A. Install recessed pendent sprinklers in the pendent position with the deflector parallel to the ceiling. Step B. After installing the Style 20 Mounting Plate over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand - tighten the sprinkler into the sprinkler fitting. (Continued on Page 5) TFP400 Page 4 of 6 WET PIPE SYSTEM Minimum Flow and Residual Pressurelb,c) Max. overagg CArea Ordinary Temp. Rating Intermediate Temp. Rating 0 155°F (68°C) 175°F (79°C) Minimum Deflector to Installation Spacing Flow Pressure Flow Pressure Ft. x Ft. Ceiling Type Ft. (m x m) GPM PSI GPM PSI (m) (L/min) (bar) (L/min) (bar) 12 x 12 13 7.0 13 7.0 Smooth (3,7 x 3,7) (49,2) (0,48) (49,2) (0,48) Ceilings 1-1/4 to 14x14 (4,3 x 4,3) 13 (49,2) 7.0 (0,48) 13 (49,2) 7.0 (0,48) 4 inches Beamed Recessed using Style 20 16 x 16 13 7.0 13 7.0 Ceilings per Escutcheon or 8 (4,9 x 4,9) (49,2) (0,48) (49,2) (0,48) NFPA 13D or 13R non -recessed NPA18 pe13RF orr 13D (2,4) x 18 17 12.0 17 12.0 (5,5 x 5,5) (64,3) (0,83) (64,3) (0,83) 1-1/4 to 1-3/4 inches below bottom of 20 x 20 20 16.7 20 16.7 (6,1 x 6,11) (75,7) (1,15) (75,7) (1,15) beam. (a) For coverage area dimensions less than or between those indicated, use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. (b) Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. Refer to Hydraulic Design under the Design Criteria section. (c) For NFPA 13 residential applications, the greater of 0.1 gpm/ft2 over the design area of the flow in accordance with the criteria in this table must be used. TABLE A WET PIPE SYSTEM SERIES LFII RESIDENTIAL PENDENT AND RECESSED PENDENT SPRINKLERS (TY2234) NFPA 13D, 13R, AND 13 HYDRAULIC DESIGN CRITERIA DRY PIPE SYSTEM Maximum Minimum Flow and Residual Pressurelb,c) Coverage Area (a) Ordinary Temp. Rating Intermediate Temp. Rating Minimum 155°F (68°C) 175°F (79-C) Ft. x Ft. Deflector to Installation Spacing Flow Pressure Flow Pressure (m x m} Ceiling Type Ft. GPM PSI GPM PSI (m) (L/min) (bar) (L/min) (bar) 12 x 12 13 7.0 13 7.0 Smooth (3,7 x 3,7) (49,2) (0,48) (49,2) (0,48) 1 Ceilings 11/4to 14x14 (4,3 x 4,3) 14 (53,0) 8.2 (0,57) 14 (53,0) 8.2 (0,57) 4 inches Beamed Recessed using Style 20 16 x 16 15 9.4 15 9•4 Ceilings per Escutcheon or 8 (4,9 x 4,9) (56,8) (0,65) (56,8) (0,65) NFPA 13D or 13R non -recessed perD i R, orr 13 (2,4) 18 x 18 18 13.5 18 13.5 (5,5 x 5,5) (68,1) (0,93) (68,1) (0,93) 1-1/4 to 1-3/4 inches below bottom of 20 x 20 21 18.4 21 18.4 (6,1 x 6,1) (79,5) (1,27) (79,5) (1,27) beam. (a) For coverage area dimensions less than or between those indicated, use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. (b) Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. Refer to Hydraulic Design under the Design Criteria section. (c) For NFPA 13 residential applications, the greater of 0.1 gpm/ft2 over the design area of the flow in accordance with the criteria in this table must be used. TABLE B DRY PIPE SYSTEM SERIES LFII RESIDENTIAL PENDENT AND RECESSED PENDENT SPRINKLERS (TY2234) NFPA 13D, 13R, AND 13 HYDRAULIC DESIGN CRITERIA Step C. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 4). With reference to Figure 1, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Step D. After the ceiling has been installed or the finish coat has been applied, slide on the Style 20 Closure over the Series LFII Residential Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. Care and Maintenance The TYCO RAPID RESPONSE Series LFII Residential Pendent and Recessed Pendent Sprinklers (TY2234) must be maintained and serviced in accordance with this section: Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. The owner must assure that the sprinklers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; other- wise, non -operation in the event of a fire or inadvertent operation may result. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers - before, during, and after installation. Sprinklers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section.) The owner is responsible for the Inspection, testing, and mainte- nance of their fire protection system and devices in compliance with this document, as well as with the appli- cable standards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any authorities having jurisdiction. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems are recommended to be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assembly Specify: Series LFII (TY2234), K=4.9, Residential Pendent Sprinkler, (specify) temperature rating, (specify) finish, P/N (specify). 156T (66°C) Natural Brass .............. P/N 51-201-1-155 Pure White (RAL 9010)' ......P/N 51-201-3-155 Signal White (RAL 9003) .....P/N 51-201-4-155 Chrome Plated.............P/N 51-201-9-155 175-F(79°C) Natural Brass .............. P/N 51-201-1-175 Pure White (RAL 9010)" ...... P/N 51-201-3-175 Signal White (RAL 9003) .....P/N 51-201-4-175 Chrome Plated.............P/N 51-201-9-175 'Eastern Hemisphere sales only. Recessed Escutcheon Specify: Style 20 Recessed Escutcheon with (specify`) finish, P/N (specify*). 'Refer to Technical Data Sheet TFP770. Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387. Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001. TFP400 Page 5 of 6 • .•++�. .+r. .wpc- rrri 411111111116 A& AM 4M AM 4M 41111111W�4111111111111111 MOM Uw dit AM 40fti .err. TFP400 Page 6of6 GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 19446 1 Telephone +1-216-362-0700 Copyright © 2013 Tyco Fire Products, LP. All rights reserved. .i.�CO TEFLON is trademark of The DuPont Corporation. tqC00 Worldwide I www.tyco-fire.com Contacts Series DS-1 Dry -Type Sprinklers 5.6K Pendent, Upright, and Horizontal Sidewall Quick Response, Standard Coverage General Description TYCO Series DS-1 Dry -Type Sprinklers, 5.6K Pendent, Upright, and Horizontal Sidewall, Quick Response (3 mm bulb) and Standard Coverage are decora- tive glass bulb automatic sprinklers designed for commercial use. Dry -type sprinklers are typically used where: • pendent sprinklers are required on dry pipe systems that are exposed to freezing temperatures (e.g., sprinkler drops from unheated portions of buildings) • sprinklers and/or a portion of the connecting piping are exposed to freezing temperatures; for example, sprinkler drops from wet systems into freezers, sprinkler sprigs from wet systems into unheated attics, or horizontal piping exten- sions through a wall to protect an unheated areas such as loading docks, overhangs, and building exteriors • sprinklers are used on systems that are seasonally drained to avoid freezing (e.g., vacation areas) NOTICE The Series DS-1 Dry -Type Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association (NFPA), in addition to the standards of any authorities IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. Always refer to Technical Data Sheet TFP700 for the `INSTALLER WARNING' that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and devices in proper operating condi- tion. Contact the installing contrac- tor or product manufacturer with any questions. The Series DS-1 Dry -Type Sprinklers must only be installed in fittings that meet the requirements of the Design Criteria section. Sprinkler Identification Numbers (SINS) 3/4 in. NPT: TY3935 — Pendent TY3735 — Horizontal Sidewall 1 in. NPT: TY3235 — Pendent TY3135 — Upright TY3335 — Horizontal Sidewall Technical Data Approvals UL and C-UL Listed FM Approved NYC Approved under MEA 352-01-E Previous New York City Approval and MEA certification numbers apply to product as shown in this data sheet. In accordance with Section BC 3502 of the Construction Code, current NYC Approvals for use in the City of New York apply to all products that contain UL or FM Approvals and Listings; therefore, not all products currently Approved for use in the City of New York will carry an actual MEA Certifi- cation number. Refer to Tables A and B. Maximum Working Pressure 175 psi (12,1 bar) Inlet Thread Connections 3/4 in. NPT 1 in. NPT or ISO 7-R 1 Discharge Coefficient K=5.6 gpm/psil/2 (80,6 Ipm/barl/2) Temperature Ratings Refer to Tables A and B Finishes Sprinkler: Natural Brass, Chrome Plated, or Signal White Escutcheon: Signal White, Chrome Plated, or Brass Plated Physical Characteristics Inlet ............................. Copper Plug ............................ Copper Yoke. ...................... Stainless Steel Casing ............. Galvanized Carbon Steel Insert ........................... Bronze Bulb Seat ................... Stainless Steel Bulb...............................Glass Compression Screw .................Bronze Deflector ......................... Bronze Frame ............................Bronze Guide Tube ................. Stainless Steel Water Tube ................. Stainless Steel Spring ..................... Stainless Steel Plug Spring ................ Stainless Steel Sealing Assembly. Beryllium Nickel w/TEFLON Escutcheon ...................Carbon Steel For 3/4 inch NPT only Page 1 of 10 AUGUST 2018 TFPS10 TFP510 Page 2 of 10 PLUG WITH INLET SEALING ASSEMBLY YOKE PLUG INLET SPRING BAND WATER SPRING TUBE CASING GUIDE INSERT TUBE BULB SEAT FRAME 3 mm BULB VENT HOLE COMPRESSION DEFLECTOR SCREW FIGURE 1 SERIES DS-1, 3/4 INCH NPT, DRY -TYPE SPRINKLER ASSEMBLY PLUG WITH INLET SEALING ASSEMBLY YOKE SPRING — INLET BAND WATER TUBE CASING GUIDE INSERT TUBE BULB FRAME SEAT 3 mm BULB VENT HOLE COMPRESSION DEFLECTOR SCREW FIGURE 2 SERIES DS-1, 1 INCH NPT AND ISO 7-17 1 DRY -TYPE SPRINKLER ASSEMBLY Operation When the TYCO Series DS-1 Dry Type Sprinklers, 5.6K Pendent, Upright, and Horizontal Sidewall, Quick Response (3 mm bulb) and Standard Coverage are in service, water is prevented from entering the assembly by the Plug with Sealing Assembly in the Inlet of the Sprinkler. See Figures 1 and 2. The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, and the Bulb Seat is released. The compressed Spring is then able to expand and push the Water Tube as well as the Guide Tube outward. This action simultaneously pulls inward on the Yoke, withdrawing the Plug with Sealing Assembly from the Inlet and allowing the sprinkler to activate and flow water. Design Criteria The TYCO Series DS-1 Dry Type Sprin- klers, 5.6K Pendent, Upright, and Hor- izontal Sidewall, Quick Response (3 mm bulb) and Standard Cover- age are intended for use in fire sprin- kler systems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency; for example, UL Listing is based on NFPA 13 requirements. Sprinkler Fittings Install the 3/4 or 1 inch NPT Series DS-1 Dry -Type Sprinklers in the 3/4 or 1 inch NPT outlet or run of the follow- ing fittings: • malleable or ductile iron threaded tee fittings that meet the dimen- sional requirements of ANSI B16.3 (Class 150) • cast iron threaded tee fittings that meet the dimensional requirements of ANSI B16.4 (Class 125) Do not install the DS-1 Sprinklers into an elbow fittings. The Inlet of the sprinkler can contact the interior of the elbow, potentially damaging the Inlet seal. The unused outlet of the threaded tee is plugged as shown in Figure 13. You can also install the Series DS-1 Dry Type Sprinklers in the 3/4 or 1 inch NPT outlet of a GRINNELL Figure 730 Mechanical Tee. However, the use of the Figure 730 Tee for this arrangement is limited to wet pipe systems. TFP510 Page 3 of 10 3/4Inch NPT TY3935 Pendent TY3935 Pendent TY3735 Horizontal Sidewall with Top of Deflector -to -Ceiling with Recessed Escutcheon with Standard Escutcheon Distance of 4 to 12 inches (Figure 4) (Figure 3) (100 to 300 mm) with Deep Escutcheon with Standard Escutcheon (Figure 5) (Figure 8) without Escutcheon with Deep Escutcheon (Figure 6) (Figure 9) without Escutcheon (Figure 10) Temperature Bulb Finish Natural Chrome White Natural Chrome I White Natural Chrome White Rating Color Code Brass Plated Polyester Brass Plated Polyester Brass I Plated I Polyester 135°F (57°C) Orange 1,2 1,2 1*, 2* 155°F 68°C Red 175*F 79°C Yellow 200°F 93°C Green 286°F(141°C) Blue Notes: 1. Listed by Underwriters Laboratories, Inc. (maximum order length of 48 inches) 2. Listed by Underwriters Laboratories for use in Canada (maximum order length of 48 inches) ` Light and Ordinary Hazard occupancies only TABLE A 314 INCH NPT SERIES DS-1 QUICK RESPONSE, STANDARD COVERAGE DRY -TYPE SPRINKLERS LABORATORY LISTINGS AND APPROVALS 1 Inch NPT (and ISO 7-R 1) TY3235.Pendent TY3235 Pendent TY3335 Horizontal Sidewall with Top of Deflector -to -Ceiling with Recessed Escutcheon with Standard Escutcheon Distance of 4 to 12 inches (Figure 4) (Figure 3) (100 to 300 mm) with Deep Escutcheon with Standard Escutcheon (Figure 5) (Figure 8) without Escutcheon with Deep Escutcheon (Figure 6) (Figure 9) TY3135 Upright without Escutcheon without Escutcheons (Figure 10) (Figure 7) Temperature Bulb Finish Natural Chrome White Natural Chrome White Natural Chrome White Rating Color Code Brass Plated Polyester Brass Plated Polyester Brass I Plated Polyester 135°F 57°C Orange 1, 2, 3, 4 1, 2, 4 1, 2, 3, 4 1, 2, 4 1*, 2*, 3**, 4 1*, 2*, 4 155°F 68°C Red 175°F 79°C Yellow 200°F 93°C Green 286°F 141°C Blue 1,2,4 Notes: 1. Listed by Underwriters Laboratories, Inc. (maximum order (length of 48 inches) 2. Listed by Underwriters Laboratories for use in Canada (maximum order length of 48 inches) 3. Approved by Factory Mutual Research Corporation (maximum order length of 48 inches) 4. Approved by the City of New York under MEA 352-01-E 5. The Upright Sprinkler without an Escutcheon (TY3135) is available in 1 inch NPT only ' Light and Ordinary Hazard occupancies only Light Hazard occupancies only TABLE B 1 INCH NPT (AND ISO 7-17 1) SERIES DS-1 QUICK RESPONSE, STANDARD COVERAGE DRY -TYPE SPRINKLERS LABORATORY LISTINGS AND APPROVALS TFP510 Page 4 of 10 SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FACE OF SPRINKLER FITTING - L_ _J ORDER LENGTHS: 2-3/4" to 48" 1-3/4" DIA. (69,9 to 1219,2 mm) (44,5 mm) INCREMENTS FACE OF CEILING 2-3/16" t 1/8" 3" DIA. (55,6 t 3,2 mm) (76,2 mm) FIGURE 3 PENDENT TY3235 AND TY3935 WITH STANDARD ESCUTCHEON SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FACE OF SPRINKLER FITTING 1 L f _J ORDER LENGTHS: 3-3/4" to 48" (95,3 to 1219,2 mm) IN 1/4" (6,4 mm) 2-1/4" DIA. INCREMENTS (57,2 mm) FACE OF CEILING 1-3/8" t 1/8" 2-7/8" DIA. (34,9 t 3,2 mm) (73,0 mm) FIGURE 4 PENDENT TY3235 AND TY3935 WITH RECESSED ESCUTCHEON SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FACE OF SPRINKLER FITTING L_ _J ORDER LENGTHS: 5" to 48" (127,0 to 1219,2 mm) IN 1/4" (6,4 mm) INCREMENTS MINIMUM 1-3/4" (44,5 mm) DEFLECTOR TO CEILING FIGURE 6 PENDENT TY3235 AND TY3935 WITHOUT ESCUTCHEON SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FACE OF SPRINKLER FITTING L ORDER LENGTHS: 3 1/2" DIA. 1/2" to 46" (88,9 mm) (12,7 to 1168,4 mm) A. " DI IN 1/4" (6,4 mm) 2-1/2-1/2 D; INCREMENTS - FACE OF CEILING 4-1/4" t 1/8" (108,0 t 3,2 mm) FIGURE 5 PENDENT TY3235 AND TY3935 WITH DEEP ESCUTCHEON TOP OF DEFLECTOR ORDER LENGTHS: 5" to 48' (127,0 to 1219,2 mm) IN 1/4" (6,4 mm) INCREMENTS FACE OF SPRINKLER FITTING SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FIGURE 7 UPRIGHT TY3135 WITHOUT ESCUTCHEON 1 INCH NPT ONLY ORDER LENGTHS: 2-3/4" to 48" (69,9 to 1219,2 mm) IN 1/4" (6,4 mm) INCREMENTS 2-3/8" t 1 /8" (60,3 t 3,2 mm) FACE OF FACE OF SPRINKLER MOUNTING FITTING SURFACE 3" DIA. (76,2 mm) -� 3.5° SPRINKLER FITTING (REFER TO DESIGN (44,5 mm) CENTERLINE 5/16" CRITERIA SECTION) OF WATERWAY (7,9 mm) FIGURE 8 TY3335 AND TY3735 HORIZONAL SIDEWALL WITH STANDARD ESCUTCHEON ORDER LENGTHS: 1/2" to 45-3/4" (12,7 to 1162,1 mm) IN 1/4" (6,4 mm} INCREMENTS 4-1/4" t 1/8" 2-1/2" DIA. FACE OF (108,0 t 3,2 mm) FACE OF (63,5 mm) MOUNTING SPRINKLER SURFACE FITTING 3-1/2" DIA. (88,9 mm) -� 3.5° SPRINKLER FITTING (REFER TO DESIGN CENTERLINE 5/16" CRITERIA SECTION) OF WATERWAY (7,9 mm) FIGURE 9 TY3335 AND TY3735 HORIZONAL SIDEWALL WITH DEEP ESCUTCHEON ORDER LENGTHS: 5-1/2" to 48" (139,7 to 1219,2 mm) IN 1/4" (6,4 mm) INCREMENTS FACE OF SPRINKLER FITTING SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) MINIMUM 2-1/4" (57,2 mm) DEFLECTOR TO MOUNTING SURFACE 3.5° 5/16 (7,9 mm) CENTERLINE OF WATERWAY FIGURE 10 TY3335 AND TY3735 HORIZONAL SIDEWALL WITHOUT ESCUTCHEON TFP510 Page 5 of 10 The configuration shown in Figure 12 is only applicable for wet pipe systems where the sprinkler fitting and water - filled pipe above the sprinkler fitting are not subject to freezing and where the length of the Dry -Type Sprinkler has the minimum exposure length depicted in Figure 11. Refer to the Exposure Length section. For wet pipe system installations of the 1 inch NPT Series DS-1 Dry -Type Sprinklers connected to CPVC piping, use only the following TYCO CPVC fittings: • 1" x 1" NPT Female Adapter (P/N 80145) • 1" x 1" x 1" NPT Sprinkler Head Adapter Tee (P/N 80249) For wet pipe system installations of the the 3/4 inch NPT Series DS-1 Sprin- klers connected to CPVC piping, use in the 3/4" x 3/4" NPT Female Adapter (P/N 80142). For dry pipe system installations, use only the side outlet of maximum 2-1/2- inch reducing tee when locating the Series DS-1 Sprinklers directly below the branch line. Otherwise, use the configuration shown in Figure 13 to assure complete water drainage from above the Series DS-1 Dry -Type Sprin- klers and the branch line. Failure to do so may result in pipe freezing and water damage. ESM Do not install the Series DS-1 Dry -Type Sprinkler into any other type fitting without first consulting the Technical Services Department. Failure to use the appropriate fitting may result in one of the following: • failure of the sprinkler to operate properly due to formation of ice over the inlet Plug or binding of the Inlet Plug • insufficient engagement of the Inlet pipe threads with consequent leakage Drainage In accordance with the minimum requirements of the National Fire Pro- tection Association for dry pipe sprin- kler systems, branch, cross, and feed -main piping connected to Dry Sprinklers and subject to freezing tem- peratures must be pitched for proper drainage. Exposure Length When using Dry Sprinklers in wet pipe sprinkler systems to protect areas subject to freezing temperatures, use TFP510 Page 6 of 10 FACE OF SPRINKLER FITTING EXPOSURE Imm LENGTH (SEE DESIGN DSB-2 CRITERIA INTENDED SECTION) FOR FREEZER STRUCTURES - ll�--j FIGURE 11 EXPOSURE LENGTH STRAP TIES (ENDS ON OPPOSING SIDES OF BOOT) ISB-2 BOOT ADHESIVE 1-3/4" DIA. (44,5 mm) 'LEARANCE HOLE NSULATED FREEZER ITRUCTURE DS-1 HOWN WITH STANDARD ESCUTCHEON FIGURE 14 MODEL DSB-2 SPRINKLER BOOT WITH PENDENT SERIES DS-1 DRY SPRINKLER TO WET SIDE SYSTEM OUTLET PLUGGED DSB-2 SPRINKLER INTENDED FITTING FOR FREEZER (SEE DESIGN STRUCTURES CRITERIA SECTION) 6Lll-- -.X-- li FIGURE 12 SPRINKLER FITTING HEATED AREA 1-3/4" DIA. (44,5 mm) CLEARANCE INSULATED HOLE FREEZER ADHESIVE STRUCTURE DSB-2 BOOT STRAP TIES DS-1 (ENDS ON SHOWN WITH OPPOSING STANDARD SIDES OF ESCUTCHEON BOOT) FIGURE 15 MODEL DSB-2 SPRINKLER BOOT WITH SIDEWALL SERIES DS-1 DRY SPRINKLER RUN • OUTLET PLUGGED SPRINKLER TO DRY FITTING SYSTEM (SEE DESIGN CRITERIA SECTION) DSB-2 INTENDED FOR FREEZER STRUCTURES FIGURE 13 SPRINKLER FITTING UNHEATED AREA WRENCH RECESS WRENCH FLAT v 20 40 PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 16 W-TYPE 7 SPRINKLER WRENCH Temperatures for Heated Area' 40°F I 50°F 60°F Ambient Temperature Exposedto (4°C) (10°C) (16°C) Discharge End of Sprinkler Minimum Exposed Barrel Length2, Inches (mm) 40°F 0 0 0 (4°C) 30'F 0 0 0 (-1 °C) 20°F 4 (-7°C) (100) 0 0 10°F 8 1 (-12°C) (200) (25) 0 0°F 12 3 0 (-18°C) (305) (75) -10°F 14 4 1 (-23°C) (355) (100) (25) -20°F 14 6 3 (-29°C) (355) (150) (75) -30°F 16 8 4 (-34°C) (405) (200) (100) -40°F 18 8 4 (-40°C) (455) (200) (100) -50°F 20 10 6 (-46°C) (510) (255) (150) -60°F 20 10 6 (-51°C) (510) (255) (150) Notes: 1. For protected area temperatures that occur between values listed above, use the next cooler temperature. 2. These lengths are inclusive of wind velocities up to 30 mph (18,6 kph). TABLE C EXPOSED SPRINKLER BARRELS IN WET PIPE SYSTEMS MINIMUM RECOMMENDED LENGTHS Table C to determine a sprinkler's appropriate exposed barrel length to prevent water from freezing in the con- necting pipes due to conduction. The exposed barrel length measurement must be taken from the face of the sprinkler fitting to the surface of the structure or insulation that is exposed to the heated area. Refer to Figure 11 for an example. Clearance Space In accordance with NFPA 13, when connecting an area subject to freez- ing and an area containing a wet pipe sprinkler system, the clearance space around the sprinkler barrel of Dry -Type Sprinklers must be sealed. Due to temperature differences between two areas, the potential for the formation of condensation in the sprinkler and sub- sequent ice build-up is increased. If this condensation is not controlled, ice build-up can occur that might damage the dry -type sprinkler and/or prevent proper operation in a fire situation. Use of the Model DSB-2 Dry Sprin- kler Boot, described in Technical Data Sheet TFP591 and shown in Figures 14 and 15, can provide the recommended seal. Installation The TYCO Series DS-1 Dry Type Sprin- klers, 5.6K Pendent, Upright, and Hori- zontal Sidewall, Quick Response (3 mm bulb) and Standard Coverage must be installed in accordance with this section. General Instructions The Series DS-1 Dry -Type Sprinklers must only be installed in fittings that TFP51O Page 7 of 10 meet the requirements of the Design Criteria section. Refer to the Design Criteria section for other important requirements regarding piping design and sealing of the clearance space around the Sprinkler Casing. Do not install any bulb -type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 1350F (57°C) rating to 1/8 inch (3,2 mm) for the 286OF (141°C) rating. • A leak -tight 3/4 inch NPT sprinkler joint should be obtained by applying a minimum -to -maximum torque of 10 to 20 ft.-Ibs. (13,4 to 26,8 Nm). • A leak -tight 1 inch NPT sprinkler joint should be obtained by applying a minimum -to -maximum torque of 20 to 30 ft.-Ibs. (26,8 to 40,2 Nm). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in an Escutch- eon Plate by under or over -tightening the sprinkler. Re -adjust the position of the sprinkler fitting to suit. Step 1. Install pendent sprinklers only in the pendent position, and install upright sprinklers only in the upright position. The deflector of a pendent or upright sprinkler must be parallel to the ceiling. Install horizontal sidewall sprinklers in the horizontal position with their cen- terline of waterway perpendicular to the back wall and parallel to the ceiling. Ensure the word "TOP" on the Deflector faces the ceiling. Step 2. With a non -hardening pipe - thread sealant such as TEFLON tape applied to the Inlet threads, hand - tighten the sprinkler into the sprinkler fitting. Step 3. Wrench -tighten the sprinkler using either: • a pipe wrench on the Inlet Band or the Casing (Ref. Figures 1 and 2) • the W-Type 7 Sprinkler Wrench on the Wrench Flat (Ref. Figure 16) Apply the Wrench Recess of the W-Type 7 Sprinkler Wrench to the Wrench Flat. TFP510 Page 8 of 10 Note: If sprinkler removal becomes necessary, remove the sprinkler using the same wrenching method noted above. Sprinkler removal is easier when a non -hardening sealant was used and torque guidelines were followed. After removal, inspect the sprinkler for damage. Step 4. After installing the ceiling or wall and applying a ceiling finish, slide on the outer piece of the escutcheon until it comes in contact with the ceiling or wall. Do not lift the ceiling panel out of its normal position. When using the Deep Escutcheon, hold the outer piece in contact with the mounting surface (ceiling or wall). Then rotate the inner piece approximately 1/4 turn with respect to the outer piece, to hold the Deep Escutcheon firmly together. Care and Maintenance The TYCO Series DS-1 Dry -Type Sprin- klers, 5.6K Pendent, Upright, and Hori- zontal Sidewall, Quick Response (3 mm bulb) and Standard Coverage must be maintained and serviced in accordance with this section. Before closing afire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay the time to sprinkler operation in a fire situation. A Vent Hole is provided in the Bulb Seat (Ref. Figures 1 and 2) to indicate if the Dry -Type Sprinkler is remaining dry. Evidence of leakage from the Vent Hole indicates potential leakage past the Inlet seal and the need to remove the sprinkler to determine the cause of leakage (e.g., an improper installation or an ice plug). Close the fire protec- tion system control valve and drain the system before removing the sprinkler. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprin- kler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installa- tion Section.) The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Asso- ciation (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. Contact the install- ing contractor or product manufacturer with any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Number (P/N). DS-1 Dry -Type Sprinklers When ordering TYCO Series DS-1 Dry -Type Sprinklers, 5.6K Pendent, Upright, and Horizontal Sidewall, Quick Response (3 mm bulb) and Stan- dard Coverage, specify the following information: • SIN: Pendent - TY3935 or TY3235 Sidewall - TY3735 or TY3335 Upright - TY3135 • 5.6 K-factor • Deflector Style: Upright, Pendent, or Horizontal Sidewall • Quick Response, Standard Cover- age, Dry -Type Sprinkler • Order Length: Dry -Type Sprinklers are furnished based upon Order Length as measured per Figures 3 through 10. After taking the measurement, round it to the nearest 1/4 inch increment. • Inlet Connections: 3/4 in. NPT, 1 in. NPT, or ISO 7-R 1 • Temperature Rating • Sprinkler Finish • Escutcheon Style and Finish, as applicable • Part Number (P/N) from Table D The Upright Sprinkler without an Escutcheon (TY3135) is available in 1 in. NPT only. Part Numbers are for 3/4 in. and 1 in. NPT standard order sprin- klers. Orders for all other sprinkler assemblies must be accompanied by a complete description. Refer to the Price List for a complete listing of Part Numbers. Sprinkler Wrench Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 Sprinkler Boot Specify: Model DSB-2 Dry Sprinkler Boot, P/N 63-000-0-002 This Part Number includes one (1) Boot, two (2) Strap Ties, and 1/3 oz. of Adhesive (a sufficient quantity for installing one boot). P/N` 60 - XXX - X - XXX i SIN 01 Pendent with Standard TY3935 Escutcheon (3/4" NPT) (Figure 3) 02 Pendent with Deep TY3935 Escutcheon (3/4" NPT) (Figure 5) 03 Pendent with Recessed TY3935 Escutcheon (3/4" NPT) (Figure 4) 04 Pendent without TY3935 Escutcheon (3/4" NPT) (Figure 6) 05 Sidewall with Standard TY3735 Escutcheon (3/4" NPT) (Figure 8) 06 Sidewall with Deep TY3735 Escutcheon (3/4" NPT) (Figure 9) 07 Sidewall without TY3735 Escutcheon (3/4" NPT) (figure 10) 36 Pendent with Standard TY3235 Escutcheon (1 " N PT) (Figure 3) 33 Pendent with Deep TY3235 Escutcheon (1" NPT) (Figure 5) 37 Pendent with Recessed TY3235 Escutcheon (1" NPT) (Figure 4) 32 Pendent without TY3235 Escutcheon (1" NPT) (Figure 6) 34 Sidewall with Standard TY3335 Escutcheon (1" NPT) (Figure 8) 43 Sidewall with Deep TY3335 Escutcheon (1" NPT) (Figure 9) 44 Sidewall without TY3335 Escutcheon (1" NPT) (Figure 10) TFP510 Page 9 of 10 SPRINKLER ESCUTCHEON FINISH FINIISHI 0 CHROME PLATED SIGNAL WHITE (RAL9003) 1 NATURAL BRASS SIGNAL WHITE (RAL9003) 2 NATURAL BRASS BRASS PLATED 4 SIGNAL WHITE SIGNAL WHITE (RAL9003) (RAL9003) 9 TCHROME PLATED 1 CHROME PLATED TEMPERATURE RATINGS 135°F(57°C) 055 155°F(68°C) 082 175°F (79°C) 180 200°F (93°C) 187 286°F (141 °C) 372 480 SAMPLE ORDER LENGTHS2 0 5.50" 1 8.25" 2 18.00" 3 18.75" 4 37.25" 48.00" Notes: 1. Escutcheon Finish applies to sprinklers provided with escutcheons. 2. Dry -Type Sprinklers are furnished based upon `order Length" as measured per Figures 3 through 10, as applicable, and for:each individual sprinkler where it is to be installed. After the measurement is taken, round it to the nearest 1/4 inch increment. ` Use Prefix "I" for ISO 7-R 1 Connection (e.g., I-80-010-4-055). 38 Upright without TY3135 Escutcheon (1" NPT) (Figure 7) TABLE D SERIES DS-1 DRY -TYPE SPRINKLERS PART NUMBER SELECTION TFP510 Page 10 of 10 1400 Pennbrook Parkway, Lansdale, PA 194461 Telephone A-216-362-0700 �JJJ 02018 Johnson Controls. All rights reserved. All upecificatlons and other information shown were current as of document revision date and are subject to change without notice. loh n son NATIONAL FIRE PROTECTION ASSOCIATION and NFPA— registered tradamarks of National Fire Protection Assoclallom Controls TEFLON Is a raglat—ol bademark of DuPont tqco Fire Protection Products BLAZEMASTER CPVC Fire Sprinkler Pipe & Fittings Submittal Sheet General Description TYCO CPVC Pipe and Fittings pro- duced by Tyco Fire Protection Prod- ucts (TFPP) are designed exclusively for use in wet pipe automatic fire sprinkler systems. The TYCO CPVC Pipe and Fittings are produced from BLAZEMASTER CPVC compound that is a specially developed thermo- plastic compound composed of post chlorinated polyvinyl chloride (CPVC) resin and state of the art additives. TYCO CPVC Pipe and Fittings are easier to install than traditional steel pipe systems, and at the same time, provide superior heat resistance and strength as compared to traditional CPVC and PVC piping materials used in the plumbing trade. Various adapt- ers are available to connect CPVC pipe to metallic piping. All female pipe thread adapters have brass inserts for durability. Grooved adapters connect directly to grooved end valves and metallic pipe, with flexible grooved end couplings. NOTICE The CPVC Pipe and Fittings produced with BLAZEMASTER CPVC compound described herein must be installed and maintained in compliance with this document and with the applicable standards of the National Fire Protec- tion Association (NFPA), in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. Technical Data Sizes 3/4 Inch thru 3 Inch Maximum Working Pressure 175 psi Approvals UL and C-UL Listed FM Approved LPCB Approved NSF Certified MEA Approved City of Los Angeles (Refer to Installation Handbook IH-1900 dated June 2008 for exact listing/approval information.) Manufacture Source U.S.A. Material Pipe: ASTM F442, SDR 13.5 Fittings: ASTM F438 (Sch. 40) ASTM F439 (Sch. 80) ASTM F1970 Color Orange Worldwide I www.tyco-fire.com Contacts Installation TYCO CPVC Pipe and Fittings are to be to be installed in accordance with Installation Handbook IH-1900 dated April 2016. Page i of 2 APRIL 2016 TFP1915 TFP1915 Page 2 of 2 Care and Maintenance TYCO CPVC Pipe and Fittings are to be maintained and serviced in accordance with this section. Before closing afire protection system control valve for inspection or main- tenance work. on the fire protection system that it controls, permission to shut down the affected fire protection system must first be obtained from the proper authorities and all person- nel who may be affected by this action must be notified. After placing a fire protection system in service, notify the proper authorities and advise those responsible for moni- toring proprietary and/or central station alarms. The owner is responsible for the inspec- tion, testing, and maintenance of their fire protection system and de -vices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associa- tion (e.g., NFPA 25), in addition to the standards of any authority having juris- diction. Contact the installing contrac- tor or product manufacturer with any questions. Automatic sprinkler systems should be inspected, tested, and maintained by a qualified Inspection Service in accor- dance with local requirements and/or national codes. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 19446 1 Telephone +1-215-362-0700 Copyright © 2016 Tyco Fire Products, LP. All rights reserved. t�CO BLAZEMASTER is a trademark of The Lubrizol Corporation. Fire Protection Products FLMGUAIBD GOLD° PIPE & FIMCS NOT A DROP OF DOUBT. www.flowguardgold.com FIRE SPRINKLER SYSTEMS www.blazemaster.com SYSTEM COMPATIBLE Eliminate Questions About Chemical Compatibility The FGG/BM/CZ'" System Compatible Program is designed to test and monitor ancillary products on an ongoing basis to ensure chemical compatibility with FlowGuard Gold® and Corzan® water distribution systems and BlazeMaster® fire sprinkler systems. Over the last 50 years, billions of feet of FlowGuard Gold®, Corzan° and BlazeMaster® pipe have been successfully installed in millions of homes, condominiums, apartments, hotels and high-rise buildings around the world without incident. Occasionally there have been instances where our piping systems were damaged when coming in contact with incompatible ancillary products such as thread sealants, leak detectors, firestops, etc. Thanks to this exclusive Program, installers can simply check the label for the new FGG/BM/CZ- System Compatible mark. - This exclusive Program confirms chemical compatibility with our CPVC products: • FlowGuard Gold® pipe & fittings • BlazeMaste& pipe & fittings • Corzan® pipe & fittings Products are continually being added to the FGGBM/CZ- System Compatible program. Refer to www.flowguardgoid.com, www.blazemaster.com or www.corzancpvc.com for the most current list of compatible products. LEGAL DISCLAIMER: The FGG/BWCZ" System Compatible Program only applies to FlowGuard Gold*, BlazeMaster°, Corzane and HeallhGuard" CPVC. Other manufacturers and/or brands of CPVC piping products are not eligible and ho notcomplywitl this Program. CPVC products are made from compounds which may contain CPVC resins that have different molecular weights and different chlorine content and these factors can impact the performance of the resulting products. Addlionaly, CPVC compounds contain performance additives that affect the performance characteristics of the ancillary product. Thus, the FGGBM/CZ System Compatible program is only applicable to assess the chemical compatibility of products and materials with Lubrizol's FlowGuard Gold, BlazeMaster, Corzan, and HeafthGuard CPVC and bears no IgbiLity for any failures that may occur if the products on the FGGBM/CZ System Compatible Program are used with CPVC products other than RvxGuad Gold, BlazeMaster, Corzan and HealthGuard. C=rAz N PIPI N G SYSTEMS www.corzancpvc.com V F e'r C The following products meet the standards and are deemed to be System Compatible: Antimicrobial Coated Steel Fire Sprinkler Piping (Factory Applied) Wheatland Tube Company's MIC SHIELDT"" Coating'....www.wheatlland.com rFor steel pipe manufactured after 2122109) Antimicrobial Coating for Steel Fire Sprinkler Piping (After Market) Potter Pipe -Shield TM.......................................................www.MIC-Test.com Cutting Oil Ace Transul-Kut 3200 Cutting Oil..................................www.lube-tech.com CL-Free PLUS Thread Oil............................................www.achemists.com FPPI' ThreadFitc Cutting Oil.....................................................www.fppi.com Lubsoil Lubscut 3462 Lite Oil...............................................www.tulco.com Ridgid® Endura-ClearTM........................................................www.ridgid.com Tuf-Cut Clear Thread Cutting Oil.........................................www.tulco.com Whitlam Thread -Cut Plus.............................................www.jcwhitiam.com Leak Detectors megabubblec Leak Detector........................................www.herchem.com RectorSealTm Better Bubble m.....................................www.rectorseal.com Firestop Sealants A/D FIREBARRIER Intumescent Sealant............................www.adfire.com A/D FIREBARRIER Silicone* (red & gray)............................www.adfire.com A/D FIREBARRIER Silicone SL* (red & gray)........................www.adfire.com BioStopc 350i & 500+............................................www.biofireshield.com BioStopc BF 150+....................................................www.biofireshield.com BlazeMasterc Caulk & Walk.....................................www.blazemaster.com Hiltic CP 601S Elastic Firestop Sealant*..........................www.us.hilti.com Hiltic CP 604 Self -Leveling Firestop Sealant*.......................www.us.hilti.com Hiltic FS-One.....................................................................www.us.hilti.com Metacaulkc 350i & 1000..........__ ................................www.rectorseal.com Metacaulkc MC 150+..............................................www.rectorseal.com STI PENSILc300*........................................................www.stifirestop.com STI SpecSealc LCI Intumescent Firestop Sealant .........www.stifirestop.com STI SpecSeal® Series SIL300......................................www.stifirestop.com STI WF300 Firestop Caulk.........................................www.stifirestop.com Tremco Fyre-Caulk.............................................www.tremcofirestop.com TREMStopTM Fyre-Sil..........................................www.tremcofirestop.com TREMStopTM Fyre-Sil SL....................................www.tremcofirestop.com TREMstopTM IA.................................................wwwAremcofirestop.com TREMstopT/ IA+................................................www.tremcofirestop.com 3M Fire Barrier Water Tight Sealant 1000 NS* ............www.3m.com/firestop 3M Fire Barrier Water Tight Sealant 1003 SL* ............www.3m.com/firestop 3M IC 15 WB+ Firestop............................................www.3m.com/firestop 3M 3000 WT Firestop.............................................www.3m.com/firestop rSificone based firestop) Firestop Wraps BioStopTM Wrap Strip............................................www.biofireshield.com Hillis CP 648-S / CP 648-E.................................................www.us.hilti.com MetacauleWrap Strip................................................www.rectorseal.com Firestop Cast -In Devices Bio FireshieldTM Cast -In -Place Firestop Device .......www.biofireshield.com Hiltic CP 680-N / CP 680-P.................................................www.us.hilti.com Hilti' Top Seal Plug.............................................................www.us.hilti.com HMO Water Barrier Module.................................................www.us.hilti.com Metacaulk' Cast -In -Place Firestop Device..................www.rectorseal.com Presealed Systems' Hydro Flame...............www.presealedsystems.com Presealed Systems' HydroPreseal...............www.presealedsystems.com ProSet Systems White ProSeal Plug....................www.prosetsystems.com STI SpecSeal Cast -In Firestop Device ..........................www.stifirestop.com Firestop Collars BiostopTM Pipe Collar............................................www.biofireshieId.com Hiltic CP 643N..................................................................www.us.hilti.com Metacaulkc Pipe Collar...............................................www.rectorseal.com Termiticide / Insecticide Bora-Care®.................................................................www.nisuscorp.com Thread Sealants Anti -Seize Technology SlickorP GTS GoIdT"" ................www.antiseize.com Black Swan's Big White Pipe Joint Compound .....www.blackswanmfg.com FPPI® PipeFitc......................................................................www.fppi.com IPS® Blue Seal...................................................................www.ipscorp.com IPS® White Seal Plus..........................................................www.ipscorp.com Jet -Lubec TFWTM...................................................... _ NVAr w.jetlube.com LA-COc Leak -Titer Blue.........................................................www.laco.com LA -COO Slic-Titec Paste.......................................................www.laco.com Lyncar ProSeal Plus............................................................www.lyncar.com Oateyc Great Whitec.............................................................www.oatey.com Permabondc LH056.................................................www.perFnabond.com pro dopeTm Thread Sealant.........................................www.herchem.com RectorSealTm T Plus 2..............................................._Www.rectorseal.com Whitlam Power Seal Plus.............................................www.jcwhitlam.com Freeze Protection FireFightercGL- Ready-To-Use*............................www.noblecompany.com FSS ProTect GL - Pre-Mix'.....................................www.huguenotiabs.com rGlycerin for fire sprinklers) Insulation* ArcticFleklm...............................................www.nomacoinsulation.com Econotherme..............................................www.nomacoinsulation.com Ecoshield'.................................................www.nomacoinsulation.com Frost King.........................:...........................www.nomacoinsulation.com ImcoLock'...................................................www.nomacoinsulation.com Imcoshieldc..............................................www.nomacoinsulation.com Nomagardc..................................................www.nomacoinsulation.com Nomalockc...............................................www.nomacoinsulation.com therma-celc...................................................www.nomacoinsulation.com Tundra......................................................................www.tundratoam.com Tundra Plus..............................................................www.tundrafoam.com Tundra Seal..............................................................www.tundrafoam.com ('insulation products listed are made of polyolefm) Seismic / Expansion Devices Loos & Co. - Seismic Wire Rope/ CableTm Bracing ................................... www.earthquakebrace.com Metraflexc Fireloopc Expansion Joint for Fire Sprinkler Systems ...................................... www.fireloopJnfo System Accessories FlexHeadc Fire Sprinkler Connections...........................www.flexhead.com Sioux Chief CPVC Transition Fittings..........................www.siouxchief.com Gasket & Gasket Lubricant FPPIc LubeFit' Gasket Lubricant............................................www.fppi.com Garlock® Stress Savers XP Gasket....................................www.garlock.com LA-COe Lubri-Joint' Water Dispersible Gasket Lubricant ........www.laco.com Phoenix'" 27-A Water Dispersible Pipe Joint Lubricant...........................................www.jtmproductsinc.net Whitlam Quick Slip Plus..................................................www.joinpipe.com Detergents Alconoxc..............................................................www.alconox.com LEGAL DISCLAIMER: The FGG/BM/CZ" System Compatible Program only applies to FlowGuard Gold®, BlazeMaster*, Conan' and tleallhGuard" CPVC. Other manufacturers and/or brands of CPVC piping products are not eligible and do not comply with this Program. CPVC products are made from compounds which may contain CPVC resins that have different molecular weights and different chlorine content and these factors can impact the performance of the resulting products. Additionally, CPVC compounds contain performance addilives that effect the performance characteristics of the ancillary product. Thus, the FGG/BNi/CZ System Compatible program is only applicable to assess the chemical compatailey of products and materials with Lubrizol's FbwGuard Gold, BlazeMaste, Coran, and HeaahGuard CPVC and bears no liability for any failures that may occur if the products on the FGGBM/CZ System Compatible Program are used with CPVC products other Ran FldwGuard Gold, BlazeMasler, Corzan and HeathGuard. n a 1 01 C i P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 510 CPVC - COPPER - STEEL HANGER/RESTRAINER SIZE - SYSTEM PIPE: 3/4" thru 3" MATERIAL - Carbon Steel. FINISH - Mil. Galvanized. LISTING/APPROVAL - e '" 203 - EX 4231, EX 2551 UM ALTERNATIVE FOR #500 Pipe Strap 510 Fastener SIZE Dim. rL - rL 3/4 2.125 1 2.312 1 1/4 3.170 1 112 3.400 2 4.010 2 1 /2 4.320 3 5.320 FUNCTION - Support horizontal piping: CPVC, Copper or Steel. Hanger for steel pipe at 151 spacing per NFPA 13. Size 3/4" - 2" Prevents upward movement of pipe from pendent sprinkler discharge. Stabilize vertical piping. INSTALLATION - Per these instructions including NFPA 13, 13R, 13D and CPVC manufacturers instructions. Install on horizontal or vertical mounting surface. ASSEMBLY/ATTACHMENT - See drawings. SPECIAL c@us FASTENERS PER NFPA 13 - See table. a� FEATURES * Offset edge eliminates abrasion. * Retainer dimples secure hanger to pipe during installation. ORDERING - Part # and pipe size. Hanj °mot " MOUNTING FASTENERS Pipe Wood Wood - Th. 5/8"Gyp Steel - Min. IS GA. CPVC #905 or #10 xl SMS #14 x l 1/2 SMS or 1/4 x 2 LS #14 or 1/4 Tek Steel/Copper #14 xl 1/2 SMS or l/4 xl 1/2 LS #14 x 2 SMS or 1/4 x 2 LS #14 or 1/4 Tek SMS = Shen Mnal Screw LS = Lag Screw T kTGyps— B°°`" AFCON #905 screw - custom 5/16" hex head. Restraint Specific AFCON products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER - AFCON will NOT warrant against the failure of its products when used in combination with other products, pans or systems not manufactured or sold byAFCON AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when non-AFCON products have been, or are used. ibilize 1/16 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 511 CPVC - COPPER SIDE MOUNT HANGER SIZE - SYSTEM PIPE: 3/4" thru 2" MATERIAL - Carbon Steel. FINISH - Mil. Galvanized. LISTING/APPROVAL - `1 mo°s 203 - EX 4231, EX 2551 FUNCTION - Support horizontal piping - CPVC or Copper. Stabilize vertical piping. INSTALLATION - Per these instructions including NFPA 13, 13R, 13D and CPVC manufacturers instructions. Install on vertical mounting surface. ASSEMBLY/ATTACHMENT - See drawings. SPECIAL a®'s FASTENERS PER NFPA 13 - See table. rnr[o FEATURES * Offset edge eliminates abrasion. * Retainer dimples secure hanger to pipe during installation. ORDERING - Part # and pipe size. '§R- MOUNTING FASTENERS Pipe Wood Steel - Mi.. 18 GA. CPVC #4050r#lox1SMs 1 #14or1/4Tek Copper #405or#10x1SMS #14or1/4Tek SMs = Shut Me1a1 Sa TA --TA S— AFCON#905 screw - custom 5/16" hex head. Side View - For Drawings Below Hanger - Wood Stud Hanger - Metal Stud Specific AFCONproducts are exclusively designed to be compatible ONLY with other AFCONproducts including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER - AFCONwill NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by AFCON. AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when non-AFCON products have been, or are used. t 1/16 i P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 514 OFFSET HANGER & RESTRAINER CPVC - COPPER - STEEL SIZE - SYSTEM PIPE: 3/4" thru 2" MATERIAL - Carbon Steel. FINISH - Mil. Galvanized. LISTING/APPROVAL - t rno a: urn. - EX 4231, EX 2551 ze 314 - 1 114: Fastener )acing fits on wood 2 x 4 Installation - Backino Nut Hanger = 1 - at top fastener Restraint = 2 - on each fastene PATENT - No. 6,648,278. FUNCTION - Hanger for support of CPVC or copper pipe. Hanger for steel pipe at 15' spacing per NFPA 13. Seismic restraint - Both horizontal and vertical. Vertical restraint for sprinkler discharge. Hanaer/ INSTALLATION - Per these instructions Restraine including NFPA 13, 13R, 13D and CPVC manufacturers. Snap over pipe then squeeze strap back allowing pipe to slide freely. When fastener threads are exposed through wood, install backing nut - See drawing. ASSEMBLY/ATTACHMENT - See drawings. SPECIAL -@- FASTENERS PER NFPA 13 - See table. usno FEATURES * 1 1/2" Offset * Common center -line for 3/4" and 1". * Offset edge eliminates abrasion. ORDERING - Part # and pipe size. AFCON #906 backing nut sold separately. e@t " MOUNTING FASTENERS Pipe Wood Wood - Thru 5/8" Gyp Steel - Mtn. 18 GA. CPVC 4905 or#10 xl SMS #]4x2 SMS or 1/4x2LS #14or1/4Tck Steel/Copper #14 xl 1/2 SMS or 1/4 xl 1/2 LS #14 x 2 SMS or 1/4 x 2 LS #14 or 1/4 Tck SMS = Sheet Metal Screw LS = Lag Screw Gyp= Gypsum Board Tek=Tek Screw AFCON#905 screw - custom 5/16" hex head. Hanaer/Restrainer Hanaer/Restrainer bilize Specific AFCONproducts are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER - AFCONwill NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by AFCON. AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when non-AFCON products have been, or are used. 1/16 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 904 C.P.V.C. SCREW For use with U.L. Listed AFCON Products #515 and 519. 3/8" Hex Head 905 C.P.V.C. SCREW For use with U.L. Listed AFCON Products #510, 511, 512, 513 and 514. 5/16" Hex Head 906 BACKING NUT For use with AFCON #905 screw as required by product installation. OExample: See #514 engineering sheet 8/14 : : JILWJBoa ; soz ® SLOW CLOSE BRONZE BUTTERFLY VALVE ONE-PIECE, FULL -PORT 175 PSI FM 0 s THREADED ENDS annnoveo DIMENSIONS Valve Size DIM 1" 1-114" ,1412" 2" 2-112" A 2.13 2.63 2.88 3.25 4.13 B' 3.16 3.31 3.41 3.63 3.82 C 1.56 1.94 2.19 2.75 3.19 D 1.72 2.11 2.38 3.07 3.50 X 4.16 4.16 4.51 4.76 4.66 K .66 .73 .73 .79 1.18 L .83 '90 .10 1,41 1.29 M-40' . 1.10 1.38 1.61 2.07 2.47 M-80' . .96 1.28 1.50 1.94 2.32 N.W 2.25 2.00 2.50 2.25 10.00 1.13 1.25 1.41 1.69 1.75 ALL DIMENSIONS -INCHES Pertains to SB•SC1 DO ony. ' Pertains to BB-SCS02 only. ' M-40 ARE DIMENSIONS USING SCHEDULE 40 PIPE ' M-80 ARE DIMENSIONS USING SCHEDULE 80 PIPE ' N-40 IS FLOW RESISTANCE EXPRESSEDIN EQUIVALENT LENGTH OF SCHEDULE 40 PIPE ' W IS THE WRENCH MAKE-UP LENGTH FEATURES • Slow opening and closing • Quarter turn operation • Water Hammer elimination • Optional internal tamper switch (Indoor/Outdoor use). - Signals disc movement - Factory or Field installation - 10 Amp 1115 VAC-60 Hz - 0.5 Amp / 28 VDC • Grooved Ends Available in Sizes 2" and 2-1/2' 1 " 2.11i Approved by: NYC Board of Stds. & Appeals, Cat. #996-81-SM ((175ps' 72G-83-SA (350 & 500 psi) BB-SC100 Sizes 1 ", 1-1 /4", 1-1 /2", 2", 2-1 i 2" BB-SCS02 (includes Switch) The information presented on this sheet is correct at the time of publication. Milwaukee Valve reserves the right to change design, and/or material specifications without notice. For the most current information access www.milwaukeevalve.com LISTED FIRE ALARM CONTROL PANEL SUPERVISORY CIRCUIT WIRING DIAGRAM (SWITCH POSITION VALVE FULL OPEN) SWITCH 1: DUAL LEADS Nc la, Com ' RED SWITCH 2: SINGLE LEADS TO NEXT INDICATOR OR END OF LINE RESISTOR ORANGE AUXILIARY NC EQUIPMENT VOLTAGE BLUE SOURCE °OA" NO YELLOW Green Lead provided is ground for switch housing Switch Rating: 10AMP/ 115 VAC ,5 AMP/28 VDC Cap unused leads with wire nuts and tuck Inside junction box (not provided) NOTE: Valves incorporating supervisory tamper switches are for indoor use onik SUPERVISORY TAMPER SWITCH Milwaukee Valve Company 2375 South Burrell Street Milwaukee, Wisconsin 53207-1592 Telephone 414/744-5240 FAX 414/744-5840 ULB8.SC040300.cdr 112" ELECTRICAL CONDUIT UL LISTED JUCTION BOX MILWAUKEE VALVE POTTER ® The Symbol of Protection RD13 RISER UL, CUL, CSFM listed, and CE Marked Service Pressure: 175 PSI (12,07 BAR) - UL Flow Sensitivity Range for Signal: 4-10 GPM (15-38 LPM) - UL Maximum Surge: 18 FPS (5.5 MPS) Contact Ratings: Two sets of SPDT (Form C) 10.0 Amps at 125/250V AC 2.0 Amps at 30V DC Resistive 10 in Amps min. at 24V DC Conduit Entrances: Two knockouts provided for 1/2" conduit. Environmental Specifications: Temperature range: 40°F - 120°F (4.5'C - 49°C) - UL Replacement VSR-SG: Stock number 1144460 Service Use: Automatic Sprinkler NFPA-13 One or two family dwelling NFPA-13D Residential occupancy up to four stories NFPA-13R 1 National Fire Alarm Code NFPA-72 IREI British Standard BS9251 Optional: Cover Tamper Switch Kit, stock number 0090148 Replaceable Components: Retard/Switch Assembly, stock number 1029030 Gauge and flow switch shipped loose in box. Models: V RD13 Riser PN 1119067 1 1/4" RD13 Riser PN 1119077 1 1/2" RD13 Riser PN 1119087 2" RD13 Riser PN 1119097 The RD13 Riser (with NPT connectors) is constructed from Listed CPVC products suitable for fire sprinkler services subject to the limitations and installation requirements of Flameguard(& CPVC pipe and Spears® CPVC fittings. The RD13 Riser incorporates a VSR-SG flow switch, gauge, and drain/ test valve. The VSR-SG flow switch is equipped with union connection to facilitate the installation and removal of the switch in confined spaces. Installation Using appropriate fittings connect the main water supply to the bottom of the riser and the drain connection to an adecquate drain location capable of handling the drain discharge. The riser can be mounted in the horizontal or vertical position. Direction offlow is indicated in Fig. 1. The waterflow switch must be located on the top or on the side of the pipe when installed in the horizontal position. This will prevent debris from entering the throat of the waterflow switch which could interfere with proper operation. The 1" NPT adaptor coupling is shipped loose and may be used to ease installation. Following CPVC manufacturer's instructions for preparation and gluing of CPVC piping systems, glue the main riser to the main supply line for the sprinkler heads. Note: All glued connections must be completed and cured before the flowswitch is installed. Threaded Connections A thread sealant shall be used in making threaded connections. Teflon® thread tape is the recommended sealant. Some thread sealants other than Teflon thread tape contain solvents or other materials that may be damaging to CPVC. For other types of thread sealants, which have been specifically investigated and confirmed to be "System Compatible", refer to www. spearsmfg.com. Attach gauge to riser. Apply Teflona) tape to male fitting of gauge only. See Fig 1. Check to make sure the proper paddle is installed on the switch. (Paddle size must match the riser pipe size and Tee manufacture.) Install the flow switch to the RD13 Riser. Verify that the o-ring is properly positioned in its groove. Hand tighten the nut to the union after orienting • Risk of explosion. Not for use in hazardous locations. Serious injury or death could result. the flow switch in the appropriate direction to detect waterflow. The paddle must not rub the inside of the Tee or bind in any way. The stem should move freely when operated by hand. See Fig. 1. Note: Do not leave switch cover off for an extended period of time. Orientation 6. Side of flow switch must be perpendicular with the riser piping. See Fig. 3. Inspection and Testing The frequency of inspection and testing for the Model VSR-SG and its associated protective monitoring system, should be in accordance with applicable Codes and Standards and/or the authority having jurisdiction (manufacturer recommends quarterly or more frequently.) If provided, the inspector's test valve (usually located at the end of the most remote branch line) should be used for test purposes. If there is no remote inspection test connection; a short length of hose may be connected to the discharge of the 1" drain line valve, or if the drain line is connected to a drain such as a slop sink or storm drain that will sufficiently handle the discharge of the main drain valve. The drain valve can be used to test the operation ofthe VSR-SG switch. A minimum flow of 10 GPM (38 LPM) is required to activate this switch. An orifice equal to the smallest sprinkler head orifice used in the system shall be attached to the drain line for testing purposes. Maintenance A CAUTION The VSR-SG waterflow, switch should provide years of trouble -free service. The retard and switch assembly are easily field replaceable. In the Do not over -tighten the union nut, hand tighten only. Use of a wrench may unlikely event that either component does not perform properly, please order cause damage to the union nut. replacement retard switch assembly stock number 1029030. There is no maintenance required, only periodic testing and inspection. Potter Electric Signal Company, LLC • St. Louis, MO • Cust Service: 866-572-3005 -Tech Support: 866-956-0988 • Canada 888-882-1833 • www.pottersignal.com PRINTED IN USA MFG. #5401152 - REV J PAGE 1 OF 2 02/12 (E)POTTER ® The Symbol of Protection RD13 RISER Removal • To prevent accidental water damage, all control valves should be shut tight and the system completely drained before waterflow detectors are removed or replaced. • Turn off electrical power to the detector, then disconnect wiring. • Loosen nut on union fitting. • Lift detector clear of pipe. Fig. I OPTIONAL COVER Retard Adjustment 77AMPERSWITCH The delay can be adjusted by rotating the retard adjustment knob from 0 to the max setting (60-90 seconds). The time delay should be set at the DO NOT LEAVE COVER minimum required to prevent false alarms. RETARD OFF FOR EXTENDED ADJUSTING PERIOD OF TIME: KNOB 'J? MOLTITSOARROW DIRECTION OF ON BASE POINTS IN WATERFLOW 1 MALE FITTING ON WATFRROW O O ALL SIZES RISER MAY BE 1",1 114", DINGY. I5I5-1 I DWG, J1063-3 1 I/T-, OR 2- Important: The paddles have raised lettering that show the pipe size and the TEE manufacturer they are to be used with. The proper paddle must be used. DIRECTIONLOW WATERFLOW The paddle must be properly attached and the screw that holds the paddle must be securely tightened. Fig. 2 Dimensions *(See Chart Below) I NPi ADAPTER GAUGE V NPT DRAIN VALVE I"NPT COUPLING (SHIPPED LOOSE) uv✓G# 1152-2 Fig. 3 Orientation DWG# 1152-3 Flow switch must be properly orientated. Side of cover must be perpendicular with the pipe. Improper orientation could delay or prevent *RD13 Risers (ASSEMBLED DIMENSIONS) Riser Size Model Number Part Number Dimension "A" Dimension 'B" Dimension "C" Dimension "D" (in) (mm.) (in) (Min.) (in) (mm) (in) (mm) 1" RD13-100-1 1119067 16 406 15 3/4 400 12 1/4 311 10 1/2 267 1 1/4" RD13-125-1 1119077 16 5/8 422 16 1/2 419 12 1/2 318 10 5/8 270 1 1 /2" RD13-150-1 1119087 N/A N/A 16 3/4 425 12 3/4 324 10 3/4 273 2" RD13-200-1 1119097 1 N/A I N/A 18 1/4 464 13 3/8 340 11 1/8 283 PRINTED IN USA MFG. 45401152 - REV J PAGE 2 OF 2 02/ 12 BELLS(DPOTTER SymbolThe of ProtectioniMBA-DC O* 1 These vibrating type bells are designed for use as fire, burglar or general signaling devices. They have low power consumption and high decibel ratings. The unit mounts on a standard 4" (101mm) square electrical box for indoor use or on a model BBK-1 weatherproof backbox or BBX-1 deep weatherproof backbox for outdoor applications. Weatherproof backbox model BBK-1, Stock No. 1500001. UL, ULC, and FM Approved Sizes Available: 6" (150mm), 8" (200mm) and 10" (250mm) Voltages Available: 24VAC 120VAC 12VDC (10.2 to 15.6) Polarized 24VDC (20.4 to 31.2) Polarized Service Use: Fire Alarm General Signaling Burglar Alarm Environment: Indoor or outdoor use (See Note 1) -400 to 150OF (401 to 66°C) (Outdoor use requires weatherproof backbox.) Termination: AC Bells - 4 No. 18 AWG stranded wires DC Bells - Terminal strip Finish: Red powder coating Optional: Model BBK-1 weatherproof backbox Model BBX-1 deep weatherproof backbox Notes: 1. Minimum dB ratings are calculated from integrated sound pressure measurements made at Underwriters Laboratories as specified in UL Standard 464. UL temperature range is -30' to 150°F (-34° to 66*C). 2. Typical dB ratings are calculated from measurements made with a conventional sound level meter and are indicative of output levels in an actual installation. 3. ULC only applies to MBA DC bells. Size inches (mm) Voltage Model Number Stock Number Current (Max.) Typical dB at 10 ft. (3m) (2) Minimum dB at 10 ft. (3m) (1) 6 (150) 12VDC MBA126 1750070 .12A 85 76 8 (200) 12VDC MBA128 1750080 .12A 90 77 10 (250) 1 12VDC MBA1210 1750060 .12A 92 78 6 (150) 24VDC MBA246 1750100 .06A 87 77 8 (200) 24VDC MBA248 1750110 .06A 91 79 10 (250) 24VDC MBA2410 1750090 .06A 94 80 6 (150) 24VAC PBA246 1806024* .17A 91 78 8 (200) 24VAC PBA248 1808024* .17A 94 77 10 (250) 24VAC PBA2410 1810024* .17A 94 78 6 (150) 120VAC PBA1206 1806120* .05A 92 83 8 (200) 120VAC PBA1208 1808120* .05A 1 99 1 84 ]0(250) 120VAC PBA12010 1810120* .05A 99 86 All DC bells are polarized and have built-in transient protection. * Does not have ULC listing. I AWARNING In outdoor or wet installations, bell must be mounted with weatherproof backbox, BBK-1 or BBX-1. Standard electrical boxes will not provide a weatherproof enclosure. If the bell and/or assembly is exposed to moisture, it may fail or create an electrical hazard. Potter Electric Signal Company, LLC - 2081 Craig Road, St. Louis, MO, 63146-4161- Phone: 800-325-3936/Canada 888-882-1833 - www.pottersignal.com PRINTED IN USA MFG. #5400776 - REV Y PAGE 1 OF 2 5/08 (DPOTTER The Symbol of Protection BELLS PBA-AC & MBA -DC Bells Dimensions Inches (mm) Wiring (rear view) Fig. 1 Fig. 3 A.C. BELLS 101, WHITE (IN) WHITE (OUT) (2s0) FROM CONTROL (200) PANEL OR (150) �� , PRECEDING BELL `fi_ J BLACK (IN) C.LIACK -r \\ // CAUTION: WHEN ELECTRICAL SUPERVISION IS REQUIRED USE IN AND OUT LEADS AS SHOWN. 2 11/16" 68 DWG# 7761 NOTES: 1. WHEN USING AC BELLS,TERMINATE EACH EXTRA WIRE SEPARATELY AFTER LAST BELL. 2. END -OF -LINE. RESISTOR IS NOT REQUIRED ON AC BELLS. Weatherproof Backbox Dimensions Inches (mm) Fig. 2 Box has one threaded 1 /2" conduit entrance 3 3/8" 5" (86) (127) 1 L?-J.?- -1 1 - 3 3/IT' (86) 4 1/4' (108) DWG#776-2 - 7763 Installation 1. The bell shall be installed in accordance with NFPA 13, 72, or local AHJ. The top of the device shall be no less than 90" AFF and not less than 6" below the ceiling. 2. Remove the gong. 3. Connect wiring (see Fig. 3). 4. Mount bell mechanism to backbox (bell mechanism must be mounted with the striker pointing down). 5. Reinstall the gong (be sure that the gong positioning pin, in the mechanism housing, is in the hole in the gong). 6. Test all bells for proper operation and observe that they can be heard where required (bells must be heard in all areas as designated by the authority having jurisdiction). AWARNING Failure to install striker down will prevent bell from operating. PRINTED IN USA MFG. #5400776 - REV Y PAGE 2 OF 2 5108 4 Location D9 Poly UG iy Others no r BUILDIN b 2 1 { °�1 9 UNITS + OFFICE GARAGE 2ND FLOOR FF= 457.331, 1ST FLOOR FF�lg 448.001 1. GARAGE L W5 J_­ REMOVE EX. UTILITY POLE & AERIAL 1� X11 WIRES (BY PSE) L N 89'07'04" _W 12514 SITE PLAN 101-0" SCALE: 1" = 10'- 0" 2ND FLOOR FF= 457.00 IST FLOOR FF= 447.00 a� A 46 NEW 1.5- WATER METER — PER SHEET 2 - WATER PLAN New 2" Fire DCDA in meter box per Standard Detail 12" Poly UG by Others Zx Ir Hanger No. 09W pip. Strap Hangar No. 19W Mett Pipe Hangar Hanger No. 17W Pipe strap SPRINKLER RISER STOF - 2 4blier 0' -6" from Back Wall .z roiy u%v oy vicine"F-t--.1 Ir ans ons ® 0*-M= mom RISER PLAN SCALE: 1/2" = 1' - 0" FIRE PROTECTION FACIUTIES--/ SHALL NOT BE OBSTRUCTED By LANDSCAPE PLANTING NOW OR IN FUTURE. N 00-52'56" E 20M NEW I" IRRIGATION METER PER SHEET 2 - WATER PLAN MAXIMUM SUPPORT SPACING FOR CPVC PIPING PIPE SIZE FEET METER 3/4" 5-1/2 11.7) V 6 (1:8) 1-1/4" 6-1/2 ` 2.0) 1-1/2" 7 (2.1) 2" 8 (2.4) MOOREFP UG NEW 10' WATER ESMT. TO OVWWD It - ­'LA-2, - NYLANU APARTMENTS "MFPAA 6 fir..T _X1 SITE Z J SPRIFICATIONS 3R AH3: ........................ Edmonds Fire Marshal Owner/Lessee: Roy Gursll, 5 210 42 -5502 Related Permit No:... BLD20190998 5909 - 164th St. SW Occupancy Type:...... R-2 L9 Z LL U. 0 D Lynnwood, WA 98037 Construction Type: ... V-13 Fully Sprinklered Parcel No: ........... 00463303200303 No. Of Stories:.........2 Legal Description: General Description; Two new apartment HANBURYS SOUND VIEW TRS BLK 032 D-03 - N IN buildings with 19 units 145FT OF W 30FT OF LOT 3 ALSO N 145FT OF E A 00 total. Building I Is 70FT OF LOT 4ALSO N 12OFr OF LOT 4 EXC E 7,813 ft2 1 X I with two 70FT ALSO IN 120Fr OF E 1/2 OF LOT 5 EXC S V_ A stories and Building2 SFT OF N 145FT` OF W 6OFT OF E 70FT SO LOT 4 IPROPOSED is 9,245 ft2 with three PER BLA 002-94 REC AF NO 9408050454 FIRE FLOW: stories. POWER SECONDARY PAD MOUNT J Fire flow model provided by Cody -Lee A. Gray, Olympic View Water & Sewer District 12/6119 from TRANSFORMER node F-2456 located at the hydrant on site. With a static pressure of 63 PSI, the 8 In. main (IF NECESSARY) extension can provide 1,700 GPM with 20 PSI residual pressure. SYSTEM SPECIFICATIONS 0 BUILDING CODE: 2015 IBC with WA State Amendments -------- A, SYSTEM TYPE: 2016 NFPA 13R Wet Sprinkler r System �l TaMd.: SPRINKLER COVERAGE: with Dwelling Compartments D 'g "om 16'-0" X 16, max/hd. Al N) X256,ft2 Dwelling Compartments with 2 Heads or Less: 2C - 20 -0. 400 W. Storage, Mechanical, Electrical, Sprinkler Riser: 130 li max. per head. C SPRINKLER SPACING: covered Patios: 225 ft- max. per nendent 196 ft2 max per sidewall Nod NEW ff WATER ESMT TO OVWWD 8c- ......... JY REMOVE EX UTIIJTY POLE & AERIAL WIRES (BY PSE) �_ Hydrant -2456 /--NIW 15' ESMT. To OVWWD S7 DOMESTIC METER _AA TR PLAIN 3) 7"04" W 60.00 1---4-Way Sway Brace at Top of Riser CPVC .!=Way pressure relief valve w/ 300# gauge r—=1" Drain to Sanitary Drain —plow switch wired to bell by others __--2" x 1'40" SCH 40 by others ice with Plug to accommod card flow test. Block out l'-O" x 1'-1111" area to protect stub. Slab with min. 2" gap 2" Poly RISER ELEVATION, SCALE: 1/2" = 1' - 0" C3) Residential Pendents: Dry Barrel Pendants: Dry Barrel Sidewalls: DENNY'S 167 20' max. between heads. 15'-0" max. between heads. 14'-0" max. between heads. 8 / 10' max. from any wall. 7'-6" max. from any wall. T-O" max. from adjacent wall. TA EDMONDS LLC 843 244TH ST. S 8'-0" min. between heads. W-O" min. between heads. 6'-0" min. between heads. W SPRINKLER DETAILS: 4"-12" deflector to ceiling. 'ARCEL 004633032001102 U) r semi -recessed residential pendants are used throughout Interior. 5.6K skirt & sleeve 6�,! Sr standard spray quick response dry barrel pendants are used on first floor covered patios. 5.6K .- -EX. 10' SEWER skirt & sleeve standard spray quick response dry barrel sidewalls are used on upper floor A EASEMENT covered patios. > AFN# 1988205, =P� D I NO EX. PIPE. HAZARD CLASSIFICATION: ESVIT TO BE Dwellings: Residential at 0.05 density. RELINQUISHED Storage, Mechanical, Electrical, Sprinkler Riser: Ordinary Hazard Group I at 0.15 density. d`lI BY Qvlimi Covered Patios: Light Hazard at 0.1 density. d PIPING DETAILS: u. All aboveground piping denoted with only the pipe diameter to be CPVC plastic with CPVC fittings E except as noted on the riser detail. SUPPLY: System supply Is coming from a new B" water main extension to the new hydrant located on dd site. 2" poly runs approx. 10' from tee to a new 2" DCDA located In vault per standard detail -141. 2" poly underground continues approx. 116'to a 2" male threaded adapter left by - E E WA [1- others in the fire sprinkler riser mom In Building 2 and approx. 142' to Building 1. 4" Stom FDC 1 to be located In parking lot per Civil Plan C4.1. All underground, Including FDC, by others. Moore Fire's scope of work to begin at 2" male threaded adapter left by others. GENERAL NOTES AND LIABILITY: 0 a a cy All system piping Is to be supported per manufacturer's specifications and Is to be secured to 5 prevent lateral movement. Pipe Is to be secured to prevent sprinkler head movement. Moore Fire Protection's warranty of work does not cover any damage due to freeze related problems. Wet piping shall be protected against temperatures below 40 degrees Fahrenheit. :2 F_ d .5 in Insulation Installed for this purpose shall be located on the cold side of the pipe only with no a Insulation on the warm side of the pipe facing the heated Interior. Coordinate with general 7�i .4 2E CL 7 R and/or Insulation contractor. All Insulation to be by others. in W FIRE PROTECTION FACILITIES Moore Fire Protection shall not be responsible for the ability of the structure to adequately SHALL NOT BE OBSTRUCTED support the fire sprinkler system or any appurtenances thereof. 0 BY LANDSCAPE PLANTINa\ NOW OR IN FUTURE , Owner is responsible for the periodic Inspection, testing and maintenance of the water based fire CLEARANCE', MAINTAIN 3-Ff protection system(s) In accordance with the requirements of NFPA 25. a- 41 AROUND FOG. 4" Storz CODEQUICK REFERENCES A 30* FDC 6.6 LOCATION OF SPRINKLERS: 6.6.1 Sprinklers shall be installed in all areas except where omission Is permitted by 6.6.2 `through 6.6.7. 8 $ 6.6.2- Sprinklers shall not be required in bathrooms where the bathroom area does not exceed M $ 40 55 W. E 6.6.3 Except where specified in 6.6.4, sprinklers shall not be required in clothes closets, linen 1, Oosets, and pantries within dwelling units that meet all of the following conditions: (1) The area 00 of the space does not exceed 24 ft-. (2) The walls and ceilings are surfaced with noncombustible or limited -combustible materials as defined by NFPA 220, 6.6.4- Sprinklers shall be installed in any closet used for heating or air-conditioning equipment, washers, dryers, or water heaters except as permitted by 6.6.7. 6.6.5* Except as provided for In 6.6.5.1, sprinklers shall not be required In any porches, C balconies, corridors, carports, Porte cocheres, and stairs that are open and attached. 6.6.6- Sprinklers shall not be required In attics, penthouse equipment rooms, elevator machine rooms, concealed spaces dedicated exclusively to and containing only dwelling unit ventilation equipment, crawl spaces, floor/ceiling spaces, elevator shafts where the elevator Installation to complies with ANSI A17.1, safety code for elevators and escalators, and other concealed spaces 1% that are not Intended for living purposes or storage and do not contain fuel -fired equipment. 6.6.7 Sprinklers shall not be required in closets (regardless of size) on exterior balconies and exterior breezeways/corridors, regardless of size, as long as the closet does not have doors or unprotected penetrations directly Into the dwelling unit. 6.619.2- Sprinklers shall not be required underneath stair risers in dwelling units where the U.1 r4 ran rn ID ft o, walls and ceilings are surfaced with noncombustible or limited -combustible finishes. Z ID V of ;iF 7.2 DESIGN CRITERIA -.OUTSIDE DWELLING UNIT- 7.2.1 Areas outside the dwelling unit shall comply with Section 7.2, 7,2.2 The number of design sprinklers for a corridor or breezeway outside the d < N welling unit shall iT) D� Include up to the four most hydraulically demanding adjacent sprinklers. 111 7.2.3 The design discharge and design area criteria for areas protected by quick -response CID 3: E -0 0 4 sprinklers shall comply with NFPA 13 except as allowed by 7.2.3.1. 0 < 20 U) 7.2.3.1 For compartments 500 ft2 or less that meet all of the following conditions and are to protected with quick -response sprinklers, the design area shall be permitted to be limited to the = (<y number of sprinklers In the compartment but shall not exceed four sprinklers: < in M 8 LLJ EX, SEWS EASEVENT (1) The area is protected with 30 minute -rated construction. AFN# 1988205 :J U) T g w c, (2) The sprinklers are spaced at 225 ft2 maximum for light hazard, 130 ft2 maximum for Cy— 5 t) N r ILI ordinary hazard, o in accordance with their listing. — 1;; EX,. (3) Openings have a lintel depth at least 8 in. in depth. 0 Z UNDERGROUND ACCESS & (4) The total area of openings, excluding any overhead doom that open to the exterior, does no in Or ES!J7 POWER, TELE It n ZE INUTILITY 1. exceed 50 ft2 for each compartment. CAIV BY TEKIN (5) Discharge densities are in accordance with NFPA 13. I. DEVELOPMENT 7.2.4 Where residential sprinklers are used outside the dwelling unit as allowed by 6.2.2.2, the W:� Ji _W discharge criteria shall be in accordance with Section 7.1, except as modified by 7.2.4.1, u. in III a 7.2.4.1 Residential sprinklers shall be permitted to be used In ordinary hazard areas U) 0. 91 10 1 11.1 that meet the following conditions: (4 {O (1) The area Is compartmented Into 500 ft2 or less by 30-mJnute fire -rated construction. (A(2) The sprinklers are spaced at 130 11:2 per sprinkleri'F. (3) Openings have a lintel at least 8 In. in depth. co (4)Thetotal area ofopenings, excluding any overhead garagedoors thatopen to the exterior F does not exceed 50 ft- for each compartment. (5) Discharge densities are In accordance with NFPA 13 for ordinary hazard. Z 7.2.5 The number of design sprinklers for a corridor or breezeway outside the dwelling unit sihall U LU Include up to the four most hydraulically demanding adjacent sprinklers. LY SPARE HEAD CABINET CONTENTS: CITY APPROVAL STAMP: E (6) 1Y2234 Tyco LFII 155°F Pendent (1) W-Type 7 Sprinkler Wrench lin, 1Pnn11,r sy,,,, Sh be Pra-t.stod end a,tarad r10 Tagr[a F ire Reporting ytem Pon, w Ina, N. www.Tegr co 0. A LIST OF APPROVED PRODUCTS FOR USE WITH BLAZEMASTER CPVC W < A COMPLETE AND UP-TO-DATE PRODUCT SEARCH, PLEASE GO ONLINE TO PIPE IS INCLUDED WITH THE PRODUCT SPECIFICATIONS BOOKLET. FOR XPPR - <hnp://www.lubrizol.com/CPVC/ChemicalCompatibilityFinder.html> 1// All Z RECEIVED IIn n C%E�, L I - MAR 13 2020 >- L9 0 M1 III MIKI.^ 7P J {. 1 2. 3 Residential pendants 7.ti 23 non -dwelling areas per 7.2:3:1 --j'-__--'_----�1 � � ��=`-4------ � i--------------_ OF I (i - - 1 RISER SPRINKLER RISER STOR'./MECH. I "- uP UP I -' - I STOR.IMECH. j STOR /MECH. 1 409- OFFICE OFFICE BATH BATH BATH o 1fll 505 I V1i/Q ..,.,.) ...,... W/D '7 4� - kf L 5 I� W/D _ I REF _I<? .._....:. ,..- REF:...I .nn -. -. .. .� �. CLO;.,,, - 1-2: 1 x 9'- 2:,Tx,9'- -- iDV'y DiV'_ Rises-� � �50 ;Roo 01 - - UNITS. � I I f . UNIT4 .. .... . BEDROOM TYPE B: TYPE A' 503.. LIVING ROOM LIVING ROOM �501 4Q1:. 4.1 2' A4.�.' _ A3jf BLDG 1 - 1ST FLOOR iw._W SCALE: 1 4" = 1' - O" Hydraulic Information: OCCUPANCY CLASSIFICATION Ordinary Grodo,,Il DENSITY (gpm/1`11:2) 0.15 for 900ft2 (Actual 73ft2) J TOTAL HEADS FLOWING' 1 K-FACTOR 4.9' TOTAL WATER REQUIRED 19.50 TOTAL PRESSURE REQUIRED 38.449 BASE of RISER (gpm) 19.50 BASE of RISER si) _ 38.449 ..... SAFETY MARGIN (psi) 1 +24.540 39.0%) . _, .... Kesment:al-neau CalcuraLea per7.i ae /as4.l SO 1%2 No AS (6.6.7) 14 k OS sal 404 CLOSET C04 1 x 9'-2 Rise 1- : BEDROOM BEDROOM 403 '. 303. - UNIT3 - - TYPES n OFFICE OFFICE 307 207 KITCHEN 'I KITE21 i I I UNIT 2 TYPE B LIVING ROOM 301 I ;1 ELECT. SERVICE s I; 204 O BEDROOM 203 '- I UP a CLOSET i AVFAIFA %I r. BEDROOM n - r:iia- i � Iillllll�_ BEDROOM 103 {-8) jIJ z 1j C- U_ Z LL 0 UNIT 1 rl TYPEA 0,0 - LIVING ROOM 101.1 ._- No AS (6.6.Z) ' rl 1 0 T � � l re> CODE QUICK REFERENCES.. System supply is coming from a new s"'wbtdr inaip extension 0,tliin.new hunrant located on S(W.2" poly run5:hpprox. lUfr6in NYLAN D APARTMENTS a " rox.116'toa Z" male U) 6.6 LOCATION OF SPRINKLERS: tee to a new 2" DCDA located in vault standard detail WA-141. 2" poly underground continues pp r , . 6.6.1 Sprinklers shall be installed in all areas except where omission Is permitted by 6.6.2 through 6.6.7. threaded adapter left by others in the fire sprinkler riser room In Building 2 and approx. 142' to Building 1. 4" Storz FDC to be 6.6.2* Sprinklers shall not be required In bathrooms where the bathroom area does not exceed 55 ft=. Iccated in parking lot per Civil Plan C4.1. All underground, Including FDC, by others. Moore Fire's scope of work to begin at 2" SITE SPECIFICATIONS 13 R 6.6.3 Except where specified in 6.6.4, sprinklers shall not be required In clothes closets, linen closets, and pantries within male threaded adapter left by others. - Edmonds Fire Marshal Owner/Lessee: ... Roy Gursll, 426 210-5502 Aelate .................... Y ( ) dwelling units that meet all of the following conditions: (1) The area of the space does not exceed 24 ft2. (2) The walls and GENERAL NOTES AND LIABILITY: Related Permit No: ...BLD20190998 5909 - 164th St. SW ul N � m # a ceilings surfaced with noncombustible or limited -combustible materials as defined by NFPA 220. U) O co x Z 6.6. Sprinklers shall be installed in any closet used for heating or air-conditioning equipment, washers, dryers, or water Al system piping is to be supported per manufacturer's specifications and is to be secured to prevent lateral movement. Pipe Occupancy Type:......R-2 Lynnwood, WA 98037 O J ko heaters. except as permitted by 6.6.7. Is to be secured to prevent sprinkler head movement. Type: ,,, y prinklered Parcel No:...........00463303200303 �, O: Moore Fire Protection's warranty of work does not cover any damage due to freeze related problems. Wet piping shall be Construction T V-B Full S . a S.6.5• Except as provided for in 6.6.5.1, sprinklers shall not be required in any porches, balconies, corridors, carports, ports No. Of Stories: .. ....... 2 Legal Description: d ui cocheres, and stairs that are open and attached. protected against only with o Ins below 40 degrees Fahrenheit. Insulation installed for this purpose shall be located er the cold General Description: Two new apartment HANBURYS SOUND VIEW TRS BLK 032 D-03 - N t2 N ° vu_1 side of the pipe only with no Insulation on the warm side of the pipe facing the heated Interior. Coordinate with general and/or v 1A U T 6.6.6.*,Sprinklers shall not be required In o attics, penthouse equipment rooms, elevator machine rooms, concealed , elevator buildings with 19 units 145FT OF W 30FT OF LOT 3 ALSO N 145FT OF E d „ y O Insulation contractor. All Insulation to be by others. dedicated exclusively to and containing only dwelling unit ventilation equipment, crawl spaces, floor/telling spaces, elevator total. Building 1 is 70FT OF LOT 4ALSO N 120FT OF LOT 4 EXC E m i o d O Moore Fire Protection shall not be responsible for the ability of the structure to adequately support the fire sprinkler system or � w m shafts where the elevator Installation compiles with ANSI a and safety code for elevators and escalators, and other concealed 7,813 W with two 70FT ALSO N 120FT OF E 1/2 OF LOT 5 EXC S O d a " r`'r t - f .spaces :that are not Intended for lire p g equipment. any appurtenances thereof. g purposes or storage and do not contain fuel -fired a ul ment. Owner is responsible for the periodic inspection, testing and maintenance of the water based fire protection system(s) in stories and Building 2 5FT OF N 145FT OF W 60FT OF E 70FT SDLOT 4 CY * o regardless less olere shall not be required in closets (regardless of size) on exterior balconies and exterior breezeways/corridors, is 9,245 ft2 with three PER BLA 002-94 REC AF NO 9408050454 = 0 accordance with the requirements of NFPA 25. - Q o, o eagaMless of size, as long as the closet does not have doors or unprotected penetrations directly Into the dwelling unit. FIRE FLOW: stories. d N e, o N w 64.9i2* Sprinklers shall not be required underneath stair risers in dwelling units where the walls and ceilings are surfaced with Fire flow model provided by Cody -Lee A. Gray, Olympic View Water & Sewer District 12/6/19 V) m E o w -i noncombustible or limited -combustible finishes. from node F-2456 located at the hydrant on site. With a static pressure of 63 PSI: the 8 in, main O' "-' n m N w A LIST OF APPROVED PRODUCTS FOR USE WITH BLAZEMASTER CPVC d d r^ '7.2 DESIGN CRITERIA -OUTSIDE DWELLING UNIT: extension can provide 1,7D0 GPM with 20 PSI residual pressure. N � u1 Z .-i `-p 7:2.1 Areas outside the dwelling unit shall comply with Section 7.2. PIPE IS INCLUDED WITH THE PRODUCT SPECIFICATIONS BOOKLET. FOR 1.2.2 The. number of design sprinklers for a corridor or breezeway outside the dwelling unit shall Include up to the four most A COMPLETE AND UP-TO-DATE PRODUCT SEARCH, PLEASE GO ONLINE TO. SYSTEM SPECIFICATIONS hyifraul caliy demanding adjacent sprinklers. <http://www.lubrizol.com/CPVC/ChemicalCompatibilityFinder.html> BUILDING CODE: 2015 IBC with WA State Amendments 1 The design discharge and design area criteria for areas protected by quick -response sprinklers shall comply with NFPA 13 SYSTEM TYPE: 2016 NFPA 13R Wet S ,inkier System-:� excceptaeallowed by 7.2.3.1. a SPRINKLER COVERAGE: Dwelling Compartments with 3 Heads: 16'-0" X 16'-0" 256 ft max/hd. .�y U)...o w a N:'. n w 0imil1 For compartments 500ll b or less that meet all of the following conditions and are protected with quick -response e Dwelling Compartments with 2 Heads or Less: 20'-0" X 20'-0".400 W. sprinklers, the design area shall be permitted to be limited to the number of sprinklers in the compartment but shall not exceed storage, Mechanical, Electrical, Sprinkler Riser: 130 ft2 max. .:per head. Z four sprinklers: a a ap (1) The area is protected with 30 minute -rated construction. SPRINKLER SPACING: Covered Patios: 225 ft max. per pendent, 196 ft max. persidewall. (2) The sprinklers are spaced at 225 ft2 maximum for light hazard, 130 ft2 maximum for ordinary hazard, or in accordance with Residential Pendants: Dry Barrel Pendents: Dry Barrel Sidewalis: O ; ,CD their listing. 16'/ 20' max. between heads. 15'-0" max. between heads. 14'-0' max. between heads. L r (3) Openings have a lintel depth at least 8 In. in depth. 8' / 10' max. from any wall. 7'-6" max. from any wall. T-0' max. from adjacent wall. ' - 3 (4) The total area of openings, excluding any overhead doors that open to the exterior, does not exceed 50 ft2 for each 8'-0" min. between heads. 6'-0' min. between heads. 6'-0" min. between heads. 1 compartment. 4"-12' deflector to telling. L I SPRINKLER DETAILS: ui (5) Discharge densities are in accordance with NFPA 13. 4.9K semi -recessed residential pendants are W c 7.2.4 Where residential sprinklers are used outside the dwelling unit as allowed by 6.2.2.2, the discharge criteria shall be in used throughout Interior. S.6K skirt &sleeve H accordance with Section 7.1, except as modified by 7.2.4.1. standard spray quick response dry barrel CITY APPROVAL STAMP: E 7.2.4.1 Residential sprinklers shall be permitted to be used In ordinary hazard areas that meet the following conditions: pendants are used on first Floor covered O- a/ w (1) The area is compartmented Into 500 ft2 or less by 30-minute fire -rated construction. patios. 5.6K skirt & sleeve standard spray (2) The sprinklers are spaced at 130 ft2 per sprinkler. -- (3) Openings have a lintel at least 81n. In depth. quick response dry barrel sidewalls are used;U on upper floor covered patios. 1't co The total area of openings, excluding any overhead garage doors that open to the exterior, does not exceed 50 ft2 for each compartment. PIPING DETAILS: (5) Discharge densities are in accordance with NFPA 13 for ordinary hazard. All aboveground piping denoted with only W 7.2.5 The number of design sprinklers for a corridor or breezeway outside the dwelling unit shall Include up to the four most the pipe diameter to be CPVC plastic with hydraulically demanding adjacent sprinklers. CPVC fittings except as noted on the riser N detail. f HAZARD CLASSIFICATION: �'- ` Dwellings: Residential at 0.05 density. RECEIVED Storage, Mechanical, Electrical, Sprinkler a Riser: Ordinary Hazard Group I at 0.15 MAR 13 2020 c! Covdenered Patios: Light Hazard at 0.1 density. BUILDING z m ---_- -. i COVERED ENTRY ON -------- i---ix0• i +h-DN W/D 0 3 3® 12 BEDROOM BEDROOM -t0O13 9OB. )SET CLOSET CLOSET CLOSET -COVEREDENTRY - WJD COVERED ENTRY ON ENEW19011M 1 (6.6.7) No AS (6.6.7) _____-_ DECK ON L COVERED ENTRY - _.. - -r 12 1x0'-1 3®- + -D 1x0' '•DN i 3 3® 12 BEDROOM 12 I _ 14 rr� 12, 12 �6 BEDROOM >, IS I _ 6D6: EA1 H a W/o 1, 705 6 C CLOSET CLOSET CLOSET CLOSET �704 ( 604 F GILOSET CLOSET 808 807 __ 707 l 708J -- - - �) E 6� b- z CL LL LL G � M E J - _ 1606J 07 I I e I ( 0 I w 10 ft2 No lO ft2 No I I' I h I yv . aDt�' 10 ft2 No to ft2 No I N wH wHl I wH}I f30 ft2+NoAS (6.6.3) AS (6.6.3) v, I 1: I. - J AS (6.6.3) A5 (6:6.3) lL _� WHc is > I l ( _ AS (6.6c3jooC 1. ( r . 14 _ , -:.': - .....--.{- .:. R 91.g-'U .- : F.ElfL3'-3_UP _ _ " + .X 3.,,- X 3. 5V2.UP. 3...3.,, IIp. ,. a �. 1ae12s1 9.2 X .Sh UP Iiiae=1-2:..1x93. :: :.:. ... + _ .. _31C3=3'1x''- v - ._ (.l. �, v is r _. - - 1 x 3 -5+h -Up - Rise i- : S s- . r . Ise 1-2: 1 9 -2 1 x 3 -S+fi -UP':, 1:X.3 5 h UP. _. �tIP I. I I i-2. 1 x 9- Rise 2. 1 x 9 I:.-,a� Rise 1-Z.1 x 9 x 9 2 _ ,., - .' Ride 1 2 1 x 9- w w _- I I .....-_ 3 3 w- -._ 1 I Rise 1 2: ixs' _ KITCHEN ls_ I_ j KITCHEN { KITCHEN I. I KITCHEN 3 3 " t I 12 12 12 12 7 IKTTCHEN I E o 0 t �Q2: D r� -- 1 • • ll 111, I BEDROOM 1-:_ I; BEDROOM BEDROOM N _ k` j BEDROOM BEDROOM I �1003� 903 1 I..-803 703' 603 D I 3 i IC� e -- -„ t- "I 1 f _- i I -1- ) I « I L: I id8iitial!0.059PM1R3,fds' a a t UNIT10' ® 3; 3` :jy_:V I'f`9 UNITE , 3 3 [� UNIT? UNITg I 1. o+ r 12 12'. 12 12: .-....... _: ..._.. .._: ...............:- 12. 313.:_ ---- _ i w5= ;iL1VING ROOM '----'-.. ..: -----LIVING::ROOM :... ............... _ LIYING.ROOM �LI(! N QOM - _ _ L_--t _.� __ _: _ 1001 9.01 801 ZD1 GR OM F 5 ;_._._ __ T. T.__• . -� - LN� IR �.. m a 15 Residential•0.0591111in/ft° for 301ftz j I I I j PIP I---- --------- -- -- -- _.------- _ - (I I a I I N BLDG .1 � 2ND FLOOR CODE QUICK REFERENCES: SUPPLY. r System supply is coming from n anew 8" water main extension to the;new'hyd .. located on site. 2:" poly runs,approx. LO' from �I YLAN D APARTMENTS 1G'-D':. -NFPA SCALE: 1 4" 1' �" v� S,6 LOCATIOW OF"SPRINKLERS: tee to a naw 2" DCDA located (n vault per standard detail WA-141. 2" poly undergrounH continues approx. Yi6`to a 2" Pnale 6.6:.1. Sprinklers shall be installed in all areas except where omission is permitted by 6.6.2 through 6.6.7. threaded adapter left by others In the Flre sprinkler riser room In Building 2 and approx. 142' to Building 1.4" Storz FDC to be ` ' • • : to 6:6.2* Sprinklers shall not be required In bathrooms where the bathroom area does not exceed 55 ft2. located In parking lot per Civil Plan C4.1. All underground, Including FDC, by others. Moore fire's scope of work to begin at 2" SITE SPECIFICATIONS 13 R 6.6.3 Except where specified In 6.6.4, sprinklers shall not be required in clothes closets, linen closets, and pantries within male threaded adapter left by others. dwelling units that meet all of the following conditions: (1) The area of the space does not exceed 24 ft2. (2) The walls and GENERAL NOTES AND LIABILITY• AH3:........................ Edmonds Fire Marshal Owner/Lessee:... Roy Gursh (421) 1111-5502 ceilings are surfaced with noncombustible or limited -combustible materials as defined by NFPA 220. Related Permit No:... BLD20190998 5909 - 164th St. SW- to N '�° +o a :6:5;4" Sprinklers shall be installed In any closet used for heating or air-conditioning equipment, washers, dryers, or water Is system curing is r e supported per manufacturer's specifications and is to be secured to prevent lateral movement. Pipe Occupancy Type:...... R-2 In O m ni Is to be secured to prevent sprinkler head movement. Lynnwood, WA 98037 X ci z heaters except as permitted by 6.6.7. Moore Fire Protection's warranty of work does not cover any damage due to freeze related problems. Wet piping shall be Construction Type. Fully Sprinklered Parcel No:...........00463303200303 0 Obi v N to coche Except as provided for In n and1, sprinklers shall not be required in any porches, balconies, corridors, carports, Porte protected against temperatures below 40 degrees Fahrenheit. Insulation installed for this purpose shall be located on the cold No. Of Stories:......... 2 Legal Description: cocheres,.and stairs that are open and attached. P P++ 6.6.6* Sprinklers shall not be required in attics, penthouse equipment rooms, elevator machine rooms, concealed spaces side of the pipe only with no Insulation on the warm side of the pipe facing the heated Interior. Coordinate with general and/or General Description: Two new apartment HANBURYS SOUND VIEW TRS BILK 032 D-03 - N ~ Q N N o .-:...: ::: - insulation contractor. All Insulation to be by others bullding s with 19 units 'r ut V Hydraulic' Information OCCUPANCY' CLASSIFICATION Residential DENSITY (gpm/ft2) 0.05 for 768ft=''(AetuaIl301ft2) TOTAL HEADS: FLOWING 3 K-FACTOR 4.9 TOTAL WATER REQUIRED 40,24. TOTAL PRESSURE REQUIRED 46.999 BASE of RISER (gpm) 40.24 .. BASE of RISER (psi) 46.999 SAFETY' MARGIN (psi) +15.959 25.3% dedicated exclusively to and containing only dwelling unit ventilation equipment, crawl spaces, floor/ceiling spaces, elevator 145FT OF W 30FT OF LOT 3 ALSO N 145FT OF E shafts where the elevator installation compiles with ANSI A17.1, safety code for elevators and escalators, and other concealed Moore Fire Protection shall not be responsible for the ability of the structure to adequately support the fire sprinkler system or .total. Building 1 is 70FT OF LOT 4ALSO N 120FT OF LOT 4 EXC E spaces,that are not Intended for living purposes or storage and do not contain fuel -fired equipment. any appurtenances thereof. 7,813 ft2 with two 70FT ALSO N 120FT OF E 1/2 OF LOT 5 EXC S 6.6,7'Sprinklers shall not be required in closets (regardless of size) on exterior balconies and exterior breezeways/corridors, Caner Is responsible for the periodic inspection, testing and maintenance of the water based fire protection system(s) in stories and Building 2 SFT OF N 145FT OF W 60FT OF E 70FT SD LOT 4 regardless of size, as long as the closet does not have doors or unprotected penetrations directly Into the dwelling unit. accordance with the requirements of NFPA 25. is 9,245 ft2 with three PER BLA 002-94 REC AF NO 9408050454 6.6.9.2* Sprinklers shall not be required underneath stair risers In dwelling units where the walls and ceilings are surfaced with FIRE FLOW: stories. Fire fo I m -r 'y E O Q 3 = E i (Y * a Q N $ m o N y 2 O 01 ,,10., O (in U) � noncombustible or ERIA-OUTSItlble finishes. Flow model provided by Cody -Lee A. Gray, Olympic View Water &Sewer District 12{6/19 7 U) 1B E mo w � A LIST OF APPROVED PRODUCTS FOR USE WITH BLAZEMASTER CPVC from node F-2456 located at the hydrant on site. With a static pressure of 63 PSI, the 8 in. main 7.2 DESIGN CRITERIA - OUTSIDE DWELLING UNIT: extension Cy" da m [4 F N O iWu can provide 1,700 GPM with 20 PSI residual pressure. 7.2.1 Areas outside the dwelling unit shall comply with Section 7.2. PIPE IS INCLUDED WITH THE PRODUCT SPECIFICATIONS BOOKLET. FOR P p The number Q ry m N •t: O z 7.2.2 of design sprinklers for a corridor or breezeway outside the dwelling unit shall include up to the four most A COMPLETE AND UP-TO-DATE PRODUCT SEARCH, PLEASE GO ONLINE TO SYSTEM SPECIFICATIONS Rif '4 m U) hydraulically demanding adjacent sprinklers. <http://www.lubrizol.com/CPVC/ChemicalCompatibilityFinder.html> d E U.1 7.2.3-The design discharge and design area criteria for areas protected by quick -response sprinklers shall comply with NFPA 13 BUILDING CODE: 2015 IBC with WA State Amendments except as: allowed b 7.2.3.1. ~ iu •• .. P Y SYSTEM TYPE: 2016 NFPA S3R Wet S ,inkr 5 stem : 7.2,3.1 For compartments 500 ft2 or less that meet all of the following conditions and are protected with quick response SPRINKLER COVERAGE: Dwellings: 16'-0" X 16'-0" ie256 ftz maximum head. -- ZD io n per sprinklers; the design area shall be permitted to be limited to the number of sprinklers In the compartment but shall not exceed p : Storage, Mechanical, Electrical, Sprinkler Riser: 130 ft2 max per head - kl '4 (A..O.ur 0. U) 0w urspr n am:Largest compartment contains only (3).heads. (1} Tharea Is protected with 30 minute -rated construction. Covered Patios: 225 ft2 max, per pendent,196 ft2 max. ersidewalconstruction. Hydraulic Information OCCUPANCY CLASSIFICATION ' Residential DENSITY (gpm/ft2) 0.05 for 400ft2' Actual 128ft2 TOTAL HEADS FLOWING 1 K-FACTOR 4.9 TOTAL WATER REQUIRED 20.00- TOTAL PRESSURE REQUIRED 46.065 BASE Of RISER (gpm) 20.00 BASE of RISER (psi) 146.065 SAFETY MARGIN (psi) +16,923 (26.9%) (2) The sprinklers are spaced at 225 ft2 maximum for light hazard, 130 ft2 maximum for ordinary hazard, or In accordance with their listing. SPRINKLER SPACING: Residential Pendants: D Barrel Pendants: �' Dry D Barrel Sidewalls: Ln �. o o (3).Openings (4) have a lintel depth at least 8 In. In depth. The total area of openings, excluding any overhead doors that open to the exterior, does not exceed 50 11:2 for each 16'-0" max. between heads, LS'-0" max. between heads. 8'-0" max. from any wail. 7'-6" max. from any wall. 6'-0" min. from heads. 6'-0" between 14'-0" max. between heads.. T-0" max. from adjacent wall. : �L, L of r - compartment. - (5) Discharge densities are in accordance with NFPA 13. min. heads. SPRINKLER DETAILS: 6'-0" min. between heads. 4"-12" deflector to ceiling. r- i 7.2.4 Where residential sprinklers are used outside the dwelling unit as allowed by 6.2.2.2, the discharge criteria shall be in accordance with Section 7.1, except as modified by 7.2.4.1. 4.9K semi -recessed residential pendants are used throughout interior. 5.6K W C v '7.2.4.1 Residential sprinklers shall be permitted to be used In ordinary hazard areas that meet the following conditions: skirt & sleeve standard spray quick response dry barrel CITY APPROVAL STAMP: G p ` E E (1), The area Is compartmented into 500 ft2 or less by 30-minute fire -rated construction, (2) The sprinklers are spaced at 130 ft2 sprinkler. pendants are used on first Floor covered 5.6K & O =,, W per (3) Openings have a lintel at least 8 in. In depth. (4) The total area of openings, excluding any overhead doors that to the does patios. skirt sleeve standard spray quick response dry barrel sidewalls are used floor �. (Z ; ut garage open exterior, not exceed 50 ft2 for each compartment. on upper covered patios. 0- ,;_ . (5) Discharge densitles are in accordance with NFPA 13 for ordinary hazard. PIPING DETAILS: All aboveground piping denoted with only N � in number ol design sprinklers for a corridor or breezeway outside the dwelling unit shall Include up to the four most the pipe diameter to be CPVC plastic with hydraulically demanding adjacent sprinklers. W y,- CPVC fittings except as noted on the riser detail HAZARD CLASSIFICATION: Dwellings: Residential at 0.05 density. Storage, Mechanical, Electrical, Sprinkler - RECEIVED LL._ Z c. Ln Riser: Ordinary Hazard Group I at 0.15 - - density. MAR 13 2020 �(7 Covered Patios: Light Hazard at 0.1 density. BUILDING ? m MATCH LINEl' MONO SCISOR TRU _. -. SLOPED ROOF - __--...-..___--. SLOPED ROOF CONSTRUCTION R39 % R-49 i� L ONST r1 _J2 �.,g, ,1 -SEt7PEB�R00 GOti51tRIBA a''W ATEDFYWOOD R-49 . ' --- T R GWB OVER ROOF RAMI G Ll - GWB OVER ROOF FRAMI 1�-T.0.4AFF GWB OVER ROOF FR UNG. GWS OVERROOFIIN GWB .OVER ROC INTERIOR PARTITION WITH SOUND INSUL. - 1 HOUR WALL CONSY... 1 HOUR WALL CONST. BEDROOM KITCHEN KITCHEN BEDROOM' BEDROOM - GWS OVER VAPOR. BARRIER,.TY .; ,, 11MRIOR PARTITION'WITH SOU I9UL%- 1. HOUR WALL CONST. FLOOR CONST. WITH SO ,.SUS; FLOORC �11D FLR. ".X10WOODTRIM (2)LAYERS 1/2"TYPEX ON RESILIENT CH LS FOR HR RATING (2)LAYERS 112"TYPE B O RESILIENT CHANNELS FOR I HR G BEDROOM ALL CONST R-21� ! KITCHEN KITCHEN BEDROOM BEDROOM \y' INTERIOR PARTITION WITH SOUND INSUL. 1 HOUR WALL CONST. INTERIOR PARTITION WITH SOU SU . 1 HOUR WALL CONST. — 4" CONC. SLAB PER STUR JT� ///�-� R-10 RIGID UNDER SLAB INSUL. FOUNDATION D AII*OUNDATION BLDG 1 - SECTION 1/A4.2 SCALE: 1/4" = 1' — 0" R-10 RIGID UNDER SLAB INSUL. oz ,RATED FIR P ATED P YWDOD Ur t , MONO SCISISOR TR .I :. CSLOPED ONSTRROOF -.___ _— v SLOPED ROOF RIOGEVENT CONSTRUCTION 4 r� vf: 1 - SyT- a R4�g9 1HOUR A pNS2 B SLOPEDROOFnn CONSTRUOTIO-td4RATE. R49 FIRE.RATEOP P -000' R19 .. e VENTED BL CKING GWB OVER ROOF RAM J J11- GWB OVER FRAMI � 1g�}-1" 1� T.O. R AFF T. R INTERIOR PARTITION WITH SOUND INSUL GWS'OVER ROOF 1'HOUR WALL CONST. �SF GWB OVER ROOF FRAMING IN GWB OVER ROOF FRA I G EXTER OR S�FI I HOUR WALL CONST. METALGUTTER R WO( KITCHEN KITCHEN. BEDROOM BEDROOM KITCHEN ;INTERIOR PARTITION WITH SOU 11 SUIL. INTERIOR PARTITION WITH SOU qD INSUL. - 1 HOUR WALL CONST. GWB OVER VAPOR 8 IER, T) ISUL:, /- FLOOR CONST. WI l I UND INSUL: —\ (2) LAYERS 1l2"TYPE X/CB ON RESILIENT CH J LS FOR i HR RATING (2) LAYERS 172"TYPE KITCHEN KITCHEN INTERIOR PARTITION WITH SOUND INSUL, I HOUR WALL CONST. ! — 4" CONC. SLAB PER STURQ R-10 RIGID UNDER SLAB INSUL LA ?SILIENT CHANNELS FOR 1 HIR (2) LAYERS 1/2"TYPEX WS ON RES LIENT CH �Fi G 2 d BEDROOM BEDROOM KITCHEN i HOUR WALL CONST. INTERIOR PARTITION WITH SOU I INTERIOR PARTITIOISV�WOU P� 4" CONC. SLAB PE RC7. 101 —COI R-10 RIGID UNDER SLAB INSUL. R-10 RIGID UNDER SLAB INSUL FOUNDATIONS - •� N In a d u J SUPPLY: CODE QUICK REFERENCES NYLAND APARTMENTS System supply is coming from new o" water main extension to the new hydrant located site. 2" poly runs approx. 10' from 6.6 LOCATION OF SPRINKLERS: tee to a new 2" DCDA located inn vault per standard detail WA-141. 2" poly underground continues approx. 116' to a 2" male 6.6.1 Sprinklers shall be installed in all areas except where omission is permitted by 6.6.2 through 6.6.7. threaded adapter left by others In the fire sprinkler riser room in Building 2 and approx. 142' to Building 1. 4" Storz FDC to be 6.6.2* Sprinklers shall not be required In bathrooms where the bathroom area does not exceed 55 ft2. located In parking lot per Civil Plan C4.1. All underground, Including FDC, by others. Moore Fire's scope of work to begin at 2" SITE SPECIFICATIONS 13 R 6.6.3 Except where specified in 6.6.4, sprinklers shall not be required in clothes closets, linen closets, and pantries within male threaded adapter left by others, dwellingunits that meet all of the following conditions: 1 The area of the space does not exceed 24 ft2. 2 The walls and AN]: Edmonds Fire Marshal Owner/Lessee:... Roy Gursli, (425) 210-5502 9 O P O GENERAL NOTES AND LIABILITY: n m ceilings are surfaced with noncombustible or limited -combustible materials as defined by NFPA 220. Related Permit :..... BLD20190998 5909 - 164th St. SW (A N 1O m a 6.6.4* Sprinklers shall be installed in any closet used for heating or air-conditioning equipment, washers, dryers, or water All system piping is to ve supported per manufacturer's specifications and is to be secured to prevent lateral movement.. Pipe Occupancy type:...... R-2 L nnwood, WA 98037 °' x u Z heaters exce t as permitted by 6.6.7. is to be secured to prevent sprinkler head movement. Y P P Construction Type:...V-B Fully Sprinklered Parcel No• ...........00463303200303 On m N -1 6.6.5* Exce t as provided for In 6.6.5.1, sprinklers shall not be required in an porches, balconies, corridors, carports, orte prole Fire Protection's warranty of work does not cover any damage due in freeze related problems. Wet piping shall be 01 , ,y P p p q y p p P protected against. temperatures below 40 degrees Fahrenheit. Insulation installed for this purpose shall be located on the cold No. Of Stories:......... 2 .Legal Description: j a cocheres, and stairs that are open and attached. side of the pipe only with no insulation on the warm side of the pipe facing the heated interior. Coordinate with general and/or General Description: Two new apartment HANBURYS SOUND VIEW TRS BLK 032 D-03 - N d ' N o w 6.6.6* Sprinklers shall not be required in attics, penthouse equipment rooms, elevator machine rooms, concealed spaces insulation contractor. All insulation to be by others. buildings with 19 units 145FT OF 30FT OF LOT 3 ALSO -N 145FT OF E in V Lu dedicated exclusively to and containing only dwelling unit ventilation equipment, crawl spaces, floor/ceiling spaces, elevator - Q w p shafts where the elevator installation complies with ANSI A17.1, safety code for elevators and escalators, and other concealed Moore Fire Protection shall not be responsible for the ability of the structure to adequately support the fire sprinkler system or total. Bilding 1 is 70FT OF LOP 4AL50 N 120F2 OF LOT 4 EXC E CO = E w O any appurtenances thereof. stole ft2with two 70FT ALSO N 120FT OF E i/2 OF LOT 5 EXC S O Q m 01 10 spaces that are not intended for living purposes or storage and size) not contain fuel -fired equipment. Owner is responsible for the periodic inspection, testing and maintenance of the water based fire protection system(s) in stories and Building 2 5FT OF N 02-94 OF W SOFT OF E 07oFr504 4 LOT 4 = C * F to 6.6.7 Sprinklers shall not be required in closets (regardless of size) on exterior balconies and exterior breezeways/corridors, accordance with the requirements of NFPA 26. is 9,245 ft2 with three PER BLA 002-94 REC AF NO 9408060454 ' d � o regardless of size, as long as the closet does not have doors or unprotected penetrations directly Into the dwelling unit. S w F o 6.6.9.2* Sprinklers shall not be required underneath stair risers In dwelling units where the walls and ceilings are surfaced with FIRE FLOW: stories. Q ,car, o N LU noncombustible or limited -combustible finishes. Fire flow model provided 6y Cody -Lee A. Gray, Olympic View Water & Sewer District 12/6/19 N '^ E o w A LIST OF APPROVED PRODUCTS FOR USE WITH BLAZEMASTER CPVC from node F2456 located at the hydrant on site. With a static pressure of 63 PSI, the 8 in. main '" n 3 m o n�i w 7.2 DESIGN CRITERIA -OUTSIDE DWELLING UNIT: extension can provide 1,700 GPM with 20 PSI residual pressure, d H m r J i- 7.2.1 Areas outside the dwelling unit shall comply with section 7.2. PIPE IS INCLUDED WITH THE PRODUCT SPECIFICATIONS BOOKLET. FOR N O °o Z ry to to 7.2.2 The number of design sprinklers for a corridor or breezeway outside the dwelling unit shall include up to the four most A COMPLETE AND UP-TO-DATE PRODUCT SEARCH, PLEASE GO ONLINE TO SYSTEM SPECIFICATIONS 4 E a ¢ ti � hydraulically demanding adjacent sprinklers. <http://WWW.lubrizol.com/CPVC/ChemicalCompatibilityFinder.html> - _4 Lu' .. 7.2.3 The design discharge and design area criteria for areas protected by quick -response sprinklers shall comply with NFPA 13 BUILDING CODE: 2015 IBC with WA State Amendments p cwi :j �... d except as allowed by 7.2.3.1. SYSTEM TYPE: 2016 NFPA 13R Wet Sprinkler System 7.2.3.1 For compartments 500 ft2 or less that meet all of the following conditions and are protected with quick -response SPRINKLER COVERAGE: Dwellings: IV-0" X 16'-0" 256 ft2 maximum per head. N. .w a in w sprinklers, the design area shall be permitted to be limited to the number of sprinklers in the compartment but shall not exceed Storage, Mechanical, Electrical, Sprinkler Riser: 130 ft2 max. per. head. four sprinklers. Covered Patios: 225 ft2 max. per pendent, 196 ft2 max. per sidewall. L (1) The area is protected with 30 minute -rated construction. SPRINKLER SPACING: Ln ko (2) The sprinklers are spaced at 225 ft2 maximum for light hazard, 130 ft2 maximum for ordinary hazard, or In accordance with Residential Pendants: Dry Barrel Pendants: Dry Barrel Sidewalls: O v • O their listing. 16'-0" max. between heads. 15'-0" max. between heads. 14'-0" max. between heads.00 (3) Openings have a lintel depth at least 8 In. in depth. (4) The total area of openings, excluding any overhead doors that open to the exterior, does not exceed 50 ft2 for each 8'-0" max. from any wall. T-6" max. from any wall. T-0" max. from adjacent b!ds: all. L Z 3 8'-0" min. between heads. 6'-0" min. between heads. 6'-0" min. between heads. f-• compartment. 4"-12" deflector to ceilm U W (5) Discharge densities are in accordance with NFPA 13. -SPRINKLER DETAILS: 9• vi 7.2.4 Where residential sprinklers are used outside the dwelling unit as allowed by 6.2.2.2, the discharge criteria shall be in 4.9K semi -recessed residential pendents are W c accordance with Section 7.1, except as modified by 7.2.4.1. used throughout interior. 5.6K skirt & sleeve o 7.2.4.1 Residential sprinklers shall be permitted to be used in ordinary hazard areas that meet the following conditions: standard spray quick response dry barrel CITY APPROVAL STAMP: E (1) The area Is compartmented Into 500 ft2 or less by 30-minute fire -rated construction. pendants are used on first floor covered � �/ W (2) The sprinklers are spaced at 130 ft2 per sprinkler. patios. 5.6K skirt & sleeve standard spray 0 'C2 (3) Openings have a lintel at least 8 in. in depth. quick response dry barrel sidewalis are used ry �. (4) The total area of openings, excluding any overhead garage doors that open to the exterior, does not exceed 50 ft2 for each - - on upper floor covered patios. L�L1 a compartment. PIPING DETAILS: LL (5) Discharge densities are in accordance with NFPA 13 for ordinary hazard. All aboveground piping denoted with only Q t 7.2.5 The number of design sprinklers for a corridor or breezeway outside the dwelling unit shall Include up to the four most the pipe diameter to be CPVC plastic with M v; hydraulically demanding adjacent sprinklers. LL`: Q st CPVC fittings except as noted on the riser detail, HAZARD CLASSIFICATION: ® 0, Dwellings: Residential at 0.05 density, RECEIVE® Ln Storage, Mechanical, Electrical, Sprinkler density.Ordinary Hazard Group I at 0.15 MAR 13 2020 Covered Patios: Light Hazard at 0.1 density. BUILDING 7� a. Ca