BLD2019-0046Type: RESIDENTIAL BLDG
Subtype: ADDITION
Status: ISSUED
Parcel No: 00602600002000 Site
Address: 8802 217TH ST SW EDMONDS,WA 98026-7850
Applied: 1/15/2019
Subdivision: 006026
Lot:
Issued: 1/21/2020 NED
Fire Sprinklers: No Lot
Area: 9583.2 Zoning: RS-8
Final:
Valuation: $60,000.00 Occupancy Type: SFR IRC Construction Type: VB
Expiration Date: 1
P/<202 1
NED
Code Edition: 2015 No. Stories: I # of Dwelling Units: I
WORK DESCRIPTION: INTERIOR REMODEL, CONVERT EXISTING ATTACHED GARAGE TO LIVING SPACE, REMODEL EXISTING
KITCHEN AND BATH.100 SQ FT SINGLE
STORY CONDITIONED ADDITION. 519 SQ FT ATTACHED GARAGE ADDITION.
CONTACTS
NAME TYPE NAME
ADDRESS PHONE
EMAIL
APPLICANT
H21) ARCHITECTS
23020 EDMONDS WAY #12,
(206)542-3734
LISAK@H2DARCHITECTS.COM
EDMONDS WA 98020
CONTRACTOR
TBD
OWNER
REDWOOD LLC
I
8802 217TH ST SW,
�
)235-0283
P�� IM
THEWHITEHEADPACK@GMAIL.C:O
—
EDMONDSWA98026
Contractor License Information:
WA State Contractor L &1 #:EXPRECC066LP City of Edmonds Business License#: 602454996-001-
0001
FEE INFORMATION
DESCRIPTION
ACCOUNT AMOUNT PAID
PAID DATE RECEIPT #
1 - BASE FEE FOR MECHANICAL
PERMITS
001.000.322.10.000.00
$40.00
$0.00
1 - BASE FEE FOR PLUMBING
PERMITS
001.000.322.10.000.00
$40.00
$0.00
B-BUILDING PLAN REVIEW FEE
001.000.345.83.000.00
$612.00
$612.00
1/15/19
REC075275
B-STATE BUILDING CODE
SURCHARGE
001.000.237.ISO
$6.50
BUILDING PERMIT FEE
001.000.322.10.000.00
$820.00
$0.00
CREDIT CARD TRANSACTION FEE
001.000.341.43.100.00
$35.93
$0.00
EACH PLUMBING FIXTURE ON
ONETRAP
001.000.322.10.000.00
$36.00
$0.00
ENGINEERING INSPECTION FEE
001.000.341.82.000.00
$200.00
FAN CONNECTED TO SINGLE
DUCT
001.000.322.10.000.00
$20.00
$0.00
X-TECHNOLOGY FEE
001.000.321.99.100.00
$35.00
TOTALS: $1,84S.43 $612.00
CONDITIONS
�'CbNbiiidlsl TYPE'
F
STATUS NOTES
Printed: Tuesday, January 21, 2020 2:29:33 PM I of 3
RESIDENTIAL BLDG Permit
City of Edmonds PERMIT NUMB
121 Sth Ave N, Edmonds WA 98020 BLD2019 -0046
www.edmondswa.gov / 425.771.0220
Damage to Frontage
Applicant shall repair/replace all damage to utilities or frontage improvements in
Improvments
City right-of-way per City standards that is caused by or occurs during the
permitted project.
ESC Required
Maintain erosion & sedimentation control per city standards.
Applicant, on behalf of his or her spouse, heirs, assigns, and successors in
interests, agrees to indemnify defend and hold harmless the City of Edmonds,
Washington, its officials, employees, and agents from any and all claims for
Hold Harmless
damages of whatever nature, arising directly or indirectly from the issuance for
this permit. issuance of this permit shall not be deemed to modify, waive or
reduce any requirements of any City ordinance nor limit in any way the City's
ability to enforce any ordinance provision.
Inspections
Call for required inspections as noted and prior to backfill.
Final approval on a project or final occupancy approval must be granted by the
Occupancy
Building Official prior to use or occupancy of the building or structure. Check the
job card for all required City inspections including final project approval and final
occupancy inspections.
Any request for alternate design, modification, variance or other administrative
deviation (hereinafter "variance") from adopted codes, ordinances or policies
must bespecifically requested in writing and be called out and identified.
Processing fees for such request shall be established by Council and shall be paid
upon submittal and are non-refundable.
Permit Disclaimer
Approval of any plat or plan containing provisions which do not comply with city
cocleand for which a variance has not been specifically identified, requested and
considered by the appropriate city official in accordance with the appropriate
provision of city code or state law does not approve any items not to code
specification.
Sound/Noise originating from temporary construction sites as a result of
construction activity are exempt from the noise limits of ECC Chapter 5.30 only
Sound/Noise
during the hours of 7:00am to 6:00pm on weekdays and 10:00am and 6:00pm on
Saturdays, excluding Sundays and Federal Holidays. At all other times the noise
originating from construction sites/activities must comply with the noise limits
of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120.
INSPECTIONS
SEQID
INSPECTION TyPE
INSPECTOR
COMPLETED RESULT
NOTES
DATE
FRAMING
PRECON MEETING
DRYWALL FASTENING
ENGINEERING FINAL
FOUNDATION DRAINAGE
ROOF SHEATHING
FOUNDATION WALL
Printed: Tuesday, January 21, 2020 2:29:33 PM 2 of 3
Printed: Tuesday, January 21, 2020 2:29:33 PM 3 of 3
zevi-!'�-ed
ov Et)Afo BUILDING PERMIT
APPLICATION
Development Services
Building Division
121 Sth Ave N / Edmonds, WA 98020
425.771.0220
For handouts, submittal requirements, permit status and inspection
scheduling information go to: www.edmondswa.go .
PLEASE NOTE Intake appointments are required for New Single Family
Residences, Large Additions, ADU's, New Commercial, and Major Tenant
Improvement application submittals. If plans are prepared by a profession-
al, electronic files are requested in addition to the hard copies. Please bring
electronic files on a flash drive or coordinate for electronic transfer.
Please calf 42S-771-0220 to schedule an intake appointirnent!
JOB SITE INFORM ATI ON/LOCATION: (Where the work is taking place)
JobSiteAddress: `?)'?�Oq all-111 SLA)
Parcel: zLc.?oalonnop_-)oQc)
Lot /U nit/Su ite #: Subdivision:
I PROPERTY OWNER:
Name: 'E-iz � (-- 4 �q u 0 a Lfa L'L-
Mailing Address: (3q)0a 9 il_"" S T_ SO
City/State/Zip: IE')9YY)O�,30S (A)Y3r !12Laty
Phone#:
Email: CP jai I- -CO
OWNER INSTALLATION: *If yes, read and sign*
Will work be performed by the property owner? XYes 0 No
I own, reside in, or will reside in the completed structure. This
installation is being made on property that I own which is not
intended for sale, lease, rent, or exchange according to RCW
18.27.090. eg:=
Owner Signature: �11C Nnfteh0 -, n 1�, �Q?Oi
APPLICANT/ CONTACT INFORMATION: LIS4 M0lJT-)qI_M6
Name of Applicant: Hw P-ie7cH-vq,7-:nAe_,�� II- vt'5itvi
MailingAddress:
City/State/Zip:
Phorii Q 0
E-mail:
GENERAL CONTRACTOR: (if different from applicant)
General Contractor:
Mailing Address: D V
City/State/Zip:
Phone #:
E-mail:
STATE UBI M
CITY OF EDMONDS BUSINESS LICENSE M
WA STATE CONTRACTOR L & I #: (CCB) & EXPIRATION DATE:
Permit
TYPE OF PERMIT -PTovide Details on Page 2)
• Accessory Structure/ OAddition
Detached Garage
• Demolition
El Mechanical
• New Single Family / Duplex
0 Plumbing
• Fire Sprinkler
Remodel
• New Commercial/ Mixed Use
0 Re -Roof
• Signs
_13Tenant
0
ank
Improvement
Other
Remodel Permit fees are based on:
The value of the work performed. Indicate the value (rounded to
the nearest dollar) of all equipment, materials, labor, overhead,
and the profit for the work indcated on this application.
Valuation: (00j CKDO
PROPOSED NEW SQUARE FOOTAGE FOR THIS APPLICATIO�
Basement sq ft: Finished 0 Unfinished 0
Ist Floor, sq ft:
I Lisp:
2nd Floor, sqft:
Garage/Carport:, sq ft:
Deck/Covered Porch/Patio:
Other sq ft:
PROJECT DESCRIPTION
10 11A
wa.
I certify that the information I have provided on this formlapplication is true
correct and complete, and that I am the property owner or duty authorized
agent of the property owner to submit a permit application to the City of
Edmonds.
Print Name: Eric whitehead
Signature: - 816= Jan 13, 2020
Date
GENERAL COMMERCIAL DATA
Occupancy Group(s): Occupant Load(s):
TVpe(s) of Construction: Fire Sprinklers: Yes 0 No El
WA STATE ENERGY CODE: If your project affects the building envelope,
mechanical systems, and/or lighting, you must complete the
appropriate WSEC forms.
DEFERRED SUBMITTALS: All commercial building permits that will require
associated plumbing, mechanical, fire sprinkler, and/or fire alarm
permits are applied for separately.
TI / CHANGE OF USE / NEW BLDG: Include TRAFFIC IMPACT worksheet
MECHANICAL EQUIPMENT COUNTS (New and Relocated)
BTUs Gas Elec Other city
A/C Unit JCompressor
Air Handier /VAV
Boiler
Dryer Duct
Exhaust Fans
Fireplace
Furnace
Heat Pump Unit
Hydronic Heating
Roof Top Unit (Provide eleva-
tions if a Commercial Bldg)
Other:
PLUMBING FIXTURE COUNTS .'New, RelocateLdor reL-piped)
Qty Qty
'y
QJ
Clothes Washer
Tub/ Showers
Dishwasher
Backflow Device (RPBA, DCDA, AVB)
Drinking Fountain
Pressure Reduction/ Regulator Valve
Floor Drain/Sink
Refrigerator Water Supply
Hose Bibs
Water Heater - Tankless? Y or N
Hydronic Heat
Water Service Line
Sinks
Other:
T.il.ta
GAS/FUEL CONNECTION COUNTS (New, Relocated or re -piped)
BTUs Qty BTUs Qty
A/C Unit
Outdoor BBQ/ Fire pit
Boiler
Stove/Range/Oven
Dryer
Water Heater
Fireplace/ Insert
other:
Furnace
Other:
MEDICAL
GAS, AIR VACUUM COUNTS
(New,
Relocated or re -piped)
QtY Clty
Carbon Dioxide
Nitrous Oxide
Helium
Oxygen
Medical Air
Other:
Medical - Surgical Vacuum Other:
DEMOLITION
Type of structure to be demolished:
Square footage of structure to be demolished:
AHERA Survey done? Y / N
PSCAA Case #:
Critical Areas Determination:
Study Required El Conditional Waiver 0 Waiver El
Fill in Place 11 Fill Material:
Removal 13
1 Size of Tank (Gallons)
Critical Areas Determination:
Study Required El Conditional Waiver El Waiver 13
GRADE/FILL/EXCAVATE
Grading: Cut cubic yards
Fill cubic yards
Cut/ Fil I in Critical Area: Yes El No El
GENERAL PROVISIONS
APPLICATIONS: Applications arevalidfor a maximum of 1year.
ESLHA Applications, 2 years.
LICENSING: All contractors and subcontractors are required to be licensed
with Washington State Department of Labor & Industries and have a
current City of Edmonds Business License.
November 27, 2019
Attn: Natalie Griggs
City of Edmonds Engineering Division
1215 th Ave N
Edmonds, WA 98020
architecture design
I received the correction notice for project #BLD20190046 dated February 28,2019. Below are the 0 �4�-D
requested corrections and locations on the drawings where they can be found: 19 10
1. Existing curb label revised to "Ex Curb/Gutter". New curb cut/driveway has been removefkEOW B
from the project scope. Refer to 01 sheet and CSWPPP on 02 sheet.
2. New driveway has been removed from the project scope.
3. New driveway has been removed from the project scope. DEC 19 2019
4. Right of way work has been removed from the project scope. BUILDING DEPARTMENT
5. Existing Side Sewer and cleanout labelled on Site Plan and CSWPPP. Refer to 01 and 02 CITY OF EDMONDS
Sheets.
6. Existing water meter and water service line shown on Site Plan and CSWPPP. Refer to 01 and
02 Sheets.
The original project scope has been reduced/revised as follows:
A. Removal of Garage Addition and new Driveway location
B. Removal of Existing Garage remodel — Existing Garage to remain
C C. Proposed SF of Interior Remodel work: 300sf
D. Proposed Area of Addition: 114sf
All revisions are clouded on the drawings.
I can be reached at 206-S42-3734 or at heidi@h2darchitects.com with any further questions.
Regards,
Heidi Helgeson
Principal
H21) Architecture + Design
23020 Echionds Wag, -113, Edmonds, WA 98020 1 p. 206.542.3734 1 e. hed0h2dcrchftectscom I w h2duchftects.corn
simple tieating system blize: wasnington btate
This heating system siz7inq calculator is based on the Prescriptive Requirement§ of the 2015 Washington State Energy Code (WSEC) and ACCA
Manuals J and S. This calculator will calculate heating loads only. ACCA procedures for sizing cooling systems should be used to determine cooling
loads.
� fill out all of the green drop -downs and boxes that are applicable to your project. As you make selections in the drop -downs for each section,
values will be calculated for you. If you do not see the selection you need in the drop -down options, please call the WSU Energy Extension
im at (360) 956-2042 for assistance.
Project Information
Contact Infortrustion
HALL RESIDENCE
H2D ARCHITECTURE + DESIGN
8802 217TH ST SW
23020 EDMONDS WAY #113
EDMONDS, WA 98026
EDMONDS, WA 98020
Heating System Type: 0 AN Odw System
0 Heat Purnp
To see detailed instructions for each section, place your cursor on the word 'Instructions".
Design Temperature
Instructions
Design Temperature Difference (AT)
46
Seattle: Sea-Tac AP
V 1 .1,
AT= Indoor (70 dMiaes) -Outdoor Design Tamp
'�� , �_ "
Area of Building
Conditioned Floor Area
15 2019
Instructions Conditioned Floor Area (sq ft)
1,517]
JAM
Average Ceiling Height
Conditionec Volume SEFMCES
Imtru,tionr. Average Ceiling Height (ft)
7.81
11,758
DEVELOPF-Ep"r
G0U;1qEFt
Glazing and Doors
1.11-Factor
X Area
UA
In--tructlons
k
0.300
247
74.07
_Fu_-�
Skylights
U-Factor
X Area
UA
in-Aructkons
0.50
Insulation
Attic
U-Factor
X Area
UA
Imtructions R-49
0.026
F J.517
39.44
J
Single Rafter or Joist Vaulted Ceilings
U-Factor
X Area
UA
Inatructions No Vaulted Ceilings in this project.
Above Grade Walls isee Fioure i)
U-Factor
X Area
UA
Instructions
R-21 Inteffnediate
0.056
F 1J28
63.19
Floors
1.11-Factor
X Area
UA
instructions
R-30
0.029
F 446
12.75
Below Grade Walls [see Ratim 11
U-Factor
X Area
IJA
Inttructons No Below Grade Walls in this piojecL
0.028
Slab Below Grade fsee Fivure v
F-Factor
X Length
UA
Instructions No Slab Below Grade in this project.
W
0.303
Slab on Grade Is" F4� 1.)
F-Factor
X Length
UA
Instructionu No Slab on Grade in this project
Location of Ducts
Instructions
Duct Leakage Coefficient
unconditioned space
-W
1.10
Sum of UA
189.45
Envelope Heat Load
8,715
Btu I Hour
Figure I Surnof UAXAT
Air Leakage Heat Load
5,841
Btu I Hour
VOILHWX 0.6XATX.018
Above Gmde Building Design Heat Load
14,556
Btu i Hour
Air Leakage - Envelope Heat Loss
Building and Duct Heat Load
16,011
Btu/Hour
Ducts in unconditioned space Surn of Building Heat Loss X 1, 10
Ducts in conditioned spaw Sum of Bwkfing Heat Low X I
Maximum Heat Equipment Output
22,416
Btu/ Hour
Building and Duct Heat Loss X 1� 40 for Forced Air Furnace
Building and Duct Heat Loss X 1. 25 for Heat Pump
(07AIIIJ3)
`�'?rescriptive Energy Code Compliance for All Climate Zones in Washington
Project Information
Contact Information
HALL RESIDENCE
H2D ARCHITECTURE + DESIGN
8802 217TH ST SW
23020 EDMONDS WAY #113
EDMONDS, WA 98026
EDMONDS, WA 98020
This project will use the requirements of the Prescriptive Path below and incorporate the
the minimum values listed. In addition, based on the size of the structure, the appropriate
number of additional credits are checked as chosen by the permit applicant.
Authorized Representative
All Glimate Zones
R-Value�
1-11-Factor
Fenestration U-Factor"
n/a
0.30
Skylight U-Factor
n/a
0.50
Glazed Fenestration SHGCD,'-'
n/a
n/a
Ceilingk
44
0-026
Wood Frame Wall"'
21 int
0�056
Mass Wall R-Value'
21/21n
0.056
Floor
......................................... . . 7
30
0.029
Below Grade Wall'
10/15/21 int + TB
0.042
1SIab' R-Value & Depth
10, 2 ft
n/a
*Table R402. 1 � 1 and Table R402.1.3 Footnotes included on Page 2.
Date
JAN 15 2919
DEVELOPMENT SERVICES
C=ffER
�Each dwelling unit in a residential building shall comply with sufficient options from Table R406.2 so as to achieve
the following minimum number of credits:
1. Small Dwelling Unit: 1.5 credits
F-1 Dwelling units less than 1500 square feet in conditioned floor area with less than 300 square feet of
fenestration area. Additions to existing building that are greater than 500 square feet of heated floor area but
less than 1500 square feet.
E12. Medium Dwelling Unit: 3.5 credits
All dwelling units that are not included in #1 or #3. Exception: Dwelling units serving R-2 occupancies shall
require 2.5 credits.
n3. Large Dwelling Unit: 4.5 credits
Dwelling units exceeding 5000 square feet of conditioned floor area.
Additions less than 500 square feet: .5 credits
Table R406.2 Summary
Option Description
Credit(s)
la
Efficient Building Envelope la
0.5
1 b
Efficient Building Envelope lb
1.0
Ic
Efficient Building Envelope 1c
2.0
Id
Efficient Building Envelope ld
O�5
2a
Air Leakage Control and Efficient Ventilation 2a
0.5
2b
Air Leakage Control and Efficient Ventilation 2b
1.0
2c
Air Leakage Control and Efficient Ventilation 2c
1.5
3a
High Efficiency HVAC 3a
1.0
3b
High Efficiency HVAC ib
1.0
3c
High Efficiency HVAG 3c
1.5
3d
High Efficiency HVAC 3d
1.0
4
High Efficiency HVAC Distribution System
1.0
5a
Efficient Water Heating 5a
0.5
5b
Efficient Water Heating 5b
1'0
5c
Efficient Water Heating 5c
1.5
5d
Efficient Water Heating 5d
0.5
6
Renewable Electric Energy
O�5
Cl
1:1
F
El
F-1
F�
0.5
1.0
*1200 kwh 0.0
Total Credits 1.50
*Please refer to Table R406.2 for complete option descriptions
1
For SI: 1 foot.= 304.8 mm, ci.= continuous insulation, int.= intermediate framing.
' R-values are minimums. U-factors and SHGC are maximums. When insulation is installed in a cavity which is
less than the label or design thickness of the insulation, the compressed R-value of the insulation from
Appendix Table A101.4 shall not be less than the R-value specified in the table.
b The fenestration U-factor column excludes skylights. The SHGC column applies to all glazed fenestration.
c "10/15/21.+TB" means R-10 continuous insulation on the exterior of the wall, or R-15 on the continuous
insulation on the interior of the wall, or R-21 cavity insulation plus a thermal break between the slab and the
basement wall at the interior of the basement wall. "10/15/21.+TB" shall be permitted to be met with R-13
cavity insulation on the interior of the basement wall plus R-5 continuous insulation on the interior or exterior
of the wall. "10/13" means R-10 continuous insulation on the interior or exterior of the home or R-13 cavity
insulation at the interior of the basement wall. '713" means thermal break between floor slab and basement
wall.
d R-10 continuous insulation is required under heated slab on grade floors. See 11402.2.9.1.
e There are no SHGC requirements in the Marine Zone.
f Reserved.
6 Reserved.
h Reserved.
'The second R-value applies when more than half the insulation is on the interior of the mass wall.
i Reserved.
k For single rafter- or joist -vaulted ceilings, the insulation may be reduced to R-38.
I Reserved.
M Int. (intermediate framing) denotes standard framing 16 inches on center with headers insulated with a
minimum of R-10 insulation.
a Nonfenestration U-factors shall be obtained from measurement, calculation or an approved source or as
specified in Section R402.1.3.
4
r
Harriott Valentine Engineers Inc.
STRUCTURAL CALCULATIONS
Project:
Whitehead Remodel
8802 217th St. SW
Edmonds WA, 98026
Architect:
H2D Architecture + Design
23020 Edmonds Way #113
Edmonds, WA 98020
tel. 206-542-3734
Structural Engineer:
Harriott Valentine Engineers, Inc,
1932 First Avenue, Suite 720
Seattle, WA 98101
tel. 206-624-4760
29 a i9
12117119
DEC 19 2019
BUILDING DEPARTMENT
ary OF EDMONDS
1932 First Avenue, Suite 720
Seattle, Washington 98101-2447 12113/2019
tel. 206-624-4760 1 fax 447-6971 ao (4 Page _ of _
Harriott Valentine Engineers Inc.
SECTION 1: GENERAL
1932 First Avenue, Suite 720
Seatfie, Washington 98101-2447 2018-12-13
tel. 206-624-4760 1 fax 447-6971 Page _ of _
Harriott Valentine Engineers Inc.
CRITERIA
Gravity
roof dead
asphalt shingles
1/2" plywood
R30 insulation
Prefab Trusses
5/8" gyp. wallboard
slope factor
miscellaneous
total dead + live
walls @ existing house
8" CMU grouted @ 48" oc
4" brick veneer
2x6 @ 16"oc
R21 insulation
1/2" gyp, wallboard
i-niscellaneOLIS
floor @ addition
3/4" hardwood
3/4" plywood sheathing
2x8 @ 16" oc
miscellaneous
total dead + live
2�5
1�5
1.2
5.0
2.8
0.9
0.1 1%
14.0 psf
39.0 psf
live snow 25�O psf
38.0
39.0
1.7
0.8
2.2
1, 3 pSf 2%
83.0
3.0
2.3
2.2
2.5 25%
10.0 psf
50.0 psf
live residential 40 psf
1932 First Avenue, Suite 720
Seattle, Washington 98101-2447 1211312019
tel 206-6244760 1 fax 447-6971 Page _ of _
Harriott Valentine Engineers Inc.
Lateral
wind wind importance factor
1.0 mph
basic wind speed
110
wind exposure
B
topographical factor (Kzt)
1.38
seismic seismic importance factor
1.0 0
latitude
47.802 0
longitude
-122.352 g
mapped spectral response
1.267
accel. at short periods (Ss)
seismic design category
D
response modification factor (R)
6.5
(from USGS)
1932 First Avenue, Suite 720
Seattle, Washington 98101-2447 12113/2019
let 206-624-4760 1 fax 447-6971 Page _ of
Design Maps Summary Report
https:Hprod02-earthquake.cr.Lisus.gov/designmaps/us/sumiiiary.php
C,
E,= Design Maps Summary Report
User —Specified Input
Building Code Reference Document 2012/2015 International Building Code
(which utilizes USGS hazard data available in 2008)
Site Coordinates 47.802260N, 122.35232OW
Site Soil Classification Site Class D - "Stiff Soil"
Risk Category I/II/III
TKU MIIMI'W�
cokv C)RT
PORTOANDLE
�,k*nnw
Al
Eftokko
TO
Jk
76da ta''
V
RES EPVA
r�e in
USGS—Provided Output
Ss = 1.267 g Sms = 1.267 g Sos = 0.844 g
S, = 0.495 g Sm, = 0.745 g So, = 0.497 g
For information on how the SS and S1 values above have been calculated from probabilistic (risk -targeted) and
deterministic ground motions in the direction of maximum horizontal response, please return to the application and
select the "2009 NEHRP" building code reference document.
NtCE,t Response Spectrum
1.43
I � 4
I 1�3' 1 A' I 4L' 10" ZA'�
Pcrkid, T isto
.4�
.36
Design Response Spectrum
";4' 1 ".' 1'3L� I 'P' I f, � I
Pci*W, T Ism)
.... . ..... . ... ....
Although this information Is a product of the U.S. Geological Survey, we provide no warranty, expressed or implied, as to the accuracy of
the data contained therein. This tool is not a substitute for technical subject -matter knowledge.
I of I IMIR-11-111 1;.CQ
Harriott Valentine Engineers Inc.
CRITERIA
Gravity
roof dead
asphalt shingles
1/2" plywood
R30 insulation
Prefab Trusses
5/8" gyp. wallboard
slope factor
miscellaneous
total dead + live
walls @ existing house
8" CMU grouted @ 48" oc
4" brick veneer
2x6 @ 16"oc
R21 insulation
1/2" gyp, wallboard
miscellaneous
floor @ addition
3/4" hardwood
3/4" plywood sheathing
2x8 @ 16" oc
miscellaneous
total dead + live
2.5
1.5
1.2
5.0
2.8
0.9
O'l 1%
14.0 psf
39.0 psf
live snow 25.0 psf
38,0
MO
1.7
0.8
2.2
1.3 pSf 2%
83.0
3.0
2.3
2.2
2.525%
10.0 psf
50.0 psf
live residential 40 psf
1932 First Avenue, Suite 720
Seattle, Washington 98101-2447 12/13/2019
tel 206-624-4760 1 fax 447-6971 Page _ of _
Harriott Valentine Engineers Inc.
Lateral
wind wind importance factor
1.0 mph
basic wind speed
110
wind exposure
B
topographical factor (Kzt)
1�38
seismic seismic importance factor
1.0 0
latitude
47.802 0
longitude
-122.352 g
mapped spectral response
1267
accel. at short periods (Ss)
seismic design category
D
response modification factor (R)
6.5
(from USGS)
1932 First Avenue, Suite 720
Seattle, Washington 98101-2447 12113/2019
tel 206-624-4760 1 fax 447-6971 Page — of —
Harriott Valentine Engineers Inc.
SECTION 2: FRAMING
1932 First Avenue, Suite 720
Seattle, Washington 98101-2447 2018-12-13
tel. 206-624-4760 1 fax 447-6971 Page _ of _
(f, i 91
. ... ... ................ ..
If
So
-- - - - - - - - - - - - - - - - -
GARAGE
LXF
an
0,
ns
/t/ 3
LIVING BEDROOM
CL.or
HALL
mkl%vooro 0
S ir z e SvXmp LVSIW.l .9
f-0.
M. BEDROOM
:z I BA-M 2
KITCHEN 'I M. CLO
Q;DiiARDAWD
PW
X-1 z'L',
EXISID6
1175T
61 1 (b
Harriott Valentine Engineers Inc.
SECTION 3: LATERAL
1932 First Avenue, Suite 720
Seattle, Washington 98101-2447 2018-12-13
tel. 206-624-4760 1 fax 447-6971 Page _ of _
Harriott Valentine Engineers Inc.
SEISMIC DESIGN
ASCE 7-10
Equivalent Lateral Force Procedure
Occupancy Category
Seismic Design Category
Importance Factor
Site Class
Ss
S1
Fa
Fv
Ct
X
hn
Sms = Fa*Ss
Smi = Fv*S1
SDs = (2/3)*Sms
SD1 = (2/3)*Smi
Period Ta = Ct*h nAX
To
Ts
Sa
11
Table 1-1
D
Table 11 �6-1
1,00
Table 11.5-1
D
Table 20.3-1
126,70 %g
(from USGS Seismic Hazard Curves, 2008 data)
49.50 %g
(from USGS Seismic Hazard Curves, 2008 data)
1.00
Table 11.4-1
1.50
Table 11.4-2
0,02
Table 12.8-2
0.75
Table 12.8-2
13.33 feet
(height to highest level)
1.2670
Eq. 11.4-1
0.7425
Eq. 11.4-2
0,8447 g
Eq. 11.4-3
0,4950 g
Eq. 11.4-4
0.1395 s
Eq. 12.8-7
0.1172 s
per section 11.4.5
0.5860 s
per section 11.4.5
O�8447 g
per section 11.4.5
R
&5
Table 12.2-1
no
2.5
Table 12.2-1
Cd
4
Table 12.2-1
Section 9.5.5 ok?
Yes
Table 12.6-1
Equivalent Lateral Force Procedure (section 12.8)
Cs 0.1299 Eq. 12.8-2
1932 First Avenue, Suite 720
Seattle, Washington 98101-2447
let. 206-624-4760 1 fax 447-6971
2018-12-14
Page _ of _
Harriott Valentine Engineers Inc.
WIND DESIGN
ASCE 7-10
Simplified Envelope Method (Chapter 28)
ps = Kztl ps3o
Part of Figure 28.6-1 - Adjustment Factor
for Building Height and Exposure, .,
Mean Roof Height
Exposure
(ft)
B
=C
15
1.00
1 1,21
1 1,47-
16
1.00
1.23
1.49
17
1.00
1,24
1.50
18
1.00
1.26
1.52 1
19
1.00
1.27
1.53
20
1.00
1,29
1,55
21
1.00
_-T
_30
1.56
2 �__
0 _0
.31
1.57
23
1.66--7�3-3
1.59
24
1.00
34
1.60
25
1.00
1 35
1.61
26
1.00
1.36
_7�6_2
27
1.00
1.37
1.63
28
1.00
1.38
1
1.641
29
1.00
1.39
1.65
30
1,00
1,40
1.66
Part of Figure 28.6-1 - Method 2
Desian Wind Presqtjrp nein
I = adjustment factor
1,00
I =importance factor=
1,00
Kzt = topographic factor
1 67
Zone
Computation
a = 10% of least horizorW dimension or
0.4 x h, whichever is smaller, but not less
than either 4% of least horizontal dimen-
sion or 3 feet,
W 26.00 ft x O.'� =
h 10. 50 ft X 0.4 =
W 26,00 ft x 0.04
a = 3.00 ft
2a 6.00 ft
Zone B - end zone of roof
Zone A - end zone of wall
Zone D - interior zone of roof
Zone C - interior zone of wall
Basic
Speed
1koof
Angle
Roof
Pitch
Horizontal Pressures (P
A
B
C
D
110
0 to 5
flat
19.2
_10,0
127
-5,9
10
2-
21.6
-9.0
14.4
-5.2
15
3
24.1
-8.0
16.0
-4.6
20
4
26.6
-TO
17.7
-3-9
25
-to45
6
24� 1
19 .
17.4
4-0
7 to 12
2-1.6
14.8
17.2 1
11.8
Desion Wind Pressure. ns
Basic
Speed
Roof
Angle
Roof
Pitch
Horizontal Pressures (psf)
A
C
D
0 to 5
flat
321
-16.7
21 �2
-9.9
10
2
36.1
-15.0
24.0
-8.7
110
15
3
40.2
-13.4
26-7
-7.7
20
4
44.4
-11.7
29.6
-6.5
25
6
40.2 1
6.5
29.1
U
30 to 45
7 to 27
36.1 1
24.7
2&7
19.7
2.60 ft
4.20 ft
1,04 ft
1932 First Avenue, Suite 720
Seattle, Washington 98101-2447 2018-12-14
tel 206-624-4760 1 fax 447-6971 Page - of -
Harriott Valentine Engineers Inc.
A rc1rL ( ' 2- 16
F. 'Op -�-'
13-30
f
2-
0-70
1932 First Avenue, Suite 720
Seattle, Washington 98101-2447
tel. 206 624 4760 1 fax 447 6971
Harriott Valentine Engineers Inc.
-3.
g' �" - t —___ "' r, q, / we 5i� wl 5
Q
1_2
rip-
�'0411w)
C 19.
t T.'
/x 47
f4)( -P. c/4-ot,.t,�
2- 3-9 JP6 (/j
-=- �_)_!:�'q F" wv
0 C' / i 'q /f/ p " -/ I-) /:"-, "-/ P) 01. 1.,
2-)l helt ? -&y,� Ct L WI,))12-
1�' P_�V_C' walt If , ke, (04 W)
1932 First Avenue, Suite 720
Seattle, Washington 98101-2447 VA h C(k
tel. 206 624 4760 1 fax 447 6971
Harriott Valentine Engineers Inc.
:5hc ct r' woli L-c--, ,r . r, I-
L
/f/0 r-7'h VV'a It L (' I'N C, A/ _--1-2 �
1/) 4 /t/—:�' — 1 -7 -5 17"
'A qctA,-,,j 8�
1--;> L
TZ /tl\
f�T
7 0 I'l
q1"fj ka = ", , �T I-) . L-/ p ( �-
V el, 11 T�'fL- -: i,\) 1 � 3 .7; -7 )
0: T// zu it,
DT/A - 0
q 5-
0 A (K
oq k 1�)( I �, 2
o-r/vk 4 - (.6
Pi- I,-/
fZ- 1A
'� �-5'1 T f — Ito
'- i 111 '/1
�? 0 '? q t�
1932 First Avenue, Suite 720 tyr/�
Seattle, Washington 98101-2447
tel. 206 624 4760 1 fax 447 6971 Dec —
Harriott Valentine Engineers Inc.
Vw"L;,(
53 7
cylt�
........ .
eD - U,3-9-
fil;� ft—
-7 0
We, TIPC
YA!,
07-;'v\ 0.
C)T/vk
--7
F W , Ll 3,?-B I �7
V1
TH -
1932 First Avenue, Suite 720
Seattle, Washington 98101-2447 1A)j)
tel. 206 624 4760 1 fax 447 6971
Harriott Valentine Engineers Inc.
&C"(- mot
VIOU57-
�)OV2-- VplJT
'�. I r,
3:7-"S-3
�f� lz�-1:51 I's
13 \-) ' ( ) to
ly 1h.
r p r-') Y" \1
'�� ('k
1932 First Avenue, Suite 720 4-c- kct
Seattle, Washington 98101-2447
tel. 206 624 4760 1 fax 447 6971
Harriott Valentine Engineers Inc.
SECTION 4: FOUNDATION
1932 First Avenue, Suite 720
Seattle, Washington 98101-2447 2018-12-13
tel. 206-624-4760 1 fax 447-6971 Page _ of _
E=Anchor DesignerTl"
Software
Version 2,6.6794.66
I.Prolect information
Customer company:
Customer contact name:
Customer e-mail:
Comment:
2. Input Data & Anchor Parameters
General
Design method:ACI 318-11
Units: Imperial units
Anchor Information:
Anchor type: Cast -in -place
Material: AB H
Diameter (inch): 0.625
Effective Embedment depth, ho (inch): 5.000
Anchor category'. -
Anchor ductility: Yes
h n (inch): 7.13
Cmen (inch): 1.38
S�In (inch): 2.50
Company:
I Date:
11211612019
Engineer.
Page:
11/5
Project:
Address:
Phone:
E-mail:
Recommended Anchor
Anchor Name: PAB Pro -Assembled Anchor Bolt - PAB5H (5/8"121)
Project descriptiow HDU5 Cast -in
Location:
Fastening description:
Base Material
Concrete: Normal -weight
Concrete thickness, h (inch): 24.00
State: Uncracked
Compressive strength, fc (psi): 2500
4)�,v: 1.0
Reinforcement condition: B tension, B shear
Supplemental reinforcement: No
Reinforcement provided at comers: No
Ignore concrete breakout in tension: No
Ignore concrete breakout in shear. No
Ignore 6do requirement: Yes
Build-up grout pad: No
... .. ......
Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility.
5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.stronglie.com
Anchor DesignerTm
Software
Version 2.6.6794.66
Load and Geometry
Load factor source: ACI 318 Section 9.2
Load combination: not set
Seismic design: No
Anchors subjected to sustained tension: Not applicable
Apply entire shear load at front row: No
Anchors only resisting wind and/or seismic loads: No
Strength level loads:
Nua [lb]: 3783
Vuax 11b]: 0
Way jib): 0
<Figure 1>
X
0 1b
Company:
::��i
2/1612019
Engineer:
Page:
12/5
Project:
Address:
Phone*
tE-7m a i L'
z
3783 lb
I
3.00
3,00 --- Gib
24.00
Y
Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility.
3irr.r. -.c,n Svel-i - -3 - T - Gui n par ; .1 1 , 5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www,strongtie.com
'U1;&-19JOE Anchor Designer TM
Software
Version 2.6.6794.66
<Figure 2>
Company:
jDate:
112/16/2019
Engineer:
I Page:
1315
Project:
Address:
Phone-
FE-maT
Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility.
5956 W, Las Positas Boulevard Pleasanton, CA 94588 Phone: 925,560,9000 Fax: 925.847.3871 www.strongUe.com
Anchor Designer TM
Software
Version 2.6.6794.66
Company:
Date:
112/16/2019
Engineer:
I Page:
14/5
Project:_
Address:
Phone:
E-mail:
3. Resulting Anchor Forces
Anchor Tension load, Shear load x, Shear load y, Shear load combined,
%� (lb) Vu.� (lb) VURY (lb) -'/(VUU)4(Vu.y)1 (lb)
1 37810 0.0 0.0 0.0
Sum 3783.0 0.0 0.0 0.0
Maximum concrete compression strain (0/6): 0.00
Maximum concrete compression stress (psi): 0
Resultant tension force (lb): 3783
Resultant compression force (lb): 0
Eccentricity of resultant tension forces in x-axis, e'W (inch): 0.00
Eccentricity of resultant tension forces in y-axis, e'NY (inch): 0.00
4. Steel Strength of Anchor in Tension (Sec, Q.5.11)
Nsa (1b) 0 ^9 (lb)
27120 0.75 20340
5. Concrete Breakout Strength of Anchor in Tension (Sec. D.5.2)
Nb = k,;..�f.hal I (Eq. D-6)
kc )a Fc (psi) he (in)
Nb (lb)
24.0 1.00 2500 5.000
13416
ONcb = 0 (AYc1Aavca)%"ed.mY1c,0vcp.NNb (Sec, D.4.1 & Eq. D-3)
ANc (in 2) AN,. (in') c.,.o (in) 'P.d.N
W.:,N Y�Pv Nh (lb) 0 ONcb (lb)
100.50 225.00 3.00 0.820
1.25 1,000 13416 0.70 4300
6. Pullout Strength of Anchor in Tension (See. D.5.31
ONpn = O'Pc.pNp = �KPI]lAbr9rc (Sec, D.4.1, Eq. D-13 & D-14)
T', P Abg (in 2) F� (psi) 0 OiYp� (I b)
1.4 2.10 2500 0.70 41121
Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility.
!"—n ;1, 5956 W. Las Posilas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.B47.3871 www.strongtie.com
Anchor Designer TM
Software
Version 2.6.6794.66
Company:
Date:
12116/2019
Engineer:
Page:
515
Project:
Address:
Phone:
rE
11. Results
11. Interaction of Tensile and Shear Forces (Sec. D.7)?
Tension
Factored Load, N�. (lb)
Design Strength, o% (lb)
Ratio
Status
Steel
3783
20340
0.19
Pass
Concrete breakout
3783
4300
0.88
Pass (Governs)
Pullout
3783
41121
0.09
Pass
PABSH (5/8"0) with hef = 5.000 Inch meets the selected design criteria.
12. Warnincis
- Minimum spacing and edge distance requirement of Eida per ACI 318 Sections D.8.1 and D.8.2 for torqued cast -in -place anchor is waived per
designer option.
- Designer must exercise own judgement to determine if this design is suitable.
Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility.
T 5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone-, 925.560.9000 Fax: 925,847.3871 www.strongtie.com
Anchor DesignerT11
Software
Version 2.6.6794.67
1.Project information
Customer company:
Customer contact name:
Customer e-mail:
Comment:
2. Input Data & Anchor Parameters
General
Design mothod:ACI 318-11
Units: Imperial units
Anchor Information:
Anchor type: Bonded anchor
Material: F1554 Grade 36
Diameter (inch): 0.625
Effective Embedment depth, her (inch): 12.500
Code report: ICC-ES ESR-2508
Anchor category: -
Anchor ductility: Yes
h�;n (inch): 15.63
c.. (inch): 27.54
C�A (inch): 1.75
Sml� (inch): 3.00
Recommended Anchor
Anchor Name: SET-XPO - SET-XP wl 5/8"0 F1 554 Gr. 36
Code Report: [CC -ES ESR-2608
ME]
Company:
Date:
12/1612019
Engineer:
Page:
1/5
Project:
Address:
Phone-
rE-maiV'
Project description: HDU4 Epoxy
Location:
Fastening description:
Base Material
Concrete: Normal -weight
Concrete thickness, h (inch): 24.00
State: Uncracked
Compressive strength, f � (psi): 2500
4)c,v: 1.0
Reinforcement condition: B tension, B shear
Supplemental reinforcement: No
Reinforcement provided at comers: No
Ignore concrete breakout in tension: No
Ignore concrete breakout in shear: No
Hole condition: Dry concrete
Inspection! Continuous
Temperature range, Short/Long: 110/75*F
Ignore 6do requirement: Not applicable
Build-up grout pad: No
Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility.
7,0 u, :-, 31('�:, - 1,
:�, 5956W. Las Positas Boulevard Pleasanton. CA94588 Phone: 925.660.9000 Fax:925,847.3871 wArw.stronglie.comr
Anchor Designer"m
Software
Version 2.6.6794.67
Load and Geometry
Load factor source: ACI 318 Section 9.2
Load combination: not set
Seismic design: No
Anchors subjected to sustained tension: No
Apply entire shear load at front row: No
Anchors only resisting wind and/or seismic loads: No
Strength level loads:
Nua [1b]: 2783
V... [lb]: 0
VUaY [lb]: 0
<Figure 1>
z
01b
X
Company;
Date:
112/16/2019
Engineer:
Page:
1215
Project:
Address:
Phone:
r&-mail,l
2783 lb
I
3.00
3.00 Olb
i Y
24.00
Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility.
3-'n- - n S'n I '. - 5956 W. Los Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 225.847.3871 www.strongtie.com
Anchor DesignerTm
Software
Version 2.6.6794.67
<Figure 2>
Company:
I Date: J�/261
9
Engineer:
I Page:
13/5
Project:
Address:
Phone:
E-mail:
Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility.
S�a— 5956 W Las Posilas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com
Anchor DesignerTM
Software
Version 2.6.6794.67
Company:
ate:
112116/20119
Engineer:
Page:
14/5
Project:
Address:
Phone:
�E-mail:
3. Resulting Anchor Forces
Anchor Tension load, Shear load x, Shear load y, Shear load combined,
&,, (lb) V... (lb) Way (lb) N(Vuax)2+(Vu,,y)2 (lb)
1 27810 0.0 0.0 0.0
Sum 2783,0 0.0 0.0 0.0
Maximum concrete compression strain (%.): 0.00
Maximum concrete compression stress (psi): 0
Resultant tension force (lb): 2783
Resultant compression force (lb): 0
Eccentricity of resultant tension forces in x-axis, &N� (inch): 0.00
Eccentricity of resultant tension forces in y-axis, e'NY (inch): 0.00
4. Steel Strength of Anchor in Tension (Sec. D.5.1
N.. (lb) (lb)
13110 0.75 9833
5. Concrete Breakout Strenqth of Anchor in Tension (Sec. D.5.2)
Nb = k,)..vF�h.il 5 (Eq, D-6)
kc Aa f� (psi) h.f (in) Nb (lb)
24.0 1.00 2500 12.500 53033
ON,b = 0 (ANc1AN�)Wed.NY1c.NV-1�p.NNb (Sec. D.4.1 & Eq. D-3)
ANc (in 2) ANco (in 2) c.,.i. (in) PedN 'PC, N SP.,v Nb (lb) 0 ONcb (1b)
225.00 1406.25 3.00 0.748 1.00 0.681 53033 0.65 2808
6. Adhesive Stren_qth of Anchor in Tension (Sec. D.5.5)
A.uncr = rk,unafshott-laimKsal
rk.V�Cl (psi) fshfi-fe- Ksai rk..�, (Psi)
2046 1.00 1.00 2046
Nb. r.-zrdh&(Eq. D-22)
) a r.- (psi) d. (in) kf (in) Nb. (lb)
1.00 2046 0.63 12.500 50216
^ = 0 (ANalANno)Tedwa TcpwaNb. (Sec. D.4.1 & Eq. 0-18)
AN. (in 2) Aivo (in') cm, (in) ca,.ift (in) %dpa VCP'Na Nb. (lb) 0 ON. (lb)
102.29 290.63 8.52 3.00 0.806 0.309 50216 0.65 2864
Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility.
5956W. Las Positas Boulevard Pleasanton, CA94588 Phone: 925.560.9000 Fax:925.847.3871 www.strongtie.corn
Anchor Designer TM
Software
Version 2.6.6794.67
Company:
JDate:
112/1612019
Engineer:
Page:
15/5
Project:
Address:
Phone:
E-I,,
F M�7
11. Results
11. Interaction of Tensile and Shear Forces (Sec. D.717
Tension
Factored Load, N�. (lb)
Design Strength, oNn (lb)
Ratio
Status
Steel
2783
9833
0.28
Pass
Concrete breakout
2783
2808
0.99
Pass (Governs)
Adhesive
2783
2864
0.97
Pass
SET-XP w/ 518"0 F1554 Gr. 36 with hef = 12.500 inch meets the selected design criteria.
12. Warnings
- When cracked concrete is selected, concrete compressive strength used in concrete breakout strength in tension, adhesive strength in tension
and concrete pryout strength in shear for SET-XP adhesive anchor is limited to 2,500 psi per ]CC -ES ESR-2508 Section 5.3.
- This temperature range is currently outside the scope of ACI 318-14/-11 and ACI 355.4. Designer must exercise judgement to determine if this
design is suitable.
- Minimum spacing and edge distance requirement of 6da per ACI 318 Sections D.8.1 and D.8.2 for torqued cast -in -place anchor is waived per
designer option.
Designer must exercise own judgement to determine if this design is suitable.
Refer to manufacturer's product literature for hole cleaning and installation instructions.
Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility.
;r -"t . '>7 -�'i ili� 'r, :1 5956 W. Las Posilas Boulevard Pleasanton, CA 94588 Phone: 925.560,9000 Fax: 925.847.3871 www.strongtie.com
Anchor Designer TM
Software
&7�77 'K\\7'7R'\7fl
Version 2.6.6794.68
I.Proiect information
Customer company:
Customer contact name:
Customer e-mail:
Comment:
Company:
Date:
Engineer*
Page:
11/5
Project:
Address:
Phone.
E-mail:
Project description: HDU4 Cast in
Location:
Fastening descriptiow
2. Input Data & Anchor Parameters
General
Base Material
Design method:ACI 318-11
Concrete: Normal -weight
Units: Imperial units
Concrete thickness, h (inch): 24.00
State: Uncracked
Anchor Information:
Compressive strength, 17, (psi): 2500
Anchor type: Cast -in -place
4)�'v: 1.0
Material: AB
Reinforcement condition: B tension, B shear
Diameter (inch): 0.625
Supplemental reinforcement: No
Effective Embedment depth, he (inch): 4.000
Reinforcement provided at comers: No
Anchor category, -
Ignore concrete breakout in tension: No
Anchor ductility: Yes
Ignore concrete breakout in shear: No
hr�m (inch): 6.13
Ignore 6do requirement: Yes
C,K,� (inch): 1,38
Build-up grout pad: No
S.i. (inch): 2.50
Recommended Anchor
Anchor Name: PAB Pre -Assembled Anchor Bolt - PAB5 (5/8"0)
Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility.
S"'nP5,A) 5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax; 925.847.3871 www.strongtie.com
Anchor Designer TM
Software
Version 2.6.6794.68
Load and Geometry
Load factor source. ACI 318 Section 9.2
Load combination: not set
Seismic design: No
Anchors subjected to sustained tension: Not applicable
Apply entire shear load at front row: No
Anchors only resisting wind and/or seismic loads: No
Strength level loads:
N�� [1b]: 2783
Wax [lb): 0
VURY [1b]; 0
<Figure 1>
0 1b
Company:
I Date:
112/16/2019
Engineer:
I Page:
12/5
Project-,
Address:
Phone:
E-mail:
2783 lb
I
3.00
3.00 444� 0 1b
24X0
Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility.
3.;w:s,�n Sir-,no-T.a C --rar�, 1. 5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 %,Avw.strongtie.com
Anchor Designer TM
Version 2.6.6794.68
<Figure 2>
Company:
I Date:
112/1612019
Engineer:
I Page:
1315
Project:
Address:
Phone:
rE maiV
Input data and results must be checked for agreement with the existing circumstances. the standards and guidelines must be checked for plausibility.
3z-t, 5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560,9000 Fax: 925.847.3871 www.stronglie.com
Anchor Designer TM
Software
Version 2.6.6794.68
Company:
—��12/16/2019
Engineer:
Page:
14/5
Project:
Address:
Phone:
TE-mall,
3. Resulting Anchor Forces
Anchor Tension load, Shear load x, Shear load y, Shear load combined,
Nun (lb) W. (lb) VUSY (I b) q(V...)1+(V.�y)2 (lb)
1 2783.0 0�0 0.0 0.0
Sum 2783.0 0,0 0.0 0.0
Maximum concrete compression strain (%.): 0.00
Maximum concrete compression stress (psi): 0
Resultant tension force (lb): 2783
Resultant compression force (lb): 0
Eccentricity of resultant tension forces in x-axis, e'w (inch): 0.00
Eccentricity of resultant tension forces in y-axis, e'NY (inch): 0.00
4. Steel Strength of Anchor in Tension (See. Q.5.1)
Nsa (1b) 0 ON," (I b)
13100 0.75 9825
5. Concrete Breakout Strength of Anchor in Tension (See. D.5.21
Nb = k,)..� , f�ha` (Eq. D-6)
kc 20 rc (psi) Nf (in)
Nb (lb)
24.0 1.00 2500 4.000
9600
ONcb = 0 Om�l Anw) Yled.m 7'cjv Yl�p.NNb (Sec. D.4.1 & Eq. D-3)
AN, (in2) Am. (in 2) c�,.i� (in) %dA
PC"V KPN Nb (lb) 0 ONo (1b)
82.50 144.00 3.00 0.850
1.25 1.000 9600 0.70 4091
6. Pullout Strenath of Anchor in Tension (See. D.5.31
^� = �'PcpNp = OP�.PBAwgf� (Sec. 0.4.1, Eq. D-13 & 0-14)
we. P A&g (0) f, (psi) 0 ONp. (lb)
1.4 2.10 2500 OJO 41121
.......... ... .... ..
Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility.
5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 YAvw.s1rongtie.com
Anchor Designer TM
Software
Version 2.6.6794.68
Company:
JDate:
112/16/2019
Engineer:
Page:
15/5
Project:
Address:
Phone:
E-mail:
11. Results
11. Interaction of Tensile and Shear Forces (See. D.7)?
Tension
Factored Load, Nua (lb)
Design Strength, oNn (lb)
Ratio
Status
Steel
2783
9825
0.28
Pass
Concrete breakout
2783
4091
0.68
Pass (Governs)
Pullout
2783
41121
0.07
Pass
PA135 (5/8"0) with hef = 4.000 inch meets the selected design criteria.
12. Warnings
- Minimum spacing and edge distance requirement of 6da per ACI 318 Sections D.B.1 and D.8.2 for torqued cast -in -place anchor is waived per
designer option.
- Designer must exercise own judgement to determine if this design is suitable.
Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility.
, '31, .� ' .' G. , , 5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.stronglie.com
Anchor Designer T11
Software
Version 2.6.6794.70
I.Proiect information
Company:
I Date:
112/16/2019
Engineer:
Page:
11/5
Project:
Address:
Phone:
rE-m
Customer company: Project description: HDU2 Cast in
Customer contact name:
Customer e-mail: Location:
Comment: Fastening description:
2. InDut Data & Anchor Parameters
General
Base Material
Design method:ACI 318-11
Concrete: Normal -weight
Units: Imperial units
Concrete thickness, h (inch): 24.00
State: Uncracked
Anchor Information:
Compressive strength, f. (psi): 2500
Anchor type: Cast -In -place
4),v: 1.0
Material: AB
Reinforcement condition: B tension, B shear
Diameter (inch): 0.625
Supplemental reinforcement: No
Effective Embedment depth, hes (inch): 4.000
Reinforcement provided at comers: No
Anchor category: -
Ignore concrete breakout in tension: No
Anchor ductility: Yes
Ignore concrete breakout in shear: No
h�;n (inch): 6.13
Ignore 6do requirement: Yes
C�zn (inch): 1.38
Build-up grout pad: No
S.;� (inch): 2.50
Recommended Anchor
Anchor Name: PAB Pre -Assembled Anchor Bolt - PAB5 (5/8"0)
Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility.
5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com
Anchor DesignerTM
Software
Version 2.6.6794.70
Load and Geometry
Load factor source: ACI 318 Section 9.2
Load combination: not set
Seismic design: No
Anchors subjected to sustained tension: Not applicable
Apply entire shear load at front row: No
Anchors only resisting wind and/or seismic loads: No
Strength level loads:
Nua [lb]: 1341
V... [lb]: 0
V..y [1b]: 0
<Figure 1>
X
01b
Company:
�Date.
12/16/2019
Engineer:
Page:
2/5
Project:
Address:
Phone:
P
1341 lb
I
3.00
3.00 4%�� 0 1b
74.00
Y
Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility.
5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com
Anchor Designer T11
o ware
Version 2.6.6794.70
<Figure 2>
Company:
2116/2019
Engineer:
I Page:
1315
Project:
Address:
Phone:
E-mail:
Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility.
5956 W, Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com
Anchor Designer"I"
Version 2.6.6794.70
Company:
I Date:
11211612019
Engineer:
Page:
14/5
Project:
Address:
Phone:
E-mail:
3. Resulting Anchor Forces
Anchor Tension load, Shear load x, Shear load y, Shear load combined,
NVII (lb) V..� (lb) Vtlay (lb) %'(VUaX)'+(Vuay )2 (lb)
1 1341.0 0.0 0.0 0.0
Sum 1341.0 U 0.0 0.0
Maximum concrete compression strain (%.): 0.00
Maximum concrete compression stress (psi): 0
Resultant tension force (lb): 1341
Resultant compression force (lb): 0
Eccentricity of resultant tension forces in x-axis, e'W (inch): 0.00
Eccentricity of resultant tension forces in y-axis, e'Ny (inch): 0.00
4. Steel Strength of Anchor in Tension (Sec. D.5.11)
N�. (lb) 0 ON,� (I b)
13100 0,75 9825
5. Concrete Breakout Strength of Anchor in Tension (See, D.5.2)
Nb = k�)..�fk,'-s (Eq. D-6)
kc 23 fc (psi) hf (in) Nb (lb)
24.0 1.00 2500 4.000 9600
ONCb = 0 (Amcl&w)�'ed.NY'�,NY'�P,NNb (Sec. D.4.1 & Eq. D-3)
ANc (in') Am. (in 2) ca.min (in) VedN V'C'N �"P.N Nb (113) 0 Okb (I b)
82.50 144.00 3.00 0.850 1.25 1.000 9600 0.70 4091
6. Pullout Strength of Anchor in Tension (Sec. D.5
Qj
ONpn = O'Pc.PNP = OPcAA&gr� (Sec. D.4.1, Eq. D-13 & D-14)
WC'P Awy (W) f� (psi) 0 ONpn (I b)
1.4 2.10 2500 0.70 41121
Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility.
5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com
Anchor Designer TM
Version 2.6.6794.70
Company:,
::��
12/1612019
Engineer:
I Page:
15/5
Project:
Address:
Phone:
rE-mWil:
11. Results
11. Interaction of Tensile and Shear Forces (Sec. D.7)?
Tension
Factored Load, Ni,. (lb)
Design Strength, oN. (lb)
Ratio
Status
Steel
1341
9825
0.14
Pass
Concrete breakout
1341
4091
0,33
Pass (Governs)
Pullout
1341
41121
0.03
Pass
PABS (518"0) with hef = 4.000 Inch meets the selected design criteria,
12. Warnings
- Minimum spacing and edge distance requirement of 6da perACI 318 Sections D.8.1 and D.8.2 for torqued cast -in -place anchor is waived per
designer option.
- Designer must exercise own judgement to determine if this design is suitable.
Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility.
�;-,il 5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.stronglie.Gom
Anchor Designer TM
. . . . . . . . . . . . .
Software
Version 2.6.6794.71
I.Proiect Information
Customer company:
Customer contact name:
Customer e-mail:
Comment:
Company:
I Date:
112/16/2019
Engineer:
Page:
11/5
Project:
Address:
Phone:
Project description: HDU2 Cast in
Location:
Fastening description:
2. Input Data & Anchor Parameters
General
Base Material
Design method:ACI 318-11
Concrete: Normal -weight
Units: Imperial units
Concrete thickness, h (inch): 24.00
State: Uncracked
Anchor Information:
Compressive strength, f. (psi): 2500
Anchor type: Bonded anchor
4),:,v: 1.0
Material: F1 554 Grade 36
Reinforcement condition: B tension, 8 shear
Diameter (inch): 0.625
Supplemental reinforcement: No
Effective Embedment depth, he (inch): 5.000
Reinforcement provided at comers: No
Code report: ]CC -ES ESR-2508
Ignore concrete breakout in tension: No
Anchor category- -
Ignore concrete breakout in shear: No
Anchor ductility: Yes
Hole condition: Dry concrete
h�tn (inch): 8.13
Inspection: Continuous
c., (inch): 7.58
Temperature range, Short/Long: 11Of75*F
C.i. (inch): 1.75
Ignore 6do requirement: Not applicable
Smin (inch): 3.00
Build-up grout pad: No
Recommended Anchor
Anchor Name: SET-XPO - SET-XP W/ 5/8"0 F1 554 Gr. 36
Code Report: ICC-ES ESR-2508
___ - --------- ------- .. .. ... ...... ..
Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility.
3,mmscn Strcng-T'I'a icnnpav� inc 5956 W. Las Posilas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www. strong fie.com
Anchor Designer"m
M, 21, R Software
M I I r,
Version 2.6.6794.71
Load and Geometry
Load factor source: AGI 318 Section 9.2
Load combination: not set
Seismic design. No
Anchors subjected to sustained tension: No
Apply entire shear load at front row: No
Anchors only resisting wind and/or seismic loads: No
Strength level loads:
N.. [lb]: 1341
V.. [1b]: 0
Vuay [lb]: 0
<Figure 1> z
0 1b
Company:
I Date:
112/1612019
Engineer:
Page:
12/5
Project:
Address:
Phone:
E-mail:
1341 1b
I
3.00
3.00 4%%Z4410' Olb
Y
24.00
Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility.
Siroro-Tze Ccm-pan-i 5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com
Anchor DesignerTM
Software
Mjn�g, Version 2.6.6794.71
<Figure 2>
Company:
I Date:
112/16/2019
Engineer:
I Page:
1315
Project:
Address:
Phone:
[—E-m—ail-1
Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility.
smn'.4'w 5z'C'f-'j- T:e �nn 5956 W. Las Posilas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com
jW"'M611190 Anchor DesignerTm
[1111�tl' 7
Software
Version 2.6.6794.71
Company:
�16/20119
Engineer:
I Page:
1415
Project:
Address:
Phone:
FE-m�il:
3. Resulting Anchor Forces
Anchor Tension load, Shear load x, Shear load y, Shear load combined,
N.� (lb) Wax (lb) V.8y (lb) N1(V..�)1+(V..y)1 (lb)
1 1341.0 0.0 0.0 0.0
Sum 1341.0 0.0 0.0 0.0
Maximum concrete compression strain (%.): 0.00
Maximum concrete compression stress (psi): 0
Resultant tension force (lb): 1341
Resultant compression force (lb): 0
Eccentricity of resultant tension forces in x-axis, e'W (inch): 0.00
Eccentricity of resultant tension forces in y-axis, Wny (inch): 0.00
4. Steel Strength of Anchor in Tension (Sec. D.5.1)
N�� (lb) 0 ^. (lb)
13110 0.75 9833
5. Concrete Breakout Strenalth of Anchor In Tension (Sec. D.5.2
Nb = W..-,If.he 1-6 (Eq. D-6)
kc fc (psi) h.f (in)
Nb (lb)
24,0 1.00 2500 5.000
13416
ONCb = 0 (AN�lAtico)'Peo,.NVI,.mYIcp,NNb (Sec. D.4.1 & Eq. D-3)
AN� (in') An- (in2) c...,-� (in) YD d, N
V"C' N Nb (lb) 0 ^b (lb)
90.00 225.00 3.00 0.820
1.00 0.989 13416 0.65 2830
6. Adhesive Strength of Anchor in Tension (Sec. D.5.5)
� MoActfshoa-lo-Ksat
(psi) f3hod-tem Ksat rkuur (psi)
2046 1.00 1.00 2046
Nt. )L.r.w;rd.h.t (Eq. D-22)
).a -r-c' (psi) d. (in) h.f (in) Nb� (lb)
1.00 2046 0.63 5.000 20087
ON. = 0 (AunlAivao)Y'adwa TcpN*Nft (Sec. DA.1 & Eq. D-18)
Aiv. (in 2) Amo (in 2) cNa (in) c.,�m (in) V'QdN8 VCP.N. Nb. (lb) 0 ON. (lb)
102.29 290.63 8.52 3.00 0.806 1,000 20087 0.65 3702
Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility.
5956 W. Las Positas Boulevard Pleasanton, CA94588 Phone: 925.560.9000 Fax:925.847.3871 www.stronglie.coin
U
Anchor Designer"m
I 1�1� �LVI�'ll,�,,�l",�,�,�ll,�-""\�,,'\\�\",\,-\%X�',
Software
Version 2.6.6794.71
2,
01" �1-1
QD
Company:
12/16/2019
Engineer:
Page:
15/5
Project:
Address:
Phone:
E-mail:
11. Results
11. Interaction of Tensile and Shear Forces (Sec. D.71?
Tension
Factored Load, N., (lb)
Design Strength, oN� (lb)
Ratio
Status
Steel
1341
9833
0.14
Pass
Concrete breakout
1341
2830
0.47
Pass (Governs)
Adhesive
1341
3702
0.36
Pass
SET-XP wl 518"0 F1554 Gr. 36 with hef = 5.000 Inch meets the selected design criteria.
12. Warnings
- When cracked concrete is selected, concrete compressive strength used in concrete breakout strength in tension, adhesive strength in tension
and concrete pryout strength in shear for SET-XP adhesive anchor is limited to 2,500 psi per ICC-ES ESR-2508 Section 5.3.
- This temperature range is currently outside the scope of ACI 318-14/-1 1 and ACI 355.4. Designer must exercise judgement to determine if this
design is suitable.
- Minimum spacing and edge distance requirement of 6da per ACI 318 Sections 13.8,11 and D.8.2 for torqued cast -in -place anchor is waived per
designer option.
Designer must exercise own judgement to determine if this design is suitable.
Refer to manufacturer's product literature for hole cleaning and installation instructions.
Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility.
5956 W, Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 wwwr.strongtie.com
- - SS - - - SS - - - SS - - - SS �_ - - S
-- - - - - - - - - - 6&7 -- - - - - - - - - - --- - - -
W_W_W_W
EX CUR13/GUTTEP EX CUPD �LIT
FH
_1
IL
YARD
31 r L - -
-EX PEG
0
0
EX PEC
SITE PLAN
SCALE, I- =ICO
EX
WATER
EX DRIVEWAY
EX
SS __ - - SS - - - SS
-------------
vv - ___ vv - W
-H ST. S.W.
N89o34'25"W PL=140.00
---------------
EX C MNE
_r HI Y
7TH ST SW
EXISTING S.F.R.
INTERIOR REMODEL
114 SF APP1I`ION
EXISTING, CONCRETE PATIO ON GRAPE
DEC ECX, PEC 0-1 FX Ex DEC EX
QEC
N89 3'54"W'' L-I
IMPERVIOUS SURFACE
EXISTING HOUSE & POPE
1,590.5 5F
EXISTING DRIVEWAY & APRON
5�7 2 SF
EXISTING CONCRETE rA11O ON GRAPE
973.5 SF
EXISTING UW"ERFP WALKWAY
5.7 SF
EXISTING SHED & ROOF
239.9 5F
TOTAL EXISTING IMPERVIOUS SURFACE:
5,67b.v bt-
PPOP05EP NEW ADDITION & ROOF
135.3 SF
TOTAL NEW & PEPLACEP IMPERVIOUS SURFACE:
135.3 SF
TOTAL PROPOSED EX & NEW IMPERVIOUS SURFACE:
3812.1 SF
I
DATUM POINT (91) EX15TING :2 1
SIDE SEWER MA"40LE - 7�
S - - - Ss - - - SS _. - _i_
-- - - - - - - - - - - - - - - s
W I W-w
k N'
- - - - - - - - - - - - -
p
'i9E
ADDITION
(114 5F)
U ca
r YARD
RO OSEP FRONT YARD
0 APPITION
z 3:
EX 5HEP
DEMO OR RELOCATE
EXISTING WOOD FENCE.
OWNERTOCONFIFM
I?
LOT COVERAGE
EXISTING HOUSE/GAFAGE
1.565 SF
EXISTING 5HEP
1&2 SF
EXISTING COVERED POPCH
68 SF
TOTAL EXISTING LOT COVERAGE:
1,818 5F
PROPOSED NEW ADDITION
+114 SF
!�AL,F,ROFOSED LOT COVERAGE:
1932 5F
I ALLOW LOT COVERAGE:
9=2 5F X 35% = 3,354.2 5F OK
OWNER/CONTRACTOR IS RESPONSIBLE
FOR EROSION CONTROL AND DRAINAGE
OWNERICONTRACTOR RESPONSIBLE
FOR LOCATING ALL ON -SITE UTILITIES.
RELOCArION/RE%ASION TO ANY UTILITIES
MAY REQUIRE SEPARATE PERMIT
,I =r�oaw/r
a 'I �1808 elI cf..�.
penri W
A6 BUIL I - MAIN FLOOR
5CALE 1/8 - 1 0 (b
AVERAGE GRADE
CORNER POINT
I ELEVATION
A J±294'
13
4315
C
431.5'
AVERAGE GFAOE
429.,V
= 4W.6
MAX HEIGHT = 4555
EXHE,1GH1 = 443.7 OK
(, AIGE PFOPOSEP)
Uj
`0
T11
N
Zone�
&-� Corner)� -la&,
Setbacks Required Actual
- 131
Front
Sides
Rear
Other
Height
GENERALNOTES
PROJECT INFORMATION
THESE DRAWINGS ARE THE PROPERTY OF H2P, ULG. ANY REPRODUCTIONS MUST BE AUTHORIZED BY THE ARCHITECT AND MUST BEAR THE
PROJECT OWNER ERIC AND ALICIA HALL
NAME OF THE ARCHITECT. 91 COPYRIGHT 2019 BY H2P. LLC. THESE DRAWINGS ARE PROTECTED SY FEDEM AND STATE COPYRIGHT
8002 217TH 5T 5W
LAWS.
EPMONDS WA 98026
1*
-CONSTRUCTION To CONFORM TO THE 2015 INTERNATIONAL RESIDENTIAL CODE (IPC)L WASHINGTON STATE LAWS AND FEGULATON5,
PROJECT APOHITECT- HEIPI HELGESON
CURRENT WASHINGTON STATE PE51PENTIAL ENERGY CODE AND VARIOUS CODES IMPOSED BY LOCAL AUTHORME5.
PROJECT DESIGNER: USA M0NrALYO
-A SEPARATE PERMIT MAY DE REQUIRED FOP, PLUMBING, ELECTRICAL. AND/OP MECHANICAL WORK AS APPLICABLE
H2D ARCHITECTURE , PESIGN
-A COPY OF THE APPROVED PERMIT PLANS MUST DE ON THE JOB SITE DURING CONSTRUCTION.
23020 EDMONDS WAY. #113
2. -ONSIBILITY,
EDMONDS. WA 9SO20
_FRIOR TO CONSTRUCTION, THE CONTRA is ro VERIFY ALL P1MEN5TON5 AND STRUCTURAL MEMDER SIZES.
-PO NOT SCALE COMACT DOCUMENTS.
STRUCTUPAL ENGINEER: 7OPP FISHER. P.E_
4F ANY DISCREPANCIES IN THE DRAWINGS OR FROM THE CODES ARE NOTED. ARCHITECT 15 TO BE NOTIFIED IMMEDIATELY.
HARRIOTTVALENTINF ENGINEERS. INC.
-ALL CHANGES MADE BY THE CONTRACTOR SHALL 13E SUBMITTED IN WRMHG TO THE ARCHITECT AND STRUCTURAL ENGINEER FOR
1932 FIRST AVENJE, SUITE 720
APPROVAL PRIOR TO CONSTRUCTION
5EArftF- WA 95101
_THE ARCHITECT SHALL NOT HAVE CONTROL OR CHARGE OF, AND SHALL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS AND METHODS.
206-624-4760
SAFETY PRECAUTIONS, ACTS OR OMISSIONS OR PERFORMANCE OF IHE CONTRACTOR.
_CONTRACTOR SHALL BE PE5FONS1DUE FOR THE PERFORMANCE AND WEATHERPROOFING OF 11E ENTIFE BUILDING, ITS COMPONEN r
EQUIPMENT, AND PARTS.
PROJECT DESCRIPTION,
-ALL STRUCTURAL 5Y5TEM5 SUCH AS WOOD TRU55ES WHICH APE TO 13E COMP05EP OF COMPONENTS TO SE FIELD ERECTED SHALL BE
SUPERVISED DY THE SUPPLIER DUPING MANUFACTURING, DELIVERY, HANDLING. STORAGE. AND ERFICTION IN ACCORDANCE WITH
PROJECT ADDRESS:
INSTRUCTIONS PREPARED SY THE SUFFLER.
-ALL WORK MUST FOLLOW CURRENr RPP RULES AND REQUIREMENTS AS DEFINED DY THE EPA AND THE STATE OF WASHINGTON.
-ALL WASTE AND REFUSE CAUSED IN CONNECTION WITH THE WORK SHALL BE REN40VEP FROM THE PREMISES AND DISPOSED OF BY THE
TAX LOT NUMSER: 00602600002000
OONTPACTOF. THE PREM15ES SHALL DE LEFT CLEAR AND CLEAN TO THE SATISFACTION OF THE OWNER.
-CONIRACTCR SHALL DESIGN AND INSTALL SHORING AS REQUIRED TO PERFORM WORK. ENGINEERING, CONSTRUCTION AND SAFETY OF
LEGAL DESCRIPTION. rYUEP5 TRACTS SILK 000 P-00 LOT 20
THE 5HOPING SHALL DE THE RESPONSIBILITY OF THE CONTRACTOR.
3. SOILS'
-FOUNDATION PE51GN 15 BASED ON AN ASSUMED AVERAGE 59L DEARING OF 2,000 PSF OR PER GEOTECHNICAL REPORT. ALL FOI
SHALL BE CAST ON UNDISTURBED FIRM NATURAL 5OIL OR COMPACTED SOIL OF 2,000 P5F DEARING CAPACITY AT LEAST T-6 DELOW
LAND USE CODE COMPLIANCE STATISTICS
LOWEST APJACENf GRADE, AND FREE OF ORGANIC MATERIALS. FOOTING EXCAVATION SHALL DE FREE OF LOOSE SOILS, PEDFIS, AND
FREE WATER AT ALL TIME5. THIS OFFICE TAKES NO RE5PONSIDIL[TY IN VERIFYING THE ACCURACY OF ENGNEERING DATA SUPPLIED DY
ZONE: R55
OTHERS.
4. ATTIC REQUIREMENTS,
-APPLY ROOFING IN AOCI WITH IRC CHAPTER 9. PROVIDE ATTIC VENTILATION AS INDICATED ON DRAWINGS AND As OUTLINED IN IRC
LOT COVERAGE- LOT ARE& 9555.2 BE
5EC R506.
EXISTING HOUI 1565 5F
-THE NET FREE VENTILATING AREA SHALL BE NOT LESS THAN V150 OF THE AREA OF THE SPACE VENTILATED. EXCEPT THAT THE AREA MAY
EXISTING SHED. 182 SF
EX15TM COVERED PORCH:
13E 11300 PROVIDED AT LEAST 50 PERCENT OF THE REQUIREDVENTILATING, AREA 15 PROVIDED BY VENTILATION LOCATED IN THE UrPER
66 SIF
TOTAL E451ING LOT COVERAGE. 1,818 BE
PORTION OF THE SPACE TO BE VENTILATED AT LEAST 3 FEET A13OVE EAVE OF CORNICE VENTS WITH THE DALAICE OF THE REQUIRED
NEW ADPITIOR 679.5 5F
VE�MLATIONFROVIPED15YEAVEORCMt4CEVENT5. QRC5ECR&OD�
TOTAL PROP05EP LOT COVERAGE 2497.5 SF
-ATTIC ACCESS. MINIMUM 22" x W'WITH MINIMUM W'HEADROOK UNOVI5TFUCTEP, READILY ACCESSIDUE OPENING. ]PC SEC R507.
ALLOWED LOT COVERAGE-- 95b52 5F X 357. 3554.2 5F.. OK
ACCESS DOORS SHALL BE WEATHEFSTRIFFEP AND INSULATED TO A LEVEL EQUIVALENT TO THE INSULATION ON THE SUPROUNPIN3
SURFACES.
RE7P SETBACK FRONT-. 25
4N ROOMS NOT rPOVIDEP WITH AN OPERABLE WINDOW OF 1.5 50, FT. OR GREATER. A MECHANICAL VENTILATION SYSTEM CAPABLE OF
REAR SETBACK: 15,
PROVIDING 5 AIR CHANGES PER HOUR SHALL BE PROVIDED.
51M SETSACK_-
-VENT DRYER, SATH FANS, AND RANGESIOVEN5 TO THE OUTSIDE
AM
_VENr FANS SHALL TERMINATE Af THE EXTERIOR OF THE BUILDING, PER IFIC SECTION Mism.3 AND Iw5EcnON 50m
FARKI 2 GARAGE PARKING SPACES
-INSULATE ALL DUCTS OUr5IDE OF CONPITONED SPACE PER WA STATE ENERGY CODE.
PLAMS
-KITCHEN RANGE HOODS: RANGE HOOPS CAPADLE OF EXI M51ING MORE THAN 400 GEM RWUIRE MAKE-UP AIR PER TRIP M1503.4.
BUILDING 15UILDING HEIGHT LIMIT = 2EY
6. GLAZING:
INFOR REFER TO SHEET A2D AND Ap 1 bErAILEP
FOR
_To DE IN COMPLIANCE WITH IRC 5EC RsOb AND WASHINGTON STATE SAFE rY GLASS LAW. EXCEPTIONS ARE AS OUTLINED IN IRC SEC
HEIr Hr INFORMA11ON
Rw&.
01v
-GLAZING IN LOCATIONS SUBJECT TO HUMAN IMPACT SUCH AS GLASS IN POCIRS. GLAZING WITHIN 2WON EITHER SIDE OF A POOR
OPENING, GLAZING CLOSER THAN W TO A FLOOR, SHOWER DOORS AND TUB ENCLOSURES 5RALL BE WIRE REINFORCED. TEMPERED
ENERGY CREDIT INFORMATION Jo�
GLASS. LAMINATED SAFETY GLA55 OR 5RATTER RESISTANI" PLASTIC.
-5UPING, GLA55 POOI TO BE SAFETY GLAZNG. LAMINA rEP OR TEMPERED GLA5s.
ENERGY CREDIT FROM WASHINGTON STATE ENERGY CODE TABLE 4062
-SHOWER ENCLOSURES SHALL BE APFROVEP WIRE REINFORCED. TEMPERED OR LAMINATED SAFETY GLA55 OR SHATTER RESISTANT
SMALL DWELLING UNIT: ADDITIONS TO EXISTING, DUILDINS, GREATER THAN 5005F OF
FLASTIC.
Ap
HEATED FLOOR 'EA DUT LESS THAN 15005F = 1.5 CREDITS
-GLAZW, WITHIN 18" OF FLOOR AND GREATER THAN II LEAST PiMENSION SHALL COMPLY WITH IMPACT LOADS. SEE PLANS.
-ALL EXTERIOR WALL GLAZING SHALL BE POJEILE GLAZER UNLESS NOTED OTFEIZVV15F AND COMPLY WITH STATE OF WASHINGTON
ENERGY COPE.
5a EFFICIENT R 1EA ' .5 5
ALL UWWAN' P KlTr"MHEO. 51 L USE SHALL BE
RATED AT M. GP OR LESS. ALL rHER
-EGRESS IN EVERY SLEEPING ROOM SHALL HAVE A MINIMUM NET CLEAR OPENING OF 5-7 SOL Fr. THE MINIMUM NET CLEAR OPENING
HEIG1T DIMENSION SHALL 13E 24�'. M114MUM NET CLEAR OPENING WIDTH OF 20'ANP A FINISHED 511-1- HEIGHT NOT MORE THAN 4#'ADOVE
A ATED AT
10 GrM OR LESS.M
THE FLOOR. IRC SEC P310.
7. ENERGY,
51; EFFICIENT WATER HEMINS.-I. OR
GAS. PROFANE, OF OIL WATER
-ALL MATERIALS. WORKMANSHIP AND CON15TRUCTION SHALL CONFORM TO IRC REQUIREMENTS AND THE WASHIWTON STATE ENERGY
.91
AL 15CFEDT1`5
CODE, LATEST EDITOR VERIFY ALL CONDITIONS BEFORE PROCEEDING WITH WORK
CO
MPLIANC,-
-APPLICATION AND INSTALLATIONS OF INSULATION AND VAPOR DAPPIER5 SHALL COMPLY WITH STATE OF WASHINGTON THERMAL
INSULATION STANDARDS.
BUILDING, AIR LEAKAGE TESTING, FER 5EC 502.4.5. 15 REQUIRED FPM TO FINAL INSPECTOR THE TEST RESULTS SHALL 13E POSTED ON
THE PE51PENVAL ENERGY COMPL ANCE CERTIFICATE
I/
-EACH DWELLING UNT 15 TO HAVE ONE PROGRAMMABLE THEPM05TAT FOR REGULATION OF TEMPERATURE PER SEC 503,51
-A SIGNED AFFAIDAVIT DOCUMENTING THE DUCT LEAKAGE TEST RESULTS SMALL BE PROVIDED TO THE DUIUPTNG INSPECTOR PRIOR TO AN
APPROVED FINAL INSPECTION,
-PUCT LEAKAGE TEST RESULTS SHALL BE PROVIDED TO THE BUILDING INSPECTOR AND HOMEOWNER PRIOR TO AN APPROVED FINAL
INSPECTION
_M[NIMUM 75% OF PERMANENTLY INSTALLED LAMPS IN LIGHTING FIXTUFE5 SHALL BE HIGH EFFICACY LAMPS PER SEC 404.1.
-WHERE THE PRIMARY HEATTNG SYSTEM 15 A FORCEP-AlR FURNACE AT LEAST ONE THERMOSTAT PER PWELUw, UNIT 5FIALL DE CAPABLE
OF CONTROLLING THE HEATING AND COOLING SYSTEM ON A DAILY SCHEDULE TO MAINTAIN DIFFERENT TEMPERATURE SET POINTS AT
DIFFERENT TIMES OF THE DAY THE THERM05TAT SHALL ALLOW F0. AT A MINIMUM. A 5-2 PROGRAMMABLE SCHEPULE
(WEEKPAY5/WEEKENP5) AND BE CAFA13LE OF rROVIDT1,13 AT LEAST TWO PROGRAMMABLE SETBACKS PER DAY.
8. STAIRS,
-MINIMUM HEADROOM 6-6' . MINIMUM TREAD ICY' . MAXIMUM R15EFZ 7 31,V'
-HANDRAIL: REQUIRED AT ALL STAIRS WITH MORE THAN 4 PISERS PER IRC 511.7.8. MINIMUM 5V AND MAXIMUM 35"ADOVE TREAD NOSING.
OPEN SIPES OF STAIRS MORE THAN W'ADOVE ADJACENT FLOOR SHALL HAVE HANDRAILS AND GUARDRAILS. HANDRAIL TO 13E I tf#�2"
CRL65 SECTIONAL DIMENSION AND 1 V2"AWAY FROM WALL.
-GUARPRAIL: SHALL SE MIN 36'iN HEIGHT WHERE APJACENr SURFACE OR GRAPE 15 30"OK MORE BELOW. RAILINGS $HALL BE 5PACEP
--_j
PRESCRIPTIVE REQUIREMENTS - ALLCUMATFZON . ES
LOCATION
R-VALUE
LLFACTOR
FENESTRATION U-FACTOK
WA
0.50
SKYLIGHT U-FACTOR
NIA
Ow
GLAZED FENESTRATION SHGC
WA
NIA
CEILING
49
OD26
WOOD FRAME WALL
21 INT
0.056
MA55 WALL R-YALUE
21/21
0,051.
FLOOR
w/w
OD29
13ELOW GRADE WALL
VI INT T13
OD42
SLA13 R-VAUUE AND DEPTH 1
10, 2 FT EN91NEERING
DIM
TO NOT ALLOW TIE PA55AGE OF A 4"5PHEFE PER TRC,3121
E�
-INSTALL FIRE BLOCKING AT MID-STPINGER SPAN AND AT WALL ALIGN STRINGER.
SHEET
INDEX
-COVER WALLS AND SOFFITS OF USA15LE SPACE UNDER STAIR WITH 518P TYPE `X'0YrSUM WALU3OA?P.
9.
01
PROJECT INFORMATTOR VIC1"TY MAP. GENERAL NOTES. AS-13UILT PLANS,
-INSULATION TO MEET THE CURRENT WASHINGTON STATE ENERGY COPE REQTS FOR TABLE K40211. TABLE R40213 AND SECTION R402.
SITE PLAN
REFER TO PRESCRIPTIVE TABLE ON SHEET OIL
02
C5W?pP
-EXISTING WALLS THAT APE OPENED DURING, A FEMOPEL TO BE INSULATED WITH P-21 BATT (FOR 2X6 WALIS) AND F-15 HIGH DENSITY
AID
DEMOLITION PLAN MAIN FLOOR
5ATT (FOR 20 WALLS) UNLESS NOTED OTHERWISF_
All
MAIN FLLOOR PLAN
EDMONDS
-WALLS TO BE INSULATED WITH MINMUM P-21 INSULATION BELOW GRADE WALLS TO BE INSULATED WITH MINIMUM R-21 INI
At2
AI,3
ROOF N
P At
WINDOW AND POOP, 5OHEPUUE
BUILD N� DEPARTMENT
ALLOW FOR TI-ERMAL BREAK BETWEEN FLOOR SLAD AND DASEMENT WALL UNLESS NOTED OTHERWISE
A910
EXTER OR ELEVATIONS
OR
WORK
-ROOF AND CEILING INSULATED WITH P-49 DLOWNTN AT FLAT CEILINGS AND K-35 HP. BATT AT VAULTED AREAS UNLESS NOTED
A2.1
EXTERIOR ELEVATION
ADDR S 0
OTHERWISE.
-ROOF: ALLOW FOR A MINIMUM V CLEAR BETWEEN TOP OF INSULATION AND 130TTOM OF SHEATHING FOR VENTING UNLESS NOTED
A3.0
A4.0
BUILDING SECTIONS A5NP WALL
TYR. DETAILS
OTHERWISE
SID
GENERAL STRUCTURAL NOTE
-VENTING 15 REQUIRED IN EACH J015T SPACE WHERE CONTINUOUS VENIING WITH A J015T SPACE 15 INTERRUPTED BY A HEADER (FOR
EXAMPLE ATA SKYLIGHT OR PROVIDE
52D
FOUNDA71ON PLAN
APPR DIVED DAT
HIP ). (2)111 VENTING, HOLES AT THE TOPOF THE RAFTER AT 11-E HEADER TO ALLOW FOR
CONTINUOUS THRU-VENIING INTO THE NEXT JOIST SPACE UNLESS NOTED OTHERWISE
52J
53-0
POPE FRAMING PLAN
STRUCTURAL PErAILS
0
B DG OFFICIAL.�
-FLOORS: INSULATED WITH P-30 DATT INSLXATION OVER UWEATEP SPACE UNLESS NOTED OTHERWISE
54.0
STRUCTURAL DETAILS
-51AB-ONGRAPE: PROVIDE EXTRUDED RIGID CL05EP CELL P-10 INSULATIOR INSULATION TO PROVIDE THERMAL BREAK DETWEEN 5LA13
PERIWIT
AND FOOTING AND RUN FROM THE TOP OF THE SLAB TO THE DOTTOM OF THE FOI INSULATION MAY SE INTERRUPTED FOP &EVERY
2'-O'TO ALLOW FOP DOWELING TO TIE SILAS AND FOOTING
VE PLmm G
NUMBER
TOGETHER. UNLESS NOTED OTHERWISE
III.. LG_E
RIP
i
00
"s IIT�MON:
,p THE GARAGE 51PE 5/6"TYREW GWD WHERE THERE 15 LIVING SPACE ABOVE. SUPPORTING COLUMNS, WALLS
AND BEAMS USE II PER IRC F302.6
_OPENING5 INTO A GARAGE: OPENING5 INTO A GARAGE SHALL HAVE A 50LID WOOD OR HONEYCOMD-CORE STEEL POOR NOT LF55 THAN
1-3/6 THICK, OR 20-MINLJTE FIRE RATING. DOORS SHALL BE EQUIPPED WITH A SELF-CLOI DEVICE PER IRC F,302.al.
11. VAPOR BARRIERS�
-AN AFFROVED VAPOR RARRIER SHALL 13E INSTALLED AT EXT EFIOF WALL5 AND AT ALL POPE PECKS. 13ELON ENCLOSED JOIST SFACE5
WHERE CEILING FINISHE5 ARE DIRECTLY INSTALLED TO JOISTS, AND ANY OTHER WALL OF, CEILING, SURFACES WHICH RECEIVE INSULATION
THIS VAPOR DARMER MAY BE A COMPONENT OF THE INSULATION MATERIAL AFFLICA11ON AND INSTALLATIONS OF INSULATION AND VAFOP
BARRIERS SHALL COMPLY WITH STATE OF WA5HINGTON THERMAL INSULATION STANDARDS.
12. FIRE SAFETY'
-SMOKE ALARM51PETECrOR5 (SP.): SMOKE ALARM51PETECTOR5 SHALL 13E INSTALLED IN ALL SLEEPING ROOMS. IN THE AREA OUTSIDE
THE SLEEPING ROOM AND IN OTHER LOCATIONS PER IRC R314. POWER 50UPCE AND INrEpCONNECIION PER IRC.
-CARBON MONOXIPE PETECTOR5 (C.MP.): SHALL HAVE AN APPROVED CAPDON MONCXIPE ALARM INSTALLED OUTSIDE OF EACH SLEEPING
AREA IN DWELLING UNTS AND IN EACH LEVEL IN ACCORDANCE WITH THE MANUFACTURERS REQUIREMENTS PEP IRC,315. SINGLE STATION
CARBON MONOXIDE ALARMS SHALL BE LISTED AS COMPLYINC, WITH UL2034 AND SHALL DE INSTALLED IN ACCORDANCE WITH THIS COPE.
WFA 720-2012 AND THE MANUFACTURERS INSTALLATION INSTRUCTIONS.
-CARBON MONOXIDE PE IIECTION SYSTEMS PER IRC 5152 THAT RCLUPE CAR" MONOXIDE PETECTOP5 AMP AUP113LE NOTIFICATION
APPLIANCES, INSTALLED AND MAINTAINED IN ACOORDANCE WITH TH15 SECTION FOP, CAFE30N MONOXIDE ALARMS AN) NFPA 720-2012.
SHALL BE PERMITTED. THE CARBON MONOXIDE DETECTORS SRALL BE LISTED AS COMPLYING WITH UL 2075. WHERE A HOUSEHOLD
CARBON MONOXIDE DETECTION SYSTEM 13 INSTALLED, IT SHALL BECOME A PERMANENr FIXTURE OF THE OCCUPANCY.
13. -CERTIFICATE &Tg
- A FERMANENT CEFTIFECATVSHALL BE COMPLETED AND POSTED ON OR WITHIN THREE FEET OF THE ELECTRICAL P15TRIRMON PANEL DY
THE BUILDER OR REGISTERED DESIGN PROFESSIONAL THE CERnFICATE SHAI.L RE COMPLETED BY THE DUILPER OR PSGISTEPEP DESIGN
PROFESSIONAL AND SMALL NOT COVER OR 0551 THE VISIBILITY OF THE CIRCUIT DIRECTORY LABEL, SERVICE DISCONNECT LASEL OR
OTHER REQUIRED LABELS. THE CERTIFICATE SHALL LIST THE PREDOMINANT P-VAUUE5 OF INSULATION INSTALLED IN OR ON CEILING/POOF
[ION (SLAV. MLOW-GRADE WALL. ANPIOR FLOOR) AND PUCT 5 OUTSIDE CONDITIONED SPACES; LLFACTORS FOR
WALLEI, FOUNDA
FENESTRATION AND THE RESULTS FROM ANY FECIUIREP PUrT SYSTEM AND BUILDING ENVELOPE AIR LEAKAGE TESTING PONE ON THE
DUILOING. WHERE THERE 15 MORE IRAN ONE VALUE FOR EACH COMPOI THE CERTIFICATE SHALL L15T THE VALUE COVERING, THE
LARGEST AREA THE CERTRIFICATE SRALL LIST THE TYPES OF EFFICIENCIES OF HEATING. COOLING. AND SERVICE WATER
EQUIPMENT.
21.M- 51 W
Im ST SW
2 2MSTCW
SITE
2151H ST SW
clt
220M 5T 5W
Lij
0
z 3:
Uj U)
CID
N
0
00
CY)
U) I-
CD
00
m
z
0
_j 00
<
LU
VED
` USr 13LU"
IS Ire
REGISTERED
A A
RCHITECT
HEIDI MICHELLE HELGESON
SEOF WASHINGTON
FHO
H 2 D
A R C H I T E C T U R E
D E S I G N
23020 EDMONDSWAY, #113
EDMONDS, WA 98020
P. 206 . 542 . 3 7 34
ww.h2darchitects.com
DATE: 1/11/2019
REVISEP: 12/12/2019
PERMIT SET
PROJECT INFORMATION,
VICINITY MAP, GENERAL
NOTES, AS -BUILT PLANS
RESUB
DEC 19 2619
BUILD,..
0"",
�Z'ENT
NOS
- THE DUILDING OR DWELLING UNIT SHALL BE TESTED AND VERIFIED AS RAVING AN AIR LEAKAGE PATE OF NOT EXCEEDING 5 AIR CHANGES
PEP HOUR. TESTING SHALL 13E CONDUCTED WITH A BLOWER DOOR AT A PRESSURE OF 02 INCHES W.G. (50 PASCALS). WHERE PEWPED N
BY THE CODE OFFICIAL. TESTING SHAILL 13E CONDUCrEP BY AN APPROVED THIRD PARTY. A WRITTEN REPORT OF THE RESULTS OF THE
TEST SHALL BE 5IGNEP BY THE PARTY CONDUCTING TIE TEST AND PROVIDED TO THE COPE OFFICIAL TESTING SML BE PERFORMED AT VICINITY MAP (NTS)
ANY TIME AFTER CREATION OF ALL PENETRATIONS OF THE BUILDING, THERMAL EWELOFE. T 01
PUBLIC WORKS
DEPARTMENT
GRATE
—FILTER SOCK WITH
OVER FLOW HOLES
(TYP)
�CATCH BASIN
NOTES:
1. CON CTOR/DEVELOPER SHALL MAINTAIN
THjjRA
APPLICATION AT ALL TIMES DURING
CONSTRUCTION PERIOD.
2. ANY SEDIMENT IN CATCH WIN INSERT
SHALL BE REMOVED WHEN INSERT IS
ONE_THIRD FULL.
3. CITY INSPECTION REQUIRED ON ALL
EROSION CONTROL METHODS BEFORE
OTHER WORK CAN BEGIN.
TEMPORARY
SEDIMENT TRAP
FOR CATCH BASINS
APPROVED BY: R. ENGLISH
REVISION DATE
JANUARY 2018
IMPERVIOUS SURFACE
_9151ING
HOUSE & ROOF
1.890.5 SF
EXISTING ORWEVAY & APRON
567.2 SF
EX15TING CONCRETE PA'nO ON GRADE
97&5 SF
EXISTING UNCOVEFED WALKWAY
5.7 5F
EXISTING 5HED & ROOF
239,9 SF
TorALEX15TlNG-IMPEFVIOUtltl —KI-AUt:
3.676,5 SF
PROP05EP NEW APPITION & ROOF
+135.3 -SF
TOTAL NEW & REPLACED IMPERVIOUS SURFACE:
135.35171
TOTAL PPOP05EP EX & NEW IMPERVIOUS SURFACE:
W12.1 51`1
DATUM POINr 0 EXISTING
SS — — — ss — — — ss — SIPE SEWER MANHOLE
— — ss --7 ss — — — ss — — — SS — — — Ss ss — — — SS — — — SS —7
-- — - — - — - — - — C& — - — - — - — - — - — --- - — - — - — - — - — - — - — - — - — - — - — - — — - - — - — - — - — - — - — - — — -
W — W — IN — IN W W—W—W W I W—W
17TH ST. S.W. --*—PROTECT L OttrL 5 WITHIN
FrO N�S�TP TION PEP
OF #EP AIL EP-902
EX CURI31GUrrER EXCUP13CUT EX CURD/GLITTEP
p p WATE k :E
Kin METER N89*34�25"W PL=140.00
...................... ........... 0
---------------
EX C.O.T
F
Y 0
'E('..
C
STALL TREE PROTECTION
STOCKPILE TO BE COVERED < NCING (0 PPIPLINE PER
Y OF EDMONDS
WITHN24HOUPS 1� k
A mw PEQUIFEMENTS.TY? — :E
IONI 1 (/0 INSTALL SPLA5WLOC7K
(ED BASE OF NEW
IL
L — — — — —
EX DEC
0 WPEC) EX PEC
0
0
EX DEC
EX DPlYEWAY POWNSPOI
It
'u P.S. I FY('.OVF rnW IlrwAY �g EX P.S.
- - - - - - - - - - - -
0
8802 217TH ST SW
EX151ING 5.F.F
INTERIOR REMODEL
114 SIF ADDITION
AREA OF
I ADDITION
(114 5F)
Exl�� FX D.5
— — — I — — — — — — — — — — — -- —
EXISInNG CONCRETE PATIO ON GRAPE
EX PEC A EX PEC� (EX qEC
CONSTRUCTION STORMWATER POLLUTION PREVENTION PLAN
5ME: r = io
NOTES:
1. CONTRACTOR TO VERIFY ALL EXISlING UnLITY LOCATIONS PRIOR TO CON5TFUCTION.
2. CONSTRUCTION EROSION CONTROL MEASURES MUST 13E IN PLACE AND APPROVED 13Y EDMONDS PPP PRIOR TO ANY EARTH DISTURBANCE. SCHEPULE AN
INSPECTION APPOINTMENT FOP THIS ITEM�
3. NO SEDIMENT SHALL BE TRACKED ONTO PAYED STREET OR ROADWAYS. SEDIMENT SHALL BE REMOVED FROM TRUCKS ANP EQUIPMENT rFIOP TO
LEAVING THE CONSTRUCTION SITE. IN THE EYEW OF FAILURE OF THE CONSTRUCTION STORMINATER SYSTEM RESULTING IN SEDIMENT TRACKING ONTO
PAVEMENT, THE CONTRACTOR SHALL IMPLEMENT MEASURES IMMEDIATELY TO COWECT THE SITUATION. THE CONTRACTOR SHALL EMPLOY EMERGENCY
MEASURES TO REMOVE SEDIMENT FROM PAYED SURFACES AS NECESSARY. STREET SWEEPING SHALL BE CONSIDERED AN EMERGENCY MEASUKIE, AND
NOT A DA51C COMPONENT OF THE CON5TFUC-nON 5TOPMWATEF SYSTEM. SEDIMENT TRACKED ONTO PAYED SURFACES SHALL NOT BE WASHED INTO
STORM DRAINS OR OTHER INLETS.
4. INSTALL FILTER FENCE AS NECE55AFY TO CONTROL SEDIMENT AND PREVENT THE DISCHARGE OF POLLUTANTS.
5. AFTER CONSTRUCTION 15 COMPLETE, ALL EXP05EP EARTH SURFACES WILL BE LANDSCAPED WITH SUITABLE VEGETATION TO PREVENT ER05ION FOP THE
PEFMANENTCONDITION.
\ \ R:
E
DEMO OR RELOCATE
E TING WOOD FENCE,
AS
CONFIRM WITH OWNER
_j 'p
A
T,
�Tw
0
co:'
L
<
co
co
t0aw
� -0
ZE
w
Ti
T,
T,
N
C.0
04
z �: CD
00
LLI co or)
T_
P
U) U)
Lij
C4 z
0 0
00
00
< Lu
M
V 9716
REGIBIERED
C
:' I ]
ARCHITECT
HEU �.E- —
WATEOFWASHINGM3
-A'
H 2 D
A R C H I T E C T U R E
D E S I G N
23020 EDMONDSWAY, #113
EDMONDS, WA 98020
P. 206 . 542 . 3 7 34
www.h2darchitects.com
DATE: 1/1112019
REVISEP: 12/12/2019
PERMIT SET
CSWPPP & STANDARD
DETAILS
RESUB
DEC 19 2019
BUILDING DE RTMENT
CITYOF ErMONDS
02
MAIN FLOOR DEMO PLAN
51 V4' = T-7
= EXISTINCOWALLS
rl - I DEMO WALLS
WALL FOP NEW
NOTES.
1. VERIFY ALL SALVAGE ITEMS WITH OWNER PRIOR TO DEMOLITION
IN
w (o
C)
z 00
W U) cy)
7-
U) I-- U)
LU o
c-4 z
c) 0
00
00
< LLJ
r
j� �9716 REGISTERED
ARCHITECT
HEIDI MICHEUE HELGE ON
S—EOF MSHINGTON
2
-A
H 2 D
A R C H I T E C T U R E
D E S I G IN
23020 EDMONDSWAY, #113
EDMONDS, WA 98020
P. 2 0 6 . 5 4 2 . 3 7 3 4
www.h2darchitects.co.
DATE: 1/11/2019
FEVISED: 12/12/2019
PERMIT SET
DEMOLITION PLAN MAIN
FLOOR
RESUB
DEC 19 2019
BUIWINGDEPARTM NT
C" OF EDMONDS
A1.0
EX GAS WATER HEATER NOTES:
1. EXISTING GAS WATER HEATER TO REMAIN
2. VERIFY SHUTOFF VALVE 0 CONNECTION TO APPLIANCE.
3. PER [PC M1307.2 ANCI-IOF OR STRAP WATER HEATER
APPLIANCE TO RES15T HORIZONTAL P15FLACEMENT
CAUSED DY EARTHQUAKE MOTION. STRAPPING SHALL DE
AT POINTS WITHIN THE UPPER 1/3RD AND LOWER 1/3RP OF
THE APPLIANCUS VERTICAL DIMENSIONS. AT THE LOWER
POINT. THE STRAPPING SHALL MAINTAIN A MINIMUM
P15TANCE OF #'ADOVECONTPOLS.
EX FURNACE NOTES:
1. EXISTING GAS FURNACE TO REMAIN
2. VERIFY SHUTOFF VALVE 0 CONNECTION TO APPLIANCE
3. PER SVC r)07Z.5: WHOLE -HOUSE VENTILATION SYSTEM
INTEGRATED WITH THE FORCEP-AIR SYSTEM.
4. INTEGFATEP WHOLE HOUSE VENTILATION SYSTEM SHALL
OPERATE CONTINUOUSLY. PROVIDE CONTROLS TO ALLOW
OPERATION OF VENTILATION SYSTEM WITHOUT NEED TO
OPERATE HEATING SYSTEM. A LA13EL SHALL SE AFFIXED TO
THE CONTROLS THAT PEAPS'%HOLE HOUSE VENTILATION (SEE
OPERATION IN5TFUCVON5)".
5. PROVIDE CONTINUOUS WHOLE HOUSE MECHANICAL
VENTILATION AT A MINIMUM AIFFLOW RATE OF 45 CFMI. REFER
TO IFC TAKE M1507.3.3
VENTILATION REQUIREMENTS
VENTILATIONNOTE5:
WHOLE HOUSE VENTILATION TO DE INTEGRATED INTO THE FORCED
AIR SYSTEM TO MEETIRC M1507.3Z.
PROVIDE CONTINUOUS AIRFLOW OF 45 CFM.
MAIN FLOOR PLAN
5GALE: 1/#' = 1-0-
EMST7NGIVALL9
NEW WALLS
NOTES:
1. ALL DIMENSIONS APE GIVEN TO THE FACE OF STUD UND.
2. ALL POOR AND WINDOW DIMENSIONS ON THIS PLAN APE ROUGH OPENING SIZES, UNO. FEFEF TO WINDOW AND DOOR
SCHEDULE FOP MOPE INFOFMA-noN.
5. SEE ATTACHED WSEC FORMS FOR ENERGY COPE COMPLIANCE INFORMATION
4. INSTALL SWOKE DETECTORS (5.P.) AT LOCATIONS SHOWN. HARPWIPE AND INTERCONNECT DETECTORS TO POWER
SUPPLY AND PROVIDE DATTEKY 13ACKUP AS REQUIPEP.
5. INSTALL CARSON MONOXIDE ALARMS (C.M.P.) OUTSIDE EACH SEPARATE SLEEPING AREA IN T11E IMMEDIATE VICINITY OF
THE BEDROOMS. THE ALARM AND SHALL 13E LISTED AS COMPLYING WrrH UL 2034 AND SHALL DE INSTALLED IN
ACCORDANCE WITH SRC R315,3 AND THE MANUFACTURERS INSTALLATION MTPUCnON5
GROSS FLOOR AREA (MEASURED FROM INSIDE OF EXTERIOR WALLS)
EXISTING MAIN FLOOR AREA
961.7 S3F
NEW MAIN FLOOR ADDITION:
100 5F
S'
EX15TING UNCONDITIONED GARAGE:
455.4 5F
TOTAL CONDITIONED AREA
w (o
C) C\j
z (z)
co
W 0-)
0 T- <
P �:
U)
U)
z
c) 0
00
05
w
r
REGISTERED
ARCHITECT
" W ("I. I
HEIDI MICHE�E HELGESO
8TA�CFWASHINGMN
H 2 D
A R C H I T E C T U R E
D E S I G N
23020 EDMONDSWAY, #113
EDMONDS, WA 98020
P. 206 . 54 2 . 3 7 34
www.h2darchitects.com
DATE: 1/11/2019
REVISEP: 12/12/2019
N
PERMIT SET
MAIN FLOOR PLAN
RESUB
DEC 19 2019
BUILDNGDEPARTM Nr
CITYOFEDMONDS
A1.1
I------- ��: -V ---------------------
ROOF PLAN
SCALE-. 1/#' . T-0-
= EX15TM FOOF
pm�3 NEW ROOF
FX15TING SHEP FOOF
------- ------------------
EX151ING RIDGE
----------------------
t 2
A3.0
D
AZ5D
VENTILATION REQUIREMENTS Q EAST AMMON
ATTIC VEN11LATION NOTES:
TOTAL NET FREE VENTILATIW, AREA SHALL NOT DE LE55 THAN 1/150 OF THE
AREA OF THE SPACE VENTILATED EXCEPT THAT REDUCTION OF THE TOTAL TO
1/300 IS PEP MTI"TED PPOVIDED THAT AT LEAST 40 PEFCENT AND NOT MORE
THAN 50 PERCENT OF THE REQUIRED VENTILATING AREA 15 PROVIDED 13Y
VENTILATORS LOCATED IN THE UPPER PORTION OF THE SPACE TO 13E
VENTILATED AT LEAST ZY ADOVE THE EAVE VENTS Willi THE DALANCE OF THE
REQUIRED VENTILATION PROVIDED DY THE EAVE VENTS.
NEW TOTAL ATTIC AREA 0 SOUTHEAST = 99.4 5F
REQUIRED VENTILATION = 0.3 SF OR 47.6 SQ INCHES (23.6 SQ INCHES AT THE
EAVE, 24 SQ INCHES AT RIDGE)
PROVIDE ROOF RIDGE VENT AT NEW VAULTED CETLING = 24 INCHES MIN NFVA
PROVIDE CONTINUOUS SOFFIT VENT AT EAVES = 23.6 50 INCHES MIN
PROW DETAIL TO
MATCH EX15TING;
CONFIRM DIMENSIONS
IN THE FIELD
Ill (.0
C.) N
z 3: 0,
00
Lu U)
F—
U) r-
U)
c\I 0
c\I z
0 0
00
00
< w
r
1� LIS REGISTERED
ARCHITECT
" " /%'. I
HEIDI MICHELLE HELGE N
STATEOF WASHINGTON
H 2 D
A R C H I T E C T U R E
D E S I G N
23020 EDMONDSWAY, #113
EDMONDS. WA 98020
P. 206 . 542 . 3 7 34
www.h2darchitects.com
DATE: 1111/2019
FEVISEP: 12112/2019
PERMIT SET
ROOF PLAN
RESUB
DEC 19 2019
I D CE
3UILMC N S
C E&MMOTM N�
A1.2
DOOR SCHEDULE
ID
R.O. DIMENSIONS *SEE NOTE I
DOOR LEAF DIMENSIO
TYPE
THICK
AREA
(SF)
NOTES
WIDTH HEIGHT
W HT"
MAIN FLOOR
01
2�6'
6-11112"
24'
6-91,
SWING
U-1 316,
VERIFY ALIGN W/ EX HEAP HEIGHT
02
2�6'
6-11112"
24'
0-91,
POCKET
U-1 316,
VERIFY ALIGN W/ EX HEAD HEIGHT
03
9-2"
6-111/2"
PR 2--6'
1-9.
51-PASS
U-1 316,
VERIFY ALIGN W1 EX HEAP HEIGHT
04
2'-&'
6-11112"
2�6'
& -9.
'W,
SWIN(l
U-1 3/6,
VERIFY ALIGN W1 FX HEAD HEIGHT
05
Z-6'
6-111/2"
2-6'
& -9.
SWING
C
'W,
C-1 316,
VERIFY ALIGN W1 EX HEAP HEIGHT
TOTAL EXTERIOR
POOR AFEA-.
0.00
MANUFACTURER: INTERIOR: SIMPSON OR APPROVED EQUAL S.C. FLAT PANEL POOR; FAINT GRAPE; MATCH EXISTING
NOTES:
1. VERIFY ROUGH OPENING SIZES WITH SELECTED MANUFACTUPER REQUIREMENTS
2. SEE ELEVATIONS FOR CONFIGURATION
3. VERIFY ALL 51ZES AND ROUGH OPENINGS PRIOR TO CONSTRUCTION
4. CONTACT ARCHITECT IMMEDIATELY WITH QUESTIONS
POCKET SWING
WINDOW SCHEDULE
ID
I ROUGH OPENING 'SEE N21�
ROUGH HEAD �
FROM SUBFLR.
TYPE
OPER
�AREA
(SF)
NOTES
U-VAL
IWIDTH HEIGHT
MAIN FLOOR
-- 1 01 jw-& J�Y-6-
JA JH.5. 115.70 JVERIFYALI N W/ EX HEAP HT; SILL TO MATCH COUNTEFTOP MATEFET _o3o
Fil-AL EXTERIOR WINDOW AREA*
15.70 1
MANUFACTUPEF: ANDERSEN 100 SERIES FIDPEX WINDOWS; INTERIOR: WHITE. EXTERIOR: WHITE. VERIFY SELECTION W/ OWNER
NOTES:
1. VERIFY ROUGH OPENING SIZES WITH SELECTED MANUFACTURER FEQUIREMENI`5
2. SEE ELEVATIONS FOR CONFIGURATION
3. VERIFY ALL SIZES AND ROUGH OPENINGS PRIOR TO CONSTRUCTION
4. VERIFY EXISTING ROUGH OPENINGS WHERE WINDOWS ARE DEING REPLACED IN THE EXISTING OPENINGS PRIOR To OPPEFING
THE WINDOWS
5. CONTACT AFGHITECTIMMEPIATELY WITH QUESTIONS
6. TRANSLUCENT GLASS TO E5E SATIN ETCH. PROVIDE GLASS SAMPLE TO OWNER/ARCH FOR APPROVAL PRIOR TO ORDERING
KEY
A = AWNRG
C = CASEMENT
H.S. = HORIZONTAL SUPER
P = PICTURE
S.H. = SINGLE HUNG
H = HOPM
w (o
C-) c"I
z 3�. c:)
00
W cl) cy)
w U)
C14 Q
C,4 Z
c) 0
00
_j 00
< U-I
a:
REGISTERED
ARCHITECT
HEIDI MICHELLE HELGE N
VAMOFWASHINGMN
H 2 D
AR C H ITE CT U R E
D E S I G N
23020 EDMONDSWAY, #113
EDMONDS, WA 98020
P. 206 . 542 . 3 7 34
www.h2darchilecis.com
DATE: 1/11/2019
REVISEP: 12/12/2019
PERMIT SET
WINDOWANDDOOR
SCHEDULES
RESUB
DEC 19 2919
D"D- DEPARTMENT
Cay OF EDMONDS
A1.3
— - — - — - — - — - — - — - — - — - — HEIW VUl=-45-52CL — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — -
CONTINUOUS RIDGE VENT
EXISTING ROOFING TO PEMAT
— — - — - — - — - EX RIDGE EL = 04 1/6'
30 YP ARCHITECTURAL
(TO T.O. RIDGE)
ASPHALT COMPOSITE
ELEY = 443Y
ROOFING TO MATCH
---- ------------------
EX MAIN FLOOR PLATE EL = 7-10 1/6'
(TO T.Q. Tor PLATE)
EXISTING ",,Ell 1. 1
EX
ELEV = 4W.2'+/-
TO REMAIN, FAINT, TYP—
SIDING TYPE 1:
FIDERCEMENT LAP 51PING
m
/�15TING
0 AREA OF ADDITION;
EXISTING,
PAINTED. TYP--------_
EX MAIN FLOOR EL = C-O"
(TO T.O. 5UDFLOOP)
VE
ELEV�A30-4��L-
— - — - — - — -
---�—EX15TING
EX GARAGE FLOOR tL = -945" T
FOSTS
(To T.O. S.O.G.)
ELEY = 429.9 +/-
NORTH ELEVATION
SCALE: 1/W' = 1�0"
-- — - — - — - — - — - — - — - — - — - — - — - — - — - — - — --- ilalIau F I IlviM = �JWV - — - — - — - — - — - — - — - — - — - — - — - — - — - — --
EX15TING CHIMNEY
REPLACE EX15TING SIDING
CONTINUOUS RIDGE VENT
510ING TYPE 2:
130APP & 13ATTEN SIDING;
------ ...... .... ..
..... ..... ...................
FAINTED, TYP FX RIDGE EL - 0-4 10'
. ............
30 YP ARCHITECTURAL
(TO f�d RIDGE)
ELEV = 443.7
ASPHALT COMPOSITE
ROOFING TO MATCH EXISTING 12
12
EXISTING ROOFING TO
4.5+/-]
-14,5+/-
REMAIN
5/4)(8 IND FASCIA. TYP
TO MATCH EXISTING
12 2.5+/-
......
EX MAIN FLOOR PLATE EL = TIO 11V
�LAT
CFO T.0 TOP E;�
ELEY = 4W.2 +/-
WING, TYPE 2:
DOAFP & DATTEN SIPING;
T-10"
PAINTED. TYP
EX15TING EXPOSED CMU
2x6 TRIM [�3OAPP
--------
TO REMAIN; PAINT. TYP
51PINGG TYPE 1:
FIDERCEMENT LAP SIPING
,-EXiSTIW, POSTS TO
0 AREA OF ADDITION;
REMAIN EX MAIN FLOOR EL = 01-0"
F,AJNTEP. TYP
(TO T.O. SUDFLOOP)
AV F�
-F� I r--TfNG—GW0E- -- 7 F LE� —4324�+I-
...... ...... ......
...... ...... ...... ......
...... ...... ......
EX GARAGE FLOOR EL = -U-U' T
(To T.O. S-O-G-)
ELEV = 429.91 +/-
EAST ELEVATION
OCALE:114' - l'-U'
w C.0
0 c"I
z 3: c:)
00
W U) 0)
T <
U)
Lij - c/)
04 r)
N Z
c) 0
00 '
00 2i
0
w
9716 REG18TERED
�ARCHFMCT
�HEDI �K.HEILE"—.
MnOF.�HINGTON
H 2 D
A R C H I T E C T U R E
D E S ' I G N
23020 EDMONDSWAY, #113
EDMONDS, WA 98020
P. 206 . 54 2 . 3 7 34
www.h2darchitects.com
DATE: 1/11/2019
FEVISEP: 12/12/2019
PERMIT SET
EXTERIOR ELEVATIONS
RESUB
DEC 19 2019
BUILDING DEPARTMENT
CITY OF EDMONDS
A2.0
-- — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — HEJC±E LjNff-= 4*5. '
5 - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — -
EX15TING CHIMNEY
EXISTING ROOFING TO
REMAIN
CONTINUOUS RIPGE VENT
- - - - - - - - - - - - - - - - - - - - - - - - - -
EX RIDGE EL = IV-4 1/6'
(TO T.O. RIDGE)
W YR AFCHITECTUPAL
ELEV = 443.7'+/-
ASPHALT COMP051TE
ROOFING TO MATCH EXISTING
514X6 IND FASCIA, TYP
TO MATCH EXISTING
EX MAJN FLOOR PLATE EL - T-10 1/6'
(TO T.O. TOP PLATE) T
E
EX D.S.
EXI NG
EX15TIK-
-'-51PlNGTYPF1:
FIDERCEMENT LAP SIDING
0 AREA OF ADDITION,
PAINTED. TYr
EX MAIN FLOOR EL = 0�0"
ECK
-J�VERAGE FA2E 45OB
EVlqT G GRADE
(ro T.O. SUDFLOOR)
ELEY- -45a4�:F/z A
\����EXISTING,
(,AKAUE FLOOR EL = -0-6- T
(TO T.O. SAG.)
EXPOSEP
ELEV = 4292
CMU TO REMAIN; FAINT,
Tyr
SOUTH
SCALF-1/4* = W
ATION
- — - — - — - — - — - — - — - — - — - — - — - — - — --- b QQ[ f Uw-= -45.�-xV - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - —
FASTING CHIMNEY
...... ----- - - ---------------------- --- ---------------- - -------------------------- FX RIDGE El - VY-4 11H'
(TO
12 ELEV lop"0171-
4.5+/-, :�Z7
25+1-rj2—
EXISTING EXP05ED CMU
TO REMAIN. PAINT, TYP—
EXISTING, POSTS TO
REMAIN, DEYOND----.
L
EXISTING GRAPE
WEST ELEVATION
SCALF-W = 1'-0'
RACE C,&AP� = 4N
-AVE
EX MAIN FLOOR PLATE EL =7-10 Wl
(TO T.O. TOP PLATE) T
ELEY = 43&2'+/-
EX MAIN FLOOR EL = 01-9'
(TO T.O. SUDFLOOP)
-- — - — - — - — --- ELEV -=430 -E-+L-
-----------
7PAPE FX GARAGE FLOOR EL = -a-&- T
(TO T.O. S.O.G.)
ELEV = 429.9 +/-
co
CN
z �: C)
Co
ui cn
U)
C\j Z
c� 0
co
co
< w
T—
V 9716
REOISTERED
A V
.C'
RCHITECT
HEIDI MICH—E HELGE
STATEOMMIAINGTON
H 2 D
ARCHITECT U R E
D E S I G N
23020 EDMONDSWAY, #113
EDMONDS, WA 98020
P. 206 . 54 2 . 3 7 34
www.h2darchitects.com
DATE: I/IM019
FIEVISEP: 12/12/2019
PERMIT SET
EXTERIOR ELEVATIONS
RESUB
DEC 19 2019
BUN"N"or TMENT
ClIlOFEi=NDS
A2.1
BUILDING SECTION
SCALE- 1/#' - 10'
TYP ROOF A55EMDLY
METAL EDGE FLA51-OW,
— — — — - mil 514X WP FAW& FAINTED. TYP
I ��l VERIFY TO MATCH EXISTING
--------------
TYPICAL RAWA55EMOLY
112'T&G SOFFIT STAINED TO MATCH
EXISTING
SIDING PER ELEVATION
TYP NEWROOF ASSEMBLY
-30 YEAR ASPHALT COMP051TE ROOF TO MATCH EXISTING
-HENRY 5LUE5KIN RF200 (OR 5ErrEF) DRAINAGE PLANE INSTALL SHINGLE FASHION
-CDX PLYWOOD SHEATHING PER STPUCTURAL
-PREMANUFACTUREP TPU55ES BY OTHERS
-MIN F-49 INSULATION 0 ATTIC
-5/&'GWD
— — — — — — -PVA PRIMER
RAKE ASSEMBLY PER DETAIL
-SIDING PEP ELEVATION
-HENRY DLUESKIN VP100 (OR BETTER) 13UILPING WRAP
-PLYWOOD SHEATHING PEP STRUCTURAL
-FPAM[Nr, PEP STPUCTUPAL
-R-21 BATT INSULATION
-1/2" GWB
-rVA PRIMER
TYP NEW MAIN FLOOR ASSEMBLY
-FINISH FLOOR
-SHEATHING PER STFUCTURAL
-FRAMING PER STFUCTURAL
-MIN R,30 INSULATION OVER UNCONDITIONED SPACE
Y_ IND CAP 0 FURR WALL. PAINTED
,�21 PIGIP INSULATION 0 FUPP WALL IN CL05ET
TEMPPOOF 250GG, XYPEX. OR APPROVED EQUAL WATERPROOFING a
ALL NEW AND EXPOSED EXISTING BELOW GRAPE FOUNDATIONS, TYP
4j'PEFFOPATEE) FOOTING DPAIN IN DPAIN POCK PER CITY OF EDMONDS
REQUIREMENTS; TIE INTO EXISTING PPAIN SYSTEM.
SURROUND 4'PERFORATEP PVC PIPE DRAIN 13Y G" MIN 1" MINUS WASHED POCK
ENCIRCLED WITH NON -WOVEN GEOTEXTILE FILTER FABRIC (MJKAFI 14PN, 3UPAC 4Nr OR
51"; AT HIGHEST f2GIN7 PERFORATED PIPE INVERT SHOULD 13E AT LEAST 6' 13ELOW
DIM OF SLAD FLOOR OR LEVEL OF CRAWLSPACE. DISCHARGE PIPE FOP SU13SUPFACE
PRAINS SHOULD 13E SLOPED FOP FLOW TO OU`rl_ET POINT.
FOUNDATION AND FOOT114G PEP STRUCTURAL
FOUNDA11ON AND FOOTING PER 5TPUCTURAL
WALL SECTION
EX151ING NEW
I — — __"
1- -0
4.5.1-r-12--
H
ING, 2.5+/- 12 EX ATTIC
VERIFY
EX LIVING
EX
I V, kLKWAY
EXISTING
�j + 4RAPE
EX CRAWL
BUILDING SECTION
TYP NEW ROOF ASSEM13LY
2x__ FULL -DEPTH BLOCKING Wl (2) 2" PEEP V-NOTCHE5 PEP 15AY
W1 NON COFRO51YE WIRE INSECT SCREEN OYER
METAL EDGE FLASHING, TYP
K-STYLE METAL GUTTER; PAINTED
5/4X6 WID TRIM. FAINTED —
COP-A-YENT 5400 (OR APPROVED EQUAL) CONTINUOUS p-A
FLUSH SOFFIT VENT
1/2" T&G SOFFIT TO MATCH EXIS [ING
TYP NEW EXTERIOR WALL ASSEMBLY
TYPICAL EAVE ASSEMBLY 0 ADDITION
T.-il-c. *VERIFY TO MATCH EXISTING—
TYP EMSTING ROOF ASSEMBLY
-EXISTING ROOFING
-EXISTING DRAINAGE PLANE/ROOFING PAPER
-EXISTING SHEATHING
-EXIST;NG, FRAMING
-EXIST NG AIR SPACE OF BAFFLE FOR 2" MIN AIR SPACE
_EXJSTING INSULATION OR R-49 MIN BATT OR DLOWWN CELLULOSE INSULATION;
P49 PIGIP INSULATION 0 EDGES AS NEEDED
-5/6'GWD
-PVA PRIMER
EXISTING EAVE ASSEMBLY
-EXis,nNr, EXP05EP CMU: PAINTED.TYP
-PRO CLIMA VISCONN LIQUID MEMBRANE (APPLIED TO INTERIOR SIDE OF CMU)
-FURRING STRIPS
-2X6 FPAMINIG PEP STRUCTURAL W/ P.T. SILL PLATE
-MIN R-21 13ATT INSULATION
-PRO CLTMA INTELLO PLUS MEMBRANE AIR 13AFFIER AND VAPOR CONTROL
LAYER
-112, GW5
EX15TING
EXISTING
CRAWL
WALLSECTION
—LE:- = 1-'
TYP NEW MAIN FLOOR ASSEMBLY
-FINISH FLOOR
-SHEATHING PER STRUCTURAL
-FRAMING PER STFUCTUPAL
-EX INSULATION MIN R,30 INSULATION OVER UNCONDITIONED
SPACE CID EXPOSED AREAS OF ALTERATION
SILL PLATE W/ SILL SEALER
JING FOOTING PPAIR VERIFY
EXISTING FOUNDATION AND FOOTING
VERIFY
KITCHEN 7'EX
E;
4L
Lu co
C) c\I
z 3: C:)
00
Lu U) 0)
Q <
Lij U)
C'4 Z
C) 0
co
_j 00
< w
r
, FREGISTERID
"T.0
'T
.C� TEO
'T
HEIDI MICHELLE HELGE ON
!ITATEOFWMHINGTON
H 2 D
A R C H I T E C T U R E
D E S I G N
23020 EDMONDSWAY, #113
EDMONDS, WA 98020
P. 206 . 54 2 . 3 7 34
www.h2darchitects.com
DATE: 1111/2019
FEVISEP: 12/12/2019
PERMIT SET
BUILDING SECTIONS AND
WALL SECTIONS
RESUB
DEC 19 2019
BUILDING DERkRTMENT
CrrYOFEDMONDS
A3.0
P-10 FOAM 0 HEADER TYF--7
WEATHER FE51STIVE
FOLD UP HENRY 13LUESKIN
WEATHER PESISTIYE BARRIER
AND TEMPORARILY SECURE
HEADER PER STRUCTURAL
OR EXIST_�_.
1/2"
P
BEA I
SO F
OR L_�.
WITH JOINT
COMPOUND- LINTEL PEP STPUCTUPAL
WINDOW PER WINDOW
r4_-� TYP WINDOW HEAD
SILL BELOW
-TYP EXTERIOR
WALL ASSEMBLY
SELF-APt-ESIVE WATERPROOF
MEM13PANE INSTALL PEP 7/A4.1
J-5TOP OR L-13EAP WITH
JOINT COMPOUND
GOPHER 13EAP
TYP WINDOW JAMB
V1101,
5ILL PEP TYP DETAIL
STONE SILL TO MATCH EX
5ELF-ADHESIVE WATERPROOF
MEMBRANE. INSTALL PER 7/A4.1
Tyr EXTERIOR
WALL A55EMDLY
TYP WINDOW SILL
I. = 0.' TYPICAL WINDOW NOTE:
1. INSTALL 13ACKER POP ANP/OP FOAM INSULA11ON 0
ANY GAP BETWEEN WINDOW AND ROUGH FRAME. TYP
EX LINTEL OR PEP
STRUCTURAL
TILE OVER EASTING, CMU
WATERPROOFED EXTERIOR WALL
13ACKEP DRD.
WRAP TILE 0
WINDOW HFAP)7
SEALANT
2X2 DPICKMUP TPIM TO
MATCH EXISTING, -
WINDOW PER WINDOW
SCHEDULE
STONE SILL TO MATCH
NOTUSEP
WEATHER PESISTIYE
INSTALLED
z WINDOW
3
WINDOW FLASHING
1. CUT THE DLUESKIN FLUSH WITH THE FOUGH
OPENING
NOT USED 2. CUT THE BLUE5KIN AT 45 DEGREE ANGLE TO A
POINT 9 UP AND 9'OUT FROM THE UPPER CORNERS
OF THE FOUGH OPENING
3. FOUP UP 13LUESKIN FLAP AT HEAP AND
TEMPORARILY SECURE WITH TAPE
NOT USED
4. CUT DLUESKIN WF25 (4') TO FIT THE DEPTH OF
THE SILL ADDING, a'OVEPHANG TO THE EXTERIOR
5. FOLP DLUESKIN Wr25 ALONG THE SPLIT BACKING
PAPER
6. SLIDE INTO CORNER
7. FEEL OFF ONE BACKING STRIP AFTER ANOTHER
AND PRESS ON FIRMLY
8. 5TAR7nNG AT THE CORNER, SPREAD THE L005E
END OF THE OLUESKIN WP25 GRADUALLY ONTO THE
WALL FACE
a USE 130TH THUM135 FOR A UNIFORM APPLICATION
ANP PPE55 ON FIRMLY
10. FEFEAT STEPS & AND 9 TO SEAL ALL CORNERS
RIOR SHEATHING
PLATE
DLUESKIN WP25
HENRY 13LUE5KIN
WF25 4�' OR G', NO
CLrr5 NECESSARY 0
CORNER
15. REPEAT 5TEP511-14 TO SEAL ALL EDGES OF THE
PO. 5ILL, JAM35, ANP HEAP
16. INSTALL THE WINDOW ACCORDING TO THE
MANUFACTURERS SPECIFICATIONS. UNLESS
5PECIFIEP. SEALANT 15 NOT REQUIRED DEHINP THE
NAIL FLANGE
17. USE DLUESKIN WF25 4!'OP WIPER TO COUNTER -
FLASH THE FLANGE IN WEATHEF-LAr FASION
18. BOTTOM FLANGE REMAINS UNTAPEO JAMB
FLASHING, EXTENDS 2" PAST LOWER EDGE OF FLANGE
19. HEAP FLASHING EXTENDS 1" PAST THE OUTER
EDGES Of THE JAMB FLASHING
20. DRAPE THE DLUESKIN FLAP OVER THE HEAP
FLASHING
21 5EAL THE 45 DEGREE CUTS WITH 13LUESKIN
11. CUT 13LUE5KIN WP25 6'OP WIPER TO LENGTH
(INSIDE TO IN51PE OF THE PO)
12. FOLD 13LUESKIN WP25 ALONG THE SPLIT
BACKING PAPER
13. RELEASE FIRST BACKING PAPER AND SEAL TO
PO
14. PEEL OFF SECOND 13ACKING PAPER AND SEAL
ONTO THE WALL FACE]FACAPE ANP PRESS ON
FIRMLY
�.7H�ENRY �BLUE�SKIN WP25 FLASHING DTL
GWD WRAP 0 TOP AND
SIPE OF WINDOW, TYP_r,
WINDOW PER WINDOW
SCHEDULE--'
5/4)(.- WOOD SILL,
PAINTED ���
HENRY
DLUESKIN WP25
SHEATHING
-FOLD UP 13LUESKIN WEATHER -
RESISTIVE DAPMEP &
TEMPORARILY SECURE
,-WEATHEF-PESISTIVE
5AFRJER
SIU. PLATE
HENRY 13LUESKIN WP25
7___000PNER
_Q>_NPY DLUESKIN
EFALTOFOFJ015TS
UNDER PECKING
TIE-IN WITH WEATHER FES15TIVE 13APFIER INSTRUCTIONS
1. INTEGRATE INSTALLATION OF HENRY DLUE5KIN WEATHEP-RE51STIVE
13ARPEF WITH HENRY 13LUESKIN W?25 TO FORM WATER SHEDDING LAPS
2.5CORE AND FOLD WEATHEP-RESISTIVE DARFiEF ABOVE HEADER TO
ALLOW FOR HEWPY DLUESKIN WP25 INSTALLATION
NOTES:
3. INSTALL HENRY DLUESKIN WP25 HEAD FLASHING UNDER WEATHER-
1. VISIT PESIDENTIALHENRY.COM FOP THE MOST CURRENT
FESISTWE BARRIER
DETAILS. INSTALLA11ON VIDEOS AND PRODUCT DATA SHEETS
4. FOLD WEATHEP-RESISTIVE DAPFIEF BACK OVER HEAD FLASHING AND
2. INSTALL HENRY DLUESKIN WP25 IN ORDER AS SHOWN BY
SEAL WITH HENRY DLUE5KIN TAPE
NUMDEP5
(�)_�HENRY BLUESKIN WP25 FLASHING DTL @ EXTERIOR
N
8 N.T.5.
IX5 HEAP TRIM
MITER CORNERS
�112"GWDTYP
lx5 WP TRIM a
WP TRIM PER TYP
SIDES-----,,, +
DETAIL 15/A4.0
NOT USEP
LINE OF POOP
JAMB. TYP
POOR FRAME
POOP PER POOP
POOP PER SCHEDULE
SCHEDULE
POOP PER SCHEDULE
POOP JAMB
WP TRIM PEP TYP
DETAIL 151A4.0
1/2" GW5
TYP WNDW HEAD @ SHOWER TYP EXT. WN DW TRIM TYP INT. WNDW T IM 1_cl� TYP INT. DOOR TRIM _�) TYP INT DOOR HEAD j_.7-jTYP INT DOOR JAMB
EX 'VERIFY TO MATCH EXISTING 13 1 3/#' = T-0, 'VERIFY TO M U5 1.=,`,.. "VERIP(TO MATCH EXISTING' U6 I. 1"=T-c'
(��_ U7
EXISTING CMU EXTEFIOP WALL
EXISTING WINDOW
WRAP TILE 0 WINDOW JAMB
TILE OVER WATERPROOFED
BACKER 130APP
TYPWALL,A55
1X6 WOOD 3ASE!MBLY
PAINTED -
FINISH FLOOR-ii, L
TYP WNDW JAMB @ SHOWER TYP WD BASE DTL
.3/4�' = T-9-
TILE OVER WATERPROOFED BACKER
BOAPP
WRAP TILE 0 SILL, SLOPE TO DRAIN
SEALANT
LOP EX WINDOW
EX STONE SILL
SELF-APHESIVE WATERPROOF
MEMBRANE INSTALL PER 7/A4.1
EXISTING CMU EXTEPIOP WALL
TYP WNDW SILL @ SHOWER
I.. = T-0.
CL
DOOP.WHEPEOCCUP5
FINISH WOOD FLOORING
STRIP.
SCHLUTER SCHE14E
ALUMINUM
y
TILE FLOORING
SUDFLOOR
( TYP WD TO TILE TRANSITION
9 2" = T-Gl'
* ml/_�
-THIN SET N
-CEMENT 13ACK 130AFP
-WATEPPPOOF MEMBRANE
-FRAMED WALL
RECE55ED SHELF
SLOPE StL TO DRAIN-
5]LL MATERIAL PER
FINISH 5CHEPULE--
BLOCKING -
FFAMEP WALL
*3YPRECESSED SHELF DTL
T'TRECESSED SHELF I-
20 T' = 1'-0"
w (c)
L) C\l
z 3: c�
00
W C/) 0)
T <
U)
w 04 0
C,4 Z
C) 0
00
_j 00
< w
FREGISTERED
GST
ARCHITECT
��.EUWELLE.EL.E...
S-OFWASHI-N
Rol
H 2 D
A R C H I T E C T U R E
D E S I G N
23020 EDMONDSWAY, #113
EDMONDS, WA 98020
P. 206 . 542 . 3 7 34
www.h2darchitects.com
DATE: 1/11/2019
FEVISEP: 12/12/2019
PERMIT SET
TYP. DETAILS
RESUB
DEC 19 2019
13U'LOINGDERNRIVENT
CffYOFEDMMDS
A4.0
GENERAL STRUCTURAL NOTES
(THE FOLLOWING APPLY UNLESS SHOWN OTHERWISE ON THE PLANS)
CRITERIA
1. ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THE
DRAWINGS, SPECIFICATIONS & THE INTERNATIONAL BUILDING CODE (2015 EDITION).
2. DESIGN LOADING CRITERIA:
FLOOR LIVE LOAD (RESIDENTIAL) . . . . . . . . . . . . . I . . . . 40 PSF
ROOF SNOW LOAD (Pf) . . . . . . . . . . . . . . . . . . . . . . . 25 PSF
WIND:
BASIC WIND SPEED (3-SECOND GUST) . . . . . . . . . . . . . . . . 110 MPH
WIND IMPORTANCE FACTOR (1w) . . . . . . . . . . . . . . . . . . . . . 1.0
WIND EXPOSURE . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
TOPOGRAPHICAL FACTOR (Kzt) . . . . . . . . . . . . . . . . . . . . . 1.67
EARTHQUAKE:
LAT. / LONG . . . . . . . . . . . . . . . . . . . . . . 47.802 / -122.352
SEISMIC IMPORTANCE FACTOR (le) . . . . . . . . . . . . . . . . . . . 1.0
SEISMIC USE GROUP . . . . . . . . . . . . . . . . . . . . . . . . . . . I
MAPPED SPECTRAL RESPONSE (Ss/SI) . . . . . . . . . . . . . . 1.267g/0.50g
SPECTRAL RESPONSE COEF. (SOS/SDI) . . . . . . . . . . . . . 0.844g/0.50g
SEISMIC FORCE RESISTING SYSTEM: . . . . . . . . . . PLYWOOD SHEAR WALLS
DESIGN BASE SHEAR . . , 22.87k
SEISMIC RESPONSE COEFICii�T icg) 0.130
SEISMIC DESIGN CATEGORY . . . . . . . . . . . . . . . . . . . . . . . . D
RESPONSE MODIFICATION FACTOR (R) . . . . . . . . . . . . . . . . . . 6.5
ANALYSIS PROCEDURE . . . . . . . . . . . . . . . EQUIVALENT LATERAL FORCE
REFERENCE: USGS NATIONAL SEISMIC HAZARD MAPPING PROJECT, 2008 DATA
3. STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH ARCHITECTURAL
DRAWINGS FOR BIDDING AND CONSTRUCTION. CONTRACTOR SHALL VERIFY DIMENSIONS
AND CONDITIONS FOR COMPATIBILITY AND SHALL NOTIFY ARCHITECT OF ANY
DISCREPANCIES PRIOR TO CONSTRUCTION.
4. CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS, MEMBER SIZES, AND CON-
DITIONS PRIOR TO COMMENCING ANY WORK. ALL DIMENSIONS OF EXISTING CON-
STRUCTION SHOWN ON THE DRAWINGS ARE INTENDED AS GUIDELINES ONLY AND MUST
VERIFIED, CONTRACTOR SHALL DETERMINE THE LOCATION OF ALL ADJACENT
UNDERGROUND UTILITIES PRIOR TO COMMENCING EXCAVATION. THE CONTRACTOR SHALL
BRING ALL CONFLICTS AND DISCREPANICES TO THE ATTENTION OF THE ARCHITECT
AND STRUCTURAL ENGINEER.
5. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS BEFORE COMMENCING ANY
DEMOLITION. SHORING SHALL BE INSTALLED TO SUPPORT EXISTING CONSTRUCTION
AS REQUIRED AND IN A MANNER SUITABLE TO THE WORK SEQUENCES. EXISTING
REINFORCING SHALL BE RETAINED UNDAMAGED WHERE NOTED ON THE PLANS.
DEMOLITION DEBRIS SHALL NOT BE ALLOWED TO DAMAGE OR OVERLOAD THE EXISTING
STRUCTURE. LIMIT CONSTRUCTION LOADING (INCLUDING DEMOLITION DEBRIS) ON
EXISTING FLOOR SYSTEMS TO 40 PSF. ALL NEW OPENINGS THROUGH EXISTING
CONCRETE OR MASONRY WALLS, SLABS AND BEAMS SHALL BE ACCOMPLISHED BY SAW
CUTTING WHEREVER POSSIBLE,
6. CONTRACTOR SHALL PROVIDE TEMPORARY BRACING FOR THE STRUCTURE AND
STRUCTURAL COMPONENTS UNTIL ALL FINAL CONNECTIONS HAVE BEEN COMPLETED IN
ACCORDANCE WITH THE PLANS.
7. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE
METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES REQUIRED TO PERFORM THE WORK.
THE STRUCTURAL ENGINEER HAS NO OVERALL SUPERVISORY AUTHORITY OR ACTUAL
AND/OR DIRECT RESPONSIBILITY FOR THE SPECIFIC WORKING CONDITIONS AT THE
SITE AND/OR FOR ANY HAZARDS RESULTING FROM THE ACTIONS OF ANY TRADE CON-
TRACTOR. THE STRUCTURAL ENGINEER HAS NO DUTY TO INSPECT, SUPERVISE, NOTE,
CORRECT, OR REPORT ANY HEALTH OR SAFETY DEFICIENCIES OF THE OWNER, CON -
CONTRACTORS, OR OTHER ENTITIES OR PERSONS AT THE PROJECT SITE.
B. SPECIAL INSPECTION OF EPDXY GROUTED INSTALLATIONS SHALL BE PROVIDED IN
ACCORDANCE WITH SECTIONS 109 AND 1704 OF THE INTERNATIONAL BUILDING CODE
AND THE PROJECT SPECIFICATIONS BY A QUALIFIED TESTING AGENCY DESIGNATED
BY THE ARCHITECT, AND RETAINED BY THE BUILDING OWNER. THE ARCHITECT,
STRUCTURAL ENGINEER, AND BUILDING DEPARTMENT SHALL BE FURNISHED WITH
COPIES OF ALL INSPECTION AND TEST RESULTS.
GEOTECHNICAL
9. FOUNDATION NOTES: ALLOWABLE SOIL PRESSURE AND LATERAL EARTH PRESSURE ARE
ASSUMED AND THEREFORE MUST BE VERIFIED BY A QUALIFIED SOILS ENGINEER. IF
SOILS ARE FOUND TO BE OTHER THAN ASSUMED, NOTIFY THE STRUCTURAL ENGINEER
FOR POSSIBLE FOUNDATION REDESIGN.
FOOTINGS SHALL BEAR ON FIRM, UNDISTURBED EARTH AT LEAST W BELOW ADJACENT
FINISHED GRADE. UNLESS NOTED OTHERWISE, FOOTINGS SHALL BE CENTERED BELOW
COLUMNS OR WALLS ABOVE. BACKFILL BEHIND ALL RETAINING WALLS WITH FREE
DRAINING, GRANULAR FILL AND PROVIDE FOR SUBSURFACE DRAINAGE.
ALLOWABLE SOIL PRESSURE . . . . . . . . . . 2,000 PSF
LATERAL EARTH PRESSURE . . . . . . . . . . . 35 PCF
CONCRETE
10. CONCRETE SHALL BE MIXED, PROPORTIONED, CONVEYED AND PLACED IN ACCORD-
ANCE WITH ACI 301. CONCRETE SHALL ATTAIN A 28 DAY STRENGTH OF F'C = 2,500
PSI AND MIX SHALL CONTAIN NOT LESS THAN 5-1/2 SACKS OF CEMENT PER CUBIC
YARD AND SHALL BE PROPORTIONED TO PRODUCE A SLUMP OF 5" OR LESS.
THE MINIMUM AMOUNTS OF CEMENT AND MAXIMUM AMOUNTS OF WATER MAY BE CHANGED
IF A CONCRETE PERFORMANCE MIX IS SUBMITTED TO THE STRUCTURAL ENGINEER AND
THE BUILDING DEPARTMENT FOR APPROVAL TWO WEEKS PRIOR TO PLACING ANY CON-
CRETE. THE CONCRETE PERFORMANCE MIX SHALL INCLUDE THE AMOUNTS OF CEMENT,
FINE AND COARSE AGGREGATE, WATER AND ADMIXTURES AS WELL AS THE WATER CE-
MENT RATIO, SLUMP, CONCRETE YIELD AND SUBSTANTIATING STRENGTH DATA IN
ACCORDANCE WITH ACI 301. REVIEW OF MIX SUBMITTALS BY THE ENGINEER OF
RECORD INDICATES ONLY THAT INFORMATION PRESENTED CONFORMS GENERALLY WITH
CONTRACT DOCUMENTS. CONTRACTOR OR SUPPLIER MAINTAINS FULL RESPONSIBILITY
FOR SPECIFIED PERFORMANCE.
ALL CONCRETE WITH SURFACES EXPOSED TO STANDING WATER SHALL BE AIR
ENTRAINED WITH AN AIR ENTRAINING AGENT CONFORMING TO ASTM C260, C494, AND
C618. TOTAL AIR CONTENT SHALL BE IN ACCORDANCE WITH TABLE 19.3.2.1 OF THE
ACT 318.
11. REINFORCING STEEL SHALL CONFORM TO ASTM A615 (INCLUDING SUPPLEMENT SI),
GRADE 60, FY = 60,000 PSI. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A 185.
ALL REBAR SHALL BE 90% MINIMUM RECYCLED CONTENT. SUBMIT MANUFACURERS
CERTIFICATE OF RECYCLED CONTENT TO ARCHITECT AND STRUCTURAL ENGINEER.
12. REINFORCING STEEL SHALL BE DETAILED (INCLUDING HOOKS AND BENDS) IN ACCORD-
ANCE WITH ACT 318. LAP ALL CONTINUOUS REINFORCEMENT 40 BAR DIAMETERS
OR 2' 0" MINIMUM. PROVIDE CORNER BARS AT ALL WALL AND FOOTING INTER-
SECTIONS. LAP CORNER BARS 40 BAR DIAMETERS OR 2' 0' MINIMUM. LAP
ADJACENT MATS OF WELDED WIRE FABRIC A MINIMUM OF 8" AT SIDES AND ENDS.
13. CONCRETE PROTECTION (COVER) FOR REINFORCING STEEL SHALL BE AS FOLLOWS:
A. FOOTINGS AND OTHER UNFORMED SURFACES, EARTH FACE . . . 3'
B. ALL OTHER SURFACES . . . . . . . . . . . . . . . . 1 1/2"
ANCHORAGE
14. EPDXY -GROUTED ITEMS SPECIFIED ON THE DRAWINGS SHALL BE GROUTED WITH
'SET-XP" HIGH STRENGTH EPDXY AS MANUFACTURED BY THE SIMPSON COMPANY
AND INSTALLED IN STRICT ACCORDANCE WITH ICC ESR 2508.
15. EPDXY -GROUTED ITEMS SPECIFIED ON THE DRAWINGS SHALL BE GROUTED WITH
ILI
WOOD
18. FRAMING LUMBER SHALL BE KILN DRIED OR MC-15, AND GRADED AND MARKED IN CON-
FORMANCE WITH WCLIB STANDARD GRADING RULES FOR WEST COAST LUMBER NO. 17,
JOISTS: (2X MEMBERS) HEM -FIR NO. 2
MINIMUM BASE VALUE, FB = 850 PSI
(3X & R MEMBERS) DOUGLAS FIR NO. I
MINIMUM BASE VALUE, FB = 1000 PSI
STRUCTURAL LIGHT FRAMING.,
DOUGLAS FIR NO. 2
(INCL. 3X AND 4X POSTS)
MINIMUM BASE VALUE, FB = 900 PSI
BEAMS AND STRINGERS:
DOUGLAS FIR NO. 1
(INCL. 6X AND LARGER)
MINIMUM BASE VALUE, FB = 1350 PSI
POSTS AND TIMBERS:
DOUGLAS FIR NO. I
(6X6 AND LARGER )
MINIMUM BASE VALUE, FC = 1000 PSI
STUDS, PLATES & MISC. FRAMING:
DOUGLAS FIR OR HEM -FIR STANDARD GRADE
2X6 STUDS AND PLATES: HEM -FIR NOA/ STUD GRADE
2X AND 3X T & G DECKING HEM -FIR COMMERICAL DEX,
MINIMUM BASE VALUE, FB = 1350 PSI
. ZL
20. PREFABRICATED CONNECTOR PLATE WOOD ROOF TRUSSES SHALL BE DESIGNED BY THE
MANUFACTURER IN ACCORDANCE WITH THE "NATIONAL DESIGN STANDARD FOR_METAL
THE SPANS AND CONDITIONS SHOWN ON THE PLANS. LOADING SHALL BE AS FOLLOWS:
A. TOP CHORD LIVE LOAD . . . . . 25 PSF
B. TOP CHORD DEAD LOAD . . . . . 10 PSF
C. BOTTOM CHORD DEAD LOAD . . . . 5 PSF
0. TOTAL LOAD . . . . . . . . . 40 PSF
WOOD TRUSSES SHALL UTILIZE APPROVED CONNECTOR PLATES (GANGNAIL OR EQUAL).
SUBMIT SHOP DRAWINGS AND DESIGN CALCULATIONS TO THE ARCHITECT AND STRUCT-
STRUCTURAL ENGINEER FOR REVIEW PRIOR TO FABRICATION. SUBMITTED DOCUMENTS
SHALL BEAR THE STAMP AND SIGNATURE OF A REGISTERED PROFESSIONAL ENGINEER,
STATE OF WASHINGTON. PROVIDE FOR SHAPES, BEARING POINTS, INTERSECTIONS,
HIPS, VALLEYS, ETC., SHOWN ON THE DRAWINGS. EXACT COMPOSITION OF SPECIAL
HIP, VALLEY, AND INTERSECTION AREAS (USE OF GIRDER TRUSSES, JACK TRUSSES,
STEP DOWN TRUSSES, ETC.) SHALL BE DETERMINED BY THE MANUFACTURER UNLESS
SPECIFICALLY INDICATED ON THE PLANS. PROVIDE ALL TRUSS TO TRUSS AND TRUSS
TO GIRDER TRUSS CONNECTION DETAILS AND REQUIRED CONNECTION MATERIALS.
PROV I DE FOR ALL TEMPORARY AND PERMANENT TRUSS BRACING AND BRIDGING.
ALL LUMBER IN TRUSSES SHALL BE FSC CERTIFIED AND SHALL BEAR THE FSC
STAMP.
PLYWOOD SHEATHING SHALL BE GRADE C-D, EXTERIOR GLUE OR STRUCTURAL 11,
EXTERIOR GLUE IN CONFORMANCE WITH APA STANDARDS. ORIENTED STRAND
BOARD OF EQUIVALENT THICKNESS, EXPOSURE RATING AND SPAN RATING MAY BE
USED IN LIEU OF PLYWOOD.
A. ROOF SHEATHING SHALL BE 1/2' (NOM.) WITH SPAN RATING 24/0.
B. FLOOR SHEATHING SHALL BE 3/4' (NOM.) WITH SPAN RATING 40/20.
C. WALL SHEATHING SHALL BE 112- (NOM.) WITH SPAN RATING 24/0.
REFER TO WOOD FRAMING NOTES BELOW FOR TYPICAL NAILING.
ALL SHEATHING SHALL BE FSC CERTIFIED AND SHALL BEAR THE FSC STAMP
ALL WOOD IN DIRECT CONTACT WITH CONCRETE OR MASONRY SHALL BE PRESSURE -
TREATED WITH AN APPROVED PRESERVATIVE OR (2) LAYERS OF ASPHALT IMPREGNATED
BUILDING PAPER SHALL BE PROVIDED BETWEEN UNTREATED WOOD AND CONCRETE OR
MASONRY. ALL WOOD EXPOSED TO WEATHER WITHOUT THE ADEQUATE PROTECTION OF
A ROOF OR EAVE SHALL BE AN APPROVED WOOD OF NATURAL RESISTANCE TO DECAY
OR PRESSURE TREATED. SUCH MEMBERS INCLUDE HORIZONTAL MEMBERS SUCH AS
GIRDERS, JOISTS, AND DECKING; OR VERTICAL MEMBERS SUCH AS POSTS, POLES,
AND COLUMNS.
TIMBER CONNECTORS CALLED OUT BY LETTERS AND NUMBERS SHALL BE 'STRONG -TIE*
By SIMPSON COMPANY, AS SPECIFIED IN THEIR MOST RECENT CATALOG. EQUIVALENT
DEVICES BY OTHER MANUFACTURERS MAY BE SUBSTITUTED, PROVIDED THEY HAVE ICC
APPROVAL FOR EQUAL OR GREATER LOAD CAPACITIES. PROVIDE NUMBER AND SIZE OF
FASTENERS AS SPECIFIED BY MANUFACTURER. CONNECTORS SHALL BE INSTALLED IN
ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. WHERE CONNECTOR STRAPS
CONNECT TWO MEMBERS, PLACE ONE-HALF OF THE NAILS OR BOLTS IN EACH MEMBER.
ALL BOLTS IN WOOD MEMBERS SHALL CONFORM TO ASTM A307. PROVIDE WASHERS
UNDER THE HEADS AND NUTS OF ALL BOLTS AND LAO SCREWS BEARING ON WOOD. UN-
LESS NOTED OTHERWISE, ALL NAILS SHALL BE COMMON. ALL SHIMS SHALL BE SEA-
SONED AND DRIED AND THE SAME GRADE (MINIMUM) AS MEMBERS CONNECTED. HANGERS
IN DIRECT CONTACT WITH PRESERVATIVE -TREATED WOOD SHALL BE EITHER STAINLESS
STEEL (SST300), POST HOT -DIPPED GALVANIZED(HDG) OR GALVANIZED WITH A MINI-
MUM OF 1.85OZ ZINC PER SQUARE INCH (ZMAX). UNLESS NOTED OTHERWISE, ALL
LUMBER JOISTS SHALL BE CONNECTED TO FLUSH BEAMS WITH *LUS' SERIES JOIST
HANGERS, AND ALL TJI JOISTS SHALL BE CONNECTED TO FLUSH BEAMS WITH 'ITT'
OR "IUT" SERIES JOIST HANGERS.
NAILS - NAIL SIZES SPECIFIED ON DRAWINGS ARE BASED ON THE FOLLOWING
SPECIFICATIONS:
Harriott Valentine
Harriott Valentine Engineer, -
1932 First A--, Slit, 720
IF CONTRACTOR PROPOSES THE USE OF ALTERNATE STAPLES, THEY SHALL SUBMIT
Seattle, Washington 98101-2447
STAPLE SPECIFICATIONS TO THE STRUCTURAL ENGINEER (PRIOR TO CONSTRUCTION)
tat 206 624 4760 to, 206 447 6971
FOR REVIEW AND APPROVAL. STAPLESSHALLBE DRIVENFLUSH TO FACE OF
-.1h.matwinwins.r..
SHEATHING WITH NO COUNTERSINKING PERMITTED.
WOOD FRAMING NOTES THE FOLLOWING APPLY UNLESS OTHERWISE SHOWN:
A. ALL WOOD FRAMING DETAILS NOT SHOWN OTHERWISE SHALL BE CONSTRUCTED
TO THE MINIMUM STANDARDS OF THE INTERNATIONAL BUILDING CODE. MINIMUM
NAILING, UNLESS OTHERWISE NOTED, SHALL CONFORM TO TABLE 2304. 10. 1 OF
THE INTERNATIONAL BUILDING CODE. UNLESS NOTED OTHERWISE, ALL NAILS
SHALL BE COMMON. COORDINATE THE SIZE AND LOCATION OF ALL OPENINGS
WITH MECHANICAL AND ARCHITECTURAL DRAWINGS. PROVIDE WASHERS UNDER
THE HEADS AND NUTS OF ALL BOLTS AND LAG SCREWS BEARING ON WOOD.
B. WALL FRAMING: ALL STUD WALLS SHOWN AND NOT OTHERWISE NOTED SHALL BE
2X4 STUDS @ 16' 0. C. AT INTERIOR WALLS AND 2X6 0 16* 0. C. AT EXTERIOR
WALLS. TWO STUDS MINIMUM SHALL BE PROVIDED AT THE END OF ALL WALLS
AND AT EACH SIDE OF ALL OPENINGS. TWO 2X8 HEADERS SHALL BE PROVIDED
OVER ALL OPENINGS NOT OTHERWISE NOTED. SOLID BLOCKING FOR WOOD COL-
UMNS SHALL BE PROVIDED THROUGH FLOORS TO SUPPORTS BELOW. WALLS SHALL
HAVE A SINGLE BOTTOM PLATE AND A DOUBLE TOP PLATE. END NAIL TOP PLATE
TO EACH STUD WITH TWO 16D NAILS, AND TOENAIL OR END NAIL EACH STUD TO
BOTTOM PLATE WITH TWO 160 NAILS. FACE NAIL DOUBLE TOP PLATE WITH 16D
AT 12' D.C. AND LAP MINIMUM 4'-0' AT JOINTS AND PROVIDE SIX 16D NAILS
AT 4' D.C. EACH SIDE OF JOINT. ALL STUD WALLS SHALL HAVE THEIR LOWER
WOOD PLATES ATTACHED TO WOOD FRAMING BELOW WITH 16D NAILS AT 12' D.C.
STAGGERED OR BOLTED TO CONCRETE WITH 5/8' DIAMETER ANCHOR BOLTS (WITH
7' MINIMUM EMBEDMENT)@ 4' 0" D.C. UNLESS INDICATED OTHERWISE. INDIVI-
DUAL MEMBERS OF BUILT UP POSTS SHALL BE NAILED TO EACH OTHER WITH
16D @ 12" O.C. STAGGERED. REFER TO THE PLANS AND SHEAR WALL SCHEDULE
FOR REQUIRED SHEATHING AND NAILING. WHEN NOT OTHERWISE NOTED, PROVIDE
GYPSUM WALLBOARD ON INTERIOR SURFACES NAILED TO ALL STUDS, TOP AND
BOTTOM PLATES AND BLOCKING WITH NAILS AT 7* D.C. USE SO COOLER NAILS
FOR 1/2' GWB AND 6D COOLER NAILS FOR 5/8' GWB. WHEN NOT OTHERWISE
NOTED, PROVIDE 1/2' (NOM.) APA RATED SHEATHING (SPAN RATING 24/0) ON
EXTERIOR SURFACES NAILED AT ALL PANEL EDGES (BLOCK UNSUPPORTED EDGES),
TOP AND BOTTOM PLATES WITH 8D @ 6' D.C. AND TO ALL INTERMEDIATE STUDS
AND BLOCKING WITH 8D @ le O.C. ALLOW 1/8' SPACING AT ALL PANEL EDGES
AND ENDS.
C. FLOOR AND ROOF FRAMING: PROVIDE DOUBLE JOISTS AROUND ALL OPENINGS IN
FLOORS OR ROOFS UNLESS OTHERWISE NOTED. PROVIDE SOLID BLOCKING AT ALL
BEARING POINTS. TOENAIL JOISTS TO SUPPORTS WITH TWO 16D NAILS. ATTACH
TIMBER JOISTS TO FLUSH HEADERS OR BEAMS WITH METAL JOIST HANGERS IN
ACCORDANCE WITH TIMBER CONNECTOR NOTE. NAIL
ALL MULTI JOIST BEAMS TO-
GETHER WITH 16D @ 12" D.C. STAGGERED. UNLESS OTHERWISE NOTED ON THE
PLANS, ROOF AND FLOOR SHEATHING SHALL BE LAID UP WITH STRENGTH AXIS
PERPENDICULAR TO SUPPORTS AND NAILED WITH OD NAILS @ 6" D.C. TO FRAMED
PANEL EDGES AND OVER STUD WALLS AS SHOWN ON PLANS AND @ 12' O.C. TO
INTERMEDIATE SUPPORTS. PROVIDE APPROVED PLYWOOD EDGE CLIPS CENTERED
BETWEEN JOISTS/TRUSSES AT UNBLOCKED ROOF SHEATHING EDGES. ALL FLOOR
29019
SHEATHING EDGES SHALL HAVE APPROVED TONGUE AND GROOVE JOINTS OR SHALL
02VAL
BE SUPPORTED WITH SOLID BLOCKING. ALLOW 1/8' SPACING AT ALL PANEL
i2117119
EDGES AND ENDS OF ALL ROOF AND FLOOR SHEATHING. TOENAIL BLOCKING TO
SUPPORTS WITH 16D @ 12' D.C. UNLESS OTHERWISE NOTED. AT BLOCKED FLOOR
j .. .....
AND ROOF DIAPHRAGMS PROVIDE FLAT 2X BLOCKING AT ALL UNFRAMED PLYWOOD
Todd Fisher
PANEL EDGES AND NAIL WITH EDGE NAILING SPECIFIED.
to 206 624 470D a.. 29
Is 2084476971
ffisher@1harriottvalentine.com
P.jed Allilt-
H2D Arahitacture + Design
2302D Edmonds Way #113
Edmonds, WA 98020
P.J..
Whitehead Residence
8802 217th SW
Edmonds, WA 98026
- - ... . ..........
imig PERMIT
12JI3119 REVISIONS 91 1
SIZE
LENGTH
DIAMETER
6D
2-
0. 113"
8D
2-1/27
0. 131*
B.11dilit DIPIft-App.111
IOD
3-
0. 148*
12D
3-1/4'
0. 148"
F
16D
3-1/0
0. 162"
IF CONTRACTOR PROPOSES THE USE OF ALTERNATE NAILS, THEY SHALL SUBMIT
NAIL SPECIFICATIONS TO THE STRUCTURAL ENGINEER (PRIOR TO CONSTRUCTION)
FOR REVIEW AND APPROVAL. NAILS SHALL BE DRIVEN FLUSH TO FACE OF
SHEATHING WITH NO COUNTERSINKING PERMITTED.
25. STAPLES - THE FOLLOWING STAPLES MAY BE SUBSTITUTED FOR NAILING OF
PLYWOOD (APA RATED SHEATHING):
NAIL SIZE EQUIV. STAPLE
MINIMUM LENGTH
6D 16 GA.
1-3/4'
8D 15 GA.
1-3/4'
IOD 13 GA.
1-3/4'
RESUB
OEC 19 2019
BUILDING IDEPARTMENT
Crl'YOFEDMONDS
�'E'N"E`RAL STRUCTURAL
NOTES
...,.a I--
S1.0
X
w
Harriott Valentine
Harri," Valentine Engineers Inc.
1932 First Avanue, Suite 720
Seattle, Washington 98101-2447
tal 200 624 4760 fax 208 447 0971
—haolott�I,ntlnaxona
WA
12117119
p.j.,t—a
To d Fisher
he 206 624 476D a,. 29
fa 206 447 6971
tfisher(Igharriotb,alentIne.com
P.j arhh-
H2D Architecture + Design
2302D Edmonds Way #113
Edmonds, WA 9802G
pe,j..
Whitehead Residence
8802 217th SW
Edneards, WA 9BG26
LEGEND
FOUNDATION PLAN NOTES
I... Ine. Issue D..dptl..
NOTEI! EXISTING FRAMING MEMBERS AS INDICATED ON THIS PLAN ARE
117119 PERMIT
SPAN
1. PERE NEW CONCRETE WALLS OR FOOTING
ASSUMED FOR DESIGN PURPOSES ONLY. HARRIOTT VALENTINE ENGINEERS
—
l2jl3/19 REVO.N. #1
ABUT EX. CONCRETE, PROVIDE DOWELS #4 x
SHALL NOT BE HELD LIABLE FOR LOCATION/ SIZE OF EXISTING MEMBERS
2�—D" TO MATCH HORIZ. REINFORCING, EMBED
AS CALLED ON THIS PLAN. EXISTING MEMBERS SHALL BE VERIFIED AND
EXTENT
5" IN EPDXY GROUT.
REPORTED TO STRUCTURAL ENGINEER OF RECORD PRIOR TO CONSTRUCTION.
ZAX
SECTION DETAIL
2. SEE 6 & 10/S4.0 FOR TYPICAL HOLDOWN
REQUIREMENTS AT CONCRETE WALLS AND
FOOTINGS.
(FB)
FLUSH BEAM
(PT)
PRESSURE —TREATED
3. SLAB —ON —GRADE SHALL BE PLACED AND
CURED FOR A MINIMUM OF SEVEN DAYS
B.11culit DIP1,111m App—
BEFORE RETAINING WALLS ARE BACKFILUED.
COLUMN ABOVE
SEE RETAINING WALL DETAILS FOR SPECIFIC
CONFIGURATION.
RESUB
0
COLUMN BELOW
—
DEC 19 2019
NEW STRUCTURAL WALL
BU IMBDER&MMDES"T
C
EXISTING STRUCTURAL WALL
NEW CONCRETE WALL
ADDITION FLOOR FRAMING & FOUNDATION PLAN
EXISTING CONCRETE WALL
�.o scole: I/e = f-If
NDATION PLAN
D—bg Nu—,
S2.0
w
Ji
-a
LEGEND
FRAMING PLAN NOTES
NOTEH EXISTIN FRAMING MEMBERS AS INDICATED ON THIS PLAN ARE
SPAN
1. SW— INDICATES SHEARWALL TYPE PER
ASSUMED FOR DESIGN PURPOSES ONLY. HARRIOTF VALENTINE ENGINEERS
SCHEDULE 8/S4.0. REFER TO DETAILS FOR
SHALL NOT BE HELD UABLE FOR LOCATION/ SIZE OF EXISTING MEMBERS
TYPICAL SHEARWALL CONSTRUCTION. SEE
AS CALLED ON THIS PLAN. EXISTING MEMBERS SHALL HE VERIFIED AND
<
EXTENT
ARCHITECTURAL DRAWINGS FOR ADDITIONAL
REPORTED TO STRUCTURAL ENGINEER OF RECORD PRIOR TO CONSTRUCTION.
WALL INFORMATION.
SECTION DETAIL
2. REFER TO GENERAL STRUCTURAL NOTES FOR
FLOOR OR ROOF SHEATHING TYPE, THICKNESS,
(FB)
FLUSH BEAM
AND NAILING.
(PT)
PRESSURE —TREATED
3. COLUMNS SHALL BE DOUBLE STUD MINIMUM,
UNLESS NOTED OTHERWISE. SEE 1I/S4.O.
—
COLUMN ABOVE
4. AT ALL SHEARWALLS PROVIDE DOUBLE TOP
0
COLUMN BELOW
PLATES AND SPLICE PER 12/S4.0.
NEW STRUCTURAL WALL
5. POSTS M, INCLUDING ENDS OF WALL OPENINGS,
SHALL BE (2)2x6 UNLESS NOTED OTHERWISE.
EXISTING STRUCTURAL WALL
NEW CONCRETE WALL
ROOF FRAMING PLAN (MAIN FLOOR WALLS)
EXISTING CONCRETE WALL
scale: Ile = 1*-V
EXISTING MASONRY WALL
Harriott Valentine
Ham0ft Valentine Engine,, Inc.
1932 Fire[ Awme, S,1ta 720
Seattle. Washington OB101-2447
tal 206 624 4760 fax 206 447 6971
—hafflothal,rifflne-no
f2117119
P.j . . . . . . .
Todd Fisher
te 206 824 47GO ex. 20
fax 206 447 6971
tfisher@harrioth,alentine.com
-jed—hosd
1-12D Architect— + Design
23020 Edmonds Way #113
Edmonds, WA 98020
Mitehead Residence
88022171 SW
Edmonds. WA 98026
I f7li 9 PERMIT
12ji 3119 REVISIONS #1
13.11ding Dep—ent App—I
RESUB
DEC 19 2019
BUILDING Del—,—Ew
CITY OF EDMONDS
was
ROOF
FRAMING PLAN
n.".n
S2.1
w
w
Harriott Valentine
TC'
CORNER BARS TO MATCH
EXT HORIZ. REINF.
SEE I1/S3.O FOR
N
Halrlol,t Valentine Engine.. In..
AS SHOWN
CALLOUTS IN COMMON
-'OUTLINE
%
WALL BEYOND
1932 First Aven e, gait, 720
Seattle. Washington 98101-2447
DOUBLE
I I I
4x TOP PLATE
PANEL EDGE NAILING PER
'u rL
PRE -MANUFACTURED
tel 206 024 4760 fax 206 447 6971
—h—itnt1�1onfine.oarn
C"L TYPICAL CORNER BARS:
CURTAIN
T [rA
NEW SHEARWALL
::
PLAIN (8d @ Sam U.N.O.)
C
TRUSSES PER PLAN
V
r�ERTS 24
r
24"
24F
CMU WALL PER PLAN
#4 x _F @ 16"oc
BLOCK FULL DE ' PTH
(VENT PER ARCH1.)
(1) #4 NOSING BAR
CORNER BARS TO MATCH
&
/L L
PAVING PER ARCH'
----- 1.
SLAB -ON -GRADE
PER PLAN
LTP4 TO MATCH A35
I A35
SPACING
HORIZONTAL REINFORCING
�4 (ALTERNATE HOOKS)
11
PER SW
W
SCHEDULE
. . . . . .
SINGLE
SHEARWALL PER
PLAN
ADD'L. TYPICAL CORNER BARS:
CURTAIN VERTS. 24
HST3 I S I TRAP -
:1E
241
HALF OF BOLTS AT
TOP OF CMU WALL,
A,,
IULLY GROUT ALL
(2) #4 CONIT.
(HEADER AT SOME
HALF AT WOOD
CELLS OF CMU BLOCK
DRAINAGE PER
LOCATIONS)
- SHEARWALL PER PLAN
TOP PLATE
IN CONTACT WITH
ARCHITECTU
STRAP
TYPICAL CORNER BARS AT CONCRETE WALLS
3/4- = V-0" 2
3/4" = 1'-0" 3
3/4' V-10"
BLOCK ONE TRUSS BAY OUTRIGGERS 2x4 @ 24"oe
SHEARWALL PER PLAN
ER SW SCHEDULE
A35 PER SW SCHEDULE
W/ 26 0 48 oc NTH (3) 16d TO TRUSS
2x6 P ' T. PLATE WITH
T - PLATE WITH
(3) 16d AT BLOCKS
BLOCK ONE JOIST BAY
NCHOR BOLTS PER
5/8"o ANCHOR BOLTS PER
F
FULL -DEPTH 0 48"oc
#4 @ 16'0c VERT.
SW SCHEDULE (@ 48"oc
(ALT. HOOKS)
ELSEWHERE)
(3) 16d -----
FACENAIL
#4 @ 10"oe HORIZ
[(2) AT TOP OF WALL]
PE PL
JOISTS PER PLAN
AT BARGE (5) 12d
lilt
RAFTER
TRUSSES
NOTCH GABLE EN PER PLAN
2E
A 1 .Qf
01VAL
TRUSS OVER WALL
i�ll 7119
FOR OUTRIGGERS
BRACES 20 @ 48"oc,
as
P.1-
Todd Fisher
SHEATHE GABLE E D NO STEEPER THAN 1:1
6
i.77 I
TRUSS TO MATCH SW
o'..
os
Is 206 624 4760 ex. 29
BELOW A34 EACH SIDE OF BRACE
1%. .
fax 208 447 8971
tfisherChard,fivalemine.com
SHEARWALL PER PLAN A35 PER SW SCHEDULE
SEE 7/S3.0 FOR WALL
I'lls A.1,111
A,
AND FOOTING CALLOUTS
DRAINAGE PER ARCH'L_/
v v IV
(2) #4 CONT.
112D Architect— + Design
23020 Edmonds Way #113
A
Edmonds, WA 98020
pra"
3/4" = V-O" 5
3/4" 1'-0" 6
3/4" V-0"
8
Whitehead Residence
8802 217th SW
Edrmmda,WA980W
4" THICK SLAB REINF. W/
D as-01s.
W2.9xW2.9 6x6 W.W.M. CTR'D.
I
BLOCK ONE TRUSS BAY
1 11 IL_
if7lig PERMIT
11113/19
w/2x6 @ 48" Die
TYPICAL 6 MIL VAPOR BARRIER
EX ROOF TRUSSES
(OMIT AT EXTERIOR SLABS)
PER PLAN
SLAB
�E
4" FREE -DRAINING
GRANULAR FILL
NEW ROOF TRUSIEI--\,.
PER PLAN
........ ................
BE�R
J 8
X-_
CONTROL JOINT FORMER
L 6x6x3/8
CONTROL "ZIP STRIP" 11/2" DEEP
INSTALL HORIZ.
RESUB
(JOINT MAY BE SAW -CUT
JOIN T man
(3) 16d AT BLOCKS
LEG OF ANGLE
AT CONTRACTOR'S OPTION)
M 10�
IN BED JOINT
DEC 19 2019
CUT ALT. WIRES AT JOINT
8d @ 3" oc STAGGERED
TOP AND BOTTOM OF
SEE /S3.0 FOR
3/8"0 HILTI HITJ
DFPARTMENT
CrryOFEDMONDS
4 2nd POUR 1st POUR
TOP CHORD WHERE
- I COMMON
HY-200 ANCHORS
PLASTIC JOINT KEY
sm EADOW BURKE"
NEW GABLE END TRUSS
@ 16"ocINSTALLED
WITH CYLINDRICAL
STRUCTURAL DETAILS
CONSTR. STOP REINF.1' CLEAR OF
MEETS EX. TRUSS
MESH SCREENS
JOINT JOINT EACH SIDE
SAWCUT EXISTING
CMU WALL
CMU WALL PER PLAN
.—Ina N.—,
- WOOD FURRING WALL
SLAB -ON -GRADE (NOT INSULATED)
PER ARCH'L
TYPICAL
CMU LINTEL
S3.0
3/4" = V-0" 9
3/4" V-0" 10
3/4" = V-0" I 1
3/4" 1'-0"
12
SHEATHING PER SW
SCHEDULE
ONE-SIDED 1 @1
SHEARWALL
FSHEATHING PER SW
SCHEDULE
TWO—SIDED STAGGER ANCHORS
SHEARWALL AT TWO—SIDED
SHEARWALLS
ANCHOR BOLT WITH PLATE-` SHEATHING PER SW
WASHER PER SW SCHEDULE SCHEDULE
(0.229"x 3" SQUARE)
� TYPICAL SHEARWALL ANCHOR BOLT PLACEMENT
3/4' = V-0" 1-1/2" = 1'-0" 2
HOLDOWN SCHEDULE
MARK
FASTENERS TO STUDS'
ANCHOR
DIA.'
— I--,—
EMBEDMENT LENGTH
lgwll�
_CASI_f�
HDU4
(10) 1/4�O x 21/2' SCREWS
5/8'
121/2"
5'
HDU5
(10) 1/4"0 x 21/2" SCREWS
5/8 *
N/A
5"
/1\
1 . 10d AND 12d DIAMETER = 0.148 ; 16d DIAMETER = 0.162'. SCREWS SHALL
BE SIMPSON "SDS" TYPE SCREWS, INSTALL PER SIMPSON RECOMMENDATIONS.
2. PROVIDE A36 OR A307 ALL —THREAD AT EPDXY AND CAST —IN ANCHORS.
3. PROVIDE SIMPSON "SET—XP* EPDXY PER GENERAL STRUCTURAL NOTES.
SPECIAL INSPECTION IS REQUIRED.
4. AT CAST —IN ANCHORS PROVIDE HEAVY HEX NUT AT BOTTOM OF ALL —THREAD.
HOOKED J—BOLT MAY BE USED FOR LTT HOLDOWNS.
3/4" = 1'-0"
I
(2) STUDS MIN. — REFER
TO PLAN FOR LOCATIONS
WHERE BUILT—UP POST
CONSISTS OF MORE STUDS
S1 FIR PLAN
HOUDOWN PER PLAN W1
SCREWS PER MFR. SPECS.
(OR NAILS SIMILAR)
CONCRETE STEMWALL PER
PLAN (6" MIN. THICKNESS)
AT EX. CONIC. WALL
AT NEW CONCRETE WALL
PROVIDE ALL —THREAD
PROVIDE ALL —THREAD AND
AND EMBED IN EPDXY
HEX NUT OR HEADED BOLT
GROUT PER SCHEDULE
NOTE:
AND EMBED PER SCHEDULE
PROVIDE 5" END
(HOOKED J—BOLT MAY BE
AND 13/4' EDGE
USED FOR LTT HOLDOWNS)
DISTANCE FOR
ANCHORS (MIN.)
TYPICAL HOLDOWN AT CONCRETE
3/4" = V-0" 10
SHEARWALL SCHEDULE (NOT ALL USED ON PLANS)
MARK
SHEATHING'
STUDS AT
ABUTTING
PANEL
EDGES'
PANEL EDGE
NAILING'-'
RIM JOIST OR BLOCKING TO TOP PLATE
BOTTOM PLATE ATTACHMENT
SOLID RIM
TJI RIM
BOTTOM PLATE TO
RIM JOIST BELOW
ANCHORBOLT
TO CONCRETE'
SILL PLATE
AT FOUND.
Swi
15/32' COX PLYWOOD
2x
8d @ 6"oc
A35 @ 24"oc
16d 0 Voc
16d 0 6"oc
5/8"0 @ 48"oc
2x
SW2
15/32- CDX PLYWOOD
2x
Bid 0 4"oc
A35 @ 15'oc
16d @ 4"oc
16d 0 4"oc
5/8"0 @ 32"oc
2x
SW3
1 15/32' COX PLYWOOD
3x
8d 0 3"oc
A35 @ 12"oc
N/A — USE SOLID RIM
16d @ 3"oc
5/8"0 @ 16"oc
2x
SW4
15/32- COX PLYWOOD
3x
8d @ 2"oc
A35 @ 9"oc
N/A — USE SOLID RIM
16d @ 2-oc
5/8"0 @ 12"oc
2x
SW5
15/32' CDX PLYWOOD BOTH SIDES
3x
8d @ 3"oc
A35 0 Voc
N/A — USE SOLID RIM
(2) ROWS 16d @ 3"oc
5/8"0 0 12'oc
SWIS
15/32' COX PLYWOOD BOTH SIDES
3x
8d @ 2"oc
A35 @ 41/2"oc
N/A — USE SOLID RIM
(2) ROWS 16d 0 2"oc
5/8"0 0 12"oc
1. WALL SHEATHING SHALL CONSIST OF APA RATED PLYWOOD WITH SPAN RATING 24/0. ALLOW 1/8" SPACING AT ALL PANEL EDGES AND ENDS OF PANELS. 7/16" APA RATED
SHEATHING (OSB) MAY BE USED IN PLACE OF 15/32- CDX.
2. STUDS AT ABUTTING PANEL EDGES MAY CONSIST OF (2)2x STUDS IN PLACE OF 3x STUDS — NAIL (2)2x STUDS TOGETHER WITH BOTTOM PLATE ATTACHMENT NAILING.
3. BLOCK ALL PANEL EDGES W/ 2x4 FLAT, ATTACH W/ PANEL EDGE NAILING. TWO STUDS MINIMUM ARE REQUIRED AT EACH END OF ALL SHEARWALLS. END STUDS SHALL
RECEIVE PANEL EDGE NAILING. INTERMEDIATE STUDS SHALL BE 2x STUDS. NAIL SHEATHING TO INTERMEDIATE FRAMING MEMBERS WITH 8d @ 12"oc.
4. 8d NAILS SHALL BE 0.131" DIAMETER x 21/2" (COMMON). 16d NAILS SHALL BE 0.135" DIAMETER x 31/2" (BOX).
5. ANCHORS TO CONCRETE SHALL CONSIST OF CAST —IN —PLACE ANCHOR BOLTS, EXPANSION BOLTS, EPDXY GROUTED ALL —THREADS, OR TITEN HD HEAVY DUTY SCREW ANCHORS.
CAST —IN —PLACE ANCHOR BOLTS HAVE A 7' EMBED AND SHALL BE J—BOLTS OR SHALL HAVE A HEX NUT AT THE BOTTOM END. EXPANSION BOLTS SHALL HAVE 5" EMBED AND
SHALL NOT BE USED AT STEM WALL LOCATIONS WIT� EDGE DISTANCE LESS THAN 5- (INSTEAD, USE EPDXY GROUTED ALL —THREADS OR TITEN HD ANCHORS). EPDXY GROUTED
ANCHOFS §HALL HAVE 5" EMBED AND 21/2" MIN. EDGE DISTANCE. TITEN HD ANCHORS SHALL HAVE 31/2" EMBED AND 13/4" MIN. EDGE DISTANCE. AT ALL ANCHOR BOLTS,
PROVIDE STEEL PLATE WASHERS THAT ARE A MINIMUM OF 0.229" (3 GAUGE) x Yx 3" (SIMPSON BP5/8-3 OR SIMILAR). PLACE BOLTS PER ANCHOR BOLT PLACEMENT DETAIL.
SHEARWALL PER PLAN PANEL EDGE NAILING BLOCKING (OR JOIST) BOTTOM PLATE NAILING
PER SW SCHEDULE
PER SW SCHEDULE PER FLOOR AND ROOF
DETAILS
NAILING TO MATCH "'�—NAILING TO MATCH JOISTS PER PLAN
B rOM PLATE NAILING S
OT BOTTOM PLATE NAILING (DIR. VARIE
PER SW SCHEDULE PER SW SCHEDULE
PANEL EDGE NAILING FULL DEPTH BLOCKING TOP PLATE CONNECTION
SHEARWALL PER PLAN PER SIN SCHEDULE (OR RIM AT EXTERIOR) PER SIN SCHEDULE
PANEL EDGE NAILING
SIEARWAII PER PLAN /—NAILING TO MATCH BLOCK ALL PANEL EDGES--E PER SW SCHEDULE
BOTTOM PLATE NAILING
PER SW SCHEDULE ANCHOR BOLTS & WASHERS
SILL PLATE PER SW PER SIN SCHEDULE
SCHEDULE PANEL EDGE NAILING
INTERSECTING PANEL EDGE NAILING PER SW SCHEDULE
NON—SHEARWALL PER SIN SCHEDULE
TYPICAL SHEARWALL INTERSECTIONS TYPICAL SHEARWALL SECTION
3/4" = V-0" 8
TYPICAL DOUBLE TOP PLATE
ILAN
MULTI —STUD PER PLAN WITH
NAILING PER GEN. NOTES
TYPICAL MULTIPLE -STUD POST CONSTRUCTION
3/4" = V-0"
(8) 16d 0 4"oc STAGGERED
EACH SIDE OF SPLICE
(16d @ 12"oc ELSEWHERE)
rUD
1 6'-0" MIN. BETWEEN SPLICES I
TYPICAL TOP PLATE SPLICE CONSTRUCTION
3/4" = 1'-0" 12
Harriott Valentine
Harriett Valentina Engineers In,
1932 First Ae, Suite 720
Seattle, Washington 98101-2447
lei 206 624 4760 fox 205 447 6971
hmdoth�alentihe.corn
WA
290-19
2117119
J.� .......
Todd Fisher
to 208 624 4760 ex. 29
Is 206 447 6971
[I1$har@hardofiMIeAII
'nueet—n-
1121) Architecture + Design
23020 Edmonds Way 0113
Edmonds, WA 98020
P.J..
Whitehead Residence
8802217t SW
Edmonds, WA 98026
Its. D.t. 41.
117/19 PERMIT
12`13/19
i o.p.n.- app I
RESUB
DEC 19 2019
I ILDIING DE E
'u CnOFE ONDS
...no liu.
STRUCTURAL DETAILS