BLD2019-0184*6-11 Type: RESIDENTIAL BLDG Subtype: NEW SINGLE FAMILY Owner/ Business: PINE STREET VIEWS LLC; LOT 3 Status: ISSUED Parcel No: Site Address: 917 PINE ST EDMONDS, Subdivision: Lot: Fire Sprinklers: No Lot Area: 35 Zoning: RS-8 Valuation: $513,258.50 Occupancy Type: SFIR IRC Construction Type: VB Code Edition: 2015 No. Stories: 2 # of Dwelling Units: 1 Applied: 2/21/2019 Issued: 3/10/2020 Final: Expiration Date: 3/p/2-0"21 Issued by: NED Scope of Work: NEW SFR, PLUMBING AND MECHANICAL INCLUDED WA State Contractor L & I #: fairwdl977mt City of Edmonds Business License #: 602454996-001-0001 NAME TYPE NAME CONTACTS ADDRESS PHONE PPLICANT A C PINE STREET VIEWS U-C 13110 NE 177TH PL #194, WOODINVILLE WA98072 (206)949-2223 CONITRACTOR CT PINE STREET VIEWS LLC 13110 NE 177TH PL #194, WOODINVILLE WA 98072 (206)949-2223 STIcVE@FAIRWINDSDEVELOPMENT.CI3 M OWNER 13 PINE STREET VIEWS LLC; LOT 13110 NE 177TH PL #194 ' WOODI NVI LLE WA 98072 (206)949-2223 STIEVEOFAIRWINDSDEVELOPMENT.CI3 [MT111 DESCRIPTION FEE ACCOUNfz! INFORMATION AMOUNT N I PAID B-BUILDING PERMIT FEE 001.000.322.10.000.00 $3,570.00 B-BUILDING PLAN REVIEW FEE 001.000.345.83.000.00 I $2,950.00 $2,950.00 2/21/19 REC075509 B-MECHANICAL PERMIT FEE 001.000.322.10.000.00 $275.00 B-PLUMBING PERMIT FEE 001.000.322.10.000.00 $316.00 B-STATE BUILDING CODE SURCHARGE 001.000.237.150 $6.50 ENGINEERING INSPECTION FEE 001.000.341.82.000.00 $900.00 ENGINEERING INSPECTION FEE 001.000.341.82.000.00 $100.00 ENGINEERING REVIEW FEE 001.000.341.82.000.00 $90.00 FIRE/AID SIGN FABRICATION FEE 111.000.68.542.64.31.00 $75.00 PARK IMPACT ADMIN FEE 001.000.322.10.000.00 $50.00 PARK IMPACT FEE 332.100.345.85.000.00 $2,734.05 STORMWATER GENERAL FACILITY CHARGE COM/MF 422.000.379.00.000.00 $799.00 TRAFFIC IMPACT ADMIN FEE 001.000.341.82.000.00 $50.00 TRANSPORTATION IMPACT FEE 112.502.345.86.000.00 $4,561.37 TRANSPORTATION IMPACT FEE 112.502.345.86.000.00 $1,687.77 X-TECHNOLOGY FEE 001.000.321.99.100.00 $35.00 TOTALS: $18pl99.69 $2,950.00 Printed: Tuesday, March 10, 2020 1:01:42 PM 1 of 3 40% RESIDENTIAL BLDG Permit City of Edmonds PERMIT NUMBERi 121 Sth Ave N, Edmonds WA 98020 BLD2019-0184 www.edmondswa.gov 425.771.0220 tb'NDITI.'Oki�Pi NOTES Applicant, on behalf of his or her spouse, heirs, assigns, and successors in interests, agrees to indemnify defend and hold harmless the City of Edmonds, Washington, its Hold Harmless officials, employees, and agents from any and all claims for damages of whatever nature, arising directly or indirectly from the issuance for this permit. Issuance of this permit shall not be deemed to modify, waive or reduce any requirements of any City ordinance nor limit in any way the City's ability to enforce any ordinance provision. Final approval on a project or final occupancy approval must be granted by the Building Occupancy Official prior to use or occupancy of the building or structure. Check the job card for all required City inspections including final project approval and final occupancy inspections. Any request for alternate design, modification, variance or other administrative deviation (hereinafter "variance") from adopted codes, ordinances or policies must be specifically requested in writing and be called out and identified. Processing fees for such request shall be established by Council and shall be paid upon submittal and are non-refundable. Permit Disclaimer Approval of any plat or plan containing provisions which do not comply with city code and for which a variance has not been specifically identified, requested and considered by the appropriate city official in accordance with the appropriate provision of city code or state law does not approve any items not to code specification. Sound/Noise originating from temporary construction sites as a result of construction activity are exempt from the noise limits of ECC Chapter 5.30 only during the hours of Sound/Noise 7:00am to 6:00pm on weekdays and 10:00am and 6:00pm on Saturdays, excluding Sundays and Federal Holidays. At all other times the noise originating from construction sites/activities must comply with the noise limits of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120. INSPECTIONS "T OMPLETE 'D SEQID INSPECTION TYPE INSPECT RESULT. NOTES DATE B-2 FOOTINGS B-2 SLAB INSULATION B-3 GAS PIPING TEST B-3 MECH ROUGH IN B-3 PLUMB GROUND WK B-3 PLUMB ROUGH IN B-3 UNDERFLR FRAMING B-4 DRYWALL FASTENING B-4 FRAMING B-4 HEIGHT VERIFICATION B-5 INSULATION ENERGY B-2 RETAINING WALL B-3 ROOF SHEATHING B-4 CEILING GRID B-4 DRYWALL FASTENING B-4 FIRESTOPPING E-2 TESC AND MOBILIZE Printed: Tuesday, March 10, 2020 1:01:42 PM 2 of 3 RESIDENTIAL BLDG Permit City of Edmonds PERMIT NUMB 121 Sth Ave N, Edmonds WA 98020 BLD2019-0184. www.edmondswa.gov /.425.771.0220 . ..... ...... . E-3 STRM TIGHTLINE B-2 FOUNDATION DRAIN B-2 FOUNDATION WALL ROW CURB POST SWR MAIN INSTALL E-3 STRM MGMT FACILITY E-3 STRM COVENANT E-4 WATER SERVICE LINE A-1 BUILDING PRECON B-1 SETBACKS B-3 STUCCO B-4 INTERIOR SHEAR X-3 BUILDING FINAL" X-2 ENGINEERING FINAL B-7 BUILDING OTHER INSP E-5 DRIVEWAY SLOPE Printed: Tuesday, March 10, 2020 1:01:42 PM 3 of 3 WATER A, METER RECORD City of Edmonds PERMIT NUMBE4'4`,�] E�j 121 Sth Ave N, Edmonds WA 98020 ENG2019-0228 www.edmondswa.gov / 425.771.0220 JOB INFORMATION WATER METER SIZE: TSSUED: 03/10/2020 SITE ADDRESS: 917 PINE ST EDMONDS IRRIGATION ONLY: FIRE SPRINKLING: APARTMENT/CONDO UNITS: CONTACTS NAME TYPE NAME ADDRESS PHONE APPLICANT FAIRWINDS DEVELOPMENT 13110 NE 177TH PL #194, Woodinville WA 98072 CONTRACTOR FAIRWINDS DEVELOPMENT 13110 NE 177TH PL #194, Woodinville W-A 98072 OWNER PINE STREET VIEWS LLC 13110 NE 177TH PL #194, EDMONDS WA 98020-3949 FEE INFORMATION DESCRIPTION AMOUNT PAID PAID DATE 1" WATER METER FEE $2,970�00 3/4" WATER GENERAL FACILITY CONNECTION $S,050.00 PUBLIC WORKS -UTILITY BILLING INFORMATION METER NUMBER: REGISTER NUMBER: METER LOCATION: BRAND: INSTALLATION DATE: INSTALLED BY: SERVICE MATERIALISIZE: READ AFTER ADDRESS: BILLING ACCOUNT NO: ROUTE: ADDITIONAL INFORMATION: Fire Sprinkling THIS DOCUMENT IS NOT VALID UNTIL FEES ARE PAID AND THE CITY ENGINEER OR HIS/HER DEPUTY HAS SIGNED BELOW RELEASED BY DATE Printed: Tuesday, March 10, 2020 1:06:14 PM 1 of 1 ------------ SECrION 2!j �.-27N R.3E., w.m. A DE Ripn E PROPER 1 fRtC0ADPV5 AV. WV4M.1,15 AID AV. HAIVIV2M) 2 4 LOT LLG- gfLSCRIPTIONS PMCEL 2 or EIIIIIvAIN j IL 86C. AV, 0 It 4 C(71 Or E AV DYANSO) PARUX 3 two r I wrB L- - - - - - - - -ili?:STREET, R-PRE boT p1ne- s BENCH MARK '7/ 57 L,67 -MLITY NOTE s4 -lv b6 deivolWYJ VICINITY MAP APPLICANT ENGINEER/SURVEYOR PARCEL NUMBER WATER SIERVICE —.1— PROPERTY AREA . . ll� ..., — POLICE PROTECTION P.— PROPERTY ADDRESS .1 — —11 VllwuUlt—o:�. . ZONING FIRE PROTECTION TELEPHONE 7�—_— '1��ILARY,SEWER SERVICE '9 ELECTRICITY UA�RAL GAI col PRELIMINARY SHORT PLAT FOR NLI/4 5LG. 25, T.27N., R.3E,,W.M. CITY OF EDMONDS Y, WAS HINGTON SNOHOMISH COUNT LSR AZV�-,M.- 5 �77-101-17 q� 5- pi M t:::� 'Z;-7 C) ?� --2�00 1 1 6 � (.001 0�) Ct L t BUILDING PERMIT APPLICATION Development Services Building Division ,e N / Edmonds, WA 98020 425 771 n2on s, permit status and inspection ru Lu. iittp://www.edmondswa.gov/ JOB SITE INFORMATION/LOCATION: (Where the work is taking place) Job Site Address: 917 Pine Street Parcel: 27032500105500 Lot /Unit/Suite #: Subdivision: Rec#201810085001 PROPERTY OWNER: Name. Pine Street Views LLC Mailing Address: 13110 NE 177th P1. #194 City/State/Zip: Woodinville, WA 98072 Phone #: 206-949-2223 Email: steve@fairwindsdevelopment.com OWNER INSTALLATION: *If yes, read and sign* Will work be performed by the property owner? 0 Yes IR No I own, reside in, or will reside in the completed structure. This installation is being made on property that I own which is not intended for sale, lease, rent, or exchange according to RCW 18.27.090. Owner Signature: APPLICANT/ CONTACT INFORMATION: Name of Applicant: Steve Nielsen Mailing Address: 13110 NE 177th P1. #194 City/State/Zip: Woodinville, WA 98072 Phone #: 206-949-2223 E-mail: steve@fairwindsdevelopment.com GENERAL CONTRACTOR: (if different from applicant) General Contractor: Fairwinds Development LLC Mailing Address: 13110 NE 177th P1. #194 City/State/Zip: Woodinville, WA 98072 Phone #: 206-949-2223 E-mail: Fairwinds@FairwindsDevelopment.com WA STATE CONTRACTOR L & I # (CCB) & EXPIRATION DATE: FAIRWDL977MT 12/4/2019 CITY OF EDMONDS BUSINESS LICENSE #: C) 9 =Flerrm,�iit#: TYPE OF PERMIT (Provide • Accessory Structure/ Detached Garage Details on Page 2) 0 Addition • Demolition 0 Mechanical IR New Single Family / Duplex 0 Plumbing E3 Fire Sprinkler 0 Remodel El New Commercial/ Mixed Use 0 Re -Roof El Signs 0 Tank El Tenant Improvement El Other Remodel Permit fees are based on: The value of the work performed. Indicate the value (rounded to the nearest dollar) of all equipment, materials, labor, overhead, and the profit for the work indicated on this application. Valuation: PROPOSED NEW SQUARE FOOTAGE FOR THIS APPLICATION Basement scl ft: Finished K Unfinished E3 Ist Floor, sci ft: 1653 2nd Floor, sq ft: 2153 Garage/Carport:, scl ft: 780 Deck/Covered Porch/Patio: 820 other sci ft: PROJECT DESCRIPTION A Construct one single family residence. T_ liv- I A I certifV that the information I have provided on this form/application is true, correct and complete, and that I am the property owner or duly authoril:ed agent of the property owner to submit a permit application to the City of Edmonds. Print Nanyb: Signature: Date GENERAL COMMERCIAL DATA Occupancy Group(s): Occupant Load(s): Type(s) of Construction: Fire Sprinklers: Yes El No El WA STATE ENERGY CODE: If your project affects the building envelope, mechanical systems, and/or lighting, you must complete the appropriate WSEC forms. DEFERRED SUBMI17ALS: All commercial building permits that will require associated plumbing, mechanical, fire sprinkler, and/or fire alarm permits are applied for separately. TI / CHANGE OF USE / NEW BLDG: Include TRAFFIC IMPACT worksheet MECHANICAL EQUIPMENT COUNTS (New and Relocated) BTUs Gas Elec Other Qty A/C Unit /Compressor Air Handier /VAV Boiler I Dryer Duct Exhaust Fans 7 Fireplace 45 1 Furnace 100 1 Heat Pump Unit Hydronic Heating 195 1 Roof Top Unit (Provide eleva- tions if a Commercial Bldg) PLUMBING FIXTURE COUNTS (New, Relocated or re -piped) Qty Qty Clothes Washer I Tub/ Showers 3 Dishwasher Backflow Device (RPBA, DCDA, AVB) 1 Drinking Fountain Pressure Reduction/ Regulator Valve Floor Drain/Sink 1 Refrigerator Water Supply 1 Hose Bibs 2 Water Heater - Tankless? Y or N 1 Hydronic Heat 1 Water Service Line 1 Sinks 7 Other: Toilet 3 Other: GAS/FUEL CONNECTION COUNTS (New, Relocated or re -piped) BTUs Qty BTUs Qty A/C Unit Outdoor BBQ/ Fire pit Boiler Stove/Range/Oven 40 1 Dryer Water Heater A Fireplace/ Insert Other: 45 1 Furnace Other: '100 1 MEDICAL GAS, AIR VACUUM COUNTS (New, Relocated or re -piped) QtY Qty Carbon Dioxide Nitrous Oxide Helium Oxygen Medical Air Other: Medical - Surgical Vacuum Other: DEMOLITION 71- Type of structure to be demolished: Square footage of structure to be demolished: AHERA Survey done? Y/N PSCAA Case #: Critical Areas Determination: Study Required 11 Conditional Waiver EJ Waiver El Fill in Place El Fill Material: Removal 13 size of Tank (Gallons) Critical Areas Determination: Study Required El Conditional Waiver El Waiver D GRADE/FILL/EXCAVATE Grading: Cut cubic yards Fill cubic yards Cut/ Fill in Critical Area: Yes 11 No El GENERAL PROVISIONS APPLICATIONS: Applications are valid for a maximum of 1 year. ESLHA Applications, 2 years. LICENSING: All contractors and subcontractors are required to be licensed with Washington State Department of Labor & Industries and have a current City of Edmonds Business License, City of Edmonds Critical Area Notice of Decision Applicant: Property Owner: P-'rit ipws LuQ'- Critical Area File 4: Permit Number: 'I-6Lb a L-) � 9 1 eH Site Location: P;'ne S�- Parcel Number: o)-70-S,9!&00 I 0,T50 0 Project Description: U—\ 1�— F-I Conditional Waiver. No critical area report is required for the project described above. I . There will be no alteration of a Critical Area or its required buffer. 2. The proposal is an allowed activity pursuant to ECDC 23.40.220, 23.50.020, and/or 23.80.040. 3. The proposal is exempt pursuant to ECDC 23.40.230. Erosion Hazard. Project is within erosion hazard area. Applicant must prepare an erosion and sediment control plan in compliance with ECDC 18.30. Fj Critical Area Report Required. The proposed project is within a critical area and/or a critical area buffer and a critical area report is required. A critical area report has been submitted and evaluated for compliance with the following criteria pursuant to ECDC 23.40.160: I The proposal minimizes the impact on critical areas in accordance with ECDC 23.40.120, Mitigation sequencing; 2. The proposal does not pose an unreasonable threat to the public health, safety, or welfare on or off the development proposal site; 3. The proposal is consistent with the general purposes of this title and the public interest: 4. Any alterations permitted to the critical area are mitigated in accordance with ECDC 23.40.110, Mitigation requirements. 5. The proposal protects the critical area functions and values consistent with the best available science and results in no net loss of critical functions and values; and 6. The proposal is consistent with other applicable regulations and standards. F-I Unfavorable Critical Area Decision. The proposed project is not exempt or does not adequately mitigate its impacts on critical areas and/or does not comply with the criteria in ECDC 23.40.160 and the provisions of the City of Edmonds critical area regulations. See attached findings of noncompliance. F-I Favorable Critical Area Decision. The proposed project as described above and as shown on the attached site plan meets or is exempt frorn the criteria in ECDC 23.40.160, Review Criteria, and complies with the applicable provisions of the City of Edmonds critical area regulations. Any subsequent changes to the proposal shall void this decision pending re -review of the proposal. Conditions. Critical Area specific condition(s) have been applied to the permit number referenced above. See referenced pen -nit number for specific condition(s). F� Notice on Title. Critical area notice on title recorded under AFN Reviewer L2& a.# Signature - qA; I -mg Date Appeals: Any decision to approve, condition, or deny a development proposal or other activity based on the requirements of critical area regulations may be appealed according to, and as part of, the appeal procedure, if any, for the permit or approval involved. Revised I I � 29 2016 r CITY OF EDMONDS 1215 1h Avenue North, Edmonds WA 98020 Phone: 425.771.0220 # Fax: 425.771.0221 - Web: www.edmondswa.gov DEVELOPMENT SERVICES DEPARTMENT * PLANNING DIVISION 'Ile. I is 9%J Critical Area Determination (CRA20170084) Based on a review and inspection of the subject site, staff has determined that one or more critical areas are located on or near the site. Critical areas are ecologically sensitive or hazardous areas that are protected in order to maintain their functions and values. Site Location 921 Pine Street Tax Account Number 27032500105500 Property Owner Estate of L. Joan Demeroutis Applicant Fairwinds Development Critical Area(s) Present El Wetlands (ECDC23.50) 0 Frequently Flooded Areas (ECDC 23.70) M Geologically Hazardous Areas (ECDC 23.80) M Erosion Hazard Areas EJ Londslide Hazard Areas F-1 Seismic Hazard Areas El Fish & Wildlife Habitat Conservation Areas (ECDC 23.90) D Streams Site Description During review and inspection of the subject site, it was found that the site contains critical areas, including Geologically Hazardous Area (Erosion Hazard), pursuant to Chapter 23.80 of the Edmonds Community Development Code (ECDC). The associated LiDAR map indicates that a west -facing slope runs across the subject site. Soils on the site are identified as Alderwood Urban Land Complex, 2-8% slopes. The slope drops approximately 24-feet over a horizontal distance of 220-feet, approximately a 10.9% grade. Portions of the slope exceed 15% grade. Slopes in excess of 15% grade are categorized as potential Erosion Hazard Areas. The site does not contain any known wetlands, fish and wildlife habitat conservation areas, or streams. 0. IN What does this mean? The critical area regulations are only triggered when an alteration is proposed to a critical area or its buffer. However, once an alteration in or near critical area Is proposed, critical area studies and City review and approval may be required. What is an 'Alteration'?, According to Section 23.40.005 of the Edmonds Community Development Code (ECDC): "Alteration" means any human -induced action which changes the existing conditions of a critical area or Its buffer. Alterations include, but are not limited to: grading, filling; dredging; draining; channelizing; cutting, pruning, limbing or toppin& clearing, relocating or removing vegetation; applying herbicides or pesticides or any hazardous or toxic substance; discharging pollutants; paving, construction, application of gravel; modifying for surface water management purposes; or any other human activity that changes the existing landforms, vegetation, hydrology, wildlife or wildlife habitat value of critical areas. Brad Shipley, Associate Planner June 26, 2017 Wa-me, rh(� lignature Date Cited sections of the Edmonds Community Development Code (ECDC) con be found at http://Www.codepublishing.comlWAIEdmonds Environmentally Critical Areas General Provisions (ECDC 23.40) Wetlands (ECDC 23.50) Frequently Flooded Areas (ECDC 23.70) Geologically Hazardous Areas (ECDC' 23.80) Fish and Wildlife Habitat Conservation Areas (ECDC 23.90) City of Edmonds GIS map tool with approximate location of critical areas: http://Mops.edmondswa.gov Page 12 U City of Edmonds CRA20170084 3u.V eel WGS_I 984_Web-Vercator_Auxiliary-Sphere 'Z, C-ty of Edmords This map is a user generated static output from an Internet mapping site and is for -eference only Data lavers that appear on this mao may or may rot be accurate, current. or otherwise reliaDle. THIS MAP IS NOT TO BE USED FOR DESIGN OR CONSTRUCTION Legend Creeks B Seismic Hazard Areas Earth Subsidence and Landslide J L Minimum Buffer Adjacent to Hai Wetlands Wetlands Boundary Welland Boundaries Not Completel Welland Known Extents Floodpiains Contour Lines 2 10,50 — 100 Landslide Hazard Area 40% Severe Erosion Hazard 15%-40% Erosion Hazard Areas 15%-40% ArcSDE.GIS.STREET-CENTERLINE' �all other �alues> 1 2 5; 4 9: 71: 7; 8 Notes .UYV 4TP20 Critical Areas File #:C—RA 9W7 003 '-/ 11 Initial Determination - $100 qSubsequent Determination - $50 Date Received: b —I Date Mailed to Applicant: The purpose of this checklist is to enable City staff to determine whether any critical areas and/or buffers are located on or adjacent to the subject property. Critical areas, such as wetlands, streams and steep slopes, are ecologically sensitive or hazardous areas that are regulated to protect their functions and values. The City's critical area regulations are contained within Edmonds Community Development Code (ECDC) Chapters 23.40 through 23.90. C� Property Owner's Authmization City of Edmonds Development Services Department Planning Division Phone: 425.771.0220 www.edmoiidswa.gov /4C. A property owner, or an authorized representative, must fill out the checklist, sign and date it, and submit it to the City. Staff will review the checklist, conduct a site visit, and make a determination of whether there are critical areas andlor critical area buffers on or near the site. If a "Critical Area Present" determination is issued, a report addressing the applicable critical area requirements of ECDC Chapters 23.40 through 23.90 may be required depending on the scope of the proposed activity. By my signature, I certify that the information and exhibits herewith submitted are true and Correct to the best of my knowledge and grant my permission for the public officials and the staff of the City of Edmonds to enter the subject property for the purposes of inspection attendant to this application. The undersigned owner, and his/her/its heirs, and assigns, in consideration on the processing of the application agrees to release, indemnify, defend and hold the City of Edmonds harmless from any and all damages, including reasonable attorney's fees, arising from any action or infraction based in whole or part upon false, ir�sleading, inaccurate or incomplete information fuirlished by the applicant, his/her/its agents or employees. - Z-) .41 SIGNATURE OF OWNER DATE Im r-W- b Owner: L�zf�- -L� Name . e??- I �2)1,4 ��t� T Street Address -1� &f—J VfZ:2 City State Zip Applicant/Agent: Name \i E N� I E Ll�e-&; L-, f 16 /J C- 1-7 JI-b Lf Street Address LA 111 ILAAF- VIA - City State Zip Telephone:- 0'V L, -qlil - ��f22� Telephone: c7 L4 9 1 V2- Z Em ai I ad d re s s: - ULX-�T-W f ZC- M i L L4 1-0 r,� Email Address: -,TZ�JE 0-1 F�Ateuoioa�. 6� 1\1 g�4 L-. 6- tvn Revised on 114117 P20 - Critical A reas Checklist Page] of2 -1 CAFileNo: Ckuo�lwg'( R20 Critical Areas Checklist Site Information 1. Site Address/ Location: CN-1 T2jA_�'_6t1ZC--ST E C�\,J C5 2. Property Tax Account Number: 3. Approximate Site Size (acres or square feet): ('70 S45 J�-,-r 4. Is this site currently developed? 9 Yes 0 No If yes, how is the site developed? �:71L�L_c r—AMILN �k�A e 5. Describe the general site topography. Check all that apply, Flat to Rolling, No slope on/adjacent to the site or slopes generally less than 15% (a vertical rise of 10-feet over a horizontal distance of 66-feet). D Moderate: Slopes present on/ adjacent to site of more than 15 % and less than 40% (a vertical rise of 10-feet over a horizontal distance of 25 to 66-feet). 0 Steep: Slopes of greater than 40% present on/ adjacent to site (a vertical rise of 10-feet over a horizontal distance of less than 25-feet). 6. Have there been landslides an or near the site in the past? EDYes ZNo If yes, please describe: 7. Site contains areas of year-round standing water? 0 Yes (approx. depth: KNo 8. Site contains areas of seasonal standing water? 0 Yes (approx. depth: 4No If yes, what season(s) of the year? 9. Site is in the floodway or floodplain of a water course? 0 Floodway 0 Floodplain Nk�' 10. Site contains a creek or an area where water flows across the grounds surface? 0 Yes X No If yes, are flows year-round or seasonal? 0 Year-round 0 Seasonal (time of year: 11. Obvious wetland is present on site? 1J_ Yes gNo ------------- - ------------------------------------------- For City Staff Use Only--- 1. Zoning: 9 S - 46 3, SCS mapped soil type(s): AI,JDIF A-iAvoc. a (4 it-19 A,-J t-Ael Ck j2t )k 3, Critical Areas inventory or C.A. map indicates Critical Area on site: 510,-J d -A Z 2tA_J� 4. Site within designated North Edmonds Earth Subsidence and Landslide Hazard Area (ESHLA)? 140 DETERMINATION CR -PICAL AREAS PRESENT WAIVER Reviewed by: Date: Revised on 114117 P20 - Critical A reets Checklist Page 2 of 2 I Simple Heating System Size: Washington State This heatina system sizing calculator is based on the Prescriptive Requirements of the 2015 Washington State Energy Code (\NSEC) and ACCA Manuals J and S. This calculator will calculate heating loads only. ACCA procedures for sizing cooling systems should be used to determine cooling loads. The glazing (window) and door portion of this calculator assumes the installed glazing and door products have an area weighted average U-factor of 0.30. The incorporated insulation requirements are the minimum prescriptive amounts specified by the 2015 WSEC. Please fill out all of the green drop -downs and boxes that are applicable to your project. As you make selections in the drop -downs for each section, some values will be calculated for you. If you do not see the selection you need in the drop -down options, please call the WSU Energy Extension Program at (360) 956-2042 for assistance, PrDject Information Contact Information 917 PINE STREET ROD NOVION- NOVION GROUP INC 8634B 3RD AVE NW SEATTLE, WA. 98117 Heatinci System Type: (1) Ali Other Systems Heat Pump To see detailed instructions for each section, place your cursor on the word 'Instructions". Design Temperature Instructions Design Temperature Difference (AT) 46 Ed=n& AT= Indoor (70 degrees) -Outdoor Design Temp Area of Building Conditioned Floor Area Instructions Conditioned Floor Area (sq ft) 3.8067 Average Ceiling Height Conditioned Volume ln�tructions Average Ceiling Height (it) 10.01 38,060 Glazing and Doors U-Factor X Area UA Inntructions 0.30 1,214 364.20 Skylights U-Factor X Area UA Instructions 0.50 Insulation Attic U-Factor X Area UA Instructions Select R Value w, No selection Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA Instructions R 38 Vented 7�1 0.027 2.153 58.13 Above Grade Walls (see Fig. i) U-Factor X Area UA Instructions R 21 Inivemediale ... 0.056 2,066 115.70 Floors U-Factor X Area UA Instructions R 38 -;71 0.025 47.50 Below Grade Walls (am Figure 1) U-Factor X Area Instructions Select R value No selection Cv Slab Below Grade (see Figure i) F-Factor X Len2!t_, UA Instructions select - cond . t�o - n . vic; No selection Slab on Grade (see Flaure v In--tructions - F-Factor 0.360 X Length 80 Aft— IV k R 10 Fu,y Insulated IV Location of Ducts FEB 2 1 2019 Instructions Uncondilicined Space Figure 1. Ab.�. Grade uct as age loe11Ic ant 1.10 r�" N .3ull Sum of UA 614.33 Envelope Heat Load 28,259 Btu I Hour SumofUAXAT Air Leakage Heat Load 18,908 Btu/Hour V01UmeX 0.6XATX.018 Building Design Heat Load 47,167 Btu/Hour Air Leakage + Envelope Heat Loss Building and Duct Heat Load 51,884 Btu/ Hour Ducts in unconditioned space Sum of Building Heat Loss X 1. 10 Ducts in conditioned space: Sum of Building Heat Loss X I Maximum Heat Equipment Output 72,638 Btu I Hour Building and Duct Heat Loss X 1. 40 for Forced Air Furnace Building and D�t Heat Loss X 1.25 for Heat Pump &Z 0 18 14 (07101113) 917 PINE STREET 2015 WASHINGTON STATE ENERGY CODE AND 2015 INTERNATIONAL RESIDENTIAL CODE RESIDENTIAL ENERGY AND VENTILATION SUBMITTAL FORM Applicant: ROD NOVION Job Type: El New Application #: 0 Addition 0 Remodel Date: 02.04.2019 Conditioned Square Feet: 3,806 SF Occupancy: M Single Family /Duplex 11 Residential Care / Assisted Living / Adult Family Home MINIMUM INSULATION REQUIREMENTS - These may need to be increased based on ENERGY CREDITS selected below. Rafter/Joist All Walls Walls Floors Over Slab Glazing U-Factor Door Vaulted Other Above Below Unheated On Vertical Overhead U-Factor Ceilings Ceilings Grade Grade Space G rade R-10 Cl Exterior OR 0.30 0.50 0.30 R-38 R-49 or R-21 R-15 Ct Interior 5R R-30 R-10 R-38 ADV INT R-5 CI + R-13 Bati OR R-21 Batt w/TB (a-,) Slab Equivalent U-Factor 0.30 0.50 I 0.30 0.026 0.026 0.056 0.042 0.029 N/A PROPOSED 0.28 0.28 R-38 R-21 R-38 R-10 ADV = Uncorn pressed R-38 Over Top Plates& Entire Ceiling Area INT= 2x6 at 16" o.c. w/R-10 Headers C1 =Continuous Rigid Insulation TB=ThermalBreak ENERGY CREDITS - See the Energy Credits descriptions on the back of this form and indicate which options will be used. Small Addition 0.5 pts required. (Additions < 500 s.f.) Small Dwelling Unit / Medium Addition 1.5 pts required (Dwellings < 1,500 s.f. w/ glazing < 300 s.f., or Additions < 1,500 s.f.) Medium Dwelling Unit / Large Addition 3.5 pts required (All Dwellings not Small or Large, or Additions > 1,500 s.f.) 3. 5 PTS Large Dwelling Unit 4.5 pts required (Dwellings > 5,000 s.f) TOTAL POINTS = - I@ la (0.5 pts) 0 lc (2.0 pts) 0 2a (0.5 pts) 0 2c (1.5 pts) 11 3b (1.0 pts) 0 3d (1.0 pts) 0 5a (0.5 pts) 0 5c (1.5 pts) 116 (0.5 pts) 0 lb (1.0 pts) 0 ld (0.5 pts) 11 2b (1.0 pts) Ea 3a (1.0 pts) 0 3c (1.5 pts) 0 4 (1.0 pts) 0 5b (1.0 pts) 0 5d (0.5 pts) VAPOR RETARDERS - Select the Vapor Retarder to be used at each location. CRAWLSPACE 0 6-mil Black Poly 0 31/2" Concrete Slab 0 N/A (No Crawl Space) FLOORS 0 4-mil Poly 0 Face Stapled Backed Batts 0 Ext. T&G Plywood M 6-mil Poly (Slab On Grade Floor) WALLS 0 4-mil Poly 0 Face Stapled Backed Batts 0 Vapor Barrier Primer* 0 N/A R-3.75 Rigid On Wall Exterior) CEILINGS 0 4-mil Poly 12 Face Stapled Backed Batts - * Perm Rating!s 1.0] 0 Vapor Barrier Primer* D N/A (1/150 Ventilation) 0 N/A R- 10 Rigid Above Roof Deck) 0 N/A R- 10 Spray Below Roof Deck) VENTILATION SYSTEM - Select a System Type and complete the Ventilation Rate calculation on the back of this form. 11 Not Applicable (Additions less than 500 s.E) VENTILATATION RATE 90 CFM 01 Whole -House Exhaust Fan with fresh air port (net 4 sq. in. minimum opening) at each habitable room. A timer operates an exhaustfan which pulls outside air through air inlets located in each habitable room. EX Integrated System with fresh air duct connected to return air duct of forced -air heating system. A timer operates thefurnace blower and a motorized outside air inlet damper to distribute outside air through the heating ducts. 0 Supply Fan with fresh air duct connected to supply air duct or return air duct of forced -air heating system, or other ducts. A timer operates a supplyfan connected to an outside air inlet to distribute outside air through the heating ducts or other ducts. 0 Heat Recovery System. A timer operates a heat recovery ventilator (HR V) to distribute outside air to habitable rooms through dedicated ducts. 0 Designed System per IMC with calculations and/or performance testing. Includes: 0 Whole -house fan 0 Fresh air ports Typically such systems must be designed, installed, tested, and balanced by a mechanical engineer or other HVA C professiona,� Continuously operating ventilation systems shall provide the minimum flow rates specified in Table M1507.3.3(l). Intermittently operating ventilation systems shall provide flow rates per Table MI 507.3.3(l) as modified by Table MI 507.3.3(2). AIR TESTING - These tests must be performed on -site with specialized equipment. 23 Duct Leakage Test Required when space -conditioning equipment is installed, altered, or replaced (including replacement ofair handler, outdoor unit ofair conditionerlheatpump, cooling or heating coil, orfurnace heat exchanger). Some exceptions apply. Building Leakage Test Requiredfor additions > 500 sf and new construction. VENTILATION SYSTEM SIZING - Complete the Ventilation Rate calculation below. Table M1507.3.3(l) is based on continuous operation. The ventilation rate must be increased by the factors from Table M1507.3.3(2) if the system Will operate less than 24 hours per day, as follows: Ventilation System Airflow Rate Requirement from Table M1507.3.3(l) 90 - cfm Ventilation Rate Factor from Table M1507.3.3(2) VENTILATION RATE 90 cfm TABLE M1507.3.30) CONTINUOUS WHOLE -HOUSE MECHANICAL VENTILATION SYSTEM AIRFLOW RATE REQUIREMENTS DWELLING UNIT NUMBER OF BEDROOMS FLOOR AREA (square feet) 0-1 2-3 6-7 >7 Airflow In CFM <11,500 30 45 60 75 90 1,501 - 3,000 45 60 75 90 105 3,001 - 4,500 60 75 90 105 120 4,501 - 6,000 75 90 105 120 135 6,001 - 7,500 90 105 120 135 150 >7,500 105 120 135 150 65 TABLE M1507.3.3(2) INTERMITTENT WHOLE -HOUSE MECHANICAL VENTILATION RATE FACTORSa, b RUN-TIME PERCENTAGEIN EACH 4-HOUR 25% 33% 50% 66% 75% 100% SEGMENT Factora 4 1 3 2 1.5 1.3 1.0 a. For ventilation system run time values between those given, the factors are permitted to be determined by interpolation. b. Extrapolation beyond the table is prohibited. TABLE M1507.3.6.2 PRESCRIPTIVE SUPPLY FAN DUCT SIZING Supply Fan ested CFM at 0.40" W.G. Specified Volume from Table M1507.3.3(l) Minimum Smooth Duct Diameter Minimum Flexible Duct Diameter 50-90 CFM 4 inch 5 inch 90-150 CFM 5 inch 6 inch 150-250 CFM 6 inch 7 inch 250-400 CFM 7 inch 8 inch ENERGY CREDIT DESCRIPTIONS o qualify for these credits the building permit drawings shall specify the option(s) selected a shall specify all requirements. OPTION DESCRIYrION PTS OPTION DESCRWTION PfS la EFFICIENT BUILDING ENVELOPE Prescriptivecompliance is basedon Table O�5 3c b HIGH EFFICIENCY FIVAC EQUIPMENT: Closed -loop ground source heat pump; with a 1.5 R402. 1.1 with the followng moditications: Vertical fenestration U = 0,28, Fluor R-38, Slab minimum COP of 3.3 OR Open loop wst� source beat pump with a nuecimurn pumping on grade R-I 0 peruncler and under crane slab, Below grade slab R- I'D perimeter and under hydraulic head of 150 fee and minim= COP of 16 entire slab OR Compliance 1:ased on Section R402.1.4: Reduce the Total UA by 5%. lb EFFICIENT BUILDING ENVELOPE: Prescriptive compliance is based on Table 1.0 3dU HIGH EFFICIENCY HVAC EQUIPMENT: Ductless Split System Heat Pumps, Zonal 1.0 R402.1.1 with the following modifications: Vertical fenestration U = 0,25, Wall R-21 plus Control� In homes where the primary space heating system is zonal electric heating, a ductless R-4 CL Floor R-38, Basement wall R-21 int plus R-5 Cl, Slab on grade R-10 perimeter and heat pump system shall be installed and provide heating to the largest zone ofthe housing unit. turder entire slab, Below grade slab R-10 perimeter and under entire slab OR Compliance I based on Section R402.1 4: Reduce the Total UA by 15%. 1 c EFFICIENT BUILDING ENVELOPE: Prescriptive compliance is based car Table 2.0 4 HIGH EFFICIENCY HVAC DISTRIBUTION SYSTEM: All heating and cooling system 1.0 R402. 1.1 with the following modifications: Vertical fenestration U = 0.22, Ceiling and components installed inside the conditioned space, All combustion equipment shall be direct single -rafter or joist-vauked R-49 advanced, Wood finime wall R-21 int plus R-I 2 CI, Floor vent or sealed combustion For forced air ducts: A maxim= of 10 linear feet ofreturra ducts R-38, Basement wall R-21 irt plus R-12 Cl, Slab on grade R-10 perimeter and under entire and 5 linear feet of supply ducts my be located outside the conditioned space All metallic slab, Below grade slab R-10 perimeter and under entire slab OR Compliancis based on ducts located outside the conditioned space must have both transverse and longitudinal joints Section R402 1 4: Reduce the Total UA by 30%. sealed with raistic. If flex ducts are used, they cannot contain splices. Flex duct connections must be made with nylon maps and installed using a plastic stropping tensioning toot Ducts located outside the conditioned space must be insulated to a minimum ofR.8. Locating system components in conditioned crawl spaces is not permitted under this option. Electric resistance heat and ductless lost pumps are not permitted under this option. Direct combustion heating ecur . pment with AFUE less than 80% is not mantled under this option. I do EFFICIENT BUILDING ENVELOPE: Prescriptive compliance is based on Table 0.5 5a EFFICIENT WATER HEATIN& All showerhead and kitchen sink faucets installed in the 0.5 R402. Ll with the following modifications: Vertical fenestration U = O�24 house shall he rated at 1. 75 GPM or ]�� All other lavatory faucets shall be rated at 1.0 GPM or less. 2a AIR LEAKAGE CONTROL AND EFFICIENT VENTILATTOM Compliance based on 0.5 5b EFFICIENT WATER HEATING: Water heating system shall include am ofthe following: 1.0 R402.4.1.2: Reduce the lested air leakage to 3,0 air changes per hour maximum AND All Gas, propane or oil water heaterwilh a minanum EF ofO.74 OR Water heater heated by whole home ventilatien requirements as determined by Section MI 5073 ofthe ground source beat pump meeting the requirements ofOption 3c. Interiantronal Residential Code shall be met with a high efficiency fan (maximum 0 35 watts/cfffi), not interlocked with the furnace fort Ventilation systems using a furnace including im ECM motor are allowed, provided that they are controlled to operate at low speed in ventilation only moce. 2b AIR LEAKAGE CONTROL AND EFFICIENT VEbITILATION: Compliance based on 1.0 5c EFFICIENT WATTR HEATING: Water heating system shall include one ofthe following: 1-5 Section R402.4.1.2 Reduce the tested air leakage to 2,0 air changes per how m,viinium Gas, propane or oil water heater with a minimum EF ofO,91 OR Solar water heating AND All whole house ventilation requirements as determined by Section M1 507.3 ofthe supplementing a minimum standard water heater. Solar water heating will provide a rated Intennational Residential Code shall be met with a heat recovery ventilation system with minanum savings of 85 therms or 20W kWh based on the Solar Rating and Certification minimum sensible heat recovery efficiency of O�70. Corporation (SRCC) Annual Performance ofOG-300 Certified Solar Water Heating Systems OR Electric hem pump water heater with a mininium EF of2,0 and meeting the standards of NEEA's Northern Climate Specifications for Heat Pump Water Heaters. 2c AIR LEAKAGE CONTROL AND EFFICIENT VENTILATION: Compliance based on 1.5 5d EFFICIENT WATER HEATING: A drain water heat recovery umt(s) shall be installed, tTch 0.5 Section R402.4. L2: Reduce the tested air leakage to 1.5 air changes per how maximum captures waste water heat from all the showers, and has a minimum efficiency of401/6 if AND All whole house ventilation requirements as determined by Section MI 507.3 ofthe installed for equal flow or a mimmum efficiency ol`520% if installed for unequal flow. Such units lnte�tronal Residential Code shall be met with a heat recovery ventilation system with shall be rated in accordance with CSA B55.1 and be so labeled. minimum semilite heat recovery efficiency ofO.85. 3aE HIGH EFFICIENCY HVAC EQUIPMENT: Gas, propane or od-fited fumace with 1.0 6 RENEWABLE ELECTRIC ENERGY: For each I200kWh ofelectricalgenerationper 0.5 minimum AFUE of 94%, OR Gas, propane or oiled -fired boiler with minimum AFU`E of housing unit provided annually by on -site wind orsolar equipment a 0.5 credit shall beallowed, 921/. up to 3 credits. Generation shall be calculated as follows: For solar electric system, the design shall be demonstnited to meet this requirement using the National Renewable Energy 3b HIGH EFFICIENCY HVAC EQUIPMENT: Air -source heat pump with minimum HSPF 1.0 of9.0 Laboratory calculator PVWATTs. Documentation noting solar access shall be included on The plans, For wind generation projects designs shall document annual power generation based an the following factors: The wind turbine power ctuve; average annual wind speed at the site; frequency distribution ofthe wind speed at the site and height ofthe tower. a Projects using this option my not use Option I a, I b, or I c. b. Projects may only include credit from one space heating option, 3a, 3b, 3c, or 3d. W'hen a housing unit has two pieces of equipment (i.e two furriaces) both must meet the standard to receive the credit. Last Modified 7/1/16 Prescriptive Energy Code Compliance for All Climate Zones in Washington Project Information Contact Inforn7ation 917 PINE STREET ROD NOVION- NOVION GROUP INC 8634B 3RD AVE NW SEATTLE, WA 98117 This project will use the requirements of the Prescriptive Path below and incorporate the the minimum values listed. In addition, based on the size of the structure, the appropriate number of additional credits are checked as chosen by the permit applicant. Authorized Representative All Climate Zones R-Value' U-Factor' Fenestration LI-Factorb n/a 0.30 Skylight U-Factor n/a 0.50 Glazed Fenestration SHGC6," n/a n/a Ceilingk 44 0.026 Wood Frame Wall g7n 21 int 0.056 Mass Wall R-Value' 21/2, h 0.056 Floor 309 &029 Below Grade Wallc-m 10/15/21 int + TB 0.042 Slab d R-Value & Depth 10, 2 ft n/a *Table R402. 1,1 and Table R402.1.3 Footnotes included on Page 2. Date h dwelling unit in a residential building shall comply with sufficient options from Table R406.2 so as to achieve following minimum number of credits: 1. Small Dwelling Unit: 1.5 credits Li Dwelling units less than 1500 square feet in conditioned floor area with less than 300 square feet of fenestration area. Additions to existing building that are greater than 500 square feet of heated floor area but less than 1500 square feet. F112. Medium Dwelling Unit: 3.5 credits All dwelling units that are not included in #1 or #3. Exception: Dwelling units serving R-2 occupancies shall require 2.5 credits. LJ3. Large Dwelling Unit: 4.5 credits Dwelling units exceeding 5000 square feet of conditioned floor area. Additions less than 500 square feet: .5 credits Table R406.2 Summary Option Description Credit(s) la Efficient Building Envelope la 0.5 lb Efficient Building Envelope lb 1.0 Ic Efficient Building Envelope 1c 2.0 Id Efficient Building Envelope ld 0.5 2a -Air Leakage Control and Efficient Ventilation 2a 0.5 2b Air Leakage Control and Efficient Ventilation 2b 1.0 2c Air Leakage Control and Efficient Ventilation 2c 1,5 3a High Efficiency HVAC 3a 1.0 3b High Efficiency HVAC 3b 1.0 3c High Efficiency HVAC 3c 1,5 3d High Efficiency HVAC 3d 1.0 4 High Efficiency HVAC Distribution System 1.0 5a Efficient Water Heating 5a 0.5 5b Efficient Water Heating 5b 1.0 5c Efficient Water Heating 5c 1.5 5d Efficient Water Heating 5d 0.5 6 Renewable Electric Energy 0.5 Total Credits *Please refer to Table R406.2 for complete option descriptions 0.5 L Ll 1.0 0.5 Ll E 1.5 F-1 kwh 0.0 3.50 Table R402.1.1 Footnotes For SI: 1 foot .= 304.8 mm, ci .= continuous insulation, int .= intermediate framing. " R-values are minimums. U-factors and SHGC are maximums. When insulation is installed in a cavity which is less than the label or design thickness of the insulation, the compressed R-value of the insulation from Appendix Table A101.4 shall not be less than the R-value specified in the table. b The fenestration U-factor column excludes skylights. The SHGC column applies to all glazed fenestration. c "10/15/21.+TB" means R-10 continuous insulation on the exterior of the wall, or R-15 on the continuous insulation on the interior of the wall, or R-21 cavity insulation plus a thermal break between the slab and the basement wall at the interior of the basement wall. "10/15/21.+TB" shall be permitted to be met with R-13 cavity insulation on the interior of the basement wall plus R-5 continuous insulation on the interior or exterior of the wall. "10/13" means R-10 continuous insulation on the interior or exterior of the home or R-13 cavity insulation at the interior of the basement wall. "TB" means thermal break between floor slab and basement wall. d R-10 continuous insulation is required under heated slab on grade floors. See R402.2.9.1. e There are no SHGC requirements in the Marine Zone. f Reserved. g Reserved. h Reserved. I The second R-value applies when more than half the insulation is on the interior of the mass wall. j Reserved. k For single rafter- or joist -vaulted ceilings, the insulation may be reduced to R-38. I Reserved. M Int. (intermediate framing) denotes standard framing 16 inches on center with headers insulated with a minimum of R-10 insulation. a Nonfenestration U-factors shall be obtained from measurement, calculation or an approved source or as specified in Section R402.1.3. SECTION 2b, T.Z/N., W.M. 40 BENCH MARK Top OF BRASS DISK AT THE INTERSECTION OF 9th AVENUE S. AND PINE STREET. ELEVATION ; 100.00 DATUM : ASSUMED T.B.M. TOP OF NORTHERLY BOLT ON FIRE HYDRANT LOCATED FEET NOTH OF THE SOUTHWEST PROPERTY CORNER LEGAL DESCRIP-noN EN-nRE PROPERDI _C_ P .. B S-OR L T No S -9= RECORDED UNDER -_ A OF CITY OF EQ- DS ; �40HCIWI;H Ty. N( RECORDING .. 111-21-13. REC-11 OF . GTON. BEING A THE NORTHEAST . PORnON OF THE NORTHWEST QUARTER OF ARTER OF SECTION 25. UTILITY NOTE TOWNSHIP 27 NORTH, RANGE 3 EAST, W.M. THE LOCATION OF UNDERGROUND UTILITIES SHOWN HEREON IS APPROAMATE ONLY. THIS SURVEY DOES NOT PURPORT TO SHOW THE THE TOGETHER WITH LOT A. CITY OF EDMONDS LOT LINE ADJUSTMENT NO. LL-2006-100, RECORDED HNOER AUDITOR",FILE 'NO. 200609115184, REACTOERIGS OF SNOHOMISH COUNTY. NGTO BEING PORT, N OF THE NORTHWEST OU R OF THE NORTHEAST LOCATION OF ALL UTILITIES, THE OWNER SHOULD CONTACT PURVEYORS OF ALL UTILITIES IN THE AREA TO DETERMINE THE WASH QUAp7g OF SECTION 25. TOWNSHIP 27 NORTH. RANGE 3 EAS". W.M.; LOCATION AND DEPTH OF ALL UTILITIES ON AND ADJACENT TO THE PROPERTY. SITUATE IN THE COUNTY OF SNOHOMISH. STATE OF WASHINGTON. A MINIMUM OF X SEPARATION IS REQUIRED BETWEEN THE DRY UTILITIES (POWER, GAS. PHONE, CABLE, ETC.) AND SEWER. WATER. AND STORM: b. THE REQUIREMENT OF 10' HORIZO14TAL SEPARATION FROM WATER AND SEWER. 3. T14E CONTRACTOR SHALL BE RESPONSIBLE FOR THE SEWER TAP AND INSTALLATION OF SEWER LATERAL "THIN THE ROW. 4. THE CONTRACTOR SHALL FIELD VERIFY PIPE SZE AND INVER OF EIGSTING SEWER LATERAL AND ADJUST SLOPE OF THE NEW SEWER LATERAL ACCORDINGLY. 5. NOT USED. 6. LOCATION OF THE LANDSCAPE IRRIGATION BACKFLOW ASSEMBLY SHALL BE IDENTIFIED (IF ONE IS PROPOSED). 7. THE 6' CLEANOUT AT THE PROPERTY LINE SHALL HAVE A 12" CAST IRON LAMPHOLE COVER WITH 1/2' HEXBOLTS. THE EASTING SIDE SEWER WLL NEED TO BE TVd By WE CONTRACTOR AND VEDIO MUST BE SUBMITTED 70 THE CIT, REVIEW AND APPROVAL TO RE -USE. 9. IF THE DOSTING SEWER LATERAL IS PROPOSED TO BE REL4 0TyS PUBLIC WORKS DEPARTMENT WILL NEED TO TV THE_V To DETERMINE IF IT IS ACCEPTABLE TO RE -USE, CONTACTILEMONDS PUBLIC WOWS SEWER DIVISION. 425-771-0235, 70 SCHEOU STANDARD DETAIL SS-200 Ir — — — WITH NLUT I— OR -M � PUFMIDSE UNION NIP, X M " eN,_ V&vE OLM ST� � TO � eER-4440 M I' FINK, m "AlIE SMOUE TO � 1011 0 �PXVED � CARSON 1324 01801 WTH =�MVE/ M�N IC27W4% "W W= tIWN KAM 000ft IN AgD �: � � �1_12 (' USE, � � PAMM r X 4? ST� W IT 14 &A VINT, � � TANMN Cr� M � "'P` `—Y 'CV) Tu W a 'E"" AND "'­E S*MU 0 3/4 * W V RUXL RVM � 0200� M MN'e M C`A� W� MTM We" SDNICE Te NME. INSIXLED BY QIINEIt/CWMW= (M KMOK OOM , � := NI,TER �a;w I' THI—IN WILL SUPPLY " 'RewsE. IF AT THE INSPECTION. 10. ALL FINAL RESTORATION SHALL BE COMPLETED BY THE CONTRACTOR. EIVED 11. A MINIMUM OF Ig* OF VERTICAL CLEARANCE IS REQUIRED 9-RECE SEWER AND STORMWATER LINES AT CROSSINGS. 12, INSTALL A STORZ ADAPTER ON THE FIRE HYDRANT. AUG 0 2 2018 PLN20170033 BUILDING APPROVED FOR CONSTRUC-TION _84411. CITY OF EDMONDS aTy 00NEEMM DIVISM m/a/mS . %�- - 3 .-l.' . —UNUS WAMR4 SERVICE INSTAULATION PUBUC WORKS STANDARD ffWA DEPARTMENT DET AJL - 13 0 APPROVED BY, X EIRIM WATER, SEWER AND UTILITY PLAN FOR FAIRWINDS DEVELOPMENT SP IN NW1/4, NE1/4 SEC. 25, T.27N., R.3E.,W.M. CITY OF EDMONDS SNOHOMISH COUNTY, WASHINGTON REVISED PER CITY REVIEW COMMENTS, DAM �20-18 07/10/18 fi"% Lovell—Sauerland & Associates, Inc. s— rol Enonem/StWveyon/pl�ere/D"elOPMMt Con3UItantS C6 L E a-nmil, infogl9aenIgineering.com - vet, lmevVneering.com 19217 36th AmenUe W-, Suite 106 - wod, VA 98MB . 1421)775-1191 T_ I.- ,T.T. 1 777 1 1 "139. P-v I ' - 1-59'77-0-17 1-7 Loi 3 FINAL DRAINAGE REPORT Revision #1 FOR Fairwinds Development LLC at 921 Pine Street Edmonds, Washington 98020 July 2 017 January 2018 March 2018 July 2018 Prepared By: 0'2� X0W K 0r. W A �8,;. '� �V 4 2-0 . �iL C fc, b _ V N AL A It '\ John Yuen, P.E. MAR 2 8 20 BUILDING Lovell-Sauerland & Associates, Inc. 1921736 1h Ave. W., Suite 106 Lynnwood, Washington 98036 LSA FILE No: 5677 71 -.� /��l V u3pv , 7117 11;j a FINAL DRAINAGE REPORT Revision #1 FOR RAE-fN Uejvj��o A/L I - 2018 DE vetopmktg C0t11VjEf8jERV1C'ES Fairwinds Development LLC at 921 Pine Street Edmonds, Washington 98020 July 2 017 January 2018 March 2018 July 2018 r-repared.By: John Yuen, P.E. ,IV - COMPLIES WITH APPLICABLE CITY ST RMWW CODE �iim go LM �1110 N E jnffian0pLjCA%T Copy Lovell-Sauerland & Associates, No 19217 361h Ave. W., Suite 106 Lynnwood, Washington 98036 01:J LSA FILE No: 5677 ON Fairwinds Development LLC Introduction: This summary report provides engineering site design information for the proposed short plat permit application for the development at 921 Pmie Street. The property is located in the Northeast 1/4 of Section 25, T 27 N, R 3 E, W.M. Applicant: Site Address: Steve Nielson 921 Pine Street Fairwinds Development LLC Edmonds, WA 98020 1311 ONE 177h Place Woodinville, WA 98072 Tax Parcel Numbers: 27032500105500 TABLE OF CONTENTS SECTION TABLE OF CONTENTS A- Project Summary B. Vicinity/Parcel Map, Aerial Photo, Watershed Basin Map & Soils Classification Map C. Stormwater System Methodology D. Grading and Erosion Control Summary E. Operation and Maintenance APPENDICS A. Geotechnical Reports Lovell-Satterland and Associates Final Drainage Report —RI LS4 No.5677 L.MIR 921 Pine Street July 2018 Lovell-Saiterland and Associates Final Drainage Report—R.1 LSA No.5677 Section A Project Summary L.M.C1 921 Pine Street July 2018 PROJECTSUMMARY. The project site consists of about 26,170 square feet of land and is currently occupied by a single family residence located in the eastern half of the project site. The vegetation primarily consists of lawn, with trees of varying sizes located around the existing house. The site is bordered by single family lots to the north and east, while 9b Avenue S. borders the site's western boundary and Pine Street borders the southern boundary. Access to the site is from Pine Street via two existing asphalt driveways. The site generally slopes away from east at approximately 2 to 8% towards the west. Runoff from the site sheet flows in the same directions, towards both 9' Avenue S and Pine Street, with no signs of a defined channel. Existing Features Summary: a. Site Area ........................................................................................... 26,170 square feet b. Offsite tributary area: Negligible lawn area from the north c. Soil Types: Alderwood—Urban Land Complex, 2 to 8 percent slopes - Hydrologic Group "B" The proposed project is to redevelop and subdivide the site by removing the existing structures and constructing three (3) new single family houses and associated site paving totaling approximately 12,169 square feet of new and replaced impervious area. Access will be provided by the proposed driveways located at the southern boundary of the site. Landscaping and grass lawn will sui-round significant portions of the new houses and will stabilize the site upon building construction. Seethe submitted civil construction plans for the proposed developments. Summary of Project Minimum Requirements: The project is classified as Category 2 Site Preject, and is subject to Minimum Requirements #1 through # 9. 5.1 Minimum Requirement #1 — Preparation of Stormwater Site Plan. The proposed site development consists of disturbing approximately 0.6 acres of land and creating approx.dimately 12,169 square feet of impenious surfaces by constructing three (3) new single family residences and associated site paving. The project is classified as a Category 2 Site Project, perthe City's classification system, as it involves over 5,000 square feet of new and replaced impervious surfaces. A site development plan has been prepared and is submitted along with this report. 5.2 Minimum Requirement #2 — Construction Stormwater PollutionPrevention. A summary of the site's proposed grading and erosion control measures along with a grading estimate are included in section D. Grading and Erosion Control Summary. The quantities for short plat improvements grading are estimated to be 175 cubic yard of cut and 175 cubic yard of fill. The total site disturbance area of the project is less than one acre, thus a formal Notice ofIntent application for NPDES coverage will not be made to the Department of Ecology. LoveXSauerland and Associates Final Drainage Report -RI LSA No. 5677 L'=W-W �W-v 921 Pine Street Jidy2018 � J 5.3 Minimum Requirement #3 — Source Control ofPolludon. No extraordinary measures are required for the proposed single family residences as the pollution generating impervious surfaces (PGIS) associated with the project are below the 5,000 square feet threshold. .5.4 Minimum Requirement #4 —P�reservation ofNaturalDrainage Systems and Oinfalk The site currently sheet flows towards both 9' Avenue S and Pine Street. The project proposes to infiltrate stormwater runoff onsite, to the maximum extent practicable, reducing the site's impact on the downstream drainage system. 5.5 Minimum Requirement #5 — Onsite Stormwater Management A drainage plan is developed for all new plus replaced hard surfaces, and land disturbed in reference of Low Impact Development Performance Standard using List 92 On -site Stormwater Management BMPs (see ECDC 18.30.060.D.5.e). Lawn and Landscaped Areas Post -Construction Sod Quality and Depth (BMP T5.13) - This BUT will be used for all areas subject to clearing and grading that have not been covered by impervious surface. ..I Roofs Full Dispersion (BMP T5.30) - Due to the site constraints, a native vegetation flowpath length of 100 feet cannot be achieved, therefore, full dispersion is considered infeasible. Downspout Ful I Infiltration Systems (BMP T5. I OA) — The soils condition on -site was determined to be Sands with Gravels, the long-terin infiltration rates were determined to be 7.5, 1.8 and 3.8 inches per hour for Lot 1, 2 and 3, respectively (see Appendix A for Geotechnical / Infiltration Addendiun prepared by Dennis M. Bruce, P.E.). The Downspout Full Infiltration System is proposed for the project. Through a collection of pipes, catch basins and downspout connections, the site's roof surfaces will be collected and routed to infiltration trenches or drywells, all located onsite. Other Hard Surfaces Full Dispersion (BMP T5.30) - Due to the site constraints, a native vegetation flowpath length of 100 feet cannot be achieved, therefore, full dispersion is considered infeasible. Permeable Pavement — Where infiltrating water below the new permeable pavement area would threaten proposed below grade basements (lots 2 and 3). Permeable pavement is considered infeasible. Through a collection of pipes and catch basins, the site's pavement surfaces will be collected and routed to infiltration trenches or drywells, all located onsite. Lovell-Sauerland and Associates 921 Pine Street Final Drainage Report-R.1 July 2018 LSA No.5677 5.6 Minimum Requirement #6 — Runoff TreatmenL Less than 5,000 sf of pollution generating impervious surfaces are proposed (3,314 square feet of asphaltjoint access/concrete driveways), thus no additional on -site stormwater treatment will be necessary per ECDC 18.30.060.D.6. 5.7 Minimum Requirement #7 — Flow ControL Not Applicable. Minimum Requirement 45 is met. 5.8 Minimum Requirement #8 — WetlandProtection. No wetlands are known to exist on or adjacent to the site. 5.9 Minimum Requirement #9 — Operation andMaintenance. An operation and maintenance summary is provided in section E. Love&Saiierland and Associates 921 Pine Street Final Drainage Report -RI Ju�y 2018 LSA No.5677 Section B VicinitylParcel Map, Aerial Photo, Watershed Basin Map & Soil Classification Map Lovell-Sauerfand and Associates Final Drainage Report -RI LSA N6.5677 921 Pine Street July 2018 ,jj, City of Edmonds Vicinity/Parcel Map -71 > rn 00 CY) 101 00 102f 1 mA 3,05 9 8 -1 21416 t 980, t14 Q8 9804 0 CY, 00 a- 4 2 15 2�& 9210 a, C"4 v-1 24 PINEST (-4 rn cc C:k 71 21628 3 1017 21630 1: 2,257 0 I0 94.04 188.1 Feet This map Is a user generated static output from an Internet mapping site and is reference Data !ayer, that appear 'his '-nap may �'. not be &CCL;r WGS-1984-Web-Mercator-Auxiliary-Sphere current, or otherwise relia t', City of Edmonds THIS MAP IS NOT TO BE USED FOR DESIGN OR CONSTRUCTI Legend Notes I I L j, I I' ,*, City of Edmonds Aerial Photo WG5-1984-Web-Mercato r-Auxi 1 ia ry-Sphere 9', City of Edmonds This map Is a user generated static output from an Internet mapping site and is for reference only. Data layers that appear on this map may or may not be accurate, current, or otherwi5e reliable. THIS MAP IS NOT TO BE USED FOR DESIGN OR CONSTRUCTION Legend Art:SIDIE.131S.STREET CENTERLINE! -all other values� 1 2 5; 4 9: 71; 7; 8 Notes I L_ I 11abarger ShettCreek Lovell-Sauerland and Associates Final Drainage Report-R I LSA N6.5677 'k Watershed Basin Map L.NR Cr 921 Pine Street July 2018 Ac 205 2071 21 7th 2; Aldervood Urban land complex, 2-8 I%t, slopes es Aldet,,,.,00d Urban land complex, 8-15 % slop Soils Classification Map Lo vell-Satteriand and Associates 921 Pine Street Final Drainage Report R I July 2018 LSA No. 5677 Section C Stormwater System Methodology Lovell-Sauerland and Associates 921 PineStreef Final Drainage Report —RI July 2018 LSA No. 5677 I.SFI STORMWA TER SYSTEM 3MTHODOLOGY. Based on the recommendations of the Project Geotechnical Engineer, Dennis M. Bruce, P.E., (see enclosed reports in Appendix A), infiltration facilities have been proposed. VVVVHM2012 was used to size the facilities, based on the recommended design infiltration rates, to infiltrate 100% of the site impervious runoff directed to the trenches and drywells. The WWHM2012 reports are included in this Section Lot I - An infiltration trench (41) is proposed at the southwest comer of the lot runoffs from the roof surface and the concrete driveway/walkway will be collected and routed to the trench. Overflow would occur out of the top of catch basin (CB #2) to Pine Street. Lot 2 — Two infiltration trenches (92A along the western property line & #213 along the southern property line) are proposed. Runoff from the north half of roof surface (1,339 square feet) will be collected and routed to the trench 92A. The remaining portion of the roof surface (1, 126 square feet), the concrete driveway (952 square feet) and the wulkway (15 square feet) will be collected and routed to the trench #2B. Lot 3 - Two drywells (93A & #3B) are proposed along the western property line. The north drywell (#3A) receives runoff from the roof surface; and the south drywell (#3B) receives runoff; from the concrete driveway/walkway, and as well as the asphaltjoint access. An overflow pipe system connecting to the storm drain system in Pine Street is pro-vided for Lots 2 & 3. The following table summarizes the proposed infiltration facilities: Facilitv # Contributing Area (0) Infiltration Rate (in/hr) Depth (ft) Length/Width (ft) Infiltration Trench 91 3,914 7.5 3.0 28.0n.0 Infiltration Trench 42A 1,339 1.8 2.0 37.0/4.0 Infiltration Trench #2B 2,093 1.8 2.0 32.0/8.0 Drywell 93A 3,022 3.8 2.5 16.0/14.0 Drywell 93B 1,801 3.8 2.5 12.0/12.0 Lovell-Satterland and Associates 921 Pine Street Final Drainage Report —RI July 2018 LSA No. 5677 Infd'tration Trench #1 Lovell-Sauerland and Associates 921 Pine Street Final Drainage Reporl—ki July 2018 LSA No.5677 L.=Cm WWHM2012 PROJECT REPORT Project Name: Infiltration Trench - Lot 1-R1 Site Na : LSA #5677 Site Address: 921 Pine Street city : Edmonds Report Date: 1/14/2018 MGS Regoin : Puget East Data Start : 1901/10/1 Data End : 2058/09/30 DOT Data Number: 03 Version Date: 2017/04/14 Version : 4.2-13 Low Flow Threshold for Poc 1 : 50 Percent of the 2 Year High Flow Threshold for POC 1: 50 year PREDLVELOPED IJ= USE Name : Basin I Bypass: No GroundWater: No Pervious Land Use acre C, Forest, Mod .09 Pervious Total 0.09 Impervious Land Use acre Impervious Total 0 Basin Total 0.09 Element Flows To: Surface MITIGATED LAND USE Name Basin 1 Bypass: No GroundWater: No Interflow Groundwater Pervious Land Use acre Pervious Total 0 Impervious Land Use acre ROOF TOPS FLAT 0.075 DRIVEWAYS MOD 0.015 Impervious Total 0.09 Basin Total 0.09 Element Flows To: Surface Interflow Groundwater Gravel Trench Bed 1 Gravel Trench Bed 1 Name : Gravel Trench Bed 1 Bottom Length: 28.00 ft. Bottom Width: 7.00 ft. Trench bottom slope 1: 0 To I Trench Left side slope 0: 0 To 1 Trench right side slope 2: 0 To 1 Material thickness of first layer: 3 Pour Space of material for first layer: 0.3 Material thickness of second layer: 0 Pour Space of material. for second layer: 0 Material thickness of third layer: 0 Pour Space of material for third layer: 0 Infiltration On Infiltration rate: 7-5 Infiltration safety factor: I Total Volume Infiltrated (ac-ft.): 33.812 Total Volume Through Riser (ac-ft.): 0.001 Total Volume Through Facility (ac-ft.): 33.813 Percent Infiltrated: 100 Total Precip, Applied to Facility: 0 Total Evap From Facility: 0 Discharge Structure Riser Height: 3 ft. Riser Diameter: 6 in. Element Flows To: Outlet 1 outlet 2 Gravel Trench Bed Hydraulic Table Stage(feet) Area(ac.) Volume(ac-ft.) Discharge(cfs) Infilt(cfs) 0.0000 0.004 0.000 0.000 0.000 0.0444 0.004 0.000 0.000 0.034 0.0889 0.004 0.000 0.000 0.034 0.1333 0.004 0.000 0.000 0.034 0.1778 0.004 0.000 0.000 0.034 0.2222 0.004 0.000 0.000 0.034 0.2667 0.004 0.000 0.000 0.034 0.3111 0.004 0.000 0.000 0.034 0.3556 0.004 0.000 0.000 0.034 0.4000 0.004 0.000 0.000 0.034 0.4444 0.004 0.000 0.000 0.034 0.4889 0.004 0.000 0.000 0-034 0.5333 0.004 0.000 0.000 0.034 0.5778 0.004 0.000 0.000 0.034 0.6222 0.004 0.000 0.000 0.034 0.6667 0.004 0.000 0.000 0.034 0.7111 0.004 0.001 0.000 0.034 0.7556 0.004 0.001 0.000 0.034 0.8000 0.004 0.001 0.000 0.034 0.8444 0.004 0.001 0.000 0.034 0.8889 0.004 0.001 0.000 0.034 0.9333 0.004 0.001 0.000 0.034 0.9778 0.004 0.001 0.000 0.034 1-0222 0.004 0.001 0.000 0.034 1.0667 0.004 0.001 0.000 0.034 1.1111 0.004 0.001 0.000 0.034 1.1556 0.004 0.001 0.000 0.034 1.2000 0.004 0.001 0.000 0.034 1.2444 0.004 0.001 0.000 0.034 1.2889 0.004 0.001 0.000 0.034 1.3333 0.004 0.001 0.000 0.034 1.3778 0.004 0.001 0.000 0-034 1.4222 0.004 0.001 0.000 0.034 1.4667 0.004 0.002 0.000 0.034 1.5111 0.004 0.002 0.000 0-034 1.5556 0.004 0.002 0.000 0.034 1.6000 0.004 0.002 0.000 0.034 1.6444 0.004 0.002 0.000 0.034 1.6889 0.004 0.002 0.000 0.034 1.7333 0.004 0.002 0.000 0.034 1.7778 0.004 0.002 0.000 0.034 1.8222 0.004 0.002 0.000 0.034 1.8667 0.004 0.002 0.000 0.034 1.9111 0.004 0.002 0.000 0.034 1.9556 0.004 0.002 0.000 0.034 2.0000 0.004 0.002 0.000 0.034 2.0444 0.004 0.002 0.000 0.034 2.0889 0.004 0.002 0.000 0.034 2.1333 0.004 0.002 0.000 0.034 2.1778 0.004 0.002 0.000 0.034 2.2222 0.004 0.003 0.000 0.034 2.2667 0.004 0.003 0.000 0.034 2.3111 0.004 0.003 0.000 0.034 2.3556 0.004 0.003 0.000 0.034 2.4000 0.004 0.003 0.000 0.034 2.4444 0.004 0.003 0.000 0.034 2.4889 0.004 0.003 0.000 0.034 2.5333 0.004 0.003 0.000 0.034 2.5778 0.004 0.003 0.000 0.034 2.6222 0.004 0.003 0.000 0.034 2.6667 0.004 0.003 0.000 0.034 2.7111 0.004 0.003 0.000 0.034 2.7556 0.004 0.003 0.000 0.034 2.8000 0.004 0.003 0.000 0.034 2.8444 0.004 0.003 0.000 0.034 2.8889 0.004 0.003 0.000 0.034 2.9333 0.004 0.004 0.000 0.034 2.9778 0.004 0.004 0.000 0.034 3.0222 0.004 0.004 0.017 0.034 3.0667 0.004 0.004 0.090 0.034 3.1111 0.004 0.004 0.184 0.034 3.1556 0.004 0.004 0.277 0.034 3.2000 0.004 0.005 0.346 0.034 3.2444 0.004 0.005 0.385 0.034 3.2889 0.004 0.005 0.423 0.034 3.3333 0.004 0.005 0.454 0.034 3.3778 0.004 0.005 0.484 0.034 3.4222 0.004 0.006 0.511 0.034 3.4667 0.004 0.006 0.537 0.034 3.5111 0.004 0.006 0.562 0-034 3.5556 0.004 0.006 0.586 0.034 3.6000 0.004 0.006 0.609 0.034 3.6444 0.004 0.007 0.632 0.034 3-6889 0.004 0.007 0.653 0.034 3-7333 0.004 0.007 0.674 0.034 3.7778 0.004 0.007 0.694 0.034 3.8222 0.004 0.007 0.714 0.034 3.8667 0.004 0.008 0.733 0.034 3.9111, 0.004 0.008 0.751 0.034 3.9556 0.004 0.008 0.769 0.034 4.0000 0.004 0.008 0.787 0.034 ANALYSIS RESULTS Stream Protection Duration Predeveloped Landuse Totals for POC #1 Total Pervious Area:0.09 Total Impervious Area:O Mitigated Landuse Totals for POC #1 Total Pervious Area:O Total Impervious Area:0.09 Flow Frequency Return Periods for Predeveloped. POC #1 Return Period Flow(cfs) 2 year 0.001535 5 year 0.002549 10 year 0.003125 25 year 0.003724 50 year 0.004087 100 year 0.004389 Flow Frequency Return Periods for Mitigated. POC #1 Return Period Flow(cfs) 2 year 0 5 year 0 10 year 0 25 year 0 50 year 0 100 year 0 Stream Protection Duration Annual Peaks for Predeveloped and Mitigated. POC #1 Year Predeveloped Mitigated 1902 0.002 0.000 1903 0.001 0.000 1904 0.002 0.000 1905 0.001 0.000 1906 0.000 0.000 1907 0.002 0.000 1908 0.001 0.000 1909 0.002 0.000 1910 0.003 0.000 1911 0.001 0.000 1912 0.006 0.000 1913 0.002 0.000 1914 0.001 0.000 1915 0.001 0.000 1916 0.001 0.000 1917 0.001 0.000 1918 0.001 0.000 1919 0.001 0.000 1920 0.001 0.000 1921 0.001 0.000 1922 0.002 0.000 1923 0.001 0.000 1924 0.001 0.000 1925 0.001 0.000 1926 0.001 0.000 1927 0.002 0.000 1928 0.001 0.000 1929 0.003 0.000 1930 0.001 0.000 1931 0.001 0.000 1932 0.001 0.000 1933 0.001 0.000 1934 0.004 0.000 1935 0.001 0.000 1936 0.002 0.000 1937 0.002 0.000 1938 0.002 0.000 1939 0.000 0.000 1940 0.001 0.000 1941 0.001 0.000 1942 0.002 0.000 1943 0.001 0.000 1944 0.002 0.000 1945 0.001 0.000 1946 0.001 0.000 1947 0.001 0.000 1948 0.003 0.000 1949 0.003 0.000 1950 0.001 0.000 1951 0.002 0.000 1952 0.005 0.000 1953 0.004 0.000 1954 0.001 0.000 1955 0.001 0.000 1956 0.001 0.000 1957 0.002 0.000 1958 0.004 0.000 1959 0.003 0.000 1960 0.001 0.000 1961 0.003 0.000 1962 0.001 0.000 1963 0.001 0.000 1964 0.001 0.000 1965 0.003 0.000 1966 0.001 0.000 1967 0.001 0.000 1968 0.002 0.000 1969 0.001 0.000 1970 0.002 0.000 1971 0.003 0.000 1972 0.002 0.005 1973 0.002 0.000 1974 0.002 0.000 1975 0.004 0.000 1976 0.002 0.000 1977 0.001 0.000 1978 0.003 0.000 1979 0.001 0.000 1980 0.001 0.000 1981 0.001 0.000 1982 0.001 0.000 1983 0.002 0.000 1984 0.001 0.000 1985 0.001 0.000 1986 0.001 0.000 1987 0.002 0.000 1988 0.002 0.000 1989 0.001 0.000 1990 0.002 0.000 1991 0.001 0.000 1992 0.002 0.000 1993 0.002 0.000 1994 0.003 0.000 1995 0.001 0.000 1996 0.004 0.000 1997 0.002 0.000 1998 0.001 0.000 1999 0.000 0.000 2000 0.001 0.000 2001 0.001 0.000 2002 0.003 0.000 2003 0.002 0.000 2004 0.002 0.000 2005 0.003 0.000 2006 0.001 0.000 2007 0.001 0.000 2008 0.002 0.000 2009 0.001 0.000 2010 0.001 0.000 2011 0.001 0.000 2012 0.001 0.000 2013 0.001 0.000 2014 0-001 0-000 2015 0.003 0.000 2016 0.000 0-000 2017 0.003 0-000 2018 0.005 0.000 2019 0.005 0-000 2020 0.002 0.000 2021 0.002 0.000 2022 0.001 0.000 2023 0.002 0.000 2024 0.006 0.000 2025 0.001 0.000 2026 0.002 0.000 2027 0.001 0.000 2028 0.000 0.000 2029 0.002 0.000 2030 0.003 0.000 2031 0.001 0.000 2032 0.001 0.000 2033 0-001 0.000 2034 0.001 0.000 2035 0.004 0.000 2036 0.002 0.000 2037 0.000 0-000 2038 0.002 0.000 2039 0.000 0.000 2040 0.001 0.000 2041 0.001 0.000 2042 0.004 0.000 2043 0.002 0.000 2044 0.002 0.000 2045 0.001 0.000 2046 0.002 0.000 2047 0.001 0.000 2048 0.001 0.000 2049 0.001 0.000 2050 0.001 0.000 2051 0.001 0.000 2052 0.001 0.000 2053 0.001 0.000 2054 0.003 0.000 2055 0.001 0.000 2056 0.001 0.000 2057 0.001 0.000 2058 0.001 0.000 Stream Protection Duration Ranked Annual Peaks for Predeveloped and Mitigated. POC #1 Rank Predeveloped Mitigated 1 0.0065 0.0053 2 0.0058 0.0000 3 0.0053 0.0000 4 0.0051 0.0000 5 0.0048 0.0000 6 0.0043 0.0000 7 0.0042 0.0000 8 0.0040 0.0000 9 0.0038 0.0000 10 0.0037 0.0000 11 0.0036 0.0000 12 0.0036 0.0000 13 0.0035 0.0000 14 0.0034 0.0000 15 0.0032 0.0000 16 0.0031 0.0000 17 0.0031 0.0000 is 0.0031 0.0000 19 0.0029 0.0000 20 0.0029 0.0000 21 0.0028 0.0000 22 0.0028 0.0000 23 0.0027 0.0000 24 0.0027 0.0000 25 0.0027 0.0000 26 0.0026 0.0000 27 0.0025 0.0000 28 0.0025 0.0000 29 0.0025 0.0000 30 0.0024 0.0000 31 0.0024 0.0000 32 0.0024 0.0000 33 0.0023 0.0000 34 0.0023 0.0000 35 0.0023 0.0000 36 0.0022 0.0000 37 0.0021 0.0000 38 0.0021 0.0000 39 0.0021 0.0000 40 0.0020 0.0000 41 0.0020 0.0000 42 0.0020 0.0000 43 0.0020 0.0000 44 0.0020 0.0000 45 0.0019 0.0000 46 0.0019 0.0000 47 0.0018 0.0000 48 0.0018 0.0000 49 0.0018 0.0000 50 0.0018 0.0000 51 0.0018 0.0000 52 0.0017 0.0000 53 0.0017 0.0000 54 0.0017 0.0000 55 0-0017 0.0000 56 0.0017 0.0000 57 0.0016 0.0000 58 0.0016 0.0000 59 0.0016 0.0000 60 0.0016 0.0000 61 0.0016 0.0000 62 0.0016 0.0000 63 0.0016 0.0000 64 0-0016 0.0000 65 0.0016 0.0000 66 0.0016 0.0000 67 0.0015 0.0000 68 0.0015 0.0000 69 0.0015 0.0000 70 0.0015 0.0000 71 0.0015 0.0000 72 0.0015 0.0000 73 0.0015 0.0000 74 0.0015 0.0000 75 0.0015 0.0000 7C, 0.0014 0.0000 77 0-0014 0.0000 78 0.0014 0.0000 79 0.0014 0.0000 80 0.0014 0.0000 81 0.0014 0.0000 82 0.0014 0.0000 83 0.0014 0.0000 84 0.0014 0.0000 85 0.0014 0.0000 86 0.0014 0.0000 87 0-0014 0.0000 88 0.0013 0.0000 89 0.0013 0.0000 90 0.0013 0.0000 91 0.0013 0.0000 92 0.0013 0.0000 93 0.0013 0.0000 94 0.0013 0.0000 95 0.0013 0.0000 96 0.0013 0.0000 97 0.0012 0.0000 98 0.0012 0.0000 99 0.0012 0.0000 100 0.0012 0.0000 101 0.0012 0.0000 102 0.0012 0.0000 103 0.0012 0.0000 104 0.0011 0.0000 105 0.0011 0.0000 106 0.0011 0.0000 107 0.0011 0.0000 108 0.0011 0.0000 109 0.0011 0.0000 110 0.0011 0.0000 ill 0.0011 0.0000 112 0.0010 0.0000 113 0.0010 0.0000 114 0.0010 0.0000 115 0.0010 0.0000 116 0.0010 0.0000 117 0.0010 0.0000 118 0.0010 0.0000 119 0.0009 0.0000 120 0.0009 0.0000 121 0.0009 0.0000 122 0.0009 0.0000 123 0.0009 0.0000 124 0.0009 0.0000 125 0.0009 0.0000 126 0.0009 0.0000 127 0.0009 0.0000 128 0.0008 0.0000 129 0.0008 0.0000 130 0.0008 0.0000 131 0.0008 0.0000 132 0.0007 0.0000 133 0.0007 0.0000 134 0.0007 0.0000 135 0.0007 0.0000 136 0.0007 0.0000 137 0.0007 0.0000 138 0.0007 0.0000 139 0.0007 0.0000 140 0.0007 0.0000 141 0.0007 0.0000 142 0.0006 0.0000 143 0.0006 0.0000 144 0.0006 0.0000 145 0.0006 0.0000 146 0.0006 0.0000 147 0.0006 0.0000 148 0.0006 0.0000 149 0.0005 0.0000 150 0.0005 0.0000 151 0.0005 0.0000 152 0.0004 0.0000 153 0.0003 0.0000 154 0.0003 0.0000 155 0.0001 0.0000 156 0.0001 0.0000 157 0.0000 0.0000 Stream Protection Duration POC #1 The Facility PASSED The Facility PASSED. Flow(cfs) Predev Mit Percentage Pass/Fail 0.0008 12768 2 0 Pass 0.0008 11578 2 0 Pass 0.0008 10550 2 0 Pass 0.0009 9599 2 0 Pass 0.0009 8797 2 0 Pass 0.0009 8070 2 0 Pass 0.0010 7441 2 0 Pass 0.0010 6850 2 0 Pass 0.0010 6306 2 0 Pass 0.0011 5812 2 0 Pass 0.0011 5337 2 0 Pass 0.0011 4904 2 0 Pass 0.0012 4518 2 0 Pass 0.0012 4173 2 0 Pass 0.0012 3854 2 0 Pass 0.0013 3548 2 0 Pass 0.0013 3275 2 0 Pass 0.0013 3031 2 0 Pass 0.0014 2805 2 0 Pass 0.0014 2615 2 0 Pass 0.0014 2443 2 0 Pass 0.0015 2291 2 0 Pass 0.0015 2118 2 0 Pass 0.0015 1985 2 0 Pass 0�0016 1868 2 0 Pass 0-0016 1763 2 0 Pass 0-0016 1652 2 0 Pass 0.0017 1563 2 0 Pass 0.0017 1478 2 0 Pass 0.0017 1393 2 0 Pass 0.0018 1324 2 0 Pass 0.0018 1246 2 0 Pass 0.0018 1173 2 0 Pass 0.0019 1119 2 0 Pass 0.0019 1054 2 0 Pass 0.0019 1000 2 0 Pass 0.0020 953 0 Pass 0.0020 901 2 0 Pass 0.0020 868 0 0 Pass 0.0021 833 2 0 Pass 0.0021 800 2 0 Pass 0.0021 774 2 0 Pass 0.0022 740 2 0 Pass 0.0022- 717 0 Pass 0.0022 688 2 0 Pass 0.0023 659 2 0 Pass 0.0023 631 2 0 Pass 0.0023 598 2 0 Pass 0.0024 564 2 0 Pass 0.0024 539 e- 0 Pass 0.0024 511 2 0 Pass 0.0025 488 2 0 Pass 0.0025 464 2 0 Pass 0.0025 447 2 0 Pass 0.0026 435 2 0 Pass 0.0026 412 2 0 Pass 0.0026 399 2 0 Pass 0.0027 375 2 0 Pass 0.0027 360 2 0 Pass 0.0027 343 2 0 Pass 0.0028 326 2 0 Pass 0.0028 309 2 0 Pass 0.0028 292 2 0 Pass 0.0029 280 2 0 Pass 0.0029 264 2 0 Pass 0.0029 254 2 0 Pass 0.0030 237 2 0 Pass 0.0030 225 2 0 Pass 0.0030 214 2 0 Pass 0.0031 203 2 0 Pass 0.0031 186 2 1 Pass 0.0031 176 2 1 Pass 0.0032 166 2 1 Pass 0.0032 156 2 1 Pass 0.0032 139 2 1 Pass 0.0033 1218 2 1 Pass 0.0033 120 2 1 Pass 0.0033 112 2 1 Pass 0.0034 99 2 Pass 0.0034 95 2 2 Pass 0.0034 84 2 2 Pass 0.0035 79 2 2 Pass 0.0035 78 2 Pass 0.0036 73 2 Pass 0.0036 66 2 3 Pass 0.0036 61 2 3 Pass 0.0037 53 2 3 Pass 0.0037 47 2 4 Pass 0.0037 43 2 4 Pass 0.0038 39 2 5 Pass 0.0038 36 2 5 Pass 0.0038 34 2 5 Pass 0.0039 31 n 6 Pass 0.0039 29 2 6 Pass 0.0039 27 2 7 Pass 0.0040 27 n 7 Pass 0.0040 25 2 8 Pass 0.0040 21 2 9 Pass 0.0041 21 2 9 Pass 0.0041 19 2 10 Pass Water Quality BMP Flow and Volume for POC #1 On-line facility volume: 0.007 acre-feet On-line facility target flow: 0.0099 cfs. Adjusted for 15 min: 0.0112 cfs. Off-line facility target flow: 0.0056 cfs. Adjusted for 15 min: 0.0064 cfs. LID Report LID Technique Used for Total Volumn Volumn Infiltration Cumulative Percent Water Quality Percent Comment Treatment? Needs Through Volumn Volumn Volumn Water Quality Treatment Facility (ac-ft.) Infiltration Infiltrated Treated (ac-ft) (ac-ft) Credit Gravel Trench Bed I POC N 31.21 N 98.60 Total Volume Infiltrated 31.21 0.00 0.00 98.60 0.00 0% No Treat. Credit Compliance with LID Standard 8 Duration Analysis Result = Passed Per1nd and Imp1nd Changes No change3 have been made - This program and accompanying documentation are provided 'as -is' without warranty of any kind. The entire risk regarding the performance and results of this program is assumed by End User. Clear Creek Solutions Inc. and the governmental licensee or sublicensees disclaim all warranties, either expressed J or implied, including but not limited to implied warranties of program and accompanying documentation. In no event shall Clear Creek Solutions Inc. be liable for any damages whatsoever (including without limitation to damages for loss of business profits, loss of business information, business interruption, and the like) arising out of the use of, or inability to use this program even if Clear Creek Solutions Inc. or their authorized representatives have been advised of the possibility of such damages. Software Copyright 0 by : Clear Creek Solutions, Inc- 2005-2013; All Rights Reserved- Lovell-Sauerland and Associates Final Drainage Report —RI LSA No.5677 Inffitration Trench #2A 0 921 Pine Street JuIv 2018 WWHM2012 PROJECT REPORT Project Name: Infiltration Trench 2A - Lot 2—North Half Roof Site Name: LSA #5677 Site Address: 921 Pine Street city : Edmonds Report Date: 7/16/2018 MGS Regoin : Puget East Data Start : 1901/10/1 Data End : 2058/09/30 DOT Data Number: 03 Version Date: 2017/04/14 Version : 4.2.13 Low Flow Threshold for Poc 1 : 50 Percent of the 2 Year High Flow Threshold for POC 1: 50 year PREDEVELOPED LAND USE Name : Basin 1 Bypass: No GroundWater: No Pervious Land Use acre C, Forest, Mod -0-h Pervious Total 0.031 Impervious Land Use acre Impervious Total 0 Basin Total 0.031 Element Flows To: Surface Interflow MITIGATED LAND USE Name : Basin 1 Bypass: No GroundWater: No Groundwater Pervious Land Use acre Pervious Total 0 Impervious Land Use acre ROOF TOPS FLAT 0-031 Impervious Total 0.031 Basin Total 0.031 Element Flows To: Surface Interflow Groundwater Gravel Trench Bed 1 Gravel Trench Bed 1 Name : Gravel Trench Bed 1 Bottom Length: 37.00 ft. Bottom Width: 4.00 ft. Trench bottom slope 1: 0 To 1 Trench Left side slope 0: 0 To 1 Trench right side slope 2: 0 To 1 Material thickness of first layer: 2 Pour Space of material for first layer: 0.3 Material thickness of second layer: 0 Pour Space of material for second layer: 0 Material thickness of third layer: 0 Pour Space of material for third layer: 0 Infiltration On Infiltration rate: 1.8 Infiltration safety factor: 1 Total Volume Infiltrated (ac-ft.): 11.577 Total Volume Through Riser (ac-ft.): 0 Total Volume Through Facility (ac-ft.): 11.577 Percent Infiltrated: 100 Total Precip Applied to Facility: 0 Total Evap From Facility: 0 Discharge Structure Riser Height: 2 ft. Riser Diameter: 6 in. Element Flows To: Outlet 1 Outlet 2 Gravel Trench Bed Hydraulic Table Stageffeet) Area(ac.) Volume(ac-ft.) Discharge(cfs) Infilt(cfs) 0.0000 0.003 0.000 0.000 0.000 0.0333 0.003 0.000 0.000 0.006 0.0667 0.003 0.000 0.000 0.006 0.1000 0.003 0.000 0.000 0.006 0.1333 0.003 0.000 0.000 0.006 0.1667 0.003 0.000 0.000 0.006 0.2000 0.003 0.000 0.000 0.006 0.2333 0.003 0.000 0.000 0.006 0.2667 0.003 0.000 0.000 0.006 0.3000 0.003 0.000 0.000 0.006 0.3333 0.003 0.000 0.000 0.006 0.3667 0.003 0.000 0.000 0.006 0.4000 0.003 0.000 0.000 0.006 0.4333 0.003 0.000 0.000 0.006 0.4667 0.003 0.000 0.000 0.006 0.5000 0.003 0-000 0.000 0.006 0.5333 0.003 0.000 0.000 0.006 0.5667 0.003 0.000 0.000 0.006 0.6000 0.003 0.000 0.000 0.006 0.6333 0.003 0.000 0.000 0.006 0.6667 0-003 0.000 0.000 0.006 0.7000 0.003 0.000 0.000 0.006 0.7333 0.003 0.000 0.000 0.006 0.7667 0.003 0.000 0.000 0.006 0.8000 0.003 0.000 0.000 0.006 6-j 0.8333 0.003 0.000 0.000 0.006 0.8667 0.003 0.000 0.000 0.006 0.9000 0.003 0.000 0.000 0.006 ,j 0.9333 0.003 0.001 0.000 0.00E 0.9667 0.003 0.001 0.000 0.006 1.0000 0.003 0.001 0.000 0.006 1.0333 0.003 0.001 0.000 0.006 J 1.0667 0.003 0.001 0.000 0.006 1.1000 0.003 0.001 0.000 0.006 1.1333 0.003 0.001 0.000 0.006 1.1667 0.003 0.001 0.000 0.006 1-2000 0-003 0.001 0.000 0.006 1.2333 0.003 0.001 0.000 0.006 1.2667 0.003 0.001 0.000 0.006 1-3000 0-003 0.001 0.000 0.006 1.3333 0.003 0.001 0.000 0.006 1.3667 0.003 0.001 0.000 0.006 1 r 1.4000 0.003 0.001 0.000 0.006 1.4333 0.003 0.001 0.000 0.006 1.4667 0.003 0.001 0.000 0.006 1.5000 0.003 0.001 0.000 0.006 1.5333 0.003 0.001 0.000 0.006 1.5667 0.003 0.001 0.000 0.006 1.6000 0-003 0.001 0.000 0.006 1.6333 0.003 0.001 0.000 0.006 1.6667 0.003 0.001 0.000 0.006 1.7000 0.003 0.001 0.000 0.006 1.7333 0.003 0.001 0.000 0.006 1.7667 0.003 0.001 0.000 0.006 1.8000 0.003 0.001 0.000 0.006 1.8333 0.003 0.001 0.000 0.006 1.8667 0.003 0.001 0.000 0.006 1.9000 0.003 0.001 0.000 0.006 1.9333 0.003 0.002 0.000 0.006 1.9667 0.003 0.002 0.000 0.006 2.0000 0.003 0.002 0.000 0.006 2.0333 0.003 0.002 0.032 0.006 2.0667 0.003 0.002 0.090 0.006 2.1000 0.003 0.002 0.160 0.006 2.1333 0.003 0.002 0.233 0.006 2.1667 0.003 0.002 0.297 0.006 2.2000 0.003 0.002 0.346 0.006 2.2333 0.003 0.002 0.378 0.006 2.2667 0.003 0.003 0.406 0.006 2.3000 0.003 0.003 0.431 0.006 2.3333 0.003 0.003 0.454 0.006 2.3667 0.003 0.003 0.476 0.006 2.4000 0.003 0.003 0.498 0.006 2.4333 0.003 0.003 0.518 0.006 2.4667 0.003 0.003 0.537 0.006 2.5000 0.003 0.003 0.556 0.006 2.5333 0.003 0.003 0.575 0.006 2.5667 0.003 0.004 0.592 0.006 2.6000 0.003 0.004 0.609 0.006 2.6333 0.003 0.004 0.626 0.006 2.6667 0.003 0.004 0.642 0.006 2.7000 0.003 0.004 0.658 0.006 2.7333 0.003 0.004 0.674 0.006 2.7667 0.003 0.004 0.689 0.006 2.8000 0.003 0.004 0.704 0.006 2.8333 0.003 0.004 0.718 0.006 2.8667 0.003 0.005 0.733 0.006 2.9000 0.003 0.005 0.747 0.006 2.9333 0.003 0.005 0.760 0.006 2.9667 0.003 0.005 0.774 0.006 3.0000 0.003 0.005 0.787 0.006 ANALYSIS RESULTS Stream Protection Duration Predeveloped Landuse Totals for POC #1 Total Pervious Area:0.031 Total Impervious Area:O Mitigated Landuse Totals for POC #1 Total Pervious A-rea:O Total Impervious Area:0.031 Flow Frequency Return Periods for Predeveloped. POC #1 Return Period Flow(cfs) 2 year 0.000529 5 year 0.000878 10 year 0.001076 25 year 0.001283 I' - 50 year 0.001408 100 year 0.001512 Flow Frequency Return Periods for mitigated. Poc #1 Return Period Flow(cfs) 2 year 0 5 year 0 10 year 0 25 year 0 50 year 0 100 year 0 Stream Protection Duration Annual Peaks for Predeveloped and Mitigated. POC #1 Year Predeveloped Mitigated 1902 0.001 0.000 1903 0.000 0.000 1904 0.001 0.000 1905 0.000 0.000 1906 0.000 0.000 1907 0.001 0.000 1908 0.001 0.000 1909 0.001 0.000 1910 0.001 0.000 1911 0.000 0.000 1912 0.002 0.000 1913 0.001 0.000 1914 0.000 0.000 1915 0.000 0.000 1916 0.000 0.000 1917 0.000 0.000 1918 0.001 0.000 1919 0.000 0.000 1920 0.000 0.000 1921 0.000 0.000 1922 0.001 0.000 1923 0.000 0.000 1924 0.000 0.000 1925 0.000 0.000 1926 0.000 0.000 1927 0.001 0.000 1928 0.000 0.000 1929 0.001 0.000 1930 0.000 0.000 1931 0.000 0.000 1932 0.000 0.000 1933 0.000 0.000 1934 0.001 0.000 1935 0.000 0.000 1936 0.001 0.000 1937 0.001 0.000 1938 0.001 0.000 1939 0.000 0.000 1940 0.000 0.000 1941 0.000 0.000 1942 0.001 0.000 1943 0.000 0.000 1944 0.001 0.000 1945 0.000 0.000 1946 0.000 0.000 1947 0.000 0.000 1948 0.001 0.000 1949 0.001 0.000 1950 0.000 0.000 1951 0.001 0.000 1952 0.002 0.000 1953 0.001 0.000 1954 0.000 0.000 1955 0.000 0.000 1956 0.000 0.000 1957 0.001 0.000 1958 0.001 0.000 1959 0.001 0.000 1960 0.000 0.000 1961 0.001 0.000 1962 0.000 0.000 1963 0.000 0.000 1964 0.000 0.000 1965 0.001 0.000 1966 0.000 0.000 1967 0.000 0.000 1968 0.001 0-000 1969 0.000 0.000 1970 0.001 0.000 1971 0.001 0.000 1972 0.001 0.002 1973 0.001 0.000 1974 0.001 0.000 1975 0.001 0.000 1976 0.001 0.000 1977 0.000 0.000 1978 0.001 0.000 1979 0.000 0.000 1980 0.000 0.000 1981 0.001 0.000 1982 0.000 0.000 1983 0.001 0.000 1984 0.000 0.000 1985 0.000 0.000 1986 0.000 0.000 1987 0.001 0.000 1988 0.001 0.000 1989 0.000 0.000 1990 0.001 0.000 1991 0.000 0.000 1992 0.001 0.000 1993 0.001 0.000 1994 0.001 0.000 1995 0.000 0.000 1996 0.001 0.000 1997 0"001 0.000 1998 0.001 0.000 1999 0.000 0.000 2000 0.000 0.000 2001 0.000 0.000 2002 0.001 0.000 2003 0.001 0.000 2004 0.001 0.000 2005 0.001 0.000 2006 0.000 0.000 2007 0.000 0.000 2008 0.001 0.000 2009 0.000 0.000 2010 0.000 0.000 2011 0.000 0.000 2012 0.000 0.000 2013 0.000 0.000 2014 0.000 0.000 2015 0.001 0.000 2016 0.000 0.000 2017 0.001 0.000 2018 0.002 0.000 2019 0.002 0.000 2020 0.001 0.000 2021 0.001 0-000 2022 0.000 0.000 2023 0.001 0.000 2024 0.002 0.000 2025 0.000 0.000 2026 0.001 0.000 2027 0.000 0.000 2028 0.000 0.000 2029 0.001 0.000 2030 0.001 0.000 2031 0.000 0.000 2032 0.000 0.000 2033 0.000 0.000 2034 0.000 0.000 2035 0.001 0.000 2036 0.001 0.000 2037 0.000 0.000 2038 0.001 0.000 2039 0.000 0.000 2040 0.000 0.000 2041 0.000 0.000 2042 0.001 0.000 2043 0.001 0.000 2044 0.001 0.000 2045 0.000 0.000 2046 0.001 0.000 2047 0.000 0.000 2048 0.001 0.000 2049 0.000 0.000 2050 0.000 0.000 2051 0.001 0.000 2052 0.000 0.000 2053 0.001 0.000 2054 0.001 0.000 2055 0.000 0.000 2056 0.000 0.000 1 0 2057 0.000 0.000 2058 0.000 0.000 Stream Protection Duration Ranked Annual Peaks for Predeveloped and Mitigated. POC #1 Rank Predeveloped Mitigated 1 0.0022 0.0015 2 0.0020 0.0000 3 0.0018 0.0000 4 0.0018 0.0000 5 0.0017 0.0000 6 0.0015 0.0000 7 0.0015 0.0000 8 0.0014 0.0000 9 0.0013 0.0000 10 0.0013 0.0000 11 0.0013 0.0000 12 0.0012 0.0000 13 0.0012 0.0000 14 0.0012 0.0000 15 0.0011 0.0000 16 0.0011 0.0000 17 0.0011 0.0000 18 0.0011 0.0000 19 0.0010 0.0000 20 0.0010 0.0000 21 0.0010 0.0000 22 0.0010 0.0000 23 0.0009 0.0000 24 0.0009 0.0000 25 0.0009 0.0000 26 0.0009 0.0000 27 0.0009 0.0000 28 0.0009 0.0000 29 0.0009 0.0000 30 0.0008 0.0000 31 0.0008 0.0000 32 0.0008 0.0000 33 0.0008 0.0000 34 0.0008 0.0000 35 0.0008 0.0000 36 0.0008 0.0000 37 0.0007 0.0000 38 0.0007 0.0000 39 0.0007 0.0000 40 0.0007 0.0000 41 0.0007 0.0000 42 0.0007 0.0000 43 0.0007 0.0000 44 0.0007 0.0000 45 0.0007 0.0000 46 0.0006 0.0000 47 0.0006 0.0000 48 0.0006 0.0000 49 0.0006 0.0000 50 0.0006 0.0000 51 0.0006 0.0000 52 0.0006 0.0000 53 0.0006 0.0000 54 0.0006 0.0000 55 0.0006 0.0000 56 0.0006 0.0000 57 0.0006 0.0000 58 0.0006 0.0000 59 0.0006 0.0000 60 0.0006 0.0000 61 0.0006 0.0000 62 0.0006 0.0000 63 0.0006 0.0000 64 0.0005 0.0000 65 0.0005 0.0000 66 0.0005 0.0000 67 0.0005 0.0000 68 0.0005 0.0000 69 0.0005 0.0000 70 0.0005 0.0000 71 0.0005 0.0000 72 0.0005 0.0000 73 0.0005 0.0000 74 0.0005 0.0000 75 0.0005 0.0000 76 0.0005 0.0000 77 0.0005 0.0000 78 0.0005 0.0000 79 0.0005 0.0000 80 0.0005 0.0000 81 0.0005 0.0000 82 0.0005 0.0000 83 0.0005 0.0000 84 0.0005 0.0000 85 0.0005 0.0000 86 0.0005 0.0000 87 0.0005 0.0000 88 0.0005 0.0000 89 0.0005 0.0000 90 0.0005 0.0000 91 0.0005 0.0000 92 0.0005 0.0000 93 0.0004 0.0000 94 0.0004 0.0000 95 0.0004 0.0000 96 0.0004 0.0000 97 0.0004 0.0000 98 0.0004 0.0000 99 0.0004 0.0000 100 0.0004 0.0000 101 0.0004 0.0000 102 0.0004 0.0000 103 0.0004 0.0000 104 0.0004 0.0000 105 0.0004 0.0000 106 0.0004 0.0000 107 0.0004 0.0000 108 0.0004 0.0000 109 0.0004 0.0000 110 0.0004 0.0000 ill 0.0004 0.0000 112 0.0004 0.0000 113 0.0004 0.0000 114 0.0004 0.0000 115 0.0003 0.0000 116 0.0003 0.0000 117 0.0003 0.0000 118 0.0003 0.0000 119 0.0003 0.0000 120 0.0003 0.0000 121 0.0003 0.0000 122 0.0003 0.0000 123 0.0003 0.0000 124 0.0003 0.0000 125 0.0003 0.0000 126 0.0003 0.0000 127 0.0003 0.0000 128 0.0003 0.0000 129 0.0003 0.0000 130 0.0003 0.0000 131 0.0003 0.0000 132 0.0003 0-0000 133 0.0003 0.0000 134 0.0003 0.0000 135 0.0002 0.0000 136 0.0002 0.0000 137 0.0002 0.0000 138 0.0002 0.0000 139 0.0002 0.0000 140 0.0002 0.0000 141 0.0002 0.0000 142 0.0002 0.0000 143 0.0002 0.0000 144 0.0002 0.0000 145 0.0002 0.0000 146 0.0002 0.0000 147 0.0002 0.0000 148 0.0002 0.0000 149 0.0002 0.0000 150 0.0002 0.0000 151 0.0002 0.0000 152 0.0001 0.0000 153 0.0001 0.0000 154 0.0001 0.0000 155 0.0000 0.0000 156 0.0000 0.0000 157 0.0000 0.0000 Stream Protection Duration POC #1 The Facility PASSED The Facility PASSED. IL --j I L Flow(cfs) Predev Mit Percentage Pass/Fail 0.0003 12788 2 0 Pass 0.0003 11569 2 0 Pass 0.0003 10570 2 0 Pass 0-0003 9599 2 0 Pass 0.0003 8814 2 0 Pass 0.0003 8073 2 0 Pass 0.0003 7468 2 0 Pass 0.0003 6857 2 0 Pass 0.0004 6324 2 0 Pass 0.0004 5822 2 0 Pass 0.0004 5322 2 0 Pass 0.0004 4917 2 0 Pass 0.0004 4509 2 0 Pass 0.0004 4193 2 0 Pass 0.0004 3847 2 0 Pass 0.0004 3556 2 0 Pass 0.0004 3274 2 0 Pass 0.0005 3039 2 0 Pass 0.0005 2809 2 0 Pass 0.0005 2625 2 0 Pass 0.0005 2448 2 0 Pass 0.0005 2290 2 0 Pass 0.0005 2121 2 0 Pass 0.0005 1985 2 0 Pass 0.0005 1872 2 0 Pass 0.0006 1762 2 0 Pass 0.0006 1658 2 0 Pass 0.0006 1563 2 0 Pass 0.0006 1484 2 0 Pass 0.0006 1393 2 0 Pass 0.0006 1323 2 0 Pass 0.0006 1248 2 0 Pass 0.0006 1172 2 0 Pass 0.0006 1121 2 0 Pass 0-0007 1053 2 0 Pass 0.0007 1002 2 0 Pass 0.0007 953 2 0 Pass 0.0007 905 2 0 Pass 0.0007 868 2 0 Pass 0.0007 835 2 0 Pass 0.0007 802 2 0 Pass 0.0007 774 2 0 Pass 0.0007 740 2 0 Pass 0.0008 717 2 0 Pass 0.0008 688 2 0 Pass 0.0008 658 2 0 Pass 0.0008 631 2 0 Pass 0.0008 599 2 0 Pass 0.0008 565 2 0 Pass 0.0008 539 2 0 Pass 0.0008 511 2 0 Pass 0.0009 489 2 0 Pass 0.0009 464 2 0 Pass 0.0009 447 2 0 Pass 0.0009 435 2 0 Pass 0.0009 413 2 0 Pass 0.0009 399 2 0 Pass 0.0009 376 2 0 Pass 0.0009 360 2 0 Pass 0.0009 343 2 0 Pass 0.0010 326 2 0 Pass 0.0010 309 2 0 Pass 0.0010 292 2 0 Pass 0.0010 279 2 0 Pass 0.0010 265 2 0 Pass 0.0010 254 2 0 Pass 0.0010 238 2 0 Pass 0.0010 225 2 0 Pass 0.0010 216 2 0 Pass 0.0011 203 2 0 Pass 0.0011 185 2 1 Pass 0.0011 176 2 1 Pass 0.0011 166 2 1 Pass 0.0011 156 2 1 Pass 0.0011 139 2 1 Pass 0.0011 128 2 1 Pass 0.0011 120 2 1 Pass 0.0012 112 2 1 Pass 0.0012 99 2 2 Pass 0.0012 95 2 2 Pass 0.0012 84 2 2 Pass 0.0012 79 2 2 Pass 0.0012 78 2 2 Pass 0.0012 73 2 2 Pass 0.0012 66 2 3 Pass 0.0012 61 2 3 Pass 0.0013 54 2 3 Pass 0.0013 47 2 4 Pass 0.0013 44 2 4 Pass 0.0013 39 2 5 Pass 0.0013 36 2 5 Pass 0.0013 34 2 5 Pass 0.0013 31 2 6 Pass 0.0013 29 2 6 Pass 0.0014 27 2 7 Pass 0.0014 27 2 7 Pass 0.0014 25 2 8 Pass 0.0014 21 2 9 Pass 0.0014 21 2 9 Pass 0.0014 19 2 10 Pass Water Quality BMP Flow and Volume for POC #1 On-line facility volume: 0.0063 acre-feet On-line facility target flow: 0.0088 cfs. Adjusted for 15 min: 0.0099 cfs. Off-line facility target flow: 0.005 cfs. Adjusted for 15 min: 0.0056 cfs. LID Report t _j LID Technique Used for Total Volumn Volumn Infiltration Cumulative Percent Water Quality Percent Comment Treatment? Needs Through Volumn Volumn Volumn Water Quality Treatment Facility (ac-ft.) Infiltration Infiltrated Treated (ac-ft) (ac-ft) Credit Gravel Trench Bed I POC N 10.72 N 98.32 Total Volume Infiltrated 10.72 0.00 0.00 98.32 0.00 0% No Treat. Credit Compliance with LID Standard 8 Duration Analysis Result = Passed Per1nd and Imp1nd Changes kj No changes have been made. This program and accompanying documentation are provided 'as -is' without warranty of any kind. The k_J entire risk regarding the performance and results of this program is assumed by End User. Clear Creek Solutions Inc- and the governmental licensee or sublicensees disclaim all warranties, either expressed or implied, including but not limited to implied warranties of program and accompanying documentation. In no event shall Clear Creek Solutions Inc. be liable for any damages whatsoever (including without limitation to damages for loss of business profits, loss of business information, business interruption, and the like) arising out of the use of, or inability to use this program even if Clear Creek Solutions Inc. or their authorized representatives have been advised of the possibility of such damages. Software Copyright 0 by : Clear Creek Solutions, Inc. 2005-2018; All Rights Reserved. IL Lovell-Satterland and Associates Final Drainage Report—Rl LSA No. 5677 Inffltration Trench #2B L.WR 921 Pine Street July 2018 WWHM2012 PROJECT REPORT Project Name: Infiltration Trench 2B - Lot 2-S Half Roof+Misc Site Name: LSA #5677 Site Address: 921 Pine Street city : Edmonds Report Date: 7/16/2018 MGS Regoin : Puget East Data Start : 1901/10/1 Data End : 2058/09/30 DOT Data Number: 03 Version Date: 2017/04/14 Version : 4.2.13 Low Flow Threshold for Poc 1 : 50 Percent of the 2 Year High Flow Threshold for POC 1: 50 year PREDEVELOPED LAM USE Nam.- : Basin I Bypass: No GroundWater: No Pervious Land Use acre C, Forest, Mod .048 Pervious Total 0.048 Impervious Land Use acre Impervious Total 0 Basin Total 0.048 Element Flows To: Surface Interflow MITIGATED LAND USE Name : Basin 1 Bypass: No GroundWater: No Groundwater Pervious Land Use acre Pervious Total 0 Impervious Land Use acre ROOF TOPS FLAT 0.026 DRIVEWAYS MOD 0.022 Impervious Total 0.048 Basin Total 0.048 Element Flows To: surface Interflow Groundwater Gravel Trench Bed 1 Gravel Trench Bed 1 Name : Gravel Trench Bed I Bottom Length: 32.00 ft. Bottom Width: 8.00 ft. Trench bottom slope 1: 0 To 1 Trench Left side slope 0: 0 To 1 Trench right side slope 2: 0 To 1 Material thickness of first layer: 2 Pour Space of material for first layer: 0.3 Material thickness of second layer: 0 Pour Space of material for second layer: 0 Material thickness of third layer: 0 Pour Space of material for third layer: 0 Infiltration on Infiltration rate: 1.8 Infiltration safety factor: 1 Total Volume Infiltrated (ac-ft.): 18.211 Total Volume Through Riser (ac-ft.): 0 Total Volume Through Facility (ac-ft.): 18.211 Percent Infiltrated: 100 Total Precip Applied to Facility: 0 Total Evap From Facility: 0 Discharge Structure Riser Height: 2 ft. Riser Diameter: 6 in. Element Flows To: outlet 1 Outlet 2 Gravel Trench Bed Hydraulic Table S"gleffeet) Area(ac.) Volume(ac-ft.) Discharge(cfs) Infilt(cfs) 0.0000 0.005 0.000 0.000 0.000 0.0333 0.005 0.000 0.000 0.010 0.0667 0.005 0.000 0.000 0.010 0.1000 0.005 0.000 0.000 0.010 0.1333 0.005 0.000 0.000 0.010 0.1667 0.005 0.000 0.000 0.010 0.2000 0.005 0.000 0.000 0.010 0.2333 0.005 0.000 0.000 0.010 0.2667 0.005 0.000 0.000 0.010 0.3000 0.005 0.000 0.000 0.010 0.3333 0.005 0.000 0.000 0.010 0.3667 0.005 0.000 0-000 0.010 0.4000 0.005 0.000 0.000 0.010 0-4333 0.005 0.000 0.000 0.010 0.4667 0.005 0.000 0.000 0.010 0.5000 0.005 0.000 0.000 0.010 0.5333 0.005 0.000 0.000 0.010 0.5667 0.005 0.001 0.000 0.010 0.6000 0.005 0.001 0.000 0.010 0.6333 0-005 0.001 0.000 0.010 0.6667 0.005 0-001 0.000 0.010 0.7000 0.005 0.001 0.000 0.010 0.7333 0.005 0.001 0.000 0.010 0.7667 0.005 0-001 0.000 0.010 0.8000 0.005 0.001 0.000 0.010 0.8333 0.005 0.001 0.000 0.010 0.8667 0.005 0.001 0.000 0.010 0.9000 0.005 0.001 0.000 0.010 0.9333 0.005 0.001 0.000 0.010 0.9667 0.005 0.001 0.000 0.010 1.0000 0.005 0.001 0.000 0.010 1-0333 0-005 0.001 0.000 0.010 1.0667 0.005 0.001 0.000 0.010 rl 1-1000 0.005 0.001 0.000 0.010 i 1-1333 0.005 0.002 0.000 0.010 1.1667 0-005 0.002 0.000 0.010 1.2000 0.005 0.002 0.000 0.010 1.2333 0.005 0.002 0.000 0.010 1.2667 0.005 0.002 0.000 0-010 1.3000 0.005 0.002 0.000 0.010 1.3333 0-005 0.002 0.000 0.010 1-3667 0.005 0.002 0.000 0.010 1.4000 0.005 0.002 0.000 0.010 1.4333 0.005 0.002 0.000 0.010 1.4667 0.005 0.002 0.000 0.010 1.5000 0.005 0.002 0.000 0.010 1.5333 0.005 0.002 0.000 0.010 1.5667 0.005 0.002 0.000 0.010 1.6000 0.005 0.002 0.000 0.010 1.6333 0.005 0.002 0.000 0.010 1.6667 0.005 0.002 0.000 0.010 1.7000 0.005 0.003 0.000 0.010 1.7333 0.005 0.003 0.000 0.010 1.7667 0.005 0.003 0.000 0.010 1.8000 0.005 0.003 0.000 0.010 1.8333 0.005 0.003 0.000 0.010 1.8667 O.Oos 0.003 0.000 0.010 1.9000 0.005 0.003 0.000 0.010 1.9333 0.005 0.003 0.000 0.010 1.9667 0.005 0.003 0.000 0.010 2.0000 0.005 0.003 0.000 0.010 2.0333 0.003 0.032 0.010 2.0667 0.005 0.004 0.090 0.010 2.1000 0.005 0.004 0.160 0.010 2-1333 0.005 0.004 0.233 0.010 2.1667 0.005 0.004 0.297 0.010 2.2000 0.005 0.004 0.346 0.010 2.2333 0.005 0.005 0.378 0.010 2.2667 0.005 0.005 0.406 0.010 2.3000 0.005 0.005 0.431 0.010 2.3333 0.005 0.005 0.454 0.010 2.3667 0.005 0.005 0.476 0.010 2.4000 0.005 0.006 0.498 0.010 2.4333 0.005 0.006 0.518 0.010 2.4667 0.005 0.006 0.537 0.010 2.5000 0.005 0.006 0.556 0.010 2.5333 0.005 0.006 0.575 0.010 2.5667 0.005 0.007 0.592 0.010 2.6000 0.005 0.007 0.609 0.010 2.6333 0.005 0.007 0.626 0.010 2.6667 0.005 0.007 0.642 0.010 2.7000 0.005 0.007 0.658 0.010 2.7333 0.005 0.008 0.674 0.010 2.7667 0.005 0.008 0.689 0.010 2.8000 0.005 0.008 0.704 0.010 2.8333 0.005 0.008 0.718 0.010 2.8667 0.005 0.008 0.733 0.010 2.9000 0.005 0.009 0.747 0.010 2-9333 0.005 0.009 0.760 0.010 2.9667 0.005 0.009 0.774 0.010 3.0000 0.005 0.009 0.787 0.010 ANALYSIS RESULTS Stream Protection Duration Predeveloped Landuse Totals for POC #1 Total Pervious Area:0.048 Total Impervious Area:O Mitigated Landuse Totals for POC #1 Total Pervious Area:O Total Impervious Area:0.048 Flow Frequency Return Periods for Predeveloped. POC #1 Return Period Flow(cfs) 2 year 0.000819 5 year 0.00136 10 year 0.001666 j 25 year 0.001986 50 year 0.00218 100 year 0.002341 Flow Frequency Return Periods for Mitigated. POC #1 Return Period Flow(cfs) 2 year 0 5 year 0 10 year 0 25 year 0 50 year 0 100 year 0 Stream Protection Duration Annual Peaks for Predeveloped and Mitigated. POC #1 Year Predeveloped Mitigated 1902 0.001 0.000 1903 0.000 0.000 1904 0.001 0,000 1905 0.000 0.000 1906 0.000 0.000 1907 0.001 0.000 1908 0.001 0.000 1909 0.001 0.000 1910 0.001 0.000 1911 0-001 0.000 1912 0.003 0.000 1913 0.001 0.000 1914 0.000 0.000 1915 0.000 0.000 1916 0.001 0.000 1917 0.000 0.000 1918 0.001 0.000 1919 0.001 0.000 1920 0.001 0.000 1921 0.001 0.000 1922 0.001 0.000 1923 0.001 0.000 1924 0.000 0.000 1925 0.000 0.000 1926 0.001 0.000 1927 0.001 0.000 1928 0.001 0.000 1929 0.001 0.000 1930 0.001 0.000 1931 0.001 0,000 1932 0.001 0.000 1933 0.001 0.000 1934 0.002 0.000 1935 0.001 0.000 1936 0.001 0.000 1937 0.001 0.000 1938 0.001 0.000 1939 0.000 0.000 1940 0.001 0.000 1941 0.001 0.000 1942 0.001 0.000 1943 0.000 0.000 1944 0.001 0.000 1945 0.001 0.000 1946 0.001 0.000 1947 0.000 0.000 1948 0.002 0.000 1949 0.001 0.000 1950 0.001 0.000 1951 0.001 0.000 1952 0.003 0.000 1953 0.002 0.000 1954 0.001 0.000 1955 0.001 0.000 1956 0.000 0.000 1957 0.001 0.000 1958 0.002 0-000 1959 0.001 0.000 1960 0.000 0.000 1961 0.001 0.000 1962 0-001 0.000 1963 0.000 0.000 1964 0.001 0.000 1965 0.002 0.000 1966 0.000 0.000 1967 0.001 0.000 1968 0.001 0.000 1969 0.001 0.000 1970 0.001 0.000 1971 0.002 0.000 1972 0.001 0.000 1973 0.001 0.000 1974 0.001 0.000 1975 0.002 0.000 1976 0-001 0.000 1977 0.000 0.000 1973 0.002 0.000 1979 0.000 0.000 1980 0.001 0.000 1981 0.001 0.000 1982 0.001 0.000 1983 0.001 0.000 1984 0.000 0.000 1985 0.001 0.000 1986 0.001 0.000 1987 0.001 0.000 1988 0.001 0.000 1989 0.001 0.000 1990 0.001 0.000 1991 0.001 0.000 1992 0.001 0.000 1993 0.001 0.000 1994 0.002 0.000 1995 0.000 0.000 1996 0.002 0.000 1997 0.001 0.000 1998 0.001 0.000 1999 0.000 0.000 2000 0.001 0.000 2001 0.000 0.000 2002 0.002 0.000 2003 0.001 0.000 2004 0.001 0.000 2005 0.001 0.000 2006 0.001 0.000 2007 0.001 0.000 2008 0.001 0.000 2009 0.000 0.000 2010 0.000 0.000 2011 0.001 0.000 2012 0.001 0.000 2013 0.001 0.000 2014 0.000 0.000 2015 0.002 0.000 2016 0.000 0.000 2017 0.001 0.000 2018 0.003 0.000 2019 0.003 0.000 2020 0.001 0-000 2021 0.001 0.000 2022 0.000 0.000 2023 0.001 0.000 2024 0.003 0.000 2025 0.001 0.000 2026 0.001 0.000 2027 0.001 0.000 2028 0.000 0.000 2029 0.001 0.000 2030 0.002 0.000 2031 0.000 0.000 2032 0.000 0.000 2033 0.000 0.000 2034 0.000 0.000 2035 0.002 0.000 2036 0.001 0.000 2037 0.000 0.000 2038 0.001 0.000 2039 0.000 0.000 2040 0.000 0.000 2041 0.001 0.000 2042 0.002 0.000 2043 0.001 0.000 2044 0.001 0.000 2045 0.001 0.000 2046 0.001 0.000 2047 0.001 0.000 2048 0.001 0.000 2049 0.001 0.000 2050 0.000 0.000 2051 0.001 0.000 2052 0.000 0.000 2053 0.001 0.000 2054 0.002 0.000 2055 0.000 0.000 2056 0.000 0.000 2057 0.001 0.000 2058 0.001 0.000 Stream Protection Duration Ranked Annual Peaks for Predeveloped and Mitigated. POC #1 Rank Predeveloped Mitigated 1 0.0035 0.0000 2 0.0031 0.0000 3 0.0028 0.0000 4 0.0027 0.0000 5 0.0026 0.0000 6 0.0023 0.0000 7 0.0023 0.0000 8 0.0021 0.0000 9 0.0020 0.0000 10 0.0020 0.0000 11 0.0019 0.0000 12 0.0019 0.0000 13 0.0019 0.0000 14 0.0018 0.0000 15 0.0017 0.0000 16 0.0016 0.0000 17 0.0016 0.0000 18 0.0016 0.0000 19 0.0016 0.0000 20 0.0016 0.0000 21 0.0015 0.0000 22 0.0015 0.0000 23 0.0014 0.0000 24 0.0014 0.0000 25 0.0014 0.0000 26 0.0014 0.0000 27 0.0014 0.0000 28 0.0014 0,0000 29 0.0013 0.0000 30 0.0013 0.0000 31 0.0013 0.0000 32 0.0013 0.0000 33 0.0012 0.0000 34 0.0012 0.0000 35 0.0012 0.0000 36 0.0012 0.0000 37 0.0011 0.0000 38 0.0011 0.0000 39 0.0011 0.0000 40 0.0011 0.0000 41 0.0011 0.0000 42 0.0011 0.0000 43 0.0010 0.0000 44 0.0010 0.0000 45 0.0010 0.0000 46 0.0010 0.0000 47 0.0010 0.0000 48 0.0010 0.0000 49 0.0010 0.0000 50 0.0009 0.0000 51 0.0009 0.0000 52 0.0009 0.0000 53 0.0009 0.0000 54 0.0009 0.0000 55 0.0009 0.0000 56 0.0009 0.0000 57 0.0009 0.0000 58 0.0009 0.0000 59 0.0009 0.0000 60 0.0009 0.0000 61 0.0009 0.0000 62 0.0009 0.0000 63 0.0009 0.0000 64 0.0008 0.0000 65 0.0008 0.0000 66 0.0008 0.0000 67 0.0008 0.0000 68 0.0008 0-0000 69 0.0008 0.0000 70 0.0008 0.0000 71 0.0008 0.0000 72 0.0008 0.0000 73 0.0008 0.0000 74 0.0008 0.0000 75 0.0008 0-0000 76 0.0008 0.0000 77 0.0008 0.0000 78 0.0008 0-0000 79 0.0008 0.0000 80 0.0008 0.0000 81 0.0007 0.0000 82 0.0007 0.0000 83 0.0007 0.0000 84 0.0007 0.0000 85 0.0007 0.0000 86 0.0007 0-0000 87 0.0007 0.0000 88 0.0007 0.0000 89 0.0007 0.0000 90 0.0007 0.0000 91 0.0007 0.0000 92 0.0007 0.0000 93 0.0007 0.0000 94 0.0007 0.0000 95 0.0007 0-0000 96 0.0007 0.0000 97 0.0007 0.0000 98 0.0006 0.0000 99 0.0006 0.0000 100 0.0006 0.0000 101 0.0006 0.0000 102 0.0006 0.0000 103 0.0006 0.0000 104 0.0006 0.0000 105 0.0006 0.0000 106 0.0006 0.0000 107 0.0006 0.0000 108 0.0006 0.0000 109 0.0006 0.0000 110 0.0006 0.0000 ill 0.0006 0.0000 112 0.0006 0.0000 113 0.0005 0.0000 114 0.0005 0.0000 115 0.0005 0.0000 116 0.0005 0.0000 117 0.0005 0.0000 118 0.0005 0.0000 119 0.0005 0.0000 120 0.0005 0.0000 121 0.0005 0.0000 122 0.0005 0.0000 123 0.0005 0.0000 124 0.0005 0.0000 125 0.0005 0.0000 126 0.0005 0.0000 127 0.0005 0.0000 128 0.0004 0.0000 129 0.0004 0.0000 130 0.0004 0.0000 131 0.0004 0.0000 132 0.0004 0.0000 133 0.0004 0.0000 134 0.0004 0.0000 135 0.0004 0.0000 136 0.0004 0.0000 137 0.0004 0.0000 138 0.0004 0.0000 139 0.0004 0.0000 140 0.0004 0.0000 141 0.0004 0.0000 142 0.0003 0.0000 143 0.0003 0.0000 144 0.0003 0.0000 145 0.0003 0.0000 146 0.0003 0.0000 147 0.0003 0.0000 148 0.0003 0.0000 149 0.0003 0.0000 150 0.0003 0.0000 151 0.0003 0.0000 152 0.0002 0.0000 153 0.0002 0.0000 154 0.0002 0.0000 155 0.0001 0.0000 156 0.0000 0.0000 157 0.0000 0.0000 Stream Protection Duration POC #1 The Facility PASSED The Facility PASSED. Flow(cfs) Predev Mit Percentage Pass/Fail 0.0004 12773 0 0 Pass 0.0004 11591 0 0 Pass 0.0004 10532 0 0 Pass 0.0005 9598 0 0 Pass 0.0005 8776 0 0 Pass 0.0005 8086 0 0 Pass 0.0005 745S 0 0 Pass 0.0005 6863 0 0 Pass 0.0006 6306 0 0 Pass 0.0006 5817 0 0 Pass 0.0006 5332 0 0 Pass 0.0006 4901 0 0 Pass 0.0006 4509 0 0 Pass 0.0006 4193 0 0 Pass 0.0007 3855 0 0 Pass 0.0007 3553 0 0 Pass 0.0007 3275 0 0 Pass 0.0007 3032 0 0 Pass 0.0007 2-809 0 0 Pass 0.0007 2615 0 0 Pass 0.0008 2443 0 0 Pass 0.0008 2290 0 0 Pass 0.0008 212-2 0 0 Pass 0.0008 1989 0 0 Pass 0.0008 1870 0 0 Pass 0.0009 1763 0 0 Pass 0.0009 1654 0 0 Pass 0.0009 1562- 0 0 Pass 0.0009 1.478 0 0 Pass 0.0009 1393 0 0 Pass 0.0009 1323 0 0 Pass 0.0010 1248 0 0 Pass 0.0010 1175 0 0 Pass 0.0010 1120 0 0 Pass 0.0010 1054 0 0 Pass 0.0010 1000 0 0 Pass 0.0011 953 0 0 Pass 0.0011 901 0 0 Pass 0.0011 867 0 0 Pass 0.0011 835 0 0 Pass 0.0011 802 0 0 Pass 0.0011 774 0 0 Pass 0.0012 740 0 0 Pass 0.0012 717 0 0 Pass 0.0012 688 0 0 Pass 0.0012 658 0 0 Pass 0.0012 630 0 0 Pass 0,0013 597 0 0 Pass 0.0013 565 0 0 Pass 0.0013 539 0 0 Pass 0.0013 512 0 0 Pass 0.0013 488 0 0 Pass 0.0013 465 0 0 Pass 0.0014 447 0 0 Pass 0.0014 434 0 0 Pass 0.0014 412 0 0 Pass 0.0014 401 0 0 Pass 0.0014 375 0 0 Pass 0.0014 360 0 0 Pass 0.0015 343 0 0 Pass 0.0015 326 0 0 Pass 0.0015 309 0 0 Pass 0.0015 292 0 0 Pass 0.0015 279 0 0 Pass 0.0016 263 0 0 Pass 0.0016 254 0 0 Pass 0.0016 237 0 0 Pass 0.0016 225 0 0 Pass 0.0016 214 0 0 Pass 0.0016 203 0 0 Pass 0.0017 185 0 0 Pass 0-0017 176 0 0 Pass 0.0017 166 0 0 Pass 0_001� 155 0 0 Pass 0.0017 140 0 0 Pass 0.0018 128 0 0 Pass 0.0018 120 0 0 Pass 0.0018 112 0 0 Pass 0.0018 99 0 0 Pass 0-0018 95 0 0 Pass 0-0018 84 0 0 Pass 0-0019 79 0 0 Pass 0.0019 78 0 0 Pass 0.0019 73 0 0 Pass 0.0019 66 0 0 Pass 0,0019 61 0 0 Pass 0.0019 53 0 0 Pass 0-0020 47 0 0 Pass 0.0020 43 0 0 Pass 0.0020 39 0 0 Pass 0.0020 36 0 0 Pass 0.001-0 34 0 0 Pass 0.0021 31 0 0 Pass 0.0021 29 0 0 Pass 0.0021 27 0 0 Pass 0.0021 27 0 0 Pass 0.0021 25 0 0 Pass 0.0021 21 0 0 Pass 0.0022 0 0 Pass 0.0022 19 0 0 Pass Water Quality BMP Flow and Volume for POC #1 On-line facility volume: 0.0063 acre-feet On-line facility target flow: 0.0088 cfs. Adjusted for 15 min: 0.0099 cfs. Off-line facility target flow: 0.005 cfs. Adjusted for 15 min: 0.0056 cfs. LID Report LID Technique Used for Total Volumn Volumn Infiltration Cumulative Percent Water Quality Percent Comment Treatment? Needs Through Volumn Volumn Volumn Water Quality Treatment Facility (ac-ft.) Infiltration Infiltrated Treated (ac-ft) (ac-ft) Credit Gravel Trench Bed I POC N 16.73 N 99.03 Total Volume Infiltrated 16.73 0.00 0.00 99.03 0.00 0% No Treat. Credit Compliance with LID Standard 8 Duration Analysis Result = Passed -ej Per1nd and Imp1nd Changes No changes have been made - This program and accompanying documentation are provided 'as -is' without warranty of any kind. The entire risk regarding the performance and results of this program is assumed by End User. Clear Creek Solutions Inc. and the governmental licensee or sublicensees disclaim all warranties, either expressed or implied, including but not limited to implied warranties of program and accompanying documentation. In no event shall Clear Creek Solutions Inc. be liable for any damages whatsoev'er (including without limitation to damages for loss of business profits, loss of business information, business interruption, and the like) arising out of the use of, or inability to use this program even if Clear Creek Solutions Inc. or their authorized representatives have been advised of the possibility of such damages- Software Copyright 0 by : Clear Creek Solutions, Inc. 2005-2018; All Rights Reserved- t DryweH OA Lovell-Sauerland and Associates 921 Pine Street Final Drainage Report—R] July 2018 LSA No.5677 L.MR WWHM2012 PROJECT REPORT Project Name: Drywell #3A - Lot 3—Roof Only Site Name: LSA #5677 Site Address: 921 Pine Street city : Edmonds Report Date: 1/14/2018 MGS Regoin Puget East Data Start 1901/10/1 Data End : 2058/09/30 DOT Data Number: 03 Version Date: 2017/04/14 Version : 4.2.13 Low Flow Threshold for POC 1 : 50 Percent of the 2 Year High Flow Threshold for POC 1: 50 year PREDEVELOPED LAND USE Name : Basin 1 Bypass: No GroundMater: No Pervious Land Use acre C, Forest, Mod .07 Pervious Total 0.07 Impervious Land Use acre Impervious Total 0 Basin Total 0.07 Element Flows To: Surface Interflow MITIGATED LAND USE Name : Basin 1 Bypass: No GroundWater: No 3-� Groundwater .1* Pervious Land Use acre Pervious Total 0 Impervious Land Use acre ROOF TOPS FLAT 0.07 Impervious Total 0.07 Basin Total 0.07 Element Flows To: Surface Interflow Groundwater Gravel Trench Bed 1 Gravel Trench Bed 1 Name Gravel Trench Bed I Bottom Length: 16.00 ft. Bottom Width: 14.00 ft. Trench bottom slope 1: 0 To 1 Trench Left side slope 0: 0 To 1 Trench right side slope 2: 0 To 1 Material thickness of first layer: 2.5 Pour Space of material for first layer: 0.3 Material thickness of second layer: 0 Pour Space of material for second layer: 0 Material thickness of third layer: 0 Pour Space of material for third layer: 0 Infiltration On Infiltration rate: 3.8 Infiltration safety factor: 1 Total Volume Infiltrated (ac-ft.): 2-6.278 Total Volume Through Riser (ac-ft.): 0.001 Total Volume Through Facility (ac-ft.): 26.279 Percent Infiltrated: 100 Total Precip Applied to Facility: 0 Total Evap From Facility: 0 Discharge Structure Riser Height: 2.5 ft. Riser Diameter: 6 in. Element Flows To: outlet 1 outlet 2 Gravel Trench Bed Hydraulic Table Stageffeet) Araa(ac.) Volume(ac-ft.) Discharge(afs) Infilt(cfs) 0.0000 0.005 0.000 0.000 0.000 0.0389 0.005 0.000 0.000 0.019 0.0778 0.005 0.000 0.000 0.019 0.1167 0.005 0.000 0.000 0.019 0.1556 0.005 0.000 0.000 0.019 0.1944 0.005 0.000 0.000 0.019 0.2333 0.005 0.000 0.000 0.019 0.2722 0.005 0.000 0.000 0.019 0.3111 0.005 0.000 0.000 0.019 0.3500 0.005 0.000 0.000 0.019 0.3889 0.005 0.000 0.000 0.019 0.4278 0.005 0.000 0.000 0.019 0.4667 0.005 0.000 0.000 0.019 0.5056 0.005 0.000 0.000 0.019 0.5444 0.005 0.000 0.000 0.019 0.5833 0.005 0.000 0.000 0.019 0.6222 0.005 0.001 0.000 0.019 0.6611 0.005 0.001 0.000 0.019 0.7000 0.005 0.001 0.000 0.019 0.7389 0.005 0.001 0.000 0.019 0.7778 0.005 0.001 0.000 0-019 0.8167 0.005 0.001 0.000 0.019 0.8556 0.005 0.001 0.000 0.019 0.8944 0.005 0.001 0.000 0.019 0.9333 0.005 0.001 0.000 0.019 0-9722 0.005 0.001 0.000 0.019 1-0111 0.005 0.001 0.000 0.019 1.0500 0.005 0.001 0.000 0.019 1.0889 0.005 0.001 0-000 0.019 1.1278 0.005 0.001 0.000 0.019 1.1667 0.005 0.001 0.000 0.019 1.2056 0.005 0.001 0.000 0.019 1.2444 0.005 0.001 0.000 0.019 1.2833 0.005 0.002 0.000 0.019 1.3222 0.005 0.002 0.000 0.019 1.3611 0.005 0.002 0.000 0.019 1-4000 0.005 0.002 0.000 0-019 1.4389 0.005 0.002 0.000 0.019 1.4778 0.005 0.002 0.000 0.019 1.5167 0.005 0.002 0.000 0.019 1.5556 0.005 0.002 0.000 0.019 1.5944 0.005 0.002 0.000 0.019 1-6333 0.005 0.002 0.000 0.019 1.6722 0.005 0.002 0.000 0.019 1.7111 0.005 0.002 0.000 0.019 1.7500 0.005 0.002 0.000 0.019 1.7889 0.005 0.002 0.000 0.019 1.8278 0.005 0.002 0.000 0.019 1.8667 0.005 0.002 0.000 0.019 1.9056 0.005 0.002 0.000 0.019 1.9444 0.005 0.003 0.000 0.019 1.9833 0.005 0.003 0.000 0.019 2.0222 0.005 0.003 0.000 0.019 2.0611 0.005 0.003 0.000 0.019 2.1000 0.005 0.003 0.000 0.019 2.1389 0.005 0.003 0.000 0.019 2.1778 0.005 0.003 0.000 0.019 2.2167 0.005 0.003 0.000 0.019 2.2556 0.005 0.003 0.000 0.019 2.2944 0.005 0.003 0.000 0.019 2.3333 0.005 0.003 0.000 0.019 2-3722 0.005 0.003 0.000 0.019 2.4111 0.005 0.003 0.000 0.019 2.4500 0.005 0.003 0.000 0.019 2.4889 0.005 0.003 0.000 0.019 2.5278 0.005 0.004 0.024 0.019 2.5667 0.005 0.004 0.090 0.019 2.6056 0.005 0.004 0.172 0.019 2.6444 0.005 0.004 0.255 0.019 2.6833 0.005 0.004 0.324 0.019 2.7222 0.005 0.005 0.369 0.019 2.7611 0.005 0.005 0.402 0.019 2.8000 0.005 0.005 0.431 0.019 2.8389 0.005 0.005 0.458 0.019 2.8778 0.005 0.005 0.484 0.019 2.9167 0.005 0.006 0.508 0.019 2.9556 0.005 0.006 0.531 0.019 2.9944 0.005 0.006 0.553 0.019 3.0333 0.005 0.006 0.575 0.019 3.0722 0.005 0.006 0.595 0.019 3.1111 0.005 0.007 0.615 0.019 3.1500 0.005 0.007 0.634 0.019 3.1889 0.005 0.007 0.653 0.019 3.2278 0.005 0.007 0.671 0.019 3-2667 0.005 0.007 0.689 0.019 3-3056 0.005 0.008 0.706 0.019 3.3444 0.005 0.008 0.723 0.019 3.3833 0.005 0.008 0.740 0.019 3.4222 0.005 0.008 0.756 0.019 3.4611 0.005 0.008 0.771 0.019 3.5000 0.005 0.009 0.787 0.019 ANALYSIS RESULTS Stream Protection Duration Predeveloped Landuse Totals for POC #1 Total Pervious Area:0.07 Total Impervious Area:O Mitigated Landuse Totals for POC #1 Total Pervious Area:O Total Impervious Area:0.07 Flow Frequency Return Periods for Predeveloped. POC #1 Return Period Flow(cfs) 2 year 0.001194 5 year 0.001983 10 year 0.00243 25 year 0.002897 J-1 50 year 0.003179 100 year 0.003413 Flow Frequency Return Periods for Mitigated. POC #1 Return Period Flow(cfs) 2 year 0 5 year 0 10 year 0 25 year 0 50 year 0 100 year 0 Stream Protection Duration Annual Peaks for Predeveloped and Mitigated. POC #1 Year Predeveloped Mitigated 1902 0.002 0.000 1903 0.001 0.000 1904 0.001 0.000 1905 0.001 0.000 1906 0.000 0.000 1907 0.002 0.000 1908 0-001 0.000 1909 0.001 0.000 1910 0.002 0.000 1911 0.001 0.000 1912 0.004 0.000 1913 0.002 0.000 1914 0-000 0.000 1915 0.001 0.000 1916 0.001 0.000 1917 0.000 0.000 1918 0.001 0-000 1919 0.001 0.000 1920 0.001 0.000 1921 0.001 0.000 1922 0.001 0.000 1923 0.001 0.000 1924 0.001 0.000 1925 0.001 0.000 1926 0.001 0.000 1927 0.001 0.000 1928 0.001 0.000 1929 0.002 0.000 1930 0.001 0.000 1931 0.001 0.000 1932 0.001 0.000 1933 0.001 0.000 1934 0.003 0.000 1935 0.001 0.000 1936 0.002 0.000 1937 0.001 0.000 1938 0.001 0.000 1939 0.000 0.000 1940 0.001 0.000 1941 0.001 0.000 1942 0.002 0.000 1943 0. oloo 0.000 1944 0.002 0.000 1945 0.001 0.000 1946 0.001 0.000 1947 0.001 0.000 1948 0.002 0.000 1949 0.002 0.000 1950 0.001 0.000 1951 0.001 0.000 1952 0.004 0.000 1953 0.003 0.000 1954 0.001 0.000 1955 0.001 0.000 1956 0.001 0.000 1957 0.001 0.000 1958 0.003 0.000 1959 0.002 0.000 1960 0.001 0.000 1961 0.002 0.000 1962 0.001 0.000 1963 0.000 0.000 1964 0.001 0.000 1965 0.002 0.000 1966 0.000 0.000 1967 0.001 0.000 1968 0.001 0.000 1969 0.001 0.000 1970 0.002 0.000 1971 0.003 0.000 1972 0.002 0.005 1973 0.002 0.000 1974 0.001 0.000 1975 0.003 0.000 1976 0.001 0.000 1977 0.001 0.000 1978 0.002 0.000 1979 0.001 0.000 1980 0.001 0.000 1981 0.001 0.000 1982 0.001 0.000 1983 0.002 0.000 1984 0.000 0.000 1985 0.001 0.000 1986 0.001 0.000 1987 0.002 0.000 1988 0.001 0.000 1989 0.001 0.000 1990 0.001 0.000 1991 0.001 0.000 1992 0.002 0.000 1993 0.001 0.000 1994 0.002 0.000 1995 0.001 0.000 1996 0.003 0.000 1997 0.001 0.000 1998 0.001 0.000 1999 0.000 0.000 I 2000 0.001 0.000 2001 0.001 0.000 2002 0.002 0.000 2003 0.001 0.000 2004 0.001 0.000 2005 0.002 0.000 2006 0.001 0.000 2007 0.001 0.000 2008 0.001 0.000 2009 0.001 0.000 2010 0.001 0.000 2011 0.001 0.000 2012 0.001 0.000 2013 0.001 0.000 2014 0.001 0.000 2015 0-003 0.000 2016 0.000 0.000 2017 0.002 0.000 2018 0.004 0.000 2019 0.004 0.000 2020 0.001 0.000 2021 0.002 0.000 2022 0.001 0.000 2023 0.001 0.000 2024 0.005 0.000 2025 0.001 0.000 2026 0.002 0.000 2027 0.001 0.000 2028 0.000 0.000 2029 0.001 0.000 2030 0.003 0.000 2031 0.001 0.000 2032 0.001 0.000 2033 0.001 0.000 2034 0.001 0.000 2035 0-003 0.000 2036 0.002 0.000 2037 0.000 0.000 2038 0.002 0.000 2039 0.000 0.000 2040 0.001 0.000 2041 0.001 0.000 2042 0.003 0.000 2043 0.001 0.000 2044 0.002 0.000 2045 0.001 0.000 2046 0.001 0.000 2047 0.001 0.000 2048 0.001 0.000 2049 0.001 0.000 2050 0.001 0.000 2051 0.001 0.000 2052 0.001 0.000 2053 0.001 0.000 2054 0.002 0.000 2055 0.000 0.000 2056 0.000 0.000 2057 0.001 0.000 2058 0.001 0.000 Stream Protection Duration Ranked Annual Peaks for Predeveloped and Mitigated. POC #1 Rank Predeveloped Mitigated 1 0.0050 0.0054 2 0.0045 0.0000 3 0.0041 0.0000 4 0.0040 0.0000 5 0.0037 0.0000 6 0.0033 0.0000 7 0.0033 0.0000 8 0.0031 0.0000 9 0.0030 0.0000 10 0.0029 0.0000 11 0.0028 0.0000 12 0.0028 0.0000 13 0.0027 0.0000 14 0.0026 0.0000 15 0.0025 0.0000 16 0.0024 0.0000 17 0.0024 0.0000 18 0.0024 0.0000 19 0.0023 0.0000 20 0.0023 0.0000 21 0.0022 0.0000 2.2 0.0022 0.0000 23 0.0021 0.0000 24 0.0021 0.0000 25 0.0021 0.0000 26 0.0020 0.0000 27 0.0020 0.0000 28 0.0020 0.0000 29 0.0019 0.0000 30 0.0019 0.0000 31 0.0019 0.0000 32 0.0019 0.0000 33 0.0018 0.0000 34 0.0018 0.0000 35 0.0018 0.0000 36 0.0017 0.0000 37 0.0016 0.0000 38 0.0016 0.0000 39 0.0016 0.0000 40 0.0016 0.0000 41 0.0016 0.0000 42 0.0015 0.0000 43 0.0015 0.0000 44 0.0015 0.0000 45 0.0015 0.0000 46 0.0014 0.0000 47 0.0014 0.0000 48 0.0014 0.0000 49 0.0014 0.0000 50 0.0014 0.0000 51 0.0014 0.0000 52 0.0014 0.0000 53 0.0013 0.0000 54 0.0013 0.0000 55 0.0013 0.0000 56 0.0013 0.0000 57 0.0013 0.0000 58 0.0013 0.0000 59 0.0013 0.0000 60 0.0013 0.0000 61 0.0013 0.0000 62 0.0013 0.0000 63 0.0012 0.0000 64 0.0012 0.0000 65 0.0012 0.0000 66 0.0012 0.0000 67 0.0012 0.0000 68 0.0012 0.0000 69 0.0012 0.0000 70 0.0012 0.0000 71 0.0012 0.0000 72 0.0011 0.0000 73 0.0011 0.0000 74 0.0011 0.0000 75 0.0011 0.0000 76 0.0011 0.0000 77 0.0011 0.0000 78 0.0011 0.0000 79 0.0011 0-0000 80 0.0011 0.0000 81 0.0011 0.0000 82 0.0011 0.0000 83 0.0011 0.0000 84 0.0011 0.0000 85 0.0011 0.0000 86 0.0011 0.0000 87 0.0011 0.0000 88 0.0010 0.0000 89 0.0010 0.0000 90 0.0010 0.0000 91 0.0010 0.0000 92 0.0010 0.0000 93 0.0010 0.0000 94 0.0010 0.0000 95 0.0010 0.0000 96 0.0010 0.0000 97 0.0010 0.0000 98 0.0009 0.0000 99 0.0009 0.0000 100 0.0009 0.0000 101 0.0009 0.0000 102 0.0009 0.0000 103 0.0009 0.0000 104 0.0009 0.0000 105 0.0009 0.0000 106 0.0009 0.0000 107 0.0009 0.0000 -J, r 108 0.0008 0.0000 109 0.0008 0.0000 110 0.0008 0.0000 ill 0.0008 0.0000 112 0.0008 0.0000 113 0.0008 0.0000 114 0.0008 0.0000 lis 0.0008 0.0000 116 0.0008 0.0000 117 0.0008 0.0000 118 0.0007 0.0000 119 0.0007 0.0000 120 0.0007 0.0000 121 0.0007 0.0000 122 0.0007 0.0000 123 0.0007 0.0000 124 0.0007 0.0000 125 0.0007 0.0000 126 0.0007 0.0000 127 0.0007 0.0000 128 0.0006 0.0000 129 0.0006 0.0000 130 0.0006 0.0000 131 0.0006 0.0000 132 0.0006 0.0000 133 0.0006 0.0000 134 0.0006 0.0000 135 0.0006 0.0000 136 0.0006 0.0000 137 0.0005 0.0000 138 0.0005 0.0000 139 0.0005 0.0000 140 0.0005 0.0000 141 0.0005 0.0000 142 0.0005 0.0000 143 0.0005 0.0000 144 0.0005 0.0000 145 0.0005 0.0000 146 0.0005 0.0000 147 0.0004 0.0000 148 0.0004 0.0000 149 0.0004 0.0000 150 0.0004 0.0000 151 0.0004 0.0000 152 0.0003 0.0000 153 0.0002 0.0000 154 0.0002 0.0000 155 0.0001 0.0000 156 0.0001 0.0000 157 0.0000 0.0000 Stream Protection Duration POC #1 The Facility PASSED The Facility PASSED. ,_J Flow(cfs) Predev Mit Percentage Pass/Fail 0.0006 12743 2 0 Pass 0.0006 11578 2 0 Pass 0-0006 10532 2 0 Pass 0.0007 9605 2 0 Pass 0.0007 8792 2 0 Pass 0.0007 8076 2 0 Pass 0.0008 7440 2 0 Pass 0-0008 6858 2 0 Pass 0.0008 6306 2 0 Pass 0.0008 5822 2 0 Pass 0-0009 5341 2 0 Pass 0.0009 4915 2 0 Pass 0-0009 4524 2 0 Pass 0.0009 4167 2 0 Pass 0-0010 3845 2 0 Pass 0.0010 3547 2 0 Pass 0.0010 3274 2 0 Pass 0.0010 3031 2 0 Pass 0.0011 2809 2 0 Pass 0.0011 2615 2 0 Pass 0.0011 2446 2 0 Pass 0-0011 2291 2 0 Pass 0.0012 2121 2 0 Pass 0.0012 1986 2 0 Pass 0.0012 1870 2 0 Pass 0-0012 1762 2 0 Pass 0.0013 1652 2 0 Pass 0-0013 1562 2 0 Pass 0.0013 1478 2 0 Pass 0.0014 1393 2 0 Pass 0-0014 1324 2 0 Pass 0-0014 1245 2 0 Pass 0.0014 1173 2 0 Pass 0.0015 1120 2 0 Pass 0.0015 1054 2 0 Pass 0.0015 1001 2 0 Pass 0.0015 953 2 0 Pass 0.0016 905 2 0 Pass 0.0016 868 2 0 Pass 0.0016 833 2 0 Pass 0.0016 800 2 0 Pass 0.0017 774 2 0 Pass 0.0017 740 2 0 Pass 0.0017 717 2 0 Pass 0.0017 688 2 0 Pass 0.0018 659 2 0 Pass 0.0018 631 2 0 Pass 0.0018 600 2 0 Pass 0.0018 564 2 0 Pass 0.0019 539 2 0 Pass 0.0019 511 2 0 Pass 0.0019 487 2 0 Pass 0.0020 464 2 0 Pass 0.0020 447 2 0 Pass 0.0020 435 2 0 Pass 0.0020 412 2 0 Pass 0.0021 399 2 0 Pass 0.0021 375 2 0 Pass 0.0021 360 2 0 Pass 0.0021 343 2 0 Pass 0.0022 326 2 0 Pass 0.0022 309 2 0 Pass 0.0022 292 2 0 Pass 0.0022 279 2 0 Pass 0.0023 264 2 0 Pass 0.0023 254 2 0 Pass 0.0023 237 2 0 Pass 0.0023 225 2 0 Pass 0-0024 214 2 0 Pass 0.0024 203 2 0 Pass 0.0024 186 2 1 Pass 0.0024 176 2 1 Pass 0.0025 166 2 1 Pass 0.0025 156 2 1 Pass 0.0025 140 2 1 Pass 0.0026 128 2 1 Pass 0-00,46 120 2 1 Pass 0.0026 112 2 1 Pass 0.0026 99 2 2 Pass 0.0027 95 2 2 Pass 0.0027 84 2 2 Pass 0.0027 79 2 2 Pass 0-0027 78 2 2 Pass 0.0028 73 2 2 Pass 0.0028 66 2 3 Pass 0.0028 61 2 3 Pass 0-0028 54 2 3 Pass 0.0029 47 2 4 Pass 0.0029 43 2 4 Pass 0.0029 39 2 5 Pass 0-0029 36 2 5 Pass 0-0030 34 2 5 Pass 0.0030 31 2 6 Pass 0.0030 29 2 6 Pass 0.0030 27 2 7 Pass 0.0031 27 2 7 Pass 0.0031 25 2 8 Pass 0.0031 21 2 9 Pass 0.0032 21 2 9 Pass 0.0032 19 2 10 Pass Water Quality BMP Flow and Volume for POC #1 On-line facility volume: 0.0063 acre-feet On-line facility target flow: 0.0088 cfs. Adjusted for 15 min: 0.0099 cfs. Off-line facility target flow: 0.005 cfs. Adjusted for 15 min: D.0056 cfs. LID Report LID Technique Used for Total Volumn Volumn Infiltration Cumulative Percent Water Quality Percent Comment Treatment? Needs Through Volumn Volumn Volumn Water Quality Treatment Facility (ac-ft.) Infiltration Infiltrated Treated (ac-ft) (ac-ft) Credit Gravel Trench Bed 1 POC N 24.20 N 98.83 Total Volume Infiltrated 24.20 0.00 0.00 98.83 0.00 0% No Treat. Credit Compliance with LID Standard 8 Duration Analysis Result = Passed Per1nd and ImpInd Changes No changes have been made. This program and accompanying documentation are provided 'as -is' without warranty of any kind. The entire risk regarding the performance and results of this program is assumed by End User. Clear Creek Solutions Inc. and the governmental licensee or sublicensees disclaim all warranties, either expressed or implied, including but not limited to implied warranties of program and accompanying documentation - In no event shall Clear Creek Solutions Inc. be liable for any damages whatsoever (including without limitation to damages for loss of business profits, loss of business information, business interruption, and the like) arising out of the use of, or inability to use this program even if Clear Creek Solutions Inc. or their authorized representatives have been advised of the possibility of such damages. Software Copyright 0 by : Clear Creek Solutions, Inc. 2005-2018; All Rights Reserved. DryweU OB Lovell-Sauerland and Associates 921 Pine Street Final Drainage Report -RI Ju�v 2018 LS4 No.5677 WWE[142012 PROJECT REPORT Project Name: Drywell #3B - Lot 3 DW+Joint Access Site Name: LSA #5677 Site Address: 921 Pine Street city : Edmonds Report Date: 1/14/2018 MGS Regoin : Puget East Data Start : 1901/10/1 Data End : 2058/09/30 DOT Data Number: 03 Version Date: 2017/04/14 Version : 4.2.13 Low Flow Threshold for POC 1 50 Percent of the 2 Year High Flow Threshold for POC 1: 50 year PREDEVFMOPED LAND USE Name Basin 1 Bypass: No GroundWater: No Pervious Land Use acre C, Forest, Mod .6il Pervious Total 0.041 Impervious Land Use acre Impervious Total 0 Basin Total 0.041 Element Flows To: Surface Interflow Groundwater MITIGATED LAND USE Name : Basin 1 Bypass: No GroundWater: No Pervious Land Use acre Pervious Total 0 Impervious Land Use acre DRIVEWAYS MOD 0.041 Impervious Total 0.041 Basin Total 0.041 Element Flows To: Surface Interflow Groundwater Gravel Trench Bed 1 Gravel Trench Bed I Na Gravel Trench Bed 1 Bottom Length: 12.00 ft. Bottom Width: 12.00 ft. Trench bottom slope 1: 0 To 1 Trench Left side slope 0: 0 To 1 Trench right side slope 2: 0 To 1 Material thiclmess of first layer: 2.5 Pour Space of material for first layer: 0.3 Material thiclmess of second layer: 0 Pour Space of material for second layer: 0 Material thic)mess of third layer: 0 Pour Space of material for th-ird layer: 0 Infiltration On Infiltration rate: 3.8 Infiltration safety factor: 1 Total Volume Infiltrated (ac-ft.): 15.656 Total Volume Through Riser (ac-ft.): 0 Total Volume Through Facility (ac-ft.): 15.656 Percent Infiltrated: 100 Total Precip Applied to Facility: 0 Total Evap From Facility: 0 Discharge Structure Riser Height: 2.5 ft. Riser Diameter: 6 in. Element Flows To: Outlet 1 Outlet 2 Gravel Trench Bed Hydraulic Table Stage(feet) Axea(ac.) Volume(ac-ft.) Discharge(cfs) Infilt(cfs) 0.0000 0.003 0.000 0.000 0.000 0.0389 0.003 0.000 0.000 0.012 0.0778 0.003 0.000 0.000 0.012 0.1167 0.003 0.000 0.000 0.012 0.1556 0.003 0.000 0.000 0.012 0.1944 0.003 0.000 0.000 0.012 0.2333 0.003 0.000 0.000 0.012 0.2722 0.003 0.000 0.000 0.012 0.3111 0.003 0.000 0.000 0.012 0.3500 0.003 0.000 0.000 0.012 0.3889 0.003 0.000 0.000 0.012 0.4278 0.003 0.000 0.000 0.012 0.4667 0.003 0.000 0.000 0-012 0.5056 0.003 0.000 0.000 0.012 0.5444 0.003 0.000 0.000 0.012 0.5833 0.003 0.000 0.000 0.012 0-6222 0.003 0.000 0.000 0-012 0.6611 0.003 0.000 0.000 0.012 0.7000 0.003 0.000 0.000 0-012 0.7389 0.003 0-000 0.000 0-012 0.7778 0.003 0.000 0.000 0.012 0.8167 0.003 0.000 0.000 0-012 0.8556 0.003 0.000 0.000 0.012 0.8944 0.003 0.000 0.000 0-012 0.9333 0.003 0.000 0.000 0.012 0.9722 0.003 0.001 0.000 0.012 1.0111 0.003 0.001 0.000 0.012 1.0500 0.003 0.001 0-000 0.012 1.0889 0.003 0.001 0.000 0-012 1.1278 0.003 0.001 0.000 0.012 1.1667 0.003 0.001 0.000 0.012 1.2056 0.003 0.001 0.000 0.012 1.2444 0.003 0.001 0.000 0.012 1.2833 0.003 0.001 0.000 0.012 1.3222 0.003 0.001 0.000 0.012 1.3611 0.003 0-001 0.000 0-012 1.4000 0.003 0.001 0.000 0.012 1.4389 0.003 0.001 0.000 0.012 1.4778 0.003 0.001 0.000 0.012 1.5167 0.003 0.001 0.000 0.012 1.5556 0.003 0.001 0.000 0-012 1.5944 0.003 0.001 0.000 0.012 1.6333 0.003 0.001 0.000 0.012 1.6722 0.003 0.001 0.000 0.012 1.7111 0.003 0.001 0.000 0.012 1.7500 0.003 0.001 0.000 0.012 1.7889 0.003 0.001 0.000 0.012 1.8278 0.003 0.001 0.000 0.012 1.8667 0.003 0.001 0.000 0.012 1.9056 0.003 0.001 0.000 0.012 1.9444 0.003 0.001 0.000 0.012 1.9833 0.003 0.002 0.000 0.012 2.0222 0.003 0.002 0.000 0.012 2.0611 0.003 0.002 0.000 0.012 2.1000 0.003 0.002 0.000 0.012 2.1389 0.003 0.002 0.000 0.012 2.1778 0.003 0.002 0.000 0.012 2.2167 0.003 0.002 0.000 0.012 2.2556 0.003 0.002 0.000 0.012 2.2944 0.003 0.002 0.000 0.012 2.3333 0.003 0.002 0.000 0.012 2.3722 0.003 0.002 0.000 0.012 2.4111 0.003 0.002 0.000 0.012 2.4500 0.003 0.002 0.000 0.012 2.4889 0.003 0.002 0.000 0.012 2.5278 0.003 0.002 0.024 0.012 2.5667 0.003 0.002 0.090 0.012 2.6056 0.003 0.002 0.172 0.012 2.6444 0.003 0.003 0.255 0.012 2.6833 0.003 0.003 0.324 0.012 2.7222 0.003 0.003 0.369 0.012 2.7611 0.003 0.003 0.402 0.012 2.8000 0.003 0.003 0.431 0-012 2.8389 0.003 0.003 0.458 0.012 2.8778 0.003 0.003 0.484 0.012 2.9167 0.003 0.003 0.508 0.012 2-9556 0.003 0.004 0.531 0.012 2.9944 0.003 0.004 0.553 0.012 3.0333 0.003 0.004 0.575 0.012 3.0722 0.003 0.004 0.595 0.012 3.1111 0.003 0.004 0.615 0.012 3.1500 0.003 0.004 0.634 0.012 3.1889 0.003 0.004 0.653 0.012 3.2278 0.003 0.004 0.671 0.012 3.2667 0.003 0.005 0.689 0.012 3.3056 0.003 0.005 0.706 0.012 3.3444 0.003 0.005 0.723 0.012 3.3833 0.003 0.005 0.740 0.012 3.4222 0.003 0.005 0.756 0.012 3.4611 0.003 0.005 0.771 0.012 3.5000 0.003 0.005 0.787 0.012 ANALYSIS RESULTS Stream Protection Duration Predeveloped Landuse Totals for POC #1 Total Pervious Area:0.041 Total Impervious Area:0 Mitigated Landuse Totals for POC #1 Total Pervious Area:O Total Impervious Area:0.041 Flow Frequency Return Periods for Predeveloped. POC #1 Return Period Flow(cfs) 2 year 0.000644 5 year 0.001091 10 year 0.001407 25 year 0.001933 50 year 0.00236 100 year 0.002631 Flow Frequency Return Periods for Mitigated. POC #1 Return Period Flow(cfs) 2 year 0 5 year 0 10 year 0 25 year 0 50 year 0 100 year 0 Stream Protection Duration Annual Peaks for Predeveloped and Mitigated. POC #1 Year Predeveloped Mitigated 1902 0.001 0.000 1903 0.000 0.000 1904 0.001 0.000 1905 0.000 0.000 1906 0.000 0.000 1907 0.001 0.000 1908 0.001 0.000 1909 0.001 0.000 1910 0.001 0.000 1911 0.001 0-000 1912 0.003 0.000 1913 0.001 0.000 1914 0-000 0.000 1915 0.000 0.000 1916 0.001 0.000 1917 0.000 0.000 1918 0.001 0.000 1919 0.000 0.000 1920 0.001 0.000 1921 0.001 0.000 1922 0.001 0.000 1923 0.001 0.000 1924 0.000 0.000 1925 0.000 0.000 1926 0.001 0.000 1927 0.001 0.000 1928 0.000 0.000 1929 0.001 0.000 1930 0.001 0.000 1931 0.001 0.000 1932 0.000 0.000 1933 0.001 0.000 1934 0.002 0.000 1935 0.001 0.000 1936 0.001 0.000 1937 0.001 0.000 1938 0.001 0.000 1939 0.000 0.000 1940 0.001 0.000 1941 0.001 0.000 1942 0.001 0.000 1943 0.000 0-000 1944 0.001 0.000 1945 0.001 0.000 1946 0.0101 0.000 1947 0.000 0.000 1948 0.001 0.000 1949 0.001 0.000 1950 O.Orol 0.000 1951 0.001 0.000 1952 0.002 0.000 1953 0.002 0.000 1954 0.001 0.000 1955 0.000 0.000 1956 0.000 0.000 1957 0.001 0.000 1958 0.002 0.000 1959 0.001 0-000 1960 0.000 0.000 1961 0.001 0.000 1962 0.001 0.000 1963 0.000 0.000 1964 0.001 0.000 1965 0.001 0.000 1966 0.000 0.000 1967 0.001 0.000 1968 0.001 0.000 1969 0.000 0.000 1970 0.001 0.000 1971 0.001 0.000 1972 0.001 0.002 1973 0.001 0.000 1974 0.001 0.000 1975 0.002 0.000 1976 0.001 0.000 1977 0.000 0.000 1978 0.001 0.000 1979 0.000 0.000 1980 0.001 0.000 1981 0.001 0.000 1982 0.000 0.000 1983 0.001 0.000 1984 0.000 0.000 1985 0.001 0.000 1986 0.001 0.000 1987 0.001 0.000 1988 0.001 0.000 1989 0.001 0.000 1990 0.001 0.000 1991 0.001 0.000 1992 0.001 0.000 1993 0.001 0.000 1994 0.001 0.000 1995 0.000 0.000 1996 0.002 0.000 1997 0.001 0.000 1998 0.001 0.000 1999 0.000 0.000 2000 0.000 0.000 2001 0.000 0.000 2002 0.001 0.000 2003 0.001 0.000 2004 0.001 0.000 2005 0.001 0.000 2006 0.000 0.000 2007 0.001 0.000 2008 0.001 0.000 2009 0.000 0.000 2010 0.000 0.000 2011 0.000 0.000 2012 0.001 0.000 2013 0.001 0.000 2014 0.000 0.000 2015 0-002 0.000 2016 0.000 0.000 2017 0.001 0.000 2018 0-002 0.000 2019 0.002 0.000 2020 0.001 0.000 2021 0.001 0.000 2022 0.000 0.000 2023 0.001 0.000 2024 0.003 0.000 2025 0.001 0.000 2026 0.001 0.000 2027 0.000 0.000 2028 0.000 0.000 2029 0.001 0.000 2030 0.002 0.000 2031 0-000 0.000 2032 0.000 0.000 2033 0.000 0.000 2034 0.000 0.000 2035 0.002 0.000 2036 0.001 0.000 2037 0.000 0.000 2038 0.001 0.000 2039 0.000 0.000 2040 0.000 0.000 2041 0.000 0.000 2042 0.002 0.000 2043 0.001 0.000 2044 0.001 0.000 2045 0.001 0.000 2046 0.001 0.000 2047 0.000 0.000 2048 0.001 0.000 2049 0.001 0.000 2050 0.000 0.000 2051 0.001 0.000 2052 0.000 0.000 2053 0.001 0.000 2054 0.001 0.000 2055 0.000 0.000 2056 0.000 0.000 2057 0.000 0.000 2058 0.001 0.000 Stream Protection Duration Ranked Annual Peaks for Predeveloped. and Mitigated. POC #1 Rank Predeveloped Mitigated 1 0.0030 0.0019 2 0.0026 0.0000 3 0.0024 0.0000 4 0.0023 0.0000 5 0.0022 0.0000 6 0.0019 0.0000 7 0.0019 0.0000 8 0.0018 0.0000 9 0.0017 0-0000 10 0.0017 0.0000 11 0.0017 0.0000 12 0.0016 0.0000 13 0.0016 0.0000 14 0.0015 0.0000 15 0.0015 0.0000 16 0.0014 0.0000 17 0.0014 0.0000 18 0.0014 0.0000 19 0.0013 0.0000 20 0.0013 0.0000 21 0.0013 0.0000 22 0.0013 0.0000 23 0.0012 0.0000 24 0.0012 0.0000 25 0.0012 0-0000 26 0.0012 0.0000 27 0.0012 0.0000 28 0.0012 0.0000 29 0.0011 0.0000 30 0.0011 0.0000 31 0.0011 0.0000 32 0.0011 0.0000 33 0.0011 0.0000 34 0.0011 0.0000 35 0-0010 0.0000 36 0.0010 0.0000 37 0.0010 0.0000 38 0.0010 0.0000 39 0.0010 0.0000 40 0.0009 0.0000 41 0.0009 0.0000 42 0.0009 0.0000 43 0.0009 0.0000 44 0.0009 0.0000 45 0.0009 0.0000 46 0.0008 0.0000 47 0.0008 0.0000 48 0.0008 0.0000 49 0.0008 0.0000 50 0.0008 0.0000 51 0.0008 0.0000 52 0.0008 0.0000 53 0.0008 0.0000 54 0.0008 0.0000 55 0.0008 0,0000 56 0.0008 0.0000 57 0.0008 0.0000 58 0.0007 0.0000 59 0.0007 0.0000 60 0.0007' 0.0000 61 0.0007 0.0000 62 0.0007 0.0000 63 0.0007 0.0000 64 0.0007 0.0000 65 0.0007 0.0000 66 0.0007 0.0000 67 0.0007 0.0000 68 0.0007 0.0000 69 0.0007 0.0000 70 0.0007 0.0000 71 0.0007 0.0000 72 0.0007 0.0000 73 0.0007 0.0000 74 0.0007 0.0000 75 0-0007 0.0000 76 0.0007 0.0000 77 0.0006 0.0000 78 0.0006 0.0000 79 0.0006 0.0000 80 0.0006 0.0000 81 0.0006 0.0000 82 0.0006 0.0000 83 0.0006 0.0000 84 0.0006 0.0000 85 0.0006 0.0000 86 0.0006 0.0000 87 0.0006 0.0000 88 0.0006 0.0000 89 0.0006 0.0000 90 0.0006 0.0000 91 0.0006 0.0000 92 0.0006 0.0000 93 0.0006 0.0000 94 0.0006 0.0000 95 0.0006 0.0000 96 0.0006 0.0000 97 0.0006 0.0000 98 0.0005 0.0000 99 0.0005 0.0000 100 0.0005 0.0000 101 0.0005 0.0000 102 0.0005 0.0000 103 0.0005 0.0000 104 0.0005 0.0000 105 0.0005 0.0000 106 0.0005 0.0000 107 0.0005 0.0000 108 0.0005 0.0000 109 0.0005 0.0000 110 0.0005 0.0000 ill 0.0005 0.0000 112 0.0005 0.0000 113 0.0005 0.0000 114 0.0005 0.0000 115 0.0005 0.0000 116 0.0005 0.0000 117 0.0004 0.0000 118 0.0004 0.0000 119 0.0004 0.0000 120 0.0004 0.0000 121 0.0004 0.0000 122 0.0004 0.0000 123 0.0004 0.0000 124 0.0004 0.0000 125 0.0004 0.0000 126 0.0004 0.0000 127 0.0004 0.0000 128 0.0004 0.0000 129 0-0004 0.0000 130 0.0004 0.0000 131 0.0003 0.0000 132 0.0003 0.0000 133 0.0003 0.0000 134 0.0003 0.0000 135 0.0003 0.0000 136 0.0003 0.0000 137 0.0003 0.0000 138 0.0003 0.0000 139 0.0003 0.0000 140 0.0003 0.0000 141 0.0003 0.0000 142 0.0003 0.0000 143 0.0003 0.0000 144 0.0003 0.0000 145 0.0003 0.0000 146 0.0003 0.0000 147 0.0003 0.0000 148 0.0003 0.0000 149 0.0002 0.0000 150 0.0002 0.0000 151 0.0002 0.0000 152 0.0002 0.0000 153 0.0001 0.0000 154 0.0001 0.0000 155 0.0001 0.0000 156 0.0000 0.0000 157 0.0000 0.0000 Stream Protection Duration POC #1 The Facility PASSED The Facility PASSED. Flow(cfs) Predev Mit Percentage Pass/Fail 0.0003 15304 3 0 Pass 0.0003 13370 3 0 Pass 0.0004 11695 3 0 Pass 0.0004 10358 3 0 Pass 0.0004 9127 3 0 Pass 0.0004 8149 3 0 Pass 0.0004 7275 3 0 Pass 0.0005 6499 3 0 Pass 0.0005 5838 3 0 Pass 0.0005 5193 3 0 Pass 0.0005 4645 3 0 Pass 0.0005 4176 3 0 Pass 0-0006 3746 3 0 Pass 0.0006 3351 3 0 Pass 0.0006 3014 3 0 Pass 0.0006 2733 3 0 Pass 0.0007 2495 3 0 Pass 0.0007 2285 3 0 Pass 0-0007 2070 3 0 Pass 0-0007 1899 3 0 Pass 0.0007 1753 2 0 Pass 0.0008 1607 2 0 Pass 0.0008 1490 2 0 Pass 0.0008 1380 2 0 Pass 0.0008 1282 2 0 Pass 0.0008 1186 2 0 Pass 0.0009 1101 2 0 Pass 0.0009 1031 2 0 Pass 0.0009 954 2 0 Pass 0.0009 897 2 0 Pass 0.0009 844 2 0 Pass 0.0010 802 2 0 Pass 0.0010 765 2 0 Pass 0.0010 724 2 0 Pass 0.0010 688 2 0 Pass 0.0010 647 2 0 Pass 0.0011 607 2 0 Pass 0.0011 563 2 0 Pass 0.0011 528 2 0 Pass 0.0011 497 2 0 Pass 0.0011 464 2 0 Pass 0.0012 442 1 0 Pass 0.0012 414 1 0 Pass 0.0012 394 1 0 Pass 0.0012 371 1 0 Pass 0.0012 343 1 0 Pass 0.0013 326 1 0 Pass 0.0013 302 1 0 Pass 0.0013 283 1 0 Pass 0.0013 258 1 0 Pass 0.0014 243 1 0 Pass 0.0014 226 1 0 Pass 0.0014 209 1 0 Pass 0.0014 192 1 0 Pass 0.0014 177 1 0 Pass 0.0015 162 1 0 Pass 0.0015 147 1 0 Pass 0.0015 128 1 0 Pass 0.0015 117 1 0 Pass 0.0015 102 1 0 Pass 0.0016 92 1 1 Pass 0.0016 84 1 1 Pass 0-0016 79 1 1 Pass 0.0016 73 1 1 Pass 0.0016 64 1 1 Pass 0.0017 57 1 1 Pass 0-0017 47 1 2 Pass 0.0017 43 1 2 Pass 0-0017 38 1 2 Pass 0.0017 34 1 2 Pass 0-0018 31 1 3 Pass 0.0018 27 1 3 Pass 0.0018 27 1 3 Pass 0.0018 22 1 4 Pass 0.0018 21 1 4 Pass 0.0019 17 0 0 Pass 0.0019 16 0 0 Pass 0.0019 13 0 0 Pass 0-0019 12 0 0 Pass 0-0019 10 0 0 Pass 0-0020 10 0 0 Pass 0.0020 10 0 0 Pass 0.0020 10 0 0 Pass 0.0020 10 0 0 Pass 0.0021 10 0 0 Pass 0.0021 10 0 0 Pass 0.0021 9 0 0 Pass 0-0021 9 0 0 Pass 0.0021 9 0 0 Pass 0.0022 9 0 0 Pass 0-0022 9 0 0 Pass 0.0022 8 0 0 Pass 0.0022 7 0 0 Pass 0.0022 7 0 0 Pass 0.0023 7 0 0 Pass 0.0023 6 0 0 Pass 0-0023 5 0 0 Pass 0.0023 5 0 0 Pass 0.0023 4 0 0 Pass 0.0024 4 0 0 Pass Water Quality BMP Flow and Volume for POC #1 on-line facility volume: 0.0037 acre-feet on-line facility target flow: 0.0056 cfs. Adjusted for 15 min: 0.0064 cfs. Off-line facility target flow: 0.0032 cfs. Adjusted for 15 min: 0.0036 cfs. LID Report LID Technique Used for Total Volumn Volumn Infiltration Cumulative Percent Water Quality Percent Comment Treatment? Needs Through Volumn Volumn Volumn Water Quality Treatment Facility (ac-ft.) Infiltration Infiltrated Treated (ac-ft) (ac-ft) Credit Gravel Trench Bed I POC N 14.44 N 98.67 Total Volume Infiltrated 14.44 0.00 0-00 98.67 0.00 0% No Treat- Credit Compliance with LID Standard 8 Duration Analysis Result = Passed Per1nd and Imp1nd Changes No changes have been made. This program and accompanying documentation are provided 'as -is' without warranty of any kind. The entire risk regarding the performance and results of this program is assumed by End User. Clear Creek Solutions Inc. and the governmental licensee or sublicensees disclaim all warranties, either expressed or implied, including but not limited to implied warranties of program and accompanying documentation. In no event shall Clear Creek Solutions Inc. be liable for any damages whatsoever (including without limitation to damages for loss of business profits, loss of business information, business interruption, and the like) arising out of the use of, or inability to use this program even if Clear Creek Solutions Inc. or their authorized representatives have been advised of the possibility of such damages. Software Copyright 0 by : Clear Creek Solutions, Inc. 2005-2018; All Rights Reserved- Section D Grading and Erosion Control Summary Lovell-Saiterland and Associates Final Drainage Report -RI LSA No. 5677 921 Pine Street July -7018 GRADING AND EROSION CONTROL SUMAM Y.- The project will require moderate grading in order to construct the proposed single family residences and associated site paving. Standard erosion control measures are proposed to be used during construction. The primary erosion and sediment control 'Test Management Practice" (BMP) during construction will be proper soil stabilization methods. Exposed soils shall be stabilized by application of effective BMP's that protect the soil from the erosive forces of raindrops, flowing water, and wind. Appropriate BMPs 'include, but not limited to, temporary and permanent seeding, sodding, mulching, plastic covering, erosion control fabrics, matting, soil application ofpolyacrylamide (PAM), the early application of gravel base on areas to be paved, and dust control. The contractor shall select a soil stabilization method best suited for the particular situation. Stock piles must be stabilized and protected with sediment trapping measures. In addition, site containment of exposed soils shall be sustained by usig silt fence barriers along the down -slope boundaries of the site's disturbance areas. Soil Types: Alderwood-Urban Land Complex, 2-8 % slopes Hydrologic Group ='T" The grading amounts associated with the project have been approximated as shown below. The quantities listed are for the permitting process only and should not be considered precise amounts for bidding purposes. The estimated quantities for short plat inprovements grading arc: Approximate Cut: 175 CY Approximate Fifl: 175 CY Included in the submitted site development construction plans are specific proposed grades and drainage improvement notes and details. With proper installation, maintenance and inspection of the proposed construction, the project should have minimal impact to the surrounding environment. Lovell-Sauerland and Associates 921 Pine Street Final Drainage Report RI July 2018 LSA No.5677 I " Lovell-Sauerland and Associates Final Drainage Reporl-RI LSA No. 5677 Section E Operation and Maintenance L.== 921 Pine Street July 2018 OPERATION AND MAINTENANCE GUIDELINES: Operation and Maintenance Requirements: These guidelines are intended to provide operation and maintenance 'instruction for the new single family residences located at 921 Pine Street and their storm drainage control facilities. The owners are responsible for maintenance of storm drainage facilities within their individual properties. Owners are not responsible for maintenance within the public night -of -way. This manual is not comprehensive. Although it explains the intended operation of the various components of the drainage system, and suggests a routine of inspection and maintenance, it cannot anticipate every problem. Once a historical record of maintenance is established, it may be prudent to alter the routine. It is recommended that maintenance records be kept, and that the records be reviewed periodically. Concept of Operation: The drainage design is shown and described in the site development engineering plans and report. The approved site development plans and report should be retained by the owner and used as a reference to identify drainage facilities outlined in this manual. Conveyance Systems. The design objective in pipe sizing was to convey the I 0-year storm V"ithout the water surface exceeding the overflow elevation of the proposed facilities. Frequent overtopping of the pipe system in a particular area might indicate a downstream blockage. Overtopping of the drain systems at the yard drains or cleanouts is an indication that maintenance is required. Recommended iWections of Facilities. The following are inspection guidelines for the drainage system. The inspections should occur prior to the winter rain season, leaving sufficient time to correct any detected maintenance problems, and at the end of the season to determine the effect of the season's runoff. Once a historical basis is developed the frequency of 'inspection may be modified as necessary. For additional and updated maintenance information visit the Washington State Department of Ecology's web -site at: htti): ec v. w a. gg-vL/R ro grams/w g /w Ahome.litm]. Lovell-Saiterland and Associates 921 Pine Street Final Drainage Report —RI Juty 2018 LSA No. 5677 L.MRM 4.6 Maintenance Standards for Drainage Facilities The facility -specific maintenance standards contained in this section are intended to be conditions for determining if maintenance actions are required as identified through inspection. They are not intended to be measures of the facility's required condition at all times between inspections. In other words, exceedence of these conditions at any time between inspections and/or maintenance does not automatically constitute a violation of these standards. However, based upon 'inspection observations, the inspection and maintenance schedules shall be adjusted to minimize the length of time that a facility is 'in a condition that requires a maintenance action. Table 4.5.2 Maintenance Standards No. I — Detention Ponds Deftct Conditions When Maintenance Is Results Expected When Nntenance Co ent Needed Maintenance Is Performed General Trash & Debris Any trash and debris which exceed 1 Trash and debris cleared site. cubic feet per 1,000 square feet. In general, there should be no v�sual evidence of dumping. If less than threshold all trash and debris will be removed as part of ne)d %QFheduled maintenance. Poisonous An 'sonous or nuisance danger of poisonous vegetation Vegetaton and vegeta which may constitute where maintenance personnel or the rpublic no)dous weeds hazard to . tenance pe or might normally be. (Coordinate the public. with local health department) Any evidence of no weeds as Complete eradication of no)dous weeds defined by State gulations. may not be possible. Compliance with (Apply requii en s of ado IPM State or local eradication policies policies e use of herbicide required Contaminants y evidence of oil, gasoline, No and Pollution contaminants or other pollutants (Coordinate removal/cleanup with local water quality response agency). OoKodent Holes Any evidence of rodent holes if Rodents destroyed an� m or berm facility is acting as a dam or berm, or e repaired. (Coordinat wit I health any evidence of water piping through department; coordinate vAA2 y �y dam or berm via rodent holes. Dam Safety Office if pond excee 0 acre-feet.) Vohime V — Runof Treatment BMPs — December 2014 4-32 No. 2 - Infiltration Maintenance Defect Conditions When Maintenance is Results Expected When Component Needed Maintenance Is Performed General Trash & Debris See "Detention Ponds" (No- 1)- See "Detention Ponds' (No- 1)- Poisonous/Noxious See"Detention Ponds'(No. 1). See "Detention Ponds" Vegetation (No, 1). Contaminants and See "Detention Ponds" (No. 1). See "Detention Ponds" Pollution (No. 1). Rodent Holes See "Detention Ponds' (No. 1). See "Detention Ponds" (No. 1) Storage Area Sediment Water ponding in infiltration pond after Sediment is removed rainfall ceases and appropriate time and/or facility is cleaned allowed for infiltration. Treatment basins so that infiltration system should infiltrate Water Quality Design Storm works according to Volume within 48 hours, and empty within design. 24 hours after cessation of most rain events. (A percolation test pit or test of facility indicates facility is only working at 90% of its designed capabilities- Test every 2 to 5 years. If two inches or more sediment is present, remove), Filter Bags (if Filled with Sediment and debris fill bag more than 112 Filter bag is replaced or applicable) Sediment and full- system is redesigned. Debris Rock Filters Sediment and By visual inspection, little or no water flows Gravel in rock filter is Debris through fifter during heavy rain storms, replaced. Side Slopes of Erosion See "Detention Ponds" (No- 1). See "Detention Ponds" Pond (No. 1). Emergency Tree Growth See "Detention Ponds" (No. 1). See *Detention Ponds" Overflow Spillway (No. 1). and Berms over 4 feet in height. Piping See"Detention Ponds"(No. 1). See "Detention Ponds* (No. 1). Emergency Rock Missing See *Detention Ponds" (No. 1). See "Detention Ponds" Overflow Spillway (No. 1). Erosion See 'Detention Ponds" (No- 1)- See "Detention Ponds* (No- 1)- Pre-settling Facility or sump 6" or designed sediment trap depth of Sediment is removed. Ponds and Vaults filled with Sediment sediment - and/or debris Volume V — Runoff Treatment BMPS — December 2014 4-35 No. 5 — Catch Basins Maintenance Defect Conditions When Maintenance is Needed Results Expected When Component Maintenance is performed General Trash & Trash or debris which is located immediately No Trash or debris located Debrs in front of the catch basin opening or is immediately in front of blocking inletting capacity of the basin by catch basin or on grate more than 10%. opening. Trash or debris (in the basin) that exceeds 60 No trash or debris in the percent of the sump depth as measured from catch basin. the bottom of basin to invert of the lowest pipe into or out of the basin, but in no case less than a minimum of six inches clearance from the debris surface to the invert of the lowest pipe. Trash or debris in any inlet or outlet pipe Inlet and outlet pipes free blocking more than 1/3 of its height- of trash or debris. Dead animals or vegetation that could No dead animals or generate odors that could cause complaints or dangerous gases (e.g., methane). vegetation present within the catch basin. Sediment Sediment (in the basin) that exceeds 60 No sediment in the catch percent of the sump depth as measured from basin the bottom of basin to invert of the lowest pipe into or out of the basin, but in no case less than a minimum of 6 inches clearance from the sediment surface to the invert of the lowest pipe. Structure Top slab has holes larger than 2 square Top slab is free of holes Damage to inches or cracks wider than 1/4 inch and cracks - Frame and/or Top Slab (Intent is to make sure no material is running into basin). Frame not sitting flush on top slab, Le., separation of more than 3/4 inch of the frame from the top slab. Frame not securely Frame is sitting flush on the riser rings or top slab and firmly attached. attached Fractures or Cracksin Maintenance person judges that structure is unsound- Basin replaced or repaired to design standards. Basin Walls/ Bottom Grout fillet has separated or cracked wider than 1/2 inch and longer than 1 foot at the Pipe is regrouted and secure at basin wall - joint of any inlet/outlet pipe or any evidence of soil particles entering catch basin through cracks, Settlement/ Misalignment If failure of basin has created a safety, function, or design problem. Basin replaced or repaired to design standards - Vegetation Vegetation growing across and blocking more than 10% of the basin opening- No vegetation blocking opening to basin. Vegetation growing in inlet/outlet pipe joints that is more than six inches tall and less than No vegetation or root growth present. six inches apart. Contamination See "Detention Ponds" (No. 1). No pollution present. and Pollution Volume V — Runoff Treatment BMPs — December 2014 4-38 No. 5 — Catch Basins Maintenance Component Defect Conditions When Maintenance is Needed Results Expected When Maintenance is performed Catch Basin Cover Cover Not in Place Cover is missing or only partially in place- Any open catch basin requires maintenance- Catch basin cover is closed Locking Mechanism Not Working Mechanism cannot be opened by one maintenance person vAth proper tools. Bolts into frame have less than 1/2 inch of thread. Mechanism openswith proper tools - Cover Difficult to Remove One maintenance person cannot remove lid after applying normal lifting pressure- Cover can be removed by one maintenance person - (intent is keep cover from sealing off access to maintenance.) Ladder Ladder Rungs Unsafe Ladder is unsafe due to missing rungs, riot securely attached to basin wall, misalignment, rust, cracks, or sharp edges, Ladder meets design standards and allows maintenance person safe access. Metal Grates (if Applicable) Grate opening Unsafe Grate with opening wider than 718 inch. Grate opening meets design standards - Trash and Debris Trash and debris that is blocking more than 20% of grate surface inletting capacity. Grate free of trash and debris - Damaged or Missing- Grate missing or broken member(s) of the grate- Grate is in place and meets design standards - No. 6 - Debris Barriers (e.g., Trash Racks) ance [7corm�pon Defect Condition When Maintenance is Needed Results Eqmted When Maintenance is General Trash or debris that is plugging more than 20% of the openings in the barrie Barrie to design flow Metal Damaged/ Missing Bars. Ba ent o �of shape mor�� jnches_� Bars in place with no bends more than 3/4 inch, Bars aAoReing—or enti Bars in place according to design. MOM Ba laced or repaired to design s & s. 7 ars Bars are loose and rust is causing 50% deteric deterioration to any part of barrier. InIpe /Outlet t/O P p ipe s Debris barrier missing or not attached to pipe pip Barrier firmly attaJ> �e Volume V— Runoff Treatment BMPs — December 2014 4-39 No. 18 - Catchbasin Inserts Maintenance Defect Conditions When Maintenance is Results Expected When Component Needed Maintenance is Performed General Sediment When sediment forms a cap over the No sediment cap on the insert Accumulation insert media of the insert and/or unit. media and its unit. Trash and Trash and debris accumulates on insert Trash and debris removed Debris unit creating a blockage/restriction. from insert unit. Runoff freely Accumulation flows into catch basin, Media Insert Not Effluent water from media �nseft has a Effluent water from media Removing Oil visible sheen. insert is free of oils and has no visible sheen. Media Insert Catch basin insert is saturated with water Remove and replace media Water Saturated and no longer has the capacity to insert absorb. Media Insert -Oil Media oil saturated due to petroleum spill Remove and replace media Saturated that drains into catch basin. insert. Media Insert Use Media has been used beyond the typical Remove and replace media at Beyond Normal average life of media insert product. regular intervals, depending on Product Life insert product. Vohime V — Runof f Treatment BMPs — December 2014 4-51 Appendix A Geotechnical Reports Lovell-Sauerland and Associates Final Drainage Report -RI LSA No. 5677 921 Pine Street July-70I8 Dennis M. Bruce, RE. _rl) AJ E_ ;� � I f� 0 1 Ir— M.S.C.E., M.B.A. Geotechnical /Civil Engineer Geotechnical Evaluation and Infiltration Rates Fairwinds Development 921 Pine St. This engineering report summarizes the geotechnical and infiltration evaluation of the site at 921 Pine St. Fairwinds Development proposes to construct 3 new single family homes on the overall property. See plans. In order to determine the possibility of on -site storm water management, 3 soil test pits were dug, evaluated, and in -situ infiltration tests were performed. Additionally, representative soil samples were tested in a grain size analysis to corroborate the field descriptions. All soil analyses verified that the native soils are : Sands. Design Infiltration Rate: Use of the State of Washington D.O.E. Manual allows for a determination of Infiltration Rate by soil texture evaluation. See attached laboratory sieve analysis of 2 samples. The grain size analysis verifies the category: Sand. Hence,the D.O.E. Manual allows for a short term infiltration rate of 8 hr. , which is to be modified by a Correction Factor of 4 to result in a Long Term ( or Design Rate) of 2 / hr. This "textural designation" method may be overruled by the more reliable method of in -situ infiltration testing. This engineer performed multiple in -situ infiltration tests of the native sands, using industry standard methods (see attached data). - The ACTUAL in -situ infiltration rates exceeded 30 " / hr. -Geotechnical guidelines recommend a Correction Factor of 2, which yields a Design Rate of 15 " / hr. -This engineer - based on decades of practical experience - recommends a Max. Design Rate of 10 " / hr. -Some Municipal Jurisdiction utilize a Correction Factor of 4, which yields a Design Rate of 7.5 "' / hr. Choose a Design Rate: An effective on site infiltration facility may be designed and built using any of the above Design Rates. If the particular governmental jurisdiction desires to mandate the Correction Factor of 4, the facility can easily be constructed in the native sands. Inspections: On site geotechnical inspections by this Engineer are reguired to: Verify actual subgrade conditions at the facility, verify geometry of the facility, verify material type and placement, and verify the storm line connections, per design. 4 Dennis M. Bruce, P.E. 0L"J>.C- Geotechnical / Civil Engineer SOILS * FOUNDATIONS - SITE DEVELOPMENT 0 INSPECT70N 0 DRAINAGE e DESIGN & PERMIT 0 LEGAL P.O. Box 55502' - Shoreline, WA 98155 - (206) 546-9217 - F-AX-ktge)-�� )(rV ro s\k �'TAT E7 VJ A - _�-rokmwAr-rEP- AAMukL v 5U for homogeneous soils. These rates not consider the effects of site variability and long-term clogging due to siltation and biomass buildup in tile infiltration facility. ck a, 'Pt&M �-( 5( a IOU. _re;6_r S A ti k�.. Table 3.7 - Recommended In filtration Rates based on USDA Soil Textural Classification. Estimated Long - *Short -Term Term (Design) Infiltration Correction Infiltration Rate Rate (inJhr) Factor, CF (inJhr) 'Clean sandy gravels and 20 2 gravelly sands (i.e-, 90% of the total soil sample is retained in the #10 sieve) Sand 8 4 2*** Loamy Sand 2 4 U Sandy Loam 1 4 025 Loam 0.5 4 0.13 *From WEHASCE� 1998. "Not recommended for treatment NOTE ACTOA L *"* Refer to SSC-4 and SSC-6 for treatment aoceptability criteria MFtLrRA-(IOOased on experience with long-term full-scale infiltration pond performance, Ecology's Technical Advisory Committee (TAQ —res TS V ei�_l r- I el recommends that the short-term infUtration rates be reduced as shown in Table 3.7, dividing by a correction factor of 2 to 4, depending on the soil (1dF(L-M_A-rkok) 'VATF-S temral clasIsification. The correction ffictors provided in Table 3.7 �30represent an average degree of long-term facility maintenance, TSS 'Xtat- reduction through pretreatment and site variability in the subsurface .��onditions. These conditions might include deposits of ancient landslide IlAos-re-Y C-rkNxAk debris buried stream channels, lateral grain size variability, and other h facto; that affect homogeneity). These correction factors could be reduced, subject to the approval of the -.6local jurisdiction, under the following conditions: 'T It /o a For sites with little soil variability, 0 Where there will be a high degree of long-term facility maintenance, -b'JP_UCE pe7. Where specific, reliable pretreatment is employed to reduce TSS .b6'St,O&) )kjk"rE 0 ')/tile entering the infiltration facility no caw shall a correction factor less than Z.0 be used. 1=AC'r0P-- kesuL-rs I" A ��e8(4,U '_PA-rG OP 3-76 Volume Ill - Hydrologic Analysis and How Control BMPs Febfuafy 2005 ,,,T#�j F- ;� 7 j R 0 17, - 6P,AW rkOA,l St---M ANA-LYSGS 0 F --) 0 (L- 0 VCE7911=:7E-A -rqe- 44JC41�7-10A) ----------------- - Ac,-rL)kL- [tj-�vrc) IA)rfL-rkATIOA) (V i e-h -64E TAPIts fivra- � kiwrErs or 6AOV,&. ry Dennis M. Bruce, P.E. \TVA) 5 M.S.C.E.,, M.B.A. Geotechnical /Civil Engineer T�-1*-c-SE71S ME-VJ T E-h MON &5—vi: .I- F A M I i -**Y a Or\ A A 117- - -rt Q C) A) 7E6"Ts This Infiltration Test was performed by. Company Name: 0 & (F Conlact Name: 1�4 Phone Number 0 10 S—A Email Address: L'Evtuce E'626AA A( L. 60M 2 Incl rude site map or drainage control plan, with test locations clearly marked. The intent of this checklist is to provide a summary of stormwater BMP subsurface investigation and infiltration tesbn( requirements associated with the Simple Subsurface Investigation. All projects and associated plans are also subject to the minimum requirements outlined in the City of Seattle Stormwater Manual and SMC Chapters 22.800 — 22.808, as well as the specific subsurface investigation and infiltration testing requirements outlined in Volume 3, Chapter 3 and Appendix D of the 2016 City of Seattle Stormwater Manual. TNs checkiiist does not preclude the use of professional judgment to evaluate and manage risk associated with design, construction, and operation of infiltration BMPs. See Appendix C for site constraints that may preclude infiltration facility feasibility for -some BMPs. The Simple Infiltration Test is not allowed for projects with no off -site p6int of discharge (Section 4.3.2.1). These projects shall use a Small Pilot Infiltration Test (PIT). Before you start call Utirity Locates 811 to request locates of utilities at your site. The Simple Subsurface Investigation involves an Infiltration Testing element and a Subsurface Investigation element. Although the infiltration Testing is listed first below, the Infiltration Testing and Subsurface Investigation can be done in any order. INFILTRATION TESTING: 1. Is the infiltration test within the footprint of the proposed infiltration facility? El,^s [KNo 2. If Onoo is the test within 50 feet of the proposed infiltration facility? Yes n No Explain why: 3. What is the total proposed new plus replaced impervious area (not including permeable pavement surfaces) 6 E-E -eIT5- PCAM V6 P— P P-0 P 0 5 E h A),F(kJ SOILS FOUNDATIONS SITE DEVELOPMENT INSPECTION DRAINAGE DESIGN & PERMIT LEGAL P.O. Box 55502 - Shoreline, WA 981,55 - �206) 546-9217 A A'� ("T 00 M A Y S-1 9,e) I q 4. Date and time of test(s): (0 ff performed November through March, one test is required. If performed April through October, two tests are required - Tests rn�_sfl; in the_rJm—e_--ho1e_w_J-tFin 2-days. The beginning of each test must be spaced 24-hours apart. 5. 2f /Dig an infiltration test hole at least 2-feet deep, measured from the proposed finished grade, and 2-feet across. It is recommended that the test hole depth be at the bottom of the facility to provide the best design information. (Note: this hole is separate fronvthe hole in Step 11 below) 6. Diameter of test hole (2-foot minimum): 6-)( -2 feet 7. Depth of test hole (2-foot minimum): &.0 . feet 8. Describe soil type and texture (e.g., sand, clay, gravel.): L 16WJ S A Uh-S 9. 'alk period a) Add water to th(�� (Measure depth using a ruler, scale, or tape measure). )S �b) Stabilize water depth fbr a minimum of 30-minutes by adding water untl the depth is mpFAeimed-at4____ minimum of 12 inches, then move on to step c. ALL (?, c) Stop adding water, then record the number of inches the water has fallen in 1 hour k�_� inches I IIJ d) Record the number of inches the water has fallen from hour 1 to hour 2: WA inches At 0 e) What is the smaller of the two numbers in row 9c and 9d above? (check only one box below) > 3-inches (Use Table I below — I 5-minute intervals-) Between 1 -inch and 3-inches (Use Table 2 below — 30-minute intervals.) < I -inch (Use Table 3 below — 60-minute intervals.) This is your "testrig period. 10. Testing period Based on the answer to 9e above, use either Table 1, 2 or 3 on the Results and Certification page to record your data and: *-Refill the hole to the 12-inch mark. Immediately record the time and depth of water in the appropriate table below. c) Based on your time interval (answer to 9e above): Record the time and depth of water in the hole at the specified intervals. Complete the table by recording six measurements (in addition to the starting depth). V If the hole empties p(w to the six measurements, refill to the 12-im;h mark and continue recording until you have completed We table. d) Using the depth of water recorded at each interval, calculate the infiltration rate and recoird the results. Table 1: Infiltration Rate = Change in depth between each interval x 4 Table 2- Infiltration Rate = Change in depth between each interval x 2 3- Infiltration Rate = Change in depth between each interval x 1 *T __e) If perFormed April through October, repeat steps 9 and 10 in the same hole 24 hours after the beginning of the first infiltration test and recordIft �resulis, 'in the Infiltration Test 92 Result tables- SUBS7Fg E INVESTIGATION: D hole to the depth required per Table 5 below and approximately 5-feet from the proposed infiltration facil4. (See the footnote at the end of Table 5 — depth is measured from the bottom of the proposed infiltration facility.) 12, Record total depth of hole from surrounding ground surface: 5­5 feet 13. While digging the hole, did you: a) Hit hard pan? (i.e. hardened soil that is like conicrete) Myes WyNoo b) Encounter standing water or seepage in the hole? L1 Yes 0 14. If you answered "yes" to either (I 3a) or (13b), infiltration is not feasible for this site. Testis finished. Page 2 OF TOG INFILTRATION TEST RESULTS AND CERTIFICATION Infiltration Test #1 Results Table I (15.rninl Tahlf% Vy', M ,nme (30-min) Depth of Water (In003) Infittrat] Rate (irdhr, 12 able 3 ( -min) Tinve Depth of Infiftdon (80-min) Water Pate anches) (irdhr) 12 Infilitratiorl(Te;st #02 Lsults (Required if performed April through Cctober - see step 4 above) rsF(t L., -V-V a'k 9 (15-min) Ta a 2 (30-m n) ThIne Depth of VwfiftmMon Water Rate (Inches) On/hr) 12 Table 3 (wnln) Time I Depthof Inifflftdon (N-min) I Water Rate 2?�� lowest infiltration rate from the tables above = Z �L, inthr (Measured infiltration rate) • IF ffie lowest measured irdiltratfon rate is less than the mWenum rate associated with an infiftration BMP (see Table 4 below), that BMP cannotbe used • IF 9w measured infiltrahon er 'PWI§ �, �lo t �7v v �r- --s U; �j -r 1E 0 r-- L o 40vr investigaffon is required.( (U'S5 r- — JE] Design infiltration rate = Measured infiltration rate x 0.5 inthr SIGNATURES ARE REQUIIRED I certify that I have followed the procedures outlined in this document to determine the infiltration BMP f6asibilit) and infiltration rate. Infiltration Test performed by; 'j, J�;-o tj t'� Print Name of Signature Date P-01 7 Subsurface Investigation performed by. 17405 Pdnt Name b I L U e re 1" �E ONAL Signature _ L2" - 'P, GT - Date r .P. � , f llr� Page 4 OF C.2.2 FULL INFTLTRATION IFIGURE CI.LA TYPICAL TRENCH INFILTRATION SYSnM I I %jt A k-e CLEFAW roof drain PLAN VIEW 4" rigid or 6" flexible perforated pipe r-DOTS (OrIG-rik-AT'100 ------------------------------------ ------------------------------- ------------------ infiltration trench sump whsolid lid, 0611�7 �LO LAOEAL� PT. Or- —C1t-1FUC-" o I ?- or tm p15 6r—Qtou-s ?.a-k ()000 IT PLAN VIEW jilroof drain NTS 11F MOTAL IAKV\)'00�5 w F T, C rigid or 6"flexible splash block us 1E peftrated pipe --- - ------- I ------------------------------------- S-V min washed rock �� 5\�- , ;. III: a �" P., 12" , "�� i� z — 0 r-, 0 o �, ; 11 1 10-W —10�0 — ------------------------------ - �v fine nesh OB sump w/soEd fid vanes- -rLAF— ToTAL .0il T(t903CA4 MAY '515 SPUT 03TO L64J6 TJd ;L Vivrw iAtmtmv&A fitter fabfic ----\ I compacted backfin 6EPAkA-r(OJU A- 6" 4' rigid or 6" flexible T perforated pipe 24" v 7 washed rock 12" J�/ MLMLMLA V, 1 1 Z-3/4' V SECTION A NTS Ty 7;�t-s AJ4 P 2009 Surface Water Design Manual — Appendix C 1/912009 C-45 921 Pine St, Soil Test Pits verify clean sand subgraide. All test pits verified native sands ( to depth of pit @ 7ft.) Clean sands — excellent for infiltration. Perform Infiltration Test. Rapid actual infiltration rate Actual measured infiltration rates exceeded 30 hour Use Design Rate = 10 " per Hour Maximum L L L c L L L 'L L R,3E., W.K CITY OF FOACAVS -qr' 915-L'44J*l tJrC0/7D.W M. 03041402-IJ AW A0. fir-OX0216) 4 m�ly "p APPUCANI ENr.NEER/SURVEYOR r.. ..... . .. 1,1111,11111 CIE F j 'A ---- ---------- WATER SERIACE PARCELNUMscA PROPERTY AREA F10 UCE PR07ECTION 7 P4 I I I .- . ll� — — .11 . — ,4 ole, PAJ, V3CRIP710N (FyTtRC PROPERry) -a- 04: � k Al2 � 0M 7W @ 19, IVTK' I U_T UTLN f I PRO FER7Y ADDRESS PUBLIC SCHOOLS r ZONINO FIRE PROTECTION ... ........ . re TELEPHONE 11 " SEWER SERMCE MOM* LLA 0, JO ELECTRICITY NATURAL GAS - - - - - - - - - - LEAENI) ----- - -------- 6. LoeA-r(Otj Or r � t _r TOPOGRAPHY SURVEY FOR SotL r.A IRWNDS DEVELOPMENT LLC IN NW1/4, NE1/4 SEC. 25, T.27N., R.3E.,W.M. CITY OF EDMONDS T-4 SNOHOMISH COUNTY, WASHINGTON 1 -Saverland & Am�isteo. too. LER Ml — r. 5;77-0-17 0 Dcnn ' is Bruce, 1R.E. 'q0t M.S.C,E. M.B.A. -Engineer City of Edmonds # PLN 20170033 This engineering report presents the results of additional geotechnical evaluation (more Test Pits, S mail PIT Infiltration Testing) at 921 Pine St. This additional testing was required by City of Edmonds Review Comments pertaining to the proposed development of 3 new S.F,R, Additional Soil Test pits: See Sits Plan depicting the Proposed 3 lots and the additional test pits dug October 10, 2017. One test pit was dug per lot (per layout on the Site Plan). Each Pit was dug to 6 ft. depth. Subsurface conditions are presented on the following Soil Logs: -Test Pit Lot I ( East portion of overall propertyl: 0 -8 " Lawn, roots, organic slit. 8" to 6.0 ft. (bottom of pit) Consistent Sands with Gravels. This entire zone is compatible with infiltration. - Test Pit Lot 2 : 0 -8 " Plant roots, organic silt 8" -3.0 ft. Sands with Gravels. This zone is compatible with infiltration, 3.0' — 6.0 ' increasingly silty sands grading into weathered Glacial Till. This zone is NOT compatible with infiltration, Test Pit Lot 3: 0 -8 " Plant roots,, organics, silt, 8" — 4 ft. Sands with Gravels, This zone is compatible with infiltration. 4 ft. - 6�O ft Increasingly silty sands grading into weathered Glacial Till. This zone is NOT 113 compatible with infiltration. See photo sheets of Test Pits and Infiltration Testing 90k3 0 F(',11NDA110A,S S1'FL;H&L0P,'fENT jNS..+C,j'yV 0 L)R AINAC'L 6 P, P 0 Box 55502 St-cire i ie INA c)B I 5f-' - 206) 546-9217 - I � Addi ional infiltration Tesjjn�hree new test pits were dug to 6 ft. depths on October 10, 2017. Each Pit was filled to a minimum of 18 inch depth with water to establish the Pre -Soak condition per City of Edmonds approved Small PIT procedures (attached). Actual Testing began the following day ( October 11, 2017) — performing the Small PIT test on each Test Pit. ............ I ........................... .1, .......................................................... I— ................. ...... I ...... . ...................... The eastern Pit (Lot #,) had verified sands with gravels for the_gBLire 6ft. depth of pit. I -his consistent condition. Actual infiltration Rates exceeded 16 inches per hour. The Infiltratior, TeS+ verifiedt. This condition ( clear observable soils that are consistent throughout the entire pit) AND actual test resuits verifying excellent infiltration rates APPROVE this Lot 4 .1 zone for an Infiltrat'ion Facility, L USE: A Design Rate = 9r' per Hr. for facilities in this area, ................ ........ ............. Lot # 2 pit and test: The pit on Lot #2 encountered clean sands and gravels in the upper 3.0 ft, However, soil conditions below 3.0 ft- were more dense, and contained more sit' content grading into weathered Glacial Till. This location resulted in less favorable infiltration rates ( less than 4 inches per hour 3.0 ft.) An Infiltration Facility could b designed to utilize the upper Soils Use a Design Rate = 2 " per Hr.for any F2cihty designed to o0erate in Lot 2 .................... ................................................ Lot # 3 pit anditest: The pit on Lot # 3 encountered clean sands and gr-avel-s in the upper 4 ft. However ( as with Lot #2 z�it` dense, Silty Soils were encountered below 4 ft. Jepth. The upper -soils did . I infiltrate at actual rates exCeeciing 8 inches perhour. Soils below 4-ft. clepths infiltrated much mmore % slowly. This location could support an infiltration fald1lity utilizing the well draining soils in the upper 4 ,--I ft. Use a Design Rate = 4 " per Hr. ............. I ............................................................................ .............................. Summary and Recommend tions: Three additional deep tes-, oits were dug. One Per lot. Geo�echnical evaluation verified subsurface conditions of each pit. Eazh pit did verify an effec—Live zone for infiltration. '_ I The City of Edmonds approved Small PIT test procedure was performed on each of the three soil pits, The Eastern pit (Lot # 1) performed optimally — with rapid actual infiltration —and no zones of impermeable material. Lot #2, and # 3 pits did verify functional infiltration rates —but only in the upper portions of the pits. Deeper soils were NOT conducive to infiltration. Upper portions of the soils ARE conducive to infiltration. Follow up (next day) excavation of the 3 test pit bottoms revealed No standing water in Pit 4 1. No standing water in pit # 3. However, some water was evident in the base of Pit # 2 This Engineer prefers the practice of constructing one infiltration facility per lot. However, this overall site avails limited upper soils for infiltration at the western portion, and excellent soils for infiltration at the eastern portion. This addendum report satisfies the Review comments from City of Edmonds August 8, 2017 Thus, the optimum geotechnical solution would be the following: Install ALL downspouts from ALL 3 housect into a tightline that discharges into the existing city of Edmonds stormwater systern in Pine St. and/or 9"' Ave. Inspections: Geotechnical Inspections to verify the following: Soil subgrade conditions at the specific location of the Infiltration Facility ( Drywell, Trench). Actual construction of the Facifty (materials, installation, filter fabric, pipe connections, etc). 07 of WAS, Dennis M. Bruce, P.E. kc jk Geotechnical Civil Engineer < r PVC FOC nm!GP-A:.t-- fN qu� - cl lob NV N .10 _AW I 'Al J �E T i-Y, 9� P't a _F-L 4A.- -11 "t -OP Cf :Ap -01 X -001 - TI.- CW5 tf*' IL C ER 6 iT SD b"&V. pvc mmm Q%m pvc r. OtA. Ax, LCT 1 0, wv%v 30"cu-, Fk%t!L.Y--/ INC .07 1-1, o,,= rAmiL r 0. Ir 7 OF Qj't .40 os IV 4va vc EX C SLOP-- EASEWNT jxn= ra m ELM 't 4 vE EC m0g.'2344-76 m i I EU­ %Q i.) 'A � - -V 75 ' Vf� P A A 11 gz JI'T �la- ---1 Xi T :7- ;z-AiPWNDS DrVL, OPMEN7 LLC LNR r--7 w �17ytl- JUNE 2017, bw EDMONDS STORMWATER ADDENDUM LW A p p e, n d x 0 c' cz Ign Pr D e t e r rn' ming Design frifiEtration Rates r 'r? jUNI 2017 APPENDIX B - METHODS FOR DETERMINING DESIGN INFILTRATION RATES If). Within 24 hours aftcr the conclusion of testing. mt. r-cxcaN ate the pit to .1�ee if the test water is mounded on shal lom, restrictive layers or if it _hw continued to flow deep into the subsurface. The depth of excavation varies depending on soil t-vl)c and depth Io hydraulic restricting layer. and 15 determined by the engineer or certified soils ptofes�,ional. Moun d-ing is an indication that a mounding analysis is nccc,;s-,irN. Data Analysis: I. Calculate ard record the infiltration rate in inches rer hour in 30 minutt—, or I -hour increments until I hour after file flow has stabilized, Nate: Lse si�atistical trend analysis to obtain the houriv flow rate when the flow stabillLe.s. This would be the lowest hourb, flmk rate. 2. To compute the design Infiltration rate (Ksatd,,). apply appropriate correction factors outlined previousiv. Example: *I'he area of the bottom of the test pit is 8.5 feel by 11.5 feei, Water flow rate was measured and recorded at inten-als ranging from 15 to '30 minutes throughout the lest. Between 400 minutes and 1 .000 minutes, the I'low rate stabilized between 10 and 12..5 gallons per minute or 600 to 750 gallons per hour, or an a% erave off 9.,4 — 12.3) 1 � I I I inches per hour. ro compute the design infiltration rate (Ksat&,,,,.), the infiltration rate must then be aqjusted by the appropriate correction factors outlined previouslN. B. 3.2 Small -Scale Pilot Infiltration Test A ,mallcr-scalc PI -I can be UScd in any ofthe following Instances- • The drainage area to the infiltration site is le,�:� than I acre. • The testing I-, for bioretention area:� or permeable pavement surfaces that either serve small drainage are -is and (it- are xvidel-%, dispersed throughout a project site. • The ,lie has a hial, int-41ttaiion rate. making I , a large- scale PfT diffiLcuk. and the site geotechnical ly in'�eS62_atiOn Uniform Alb'.Airfacc chatactensties. Infiltration Test: i Fxcdk ate thc test pit to tht estimate �d_k2upi of the ?ropozed infiltrat,ort titcdity. fit the case ot, 'T%-- le estimat vat i on at 7�i_c �Ihe I j�inported ��;oi I TnI_X%A I I I I le oil I up Lit hioretelition. exca. a . to ed cle � the underlying name soil. I or permeable PaVement. excavate it) the elevation at %Nhich the imported subgradc materials. or the pavement itsell. m. III contact the Linderking iiative still. Ifib,: native soils troad ,,ubgradv) will have to meet a mitilinurn subgrade compaction rquireineriL. compact file nati\c soil to that requirement pnor io testing. \ote that Ibe pmneable paNernerit de,zign guidance recommends compaction not exceed 90 to 92 percent. Finally. ]a) back tbc slopes suffi(_ientf� to I\ oid cak inp stdc� ofthe test pit. and eioblon dui nu the test. Mternawciv. conbidef shorjn� the j-3 METIJOD I FIELD TESTING PROCEDURP3 7 APPENDIX B - METHODS FOR DETERMINING DESIGN INFILTRATION RATES JUNE 201-1 2. The horizontal surface area of the bottom of the test pit should be 12 to 32 square flect. it may be circular or rectangular, but accurately document the size and Lyea-metty of the test pit. 3. Insiall a-y-grtical measurim-, -od adequate It) measure t' he ponded water depth and that is marke(I in half-incfi7m'crements in the c'enter of the pit botjop-,� J 4. Use a i0_';b_2Late on the bottom to convey water to thQ pit and reduce side wall erosion or excessive disturbance of the pond bottom. Excessive erosion and bottom disturbanc,� will result in clogging of the infiltration receptor and yield lower than actua'! infiltration rates. Use a ' )-inch-diameleT pipe lor pits on the 3,111alker end of the recommended -,urface area, and a 4-�nch pipe for pits on the larger erd of the recommended surface area. 5. Pre-suak period: Add water to ihe pit so that there is standing water fot at least 6 hours. Maintain t e :r Pic 6A water level at 11cast 12 inches abo,,c the bottom of the pit. 6. At the end of the pre-soak pt;iiod, add water to the pit at a rate that %kill mairtain a fixed water level between 6 and 12 inch--s abok,c the borom of t'ie pit ove r a full hour. The depth must not exceed the proposed maximum depti-, of water c-<pcctcd in the completed fincilit-,. 7. Every 15 minutcs. record the cumulative volume and instantaneous flow ratc in gallons per let minute necessary �o �maintain__& water level at the same point (between 6 to 12 inches) on the neasuring rod. �hc specific depth should ba the same as the maxinnurn dc-igned panding depth (,usually 6 to 12 inches). 4�AEfftter I �Ihiour turn off the %A a1!5 and record the rate of intdltration (the drop nve of the standing watErTi—nin-c-hes-rer �botjr from the meauxing r_o_a7d__a�a_,_u_n_tiT the pit is empq, 9� A self-loq i - gin-o pressure sensor may also be used to determine water depth and drain -down. 10� 'Within 24 hours after the conclusion of testing..2N�er-excavate the pit to see if the test water i�, ricti� e lavers or if ", baT�oatinued to 1`15-A-7e—ep intc, the-Tub-s-u—Race- The mourded on shallow rest depth of excavation vade� depending on soi I type and depth to hydraulic restricting laver. and ik determined by the engineer )r certified soils professional. The soils professional shouldjudge Lif whether a moundinu analysis is necessary. — --------------------- Data Analysis: Use the -guidance for the larp-�cale I'l-I'method outlincd !ibovt. B-3.3 Failing Head Percolation Test Procedure (as modified for the City of Edmonds) (Source: U.S. EPA, On -site Wastewater Treatment and Disposal Systems, 1980) \ole This test MLIVonly be itsed for pet�ortnance veriiicarion testinc, as ontlined /-eviwishl in this C, llpz)�Wdi_r Thivtesl niaY nothe used.16r BAIP devign o), t,) dumonsti-ate infeasibilih- of"Ineeting1fliumim? Requirenieni No, 5. 1, Location of Tests Tcsts shall bc spaced unifoi.i,ly throughout th�.,. arca. 11'soil co-ndiiions are high1v variable. mor,.� be S-3 10F.T IC)D i -FIFLD PROC�DURFS: 0 921 Pine St. Additional test pits and infiltration Testing. Lot # 3 Sands, with gravels in upper 4 ft. allow for infiltration facility witt) a Design Rate = 4 inchej_per "q�Lr Note rapid actual infiltration in Lot # 3 PIT test. V a Lot 4 2 Test Pit encountered upper sands top 3 ft.) capable of infiltration. However, soils below 3 ft. were weathered Glacial Till ( above) whjich precludes deeper infiltration- w IL qa",., W",:" Slow actual infiltration (4 - / Hr.) in upper portion of Test pit, but little, if any infiltration below 3 ft. depth in Lot #2 Ac 4 jEF"lk & r -qW Example of "chunk" of weathered Glacial Tili below 3 ft. depth. Effectively, no infiltration below 3 ' at this location Lot# 1 Test Pit at East portion of overall property. Lot # 2 pit DOES contain sands /gravels ABOVE 3 ft. depth ,-ot # 3 pit verifies san&/Igravel�s above 4 ft. depths Rapid actual infiltration (exceeds 16" per hour) Lot # I Consistent sands I gravels tc, pit bottom 921 Pine St. Lot # I Test Pit verifies sdnds wl gravels. PIT test verifies good infiltration rates East property line fences at left U U-1 5 Rod to measure infiltration rates in Lot # I Test Pit. Actual rates exceeded 16 inches per hour Use Design Rate = 8 r)er Hr. for Infiltration Facilities in Lot #1, V �,N7 -! j5" ,-7 C Willi bow Auiewku,& co 'V W Dennis M. Bruce, P.E. 96 RO(7 M's C F, RRA. --= -, - - Z— — , Geotecinical !Civil -ffn-ginepr 0 Addeqd ine St. 4m___!j21 Pi ___fair pro.e Ct City of Edmonds # PLN 20170033 This engineering report pFesents the results of additional geotechmcal EvFluation (more Test Pits. Small P!T Infiltration Testing) at 921 Pine St. This additional tEstincy was required by City of Edmonds Review Comments pertamingto the proposed development of 3 new,--.F S R, Additional Soil Test Pits: See Site Plan depicting the proposed 3 lots and the additional test pits dug October 10, 2017. One test pit was dug per lot (per layout on the Site -'Ian). Each p!t was dug to ft. depth. Subsurface conditions are preiented on thef'ollowing Soil Logs: )/P -1 e2st Pit Lot 1 ( 1--ast Portion of overall property): 0 _8 r, Lawn, roots, organic �,ilt. 8 " to 0 ft- (bottom of pit) Coi,sisent Sands with Gravp�s. This entire zone is cornpatible with infiltration. est iltt L#)t 2 : 0 -8 ' Plant onts, organic sift, 8`-3.0ft. Sands with Gravek. This �!,)ne is compatible with infiltration. 3.0'—/o' increasingly silty sands grading into weathered Gladal TIM. This zone is NOT compatible with i.ifiltration.111P, - Test Pit L A 3: 0' -8 " Plant rocts, organirs, silt. 8" - 4 ft- Sandc 1vith Gravels rnis zonc is compatible with infiltration. 4 0. L�e�l"O ft incr cc singly silty sands grading ;nto weatht-red Glacial Till- This zone i!, NOT compatio e with infiltr3TIon. See oh,)tr., sheets of Test Pits anJ !nfiltration Testing q ol) C 0 ;-6,Jj1r)AT;C'.S I'.' UF 4 1 , 0 , " :, , - i ;if- * & F&Heyll 1 0 N�LiAL P -) 6ti; 551502 v A c)Rln 546 92- 3.5 TO-rTONA C;0.-A .... .................................................. ...... .0 Additional Infiltrat-lon Tes Ing, Three n '�'j ew test pits were dug to e. depths on October 10, 2017. Each Pit was filled to a minimum of 18 inch depth with water to establish the Pre -Soak condition per City of Edmonds approved Small PIT procedures (attached) Actual Testing began the following day (October 11. 2017) - performing the Small PIT test on each Te�t Pit .................... .. ......................................... ......... ............. ..................... _ .... . ..... ............... - The eastern it Lot 9 11 had verified sands with gravels for the entir4e. de.Vth of pit. The Infiltration Test verified this consistent condition: Actual Infiltration Rates exceeded 16 inches Per hour. This condition ( clear observable soils that are consistent throughout the entire pit) AND actual test results verifying excellent infiltration rates APPROVE this Lot # I zone for an Infiltration Facility *r (�S A-C Z� VSALY- K FT USE: A Desig:nRa:te �fc!ilitip in this area� tv-steW (MY It X. 0 X ............ I.E .. ..... ......... .... ... - Lot#2pitandtest: The piton Lot #2 encountered clean sands and gravels in the upper 3.0ft. However, soil conditions below 3.0 ft. were more dense, and contained more silt content grading into weathered Glacial Till. This location resulted in less favorable infiltration rates ( less than 4 inches par hour Q LY in the soil zone abo e 3.0 ft.) An Infiltration Facility i;ould b designed to utilize the upoer I I�Ksoils/ Lfs_eE3De:sie:n Rat for @nV Facilitv designed to operate in Lot 2 IfIN X 0 if 0'sr X 0. Lot # 3 pit and test The pit on Lot 4 3 encountered clean sands and gravels n the upper 4 ft. However ( as with Lot N2 pit) der -se, silty soils were encountered below 4 ft. eepth The upper Wils 'lid infiltrate at actual rates exceeding 8 inches per hour !ioils below 4ft. depths infiltrated much more slowly. T is location could support an infiltration facility utilizing the well draining soils in the upper 4 Use a :Design Rate—/ A O.C1 �e. tf &.1 - -Ti:� \45 11 PT N T4'A IF 1-50tL _RZILOW Summary and Recommendations: 4 &)Oy IMMTMATS 5rlFIEC ?-I\JELY. Three additional deep test pits were dug. One per lot -Is Geotechnical evaluation verified subsurface conditions of each pit. Fach�pit d"id verify an effective zone for irfiltrarion 01JV:*:L0V) 71(s R41[81C. 61" GY-6T-'Fu'..' The City of Edmonds approved Small PIT test procedure was performed on each of the three soil pits. The Eastern pit (Lot # 1) performed optimally — with rapid actual infilt impermeable material ration —and no zones of Lot #2, and # 3 pits did verify functional infiltration rates —but only in the upper portions of the pits Deeper soils were NOT conducive to infiltration Uppe, portions of the soils ARE conducive to infiftratior.. Follow up (next day) excavation of the 3 test Pit bottoons revealed Nostanding water in Pit # I Nostanding water in Pit # 3 However, some water wes evident in the base of Pit 4 2 This Engineer prefers the practice of constructing one infiltration facility per lot, However, this overall site avails limited upper, soils for infiltration at the western portion, and excelient soils for infiltration at the eastern portion. - This addendum report satisfies the Review comments �rom City of Edmonds August 8, 2017 - Thus, the optimum geotechnical solution would be the following. Thu E ry Install ALL downspouts from ALL 3 housect into a tightline that discharges into the existing City of drn onds stormwater system in Pine St. and/or 9"' Ave Install an infiltration Facility on I ot # I -Lo handle sto-rrwater from all 3 of the new S.F.R. Inspections: Geotechnical Inspections are reguired to verify the following Soil subgrade conclWors at the specific location of the Infiltration Facility ( Drywell, Trench)- Actual construction of the Facility (materials installation, filter tabric, pipe connections, etc) Dennis M. Bruce, P.E. Geotechn cal / Civil Engineer T/4-1: 41 41, 1� J:�� Lo r,:C, fi'v -a At �PA nL(T 'SS �e' , 'U D77 7t. �Z'� U S (A, T"rol t-v Cr -Ir L� t Q '5' _0 Lo -r I Client I - " r -' I I 1011 Q& 10A Fairwinds Development, LLC Steve Nielson 13110 NE 177th PL, Suite 194 Woodinville, WA 98072 425.998.9809 phone fax I Ft,6�� * �A �S7 SSS#1 s1811020 N' SA"L 10/ Project 917 Pine Street Identification 2 Story SFR Novion Group Inc (206-361-6133) WAC 196-23-070 Section Engineering Calculations 1 Design Criteria 2 Wind & Earthquake Design 3 Framing Analysis 4 Foundation Design 5 Detail Calculations ,,I 7"1F;y L —2v FEB 2 1 2019 24113 56th Ave W - Mountlake Terrace, WA 98043 - Ph: 425-778-1023 - Fax: 206-260-7490 Su> ao \at '- 0 t % 41 *-"' r EV OR; ll 101.1 DESIGN CRITERIA 10 6628 212th Street SW, Suite 205 - Lynnwood, WA 98036 - Ph: 425-778-1023 - Fax: 206-260-7490 I DESIGN CRITERIA Governing Code 15 SBC Risk Category II Wind Design Data I Basic Wind Speed (3 sec gust) mph 110 Surface Roughness B Wind Exposure Category B Internal Pressure Coefficient 0.18 Topographic Factor, K, 1.00 Wind Importance Factor, 1 1.00 I Earthquake Design Data I Seismic Importance Factor, 1, 1.00 Site Classification D Short Period Acceleration, S, 1.267 I -Second Acceleration, S, 0.496 Seismic Design Category D Spectral Response Coefficient, SDS 0.845 Spectral Response Coefficient, SW 0.497 I Gravity Load Data IRoofs: loads are psf Deaa-- Live Snow Seismic Force Resisting System able 12.2-1: A-15 Response Modification Factor, R 6.5 6.5 Transverse Longitudinal 2010 Equiv. Lateral Force Procedure Seismic Response Coefficient, Cs 0.130 0.130 Transverse Longitudini I Iseismic Base Shear, v 20475 lbs Trusses (flat) *Occupiable 2 Top Chord 4 15 60 25 Bottom Chord 5 0 0 -Solar-Ready 3 Top Chord 4 15 0 25 Bottom Chord 5 0 0 Floors: loads are psf Dead Live Snow 3oists5 15 40 0 Trusses Top Chord 8 40 0 Bottom Chord 4 0 0 Decks: loads are psf Dead Live Snow Joists'5 20 60 25 Trusses Top Chord 15 60 25 Bottom Chord 5 0 0 Notes apply as called out in table above. 2 Roof has direct access and is intended to be used by occupants as living space. 3 Dead load includes 5psf for photovoltaic panels. 4 Slope top chords to drain; see architectural plans. Is Joists of sawn lumber or wood I -joists. � Soil Data jAllowable Soil Bearing 1200-0--P-s-f] 12/3/2018 Design Maps Summary Report W,= Design Maps Summary Report ilm User -Specified Input Report Title 917 Pine St Mon December 3, 2018 20:35:58 UTC Building Code Reference Document ASCE 7-10 Standard (which utilizes USGS hazard data available in 2008) Site Coordinates 47.803470N, 122.36638OW Site Soil Classification Site Class D — "Stiff Soil" Risk Category I/II/III C0 A., RO 0 qT P�)RT 6 A k,18-f RESERVAID'ON Lynnwqod Edirriond?t Mountlake Terrac Bothell jndanola "Sh orefine 3 'Suquamish V Ft R 0,R7 USGS-Provided Output S, = 1.267 g S,, = 1.267 g. S,, = 0.844 g S, = 0.496 g S,, = 0. 746 g So, = 0.497 g For information on how the SS and S1 values above have been calculated from probabilistic (risk -targeted) and deterministic ground motions in the direction of maximum horizontal response, please return to the application and select the "2009 NEHRP" building code reference document. AIC Ett Response Spectrum, IA1 4 PeritA, T 45m) 06 Design ResponseSpectrum Perind, T um) For PGA,, T, C,S' and CRI values, please view the detailed report. Although this information is a product of the U.S. Geological Survey, we provide no warranty, expressed or implied, as to the accuracy of the data contained therein. This tool is not a substitute for technical subject -matter knowledge. hftps:llprod02-earthquake.cr.usgs.gov/des�gnmaps/us/summary.php?template=minimal&latitude=47.8034732&longitude=-122.3663753&siteclass=3&r 2600l+ 15QL tAILS I':', ...... .. .. 00 ;t 3�0 Pine St !4 :jv- GoogleEarth At* 1 3000 ft Topographic Effects Distances below are measured from the base. Crest elev: 380 dist: 6811 Site elev: 338 dist: 5544 H/2 elev: 190— dist: 3940 �2D 9,10(5�6 Base elev: 0 dist: 0 Exposure Category B Height above local ground Z= 27 ft Location Relative to Crest Upwind Hill Shape 2-D Rd1g Height of Hill H= 380 ft Distance upwind of the crest to where the Lh= 2871 ft difference in ground elevation is half of the height of the hill. x= 1267 ft Distance upwind (or downwind�) from the crest to Wind Speed-up over Hills, Ridges, and Escarpments 1) The hill, ridge, or escarpment is isolated and unobstructed upwind by other similar topographic features of comparable height for 100 times the Controlled height of the topographic feature or 2 mi., whichever is less. This by: distance shall be measured hohzontally from the point at which the height H of the hill, ridge, or escarpment is determined. 2) The hill, ridge, or escarpment protrudes above the height of upwind terrain features within a 2-mi radius in any quadrant by a factor of two or more. 3) The structure is located as shown in Fig. 6-4 in the upper one-half of a hill or ridge or near the crest of an escarpment. 4) H/Lh >= 0.2 H/Lh >= 5) H is greater than or equal to 15 ft for Exposure C and D and 60 ft for H Exposure B Topographic factor If site conditions and locations of structures do not meet all the conditions specified in Section 26.8.1 then Kzt = 1.0. Otherwise: K,t= 1.25 Ki= 0.17 K2= 0.71 K3= 0.97 Case Studies in Kzt Determination 2-mi True 2-mi True True 0.13 False 380 True K,t= 1.00 Nk TV - IN WO 10 I.ATERAL ANALYSIS rl 6628 212th Street SW, Suite 205 - Lynnwood, WA 98036 - Ph: 425-778-1023 - Fax: 206-260-7490 Lateral Analvsis s1811020 Number of Diaphragms Code General Design Criteria 2 15 SBC 2015 Seattle Building code & 2010 ASCE7 Design Loads (r)sf) Dead Live Snow Seismic Mass Roof 1 15 --- 25 15 Rf Deck 2 20 60 25 20 Floor 2 15 40 --- 15 Wall 1 10 10 Wall 3 15 15 Species of Framing Lumber Shearwall Stud Spacing Risk Category Wind Design Criteria Wind Load Design Procedure Basic Wind Speed Surface Roughness Wind Exposure Category Topographic Factor Enclosure Classification Internal Pressure Coefficient Seismic Design Data Seismic Load Desicin Procedure Seismic Design Category Mapped Spectral Accelerations, MSA Short Period Acceleration 1-Second Accelleration Long -Period Transition Period Spectral response coefficient Spectral response coefficient Site Classification Seis. Force Resisting System Response Modification Factor F Seismic Response Coefficient C Design Base Shear Overstrength Factor HF 16" oc II 2010 Directional Procedure 110 mph B B Kzt .1.00 Enclosed Building +/- 0.18 2010 Equiv. Lateral Force Procedure D Ss 1.267 S, 0.496 TL 6 sec. SDS 0.845 SDI 0.497 D Table 12.2-1: A-15 Transverse Longitudinal 6.5 6.5 S 0.130 0.130 20475 20524 lbs Q,, 2.5 _SSSIateral—s'1811020 DC Pq b.W loud Wind Loads Ridge Elevation 23.5 ft Eave Height 20.25 ft Mean Roof Height, h 21.875 ft Least Horizontal Dimension, LHD 34.75 ft Transverse Direction B Dimension 34.75 ft L Dimension 88 ft End Zone, 2a 6.95 ft Transverse Direction (WW) Roof Pitch Classified: Angle 0 :12 Enclosed Building 0 LEVEL Wall Area Roof Area (Horiz Proj) (sq ft) N2 199 sq ft 01 qft , 3531sq ft 01sq ft Transverse Direction (LW) Roof Pitch Classified: Angle 0 :12 Enclosed Building 0 LEVEL Wall Area Roof Area (Horiz Proj) (sq ft) 2 199 sq ft 01 q ft 1 384 sq ft 01sq ft Wind Loads Help XPEL WL XPELBD Longitudinal Direction (WW) B Dimension 88 ft L Dimension 34.75 ft ,End Zone, 2a 6.95 ft Longitudinal Direction (WW) Roof Pitch Classified: Angle 0 :12 Enclosed Building 0 LEVEL Wall Area Roof Area (Horiz Proj) (sq ft) 2 555 sq ft I , 10481sq ft Isq ft Longitudinal Direction (LW) Roof Pitch Classified: Angle 0 :12 Enclosed Building 0 LEVEL I Wall Area Roof Area (Horiz Proj) (sq ft) 2 1 5551sq ft 0 sq ft 1 1 10481sq ft 0 s Nqft Wind Variables XPELVIIV Basic Wind Speed, V 110 mph Topographic Factor,Kzt 1.00 Directionality Factor, Kd 0.85 Velocity Pres. Exp. Coeff. Kz 0.62 Gust Effect Factor, Gf 0.85 Velocity Pressure, gh 16.37 psf Main Wind Force Resisting System - Diag)hragm Design Loads XPEMWF 2010 Directional Procedure Direction Transverse Longitudinal sum 10050 25648 Load Case 1 L L-16psf 2 3599 8880 1 6452 16768 _SSSIateral—s'1811020 WF(2) Seismic Loads Yes C" 6; .1 ; ; kf �f Qf­ IvI XPELSL YPFFSW Diaphragm height (ft) 1 (Ibs) 2 Roof 2 Rf Deck 2 Mass (lbs) area (e) 3050 450 70000 trans - wx 74725 long - w., 79675 Walls height (ft) 9 trans -wall (ft) <--) unit weight (psf) 10 15 long -wall (ft) Wall 1 Wall 2 Mass (Ibs) 105 9450 unit weight (psf) 10 10 Wall 1 200 Wall 3 10 mass (Ibs) 19350 Diaphragm height (ft) I (lbs) 1 Floor 2 Rf Deck 2 Mass (Ibs) area (ff 2256 616 46160 trans - wx 82835 long - wx 78264 Walls height (ft) 9 trans -wall (M <—) unit weight (psf) 10 15 1 long -wall (ft) Wall 1 Wall 2 Mass (Ibs) 280 25200 unit weight (ps� 10 10 Wall 1 250 Wall 3 25.612 Mass (lbs) 25958 trans - w, long - w, ISum of Effective Seismic Weights (lbs) 196118 196118 1 _SSSIateral—s'1811020 EF Mapped Spectral Accelerations XPEMSA. Ss 1.267 Fa 1.000 SDS 0.84 S, 0.496 Fv 1.504 SDI 0.50 OR Seismic Design Category D Seismic Importance Factor 1 1.00 imw Seismic Use Group Site Classification D 2010 Equiv. Lateral Force Procedure XPEELF . Transverse Longitudinal 6w Approximate Period Ct 0.020 0.020 Parameters X= 0.75 0.75 Approximate Fundamental Period T= 0.189 sec 0.189 sec hn= 20.0 ft TL = 6 sec: Transverse Longitudinal CS = 0.130 0.130 lbs EQ 12.8-2 OR (Maximum) C�; = 0.405 0.405 lbs EQ 12.8-3 / 8.4 I' (Minimum) Cs = 0.037 0.037 lbs EQ 12.8-5 ON (Minimum) Cs = 0.010 0.010 lbs EQ 12.8-5 (Minimum) Cs = 0.010 0.010 lbs; EQ 12.8-6 Calculation of Seismic Response Coefficient XPESRC ResDonse Modification Coefficient and Seismic ReSDonse Coefficient a No Diaph. Trans Cs Mass V Long Cs Mass 2 6.5 1 0.130 74725 1 9710 6.5 0.130 79675 1 6.5 0.130 82835 10764 6.5 0.130 78264 Transverse Base Shear, h, V 20475 lbs Vertical Distributionof Seismic Forces k= 1.00 Longitudinal V 20524 lbs, XPEVDS Transverse Longitudinal Diaph. hx WX k wXhX CVX WX w),hx' CVX 2 20 84400 1688000 0.662 84400 1688000 0.662] —1 10 86139 861388.1 0.338 86139 861388.1 0.338 2549388 2549388 Diaphragm 2 Transverse 13557 lbs 6918 lbs SUM- 20475 Longitudinal 13589 lbs 6935 lbs sum 20524 P" —SSSIateral—s1811O2O EF two Allowable Stress Design Loads 2010 Directional Procedure Wind Load Combination 0.61) + 0.6W + H % of DL used in OT 60% Wind Design Loads F,, Transverse Longitudinal Diaphragm Force (lbs) Force (lbs) 2 2159 5328 1 1 3871 i 0061 2010 Equiv. Lateral Force Procedure Seismic Load Combination (0.6 - 0.14SOs)D + 0.7pQE + H % of DL used in OT 48% Seismic Design Loads, F), p 1.30 Transverse I 1.30 Longitudinal Diaphragm Force(lbs) Force (lbs) 2 12337 12366 1 6295 6311 Principle of Mechanics - cont. Where, v shear per linear foot of shearwall w width of shearwall h height of shearwall D resisting dead load centered over shearwall P resisting dead load at end of shearwall Shearwall calculations follow, where, V), VD., VT,,,, VT), L. V VF Max Tx V, w h dr d,a dr dfz, Tw..1 TWX Tex+1 Te), r% 1214.2 (V X 6) Total force in the diaphragm above story (x), pounds (lbs) Percent of Vx tributary to the shearwalls (SW) in the wall line Force from the diaphragm above that transfers to the SW's, lbs Force from the SW's above that transfers to the SW's, lbs IN MOMDM Total force in the SW's (VDx + VT,+,), lbs Total length of SW's (I w), feet (ft) Linear force in the SW's (VTx/L), pounds per foot (plf) Greater of v induced by wind or earthquake, plf Maximum uplift force of the SW's, lbs Free Body Diagram of a ShearWall Greater of v in the sheathing induced by wind per 2306.4.1 or earthquake per 2305.3.4, plf Width of SW, ft Height of SW, ft Tributary distance of roof (used to calculate D) along the width of the SW, ft Tributary distance of roof (used to calculate P) adjacent to the width of the SW, ft Tributary distance of floor (used to calculate D) along the width of the SW, ft Tributary distance of floor (used to calculate P) adjacent to the width of the SW, ft Wind uplift force of the SW above that transfers to the SW, IN Wind uplift force of the SW, IN Earthquake uplift force of the SW above that transfers to the SW, lbs Earthquake uplift force of the SW, IN _SSSIateral—s'1811020 DL Wall Line Story (x) Direction I Sheathing Shear SW Dimensions Tributary Dead Loads Wind Uplift Earthquake Uplift 2 Trans v, w h dr dra df df�, Twx,i Twx Tex�j Tex WIND E-QUAKE 104 11.63 9 -219 556 104 6.50 9 1 -12 1 723 VTx 507 1881 v 28 104 Max Tx 723 L VF V, 18.13 104 104 Wall Line Story (x) Direction Sheathing Shear SW Dimensions Tributary Dead Loads Wind Uplift Earthquake Uplift 2 2 Trans vs w h dr dra df dfa Twx,j Twx Tex,j Tex WIND E-QUAKE 337 6.75 9 580 2818 VTx 640 2278 v 95 337 Max Tx 580 2818 L VF V� 1 6.75 337 337 Wall Line Story (x) Direction I Sheathing Shear SW Dimensions Tributary Dead Loads Wind Uplift Earthquake Uplift 3 2 Trans v,, w h d, dra df dfa Twx+l Twx Tex,, Tex WIND E-QUAKE 116 5.75 9.5 78 905 116 5.50 9.5 89 913 116 7.33 9.5 11 850 VTx 748 2542 v 34 116 Max T, 182 988 165 3.33 9.5 182 988 L V, V, 1 21.92 116 165 Wall Line Story (x) Direction I Sheathing Shear SW Dimensions Tributary Dead Loads Wind Uplift Earthquake Uplift 4 2 Trans V, w h dr dra df dfa Twx+j Twx Tex-,, Tex WIND E-QUAKE 93 19.75 9 -633 195 112 1 3.75 9 15 715 1 105 4.00 9 5 707 VTX 615 3093 v 19 93 Max Tx 15 715 93 5.75 9 -66 650 L VF vs 33.25 93 112 Im —SSS[ateral—sl 811020 FIR -.9 Wall Line Story (x) Direction I Sheathing Shear SW Dimensions Tributary Dead Loads Wind Uplift Earthquake Uplift 5 2 Trans v , w In dr dra of dfa Twxj Twx Tex,, Tex WIND E-QUAKE 275 6.50 9.25 345 2325 462 2.75 9.25 501 2451 VTx 615 2542 v 67 275 Max T, 501 2451 L VF v S 9.25 275 462 —SSSIateral—sl 811020 FIR Wall Line Story (x) Direction Sheathing Shear SW Dimensions Tributary Dead Loads Wind Uplift Earthquake Uplift Trans v, w In dr dra of dfa Twx,j Twx Tex,, Tex WIND E-QUAKE 126 10.50 9.25 -26 723 1537 126 7.33 9.25 106 723 1643 126 6.25 10.75 175 723 1834 VT, 2225 6308 v 44 126 Max Tx 175 1834 126 26.00 10.75 -780 723 1067 L VF v 50.08 126 126 Wall Line Story (x) Direction I Sheathing Shear SW Dimensions Tributary Dead Loads Wind Uplift Earthquake Uplift 2 1 1 Trans v, w In dr or, df dfa Tw.,, Twx Tex,, Tex WIND E-QUAKE 584 7.50 10.25 580 3394 2818 8523 VTx 2312 4378 308 584 Max Tx 3394 8523 L V F v 1 7.50 584 584 Wall Line Story (x) Direction I Sheathing Shear SW Dimensions Tributary Dead Loads Wind Uplift Earthquake Uplift 3 —TTrans vs w In dr dra of dfa Twx+j Tw, Tex,, Tex WIND E-QUAKE 548 6.33 10.25 182 2885 988 6374 VTx 1851 3473 v 292 548 Max Tx 2885 6374 L VF VS 1 6.33 548 548 Wall Line Story (x) Direction I Sheathing Shear SW Dimensions Tributary Dead Loads Wind Uplift Earthquake Uplift 4 1 1 Trans vs w In dr clm of dfa Twx,j Twx Tex,, Tex WIND E-QUAKE 121 19.75 10.25 15 -418 715 1229 146 3.75 9 15 283 715 1686 137 4.00 9 15 272 715 1678 VTx 1718 4473 v 47 121 Max Tx 283 1686 121 9.33 9 1 1 1 15 56 715 1505 L V F V, 36.83 121 146 M —SSS[ateral—sl 811020 Ow FIR Wall Line Story (x) Direction I Sheathing Shear SW Dimensions Tributary Dead Loads Wind Uplift Earthquake Uplift A 2 Long v, w h cl, dra df dfa Twx-,, Twx Tex,j Tex WIND E-QUAKE 347 4.50 9 1407 2976 VT, 794 1561 v 177 347 Max Tx 1407 2976 L vr V, 4.50 347 347 1 1 1 Wall Line Story (x) Direction I Sheathing Shear SW Dimensions Tributary Dead Loads Wind Uplift Earthquake Uplift B 2 Long vs w h dr dr. df df. Twx,j Twx Tex,-, Tex WIND E-QUAKE 341 9.75 9 832 2755 VTX 1329 3328 v 136 341 Max Tx 832 2755 L VF vs 9.75 341 341 Wall Line Story (x) Directicn I Sheathing Shear I SW Dimensions I Tributary Dead Loads Wind Uplift Earthquake Uplift C 2 Long v, w h dr d,a df clf, T-x,l Twx Tex,, Tex WIND E-QUAKE 305 12.50 9.25 587 2402 366 3.75 9 925 2622 VTx 1945 4954 v 120 305 Max Tx 925 2622 L VF V, 16.25 305 366 —SSSIateral—sl 811020 FIR M r Fa MO PO No Pq fw..I SW Dimensions Eadquake Uplift WIND E-QUAKE VT, 1260 2523 v 53 105 Max Tx 166 L V, V, 24.00 105 105 —SSS[ateral—s 1811020 FR ==MR ffl'�_ SW Dimensions Earthquake Uplift —WIND &QUAKE VT, 2346 2704 v 361 416 Max Tx 4807 6999 L v, V� 6.50 416 416 Wall Line Story X Direction Sheathing Shear SW Dimensions Tributary Dead Loads Wind Uplift Earthquake Uplift B 1 Long V, w In dr dra clf dfa Twx+l Twx Te,,,, Tex WIND E-QUAKE 284 6.50 9 832 2503 2755 5097 284 1 7.75 9 832 2453 2755 5056 319 4.00 9 832 2605 2755 5178 VTx 3924 5176 v 215 284 Max T, 2605 5178 L V F v 18.25 284 319 LEI I I I I Wall Line Story (x) Direction Sheathing Shear SW Dimensions Tributary Dead Loads Wind Uplift Earthquake Uplift C Long V, w In dr dra df dfa Twx+l Tw), Tex,, Tex WIND E-QUAKE 303 16.75 9 925 2017 2622 4805 364 3.75 9 925 2544 2622 5228 VTx 4032 6214 v 197 303 Max T, 2544 5228 1 1 1 L VF v 20.50 303 364 Wall Line Story (x) Direction I Sheathing Shear SW Dimensions Tributary Dead Loads Wind Uplift Earthquake Uplift D 1 Long v, w In dr dra of dfa Tw,j Twx Te,,,, Tex WIND &QUAKE 92 16.50 10.75 579 162 VTx 2114 1233 v 128 75 Max Tx 579 162 L V F v 1 16.50 128 92 _SSSIateral—s1811020 FR am mm bw ON Wall Line Story (x) Direction I Sheathing Shear SW Dimensions Tributary Dead Loads Wind Uplift Earthquake Uplift E 1 1 Long v, w In dr dra df df�, Twx,.r Twx Tex,, Tex WIND E-QUAKE 140 24.00 11.75 186 166 787 VTX 2973 3350 v 124 140 Max T, 186 787 L VF V. 24.00 140 140 _SSSIateral—s1811020 FIR Shear Transfer Connections XPSTC Fasteners and Spacing 0 :2 V1 (n 0 (n 0 Ln LA :L' V M 1- C� 06 a a Ln N 0 M Ln a Ln ON 00 ko rq CL V, %0 Ln V- r4 ID M 2x Plates 3x Plates Ln Ln x x x x M M < CL X: 0 r4 r14 M 0 Zi C _J 0 on ES < M 21 < Co < cc, < 0 0 W CL 0 W CL 0 CL 0 CL 0 M -0 -0 E E E 05 E rN 00 r'J 0. 00 0- LU — Ln Ln 0i A ISO 11 9 48 46 10 33 16 101 75 110 B 350 4 20 19 4 14 7 29 32 47 C 450 3 16 15 3 11 5 21 25 36 D 600 2 1 12 11 2 8 4 15 IS 27 E 780 2 9 8 2 6 3 11 14 21 17 Shearwall Capacities from SDPWS-2015 Table 4.3A 2 = L. MINIMUM Tabulated Adjusted m m NOMINAL PANEL Nail or Staple size value for HF @ THICKNESS based on 16" oc (inch) DF 6 242 7/16" 8d @ 6"oc 260 242 4 1 353 7/16" 8d @ 4"oc 380 353 3 456 7/16" 8d @ Yoc 490 456 2 595 7/16" 8d @ 2"oc 640 595 44 707 7/16" BOTH SIDES 8d @ 4"oc 760 707 1. The above allowable capacities were reduced by 2 for ASD and are for Seismic loads. 2. Shears are Allowable Wind loads are 1.4 greater. This office permitted to be increased 3. G=0.43 [1- decreases the wind sheathing shear, v s, to values (0.5-0,43)] demand by this factor rather than using the shown for 0.0,3 increased capacity. That way, only one set of 15/32-inch ,capacities is needed for simplicity. sheathing 1001 um Px P" No an fmw No too PW PM FR WW 11" WW —SSSlateral—s1811020 ST V" 11M bud Shear Transfer Notes IiA (1] TABLE 12N (pg109 NDS] Z=89 lbs for a 16d box nail (D=0.135) in Hem -Fir G=0.43 and mow multiplied by the load duration factor TABLE 11.3.1 [pg66 NDS] for wind/earthquake which is CD=1.6 found in TABLE 2.3.2 [pg11 NDS] [2] Value from note I then multiplied by the Toe -Nail Factor SECTION 11.5.4 [pg88 NDS] % IN for nominal lateral design values Ctn=0.83 MW [3] the A35 is used in loading condition 4 in an F1 direction of load according to Simpson designations for SPF/HF Lateral(133/160) Z=450 lbs [pg331 C-C-2017] !l1w [4] 1 MW : [5] for SP5F/HF Lateral(133/160) Z=130 lbs [pg315 C-C-2017] [6] the HI is used in an F1 loading according to Simpson designations for SPF/HF Lateral (133/160) Z=415 lbs [pg315 C-C-2017] I IN [7] the DTC is used in an F2 loading according to Simpson designations for SPF/HF I Mod Lateral(133/160) Z=210 lbs [pg269 C-C-2017] [8] TABLE 12E [pg97 NDS] Z=590 lbs for a 1/2" diameter bolt in 1-1/2" side member of Hem -Fir G=0.43 and multiplied by the load duration factor TABLE 11.3.1 [pg66 NDS] for wind/earthquake which is CD=1.6 found in TABLE 2.3.2 [pg11 NDS] Sill plates resisting a design load greater than 350 plf shall not be less than a 3-inch nominal member. Exception: With design load less than 600plf the sill plate is permitted to be a 2-inch nominal member if the sill plate is anchored by two times the number of bolts required by desian. [9] TABLE 12E [pg97 NDS] Z=860 lbs for a 5/8" diameter bolt in 1-1/2" side member of Hem -Fir G=0.43 and multiplied by the load duration factor TABLE 10.3.1 [pg58 NDS] for wind/earthquake which is CD=1.6 found in TABLE 2.3.2 [pg11 NDS] Sill plates resisting a design load greater than 350 plf shall not be less than a 3-inch nominal member. Exception: With design load less than 600plf the sill plate is permitted to be a 2-inch nominal member if the sill plate is anchored by two times the number of bolts requiredby [10] TABLE 12E [pg97 NDS] Z=730 lbs for a 1/2" diameter bolt in 2-1/2" side member of Hem -Fir G=0.43 and multiplied by the load duration factor TABLE 11.3.1 [pg66 NDS] for wind/earthquake which is CD=1.6 found in TABLE 2.3.2 [pgl I NDS] [11] TABLE 12E [pg97 NDS] Z=1140 lbs for a 5/8" diameter bolt in 2-1/2" side member of Hem -Fir G=0.43 and multiplied by the load duration factor TABLE 11.3.1 [pg66 NDS] for wind/earthquake which is CD=1.6 found in TABLE 2.3.2 [pgl I NDS] F� ea liA _SSSlateral_s1811020 ST Horizontal Diaphragm Calculations ANSI/AF&PA SDPWS-2008 Table 4.2C Unblocked DF Panel Thickness Nails Case 1 All other Roof Diaphragm 1 7/16" 8d 230 170 Floor Diaphragm 1 23/32" (19/32") , 10d 285 215 The minimum depth of horizontal diaphragm required to provide shear capacity for SEISMIC forces The minimum depth of horizontal diaphragm required to provide shear capacity for WIND forces XPHDC Unblocked HF Case 1 All other 213.9 158.1 265.05 .199.951 Line Story Wind Seismic Middle or end Roof or Floor Case Shear Stress (wind) Shear Stress (Seis) 1 2 507 1,881 E R All other 158.1 3.2 11.9 2 2 640 2,278 E R All other 158.1 4.0 14.4 3 2 748 2,542 E R All other 158.1 4.7 16.1 4 2 615 3,093 E R All other 158.1 3.9 19.6 5 2 615 2,542 E R All other 158.1 3.9 16.1 A 2 794 1,561 E R All other 158.1 5.0 9.9 B 2 1,329 3,328 E R All other 158.1 8.4 21.1 C 2 1,945 4,954 1 E R All other 158.1 12.3 31.3 E12 1 1,260 2,523 1 E R All other 158.1 8.0 16.0 1 1 1,103 1,885 E F All other 199.95 5.5 9.4 1 2 1 1,673 2,100 E F All other 199.95 8.4 10.5 1 3 1 1,103 931 E F All other 199.95 5.5 4.7 4 1 1,103 1,380 E F All other 199.95 5.5 6.9 All 1 1,552 1,142 E F All other 199.95 1 7.8 5.7 B 1 2,595 1,848 E F All other 199.95 13.0 9.2 C 1 2,087 1,260 E F All other 199.95 10.4 6.3 1 D 1 2,114 1,233 E F All other 199.95 10.6 ' 6.2 E 1 1,712 . 827 E F All other 199.95 8.6 4.1 1 -SSSIateral-sl 811020 w owl I=: aw w aw Ow iso M" Ow OR HD Shear Wall Summary -2 Width SW VF % Stressed V, % Stressed Notes 1 2 18.13 A 6 104 69% 104 43% 2 2 6.75 C 3 337 75% 337 74% 3 2 21.92 A 6 116 77% 165 68% 4 2 33.25 A 6 93 62% 112 46% 5 2 9.25 B 2 275 79% 462 78% A 2 4.50 C 3 347 77% 347 76% B 2 9,75 C 3 341 76% 341 75% C 2 16.25 B 3 305 87% 366 80% E 2 24.00 A 6 105 70% 105 43% 1 1 50.08 A 6 126 84% 126 52% 2 1 7.50 E 44 584 75% 584 83% 3 1 6.33 D 2 548 91% 548 92% 4 1 36.83 A 6 121 81% 146 60% A 1 6.50 C 3 416 92% 416 91% B 1 18.25 B 4 284 81% 319 90% C 1 20.50 B 3 303 87% 364 80% D 1 16.50 A 6 128 85% 92 38% E 1 24.00 A 93% 140 58% Gray Scaled . I Area I s draw attention to the fact that 80% demand (corresponding to a 125% capacity) , has been specified to address horizontal irregularities. XPIRR I W —SSSlateral—s1811020 SW .MW Holdown Summa!y Wind Wind Wind Seismic Seismic Seismic Capacity Capacity Capacity Capacity Capacity Capacity Uplift W Uplift E Holdown Midwall Corner Endwall Midwall Corner Endwall 1 2 0 723 2 2 580 2818 HTT5 (a) 3740 @ 3740 @ 3740 @ 3740 @ 3325 @ 3740 @ 15% 15% 15% 75% 85% 75% 3 2 182 988 4 2 15 715 5 2 501 2451 MSTC52 (a) 3645 @ 3645 @ 3645 @ 3645 @ 3645 @ 3645 @ 14% 14% 14% 67% 67% 67% A 2 1407 2976 MSTC52 (a) 3645 @ 3645 @ 3645 @ 3645 @ 3645 @ 3645 @ 39% 39% 39% 82% 82% 82% B 2 832 2755 MSTC52 (a) 3645 @ 3645 @ 3645 @ 3645 @ 3645 @ 3645 @ 1 23% 23% 23% 76% 76% 76% C 2 925 2622 MSTC52 (a) 3645 @ 3645 @ 3645 @ 3645 @ 3645 @ 3645 @ 25% 25% 25% 72% 72% 72% E 2 0 166 1 1 175 1834 STHD14 (a) 5150 @ 5150 @ 3200 @ 3695 @ 3695 @ 3200 @ 3% 3% 5% 50% 50% 57% 2 1 3394 8523 HDU11 (b) 11175 @ 11175 @ 11175 @ 11175 @ 11175 @ 11175 @ 30% 30% 30% 76% 76% 76% 3 1 2885 6374 HDU8 (b) 7870 @ 7870 @ DNA 7870 @ 7855 @ DNA 1 37% 1 37% 81% 810 4 1 283 1686 STHD14 (a) 5150 @ 5150 @ 3200 @ 3695 @ 3695 @ 3200 @ 5% 5% 9% 46% 46% 53% A 1 4807 6999 HDU8 (b) 7870 @ 7870 @ DNA 7870 @ 7855 @ DNA 61% 61% 89% 89% B 1 2605 5178 HDU8 (b) 7870 @ 7870 @ 6820 @ 7870 @ 7855 @ 6820 @ 33% 33% 38% 66% 66% 76% C 1 2544 5228 HDU8 (b) 7870 @ 7870 @ 6820 @ 7870 @ 7855 @ 6820 @ 32% 32% 37% 1 66% 67% 77% D 1 579 162 E 1 186 787 _SSSIateral—s18111020 Sw PON PIN . WO r, Ke A W- o - +J-4 - ---------- GRAVITY ANALYSIS 6628 212th Street SW, Suite 205 - Lynnwood, WA 98036 - Ph: 425-778-1023 - Fax: 206-260-7490 File= SAJoWsMs18 I 1\s181 1020 - 917 Pine Street4o 181203N2F_enerGalc trib 180131.ec( I M ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.17. Lic. # : KW-06006655 Licensee: SOUND STRUCTURAL SOLUTIONS Description : (2-1) CODE REFERENCES Calculations per NDS 2015, 1 BC 2015, CBC 2016, ASCE 7-10 Load Combination Set: IBC 2015 Material Properties Analysis Method: Allowable Stress Design Fb - Tension 900.0 psi E: Modulus of Elasticity Load Combination IBC 2015 Fb - Compr 900.0 psi Ebend-xx 1,600.0 ksi Fc - Prll 1,350.0 psi Eminbend - xx 580.0 ksi Wood Species Douglas Fir - Larch Fc - Perp 625.0 psi Wood Grade No.2 Fv 180.0 psi Ft 575.0 psi Density 31.20 pcf Beam Bracing Beam is Fully Braced against lateral -torsional buckling Q(0.02) S(O.025) 2x12 Span = 16.750 ft Applied Loads Service loads entered. Load Factors will be applied for calculations. Uniform Load : D = 0.020, S = 0.0250, Tdbutary Width 1.0 ft, (ROOF) DESIGN SUMMARY Maximurn Bending Stress Ratio 0.5711 1 Maximum Shear Stress Ratio 0.162 : 1 Section used for this span 2x12 Section used for this span 2x1 2 fb: Actual 598.53 psi fv : Actual 33.50 psi FB: Allowable 1,035.00psi Fv: Allowable 207.00 psi Load Combination +D+S Load Combination +D+S Location of maximum on span 8.375ft Location of maximum on span 0.000ft Span # where maximum occurs Span # 1 Span # where maximurn occurs Span # 1 Maximum Deflection Max Downward Transient Deflection 0.156 in Ratio= 1285 ­360 Max Upward Transient Deflection 0.000 in Ratio= 0 <360 Max Downward Total Deflection 0.282 in Ratio= 714 ­240. Max Upward Total Deflection 0.000 in Ratio= 0 <240.0 Overall Maximum Deflections Load Combination Span Max . ..... Defl Location in Span Load Combination Max. Defl Location in Span +D+S 1 0.2815 8.436 0.0000 0.000 Vertical Reactions Support notation Far left is #1 Values in KIPS Load Combination Support 1 Support 2 lGo Overall MAXimum 0.377 0.377 Overall MINimum 0.101 0.101 D Only 0.168 0.168 +D+S 0.377 0.377 +D+0.750S 0.325 0.325 +0.60D 0.101 0.101 S Only 0.209 0.209 0W Illff Wood Beam File= S:Uobs\s181s181l1ks1811I020-917 Pine Street\wo 181203\2F enercalctrib'180131 ed ENERCALC, INC. 1983-2017, Build:6.17.2.' 28, Ver:6.17.2.2 A Lic. #: KW-06006655 Licensee - SOUND STRUCTURAL S0LUW#, Description : (2-2) CODE REFERENCES Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10 Load Combination Set: IBC 2015 Material Properties Analysis Method: Allowable Stress Design Fb - Tension 900.0 psi E Modulus of Elasticity Load Combination IBC 2015 Fb - Compr 900.0 psi Ebend-xx 1,600.0 ksi Fc - PrIl 1,350.0 psi Eminbend - xx 580.0 ksi Wood Species Douglas Fir - Larch Fc; - Perp 625.0 psi Wood Grade No.2 Fv 180.0 psi Ft 575.0 psi Density 31.20 pcf Beam Bracing Beam is Fully Braced against lateral -torsional buckling 2x12 Span = 6.0 ft Aplalied Loads Uniform Load : D = 0.020, S = 0.0250, Tributary Width = 1.0 ft, (ROOF) P:)int Load: D = 0.1680, S = 0.210 k @ 2.0 ft, ((2-1)) DESIGN SUMMARY Maximurn Bending Stress Ratio Section used for this span fb : Actual FB: Allowable Load Combination Location of maximum on span Span # where maximum occurs Maximum Deflection Max Downward Transient Deflection Max Upward Transient Deflection Max Downward Total Deflection Max Upward Total Deflection Ovorall Maximum Deflections Load Combination Span _�D_4 S 1 Vertical Reactions Load Combination Overall MAXimum Overall MINimurn D Only +D+,13 +D+0.750S +0.60D S Only Service loads entered. Load Factors will be applied for calculations. O�259. 1 Maximum Shear Stress Ratio 0.166 : 1 2xl 2 Section used for this span 2x12 258.96 psi fv : Actual 34.40 psi 1,035.00 psi Fv: Allowable 207.00 psi +D+S Load Combination +D+S 2.015ft Location of maximum on span 0.000ft Span # 1 Span # where maximum occurs Span # 1 0.008 in Ratio= 9571 >=360 0.000 in Ratio= 0 <360 0.014 in Ratio = 5317 ­240. 0.000 in Ratio= 0 <240.0 Max. "-" Defi Location in Span Load Combination 0.0135 2.825 Support notation Far left is #1 Support 1 Support 2 0.387 0.261 0.103 0.070 0.172 0.116 0.387 0.261 0.333 0.225 0.103 0.070 0.215 0.145 Max. 'Y' Defi Location in Span 0.0000 0.000 Values in KIPS File= S:\Jobs\s18\s1811\s1811020 - 917 Pine Street�wo 181203\2F_enercalctrib 180131_.ec( Wood Beam ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.17.2.2f Lic. #: KW-06006655 Description : (2-3) CODE REFERENCES Calculations per NDS 2015, 1 BC 2015, CBC 2016, ASCE 7-10 Load Combination Set: IBC 2015 Material Properties Analysis Method: Allowable Stress Design Fb - Tension Load Combination JBC 2015 Fb - Compr Fc - Prll Wood Species Trus Joist Fc - Perp Wood Grade TimberStrand LSL 1.55E Fv Ft Beam Bracing Beam is Fully Braced against lateral -torsional buckling Q(0,02) S(OL25) 1.75xl 1.25 Span = 23.0 ft Pq bw ad low "d 2325 psi E: Modulus of Elasticity 2325 psi Ebend-xx 1550ksi 2170 psi Eminbend - xx 787.815ksi 900 psi 0" 310 psi 1070 psi Density 44.99 pcf 804 Applied Service loads entered. Load Factors will be applied for calculations. Uniform Load : D = 0.020, S = 0.0250, Tributary Width = 1.0 ft, (ROOF) DESIGN SUMMARY 'Maximum Bending Stress Ratio 0.3621 Maximum Shear Stress Ratio 0.111 :1 Section used for this span 1.75xl 1.25 Section used for this span 1.75xl 1.25 fb, : Actual 967.31 psi fv : Actual 39.43 psi FB : Allowable 2,673.75 psi Fv: Allowable 356.50 psi Load Combination +D+S Load Combination +D+S Location of maximum on span 11.500ft Location of maximum on span 0.000ft Span # where maximum occurs Span # 1 Span # where maximum occurs Span # 1 Maximum Deflection Max Downward Transient Deflection 0.492 in Ratio 561 >=360 Max Upward Transient Deflection 0.000 in Ratio= 0 <360 Max Downward Total Deflection 0.885 in Ratio= 311 ­240. Max Upward Total Deflection 0.000 in Ratio 0 <240.0 Overall Maximum Deflections Load Combination Span Max . ..... Defl Location in Span Load Combination Max. 'Y' Defl Location in Span +D+S 1 0.8855 11.584 0.0000 0.000 Vertical Reactions Support notation : Far left is #1 Values in KIPS Load Combination Supportl Support 2 Overall MAXimum 0.518 0.518 Overall MINimum 0.138 0.138 D Only 0.230 0.230 +D+S 0.518 0.518 +D+0.750S 0,446 0.446 +0.60D 0.138 0.138 S Only 0.288 0.288 File= SAJobs\s18\s1811\s1811020- 917 Pine Street4o 181203QF-enercalc trib 180131_.ec( Wc,od Beam ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.17.2.2E =�: KW-06006655 Description : (2-4) CODE REFERENCES Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10 Load Combination Set: IBC 2015 Material Properties Analysis Method: Allowable Stress Design Fb - Tension Load Combination IBC 2015 Fb - Compr Fc - PHI Wood Species Douglas Fir - Larch Fc - Perp Wood Grade No.2 Fv Ft Beam Bracing Beam is Fully Braced against lateral -torsional buckling 900.0 psi E: Modulus of Elasticity 900.0 psi Ebend-xx 1,600.0 ksi 1,350.0 psi Eminbend - xx 580.0 ksi 625.0 psi 180.0 psi 575.0 psi Density 31.20 pcf - --------------- D(O.23) (0.288) D(0.11 16) S(O.145) 6(0.02) S(0,025) D(O.02) S(O.025) �1(�0.02) S(O.025) 2x12 2x12 2x12 Span = 1 M ft Span = 12.0 ft Span 2.50 ft AplAied Loads_ Load for Span Number 1 Uniform Load: D = 0.020, S = 0.0250, Tributary Width = 1.0 ft, (ROOF) PDint Load : D = 0.230, S = 0.2880 k @ 0.0 ft, ((2-3)) Load for Span Number 2 Uniform Load : D = 0.020, S = 0.0250 , Tributary Width = 1.0 ft, (ROOF) Load for Span Number 3 Uniform Load : D = 0.020, S = 0.0250 , Tributary Width = 1.0 ft, (ROOF) PointLoad: D=0.1160, S=0.1450k@2.50ft,((2-2)) DESIGN SUMMARY .Maximum Bending Stress Ratio Section used for this span fb : Actual FB: Allowable Load Combination Location of maximum on span Span # where maximum occurs Maximum Deflection i Max Downward Transient Deflection Max Upward Transient Deffection Max Downward Total Deflection Max Upward Total Deflection Overall Maximum Deflections Service loads entered. Load Factors will be applied for calculations. 0303c 1 Maximum Shear Stress Ratio 0.251 : 1 2x12 Section used for this span 2x12 313.88psi fv : Actual 52.04 psi 1,035.00psi Fv: Allowable 207.00 psi +D+S Load Combination +D+S 1.500ft Location of maximum on span 1.500 ft Span # I Span # where maximum occurs Span # 1 0.019 in Ratio= 321 0 >=360, -0.009 in Ratio = 16804 ­360. 0.034 in Ratio= 1784 >=240. -0.015 in Ratio = 9356 ­240. Load Combination Span Max. "-" Defl Location in Span Load Combination Max. 'Y' DO Location in Span +D+S 1 0.0188 0.000 0.0000 0.000 2 0.0000 0.000 +D+S -0.0154 4.840 +D+S 3 0.0336 2.500 0.0000 4.840 Wood Beam File= SAJobs\s1&s18111s1811020-917 Pine Streefto 181203\2F-enerraictrib 180131-ed ENERCALC, INC. 1983-2017,Build:6,17.2.28,Ver:6.17.2.2E Lic. # : KW-06006655 Licensee: SOUND STRUCTURAL SOLUTIONS Description : (2-4) Vertical Reactions Support notation Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Support 3 Support 4 Overall MAXimum 0.858 0.641 Overall MINimum 0.229 0.171 D Only 0.381 0.285 +D+S 0.858 0.641 +D+0.750S 0.739 0.552 +0.60D 0.229 0.171 S Only 0.477 0.356 Wood Beam File= SAJo1bs\s1ffis1811\s1811020 - 917 Pine Streetwo 181203\181203 - 2F - enercalc trib - s1811020.ed ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.17.2.2f Lic. #: KW-06006655 Licensee,: SOUND STRUCTURAL SOLUTITIM Description : (2-5) A CODE REFERENCES Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10 Load Combination Set: IBC 2015 Material Properties Analysis Method: Allowable Stress Design Fb - Tension 2,900.0 psi E Modulus of Elasticity Load Combination IBC 2015 Fb - Compr 2,900.0 psi Ebend-xx 2,200.Oksi Fc - Pril 2,900.0 psi Eminbend - xx 1, 118.19 ksi Wood Species Trus Joist Fc - Perp 625.0 psi Wood Grade Parallam PSL 2.2E Fv 290.0 psi Ft 2,025.0 psi Density 45.050 pcf Beam Bracing Beam is Fully Braced against lateral -torsion a I buckling D(O.382),S(O.477) Q(Q. 12) S(Q. 15) Qfflj?�(0_15) 5.25xi 1.25 5.25xll.25 Span = 6.0 ft Span = 16.333 ft Applied Loads Load for Span Number 1 Uniform Load : D = 0.020, S = 0.0250 ksf, Tributary Width = 6.0 ft, (ROOF) Point Load : D = 0.3820, S = 0,4770 k @ 0.0 ft, ((2-3)) Load for Span Number 2 Uniform Load : D = 0.020, S = 0.0250 ksf, Tributary Width = 6.0 ft, (ROOF) Service loads entered. Load Factors will be applied for calculations. Maximum Bending Stress Ratio 0.325.1 Maximum Shear Stress Ratio 0.215 : 1 Section used for this span 5.25xl 1.25 Section used for this span 5.25xi 1.25 fb : Actual 1,085.11 psi fv : Actual 71.57 psi FIB: Allowable 3,335.00 psi Fv: Allowable 333.50 psi Load Combination +D+S Load Combination +D+S Location of maximum on span 6.000ft Location of maximum on span 6.000ft Span # where maximum occurs Span # 1 Span # where maximum occurs Span # 1 Maximum Deflection Max Downward Transient Deflection 0.097 in Ratio 1478 >=360. Max Upward Transient Deflection -0.001 in Ratio= 151203 >=360. Max Downward Total Deflection 0.175 in Ratio = 820 >=240. Max Upward Total Deflection -0.002 in Ratio= 83643 >=240. Overall Maximum Deflections Load Combination YNO +D+S +D+S Vertical Reactions Load Combination Overall MAXimurn Overall MINimurn D Only +D+S Span Max . ..... Defl Location in Span Load Combination 1 0.1753 0.000 2 0.1115 9.763 +D+S Support notation : Far left is #1 Support 1 Support 2 Support 3 5.297 1.592 1.413 0.424 2.355 0.707 5.297 1.592 Max. 'Y' Defl Location in Span 0.0000 0.000 -0.0023 0.639 Values in KIPS Wood Beam 111111TWUNTIVEMMM-TM Description : (2-5) A Vertical Reactions Load Combination +D+0.750S +0.60D S Only SAJobs\s18\s18Ms1811020-917 Pine Streetkwo 181203\l8l2O3-2F_enercalctdb_sl8llO2O.ecI ENERCALC, INC. 1983-2017. Build:6.17.2.28. Ver:6.17.2.2( Support notation : Far left is #1 Values in KIPS Support I Support 2 Support 3 4.561 1.371 1.413 0.424 2.943 0.884 Wood Beam File= SAJobsW8ks18111s1811020 - 917 Fine Streefto 181203\2F — enercalc trib 180131—ed ENERCALC INC. 1983-2017, Build:6.17.2.28, Ver:6.17.22E �Lic. #: KW-06006655 Licensee - SOUND STRUCTURAL SOLLITH Description (2-5) B CODE REFERENCES Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10 Load Combination Set: IBC 2015 Material Properties Analysis Method: Allowable Stress Design Fb - Tension 2900 psi E: Modulus of Elasticity Load Combination JBC 2015 Fb - Compr 2900 psi Ebend-xx 2200 ksi Fc - Prll 2900 psi Eminbend - xx 1118.19 ksi Wood Species Trus Joist Fc - Perp 625 psi Wood Grade Parallam PSL 2.21E Fv 290 psi Ft 2025 psi Density 45.05 pcf Beam Bracing Beam is Fully Braced against lateral -torsional buckling D( .382) Q(0.12) Q(Q. 12) SQ. 15) 04 5.25A 1.25 5.25A 1.25 Span = 6.0 ft Span = 16.333 Ift Applied Loads Service loads entered. Load Factors will be applied for calculations. Load for Span Number 1 Uniform Load : D = 0.020 ksf, Tributary Width = 6.0 ft, (ROOF) Point Load : D = 0.3820 k @ 0,0 ft, ((2-3)) Load for Span Number 2 Uniform Load : D = 0.020, S = 0.0250 ksf, Tributary Width = 6.0 ft, (ROOF) Ub,WUN SUMMANY N gn�, 01 Maximum Bending Stress Ratio 012a 1 Maximum Shear Stress Ratio 0.189 : 1 Section used for this span 5.25xl 1.25 Section used for this span 5.25xl 1.25 fb : Actual 749.32 psi fv : Actual 62.92 psi FB: Allowable 3,335.00 psi Fv: Allowable 333.50 psi Load Combination +D+S Load Combination +D+S Location of maximum on span 9.216ft Location of maximum on span 6.000 ft Span # where maximum occurs Span # 2 Span # where maximum occurs Span # 1 Maximum Deflection Max Downward Transient Deflection 0.177 in Ratio 1108 ­360. Max Upward Transient Deflection -0.206 in Ratio= 698 ­360. Max Downward Total Deflection 0.224 in Ratio= 874 ­240. Max Upward Total Deflection -0.128 in Ratio= 1124 >=240. Overall Maximum Deflections Load Combination Span Max. "-" Defi Location in Span Load Combination Max. 'Y' Defl Location in Span 1 0.0000 0.000 S Only -0.2060 0.000 +D+S 2 0.2242 8.669 0.0000 0.000 Vertical Reactions Support notation : Far left is #1 Values in KIPS Load Combination Overall MAXimum Overall MINimum D Only +D+S Support 1 Support 2 Support 3 3.580 1.932 1.225 0.424 2.355 0.707 3.580 1,932 Wood Beam rUXIMETITTITIT.T.T79M Description : (2-5) B Vertical Reactions Load Combination +D+0.750S +0.60D S Only File= S.Mobs�slffis`1811%18111020 - 917 Pine Streeftwo 181203\21`�enercalc trib 180131_.ecf ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.17.2.2E Support notabon : Far left is #1 Values in KIPS Support 1 Support 2 Support 3 3.273 1.626 1.413 0.424 1.225 1.225 [Wood Beam File = SAJobs\slffis18l%l811020 . 917 Pine Street\wo 181203QF—enercalc trib 180131.ec( ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.17.2.21! Lic. #: KW-06006655 -1:tcensee:: SOUND STRUCTURAL SOLUT1.6 Description (2-5) C CODE REFERENCES Calculations per INDS 2015, IBC 2015, CBC 2016, ASCE 7-10 Load Combination Set: IBC 2015 Material Properties Analysis Method: Allowable Stress Design Fb - Tension 2900 psi E Modulus of Elasticity Load Combination IBC 2015 Fb - Compr 2900 psi Ebend-xx 2200ksi Fc - PrIl 2900 psi Eminbend - xx 1118.19 ksi Wood Species Trus Joist Fc - Perp 625 psi Wood Grade Parallam PSL 2.21E Fv 290 psi Ft 2025 psi Density 45.05 pcf Beam Bracing Beam is Fully Braced against lateral -torsional buckling D(O.382).S(D.477) 0(0.12) S(O.1 5) W0.121 5.25xl 1-25 5.25xl 1.25 Span = 6.0 ft Span = 16333 ft Applied Loads Load for Span Number I Uniform Load: D = 0.020, S = 0.0250 ksf, Tributary Width = 6.0 ft, (ROOF) Point Load : D = 0.3820, S = 0.4770 k @ 0.0 ft, ((2-3)) Load for Span Number 2 Uniform Load : D = 0.020 ksf, Tributary Width = 6.0 ft, (ROOF) DESIGN SUMMARY Service loads entered. Load Factors will be applied for calculations. :Maximum Bending Stress Ratio 0.32S. 1 Maximum Shear Stress Ratio 0.189 :1 Section used for this span 5.25xl 1.25 Section used for this span 5.25xl 1.25 ftb : Actual 1,085.11 psi fv : Actual 62.96 psi FB: Allowable 3,335.00 psi Fv: Allowable 333.50 psi Load Combination +D+S Load Combination +D+S Location of maximum on span 6.000ft Location of maximum on span 6.000 ft Span # where maximum occurs Span # 1 Span # where maximum occurs Span # 1 Maximum Deflection Max Downward Transient Deflection 0.303 in Ratio= 474 >=360. Max Upward Transient Deflection -0.122 in Ratio= 1609 >=360. Max Downward Total Deflection 0.381 in Ratio= 376 >=240. Max Upward Total Deflection -0.088 in Ratio= 2218 ­240. Overall Maximum Deflections Load Combination Span Max.%" Dell Location in Span Load Combination Max. 'Y' Defl Location in Span +D+S 1 0.3813 0.000 0.0000 0.000 2 0.0000 0.000 S Only -0.1218 6.935 Vertical Reactions Support notation : Far left is #1 Values in KIPS Load Combination Support I Support 2 Support 3 Overall MAXimum 4.072 0.707 Overall MINimum 1.413 -0.341 D Only 2.355 0.707 +D+S 4.072 0.367 MR vw Wood Beam IMM.1,311573ii-MisT.T.-711111111 Description : (2-5) C Vertical Reactions Load Combination +D+0.750S +0.60D S Only File= SAJobs\s18\s1811\s1811020 - 917 Pine Streefto 181203QF_enercalc trib 180131_.ec( ENERCALG, INC. 1983-2017, Build:6.17.2.28, Ver:6.17.2,2f Licensee: SOUND STRUCTURAL SOLUTIONS Support notation : Far left is #1 Values in KIPS Support 1 Support 2 Support 3 3.643 0.452 1.413 0.424 1.718 -0.341 o 1A1 A 0 File = S:\JobsW81s181 UU VC211111 Lic. #: KW-06006655 Description : (2-7) CODE REFERENCES Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10 Load Combination Set: IBC 2015 Material Properties Analysis Method: Allowable Stress Design Fb - Tension Load Combination JBC 2015 Fb - Compr Fc - PrIl Wood Species Douglas Fir - Larch Fc - Perp Wood Grade No.2 Fv Ft Beam Bracing Beam is Fully Braced against lateral -torsional buckling D(O.04) L(D.12) S(O.05) 2x12 Span = 7.0 ft 900.0 psi 900.0 psi 1,350.0 psi 625.0 psi 180.0 psi 575.0 psi 0 - 917 Pine Street\wo 181203k2F_enercalc trib 180131_.e(i ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver.6.17.2.' 2E E: Modulus of Elasticity Ebend-xx 1,600.Oksi Eminbend - xx 580.Oksi Density 31.20 pcf Applied Loads Service loads entered. Load Factors will be applied for calculations. Uniform Load : D = 0.020, L = 0.060, S = 0.0250 ksf, Tributary Width = 2.0 ft, (ROOF DECK) DESIGN SUMMARY a�*� I -M Maximum Bending Stress Ratio 0.41 a. 1 Maximum Shear Stress Ratio 0.277 :1 Section used for this span 2x12 Section used for this span 2x1 2 fb, : Actual 371.67 psi fv : Actual 49.78 psi FB: Allowable 900.00 psi Fv: Allowable 180.00 psi Load Combination +D+L Load Combination +D+L Location of maximum on span 3.500ft Location of maximum on span 0.000ft Span # where maximum occurs Span # 1 Span # where maximum occurs Span # 1 Maximum Deflection Max Downward Transient Deflection 0.023 in Ratio= 3668 >=360 Max Upward Transient Deflection 0.000 in Ratio = 0 <360 Max Downward Total Deflection 0.032 in Ratio = 2628 >=240. Max Upward Total Deflection 0.000 in Ratio = 0 <240.0 Overall Maximum Deflections Load Combination Span Max . ..... Def] Location in Span Load Combination Max. 'Y' Defi Location in Span +D+0.750L+0.750S 1 0.0320 3.526 0.0000 0.000 Vertical Reactions Support notation : Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Overall MAXimum 0.586 0.586 Overall MINimurn 0.084 0.084 D Only 0.140 0.140 +D+L 0,560 0.560 +D+S 0.315 0.315 +D+0.750L+0.750S 0.586 0.586 +0.60D 0.084 0.084 L Only 0.420 0.420 S Only 0.175 0.175 FN too File= SAJobs\s18\s1811\s1811020 - 917 Pine Street\wo 181203\181203 — 2F — enercalc trib—s I 811020.ecl Wood Beam ENERCALC, INC. 1983-2017, Build:6.17.2,28, Ver:6.17.2.2E I RTWIM ATE I 1 1.111 1 R1 I "IM&*9111 " I II&I I ZAILM I Description : (2-12) CODE REFERENCES Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10 Load Combination Set: IBC 2015 Material Properties Analysis Method: Allowable Stress Design Fb - Tension 2,325.0 psi E: Modulus of Elasticity Load Combination JBC 2015 Fb - Compr 2,325.0 psi Ebend-xx 1,550.Oksi Fc - Prll 2,170.0 psi Eminbend - xx 787.82 ksi Wood Species Trus Joist Fc - Perp 900.0 psi Wood Grade TimberStrand LSL 1.55E Fv 310.0 psi Ft 1,070.0 psi Density 44.990 pcf Beam Bracing Beam is Fully Braced against lateral -torsional buckling D(O.114) 3.5x9.25 Span = 9.50 ft Applied Loads Service loads entered. Load Factors will be applied for calculations. Load for Span Number 1 Uniform Load: D = 0,0150, S = 0.0250 ksf, Extent = 0.0 ­> 2.750 ft, Tributary Width = 6.0 ft, (ROOF) Uniform Load: D = 0.020, S = 0.0250 ksf, Extent = 2.750 ­> 9�50 ft, Tributary Width = 12.0 ft, (rOOF) Point Load : D = 0.1140, L = -0.0890, S = 0.2020 k @_ 2.750 ft, ((2-10)) Ut")IL71V "AUMMAKY Maximum Bending Stress Ratio 0.53a 1 Maximum Shear Stress Ratio 0.330 : 1 Section used for this span 3.5x9.25 Section used for this span 3.5x9.25 fb : Actual 1,432.90 psi fv : Actual 117.55 psi FIB: Allowable 2,673.75 psi Fv: Allowable 356.50 psi Load Combination +D+S Load Combination +D+S Location of maximum on span 4.785ft Location of maximum on span 9.500 ft Span # where maximum occurs Span # 1 Span # where maximum occurs Span # 1 Maximum Deflection Max Downward Transient Deflection 0.153 in Ratio= 743 >=360 Max Upward Transient Deflection -0.006 in Ratio = 18871 ­360 Max Downward Total Deflection 0.270 in Ratio = 422 ­240. Max Upward Total Deflection 0.000 in Ratio= 0 <240.0 Overall Maximum Deflections Load Combination Span Max. "-" Defi Location in Span Load Combination Max. 'Y' Defl Location in Span +D+S 1 0.2700 4.785 0.0000 0.000 Reactions Support notation : Far left is #1 Values in KIPS —,Vertical Load Combination Support 1 Support 2 Overall MAXimum 2.084 2.537 Overall MINimum -0.063 -0.026 D Only 0.868 1.113 +D+L 0.805 1.088 +D+S 2.084 2.537 +D+0.750L+0.750S 1.733 2.162 Wood Beam Description (2-12) Vertical Reactions Load Combination +0.60D L Only S Only File= S,.UobsW81s18111s1811020 - 917 Pine Stre6wo 181203\181203,2F_percalc tdb�_M811020.ecf ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.17.2.2E Support notation : Far left is #1 Values in KIPS Supportl Support 2 0.521 0.668 -0.063 -0.026 1.216 1.424 File= SAJobsWffls1811�s1811020- 917 Pine Streefto 1811201181203217enercalc trib-s'1811020.ed Wood Beam ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.17.2.2E Lic. #: KW-06006655 Licensee: SOUND STRUCTURAL SOLUTIONS Description : (2-13) CODE REFERENCES Calculations per INDS 2015, IBC 2015, CBC 2016, ASCE 7-10 Load Combination Set: IBC 2015 Material Properties Analysis Method: Allowable Stress Design Fb - Tension 900.0 psi E: Modulus of Elasticity Load Combination IBC 2015 Fb - Compr 900.0 psi Ebend-xx 1,600.0 ksi Fc - Prll 1,350.0 psi Eminbend - xx 580.0 ksi Wood Species Douglas Fir - Larch Fc - Perp 625.0 psi Wood Grade No.2 Fv 180.0 psi Ft 575.0 psi Density 31.20 pcf Beam Bracing Beam is Fully Braced against lateral -torsional buckling 0(0.23) (0.288) D(O.0 V (0.05) V0.03V(0.j 4x12 4X12 Span = 9.50 ft Span = 2.0 ft Applied Loads Service loads entered. Load Factors will be applied for calculations. Load for Span Number 1 Uniform Load : D = 0.0150, S = 0,0250 ksf, Tributary Width = 2.0 ft, (ROOF) Load for Span Number 2 Uniform Load: D = 0.0150, S = 0.0250 ksf, Tributary Width = 2.0 ft, (ROOF) Point Load : D = 0,230, S = 0.2880 k @ 2.0 ft, ((2-3)) DESIGN SUMMARY aximum Bending Stress Ratio 0.171:1 Maximum Shear Stress Ratio 0.125 :1 Section used for this span 4x12 Section used for this span 4x12 fb : Actual 194.40 psi fv : Actual 25.83 psi FB: Allowable 1, 138.50 psi Fv: Allowable 207.00 psi Load Combination +D+S Load Combination +D+S Location of maximum on span 9.500ft Location of maximum on span 9.500ft Span # where maximum occurs Span # 1 Span # where maximum occurs Span # 1 Maximum Deflection Max Downward Transient Deflection 0.004 in Ratio = 11730 >=360 Max Upward Transient Deflection 0.000 in Ratio = 0 <360 Max Downward Total Deflection 0.009 in Ratio = 5438 >=240. Max Upward Total Deflection -0.001 in Ratio= 113391 >=240. Overall Maximum Deflections Load Combination Span Max. "-" Defl Location in Span Load Combination Max. 'Y' Defl Location in Span +D+S 1 0.0054 3.450 +D+S -0.0010 8.545 +D+S 2 0.0088 2.000 0.0000 8.545 Vertical Reactions Support notation : Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Support 3 Overall MAXimum 0.254 1.184 Overall MINimum 0.053 0.292 D Only 0.088 0.487 +D+S 0.254 1.184 Now Wood Beam File= 8AJobs\s1Ms1811\s1811O2O - 917 Pine Street1wo 181203\181203L2Fenercalc tdk-s16116k�Cf-1l11l ENERCALC, INC. 1983-2D17, Build:6.17.2,28, Ver:6.17.2.2i I Description : (2-13) Vertical Reactions Support notation : Far left is #1 Values in KIPS Load Combination Support I Support 2 Support 3 +D+0.750S 0.213 1.010 +0.60D 0.053 0.292 S Only 0.166 0.697 r, 400 on aw Wood Beam File = S:\Jobs\sl B\sl Lic. #: KW-06006655 Description : (2-16) CODE REFERENCES Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10 Load Combination Set: IBC 2015 Material Properties Analysis Method: Allowable Stress Design Fb - Tension Load Combination IBC 2015 Fb - Compr Fc - PrIl Wood Species Trus Joist Fc - Perp Wood Grade Parallam PSL 2.2E Fv Ft Beam Bracing Beam is Fully Braced against lateral -torsional buckling 811020 - 917 Pine Streetkwo 181203k18i203_2F_enercaIc triLs'1811020.ed ENERCALC, INC. 1983-2017, Build:6.17.2,28, Ver:6.1722E 2,900.0 psi E: Modulus of Elasticity 2,900.0 psi Ebend-xx 2,200.0 ksi 2,900.0 psi Eminbend - xx 1, 118.19 ksi 625.0 psi OR 290.0 psi 2,025.0 psi Density 45.050 pcf D(O.1 i� (0. 15, ID, Q(0.28) S(O.35) T 15A.25 3.5x9.25 Span = 17.0 ft Span = 6.333 ft Applied Loads Service loads entered. Load Factors will be applied for calculations. Load for Span Number 1 Varying Uniform Load : D(S,E) = 0.0840-0.020, S(S,E) = 0.1210-0.050 ksf, Extent 9.50 --- 17.0 ft, Trib Width 2.0 ft, (ROOF) Uniform Load : D = 0.020, S = 0.0250 ksf, Extent = 0.0 -->> 9.50 ft, Tributary Width 6.0 ft, (ROOF) Load for Span Number 2 Uniform Load : D = 0.020, S = 0.0250 ksf, Tributary Width = 14.0 ft, (ROOF) DESIGN SUMMARY 2Maximum Bending Stress Ratio 1 Maximum Shear Stress Ratio 0.462 : 1 Section used for this span 3.5x9.25 Section used for this span 3.5x9.25 fb : Actual 2,024.04 psi fv : Actual 154.02 psi FIB : Allowable 3,335.00 psi Fv: Allowable 333.50 psi Pq Load Combination +D+S Load Combination +D+S t Location of maximum on span 17.000ft Location of maximum on span 17.000ft I Span #where maximum occurs Span # I Span # where maximum occurs Span # 1 Maximum Deflection Max Downward Transient Deflection 0.325 in Ratio= 627 >=360 Max Upward Transient Deflection -0.020 in Ratio= 3812 >=360 Max Downward Total Deflection 0.563 in Ratio 362 >=240. i Max Upward Total Deflection -0.033 in Ratio= 2331 >=240. Overall Maximum Deflections so Load Combination Span Max . ..... Defi Location in Span Load Combination Max. 'Y' Defl Location in Span +D+S 1 0.5630 7.693 0.0000 0.000 2 0.0000 7.693 +D+S -0,0326 2.052 Vertical Reactions Support notation : Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Support 3 Overall MAXimum 1.883 6.069 0.666 Overall MINimum 0.493 1.525 0.198 D Only 0.821 2.542 0.330 +D+S 1.883 6.069 0.666 %M Not IN &am Wood Beam File= SAJobs\s18\s1811\s1811020-917 Pine Streetwo 181203k181202L2Fjnercalc td�_s1811020.w ENERGALC, INC. 1983-2017, Build:6.17.2.28. Vw:6.17.2.2E Description : (2-16) Vertical Reactions Support notation : Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Support 3 +D+0.750S 1.617 5.187 0,582 +0.60D 0.493 1.525 0.198 S Only 1.061 3.527 0.336 PIN rill I" "MI, File= S:\JoWs1&s181 %1811020 - 917 Pine Skeefto 1812031181203 2F enercalc trib s1811020.ed Wood Beam ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.17.2.2E Lic. #: KW-06006655 Description : (2-17) CODE REFERENCES Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10 Load Combination Set: IBC 2015 Material Properties Analysis Method: Allowable Stress Design Fb - Tension Load Combination JBC 2015 Fb - Compr Fc - Prll Wood Species Trus Joist Fc - Perp Wood Grade TimberStrand LSL 1.55E Fv Ft Beam Bracing Beam is Fully Braced against lateral -torsional buckling D(O.1979 Y (0.24752) 3.50.25 Span = 9.333 ft 2,325.0 psi E: Modulus of Elasticity 2,325.0 psi Ebend-xx 1,550.0 ksi 2,170.0 psi Eminbend - xx 787.82 ksi 900.0 psi 310. 0 psi 1,070.0 psi Density 44.990 pcf Applied Loads Service loads entered. Load Factors will be applied for calculations. Uniform Load : D = 0.01414, S = 0.01768 ksf, Tributary Width = 14.0 ft, (ROOF) DESIGN SUMMARY .Maximum Bending Stress Ratio 0.43111, 1 Maximum Shear Stress Ratio 0270 : 1 Section used for this span 3.5x9.25 Section used for this span 3.5x9.25 flb : Actual 1, 166.25 psi fv : Actual 96.32 psi FB: Allowable 2,673.75 psi Fv: Allowable 356.50 psi Load Combination +D+S Load Combination +D+S Location of maximum on span 4.667ft Location of maximum on span 0.000ft Span # where maximum occurs Span # 1 Span # where maximum occurs Span # 1 Maximum Deflection Max Downward Transient Deflection 0.119 in Ratio= 942 ­360 i Max Upward Transient Deflectioin 0.000 in Ratio= 0 <360 Max Downward Total Deflection 0.214 in Ratio= 523 >=240. Max Upward Total Deflection 0.000 in Ratio 0 <240.0 Overall Maximum Deflections Load Combination Span +D+S 1 Vertical Reactions Load Combination Overall MAXimum Overall MINimum D Only +D+S +D+0.750S +0.60D S Only Max."2' Defl Location in Span Load Combination 02138 4.701 Support notation Far left is #1 Support 1 Support 2 2.079 2.079 0.554 0.554 0.924 0.924 2,079 2.079 1.790 1.790 0.554 0.554 1.155 1.155 Max."+" Defi Location in Span Values in KIPS Awl Wood Beam File = S:\Jobs\s18\s1811\s1811020 - 917 Pine Streefto 181203\2F enercalc trib 180131 ed ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.172.2j 7 = I Description (2-18) - - ---- CODE REFERENCES Calculations per INIDS 2015, IBC 2015, CBC 2016, ASCE 7-10 Load Combination Set: IBC 2015 Material Properties Analysis Method: Allowable Stress Design Fb - Tension 900 psi E.- Modulus of Elasticity Load Combination IBC 2015 Fb - Compr 900 psi Ebend-xx 11600ksi Fc - PrIl 1350 psi Eminbend - xx 580 ksi Wood Species Douglas Fir - Larch Fc - Perp 625 psi Wood Grade No.2 Fv 180 psi Ft 575 psi Density 31.2 pcf Beam Bracing Beam is Fully Braced against lateral -torsional buckling D(O.06) s(O.075) 4x4 Spa— 5 0 ft Applied Loads Service loads entered. Load ractors will be applied for calculations. Uniform Load : D = 0.020, S = 0.0250 ksf, Tributary Width = 3.0 ft, (ROOF) Uk,WUN Z:iUMMAHY Maximum Bending Stress Ratio 0.456Z 1 Maximum Shear Stress Ratio 0.200 : 1 Section used for this span 4x4 Section used for this span 4x4 flo : Actual 708.45 psi fv : Actual 41.33 psi FB: Allowable 1,552.50psi Fv: Allowable 207.00 psi Load Combination +D+S Load Combination +D+S Location of maximum on span 2.500 ft Location of maximum on span 0.000 ft Span # where maximum occurs Span # 1 Span # where maximum occurs Span # 1 Maximum Deflection Max Downward Transient Deflection 0.053 in Ratio= 1131 >=360 Max Upward Transient Deflection 0.000 in Ratio= 0 <360 Max Downward Total Deflection 0.095 in Ratio= 628 >=240. Max Upward Total Deflection 0.000 in Ratio= 0 <240.0 Overall Maximum Deflections Load Combination Span Max. "-" Dell Location in Span Load Combination Max. 'Y' Defl Location in Span +D+S 1 0.0954 2.518 0.0000 0.000 Vertical Reactions Support notation : Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Overall MAXimum 0.338 0.338 Overall MINimum 0.090 0.090 D Only 0.150 0.150 +D+S 0.338 0.338 +D+0.750S 0.291 0.291 +0.60D 0.090 0.090 S Only 0.188 0.188 S" UW File= SAJobs\s18W811\s1811020 - 9117 Pine Street\wo 181201181203 1F enerm1ctrib_s1811020.ed Wood Beam ENEIRCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.17.2.2E 'Lic.#:KW-06006655 Description : (1 -1) CODE REFERENCES Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10 Load Combination Set: IBC 2015 Material Properties Analysis Method: Allowable Stress Design Fb - Tension Load Combination IBC 2015 Fb - Compr Fc - Prll Wood Species Trus Joist Fc - Perp Wood Grade TimberStrand LSL 1.55E Fv Ft Beam Bracing Beam is Fully Braced against lateral -torsional buckling 2325 psi 2325 psi 2170 psi 900 psi 310 psi 1070 psi D(O.02) L( V 6)S(O.025) f -------- 1.75xll.875 Span = 3.750 ft E: Modulus of Elasticity Ebend-xx 1550ksi Eminbend - xx 787.815ksi Density 44.99 pcf Applied Loads Service loads entered. Load Factors will be applied for calculations. UniformLoad: D=0.020, L=0.060r S=0.0250, Tributary Width= 1.0 ft, (ROOF DECK) DESIGN SUMMARY mmm��� Maximum Bending Stress Ratio 0.018Z 1 Maximum Shear Stress Ratio 0.035 : 1 Section used for this span 1.75xl 1.875 Section used for this span 1.75xl 1.875 flo : Actual 41.03psi fv : Actual 10.83 psi 1713: Allowable 2,325.00 psi Fv: Allowable 310.00 psi Load Combination +D+L Load Combination +D+L Location of maximum on span 1.875ft Location of maximum on span 0.000 ft Span # where maximum occurs Span # I Span # where maximum occurs Span # I Maximum Deflection Max Downward Transient Deflection 0.000 in Ratio 0 <360 Max Upward Transient Deflection 0.000 in Ratio= 0 <360 Max Downward Total Deflection 0.001 in Ratio= 45444 >=240. Max Upward Total Deflection 0.000 in Ratio= 0 <240.0 Overall Maximum Deflections Load Combination Spar +D+0.750L+0.750S Vertical Reactions Load Combination Overall MAXimum Overall MINimum D Only +D+L +D+S +D+0.750L+0.750S +0.60D L Only S Only Max, %" Defl Location in Span Load Combination Max. 'Y' Dell Location in Span 00010 1.889 0.0000 0.060 Support notation : Far left is #1 Values in KIPS No fto 00 am M %Md Support 1 Support 2 0.157 0.157 0.023 0.023 0.038 0.038 0.150 0.150 0.084 0.084 . 0.157 0.157 00 0.023 0.023 0.113 0.113 0.047 0.047 am MW �.j bow go %ad Wood Beam File= SAJobs\s1Ms18Ms1811020 917 Pine Street\wo 181203k181203 I Fenercalc trib-s1811020.ect ENERCALC, INC. 1983-2017, Build:6.17.2,28, Ver:6.17.2.2 Lic. # : KW-06006655 Licensee,." SOUND STRUCTURAL SOLUTI�Ijj Description : (1-2) CODE REFERENCES Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10 Load Combination Set: IBC 2015 Material Properties low Analysis Method: Allowable Stress Design Fb - Tension 2325 psi E Modulus of Elasticity Load Combination IBC 2015 Fb - Compr 2325 psi Ebend-xx 1550ksi Fc - PrIl 2170 psi Eminbend - xx 787.815ksi Wood Species Trus Joist Fc - Perp 900 psi Wood Grade TimberStrand LSL 1.55E Fv 310 psi Ft 1070 psi Density 44.99 pcf Beam Bracing Beam is Fully Braced against lateral -torsional buckling D(O. 15) L(O f )S(D.1875) 1.75xll.B75 Spa-- 3 750 ft Applied Loads Service loads entered. Load Factors will be applied for calculations. Uniform Load : D = 0.020, L = 0.060, S = 0.0250 ksf, Tributary Width = 7.50 ft, (ROOF DECK) Maximum Bending Stress Ratio 0.1321 Maximum Shear Stress Ratio 0.262 :1 wo Section used for this span 1.75xl 1.875 Section used for this span 1.75xi 1.875 fb : Actual 307.72 psi fv : Actual 81.20 psi F`13: Allowable 2,325.00psi Fv: Allowable 310.00 psi Load Combination +D+L Load Combination +D+L Location of maximum on span 1.875ft Location of maximum on span 0.000 ft Span # where maximum occurs Span # I Span # where maximum occurs Span # 1 Maximum Deflection Max Downward Transient Deflection 0.005 in Ratio = 8457 >=360 Max Upward Transient Deflection 0.000 in Ratio = 0 <360 Max Downward Total Deflection 0.007 in Ratio= 6059 ­240. i Max Upward Total Deflection 0.000 in Ratio= 0 <240.0 Maximum Deflections Load Combination Span Max. "2' Defl Location in Span Load Combination Max. 'T' Defl Location in Span +D+0.750L+0.750S 1 0.0074 1.889 0.0000 0.000 ON Vertical Reactions Support notation Far left is #1 Values in KIPS Load Combination Support 1 Support 2 "W Overall MAXimum 1.178 1.178 Overall MINinnum 0.169 0.169 D Only 0.281 0.281 +D+L 1.125 1.125 '.W +D+S 0.633 0.633 +D+0.750L+0.750S 1.178 1.178 +0.60D 0.169 0.169 L Only 0.844 0.844 S Only 0.352 0.352 MEN File= SAJobs\s18\s1811\s1811020 - 917 Pine Street\wo 181203\181203 1F-enercalc trib_s1811020.ed Wood Beam ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.17.2.2E Lic. #: KW-06006655 Licensee: SOUND STRUCTURAL SOLUTION Description : (1-3) CODE REFERENCES Calculations per NDS 2015, IBC 2015, CEIC 2016, ASCE 7-10 Load Combination Set: IBC 2015 Material Properties Analysis Method: Allowable Stress Design Fb - Tension 2,325.0 psi E Modulus of Elasticity Load Combination JBC 2015 Fb - Compr 2,325.0 psi Ebend-xx 1,550.Oksi Fc - PHI 2,170.0 psi Eminbend - xx 787.82 ksi Wood Species Trus Joist Fc - Perp 900.0 psi Wood Grade TimberStrand LSL 1.55E Fv 310. 0 psi Ft 1,070.0 psi Density 44.990 pcf Beam Bracing Beam is Fully Braced against lateral -torsional buckling Repetitive Member Stress Increase D(O.02) L(O.06) S(O.025) 1.75xl 1.875 Span = 18.250 ft Loads Service loads entered. Load Factors will be applied for calculations. --Applied Uniform Load : D = 0,020, L = 0.060, S 0.0250 , Tributary Width = 1.0 ft, (ROOF DECK) DESIGN SUMMARY Maximurn Bending Stress Ratio 0.36a. 1 Maximum Shear Stress Ratio 0.170 : 1 Section used for this span 1.75xl 1.875 Section used for this span 1.75xll.875 flo : Actual 971.75 psi fv : Actual 52.69 psi FB: Allowable 2,673.75 psi Fv: Allowable 310.00 psi Load Combination +D+L Load Combination +D+L Location of maximum on span 9.125ft Location of maximum on span 0.000 ft Span # where maximum occurs Span # 1 Span # where maximum occurs Span # 1 Maximum Deflection Max Downward Transient Deflecbon 0.398 in Ratio= 550 >=360 Max Upward Transient Deflection 0.000 in Ratio = 0 <360 Max Downward Total Deflection 0.555 in Ratio= 394 >=240. Max Upward Total Deflection 0.000 in Ratio 0 <240.0 Overall Maximum Deflections-_ Load Combination Span Max. Defl Location in Span Load Combination Max. 'Y' Defl Location in Span +D+0.750L+0.750S 1 0.5555 9.192 0.0000 0.000 Vertical Reactions Support notation Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Overall MAXimum 0.764 0.764 Overall MINimum 0.110 0.110 D Only 0.183 0.183 +D+L 0.730 0.730 +D+S 0.411 0.411 +D+0.750L+0.750S 0.764 0.764 +0.60D 0,110 0.110 L Only 0.548 0.548 S Only 0.228 0.228 Wood Beam File= 8:\Jobs\s18\s1811\s1811020 - 917 Pine Street%wo 181203\181203 1F_enercale trib_s1811020,ei,,I ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.17.2.2f Lic. #: KW-06066US Licensee : SOUND STRUCTURAL SOLUTI Description : (1-4) CODE REFERENCES Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10 Load Combination Set: IBC 2015 Material Properties Analysis Method: Allowable Stress Design Fb - Tension 2,325.0 psi E Modulus of Elasticity Load Combination JBC 2015 Fb - Compr 2,325.0 psi Ebend-xx 1,550.Oksi Fc - PrIl 2,170.0 psi Eminbend - xx 787.82 ksi Wood Species Trus Joist Fc - Perp 900.0 psi Wood Grade TimberStrand LSL 1.55E Fv 310. 0 psi Ft 1,070.0 psi Density 44.990 pcf Beam Bracing Beam is Fully Braced against lateral -torsional buckling Repetitive Member Stress Increase D(M`15) S(O.025) 1.75xl 1.875 Span = 22.50 ft Applied Loads Service loads entered. Load Factors will be applied for calculations. Uniform Load : D = 0.0150, S = 0.0250, Tributary Width = 1.0 ft, (ROOF) DESIGN SUMMARY 'Maximum Bending Stress Ratio 0.24a. 1 Maximum Shear Stress Ratio 0.091 : 1 Section used for this span 1.75xll.875 Section used for this span 1.75xl 1.875 fto : Actual 738.52 psi fv : Actual 32.48 psi FB: Allowable 3,074.81 psi Fv: Allowable 356.50 psi Load Combination +D+S Load Combination +D+S 1 Location of maximum on span 11.250ft Location of maximum on span 0.000 ft Span # where maximum occurs Span # I Span # where maximum occurs Span # 1 Maximum Deflection Max Downward Transient Deflection 0.383 in Ratio = 704 >=360 Max Upward Transient Deflection 0.000 in Ratio = 0 <360 Max Downward Total Deflection 0.613 in Ratio = 440 >=240. Max Upward Total Deflection 0.000 in Ratio= 0 <240.0 —Overall Maximum Deflections Load Combination Span Max. 'Y' Defi 'Location in Span Load Combination Max. 'Y' Defl Location in Span +D+S 1 0.6129 11.332 0.0000 0.000 -verticall Reactions Support notation : Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Overall MAXinnum 0.450 0.450 Overall MINinnurn 0.101 0.101 D Only 0.169 0.169 +D+S 0.450 0.450 +D+0.750S 0.380 0.380 +0.60D 0.101 0,101 S Only 0.281 0,281 File= SAlobs\08\0811\0811020-9117 Pine StreeAwo 181203\181203 I F_enercalctrib_s1811020eC( Wood Beam ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.17.2.2f Lie. # : KW-06006655 Licensee: SOUND STRUCTURAL SOLUTIONS Description : (1-5) CODE REFERENCES Calculations per NDS 2015, 1 BC 2015, CBC 2016, ASCE 7-10 Load Combination Set: IBC 2015 Material Properties Analysis Method: Allowable Stress Design Fb - Tension 2,325.0 psi E: Modulus of Elasticity Load Combination JBC 2015 Fb - Compr 2,325.0 psi Ebend-xx 1,550.Oksi Fc - Pdl 2,170.0 psi Eminbend - xx 787.82 ksi Wood Species Trus Joist Fc - Perp 900.0 psi Wood Grade TimberStrand LSL 1.55E Fv 310. 0 psi Ft 1,070.0 psi Density 44.990 pcf Beam Bracing Beam is Fully Braced against lateral -torsional buckling Repetitive Member Stress Increase I D(O. 169) S(0.282) D(O.015) L( 6)S(O.025) �(V15) S(O.025) 1.75xl 1.875 1.75xll.875 Span = 14.50 ft Span = 2.0 ft Applied Loads Service loads entered. Load Factors will be applied for calculations. aw Load for Span Number 1 Uniform Load: D = 0.0150, L = 0.060, S = 0.0250 , Tributary Width = 1.0 ft, (ROOF) 401 Load for Span Number 2 Uniform Load : D = 0.0150, S = 0.0250, Tributary Width = 1.0 ft, (ROOF) MW Point Load : D = 0,11690, 3 = 0.2820 R 2.0 ft, ((1 -4)) DESIGN SUMMARY Maximum Bending Stress Ratio 0. 1 9S 1 Maximum Shear Stress Ratio 0.133 : 1 Section used for this span 1.75xi 1.875 Section used for this span 1.75xl 1.875 fb : Actual 522.65 psi fv : Actual 41.08 psi FB: Allowable 2,673.75 psi Fv: Allowable 310.00 psi 00 Load Combination +D+L Load Combination +D+L Location of maximum on span 6.885ft Location of maximum on span 14,500ft Span # where maximum occurs Span # 1 Span # where maximum occurs Span # 1 Maximum Deflection Max Downward Transient Deflection 0.159 in Ratio 1093 >=360 Max Upward Transient Deflection -0.070 in Ratio= 688 >=360 Max Downward Total Deflection 0.177 in Ratio= 984 >=240. Max Upward Total Deflection -0.069 in Ratio= 700 >=240. Overall Maximum Deflections Load Combination Span Max. Defi Location in Span Load Combination Max. 'Y' Defl Location in Span +D+L 1 0.1767 7.128 0.0000 0.000 2 0.0000 7.128 L Only -0.0696 2.000 Vertical Reactions Support notation : Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Support 3 Ing Overall MAXimum 0.518 1.076 Overall MINimurn 0.050 0.200 D Only 0.083 0.333 +D+L 0.518 0.768 .IN kod Wood Beam Description Vertical Reactions Load Combination taw +D+S +D+0.750L+0.750S +0.60D L Only S Only r File= SAJobsks1ffis1811ks18 11020 - 917 Pine Streellkwo 181201181203 1 F_enercalc triLM11020.ed ENEIRCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.17.2.2f Support notation : Far left is #1 Values in KIPS Support I Support 2 Support 3 0.222 0.889 0.514 1.076 0.050 0.200 0.435 0.435 0.139 0.556 Wood Beam File= S-.Uobs\s18\s1811Ns1811020 - 917 Pine Street1wo 181203\181203 1F enercalctrib_sIB11020.eci ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.17.2.2f Lic. # : KW-06006655 Licensee: SOUND STRUCTURAL SOLUTIONS Description (1 -6) A CODE REFERENCES Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10 Load Combination Set: IBC 2015 Material Properties Analysis Method: Allowable Stress Design Fb - Tension 2,900.0 psi E Modulus of Elasticity Load Combination JBC 2015 Fb - Compr 2,900.0 psi Ebend-xx 2,200.0 ksi Fc - Prll 2,900.0 psi Eminbend - xx 1,118.19 ksi Wood Species Trus Joist Fc - Perp 625.0 psi Wood Grade Parallam PSL 2.2E Fv 290.0 psi Ft 2,025.0 psi Density 45.050 pcf Beam Bracing Beam is Fully Braced against late ra 1-torsiona I buckling D(O.115) Q0.145) S(O.14375) 0.12) L(O.36) S(O.1 D(O.015)L( 6)S(O.025) D(O.015) S(o.o2liO.031) L(O 0435) S(O.517) 7xl 1.875 7x1 1.875 Span = 16.667 ft Span = 6.0 ft Applied Loads Service loads entered. Load Factors will be applied for calculations. Load for Span Number 1 Uniform Load D = 0.0150, L = 0.060, S = 0.0250, Tributary Width = 1.0 ft, (ROOF) Uniform Load D = 0.020, L = 0.060, S = 0.0250 ksf, Tributary Width = 5.750 ft, (ROOF DECK) Load for Span Number 2 Uniform Load : D = 0.0150, 3 = 0.0250, Tributary Width = 1.0 ft, (ROOF) Point Load : D = 0.0310, L = 0,04350, S = 0.5170 k @ 6.0 ft, ((1-5)) Uniform Load : D = 0.020, L = 0.06G, S = 0.0250 ksf, Tributary Width = H ft, (ROOF DECK) tIff #ARAB A F211 'Maximum Bending Stress Ratio Section used for this span fb : Actual FB; Allowable Load Combination Location of maximum on span Span # where maximum occurs Maximum Deflection Max Downward Transient Deflection Max Upward Transient Deflection Max Downward Total Deflection Max Upward Total Deflection Overall Maximum Deflections Load Combination Span +D+L 1 2 Vertical Reactions Load Combination Overall MAXimum Overall MINimum 0.4711 1 Maximum Shear Stress Ratio 0.416 : 1 5.25xl 1.875 Section used for this span 5.25xll.875 1111101 1,380.26psi fv : Actual 120.78 psi 2,900.00 psi Fv: Allowable 290.00 psi 000 +D+L Load Combination +D+L 7.263 ft Location of maximum on span 16.667ft Am Span # I Span # where maximum occurs Span # I 1001 0.315 in Ratio = 635 >=360 -0.196 in Ratio = 734 >=360 ON 0.408 in Ratio= 490 -240. -0.238 in Ratio= 604 >=240. NEW Max. �-" Defl Location in Span Load Combination Max. "+" Defl Location in Span 0.4076 7.914 0.0000 0.000 0.0000 7.914 +D+L -0.2381 6.000 Support notation : Far left is #1 Values in KIPS Supportl Support 2 Support 3 3.928 9.080 0.556 1.249 No AM low Wood Beam Description (1-6)A Vertical Reactions Load Combination D Only +D+L +D+S +D+0.750L+0.750S +0.60D L Only S Only PR V S:Uobs1s1Ms181%1811020 - 917 Pine Streetwo 1812031`1812D3 I F_enercalc tril�_0811020.eil ENERCALC, INC. 1983-2017, Build:6.17.2.28. Ver.6.17.2.' 2f Support notation : Far left is #1 Support 1 Support 2 Support 3 0.926 2.081 3.897 8.064 1.958 5.430 3.928 9.080 0.556 1.249 2.971 5.983 1.031 3.348 Values in KIPS i IN �.w File = S.XJobs1s1&s181%1811020 - 917 Pine Street\wo 181203\181203 IF-enercalc trib s1811020.ec6 Wood Beam ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.17.2.28 Lic. # : KW-06006655 Licensee: SOUND STRUCTURAL SOLUTIONS Description : (1-6) B CODE REFERENCES Calculations per INDS 2015, IBC 2015, CBC 2016, ASCE 7-10 Load Combination Set: IBC 2015 Material Properties Analysis Method: Allowable Stress Design Fb - Tension 2,900.0 psi E: Modulus of Elasticity Load Combination JBC 2015 Fb - Compr 2,900.0 psi Ebend-xx 2,200.0 ksi Fc - Prll 2,900.0 psi Eminbend - xx 1, 118.19 ksi Wood Species Trus Joist Fc - Perp 625.0 psi Wood Grade Parallam PSL 2.2E Fv 290.0 psi Ft 2,025.0 psi Density 45.050 pcf Beam Bracing Beam is Fully Braced against lateral -torsional buckling D(O.08625) L(O 5) S(O.14375) D(O.09) D(O.015) L(O.06) S(O.025) D(O.015) D(O.0131) 7 7x1 1.875 7A 1.875 Span = 16.667 ft Span = 6.0 ft Applied Loads Service loads entered. Load Factors will be applied for calculations. Load for Span Number 1 Uniform Load: D = 0.0150, L = 0.060, S = 0.0250, Tributary Width = 1.0 ft, (ROOF) P" Uniform Load: D=0.0150, L = 0.060, S = 0.0250 ksf, Tributary Width 5.750 ft, (DECK) Load for Span Number 2 Uniform Load: D = 0.0150, Tributary Width = 1.0 ft, (ROOF) Point Load: D = 0.0310 k 0- 6.0 ft, (0-5)) Uniform Load : D = 0.0150 ksf, Tributary Width 6.0 ft, (ROOF DECK) DESIGN SUMMARY _lMaximum Bending Stress Ratio 0.416.1 Maximum Shear Stress Ratio 0.270 :1 Section used for this span 7xl 1.875 Section used for this span 7xl 1.875 fb : Actual 1,207.56 psi fv : Actual 78.38 psi FB: Allowable 2,900.00 psi Fv: Allowable 290.00 psi Load Combination +D+L Load Combination +D+L Location of maximum on span 8.101 ft Location of maximum on span 16.667 ft op Span # where maximum occurs Span # 1 Span # where maximum occurs Span # 1 Maximum Deflection Max Downward Transient Deflection 0.330 in Ratio 605 >=360 Max Upward Transient Deflection -0.377 in Ratio= 382 >=360 PIN Max Downward Total Deflection 0.404 in Ratio= 494 >=240. Max Upward Total Deflection -0.424 in Ratio= 338 >=240. PW Overall Maximum Deflections wo . Load Combination Span Max. Defl Location in Span Load Combination Max. Defl Location in Span +D+0.750L+0.750S 1 0.4041 8.287 0.0000 0.000 2 0.0000 8.287 +D+0.750L+0.750S -0.4236 6.000 Vertical. Support notation : Far left is #1 Values in KIPS -Reactions Load Combination Support 1 Support 2 Support 3 Overall MAXimum 4.305 5.215 Overall MINimum 0.432 0.978 on No Wood Beam Description : (1-6) B Vertical Reactions Load Combination D Only +D+L +D+S +D+0.750L+0.750S 4601) L Only S Only File � &\Jobs�s 1 ft181110811020-917 Pine SIneeftwo 181203\181203 IF enercalc trib sl 811020.ec6 ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.17.2.28 Support notation : Far left is #1 Values in KIPS Support 1 Support 2 Support 3 0.719 1.629 4.094 5.004 2.125 3,036 4.305 5,215 0,432 0.978 3.375 3.375 1.406 1.406 File= S-.Uobs1sl81s1811\s1811020 -917 Pine Street\wo 18120181203 1F enercalctrib—s1811020.ecl Nood Beam ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.17.2.2f Lic. # : KW-06006655 Licensee: SOUND STRUCTURAL SOLUTION' Description : (1 -6) C CODE REFERENCES Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10 Load Combination Set: IBC 2015 Material Properties Analysis Method: Allowable Stress Design Fb - Tension Load Combination IBC 2015 Fb - Compr Fc - Prll Wood Species Trus Joist Fc - Perp Wood Grade Parallam PSL 2.2E Fv Ft Beam Bracing Beam is Fully Braced against lateral -torsiona I buckling I" No Pq fto so aw Pq No 2,900.0 psi E: Modulus of Elasticity 2,900.0 psi Ebend-xx 2,200.0 ksi 2,900.0 psi Eminbend - xx 1, 118.19 ksi 625.0 psi 290.0 psi 2,025.0 psi Density 45.050 pcf Q (0; 12) 0.12) L( V 6)S(O.1 � ----+ D(O.015) D(0.015)S(o.oA0Q.031) Q0.0435) S(O.517) 7x1 1.875 Span = 16.667 ft 7xl 1.875 Span = 6.0 ft Applied Loads Service loads entered. Load Factors will be applied for calculations. Load for Span Number 1 Uniform Load : D = 0.0150, Tributary Width = 1.0 ft, (ROOF) Uniform Load: D = 0.020 ksf, Tributary Width = 6.0 ft, (ROOF DECK) Load for Span Number 2 Uniform Load : D = 0.0150, S = 0.0250, Tributary Width = 1.0 ft, (ROOF) Point Load: D = 0.0310, L = 0.04350, S = 0.5170 k @ 6.0 ft, ((1 -5)) Uniform Load : D = 0.020, L = 0.060, S = 0.0250 ksf, Tributary Width = 6.0 ft, (ROOF DECK) DESIGN SUMMARY !- Maximum Bending Stress Ratio 0.270.1 Maximum Shear Stress Ratio Section used for this span 7x1 1.875 Section used for this span fb : Actual 901.60 psi fv : Actual FB: Allowable 3,335.00 psi Fv: Allowable Load Combination +D+0.750L+0.750S Load Combination Location of maximum on span 16.667ft Location of maximum on span Span # where maximum occurs Span # 1 Span # where maximum occurs Maximum Deflection Max Downward Transient Deflection 0.230 in Ratio= 626 >=360 Max Upward Transient Deflection -0.097 in Ratio= 2055 >=360 Max Downward Total Deflection 0.301 in Ratio = 4.76 >=240. Max Upward Total Deflection -0.076 in Ratio= 2629 >=240. Overall Maximum Deflections 0.199 : 1 7x1 1.875 66.21 psi 333.50 psi +D+0.750L+0.750S 16,667ft Span # I Load Combination Span Max. "-" Defi Location in Span Load Combination Max. "+" Dell Location in Span D Only 1 0.0112 0.745 L Only -0.0973 9.683 +D+0.750L+0.750S 2 0.3013 6.000 0.0000 9.683 Vertical Reactions Support notation : Far left is #1 Values in KIPS Load Combination Support I Support 2 Support 3 Overall MAXimum 0.968 5.536 Overall MINimum -0.375 1.274 a" am ISM %W Wood Beam rlll�. .1 =1 I - �, Description : (1-6) C Vertical Reactions Load Combination 0 Only +D+L +D+S +D+0.750L+0.750S +0.60D L Only S Only File= S:UobsW81s181i1s1811020 -917 Pine Streefto 1812031181203 1F_enercalc tri�_0811020.ec( ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.17.2.2f Support notaltion : Far left is #1 Values in KIPS Support 1 Support 2 Support 3 0.968 2.123 0.564 4.731 0.593 4.065 0,383 5.536 0.581 1.274 -0.404 2.608 -0.375 1.942 File =S,.QobsW81s18111a1811020 - 917 Fine Stwilwo 1181201181203 T-enercalctrib-s'1811020.ed Steel Beam ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.1722E Description : (1 -7) A CODE REFERENCES Calculations per AISC 360-10, IBG 2015, ASCE 7-10 Load Combination Set: IBC 2015 Material Properties Analysis Method: Allowable Strength Design Fy : Steel Yield 50.0 ksi Beam Bracing: Beam is Fully Braced against lateral -torsional buckling Ei Modulus: 29,000.0 ksi Bending Axis: Major Axis Bencing DMAZ L161 S(O.15) Span 12.0 ft Span 6.0 ft WIN22 W12x22 Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Load for Span Number 1 Uniform Load : D = 0.0150, L = 0.040 ksf, Tributary Width = 9.0 ft, (FLOOR) Uniform Load: D = 0.020, L = 0,060, S = 0.0250 ksf, Tributary Width = 6.0 ft, (ROOF DECK) Point Load : W = 1.422, E = 4.339 k @ 0.0 ft Load(s) for Span Number 2 PointLoad: D=0.1070, L=0.04350, S=0.1780k@6.0ft,((1-5)) UniformLoad: D=0.020, L=0.060, S=0.0250ksf, Tributary Width= 15.0 ft, (ROOF DECK) PointLoad: D=0.1830, L=0.,W0, S=0.2280k(ZD_6.0ft,((1-3)) DESIGN SUMMARY Maximum Bending Stress Ratio Maximum Shear Stress Ratio 0.137 1 Section used for this span W12x22 Section used for this span W1 2x22 Ma: Applied 29.475 k-ft Va : Applied 8.761 k Mn / Omega: Allowable 73.104 k-ft Vn/Omega: Allowable 63.960 k Load Combinffi&D+0.750L+0.750S�+0.8925E, LL Comb Run (ILL) Load Combir(aBND+0.750L+0.75OS-0.8925E, LL Comb Run (1) Location of maximum on span 12.000ft Location of maximum on span 12.000 ft Span # where maximum occurs Span # 1 Span # where maximum occurs Span # 1 Maximum Deflection Max Downward Transient Deflection 0.253 in Ratio = 569 >=360 Max Upward Transient Deflection -0.119 in Ratio = 1,212 >=360 Max Downward Total Deflection 0.310 in Ratio= 465 >=180 Max Upward Total Deflection -0.070 in Ratio= 2059 >=180 Overall Maximum Deflections Load Combination Span Max."-" Defl Location in Span Load Combination Max. 'Y' Defl Location in Span +D+L 1 0.0767 5.760 +D+L -0.0699 7.440 +0+0.750L+0.75OS-0.5250E 2 0.3097 6.000 0.0000 7.440 Vertical Reactions Support notation : Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Support 3 Overall MAXimum 6.554 16.424 Overall MINimum :0.082 2.529 D Only -0.935 4.215 +D+L, LL Comb Run rQ .,0.711 11.852 +D+L, LL Comb Run (L*) 5.255 8.535 +D+L, LL Comb Run (U-) 3.609 16.172 +D+S 1.070 8.537 +D+0.750L+0.750S, LL Comb Run (*L) -0.198 13.184 +D+0.750L+0.750S, LL Comb Run (L) 4.276 10.696 +D+0.750L+0.750S, LL Comb Run (U.) 3.042 16.424 +D+0.60W 1.788 4.215 +D-0.60W 0.082 4.215 +D+0.70E 3.972 4.215 M ow �w 0 Steel Beam He -- �AJobs\sMs181`I\s181`I020-917 Pine Sbeetlwo 181203\181203 IF - enercalc trib_0811020.eci ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ve�:6.1722E W 1111 K.4 d -11, Description : (1 -7) A Vertical Reactions Support notabon Far left is #1 Values in KIPS Load Combination Support I Support 2 Support 3 +D-0.70E -2.102 4.215 +D+0.750L+0.750S+0.45OW, LL Comb R 0.441 13.184 +D+0.750L+0.750S+0.45OW, ILL. Comb R 4.916 10.696 +D+0.750L+0.750S+0A50W, LL Comb R 3.681 16.424 +D+0.750L+0.75OS-0.45OW, LL Comb Ri -0.838 13.184 +D+0.750L+0.75OS-0.45OW, LL Comb Ri 3.636 10.696 +D+0.750L+0.75OS-0.45OW,LL Comb Ri 2.402 16.424 +D+0.750L+0.750S+0.5250E, LL Comb F 2.080 13.184 +D+0.750L+0.750S+0.5250E, LL Comb F 6.554 10:696 +D+0.750L+0.750S+0.5250E, LL Comb F 5.320 .16.424 +D+0.750L+0.75OS-0.5250E, LL Comb R -2.476 13.184 +D+0.750L+0.75OS-0.5250E, ILL Comb R 1.998 10.696 +D+0.750L+0.75OS-0.5250E, LL Comb R 0.764 16.424 +0.60D+0,60W 1.414 2.529 +0.60D-0.60W -0.292 2.529 +0.60D+0.70E 3.598 2.529 +0.60D-0.70E -2.476 2.529 L Only, LL Comb Run (*L) -1.646 7.637 L Only, LL Comb Run (L*) 4.320 4.320 L Only, LL Comb Run (LL) 2.674 11.957 S Only 0.135 4.322 W Only 1 A22 0.000 -W -1.422 -0.000 E Only 4.339 E Only * -1.0 4.339 0 File= SAJobs\s'o8\s1811W811020 - 917 Pine StreetNwo 181203\181203 1F_enercalc trib_s1811020.ed Steel Beam ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.1722E . # : KW-06006655 Licensee: SOUND STRUCTURAL SOLUTIONS Description : (1-7) C CODE REFERENCES Calculations per AISC 360-10, 1 BC 2015, ASCE 7-10 Load Combination Set: IBC 2015 Material Properties Analysis Method: Allowable Strength Design Fy : Steel Yield 50.0 ksi Beam Bracing : Beam is Fully Braced against lateral -torsional buckling E: Modulus: 29,000.0 ksi Bending Axis : Major Axis Bending Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Load for Span Number 1 Uniform Load D = 0.0150 ksf, Tributary Width = 9.0 ft, (FLOOR) Uniform Load D = 0.020 ksf, Tributary Width = 6.0 ft, (ROOF DECK) Uniform Load D = 0,010 ksf, Tributary Width = 9.0 ft, (WALL) Uniform Load D = 0.020 ksf, Tributary Width = 6.0 ft, (ROOF) Uniform Load D = 0,020 ksf, Tributary Width = 9.0 ft, (ROOF DECK) Load(s) for Span Number 2 Point Load: D = 0.1070, L = 0.04350, S = 0.1780 k @ 6.0 ft, ((1-5)) Uniform Load : D = 0,020, L = 0.060, S = 0.0250 ksf, Tributary Width 15.0 ft, (ROOF DECK) Point Load: D = 0.1830, L = 0.5480, S = 0.2280 k @ 6.0 ft, ((1-3)) DESIGN SUMMARY Maximum Bending Stress Ratio 0,405: 1 Maximum Shear Stress Ratio = 0.138 : I Section used for this span W12x22 Section used for this span W1 2x22 Ma: Applied 29.591 k-ft Va : Applied 8.795 k Mn / Omega: Allowable 73.104 k-ft Vn/Omega: Allowable 63.960 k Load Combination +1.105D+0.750L+0.750S Load Combination +1.1050+0.750L+0.750S Location of maximum on span 16.500ft Location of maximum on span 16.500 ft Span # where maximum occurs Span # 1 Span # where maximum occurs Span # I Maximum Deflection Max Downward Transient Deflection 0.321 in Ratio = 449 >=360 Max Upward Transient Deflection -0. 132 in Ratio = 1,495 >=360 Max Downward Total Deflection 0. 193 in Ratio = 747 >=180 Max Upward Total Deflection -0. 160 in Ratio = 899 >=180 OR Pq Will OR fto OR wo Overall Maximum Deflections Load Combination Span Max. "-" Defi Location in Span Load Combination Max. "+" Defi Location in Span and D Only 1 0.1929 7.986 L Only -0.0798 14.124 L Only 2 0.3207 6.000 0.0000 14.124 Vertical Reactions Support notation Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Support 3 Overall MAXimum 4.889 15.645 Overall MlNimum -0.557 3.213 D Only 4.889 7.844 +D+L 3.692 15.032 +D+S 4.332 11.057 +D+0.750L+0.750S 3.573 15.645 +0.60D 2.933 4.706 L Only -1.197 7.188 S Only -0.557 3.213 PM No 'PIN Steel Beam Description : (1 -7) E File= &Qobs\s1ft18111s1811020-917 Pine Streedwo 18120181203 1 F_enercalctrilX_s 1811 020.ed ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver.6.17.2.2f CODE REFERENCES Calculations per AISC 360-10, IBC 2015, ASCE 7-10 Load Combination Set: IBC 2015 Material Properties Analysis Method: Allowable Strength Design Fy: Steel Yield: 50.0 ksi Beam Bracing: Beam is Fully Braced against lateral -torsional buckling E: Modulus: 29,000.0 ksi Bending Axis: Major Axis Bending D(O.3) L(J SAM) W>%, Span = 6.0 ft W12X22 Applied Loads Service loads entered. Load Factors will be applied for calculations, Beam self weight NOT internally calculated and added Wd Load(s) for Span Number 1 PointLoad: D=0.1070, L=0.04350, S=0.1780k@6.0ft,((1-5)) UniformLoad: D=0.020, L=0.060, S=0.0250ksf, Tributary Width= 15.0 ft, (ROOF DECK) PointLoad: D=0.1830, L=0.5480, S=0.2280k@6.Oft,((1-3)) DESIGN SUMMARY Maximum Bending Stress Ratio 0.405: 1 Maximum Shear Stress Ratio Section used for this span W12x22 Section used for this span Ma: Applied 29.591 k-ft Va: Applied Mn / Omega: Allowable 73.104 k-ft Vn/Onnega: Allowable Load Combination +1.105D+0.750L+0.750S Load Combination Location of maximum on span 0.000ft Location of maximum on span Span # where maximum occurs Span # 1 Span # where maximum occurs Maximum Deflection Max Downward Transient Deflection Max Upward Transient Deflection Max Downward Total Deflection Max Upward Total Deflection ; rp ind goo Overall Maximum Deflections 0.072 in Ratio= 2,005 >=360 0.000 in Ratio= 0 <360 0. 106 in Ratio = 1358 >=180 0.000 in Ratio= 0 <180 0.138 W1 2x22 8.795 k 63.960 k +1. 1 05D+0.750L+0.750S 0.000 It Span # I Load Combination Span Max. "-" Dell Location in Span Load Combination Max."+" Defi Location in Span +D+0.750L+0.750S 1 0.1061 6.000 0.0000 0.000 Vertical Reactions Support notation Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Overall MAXimum 8.576 Overall MiNimum 1.254 D Only 2.090 +D+L 8.082 +D+S 4.746 +D+0.750L+0.750S 8.576 +0.60D 1.254 L Only 5.992 S Only 2.656 File= SAJobs\slffisi811ks181l1020-9117 Pine Streeftwo 181203\181203 T enercalctrib s1811020,ec( steel Beam ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.17.2.2f Lic. # : KW-06006655 Licensee: SOUND STRUCTURAL SOLUTIONS Description : (1 -8) A CODE REFERENCES Calculations per AISC 360-10, IBC 2015, ASCE 7-10 Load Combination Set: IBC 2015 Material Properties Analysis Method: Allowable Strength Design Beam Bracing: Beam is Fully Braced against lateral -torsional buckling Bending Axis: Major Axis Bending Fy : Steel Yield 50.0 ksi E: Modulus: 29,000.0 ksi Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Load for Span Number 1 Uniform Load D = 0.0150, L = 0.040 ksf, Tributary Width = 9.0 ft, (FLOOR) Uniform Load D = 0.0 10 ksf, Tributary Width = 9.0 ft, (WALL) Load(s) for Span Number 2 Point Load : D = 0.0380, L = 0.1130, S = 0.0470 k @ 6.0 ft, ((1-1)) Uniform Load : D = 0.020, L = 0.060, S = 0.0250 ksf, Tributary Width = 11.0 ft, (ROOF DECK) Point Load: D = 0.1830, L = 0.5480, S = 0.2280 k @ 6.0 ft, ((1-3)) DESIGN SUMMARY �011111111 Maximum Bending Stress Ratio 0.310: 1 Maximum Shear Stress Ratio 0.103 - I Section used for this span W1 2x22 Section used for this span W12x22' Ma: Applied 22.676 k-ft Va: Applied 6.612 k Mn / Omega: Allowable 73.104 k-ft Vn/Omega: Allowable 63.960 k Load Combination +1.105D+0.750L+0.750S Load Combination +1.105D+0.750L+0.750S Location of maximum on span 16.500ft Location of maximum on span 16.500 ft Span # where maximum occurs Span # 1 Span # where maximum occurs Span # 1 Maximum Deflection Max Downward Transient Deflection 0.108 in Ratio = 1,337 >=360 Max Upward Transient Deflection -0.044 in Ratio = 4;473 >=360 Max Downward Total Deflection 0.149 in Ratio= 969 >=180 Max Upward Total Deflection -0.010 in Ratio = 14049 >=180 Overall Maximum Deflections Load Combination Span Max . ..... Defl Location in Span Load Combination Max. "+" Defi Location in Span +D+L +D+0.750L+0.750S Vertical Reactions Load Combination 1 2 Support I 0.0830 6.864 S Only 0.1487 6.000 Support notation Far left is #1 Support 2 Support 3 -0.0395 12.012 PE 0.0000 12.012 wo Values in KIPS Overall MAXimum 3.546 12.269 Overall MINimum -0.400 2.231 D Only 1.536 3.718 +D+L 3.546 12.269 +D+S 1.136 6.043 PM +D+0.750L+0.750S 2.743 11.875 +0.60D D.922 2.231 INd L Only 2.010 8.551 S Only -0.400 2.325 00 bw W aw I pl� Pq Steel Beam L iTff, MF,'M, W.d Description (1 -8) C 0 woo CODE REFERENCES Calculations per AISC 360-10, 113C 2015, ASCE 7-10 Load Combination Set : 113C 2015 Material Properties File = S.,\JobsWMs181%1811020 - 917 Pine Streellwo 181203�`181203 1F-enercalc tdb_s1811020.ec1 ENERCALC, INC. 1983-2017, Build:6.17.2.28. Ver.6.17.2.' 2E Analysis Method: Allowable Strength Design Fy : Steel Yield: 50.0 ksi Beam Bracing: Beam is Fully Braced against lateral -torsional buckling E: Modulus: 29,000.0 ksi Bending Axis: Major Axis Bending Q(0.18) D(V9) Q(�35) D(O.22) L( S(O.27q(0.088) L(O 48) S(O.249) 30 * Span 6.0 ft Span = 16.5D ft W12x22 W12x22 Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Load for Span Number 1 Uniform Load: D = 0.0150 ksf, Tributary Width = 9.0 ft, (FLOOR) Uniform Load: D = 0.010 ksf, Tributary Width = 9.0 ft, (WALL) Uniform Load: D = 0.020 ksf, Tributary Width = 9.0 ft, (ROOF DECK) Load(s) for Span Number 2 Point Load: D = 0.0380, L = 0,1130, S = 0.0470 k @ 6.0 ft, ((1-1)) Uniform Load : D = 0.020, L = 0.060, S = 0.0250 ksf, Tributary Width 11.0 ft, (ROOF DECK) Point Load: D = 0.1830, L = 0.5480, S = 0.2280 k @ 6.0 ft, ((1-3)) DESIGN SUMMARY nmff��� Maximum Bending Stress Ratio 0.310: 1 Maximum Shear Stress Ratio = Section used for this span W1 2x22 Section used for this span Ma: Applied 22.676 k-ft Va : Applied Mn / Omega: Allowable 73.104 k-ft Vn/Onnega: Allowable Load Combination +1.1 05D+0.750L+0.750S Load Combination Location of maximum on span 16.500 ft Location of maximum on span Span # where maximum occurs Span # 1 Span # where maximum occurs Maximum Deflection Max Downward Transient Deflection 0.259 in Ratio= 556 >=360 Max Upward Transient Deflection -0.106 in Ratio= 1,863 ­360 Max Downward Total Deflection 0.187 in Ratio= 769 >=180 Max Upward Total Deflection -0.087 in Ratio= 1646 >=180 Overall Maximum Deflections 0.103 W1 2x22 6.612 k 63.960 k +1. 1 05D+0.750L+0.750S 16.500 ft Span # 1 Load Combination Span Max.%" Defl Location in Span Load Combination Max. 'Y' Defi Location in Span D Only 1 0-1159_ 7.986 L Only _0-1F55_ 10.230 L Only 2 0.2586 6.000 0.0000 10.230 Vertical Reactions Support notation Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Support 3 Overall MAXimum 3.021 11.132 Overall MINimum -0.400 2.325 D Only 3.021 5.203 +D+L 2.061 10.784 +D+S 2.621 7.528 +D+0.750L+0.750S 2.001 11.132 +0.60D 1.813 3.122 L Only -0.960 5.581 S Only -0.400 2.325 go File =S:Uobs\s18\s1811\s1811020-917 Pine Streeftwo 181203\181203 1F—enercalc trib_s1811020.ec( Steel Beam ENERGALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.17.2.2f . -ic. #: KW-06006655 Licensee: SOUND STRUCTURAL SOLUTIONt Description : (1-8) E CODE REFERENCES Calculations per AISC 360-10, 1 3C 2015, ASCE 7-10 Load Combination Set: IBC 2015 Material Properties, Analysis Method: Allowable Strength Design Fy : Steel Yield: 50.0 ksi Beam Bracing: Beam is Fully Braced against lateral -torsional buckling E: Modulus: 29,000.0 ksi Bending Axis: Major Axis Bending W12x22 Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Load(s) for Span Number 1 PointLoad: D=0.0380, L=0.1130, S=0.0470kP_6.0ft,((1-1)) UniformLoad: D=0.020, L=0.060, S=0.0250ksf, Tributary Width= 11.0 ft, (ROOF DECK) PointLoad: D=0.1830, L=0.5480, S=0.2280k@6.0ft,((1-3)) DESIGN SUMMARY Maximum Bending Stress Ratio 0.310: 1 Maximum Shear Stress Ratio 0.103 : 1 Section used for this span W1 2x22 Section used for this span W1 2x22 Ma: Applied 22.676 k-ft Va: Applied 6.612 k Min / Omega: Allowable 73.104 k-ft Vn/Ornega: Allowable 63.960 k Load Combination +1.105D+0.750L+0.750S Load Combination +1.105D+0.750L+0.750S Location of maximum on span 0.000ft Location of maximum on span 0.000 ft Span # where maximum occurs Span # 1 Span # where maximum occurs Span # 1 Maximum Deflection Max Downward Transient Deflection 0.059 in Ratio = 2,444 >=360 Max Upward Transient Deflection 0.000 in Ratio = 0 <360 Max Downward Total Deflection 0.082 in Ratio = 175" >=180 Max Upward Total Deflection 0.000 in Ratio = 6 1180 Overall Maximum Deflections Load Combination Span Max. "-" Defl Location in Span Load Combination Max. 'Y' Defl Location in Span +D+0.750L+0.750S Vertical Reactions- 1 0.0822 Load Combination -_ - Support 1 Support 2 Overall MAXimum 6.451 Overall MINimum 0.925 0 Only 4.541 +D+L 6.162 +D+S 3.466 +D+0.750L+0.750S 6.451 +0.60D 0.925 L Only 4.621 S Only 1.925 6.000 0.0000 0.000 Support notation : Far left is #1 Values in KIPS Wood Beam File= S:kJobs\,s18\s1811\s1811020 - 917 Pine Streefto 181203\181203 1F—enercalc trib — s1811020.e,( ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.17.22E 1-ic. #: KW-06006655 Licensee - SOUND STRUCTURML —SOUMOM Description : (1 -9) A CODE REFERENCES Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10 Load Combination Set: IBC 2015 Material Properties Analysis Method: Allowable Stress Design Fb - Tension 2,325.0 psi E Modulus of Elasticity Load Combination IBC 2015 Fb - Compr 2,325.0 psi Ebend-xx 1,550.0ksi Fc - Prll 2,170.0 psi Eminbend - xx 787.82 ksi Wood Species Trus Joist Fc - Perp 900.0 psi Wood Grade TimberStrand LSL 1.55E Fv 310. 0 psi Ft 1,070.0 psi Density 44.990 pcf Beam Bracing Beam is Fully Braced against lateral -torsional buckling MOM) U16) S(O.025) D(V9) D(O.169) S(U82) M0.015) L(O.04) D(O.021 S(0,025) 3.5x1 1.875 3.5xi 1.875 Span = 9.50 ft Span = 2.0 ft Applied Loads Service loads entered. Load Factors will be applied for calculations. Load for Span Number I Uniform Load : D = 0.0150, L = 0.040 , Tributary Width = 1.0 ft, (FLOOR) Uniform Load: D = 0.010 ksf, Tributary Width = 9.0 ft, (WALL) Uniform Load: D = 0.020, L = 0.060, S = 0.0250 , Tributary Width = 1.0 ft, (ROOF DECK) Load for Span Number 2 Point Load: D = 0.1690, S = 0.2820 k @ 2.0 ft, ((1-4)) Uniform Load : D = 0.020, S = 0.0250, Tributary Width = 1.0 ft, (ROOF) Maximum Bending Stress Ratio PO Section used for this span flo : Actual FB : Allowable Load Combination Location of maximum on span Span # where maximum occurs Maximum Deflection Max Downward Transient Deflection PIN Max Upward Transient Deflection Max Downward Total Deflection Max Upward Total Deflection Overall Maximum Deflections SEW 6. 0.14111 Maximum Shear Stress Ratio 0.129 : I 3.5xl 1.875 Section used for this span 3.5xl 1.875 343.23 psi fv : Actual 40.01 psi 2,325.00 psi Fv: Allowable 310.00 psi +D+L Load Combination +D+L 4.564ft Location of maximum on span 9.500 fl, Span # 1 Span # where maximum occurs Span # 1 0.024 in Ratio= 4667 >=360 -0.016 in Ratio= 2942 >=360 0.050 in Ratio = 2277 ­240. -0.030 in Ratio = 1592 ­240. Load Combination Span Max. "-" Defl Location in Span Load Combination Max. 'Y' Defl Location in 'Span +D+L 1 0.0501 4.723 0.0000 0.000 2 0.0000 4.723 +D+L -0.0301 2.000 Vertical Reactions Support notation : Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Support 3 Overall MAXimum 1.029 1.585 Overall MINinnum 0.054 0.475 File= S:UobsW81s18Ms1811020 - 917 Pine Streetwo 1812031181203 1F—enercalc trib—M`11020,ed Wood Beam ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.17.2.2E 1111MI'MATE11:91 I "M 1111111c,161 Rob i M 0 Description : (1 -9) A Vertical Reactions Load Combination D Only +D+L +D+S +D+0.750L+0.750S +0.60D L Only S Only Support notation : Far left is #1 Supportl Support 2 Support 3 0.554 0.843 1.029 1.318 0.608 1.358 0.951 1.585 0.332 0.506 0.475 0.475 0.054 0.515 Values in KIPS P@ Pill I Ifflood Beam File= &WoWs'18\0811\0811020 - 9W Pine Street\wo 181203\181203 I F—enercalc trib—s'1811020ed ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.117.2.21 IlLic. # : KW-06006655 Licensee: SOUND STRUCTURAL SOLVEL- Description (1 -9) B OR CODE REFERENCES I ow Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10 Load Combination Set: IBC 2015 Material Properties Analysis Method: Allowable Stress Design Fb - Tension 2,325.0 psi E Modulus of Elasticity Load Combination IBC 2015 Fb - Compr 2,325.0 psi Ebend-xx 1,550.0ksi Fc - Prll 2,170.0 psi Eminbend - xx 787.82 ksi Wood Species Trus Joist Fc - Perp 900.0 psi Wood Grade TimberStrand LSL 1.55E Fv 310. 0 psi Ft 1,070.0 psi Density 44.990 pcf Beam Bracing Beam is Fully Braced against lateral -torsional buckling PR low PM D(O.02) L( i 6)S(O.025) DV) D(O. 1 169) 3.5xl 1.875 3.5xll.875 Span = 9.50 ft Span = 2.0 ft Applied Loads Service loads entered. Load Factors will be applied for calculations, Load for Span Number 1 Uniform Load D = 0.0150, L = 0.040, Tributary Width = 1.0 ft, (FLOOR) Uniform Load D = 0.010 ksf, Tributary Width = 9.0 ft, (WALL) Uniform Load D = 0.020, L = 0.060, S = 0.0250 , Tributary Width = 1.0 ft, (ROOF DECK) Load for Span Number 2 Point Load : D = 0.1690 k @_ 2.0 ft, ((1-4)) Uniform Load : D = 0.020, Tributary Width = 1.0 ft, (ROOF) Maximum Bending Stress Ratio Section used for this span fb : Actual FIB: Allowable Load Combination Location of maximum on span Span # where maximum occurs Maximum Deflection Max Downward Transient Deflection Max Upward Transient Deflection Max Downward Total Deflection Max Upward Total Deflection OA4a 1 Maximum Shear Stress Ratio 0.129 : 1 3.5xl 1.875 Section used for this span 3.Sxl 1.875 343.23 psi fv : Actual 40.01 psi 2,325.00 psi Fv: Allowable 310.00 psi +D+L Load Combination +D+L 4.564ft Location of maximum on span 9.500 ft Span # 1 Span # where maximum occurs Span # 1 0.024 in Ratio= 4667 ­360 -0.016 in Ratio= 2942 >=360 0.050 in Ratio= 2277 >=240. -0.030 in Ratio= 1592 >=240. Overall Maximum Deflections Load Combination Span Max. "-" Defl Location in Span Load Combination Max. 'Y' Defi Location in Span +D+L 1 0.0501 4.723 0.0000 0.0c.0 2 0.0000 4.723 +D+L -0.0301 2.000 Vertical Reactions Support notation : Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Support 3 Overall MAXimum 1.029 1.318 Overall MINimum 0.119 0.119 Fill 1 6.W Wood Beam File = S:Uobs's Iffisl8l %11811020 - 917 Pine Streeftwo 118120MM03 IF_enercalc trib_s1811020.ec( ENERCALC, INC. 1983-2017, Build:6.17.2.28. Ver:6.17.2,2f Description : (1 -9) B Vertical Reactions Support notation : Far left is #1 Values in KIPS Load Combination Suppoql Support 2 Support 3 D Only 0.554 0.843 +D+L 1.029 1.318 +D+S 0.673 0.961 +D+0.750L+0.750S 0.999 1.288 +0.60D 0.332 0,506 L Only 0.475 0.475 S Only 0.119 0.119 Wood Beam File= S.\Jobs\s18\s181%11811020 - 917 Pine El #: KW-06006655 Licen Description : (1 -9) C CODE REFERENCES Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10 Load Combination Set: IBC 2015 Material Properties Analysis Method: Allowable Stress Design Fb - Tension 2,325.0 psi Load Combination JBC 2015 Fb - Compr 2,325.0 psi Fc - Pdl 2,170.0 psi Wood Species Trus Joist Fc - Perp 900.0 psi Wood Grade TimberStrand LSL 1.55E Fv 310.0 psi Ft 1,070.0 psi Beam Bracing Beam is Fully Braced against lateral -torsional buckling 1812031181203 11'_enercalc trlb_s1811020.ec( INC. 1983-2017, Build:6.17.2.28, Ver:6.17.2.2E E: Modulus of Elasticity Ebend-xx 1,550.0 ksi Eminbend - xx 787.82 ksi Density 44.990 pcf D( 2) D( 9) D(O.169) I S(0,282) 3.Sxl 1.875 3.5X1 1.875 Span = 9.50 ft Span = 2.0 ft Applied Loads Load for Span Number 1 Uniform Load: D = 0.0150, Tributary Width = 1.0 ft, (FLOOR) Uniform Load : D = 0.010 ksf, Tributary Width = 9.0 ft, (WALL) Uniform Load: D = 0.020, Tributary Width = 1.0 ft, (ROOF DECK) Load for Span Number 2 PointLoad: D=0.1690, S=0.2820k@_2.Oft,((1-4)) UniformLoad: D=0.020, S=0.0250, Tributary Width= 1.0ft, (ROOF) DESIGN SUMMARY Service loads entered. Load Factors will be applied for calculations. r �Maximurn Bending Stress Ratio 0�08e. 1 Maximum Shear Stress Ratio 0.082 : 1 Section used for this span 3.5xl 1.875 Section used for this span 3.Sxl 1.875 flo : Actual 179.06psi fv : Actual 22.86 psi FB: Allowable 2,092.50 psi Fv: Allowable 279.00 psi Load Combination D Only Load Combination D Only Location of maximum on span 4.458ft Location of maximum on span 9.500 It Span # where maximum occurs Span # 1 Span # where maximum occurs Span # I Maximum Deflection Max Downward Transient Deflection 0.011 in Ratio 4486 >=360 Max Upward Transient Deflection -0.008 in Ratio= 13948 >=360 Max Downward Total Deflection 0.026 in Ratio= 4444 >=240. Max Upward Total Deflection -0.014 in Ratio= 3476 >=240. Overall Maximum Deflections Load Combination Span Max. Defi Location in Span Load Combination Max. 'Y' Def] Location in Span D Only 1 0.0256 4.670 0.0000 0.000 2 0.0000 4.670 D Only -0.0138 2.000 Vertical Reactions Support notation : Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Support 3 Overall MAXimum 0.554 1.239 Overall MINimum -0.065 0.397 am so Wood Beam Description (1 -9) C Vertical Reactions Load Combination D Only +D+S +D+0.750S +0.601) S Only He= S-.Uobs1s181s18111s1811020-917 Fine Streeftwo 18120181203 lFjnercalc bib — s1811020.ed I ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.17.2.2E Licensee: SOUND STRUCTURAL SOLUTIONS Support notation : Far left is #1 Values in KIPS Support 1 Support 2 Support 3 0.554 0.843 0.489 1.239 0.505 1.140 0.332 0.506 -0.065 0.397 go also Wood Beam File= SAJobs\sWs1811\s1811020 -917 Pine Street\wo 181203\181203 11`�enercalc trb_s1811020.ec( ENERCALC, INC. 1983-2017, Build:6.17.2.28, Verl iLic. #: KW-06006655 Description : (1 -9) E CODE REFERENCES Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10 Load Combination Set: IBC 2015 Material Properties Analysis Method: Allowable Stress Design Fb - Tension Load Combination JBC 2015 Fb - Compr Fc - Pr1l Wood Species Trus Joist Fc - Perp Wood Grade TimberStrand LSL 1.55E Fv Ft Beam Bracing Beam is Fully Braced against lateral -torsional buckling D(O.169 S(O.282) D(O.021 S(0.02Q —4 3.5xl 1.875 Span = 2.0 ft 2,325.0 psi E: Modulus of Elasticity 2,325.0 psi Ebend-xx 1,550.0 ksi 2,170.0 psi Eminbend - xx 787.82 ksi 900.0 psi 310.0 psi 1,070.0 psi Density 44.990 pcf Applied Loads Service loads entered. Load Factors will be applied for calculatiors. PointLoad: D=0.1690, S=0.2820k@2.0ft,((1-4)) Uniform Load : D = 0.020, S = 0.0250 , Tributary Width 1.0 ft, (ROOF) DESIGN SUMMARY �Maximum Bending Stress Ratio 0.05411 Maximum Shear Stress Ratio Section used for this span 3.5xl 1.875 Section used for this span fb : Actual 144.71 psi fv : Actual FB: Allowable 2,673.75 psi Fv: Allowable Load Combination +D+S Load Combination Location of maximum on span 0.000ft Location of maximum on span Span # where maximum occurs Span # 1 Span # where maximum occurs Maximum Deflection Max Downward Transient Deflection 0.002 in Ratio= 26292 ­360 Max Upward Transient Deflection 0.000 in Ratio 0 <360 1 Max Downward Total Deflection 0.003 in Ratio= 16312 >=240. Max Upward Total Deflection 1 0.000 in Ratio= 0 <240.0 Overall Maximum Deflections 0.055 : 1 3.5xl 1.875 19.52 psi 356.50 psi +D+S 0.000 ft Span # 1 Load Combination Span Max. "-" Defl Location in Span Load Combination Max. 'Y' Defi Location in Span +D+S 1 0.0029 2.000 0.0000 0.000 Vertical Reactions Support notation : Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Overall MAXimum 0.541 Overall MINimum 0.125 1) Only 0.209 -FD+S 0.541 +D+0.750S 0.458 +0.60D 0.125 S Only 0.332 MCI No OR 00 Wood Beam File= SAJoWsiffis'1811\0811020 - 917 Pine Streeftwo 181203\181203 1F — enercalc trib—sl 811020.eci ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.17.2.2E Description (1-10) CODE REFERENCES PSI Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10 Load Combination Set: IBC 2015 Material Properties Analysis Method: Allowable Stress lDesign Fb - Tension 2,325.0 psi E: Modulus of Elasticity Load Combination IBC 2015 Fb - Compr 2,325.0 psi Ebend-xx 1,550.0 ksi Fc - Prll 2,170.0 psi Eminbend - xx 787.82 ksi Wood Species Trus Joist Fc - Perp Fv 900.0 psi 310.0 psi Wood Grade TimberStrand LSL 1.55E Ft 1,070.0 psi Density 44.990 pcf Beam Bracing Beam is Fully Braced against lateral -torsional buckling D( V 9) D(O.03) U0.08) 1.75x14 Span = 11.50 ft Applied Loads Service loads entered. Load Factors will be applied for calculations. Uniform Load D = 0.0150, L = 0.040 ksf, Tributary Width = 2.0 ft, (FLOOR) Uniform Load D = 0.010 ksf, Tributary Width 9.0 ft, (WALL) DESIGN SUMMARY [Maximum Bending Stress Ratio 0.30a 1 Maximum Shear Stress Ratio 0.227 : 1 Section used for this span 1.75xl 4 Section used for this span 1.75x14 fto : Actual 694.02 psi fv : Actual 70.41 psi FB: Allowable 2,292.26 psi Fv: Allowable 310.00 psi Load Combination +D+L Load Combination +D+L Location of maximum on span 5,750ft Location of maximum on span 0.000ft Span # where maximum occurs Span # 1 Span #where maximum occurs Span # I Maximum Deflection max Downward Transient Deflection 0.051 in Ratio = 2703 >=360 Max Upward Transient Deflection 0.000 in Ratio = 0 <360 Max Downward Total Deflection 0.128 in Ratio= 1081 -240. Max Upward Total Deflection 0.000 in Ratio 0 <240.0 Overall Maximum Deflections Load Combination Span Max. Defi Location in Span Load Combination Max. 'Y' Defi Location in Span +D+L 1 0,1276 5.792 0.0000 0.000 Vertical Reactions Support notation : Far left is #1 Values in KIPS Load Combination Support I Support 2 Overall MAXimum 1.150 1.150 Overall MINimurn 0.414 0,414 D Only 0.690 0.690 +D+L 1.150 1.150 +D+0.750L 1.035 1.035 +0.60D OA14 0.414 L Only 0.460 0.460 PW bw W No ,on ow Wood Beam File= SAJobsksiffis'1131 1\0811020 - 917 Pine Streeftwo 181203\181203 I F_enercalc trl1b_s1811020.ec1 ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver.6.1722E tric. #. KW-06006655 Licensee ' SOUND STRUCTURAL SOLU- Description : (1-11) CODE REFERENCES Calculations per NDS 2015, 1 BC 2015, CBC 2016, ASCE 7-10 Load Combination Set: IBC 2015 -Material Properties Analysis Method: Allowable Stress Design Fb - Tension 2,325.0 psi E: Modulus of Elasticity Load Combination IBC 2015 Fb - Compr 2,325.0 psi Ebend-xx 1,550.Oksi Fc - Prll 2,170. 0 psi Eminbend - xx 787.82 ksi Wood Species Trus Joist Fc - Perp 900.0 psi Wood Grade TimberStrand LSL 1.55E Fv 310. 0 psi Ft 1,070.0 psi Density 44.990 pef Beam Bracing Beam is Fully Braced against lateral -torsional buckling D(0, I V0,44) 1.75x14 Span = 6.0 ft Applied Loads Service loads entered. Load Factors will be applied for calculations. Uniform Load : D = 0.0150, L = 0.040 ksf, Tributary Width = 11.0 ft, (FLOOR) DESIGN SUMMARY 1 6 .Maximum Bending Stress Ratio 0.24R. 1 Maximum Shear Stress Ratio 0358 : 1 Section used for this span 1.75x14 Section used for this span 1.75x14 fb : Actual 571.49 psi fv : Actual 111.12 psi FB: Allowable 2,292.26 psi Fv: Allowable 310.00 psi 1 Load Combination +D+L Load Combination +D+L 1 Location of maximum on span 3.000ft Location of maximum on span 0.000ft Span # where maximum occurs Span # 1 Span # where maximum occurs Span # 1 Maximum Deflection Max Downward Transient Deflection 0.021 in Ratio= 3460 >=360 Max Upward Transient Deflection 0.000 in Ratio= 0 <360 Max Downward Total Deflection 0.029 in Ratio= 2516 >=240, Max Upward Total Deflection 0.000 in Ratio= 0 <240.0 Overall Maximum Deflections Load Combination Span Max. Defl Location in Span Load Combination Max. 'Y' Defl Location in Span +D+L 1 0.0286 3.022 0.0000 0.000 Vertical Reactions Support notation : Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Overall MAXimum 1.815 1.815 Overall MINimum 0.297 0.297 1) Only 0.495 0.495 +D+L 1.815 1.815 +D+0.750L 1.485 1.485 +0.60D 0.297 0.297 L Only 1.320 1.320 Wood Beam File= S:\Jobs\s18\s1811\s1811020 -917 Pine Streelkwo 1811201811203 1F_pnercalc tr1b_s1811020.ed ENERCALC, INC. 1983-20,17, Build:6.17.2.28, Ver:6.1722E Lic. #: KW-06006655 Licensee: SOUND STRUCTURAL SOLUTIONS Description : (1 -11) CODE REFERENCES Calculations per NDS 2015, 1 BC 2015, CBC 2016, ASCE 7-10 Load Combination Set: IBC 2015 Material Properties Analysis Method: Allowable Stress Design Fb - Tension 900 psi E: Modulus of Elasticity Load Combination IBC 2015 Fb - Compr 900 psi Ebend-xx 1600ksi Fc - Pril 1350 psi Eminbend - xx 580 ksi Wood Species Douglas Fir - Larch Fe - Perp 625 psi Wood Grade No.2 Fv 180 psi Ft 575 psi Density 31.2pcf Beam Bracing Beam is Fully Braced against lateral -torsional buckling D(0.11L(O.44) 2-24 Span = 3.0 ft Applied Loads Service loads entered. Load Factors will be applied for calculations. Uniform Load: D = 0.0150, L = 0.040 ksf, Tributary Width = 11.0 ft, (FLOOR) Maximum Bending Stress Ratio 0.4621 Maximum Shear Stress Ratio 0.458 : 1 Section used for this span 2-2x6 Section used for this span 2-2x6 flo : Actual 540.00psi fv: Actual 82.50 psi FB: Allowable 1, 170.00 psi Fv: Allowable 180.00 psi Load Combination +D+L Load Combination +D+L Location of maximum on span 1.500ft Location of maximum on span 0.000 ft Span # where maximum occurs Span # 1 Span # where maximum occurs Span # 1 Maximum Deflection Max Downward Transient Deflection 0.012 in Ratio= 2970 >=360 Max Upward Transient Deflection 0.000 in Ratio= 0 <360 Max Downward Total Deflection 0.017 in Ratio= 2160 ­240. Max Upward Total Deflection 0.000 in Ratio= 0 <240.0 Overall Maximum Deflections Load Combination Span Max. %" Defi Location in Span Load Combination +D+L Reactions 1 0.0167 1.511 Support notation : Far left is #1 --Vertical Load Combination Suppoql Support 2 Overall MAXimum 0.908 0.908 Overall MINimum 0.149 0.149 D Only 0.248 0.248 +D+L 0.908 0.908 +D+0.750L 0.743 0.743 +0.60D 0.149 0.149 L Only 0.660 0.660 Max. 'Y' Defl Location in Span 0.0000 0.000 Values in KIPS File= SMobs\s1ffis1811\s1811020 -917 Pine Streefto 181203\181203 I F—enercalc trib_s181102D.ed Wood Beam 'ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver6.17.22E IlLic. #. KW-06006655 Lica Description : (1-12) CODE REFERENCES Calculations per NDS 2015, 1 BC 2015, CBC 2016, ASCE 7-10 Load Combination Set: IBC 2015 Material Properties Analysis Method: Allowable Stress Design Fb - Tension 2,325.0 psi Load Combination JBC 2015 Fb - Compr 2,325.0 psi Fc - Prll 2,170.0 psi Wood Species Trus Joist Fc - Perp 900.0 psi Wood Grade TimberStrand LSL 1.55E Fv 310.0 psi Ft 1,070.0 psi Beam Bracing Beam is Fully Braced against lateral -torsional buckling D(O.01 5) S(0,025) 1.75xl 1.875 Span = 10.50 ft E: Modulus of Elasticity Ebend-xx 1,550.0 ksi Eminbend - xx 787.82 ksi Density 44.990 pcf Applied Loads Service loads entered. Load Factors will be applied for calculations. Uniform Load : D = 0.0150, S = 0.0250, Tributary Width = 1.0 ft, (ROOF) UkWUN bUMMANY Maximum Bending Stress Ratio 0.06Q. 1 Maximum Shear Stress Ratio 0.043 : 1 Section used for this span 1.75xl 1.875 Section used for this span 1.75xll.875 fb : Actual 160.83 psi fv : Actual 15.16 psi FB: Allowable 2,673.75 psi Fv: Allowable 356,50 psi Load Combination +D+S Load Combination +D+S Location of maximum on span 5.250ft Location of maximum on span 0.000 ft Span # where maximum occurs Span # 1 Span # where maximum occurs Span # 1 Maximum Deflection Max Downward Transient Deflection 0.018 in Ratio 6935 >=360 Max Upward Transient Deflection 0.000 in Ratio= 0 <360 Max Downward Total Deflection 0.029 in Ratio = 4334 >=240. Max Upward Total Deflection 0.000 in Ratio= 0 <240.0 Overall Maximum Deflections Load Combination Span Max. "-" Defl Location in Span Load Combination Max. 'T' Defl Location in Span +D+S 1 0.0291 5.288 0.0000 0.000 Vertical Reactions Support notation : Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Overall MAXlmum 0.210 0.210 Overall MINimum 0.047 0.047 D Only 0.079 0.079 +D+S 0.210 0.210 +D+0.750S 0.177 0.177 +0.60D 0.047 0.047 S Only 0.131 0.131 File= S.Uobs\s1ffis1811\s1811020 - 917 Pine Streeftwo 181203\181203 1F enercalctrib s181111020.ed Wood Beam ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.17.2.2f Lic. # : KW-06006655 Licensee: SOUND STRUCTURAL SOLUTIONS Description : (1-13) A CODE REFERENCES Calculations per NDS 2015, 1 BC 2015, CBC 2016, ASCE 7-10 Load Combination Set: IBC 2015 Material Properties Analysis Method: Allowable Stress Design Fb - Tension 2,325.0 psi E: Modulus of Elasticity Load Combination IBC 2015 Fb - Compir 2,325.0 psi Ebend-xx 1,550.0 ksi Fc - PrIl 2,170.0 psi Eminbend - xx 787.82 ksi Wood Species Trus Joist Fc - Perp 900.0 psi Wood Grade TimberStrand LSL 1,55E Fv 310.0 psi Ft 1,070.0 psi Density 44.990 pef Beam Bracing Beam is Fully Braced against lateral -torsional buckling D(O.12 V (0.15) D(O.0 i S(O.1) ___+ 1.75xl 1.875 1.75X11.875 Span = 5.50 ft Span = 3.250 ft Appi ie-d.- Loads Service loads entered. Load Factors will be applied for calculations. Load for Span Number 1 Uniform Load : D = 0.020, S = 0.0250 ksf, Tributary Width = 6.0 ft, (ROOF) Load for Span Number 2 Uniform Load : D = 0.020, S = 0.0250 ksf, Tributary Width = 4.0 ft, (ROOF) DESIGN SUMMARY Maximurn Bending Stress Ratio 0.1041 Maximum Shear Stress Ratio 0,185 : 1 Section used for this span 1.75xll.875 Section used for this span 1.75xl 1.875 flo : Actual 277.36 psi fv : Actual 66.07 psi FB: Allowable 2,673.75 psi Fv: Allowable 356.50 psi Load Combination +D+S Load Combination +D+S Location of maximum on span 5.500ft Location of maximum on span 5.500 ft Span # where maximum occurs Span # I Span # where maximum occurs Span # I Maximum Deflection Max Downward Transient Deflection 0.005 in Ratio= 14772 >=360 Max Upward Transient Deflection 0.000 in Ratio= 0 <360 Max Downward Total Deflection 0.010 in Ratio = 8206 >=240. Max Upward Total Deflection -0.000 in Ratio = 376462 >=240. Overall Maximum Deflections Load Combination Span Max."-" Defl Location in Span Load Combination Max. "+" Defl Location in Span +D+S 1 0.0067 2.397 0.0000 0.000 +D+S 2 0.0095 3.250 +D+S -0.0000 0.145 Vertical Reactions Support notation : Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Support 3 Overall MAXinnurn 0.570 1.500 Overall MINimum 0.152 0.400 D Only 0.253 0.667 +D+S 0.570 1.500 +D+0.750S 0.491 1.292 Wood Beam Description (1-13) A Vertical Reactions Load Combination +0.60D S Only ; I'm PIN File= S:\Jobs\s1Ms1811\s1811020 -917 Pine Street1wo 18120181203 1F—enercalc tril�—Ml 1020.e(i ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.17.2.2E Support notation : Far left is #1 Values in KIPS Supportl Support 2 Support 3 0.152 0,400 0.316 0.834 File= S:Wobs\s18\s1811\s1811020-917 Pine Stredwo 181203\181203 I F_enercaIctrib_s1811020.ec1 Nood Beam ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.17.2.2E . —ic. #: KW-06006655 Licensee. SOUND STRUCTURAL SOLUTION." Description : (1-13) C CODE REFERENCES Calculations per INDS 2015, IBC 2015, CBC 2016, ASCE 7-10 Load Combination Set: IBC 2015 Material Properties Analysis Method: Allowable Stress Design Fb - Tension 2,325.0 psi E: Modulus of Elasticity Load Combination IBC 2015 Fb - Compr 2,325.0 psi Ebend-xx 1,550.Oksi Fe - PrIl 2,170.0 psi Eminbend - xx 787.82 ksi Wood Species Trus Joist Fc - Perp 900.0 psi Wood Grade TimberStrand LSL 1.55E Fv 310.0 psi Ft 1,070.0 psi Density 44.990 pcf Beam Bracing Beam is Fully Braced against lateral -torsional buckling D( V 2) Q(0.0 i S(O.1) 1.75xll.875 1.75A 1.875 Span = 5.50 ft Span = 3.250 ft Applied Loads Service loads entered. Load Factors will be applied for calculations. Load for Span Number 1 Uniform Load: D = 0.020 ksf, Tributary Width = 6.0 ft, (ROOF) Load for Span Number 2 Uniform Load : D = 0.020, S = 0.0250 ksf, Tributary Width = 4.0 ft, (ROOF) L)k�it(iN �iUMMAHY Maximum Bending Stress Ratio 0.1041 Maximum Shear Stress Ratio 0.118 : 1 Section used for this span 1.75xl 1.875 Section used for this span 1.75xl 1.875 flo : Actual 277.36 psi fv : Actual 42.23 psi FB: Allowable 2,673.75 psi Fv: Allowable 356.50 psi Load Combination +D+S Load Combination +D+S Location of maximum on span 5.500ft Location of maximum on span 5.500 ft Span # where maximum occurs Span # 1 Span # where maximum occurs Span # 1 Maximum Deflection Max Downward Transient Deflection 0.021 in Ratio = 3766 >=360 Max Upward Transient Deflection -0.005 in Ratio = 14005 >=360 Max Downward Total Deflection 0.025 in Ratio = 3128 >=240. Max Upward Total Deflection -0.003 in Ratio = 26028 >=240. Overall Maximum Deflections Load Combination Span Max . ..... Defl Location in Span Load Combination Max."+" Defl Location in Span 1 0.0000 0.000 S Only -0.0047 3.196 +D+S 2 0.0249 3.250 0.0000 3.196 Vertical Reactions Support notation : Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Support 3 Overall MAXimum 0.253 1.088 Overall MINjmum -0.096 0.400 D Only 0.253 0.667 +D+S 0.157 1.088 +D+0.750S 0.181 0.983 P" b"M Wood Beam File= S1IobsXs181s1181%1811020 - 917 Pine Streeftwo 1181201811203 IF — enercalc trib 0811020.ed ENERCALC, INC. 1983-2017, Build:6.17.2.28, VT:6.17.2.2f Description: (1-13) C Vertical Reactions Support notation : Far left is #1 Values in KIPS bw Load Combination Support 1 Support 2 Support 3 +0.60D 0.152 0.400 S Only -0.096 0.421 —7 60 JIM t.. 6w File= SMobs\s18\s1811\s1811020 -917 Pine Streetwo 181203\181203 1F enerealctdb — s1811020.ed Im ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.17.2.2E _'Lic. #: KW-06006655 Licensee: SOUND STRUCTURAL SOLUTIONS Description : (1-13) B CODE REFERENCES Calculations per NDS 2015, 1 BC 2015, CBC 2016, ASCE 7-10 Load Combination Set: IBC 2015 Material Properties Analysis Method: Allowable Stress Design Fb - Tension 2,325.0 psi Load Combination IBC 2015 Fb - Compr 2,325.0 psi Fc - Prll 2,170.0 psi Wood Species Trus Joist Fc - Perp 900.0 psi Wood Grade TimberStrand LSL 1.55E Fv 310. 0 psi Ft 1,070.0 psi Beam Bracing Beam is Fully Braced against lateral -torsional buckling E: Modulus of Elasticity Ebend-xx 1,550.0 ksi Eminbend - xx 787.82 ksi Density 44.990 pcf 4 + D(O.12V(0.15) + + + Q( V 8) + + 31 1.75xil.875 1.75xil.875 Spa� = 5.50 ft Spw = 3.250 ft Applied Loads Service loads entered. Load Factors will be applied for calculations. Load for Span Number 1 Uniform Load : D = 0.020, S = 0.0250 ksf, Tributary Width = 6.0 ft, (ROOF) Load for Span Number 2 Uniform Load : D = 0.020 ksf, Tributary Width = 4.0 ft, (ROOF) DESIGN SUMMARY WON= 'Maximum Bending Stress Ratio 0.090.1 Maximum Shear Stress Ratio Section used for this span 1.75xl 1.875 Section used for this span fb : Actual 239.42 psi fv : Actual FB: Allowable 2,673.75 psi Fv: Allowable Load Combination +D+S Load Combination Location of maximum on span 2.458ft Location of maximum on span Span # where maximum occurs Span # 1 Span # where maximum occurs Maximum Deflection Max Downward Transient Deflection 0.008 in Ratio= 8017 ­360 Max Upward Transient Deflection -0.015 in Ratio= 5054 >=360 Max Downward Total Deflection 0.011 in Ratio = 5908 >=240. Max Upward Total Deflection -0.011 in Ratio = 6962 >=240. 0.166 : 1 1.75xl 1.875 59.14 psi 356.50 psi +D+S 5.500ft Span # 1 Overall Maximum Deflections Load Combination Span Max. "2' Defl Location in Span Load Combination Max. 'Y' Defl Location in Span +D+S 1 0.0112 2.642 0.0000 0.000 2 0.0000 2.642 S Only -0.0154 3.250 Vertical Reactions Support notation : Far left is #1 Values in KIPS Load Combination Suppoql Support 2 Support 3 Overall MAXimum 0.666 1.079 Overall MINimum 0.152 0.400 D Only 0.253 0.667 +D+S 0,666 1.079 +D+0.750S 0.563 0.976 Wood Beam IM AN "ATE I I 71TI MiTw Description : (1-13) B Vertical Reactions Load Combination +0.60D S Only low low SAJobs\s18ts181%1811020 - 917 Pine StreeAwo 1812031181203 1F-enerealc trib_s1811020,ec( ENERCALC. INC. 1983-2017. Build:6.17.2.28. Ver:6.1722E Support notation : Far left is #1 Values in KIPS Support 1 Support 2 Support 3 0.152 0.400 0.413 0.413 File= SAJobs\s18\s1811\s1811020- 917 Pine Street\wo 181203\181203 1F__pnercalc trib s1811020.ed Wood Beam ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.17.2.2E Lk. # : KW-06006655 Licensee: SOUND STRUCTURAL SOLUTION" Description : (1-13) C CODE REFERENCES Calculations per NDS 2015, 1 BC 2015, CBC 2016, ASCE 7-10 Load Combination Set: IBC 2015 Material Properties Analysis Method: Allowable Stress Design Fb - Tension 2,325.0 psi E: Modulus of Elasticity Load Combination JBC 2015 Fb - Compr 2,325.0 psi Ebend-xx 1,550.0 ksi Fc - PHI 2,170. 0 psi Eminbend - xx 787.82 ksi Wood Species Trus Joist Fc - Perp 900.0 psi Wood Grade TimberStrand LSL 1.55E Fv 310. 0 psi Ft 1,070.0 psi Density 44.990 pcf Beam Bracing Beam is Fully Braced against lateral -torsional buckling D(O.0 4 S(O.1) 1.75xll.875 Span = 3.250 ft Applied Loads Service loads entered. Load Factors will be applied for calculations. Uniform Load : D = 0.020, S = 0.0250 ksf, Tributary Width = 4.0 ft, (ROOF) Maximum Bending Stress Ratio 0.104.1 Maximum Shear Stress Ratio 0.118 : 1 Section used for this span 1.75xl 1.875 Section used for this span 1.75xl 1.875 fb: Actual 277.36 psi fv : Actual 42.23 psi FB: Allowable 2 673.75 psi Fv: Allowable 356.50 psi Load Combination +D+S Load Combination +D+S Location of maximum on span 0.000ft Location of maximum on span 0.000 ft Span # where maximum occurs Span # 1 Span # where maximum occurs Span # 1 Maximum Deflection Max Downward Transient Deflection 0.006 in Ratio= 12280 >=360 Max Upward Transient Deflection 0.000 in Ratio= 0 <360 Max Downward Total Deflection 0.011 in Ratio= 6822 ­240. Max Upward Total Deflection 0.000 in Ratio = 0 <240.0 Overall Maximum Deflectiors Load Combination Span Max. %" Defi Loration in Span Load Combination Max. 'Y' Defl Location in Span +D+S 1 0.0114 3.250 0.0000 0.000 Vertical Reactions Support notation Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Overall MAXimum 0.585 Overall MINimum 0.156 D Only 0.260 +D+S 0.585 +D+0.750S 0.504 +0.60D 0.156 S Only 0.325 Wood Beam File S:\Jobs\s18\s181 1\0811020 - 917 Pine StreOwo 181203\181203 11F_enercalc tril� s1811020.et.,( ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver6.1172;1 Lic. # : KW-06006655 Licensee., SOUND STRUCTURAL SOi—ILIT1,14 Description (1-14) CODE REFERENCES Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10 Load Combination Set: IBC 2015 Material Properties Analysis Method: Allowable Stress Design Fb - Tension 2,325.0 psi E Modulus of Elasticity Load Combination IBC 2015 Fb - Compr 2,325.0 psi Ebend-xx 1,550.Qksi Fc - Prll 2,170.0 psi Eminbend - xx 787.82 ksi Wood Species Trus Joist Fc - Perp 900.0 psi Wood Grade TimberStrand LSL 1.55E Fv 310.0 psi Ft 1,070.0 psi Density 44.990pcf Beam Bracing Beam is Fully Braced against lateral -torsional buckling too Q(0,03�(0.08) ----------------- - D(0,0 i S(01) U A 1.75�14 Span = 5.50 ft Applied Loads Service loads entered. Load Factors will be applied for calculations. Uniform Load D = 0.020, S = 0.0250 ksf, Tributary Width = 4.0 ft, (ROOF) Uniform Load D = 0.010 ksf, Tributary Width = 3.0 ft, (WALL) Uniform Load D = 0.0150, L = 0.040 ksf, Tributary Width = 2.0 ft, (FLOOR) Maximum Bending Stress Ratio Section used for this span fb : Actual FB: Allowable Load Combination Location of maximum on span Span # where maximum occurs Maximum Deflection Max Downward Transient Deflection Max Upward Transient Deflection Max Downward Total Deflection Max Upward Total Deflection Overall Maximum Deflections 0.083: 1 Maximum Shear Stress Ratio 1.75x14 Section used for this span 218.28psi fv : Actual 2,636.10psi Fv: Allowable +D+0.750L+0.750S Load Combination 2.750ft Location of maximum on span Span # 1 Span # where maximum occurs 0.003 in Ratio = 19767 >=360 0.000 in Ratio = 0 <360 0.009 in Ratio = 7188 >=240. 0.000 in Ratio = 0 <240.0 Load Combination Span Max . ..... Defl Location in Span Load Combination 0.130 : 1 1.75x14 46.30 psi 356.50 psi +D+0.750L+0.750S 0.000ft Span # 1 Max. "+" Defl Location h Span +D+0.150L+0.750S 1 0.0092 2.770 0.0000 01,000 Vertical Reactions Support notation : Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Overall MAXimum 0.756 0,756 Overall MINimum 0.220 0.220 D Only 0.385 0.385 +D+L 0.605 0.605 +D+S 0.660 0.660 +D+0.750L+0.750S 0.756 0.756 +0.60D 0.231 0.231 6w File= S.,XJobsksl8\sl8l%1811020-917P'ineStreet\wo 181203\181203 IF — enercalc trib—s'1811020.ed Im ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.17-2.2E Lic. # : KW-06006655 Licensee: SOUND STRUCTURAL SOLUTIONS Description : (1-14) Vertical Reactions Load Combination L Only S Only Support notation : Far left is #11 Values in KIPS Support 1 Support 2 0.220 0.220 0.275 0.275 Wood Beam File= S:\Jobs\s18ks1811\s1811020 - 917 Pine Street%wo 181203\181203 1F enercalctrib-0811020.e(j, ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.17.2.21 Lic. #: KW-06006655 Licensee I SOUND STRUCTURAL SOLUMt Description (1-15) CODE REFERENCES Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10 Load Combination Set: IBC 2015 Material Properties Analysis Method: Allowable Stress Design Fb - Tension 2,325.0 psi E: Modulus ofElasticity Load Combination IBC 2015 Fb - Compr 2,325.0 psi Ebend-xx 1,550.Oksi Fc - Prll 2,170.0 psi Eminbend - xx 787.82 ksi Wood Species Trus Joist Fc - Perp 900.0 psi Wood Grade TimberStrand LSL 1.55E Fv 310. 0 psi Ft 1,070.0 psi Density 44.990 pcf Beam Bracing Beam is Fully Braced against lateral -torsional buckling 1.7504 Span = 6.50 ft Applied Loads Service loads entered. Load Factors will be applied for calculations. Uniform Load : D = 0.0150, L = 0.040 ksf, Tributary Width = 5.0 ft, (FLOOR) Point Load D = 0.3850, L = 0.220, S = 0.2750 k 2.750 ft, ((1-14)) Point Load D = 0.3850, L = 0.220, S = 0.2750 k 3.50 ft, ((1-14)) DESIGN SUMMARY laximum Bending Stress Ratio 0.2921 Maximum Shear Stress Ratio 0.301 : 1 Section used for this span 1.75x14 Section used for this span 1.75x14 fib : Actual 670.19 psi fv : Actual 93.18 psi F`13: Allowable 2,292.26 psi Fv: Allowable 310.00 psi Load Combination +D+L Load Combination +D+L Location of maximum on span 3.345ft Location of maximum on span 0.000 ft Span # where maximum occurs Span # 1 Span # where maximum occurs Span # 1 Maximum Deflection Max Downward Transient Deflection 0.020 in Ratio= 3913 ­360 Max Upward Transient Deflection 0.000 in Ratio= 0 <360 Max Downward Total Deflection 0.038 in Ratio= 2031 ­240. Max Upward Total Deflection 0.000 in Ratio= 0 <240.0 Overall Maximum Deflections Load Combination Span Max. "-" Defl Location in Span Load Combination Max."+" Defl Location in Span +D+0.750L+0.750S 1 0.0384 3.250 0.0000 O.ODO Vertical Reactions Support notation Far left is #1 Values in KIPS Load Combination Support I Support 2 Overall MAXimum 1.522 1.475 Overall MINimum 0.286 0.264 D Only 0.644 0.614 4-D+L 1.522 1.475 4-D+S 0.929 0.878 +D+0.750L+0.750S 1.517 1.458 *0.60D 0.386 0.368 File= S:Uobs1s18Xs18Ms1811020-917 Pine Streellwo 1181201181203 1F_enercalctrib_s1811020.ed Wood Beam ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.17.2.2E Lic. #. KW-06006655 Licensee: SOUND STRUCTURAL SOLUTIONS Description : (1-15) Vertical Reactions Support notation: Far left is #1 Values in KIPS Load Combination Support 1 Support 2 L Only 0.878 0.862 S Only 0.286 0,264 6W r 6W lifflood Beam File= S:1Jobs%s18Xs1 1'�Ic. # - KW-06006655 Description CODE REFERENCES Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10 Load Combination Set: I BC 2015 Material Properties Analysis Method: Allowable Stress Design Fb - Tension Load Combination JBC 2015 Fb - Compr Fe - PrlI Wood Species Trus Joist Fc - Perp Wood Grade Parallam PSL 2.2E Fv Ft Beam Bracing Beam is Fully Braced against lateral -torsional buckling D(O.1 (0.48) 5.25xl4.0 Span = 18.0 ft 1020 - 917 Pine Streeftwo 1812031181203 1F_enerealc ENERCALC, INC. 1983-2017, Build:6.17. 2,900.0 psi E: Modulus of Elasticity 2,900.0 psi Ebend-xx 2,200.Oksi 2,900.0 psi Eminbend - xx 1, 118.19 ksi 625.0 psi 290.0 psi 2,025.0 psi Density 45.050 pef Applied Loads Service loads entered. Load Factors will be applied for calculations. Uniform Load: D = 0.0150, L = 0.040 ksf, Tributary Width = 12.0 ft, (FLOOR) ULWUN ZiUMMANY iff'.4111111111 Maximum Bending Stress Ratio 0.65e 1 Maximum Shear Stress Ratio 0.418 : 1 Section used for this span 5.25x14.0 Section used for this span 5.25x14.0 fb : Actual 1,870.32 psi fv : Actual 121.22 psi FI3 : AJIowable 2,850.80 psi Fv: Allowable 290.00 psi Load Combination +D+L Load Combination +D+L Location of maximum on span 9.000ft Location of maximum on span 0.000 ft Span # where maximum occurs Span # 1 Span # where maximum occurs Span # 1 Maximum Deflection Max Downward Transient Deflection 0.432 in Ratio= 500 >=360 Max Upward Transient Deflection 0.000 in Ratio= 0 <360 Max Downward Total Deflection 0.594 in Ratio= 363 >=240. Max Upward Total Deflection 0.000 in Ratio = 0 <240,0 Overall Maximum Deflections Load Combination Span Max. "-' Def! Location in Span Load Combination Max. 'Y' Defi Location in Span +D+L 1 0.5937 9.066 0.0000 0.000 Vertical Reactions Support notation Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Overall MAXimum 5.940 5.940 Overall MINimum 0.972 0.972 D Only 1.620 1.620 +D+L 5.940 5.940 +D+0.750L 4.860 4.860 +0.60D 0.972 0.972 L Only 4.320 4.320 on No Wood Beam File = S:\Jobs\s1ft181 Lic. #: KW-06006655 - Description : (1-17) CODE REFERENCES Calculations per NDS 2015, IBIC 2015, CBC 2016, ASCE 7-10 Load Combination Set: IBC 2015 Material Properties Analysis Method: Allowable Stress Design Fb - Tension Load Combination IBC 2015 Fb - Compr Fc - PrIl Wood Species Trus Joist Fc - Perp Wood Grade TimberStrand LSL 1.55E Fv Ft Beam Bracing Beam is Fully Braced against lateral -torsional buckling OR bw - 917 Pine Street\wo 111201181203 11F_enercalc 1rib_s1811020.ec' ENERCALC, INC. 1983-2017, Build:6.17.2.28 Ver:6.117,2Z Pill 00 Pq 2325 psi E: Modulus of Elasticity 2325 psi Ebend-xx 1550ksi two 2170 psi Eminbend - xx 787.815 ksi 900 psi IN 310 psi 1070 psi Density 44.99 pcf No D(O.12�(0.48) + 3.5x14 Span = 10.50 ft Applied Loads Service loads entered. Load Factors will be applied for calculations. Uniform Load: D = 0.0150, L = 0.040 ksf, Tributary Width = 12.0 ft, (FLOOR) DESIGN SUMMARY Maximum Bending Stress Ratio 0.4% 1 Maximum Shear Stress Ratio O�342 : 1 Section used for this span 3.5x14 Section used for this span 3.5x14 fib : Actual 954.64 psi fv : Actual 106.07 psi FB: Allowable 2,292.26 psi Fv: Allowable 310.00 psi Load Combination +D+L Load Combination +D+L Location of maximum on span 5.250ft Location of maximum on span 0.000ft Span # where maximum occurs Span # 1 Span # where maximum occurs Span # 1 Maximum Deflection Max Downward Transient Deflection 0.106 in Ratio= 1183 >=360 Max Upward Transient Deflectior 0.000 in Ratio= 0 <360 Max Downward Total Deflection 0.146 in Ratio= 860 ­240. Max Upward Total Deflection 0.000 in Ratio= 0 <240.0 —.Overall Maximum Deflections Load Combination Span +D+L I Yertical - Reactions Load Combination Overall MAXimum Overall MINimurn D Only +D+L +D+0.750L +0.60D L Only Max. "-" Defl Location in Span Load Combination 01464 5.288 Support notation Far left is #1 Support 1 Support 2 3.465 3,465 0.567 0,567 0.945 0.945 3.465 3.465 2.835 2.835 0.567 0.567 2.520 2.520 Max. 'Y' Defl Location in Span 0.0000 0.000 Values in KIPS Pill so an ow faw Wood Beam File= S:NJobs\s18\sl811\s1811020 - 917 Pine Streefto 181203\181203 I F_enercalc trib—s1811020.w III ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver.6.17.2.,�_A Lic. #: KW-06006655 Licensee - SOUND STRUCTURAL SCILL111410 Description CODE REFERENCES Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10 Load Combination Set: IBC 2015 Material Properties Analysis Method: Allowable Stress Design Fb - Tension 2900 psi E: Modulus of Elasticity Load Combination IBC 2015 Fb - Compr 2900 psi Ebend-xx 2200 ksi Fc - PrIl 2900 psi Eminbend - xx 1118.19 ksi Wood Species Trus Joist Fc - Perp 625 psi Wood Grade Parallam PSL 2.21E Fv 290 psi Ft 2025 psi Density 45.05 pcf Beam Bracing Beam is Fully Braced against lateral -torsional buckling 5.25x14.0 Span = 23.0 ft Applied Loads Service loads entered. Load Factors will be applied for calculations. Uniform Load: D = 0.0150, L = 0.040 ksf, Tributary Width = 1.333 ft, (FLOOR) Point Load: D = 1.620, L = 4.320 k @_ 1.250 ft, ((1 -16)) Point Load : D = 0.9450, L = 2.520 k 1.250 ft, ((1 -17)) DESIGN SUMMARY Maximum Bending Stress Ratio 0.30T. 1 Maximum Shear Stress Ratio Section used for this span 5.25x14.0 Section used for this span 5.25x14.0 fb : Actual 875.19 psi fv : Actual 198.71 psi FIB: Allowable 2,850.80 psi Fv: Allowable 290.00 psi Load Combination +D+L Load Combination +D+L Location of maximum on span 4.533ft Location of maximum on span 0.000 ft Span # where maximum occurs Span # I Span # where maximum occurs Span # 1 I Maximum Deflection Max Downward Transient Deflection 0.316 in Ratio= 872 >=360 Max Upward Transient Deflection 0.000 in Ratio = 0 <360 Max Downward Total Deflection 0.435 in Ratio = 634 ­240. Max Upward Total Deflection L 0.000 in Ratio = 0 <240.0 Overall Maximum Deflections Load Combination Span Max. Defl Location in Span Load Combination Max."+" Defl Location in Span +U+L 1 0.4351 10.493 0.0000 0.000 Vertical Reactions Support notation : Far left is #1 Values in KIPS Load Combination Support I Support 2 Overall MAXimum 9.737 1.354 Overall MINimum 1.593 0.222 D Only 2.656 0.369 +D+L 9.737 1.354 +D+0.750L 7.967 1.108 +0.60D 1.593 0.222 L Only 7.081 O�985 File= S:\Jobs\sl8\s1811\s1811020 - 9117 Pine Streetkwo 181203\181203 IF,.PnerGalc tdb s1811020.eC1 Wood Beam ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.17.2.2E Lic. #: KW-06006655 Description : (1-19) CODE REFERENCES Calculations per NDS 2015, 1 BC 2015, CBC 2016, ASCE 7-10 Load Combination Set: IBC 2015 Material Properties Analysis Method: Allowable Stress Design Fb - Tension Load Combination JBC 2015 Fb - Compr Fc - Prll Wood Species Trus Joist Fc - Perp Wood Grade MicroLam LVL 2.0 E Fv Ft Beam Bracing Beam is Fully Braced against lateral -torsional buckling *D(O.28 (0.35) V 3.500A4.000 Span = 16.0 ft OR bw 11" aw 2,600.0 psi E: Modulus of Elasticity 2,600.0 psi Ebend-xx 2,000.0 ksi 2,510.0 psi Eminbend - xx 1,016.54 ksi 750.0 psi 285.0 psi 1,555.0 psi Density 42.0 pef D(U8V(U5) Analied Loads Service loads entered. Load Factors will be applied for calculations. Uniform Load : D 0.0150, L = 0.040 , Tributary Width = 1.0 ft, (FLOOR) Point Load : D = 0.6830, S = 1.138 k @ 3.750 ft, (FRH) Uniform Load D = 0.010 ksf, Tributary Width = 9.0 ft, (WALL) Uniform Load D = 0.020, S = 0.0250 ksf, Extent = 10.125 ­> 16.0 ft, Tributary Width = 14.0 ft, (ROOF) Point Load : D = 0.6830, S = 1. 138 k @ 10. 125 ft, (FRH) Uniform Load: D = 0.020, S = 0.0250 ksf, Extent = 0.0 ­> 3.750 ft, Tributary Width = 14.0 ft, (ROOF) DESIGN SUMMARY 'Maximum Bending Stress Ratio 0.759.1 Maximum Shear Stress Ratio Section used for this span 3.500x14.000 Section used for this span fb : Actual 2,193.33 psi fv : Actual FB: Allowable 2,924.88 psi Fv: Allowable Load Combination +D+S Load Combination Location of maximum on span 10.102ft Location of maximum on span Span # where maximum occurs Span # I Span # where maximum occurs Maximum Deflection Max Downward Transient Deflection 0.301 in Ratio= 638 ­360 Max Upward Transient Deflection 0.000 in Ratio= 0 <360 Max Downward Total Deflection 0.606 in Ratio 316 >=240. Max Upward Total Deflection 0.000 in Ratio= 0 <240.0 0.534 :1 3.500x14.000 175.03 psi 327.75 psi +D+S 16.000ft Span # 1 Overall Maximum Deflections Load Combination Span Max. %" Defi Location in Span Load Combination Max. 'Y' Defi Location in Span +D+S 1 0.6060 8.175 0.0000 0.000 Vertical Reactions Support notation : Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Overall MAXimum 5.668 5.718 Overall MINimum 0.320 0.320 D Only 2.843 2.898 +D+L 3.163 3.218 00 No PM No PM 010 no 10 Pq ww am ow PW W No Wood Beam PIMEE�� Description : (1-19) Vertical Reactions Load Combination +D+S +D+0.750L+0.750S +0.60D L Only S Only = S:\Jobs\s1Ms181 11s1811020 - 917 Pine Support notation : Far left is #1 Support 1 Support 2 5.668 5.718 5.202 5.253 1.706 1.739 0.320 0.320 2.825 2.819 1812031181203 1F_enercalc trl�_sI811020.eci INC. 1983-2017, Build:6.17.2.28, Ver:6,17,2.21 Values in KIPS File= S.-Uobs\s18Xs1811\s1811020-917 Pine Streeftwo 1812D181203 'IF-enercalc trib-s1811020.ed Wood Beam ENERCALC, INC. 1983-2017, Build:6.17.228, Ver:6.17.2.2E 'Lic. #: KW-06006655 Licensee: SOUND STRUCTURAL SOLUTIONS Description : (1-20) CODE REFERENCES Calculations per NDS 2015, IBC 2015, CEIC 2016, ASCE 7-10 Load Combination Set: IBC 2015 Material Properties Analysis Method: Allowable Stress Design Fb - Tension 2,325.0 psi E: Modulus of Elasticity Load Combination IBC 2015 Fb - Compr 2,325.0 psi Ebend-xx 1,550.0 ksi Fc - Pill 2,170.0 psi Eminbend - xx 787.82 ksi Wood Species Trus Joist Fc - Perp 900.0 psi Wood Grade TimberStrand LSL 1.55E Fv 310. 0 psi Ft 1,070.0 psi Density 44.990 pcf Beam Bracing Beam is Fully Braced against lateral -torsional buckling D(O.U.35) 1.75x14 spa� = 8.0 ft Applied Loads Service loads entered. Load Factors will be applied for calculations. Uniform Load : D = 0.0150, L = 0.040 , Tributary Width = 1.0 ft, (FLOOR) Point Load : D = 0.6830, S = 1. 138 k @ 0.50 ft, (FRH) Uniform Load D = 0.010 ksf, Tributary Width = 9.0 ft, (WALL) Uniform Load D = 0.020, S = 0.0250 ksf, Extent = 6.875 ­> 8.0 ft, Tributary Width = 14.0 ft, (ROOF) Point Load : D = 0.6830, S = 1. 138 k Ca_) 6.875 ft, (FRH) Uniform Load: D = 0.020, S = 0.0250 ksf, Extent 0.0 ­> 0.50 ft, Tributary Width = 14.0 ft, (ROOF) DESIGN SUMMARY IMaximum Bending Stress Ratio 0.21e 1 Maximum Shear Stress Ratio 0.475 : 1 Section used for this span 1.75x14 Section used for this span 1.75x14 fb : Actual 570.22 psi fv : Actual 169.44 psi FB: Allowable 2,636.10 psi Fv: Allowable 356.50 psi Load Combination +D+S Load Combination +D+S Location of maximum on span 5.723ft Location of maximum on span 8.000ft Span # where maximum occurs Span # 1 Span # where maximum occurs Span # 1 Maximum Deflection Max Downward Transient Deflection 0.023 in Ratio 4111 >=360 Max Upward Transient Deflection 0.000 in Ratio= 0 <360 Max Downward Total Deflection 0.054 in Ratio = 1790 >=240. 1 Max Upward Total Deflection 0.000 in Ratio = 0 <240.0 Overall Maximum Deflections Load Combination Span Max. "-" Defl Location in Span Load Combination Max. 'Y' Defl Location in Span +D+S 1 0.0536 4.175 0.0000 0.000 Vertical Reactions Support notation : Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Overall MAXimum 2.738 2.767 Overall MINimum 0.160 0.160 D Only 1.314 1.347 +D+L 1.474 1.507 how Wood Beam SAJobsW81s1811W811020 - 917 Pine Streefiwo 181201181203 1 F_enercalc trib_s1811020.ecf ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.17.22E Description : (1-20) Vertical Reactions Support notation: Far left is #1 Values in KIPS Load Combination Support I Support 2 +D+S 2.738 2.767 +D+0.750L+0.750S 2.502 2.532 +0.60D 0.788 0.808 L Only 0.160 0.160 S Only 1.424 1.421 pq �i r PM bmw i IN 6wA He= SAJobs\s181s1811\s181l020 - 917 Pine Streefto 181203\181203 1F — enercalc tdbL_sl 811020.ed Wood Beam ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.1722E Description : (1-21) CODE REFERENCES Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10 Load Combination Set: IBC 2015 Material Properties Analysis Method: Allowable Stress Design Fb - Tension 2,325.0 psi E: Modulus of Elasticity Load Combination JBC 2015 Fb - Compr 2,325.0 psi Ebend-xx 1,550.0 ksi Fc - Prll 2,170.0 psi Eminbend - xx 787.82 ksi Wood Species Trus Joist Fc - Perp 900.0 psi Wood Grade TimberStrand LSL 1.55E Fv 310.0 psi R 1,070.0 psi Density 44.990 pef Beam Bracing Beam is Fully Braced against lateral -torsional buckling QMMIL1241S(0.11 DLCj�09) IF D(O.04IL(O.121 1.75M Sp-- 650 ft Applied Loads Service loads entered. Load Factors will be applied for calculations. Uniform Load : D = 0.0150, L = 0.040 ksf, Tributary Width = 3.0 ft, (FLOOR) Uniform Load: D = 0.010 ksf, Tributary Width = 9.0 ft, (WALL) Uniform Load: D = 0.020, L = 0.060, S 0.0250 ksf, Tributary Width 4.0 ft, (ROOF DECK) DESIGN SUMMARY '[Maximum Bending Stress Ratio 0.27a 1 Maximum Shear Stress Ratio 0.369 :1 Section used for this span 1.75x14 Section used for this span 1.75x14 fb : Actual 637.45 psi fv : Actual 114.41 psi FB: Allowable 2,292.26 psi Fv: Allowable 310.00 psi Load Combination +D+L Load Combination +D+L Location of maximum on span 3.250ft Location of maximum on span 0.000 ft I Span # where maximum occurs Span # 1 Span # where maximum occurs Span # 1 Maximum Deflection Max Downward Transient Deflection 0.023 in Ratio= 3326 >=360 Max Upward Transient Deflection 0.000 in Ratio = 0 <360 Max Downward Total Deflection 0.037 in Ratio = 2082 >=240. Max Upward Total Deflection 0.000 in Ratio= 0 <240.0 Overall Maximum Deflections Load Combination Span Max. Defi Location in Span Load Combination Max. 'Y' Defi Location in Span +D+L 1 0.0375 3.274 0.0000 0.000 Vertical Reactions Support notation : Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Overall MAXinnum 1.869 1.869 Overall MINimum 0.325 0.325 D Only 0.699 0.699 +D+L 1.869 1.869 +D+S 1.024 1.024 +D+0.750L+0,750S 1.820 1.820 +0.60D 0.419 0.419 on k"i Wood Beam Description (1-21) Vertical Reactions Load Combination L Only S Only PR I Pq L 5:NJobsNs18\s181 %1811020 - 917 Pine Streefto 181203\181203 IF_enercalc tr1b_s18l1020.ec1 ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.17.22f Support notation: Farleftis#1 Values in KIPS Support 1 Support 2 1.170 1.170 0.325 0.325 File= SAJobs\sWs1811\s1811G20 - 917 Pine Street\wo 181203k181203 1F—enercalc trib_s1811020.ed Wood Beam ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.1722E Lic. # : KW-06006655 Description : (1-22) CODE REFERENCES Calculations per NDS 2015, 1 BC 2015, CBC 2016, ASCE 7-10 Load Combination Set: IBC 2015 Material Properties Analysis Method: Allowable Stress Design Fb - Tension Load Combination IBC 2015 Fb - Compr Fc - Prll Wood Species Trus Joist Fc - Perp Wood Grade TimberStrand LSL 1.55E Fv Ft Beam Bracing Beam is Fully Braced against lateral -torsional buckling 3.5x14 Span = 14.50 ft I -at kaw w_ No IN!" No 54 2325 psi E: Modulus of Elasticity 2325 psi Ebend-xx 1550ksi 680 2170 psi Eminbend - xx 787.815ksi 900 psi ON 310 psi 1070 psi Density 44.99 pcf MW Applied Loads Service loads entered. Load Factors will be applied for calculations. Load for Span Number I Varying Uniform Load: D(S,E) = 0.06396-0.1650, L(S,E) = 0.1980->0.440 k/ft, Extent = 0.0 ­> 14.50 ft, Trib Width = 1.0 ft, (FLOOR) Uniform Load: D = 0.010 ksf, Tributary Width = 9.0 ft, (WALL) Varying Uniform Load : D(S,E) = 0.05303-4.0, L(S,E) = 0.1591-4.0, S(S,E) = 0.08839-4.0 k/ft, Extent = 0.0 ­> 14.50 ft, Trib Width = 1.0 ft, (ROOF DEC� Point Load : D = 1.307, S = 1.633 k 4.50 ft, ((2-17)) DESIGN. SUMMARY — ------- Maximum Bending Stress Ratio 0�89R 1 Maximum Shear Stress Ratio 0.524 : 1 Section used for this span 3.5x14 Section used for this span 3.5x14 flo : Actual 2,054.08 psi fv : Actual 162.47 psi FB: Allowable 2,292.26 psi Fv: Allowable 310.00 psi Load Combination +D+L Load Combination +D+L Location of maximum on span 6.721 ft Location of maximum on span 0.000ft Span # where maximum occurs Span # 1 Span # where maximurn occurs Span # 1 Maximum Deflection Max Downward Transient Deflection 0.321 in Ratio= 541 >=360 Max Upward Transient Deflection 0.000 in Ratio = 0 <360 Max Downward Total Deflection 0.638 in Ratio = 272 >=240, Max Upward Total Deflection 0.000 in Ratio= 0 <240.0 Overall M ax innum Deflections - - Load Combination Span Max."-" Defl Location in Span Load Combination +D+0.750L+0.750S 1 0.6376 7.091 Vertical Reactions Support notation : Far left is #1 Load Combination Support I Support 2 Overall MAXimum 5.775 5.128 Overall MINimum 1,511 0.720 D Only 2.518 2.138 +D+L 5.307 5.128 +D+S 4.072 2.859 Max. 'Y' Defl Location in Span 0.0000 0.000 Values in KIPS Wood Beam File= SAJobs\s18\s18Ms1811020 - 917 Pine Streetwo 118112011811203 1F_enercalc trl�_s1811020.e.( ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.17.22E Description : (1-22) Vertical Reactions Support notaltion : Far left is #1 Values in KIPS Load Combination Support I Support 2 +D+0.750L+0.750S 5.775 4.921 +0.60D 1.511 1.283 L Only 2.789 2.990 S Only 1.553 0.720 mid Wood Beam File = &UoWsiffisl Lic. #: KW.06006655 Description : (1-23) CODE REFERENCES Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10 Load Combination Set: IBC 2015 Material Properties Analysis Method: Allowable Stress Design Fb - Tension Load Combination IBC 2015 Fb - Compr Fc - Prll Wood Species Trus Joist Fc - Perp Wood Grade MicroLam LVL 2.0 E Fv Ft Beam Bracing Beam is Fully Braced against lateral -torsional buckling 81 %1811020 - 917 Pine Streefto 181203\181203 1F-Onercalc trib_s1811020.eo ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.17.2,2I 2600 psi 2600 psi 2510 psi 750 psi 285 psi 1555 psi D( 9) D(0.ZR`ll)M@AJRdq0)349) V 1)(0.01) L(O.04) X 3.500x14.000 Span = 6.0 ft E: Modulus of Elasticity Ebend-xx 2000 ksi Eminbend - xx 1016.535ksi Density 42 pef Applied Loads Service loads entered. Load Factors will be applied for calculations. Uniform Load D = 0.010, L = 0,040 Tributary Width = 1.0 ft, (FLOOR) Uniform Load D = 0.010 ksf, Extent 0.0 ­> 5.0 ft, Tributary Width = 9,0 ft, (WALL) Point Load : D = 0.2610, L = 0.6170, S = 0.3490 k @ 5.0 ft, ((2-10)) Point Load: D = 1,594, L = 2.656 k @ 5.0 ft, ((2-14)) Maximum Bending Stress Ratio Section used for this span flo : Actual FB: Allowable Load Combination Location of maximum on span Span # where maximum occurs Maximum Deflection Max Downward Transient Deflection Max Upward Transient Deflection Max Downward Total Deflection Max Upward Total Deflection 0. 1 89r 1 Maximum Shear Stress Ratio 3.500x14.000 Section used for this span 480.88 psi fv : Actual 2,543.37 psi Fv: Allowable +D+L Load Combination 4.993 ft Location of maximum on span Span # 1 Span # where maximum occurs 0.009 in Ratio 8393 ­360 0.000 in Ratio= 0 <360 0.015 in Ratio= 4890 >=240.. 0.000 in Ratio= 0 <240.0 W, No Aq "d AV on AM pa 0.495 : 1 3.500x14.000 141.15 psi 285.00 psi +D+L 6.000ft Span # 1 00� Overall Maximum Deflections - Load Combination Span Max. "-" Defl Location in Span Load Combination Max. "+" Defi Location in Span +D+L Vertical Reactions 1 0.0147 3.350 Support notation Far left is #1 0.0000 0.000 Values in KIPS MW Load Combination Support 1 Support 2 Overall M"murn 1.267 4.611 PW Overall MINimurn 0.058 0.291 D Only 0.602 1.763 +D+L 1.267 4.611 +D+S 0.660 2.054 0M +D+0.750L+0.750S 1.144 4.117 tow w Flifflood Beam Description : (1-23) File= S:VMs1s181s181%1811020 -917 Pine StreeAwo 1812031181203 1 F—enercalc trib — S1 81 1020.e.i ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.1722E Vertical Reactions Support notabon : Far left is #1 Values in KIPS Load Combination Support I Support 2 +0.60D 0.361 1.058 L Only 0.666 2.848 S Only 0.058 0.291 ri Pq I PM I"I go - File= SAJobsW8\s181 1\s1811G20 - 917 Pine Streetkwo 181203\CRAWL_enercalc trib 180131_.ec( 1M ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.17.2.2f Lic. #: KW-06006655 Licensee: SOUND STRUCTURAL SOLUTIONS Description : (0-1) CODE REFERENCES Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10 Load Combination Set: IBC 2015 Material Properties Analysis Method: Allowable Stress Design Fb - Tension Load Combination IBC 2015 Fb - Compr Fc - Prll Wood Species Douglas Fir - Larch Fc - Perp Wood Grade No.2 Fv Ft Beam Bracing Beam is Fully Braced against lateral -torsional buckling Rm Sp.n = 6.0 ft 900.0 psi 900.0 psi 1,350.0 psi 625.0 psi 180.0 psi 575.0 psi E: Modulus of Elasticity Ebend-xx 1,600.0 ksi Eminbend - xx 580.0 ksi owl MW 00 %no I" Density 31.20pcf mm Applied Loads Service loads entered. Load Factors will be applied for calculations. Uniform Load: D = 0.0150, L = 0.040 ksf, Tributary Width = 18.0 ft, (FLOOR) Uniform Load : D = 0.010 ksf, Tributary Width 9.0 ft, (WALL) DESIGN SUMMARY Maximurn Bending Stress Ratio 0198: 1 Maximum Shear Stress Ratio Section used for this span 4x1 2 Section used for this span fb : Actual 789.94 psi fv : Actual FB: Allowable 990.00 psi Fv: Allowable Load Combination +D+L Load Combination I Location of maximum on span 3.000ft Location of maximum on span Span # where maximum occurs Span # 1 Span # where maximum occurs Maximum Deflection Max Downward Transient Deflection 0.032 in Ratio= 2265 >=360 Max Upward Transient Deflection 0.000 in Ratio = 0 <360 Max Downward Total Deflection 0.048 in Ratio = 1510 >=240. Max Upward Total Deflection 0.000 in Ratio= 0 <240.0 Maximum Deflections --Overall - - Load Combination Span Max . ..... Defl Location in Span Load Combination Vertical Reactions Load Combination Overall MAXimum Overall MINimum D Only +D+L +D+0.750L +0.60D L Only 1 0.0477 3.022 Support notation : Far left is #1 Support 1 Support 2 3.240 3,240 0.648 0.648 1.080 1.080 3.240 3.240 2.700 2.700 0.648 0.648 2.160 2.160 00 wa ION 0.686 : 1 fto 4x12 123.43 psi $01 180.00 psi +D+L we 0.000 ft Span # 1 Max. 'Y' Defi Location in Span Values in KIPS MR hm P0 wo low no M 4no so wo PIN boo Pill PIN VIA 6* Fill PIN Wood Column File= S:kJobs\s18\s1811\s1811020 - 917 Pine Streetwo 181203\181203 columns-enercalc trib_s1811020.eri ENERCALC, INC. 1983-2017, Build:6.17.2,28, Ver:6.172'2f Lic. # : KW-06006655 Licensee -. souNb STRUCTURAL SOI Description : (1-9) #2 + (1-6) #1 + FRH + (2-13) #2 + (2-5) #1 + (2-12) Code References Calculations per NIDS 2015, 1 BC 2015, CIBC 2016, ASCE 7-10 Load Combinations Used: I BC 2015 General Information Analysis Method Allowable Stress Design Wood Section Name 6x6 End Fixities Top & Boftom Pinned Wood Grading/Manuf. Graded Lumber Overall Column Height 10.250 ft Wood Member Type Sawn ( Used for non-s/ender calculations Exact Width 5.50 in Allow Stress Modification Factors Wood Species Douglas Fir - Larch Exact Depth 5.50 in Cf or Cv for Bending 1.0 Wood Grade No.1 Area 30.25 in12 Cf or Cv for Compression 1.0 Fb - Tension 1,200.0 psi Fv 170.0 psi Ix 76.255 in14 Cf or Cv for Tension 1.0 Flb - Compr 1,200.0 psi Ft 825.0 psi ly 76.255 in14 Cm: Wet Use Factor 1.0 Fc - PrIl 1,000.0 psi Density 31.20 pcf Ct : Temperature Factor 1.0 Fc - Perp 625�O psi E : Modulus of Elasticity ... x-x Bending y-y Bending Axial Cfu : Flat Use Factor Kf: Built-up columns 1.0 1 . 0 1410) 15. 3. 2 Basic 1,600.0 1,600.0 1,600.0 ksi Use Cr: Repetitive ? No Minimum 580.0 580.0 Brace condition for deflection (buckling) along columns : XA (width) axis : Unbraced Length for XA Axis buckling = 10.250 ft, K = 1.0 Y-Y (depth) axis: Unbraced Length for XA Axis buckling = 10.250 ft, K = 1.0 Applied Loads Service loads entered. Load Factors will be applied for calculations. Column self weiqht included : 67.180 lbs * Dead Load Factor AXIAL LOADS ... Axial Load at 10.250 ft, D = 5.118, L = 5.065, S = 4.605 k DESIGN SUMMARY Bending & Shear Check Results PASS Max. Axial+Bending Stress Ratio 0.5739 :1 Maximum SERVICE Lateral Load Reactions.. Load Combination +D+0.750L+0.750S Top along Y-Y 0.0 k Bottom along Y-Y 0.0 k Governing NDS Forumla Comp Only, fc/Fc' Top along XA 0.0 k Bottom along X-X 0.0 k Location of max.above base 0.0 ft Maximum SERVICE Load Lateral Deflections ... At maximum location values are ... Along Y-Y 0,0 in at 0.0 ft above base Applied Axial 12.438 k for load combination : n1a Applied Mx 0.0 k-ft Applied My 0.0 k-ft Along X-X 0.0 in at 0.0 ft above base Fc: Allowable 716.46 psi for load combination : n/a Other Factors used to calculate allowable stresses ... PASS Maximum Shear Stress Ratio 0.0 : 1 Bending Compression Tension Load Combination +0.460D Location of max.above base 10.250 ft Applied Design Shear 0.0 psi Allowable Shear 272.0 psi Load Combination Results Maximum Axial + Bending Stress Ratios Maximum Shear Ratios Load Combination C D C P Stress Ratio Status Location Stress Ratio Status Location D Only 0.900 0.710 0.2681 PASS 0.0 ft 0.0 PASS 10,250 ft +D+L 1.000 0.674 0.5026 PASS O.Oft 0.0 PASS 10.250 ft +D+S 1.150 0.623 0.4517 PASS 0.0 ft 0.0 PASS 10.250 ft +D+0.750L+0.750S 1.150 0.623 0.5739 PASS 0.0ft 0.0 PASS 10.250 ft +1.140D 1.600 0.497 0.2456 PASS 0.0ft 0.0 PASS 10.250 ft +1.105D+0.750L+0.750S 1.600 0.497 0.5393 PASS O.Oft 0.0 PASS 10.250 ft +0.60D 1.600 0.497 0.1292 PASS O.Oft 0.0 PASS 10.250 ft +0.460D 1,600 0.497 0.09908 PASS O.Oft 0.0 PASS 10.250 ft MR File= S:Uobs1s181s1811%s1811020 - 917 Pine Streetwo 181203\181203 columns-enercalc trib_s'18111020.ed Nood Column ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.17.2.2f -ic. #: KW-06006655 Licensee: SOUND STRUCTURAL SOLUTION" Description : (2-11)#3 + (1-7)#3 Code References Calculations per NDS 2015, 1 BC 2015, CBC 2016, ASCE 7-10 Load Combinations Used : IBC 2015 General Information Analysis Method Allowable Stress Design End Fixities Top & Bottom Pinned Overall Column Height 9.50 ft ( Used for non -slender calculaticns Wood Species Douglas Fir - Larch Wood Grade No.1 Flb - Tension 1,200.0 psi Fv 170.0 psi Fb - Compr 1,200.0 psi Ft 825.0 psi Fc - PHI 1,000.0 psi Density 31.20 pcf Fc - Perp 625.0 psi E : Modulus of Elasticity ... x-x Bending y-y Bending Basic 1,600.0 1,600.0 Minimum 580.0 580.0 Wood Section Name 6x6 Wood Grading/Manuf. Graded Lumber Wood Member Type Sawn Exact Width 5.50 in Allow Stress Modification Factors Exact Depth 5.50 in Cf or Cv for Bending 1.0 Area 30.25 in A 2 Cf or Cv for Compression 1.0 Ix 76.255 in A 4 Cf or Cv for Tension 1.0 ly 76.255 inA4 Cm :Wet Use Factor 1.0 Ct jemperature Factor 1.0 Cfu : Flat Use Factor 1.0 Axial Kf : Built-up columns 1.0 NDS 15.3.2 1,600.0 ksi Use Cr: Repetitive ? No : Now Brace condition for deflection (buckling) along columns: X-X (width) axis: Unbraced Length for X-X Axis buckling = 9.50 ft, K = 1.0 Y-Y (depth) axis: Unbraced Length for XA Axis buckling = 9.50 ft, K = 1.0 Aoolied Loads Service loads entered. Load Factors will be applied for calculations. Column self weiqht included : 62.265 lbs * Dead Load Factor AXIAL LOADS ... Axial Load at 9.50 ft, D = 8.995, L 7.921, S = 5.293 k DESIGN SUMMARY Bending & Shear Check Results PASS Max. Axial+Bending Stress Ratio 0.8036 :1 Maximum SERVICE Lateral Load Reactions.. Load Combination +D+0.750L+0.750S Top along Y-Y 0.0 k Bottom along Y-Y 0.0 k Governing NDS Forumla Comp Only, fc/Fc' Top along X-X 0.0 k Bottom along XA 0.0 k Location of max.above base 0.0 ft Maximum SERVICE Load Lateral Deflections ... At maximum location values are ... Along Y-Y 0.0 in at 0.0 ft above base Applied Axial 18.968 k for load combination : n/a Applied Mx 0,0 k-ft Applied My 0.0 k-ft Along X-X 0.0 in at 0.0 ft abovebase Fc: Allowable 780.31 psi for load combination: n/a Other Factors used to calculate allowable stresses ... PASS Maximum Shear Stress Ratio= 0.0 :1 Bending Compression, Tension Load Combination +0.460D Location of max.above base 9.50 ft Applied Design Shear 0.0 psi Allowable Shear 272.0 psi Load Combination Results Maximum Axial + Bending Stress Ratios Maximum Shear Ratios Load Combination C D C P Stress Ratio Status Location Stress Ratio Status Location D Only 0.900 0.758 0.4389 PASS 0.0ft 0.0 PASS 9.50 ft +D+L 1.000 0.726 0.7734 PASS 0.0 ft 0.0 PASS 9.50 ft +D+S 1.150 0.679 0.6079 PASS 0.0 ft 0.0 PASS 9.50 ft +D+0.750L+0.750S 1.150 0.679 0.8036 PASS 0.0 ft 0.0 PASS 9.50 ft +1.140D 1.600 0.555 0.3843 PASS 0.0 ft 0.0 PASS 9.50 ft +1.105D+0.750L+0.750S 1.600 0.555 0.7414 PASS 0.0 ft 0.0 PASS 9.50 ft +0.60D 1.600 0.555 0.2023 PASS O.Oft 0.0 PASS 9.50 ft +0.460D 1.600 0.555 0.1551 PASS 0.0ft 0.0 PASS 9.50 ft Wood Column Description : (1-6) #2 + (2-5) #2 Code References Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10 Load Combinations Used : IBC 2015 General Information I Wd Analysis Method Allowable Stress Design, End Fixities Top & Bottom Pinned Overall Column Height 10.250 ft ( U.sed for non -slender calculations Wood Species Douglas Fir - Larch Wood Grade No.1 Fb - Tension 1,200.0 psi Fv 170.0 psi J Fb - Compr 1,200.0 psi Ft 825.0 psi Fc - PrIl 1,000.0 psi Density 31.20 pcf Fc - Perp 625.0 psi E : Modulus of Elasticity ... x-x Bending y-y Bending Basic 1,600.0 1,600.0 Minimum 580.0 580.0 Applied Loads olumn self weiqht included : 67.180 lbs * Dead Load Factor AXIAL LOADS ... Axial Load at 10.250 ft, D = 4.478, L = 6.108, S = 6.343 k DESIGN SUMMARY S:Uobs\s1Msl8Msl8l1020-917 Pine Streefto T81203\181203 columns enercalc trib S1811020.ed ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.17.2.2f Wood Section Name 6x6 Wood Grading/Manuf. Graded Lumber Wood Member Type Sawn Exact Width 5.50 in Allow Stress Modification Factors Exact Depth 5.50 in Cf or Cv for Bending 1.0 Area 30.25 in A 2 Cf or Cv for Compression 1.0 Ix 76.255 in14 Cf or Cv for Tension 1.0 ly 76.255 in,14 Cm : Wet Use Factor 1�0 Ct : Temperature Factor 1.0 Cfu : Flat Use Factor 1.0 Axial Kf : Built-up columns 1.0 NDS 15.3.2 1,600.0 ksi Use Cr: Repetitive ? No Brace condition for deflection (buckling) along columns : X-X (width) axis: Unbraced Length for X-X Axis buckling = 10.250 ft, K = 1.0 Y-Y (depth) axis: Unbraced Length for XA Axis buckling = 10.250 ft, K = 1.0 Service loads entered. Load Factors will be anolied for calculations. Bending & Shear Check Results PASS Max. Axia]+Bending Stress Ratio 0.6406 :1 Maximum SERVICE Lateral Load Reactions.. Load Combination +D+0.750L+0.750S Top along Y-Y 0.0 k Bottom along Y-Y 0.0 k Governing NOS Forumla Location Comp Only, fc/Fc' Top along X-X 0.0 k Bottom along XA 0.0 k of max.above base 0.0 ft Maximum SERVICE Load Lateral Deflections ... At maximum location values are ... Along Y-Y 0.0 in at 0.0 ft abovebase Applied Axial 13.883 k for load combination: n/a Applied Mx 0.0 k-ft Applied My 0.0 k-ft Along X-X 0.0 in at 0.0 ft above base Fc: Allowable 716.46 psi for load combination : n/a Other Factors used to calculate allowable stresses ... PASS Maximum Shear Stress Ratio 0.0 : 1 Bendinq Compression Tension Load Combination +0.460D Location of max.above base 10.250 ft i6w Applied Design Shear 0.0 psi Allowable Shear 272.0 psi 0.0 Load Combination Results MW Maximum Axial + Bending Stress Ratios Maximum Shear Ratios Load Combination C D C P Stress Ratio Status Location Stress Ratio Status Location D Only 0.900 0.710 0.2350 PASS 0.0 It 0.0 PASS 10.250 fl +D+L 1.000 0.674 0.5223 PASS 0.0 ft 0.0 PASS 10.250 ft +D+S 1.150 0.623 0.5024 PASS 0�0 ft 0.0 PASS 10.250 ft +D+0.750L+0.750S 1.150 0.623 0.6406 PASS 0.0 ft 0.0 PASS 10.250 ft +1.140D 1.600 0.497 0.2152 PASS 0.0 ft 0.0 PASS 10.250 ft +1.105D+0.750L+0.750S 1.600 0.497 0.5966 PASS 0.0 ft 0.0 PASS 10.250 ft +0.60D 1.600 0.497 0.1133 PASS 0.0 ft 0.0 PASS 10.250 ft +0.460D 1.600 0.497 0.08685 PASS 0.0 ft 0.0 PASS 10.250 ft File= S:kJobs\s18\s1811\s1811020-917 Pine Street\wo 181203\181203 columns - enercalc tdb_s1811020.ec( Wood Column ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.1722E Lic. # : KW-06006655 Licensee - SOLIN Mok - Description : (2-11#2 + (1-7#2 Code References Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10 Load Combinations Used : IBC 2015 General Information Analysis Method Allowable Stress Design End Fixities Top & Bottom Pinned Overall Column Height 10.250 ft ( Used for non -slender calculatians Wood Species Douglas Fir - Larch Wood Grade No.1 Fb - Tension 1,200.0 psi Fv 170.0 psi Fb - Compr 1,200.0 psi Ft 825.0 psi Fc - PrIl 1,000.0 psi Density 31.20 pcf Fc - Perp 625.0 psi E : Modulus of Elasticity ... x-x Bending y-y Bending Basic 1,600.0 1,600.0 Minimum 580.0 580.0 Applied Loads Column self weiqht included : 67.180 lbs Dead Load Factor AXIAL LOADS. . . Axial Load at 10.250 It, D = 11.877, L 12,444, S = 8.230 k DESIGN SUMMARY Bending & Shear Check Results FAIL Max. Axial+Bending Stress Ratio Load Combination Governing NDS Forumla Location of max.above base At maximum location values are ... Applied Axial Applied Mx Applied My Fc: Allowable PASS Maximum Shear Stress Ratio= Load Combination Location of max.above base Applied Design Shear Allowable Shear Load Combination Results 1.267 :1 +D+0.750L+0.750S Comp Only, fc/Fc' 0.0 It 27.450 k 0.0 k-ft 0.0 k-ft 716.46 psi 0.0 :1 +0.460D 10.250 It 0.0 psi 272.0 psi Wood Section Name 6x6 Wood Grading/Manuf. Graded Lumber Wood Member Type Sawn Exact Width 5.50 in Allow Stress Modification Factors Exact D . epth 5.50 in Cf or Cv for Bending 1.0 Area 30.25 inA2 Cf or Cv for Compression 1.0 Ix 76.255 in'4 Cf or Cv for Tension 1.0 ly 76.255 in14 Cm: Wet Use Factor 1.0 Ct : Temperature Factor 1.0 Cfu : Flat Use Factor 1.0 Axial Kf : Built-up columns 1.0 NDS 15.3.2 1,600.0 ksi Use Cr: Repetitive ? No Brace condition for deflection (buckling) along columns : X-X (width) axis: Unbraced Length for X-X Axis buckling = 10.250 ft, K = 1.0 Y-Y (depth) axis: Unbraced Length for X-X Axis buckling = 10.250 ft, K = 1.0 Service loads entered. Load Factors will be applied for calculations. Maximum SERVICE Lateral Load Reactions.. Top along Y-Y 0.0 k Bottom along Y-Y 0.0 k Top along XA 0.0 k Bottom along X-X 0.0 k Maximum SERVICE Load Lateral Deflections ... Along Y-Y 0.0 in at 0.0 It abovebase for load combination: n/a Along XA 0.0 in at 0.0 ft above base for load combination : n/a Other Factors used to calculate allowable stresses ... Bending Compression Tension Maximum Axial + Bending Stress Ratios Maximum Shear Ratios Load Combination C D C P Stress Ratio Status Location Stress Ratio Status Location D Only 0.900 0.710 0.6175 PASS 0.0 ft 0.0 PASS 10.250 It +D+L 1.000 0.674 1.196 FAIL! 0.0ft 0.0 PASS 10.250 ft +D+S 1.150 0.623 0.9308 PASS 0.0 It 0.0 PASS 10.250 It +D+0.750L+0.750S 1.150 0.623 1.267 FAIL! 0.0 ft 0.0 PASS 10.250 ft +1.140D 1.600 0.497 0.5656 PASS 0.0 ft 0.0 PASS 10.250 ft +1.105D+0.750L+0.750S 1.600 0.497 1.192 FAIL! O.Oft 0.0 PASS 10.250 ft +0.60D 1.600 0.497 0.2977 PASS 0.0ft 0.0 PASS 10.250 ft +0.460D 1.600 0.497 0.2282 PASS 0.0 It 0.0 PASS 10.250 It Will wao 0111111� JIM Pill on up No Pill 'M Wood Column File= S:Uobs\s1ffis1811\s1811020 - 917 Pine Streefto T8120181203 columns enercalctrib-s1811020.0 ENERCALC, INC. 1983-2017, Build:6.17.2.28,Ver.6.17.22E Description : (1-2) + (1-8)#2 C + (2-19)#2 C Code References Calculations per INDS 2015, IBC 2015, CBC 2016, ASCE 7-10 Load Combinations Used: I BC 2015 -General Information Analysis Method Allowable Stress Design Wood Section Name 6x6 End Fixities Top & Bottom Pinned Wood Grading/Manuf. Graded Lumber Overall Column Height 10.250 ft Wood Member Type Sawn ( Used for non -slender calculations Wood Species Douglas Fir - Larch Exact Width 5.50 in Allow Stress Modification Factors Wood Grade No.1 Exact Depth 5.50 in Cf or Cv for Bending 1.0 Fb - Tension 1,200.0 psi Fv 170.0 psi Area 30.25 in A 2 Cf or Cv for Compression 1.0 Fb - Compr 1,200.0 psi Ft 825.0 psi Ix 76,255 inA4 Cf or Cv for Tension 1.0 Fc - PrIl 1,000.0 psi Density 31.20 pcf ly 76.255 inA4 Cm : Wet Use Factor 1.0 Fc - Perp 625.0 psi Ct : Temperature Factor 1.0 E : Modulus of Elasticity ... x-x Bending y-y Bending Axial Cfu : Flat Use Factor 1.0 Kf : Built-up columns 1.0 NOS 15.3.2 Basic 1,600.0 1,600.0 1,600.0 ksi Use Cr: Repetitive ? No Minimum 580.0 580.0 Brace condition for deflection (buckling) along columns : X-X (width) axis: Fully braced aqainst buckling along XA Axis Y-Y (depth) axis: Fully braced aqainst buckling along Y-Y Axis -Applied Loads Service loads entered. Load Factors will be applied for calculations. Column self weiqht included 67.180 lbs * Dead Load Factor AXIAL LOADS ... Axial Load at 10.250 ft, D = 6.362, L ='7.403, S = 3.773 k DESIGN SUMMARY Bending & Shear Check Results �iww rm,')a Max. Axial+Denchng CAress MdL]U 0.4573 : 11 Maximum SERVICE Lateral Load Reactions.. Load Combination +D+L Top along Y-Y 0.0 k Bottom along Y-Y 0.0 k Governing INDS Forumla Location of max.above base Comp Only, fc/Fc' 0.0 ft Top along X-X 0.0 k Bottom along XA 0.0 k At maximum location values are Maximum SERVICE Load Lateral Deflections ... ... Along Y-Y 0.0 in at 0.0 ft above base Applied Axial 13.832 k for load combination : n1a Applied Mx 0.0 k-ft Applied My 0.0 k-ft Along X-X 0.0 in at 0.0 ft abovebase Fc: Allowable 1,000.0 psi for load combination : n/a Other Factors used to calculate allowable stresses ... PASS Maximum Shear Stress Ratio= 0.0 :1 Bending Compression Tension Load Combination +0.460D Location of max.above base 10.250 ft Applied Design Shear 0.0 psi Allowable Shear 272.0 psi Load Combination Results Maximum Axial + Bending Stress Ratios Maximum Shear Ratios Load Combination C D C P Stress Ratio Status Location Stress Ratio Status Location D Only 0.900 1.000 0.2362 PASS 0.0 ft 0.0 PASS 10.250 ft +D+L 1.000 1.000 0.4573 PASS 0.0 ft 0.0 PASS 10.250 ft +D+S 1.150 1.000 0.2933 PASS 0.0 ft 0.0 PASS 10.250 ft +D+0.750L+0.750S 1.150 1.000 0.4258 PASS 0.0 ft 0.0 PASS 10.250 ft +1.140D 1.600 1.000 0.1514 PASS 0.0 ft 0.0 PASS 10.250 ft +1.105D+0.750L+0.750S 1.600 1.000 0.320 PASS 0.0 ft 0.0 PASS 10.250 ft +0.60D 1.600 1.000 0.07970 PASS O.Oft 0.0 PASS 10.250 ft +0.460D 1.600 1.000 0.06110 PASS O.Oft 0.0 PASS 10.250 ft File= S.\Jobs\s18ks18l1\s1811020 - 917 Pine Street\wo 181203\181203 columns_enercalc trib�_s1811020.ed Nood Column ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.17.2.2i Lic. #: KW-06006655 Licensee: SOUND STRUCTURAL SOLUTI= Description : (2-17) + (2-16)#2 Code References Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10 Load Combinations Used : IBC 2015 General Information Analysis Method: Allowable Stress Design Wood Section Name 6x6 I End Fixities Top & Bottom Pinned Wood Grading/Manuf. Graded Lumber %NE1 Overall Column Height 9.0 ft Wood Member Type Sawn ON ( Used for non -slender calculations Exact Width 5.50 in Allow Stress Modification Factors Wood Species Douglas Fir - Larch Exact Depth 5.50 in Cf or Cv for Bending 1.0 Wood Grade No.1 Area 30.25 in12 Cf or Cv for Compression 1.0 Fb - Tension 1,200.0 psi Fv 170.0 psi Ix 76.255 in'4 Cf or Cv for Tension 1.0 Fb - Compr 1,200.0 psi Ft 825.0 psi ly 76.255 in14 Cm : Wet Use Factor 1.0 Fc - Pill 1,000.0 psi Density 31.20 pcf Ct: Temperature Factor 1.0 Fc - Perp 625.0 psi Cfu : Flat Use Factor 1.0 E : Modulus of Elasticity ... x-x Bending y-y Bending Axial Kf: Built-up columns 1.0 NDS 1512 Basic 1,600.0 1,600.0 1,600.0 ksi Use Cr: Repetitive ? No Minimum 580.0 580.0 Brace condition for deflection (buckling) along columns : X-X (width) axis: Unbraced Length for XA Axis buckling = 9.0 ft, K = 1.0 Y-Y (depth) axis: Unbraced Length for XA Axis buckling = 9.0 ft, K = 1.0 Applied Loads Service loads entered. Load Factors will be applied for calculations. low Column self weiqht included : 58.988 lbs * Dead Load Factor 11", AXIAL LOADS. . . Axial Load at 9.0 ft, D = 4.073, S = 5.410 k 1%0 DESIGN SUMMARY Bending & Shear Check Results PASS Max, Axial+Bending Stress Ratio 0.3834:1 Load Combination +D+S Governing NDS Forumla Comp Only, fc/Fc' Location of max.above base 0.0 ft At maximum location values are. Applied Axial 9.542 k Applied Mx 0,0 k-ft Applied My 0.0 k-ft Fc: Allowable 822.75 psi PASS Maximum Shear Stress Ratio 0.0 :1 Load Combination +0.460D Location of max.above base 9.0 ft Applied Design Shear 0.0 psi Allowable Shear 272.0 psi Load Combination Results Maximum SERVICE Lateral Load Reactions.. Top along Y-Y 0.0 k Bottom along Y-Y 0.0 k Top along X-X 0.0 k Bottom along X-X 0.0 k Maximum SERVICE Load Lateral Deflections ... Along Y-Y 0,0 in at 0.0 ft abovebase for load combination: n/a Along XA 0.0 in at 0.0 It abovebase for load combination : n/a Other Factors used to calculate allowable stresses ... Bending Compression Tension Load Combination C D C P Maximum Axial + Bending Stress Ratio Status Stress Ratios Location D Only 0.900 0.788 0,1926 PASS 0.0 ft +D+S 1.150 0.715 0,3834 PASS 0.0 ft +D+0.750S 1.150 0.715 0.3291 PASS 0.0 ft +1.140D 1.600 0.596 0.1632 PASS 0.0 ft +1.105D+0,750S 1.600 0.596 0.2987 PASS 0.0 ft +0.60D 1.600 0.596 0,08588 PASS 0.0 ft +0.460D 1.600 0.596 0.06584 PASS 0.0 ft Maximum Shear Ratios Stress Ratio Status Location 0.0 PASS 9.0 ft 0.0 PASS 9.0 ft 0.0 PASS 9.0 ft 0.0 PASS 9.0 ft 0.0 PASS 9.0 ft 0.0 PASS 9.0 ft 0.0 PASS 9.0 ft WEI raw bud ow Wood Column File= SAJobs\s18\s1811\s1811020-917 Pine Streefto TB1203\181203 columns-enercalc trib s1811020.e ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.117.22A Description : (2-17) + (2-16)#2 + (1-22) Code References Calculations per NDS 2015, IBC 2015, CBC 2016,- ASCE 7-10 Load Combinations Used: I BC 2015 General Information Analysis Method: Allowable Stress Design Wood Section Name 6x6 End Fixities Top & Bottom Pinned Wood Grading/Manuf. Graded Lumber Overall Column Height 12.333 ft Wood Member Type Sawn ( Uspd for non -slender calculations Exact Width 5.50 in Allow Stress Modification Factors Wood Species Douglas Fir - Larch Exact Depth 5.50 in Cf or Cv for Bending 1.0 Wood Grade No.1 Area 30.25 in12 Cf or Cv for Compression 1.0 Fb - Tension 1,200.0 psi Fv 170.0 psi Ix 76.255 in14 Cf or Cv for Tension 1.0 Fb - Compr 1,200.0 psi Ft 825.0 psi ly 76.255 in14 Cm : Wet Use Factor 1.0 Fc - Pril 1,000.0 psi Density 31.20 pcf Ct : Temperature Factor 1.0 Fc - Perp 625.0 psi E : Modulus of Elasticity ... x-x Bending y-y Bending Axial Cfu : Flat Use Factor 1.0 Kf : Built-up columns 1.0 INIDS 15.3.2 Basic 1,600.0 1,600.0 1,600.0 ksi Use Cr: Repetitive ? No Minimum 580.0 580.0 Brace condition for deflection (buckling) along columns : X-X (width) axis: Unbraced Length for X-X Axis buckling = 12.333 It, K = 1.0 Y-Y (depth) axis: Unbraced Length for X-X Axis buckling = 12.333 ft, K = 1.0 Applied Loads Service loads entered. Load Factors will be applied for calculations. Column self weiqht included : 80.833 lbs * Dead Load Factor AXIAL LOADS. . . Axial Load at 12.333 ft, D = 6.377, L = 3.347, S = 6.219 k DESIGN SUMMARY Bending & Shear Check Results rAaa Max. MX01+13ending OLress Rauu 0.8121 :1 Maximum SERVICE Lateral Load Reactions.. Load Combination +D+0.750L+0.750S Top along Y-Y 0.0 k Bottom along Y-Y 0.0 k Governing NDS Forumla Comp Only, fc/Fc' Top along X-X 0.0 k Bottom along XA 0.0 k Location of max.above base 0.0 ft Maximum SERVICE Load Lateral Deflections ... At maximum location values are ... Along Y-Y 0.0 in at 0.0 It above base Applied Axial 13.632 k for load combination : n/a Applied Mx 0.0 k-ft Applied My 0.0 k-ft Along XA 0.0 in at 0.0 ft above base Fc: Allowable 554.95 psi for load combination : n/a Other Factors used to calculate allowable stresses ... PASS Maximum Shear Stress Ratio= 0.0 :1 Bending Compression Tension Load Combination +0.460D Location of max.above base 12.333 It Applied Design Shear 0.0 psi Allowable Shear 272.0 psi Load Combination Results Maximum Axial + Bendinq Stress Ratios Maximum Shear Ratios Load Combination C D C P Stress Ratio Status Location Stress Ratio Status Location D Only 0.900 0.576 0.4121 PASS 0.0 ft 0.0 PASS 12.333 Ift +D+L 1.000 0.535 0.6056 PASS 0.0 ft 0.0 PASS 12.333 ft +D+S 1.150 0.483 0.7552 PASS 0.0 ft 0.0 PASS 12.333 ft +D+0.750L+0.750S 1.150 0.483 0.8121 PASS 0.0 ft 0.0 PASS 12.333 ft +1.140D 1.600 0.369 0.4127 PASS 0.0 ft 0.0 PASS 12.333 ft +1.105D+0.750L+0.750S 1.600 0.369 0.8023 PASS 0.0 ft 0.0 PASS 12.333 ft +0.60D 1.600 0.369 0.2172 PASS 0.0 ft 0.0 PASS 12.333 ft +0.460D 1.600 0.369 0.1665 PASS 0.0 ft 0.0 PASS 12.333 ft WA File= S:Uobs\s18\s1811\s1811020 - 917 Pine Street\wo 181203\181203 columns-enerGaic trib_s I 811020.ed Wood Column ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.17.2.2f Lic. #: KW-06006655 Ui6ensee: SOUND STRUCTURAL SOLUTIO Description : (2-11) #2 Code References Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10 Load Combinations Used: IBC 2015 General Information Analysis Method Allowable Stress Design Wood Section Name 6x6 End Fixities Top & Bottom Pinned Wood Grading/Manuf. Graded Lumber Overall Column Height 9.0 ft Wood Member Type Sawn ( Used for non -slender calculatians Exact Width 5.50 in Allow Stress Modification Factors Wood Species Douglas Fir - Larch Exact Depth 5.50 in Cf or Cv for Bending 1.0 Wood Grade No.1 Area 30.25 in A 2 Cf or Cv for Compression 1.0 Fb - Tension 1,200.0 psi Fv 170.0 psi Ix 76.255 in A 4 Cf or Cv for Tension 1.0 Fb - Compr 1,200.0 psi Ft 825.0 psi ly 76.255 in A 4 Cm : Wet Use Factor 1.0 Fc - PrIl 1,000.0 psi Density 31.20 pcf Ct : Temperature Factor 1.0 Fc - Perp 625.0 psi Cfu : Flat Use Factor 1.0 E: Modulus of Elasticity ... x-x Bending y-y Bending Axial Kf : Built-up columns 1.0 NDS 15.3.2 Basic 1,600.0 1,600.0 1,600.0 ksi Use Cr: Repetitive ? No Minimum 580.0 580.0 Brace condition for deflection (buckling) along columns : X-X (width) axis: Unbraced Length for X-X Axis buckling = 9.0 ft, K = 1.0 Y-Y (depth) axis: Unbraced Length for XA Axis buckling = 9.0 ft, K = 1.0 Applied Loads Service loads entered. Load Factors will be applied for calculations. Column self weiqht included : 58.988 lbs * Dead Load Factor AXIAL LOADS ... Axial Load at 9.0 ft, D = 4.033, L = 5.256, S = 5.017 k DESIGN SUMMARY Bending & Shear Check Results PASS Max. Axial+Bending Stress Ratio Load Combination Governing NDS Forumla Location of max.above base At maximum location values are ... Applied Axial Applied Mx Applied My Fc: Allowable PASS Maximum Shear Stress Ratio= Load Combination Location of max.above base Applied Design Shear Allowable Shear Load Combination Results 0.4740 :1 +D+0.750L+0.750S Comp Only, fc/Fc' 0.0 ft 11.797 k 0.0 k-ft 0.0 k-ft 822.75 psi 0.0 :1 +0.460D 9.0 ft 0.0 psi 272.0 psi Maximum SERVICE Lateral Load Reactions.. Top along Y-Y 0.0 k Bottom along Y-Y 0.0 k Top along XA 0.0 k Bottom along X-X 0.0 k Maximum SERVICE Load Lateral Deflections ... Along Y-Y 0.0 in at 0.0 ft abovebase for load combination: n1a Along X-X 0.0 in at 0.0 ft above base for load combination : n/a Other Factors used to calculate allowable stresses ... Bending Compression Tension Load Combination C D C P Maximum Axial + Bending Stress Ratio Status Stress Ratios Location Maximum Shear Ratios Stress Ratio Status Location D Only 0.900 0.788 0.1907 PASS 0.0 ft 0.0 PASS 9.0 ft +D+L 1.000 0.759 0,4072 PASS 0.0 fit 0.0 PASS 9.0 ft +D+S 1.150 0.715 0.3660 PASS 0.0 ft 0.0 PASS 9.0 ft +D+0.750L+0.750S 1.150 0.715 0.4740 PASS 0.0 ft 0.0 PASS 9.0 ft +1.140D 1.600 0.596 0.1616 PASS 0.0 ft 0.0 PASS 9.0 ft +1.105D+0.750L+0.750S 1.600 0.596 0.4235 PASS 0.0 ft 0.0 PASS 9.0 ft +0.60D 1.600 0.596 0.08505 PASS 0.0 ft 0.0 PASS 9.0 ft +0.460D 1.600 0.596 0.06520 PASS 0.0 fit 0.0 PASS 9.0 ft OR 60 law OR 460 WWI Wood Column jMM. RTIM-IMM-13M Description : (2-11) #3 File= SAJobs\s18ks1811\s1811020-917 Pine Street\wo 131203\181203columns-enerralctrib_sl8llO2O.ec:I ENERCi1C, INC. 1983-2017, Build:6.17.2.28, Ver:6.17.2.2E Code References Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10 Load Combinations Used : IBC 2015 General Information Analysis Method Allowable Stress Design Wood Section Name 6x6 End Fixities Top & Bottom Pinned Wood Grading/Manuf. Graded Lumber Overall Column Height 9.0 ft Wood Member Type Sawn ( Used for non-siender calculations.) Wood Species Douglas Fir - Larch Exact Width 5.50 in Allow Stress Modification Factors Wood Grade No.1 Exact Depth 5.50 in Cf or Cv for Bending 1.0 Fb - Tension 1,200.0 psi Fv 170.0 psi Area 30.25 in'12 Cf or Cv for Compression 1.0 Fb - Compr 1,200.0 psi Ft 825.0 psi Ix 76.255 in,14 Cf or Cv for Tension 1.0 Fe - PrIl 1,000.0 psi Density 31.20 pcf ly 76.255 inA4 Cm: Wet Use Factor 1.0 Fc - Perp 625.0 psi Ct : Temperature Factor 1.0 E : Modulus of Elasticity ... x-x Bending y-y Bending Axial Cfu : Flat Use Factor 1.0 Kf: Built-up columns 1.0 NDSI,5�3.2 Basic 1,600.0 1,600.0 1,600.0 ksi Use Cr : Repetitive ? No Minimum 580.0 580.0 Brace condition for deflection (buckling) along columns : X-X (width) axis: Unbraced Length for X-X Axis buckling = 9.0 ft, K = 1.0 Y-Y (depth) axis: Unbraced Length for X-X Axis buckling = 9.0 ft, K = 1.0 Applied Loads Service loads entered. Load Factors will be applied for calculations. Column self weiqht included : 58.988 lbs * Dead Load Factor AXIAL LOADS ... Axial Load at 9.0 ft, D = 4.106, L = 7.921, S = 5.293 k DESIGN SUMMARY Bending & Shear Check Results PASS Max. Axia]+Bending Stress Ratio 0.5655 :1 Maximum SERVICE Lateral Load Reactions.. Load Combination +D+0,750L+0.750S Top along Y-Y 0.0 k Bottom along Y-Y 0.0 k Governing NDS Forumla Comp Only, fc/Fc' Top along X-X 0.0 k Bottom along X-X 0.0 k Location of max.above base 0.0 ft Maximum SERVICE Load Lateral Deflections ... At maximum location values are ... Along Y-Y 0.0 in at 0.0 ft above base Applied Axial 14.075 k for load combination : n/a Applied Mx 0.0 k-ft Applied My 0.0 k-ft Along X-X 0.0 in at 0.0 ft above base Fc: Allowable 822.75 psi for load combination : n/a Other Factors used to calculate allowable stresses ... PASS Maximum Shear Stress Ratio 0.0 :1 Bending Compression Tension Load Combination +0.460D Location of max.above base 9.0 ft Applied Design Shear 0.0 psi Allowable Shear 272.0 psi Load Combination Results ow Maximum Axial + Bendinq Stress Ratios Maximum Shear Ratios Load Combination C D C P Stress Ratio Status Location Stress Ratio Status Location 00 D Only 0.900 0.788 0.1941 PASS 0.0 ft 0.0 PASS 9.0 ft +D+L 1.000 0.759 0.5265 PASS 0.0 ft 0.0 PASS 9.0 ft 6W +D+S 1.150 0.715 0.380 PASS 0.0 ft 0.0 PASS 9.0 ft +D+0.750L+0.750S 1.150 0.715 0.5655 PASS 0.0 ft 0.0 PASS 9.0 ft +1.140D 1.600 0.596 0.1645 PASS 0.0 ft 0.0 PASS 9.0 ft +1.105D+0.750L+0.750S 1.600 0.596 0.5027 PASS 0.0 ft 0.0 PASS 9.0 ft +0.60D 1.600 0.596 0.08656 PASS 0.0ft 0.0 PASS 9.0 ft +0.460D 1.600 0.596 0.06637 PASS 0.0 ft 0.0 PASS 9.0 ft File= SAJobs\s18Ns1811\s1811020 - 917 Pine Streeko 181203\181203 columnsenerealc trib - s1811020.ed Wood Column ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.17.2.2E . # - KW-06006655 Licensee: SOUND STRUCTURAL SOLUTIONZ Description : WIND COLUMNS AT ENTRY Code References Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10 Load Combinations Used: ASCE 7-10 General Information Analysis Method Allowable Stress Design Wood Section Name 5.25x5.25 End Fixities Top Fixed, Bottom Fixed Wood Grading/Manuf. Trus Joist Overall Column Height 19.0 ft Wood Member Type Parallam PSL ( Used for non -slender calculatians Exact Width 5.250 in Allow Stress Modification Factors Wood Species Trus Joist Exact Depth 5.250 in Cf or Cv for Bending 1.0 Wood Grade Parallam PSL 2.21E Area 27.563 in12 Cf or Cv for Compression 1.0 Fb - Tension 2900 psi Fv 290 psi Ix 63.308 in14 Cf or Cv for Tension 1.0 Fb - Compr 2900 psi Ft 2025 psi ly 63.308 in A 4 Cm : Wet Use Factor 1.0 Fc - PrIl 2900 psi Density 45.05 pcf Ct: Temperature Factor 1.0 Fc - Perp 625 psi Cfu : Flat Use Factor 1.0 E : Modulus of Elasticity ... x-x Bending y-y Bending Axial Kf : Built-up columns 1.0 NDS 15,31 Basic 2200 2200 2200 ksi Use Cr : Repetitive ? No Minimum 1118.19 1118.19 Qr ­44;nn fnr finfl-f- lik"Adin � ninn Pni"mne v - I U �1 X-X (width) axis: Fully braced against buckling along X-X Axis Y-Y (depth) axis: Fully braced against buckling along Y-Y Axis Applied Loads Service loads entered. Load Factors will be applied for calculations. Column self weiqht included : 163.837 lbs * Dead Load Factor AXIAL LOADS ... Axial Load at 19.0 ft, D = 0.50, S = 0.6250 k BENDING LOADS ... Lat. Uniform Load creatinq Mx-x, W = 0.0840 k/ft DESIGN SUMMARY Bending & Shear Check Results PASS Max. Axia]+Bending Stress Ratio 0.1626 :1 Maximum SERVICE Lateral Load Reactions.. Load Combination +D+0.60W+H Top along Y-Y 0.7980 k Bottom along Y-Y 0.7980 k Governing NOS Forumla Comp + Mxx, NDS Eq. 3.9-3 Top along XA 0.0 k Bottom along XA 0.0 k Location of max.above base 0.0 ft Maximum SERVICE Load Lateral Deflections ... At maximum location values are ... Along Y-Y 0.3537 in at 9.564 ft abovebase Applied Axial 0.6638 k for load combination: W Only Applied Mx -1.516 k-ft Along X-X 0.0 in at 0.0 ft abovelbase Applied My 0.0 k-ft Fc: Allowable 4,640.0 psi for load combination : n/a Other Factors used to calculate allowable stresses ... PASS Maximum Shear Stress Ratio= 0.03744:1 Bending Compression Tension Load Combination +D+0.60W+H Location of max.above base 19.0 ft Applied Design Shear 26.057 psi Allowable Shear 464.0 psi Load Combination Results Maximum Axial + Bending Stress Ratios Maximum Shear Ratios Load Combination C D C P Stress Ratio Status Location Stress Ratio Status Location +D+H 0.900 1.000 0.009228 PASS 0.0 ft 0.0 PASS 19.0 ft +D+L+H 1.000 1.000 0.008305 PASS 0.0 ft 0.0 PASS 19.0 ft +D+Lr+H 1.250 1.000 D.006644 PASS 0.0ft 0.0 PASS 19.0 ft +D+S+H 1.150 1.000 0.01402 PASS 0.0 ft 0.0 PASS 19.0 ft +D+0.750Lr+0.750L+H 1.250 1.000 D.006644 PASS 0.0 ft 0.0 PASS 19.0 ft +D+0.750L+0.750S+H 1.150 1.000 0.01232 PASS 0.0 ft 0.0 PASS 19.0 ft +D+0.60W+H 1.600 1.000 0.1626 PASS 0.0 ft 0.03744 PASS 19.0 ft +D+0.70E+H 1.600 1.000 D.005191 PASS 0.0ft 0.0 PASS 19.0 ft +D+0.750Lr+0.750L+0.450W+H 1.600 1.000 0.1220 PASS 0.0 ft 0.02808 PASS 19.0 ft am aw 04 0" AMR Wood Column Description : VVIND COLUMNS AT ENTRY Load Combination Results S.1Jabs\s18\s1811\s11811020 - 917 Pine Streetwo 161203\181203 columns�_enercalc trib_0811020.ed ENIERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.17.22t Maximum Axial + Bending Stress Ratios Maximum Shear Ratios Load Combination C D C P Stress Ratio Status Location Stress Ratio Status Location +D+0.750L+0.750S+0.450W+H 1.600 1.000 0.1220 PASS 0.0 ft 0.02808 PASS 19.0 It +D+0.750L+0.750S+0.5250E+H 1.600 1.000 0.008856 PASS 0.0 ft 0.0 PASS 19.0 it +0.60D+0.60W+0.60H 1.600 1.000 0.1626 PASS 0.0ft 0.03744 PASS 19.0 It +0.60D+0.70E+0.60H 1.600 1.000 0.003114 PASS O.Oft 0.0 PASS 19.0 it Iwo 04 File= S:Uobs\s18\s1811\s1811020 -917 Pine Streetwo 181203\181203 columns-enerGalctrib_0811020.ed Wood Column ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.17.2.2E Lic. # ; KW-06006655 Licensee: SOUND STRUCTURAL SOLUTIONZ Description : WIND COLUMNS AT ENTRY - BETWEEN WINDOWS Code References Calculations per INDS 2015, 1 BC 2015, CBC 2016, ASCE 7-10 Load Combinations Used: ASCE 7-10 General Information Analysis Method Allowable Stress Design Wood Section Name 3.5x5.25 End Fixities Top Fixed, Bottom Fixed Wood Grading/Manuf. Trus Joist Overall Column Height 19.0 ft Wood Member Type Parallam PSL ( Used for non -slender calculations Exact Width 3.50 in Allow Stress Modification Factors Wood Species Trus Joist Exact Depth 5.250 in Cf or Cv for Bending 1.0 Wood Grade Parallam PSL 2.2E Area 18.375 in A 2 Cf or Cv for Compression 1.0 Fb - Tension 2,900.0 psi Fv 290.0 psi Ix 42.205 in14 Cf or Cv for Tension 1.0 Flb - Compr 2,900.0 psi Ft 2,025.0 psi ly 18.758 inA4 Cm : Wet Use Factor 1.0 Fc - PrIl 2,900.0 psi Density 45.050 pcf Ct : Temperature Factor 1.0 Fc - Perp 625.0 psi Cfu : Flat Use Factor 1.0 E : Modulus of Elasticity ... x-x Bending y-y Bending Axial Kf : Built-up columns 1 . 0 NDS 15,3.2 Basic 2,200.0 2,200.0 2,200.0 ksi Use Cr : Repetitive ? No Minimum 1,118.19 1,118.19 Brace condition for deflection lbucklinnl alonn columns : aw 111" ftw Applied Loads X-X (width) axis: Fully braced against buckling along XA Axis Y-Y (depth) axis: Fully braced against buckling along Y-Y Axis Service loads entered. Load Factors will be applied for calculations. Column self weiqht included : 109.223 Ibs * Dead Load Factor AXIAL LOADS ... Axial Load at 19.0 ft, D = 0.50, S = 0.6250 k BENDING LOADS ... Lat. Uniform Load creatinq Mx-x, W = 0.0840 k/fit DESIGN SUMMARY Bending & Shear Check Results PASS Max. Axial+Bending Stress Ratio 0.2439 :1 Maximum SERVICE Lateral Load Reactions.. Load Combination +D+0.60W+H Top along Y-Y 0.7980 k Bottom along Y-Y 0.7980 k Governing NOS Forumla Comp + Mxx, NDS Eq. 3.9-3 Top along X-X 0.0 k Bottom along X-X 0.0 k Location of max.above base 0.0 ft Maximum SERVICE Load Lateral Deflections ... At maximum location values are ... Along Y-Y 0.5306 in at 9.564 ft abovebase PR Applied Axial 0.6092 k for load combination : W Only Applied Mx -1.516 k-ft Applied My 0.0 k-ft Along X-X 0.0 in at 0.0 ft above base Fc: Allowable 4,640.0 psi for load combination : n/a Other Factors used to calculate allowable stresses ... PASS Maximum Shear Stress Ratio 0.05616 :1 Bending Compression Tension Load Combination +D+0.60W+H Location of max.above base 19.0 ft Applied Design Shear 39.086 psi Allowable Shear 464.0 psi Load Combination Results Load Combination C D C P Maximum Axial + Bending Stress Ratio Status Stress Ratios Location Maximum Shear Ratios Stress Ratio Status Location +D+H 0.900 1.000 0.01270 PASS 0.0 ft 0.0 PASS 19.0 ft +D+L+H 1.000 1.000 0.01143 PASS 0.0 ft 0.0 PASS 19.0 ft +D+Lr+H 1.250 1.000 0.009146 PASS 0.0 fit 0.0 PASS 19.0 ft +D+S+H 1.150 1.000 0.02014 PASS 0.0 ft 0.0 PASS 19.0 ft +D+0.750Lr+0.750L+H 1.250 1.000 0.009146 PASS 0.0 ft 0.0 PASS 19.0 ft +D+0.750L+0.750S+H 1.150 1.000 0.01759 PASS 0.0 it 0.0 PASS 19.0 ft +D+0.60W+H 1.600 1.000 0.2439 PASS 0.0 ft 0.05616 PASS 19.0 ft +D+0.70E+H 1.600 1.000 D.007145 PASS O�O ft 0.0 PASS 19.0 ft +D+0.75OLr+0.750L+0.450W+H 1.600 1.000 0.1830 PASS 0.0 ft 0.04212 PASS 19.0 ft ON me PIN L I amp PIR 'Nood Column S:\JobsAs18Xs1811Xs1811020- 917 Pine Streetkwo 11203\1811203 colurnns�enercalc trIb_s1811020.ec1 ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.17.22f Description : WIND COLUMNS AT ENTRY - BETWEEN WINDOWS Load Combination Results Maximum Axial + Sending Stress Ratios Maximum Shear Ratios Load Combination C D C P Stress Ratio Status Location Stress Ratio Status Location +D+0.750L+0.750S+0.450W+H 1.600 1.000 0.1831 PASS 0.0 ft 0.04212 PASS 19.0 it +D+0.750L+0.750S+0.5250E+H 1.600 1.000 0.01264 PASS O.Oft 0.0 PASS 19.0 it +0.60D+0.60W+0.60H 1.600 1.000 0.2439 PASS 0.0 it 0.05616 PASS 19.0 it +0.60D+0.70E+0.60H 1.600 1.000 0.004287 PASS 0.0 it 0.0 PASS 19.0 it File= S:\Jobs\s18ks1811\s1811020 -917 Pine Streefto 181203\181203 columnsenercalc trlb_s1811020.ec( Wood Column ENERCALC, INC. 1983-2017, Build:6,17.2.28, Ver:6.17.2.2E Lic. # : KW-06006655 Licensee: SOUND STRUCTURAL SOLUTION," Description : (1-18) + (1-19) + (1-20) (PACKED STUDS) P" Code References Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10 Load Combinations Used: ASCE 7-10 General Information Analysis Method Allowable Stress Design Wood Section Name 6x6 End Fixities Top Fixed, Bottom Fixed Wood Grading/Manuf. Graded Lumber Overall Column Height 10.0 ft Wood Member Type Sawn ( Used for non-sbender calculations Exact Width 5.50 in Allow Stress Modification Factors Wood Species Douglas Fir - Larch Exact Depth 5.50 in Cf or Cv for Bending 1.0 Wood Grade No.2 Area 30.25 in12 Cf or Cv for Compression 1.0 Fb - Tension 900.0 psi Fv 180.0 psi Ix 76.255 in14 Cf or Cv for Tension 1.0 Fb - Compr 900.0 psi Ft 575.0 psi ly 76.255 inA4 Cm : Wet Use Factor 1'0 Fc - PrIl 1,350.0 psi Density 31.20 pcf Ct: Temperature Factor 1.0 Fc - Perp 625.0 psi Cfu : Flat Use Factor 1.0 E : Modulus of Elasticity ... x-x Bending y-y Bending Axial Kf: Built-up columns 1.0 NDS 15 3.2 Basic 1,600.0 1,600.0 1,600.0 ksi Use Cr: Repetitive ? No Minimum 580.0 580.0 Brace condition for deflection (buckling) along columns : X-X (width) axis: Fully braced against buckling along X-X Axis Y-Y (depth) axis: Fully braced against buckling along Y-Y Axis Loads Service loads entered. Load Factors will be applied for calculations. -Applied Column self weiqht included : 65.542 lbs * Dead Load Factor AXIAL LOADS. . . on Axial Load at 10.0 ft, D = 5.190, L 3.0, S = 4.240 k we DESIGN SUMMARY Bending & Shear Check Results OR PASS Max. Axia]+Bending Stress Ratio 0.2275:1 Maximum SERVICE Lateral Load Reactions.. Load Combination +D+0.750L+0.750S+H Top along Y-Y 0.0 k Bottom along Y-Y 0.0 k Governing NDS Forumla Comp Only, fc/Fc' Top along XA 0.0 k Bottom along X-X 0.0 k Location of max.above base 0.0 ft Maximum SERVICE Load Lateral Deflections ... At maximum location values are ... Along Y-Y 0.0 in at 0.0 ft above base Applied Axial 10.686 k for load combination : n/a Applied Mx 0.0 k-ft Applied My 0.0 k-ft Along X-X 0.0 in at 0.0 ft above base Fc: Allowable 1,552.50 psi for load combination : n/a Other Factors used to calculate allowable stresses ... PASS Maximum Shear Stress Ratio 0.0 : 1 Bendinq Compression Tension Load Combination +0.60D+0.70E+0.60H Location of max.above base 10.0 ft Applied Design Shear 0.0 psi Allowable Shear 288.0 psi Load Combination Results Load Combination C D C P Maximum Axial + Bending Stress Ratio Status Stress Ratios Location Maximum Shear Ratios Stress Ratio Status Location +D+H 0.900 1.000 0.1430 PASS 0.0ft 0.0 PASS 10.0 ft +D+L+H 1.000 1.000 0.2022 PASS 0.0 ft 0.0 PASS 10.0 ft +D+Lr+H 1.250 1.000 0.1030 PASS 0.0 ft 0.0 PASS 10.0 ft +D+S+H 1.150 1.000 0.2022 PASS 0.0 ft 0.0 PASS 10.0 ft +D+0,750Lr+0.750L+H 1.250 1.000 0.1470 PASS 0.0 ft 0.0 PASS 10.0 ft +D+0.750L+0.750S+H 1.150 1.000 0.2275 PASS 0.0 ft 0.0 PASS 10.0 ft +D+0.60W+H 1 �600 1.000 0.08043 PASS 0.0 ft 0.0 PASS 10.0 ft +D+0.70E+H 1.600 1.000 0.08043 PASS 0.0ft 0.0 PASS 10.0 ft +D+0.750Lr+0,750L+0.450W+H 1.600 1.000 0.1149 PASS 0.0ft 0.0 PASS 10.0 ft +D+0.750L+0.750S+0.450W+H 1.600 1.000 0.1635 PASS 0.0ft 0.0 PASS 10.0 ft +D+0.750L+0.750S+0.5250E+H 1.600 1.000 0.1635 PASS 0.0 ft 0.0 PASS 10.0 ft +0.60D+0.60W+0.60H 1.600 1.000 0.04826 PASS 0.0 ft 0.0 PASS 10.0 ft Wood Column . .1c. #: KW-06006655 DescrIption : (1-18) + (1-19) + (1-20) (PACKED STUDS) Load Combination Results File= S:�Jobs\s%Ml %1811020 - 917 Pine Streeftwo V1201181203 columns,_enercalc tdbjl8llO2O.ec( ENERCALC, INC. 1983-2017, Build:6.17.2.28. Ver:6.17.22i Maximum Axial + Bending Stress Ratios Maximum Shear Ratios Load Combination C D c p Stress Ratio Status Location Stress Ratio Status Location +0.60D+0.70E+0.60H 1.600 1.000 0.04826 PASS 0.0 ft 0.0 PASS 10.0 It 04 File= S:Wbs\s18\s181Ps1811020-917 Pine StreOwo 181203\181203 columns-enercalctrib-sl8ll02O.ed Steel Column ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.17.2.2E 'Lic. #: KW-06006655 Licensee: SOUND STRUCTURAL SOLUTIONS Description : (1-7) #2 + (2-11) #2, UNBRACED 10'3" Code References Calculations per AISC 360-10, IBC 2015, CBC 2016, ASCE 7-10 Load Combinations Used: ASCE 7-10 General Information Steel Section Name: HSS3x3x5/16 Overall Column Height 10.250 ft Analysis Method: Allowable Strength Top & Bottom Fixity Top & Bottom Pinned Steel Stress Grade Brace condition for deflection (buckling) along columns Fy : Steel Yield 36.0 ksi X-X (width) axis: E : Elastic Bending Modulus 29,000.0 ksi Fully braced against buckling along X-X Axis Y-Y (depth) axis: Fully braced against buckling along Y-Y Axis Applied Loads Service loads entered. Load Factors will be applied for calculations. Column self weight included : 108.445 lbs * Dead Load Factor AXIAL LOADS ... Axial Load at 10.250 It, D = 11.877, L = 12.444, S = 8.230 k BENDING LOADS.. . Lat. Point Load at 10.0 ft creating Mx-x, E = 1.636 k DESIGN SUMMARY Bending & Shear Check Results PASS Max. Axial+Bending Stress Ratio 0.4694 : 1 Maximum SERVICE Load Reactions.. Load Combination +D+0.750L+0.750S+0.5250E+H Top along X-X 0.0 k Location of max.above base 9.975 ft Bottom along X-X 0.0 k At maximum location values are ... Top along Y-Y 1.596 k Pa Axial 27.491 k Bottom along Y-Y 0.03990 k Pn Omega: Allowable 63.377 k Ma-x: Applied 0.2090 k-ft Maximum SERVICE Load Deflections ... Mn-x / Omega: Allowable 5.210 k-ft Along Y-Y 0.04798 in at 5.916ft above base for load combination: E Only Ma-y: Applied 0.0 k-ft Mn-y / Omega: Allowable 5.210 k-ft Along X-X 0.0 in at O.Oft above base for load combination PASS Maximum Shear Stress Ratior 0.06978 : I Load Combination +D+0.70E+H Location of max.above base 10.044 ft At maximum location values are ... Va: Applied 1.117 k Vn /Omega: Allowable 16.011 k Load Combination Results Load Combination Maximum Axial + Bending Stress Ratio Status Stress Ratios Location Maximum Shear Ratios Stress Ratio Status Location +D+H 0.189 PASS 0.00 ft 0.000 PASS 0.00 ft +D+L+H 0.385 PASS 0.00 ft 0.000 PASS 0.00 ft +D+Lr+H 0.189 PASS 0.00 ft 0.000 PASS 0.00 ft +D+S+H 0.319 PASS 0.00 ft 0.000 PASS 0.00 ft +D+0.75OLr+0,750L+H 0.336 PASS 0.00 ft 0.000 PASS 0.00 ft +D+0.750L+0.750S+H 0.434 PASS 0.00 ft 0.000 PASS 0.00 ft +D+0.60W+H 0.189 PASS 0.00 ft 0.000 PASS 0.00 ft +D+0.70E+H 0.189 PASS 0.00 ft 0.070 PASS 10.04 ft +D+0.75OLr+0.750L+0.450W+H 0.336 PASS 0.00 ft 0.000 PASS 10.04 ft +D+0.750L+0.750S+0.450W+H 0.434 PASS 0.00 ft 0.000 PASS 10.04 ft +D+0.750L+0.750S+0.5250E+H 0.469 PASS 9.97 ft 0.052 PASS 10.04 ft +0.60D+0.60W+0.60H 0.113 PASS 0.00 ft 0.000 PASS 10.04 ft +0.60D+0.70E+0.60H 0.113 PASS 0.00 ft 0.070 PASS 10.04 ft Steel Column File= S:\Jobs'vs18IsI8Ms1811020 - 917 Pine Streeftwo 181203\181203 columns enercalctrib sl&1102 I ' ';' �111-ic. ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver6.1772j # : KW-06006655 Licensee-, SOUND STRUCTURAL SOWTI(s Description : (1-7) #2 + (2-11) #2, UNBRACED 10'3" Maximum Reactions Note: Only non -zero reactions are listed. X-X Axis Reaction Y-Y Axis Reaction Axial Reaction Load Combination @ Base @ Top @ Base @ Top @ Base +D+H k k 11.985 k +D+L+H k k 24.429 k +D+Lr+H k k 11.985 k +D+S+H k k 20.215 k +D+0.750Lr+0.750L+H k k 21.318 k +D+0.750L+0.750S+H k k 27.491 k +D+0.60W+H k k 11.985 k +D+0.70E+H k 0,028 1.117 k 11.985 k +D+0.75OLr+0.750L+0.450W+H k k 21.318 k +D+0.750L+0.750S+0.450W+H k k 27.491 k +D+0.750L+0.750S+0.5250E+H k 0.021 0.838 k 27.491 k +0.60D+0.60W+0.60H k k 7.191 k +0.60D+0.70E+0.60H k 0.028 1.117 k 7.191 k D Only k k 11.985 k Lr Only k k k L Only k k 12.444 k S Only k k 8.230 k W Only k k k E Only k 0.040 1.596 k k H Only k k k Maximum Deflections for Load Combinations Load Combination Max. X-X Deflection Distance Max. Y-Y Deflection Distance +D+H 0.0000 in 0.000 Ift 0.000 in 0.000 ft +D+L+H 0.0000 in 0.000 ft 0.000 in 0.000 ft +D+Lr+H 0.0000 in 0.000 ft 0.000 in 0.000 ft +D+S+H 0.0000 in 0.000 ft 0.000 in 0.000 ft +D+0.750Lr+0.750L+H 0.0000 in 0.000 ft 0.000 in 0.000 ft +D+0.750L+0.750S+H 0.0000 in 0.000 ft 0.000 in 0.000 ft +D+0.60W+H 0.0000 in 0.000 ft 0.000 in 0.000 ft +D+0.70E+H 0.0000 in 0.000 ft 0.034 in 5.916 ft +D+0.750Lr+0.750L+0.450W+H 0.0000 in 0.000 ft 0.000 in 0.000 ft +D+0.750L+0.750S+0.450W+H 0.0000 in 0.000 ft 0.000 in 0.000 ft +D+0.750L+0.750S+0.5250E+H 0.0000 in 0.000 ft 0.025 in 5.916 ft +0.60D+0.60W+0.60H 0.0000 in 0.000 ft 0.000 in 0.000 ft +0.60D+0.70E+0.60H 0.0000 in 0.000 ft 0.034 in 5.916 ft D Only 0.0000 in 0.000 ft 0.000 in 0.000 ft Lr Only 0.0000 in 0.000 ft 0.000 in 0.000 ft L Only 0.0000 in 0.000 ft 0.000 in 0.000 ft S Only 0.0000 in 0.000 ft 0.000 in 0.000 ft W Only 0.0000 in 0.000 ft 0.000 in 0.000 ft E Only 0.0000 in 0.000 ft 0.048 in 5.916 ft H Only 0.0000 in 0.000 ft 0.000 in 0.000 ft Steel Section Properties HSS3x3x5/16 Steel Column File= S:\Jobs\s181s1811\s1811020 - 917 Pine Streetwo 181203\181203 cDlurnns�_enercalc trlb_s181I020.ecl . ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.17.2.2E Lic. # : KW-06006655 Licensee: SOUND STRUCTURAL SOLUTIONS Description : (1-7) #2 + (2-11) #2, UNBRACED 10'3" Steel Section Properties IHSS3x3x5/16 Depth 3.000 in I xx 3.45 inA4 1 5.940 in A 4 Design Thick '6.291 in S xx 2.30 in'13 Width 3.000 in R xx 1.080 in Wall Thick 0.313 in zx 2.900 in13 Area 2.9* in A 2 1 yy 3.450 inA4 C 4.180 in A 3 Weight 10.580. Pif S yy 2.300 in A 3 R yy 1.080 in Ycg 0.000 in M-x Loads x Loads are total entered value. Arrows do not reflect absolute direction. I INood Column Description (1-22) File = S.Uobs\s18\s181 %1811020 - 917 Pine Streetkwo 161203\181203 colurrins-enercalc trib - s18111 ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6. Code References Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10 Load Combinations Used: IBC 2015 General Information Analysis Method Allowable Stress Design End Fixities Top & Bottom Pinned Overall Column Height 11.750 ft ( Used for non -slender calculations ) Wood Section Name 4x6 Wood Grading/Manuf. Graded Lumber Wood Member Type Sawn Wood Species Douglas Fir - Larch Exact Width 3.50 in Allow Stress Modification Factors Wood Grade No.2 Exact Depth 5.50 in Cf or Cv for Bending 1.30 Fb - Tension 900.0 psi Fv 180.0 psi Area 19.250 in A 2 Cf or Cv for Compression 1.10 Fib - Compr 900.0 psi Ft 575.0 psi Ix 48.526 inA4 Cf or Cv for Tension 1.30 Fe - PrIl 1,350.0 psi Density 31.20 pcf ly 19.651 inA4 Cm : Wet Use Factor 1.0 Fc - Perp 625.0 psi Ct : Temperature Factor 1.0 E : Modulus of Elasticity ... x-x Bending y-y Bending Axial Cfu : Flat Use Factor 1.0 Kf : Built-up columns 1 . 0 PVD;S 15.3.2 Basic 1,600.0 1,600.0 1,600.0 ksi Use Cr : Repetitive ? No Minimum 580.0 580.0 Brace condition for deflection (buckling) along columns : X-X (width) axis: Fully braced against buckling along X-X Axis Y-Y (depth) axis: Unbraced Length for X-X Axis buckling = 11.750 ft, K = 1.0 Applied Loads Service loads entered. Load Factors will be applied for calculations. Column self weiqht included : 49.007 lbs * Dead Load Factor AXIAL LOADS ... bw Axial Load at 11.750 ft, D = 2.750, L = 3.504, S = 1.730 k DESIGN SUMMARY Bending & Shear Check Results PASS Max. Axial+Bending Stress Ratio 0.5423 :1 Maximum SERVICE Lateral Load Reactions.. Load Combination +1.1 05D+0.750L+0.750S Top along Y-Y 0.0 k Bottom along Y-Y 0.0 k Governing NDS Forumla Comp Only, fc/Fc' Top along X-X 0.0 k Bottom along X-X 0.0 k Location of max.above base 0.0 ft Maximum SERVICE Load Lateral Deflections ... 6W At maximum location values are ... Along Y-Y 0.0 in at 0.0 ft above base Applied Axial 7.018 k for load combination : n/a Applied Mx 0.0 k-ft Applied My 0.0 k-ft Along XA 0.0 in at 0.0 ft abovebase 6w Fc: Allowable 672.35 psi for load combination : n/a Other Factors used to calculate allowable stresses ... PASS Maximum Shear Stress Ratio= 0.0 :1 Bending Compression Tension OR Load Combination +0.460D Location of max.above base 11.750 ft Applied Design Shear 0.0 psi Allowable Shear 288.0 psi Load Combination Results Maximum Axial + Bending Stress Ratios Maximum Shear Ratios Load Combination C D C P Stress Ratio Status Location Stress Ratio Status Location 00 D Only 0.900 0.463 0.2350 PASS O.Oft 0.0 PASS 11.750 ft i, +D+L 1.000 0.425 0.5182 PASS O.Oft 0.0 PASS 11.750 ft 6w +D+S 1.150 0.379 0.3639 PASS 0.0 ft 0.0 PASS 11.750 ft +D+0.750L+0,750S 1.150 0.379 0.5402 PASS 0.0 ft 0.0 PASS 11.750 ft +1.140D 1.600 0.283 0.2465 PASS 0.0 ft 0.0 PASS 11.750 ft +1. 1 05D+0.750L+0.750S 1.600 0.283 0.5423 PASS 0.0 ft 0.0 PASS 11.750 ft +0.60D 1.600 0.283 0.1298 PASS 0.0 ft 0.0 PASS 11.750 ft +0.460D 1.600 0.283 0.09948 PASS 0.0 ft 0.0 PASS 11.750 ft P" E__1 F__j "o File= SAJobs\sl8ks1811\s1811020-917 Pine Streeftwo 181203�181203 columns-enercalctdb-sl8llO2O.ecI Wood Column ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.1722E Description : (1-13) #2 Code References Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10 Load Combinations Used: I BC 2015 General Information Analysis Method: Allowable Stress Design End Fixities Top & Bottom Pinned Overall Column Height 9.250 ft ( Used for non -slender calcu'lations Wood Species Douglas Fir - Larch Wood Grade No.2 Flb - Tension 900.0 psi Fv 180.0 psi Fb - Compr 900.0 psi Ft 575.0 psi Fc - PrIl 1,350.0 psi Density 31.20 pcf Fc - Perp 625.0 psi E : Modulus of Elasticity ... x-x Bending y-y Bending Basic 1,600.0 1,600.0 Minimum 580.0 580.0 Applied Loads Column self weiqht included 24.551 lbs * Dead Load Factor AXIAL LOADS ... Axial Load at 9.250 ft, D 0.6670, S = 0.8340 k DESIGN SUMMARY Bending & Shear Check Results PASS Max. Axia]+Bending Stress Ratio Load Combination Governing NDS Forumla Location of maxabove base At maximum location values are., . Applied Axial Applied Mx Applied My Fc: Allowable PASS Maximum Shear Stress Ratio Load Combination Location of max.above base Applied Design Shear Allowable Shear Load Combination Results Load Combination D Only +D+S +D+0.750S +1.140D +1.105D+0.750S +0.60D +0.460D Wood Section Name 4x4 Wood Grading/Manuf. Graded Lumber Wood Member Type Sawn Exact Width 3.50 in Allow Stress Modification Factors Exact Depth 3.50 in Cf or Cv for Bending 1.50 Area 12.25 in12 Cf or Cv for Compression 1.150 Ix 12.505 in14 Cf or Cv for Tension 1.50 ly 12.505 inA4 Cm : Wet Use Factor 1.0 Ct : Temperature Factor 1.0 Cfu : Flat Use Factor 1.0 Axial Kf: Built-up columns 1.0 NDS 15.3.2 1,600.0 ksi Use Cr: Repetitive ? No Brace condition for deflection (buckling) along columns : X-X (width) axis : Unbraced Length for X-X Axis buckling = 9.250 ft, K = 1.0 Y-Y (depth) axis: Unbraced Length for X-X Axis buckling = 9.250 ft, K = 1.0 Service loads entered. Load Factors will be applied for calculations. 0.2801 :1 +D+S Comp Only, fc/Fc' 0.0 ft 1.526 k 0.0 k-ft 0.0 k-ft 444.537 psi 0.0 :1 +0.460D 9.250 ft 0.0 psi 288.0 psi Maximum SERVICE Lateral Load Reactions.. Top along Y-Y 0.0 k Bottom along Y-Y 0.0 k Top along X-X 0.0 k Bottom along X-X 0.0 k Maximum SERVICE Load Lateral Deflections ... Along Y-Y 0.0 in at 0.0 ft abovebase for load combination: n/a Along X-X 0,0 in at 0.0 ft above base for load combination : n/a Other Factors used to calculate allowable stresses ... Sending Como ssion Tension C D C P Maximum Axial + Bendinq Stress Ratio Status Stress Ratios Location 0.900 0.311 0.1299 PASS 0.0ft 1.150 0.249 0.2801 PASS 0.0 ft 1.150 0.249 0.2419 PASS 0.0 ft 1.600 0.183 0.1418 PASS 0.0 ft 1.600 0.183 0.250 PASS 0.0 ft 1.600 0.183 0.07465 PASS 0�oft 1.600 0.183 0.05723 PASS 0.0 ft Maximum Shear Ratios Stress Ratio Status Location 0.0 PASS 9.250 ft 0.0 PASS 9.250 ft 0.0 PASS 9.250 ft 0.0 PASS 9.250 ft 0.0 PASS 9.250 ft 0.0 PASS 9.250 ft 0.0 PASS 9.250 ft Wood Column File= S:\Jobs\sl8\sl8l %18111020- 917 Pine Streetwo 11203\181203 oolumns-enercalctdb-sl8ll02O.eiI ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver(3.117.2.2f Description : (2-10) + (2-14) Code References Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10 Load Combinations Used: IBC 2015 General Information Analysis Method Allowable Stress Design End Fixities Top & Bottom Pinned Overall Column Height 9.0 ft Usedfor non -slender calculations Wood Species Douglas Fir - Larch Wood Grade No.2 Flb - Tension 900.0 psi Fv 180.0 psi Fb - Compr 900.0 psi Ft 575.0 psi Fe - PrII 1,350.0 psi Density 31.20 pcf Fe - Perp 625.0 psi E : Modulus of Elasticity ... x-x Bending y-y Bending Basic 1,600.0 1,600.0 Minimum 580.0 580.0 Applied Loads Column self wei.qht included : 23.888 lbs * Dead Load Factor AXIAL LOADS ... Axial Load at 9.0 ft, D = 1.855, L = 0.6170, S = 3.005 k DESIGN SUMMARY Wood Section Name 4x4 Wood Grading/Manuf. Graded Lumber Wood Member Type Sawn Exact Width 3.50 in Allow Stress Modification Factors Exact Depth 3.50 in Cf or Cv for Bending 1.50 Area 12.25 in12 Cf or Cv for Compression 1.150 IX 12.505 inA4 Cf or Cv for Tension 1.50 ly 12.505 inA4 Cm : Wet Use Factor 1.0 Ct : Temperature Factor 1.0 Cfu : Flat Use Factor 1.0 Axial Kf : Built-up columns 1.0 15�3.2 1,600.0 ksi Use Cr: Repetitive ? No Brace condition for deflection (budding) along columns : X-X (width) axis: Unbraced Length for X-X Axis buckling = 9.0 ft, K = 1.0 Y-Y (depth) axis: Unbraced Length for X-X Axis buckling = 9.0 ft, K = 1.0 Service loads entered. Load Factors will be applied for calculations. Bending & Shear Check Results PASS Max. Axia]+Bending Stress Ratio 0.8527 :1 Maximum SERVICE Lateral Load Reactions.. Load Combination +D+S Top along Y-Y 0.0 k Bottom along Y-Y 0.0 k Governing NDS Forumla Comp Only, fc/Fc' Top along XA 0.0 k Bottom along X-X 0.0 k Location of max.above base 0.0 ft Maximum SERVICE Load Lateral Deflections ... At maximum location values are ... Along Y-Y 0.0 in at 0.0 ft abovebase Applied Axial 4.884 k for load combination : n/a Applied Mx 0.0 k-ft Applied My 0.0 k-ft Along XA 0.0 in at 0.0 ft above base Fc: Allowable 467.538 psi for load combination : n/a Other Factors used to calculate allowable stresses ... PASS Maximum Shear Stress Ratio= 0.0 :1 Bending, Compression Tension Load Combination +0.460D Location of max.above base 9.0 ft Applied Design Shear 0.0 psi Allowable Shear 288.0 psi Load Combination Results Maximum Axial + Bending Stress Ratios Maximum Shear Ratios Load Combination C D C P Stress Ratio Status Location Stress Ratio Status Location D Only 0.900 0.327 0.3360 PASS 0.0 ft 0.0 PASS 9.0 ft +D+L 1.000 0.297 0.4414 PASS 0.0 ft 0.0 PASS 9.0 ft +D+S 1.150 0.262 0.8527 PASS 0.0 ft 0.0 PASS 9.0 ft +D+0.750L+0,750S 1.150 0.262 0.8024 PASS 0.0 ft 0.0 PASS 9.0 ft +1,140D 1.600 0.192 0.3658 PASS 0,0 ft 0.0 PASS 9.0 ft +1.105D+0.750L+0.750S 1.600 0.192 0.8186 PASS 0.0 ft 0.0 PASS 9.0 ft +0.60D 1.600 0.192 0,1926 PASS 0.0 ft 0.0 PASS 9.0 ft +0.460D 1.600 0.192 0.1476 PASS 0.0 fit 0.0 PASS 9.0 ft PIN File= S:�Jobs\s18\s1811\s1811020 -917 Pine Sireefto 181203\181203 columns-enercalc trib-s1811020.ec( Nood Column ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6,17.2.2E -ic. #: KW-06006655 Licensee: SOUND STRUCTURAL SOLUTION! Description : (2-15) + (2-14) Code References Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10 Load Combinations Used : IBC 2015 General Information Analysis Method Allowable Stress Design End Fixities Top & Bottom Pinned Overall Column Height 9.0 ft ( Used for non -slender calculaticns Wood Species Douglas Fir - Larch Wood Grade No.2 Fb - Tension 900.0 psi Fv 180.0 psi Fb - Compr 900.0 psi Ft 575.0 psi Fc - Prll 1,350.0 psi Density 31.20 pcf Fc - Perp 625.0 psi E : Modulus of Elasticity ... x-x Bending y-y Bending Basic 1,500.0 1,600.0 Minimum 580.0 580.0 Applied Loads Column self weiqht included : 23.888 lbs * Dead Load Factor AXIAL LOADS ... Axial Load at 9.0 ft, D = 3.677, S = 6.127 k DESIGN SUMMARY Bending & Shear Check Results PASS Max. Axia]+Bending Stress Ratio Load Combination Governing NOS Forumla Location of maxabove base At maximum location values are . Applied Axial Applied Mx Applied My Fc: Allowable PASS Maximum Shear Stress Ratio Load Combination Location of max.above base Applied Design Shear Allowable Shear Load Combination Results A" ow NEW W Wood Section Name 4x4 Wood Grading/Manuf. Graded Lumber aw Wood Member Type Sawn P" Exact Width 3.50 in Allow Stress Modification Factors Exact Depth 3.50 in Cf or Cv for Bending 1.50 Area 12.25 in12 Cf or Cv for Compression 1.150 Ix 12.505 in14 Cf or Cv for Tension 1.50 Pq ly 12.505 in14 Cm : Wet Use Factor 1.0 Ct : Temperature Factor 1.0 so Cfu : Flat Use Factor 1.0 Axial Kf : Built-up columns 1.0 NDS 15.12 1,600.0 ksi Use Cr: Repetitive ? No Brace condition for deflection (buckling) along columns : X-X (width) axis: Fully braced against buckling along X-X Axis Y-Y (depth) axis: Fully braced against buckling along Y-Y Axis Service loads entered. Load Factors will be al)Dlied for calculations. 0.4494:1 +D+S Comp Only, fc/Fc' 0.0 It 9.828 k 0.0 k-ft 0.0 k-ft 1,785.38 psi 0.0 :1 +0.460D 9.0 ft 0.0 psi 288.0 psi Maximum SERVICE Lateral Load Reactions.. Top along Y-Y 0.0 k Bottom along Y-Y 0.0 k Top along X-X 0.0 k Bottom along X-X 0.0 k Maximum SERVICE Load Lateral Deflections ... Along Y-Y 0.0 in at 0.0 ft above base for load combination : n/a Along X-X 0.0 in at 0.0 ft ab6ve base for load combination : n/a Other Factors used to calculate allowable stresses ... Bendin_q Compression Tension Load Combination C D C P Maximum Axial + Bending Stress Ratio Status Stress Ratios Location Maximum Shear Ratios Stress Ratio Status Location D Only 0.900 1.000 0.2162 PASS 0.0ft 0.0 PASS 9.0 ft +D+S 1.150 1.000 0.4494 PASS 0.0 ft 0.0 PASS 9.0 ft +D+0.750S 1.150 1.000 0.3793 PASS 0.0 ft 0.0 PASS 9.0 ft +1.140D 1.600 1.000 0.1387 PASS 0.0 ft 0.0 PASS 9.0 ft +1.105D+0.750S 1.600 1.000 0.2854 PASS 0.0 ft 0.0 PASS 9.0 ft +0.60D 1.600 1.000 0.07297 PASS 0.0 ft 0.0 PASS 9.0 ft +0,460D 1.600 1.000 0.05595 PASS 0.0 ft 0.0 PASS 9.0 ft pim bow bow - Q�li r rl GRAVITY ANALYSIS Truss Layout 6628 212th Street SW, Suite 205 - Lynnwood, WA 98036 - Ph: 425-778-1023 - Fax: 206-260-7490 File= S1Jobs\s18%s18I11s1811020 - 917 Pine Sbeetkwo 181203QF-enercalc t6b 1801311-ed General Beam Analysis ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.17.2.2E Lic. #: KW-06006655 Licensee: SOUND STRUCTURAL SOLUTIONS Description : (2-6) General Beam Properties Elastic Modulus 29,000.0 ksi Span #1 Span Length 18.0 ft Area = 10.0 in'12 Moment of Inertia = 100.0 in A 4 UAW Q(0.04) U0. 121 S(O.051 Span = 18.0 R Applied Loads Service loads entered. Load Factors will be applied for calculations. Uniform Load : D = 0.020, L = 0.060, S = 0.0250 ksf, Tributary Width = 2.0 ft, (ROOF DECK) DESIGN SUMMARY Maximum Bending 6.954 k-ft Maximum Shear 1.545 k Load Combination +1.105D+0.750L+0.750S Load Combination +1.105D+0.750L+0.750S Location of maximum on span 9.000ft Location of maximum on span 0.000 ft Span #where maximum occurs Span # 1 Span # where maximum occurs Span # 1 Maximum Deflection Max Downward Transient Deflection 0.099 in 2192 Max Upward Transient Deflection 0.000 in 0 Max Downward Total Deflection 0.138 in 1570 Max Upward Total Deflection 0.000 in 0 Forces & Stresses for Load Combinations -Maximum Load Combination Max Stress Ratios Summary of Moment Values Summary of Shear Values Segment Length Span # M V Mmax + Mmax - Ma - Max Mnx MnxtOmega Clb Rm Va Max Vnx Vnx/Omega Overall MAXimum Envelope Dsgn. L = 18.00 It 1 6.95 6.95 1.55 D Only Dsgn. L = 18.00 It 1 1.62 1,62 0.36 +D+L Dsgn. L = 18.00 It 1 6.48 6.48 1.44 +D+S Dsgn. L = 18.00 ft 1 3.65 3.65 0.81 +D+0.750L+0.750S Dsgn. L = 18.00 It 1 6.78 6.78 1.51 +1.140D Dsgn. L = 18.00 ft 1 1.85 1.85 0.41 +1.1 05D+0.750L+0.750S Dsgn. L = 18.00 ft 1 6.95 6.95 1.55 +0.60D Dsgn. L = 18.00 ft 1 0.97 0.97 0.22 +0.460D Dsgn. L = 18.00 It 1 0.75 0.75 0.17 --Overall Maximum Deflections Load Combination Span Max. Defl Location in Span Load Combination Max. "+" Defi Location in Span +D+0.750L+0.750S 1 0.1375 9.090 0.0000 0.000 Vertical Reactions Support notation Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Overall MAXimum 1.508 1.508 Overall MINimum 0,216 0,216 D Only 0,360 0.360 +D+L 1440 1.440 +D+S 9.810 0.810 +D+0.750L+0.750S 1,508 1.508 +0.60D 0.216 0.216 L Only 1,080 1.080 S Only 0.450 0.450 I F0 MW 13'eneral Beam Analysis File= SAJobs\s18\s1811\s1811020 - 917 Pine Street\wo 181201181203_2Fenercalc trib_s1811M�( ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ven6.1722 Lic. #: KW-06006655 Licensee � SOUND STRUCTURAL SOLUTOM Description (2-8) A General Beam Properties Elastic Modulus 29,000.0 ksi Span #1 Span Length = 18.0 ft Area = 10.0 in A 2 Moment of Inertia = 100.0 inA4 Span #2 Span Length = 4.0 ft Area = 10.0 in A 2 Moment of Inertia = 100.0 inA4 1)(0.03) L(O.�) S(O.0375) Q(0 SM. �j 5) L(01) 9W7 tj) L(O�42) S(O-175) V Span= 18.0 ft Span = 4.0 ft Applied Loads Service loads entered. Load Factors will be applied for calcullations. Load for Span Number I Uniform Load: D = 0.020, L = 0,060, S = 0.0250 ksf, Tributary Width = 1.50 ft, (ROOF DECK) Load for Span Number 2 Uniform Load: D = 0.020, L = 0.060, S = 0.0250 ksf, Tributary Width = 7.50 ft, (ROOF DECK) PointLoad: D=0.140, L=0.420, S=0.1750k@4.Oft,((2-7)) DESIGN SUMMARY Maximum Bending 7.555 k-ft Maximum Shear = 3.176 k Load Combinafion +1.105D+0.750L+0.750S Load Combination +1.105D+0.750L+0.750& I Location of maximum on span 18.000ft Location of maximum on span 18.000 ft Span # where maximum occurs Span # 1 Span # where maximum occurs Span # 1 Maximum Deflection Max Downward Transient Deflection 0.037 in 2578 Max Upward Transient Deflection -0.006 in 35111 Max Downward Total Deflection 0.052 in 1846 Max Upward Total Deflection -0-009 in 25154 Maximum Forces & Stresses for Load Combinations Load Combination Max Stress Ratios Summary of Moment Values Summary of Shear Values Segment Length Span # M V Mmax + Mmax - Ma - Max Mnx Mnx/Omega Cb Rm Va Max Vnx VrTx/Omega Overall MAXimum Envelope Dsgn. L = 18.00 ft 1 2.12 -7.55 7.55 3.18 Dsgn. L = 4.00 ft 2 -7.55 7.55 3.18 D Only Dsgn. L = 18.00 ft 1 0.49 -1.76 1.76 0.74 l� I)sgn. L = 4.00 ft 2 -1.76 1,76 0.74 ftd +D+L Dsgn. L = 18.00 ft 1 1.98 -7,04 7.04 2.96 Dsgn. L = 4.00 It 2 -7.04 7.04 2.96 +D4S Dsgn. L = 18.00 ft 1 1.11 -3.96 3.96 1.67 Dsqn. L = 4.00 ft 2 -3.96 3.96 1.67 +D+0.750L+0.750S Dsgn.L= 18.00ft 1 2.07 -7.37 7.37 3.10 Dsgn. L = 4.00 It 2 -7.37 7.37 3.10 +1.140D NOW Dsgn. L = 18.00 ft 1 0.56 -2.01 2.01 0.84 Dsgn. L = 4.00 ft 2 -2.01 2.01 0.84 +1.105D+0.750L+0.750S Dsgn. L = 18.00 ft 1 2.12 -7.55 7.55 3.18 Dsgn. L = 4.00 ft 2 -7.55 7.55 3.18 +0.6DD Dsgn. L = 18.00 ft 1 0.30 -1.06 1.06 0.44 Dsgn. L = 4.00 it 2 -1.06 1.06 0,44 +0.460D Dsgn. L = 18.00 ft 1 0.23 -0.81 0.81 0.34 Dsgn. L = 4.00 ft 2 -0.81 0.81 0.34 General Beam Analysis File= S*.UobMs18W811\s1811020 - 917 Pine Streefto 18120M181203-2F_enercalc trib_s1811020.ec( ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.17.2.2f Lic. # : KW-06006655 Licensee: SOUND STRUCTURAL SOLUTIONS Description : (2-8) A Overall Maximum Deflections Load Combinaton Span Max. "-" DO Location in Span Load Combination Max.Y' Defl Location in Span +D+0.750L+0.750S 0.0190 6.092 +D+0.750L+0.750S -0.0086 15.646 +D+0.750L+0.750S 2 0.0520 4.000 0.0000 15.646 Vertical Reactions Support notation Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Support 3 Overall MAXimurn 0.721 4.639 Overall MlNimum 0.103 0.665 D Only 0.`172 1.108 +D+L 0.689 4.431 +D+S 0.388 2.493 +D+0.750L+0.750S 0.721 4.639 +0.60D 0.103 0.665 L Only 0.517 3.323 S Only 0.215 1.385 Pq 6.0 I PM P0 General Beam Analysis 111117N.7111,471,1MM.11, Description : (2-8) B General Beam Properties Elastic Modulus 29,000.0 ksi Span #1 Span Length = Span #2 Span Length = File= SAJobs\s18\s1811\s1811020 - 917 Pine Streefwo 181203\181203 2F enercalc trib-sl8l 1020.ed ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.17.2.' 2E 18.0 ft Area = 10.0 in A 2 Moment of Inertia = 100.0 in A 4 4.0 ft Area = 10.0 in1\2 Moment of Inertia = 100.0 in A 4 MO.= L(Of S(O.0375) D(�Q D(O.14) L(O.42) S(O.175) Span = 18.0 ft Span = 4.0 ft -Applied Loads Service loads entered. Load Factors will be applied for calculations. Load for Span Number I Uniform Load: D = 0.020, L = 0.060, S = 0.0250 ksf, Tributary Width = 1,50 ft, (ROOF DECK) Load for Span Number 2 Uniform Load : D = 0.020 ksf, Tributary Width = 7.50 Ift, (ROOF DECK) Point Load : D = 0.140, L = 0.420, S = 0.1750 k @ 4.0 ft, ((2-7)) DESIGN SUMMARY Maximum Bending 3.730 k-ft Maximum Shear 1.366 k Load Combination +1.105D+0.750L+0.750S Load Combination +1.105D+0.750L+0.750S Location of maximum on span 18,000ft Location of maximum on span 18.000 ft Span # where maximum occurs Span # 1 Span # where maximum occurs Span # I Maximum Deflection Max Downward Transient Deflection 0.054 in 4007 Max Upward Transient Deflection -0.023 in 4210 Max Downward Total Deflection 0.061 in 3541 Max Upward Total Deflection -0.012 in 8128 -Maximum Forces & Stresses for Load Combinations Load Combination Max Stress Ratios Summary of Moment Values Summary of Shear Valu-e-s Segment Length Span # M V Mmax + Mmax - Ma - Max Mnx Mnx/Ornega Ob Rm Va Max Vnx Vnx/Omega Overall MAXimum Envelope Dsgn. L = 18.00 ft 1 3.52 -3.73 3.73 1.37 Dsgn. L = 4.00 ft 2 -3.73 3.73 1.26 D Only Dsgn. L = 18.00 ft 1 0.49 -1.76 1.76 0.74 Dsgn. L = 4.00 It 2 -1.76 1.76 0.74 +D+L Dsqn. L = 18.00 ft 1 3.29 -3.44 3.44 1.27 Dsgn. L = 4.00 ft 2 -3.44 3.44 1.16 +[)+S Dsgn. L = 18.00 ft 1 1.64 -2.46 2.46 0.92 Dsgn. L = 4.00 ft 2 -2.46 2.46 0.92 +[)+0.750L+0.750S Dsgn. L = 18.00 ft 1 3.47 -3.55 3.55 1.33 Dsgn. L = 4.00 ft 2 -3.55 3.55 1.19 +1.140D Dsgn. L = 18.00 ft 1 0.56 -2.01 2.01 0.84 Dsgn. L = 4.00 ft 2 -2.01 2.01 0.84 +1.105D+0.750L+0.750S Dsgn. L = 18.00 ft 1 3.52 -3.73 3.73 1.37 Dsgn. L = 4.00 It 2 -3.73 3.73 1.26 +0.60D Dsgn. L = 18.00 ft 1 0.30 -1.06 1.06 0.44 Dsgn. L = 4.00 ft 2 -1.06 1.06 0.44 +0.460D Dsgn. L = 18.00 ft 1 0.23 -0.81 0.81 0.34 Dsgn. L:= 4.00 ft 2 -0.81 0.81 0.34 on N.W General Be I am Analysis File= S:\Jobs\s18\s1811\s1811020 - 917 Pine Street\wo 181203\1812032F — enercalctrib—s1811020,ecl k ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.17.2.2f I Lic. #: KW-06006655 Licensee: SOUND STRUCTURAL SOLUTIONS Description : (2-8) B Overall Maximum Deflections Load Combination Span Max. %" Defl Location in Span - Load Combination Max."+" Dell Location in Span +D+0.750L+0.750S 1 0. 8.308 0.0000 0.000 2 0.0000 8.308 L Only -0.0228 4.000 Vertical Reactions Support notation : Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Support 3 Overall MAXimum 0.934 2.514 Overall MINimum 0.103 0.551 D Only 0.172 1.108 +D+L 0.889 2.431 +D+S 0.47'1 1.659 +D+0.750L+0.750S 0.9a4 2.514 +0,60D 0.103 0.665 L Only 0.717 1.323 S Only 0.299 0.551 General Beam Analysis Description : (2-8) C General Beam Properties Elastic Modulus 29,000.0 ksi Span #1 Span Length = Span #2 Span Length = W one File= SAJobs\s18\s18Ms1811020 - 917 Pine Streetwo 181203\181203L2Fenercalc tdb_51811020.ed ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver-6.1722E 18.0 ft Area = 10.0 in A 2 Moment of Inertia = 100.0 in A 4 4.0 fit Area = 10.0 in A 2 Moment of Inertia = 100.0 in A 4 D(V3) D(V5) L(O.!*L5) S(09 L(O.42) S(O.175) Span = 18.0 ft Span = 4.0 ft Pq -Applied Loads Service loads entered. Load Factors will be applied for calculations. Load for Span Number I kmd Uniform Load: D = 0.020 ksf, Tributary Width = 1.50 ft, (ROOF DECK) Load for Span Number 2 Uniform Load : D = 0.020, L = 0.060, S = 0.0250 ksf, Tributary Width = 7�50 ft, (ROOF DECK) 7 Point Load : D = 0.140, L = 0.420, S = 0.1750 k @ 4.0 ft, ((2-7)) DESIGN SUMMARY Now P" bow Maximum Bending = 7.555 k-ft Maximum Shear = 3.176 k Load Combination +1.105D+0.750L+0.750S Load Combination +1.105D+0.750L+0.750S Location of maximum on span 18.000ft Location of maximum on span 18.000 ft Span # where maximum occurs Span # 1 Span # where maximum occurs Span # 1 Maximum Deflection Max Downward Transient Deflection 0.089 in 1074 Max Upward Transient Deflection -0.066 in 3270 Max Downward Total Deflection 0.107 in 894 Max Upward Total Deflection -0.068 in 3157 Maximum Forces & Stresses for Load Combinations Load Combination Max Stress Ratios Summary of Moment Values Summary of Shear Values - Segment Length Span # M V Mmax + Mmax - Ma - Max Mnx Mnx/Omega Cb Rm Va Max Vnx Vnx/Omega Overall MAXimum Envelope Dsgn. L = 18.00 It 1 0.28 -7.55 7.55 3.18 Dsgn. L = 4.00 ft 2 -7.55 7.55 3.18 D Only Dsgn. L = 18.00 ft 1 0.49 -1.76 1.76 0.74 Dsgn. L = 4.00 ft 2 -1.76 1.76 0.74 +D+L Dsgn. L = 18.00 ft 1 -7.04 7.04 2.96 Dsgn. L = 4.00 ft 2 -7.04 7.04 2.96 +Di-S Dsgn. L = 18.00 ft 1 0.04 -3.96 3.96 1.67 Dsgn. L = 4.00 ft 2 -3.96 3.96 1.67 +D+0.750L+0.750S Dsgn. L = 18.00 ft 1 -7.37 7.37 3.10 Csgn. L = 4.00 ft 2 -7.37 7.37 3.10 +1.140D I)sgn. L = 18.00 ft 1 0.56 -2.01 2.01 0.84 Dsgn. L = 4.00 ft 2 -2.01 2.01 0.84 +1.,105D+0.750L+0.750S Csgn. L = 18.00 ft 1 -7.55 7.55 3.18 Dsgn. L = 4.00 It 2 -7.55 7.55 3.18 +0.60D Osgn. L = 18.00 ft 1 0.30 -1.06 1.06 0.44 Dsgn. L = 4.00 ft 2 -1.06 1.06 0.44 +0.460D Dsgn. L = 18.00 ft 1 0.23 -0.81 0.81 0.34 Osgn. L = 4.00 It 2 -0.81 0.81 0.34 File= S.UobsAsi8As181%1811020 - 917 Pine Streeftwo 1812031181203 - 2F - enercalc tdb-sl 811020.eC, I �eam Analysis ENERCALC, INC. 1983-2017, Build:6.17.2,28, Ver:6.17.2.2f Lic. #: KW-06006655 Licensee: SOUND STRUCTURAL SOLUTIONS Description : (2-8) C Overall Maximum Deflections Load Combination Span Max . ..... Defl Location in Span Load Combination Max. "+" Defl Location in Span 1 0.0000 0.000 +D+0.750L+0Y50S -0.0684 10.938 +D+0.750L+0.750S 2 0.1073 4.000 0.0000 10.938 Vertical Reactions Support notation Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Support 3 Overall MAXimum -0.293 3.778 Overall MINimum 0.050 0.665 D Only 0.172 1.108 +D+L -0.121 3.621 +D+S 0.050 2.155 +D+0.750L+0.750S -0.139 3.778 +0.60D 0.103 0.665 L Only -0.293 2.513 S Only -0.122 1.047 NEW 41111111 [General Beam Analysis File= S.Uobs1s18%s18111s1811020-917 Pine Streefto 1812030 enercalctrib 180131.ec( ENERCALC, INC. 1983-2017, Build:6.17.2,28, Ver:6.17.22E 06 In 0" Description (2-9) General Beam Properties Elastic Modulus 29,000.0 ksi Span #1 Span Length 18.0 ft Area 10.0 inA2 Moment of Inertia 100.0 in A 4 'i Q(0,06) UVII) S(C.075) T--- Applied Loads Service loads entered. Load Factors will be applied for calculations. Uniform Load: D = 0.020, L = 0.060, S = 0.0250 ksf, Tributary Width = 3.0 ft, (ROOF DECK) DESIGN SUMMARY Maximum Bending 10.431 k-ft Maximum Shear 2.318 k Load Combination +1.105D+0.750L+0.750S Load Combination +1.105D+0.750L+0.750S Location of maximum on span 9.000ft Location of maximum on span 0.000 ft Span # where maximum occurs Span # I Span # where maximum occurs Span # I Maximum Deflection Max Downward Transient Deflection 0.148 in 1461 Max Upward Transient Deflection 0.000 in 0 Max Downward Total Deflection 0.206 in 1047 1 L Max Upward Total Deflection 0.000 in 0 Maximum Forces & Stresses for Load Combinations Load Combination Max Stress Ratios Summary of Moment Values Summary of Shear Values- - Segment Length Span # M V Mmax + Mmax - Ma - Max Mnx MnxtOmega Cb Rm Va Max Vnx Vnx/Omega Overall MAXimum Envelope Dsgn. L = 18.00 It 1 10.43 10.43 2.32 D Only Dsgn. L = 18.00 It 1 2.43 2.43 0.54 +[)+L Dsgn. L = 18.00 It 1 9.72 9.72 2.16 +D+S Dsgn. L = 18.00 It 1 5.47 5.47 1.22 +D+0.750L+0.750S Dsgn. L = 18.00 It 1 10.18 10.18 2.26 +1.140D Dsgn. L = 18.00 It 1 2.77 2.77 0.62 + 1. 1 05D+0.750L+0.750S Dsgn. L = 18.00 ft 1 10.43 10,43 2.32 +0.60D Dsgn, L = 18.00 ft 1 1.46 1.46 0.32 +0.460D taw Dsgn. L = 18.00 It 1 1.12 1.12 0.25 Overall Maximum Deflections Load Combination Span Max. Defi Location in Span Load Combination Max."+" Defi Location in Span +D+0.750L+0.750S 1 0.2063 9.090 0.0000 0.000 Vertical Reactions Support notation Far left is #1 Values in KIPS Load Combination Support I Support 2 Overall MAXimum 2.261 2.261 Overall MINimurn 0.324 0.324 0 Only 0.540 0.540 +D+L 2.160 2.160 +D+S 1.215 1.215 +D+0.750L+0.750S 2.261 2.261 +0.60D 0.324 0.324 L Only 1.620 1.620 S Only 0.675 0.675 low km File= SAJo1bs\s18\s1811\s1811020 - 917 Pine Streefto 181203\181203 2F-enercalctdb-s1811020,ed 3eneral Beam Analysis ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.17.2.2E . Jc. # : KW-06006655 Licensee: SOUND STRUCTURAL SOLUTIOW-, Description : (2-10) General Beam Properties Elastic Modulus 29,000.0 ksi Span #1 Span Length = 11.750 ft Area = 10.0 in A 2 Moment of Inertia = 100.0 in A 4 Span #2 Span Length = 11.750 ft Area = 10.0 in A 2 Moment of Inertia = 100.0 in A 4 MO 015; S(O.025) T Q(0.04) L(CL12) S(O.05) D(O.OV(0.05) Span = 11.750 ft Span = 11.750 ft Applied Loads Service loads entered. Load Factors will be applied for calculations. Load for Span Number 1 Uniform Load: D = 0.020, L = 11060, S = 0.0250 ksf, Tributary Width = 2.0 ft, (ROOF DECK) Uniform Load: D = 0.0150, S =0.0250 k/ft, Tributary Width = 1.0 ft, (ROOF) Load for Span Number 2 Uniform Load: D = 0.0150, S = 0.0250 ksf, Tributary Width = 2.0 ft, (ROOF) DESIGN SUMMARY Maximum Bending 2.475 k-ft Maximum Shear = 1.420 k Load Combination +1,105D+0.750L+0.750S Load Combination +1.105D+0.750L+0.750S Location of maximum on span 4.881 ft Location of maximum on span 11.750 ft Span # where maximum occurs Span # 1 Span # where maximum occurs Span # 1 Maximum Deflection Max Downward Transient Deflection 0.013 in 11158 Max Upward Transient Deflection -0.006 in 25295 Max Downward Total Deflection 0.018 in 7726 Max Upward Total Deflection -0.005 in 26740 Maximum Forces & Stresses for Load Combinations Load Combination Wx Stress Ratios Summary of Moment Values Summary of Shear Values Segment Length Span # M V Mmax + Mmax - Ma - Max Mnx Mnx/Omega Clo Rm Va Max Vnx Vnx/Omega Overall MAX!mum Envelope Dsgn. L = 11.75 It 1 2.48 -2.40 2.48 1.42 Dsgn. L = 11.75 ft 2 0.62 -2.40 2,40 0.62 D Only Dsgn. L = 11.75 ft 1 0.62 -0.73 0.73 0.39 Dsgn. L = 11.75 ft 2 0.22 -0.73 0.73 0.24 +D+L Dsgn. L = 11,75 ft 1 2.20 -1.77 2.20 1.18 Dsgn. L = 11,75 ft 2 Hi -1.77 1.77 0.33 +D+S Dsgn. L = 11.75 ft 1 1.43 -1.81 1.81 0.92 Dsgn. L = 11.75 ft 2 0.62 -1.81 1.81 0.62 +D+0.750L+0.750S Dsgn.L= 11.75ft 1 2.41 -2.32 2.41 1.38 Dsgn.L= 11.75ft 2 0.29 -2.32 2.32 0.59 +1.140D Dsgn. L = 11.75 ft 1 0.70 -0.84 0.84 0.44 Dsgn. L = 11.75 ft 2 0.25 -0.84 0.84 0.27 +1.105D+0.750L+0.750S Dsgn. L = 11.75 ft 1 2.48 -2.40 2.48 1.42 Dsgn. L = 11.75 ft 2 0.32 -2.40 2.40 0.62 +0.60D Dsgn. L = 11.75 ft 1 0.37 -0.44 0.44 0.23 Dsgn. L = 11.75 ft 2 0.13 -0.44 0.44 0.14 +0.460D Dsgn. L = 11.75 ft 1 0.28 -0.34 0.34 0,18 Dsgn. L = 11.75 ft 2 0.10 -0.34 0,34 0.11 w WWI ro iw General Beam Analysis e.i ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.17.2.21! File= SAJob0slffisl8l %1811020 917 Vine Streelkwo 181203k1812D3L2F_enerCaIc td�-0811020.,�� Lic. #:,KW-06006655 Licensee 1 Z411" 9 46161 1 Description : (2-10) Overall Maximum Deflections Load Combination Span Max . ..... Dell Location in Span Load Combination Max. 'Y' Defl Location in Span +D+0.750L+0.750S 1 0.0182 5,423 0.0000 0.000 2 0.0000 5.423 L Only -0.0056 4.971 Vertical Reactions Support notation: Farleftis#1 Values in KIPS Load Combination Support 1 Support 2 Support 3 Overall MAXimum 0.985 1.974 0.316 Overall MINimum 0.156 0.375 0.026 D Only 0.261 0.624 0.114 +D+L 0.878 1.505 0.026 +D+S 0.610 1.542 0.316 +D+0.750L+0,750S 0.985 1.974 0.199 +0.60D 0.156 0.375 0.068 L Only 0.617 0.881 -0.088 S Only 0.349 0.918 0.202 General Beam Analysis Description (2-11) A General Beam Properties Elastic Modulus 29,000.0 ksi Span #11 Span Length = Span #2 Span Length = Span #3 Span Length = 11M VM lew File= SAJobs\s1&s181l\sl811020 - 917 Pine Street\wo 181203\1812032Fenercalc tdb-s1811020.ed ENERCALC, INC. 1983-2017, Build:6.17.2.28, r76.17.2.2f W - Licensee: SOUND STRUCTURAL SOLUTIONS' AM 6.0 ft Area = 10.0 in12 Moment of Inertia = 100.0 in A 4 4W 16.333 ft Area = 10.0 in A 2 Moment of Inertia = 100.0 in A 4 2.750 ft Area = 10.0 in A 2 Moment of Inertia = 100.0 in A 4 D(O.18) L(Q )S(0.225) �OQ Lft O(O.285),S(O.356) D(0-14)S(O.1751 D(O.36) L(I.08) S(O.45) Q(0,12) S(O.15) D(O.204) Q0.61) S(O.255) D(O.54) L(1.62) bp qff$n� (0,882) S(O.91 8) Span 6.0 ft Span = 16.333 ft Span = 2.750 ft Applied Loads Service loads entered. Load Factors will be applied for calculations. Load for Span Number 1 Uniform Load : D = 0.020, S = 0.0250 ksf, Tributary Width = 7.0 ft, (ROOF) Point Load: D = 0.2850, S = 0.3560 k (cb, 0.0 ft, ((2-3)) Load for Span Number 2 Uniform Load : D = 0.020, S = 0.0250 ksf, Tributary Width = 6.0 ft, (ROOF) Point Load D = 0,360, L = 1.080, S = 0.450 k @_ 3.250 ft, ((2-6)) Point Load D = 0,2040, L = 0.610, S = 0.2550 k @ 12.50 ft, ((2-8)) Uniform Load: D = 0.020, L = 0.060, S = 0.0250 ksf, Tributary Width = 9.0 ft, (ROOF DECK) Load for Span Number 3 Uniform Load: D = 0,020, S = 0.0250 ksf, Tributary Width = 6.0 fl, (ROOF) Point Load: D = 0,540, L = 1.620, S = 0.6750 k 0_ 0.0 ft, ((2-9)) Uniform Load : D = 0.020, L = 0.060, S = 0.0250 k/ft, Tributary Width = 1.0 ft, (ROOF DECK) Point Load: D = H250, L = 03820, S = 0.9180 k @ 2.750 ft, ((2-10)) DESIGN SUMMARY Maximum Bending 30.370 k-ft Maximum Shear = 9.863 k Load Combination +1.105D+0.750L+0.750S Load Combination +1.105D+0.750L+0.750S Location of maximum on span 8.270ft Location of maximum on span 6.000 ft Span # where maximum occurs Span # 2 Span # where maximum occurs Span # 1 Maximum Deflection Max Downward Transient Deflection 0.333 in 587 Max Upward Transient Deflection -0.395 in 364 Max Downward Total Deflection 0.483 in 406 Max Upward Total Deflection -0.229 in 288 Maximum Forces & Stresses for ILoad Combinations Load Combination Max Stress Ratios Summary of Moment Values Summary of Shear Values Segment Length Span # M V Mmax + Mmax - Ma - Max Mnx Mnx/Omega Cb Rm Va Max Vnx Vnx/Omega Overall MAXimum Envelope Dsgn. L = 6.00 ft 1 -9.52 9.52 9.86 Dsgn. L = 16.33 ft 2 30.37 -9.52 30.37 9.86 Dsgn. L = 2.75 ft 3 -6.86 6.86 2.95 D Only Dsgn. L = 6.00 ft 1 -4.23 4.23 2.91 Dsgn. L = 16.33 ft 2 7.76 -4.23 7.76 2.91 Dsgn. L = 2.75 ft 3 -2.25 2.25 1.01 +D+L Dsgn. L = 6,00 ft 1 -4.23 4.23 8.16 Dsgn. L = 16.33 ft 2 27.36 4.90 27.36 8.16 Dsgn. L = 2,75 ft 3 -4.90 4.90 2.06 +D+S Dsgn. L = 6.00 ft 1 -9.52 9.52 6.52 Dsgn. L = 16.33 ft 2 17.26 -9.52 17.26 6.52 Dsgn. L = 2.75 ft 3 -5.43 5.43 2.41 +D+0.750L+0.750S Dsgn. L = 6.00 ft 1 -8.19 8.19 9.56 Dsgn. L = 16.33 ft 2 29.56 -8.19 29.56 9.56 PSI OW old M0 Eft am ow OR i , I � i 00 00 r. r F0 moo fo jow Beam Analysis File - SAJoWsMs181%1811020 - 917 Pine Streetwo 181203\181203L2F_enerealc tdlx_slaI I 020.eil [General -KW-06006655 ENERCALC, INC. 1983-2017, Build:6.17-2.28, Ver,15.17.2.2f IlLic.-W-.. Licensee.- SOUND STRUCTURAL SOWT14 Description : (2-11) A Load Combination Max Stress Ratios Summary of Moment Values Summary of Shear Values Segment Length Span # M V Mmax + Mmax - Ma - Max Mnx MnxtOmega Cb Rm Va Max Vnx Vnx/Ornega Dsgn.L= 2.75ft 3 -6.63 6.63 2.84 +1.140D Dsgn. L = 6.00 ft 1 -4.82 4.82 3.31 Dsgn. L = 16.33 ft 2 8.84 4.82 8.84 3.31 Dsgn.L= 2.75ft 3 -2.56 2.56 1.15 +1.105D+0.750L+0.750S Dsgn. L = 6.00 ft 1 -8.64 8.64 9.86 Dsgn. L = 16.33 ft 2 30.37 -8.64 30.37 9.86 Dsgn. L = 2.75 ft 3 -6.86 6.86 2.95 +0.60D Dsgn. L = 6.00 ft 1 -2.54 2,54 1.74 Cisgn. L = 16.33 ft 2 4.65 -2.54 4,65 1.74 Dsgn. L = 2.75 ft 3 -1.35 1.35 0.61 +0,460D Dsgn. L = 6.00 ft 1 -1.95 1.95 1.34 Dsgn. L = 16.33 ft 2 3.57 -1.95 157 1.34 Dsgn. L = 2.75 ft 3 -1.03 1.03 0.46 Overall MaximurnDeflections Load Combination Span Max. Defl Location in Span Load Combination Max. "+" Defi Location in Span 1 0.0000 H00 +D+L -OA836 0.000 +D+0.750L+0.750S 2 0.4825 8.270 0.0000 1000 3 0.0000 8.270 +D+0.750L+0.750S -0.2290 Z750 Vertical Reactions Support notation : Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Support 3 Support 4 Overall MAXimum 11.737 14.017 Overall MINimum 2.420 2.464 D Only 4.033 4.106 +D+L 9.288 12.028 +D+S 9.050 9.399 +D+0.750L+0.750S 11.737 14.017 +0.60D 2.420 2.464 L Only 5.256 7,921 S Only 5.017 5.293 File= SAJobs\s18\s18Ms1811020- 917 Pine StreeAwo 181203QF enercalctrib180131 -'ec, General Beam Analysis ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.17.2.2E Lic. # : KW-06006655 Licen-see : SOUND STRUCTURAL SOLUTIONS Description : (2-11) B General Beam Properties Elastic Modulus 29,000.0 ksi Span #1 Span Length 6.0 ft Area = 10.0 in A 2 Moment of Inertia = 100.0 in A 4 Span #2 Span Length = 16.333 ft Area = 10.0 in A 2 Moment of Inertia = 100.0 in A 4 Span #3 Span Length = 2.750 ft Area = 10.0 in A 2 Moment of Inertia = 100.0 in A 4 D(O.18) L( M0.225) III + * * _�121 D(o.?85) N0.14) D(O.36) Q11.08) 45) Q(Q. 12) SM. 15) D(O.204) L4,61) S(O.255) D(O,.54) Q(0.12) D(O.V25) Span = &0 ft Span = 16,333 ft Span = 2.750 ft Applied Loads Service loads entered. Load Factors will be applied for calculations. Load for Span Number 1 Uniform Load : D = 0.020 ksf, Tributary Width = 7.0 ft, (ROOF) PointLoad: D=0.2850k0,0.Gft,((2-3)) Load for Span Number 2 Uniform Load: D = 0.020, S = 0,0250 ksf, Tributary Width = 6.0 ft, (ROOF) Point Load: D = 0.360, L = 1.0-130, S = 0.450 k @ 3.250 ft, ((2-6)) Point Load: D = 0.2040, L = 0.610, S = 0.2550 k @ 12.50 ft, ((2-8)) Uniform Load: D = 0.020, L = 0.060, S = 0.0250 ksf, Tributary Width = 9.0 ft, (ROOF DECK) Load for Span Number 3 Uniform Load : D = 0.020 ksf, Tributary Width = 6.0 ft, (ROOF) Point Load : D = 0.540 k @ 0.0 ft, ((2-9)) Uniform Load: D = 0.020 k/ft, Tributary Width = 1.0 ft, (ROOF DECK) Point Load : D = 0.6250 k @ 2.750 ft, ((2-10)) DESIGN SUMMARY Maximum Bending 34.544 k-ft Maximum Shear = 9.889 k Load Combination +1.105D+0.750L+0.750S Load Combination +1.105D+0.750L+0.750S Location of maximum on span 8.270 ft Location of maximum on span 6.000 ft Span # where maximum occurs Span # 2 Span # where maximum occurs Span # 1 Maximum Deflection Max Downward Transient Deflection 0.360 in 544 Max Upward Transient Deflection -0.421 in 340 Max Downward Total Deflection 0.567 in 345 Max Upward Total Deflection -0.292 in 226 Maximum Forces & Stresses for ILoad Combinations Load Combination Max Stress Ratios Summary of Moment Values Summary of Shear Values Segment Length Span # V1 V Mmax + Mmax - Ma - Max Mnx Mnx/Omega Cb Rm Va Max Vnx Vnx/Omega Uverall MAXimum Lnvelope Dsgn. L = HO ft 1 4.82 4.82 9.89 Dsgn. L = 16.33 ft 2 34.54 -4.82 34.54 9.89 Dsgn. L = 2,75 ft 3 -2.56 2.56 1.15 D Only Dsgn. L = 6.00 ft 1 4.23 4.23 2.91 Dsgn. L = 16.33 ft 2 7.76 -4.23 7.76 2.91 Dsgn. L = 2.75 ft 3 -2.25 2.25 1.01 +D+L Dsgn. L = 6.00 ft 1 4.23 4.23 8.33 Dsgn. L = 16.33 ft 2 28.67 4.23 28.67 8.33 Dsgn. L = 2.75 ft 3 -2.25 2.25 1.01 +D+S Dsgn. L = 6.00 ft 1 -4.23 4.23 6.39 Dsgn. L = 16.33 ft 2 21.47 4.23 21.47 6.39 Dsgn. L = 2.75 ft 3 -2.25 2.25 1.01 +D+0.750L+0.750S Dsgn. L = 6.00 ft 1 4.23 4.23 9.58 Dsgn. L = 16.33 ft 2 33.73 4.23 33.73 9.58 40 4VO lilw, $0 so *ad General Beam Analysis File =SAJobs\s18\s1811\s1811020-917 Pine Streefto 181203\2F - enerGalc trib 180131-ed ENEIRCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.17.2 2E low Desciription: (2-11) B me Load Combination Max Stress Ratios Summary of Moment Values Summary of Shear Values Segment Length Span # M V Mmax + Mmax - Ma - Max Mnx MnxtOmega Cb Rm Va Max Vnx Vnx/Ornega Dsgn. L = 2.75 ft 3 -2.25 2.25 1.01 +1.140D Dsgn. L = 6.00 ft 1 -4.82 4.82 331 Dsgn. L = 16.33 ft 2 8.84 -4.82 8.84 3.31 Dsgn. L = 2.75 ft 3 -2.56 2.56 1.15 +1.105D+0.750L+0.750S Dsgn, L = 6.00 ft 1 4.67 4.67 9.89 Dsgn. L = 16.33 ft 2 34.54 4.67 34.54 9.89 Dsgn. L = 2.75 ft 3 -2.48 2.48 1.12 wo +0.60D Dsgn. L = 6.00 ft 1 -2.54 2.54 1.74 Dsgn. L = 16.33 ft 2 4.65 -2.54 4.65 1.74 Dsgn. L = 2.75 ft 3 -1.35 1.35 0.61 +0-460D Dsgn. L = 6.00 ft 1 -1.95 1.95 1.34 Dsgn. L = 16.33 ft 2 3.57 -1.95 3.57 1.34 Dsgn. L = 2.75 ft 3 -1.03 1.03 0.46 Overall Maximum Deflections 140 Load Combination Span Max. Defl Location in Span Load Combination Max. 'Y' Defl Location in Span 0 1 0.0000 0,000 +D+0.750L+0.750S -0.6088 0.000 1 +D+0,750L+0.750S 2 0.5675 8.270 0.0000 0.000 3 0.0000 8,270 +D+0.750L+0.750S -0.2920 2.750 Md Vertical Reactions Support notation Far left is #1 Values in KIPS 04 Load Combination Support 1 Support 2 Support 3 Support 4 Overall MAXimum 10.708 10.436 1011110 Overall MINimum 2.420 2.464 D Only 4.033 4.106 +D+L 9.451 9.198 +D+S 7.515 7.454 Mull +D+0.750L+0.750S 10.708 10.436 +0.60D 2.420 2.464 L Only 5.418 5.092 S Only 3.483 3.347 IN wo . �wd File= SAJobs\s1ffis1811W811020- 917 Pine Streeko 1812030-enercalc trib 180131-ed General Beam Analysis ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.17.2.2E Lic. #: KW-06006655 Licensee: SOUND STRUCTURAL SOLUTIONZ Description : (2-11) C General Beam Properties Elastic Modulus 29,000.0 ksi Span #1 Span Length = 6.0 ft Area = 10.0 in A 2 Moment of Inertia = 100.0 in A 4 Span #2 Span Length = 16.333 ft Area = 10.0 in A 2 Moment of Inertia = 100.0 in A 4 Span #3 Span Length = 2.750 ft Area = 10.0 in A 2 Moment of Inertia = 100.0 in A 4 DY) 0,0� U�� D(O.285).S(O.356) D(014) S 0.175) D(O.36) Q( 2) D(0204) D(0.54)Ql0.1N%f0%�(0.882) S(O.918) V Span &0 ft Span = 16.333 ft Span = 2.750 ft Applied Loads Service loads entered. Load Factors will be applied for calculations. Load for Span Number 1 Uniform Load: D = 0.020, S = 0.0250 ksf, Tributary Width = 7.0 ft, (ROOF) Point Load : D = 0.2850, S = 0,3560 k @ 0.0 ft, ((2-3)) Load for Span Number 2 Uniform Load : D = 0.020 ksf, Tributary Width = 6.0 ft, (ROOF) Point Load: D = 0.360 k @ 3.250 ft, ((2-6)) Point Load: D = 0,2040 k @ 12.50 ft, ((2-8)) Uniform Load : D = 0.020 ksf, Tributary Width = 9.0 fl, (ROOF DECK) Load for Span Number 3 Uniform Load : D = 0.020, S = 0.0250 ksf, Tributary Width = 6.0 ft, (ROOF) Point Load : D = 0.540 k @ 0.0 ft, ((2-9)) Uniform Load : D = 0.020, L = 0.060, S = 0.0250 k/ft, Tributary Width = 1.0 ft, (ROOF DECK) Point Load: D = 0.6250, L = 0.8820, S = 0.9180 k @ 2.750 fi, ((2-10)) DESIGN SUMMARY Maximum Bending 9.516 k-fit Maximum Shear = 3.315 k Load Combination +D+S Load Combination +1.140D Location of maximum on span 6.000ft Location of maximum on span 6.000 ft Span # where maximum occurs Span # 1 Span # where maximum occurs Span # 1 Maximum Deflection Max Downward Transient Deflection 0.166 in 864 Max Upward Transient Deflection -0.087 in 2262 Max Downward Total Deflection 0.122 in 1612 Max Upward Total Deflection -0.057 in 1158 Maximum Forces & Stresses for Load Combinations Load Combination Max Stress Ratios Summary of Moment Values Summary of Shear Values Segment Length Span # M V Mmax + Mmax - Ma - Max Mnx Mnx/Omega Cb Rm Va Max Vnx Vnx/Omega Overall MAXimum Envelope Dsgn. L = 6.00 ft 1 -9.52 9�52 3,31 Dsgn. L = 16.33 ft 2 8.84 -9.52 9.52 3.31 Dsgn. L = 2.75 ft 3 -6.86 6.86 2.95 D Only Dsgn. L = 6.00 ft 1 -4.23 4.23 2.91 Dsgn. L = 16.33 ft 2 7.76 4.23 7.76 2.91 Dsgn. L = 2.75 ft 3 -2.25 2.25 1.01 +D+L Dsgn. L = 6.00 ft 1 -4.23 4.23 2.75 Dsgn. L = 16.33 ft 2 6.42 -4.90 6.42 2.75 Dsgn. L = 215 ft 3 -4.90 4.90 2.06 +D+S Dsgn. L = 6.00 ft 1 -9.52 9.52 3.04 Dsqn. L = 16.33 ft 2 3.59 -9.52 9.52 3.04 Dsgn. L = 2.75 ft 3 -5.43 5.43 2.41 +D+0.750L+0.750S Dsgn. L = 6.00 ft 1 -8.19 8.19 2.88 Dsgn. L = 16.33 ft 2 3.58 -8.19 8.19 2.88 W low %ME PW P0 100 ON bow P" am on, am so low vow I -General Beam Analysis File= S:Uobs1s1&s1811ks1811020-9i7 Pine Streefiwo 181203\2F_enercalctrib 180131-ed ENERCALC, INC. 1983-2017, Build:6.17-2.28, Ver:6-17.2.2E HIM, '-KW.66006655 Licensei: SOUND STRUCTURAL SEEK, Description (2-11) C 00 Load Combination Max Stress Ratios Summary of Moment Values Summary of Shear Values - Segment Length Span # M ... V Mmax + Mmax - Ma - Max Mnx Mnx/Omega Cb Rm Va Max Vnx Vnx/Ornega 140 Dsgn. L = 2.75 ft 3 -6.63 6.63 2.84 +1. 1 40D Dsgn. L = 6.00 It 1 -4.82 4.82 3.31 Dsgn. L = 16.33 It 2 8.84 4.82 8.84 3.31 Dsgn. L = 2.75 ft 3 -2.56 2.56 1.15 1.1 05D+0.750L+0.750S Dsgn. L = 6.00 ft 1 -8.64 8.64 3.19 Dsgn. L = 16.33 ft 2 4.39 -8.64 8.64 3.19 Dsgn. L = 2.75 It 3 -6.86 6.86 2.95 +0.60D Dsgn. L = 6.00 ft 1 -2.54 2.54 1.74 Dsgn. L = 16.33 ft 2 4.65 -2.54 4.65 1.74 Dsgn. L = 2.75 ft 3 -1.35 1.35 0.61 -fO.460D Dsgn. L = 6.00 ft 1 -1.95 1.95 1.34 Dsgn. L = 16.33 ft 2 3.57 -1.95 3.57 1.34 Dsgn. L = 2.75 ft 3 -1.03 1.03 0.46 Overall Maximum Deflections Load Combination Span Max. Defl Location in Span Load Combination Max. 'Y' Defl Location in Span S Only 1 0.1664 0.000 0.0000 Oi.000 D Only 2 0.1215 8,477 S Only -0.0295 1,447 3 0.0000 8.477 D Only -0.0569 2.750 Vertical Reactions Support notation Far left is #1 Values in KIPS Load Combination Support I Support 2 Support 3 Support 4 Overall MAXimurn 5.567 5.966 00 Overall MINimurn -0.162 1.209 D Only 4.033 4.106 +D+L 3.870 5.316 +D+S 5.567 5.377 +D+0.750L+0.750S 5.062 5.966 +0.60D 2.420 2.464 L Only -0.162 1.209 S Only 1.535 1.271 00 General Beam Analysis Description (2-14) General Beam Properties Elastic Modulus 29,000.0 ksi Span #1 Span Length File= S.UobAs181s18111s1811020 - 917 Pline Streefto 1811203118120321Fenercalc trib_08111020.ed ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.17.2.2f Licensee: SOUND STRUCTURAL SOLUTIONS 12.50 ft Area = 10.0 in A 2 Moment of Inertia = 100.0 in A 4 Q(0.255� S(O.425) XSpan = 12.50 ft k plied Loads Service loads entered. Load Factors will be applied for calculations. Uniform Load: D = 0.0150, S = 0.0250 ksf, Tributary Width = 17.0 ft, (ROOF) DESIGN SUMMARY Maximuni-Elendding 13.281 k-ft Maximum Shear 4.250 k Load Combination +D+S Load Combination +D+S Location of maximum on span 6.250ft Location of maximum on span 0.000 ft Span # where maximum occurs Span # 1 Span # where maximum occurs Span # 1 Maximum Deflection Max Downward Transient Deflection 0.081 in 1848 Max Upward Transient Deflection 0.000 in 0 Max Downward Total Deflection 0.130 in 1155 Max Upward Total Deflection 0.000 in 0 Maximum Forces & Stresses for Load Combinations Load Combination Max Stress Ratios Summary of Moment Values Summary of Shear Values Segment Length Span # M V Mmax + Mmax - Ma - Max Mnx Mnx1Omega Cb Rm Va Max Vnx Vnx/Ornega Overall MAXimum Envelope Dsgn. L = 12.50 ft 1 13.28 13.28 4.25 D Only Dsgn. L = 12.50 ft 1 4.98 4.98 1.59 +D+S Dsgn. L = 12.50 It 1 13.28 13,28 4.25 +D+0.750S Dsgn. L = 12.50 ft 1 11.21 11.21 3.59 +1.140D Dsqn. L = 12.50 ft 1 5.68 5,68 1.82 +1.105D+0.750S Dsqn. L = 12.50 ft 1 11.73 11.73 3.75 +0.60D Dsgn. L = 12.50 It 1 2.99 2.99 0.96 +0.460D Dsgn. L = 12.50 It 1 2.29 2.29 0.73 Overall Maximum Deflections Load Combination Span Max . ..... Def] Location in Span Load Combination Max. "+" Defl Location in Span +D+S Yertical Reactions 1 0.1298 6.313 Support notafion Far left is #1 0,0000 0.000 Values in KIPS Load Combination Support 1 Support 2 Overall MAXimum 4.250 4.250 Overall MINimum H56 0.956 D Only 1.594 1.594 +D+S 4.250 4.250 +D+0.750S 3.586 3.586 4601) 0-956 0.956 S Only H56 2.656 k.0 woo File= S.*Uobs1s181s18111s1811020 -917 Pine Streefto 1812031181203 - 2F - enercalc trib s1811020.0 General Beam Analysis ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.172:2( 4ic.#:'IKW-06006655 ticenseez SOUND STRUCTURAL SOLUT141 I)escription : (2-15) General Beam Properties Elastic Modulus 29,000.0 ksi Span #1 Span Length 16.333 ft Area 10.0 inA2 Moment of Inertia 100.0 inA4 low F 1W D(O.25§1 S(D.425) kum Span = 16.333 ft IN jkppli�d Loads Service loads entered. Load �7actors will be applied for calculations. Uniform Load: D = 0.0150, S 0.0250 ksf, Tributa� Width = 17.0 ft, (ROOF) DESIGN SUMMARY Maximum Bending 22.676 k-ft Kaxinnum Shear 5.553 k Load Combination +D+S Load Combination +D+S go Location of maximum on span 8.167ft Location of maximum on span 0.000 It Span # where maximum occurs Span # 1 Span # where maximum occurs Span # 1 Maximum Deflection Max Downward Transient Deflection 0.237 in 828 Max Upward Transient Deflection 0.000 in 0 Max Downward Total Deflection 0.378 in 517 L Max Upward Total Deflection 0.000 in 0 Maximum Forces & Stresses for Load Combinations Load Combination Max Stress Ratios Summary of Moment Values Summary of Shear Values - Segment Length Span # M V Mmax + Mmax - Ma - Max Mnx Mnx/Omega Cb Rm Va Max Vnx Vnx/Omega Overall MAXimurn Envelope Dsgn. L = 16.33 ft 1 22.68 22.68 5.55 D Only Dsqn. L = 16.33 ft 1 8.50 8.50 2.08 +D+S J1111111111 Dsgn. L = 16.33 ft 1 22.68 22.68 5.55 +ID+0.750S 6W Dsgn. L = 16.33 ft 1 19.13 19.13 4.69 +1.140D Dsgn. L = 16.33 ft 1 9.69 9.69 2.37 +,1.105D+0.750S Dsgn. L = 16.33 ft 1 20.03 20.03 4.90 +0.60D Dsgn. L = 16.33 ft 1 5.10 5.10 1.25 +0.460D Dsgn. L = 16.33 ft 1 3.91 3.91 0.96 Overall Maximum Deflections Load Combination Span Max . ..... Defl Location in Span Load Combination, Max. 'Y' Defi Location in Span Ob +D+S 1 0.3785 8.248 0.0000 0.000 Vertical Reactions Support notation: Farleftis#1 Values in KIPS Load Combination Support 1 Support 2 Overall MAXimurn 5.553 5.553 Overall MINimum 1.249 1.249 D Only 2.082 2.082 +D+S 5.553 5.553 +D+0.750S 4.686 4.686 +0.60D 1.249 1.249 S Only 3.471 3.471 M, �nw File =SAJobs�s1ffis181%1811020-917 Pine Street\wo 181203\2F_enerealctjib 180131-�W General Beam Analysis ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.17.2.2f 7 Lie. # : KW-06006655 Licensee: SOUND STRUCTURAL SOLUTIONS Description : (2-19) A General Beam Properties Elastic Modulus 29,000.0 ksi Span #1 Span Length = 2.0 ft Area = 10.0 in'12 Moment of Inertia = 100.0 in A 4 Span #2 Span Length = 6.0 ft Area = 10.0 in A 2 Moment of Inertia = 100.0 in A 4 D(O.168 S(O.21) D(O.36) L(1.08) S(O.45) I D(014j(0.175) D(0.18LJV)S(0225) Q(0.021 V16) S(O.025) Span = 2.0 R Span = 6.0 ft Applied Loads Service loads entered. Load Factors will be applied for calculations. Load for Span Number 1 Uniform Load: D = 0.020, S = 0,0250 ksf, Tributary Width = 7.0 ft, (ROOF) Point Load : D = 0.1680, S = 0.210 k 0, 0.0 ft, ((2-1)) Load for Span Number 2 Uniform Load: D = 0.020, L = G.060, S = 0.0250 k/ft, Extent = 0.0 -->> 3.250 ft, Tributary Width = 1.0 ft, (ROOF DECK) Point Load: D = 0.360, L = 1.080, S = 0.450 k @ 3.250 ft, ((2-6)) Uniform Load: D = 0.020, L = G.060, S = 0.0250 ksf, Extent = 3.250 -> 6.0 ft, Tributary Width = 9.0 ft, (ROOF DECK) DESIGN SUMMARY Maximum Bending 3.523 k-ft Maximum Shear 2.341 k Load Combination +D+L Load Combination +1.105D+0.750L+0.750S Location of maximum on span 3.277ft Location of maximum on span 6.000 ft Span # where maximum occurs Span # 2 Span # where maximum occurs Span # 2 Maximum Deflection Max Downward Transient Deflection 0.006 in 12765 Max Upward Transient Deflection -0.005 in 8928 Max Downward Total Deflection 0.007 in 10752 Max Upward Total Deflection -0-005 in 9120 Maximum Forces & Stresses for Load Combinations Load Combination Max Stress Ratios Summary of Moment Values Summary of Shear Values Segment Length Span # M V Mmax + Mmax - Ma - Max Mnx Mnx/Omega Cb Rm Va Max Vnx Vnx/Omega Overall MAXimum Envelope Dsgn. L = 2.00 ft 1 -1.39 1.39 1.61 Dsgn. L = 6.00 ft 2 3.52 -1.39 3.52 2.34 D Only Dsgn. L = 2.00 ft 1 -0.62 0.62 0.45 Dsgn. L = 6.00 ft 2 0.67 -0.62 0.67 0.49 +D+L Dsgn. L = 2.00 ft 1 -0.62 0.62 1.41 Dsgn. L = 6.00 ft 2 3.52 -0.62 3.52 2.27 +D+S Dsgn. L = 2.00 ft 1 -1.39 1.39 1.01 Dsgn. L = 6.00 ft 2 1.51 -1.39 1.51 1.11 +D+0.750L+0.750S Dsgn. L = 2.00 ft 1 -1.19 1.19 1.56 Dsgn. L = 6.00 ft 2 3.44 -1.19 3.44 2.29 +1.140D Dsgn. L = 2.00 ft 1 -0.70 0.70 0.51 Dsgn. L = 6.00 ft 2 0.76 -0.70 0.76 0.56 +1.1 05D+0.750L+0.750S Dsgn. L = 2.00 ft 1 -1.26 1.26 1.61 Dsgn. L = 6.00 ft 2 3,51 -1.26 3.51 2.34 +0.60D Dsgn. L = 2.00 ft 1 -0.37 0.37 0.27 Dsgn. L = 6.00 ft 2 0.40 -0.37 0.40 0.29 +0.460D Dsgn. L = 2.00 ft 1 -0.28 0.28 0.21 Dsgn. L = 6.00 ft 2 0.31 -0.28 0.31 0.23 ,General Beam Analysis File= SAJoWs181s1811Xs1811020-917 Pine Street\wo 181203QF-enercalc trib 180131-.ec:( ENERPALC, INC. 1983-2017, Build:6.17.2.28, Ver:6,17.2.2t 1--ic. #: 1KW-06006655 Licensee SOUND STRUCTURAL SOLUTIJ Description : (2-19) A Overail Maximum Deflections Load Combination Span Max.'�-" Defi Location in Span Load Combination Max. 'Y' Defl Location in Span 1 0.0000 0.000 L Only -0.0054 0.000 +D+L 2 0.0067 3.231 0.0000 0.000 Vertical Reactions Support notation Far left is #1 Values in KIPS Load Combination Support I Support 2 Support 3 Overall MAXimum 2.431 2.289 Overall MINimum 0.526 0.295 D Only 0.877 0.492 +D+L 1.854 2.274 +D+S 1.972 1.106 +D+0.750L+0.750S 2.431 2.289 +0.60D 0.526 0.295 L Only 0.978 1.783 S Only 1.096 0.614 File= S:Uobs\s18\s1811\s1811020- 917 Pine Streefto 181203\2F_enercalc trib 180131.ed General Beam Analysis ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.17.2.2i Lic. #: KW-06006655 Licensee: SOUND STRUCTURAL SOLUTION4 Description : (2-19) C General Beam Properties Elastic Modulus 29,000.0 ksi Span #1 Span Length = 2.0 ft Area = 10.0 in A 2 Moment of Inertia = 100.0 in A 4 Span #2 Span Length = 6.0 ft Area = 10.0 in A 2 Moment of Inertia = 100.0 in A 4 D(O.168 S(0.21) D(O.36 D(0,14f.175) Df V, Span = 2.0 ft Span = 6.0 ft Applied Loads Service loads entered. Load Factors will be applied for calculations. Load for Span Number 1 Uniform Load: D = 0.020, S = 0.0250 ksf, Tributary Width = 7.0 ft, (ROOF) Point Load : D = 0.1680, S = 0.210 k @ 0.0 ft, ((2-1)) Load for Span Number 2 Uniform Load: D = 0.020 k/ft, Extent = 0.0 -->> 3.250 ft, Tributary Width = 1.0 ft, (ROOF DECK) Point Load : D = 0.360 k @ 3.250 ft, ((2-6)) Uniform Load : D = 0.020 ksf, Extent 3.250 6.0 ft, Tributary Width = 9.0 ft, (ROOF DECK) DESIGN SUMMARY Maximum Bending 1.386 k-ft Maximum Shear 1.008 k Load Combination +D+S Load Combination +D+S Location of maximum on span 2.000ft Location of maximum on span 2.000 ft Span # where maximum occurs Span # 1 Span # where maximum occurs Span # I Maximum Deflection Max Downward Transient Deflection 0.002 in 20164 Max Upward Transient Deflection -0.001 in 66616 Max Downward Total Deflection 0.002 in 19252 Max Upward Total Deflection -0-000 in 169629 Maximum Forces & Stresses for Load Combinations Load Combination Max Stress Ratios Summary of Moment Values Summary of Shear Values Segment Length Span # IM V Mmax + Mmax - Ma - Max Mnx Mnx/Omega Cb Rm Va Max Vnx Vnx/Onnega Overall MAXimum Envelope Dsgn. L = 2.00 ft 1 -1.39 1.39 1.01 Dsgn. L = 6.00 ft 2 0.76 -1.39 1.39 0.57 D Only Dsgn. L = 2.00 ft 1 -0.62 0.62 0.45 Dsgn. L = 6.00 ft 2 0.67 -0.62 0.67 0.49 +D+S Dsgn. L = 2.00 ft 1 -1.39 1.39 1.01 Dsgn. L = 6.00 ft 2 0.37 -1.39 1.39 0.56 +D+0.750S Dsgn. L = 2.00 ft 1 -1.19 1.19 0.87 Dsgn. L = 6.00 ft 2 0.43 -1.19 1.19 0.52 +1.140D Dsgn. L = 2.00 ft 1 -0.70 0.70 0.51 Dsgn. L = 6.00 ft 2 0.76 -0.70 0.76 0.56 +1.105D+0.750S Dsgn. L = 2.00 ft 1 -1.26 1.26 0.92 Dsgn. L = 6.00 ft 2 0.50 -1.26 1.26 0.57 +0.60D Dsgn. L = 2.00 ft 1 -0.37 0.37 0.27 Dsgn. L = 6.00 It 2 0.40 -0.37 0.40 0.29 +0.460D Dsgn. L = 2.00 ft 1 -0.28 0.28 0.21 Dsgn. L = 6.00 ft 2 0.31 -0.28 0.31 0.23 General Beam Analysis File= SAJobs\s1ft1811Xs1811020- 917 Fine Streeftwo 181203X2F_enerealc trib 180131 ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.114!j �ic. # : KW-06006655 Licensee SOUND STRUCTURAL SOLUTIlle Description : (2-19) C Overall Maximum Deflections Load Combination Span Max. Defl Location in Span Load Combination Max. 'Y' Defl Location in Span +D+S 1 0,0025 0.000 0.0000 0.000 D Only 2 0.0011 3.462 S Only -0.0011 2.538 Vertical Reactions Support notation : Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Support 3 Overall MAXimum 1.565 0.492 Overall MINinnum 0.526 -0.128 D Only 0.877 0.492 +D+S 1.565 0.363 +D+0,750S 1.393 0.395 +0.60D 0.526 0.295 S Only 0.688 -0.128 File =S:Wobs\s1ft1811\s1811020 -917 Pine Streefto 181203\2F-enercalot(ib 180131-ed General Beam Analysis ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.17.2.2E Lic. #: KW-06006655 Licensee: SOUND STRUCTURAL SOLUTION! Description : (2-19) E General Beam Properties Elastic Modulus 29,000.0 ksi Span #1 Span Length 2.0 ft Area 10.0 in A 2 Moment of Inertia 100.0 in A 4 6011 0(0.168! S(O.21) D(O.14) S(O.175) Span = 2.0 ft Applied Loads Service loads entered. Load Factors will be applied for calculations. Uniform Load: D = 0.020, S = 0.0250 ksf, Tributary Width = 7.0 ft, (ROOF) Point Load: D = 0.1680, S = 0.210 k @ 0.0 ft, ((2-1)) DESIGN SUMMARY Maximum Bending 1.386 k-ft Maximum Shear 1.008 k Load Combination +D+S Load Combination +D+S Location of maximum on span 2.000ft Location of maximum on span 2.000 ft Span #where maximum occurs Span # 1 Span # where maximum occurs Span # 1 Maximum Deflection Max Downward Transient Deflection 0.000 in 0 Max Upward Transient Deflection 0.000 in 0 Max Downward Total Deflection 0.001 in 49002 Max Upward Total Deflection 0.000 in 0 Maximum Forces & Stresses for Load Combinations Load Combination Max Stress Ratios Summary of Moment Values Summary of Shear Values Segment Length Span # M V Mmax + Mmax - Ma - Max Mnx Mnx/Omega Cb Rm Va Max Vnx Vnx/Omega Overall MAXimum Envelope Dsgn. L = 2.00 ft 1 -1.39 1.39 1.01 D Only Dsgn. L = 2.00 ft 1 -0.62 0.62 0.45 +D+S Dsgn. L = 2.00 ft 1 -1.39 1.39 1.01 +D+0.750S Dsgn. L = 2.00 ft 1 -1.19 1.19 0.87 +1.140D Dsgn. L = 2.00 It 1 -0.70 0,70 0.51 +1.105D+0.750S Dsgn. L = 2.00 ft 1 -1.26 1.26 0.92 +0.60D Dsgn. L = 2,00 It 1 -0.37 0.37 0.27 +0.460D Dsgn. L = 2.00 It 1 -0.28 0.28 0.21 Overall Maximum Deflections Load Combination Span Max. Defl Location in Span Load Combination Max. 'Y' Dell Location in Span +D+S Vertical Reactions 1 0.0010 0.000 Support notation : Far left is #1 0.0000 0.000 Values in KIPS Load Combination Support I Support 2 Overall MAXimum 1.008 Overall MINimum 0.269 D Only 0.448 +D+S 1.008 +D+0.750S 0.868 +0.60D 0.269 S Only 0,560 M %=6 Fqj r@i r 777 W-W GRAVITY ANALYSIS Overstrength Calculations 6628 212th Street SW, Suite 205 - Lynnwood, WA 98036 - Ph: 425-778-1023 - Fax: 206-260-7490 law OR aw P4 4W File= S:\Jobsks18\s1811\s1811020 - 917 Pine Streefto 181203\181203 I F_enercalc trits1811020.ed Steel Beam ENERCALC, INC. 1983-2017, Build:6.17.2.28. Ver:6.17.2.2E Description : (11 -7) A overturn ow CODE REFERENCES Calculations per AISC 360-10, 1 BC 2015, ASCE 7-10 Load Combination Set: IBC 2015 Material Properties Analysis Method: Allowable Strength Design Fy: Steel Yield: 50.0 ksi Beam Bracing : Beam is Fully Braced against lateral -torsional buckling E: Modulus: 29,000.0 ksi Bending Axis: Major Axis Bending Span 12.0 ft Span 6.0 ft W12x22 W12x22 Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Load for Span Number 1 Uniform Load D = 0.0150, L = 0.040 ksf, Tributary Width = 9.0 ft, (FLOOR) Uniform Load D = 0.020, L = 0.060, S = 0.0250 ksf, Tributary Width = 6.0 ft, (ROOF DECK) Point Load : W = 1.422, E 4339 k @ 0.0 ft, (overturn) Load(s) for Span Number 2 Point Load : D = 0.1070, L G.04350, S = 0.1780 k @ 6.0 ft, ((1-5)) Uniform Load: D = 0.020, L = 0.060, S = 0.0250 ksf, Tributary Width = 15.0 ft, (ROOF DECK) Point Load : D = 0.1830, L = 0.5480, S = 0.2280 k @ 6.0 ft, ((1-3)) DESIGN SUMMARY maximu-m-Bending Stress Ratio 0.403: 1 Maximum Shear Stress Ratio 0.137 1 Section used for this span W12x22 Section used for this span W12x22 Ma: Applied 29.475 k-ft Va: Applied 8.761 k Mn / Omega: Allowable 73.104 k-ft Vn/Omega: Allowable 63.960 k Load CombinNW+0.750L+0.750S+0.8925E, LL Comb Run (LL) Load CombinbDMD+0.750L+0.75OS-0.8925E, LL Comb Run (1) Location of maximum on span 12.000ft Location of maximum on span 12.000 ft Span # where maximum occurs Span # 1 Span # where maximum occurs Span # 1 Maximum Deflection Max Downward Transient Deflection 0.253 in Ratio = 569 ­360 Max Upward Transient Deflection -0.119 in Ratio = 1,212 ­360 Max Downward Total Deflection 0.310 in Ratio = 465 ­180 Max Upward Total Deflection -0.070 in Ratio = 2059 >=180 X0 am on bw W aw Overall Maximum Deflections Load Combination Span Max. "-" Defi Location in Span Load Combination Max. "+"Defl Location in Span so +D+L 1 0.0767 5.760 +D+L -0.0699 7.440 +D+0.750L+0.75OS-0.5250E 2 0.3097 6.000 0.0000 7.440 WA Vertical Reactions Support notation Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Support 3 U4 Overall MAXimum 6.554 16.424 *AM Overall MINimum 0.082 2.529 D Only 0.935 4.215 +D+L, LL Comb Run (1) -0.711 11.852 +D+L, LL Comb Run (L*) 5.255 8.535 +D+L, LL Comb Run (LQ 3.609 16.172 +D+S 1.070 8.537 +D+0.750L+0.750S, LL Comb Run (*L) -0.198 13.184 +D+0.750L+0.750S, LL Comb Run (L*) 4.276 10.696 +D+0.750L+0.750S, LL Comb Run (ILL) 3.042 16.424 +D+0.60W 1.788 4.215 +D-0.60W 0.082 4.215 +D+0.70E 3.972 4.215 Steel Beam Description (1 -7) A overturn Vertical Reactions Load Combination Support 1 +D-0.70E -2.102 +D+0J50L+0.750S+0.450W, LL Comb R 0,441 +D+0.750L+0.750S+0.45OW, LL Comb R 4.916 +D+0.750L+0.750S+0.45OW, LL Comb R 3.681 +D+0.750L+0.75OS-0.45OW, LL Comb Ri -0.838 +D+0.750L+0.75OS-0.45OW, LL Comb Ri 3.636 +D+01501-475OS-0.450W, LL Comb Ri 2.402 +D+0.750L+0.750S+0.5250E, ILL Comb F 2.080 +D+0.750L+0.750S+0.5250E, LL Comb F 6.554 +D+0.750L+0.750S+0.5250E, LL Comb F 5.320 +D+0.750L+0.75OS-0.5250E, LL Comb R -2.476 +D+0.750L+0.75OS-0.5250E, LL Comb R 1.998 +D+0.750L+0.75OS-0.5250E, LL Comb R 0.764 +0.60D+0.60W 1.414 +0.60D-0.60W -0.292 +0.60D+0.70E 3.598 +0.60D-0.70E -2.476 L Only, LL Comb Run (*L) -1.646 L Only, LL Comb Run (L*) 4.320 L Only, ILL. Comb Run (LL) 2.674 S Only 0.135 W Only 1.422 -W -1.422 E Only 4.339 E Only * -1.0 -4.339 Support 2 4.215 13.184 10.696 16.424 13.184 10.696 16.424 13.184 10.696 16.424 13.184 10.696 16.424 2.529 2.529 2.529 2.529 7.637 4.320 11-957 4.322 0.000 -0.000 Support 3 File= S:1Jobsks181s18Ws1811020- 917 Pine Sbwtkwo 1812031181203 1F-enercalc tri�_s`1811020.ecl ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.17.2.2E Support notation : Far left is #1 Values in KIPS Steel Beam Description : (1 -7) A overstrength CODE REFERENCES Calculations per AISC 360-10, 1 BC 2015, ASCE 7-10 Load Combination Set: IBC 2015 Material Properties Analysis Method: Allowable Strength Design Beam Bracing: Beam is Fully Braced against lateral -torsional buckling Bending Axis: Major Axis Bencring He= SMobsW81s1811108111020 - 9117 Pine AN aw INC. 1983-2017, Build:6.17.2.28, Ver:6.17.2.2F 1 110 Fy: Steel Yield: 50.0 ksi E: Modulus : 29,000.0 ksi Span 12.0 ft Span 6-0 8 WUM W12.22 )plied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Load for Span Number I Uniform Load: D = 0.0150, L = 0.040 ksf, Tributary Width = 9.0 ft, (FLOOR) Uniform Load: D = 0.020, L = 0-060, S = 0.0250 ksf, Tributary Width = 6.0 ft, (ROOF DECK) Point Load: W = 1.422, E = 8.344 k @ 0.0 ft, (overturn) Load(s) for Span Number 2 PointLoad: D=0.1070, L=0.04350, S=0.1780k@6.0ft,((1-5)) Uniforml-oad: D=0.020, L=0.060, S=0.0250ksf, Tributary Width= 15.0 ft, (ROOF DECK) PointLoad: D=0.1830, L=0.5480, S=0.2280k@6.Oft,((1-3)) DESIGN SUMMARY Maximum Bending Stress 0.403: 1 Maximum Shear Stress Ratio 0.137:1 Section used for this span W12x22 Section used for this span W1 2x22 Ma: Applied 29.475 k-ft Va: Applied 8.761 k Mn / Omega: Allowable 73.104 k-ft Vn/Omega: Allowable 63.960 k Load CombiT(aOND+0.750L+0.750S+1.313E, LL Comb Run (LL) Load CombinbM9D+0.750L+0.750S+1.313E, LL Comb Run (LL) Location of maximum on span 12.000ft Location of maximum on span 12.000 ft Span # where maximum occurs Span # I Span # where maximum occurs Span # 1 Maximum Deflection Max Downward Transient Deflection 0.253 in Ratio = 569 >= Max Upward Transient Deflection -0.119 in Ratio = 1,212 >= Max Downward Total Deflection 0.310 in Ratio= 465 >= Max Upward Total Deflection -0.070 in Ratio= 2059 >= Overall Maximum Deflections Load Combination S[mn Max. "-" Defi Location in Span Load Combination Max. 'Y' Defi Location in Span +D+L 1 0.0767 5.760 +D+L -0.0699 7.440 +D+0.750L+0.75OS-0.5250E 2 0.3097 6.000 0.0000 7.440 Vertical Reactions Support notation : Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Support 3 Overall MAXimum 6.656 16.424 Overall MINimum 0.082 2.529 D Only D.935 4.215 +D+L, LL Comb Run (*L) -0.711 11.852 +D+L, LL Comb Run (L*) 5.255 8.535 +D+L, LL Comb Run (LL) 3.609 16.172 +D+S 1.070 8.537 +D+0.750L+0.750S, LL Comb Run (1) --0.198 13.184 +D+0.750L+0.750S, LL Comb Run (L*) 4.276 10.696 +D+0.750L+0.750S, LL Comb Run (LQ -3.042 16.424 +D+0.60W 1.788 4.215 +D-0.60W -0.082 4.215 +D+0.70E 6.776 4.215 ow Steel Beam He= S.AJobsslifti8lils'18111020-9117 Pine Sti 1812011811203 117jnercalc tr1bLs1811020.eC1 ENERCALC, INC. 1983-2017, Build:6.17.2.28. Ver.6.17.22f Description : (1 -7) A overstrength Vertical Reactions Support notation Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Support 3 +D-0.70E 4.906 4.215 +D+0.750L+0.750S+0.45OW, LL Comb R 0.441 13.184 +0+0.750L+0.750S+0.45OW, ILL Comb R 4.916 10.696 +D+0.750L+0.750S+0.45OW, LL Comb R 3.681 16.424 +D+0.750L+0.75OS-0.45OW, LL Comb Ri -0.838 13.184 +D+0.750L+0.75OS-0.45OW, LL Comb Ri 3.636 10.696 +D+0.750L+0.75OS-0.45OW, LL Comb Ri 2.402 16.424 +D+0.750L+0.750S+0.5250E, LL Comb F 4.182 13.184 +D+0.750L+0.750S+0.5250E, LIL Comb F 8.656 10.696 +D+0.750L+0.750S+0.5250E, LL Comb F 7.422 16.424 +D+0.750L+0.75OS-0.5250E, ILL Comb R -4.579 13.184 +D+0.750L+0.75OS-0.5250E, ILL Comb R -0.105 10.696 +D+0.750L+0.75OS-0.5250E, LL Comb R -1.339 16.424 +0.60D+0.60W 1.414 2.529 +0.60D-0.60W -0,292 2.529 +0.60D+0.70E 6,402 2.529 +0.60D-0.70E -5.280 2.529 L Only, ILL. Comb Run (*L) -1.646 7.637 L Only, ILL. Comb Run (L*) 4.320 4.320 L Only, ILL Comb Run (LL) 2,674 11.957 S Only 0.135 4.322 W Only 1.422 0.000 -W -1.422 -0.000 E Only 8.344 0.000 E Only * -1.0 -8.344 -0.000 File= S.Uobs\s1ft1811As1811020- 917 Pine Streetwo 11811201811203 1 F_enercelc tdb_s1811020ed Steel Beam ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.17.2.2E Lic. # : KW-06006655 Licensee: SOUND STRUCTURAL SOLUTIONS Description : (1 -7) C overtu rn CODE REFERENCES Calculations per AISC 360-10, IBC 2015, ASCE 7-10 ... Load CombInation Set : IBC 2015 Material Properties Analysis Method: Allowable Strength Design Fy: Steel Yield 50.0 ksi Beam Bracing: Beam is Fully Braced against lateral -torsional buckling E: Modulus: 29,000.0 ksi Bending Axis: Major Axis Bending Q( V 8) ---,+ D (L�l 2) W12X22 W12x22 Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Load for Span Number I Uniform Load: D = 0.0150 ksf, Tributary Width = 9.0 ft, (FLOOR) Uniform Load: D = 0.020 ksf, Tributary Width = 6.0 ft, (ROOF DECK) Uniform Load: D = 0.010 ksf, Tributary Width = 9.0 ft, (WALL) Uniform Load : D = 0.020 ksf, Tributary Width = 6.0 ft, (ROOF) Uniform Load: D = 0.020 ksf, Tributary Width = 9.0 ft, (ROOF DECK) Point Load: W = 1.422, E = 4.339 k @ 7.0 ft, (overturn) Load(s) for Span Number 2 PointLoad: D=0.1070, L=0.04350, S=0.1780k@6.0ft,((1-5)) Uniforml-oad: D=0.020, L=0.060, S=0.0250ksf, Tributary Width= 15.0 ft, (ROOF DECK) PointLoad: D=0.1830, L=a5480, S=0.2280k@6.0ft,((1-3)) DESIGN SUMMARY Maximum Bending Stress Ratio O�566: 1 Maximum Shear Stress Ratio 0.144:' Section used for this span W1 2x22 Section used for this span W1 2x22 Ma: Applied 41.392 k-ft Va : Applied 9.223 k Mn / Omega: Allowable 73.104 k-ft Vn/Omega: Allowable 63.960 k Load Combination +1.118D+1.190E Load Combination +1.089D+0.750L+0.750S+0.8925E Location of maximum on span 6.996ft Location of maximum on span 16.500 ft Span # where maximum occurs Span # 1 Span # where maximum occurs Span # 1 Maximum Deflection Max Downward Transient Deflection 0.321 in Ratio = 449 >=360 Max Upward Transient DefieGtion -0.157 in Ratio = 917 >=360 Max Downward Total Deflection 0.275 in Ratio= 523 >=180 Max Upward Total Deflection -0.270 in Ratio = 533 >=180 Overall Maximum Deflections Load Combination Span Max. "-" Defi Location in Span Load Combination Max. "+"Defl Location in Span +D+0.70E 1 0.2989 7.986 0.0000 0.000 L Only 2 0.3207 6.000 +D+0.70E -0.0897 1.896 Vertical Reactions Support notation Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Support 3 Overall MAXimum 6.637 16.611 Overall MINimum -0.557 -0.603 D Only 4.889 T844 +D+L 3.692 15.032 +D+S 4.332 11 �057 +D+0.750L+0.750S 3.573 15.645 +D+0.60W 5.380 8.206 +D-0.60W 4.397 7.482 +D+0.70E 6.637 9.133 +D-0.70E 3.140 6.555 low ON w4i met M %00 Steel Beam File= S:1JobsW8XsI81%181I020 -917 Pine SbWXwo 1812031181203 IF enercalctrib_s1811020.ed ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.17.22E Description : (1-7) C overturn oft Vertical Reactions Support notation Far left is #1 Values in KIPS :1 Load Combination Suppodl Support 2 Support 3 Mw +D+0.750L+0.750S+0.45OW 3.942 15.916 +D+0.750L+0.75OS-OA50W 3,205 15,373 +D+0.750L+0.750S+0.5250E 4.885 16.611 +D+0.750L+0.75OS-0.5250E 2.262 14.678 +0.60D+0.60W 3.424 5.068 +0.60D-0.60W 2.442 4.344 +0.60D+0.70E 4.682 5.995 +0.60D-0.70E 1.184 3.418 j L Only -1,197 7.188 S Only -0.557 3.213 W Only 0.819 0,603 -W -0.819 -0.603 E Only 2.498 1,841 E Only * -1.0 -2.498 -1.841 m6d jaw File= S:Uobs\s18\s1811\s1811020 - 9117 Pine StreetNwo 181203\181203 1F-enercalc tribLs1811020.ed Steel Beam ENERCALC, INC, 1983-2017, Build:6.17.2.28, Ver:6.17,2.2E Lic. #: KW-06006655 Licensee: SOUND STRUCTURAL SOLUTION! Description (1-7) C overstrength CODE REFERENCES Calculations per AISC 360-10, 113C. 2015, ASCE 7-10 Load Combination Set: IBC 2015 Material Properties Analysis Method: Allowable Strength Design Fy : Steel Yield: 50.0 ksi Beam Bracing : Beam is Fully Braced against lateral -torsional buckling E: Modulus: 29,000.0 ksi Bending Axis: Major Axis Bencing D(� 2) Q(V) ez Span 16.50 ft Span 6.0 ft W12x22 W1 2x22 Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Load for Span Number 1 Uniform Load: D = 0.0150 ksf, Tributary Width = 9.0 ft, (FLOOR) Uniform Load: D = 0.020 ksf, Tributary Width = 6.0 ft, (ROOF DECK) Uniform Load: D = 0.010 ksf, Tributary Width = 9.0 ft, (WALL) Uniform Load D = 0.020 ksf, Tributary Width = 6.0 ft, (ROOF) Uniform Load D = 0.020 ksf, Tributary Width = 9.0 ft, (ROOF DECK) Point Load : W = -1.422, E 344 k @ 7.0 ft, (overturn) Load(s) for Span Number 2 PointLoad: D=0.1070, L=0.04350, S=0.1780k@6.Oft,((1-5)) UniformLoad: D=0.020, L=0.060, S=0.0250ksf, Tributary Width= 15.0 ft, (ROOF DECK) PointLoad: D=0.1830, L=0.5480, S=0.2280k@6.Oft,((1-3)) DESIGN SUMMARY Maximum Bending Stress Ratio 0.683: 1 Maximum Shear Stress Ratio = 0.137 : 1 Section used for this span W1 2x22 Section used for this span W1 2x22 Ma: Applied 49.946 k-ft Va : Applied 8.761 k Mn / Omega: Allowable 73.104 k-ft Vn/Omega: Allowable 63.960 k Load Combination +0.4817D+1.750E Load Combination +1.089D+0.750L+0.750S+1.313E Location of maximum on span 6.996ft Location of maximum on span 16.500 ft Span # where maximum occurs Span # 1 Span # where maximum occurs Span # 1 Maximum Deflection Max Downward Transient Deflection 0.321 in Ratio= 449 -0.0 Max Upward Transient Deflection -0.302 in Ratio= 477 >=O.O Max Downward Total Deflection 0.351 in Ratio = 410 -0.0 Max Upward Total Deflection -0.372 in Ratio = 388 >=O.O L Overall Maximum Deflections Load Combination Span Max. Defl Location in Span Load Combination Max. 'Y' Defl Location in Span +D-0,70E 1 0.3967 7.986 0.0000 0.000 2 0.0000 7.986 +D-0.70E -0.3715 6.000 Vertical Reactions Support notation Far left is #1 Values in KIPS Load Combination Support I Support 2 Support 3 Overall MAXimum 8.251 17.503 Overall MINimum -0,430 0.603 D Only 4.889 7.844 +D+L 3.692 15.032 +D+S 4.332 11.057 +D+0.750L+0.750S 3.573 15.645 +D+0.60W 4.397 7.482 +D-0.60W 5.380 8,206 +D+0.70E 1.526 5.366 +D-0.70E 8.251 10.322 Steel Beam File= S.Uobs1s181s181%1811020 -917 Fine Streeftwo 181203\181203 IF_enercalc trib—s1811020.ed ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.17.2.2E Description : (1 -7) C overstrength Vertical Reactions Support notafion Far left is #1 Values in KIPS Load Combinafion Support I Support 2 Support 3 +D+0.750L+0.750S+0.45OW 3.205 15.373 +D+0.750L+0.75OS-0.45OW 3.942 15.916 +D+0.750L+0.750S+0.5250E 1.051 13.786 +D+0.750L+0.75OS-0.5250E 6.095 17.503 +0.60D+0.60W 2.442 4.344 +0.60D-0.60W 3.424 5.068 +0.60D+0.70E -0.430 Z228 +0.60D-0.70E 6.296 7.184 L Only -1.197 7.188 S Only -0.557 3.213 W Only -0.819 -0.603 -W 0.819 0.603 E Only -4.804 -3.540 E Only * -1.0 4.804 3.540 File= S:\Jobs\s18ks1811\s1811020 - 917 Pine Street\wo 181203\181203 1F—enercalc tdb_s1811020.ed Wood Beam ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.17.2.2t Lic. #: KW-06006655 Licensee: SOUND STRUCTURAL SOLUTIONS Description : (1-19) overturn CODE REFERENCES Calculations per INIDS 2015, 1 BC 2015, CBC 2016, ASCE 7-10 Load Combination Set: IBC 2015 Material Properties Analysis Method: Allowable Stress Design Fb - Tension 2,600.0 psi E: Modulus of Elasticity Load Combination IBC 2015 Fb - Compr 2,600.0 psi Ebend-xx 2,000.0 ksi Fc - PrIl 2,510. 0 psi Eminbend - xx 1,016.54ksi Wood Species Trus Joist Fc - Perp 750.0 psi Wood Grade MicroLam LVL 2.0 E Fv 285.0 psi Ft 1,555.0 psi Density 42.0 pcf Beam Bracing Beam is Fully Braced against lateral -torsional buckling tD(O.28 (0.35) T 3.500x14.000 Span = 16.0 ft D(O.28 V (0.35) Applied Loads Service loads entered. Load Factors will be applied for calculations. Uniform Load : D = 0.0150, L = 0.040, Tributary Width = 1.0 ft, (FLOOR) Point Load: D = 0.6830, S = 1.138, W = 0.5120, E = 1.491 k @ 3.750 ft, (FRH) Uniform Load : D = 0.010 ksf, Tributary Width = 9.0 ft, (WALL) Uniform Load: D = 0.020, S = 0.0250 ksf, Extent = 10.125 ­> 16.0 ft, Tributary Width = 14.0 ft, (ROOF) Point Load: D = 0.6830, S = 1.138, W = -0.5120, E = -1.491 k @ 10.125 ft, (FRH) Uniform Load: D = 0.020, S = 0.0250 ksf, Extent = 0.0 ­> 3.750 ft, Tributary Width = 14.0 ft, (ROOF) Maximurn Bending Stress Ratio 0.75a. 1 Maximum Shear Stress Ratio 0.534 : 1 Section used for this span 3.500x14.000 Section used for this span 3.500x14.000 fb : Actual 2,193.33 psi fv : Actual 175.03 psi P" FIB: Allowable 2,924.88 psi Fv: Allowable 327.75 psi Load Combination +D+S Load Combination +D+S um Location of maximum on span 10.102ft Location of maximum on span 16.000 ft Span # where maximum occurs Span # 1 Span # where maximum occurs Span # 1 am Maximum Deflection Max Downward Transient Deflection 0.301 in Ratio= 638 >=360 40 Max Upward Transient Deflection -0.042 in Ratio= 4567 ­360 Max Downward Total Deflection 0.606 in Ratio= 316 >=240. ON Max Upward Total Deflection 0.000 in Ratio 0 <240.0 Overall Maximum Deflections Load Combination Span Max. Defl Location in Span Load Combination Max. 'Y' Dell Location in Span +D+S 1 0.6060 8.175 0.0000 0.000 Reactions Support notation : Far left is #1 Values in KIPS INN —Verticall Load Combination Support 1 Support 2 Overall MAXimum 5.668 5.718 Overall MINimum -0.204 0.204 D Only 2.843 2.898 +D+L 3.163 3.218 Pip wo wow vim : ow File= SAJoWs18\s1811\s1811020-917 Pine Street'= 181203\181203 1F - enercalc 1Jib-s1811020.e(;( Wood Beam ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.17.2.2'f Description : (1 -19) overturn Vertical Reactions Support notation Far left is #1 Values in KIPS Load Combination Support I Support 2 +D+S 5.668 5.718 +D+0.750L+0.750S 5.202 5.253 +D+0.60W 2.965 2.776 +D-0.60W 2.720 3.021 +D+0.70E 3.259 2.482 +D-0,70E 2.427 3.314 +D+0.750L+0.750S+0.45OW 5.293 5.161 +D+0.750L+0.75OS-0.45OW 5.110 5.345 +D+0.750L+0.750S+0.5250E 5.514 4.941 +D+0.750L+0.750S-0.5250E 4.890 5.565 +0.60D+0.60W 1.828 1.617 +0.60D-0.60W 1.583 1,861 +0.60D+0,70E 2,121 1.323 +0.60D-0.70E 1,290 2.155 L Only 0.320 0.320 S Only 2.825 2.819 W Only 0.204 -0.204 -w -0.204 0.204 E Only 0.594 -0,594 E Only * -1.0 -0.594 0.594 File= S:\Jobs\s18\s181 I W8111020- 917 Pine Street\wo 18120181203 1F-enercalc trib_s1811020.ecf Nood Beam ENERGALC, INC. 1983-20W, Build:6.17.2.28, Ver:6.17.2.2f -ic. #: KW-06006655 Licensee: SOUND STRUCTURAL SOLUTION,' Description : (1 -19) overstrength CODE REFERENCES Calculations per NIDS 2015, IBC 2015, CBC 2016, ASCE 7-10 Load Combination Set: IBC 2015 Material Properties Analysis Method: Allowable Stress'Design Fb - Tension 2,600.0 psi E: Modulus of Elasticity Load Combination IBC 2015 Fb - Compr 2,600.0 psi Ebend-xx 2,000.0 ksi Fc - PrIl 2,510.0 psi Eminbend - xx 1,016.54ksi Wood Species Trus Joist Fc - Perp 750.0 psi Wood Grade MicroLam LVIL 2.0 E Fv 285.0 psi Ft 1,555.0 psi Density 42. 0 pcf Beam Bracing Beam is Fully Braced against lateral -torsional buckling f *DfO.28VIO.151 , 3.500x14.000 Span = 16.0 ft Q(0.28 VS(0.35) -Applied Loads — Service loads entered. Load Factors will be applied for calculations. Uniform Load : D = 0,0150, L = 0,040 , Tributary Width = 1.0 ft, (FLOOR) Point Load: D = 0,6830, S = 1.138, W = 0.5120, E = 1.491 k (@_ 3.750 ft, (FRH) Uniform Load : D = 0.010 ksf, Tributary Width = 9.0 ft, (WALL) Uniform Load: D = 0.020, S = 0.0250 ksf, Extent = 10. 125 ­> 16.0 ft, Tributary Width = 14.0 ft, (ROOF) Point Load : D = 0.6830, S = 1. 138, W = -0.5120, E = -2.868 k @ 10. 125 ft, (FRH) Uniform Load : D = 0,020, S = 0.0250 ksf, Extent = 0.0 ­> 3.750 ft, Tributary Width = 14.0 ft, (ROOF) Maximum Bending Stress Ratio 0.808: 1 Maximum Shear Stress Ratio 0.534 : 1 Section used for this span 3.500x14.000 Section used for this span 3.500x14.000 fb : Actual 3,289.50 psi fv : Actual 175.03 psi FB: Allowable 4,069.39 psi Fv: Allowable 327.75 psi Load Combination +1,089D+0.750L+0.75OS-1.313E Load Combination +D+S Location of maximum on span 10.102ft Location of maximum on span 16.000 ft Span # where maximum occurs Span # 1 Span # where maximum occurs Span # 1 Maximum Deflection Max Downward Transient Deflection 0.301 in Ratio = 638 >=O.O Max Upward Transient Deflection -0.155 in Ratio = 1234 >=O.O Max Downward Total Deflection 0.638 in Ratio = 300 >=O,O Max Upward Total Deflection 0.000 in Ratio = 0 >=O.O Overall Maximum Deflections Load Combination Span Max. "-" Defi Location in Span Load Combination Max. 'Y' DO Location in Span +D+0.750L+0.75OS-0.5250E 1 0.6381 8.350 0.0000 0.000 Vertical Reactions Support notation : Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Overall MAXimum 5.668 6.022 Overall MINimum -0.088 0.204 D Only 2.843 2.898 +D+L 3.163 3.218 PIN 'Wood Beam Description (1-19) overstrength Vertical Reactions Load Combination +D+S +D+0.750L+0.750S +D+0.60W +D-0.60W +D+0.70E +D-0,70E +D+0.750L+0.750S+0.45OW +D+0.750L+0.75OS-OA50W +D+0,750L+0.750S+0.5250E +D+0.750L+0.75OS-0.5250E +0.60D+0,60W +0.60D-0.60W +0.60D+0.70E +0.60D-0.70E L Only S Only W Only -w E Only E Only * -1.0 File= SAJobs\s18\s18Ms1811020-917 Pine Streetwo 181203\181203 1F-enercaIctrib_s1811020.et,4 ENIERCALC, INC. 1983-2017, Build:6.17.2.28, Ver.6.17.2.' 2f Support notation : Far left is #1 Values in KIPS Suppoql Support 2 5.668 5.718 5.202 5.253 2.965 2.776 2.720 3.021 2.905 1.873 2.781 3.924 5.293 5.161 5.110 5.345 5.248 4.484 5.155 6.022 1.828 1.617 1.583 1.861 1.768 0.713 1.644 2.765 0.320 0.320 2.825 2.819 0.204 -0.204 -0.204 0.204 0.088 -1.465 -0.088 1.465 File= SAJobs\s18\s181 I \0811020 - 917 Pine Street\wo 181203\181203 117_enercalc tr11b_s1811020.eC1 Nood Beam ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.17.2.2i -ic. # : KW-06006655 Licensee: SOUND STRUCTURAL SOLUTION.' Description : (1 -20) overturn CODE REFERENCES Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10 Load Combination Set: IBC 2015 Material Properties Analysis Method: Allowable Stress Design Fb - Tension 2,325.0 psi E: Modulus of Elasticity Load Combination IBC 2015 Fb - Compr 2,325.0 psi Ebend-xx 1,550.0 ksi Fc - Prll 2,170.0 psi Eminbend - xx 787.82 ksi Wood Species Trus Joist Fc - Perp 900.0 psi Wood Grade TimberStrand LSL 1.55E Fv 310.0 psi Ft 1,070.0 psi Density 44.990 pcf Beam Bracing Beam is Fully Braced against lateral -torsional buckling -I D(O.28) S(Q.3 ) ;jS1t)tj.491) D(O.683) S(I.138) YV(0.512) E(1.491) D(r) D(O.683) S(1.138) D(0_01jQ0_04) 1.7504 Span = 8.0 ft Applied Loads Service loads entered. Load Factors will be applied for calculations. Uniform Load: D = 0.0150, L = 0.04, Tributary Width = 1.0 ft, (FLOOR) Point Load : D = 0.6830, S = 1. 138, W = 0.5120, E = 1.491 k @ 0.50 ft, (FRH) Uniform Load: D = 0.010 ksf, Tributary Width = 9.0 ft, (WALL) Uniform Load: D = 0.020, S = 0.0250 ksf, Extent = 6.875 ­> 8.0 ft, Tributary Width = 14.0 ft, (ROOF) Point Load : D = 0.6830, S = 1.138, W = -0.5120, E = -1.491 k @ 6.875 ft, (FRH) Uniform Load : D = 0.020, S = 0.0250 ksf, Extent = 0.0 ­> 0.50 ft, Tributary Width = 14.0 ft, (ROOF) Maximunn Bending Stress Ratio 0.21e 1 Maximum Shear Stress Ratio 0.475 : 1 Now Section used for this span 1.75x14 Section used for this span 1.75x14 fb : Actual 570.22 psi fv : Actual 169.44 psi FB: Allowable 2,636.10 psi Fv: Allowable 356.50 psi Load Combination +D+S Load Combination +D+S Location of maximum on span 5.723 ft Location of maximum on span 8.000 ft Span # where maximum occurs Span # 1 Span # where maximum occurs Span # 1 Maximum Deflection Max Downward Transient Defledtion 0.023 in Ratio= 4111 >=360 Max Upward Transient Deflection -0.011 in Ratio= 8486 ­360 Max Downward Total Deflection 0.058 in Ratio= 1664 >=240. Max Upward Total Deflection 0.000 in Ratio 0 <240.0 Overall Maximum Deflections Load Combination Span Max . ..... Defi Location in Span Load Combination Max."+" Defl Location in Span +D+0.750L+0.75OS-0.5250E 1 0.0577 4.292 0.0000 0.000 Vertical Reactions Support notation : Far left is #1 Values in KIPS JIM Load Combination Support I Support 2 Overall MAXimum 3.126 3.156 Overall MINimum -0.043 -0.024 D Only 1.314 1.347 00 +D+L 1.474 1.507 ffin No Wood Beam Description (1-20) overturn Vertical Reactions Load Combination +D+S +D+0.750L+0.750S +D+0.60W +D-0.60W +D+0.70E +D-0.70E +D+0.750L+0.750S+0.45OW +D+0.750L+0.75OS-0.45OW +D+0.750L+0.750S+0.5250E +D+0.750L+0.75OS-0.5250E +0.60D+0.60W +0.60D-0.60W +0.60D+0.70E +0.60D-0.70E L Only 8 Only W Only -W E Only E Only * -1.0 File= S:Uobsks18As18M91811020 - 917 Pine Streetk.wo 1812031181203 1 F-enercalc trib_0811026:eo ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.17.2.2f Support notation : Far left is #1 Values in KIPS Support I Support 2 2.738 2.767 2.502 2.532 1.559 1.102 1.069 1.592 2.146 0.515 0,482 2.179 2.686 2.349 2.319 2.716 3.126 1.909 1.878 3.156 1.033 0.563 0.544 1.053 1.620 -0.024 -0.043 1.640 0.160 0.160 1,424 1.421 0.408 -0.408 -0.408 0.408 1.188 -1-188 -1.188 1-188 Nq Am File= SAJobs\s18�s1811\s1811020 -917 Pine Street\wo 181203\181203 1F-enerealc trib-s'1811020ed Nood Beam ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.17.2.2E -ic. #: KW-06006655 Licensee: SOUND STRUCTURAL SOLUTION Description : (1-20) overstrength CODE REFERENCES Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10 Load Combination Set: IBC 2015 Material Properties Analysis Method: Allowable Stress Design Fb - Tension Load Combination IBC 2015 Fb - Compr Fc - PrIl Wood Species Trus Joist Fc - Perp Wood Grade TimberStrand LSL 1.55E Fv Ft Beam Bracing Beam is Fully Braced against lateral -torsional buckling 2,325.0 psi 2,325.0 psi 2,170.0 psi 900.0 psi 310.0 psi 1,070.0 psi D(O. ". 35) 0(0.683) S(I.138) �V(0.512) E(l.491) D(V) D(O.683) S(I.138) .512) .668) D(0.01JL(O.04) 1.75x14 Span = 8.0 ft 0" aw PW VMW 0" ins ON E: Modulus of Elasticity Ebend-xx 1,550.0 ksi No Eminbend - xx 787.82ksi PU Density 44.990 pcf wo Applied Loads Service loads entered. Load Factors will be applied for calculations. Uniform Load : D = 0.0150, L = 0.040, Tributary Width = 1.0 ft, (FLOOR) Point Load: D = 0.6830, S = 1.138, W = 0.5120, E = 1.491 k @ 0.50 ft, (FRH) Uniform Load D = 0.010 ksf, Tributary Width = 9.0 ft, (WALL) Uniform Load D = 0.020, S = 0.0250 ksf, Extent = 6.875 ­> 8.0 ft, Tributary Width = 14.0 ft, (ROOF) Point Load : D = 0.6830, S = 1. 138, W = -0.5120, E = -2,868 k @ 6.875 ft, (FRH) Uniform Load: D = 0,020, S = 0.0250 ksf, Extent = 0.0 ­> 0.50 ft, Tributary Width = 14.0 ft, (ROOF) Maximum Bending Stress Ratio Section used for this span fb : Actual FB: Allowable Load Combination Location of maximum on span Span # where maximum occurs Maximum Deflection Max Downward Transient Deflection Max Upward Transient Deflection Max Downward Total Deflection Max Upward Total Deflection Overall Maximum Deflections Load Combination Span +D+0.750L+0.75OS-0.5250E I Vertical Reactions Load Combination Overall MAXimum Overall MINimurn D Only +D+L 0,34R. 1 Maximum Shear Stress Ratio 1.75x14 Section used for this span 1,276.80 psi fv Actual 3,667.62 psi Fv Allowable +1.1 18D-1.750E Load Combination 6.861 ft Location of maximum on span Span # 1 Span # where maximum occurs 0.028 in Ratio= 3383 >=O.O -0.028 in Ratio= 3383 >=O.O 0.067 in Ratio = 1439 >=O.O -0.004 in Ratio = 24870 >=O.O Max. "-" DO Location in Span Load Combination 0.0667 4.321 Support notation : Far left is #1 Support 1 Support 2 3.024 3.777 0.092 0.160 1.314 1.347 1.474 1.507 0.712 : 1 1.75x14 352.92 psi 496.00 psi +1.089D+0.750L+0.75OS-1.313E 8.000ft Span # 1 Max. 'Y' DO Location in Span 0.0000 0.000 Values in KIPS Wood Beam File = SAJobsW8ks18Ms1811 Description (1 -20) overstrength Vertical Reactions Support notation Far left is #1 Load Combination Support 1 Support 2 +D+S 2.738 2.767 +D+0.750L+0.750S 2.502 2.532 +D+0.60W 1.559 1.102 +D-0.60W 1.069 1.592 +D+0.70E 2.010 -0.313 +D-0.70E 0.618 3.007 +D+0.750L+0.750S+0.45OW 2.686 2.349 +D+0.750L+0.75OS-0.45OW 2.319 2.716 +D+0.750L+0.750S+0.5250E 3.024 1.287 +D+0.750L+0.75OS-0.5250E 1.980 3.777 +0.60D+0.60W 1.033 0.563 +0.60D-0,60W 0.544 1.053 +0.60D+0.70E 1.485 -0.852 +0.60D-0.70E 0.092 2.468 L Only 0.160 0.160 S Only 1.424 1.421 W Only 0.408 -0.408 -w -0.408 0.408 E Only 0.995 -2.372 E Only * -1.0 -0.995 2,372 917 Pine Streefiwo 1181120111811203 1F_enercalc trib_s1811020.ed ENERCALC, INC, 1983-2017, Build:6.17.2.28, Ver:6,17.2,' 'E Values in KIPS File= S-.Uobs1s18Xs181%1811020- 917 Pine Street4o 1812031181203 1 F—enerGalc trib_s1811020.ed Wood Beam ENERCALC, INC. 1983-2017, Build:6.17.2.28, er:6.17.2.2E Lic. # : KW-06006655 Licensee: SOUND STRUCTURAL SOLUTIONS: Description : (1 -23) overtu rn CODE REFERENCES Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10 Load Combination Set: IBC 2015 Material Properties Analysis Method: Allowable Stress Design Fb - Tension 2600 psi E: Modulus of Elasticity Load Combination IBC 2015 Fb - Compr 2600 psi Ebend-xx 2000 ksi Fc - PrIl 2510 psi Eminbend - xx 1016.535 ksi Wood Species Trus Joist Fc - Perp 750 psi Wood Grade MicroLam LVL 2.0 E Fv 285 psi Ft 1555 psi Density 42 pcf Beam Bracing Beam is Fully Braced against lateral -torsional buckling D(O.09) D(O.261) L(0.60r).Sp.'MMRSP�044) E(4.389) F D(O.01 (0.04) 3.500x14.000 Span = 6.0 ft Applied Loads Service loads entered. Load Factors will be applied for calculations. Uniform Load : D = 0.010, L = 0.040 , Tributary Width = 1.0 ft, (FLOOR) Uniform Load: D = 0.010 ksf, Extent = 0.0 ­> 5.0 ft, Tributary Width = 9.0 ft, (WALL) Point Load: D = 0.2610, L = 0.6170, S = 0.3490, W = 2.044, E = 4.389 k @ 5.0 ft, ((2-10)) Point Load : D = 1.594, L = 2.656 k @ 5.0 ft, ((2-14)) DESIGN SUMMARY I � _. �� Maximum Bending Stress Ratio 0.194.1 Maximum Shear Stress Ratio 0.506:1 Section used for this span 3.500x14.000 Section used for this span 3.500x14.000 fb : Actual 788.11 psi fv : Actual 230.75 psi FB: Allowable 4,069.39 psi Fv: Allowable 456.00 psi Load Combination +1.089D+0.750L+0.750S+0.8925E Load Combination +1.089D+0.750L+0.750S+0.8925E Location of maximum on span 4.993ft Location of maximum on span 6.000 ft Span # where maximum occurs Span # 1 Span # where maximum occurs Span # 1 Maximum Deflection Max Downward Transient Deflecf ion 0.011 in Ratio 6831 >=360 Max Upward Transient Deflection -0.011 in Ratio= 6831 >=360 Max Downward Total Deflection 0.019 in Ratio = 3842 >=240. Max Upward Total Deflection -0.004 in Ratio = 19434 >=240. Overall Maximum Deflections Load Combination Span Max . ..... Dell Location in Span Load Combination Max. 'Y' Defi Location in Span +D+0.750L+0.750S+0.5250E 1 H187 3.372 0.0000 0.000 Vertical Reactions Su pport notation : Far left is #1 Values in KIPS Load Combination Support I Support 2 Overall MAXimum 1.528 6.037 Overall MINimum 0.058 0.036 D Only 0.602 1.763 +D+L 1.267 4.611 +D+S 0.660 2.054 +D+0.750L+0.750S 1.144 4.117 Wood Beam File= SAJobsalMMM18111020 - 917 Pine Streetkwo 11811201811203 1F_enercalc trlbLs1811020,e(:( ENERCALC, INC. 1983-2017, Build:6.17.2.28, Ver:6.17.2.2E Description : (1 -23) overturn VerfiGal Reactions Support notation Far left is #1 Values in KIPS Load Combination Support I Support 2 +D+0.60W 0.806 2.785 +D-0.60W 0.397 0,741 +D+0.70E 1.114 4.324 +D-0.70E 0.090 -0.797 +D+0.750L+0.750S+0.45OW 1.298 4.884 +D+0.750L+0.75OS-OA50W 0.991 3.351 +D+0.750L+0.750S+0.5250E 1.528 6.037 +D+0.750L+0.75OS-0.5250E 0.760 2.197 two +0.60D+0.60W 0.565 2.080 +0.60D-0.60W 0.157 0.036 +0.60D+0.70E 0.873 3.618 +0.60D-0.70E -0.151 -1.502 iiwo L Only 0.666 2.848 S Only 0.058 0.291 W Only 0.341 1.703 !1M -w -0.341 -1,703 I E Only 0.732 3.658 IMw E Only * -1 -0 -0.732 -3.658 ! on "M PM I rai NC 1W m PE aw FOUNDATION ANALYSIS 6628 212th Street SW, Suite 205 - Lynnwood, WA 98036 - Ph: 425-778-1023 - Fax: 206-260-7490 w WI.W ; ON I pm "w Pm tow P" mw FTG - FOOTING, TYPICAL Soil Bearing Capacity 2000 Psf FOOTING SCHEDULE CENTER UNDER CONCENTRATED LOAD U.N.O. ID FOOTING SIZE REINFORCEMENT WIDTH (Transverse) LENGTH (Longitude) THICKNESS LONGITUDE TRANSVERSE F2 21-011 21-011 10.1 (3) #4's (3) #4's F2.5 2'-6" 21-611 10" (3) #4's (3) #4's F3 31-011 T-0" 10" (4) #4's (4) #4's F4 41-011 41-0" 12" (4) #5's (4) #5's TotallLoad 8,000 12,499 17,999 v 31,998" FWS - FOUNDATION WALL STEM Dead Live Snow Deck 20 60 25 Floor 15 40 Fnd 100 Roof 20 25 Wall 10 Bearing Capacity 2000 (0-2) (0-4) 7 T :%vq m. tv-rk F'.4 Trw Tributary Dimension Type of Load Dead Load Live Load Snow Load Total Load 15 Deck 300 900 375 1575 6 Roof 120 0 150 270 Floor 120 320 0 440 Wall 220 0 0 220 Fnd 800 0 0 800 Total 1560 1220 525 3305 Minimum Ftg Width USE (in) Stress 1.6525 24 83% Tributary Type of Load Dimension Dead Load Live Load Snow Load Total Load 11 Deck 220 660 275 1155 Roof 0 0 0 0 10 Floor 150 400 0 550 45 Wall 450 0 0 450 Fnd 600 0 0 600 Total 1420 1060 275 2755 Minimum Ftg Width USE (in) Stress 1.3775 18 92% L.w� N" FWS - FOUNDATION WALL STEM Dead Live Snow Deck 20 60 25 Floor 15 40 Fnd 1 100 Roof 20 1 25 Wall 10 Bearing Capacity 2000 (0-5) Tributary Dimension Type of Load Dead Load Live Load Snow Load Total Load Deck 0 0 0 0 14 Roof 280 0 350 630 12 Floor 180 480 0 660 22 Wall 220 0 0 220 4 Fnd 400 0 0 400 Total 1080 480 1 350 1910 Minimum Ftg Width USE (in) St 0.955 16 Pa RFA - REINFORCED FOUNDATION AT ANCHOR Anchor Tension NOTE: SEE THE FOUNDATION DErAILS FOR THE BALANCE OF FOUNDATION DETAIL Wind Seismic 1 3394 1 8523 Ilbs Material Prop rties Steel 60000 psi Conc Wall 2500 psi Conc Ftg 2500 psi PXVINS Me INSTAUM11 Wall Reinforcemnt Parameters 4 n Number ELEVATION PLAN VIEW OF crossing VIEW HAIRPIN INSTALL #4 Bar Size RFA� REINFORCED FOUNDAT19N AT ANCHOR 0.5 in Bar Diameter L—i N.T.S. RFAA in Bar Area Design Stress Ratios 9.4% Wind Stress Ratio 23.7% Seismic Stress Ratio Chapter 17 section 17.4.2.9 states that, "the design strength of the anchor reinforcement shall be permitted to be used instead of the concrete breakout strength" Cross section capacity subject to shear 0 0.75 Shear reduction factor VC 0 lb Nominal Shear Capacity provided by Concrete V, 48000 lb Nominal Shear Capacity provided by Steel (DVn 36000 lb pill tow tow ow V.d RetainPro (c) 1987-2017, Build 11.17.07.27 License : KW-06057724 Cantilevered Retaining Wall Code: IBC 20115ACI 318-14,ACI 530-13 License To: SOUND STRUCTURAL SOLUTIONS, INC FCriteria I Soil Data T� Retained Height 11,00 ft Allow Soil Bearing 2,666.0 psf Wall height above soil 0.00 ft Equivalent Fluid Pressure Method Active Heel Pressure 45.0 psf/ft Slope Behind Wall 0.00 Height of Soil over Toe 12.00 in Water height over heel = 0.0 ft Surcharge Loads Surcharge Over Heel 0.0 psf Used To Resist Sliding & Overturning Surcharge Over Toe 0.0 psf Used for Sliding & Overturning [�Axial Load Applied to St��i Axial Dead Load 0.0 lbs Axial Live Load 0.0 lbs Axial Load Eccentricity 0.0 in Earth Pressure Seismic L-o-a-d--- Method : Uniform Multiplier Used 7.000 (Multiplier used on soil density) Design Summary Wall Stability Ratios Overturning 1.42 Ratio < Sliding 1.26 Ratio < Total Bearing Load 5,131 lbs ... resultant ecc. 28.29 in Soil Pressure @ Toe 2,318 psf OK Soil Pressure @ Heel 0 psf OK Allowable 2,666 psf Soil Pressure Less Than Allowable ACI Factored @ Toe 3,245 psf ACI Factored @ Heel 0 psf Footing Shear @ Toe 44.3 psi OK Footing Shear @ Heel 13.5 psi OK Allowable 75.0 psi Sliding CaIcs Lateral Sliding Force 4,056.0 lbs less 100% Passive Force = 2,816.7 lbs less 100% Friction Force = 2,308.8 lbs Added Force Req'd 0.0 lbs OK .... for 1.5 Stability 958.5 lbs NG Vertical component of active lateral soil pressure IS considered in the calculation of soil bearing pressures. Load Factors - Building Code Dead Load Live Load Earth, H Wind, W Seismic, E IBC 2015,ACI 1.200 1.600 1.600 1.000 1.000 Passive Pressure 300.0 psf/ft Soil Density, Heel = 110.00 pef Soil Density, Toe = 110.00 Pcf FootingIlSoil Friction 0.450 Soil height to ignore for passive pressure 0.00 in d Applied to Stem--i Lateral Load 0.0 #/ft ... Height to Top 0.00 ft ... Height to Bottom 0.00 ft Load Type = Wind (W) (Service Level) Wind on Exposed Stem = 0.0 psf (Service Level) Uniform Seismic Force = 85.167 Total Seismic Force = 1,036.194 Adjacent Footing Load Ji Adjacent Footing Load 0.0 lbs Footing Width 0.00 ft Eccentricity 0.00 in Wall to Ftg CL Dist 0.00 ft Footing Type Line Load Base Above/Below Soil at Back of Wall 0.0 ft Poisson's Ratio 0.300 Stem Construction A 3rd Stem OK Design Height Above Ftg ft = 2.33 51. Wall Material Above "Ht" = Concrete 5! Design Method LRFD Thickness 10.00 Rebar Size # 5 Rebar Spacing 8.00 Rebar Placed at 7.687 Design Data fb/FB + fa/Fa 0.738 Total Force @ Section Service Level lbs = Strength Level lbs = 3,444.5 Moment .... Actual Service Level ft-# = Strength Level ft-# = 11,021.5 Moment ..... Allowable ft-# = 14,936.9 Shear ..... Actual Service Level psi = Strength Level psi = 37.3 Shear ..... Allowable psi = 75.0 Anet (Masonry) in2 = Rebar Depth 'd' in= 7.69 Masonry Data fm psi = Fs psi = Solid Grouting Modular Ratio'n' Wall Weight Psf 125.0 Short Term Factor Equiv. Solid Thick. Masonry Block Type = Medium Masonry Design Method = ASD Concrete Data fc psi = 2,500.0 Fy psi = 60,000.0 2nd Bottom Stem OK Stem OK 2.33 0.00 Concrete Concrete LRFD LRFD 10.00 10.00 # 5 # 5 4.00 4.00 7.687 Edge 0.400 0.766 3,444.5 5,292.8 11,021.5 21,124.6 27,577.5 27,577.5 37.3 57.4 75.0 75.0 7.69 7.69 125.0 leight 125.0 2,500.0 2,500.0 60,000.0 60,000.0 RetainPro (c) 1987-2017, Build 11.17.07.27 License: KW-06057724 Cantilevered Retaining Wall Code: IBC 2015ACI 318-14,ACI 530-13 License To: SOUND STRUCTURAL SOLUTIONS, INC Concrete Stem Rebar Area Details 3rd Stem Vertical Reinforcing As (based on applied moment): 0.3324 in2/ft (4/3) * As : 0.4432 in2/ft 200bd/fy: 200(12)(7.687)/60000 0.3075 in2/ft 0.0012bh : 0.0012(12)(10): 0.144 in2/ft Required Area 0.3324 in2/ft Provided Area 0.465 in2/ft Maximum Area: 1.0413 in2/ft 2nd Stem Vertical Reinforcing As (based on applied moment): 0.3324 in2/ft (4/3) * As: 0.4432 in2/ft 200bd/fy: 200(12)(7,687)/60000: 0.3075 in2/ft 0.0012bh : 0.0012(12)(10): 0.144 in2/ft Required Area 0.3324 in2/ft Provided Area 0.93 in2/ft Maximum Area: 1.0413 in2/ft a" am 00 Horizontal Reinforcing an ftm Min Stem T&S Reinf Area 2.081 in2 Min Stem T&S Reinf Area per ft of stem Height: 0.240 in2/ft Horizontal Reinforcing Options : One layer of : Two layers of #4@ 10.00 in #4@ 20.00 in #5@ 15.50 in #5@ 31.00 in #6@ 22.00 in #6@ 44.00 in Horizontal Reinforcing Min Stem T&S Reinf Area 0.000 in2 Min Stem T&S Reinf Area per ft of stem Height: 0.000 in2/ft Horizontal Reinforcing Options : One layer of Two layers of #4@ 0.00 in #4@ 0.00 in #5@ 0.00 in #5@ 0.00 in #6@ 0.00 in #6@ 0.00 in Bottom Stem Vertical Reinforcing Horizontal Reinforcing As (based on applied moment): 0.6371 in2/ft (4/3) * As: 0.8495 in2/ft Min Stem T&S Reinf Area 0.559 in2 200bd/fy: 200(12)(7.687)/60000 0.3075 in2/ft Min Stem T&S Reinf Area per ft of stem Height: 0.240 in2/ft 0.0012bh : 0.0012(12)(10): 0.144 in2/ft Horizontal Reinforcing Options: One layer of : Two layers of Required Area 0.6371 in2/ft #4@ 10.00 in #4@ 20.00 in Provided Area 0.93 in2/ft #5@ 15.50 in #5@ 31.00 in Maximum Area: 1.0413 in2/ft #6@ 22.00 in #6@ 44.00 in Footing Dimensions & Stre Footing Design Res Toe Width 5.67 ft Toe Heel Heel Width 2.00 Factored Pressure 3,245 0 psf Total Footing Width 7.67 Mu': Upward 30,099 0 ft_# Footing Thickness 14.00 in Mu': Downward 5,490 1, 131 ft-# Mu: Design 24,609 1, 131 ft-# Key Width 14-00 in Actual 1 -Way Shear = 44.31 13.47 psi Key Depth 26.00 in Allow 1 -Way Shear = 75.00 40.00 psi Key Distance from Toe 0.00 ft Toe Reinforcing = # 5 @ 4.00 in fo = 2,500 psi Fy 60,000 psi Heel Reinforcing = None Spec'd Footing Concrete Density 150.00 pcf Key Reinforcing = # 5 @ 8.00 in Min. As % 0b.0018 Other Acceptable Sizes & Spacings Cover @ Top 2.00 @ Btm.= 3.50 in Toe: #4@ 4.25 in, #5@ 6.59 in, #6@ 9.35 in, #7@ 12.75 in, #8@ 16.78 in, #9@ 21.2 Heel: Not req'd: Mu < phi*5*lambda*sqrt(fc)*Sm Key: #4@ 7.94 in, #5@ 12.30 in, #6@ 17.46 in, #7@ 23.81 in, Min footing T&S reinf Area 2.58 in2 Min footing T&S reinf Area per foot 0.34 M2 A If one layer of horizontal bars: If two layers of horizontal bars: #4@ 7.14 in #4@ 14.29 in #5@ 11.07 in #5@ 22.14 in #6@ 15.71 in #6@ 31.43 in W um ow No 04 %NW Pq RetainPro (c) 1987-2017, Build 11.17.07.27 License: KW-06057724 Cantilevered Retaining Wall License To: SOUND STRUCTURAL SOLUTIONS, INC Code: IBC 20115ACI 318-14,ACI 53CI-13 Summa�� of Overturninq & Resisting Forces & Moments ..... OVERTURNING ..... ..... RESISTING ..... Force Distance Moment Force Distance Moment Item lbs ft ft-# lbs ft ft-# Heel Active Pressure 3,330.6 4.06 13,507.5 Soil Over Heel 1,411.7 7.08 9,998.14 Surcharge over Heel Sloped Soil Over Heel Surcharge Over Toe Surcharge Over Heel Adjacent Footing Load Adjacent Footing Load = Added Lateral Load Axial Dead Load on Stem = Load @ Stem Above Soil Axial Live Load on Stem = Seismic Earth Load 725.3 6.08 4,412.5 Soil Over Toe 623.3 2.83 1,765.7 Surcharge Over Toe Total 4,056.0 O.T.M. 17,920.0 Stem Weight(s) 1,375.0 6.08 8,363.7 Earth @ Stem Transitions . Footing Weight 1,341,6 3.83 5,142.2 MW Resisti ng/Overturn Ing Ratio 1.42 Key Weight 379.2 0.58 221.2 Vertical Loads used for Soil Pressure 5,130.6 lbs Vert. Component 7.67 Total 5,130.6 lbs R.M.= 25,4911 If seismic is included, the OTM and sliding ratios Axial live load NOT included in total displayed, or used for overturning be 1.1 per section 1807.2.3 of IBC 2009 or IBC 201 resistance, but is included for soil pressure calculation. Vertical component of active lateral soil pressure IS considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS considered in the calculation of Overturning Resistance. Tilt I Horizontal Deflection at Too of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 250.0 pci Horizontal Defl @ Top of Wall (approximate only) 0.092 in The above calculation is not valid if the heel soil bearing pressure exceeds that of tile toe because the wall would then tend to rotate into the retained soil. RetainPro (c) 1987-2017, Build 11.17.07.27 License : KW-06057724 Cantilevered Retaining Wall Code: IBC 2015ACI 318-14ACI 530-13 License To: SOUND STRUCTURAL SOLUTIONS, INC Criteria MMM77 1.00 ft [Soil Data EN=0077,000.0 psf 90� Retained Height Allow Soil Bearing Wall height above soil 0.00 ft Equivalent Fluid Pressure Method Slope Behind Wall 0.00 Active Heel Pressure 45.0 psf/ft Height of Soil over Toe 12.00 in Water height over heel = 0.0 ft Surcharge Loads Surcharge Over Heel 0.0 psf Used To Resist Sliding & Overturning Surcharge Over Toe 0.0 psf Used for Sliding & Overturning Axial Load Applied to Sterrj::::J Axial Dead Load 0.0 lbs Axial Live Load 0.0 lbs Axial Load Eccentricity 0.0 in Design Summary Wall Stability Ratios Overturning 1 i89 OK Sliding 1.54 OK Total Bearing Load 5,131 lbs ...resultant ecc. 17 97 in Soil Pressure @ Toe 1,464 psf OK Soil Pressure @ Heel 0 psf OK Allowable 2,000 psf Soil Pressure Less Than Allowable ACI Factored @ Toe 2,G50 psf ACI Factored @ Heel 0 psf Footing Shear @ Toe 38.5 psi OK Footing Shear @ Heel 13.2 psi OK Allowable 75.0 psi Sliding CaIcs Lateral Sliding Force 3,330.6 lbs less 100% Passive Force 2,816.7 lbs less 100% Friction Force 2,308.8 lbs Added Force Req'd 0.0 lbs OK .... for 1.5 Stability 0.0 lbs OK Vertical component of active lateral soil pressure IS considered in the calculation of soil bearing pressures. Load Factors - Building Code Dead Load Live Load Earth, H Wind, W Seismic, E IBC 20-15,ACI 1.200 1.600 1.600 1.000 1.000 Passive Pressure 300.0 psf/ft Soil Density, Heel = 110.00 pcf Soil Density, Toe = 110.00 Pcf Footingl[Soil Friction 0.450 Soil height to ignore for passive pressure 0.00 in Lateral Load Applied to Stem Lateral Load 0.0 #/ft ... Height to Top 0.00 ft ... Height to Bottom 0.00 it Load Type = Wind (W) (Service Level) Wind on Exposed Stem = 0.0 Psf (Service Level) Adjacent Footing Load djacent oo ing Load 0.0 lbs Footing Width 0.00 ft Eccentricity 0.00 in Wall to Ftg CL Dist 0.00 ft Footing Type Line Load Base Above/Below Soil at Back of Wall 0.0 ft Poisson's Ratio 0.300 F-Stem Constr� 3rd Stem OK Design Height Above Ftg ft = 2.33 Wall Material Above "Ht" = Concrete Design Method LRFD Thickness 10.00 Reber Size # 5 Reber Spacing 8.00 Rebar Placed at 7.687 Design Data fb/FB + fa/Fa 0.524 Total Force @ Section Service Level lbs = Strength Level lbs = 2,706.1 Moment .... Actual Service Level ft-# = Strength Level ft-# = 7,820.6 Moment ..... Allowable ft-# = 14,936.9 Shear ..... Actual Service Level psi = Strength Level psi = 29.3 Shear ..... Allowable psi = 75.0 Anet (Masonry) in2 = Reber Depth 'd' in = 7.69 Masonry Data fm psi = Fs psi = Solid Grouting Modular Ratio'n' Wall Weight PSI` 125.0 Short Term Factor Equiv. Solid Thick. Masonry Block Type = Medium V Masonry Design Method = ASID Concrete Data fc psi = 2,500.0 Fy psi = 60,000.0 2nd Bottom Stem OK Stem OK 2 . 33 0 . 00 Concrete Concrete LRFD LRFD 10.00 10.00 # 5 # 5 4.00 4.00 7,687 Edge 0.284 0.579 2,706.1 4,356.0 7,820.6 15,972.0 27,577.5 27,577.5 29.3 47.2 75.0 75.0 7.69 7.69 125.0 eight 125.0 2,500.0 2,500.0 60,000.0 60,000.0 Flo ow "W 0M as PM No 0M I" M how r 60 0 0 W" i on RetainPro (c) 1987-2017, Build 11.17.07.27 License : KW-06057724 Cantilevered Retaining Wall Code: IBC 20115ACI 318-14,ACI 530-13 License To: SOUND STRUCTURAL SOLUTIONS, INC Concrete Stem Rebar Area Details 3rd Stem Vertical Reinforcing Horizontal Reinforcing As (based on applied moment): 0.2359 in2/ft (4/3) * As : 0.3145 in2/ft Min Stem T&S Reinf Area 2.081 ir[2 200bd/fy: 200(12)(7,687)/60000: 0.3075 in2/ft Min Stem T&S Reinf Area per ft of -stem Height: 0.240 in2/ft 0.0012bh : 0,0012(12)(10): 0.144 in2/ft Horizontal Reinforcing Options: One layer of : Two layers of Required Area 0.3075 in2/ft #4@ 10.00 in #4@ 20.00 in Provided Area 0.465 in2/ft #5@ 15.50 in #5@ 31.00 in Maximum Area: 1.0413 in2/ft #6@ 22.00 in #6@ 44.00 in 2nd Stem Vertical Reinforcing Horizontal Reinforcing As (based on applied moment): 0.2359 in2/ft (4/3) * As : 0.3145 in2/ft Min Stem T&S Reinf Area 0.000 in-2 200bd/fy: 200(12)(7.687)/60000 0.3075 in2/ft Min Stem T&S Reinf Area per ft of stem Height: 0.000 in2/ft 0.0012bh: 0.0012(12)(10): 0.144 in2/ft Horizontal Reinforcing Options : One layer of Two layers of: Required Area 0.3075 in2/ft #4@ 0.00 in #4@ 0.00 in Provided Area 0.93 in2/ft #5@ 0.00 in #5@ 0.00 in Maximum Area: 1.0413 in2/ft #6@ 0.00 in #6@ 0.00 in Bottom Stem Vertical Reinforcing Horizontal Reinforcing As (based on applied moment): 0.4817 in2/ft (4/3) * As : 0.6423 in2/ft Min Stem T&S Reinf Area 0.559 in2 200bd/fy: 200(12)(7.687)/60000 0.3075 in2/ft Min Stem T&S Reinf Area per ft of stem Height: 0.240 in2/ft 0.0012bh : 0.0012(12)(10): 0.144 in2/ft Horizontal Reinforcing Options: One layer of : Two layers of: Required Area 0.4817 in2/ft #4@ 10.00 in #4@ 20.00 in Provided Area 0.93 in2/ft #5@ 15.50 in #5@ 31.00 in Maximum Area: 1.0413 in2/ft #6@ 22.00 in #6@ 44.00 in Footing Dimensions & St �engths Footing Design Result Toe Width 5.67 ft Toe Heel Heel Width 2.00 Factored Pressure 2,050 0 psf Total Footing Width 7.67 Mu': Upward 24,039 6 ft-# Footing Thickness 14.00 in Mu': Downward 5,490 1, 131 ft-# Mu: Design 18,549 1, 125 ft-# Key Width Key Depth 14.00 in Actual 1 -Way Shear = 38.55 13.20 psi 26.00 in Key Distance from Toe Allow 1 -Way Shear = 75.00 40.00 psi 0.00 ft Toe Reinforcing = # 5 @ 4.00 in fc = 2,500 psi Fy 60,000 psi Heel Reinforcing = None Spec'd Footing Concrete Density 150.00pcf Key Reinforcing = # 5 @ 8.00 in Min. As % 0.0018 Other Acceptable Sizes & Spacings Cover @ Top 2.00 @ Btm.= 3.50 in Toe: #4@ 5.64 in, #5@ 8.74 in, #6@ 12.40 in, #7g 16.91 in, #8@ 22.27 in, #9@ 28. Heel: Not req'd: Mu < phi*5*lambda*sqrt(fc)*Sm Key: #4@ 7.94 in, #5@ 12.30 in, #6@ 17.46 in, #7@ 23.81 in, Min footing T&S reinf Area 2.58 in2 Min footing T&S reinf Area per foot 0.34 in2 ift If one layer of horizontal bars: If two layers of -horizontal bars: #4@ 7.14 in #4@ 14.29 in #5@ 11.07 in #5@ 22.14 in #6@ 15.71 in #6@ 31.43 in RetainPro (c) 1987-2017, Build 11.17.07.27 License: KW-06057724 Cantilevered Retaining Wall Code: IBC 2015ACI 318-14,ACI 530-13 License To: SOUND STRUCTURAL SOLUTIONS, INC Summary of Overturning & Resisting F rces & Moments ..... OVERTURNING- .... RESISTING ..... Force Distance Force Distance Moment Item lbs ft ft-# lbs ft ft-# Heel Active Pressure 3,330.6 4.06 13,50.7.5 Surcharge over Heel Surcharge Over Toe Adjacent Footing Load Added Lateral Load Load @ Stem Above Soil Total 3,330.6 O.T.M. 13,507.5 Resisting/Overturning Ratio 1.89 Vertical Loads used for Soil Pressure 5,130.6 lbs Soil Over Heel 1,411.7 Lud 9,998.4 Sloped Soil Over Heel Surcharge Over Heel Adjacent Footing Load = Axial Dead Load on Stem = Axial Live Load on Stem = Soil Over Toe 623.3 2.83 1,765.7 Surcharge Over Toe Stem Weight(s) 1,375.0 6.08 8,363.7 Earth @ Stem Transitions Footing Weight 1,341.6 3.83 5,142.2 Key Weight 379.2 0.58 221.2 Vert. Component 7.67 Total 5,130.6 lbs R.M.= 25,491.1 Axial live load NOT included in total displayed, or u�ed for overturning resistance, but is included for soil pressure calculation. Vertical component of active lateral soil pressure IS considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS considered in the calculation of Overturning Resistance. Tilt Horizontal Deflection at Tor) of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 250.0 pci Horizontal Defl @ Top of Wall (approximate only) 0.058 in The above calculation is not valid if the heel soil bearing p �,surp g�Lcteds that of the toe because the wall would then tend to rotate into the retained soil, r, �iw L t 5 . RetainPro(c)1987-2017, Build 11.17.07.27 License: KW-06057724 Cantilevered Retaining Wall Code: IBC 2015ACI 318-14,ACI 530-13 License To: SOUND STRUCTURAL SOLUTIONS, INC Criteria ----A [-Soil Data Retained Height 10.00 ft Allow Soil Bearing 2,666.0 psf Wall height above soil 0.00 ft Equivalent Fluid Pressure Method Active Heel Pressure 45.0 psf/ft Slope Behind Wall 0.00 Height of Soil over Toe 12.00 in Water height over heel 0.0 ft Passive Pressure 300.0 psf/ft Surcharge Loads Surcharge Over Heel 0.0 psf Used To Resist Sliding & Overturning Surcharge Over Toe 0.0 Psf Used for Sliding & Overturning [ALXi�a�l Load Applied to St Axial Dead Load 0.0 lbs Axial Live Load 0.0 lbs Axial Load Eccentricity 0.0 in Earth Pressure Seismic Load Method : Uniform Multiplier Used 7.000 (Multiplier used on soil density) Design Summary Wall Stability Ratios Overturning 1.40 Ratio < Sliding 1.24 Ratio < Total Bearing Load 4,505 lbs ... resultant ecc. 25.18 in Soil Pressure @ Toe 2,433 psf OK Soil Pressure @ Heel 0 psf OK Allowable 2,666 psf Soil Pressure Less Than Allowable ACI Factored @ Toe 3,406 psf ACI Factored @ Heel 0 psf Footing Shear @ Toe 40.2 psi OK Footing Shear @ Heel 12.4 psi OK Allowable 75.0 psi Sliding Caics Lateral Sliding Force 3,416.6 lbs less 100% Passive Force = 2,204.2 lbs less 100% Friction Force = 2,027.2 lbs Added Force Req'd 0,0 lbs OK .... for 1.5 Stability 893.6 lbs NG Soil Density, Heel = 110.00 pcf Soil Density, Toe = 110.00 pcf FootingIlSoil Friction 0.450 Soil height to ignore for passive pressure 0.00 in Lateral Load Applied to Stem Lateral Load 0.0 #/ft ... Height to Top 0.00 ft ... Height to Bottom 0.00 ft Load Type = Wind (W) (Service Level) Wind on Exposed Stem = 0.0 psf (Service Level) Uniform Seismic Force = 78.167 Total Seismic Force = 872.861 Stem Construction 11- Design Height Above Ftg ft Wall Material Above "Ht" Thickness Rebar Size Rebar Spacing Rebar Placed at Design Data fb/FB + fa/Fa Total Force @ Section Service Level lbs = Strength Level lbs = Moment .... Actual Service Level ft-# = Strength Level ft-# = Moment ..... Allowable ft-# = Shear ..... Actual Service Level psi = Strength Level psi = Shear ..... Allowable psi = Anet (Masonry) in2 = Rebar Depth 'd' in= Masonry Data fm psi = Fs psi = Solid Groutino Vertical component of active lateral soil pressure IS Modular Ratio'n' considered in the calculation of soil bearing pressures. %A/ I[ XA1 ; � Load Factors - MR Building Code Dead Load 6-0 Live Load Earth, H Wind, W Seismic, E IBC 2015,ACI 1.200 1.600 1.600 1.000 1.000 a eg L PS1 Short Term Factor 3rd Adjacent Footing Load Adjacen Footing Load 0.0 lbs Footing Width 0.00 ft Eccentricity 0.00 in Wall to Ftg CL Dist 0.00 ft Footing Type Line Load Base Above/Below Soil at Back of Wall 0.0 ft Poisson's Ratio 0.300 2nd Bottom Stem OK Stem OK Stem OK 2.33 2 . 33 0 . 00 Concrete Concrete Concrete LRFD LRFD LRFD 10.00 10.00 10.00 # 5 # 5 # 5 12.00 6.00 6.00 7.687 7.687 Edge 0.755 0.398 0.820 2,717.4 2,717.4 4,381.7 7,713.8 7,713.8 15,908.3 10,213.1 19,405.6 19,405.6 29.5 29,5 47.5 75.0 75.0 75.0 7.69 7.69 7.69 125.0 125.0 125.0 Equiv. Solid I HICK. Masonry Block Type = Medium Weight Masonry Design Method = ASD Concrete Data fc psi = Fy psi = 2,500.0 2,500.0 2,500.0 60,000.0 60,000.0 60,000.0 RetainPro (c) 1987-2017, Build 11.17.07.27 License: KW-06057724 Cantilevered Retaining Wall License To: SOUND STRUCTURAL SOLUTIONS, INC Concrete Stem Rebar Area Details 3rd Stem Vertical Reinforcing As (based on applied moment): 0.2326 in2/ft (4/3) * As : 0.3102 in2/ft 200bd/fy: 200(12)(7.687)/60000 0.3075 in2/ft 0.0012bh : 0.0012(12)(10): 0.144 in2/ft Required Area 0.3075 in2/ft Provided Area 0.31 in2/ft Maximum Area: 1.0413 in2/ft 2nd Stem Vertical Reinforcing As (based on applied moment): 0.2326 in2/ft (4/3) * As : 0.3102 in2/ft 200bd/fy: 200(12)(7.687)/60000 0.3075 in2/ft 0.0012bh : 0.0012(12)(10): 0.144 in2/ft Required Area 0.3075 in2/ft Provided Area 0.62 in2/ft Maximum Area: 1.0413 in2/ft Horizontal Reinforcing P" No 004 Code: IBC 20115ACI 318-14,ACI 530-13 PW Min Stem T&S Reinf Area 1.841 in2 Min Stem T&S Reinf Area per ft of stem Height: 0.240 in2/ft Horizontal Reinforcing Options: One layer of : Two layers of #4@ 10.00 in #4@ 20.00 in #5@ 15.50 in #5@ 31.00 in #6@ 22.00 in #6@ 44.00 in Horizontal Reinforcing Min Stem T&S Reinf Area 0.000 in2 Min Stem T&S Reinf Area per ft of stem Height: 0.000 in2/ft Horizontal Reinforcing Options : One layer of Two layers of #4@ 0.00 in #4@ 0.00 in #5@ 0.00 in #5@ 0.00 in #6@ 0.00 in #6@ 0.00 in Bottom Stem Vertical Reinforcing Horizontal Reinforcing As (based on applied moment): 0.4798 in2/ft (4/3) * As : 0.6397 in2/ft Min Stem T&S Reinf Area 0.559 in2 200bd/fy: 200(12)(7.687)/60000 0.3075 in2/ft Min Stem T&S Reinf Area per ft of stem Height: 0.240 in2/ft 0.0012bh : 0.0012(12)(10): 0.144 in2/ft Horizontal Reinforcing Options: One layer of : Two layers of Required Area 0.4798 in2/ft #4@ 10.00 in #4@ 20.00 in Provided Area 0.62 in2/ft #5@ 15.50 in #5@ 31.00 in Maximum Area: 1.0413 in2/ft #6@ 22.00 in #6@ 44.00 in Footing Dimensions & Strengths Footing Design Results Toe Width 4.67 ft Toe Heel Heel Width 2.00 Factored Pressure 3,406 0 psf Total Footing Width 6.67 Mu': Upward 21,642 0 ft-# Footing Thickness 14.00 in Mu': Downward 3,723 1,041 ft-# Mu: Design 17,920 1,041 ft-# Key Width 14.00 in Actual 1-Way Shear = 40.23 12.40 psi Key Depth 20.00 in Allow 1 -Way Shear = 75.00 40.00 psi Key Distance from Toe 0.00 ft Toe Reinforcing = # 5 @ 6.00 in fc = 2,500 psi Fy 60�000 psi Heel Reinforcing = None Spec'd Footing Concrete Density 150.00pcf Key Reinforcing = None Spec'd Min. As % 0.0018 Other Acceptable Sizes & Spacings Cover @ Top 2.00 @ Btm.=: 3.50 in Toe: #4@ 5.83 in, #5@ 9.04 in, #6@ 12.84 in, #7@ 17.50 in, #8@ 23.05 in, #9@ 29. Heel: Not req'd: Mu < phi*5*lambda*sqrt(fc)*Sm Key: Not req'd: Mu < phi*5*lambda*sqrt(fc)*Sm Min footing T&S reinf Area 2.24 in2 Min footing T&S reinf Area per foot 0.34 in2 A If one layer of horizontal bars: If two layers of horizontal bars: #4@ 7.14 in #4@ 14.29 in #5@ 11.07 in #5@ 22.14 in #6@ 15.71 in #6@ 31.43 in oft bw JIM No 00 low to on ow WWI IL= ON RetainPro (c) 1987-2017, Build 11.17.07.27 License: KW-06057724 Cantilevered Retaining Wall License To: SOUND STRUCTURAL SOLUTIONS, INC Code: IBC 2015ACI 318-14,ACI 530-13 Summary of Overturning & Resisting Forces & Moments ..... OVERTURNING ... '6ment ..... RESISTING.. Force, Distance Force Distance- Moment 6wi Item lbs ft ft-# lbs ft ft-# Heel Active Pressure 2,805.6 3.72 10,443.2 Soil Over Heel 1,283.3 6.08 7,806.1 Surcharge over Heel Sloped Soil Over Heel Surcharge Over Toe Surcharge Over Heel Adjacent Footing Load Adjacent Footing Load = Added Lateral Load Axial Dead Load on Stem = Load @ Stem Above Soil Axial Live Load on Stem = Seismic Earth Load 611.0 5.58 3,411.4 Soil Over Toe 513.3 2.33 1,197A Surcharge Over Toe Total 3,416.6 O.T.M. 13,854.6 Stem Weight(s) 1,250.0 5.08 6,353.3 Earth @ Stem Transitions I OW Footing Weight 1,166.6 3.33 3,888.1 Resisting/Overturning Ratio 1.40 Key Weight 291.7 0.58 170.1 Vertical Loads used for Soil Pressure 4,504.8 lbs Vert. Component 6.67 Total 4,504.8 lbs R.M.= 19,415A MINI If seismic is included, the OTM and sliding ratios Axial live load NOT included in totail displayed, or used for overturning be 1.1 per section 1807.2.3 of I BC 2009 or I BC 201 resistance, but is included for soil pressure calculation. Vertical component of active lateral soil pressure IS considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS considered in the calculation of Overturning Resistance. Tilt Horizontal Deflection at Top of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 250.0 pci Horizontal Def! @ Top of Wall (approximate only) 0.101 in The above calculation is not valid if the heel soil bearin pressure exceeds that of the toe, because thev;fall would then tend to rotate into the retained soil. FIX RetaInPro (c) 1987-2017, Build 11.17.07.27 License: KW-06057724 Cantilevered Retaining Wall Code: IBC 2015ACI 318-14,ACI 530-13 License To: SOUND STRUCTURAL SOLUTIONS, INC rcriteria [Soil Data Retained Height 10.00ft Allow Soil Bearing 2,000.0 psf Wall height above soil 0.0aft Equivalent Fluid Pressure Method Active Heel Pressure 45.0 psf1ft Slope Behind Wall 0.00 Height of Soil over Toe 12.00 in Water height over heel = O.Gft Surcharge Loads Surcharge Over Heel 0.0 psf Used To Resist Sliding & Overturning Surcharge Over Toe 0.0 psf Used for Sliding & Overturning [Axial Load Applied to Stem:::�Ill Axial Dead Load 0.0 lbs Axial Live Load 0.0 lbs Axial Load Eccentricity 0.0 in Design Summary Wall Stability Ratios Overturning 1.86 OK Sliding 1,51 OK Total Bearing Load 4,505 lbs ... resultant ecc. 16-10 in Soil Pressure @ Toe 1,508 psf OK Soil Pressure @ Heel 0 psf OK Allowable 2,000 psf Soil Pressure Less Than Allowable ACI Factored @ Toe 2,111 psf ACI Factored @ Heel 0 psf Footing Shear @ Toe 33.5 psi OK Footing Shear @ Heel 12.1 psi OK Allowable 75.0 psi Sliding CaIcs Lateral Sliding Force 2,805.6 lbs less 100% Passive Force = 2,204.2 lbs less 100% Friction Force = 2,027.2 lbs Added Force Req'd 0.0 lbs OK .... for 1.5 Stability 0.0 lbs OK Vertical component of active lateral soil pressure IS considered in the calculation of soil bearing pressures. Load Factors - Building Code Dead Load Live Load Earth, H Wind, W Seismic, E IBC 2015,ACI 1.200 1.600 1.600 1.000 1.000 Passive Pressure 300.0 psf/ft Soil Density, Heel = 110.00 pef Soil Density, Toe = 110.00 pcf FootingIlSoil Friction 0.450 Soil height to ignore for passive pressure 0.00 in F-Lateral Load Applied to Stem MM7�0.0 Lateral Load #/ft ... Height to Top 0.00 ft ... Height to Bottom 0.00 ft Load Type = Wind (W) (Service Level) Wind on Exposed Stem = 0.0 psf (Service Level) Adjacent Footing Load Adjacent Footing Load 0.0 lbs Footing Width 0.00 ft Eccentricity 0.00 in Wall to Ftg CL Dist 0.00 ft Footing Type Line Load Base Above/Below Soil at Back of Wall 0.0 ft Poisson's Ratio 0.300 �tem Constr 3rd S Stem OK Design Height Above Ftg ft = 2.33 Wall Material Above "Ht" = Concrete Design Method LRFD Thickness 10.00 Rebar Size # 5 Rebar Spacing 12.00 Rebar Placed at 7.687 Design Data fb/FB + fa/Fa 0.530 Total Force @ Section Service Level lbs = Strength Level lbs = 2,117.8 Moment .... Actual Service Level ft-# = Strength Level ft-# = 5,414.6 Moment ..... Allowable ft-# = 10,213.1 Shear ..... Actual Service Level psi = Strength Level psi = 23.0 Shear ..... Allowable psi = 75.0 Anet (Masonry) in2 = Rebar Depth 'd' in= 7.69 Masonry Data fm psi = Fs psi = Solid Grouting Modular Ratio'n' Wall Weight psf 125.0 Short Term Factor Equiv. Solid Thick. Masonry Block Type = Medium V Masonry Design Method = ASD Concrete Data fc psi = 2,500.0 Fy psi = 60,000.0 2nd Bottom Stem OK Stem OK 2.33 0.00 Concrete Concrete LRFD LRFD 10.00 10.00 # 5 # 5 6,00 6.00 7,687 Edge 0.279 0,618 2,117.8 3,600.0 5,414.6 12,000.0 19,405.6 19,405.6 23.0 39.0 75.0 75.0 7.69 7.69 125.0 eight 125.0 2,500.0 2,500.0 60,000.0 60,000.0 to no PW bw MR am 110 MW oft No too am MW on ino wo h" RetainPro(c)1987-2017, Build 11.17.07.27 License: KW-06057724 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13 License To: SOUND STRUCTURAL SOLUTIONS, INC Concrete Stem Rebar Area Details 40 I 3rd Stem Vertical Reinforcing 1 6W As (based on applied moment) 0. 1633 in2/ft (4/3) * As : 0.2177 in2/ft 200bd/fy: 200(12)(7.687)/60000 0.3075 in2/ft 0.0012bh : 0.0012(12)(10): 0.144 in2/ft Required Area 0.2177 in2/ft Provided Area 0.31 in2/ft Maximum Area: 1.0413 in2/ft 2nd Stem Vertical Reinforcing As (based on applied moment): 0.1633 in2/ft (4/3) * As : 0.2177 in2/ft 200bd/fy 200(12)(7.687)/60000: 0.3075 in2/ft 0.0012bh 0.0012(12)(10): 0.144 in2/ft Required Area 0.2177 in2/ft Provided Area 0.62 in2/ft Maximum Area: 1.0413 in2/ft Horizontal Reinforcing Min Stem T&S Reirif Area 1.841 in2 Min Stem T&S Reinf Area per ft of stem Height: 0.240 in2/ft Horizontal Reinforcing Options : One layer of : Two layers of #4@ 10.00 in #4@ 20.00 in #5@ 15.50 in #5@ 31.00 in #6@ 22.00 in #6@ 44.00 in Horizontal Reinforcing Min Stein T&S Reinf Area 0.000 in2 Min Stein T&S Reinf Area per ft of stem Height : 0.000 in2/ft Horizontal Reinforcing Options: One layer of Two layers of: #4@ 0.00 in #4@ 0.00 in #5@ 0.00 in #5@ 0.00 in #6@ 0.00 in #6@ 0.00 in Bottom Stem Vertical Reinforcing Horizontal Reinforcing As (based on applied moment): 0.3619 in2/ft (4/3) * As 0.4826 in2/ft Min Stem T&S Reinf Area 0.559 in2 200bd/fy 200(12)(7.687)/60000 0.3075 in2/ft Min Stern T&S ReinfArea per ft of stem Height: 0.240 in2/ft 0.0012bh 0.0012(12)(10): 0.144 in2/ft Horizontal Reinforcing Options : One layer of: Two layers of: Required Area 0.3619 in2/ft #4@ 10.00 in #4@ 20.00 in Provided Area 0.62 in2/ft #5@ 15.50 in #5@ 31.00 in Maximum Area: 1.0413 in2/ft #6@ 22.00 in #6@ 44.00 in Footing Dimensions & StrengthsA I Footing Design Results Toe Width 4.67 ft Toe Heel Heel Width 2.00 Factored Pressure 2,111 0 psf Total Footing Width 6.67 Mu': Upward 16,999 6 ft-# Footing Thickness 14.00 in Mu': Downward 3,723 1,041 ft-# Mu: Design 13,276 1,035 ft-# Key Width 14.00 in Actual 1 -Way Shear = 33.47 12.12 psi Key Depth 20.00 in Allow 1 -Way Shear = 75.00 40.00 psi Key Distance from Toe 0.00 ft Toe Reinforcing = # 5 @ 6.00 in fc = 2,500 psi Fy 60,000 psi Heel Reinforcing = None Spec'd Footing Concrete Density 150.00pcf Key Reinforcing = None Spec'd Min. As % 0.0018 Other Acceptable Sizes & Spacings Cover @ Top 2.00 @ Btm.= 3.50 in Toe: #4@ 6.00 in, #5@ 9.30 in, #6@ 13.20 in, #7@ 18.00 in, #8@ 23.70 in, #9@ 30. Heel: Not req'd: Mu < phi*5*lambda*sqrt(fc)*Sm Key: Not req'd: Mu < phi*5*lambda*sqrt(fc)*Sm PIN Min footing T&S reinf Area 2.24 in2 Min footing T&S reinf Area per foot 0.34 in2 /ft If one layer of horizontal bars: If two layers of horizontal bars: #4@ 7.14 in #4@ 14.29 in #5@ 11.07 in PIN #5@ 22.14 in #6@ 15.71 in I #6@ 31.43 in No pa ow RetainPro(c)1987-2017, Build 11.17.07.27 License: KW'06057724 Cantilevered Retaining Wall Code: IBC 2015ACI 318-14ACI 530-13 License To: SOUND STRUCTURAL SOLUTIONS, INC Summa of Overturninq & Resisting Forces & Moments ..... OVERTURNING ..... ..... RESISTING ..... Force Distance Moment Force Distance Moment Item lbs It ft-# lbs ft ft-# Heel Active Pressure 2,8056 3.72 10,443.2 Soil Over Heel 1,283.3 6.08 7,806.1 Surcharge over Heel Surcharge Over Toe Adjacent Footing Load Added Lateral Load Load @ Stem Above Soil Total 2,805.6 O.T.M. 10,443.2 Resist! n g/Overturning Ratio 1.86 Vertical Loads used for Soil Pressure 4,504.8 lbs Sloped Soil Over Heel Surcharge Over Heel Adjacent Footing Load = Axial Dead Load on Stem = Axial Live Load on Stem = Soil Over Toe 513.3 2.33 1,197.4 Surcharge Over Toe Stem Weight(s) 1,250.0 5.08 6,353.2 Earth @ Stem Transitions Footing Weight 1,166.6 3.33 3,888.1 Key Weight 291.7 0.58 170.1 Vert. Component 6.67 Total 4,504.8 lbs R.M.= 19,415.1 Axial live load NOT included in total displayed, or used for overturning resistance, but is included for soil pressure calculation. Vertical component of active lateral soil pressure IS considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS considered in the calculation of Overturning Resistance. Tilt Horizontal Deflection at Tor) of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 250.0 pci Horizontal Deft @ Top of Wall (approximate only) 0.063 in The above calculation is not valid if the heel soil bearing pressure exceeds that of the toe because the wall would then tend to rotate into the retained soil, tow low RetainPro(c)1987-2017, Build 11.17.07.27 License: KW-06057724 Cantilevered Retaining Wall Code: IBC 2015ACI 318-14,ACI 530-13 License To: SOUND STRUCTURAL SOLUTIONS, INC Criteria [Soil Data Retained Height 9.00 ft Allow Soil Bearing 2,666.0 psf Wall height above soil 0.00 ft Equivalent Fluid Pressure Method Active Heel Pressure 45.0 psf/ft Slope Behind Wall 0.00 Height of Soil over Toe 12.00 in Water height over heel 0.0 ft Passive Pressure 300.0 psf/ft Surcharge Loads Surcharge Over Heel 0.0 psf Used To Resist Sliding & Overturning Surcharge Over Toe 0.0 psf Used for Sliding & Overturning [Axial Load Applied to Stem Axial Dead Load 0.0 lbs Axial Live Load 0.0 lbs Axial Load Eccentricity 0.0 in Earth Pressure Seismic Load Method : Uniform Multiplier Used 7.000 (Multiplier used on soil density) Design Summary Wall Stability Ratios Overturning 1.41 Ratio < Sliding 1.27 Ratio < Total Bearing Load 3,638 lbs ... resultant ecc. 22.41 in Soil Pressure @ Toe 2,142 psf OK Soil Pressure @ Heel 0 psf OK Allowable 2,666 psf Soil Pressure Less Than Allowable ACI Factored @ Toe 2,999 psf ACI Factored @ Heel 0 psf Footing Shear @ Toe 40.1 psi OK Footing Shear @ Heel 13.3 psi OK Allowable 75.0 psi Sliding CaIcs Lateral Sliding Force 2,740.0 lbs less 100% Passive Force 1,837.5 lbs less 100% Friction Force 1,637.0 lbs Added Force Req'd 0.0 lbs OK .... for 1.5 Stability 635.5 lbs NG Soil Density, Heel = 110.00 pcf Soil Density, Toe = 110.00 pCf FootingIlSoil Friction 0.450 Soil height to ignore for passive pressure 0.00 in Lateral Load Applied to Stem Lateral Load 0.0 #/ft ... Height to Top 0.00 ft ... Height to Bottom 0.00 ft Load Type Wind (W) (Service Level) Wind on Exposed Stem 0.0 psf (Service Level) Uniform Seismic Force = 70.000 Total Seismic Force = 700.000 Stem Construction Design Height Above Ftg ft 1.5! Wall Material Above "Ht" 1.5! D-i n Method Vertical component of active lateral soil pressure IS considered in the calculation of soil bearing pressures Load Factors - Building Code Dead Load Live Load Earth, H Wind, W Seismic, E IBC 2015,ACI 1.200 1.600 1.600 1.000 1.000 ZI Thickness Rebar Size Rebar Spacing Rebar Placed at Design Data fb/FB + fa/Fa Total Force @ Section Service Level lbs = Strength Level lbs = Moment .... Actual Service Level ft-# = Strength Level ft-# = Moment ..... Allowable ft-# = Shear ..... Actual Service Level psi = Strength Level psi = Shear ..... Allowable psi = Anet (Masonry) in2 = Rebar Depth 'd' in= Masonry Data fm psi = Fs psi = Solid Grouting Modular Ratio'n' Wall Weight psf Short Term Factor 3rd Adjacent Footing Load �J Adjacent Footing Load 0.0 lbs Footing Width 0.00 ft Eccentricity 0.00 in Wall to Ftg CIL Dist 0.00 ft Footing Type Line Load Base Above/Below Soil at Back of Wall 0.0 ft Poisson's. Ratio 0.300 2nd Bottom Stem OK Stem OK Stem OK 2.33 2.33 0.00 Concrete Concrete Concrete LRFD LRFD LRFD 8.00 8.00 8.00 # 5 # 5 # 5 12.00 6.00 6.00 5.687 5.687 Edge 0.689 0.370 0.838 2,068.5 2,068.5 3,546.0 5,118,0 5,118.0 11,583.0 7,423.1 13,825.6 13,825.6 30.3 30.3 52.0 75.0 75JO 75.0 5.69 5.69 5.69 100.0 100-0 100.0 Equiv. Solid I HICK. Masonry Block Type = Medium Weight Masonry Design Method = ASD Concrete Data fc psi = Fy psi = 2,500.0 2,500.0 2,500.0 60,000.0 60,000.0 60,000.0 RetainPro (c) 1987-2017, Build 11.1 7.07.2T License: KW-06057724 Cantilevered Retaining Wall Code: 113C 2015ACI 318-14,ACI 530-13 OR License To: SOUND STRUCTURAL SOLUTIONS, INC Concrete Stem Rebar Area Details 3rd Stem Vertical Reinforcing Horizontal Reinforcing JIM As (based on applied moment): 0.2119 in2/ft (4/3) * As: 0.2825 in2/ft Min Stem T&S Reinf Area 1.281 in2 200bd/fy: 200(12)(5.687)/60000 0.2275 in2/ft Min Stem T&S Reinf Area per ft of stem Height: 0.192 in2/ft 0.0012bh : 0.0012(12)(8): 0, 1152 in2/ft Horizontal Reinforcing Options : One layer of : Two layers of Required Area 0.2275 in2/ft #4@ 12.50 in #4@ 25.00 in Provided Area 0.31 in2/ft #5@ 19 38 in #5@ 38.75 in JIM Maximum Area: 0.7704 in2/ft #6@ 27.50 in #6@ 55.00 in 2nd Stem Vertical Reinforcing Horizontal Reinforcing As (based on applied moment): 0.2119 in2/ft (4/3) * As : 0.2825 in2/ft Min Stem T&S Reinf Area 0.000 in2 200bd/fy: 200(12)(5.687)/60000 0.2275 in2/ft Min Stem T&S Reinf Area per ft of stem Height: 0.000 in2/ft 0.0012bh : 0.0012(12)(8): 0. 1152 in2/ft Horizontal Reinforcing Options : One layer of Two layers of Required Area 0.2275 in2/ft #4@ 0.00 in 94@ 0.00 in Provided Area 0.62 in2/ft #5@ 0.00 in #5@ 0.00 in M6ximum Area: 0.7704 in2/ft #6@ 0.00 in #6@ 0.00 in Bottom Stem Vertical Reinforcing Horizontal Reinforcing As (based on applied moment): 0.4795 in2/ft (4/3) * As: 0.6393 in2/ft Min Stem T&S Reinf Area 0.447 in2 200bd/fy : 200(12)(5.687)/60000 0.2275 in2/ft Min Stem T&S Reinf Area perft of stem Height: 0.192 in2/ft 0.0012bh: 0.0012(12)(8): 0. 1152 in2/ft Horizontal Reinforcing Options: One layer of : Two layers of Required Area 0.4795 in2/ft #4@ 12.50 in #4@ 25.00 in Provided Area 0.62 in2/ft #5@ 19.38 in #5@ 38.75 in Maximum Area: 0.7704 in2/ft #6@ 27.50 in #6@ 55.00 in Footing Dimensions & Strengths g Design Results No Toe Width .4.17 ft Toe Heel MW Heel Width 1.83 Factored Pressure �_'q 9 9 0 psf Total Footing Width 6.00 Mu': Upward 15,450 0 ft_# 110 Footing Thickness 12.00 in Mu': Downward 2,707 930 ft-# Key Width 12.00 in Mu: Design 12,743 930 ft-# Key Depth 18.00 in Actual 1 -Way Shear = 40.07 13.30 psi Key Distance from Toe 0.00 ft Allow 1-Way Shear = 75.00 40.00 psi Toe Reinforcing = # 5 @ 6.00 in fc 2,500 psi Fy 60,000 psi Heel Reinforcing = None Spec'd Footing Concrete Density 150.00 pcf Key Reinforcing = None Spec'd Min. As % 0,0018 Other Acceptable Sizes & Spacings Cover @ Top 2.00 @ Btm.= 3.50 in ps Toe: #4@ 6.51 in, #5@ 10.09 in, #6@ 14.32 in, #7@ 19.53 in, #8@ 25.71 in, #9@ 32 Heel: Not req'd: Mu < phi*5*lambda*sqrt(fc)*Sm . Key: Not req'd: Mu < phi*5*lambda*sqrt(fc)*Sm bw Min footing T&S reinf Area 1.73 in2 INN Min footing T&S reinf Area per foot O�29 in2 tft If one layer of horizontal bars: If two layers of horizontal bars: #4@ 8.33 in #4@ 16.67 in #5@ 12.92 in #5@ 25.83 in #6@ 18.33 in #6@ 36.67 in W No in wo ,go b" imo RetainPro (c) 1987-2017, Build 11.17.07.27 License : KW-06057724 Cantilevered Retaining Wall Cocke: IBC 2015ACI 318-14,ACI 530-13 License To: SOUND STRUCTURAL SOLUTIONS, INC Summary of Overturnina & Resistina F rces & Moments OVERTURNING.. ..... RESISTING ..... Force* Distance "kioment Force Distance Moment Item lbs ft ft-# lbs ft ft-# Heel Active Pressure 2,250.0 3.33 7,500.0 Surcharge over Heel Surcharge Over Toe Adjacent Footing Load Added Lateral Load Load @ Stem Above Soil Seismic Earth Load 490.0 5.00 2,450.0 6w Total 2,740.0 O.T.M. 9,950.0 Res isti n g/Overturning Ratio 1.41 Vertical Loads used for Soil Pressure 3.637.8 lbs two go .=a If seismic is included, the OTM and sliding ratios be 1.1 per section 1807.2.3 of IBC 2009 or IBC 201 Vertical component of active lateral soil pressure IS considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS considered in the calculation of Overturning Resistance. Soil Over Heel 1,154.7 b.42 6,253.5 Sloped Soil Over Heel Surcharge Over Heel Adjacent Footing Load = Axial Dead Load on Stem = Axial Live Load on Stem = Soil Over Toe 458.3 2.08 954.6 Surcharge Over Toe Stem Weight(s) 900.0 4.50 4,049.4 Earth @ Stem Transitions Footing Weight 899.9 3.00 2,699.1 Key Weight 225.0 0.50 112.5 Vert. Component 6.00 Total 3,637.8 lbs R,M.= 14,069.1 Axial live load NOT included in total displayed, or used for overturning resistance, but is included for soil pressure calculation. Tilt I Horizontal Deflection at Top of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 250.0 pci Horizontal Defl @ Top of Wall (approximate only) 0.089 in The above calculation is not valid if the heel soil bearing pressure exceeds that of the toe because the wall would then tend to rotate into the retained soil. RetainPro (c) 1987-2017, Build 11.17.07.27 License: KW-06057724 Cantilevered Retaining Wall Code: IBC 2015ACI 318-14ACI 530-13 License To: SOUND STRUCTURAL SOLUTIONS, INC Criteria [Soil Data MMT� mmmT07000.0 psf Retained Height 9.00 ft Allow Soil Bearing Wall height above soil 0.00 ft Equivalent Fluid Pressure Method Active Heel Pressure 45.0 psf/ft Slope Behind Wall 0.00 Height of Soil over Toe 12.00 in Water height over heel = 0.0 ft Surcharge Loads Surcharge Over Heel 0,0 psf Used To Resist Sliding & Overturning Surcharge Over Toe 0.0 psf Used for Sliding & Overturning [Aiial Load Applied to SteLmLLJ Axial Dead Load 0.0 lbs Axial Live Load 0.0 lbs Axial Load Eccentricity 0.0 in Design Summary Wall Stability Ratios Overturning 1.88 OK Sliding 1.54 OK Total Bearing Load 3,638 lbs ... resultant ecc. 14 32 in Soil Pressure @ Toe 1,343 psf OK Soil Pressure @ Heel 0 psf OK Allowable 2,000 psf Soil Pressure Less Than Allowable ACI Factored @ Toe 1,880 psf ACI Factored @ Heel 0 psf Footing Shear @ Toe 33.4 psi OK Footing Shear @ Heel 12.8 psi OK Allowable 75.0 psi Sliding CaIcs Lateral Sliding Force 2,250.0 lbs less 100% Passive Force 1,837.5 lbs less 100% Friction Force 1,63,7.0 lbs Added Force Req'd ao lbs OK .... for 1.5 Stability 0.0 lbs OK Vertical component of active lateral sal pressure IS considered in the calculation of soil bearing pressures. Load Factors - Building Code Dead Load Live Load Earth, H Wind, W Seismic, E I BC 2G1 5,ACI 1.200 1.600 1.600 1.000 1.000 Passive Pressure 300.0 psf/ft Soil Density, Heel = 110.00 Pcf Soil Density, Toe = 110.00 pcf FootingIlSoil Friction 0.450 Soil height to ignore for passive pressure 0.00 in F-Lateral Load Applied to Stem Lateral Load 0.0 #/ft ... Height to Top 0.00 ft ... Height to Bottom 0.00 ft Load Type = Wind (W) (Service Level) Wind on Exposed Stem = 0.0 psf (Service Level) [Adjacent Footing Load Adjacent Footing Load 0.0 lbs Footing Width 0.00 ft Eccentricity 0.00 in Wall to Ftg CL Dist 0.00 ft Footing Type Line Load Base Above/Below Soil at Back of Wall 0.0 ft Poisson's Ratio 0.300 Stem Construction 3rd Stem OK Design Hel;ht Above Ftg ft = 2.33 Wall Material Above "Ht" = Concrete Design Method LRFD Thickness 8.00 Rebar Size # 5 Rebar Spacing 12.00 Rebar Placed at 5.687 Design Data fb/FB + fa/Fa 0.430 Total Force @ Section Service Level lbs = Strength Level lbs = 1,601.6 Moment .... Actual Service Level ft-# = Strength Level ft-# = 3,560.9 Moment ..... Allowable ft-# = 7,423.1 Shear ..... Actual Service Level psi = Strength Level psi = 23.5 Shear ..... Allowable psi = 75.0 Anet (Masonry) in2 = Rebar Depth 'd' in= 5.69 Masonry Data fm psi = Fs psi = Solid Grouting Modular Ratio'n' Wall Weight psf 100.0 Short Term Factor Equiv. Solid Thick. Masonry Block Type = Medium Masonry Design Method = ASD Concrete Data fc psi = 2,500.0 Fy psi = 60,000.0 2nd Bottom Stem OK Stem OK 2.33 0.00 Concrete Concrete LRFD LRFD 8.00 8.00 # 5 # 5 6.00 6.00 5.687 Edge 0.258 0.633 1,601.6 2,916.0 3,560.9 8,748.0 13,825.6 13,825.6 23.5 42.7 75.0 75.0 5.69 5.69 100.0 100.0 �eight 2,500.0 2,500.0 60,000.0 60,000.0 FM M I" on No on oft 110 um pe on WW tod bow RetainPro (c) 1987-2017, Build 11.17.07.27 License : KW-06057724 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13 License To: SOUND STRUCTURAL SOLUTIONS, INC Concrete Stem Rebar Area Details 3rd Stem Vertical Reinforcing Horizontal Reinforcing As (based on applied moment): 0.1474 in2/ft (4/3) * As : 0.1965 in2/ft Min Stem T&S Reinf Area 1.281 in2 200bd/fy: 200(12)(5.687)/60000: 0.2275 in2/ft Min Stem T&S Reinf Area per it of stem Height: 0.192 in2/ft 0.0012bh : 0,0012(12)(8): 0. 1152 in2/ft Horizontal Reinforcing Options : One layer of : Two layers of Required Area 0.1965 in2/ft #4@ 12.50 in #4@ 25.00 in Provided Area 0.31 in2/ft #5@ 19.38 in #5@ 38.75 in Maximum Area: 0.7704 in2/ft #6@ 27.50 in #6@ 55.00 in 2nd Stem Vertical Reinforcing As (based on applied moment): 0.1474 in2/ft (4/3) * As : 0. 1965 in2/ft 200bd/fy: 200(12)(5.687)/60000: 0.2275 in2/ft 0.0012bh : 0.0012(12)(8): 0. 1152 in2/ft Required Area 0. 1965 in2/ft Provided Area 0.62 in2/ft Maximum Area: 0.7704 in2/ft Horizontal Reinforcing Min Stern T&S Reinf Area 0.000 in2 Min Stem T&S Reinf Area perft of stem Height: 0.000 in2/ft Horizontal Reinforcing Options: One layer of Two layers of #4@ 0.00 in #4@ 0.00 in #5@ 0.00 in #5@ 0.00 in #6@ 0.00 in #6@ 0.00 in Bottom Stem Vertical Reinforcing Horizontal Reinforcing As (based on applied moment): 0.3621 in2/ft (4/3) * As : 0.4828 in2/ft Min Stem T&S Reinf Area 0.447 in2 200bd/fy: 200(12)(5.687)/60000: 0.2275 in2/ft Min Stem T&S Reinf Area per ft of stem Height: 0.192 in2/ft 0.0012bh : 0.0012(12)(8): 0. 1152 in2/ft Horizontal Reinforcing Options: One layer of: Two layers of Required Area 0.3621, in2/ft #4@ 12.50 in #4@ 25.00 in Provided Area 0.62 in2/ft #5@ 19.38 in #5@ 38.75 in Maximum Area: 0.7704 in2/ft #6@ 27.50 in #6@ 55.00 in Footing Dimensions & St-re-ng-t-h-sA Footing Design Results A Toe Width 4.17 ft Toe Heel Heel Width 1.83 Factored Pressure 1,880 0 psf Total Footing Width 6.00 Mu': Upward 12,134 12 ft-# Footing Thickness 12.00 in Mu': Downward 2,707 930 ft-# Mu: Design 9,426 919 ft-# Key Width Key Depth 12.00 in 18.00 in Actual 1-Way Shear = 33.42 12.80 psi Key Distance from Toe 0.00 ft Allow 1-Way Shear = 75.00 40.00 psi Toe Reinforcing = # 5 @ 6.00 in fc 2,500 psi Fy = 60,000 psi Heel Reinforcing = None Spec'd Footing Concrete Density = 150.00 pcf Key Reinforcing = None Spec'd Min. As % 0.0018 Other Acceptable Sizes & Spacings Cover @ Top 2.00 @ Btm.= 3.50 in Toe: #4@ 7.50 in, #5@ 11.63 in, #6@ 16.50 in, #7@ 22.50 in, #8@ 29.63 in, #9@ 37 Heel: Not req'd: Mu < phi*5*lambda*sqrt(fc)*Sm Key: Not req'd: Mu < phi*5*lambda*sqrt(fc)*Sm Min footing T&S reinf Area 1.73 in2 Min footing T&S reinf Area per foot 0.29 in2 A If one layer of horizontal bars: If two layers of horizontal bars: #4@ 8.33 in #4@ 16.67 in #5@ 12.92 in #5@ 25.83 in #6@ 18.33 in #6@ 36.67 in on 1 6w RetainPro (c) 1987-2017, Build 11.17.07.27 License : KW-06057724 Cantilevered Retaining Wall Code: IBC 20115ACI 318-14ACI 530-13 License To: SOUND STRUCTURAL SOLUTIONS, INC Summa of Overturning & Resisting Forces & Moments ..... OVERTURNING .... koment ..... RESISTING ..... Force Distance Force Distance Moment Item lbs ft ft-# lbs ft ft-# Heel Active Pressure 2,250 D 3.33 7,500.0 Soil Over Heel 1,154.7 5.42 6,253.5 Surcharge over Heel Surcharge Over Toe Adjacent Footing Load Added Lateral Load Load @ Stem Above Soil Total 2,250.0 O.T.M. 7,500.0 Resisting/Overturning Ratio 1.88 Vertical Loads used for Soil Pressure 3,637.8 lbs Sloped Soil Over Heel Surcharge Over Heel Adjacent Footing Load = Axial Dead Load on Stem = Axial Live Load on Stem = Soil Over Toe 458.3 2.08 954.6 Surcharge Over Toe Stem Weight(s) 900.0 4.50 4,049.4 Earth @ Stem Transitions Footing Weight 899.9 3.00 2,699.1 Key Weight 225.0 0.50 112.5 Vert. Component 6.00 Total 3,637.8 lbs R.M.= 14,069.1 Axial live load NOT included in total displayed, or used for overturning resistance, but is included for soil pressure calculation. Vertical component of active lateral soil pressure IS considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS considered in the calculation of Overturning Resistance. Tilt Horizontal Deflection at Tot) of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 250.0 pci Horizontal Deft @ Top of Wall (approximate only) 0.056 in The above calculation is not valid if the heel soil bearing pressure exceeds that of the toe because the wall would then tend to rotate into the retained soil. r iw Pit RetainPro (c) 1987-2017, Build 11.17.07.27 License : KW'06057724 Cantilevered Retaining Wall Code: IBC 2015ACI 318-14ACI 530-13 icense To: SOUND STRUCTURAL SOLUTIONS, INC I Criteria FS-Oil Data Retained Height 8.00 ft Allow Soil Bearing 2,666.0 psf Wall height above soil 0.00 ft Equivalent Fluid Pressure Method Active Heel Pressure 45.0 psf/ft Slope Behind Wall 0.00 Height of Soil over Toe 12.00 in Water height over heel 0.0 ft Passive Pressure 300.0 psf/ft Surcharge Loads Surcharge Over Heel 0.0 psf Used To Resist Sliding & Overturning Surcharge Over Toe 0.0 psf Used for Sliding & Overturning Axial Load Applied to Stem Axial Dead Load 0.0 lbs Axial Live Load 0.0 lbs Axial Load Eccentricity 0.0 in Earth Pressure Seismic L Method : Uniform Multiplier Used 7.000 (Multiplier used on soil density) Design Summary Wall Stability Ratios Overturning 1.33 Ratio < Sliding 1.30 Ratio < Total Bearing Load 2,838 lbs ... resultant ecc. 20.38 in Soil Pressure @ Toe 2,360 psf OK Soil Pressure @ Heel 0 psf OK Allowable 2,666 psf Soil Pressure Less Than Allowable ACI Factored @ Toe 3,305 psf ACI Factored @ Heel 0 psf Footing Shear @ Toe 42.3 psi OK Footing Shear @ Heel 12.6 psi OK Allowable 75.0 psi Sliding CaIcs Lateral Sliding Force 2,138.0 lbs less 100% Passive Force 1,504.2 lbs less 100% Friction Force 1,276.9 lbs Added Force Req'd 0.0 lbs OK .... for 1.5 Stability 425.9 lbs NG Soil Density, Heel = 110.00 pof Soil Density, Toe = 110.00 pcf Footingl]Soil Friction 0.450 Soil height to ignore for passive pressure 0.00 in FLateral Load Applied to Stem Lateral Load 0.0 #/ft ... Height to Top 0.00 ft .-Height to Bottom 0.00 ft Load Type = Wind (W) (Service Level) Wind on Exposed Stem = 0.0 psf (Service Level) Uniform Seismic Force = 61.833 Total Seismic Force = 546.194 Ilem Constr Design Height Above Ftg ft 1.5! Wall Material Above "Ht" 1.5! n-; � KA.th-j �1 Thickness Rebar Size Rebar Spacing Rebar Placed at Design Data fb/FB + fa/Fa Total Force @ Section Service Level lbs = Strength Level lbs = Moment .... Actual Service Level ft-# = Strength Level ft-# = Moment ..... Allowable ft-# = Shear ..... Actual Service Level psi = Strength Level psi = Shear ..... Allowable psi = Anet (Masonry) in2 = Rebar Depth 'd' in= Masonry Data fm psi = Fs psi = Solid Groutino Vertical component of active lateral soil pressure IS Modular Ratio'n' considered in the calculation of soil bearing pressures. %A/ 11 1A1 ; k4 r Load Factors - Building Code Dead Load Live Load Earth, H Wind, W Seismic, E IBC 2015,ACI 1.200 1.600 1.600 1.000 1.000 . e g ps - Short Term Factor 3rd Adjacent Footing Load Adjacent Footing Load 0.0 lbs Footing Width 0.00 ft Eccentricity 0.00 in Wall to Ftg CL Dist 0.00 ft Footing Type Line Load Base Above/Below Soil at Back of Wall 0.0 ft Poisson's. Ratio 0.300 2nd Bottom Stem OK Stem OK Stem OK 2.33 2 , 33 0 . 00 Concrete Concrete Concrete LRFD LRFD LRFD 8.00 8.010 8.00 # 5 # 5 # 5 12.00 6.00 6.00 5.687 5.687 Edge 0.429 0.230 0.588 1,508.0 1,508.0 2,798.7 3,181.3 3,181.3 8,122.7 7,423.1 13,825.6 13,825.6 22.1 22A 41.0 75.0 75,0 75.0 5.69 5.69 5.69 100.0 100:0 100.0 Equiv. Solid I HICK. Masonry Block Type = Medium Weight Masonry Design Method = ASD Concrete Data fc psi = Fy psi = 2,500.0 2,500.10 2,500.0 60,000.0 60,000D 60,000.0 RetainPro (c) 1987-2017, Build 11.17.07.27 License: KW-06057724 Cantilevered Retaining Wall Code: 113C 2015ACI 318-14,ACI 530-13 M License To: SOUND STRUCTURAL SOLUTIONS, INC Concrete Stem Rebar Area Details 3rd Stem Vertical Reinforcing Horizontal Reinforcing As (based on applied moment): 0.1317 in2/ft (4/3) * As: 0.1756 in2/ft Min Stem T&S Reinf Area 1.089 in2 200bd/fy: 200(12)(5.687)/60000 0.2275 in2/ft Min Stem T&S Reinf Area per ft of stem Height: 0. 192 in2/ft 0.0012bh : 0.0012(12)(8): 0. 1152 in2/ft Horizontal Reinforcing Options: One layer of: Two layers of too Required Area 0.1756 in2/ft #4@ 12.50 in #4@ 25.00 in Provided Area 0.31 in2/ft #5@ 19.38 in #5@ 38.75 in Maximum Area: 0.7704 in2/ft #6@ 27.50 in #6@ 55.00 in 2nd Stem Vertical Reinforcing Horizontal Reinforcing As (based on applied moment): 0. 1317 in2/ft (4/3) * As : 0.1756 in2/ft Min Stem T&S Reinf Area 0.000 in2 200bd/fy: 200(12)(5.687)160000: 0.2275 in2/ft Min Stem T&S Reinf Area per ft of stem Height: 0.000 in2/ft 0.0012bh : 0.0012(12)(8): 0. 1152 in2/ft Horizontal Reinforcing Options : One layer of Two layers of Required Area 0. 1756 in2/ft #4@ 0.00 in #4@ 0.00 in Provided Area 0.62 in2/ft #5@ 0.00 in #5@ 0.00 in Maximum Area: 0.7704 in2/ft #6@ 0.00 in #6@ 0.00 in Bottom Stem Vertical Reinforcing Horizontal Reinforcing As (based on applied moment): 0.3362 in2/ft (4/3) * As: 0.4483 in2/ft Min Stem T&S Reinf Area 0.447 in2 200bd/fy: 200(12)(5.687)/60000 0.2275 in2/ft Min Stem T&S Reinf Area per ft of stem Height: 0.192 in2/ft 0.0012bh : 0.0012(12)(8): 0. 1152 in2/ft Horizontal Reinforcing Options: One layer of : Two layers of Required Area 0.3362 in2/ft #4@ 12.50 in #4@ 25.00 in Provided Area 0.62 in2/ft #5@ 19.38 in #5@ 38.75 in Maximum Area: 0.7704 in2/ft #6@ 27.50 in #6@ 55.00 in Footing Dimensions & Strengths Footing Design Results Toe Width 3.33 ft Toe Heel Heel Width 1.67 Factored Pressure �,305 0 psf Total Footing Width 5.00 Mu': Upward 10,057 0 ft_# P0 Footing Thickness 10.00 in Mu': Downward 1,566 602 ft-# Mu: Design 8,491 602 ft-# Key Width 40.00 in Actual 1 -Way Shear = 42.35 12.55 psi Key Depth 16.00 in Allow 1 -Way Shear = 75.00 40.00 psi Key Distance from Toe 0.00 ft Toe Reinforcing = # 5 @ 6.00 in fc = 2,500 psi Fy 60,000 psi Heel Reinforcing = None Spec'd Footing Concrete Density 150.00pcf Key Reinforcing = None Spec'd Min. As % 0.0018 Other Acceptable Sizes & Spacings Cover @ Top 2.00 @ Btm.= 3.50 in Toe: #4@ 7.23 in, #5@ 11.20 in, #6@ 15.90 in, #7@ 21.68 in, #8@ 28.54 in, #9@ 36 Heel: Not req'd: Mu < phi*5*lambda*sqrt(fcrsm Key: Not req'd: Mu < phi*5*lambda*sqrt(fc)*Sm Min footing T&S reinf Area 1.20 in2 Min footing T&S reinf Area per foot 0.24 in2 /ft If one layer of horizontal bars: If two layers of horizontal bars: #4@ 10.00 in #4@ 20.00 in #5@ 15.50 in #5@ 31.00 in #6@ 22.00 in #6@ 44.00 in low MIN aw so ftw so low r �00 RetainPro (c) 1987-2017, Build 11.17.07.27 License: KW-06057724 Cantilevered Retaining Wall Code: IBC 2015ACI 318-14ACI 530-13 License To: SOUND STRUCTURAL SOLUTIONS, INC Summary of Overturning & Resisting Forces & Moments J ..... OVERTURNING ..... ..... RESISTING ..... Force Distance Moment Force Distance Moment Item lbs ft ft-# ibs It ft-# Heel Active Pressure 1,755.6 2.94 5,169.3 Soil Over Heel 879.4 4.50 3,956..8 Surcharge over Heel Surcharge Over Toe Adjacent Footing Load Added Lateral Load Load @ Stem Above Soil Seismic Earth Load 382.3 4.42 1,688.7 Total 2,138.0 O.T.M. 6,858.0 Resist! ng/Overturning Ratio 1.33 Vertical Loads used for Soil Pressure 2,837.6 lbs Sloped Soil Over Heel Surcharge Over Heel Adjacent Footing Load = Axial Dead Load on Stem = Axial Live Load on Stem = Soil Over Toe 366.6 1.67 61 1.0 Surcharge Over Toe Stem Weight(s) 800.0 3.67 2,933.1 Earth @ Stem Transitions Footing Weight 624.9 2.50 1,561.!g Key Weight 166.7 0.42 69A Vert. Component 5.00 Total 2,837.6 lbs R.M.= 9,132.1 If seismic is included, the OTM and sliding ratios Axial live load NOT included in total displayed, or used for overturning be 1 .1 per section 1807.2.3 of IBC 2009 or IBC 201 resistance, but is included for soil pressure calculation. Vertical component of active lateral soil pressure IS considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS considered in the calculation of Overturning Resistance. Horizontal Deflection at Top of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 250.0 pci Horizontal Defl @ Top of Wall (approximate only) 0.105 in The above calculation is not valid if the heel soil bearing pressure exceeds that of the toe, because the wall wo,uld then tend to rotate into the retained soil, RetainPro(c)1987-2017, Build 11.17.07.27 License: KW-06DS7724 Cantilevered Retaining Wall Code: IBC 20115ACI 318-14ACI 530-13 License To: SOUND STRUCTURAL SOLUTIONS, INC Criteria [Soil Data Retained Height 8.00 ft Allow Soil Bearing 2,000.0 psf Wall height above soil 0.00 ft Equivalent Fluid Pressure Method Slope Behind Wall 0.00 Active Heel Pressure 45.0 psf/ft Height of Soil over Toe 12,00 in Water height over heel = 0.0 ft Surcharge Loads Surcharge Over Heel 0.0 psf Used To Resist Sliding & Overturning Surcharge Over Toe 0.0 psf Used for Sliding & Overturning [Axial Load Applied to Stem Axial Dead Load -M 0.0 lbs Axial Live Load 0.0 lbs Axial Load Eccentricity 0.0 in Design Summary Wall Stability Ratios Overturning 1 77 OK Sliding 1.58 OK Total Bearing Load 2,838 lbs ... resultant ecc. 13,24 in Soil Pressure @ Toe 1,355 psf OK Soil Pressure @ Heel 0 psf OK Allowable 2,000 psf Soil Pressure Less Than Allowable ACI Factored @ Toe 1,896 psf ACI Factored @ Heel 0 psf Footing Shear @ Toe 36.6 psi OK Footing Shear @ Heel 12.5 psi OK Allowable 75.0 psi Sliding Caics Lateral Sliding Force 1,755.6 lbs less 100% Passive Force = 1,504.2 lbs less 100% Friction Force = 1,276.9 lbs Added Force Req'd 0.0 lbs OK .... for 1.5 Stability 0.0 lbs OK Vertical component of active lateral soil pressure IS considered in the calculation of soil bearing pressures. Load Factors - Building Code Dead Load Live Load Earth, H Wind, W Seismic, E IBC 2015,ACI 1.200 1.600 1.600 1.000 1.000 Passive Pressure 300.0 psf/ft Soil Density, Heel = 110.00 pcf Soil Density, Toe = 110.00 pef FootingIlSoil Friction 0.450 Soil height to ignore for passive pressure 0.00 in ateral Load Applied to Stem Lateral Load 0.0 #/ft ... Height to Top 0.00 ft ... Height to Bottom 0.00 ft Load Type = Wind (W) (Service Level) Wind on Exposed Stem = 0.0 psf (Service Level) r--1 [Adjac nt Footing Load Adjacent Footing Load 0.0 lbs Footing Width 0.00 ft Eccentricity 0.00 in Wall to Fig CL Dist 0.00 it Footing Type Line Load Base Above/Below Soil at Back of Wall 0.0 ft Poisson's Ratio 0.300 Stem Construction 3rd Stem OK Design Height Above Ftg ft = 2.33 Wall Material Above "Ht" = Concrete Design Method LRFD Thickness 8.00 Rebar Size # 5 Rebar Spacing 12,00 Rebar Placed at 5,687 Design Data fb/FB + fa/Fa 0.295 Total Force @ Section Service Level lbs = Strength Level lbs = 1,157.4 Moment .... Actual Service Level ft-# = Strength Level ft-# = 2,187.4 Moment ..... Allowable ft-# = 7,423.1 Shear ..... Actual Service Level psi = Strength Level psi = 17.0 Shear ..... Allowable psi = 75.0 Anet (Masonry) in2 = Rebar Depth 'd' in = 5.69 Masonry Data fm psi = Fs psi = Solid Grouting Modular Ratio'n' Wall Weight psf 100.0 Short Term Factor Equiv. Solid Thick. Masonry Block Type = Medium W Masonry Design Method = ASD Concrete Data fc psi = 2,500.0 Fy psi = 60,000.0 2nd Bottom Stem OK Stem OK 2.33 0.00 Concrete Concrete LRFD LRFD 8.00 8.00 # 5 # 5 6.00 6.00 5.687 Edge 0.158 0.444 1,157.4 2,304.0 2,187.4 6,144.0 13,825.6 13,825.6 17.0 33.8 75.0 75.0 5.69 5.69 100.0 eight 100.0 2,500.0 2,500.0 60,000.0 60,000.0 11" W.i Pill INN WN 140 ow 10" no 1110 wo OR saw go JIM NA N" 111111111 RetainPro (c) 1987-2017, Build 11.17.07.27 License: KW-06057724 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13 License To: SOUND STRUCTURAL SOLUTIONS, INC Concrete Stem Rebar Area Details so 3rd Stem Vertical Reinforcing Horizontal Reinforcing As (based on applied moment): 0.0905 in2/ft (4/3) * As: 0.1207 in2/ft Min Stein T&S Reirif Area 1.089 in2 200bd/fy: 200(12)(5.687)/60000 0.2275 in2/ft Min Stein T&S Reirif Area per ft of stem Height: 0,192 in2/ft 0.0012bh: 0.0012(12)(8): 0. 1152 in2/ft Horizontal Reinforcing Options Wool One layer of : Two layers of Required Area 0.1207 in2/ft #4@ 12,50 in #4@ 25.00 in Provided Area 0.31 in2/ft #5@ 19,38 in #5@ 38.75 in i Maximum Area: 0.7704 in2/ft #6@ 27.50 in #6@ 55,00 in W" 2nd Stem Vertical Reinforcing Horizontal Reinforcing As (based on applied moment): 0.0905 in2/ft tow (4/3) * As : 0. 1207 in2/ft Min Stem T&S Reinf Area 0.000 in2 200bd/fy: 200(12)(5.687)/60000: 0.2275 in2/ft Min Stern T&S Reinf Area per ft of stem Height: 0.000 in2/ft 0.0012bh : 0.0012(12)(8): 0. 1152 in2/ft Horizontal Reinforcing Options: One layer of: Two layers of Required Area 0.1207 in2/ft #4@ 0.00 in #4@ 0.00 in Provided Area 0.62 in2/ft #5@ 0.00 in #5@ 0.00 in Maximum Area: 0.7704 in2/ft #6@ 0.00 in #6@ 0.00 in ism Bottom Stem Vertical Reinforcing Horizontal Reinforcing As (based on applied moment): 0.2543 in2/ft (4/3) * As: 0.3391 in2/ft Min Stem T&S Reirif Area 0.447 in2 200bd/fy 200(12)(5.687)160000: 0.2275 in2/ft Min Stem T&S Reirif Area per ft of stem Height: 0.192 in2/ft 0.0012bh 0.0012(12)(8): 0. 1152 in2/ft Horizontal Reinforcing Options : One layer of : Two layers of: Required Area 0.2543 in2/ft #4@ 12.50 in #4@ 25.00 in Provided Area 0.62 in2/ft #5@ 19.38 in #5@ 38.75 in Maximum Area: 0.7704 in2/ft #6@ 27.50 in #6@ 55.00 in Footing Dimensions & Stmen-g-th-sA Footing Design Results Toe Width 3.33 ft Toe Heel Heel Width 1.67 Factored Pressure 1,896 0 psf Total Footing Width 5.00 Mu': Upward 7,740 1 ft-# Footing Thickness Mu': Downward 10.00 in 1,566 602 ft-# Key Width Mu: Design 6,174 602 ft-# 10.00 in Key Depth Actual 1-Way Shear = 36.56 12.47 psi 16.00 in Key Distance from Toe Allow 1 -Way Shear = 75.00 40.00 psi 0.00 ft Toe Reinforcing = # 5 @ 6.00 in fc 2,500 psi Fy 60,000 psi Heel Reinforcing = None Spec'd Footing Concrete Density 150.00pcf Key Reinforcing = None Spec'd Min. As % 0.0018 Other Acceptable Sizes & Spacings Cover @ Top 2.00 @ Btm.= 3.50 in Toe: #4@ 9.94 in, #5@ 15.40 in, #6@ 21.86 in, #7@ 29.81 in, #8@ 39.26 in, #9@ 49 Heel: Not req'd: Mu < phi*5*lambda*sqrt(fc)*Sm how Key: Not req'd: Mu < phi*5*lambda*sqrt(fc)*Sm Min footing T&S reirif Area 1.20 in2 Min footing T&S reirif Area per foot 0.24 in2 /ft If one layer of horizontal bars: If two layers of horizontal bars: #4@ 10.00 in #4@ 20.00 in #5@ 15.50 in #5@ 31.00 in #6@ 22.00 in #6@ 44.00 in 6w low RetainPro (c) 1987-2017, Build 11.17.07.27 License : KW-06057724 Cantilevered Retaining Wall Code: IBC 2015ACI 318-14,ACI 530-13 License To: SOUND STRUCTURAL SOLUTIONS, INC Summary of Overturning & Resisting orces & Moments ..... OVERTURNING ..... ..... RESISTING ..... Force Distance Moment Force Distance Moment Item lbs ft ft-# lbs ft ft-# Heel Active Pressure 1,755.6 2.94 5,169.3 Surcharge over Heel Surcharge Over Toe Adjacent Footing Load Added Lateral Load Load @ Stem Above Soil Total 1,755.6 O.T.M. 5,169.3 Res isti ng/Overturning Ratio 1.77 Vertical Loads used for Soil Pressure 2,837.6 lbs Soil Over Heel 879.4 4.0u 3,956.8 Sloped Soil Over Heel Surcharge Over Heel Adjacent Footing Load = Axial Dead Load on Stem = Axial Live Load on Stem = Soil Over Toe 366.6 1.67 611.0 Surcharge Over Toe Stem Weight(s) 800.0 3.67 2,933.1 Earth @ Stem Transitions Footing Weight 624.9 2.50 1,561.9 Key Weight 166.7 0.42 69.4 Vert. Component 5.00 Total 2,837.6 lbs R.M.� 9,132.1 Axial live load NOT included in total displayed, or used for overturning resistance, but is included for soil pressure calculation. Vertical component of active lateral soil pressure IS considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS considered in the calculation of Overturning Resistance. Tilt Horizontal Deflection at'Tog) of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 250.0 pci Horizontal Defl @ Top of Wall (approximate only) 0.060 in The above calculation is not valid: if the heel soil bearing pressure exceeds that of the toe because the wall would then tend to rotate into the retained soil. r �Wd FIR LW RetainPro(c)1987-2017, Build 11.17.07.27 License: KW-06057724 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 53CI-13 License To: SOUND STRUCTURAL SOLUTIONS, INC �c riteria Soil Data Retained Height 6.67 ft Allow Soil Bearing �2,666.0 psf Wall height above soil 0.00 ft Equivalent Fluid Pressure Method Active Heel Pressure 45.0 psf/ft Slope Behind Wall 0.00 Height of Soil over Toe 8.00 in Water height over heel 0.0 ft Passive Pressure 300.0 psf/ft Surcharge Loads Surcharge Over Heel 0.0 psf NOT Used To Resist Sliding & Overturning Surcharge Over Toe 0.0 psf Used for Sliding & Overturning Axial Load Applied to Stem Axial Dead Load 0.0 lbs Axial Live Load 0.0 lbs Axial Load Eccentricity 0.0 in [Earth -Pressure Seismic Load Method : Uniform Multiplier Used 7.000 (Multiplier used on soil density) Design Summary Wall Stability Ratios Overturning 1.33 Ratio < Sliding 1.25 Ratio < Total Bearing Load 2,195 lbs ... resultant ecc. 16.36 in Soil Pressure @ Toe 2,301 psf OK Soil Pressure @ Heel 0 psf OK Allowable 2,666 psf Soil Pressure Less Than Allowable ACI Factored @ Toe 3,222 psf ACI Factored @ Heel 0 psf Footing Shear @ Toe 35.8 psi OK Footing Shear @ Heel 10.7 psi OK Allowable 75.0 psi Sliding Cales Lateral Sliding Force 1,541.0 lbs less 100% Passive Force 937.5 lbs less 100% Friction Force 987.9 lbs Added Force Req'd 0.0 lbs OK .... for 1.5 Stability 386.1 lbs NG Soil Density, Heel = 110.00 pcf Soil Density, Toe = 110.00 pcf FootingIlSoil Friction 0.450 Soil height to ignore for passive pressure 0.00 in Lateral Load Applied t Lateral Load 0.0 #/ft ... Height to Top 0.00 ft ... Height to Bottom 0.00 ft Load Type = Wind (W) (Service Level) Wind on Exposed Stem = 0.0 psf (Service Level) Uniform Seismic Force = 52.495 Total Seismic Force = 393.680 FS-tern Construction Design Height Above Ftg ft 1.5! Wall Material Above "Ht" 1.5! n-i � NA.fh-f U Thickness Rebar Size Rebar Spacing Rebar Placed at Design Data fb/FB + fa/Fa Total Force @ Section Service Level lbs = Strength Level lbs = Moment .... Actual Service Level ft-# = Strength Level ft-# = Moment ..... Allowable ft-# = Shear ..... Actual Service Level psi = Strength Level psi = Shear ..... Allowable psi = Anet (Masonry) in2 = Rebar Depth 'd' in = Masonry Data fm psi = Fs psi = Solid Groutino Vertical component of active lateral soil pressure IS Modular Ratio 'n' considered in the calculation of soil bearing pressures. XAI It IAI ; � Load Factors - Building Code Dead Load Live Load Earth, H Wind, W Seismic, E IBC 2015,ACI 1.200 1.600 1.600 1.000 1.000 a eg L PSI Short Term Factor 3rd Adjacent Footing Load Adjacent Footing Load 0.0 1 bs-- Footing Width 0.00 ft Eccentricity 0.00 in Wall to Ftg CL Dist 0.00 ft Footing Type Line Load Base Above/Below Soil at Back of Wall 0.0 ft Poisson's Ratio 0.300 2nd Bottom Stem OK Stem OK Stem OK 2.33 2 . 33 0 . 00 Concrete Concrete Concrete LRFD LRFD LRFD 8.00 8.00 8.00 # 5 # 5 # 5 16.00 8.00 8.00 5.687 5.687 Edge 0.260 0.137 0.439 904.5 904.5 1,949.6 1,471.7 1,471.7 4,720.8 5,663.0 10,751 �9 10,751.9 13.3 13.3 28,6 75.0 75.0 75.0 5.69 5.69 5.69 100.0 100:0 100.0 Equiv. Solid I HICK. Masonry Block Type = Medium Weight Masonry Design Method = ASD Concrete Data fc psi = Fy psi = 2,500.0 2,500.10 2,500.0 60,000.0 60,000.,0 60,000.0 ON bw MR RetainPro (c) 1987-2017, Build 11.17.07.27 License: KW-06057724 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13 License To: SOUND STRUCTURAL SOLUTIONS, INC Concrete Stem Rebar Area Details 3rd Stem Vertical Reinforcing Horizontal Reinforcing PIP As (based on applied moment): 0.0609 in2/ft am (4/3) * As: 0.0812 in2/ft Min Stem T&S Reinf Area 0.833 in2 200bd/fy: 200(12)(5.687)/60000 0.2275 in2/ft Min Stem T&S Reinf Area per ft of stem Height: 0.192 in2/ft PE 0.0012bh: 0.0012(12)(8): 0. 1152 in2/ft Horizontal Reinforcing Options : One layer of : Two layers of: 11W Required Area 0. 1152 in2/ft #4@ 12.50 in #4@ 25.00 in Provided Area 0.2325 in2/ft #5@ 19.38 in #5@ 38.75 in PM Maximum Area: 0.7704 in2/ft #6@ 27.50 in #6@ 55.00 in bw 2nd Stem Vertical Reinforcing Horizontal Reinforcing As (based on applied moment): 0.0609 in2/ft PIP (4/3) * As : 0.0812 in2/ft Min Stem T&S Reinf Area 0.000 in2 200bd/fy: 200(12)(5.687)/60000: 0.2275 in2/ft Min Stem T&S Reinf Area per ft of stem Height: 0.000 in2/ft aw 0.0012bh : 0.0012(12)(8): 0. 1152 in2/ft Horizontal Reinforcing Options: One layer of Two layers of Required Area 0. 1152 in2/ft #4@ 0.00 in #4@ 0.00 in Provided Area 0.465 in2/ft #5@ 0.00 in #5@ 0.00 in Maximum Area: 0.7704 in2/ft #6@ 0.00 in #6@ 0.00 in Bottom Stem Vertical Reinforcing Horizontal Reinforcing As (based on applied moment): 0.1954 in2/ft (4/3) * As: 0.2606 in2/ft Min Stem T&S Reinf Area 0.447 in2 200bd/fy 200(12)(5,687)/60000 0.2275 in2/ft Min Stem T&S Reinf Area perft of stem Height: 0.192 in2/ft 0.0012bh 0.0012(12)(8): 0. 1152 in2/ft Horizontal Reinforcing Options: One layer of : Two layers of: Required Area 0.2275 in2/ft #4@ 12.50 in #4@ 25.00 in Provided Area 0.465 in2/ft #5@ 19.38 in #5@ 38.75 in Maximum Area: 0.7704 in2/ft #6@ 27.50 in #6@ 55.00 in Footing Dimensions & St Footing Design Results j Toe Width 2.33 ft Toe Heel Heel Width 1.67 Factored Pressure 3,222 0 psf Total Footing Width 4.00 Mu': Upward 5,216 0 ft-# Footing Thickness 10.00 in Mu': Downward 648 514 ft-# Mu: Design 4,568 514 ft-# Key Width 1:0.00 in Actual 1-Way Shear = 35.82 10.72 psi Key Depth 12.00 in Allow 1 -Way Shear = 75.00 40.00 psi Key Distance from Toe 0.00 ft Toe Reinforcing = # 5 @ 8.00 in fc = 2,500 psi Fy 60,000 psi Heel Reinforcing = None Spec'd Footing Concrete Density 150.00pcf Key Reinforcing = None Spec'd Min. As % 0.0018 Other Acceptable Sizes & Spacings Cover @ Top 2.00 @ Btm.= 3.50 in Toe: #4@ 10.07 in, #5@ 15.61 in, #6@ 22.16 in, #7@ 30.22 in, #8@ 39.79 in, #9@ 5 Heel: Not req'd: Mu < phi*5*lambda*sqrt(fc)*Sm Key: Not req'd: Mu < phi*5*lambda*sqrt(fc)*Sm Min footing T&S reinf Area 0.96 in2 Min footing T&S reinf Area per foot 0.24 in2 A If one layer of horizontal bars: If two layers of horizontal bars: #4@ 10.00 in #4@ 20.00 in #5@ 15.50 in #5@ 31.00 in #6@ 22.00 in #6@ 44.00 in 1111111 no IN ow ON an P" 6" low No RetainPro (c) 1987-2017, Build 11.17.07.27 License: KW-06057724 Cantilevered Retaining Wall License To: SOUND STRUCTURAL SOLUTIONS, INC Code: IBC 2015ACI 318-14ACI 530-13 Summary of Overturning & Resisting Forces & Moments ..... OVERTURNING ..... ..... RESISTING ..... Force Distance Moment Force Distance Moment Item lbs ft ft-# lbs ft ft-# Heel Active Pressure 1,265.4 2.50 3,163.2 Soil Over Heel 732.8 3.50 2,564.2 Surcharge over Heel Sloped Soil Over Heel Surcharge Over Toe Surcharge Over Heel Adjacent Footing Load Adjacent Footing Load = Added Lateral Load Axial Dead Load on Stem = Load @ Stem Above Soil Axial Live Load on Stem = Seismic Earth Load 275.6 3.75 1,033.3 Soil Over Toe 171.1 1.17 199.6 Surcharge Over Toe Total 1,541.0 O.T.M. 4,196.5 Stem Weight(s) 666.6 2.67 1,777A Earth @ Stem Transitions Footing Weight 499.9 Z00 999.5 Resisting/Overturning Ratio. 1.33 Key We ig ht 125.0 0.42 52.1 Vertical Loads used for Soil Pressure 2,195.3 lbs Vert. Component 4.00 Total 2,195.3 lbs R.M.= 5,592.7 If seismic is included, the OTM and sliding ratios Axial live load NOT included in total displayed, or used for overturning be 1.1 per section 1807.2.3 of 113C 2009 or IBC 201 resistance, but is included for soil pressure calculation, Vertical component of active lateral soil pressure IS considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS considered in the calculation of Overturning Resistance. Tilt i Horizontal Deflection at Too of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 250.0 pci Horizontal Defl @ Top of Wall (approximate only) 0.107 in The above calculation is not valid if the heel soil bearing pressure exceeds that oi the toe because the wall would then tend to rotate into the retained soil. RetainPro (c) 1987-2017, Build 11.17.07.27 License : KW-06057724 Cantilevered Retaining Wall License To: SOUND STRUCTURAL SOLUTIONS. INC Criteria Soil Data I Retained Height mwmm77.67ft Allow Soil Bearing 2,000.0 psf Wall height above soil 0.00 ft Equivalent Fluid Pressure Method Slope Behind Wall 0.00 Active Heel Pressure 45.0 psf/ft Height of Soil over Toe = 8.00 in Code: IBC 20115ACI 318-14,ACI 530-13 XM Water height over heel 0.0 ft Passive Pressure 300.0 psf/ft Soil Density, Heel = 110.00 pcf Soil Density, Toe = 110.00 Pcf FootingIlSoil Friction 0.450 Soil height to ignore for passive pressure 0.00 in Surcharge Loads F-Lateral Load Applied to Stem -A Adjac nt Footing Load Surcharge Over Heel 0.0 psf Lateral Load 0.0 #/ft Adjacent Footing Load 0.0 lbs NOT Used To Resist Sliding & Oveirturning ... Height to Top 0.00 ft Footing Width 0.00 ft Surcharge Over Toe 0.0 Psf ... Height to Bottom 0.00 ft Eccentricity 0.00 in Used for Sliding & Overturning Load Type = Wind (W) Wall to Ftg CL Dist 0.00 ft [Axial Load Applied to Ste (Service Level) Footing Type Line Load Base Above/Below Soil 0.0 ft Axial Dead Load 0.0 lbs Wind on Exposed Stem = 0.0 Psf at Back of Wall Axial Live Load 0.0 lbs (Service Level) Poisson's Ratio 0.300 Axial Load Eccentricity 0.0 in Design Summary Stem Construction 3rd 2nd Bottom Stem OK Stem OK Stem OK Wall Stability Ratios Design Height Above Ftg ft = 2.33 2.33 0.00 Overturning 1 77 OK Wall Material Above "Ht" = Concrete Concrete Concrete Sliding 1.52 OK Design Method LRFD LRFD LRFID Thickness 8.00 8.00 Total Bearing Load 2,1D5 lbs Rebar Size # 5 # 5 ... resultant ecc. 10 71 in Rebar Spacing 16.00 8.00 Soil Pressure @ Toe 1,322 psf OK Rebar Placed at Design Data 5.687 5.687 Soil Pressure @ Heel 0 psf OK fb/FB + fa/Fa 0.173 0.091 Allowable 2,GOO psf Total Force @ Section Soil Pressure Less Than Allowable ACI Factored @ Toe 1,851 psf Service Level lbs = ACI Factored @ Heel 0 Psf Strength Level lbs = 676.8 676.8 Footing Shear @ Toe 27.3 psi OK Moment .... Actual Service Level ft-# = Footing Shear @ Heel 10.4 psi OK Strength Level ft-# = 978.2 978.2 Allowable 75.0 psi Sliding CaIcs Moment ..... Allowable ft-# = 5,663.0 10,751.9 Lateral Sliding Force 1,265.4 lbs Shear ..... Actual less 100% Passive Force 93,7.5 lbs Service Level psi = less 100% Friction Force 987.9 lbs Strength Level psi = 9.9 9.9 Added Force Req'd 0.0 lbs OK Shear ..... Allowable psi = 75.0 75.0 .... for 1.5 Stability 0.0 lbs OK Anet (Masonry) in2 = Rebar Depth 'd' in= 5.69 5.69 Masonry Data fm psi = Fs psi = Solid Grouting Vertical component of active lateral soil pressure IS Modular Ratio'n' considered in the calculation of soil bearing pressures. Wall Wei ht f inn n inn n Load Factors - Building Code Dead Load Live Load Earth, H Wind, W Seismic, E IBC 20-15,ACI 1.200 1.600 1.600 1.000 1.000 Short Term Factor Equiv. Solid Thick. Masonry Block Type = Medium Weight Masonry Design Method = ASO Concrete Data fc psi = 2,500.0 2,500.0 Fy psi = 60,000.0 60,000.0 8.00 # 5 8.00 Edge 0.331 1,599.7 3,554.5 10,751.9 23.4 75.0 5.69 100.0 2,500.0 60,000.0 "M P" INN bm P" %W Ila No go No ISM no ON WW ow RetainPro(c)1987-2017, Build 11.117.07.27 License : KW-06057724 Cantilevered Retaining Wall Code: 16C 2015ACI 318-14,ACI 530-13 License To: SOUND STRUCTURAL SOLUTIONS, INC Concrete Stem Rebar Area Details 3rd Stem Vertical Reinforcing As (based on applied moment): 0.0405 in2/ft (413) * As : 0.054 in2/ft 200bd/fy: 200(12)(5.687)/60000: 0.2275 in2/ft 0.0012bh : 0.0012(12)(8): 0. 1152 in2/ft Required Area 0. 1152 in2/ft Provided Area 0.2325 in2/ft Maximum Area: 0.7704 in2/ft 2nd Stem Vertical Reinforcing As (based on applied moment): 0.0405 in2/ft (4/3) * As: 0.054 in2/ft 200bd/fy: 200(12)(5.687)/60000 0.2275 in2/ft 0.0012bh : 0.0012(12)(8): 0. 1152 in2/ft Required Area 0. 1152 in2/ft Provided Area 0.465 in2/ft Maximum Area: 0.7704 in2/ft Horizontal Reinforcing Min Stem T&S Reinf Area 0.833 in2 Min Stem T&S Reinf Area per ft of stem Height: 0.192 in2/ft Horizontal Reinforcing Options: One layer of : Two layers of #4@ 12.50 in #4@ 25.00 in #5@ 19.38 in #5@ 38.75 in #6@ 27.50 in #6@ 55.00 in Horizontal Reinforcing Min Stem T&S Reinf Area 0.000 in2 Min Stem T&S Reinf Area per ft of stem Height: 0.000 in2/ft Horizontal Reinforcing Options : One layer of Two layers of: #4@ 0.00 in #4@ 0.00 in #5@ 0.00 in #5@ 0.00 in #6@ 0.00 in #6@ 0.00 in Bottom Stem Vertical Reinforcing Horizontal Reinforcing As (based on applied moment) 0.1471 in2/ft (4/3) * As 0.1962 in2/ft Min Stem T&S Reinf Area 0.447 in2 k 1W 200bd/fy: 200(12)(5.687)/60000 0.2275 in2/ft Min Stern T&S Reinf Area per ft of stem Height: 0.192 in2/ft 0.0012bh : 0.0012(12)(8): 0. 1152 in2/ft Horizontal Reinforcing Options : One layer of: Two layers of: Required Area 0.1962 in2/ft #4@ 12.50 in #4@ 25.00 in bog Provided Area 0.465 in2/ft #5@ 19.38 in #5@ 38.75 in Maximum Area: 0.7704 in2/ft #6@ 27.50 in #6@ 55.00 in Footing Dimensions & Strengths Footing Design Results Toe Width 2.33 ft To: Heel Heel Width 1.67 Factored Pressure 7851 0 psf Total Footing Width 4.00 Mu': Upward 3,858 3 ft-# Footing Thickness 10.00 in Mu': Downward 648 514 ft-# 'NNW Key Width 10.00 in Mu: Design 3,211 511 ft-# Key Depth Actual 1 -Way Shear = 27.32 10.42 psi 12.00 in 1111" Key Distance from Toe Allow I -Way Shear = 75.00 40,00 psi 0.00 ft Toe Reinforcing = # 5 @ 8.00 in fc 2,500 psi Fy 60,000 psi Heel Reinforcing = None Spec'd Footing Concrete Density 150.00pcf Key Reinforcing = None Spec'd Min. As % Cover @ Top 2.00 @ Btm.= 0.0018 Other Acceptable Sizes & Spacings 3.50 in Toe: #4@ 11.11 in, #5@ 17.22 in, #6@ 24.44 in, #7@ 33.33 in, #8@ 43.89 in, #9@ 5 Heel: Not req'd: Mu < phi*5*lambda*sqrt(fc)*Sm Key: Not req'd: Mu < phi*5*lambda*sqrt(fc)*Sm Min footing T&S reinf Area 0.96 in2 Min footing T&S reinf Area per foot O�24 in2 /ft. 6" If one layer of horizontal bars: If two layers of horizontal bars: #4@ 10.00 in #4@ 20.00 in #5@ 15.50 in #5@ 31.00 in #6@ 22.00 in #6@ 44.00 in Fill P" No RetainPro (c) 1987-2017, Build 11.17.07.27 License: KW-06057724 Cantilevered Retaining Wall Code: IBC 20115ACI 318-14ACI 530-13 License To: SOUND STRUCTURAL SOLUTIONS, INC Summa of Overturning & Resisting Forces & Moments ..... OVERTURNING .... ..... RESISTING ..... Force Distance 6ment Force Distance Moment Item lbs ft ft-# lbs ft ft-# Heel Active Pressure Surcharge over Heel Surcharge Over Toe Adjacent Footing Load Added Lateral Load Load @ Stem Above Soil 1,265.4 2.50 3,163.2 Total 1,265A O.T.M. 3,163.2 Resist! ng/Overturning Ratio 1.77 Vertical Loads used for Soil Pressure 2,195.3 lbs Soil Over Heel 732.8 6.0u 2,564.2 Sloped Soil Over Heel Surcharge Over Heel Adjacent Footing Load = Axial Dead Load on Stem = Axial Live Load on Stem = Soil Over Toe 171.1 1.17 199.6 Surcharge Over Toe Stem Weight(s) 666.6 2.67 1,777.4 Earth @ Stem Transitions Footing Weight 499.9 2.00 999.5 Key Weight 125.0 0.42 52.1 Vert. Component 4.00 Total 2,195.3 lbs R.M.= 5,592.7 Axial live load NOT included in total displayed, or u�sed for overturning resistance, but is included for soil pressure calculation. Vertical component of active lateral soil pressure IS considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS considered in the calculation of Overturning Resistance. Tilt I Horizontal Deflection at Tor) of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 250.0 pci Horizontal Defl @ Top of Wall (approximate only) 0.061 in The above calculation is not valid if the heel soil bearing pressure exceeds that of the toe, because the wall would then tend to rotate into the retained soil, 0 r bw RetainPro(c)1987-2017, Build 11.17.07.27 License ; KW-06057724 Cantilevered Retaining Wall Code: IBC 2015ACI 318-14ACI 530-13 License To: SOUND STRUCTURAL SOLUTIONS, INC 1�c riteria Soil Data Retained Height 5.67 ft Allow Soil Bearing 2,666.0 psf Wall height above soil 0.00 ft Equivalent Fluid Pressure Method Active Heel Pressure 45.0 psfIft Slope Behind Wall 0.00 Height of Soil over Toe 8.00 in Water height over heel 0.0 ft Passive Pressure 300.0 psf/ft Surcharge Loads Surcharge Over Heel 0.0 psf Used To Resist Sliding & Overturning Surcharge Over Toe 0.0 Used for Sliding & Overturning Axial Load Applied to Stem____Jll Axial Dead Load 0.0 lbs Axial Live Load 0.0 lbs Axial Load Eccentricity 0.0 in Earth Pressure Seismic Load---J Method : Uniform Multiplier Used 7.000 (Multiplier used on soil density) Design Summary Wall Stability Ratios Overturning 1.36 Ratio < Sliding 1.31 Ratio < Total Bearing Load 1,811 lbs ... resultant ecc. 13.40 in Soil Pressure @ Toe 2,197 psf OK Soil Pressure @ Heel 0 psf OK Allowable 2,666 psf Soil Pressure Less Than Allowable ACI Factored @ Toe 3,076 psf ACI Factored @ Heel 0 psf Footing Shear @ Toe 27.9 psi OK Footing Shear @ Heel 9.3 psi OK Allowable 75.0 psi Sliding Cates Lateral Sliding Force 1, 157.4 lbs less 100% Passive Force 704.2 lbs less 100% Friction Force 815.2 lbs Added Force Req'd 0.0 lbs OK .... for 1.5 Stability 216.8 lbs NG Soil Density, Heel = 110.00 pef Soil Density, Toe = 110.00 pcf FootingflSoil Friction 0.450 Soil height to ignore for passive pressure 0.00 in [�L�ateral Load Applied to Stem -A Lateral Load 0.0 #/ft ... Height to Top 0.00 ft ... Height to Bottom 0.00 ft Load Type = Wind (W) (Service Level) Wind on Exposed Stem = 0.0 psf (Service Level) Uniform Seismic Force = 45.495 Total Seismic Force = 295.689 Stem Construction 11- Design Height Above Ftg ft 1.5! Wall Material Above "Ht" 1.5! n-; � rA.fh-j V Thickness Rebar Size Rebar Spacing Rebar Placed at Design Data fb/FB + fa/Fa Total Force @ Section Service Level lbs = Strength Level lbs = Moment .... Actual Service Level ft-# = Strength Level ft-# = Moment ..... Allowable Shear ..... Actual Service Level psi = Strength Level psi = Shear ..... Allowable psi = Anet (Masonry) in2 = Rebar Depth 'd' in= Masonry Data fm psi = Fs psi = Solid Groutino Vertical component of active lateral soil pressure IS Modular Ratio 'n' considered in the calculation of soil bearing pressures. 1A1 11 VAI ; k f Load Factors - po Building Code Dead Load 6=0 Live Load Earth, H 111111111 Wind, W Seismic, E IBC 2015,ACI 1.200 1.600 1.600 1.000 1.000 a eg L ps Short Term Factor Bottom Adjacent Footing Load Adjacent Footing Load 0.0 lbs Footing Width 0.00 ft Eccentricky 0.00 in Wail to Fig CL Dist 0.00 ft Footing Type Line Load Base Above/Below Soil at Back of Wall 0-0 ft Poisson's Ratio 0.300 Concrete LRFD LRFD LRFD 8.00 4 10.00 5.75 i 0,493 1,413.5 2,913.1 5,904.1 20.5 75.0 5.75 100.0 Equiv. Solid I hick. Masonry Block Type = Medium Weight Masonry Design Method = ASD Concrete Data fc psi = 2,500.0 Fy psi = 60,000.0 1987-2017, Build 11.17.07.2T .06057724 Cantilevered Retaining Wall SOUND STRUCTURAL SOLUTIONS. INC W bm Am kow Code: IBC 2015ACI 318-14,ACI 530-13 OR 00 Concrete Stem Rebar Area Details Bottom Stem Vertical Reinforcing Horizontal Reinforcing As (based on applied moment): 0. 1192 in2/ft (4/3) * As : 0. 1589 in2/ft Min Stem T&S Reinf Area 1.088 in2 200bd/fy: 200(12)(5.75)/60000: 0.23 in2/ft Min Stem T&S Reinf Area per ft of stem Height: 0.192 in2/ft 0.0012bh : 0.0012(12)(8): 0. 1152 in2/ft Horizontal Reinforcing Options : One layer of: Two layers of: Required Area 0. 1589 in2/ft #4@ 12.50 in #4@ 25.00 in Provided Area 0.24 in2/ft #5@ 19.38 in #5@ 38.75 in Maximum Area: 0.7789 in2/ft #6@ 27.50 in #6@ 55.00 in Footing Dimensions & Strengths Footing Design Results Toe Width 1.67 ft Toe Heel Heel Width 1.67 Factored Pressure 3,076 0 psf Total Footing Width 3.33 Mu': Upward 2,831 0 ft-# Footing Thickness 10.00 in Mu': Downward 330 448 ft-# Mu: Design 2,501 448 ft-# Key Width 10.00 in Actual I -Way Shear = 27.87 9.35 psi Key Depth 8.00 in Allow 1-Way Shear = 75.00 40.00 psi Key Distance from Toe 0.00 It Toe Reinforcing = # 4 @ 10.00 in fc = 2,500psi Fy 60'�000 psi Heel Reinforcing = None Spec'd Footing Concrete Density 150.00pcf Key Reinforcing = None Spec'd Min. As % 0.0018 Other Acceptable Sizes & Spacings Cover @ Top 2.00 @ Btm.= 3.50 in Toe: #4@ 11.11 in, #5@ 17.22 in, #6@ 24.44 in, #7@ 33.33 in, #8@ 43.89 in, #9@ 5 Heel: Not req'd: Mu < phi*5*lambda*sqrt(fc)*Sm Key: Not req'd: Mu < phi*5*lambda*sqrt(fc)*Sm Min footing T&S reinf Area 0.80 in2 Min footing T&S reinf Area per foot 0.24 in2 A If one layer of horizontal bars: If two layers of horizontal bars: #4@ 10.00 in #4@ 20.00 in #5@ 15.50 in #5@ 31.00 in #6@ 22.00 in #6@ 44.00 in Summary of Overturning & Resisting Forces & Moments '**"' OVERTURNING ..... ..... RESISTING ..... Force Distance Moment Force Distance Moment Item lbs ft ft-# lbs It ft-# Heel Active Pressure 950.4 2.17 2,059.1 Soil Over Heel 622.8 2.83 1,764.1 Surcharge over Heel Sloped Soil Over Heel Surcharge Over Toe Surcharge Over Heel Adjacent Footing Load Adjacent Footing Load = Added Lateral Load Axial Dead Load on Stem = Load @ Stem Above Soil Axial Live Load on Stem = Seismic Earth Load 207.0 3.25 672.6 Soil Over Toe 122.2 0.83 101.8 Surcharge Over Toe Total 1,157.4 O.T.M. 2,731.7 Stem Weight(s) 566.6 2.00 1,132.8 Earth @ Stem Transitions Footing Weight 416�5 1.67 693.9 Resisting/Overturning Ratio 1.36 Key Weight 83.3 0.42 34.7 Vertical Loads used for Soil Pressure 1,811.5 lbs Vert. Component 3.33 Total 1,811.5 lbs R.M.= 3,727.3 If seismic is included, the OTM and sliding ratios Axial live load NOT included in total displayed, or used for overturning be 1.1 per section 1807.2.3 of IBC 20D9 or IBC 201 resistance, but is included for soil pressure calculation. Vertical component of active lateral soil pressure IS considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS considered in the calculation of Overturning Resistance. on b.w bud b.W M bow 1=0 a we P0 IEW W MW RetaliriPro(c)1987-2017, Build 11.17.07.27 License: KW-06057724 Cantilevered Retaining Wall License To: SOUND STRUCTURAL SOLUTIONS, INC 11 Horizontal Deflection at Top of Wall due to settlement Of S'Dil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 250.0 pci Horizontal Defl @ Top of Wall (approximate only) 0.104 in The above calculation is not valid if the heel soil bearing p[e§�sLjpLq�iceeds that of the toe because the wall would then tend to rotate into the retained soil. Code: IBC 2015ACI 318-14,ACI 530-13 No NMI 7, Build 11.17.07.27 Cantilevered Retaining Wall I I STRUCTUP-AL SOLUTIONS. INC Criteria mmm"767 ft Soil Data I Retained Height Allow Soil Bearing 2,000.0 psf Wall height above soil 0.00 ft Equivalent Fluid Pressure Method Slope Behind Wall 0.00 Active Heel Pressure 45.0 psfIft Height of Soil over Toe 8.00 in on Code: IBC 2015ACI 318-14,ACI 530-13 Water height over heel 0.0 ft Passive Pressure 300.0 psf1ft Soil Density, Heel = 110.00 pcf Soil Density, Toe = 110.00 pcf FootingIlSoil Friction 0.450 Soil height to ignore for passive pressure 0.00 in Surcharge Loads ateral Load Applied to Stem [Adjacent Footing Load Surcharge Over Heel 0.0 psf Lateral Load 0.0 #/ft Adjacent Footing Load 0.0 lbs Used To Resist Sliding & Overturning ... Height to Top 0.00 ft Footing Width 0.00 ft Surcharge Over Toe 0.0 ... Height to Bottom 0.00 ft Eccentricity 0.00 in Used for Sliding & Overturning Load Type = Wind (W) Wall to Ftg CL Dist 0.00 ft Axial Load Applied to Ste (Service Level) Footing Type Line Load Base Above/Below Soil 0.0 ft Axial Dead Load 0.0 lbs Wind on Exposed Stem = 0.0 Psf at Back of Wall Axial Live Load 0.0 lbs (Service Level) Poisson's Ratio 0.300 Axial Load Eccentricity 0.0 in � Design Summary Wall Stability Ratios Overturning 1.81 OK Sliding 1.60 OK Total Bearing Load 1,811 lbs ... resultant ecc. 8,94 in Soil Pressure @ Toe 1,311 psf OK Soil Pressure @ Heel 0 psf OK Allowable 2,000 psf Soil Pressure Less Than Allowable ACI Factored @ Toe 1,836 psf ACI Factored @ Heel 0 psf Footing Shear @ Toe 19.1 psi OK Footing Shear @ Heel 8.7 psi OK Allowable 75.0 psi Sliding CaIcs Lateral Sliding Force 950.4 lbs less 100% Passive Force 704.2 lbs less 100% Friction Force 815.2 lbs Added Force Req'd 0.0 lbs OK .... for 1.5 Stability 0.0 lbs OK Vertical component of active lateral soil pressure IS considered in the calculation of soil bearing pressures. Load Factors - Building Code Dead Load Live Load Earth, H Wind, W Seismic, E IBC 2015,ACI 1.200 1.600 1.600 1.000 1.000 Stem Const uction Bottom Stem OK Design Height Above Ftg ft = 0.00 Wall Material Above "Ht" = Concrete Design Method LRFD Thickness 8.00 Rebar Size # 4 Rebar Spacing 10.00 Rebar Placed at 5.75 i Design Data fb/FB + fa/Fa 0.370 Total Force @ Section Service Level lbs = Strength Level lbs = 1,155.7 Moment .... Actual Service Level ft-# = Strength Level ft-# = 2,1182.19 Moment ..... Allowable = 5,904.1 Shear ..... Actual Service Level psi = Strength Level psi = 16.7 Shear ..... Allowable psi = 75.0 Anet (Masonry) in2 = Rebar Depth 'd' in= 5.75 Masonry Data fm psi = Fs psi = Solid Grouting Modular Ratio'n' Wall Weight psf 100.0 Short Term Factor Equiv. Solid Thick. Masonry Block Type = Medium V Masonry Design Method = ASO Concrete Data fc psi = 2,500,0 Fy psi = 60,000.0 eight LRFD LRFD ow FAI M1 111M wo we 0" pa to .00 Its 7 b.W RetainPro(c)1987-2017, Build 11.17.07.27 License : KW-06057724 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13 License To: SOUND STRUCTURAL SOLUTIONS, INC Concrete Stem Rebar Area Details Bottom Stem Vertical Reinforcing Horizontal Reinforcing As (based on applied moment): 0.0893 in2/ft (4/13) * As : 0.1191 in2/ft Min Stem T&S Reinf Area 1.088 in2 200bd/fy: 200(12)(5.75)/60000: 0.23 in2/ft Min Stem T&S Reinf Area per ft of stem Height: 0.192 in2/ft 0.0012bh : 0.0012(12)(8): 0. 1152 in2/ft Horizontal Reinforcing Options : One layer of: Two layers of Required Area 0.1191 in2/ft #4@ 12.50 in #4@ 25.00 in Provided Area 0.24 in2/ft #5@ 19.38 in #5@ 38.75 in Maximum Area: 0.7789 in2/ft #6@ 27.50 in #6@ 55.00 in Footing Dimensions & Str�engths Footing Design Results Toe Width 1.67 ft Toe Heel Heel Width 1.67 Factored Pressure 1,836 0 psf Total Footing Width 3.33 Mu': Upward 2,036 9 ft-# Footing Thickness 10.00 in Mu': Downward 330 448 ft-# Mu: Design 1,705 440 ft-# Key Width Key Depth 10.00 in Actual 1 -Way Shear 8.00 in = 19.13 8.71 psi Key Distance from Toe Allow 1-Way Shear 0.00 ft = 75.00 40.00 psi Toe Reinforcing = # 4 @ 10.00 in fc = 2,500 psi Fy 60,000 psi Heel Reinforcing = None Spec'd Footing Concrete Density = 150.00pcf Key Reinforcing = None Spec'd Min. As % 0.0018 Other Acceptable Sizes & Spacings Cover @ Top 2.00 @ Btm.= 3.50 in Toe: #4@ 11. 11 in, #5@ 17.22 in, #6@ 24.44 in, #7@ 33.33 in, #8@ 43.89 in, #9@ 5 Heel: Not req'd: Mu < phi*5*lambda*sqrt(fc)*Sm Key: Not req'd: Mu < phi*5*lambda*sqrt(fc)*Sm Min footing T&S reinf Area 0.80 in2 Min footing T&S reinf Area per foot 0.24 in2 A If one layer of horizontal bars: If two layers of horizontal bars: #4@ 10.00 in #4@ 20.00 in #5@ 15.50 in #5@ 31.00 im #6@ 22.00 in #6@ 44.00 in Summa of Overturning & Resisting Forces & Moments. ..... OVERTURNING ..... ..... RESISTING ..... Force Distance Moment Force Distance Moment Item lbs ft ft-# lbs ft ft-# Heel Active Pressure Surcharge over Heel Surcharge Over Toe Adjacent Footing Load Added Lateral Load Load @ Stem Above Soil Total 950.4 2.17 950A O.T.M 2,059.1 Soil Over Heel Sloped Soil Over Heel Surcharge Over Heel Adjacent Footing Load = Axial Dead Load on Stem = Axial Live Load on Stem = Soil Over Toe Surcharge Over Toe 2,059.1 Stem Weight(s) Earth @ Stem Transitions Res isti ng/Overturning Ratio 1.81 Vertical Loads used for Soil Pressure 1,811.5 lbs Vertical component of active lateral soil pressure IS considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS considered in the calculation of Overturning Resistance. 622.8 2.83 122.2 0.83 566.6 2.00 1,764.1 101.8 1,132.8 Footing Weight 416.5 1.67 693.9 Key Weight 83.3 0.42 34.-o Vert. Component 3.33 Total 1,811.5 lbs R.M.� 3,727.3 Axial live load NOT included in total displayed, or used for overturning resistance, but is included for soil pressure calculation. W Im RetainPro(c)1987-2017, Build 11.17.07.27 MR License: KW-06057724 Cantilevered Retaining Wall Code: 113C 2015ACI 318-14,ACI 530-13 License To: SOUND STRUCTURAL SOLUTIONS, INC Tilt I Horizontal Deflection at Top of Wall due to settlement of soil (Deflection due to wall bending not considered) VON Soil Spring Reaction Modulus 250.0 pci 104 Horizontal Defl @ Top of Wall (approximate only) 0.062 in The above calculation is not valid if the heel soil bearin.Q-L)Ef�ssure exceeds that of the toe, because the wall would then tend to rotate into the retained soil. 04 am bw bw Pq No 11011 ow am an FM hmL on om (AI 6M rl RetainPro (c) 1987-2017, Build 11.17.07.27 License : KW-06057724 Cantilevered Retaining Wall Code: IBC 2015ACI 318-14ACI 530-13 License To: SOUND STRUCTURAL SOLUTIONS, INC [criteria Retained Height 4.67 ft Allow Soil Bearing 2,666.0 psf I Wall height above soil 0.00 ft Equivalent Fluid Pressure Method Active Heel Pressure 45.0 psf1ft Slope Behind Wall 0.00 Height of Soil over Toe 8.00 in Water height over heel 0.0 ft Passive Pressure 300.0 psf/ft Surcharge Loads Surcharge Over Heel o.o psf Used To Resist Sliding & Overturning Surcharge Over Toe 0.0 Used for Sliding & Overturning lal Load Applied to Stem Axial Dead Load 0.0 lbs Axial Live Load 0.0 lbs Axial Load Eccentricity 0.0 in Earth Pressure Seismic L Method : Uniform Multiplier Used 7.000 (Multiplier used on soil density) Design Summary Wall Stability Ratios Soil Density, Heel = 110.00 pGf Soil Density, Toe = 110.00 pcf FootingIlSoil Friction 0.450 Soil height to ignore for passive pressure 0.00 in Lateral Load Applied to Stem­--j Lateral Load 0.0 #/ft ... Height to Top 0.00 ft ... Height to Bottom 0.00 ft Load Type Wind (W) (Service Level) Wind on Exposed Stem 0,0 Psf (Service Level) Uniform Seismic Force = 38.495 Total Seismic Force = 211,699 [St-e-mConstruction .1 - Design Height Above Ftg ft = Overturning 1.92 OK Wall Material Above "Ht" Sliding 1.23 Ratio < 1.5! Design Method Total Bearing Load 1,518 lbs ... resultant ecc. 7.93 in Soil Pressure @ Toe 1,007 psf OK Soil Pressure @ Heel 0 psf OK Allowable 2,666 psf Soil Pressure Less Than Allowable ACI Factored @ Toe 1,409 psf ACI Factored @ Heel 0 psf Footing Shear @ Toe 10.6 psi OK Footing Shear @ Heel 6.8 psi OK Allowable 75.0 psi Sliding CaIcs Lateral Sliding Force 828.6 lbs less 100% Passive Force = 337.5 lbs less 100% Friction Force = 683.2 lbs Added Force Req'd 0.0 lbs OK .... for 1.5 Stability 222.3 lbs NG Thickness Rebar Size Rebar Spacing Rebar Placed at Design Data fb/FB + fa/Fa Total Force @ Section Service Level lbs = Strength Level lbs = Moment .... Actual Service Level ft-# = Strength Level ft-# = Moment ..... Allowable Shear ..... Actual Service Level psi = Strength Level psi = Shear ..... Allowable psi = Anet (Masonry) in2 = Rebar Depth 'd' in = Masonry Data - fm psi = Fs psi = Solid Groutina Vertical component of active lateral soil pressure IS Modular Ratio 'n' considered in the calculation of soil bearing pressures. XA1 11 1A1 : Load Factors - Building Code Dead Load Live Load Earth, H Wind, W Seismic, E IBC 2015,ACI 1.200 1.600 1.600 1.000 1.000 a e gHt PSI Short Term Factor Bottom icent Footinq Load Aajacent i--ooung LOaCl U.0 Ib Footing Width 0.00 ft Eccentricity 0.00 in Wall to Ftg CL Dist 0.00 ft Footing Type Line Load Base Above/Below Soil at Back of Wall 0.0 ft Poisson's Ratio 0.300 Stem OK 0.00 Concrete LRFD LRFD LRFD 8.00 # 4 16.00 5.75 i 0.435 963.4 1,638.1 3,761.8 14.0 75.0 5.75 100.0 MqUIV. 0011U I HICK. Masonry Block Type = Medium Weight Masonry Design Method = ASO Concrete Data fc psi = 2,500.0 Fy psi = 60,000.0 RetainPro (c) 1987-2017, Build 11.17.07.27 License: KW-06057724 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13 License To: SOUND STRUCTURAL SOLUTIONS, INC Concrete Stem Rebar Area Details Bottom Stem Vertical Reinforcing Horizontal Reinforcing As (based on applied moment): 0.067 in2/ft (4/3) * As : 0,0894 in2/ft Min Stem T&S Reinf Area 0.896 in2 200bd/fy 200(12)(5.75)/60000 0.23 in2/ft Min Stem T&S Reinf Area per ft of stem Height: 0.192 in2/ft 0,0012bh 0.0012(12)(8): 0. 1152 in2/ft Horizontal Reinforcing Options : One layer of : Two layers of Required Area 0. 1152 in2/ft #4@ 12 50 in #4@ 25.00 in Provided Area 0. 15 in2/ft #5@ 19.38 in #5@ 38.75 in Maximum Area: 0.7789 in2/ft #6@ 27.50 in #6@ 55.00 in Footing Dimensions & Strengths Footing Design Results Toe Width 1.67 ft Toe Heel Heel Width 1.67 Factored Pressure T409 0 psf Total Footing Width 3.33 Mu': Upward 1,596 25 ft-# Footing Thickness 10.00 in Mu': Downward 330 382 ft-# Mu: Design 1,265 358 ft-# Key Width 10.00 in Actual 1 -Way Shear = 10.56 6.84 psi Key Depth 0.00 in Allow 1 -Way Shear = 40.00 40.00 psi Key Distance from Toe 0.00 ft Toe Reinforcing = # 4 @ 16.00 in fc = 2,500psi Fy 60,,000 psi Heel Reinforcing = None Spec'd Footing Concrete Density 150.00 pcf Key Reinforcing = None Spec'd Min. As % 0.0018 Other Acceptable Sizes & Spacings Cover @ Top 2.00 @ Btm.= 3.50 in Toe: #4@ 11.11 in, #5@ 17.22 in, #6@ 24.44 in, #7@ 33.33 in, #8@ 43.89 in, #9@ 5 Heel: Not req'd: Mu < phi*5*lambda*sqrt(fc)*Sm Key: Not req'd: Mu < ph i*5* lam bda*sqrt(fc)*Sm Min footing T&S reinf Area 0.80 in2 Min footing T&S reinf Area per foot 0.24 in2 /ft If one layer of horizontal bars: If two layers of horizontal bars: #4@ 10.00 in #4@ 20.00 in #5@ 15.50 in #5@ 31.00 in #6@ 22.00 in #6@ 44.00 in Summary of Overturning & Resisting Forces & Moments ...... OVERTURNING .... ..... RESISTING .... Force: Distance 6ment Force Distance Moment Item lbs ft ft-# lbs ft ft-# Heel Active Pressure 680.5 1.83 1,247.4 Soil Over Heel 512.9 2.83 1,452.8 Surcharge over Heel Sloped Soil Over Heel Surcharge Over Toe Surcharge Over Heel Adjacent Footing Load Adjacent Footing Load = Added Lateral Load Axial Dead Load on Stem = Load @ Stem Above Soil Axial Live Load on Stem = Seismic Earth Load 148.2 2.75 407.5 Soil Over Toe 122.2 0.83 101.8 Surcharge Over Toe Total 828 6 O.T.M. 1,654.8 Stem Weight(s) 466.6 2.00 932.9 Earth @ Stem Transitions Footing Weight 416.5 1.67 693.9 Resisting/Overtunning Ratio 1.92 Key Weight 0.42 Vertical Loads used for Soil Pressure 1,518.2 lbs Vert. Component 3.33 Total 1,518.2 lbs R.M.� 3,181.3 If seismic is included, the OTM and sliding ratios be 1.1 per section 1807.2.3 of I BC 2009 or I BC 201 Vertical component of active lateral soil pressure IS considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS considered in the calculation of Overturning Resistance. Axial live load NOT included in total displayed, or used for overturning resistance, but is included for soil pressure calculation. tow P4 I low PIN %-W RetainPro (c) 1987-2017, Build 11.17.07.27 L�cense: KW-06057724 Cantilevered Retaining Wall Code: IBC 2015ACI 318-14,ACI 530-13 how license To: SOUND STRUCTURAL SOLUTIONS, INC F-Illt Pq Horizontal Deflection at Top of Wall due to settlement of soil 61� (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 250.0 pci Horizontal Defl @ Top of Wall (approximate only) 0.039 in The above calculation is not valid if the heel soil bearLQ_q_pl!��sure exceeds that of the toe, because the wall would then tend to rotate into the retained soil. RetainPro (c) 1987-2017, Build 11.17.07.27 License : KW-06057724 Cantilevered Retaining Wall Code: IBC 2015ACI 318-14,ACI 530-13 License To: SOUND STRUCTURAL SOLUTIONS, INC Criteria Soil Data Retained Height m��4.67ft Allow Soil Bearing 2,000.0 psf Wall height above soil 0.00 ft Equivalent Fluid Pressure Method Active Heel Pressure 45.0 psf/ft Slope Behind Wall 0.00 Height of Soil over Toe 8.00 in Water height over heel = 0.0 ft Surcharge Loads Surcharge Over Heel 0.0 psf Used To Resist Sliding & Overturning Surcharge Over Toe 0.0 Used for Sliding & Overturning Axial Load Applied to Stem� Axial Dead Load 0.0 lbs Axial Live Load 0.0 lbs Axial Load Eccentricity 0.0 in Design -summary Wall Stability Ratios Overturning 2.55 OK Sliding 1 50 OK Total Bearing Load 1,519 lbs ... resultant ecc. 4.70 in Soil Pressure @ Toe T77 psf OK Soil Pressure @ Heel 134 psf OK Allowable 2,000 psf Soil Pressure Less Than Allowable ACI Factored @ Toe 1,088 psf ACI Factored @ Heel T88 psf Footing Shear @ Toe 8.1 psi OK Footing Shear @ Heel 4.6 psi OK Allowable 75.0 psi Sliding CaIcs Lateral Sliding Force 680.5 lbs less 100% Passive Force 33-7.5 lbs less 100% Friction Force 683.5 lbs Added Force Req'd 0.0 lbs OK .... for 1.5 Stability 0.0 lbs OK Vertical component of active lateral sal pressure IS considered in the calculation of soil bearing pressures. Load Factors - Building Code Dead Load Live Load Earth, H Wind, W Seismic, E IBC 2015,ACI 1.200 1.600 1.600 1.000 1.000 Passive Pressure 300.0 psfIft Soil Density, Heel = 110.00 pcf Soil Density, Toe = 110.00 pcf FootingIlSoil Friction 0.450 Soil height to ignore for passive pressure 0.00 in 11ateral Load Applied to Stem Lateral Load 0.0 47. ... Height to Top 0.00 ft ...Height to Bottom 0.00 ft Load Type = Wind (W) (Service Level) Wind on Exposed Stem = 0.0 psf (Service Level) Adjacent Footing Load Adjacent Footing Load 0.0 lbs Footing Width 0.00 ft Eccentricity 0.00 in Wall to Ftg CL Dist 0.00 ft Footing Type Line Load Base Above/Below Soil at Back of Wall 0.0 ft Poisson's Ratio 0.300 r-stem constr� Bottom St rn 0, e Design Height Above Ftg ft = 0.00 Wall Material Above "Ht" = Concrete Design Method LRFD Thickness 8.00 Rebar Size # 4 Rebar Spacing 16.00 Rebar Placed at 5.75 i Design Data fb/FB + fa/Fa 0.324 Total Force @ Section Service Level lbs = Strength Level lbs = 783.8 Moment .... Actual Service Level ft-# = Strength Level ft-# = 1,219.0 Moment ..... Allowable = 3,761.8 Shear ..... Actual Service Level psi = Strength Level psi = 11.4 Shear ..... Allowable psi = 75.0 Anet (Masonry) in2 = Rebar Depth 'd' in= 5.75 Masonry Data fm psi = Fs psi = Solid Grouting Modular Ratio'n' Wall Weight psf 100.0 Short Term Factor Equiv. Solid Thick. Masonry Block Type = Medium V Masonry Design Method = ASD Concrete Data fc psi = 2,500.0 Fy psi = 60,000.0 eight P" aw 044 No PIN wo No imm on No INN pe a* on Im ow I" WW r Will 6�. had RetainPro (c) 1987-2017, Build 11.17.07.27 License: KW-06057724 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13 License To: SOUND STRUCTURAL SOLUTIONS, INC Concrete Stem Rebar Area Details Bottom Stem Vertical Reinforcing Horizontal Reinforcing As (based on applied moment): 6.0499 in2/ft (4/3) * As : 0.0665 in2/ft Min Stem T&S Reinf Area 0.896 in2 200bd/fy: 200(12)(5.75)/60000: 0.23 in2/ft Min Stem T&S Reinf Area per ft of %tem Height: 0.192 in2/ft 0.0012bh : 0.0012(12)(8): 0. 1152 in2/ft Horizontal Reinforcing Options: One layer of : Two layers of Required Area 0. 1152 in2/ft #4@ 12.50 in #4@ 25.00 in Provided Area 0. 15 in2/ft #5@ 19.38 in #5@ 38.75 in Maximum Area: 0.7789 in2/ft #6@ 27.50 in #6@ 55.00 in Footing Dimensions & Strengths F -Footing Design Results ----- Toe Width 1.67 ft Toe Heel Heel Width 1.67 Factored Pressure 1,088 188 psf Total Footing Width 3.33 Mu': Upward 1,302 139 ft-# Footing Thickness 10.00 in Mu': Downward 330 383 ft-# Mu: Design 971 244 ft-# Key Width Key Depth 10.00 in Actual I -Way Shear = 8.05 4.61 psi 0.00 in Key Distance from Toe Allow 1-Way Shear = 40.00 40,00 psi 0.00 ft Toe Reinforcing = # 4 @ 16.00 in fc = 2,500 psi Fy 60,000 psi Heel Reinforcing = None Spec'd Footing Concrete Density 150.00pcf Key Reinforcing = None Spec'd Min. As % 0.0018 Other Acceptable Sizes & Spacings Cover @ Top 2.00 @ Btm.= 3.50 in Toe: #4@ 11.11 in, #5@ 17.22 in, #6@ 24.44 in, #7@ 33.33 in, #8@ 43.89 in, #9@ 5 Heel: Not req'd: Mu < phi*5*lambda*sqrt(fc)*Sm Key: Not req'd: Mu < phi*5*lambda*sqrt(fc)*Sm Min footing T&S reinf Area 0.80 in2 Min footing T&S reinf Area per foot 0.24 in2 A If one layer of horizontal bars: If two layers of horizontal bars: #4@ 10.00 in #4@ 20.00 in #5@ 15.50 in #5@ 31.00 in #6@ 22.00 in #6@ 44.00 in Summary of Overturning & Resisting Forces & Moments Itam F­* _­­ _­..­_--..�oment orce Distance lbs ft ft-# Heel Active Pressure 680.5 1.83 1,247.4 Surcharge over Heel Surcharge Over Toe Adjacent Footing Load Added Lateral Load Load @ Stem Above Soil Total 680.5 O.T.M. 1,247.4 Resisting/Overturning Ratio 2.55 Vertical Loads used for Soil Pressure 1,518.8 lbs Vertical component of active lateral soil pressure IS considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS considered in the calculation of Overturning Resistance. ..... RESISTING ..... Force Distance Moment lbs ft ft-# Soil Over Heel 513.4 2.83 1,454.5 Sloped Soil Over Heel Surcharge Over Heel Adjacent Footing Load = Axial Dead Load on Stem = Axial Live Load on Stem = Soil Over Toe 122.2 0.83 1011.8 Surcharge Over Toe Stem Weight(s) 466.6 2.00 932.9 Earth @ Stem Transitions Footing Weight 416.6 1.67 694.3 Key Weight 0.42 Vert. Component 3.33 Total 1,518.8 lbs R.M.= 3,183A Axial live load NOT included in total displayed, or used for overturning resistance, but is included for soil pressure calculation. No fto RetainPro(c)1987-2017, Build 11.17.07.27 License : KW-06057724 Cantilevered Retaining Wall P" Code: IBC 2015ACI 318-14ACI 530-13 License To: SOUND STRUCTURAL SOLUTIONS, INC Tilt Horizontal Deflection at Top of Wall due to settlement of soil (Deflection due to wall bencling not considered) Soil Spring Reaction Modulus 250.0 pci P" Horizontal DO @ Top of Wall (approximate only) 0.030 in The above calculation is not valid if the heel soil bearinq_pLes��u(Lgxceeds that of the toe Wv because the wall would then tend to rotate into the retained soil. lka Ow PIN no 11M No ON Ow Not ind Pit ' r" 1-d )AIW Reta!nPro(c)1987-2017, Build 11.17.07.27 License: KW-06057724 Cantilevered Retaining Wall Code: IBC 2015ACI 318-14,ACI 530-13 License To: SOUND STRUCTURAL SOLUTIONS, INC Criteria Soil Data Retained Height 3.67 ft Allow Soil Bearing 2,666.0 psf Wall height above soil 0.00 ft Equivalent Fluid Pressure Method Active Heel Pressure 45.0 psfIft Slope Behind Wall 0.00 Height of Soil over Toe 8.00 in Water height over heel 0.0 ft Passive Pressure 300.0 psf/ft Surcharge Loads Surcharge Over Heel 0,0 psf Used To Resist Sliding & Overturning Surcharge Over Toe 0.0 Used for Sliding & Overturning Axial Load Applied to Stem::7]111 Axial Dead Load 0.0 lbs Axial Live Load 0.0 lbs Axial Load Eccentricity 0.0 in Earth Pressure Seismic Load Method : Uniform Multiplier Used 7.000 (Multiplier used on soil density) Design Summary Wall Stability Ratios Soil Density, Heel = 110.00 PCf Soil Density, Toe = 110.00 pcf FootingIlSoil Friction 0.450 Soil height to ignore for passive pressure 0.00 in Lateral Load Applied to St I Adjacent Footing Load Lateral Load 0.0 #/ft Adjacent Footing Load 0.0 lb ... Height to Top 0.00 ft Footing Width 0.00 ft ... Height to Bottom 0.00 ft Eccentricity 0.00 in Load Type = Wind (W) Wall to Fig CL Dist 0.00 ft (Service Level) Footing Type Line Load Base Above/Below Soil 0.0 ft Wind on Exposed Stem = 0.0 psf at Back of Wall (Service Level) Poisson's Ratio 0.300 Uniform Seismic Force = 31.495 Total Seismic Force = 141.708 �Construction Design Height Above Ftg ft Overturning = 1.93 OK Wall Material Above "Ht" Sliding 1.47 Ratio < 1.5! Design Method Thickness Total Bearing Load 1,066 lbs Rebar Size ... resultant ecc. 6.53 in Rebar Spacing Soil Pressure @ Toe 902 psf OK Rebar Placed at Design Data Soil Pressure @ Heel 0 psf OK fb/FB + fa/Fa Allowable 2,666 psf Total Force @ Section Soil Pressure Less Than Allowable ACI Factored @ Toe 1,262 psf Service Level lbs = ACI Factored @ Heel 0 psf Strength Level lbs = Footing Shear @ Toe 6.7 psi OK Moment .... Actual Footing Shear @ Heel 4.0 psi OK Service Level ft-# = Allowable 75.0 psi Strength Level ft-# = Sliding CaIcs Moment ..... Allowable Lateral Sliding Force 554.7 lbs Shear ..... Actual less 100% Passive Force = 337.5 lbs Service Level psi = less 100% Friction Force = 479.8 lbs Strength Level psi = Added Force Req'd 0.0 lbs OK Shear ..... Allowable psi = .... for 1.5 Stability 14.7 lbs NG Anet (Masonry) in2 = Rebar Depth 'd' in = Masonry Data fm psi = Fs psi = Solid Grouting Vertical component of active lateral soil pressure IS Modular Ratio'n' considered in the calculation of soil bearing pressures. 1A1 11 1A1 ; kf 4! Load Factors - Building Code Dead Load Live Load Earth, H Wind, W Seismic, E IBC 2015,ACI 1.200 1.600 1.600 1.000 1.000 . . V ps Short Term Factor C : 0 Bottom Stem OK 0.00 Concrete LRFD LRFD LRFD 8.00 # 4 16.00 5.75 i 0.213 599.3 802.9 3,761.8 8.7 75.0 5.75 100.0 qu v. olid I hick. Masonry Block Type = Medium Weight Masonry Design Method = ASD Concrete Data fc psi = 2,500.0 Fy psi = 60,000.0 RetainPro (c) 1987-2017, Build 11.17.07.27 License : KW-06057724 Cantilevered Retaining Wall Code: IBC 2015ACI 318-14,ACI 530-13 License To: SOUND STRUCTURAL SOLUTIONS, INC Concrete Stem Rebar Area Details Bottom Stem Vertical Reinforcing Horizontal Reinforcing As (based on applied moment): 0.0329 in2/ft (4/3) * As: 0.0438 in2/ft Min Stem T&S Reinf Area 0.880 in2 200bd/fy: 200(12)(5.75)/60000: 0.23 in2/ft Min Stem T&S Reinf Area perft of stem Height: 0.240 in2/ft 0.0012bh : 0.0012(12)(8): 0. 1152 in2/ft Horizontal Reinforcing Options: One layer of: Two layers of: Required Area 0. 1152 in2/ft #4@ 10.00 in #4@ 20.00 in Provided Area 0.15 in2/ft #5@ 15.50 in #5@ 31.00 in Maximum Area: 0.7789 in2/ft #6@ 22.00 in #6@ 44.00 in Footing Dimensions & Strengths Footing Design Results M I Toe Width - 1.33 ft Toe Heel Heel Width - 1.33 Factored Pressure T,262 0 psf Total Footing Width 2.67 Mu': Upward 911 4 ft­# Footing Thickness 10.00 in Mu': Downward 211 141 ft­# Mu: Design 699 136 ft-# Key Width 0.00 in Actual 1-Way Shear = 6.70 4.03 psi Key Depth 0.00 in Allow 1 -Way Shear = 40.00 40.00 psi Key Distance from Toe 0.00 ft Toe Reinforcing = None Spec'd fc = 2,500psi Fy = 60,000 psi Heel Reinforcing = None Spec'd Footing Concrete Density 15D.Oopcf Key Reinforcing = None Spec'd Min. As % 0.0018 Other Acceptable Sizes & Spacings Cover @ Top 2.00 @ Btm.= 3.50 in Toe: #4@ 11.11 in, #5@ 17.22 in, #6@ 24.44 in, #7@ 33.33 in, #8@ 43.89 �n, #9@ 5 Heel: Not req'd: Mu < phi*5*lambda*sqrt(fc)*Sm Key: No key defined Min footing T&S reinf Area 0.64 in2 Min footing T&S reinf Area per foot 0.24 in2 /ft If one layer of horizontal bars: If two layers of horizontal bars: #4@ 10.00 in #4@ 20.00 in #5@ 15.50 in #5@ 31.00 in #6@ 22.00 in #6@ 44.00 in Summa of Overturning & Resisting Forces & Moments ...... OVERTURNING .... ..... RESISTING ..... Force Distance �oment Force Distance Moment Item lbs ft ft-# lbs ft ft-# Heel Active Pressure Surcharge over Heel Surcharge Over Toe Adjacent Footing Load Added Lateral Load Load @ Stem Above Soil Seismic Earth Load 455.5 1.50 683.1 99.2 2.25 223.2 Total 554.7 O.T.M. 906.3 Resisting/Overtunning Ratio 1.93 Vertical Loads used for Soil Pressure 1,066.3 lbs If seismic is included, the OTM and sliding ratios be 1.1 per section 1807.2.3 of IBC 2009 or IBC 201 Vertical component of active lateral soil pressure IS considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS considered in the calculation of Overturning Resistance. Soil Over Heel 268.7 2.33 626.8 Sloped Soil Over Heel Surcharge Over Heel Adjacent Footing Load = Axial Dead Load on Stem = Axial Live Load on Stem = Soil Over Toe 97.8 0.67 65.2 Surcharge Over Toe Stem Weight(s) 366.6 1.67 610.9 Earth @ Stem Transitions Footing Weight 333.3 1.33 444.2 Key Weight Vert. Component 2.67 Total 1,066.3 lbs R.M.= 1,747.1 Axial live load NOT included in total displayed, or used for overturning resistance, but is included for soil pressure calculation. RetainPro (c) 1987-2017, Build 11.17.07.27 License: KW-06057724 Cantilevered Retaining Wall License To: SOUND STRUCTURAL SOLUTIONS, INC Fil I -_t I Horizontal Deflection at Top of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 250.0 pci Horizontal DO @ Top of Wall (approximate only) 0.034 in The above calculation is not valid if the heel soil bearing pre -s-ure exceeds that of the LD�, because the wall would then tend to rotate into the retained soil. PR i how r 6W Ono Code: IBC 2015,ACI 318-14,ACI 530-13 RetainPro (c) 1987-2017, Build 11.17.07.27 License : KW'06057724 Cantilevered Retaining Wall Code: IBC 2015ACI 318-14,ACI 530-13 License To: SOUND STRUCTURAL SOLUTIONS, INC Criteria [-Soil Data Retained Height 3.67 ft Allow Soil Bearing mmmm"2,000.0 Psf Wall height above soil 0.00 ft Equivalent Fluid Pressure Method Active Heel Pressure 45.0 psf/ft Slope Behind Wall 0.00 Height of Soil over Toe 8.00 in Water height over heel 0.0 ft Passive Pressure 300.0 psf/ft Surcharge Loads Surcharge Over Heel 0.0 psf Used To Resist Sliding & Overturning Surcharge Over Toe 0.0 Used for Sliding & Overturning [Axial Load Applied to Ste Axial Dead Load 0.0 lbs Axial Live Load 0.0 lbs Axial Load Eccentricity 0.0 in Design Su Wall Stability Ratios Overturning 2,56 OK Sliding 1.79 OK Total Bearing Load 1,066 lbs ... resultant ecc. 4.02 in Soil Pressure @ Toe 702 psf OK Soil Pressure @ Heel 98 psf OK Allowable 2,000 psf Soil Pressure Less Than Allowable ACI Factored @ Toe 982 psf ACI Factored @ Heel 138 psf Footing Shear @ Toe 5. 1 psi OK Footing Shear @ Heel 2.7 psi OK Allowable 75.0 psi Sliding CaIcs, Lateral Sliding Force 455.5 lbs less 100% Passive Force = - 337.5 lbs less 100% Friction Force = - 479.8 lbs Added Force Req'd 0.0 lbs OK .... for 1.5 Stability 0.0 lbs OK Soil Density, Heel = 110.00 pcf Soil Density, Toe = 11 O�00 Pcf FootingIlSoii Friction 0.450 Soil height to ignore for passive pressure 0.00 in Lateral Load Applied to Stem Lateral Load 0.0 #/ft ... Height to Top 0.00 ft ... Height to Bottom 0.00 ft Load Type = Wind (W) (Service Level) Wind on Exposed Stem = 0.0 psf (Service Level) [�Stem Constr Design Height Above Ftg ft Wall Material Above "Ht" Design Method Thickness Rebar Size Rebar Spacing Rebar Placed at Design Data fb/FB + fa/Fa Total Force @ Section Service Level lbs Strength Level lbs Moment .... Actual Service Level ft-# = Strength Level ft-# = Moment ..... Allowable Shear ..... Actual Service Level psi = Strength Level psi = Shear ..... Allowable psi = Anet (Masonry) in2 = Rebar Depth 'd' in= Masonry Data fm psi = Fs psi = Solid Grouting Vertical component of active lateral soil pressure IS Modular Ratio 'n' considered in the calculation of soil bearing pressures. XA1 11 VAI ; � Load Factors Building Code IBC 2015,ACI Dead Load 1.200 Live Load 1.600 Earth, H 1.600 Wind, W 1.000 Seismic, E 1.000 a eg t ps Short Term Factor Bottom Adjacent Footing Load Adjacent Footing Load 0.0 lbs Footing Width 0.00 ft Eccentricity 0.00 in Wall to Ftg CL Dist 0.00 ft Footing Type Line Load Base Above/Below Soil at Back of Wall 0.0 ft Poisson's Ratio 0.300 Stem OK 0.00 Concrete LRFID LRFD LRFD 8.00 # 4 16.00 5.75 i 0.157 483.8 591.2 3,761.8 7.0 75.0 5.75 100.0 r-quiv. So,Iu , mcK. Masonry Block Type = Medium Weight Masonry Design Method = ASD Concrete Data fc psi = 2,500.0 Fy psi = 60,000.0 W JIM Nod W MN low am wow b� Will : 111" wo RetainPro(c)1987-2017, Build 11.17.07.27 License: KW-06057724 Cantilevered Retaining Wall Code: IBC 2015ACI 318-14,ACI 530-13 License To: SOUND STRUCTURAL SOLUTIONS, INC Concrete Stem Rebar Area Details Bottom Stem Vertical Reinforcing Horizontal Reinforcing As (based on applied moment): 0.0242 in2/ft (4/3) * As : 0.0323 in2/ft Min Stem T&S Reinf Area 0.880 in2 200bd/fy: 200(12)(5.75)/60000 0.23 in2/ft Min Stem T&S Reinf Area per ft of stem Height: 0.240 in2/ft 0.0012bh : 0.0012(12)(8): 0. 1152 in2/ft Horizontal Reinforcing Options : One layer of: Two layers of: Required Area 0. 1152 in2/ft #4@ 10.00 in #4@ 20.00 in Provided Area 0. 15 in2/ft #5@ 15.50 in #5@ 31.00 in Maximum Area: 0.7789 in2/ft #6@ 22.00 in #6@ 44.00 in Footing Dimensions & Strengths Footing Design Results Toe Width 1.33 ft Toe Heel Heel Width 1.33 Factored Pressure 982 138 psf Total Footing Width 2.67 Mu': Upward 748 46 ft-# Footing Thickness 10.00 in Mu': Downward 211 141 ft-# Mu: Design 536 95 ft-# Key Width Key Depth 0.00 in 0.00 in Actual 1 -Way Shear = 5.06 2.71 psi Key Distance from Toe 0.00 ft Allow 1-Way Shear = 40.00 40.00 psi Toe Reinforcing = None Spec'd fc 2,500 psi Fy 60,000 psi Heel Reinforcing = None Spec'd Footing Concrete Density = 150.00pcf Key Reinforcing = None Spec'd Min. As % 0.0018 Other Acceptable Sizes & Spacings Cover @ Top 2.00 @ Btm.= 3.50 in Toe: #4@ 11.11 in, #5@ 17.22 in, #6@ 24.44 in, #7@ 33.33 in, #8@ 43.89 in, #9@ 5 Heel: Not req'd: Mu < phi*5*lambda*sqrt(fc)*Sm Key: No key defined Min footing T&S reinf Area 0.64 in2 Min footing T&S reinf Area per foot 0.24 in2 A If one layer of horizontal bars: If two layers of horizontal bars: #4@ 10.00 in #4@ 20.00 in #5@ 15.50 in #5@ 31.00 in #6@ 22.00 in #6@ 44.00 in Summa of Overturning & Resisting Forces & Moments ..... OVERTURNING .... ..... RESISTING ..... Force Distance 6ment Force Distance Moment Item lbs ft ft-# lbs ft ft-# Heel Active Pressure Surcharge over Heel Surcharge Over Toe Adjacent Footing Load Added Lateral Load Load @ Stem Above Soil Total 455.5 1.50 683.1 455.5 O.T.M. 683.1 Resisting/Overturning Ratio 2.56 Vertical Loads used for Soil Pressure 1,066.3 lbs Vertical component of active lateral soil pressure IS considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS considered in the calculation of Overturning Resistance. Soil Over Heel 268.7 2.33 626.13 Sloped Soil Over Heel Surcharge Over Heel Adjacent Footing Load = Axial Dead Load on Stem = Axial Live Load on Stem = Soil Over Toe 97.8 0.67 65.' 2 Surcharge Over Toe Stem Weight(s) 366.6 1.67 610.9 Earth @ Stem Transitions Footing Weight 333.3 1.33 444.' 2 Key Weight Vert. Component 2.67 Total 1,066.3 lbs RX= 1,747.111 Axial live load NOT included in total displayed, or used for overtuming resistance, but is included for soil pressure calculation. RetainPro (c) 1987-2017, Build 11.17.07.27 Pq License: KW-06057724 Cantilevered Retaining Wall Code: IBC 2015ACI 318-14,ACI 530-13 License To: SOUND STRUCTURAL SOLUTIONS, INC Tilt Horizontal Deflection at Top of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 250.0 pci Horizontal Defi @ Top of Wall (approximate only) 0.027 in The above calculation is not valid if the heel soil bearin p�eL aw g �qrtexceeds that of the toe because the wall would then tend io rotate into the retained soil. IN am P0 bw P" Mw Pw C, DETAIL ANALYSIS 6628 212th Street SW, Suite 205 - Lynnwood, WA 98036 - Ph: 425-778-1023 - Fax: 206-260-7490 BHS - BEAM & HEADER SUPPORT 2x BM Species HF Stud Species HF Stud Height 9 Wk Braced Yes REQUIRED STUDS: BEAM 2x4 2x6 2x8 2-2x (SAWN) 4x (SAWN) 2-2x4 2-2x6 2-2x8 3-1/2 (MAN F) 3-2x (SAWN) 6x (SAWN) 3 -2x4 3-2x6 I 3-2x8 5-1/4" (MAN F) 6-3/4 (GLB) 4 - 2x4 4-2x6 I 4-2x8 7 (MANF) I G.T. 1 3 - 2x4 I 3-2x6 3 -2x8 REQUIRED TRIMMERS: HEADER 2x4 2x6 2x8 2-2x (SAWN) 4x (SAWN) 1 2x4 I - 2x6 1 - 2x8 3-1/2 (MAN F) 3-2x (SAWN) 6x (SAWN) --- 2-2x6 2-2x8 5-1/4" (MANF) 6-3/4 (GLB) 3 -2x8 7 (MANF) 7, 7. 'AMO k*Y4*VM A*'* Mtt*^Wt* 14 A W CAPACITY: H=9ft HF BEAM 2x4 2x6 2x8 2-2x (SAWN) 4x (SAWN) 3-1/2 (MAN F) 3645# 3645# 36457 3988# B 4252# PC 4252# PC 3-2x (SAWN) 6x (SAWN) 5-1/4" (MANF) 5982# 8201# 8201# 5982# B 9568# PC 9568# PC 6-3/4 (GLB) 7 (MANF) 17977# BI I 13365# PC 15035# PC G.T. 1 4252# 1 6682# 6682# CAPACITY: H=9ft HF HEADER 2x4 2x6 2x8 2-2x (SAWN) 4x (SAWN) 3-1/2 (MANF) 1822# 1822# 18227 1994# B 3281 # PC 3281# PC 3-2x (SAWN) 6x (SAWN) 5-1/4" (MANF) --- 5467# 5467# 6682# PC 8808# PC 6-3/4 (GLB) 7 (MANF) 13213# PC in ft" BHS - BEAM & HEADER SUPPORT bow 2x BM Species HF Stud Species HF Stud Height 9.5 ,Wk Braced Yes REQUIRED STUDS: BEAM 2x4 2x6 2x8 2-2x (SAWN) 4x (SAWN) 2-2x4 2-2x6 2-2x8 3-1/2 (MAN F) 3-2x (SAWN) 6x (SAWN) 3 - 2x4 1 3-2x6 3-2x8 5-1/4" (MAN F) 6-3/4 (GLB) 4 - 2x4 4-2x6 4-2x8 7 (MAN F) G.T. 3 - 2x4 x8 REQUIRED TRIMMERS: HEADER 2x4 2x6 2x8 2-2x (SAWN) 4x (SAWN) 1 - 2x4 1 - 2x6 1 - 2x8 3-1/2 (MANF) 3-2x (SAWN) 6x (SAWN) - - 2-2x6 2-2x8 5-1/4" (MANF) 6-3/4 (GLB) 3 - 2x8 7 (MANF) 1pm m.w po INN wo ".4 zx V. �,l a T--1 A410 lw jx cf� XW A MECCA L—J Ku. CAPACITY: H=9.5ft HF BEAM 2x4 2x6 2x8 2-2x (SAWN) 4x (SAWN) 3-1/2 (MANF) 3608# 3645# 3645# 3608# B 4252# PC 4252# PC 3-2x (SAWN) 6x (SAWN) 5-1/4" (MANF) 5412# 8201 # 8201# 5412# B 9568# PC 9568# PC 6-3/4 (GLB) 7 (MANF) 7216# B 13365# PC 15035# PC G.T. 4252# 6682# 6682# CAPACITY: H = 9.5 ft HF HEADER 2x4 2x6 2x8 2-2x (SAWN) 4x (SAWN) 3-1/2 (MANF) 1804# 1822# 1822# 1804# B 3281 # PC 3281# PC 3-2x (SAWN) 6x (SAWN) 5-1/4" (MANF) --- 5467# 5467# 6682# PC 8808# PC 6-3/4 (GLB) 7 (MANF) 13213# PC BHS - BEAM & HEADER SUPPORT 2x BM Species HF Stud Species HF Stud Height 10,25 Wk Braced Yes ft REQUIRED STUDS: BEAM 2x4 2x6 2x8 2-2x (SAWN) 4x (SAWN) 2-2x4 2-2x6 2-2x8 3-1/2 (MANF) 3-2x (SAWN) 6x (SAWN) 3 - 2x4 3-2x6 1 3-2x8 5-1/4" (MANF) 6-3/4 (GLB) 4 - 2x4 4-2x6 I 4-2x8 7 (MANF) G.T. 3 - 2x4 I 5-2x6 3-2x8 REQUIRED TRIMMERS: HEADER 2x4 2x6 2x8 2-2x (SAWN) 4x (SAWN) I - 2x4 1 - 2x6 1 - 2x8 3-1/2 (MANF) 3-2x (SAWN) 6x (SAWN) 2-2x6 2-2x8 5-1/4" (MANF) 6-3/4 (GLB) 3 - 2x8 7 (MAN F) 7a V, 'T CAPACITY: H = 10.25 ft HF BEAM 2x4 2x6 2x8 2-2x (SAWN) 4x (SAWN) 3-1/2 (MANF) 3128# 3645# 3645# 3128# B 4252# PC 4252# PC 3-2x (SAWN) 6x (SAWN) 5-1/4" (MANF) 4693# 8201 # 8201# 4693# B 9568# PC 9568# PC 6-3/4 (GLB) 7 (MANF) 6257# B 13365# PC 15035# PC G.T. 4252# 6682# 6682# CAPACITY: H=10.25ft HF HEADER 2x4 2x6 2x8 2-2x (SAWN) 4x (SAWN) 3-1/2 (MANF) 1564# 1822# 1822# 1564# B 3281 # PC 3281# - PC 3-2x (SAWN) 6x (SAWN) 5-1/4" (MANF) --- 5467# 5467# 6682# PC 8808# PC 6-3/4 (GLB) 7 (M NF) 13213# PC ON 6.0 BHS - BEAM & HEADER SUPPORT 2x BM Species HF Stud Species HF Stud Height 11.5 Wk Braced Yes REQUIRED STUDS: BEAM 2x4 2x6 2x8 2-2x (SAWN) 4x (SAWN) 2-2x4 2-2x6 2-2x8 3-1/2 (MAN F) 3-2x (SAWN) 6x (SAWN) 3 - 2x4 3-2x6 1 3-2x8 5-1/4" (MANF) 6-3/4 (GLB) 4 - 2x4 4-2x6 4-2x8 7 (MANF) G.T. 3 - 2x4 3 - 2x6 3 - 2x8 REQUIRED TRIMMERS: HEADER 2x4 2x6 2x8 2-2x (SAWN) 4x (SAWN) I - 2x4 1 - 2x6 1 - 2x8 3-1/2 (MANF) 3-2x (SAWN) 6x (SAWN) 2-2x6 2-2x8 5-1/4" (MANF) 6-3/4 (GLB) 3 - 2x8 7 (MANF) W-7 o.- CAPACITY: H = 11.5 ft HF BEAM 2x4 2x6 2x8 2-2x (SAWN) 4x (SAWN) 3-1/2 (MAN F) 2513# 3645# 3645# 2513# B 4252# PC 4252# PC 3-2x (SAWN) 6x (SAWN) 5-1/4" (MANF) 3770# 8201 # 8201# 3770# B 9568# PC 9568# PC 6-3/4 (GLB) 7 (MANF) 5027# B 13365# PC 15035# PC G.T. 1 3770# 6682# CAPACITY: H = 11.5 ft HF HEADER 2x4 2x6 2x8 2-2x (SAWN) 4x (SAWN) 3-1/2 (MAN F) 1256# 1822# 1822# 1256# B 3281 # PC 3281# PC 3-2x (SAWN) 6x (SAWN) 5-1/4" (MAN F) --- 5467# 5467# 6682# PC 8808# PC 6-3/4 (GLB) 7 (MANF) 13213# PC DTC - DIAPHRAGM TO COLLECTOR Location Wall Line: 3 Story: I Collector Species LVL Sheathing Thinkness 23/32, Sheathing S.G. 0.50 Nail Size 10d Nail Type Box. ex-l-TAlly NO-, k*lc — \ -!, Ltllcni O� Vjl�CTDI p. I KA �L L 7 v4 RAGY Fm- SiNzix"Al wr-$ INTERME7DIATE WvjNG A5071714G PANE� EDGES in DIAPHRAGM TO COLLECTOR DTC ,--i NTS, lLoad Duration Factor Wind/Quake 1.6 I Diaphragm Factor Yes 1.1 Collector Length 28 Collector Load (0.6W) 1900 Collector Load (0.7E) 3500 1] lbs lbs I Adjusted Bearing, Z' I 1501lbs v (plf) Design Spacing (in) 68 26.46 125 14.36 Nail Spacing 6 in Wind Seismic Connection Capacity 8378 lbs Stressed 42% OK Use 10d Box Nails @ 6 inches OC Floor Performance Geometry: Sheathing: Load: Display: Floor Depth 14 INorninal Clear Span 21.75 7ft Spacingl 16 -1 in Type I ply—] Thicknessl 23/3 in Dead Load 1 4.5 psf *floor weight neglecting joists and sheathing Live Load 1 40 1 psf Joistl All Performancel B and better (i) - Floor performance A+ - D- are passing grades (ii) - Limiting unity of strength and joist delfection (L/480) (iii) - Economic efficiency based on the cheapest option (iv) - Price per square foot or joists and plywood (v) - Precise weight of floor (i) (H) (M fx/) Date: Job # Joist Performance Unity % Economy sqft Floor Weight 14 PWI-90 @ 16 B+ 80% 1.00 4.30 10.6 (2) 14 TJ 12 10 @ 16 B+ 0% 1.05 4.50 11.7 14 TJ 1560 @ 16 B+ 81% 1.15 4.93 10.2 (2) 14 TJ 1230 @ 16 !B+ 0% 1.24 5.34 12.0 (2) 14 TJ 1360 @ 16 A+ 0% 1.58 6.81 12.0 (2) 14 TJ 1560 @ 16 A+ 0% 2.29 9.86 13.4 1/11/2019 s1811020 *add 2 psf for design purposes IBW - INTERIOR BEARING WALL INTERIOR BEARING WALL Indicates interior walls which support repetitive members, Construct per WALL FRAMING & BEARING In the GENERAL STRUCTURAL NOTES, U.N.O. on the plan. Dead Live Snow Deck 20 60 25 Floor 20 40 Roof 20 25 Wall 10 Bearing Capacity 2000 0-2 Tributary Dimension Type of Load Dead Load Live Load Snow Load Total Load 0 Deck 0 0 0 0 11 Floor 220 440 0 660 0 Roof 0 0 0 0 9 Wall 90 0 0 90 Total 310 440 0 750 STUD SPACING in Dead Load, lb Live Load, lb Snow Load, lb Total Load, lb 16 413 587 0 1000 ON PW wo P" emw P" PM IHC - INVERTED HANGER AT CANTILEVER Beam Reaction Dead, D 310 Live, L 435 Snow, S 517 Wind, W 0 ,Seismic, E 0, lb Location I lb BEAM #: 1-6 j lb lb SDS 1.0 lb Controling Combo: D + 0.75L + 0.75S Support-ed Member Size 1width I 1.75jin Idepth 1 11.8751 in Support-! g Member Size 1width 1 5.25 in Idepth 1 11.82� in Connection Geome �� 0.875 in jarm 1 11.825 in Required Resistance to Rotation TOP T = lbs BTM T = lbs Torsional Resistance from Shpathina Sheathing Thinkness 23/32 Sheathing S.G. 0.50 Nail Type Box Nail Size 10d Nail Spacing 6 Sheathing Condition Center Theoretical # of Nails 8 Connection Capacity 521 Stressed 15% Load 1024 lb Species LSL Species PSL Duration Factor r, I ��ELILI FLOOOR 01APHRAC-M PER STU nluk 'cd @ 4"OC NOTES HkM OR 3-05PT PER fUN flAr , GER PER PLM' BEAM OR)OIST INSTALLED WSIDE-COWIN, PER PA FIHC� INVERTED HANGER AT CANTILEVER Lj N.T.S' FLOOR OTAWRI01 a STRUCTRUAL NOGTES FAM PER PJ'A t 1,115TC4853 KWA PER PJAN SEA". PER IN57ALLED UPSIDE-001WN PLAN in PK INVERTED [ANGER AT CANTILEVER L—i R.T.S. fbs OK Resistance from Tension St aps Top Strap NOT REQUIRED Width in Zonnection Capacity --- lbs Lengthl --- in Stress --- --- Bottom Strap NOT REQUIRED WidthF— 7-7-1 in Zonnection Capacity lbs Length in Stress Inverted Hanger Duration Factor OK OK HU Capacity Stress .Down (Ibs) 2685 38% , .Uplift (Ibs) 1345 76% IHC - INVERTED HANGER AT CANTILEVER Beam Reaction Dead, D 382 lb Live, L 0 lb Snow, S 477 lb Wind, W 0 lb Fs—eismic, E 0 lb Controling Combo: D + S Support-e Member Size 1width I ' ' in Idepth 1 ::1:1:j.51 in Support-i g Member Size 1width 1 5.25 in Idepth 1 181 in Connection Geometry le 1 0.75 1 in jarm 1 18 in Required Resistance to Rotation TOP T = lbs BTM T = lbs Torsional Resistance from Sheathino Location �—BEAM 4t: 2-5 1 SDS 1.0 Sheathing Thinkness 23/32 Sheathing S.G. 0.50 Nail Type Box Nail Size 10d Nail Spacing 6 Sheathing Condition Center Theoretical # of Nails 8 Connection Capacity 521 Stressed 7% Load 859 lb Species DF #2 Species DF #2 j Duration Factor in �i FLOOR OWHRAGM P FR 57KX�, RJAL r— 10d @� 4oc AOTI ES : ' BEAM ORMIST PER PLAN ,4ANGER PER pLg� BEAM OR JOIST INSTALLED IJPSID�OOWN J PER PL44 F1HCj INVERTED HANGER AT CANTILEVER LiK.T.S' F OOR DIAPHRAGM PEER STRIJ0 RUAL NOTES FAN PER PIA * MSTC4BB3 KkNG.3t F; OW BW, PER IPSTALLED UPSVF�DOWN PIAN in a) INVERTED HANGER AT CANTILEVER L—i V.S. lbs OK Resistance from Tension Straps Top Strap --- NOT REQUIRED W'idth in Connection Capacity --- lbs Length in Stress Bottom Strap --- NOT REQUIRED WidthF— in lConnection Capacity I --- --]Ibs Lengthl --- in Stress Inverted Hanger Duration Factor OK OK P--E] HU Capacity Stress Down (Ibs) 2685 329/6 Uplift (Ibs) 1345 64% P" Ww i OR I F0 i FM "M 00 Omni Pw IHC - INVERTED HANGER AT CANTILEVER Beam Reaction Dead, D 285 Live, L 0 Snow, S 356 Wind, W 0 [Seismic, E O� lb lb lb lb lb Controling Combo: D + S Suppoirtt-e Member Size 1width 1 1. 5 in Idepth I 11.251in Support-ing Member Size 1width 1 5.251 in Idepth - 1 7 112 51 in Connection Geometry Location BEAM #: 2-11 SDS 1.0 Species DF #2 j Species PSL le 1 0.75 lin jarm 1 11.25 lin Duration Required Resistance to Rotation Factor TOP T = lbs BTM T = lbs Torsional Resistance from Sheathina Sheathing Thinkness 23/32 Sheathing S.G. 0.50 Nail Type Box Nail Size 10d Nail Spacing -�heathing 6 Condition Center Theoretical # of Nails 8 Connection Capacity 521 Stressed 8% Load 641 lb FLOOR D'"PAGM PER 5`RJC TRU -'L 10TES 10 @ 4'oc KAM ORMIST PER PLAN NZER PER FILM HAm ORJOISI INSTALLED UDSMOGATi PER RM F1HCj INVERTED KANGER AT CANTILEVER Li N.T.S. FLOOR DIAWRAGM PER SRUCrRJAL IVES WWI PER PIAN t PSM403 KNUR PDk DIAN aWk, PER W-1ALLED U;]DW" V'N RAN in (:�fl INVERTED HANGER AT CANTILEVER LiN.T.S. fbs OK Resistance from Tension Straps Top Strap NOT REQUIRED W'idth Connection Capacity lbs Length in Stress Bottom Strap —]NOT REQUIRED Width in Zonnection Capacity --- Ilbs Length I in Stress --- I Inverted Han er Duration Factor OK OK HU Capacity Stress (Ibs) 2685 24% .Down .Uplift (Ibs) 1345 48% NSB - NAILER TO STEEL BEAM Location Wall Line: 2 Story- 1 lWind Shear (0.6W) 650, lbs ISeismic Shear (0.7E) 23001lbs Nailer Nailer Species HF Nailer Thickness 1.5 in Nailer Width 5.5 in Bolts or Threaded Studs iameter 0. 5 in pacing 24 in otal # Fast. 10 # D S T Countersunk? No ITotal Cap. I i 8 kip Max = 2300 lbs Wood Bearin Z 520 lb Cd 1.60 Cg 1.00 CA 1.00 Z' 832 lb Stress 27.6% OK Bearn LengthF— 2-2-6 71 ft Less in Net Length L:Aft PROJFCT NOTES: TINE PROJFC,T: R25T=HV4ff_�_ ONNEF: FAI"IN05 DEVELOPMENT 15110 NE PITH PL, SUITE 114 1100DINVILLE, KA q8012 42534155151 - OFFICE 425.452.2136 - FAX FROJECT ADDRESS: �1'1 PINE STREET LOT 3 PARCEL NO. 27032500105500 JURISDICTION: CITY OF EDMONDS PROJECT NOTES: ZONIN6: R5 b LOT AREA: SHORT PLAT &,602 5F HOLGIN6, TYPE DETACHE12 RESIDENT IAL EGO 16.20. LIEVES 5IN(5LE FAMILY DYIIELLINIS UNITS EX 16.20.010 A. PERMITTED PRIMARY USES- 1. SIN&LE FAMILY OVELLIN6 UNITS 506 16.20.050 51TE DEVELOPMENT STANDARDS U DENSITY: 55 UNIT PER Ar, PROPOSED: I UNITS MAX COVERA6E: &AO2 5F X 55% 5010.1 SF PROPOSED LOT COVERACSE: N EX15TINCS: o 5F (DEMO ExIsTINS) PROPOSED NEM 2,104.0 5F TOTAL 2,7104.0 5F SETBACKS: STREET 25'MIN. 51DE 15MIN. > LLJ REAR 15'MIN. (No REAR FOR 0�*LOI*5) HEI6HT: 25MAXIMUM 5' ADDITIONAL Poor (4/ itS�m 0 FARK[Nrv: 0 LLJ ECC 1150.00 OFF5TREET PARKING REGUIRED 0 Q0 < ECC 11,50.020 PARKIN67 SPACE REMIREMENT 5INSLE FAMILY DMI-LING: 2 PER UNIT 0 PROPOSED: 3 STALI-5 00 LEVEL (9ARA(r7E LIVIN(5 DECK IR5T 160.0 1653.0 SECOND 2,153.0 360.0 ROOF --- --- 460.0 TOTAL 160.0 5'DOC'.0 e1:20.0 A residential fire sprinkler system is required. A recommended flow -through design will meet specifications and reduce equipment and continuing maintenance requirements. ECDC19.05.020132. Provide a minimum combination water service of one (1") meter and one and one half (11/2") service line, or show that domestic and fire protection need can be rTlqt with a smaller service. 640:�� 4 0 11— �R 014GINEERM DIVI61ON 8 NOTED % T*S S-M '00jst_olpmr�� —.b c4vtwe� folL LO 30' Im AVERA6E ORIC71NAL CALCULATION: PI: 0625 P2 P5 5. P4: 106.15 AVC7 65R: 4-45.75/4 IIOA4 N 88'52'2-/7" W 218. PI: 106.25 99.09, 14 -12' '17- 25' -PROZECI _W rE5 E I `14MAX 77,% HT425)— 35.114 6ARAbE SLAB: 1105 OF --- — 2.0/135 BE'-, FLOOR- 2.0 iiQFL�01 - 11.0/112.0 (9AM6EI51-1 - 10.5 P4 106.15 ?7" 77/1( 1p?'1QFwA'j. D 3 7, "9 88'52'27" 1 3 Ell id A AVL�?RA 0 F F FL 1- '001 11, _( 1 10 �7" 1%1 3 7, 88-5227 Iddif 3A FH 0 25' A L OR� S 45 EA5EM5 T TO FllELD IN PECTION FOR E CO�PLIANCE C, C . — I C co (b 0 �D 0 99. 21 d' U 5' CONC. WALK CONCRETE VURB Q0 to 00 lf'o I C\� ON Zone 2 Corner� Flag_ / Setback BUC 12"Cr C C� Actual ILITY DAPF EDMONDS 12' CONIC Front L �13 WORK G DEPARTMENT Sides ADDR"_____z_�4 Rear Ofti�� Other 07' APPROViD ATE 'A PLMMNG-- BLDG. OFFICI L­.' 'I N 8 8 5 2'2n' 00 1 PER IT NUMBER 0 6 Cl WAT 7 )0' f POINT: I BA51N TOP ITION 100.10 R--ED ,MCHn'ECT 9. NOVION L!"l? GROUP INC. 8634B 3RD W SEkTWTRL�E H 98117 PH(206 .6133FAX361.6345 4 �NER/CIJEW 3:z LU '5- 41C ts- E X LL 'OVIFF I Ld ty I M td Eu 5a wn W gi Lri 13 N N 4- 5 /8 PT _VE �IR. .1 ,FEB Z 1 2011% §91 1 \ E E I/W=I' 0.1 D­ Rn Kn J� SECURITY DETACHF-12 ONE -FAMILY VNELLIN65 AND DUPLEX.- 1. BUILDING ENTRANCE LOOKS. Building entrance doors, including garage doors, shall be capable of looking. They shall be equipped vilth a clead-locking latch bolt v4ith at least a 1/2 - inch throyq Yqhlch penetrates the striker not less than 1/4 - inch. Building entrance doors sholl be operable from the Inside Yi1thout use of a key or special knoy4ledge or effort PER IRC 521.1. EXCEPTION: Saroge - to - exterior cloors may be equipped Yilth an electronically - operated remote control device for opening and closing in lieu of a deadlocking latch bolt . ften garage - to - exterior doors are equipped vilth remote control devices, garage - to - building cloors need not be, capable of looking. 2. OBSERVATION FORTS. Every building entrance door, other than garage doors, shall hove a visitor observation port or gloss side light. Observation ports sholl be installed at a height of not less than 54 inches and not more than 66 inches from the floor PER IRr_ P,52CI.2. 5. AINDOIA15 AND SLIDING DOORS. Dead bolts or other approved larking devices shall be provided on all sliding doors and openoble viinclovis. The lack sholl be installed so that the mounting screp4s for the look case ore Inaccessible from the outside PER IRC R52CI.5. EXCEPTION: 1/41ndov4r. vilth sills located 10 feet or more above grade, or 10 feet or more above a dock, balcony or porch that is not readily accessible from gracle except through a housing unit need not have, operable Inside latching devices. oyqNER / CONTRACTOR NOTES 1. CONTRACTOR TO PHYSICALLY INSPECT SITE PRIOR TO COMMENCING ANY VqORK. REPORT ANY r,>l5rREFANOY To ARCHITECT. CONTRACTOR TO REVIEyq CONSTRUCTION DOCUMENTS PRIOR To COMMENCING CONSTRUCTION. ANY QUESTIONS SHOULD BE DIRECTED To OANER AND/OR ARCHITECT CONTRACTOR TO C.RO55-REFERENOE V41TH CITY APPROVED PLANS FOP, ANY CHANGES ANP/OR ADDITIONAL REQUIREMENTS By CITY. 2. ALL INFORMATION CONTAINED IN THESE DOCUMENTS REPRESENTS A "BASIC LIMITED ARCHITECTURAL SERVICE" THAT REQUIRES THE CONTRACTOR TO BE KNONLFD&EA5LE AND EXPERIENCED VqITH ALL ASPECTS OF CONSTRUCTION INCLUDING ALL BUILDING CODES AND REGULATIONS IMPOSED BY THE CITY OR COUNTY AND ANY OTHER AGENCY HAVING JURISDICTION OVER THE PROJECT. 3. ALL VqORK SHALL COMPLY Y41TH THE STATE AND LOCAL ORDINANCES, AND SHALL BE DONE To THE H16HEST STANDARDS OF CRAFTSMANSHIP By JOURNEYMEN OF THE RESPECTIVE TRADES. 4. THE r-ONTRAcTOR SHALL CARRY ALL INSURANCE REQUIRED BY LAYq. 5. SAFETY, CARE OF. ADJACENT PROPERTIES DURING CONSTRUCTION, COMPLIANCE Y41TH LOCAL, STATE, FEDERAL REGULATIONS RE&ARDIN& SAFETY ON SITE SHALL BE THE CONTRACTORS RESPONSIBILITY. 6. No DEVIATIONS FROM THESE DOCUMENTS SHALL BE MADE P41THOUT INRITTEN APPROVAL FROM ARCHITECT. ANY CHANGES (:,AN AFFECT THE STRUCTURAL INTEGRITY AND CODE RELATED 155UES OF THE STRUCTURE. -1. ALL INFORMATION CONTAINED IN THESE DOCUMENTS 15 FOR THE PURPOSE OF CONSTRUCTION PERMIT ACQUISITION AND CONSTRUCTION ONLY. THE INFORMATION PROVIDED 15 NOT INTENDED FOR ANY OTHER PURP05E AND No OTHER USE 15 INTENDED OR IMPLIED.e.q. PLAN INFORMATION IS NOT INTENDED To BE USED AS A EASE FOR SALE OR TRANSFER OF REAL ESTATE - 5. "BASIC LIMITED 5ERvicv FiRovices THE LOYIE5T LEVEL OF ARCHITECTURAL SERVICE VqITH NO DRANIN65 AND SPECIFICATIONS PROVIDED OTHER THAN REQUIRED FOR PERMITS q. UNLESS OTHERY,115F SPECIFIED, ELECTRICAL, MECHANICAL,-ETO. 15 BIDDER DESIGNED, OINNER ANP/OR AGENT (CONTRACTOR) 15 RESPONSIBLE FOR ALL YqORK DONE ON 51TE (FIELD) AS To PROPER INSTALLATION, ETC,. 10. THE ARCHITECT MAY A5515T IN COORDINATION V41TH CONSULTANTS (SUCH AS SOILS, STRUCTURAL, CIVIL ENGINEERS, ETC), BUT UNDER , THE TERMS OF 5A51c LIMITED SERVICE, RECEIVES NO COMPENSATION FOR AND A55UMES NO RE5FONS15ILITY OR LIA131LITY FOR, THE AREA OF THEiR'(CONWILTANTS) ViORK AND EXPERTISE. ACCEPTANCE OF THESE PLANS FOR CONSTRUCTION CONSTITUTES AN UNDERSTANDING OF ABOVE MENTIONED ITEMS AND BASIC LIMITED ARCHITECTURAL 5ERVIGE AS DESCRIBED IN AGREEMENT BETYiEEN OY4NFR/AROHITECT GENERAL NOTES 1. ALL CONSTRUCTION TO COMPLY V41TH THE 2015 INTERNATIONAL RESIDENTIAL CODE, STATE ENER.6Y CODE, AND ALL OTHER APPLICABLE RE&UILATIQN5 AND AMENDMENTS. 2015 IRC, VqITH CITY OF EDMONDS AMENDMENTS. 2. SECURE ALL REQUIRED PERMITS. CALL FOP, ALL REQUIRED INSPECTIONS. S. ALL FOOTINGS TO BEAR ON FIRM UND15TURBED GROUND, MIN. 15 INCHES BELON FIN15HEP &RAVE. REFER TO SOILS REPORT IF ONE 15 AVAILABLE. 4. CONTRACTOR TO VERIFY EXISTING CONDITIONS, VERIFY DIMENSIONS, REPORT ANY P15CREPANCIE5 TO ARCHITECT. NO DEVIATIONS FROM PLANS SHOULD BE MADE Y41THOUT ARCHITECTS YqRITTFN APPROVAL. 5. PROVIDE SMOKE DETECTORS PER IRO R514 110 VOLTS, INTERCONNECT. 5.1 PROVIDE CARBON MONOXIDE ALARM PER IRC, R515. AN APPROVED CARE30N MONOXIDE ALARM SHALL BE INSTALLED OUT51PE OF EACH SEPARATE 5LEEFIN6 AREA AND IN THE IMFDIATE VICINITY OF THE BEDROOMS IN DYSIELLINC, UNITS AND IN EACH LEVEL OF THE DY4ELLIN& IN ACCORDANCE INITH THE MANUFACTURER'S RECOMMENDATION. INTERCONNECTED. 6. ALL EXTERIOR DOORS TO COMPLY I`qITH IRC R52q MIN 1/2 INCH THROY4 ON DEAD BOLT OR DEAD LATCH FOR DOORS. V151TOR OBSERVATION PORT FOR EXTERIOR DOORS. YqINDOINS INITHIN 10 FT. OF &RADE CAPABLE OF BEING LOOKED. ALL LOOKS MUST BE A13LE TO BE OPENED Y41THOUT THE USE OF A KEY OR ANY SPECIAL KNOYiLED(SE OR EFFORT FROM INSIDE. "I. SKYLIGHTS PER IRC, R505.6 a. SAFETY GLAZING: PER IRC R50a GLAZING IN OR V41THIN 24 IN. FROM DOORS AND GLAZING YqITHIN 15 IN. OF FLOOR OR NALKIN6 SURFACE. ADDITIONAL HAZARDOUS LOCATIONS PER IRC R305.4 -1. ALL YNOOP IN CONTACT P41TH CONORT. TIO Off FRE55URE TREATEV PER SRO R317 10 . ALL NAILING PER IRO TABLE R602.3, UNLESS OTHERV41SE CALLED IN PLANS. 11. FIREBLOOKIN6, DRAFTSTOF5, AND FIRE5TOF5 PER IRC R502.11 4 R502.12 12. LEDGER CONNECTIONS PER IRC, R50:2.6.2 15. DOUBLE J015T/BLOOK UNDER ALL BEARING PARTITIONS. IRO R502.4 14. INSTALL GROSS BRID6INry AT ALL J015T SPANS EXCEEDING EIGHT FEET. R 502.7.1 PLAN NOTES: 2015 INTERNATIONAL RESIDENTIAL CODE 1) STAIRS: COMPLY YqITH SEC. R511.1 RISE AND RUN PER R311.15.1$2 MAX RISE -7j"-R15ER HEIGHT DIFFERENCE YiITHIN FLIGHT OF 5TAR5 SHALL NOT EXCEED MIN RUN (TREAD DEPTH) SHALL BE 10". HANDRAILS FER R311.1.5, NOT LE55 THAN 541, OR MORE THAN 5e5" ABOVE STAIR NOSING, ENDS SHALL BE RETURNED OR SHALL TERMINATE IN NEY4FL F05T5 OR SAFETY TERMINALS. HAND6RIF PER RBIL-1.13: NOT LE55 THAN 1 1/4" OR MORE THAN 2" DIA., PROJECT MIN. 1 1/2" FROM ViALL. HEADROOM PER R511.8.2 6-95" MIN., ENCLOSED USABLE SPACE UNDER STAIRS SHALL HAVE INALL5 AND SOFFITS PROTECTED ON ENCLOSED 51DE PER I - HR. FIRE RESISTIVE CONSTRUCTION PER 502.1 - FIRE BLOCK PER R302.11, CONGEALED SPACES 5ETY4EEN STAIR STRINGERS AT TOP AND BOTTOM OF RUN, Br=TYqr=r=N STUDS AND ALONG LINE OF STAIRS AND R502.11 FIRE BLOCK CONSTRUCTION. 2) R502.5.1 GARAGE OPENING PROTECTION: OPENINGS BETINEEN THE GARAGE AND RESIDENCE SHALL BE EQUIPPED NITH 50LID P400D DOORS NOT LE55 THAN I 5/a INCHES IN THICKNESS, 50LID OR HONEYCOMB GORE STEEL DOORS NOT LESS THAN I 5/e, INCHES THICK, OR 20-MINUTE FIRE -RATED DOORS, EQUIPPED NITH A SELF CLOSING DEVICE. 3) TUB / 5HOINER NOTES: COMPLY NITH R50-T NON ABSORBENT SURFACE. NO VAPOR BARRIER BEHIND INATER RE51STANT &YSI.B. SPECIFIED AS BASE FOR TILE ON 5HONER ENCLOSURES, YiATER RE515TANT NOT INSTALLED ON OFILIN& IF FRAMING EXCEEDS 12" 06. ViALL5 AND SHONERS: VqATERPROOF TO -72" ABOVE DRAIN INLET. 5HOINER DOORS PER R50t3 COMPLY INITH SAFETY GLAZING REQUIREMENTS. FIREBLOOK BETNEEN STUDS. 5HOY4ER FLOIN TO 2.5 &.F.M. MAX. 4) ORANL SPACE ACCESS PER R405.4, MIN. la" X 24" UNOBSTRUCTED OPENING 5) ATTIC ACCESS PER SRO R501, 22" X 50" MIN. OPENING, 50" MIN. CLEAR HEADROOM. ROOF VENTILATION PER P506 ro) FACTORY -BUILT CHIMNEYS PER R1005 AND FIREPLACES PER R1004, To BE U-L APPROVED, LABELED AND INSTALLED PER MANUFACTURER 5PECIFICATION5 AND U.M.O. 505, ANCHORED AT EACH FLOOR AND ROOF YSJTH 2 - 1 1/2" X I/e," METAL STRAPS LOOPED AROUND OUT51DE OF CHIMNEY INSTALLATION AND NAILED YqITH NOT LESS THAN SIX(C,) 8d NAILS PER STRAP EACH JOIST. FIRE BLOCK PER R602.5, OPENING AT CHIMNEY, FIREPLACE5 AT CEILINC7 AND FLOOR LEVELS, ATTIC SPACES AND CHIMNEY CHASES. '7) GUARD RAIL5 PER R512, MIN 56" HEIGHT PEP, RSM.I, 4" MAX.SPAOE BETINEEN RAIL5- R512.5 TRIANGULAR OPENINGS AT RISER, TREAD, 50TTOM ELEMENT OF RAIL, C'" MAXIMUM. PEP, EXCEPTION I 5) HOT V4ATER HEATER SHALL MEET NAEGA 2015 REGUIREMENT5 AND BE 50 LABELED, ELECTRIC HOT Y4ATFR HEATER IN UNHEATED SPACES SHALL BE PLACED ON INCOMPRESSIBLE R-10 SURFACE. PROVIDE SEISMIC STRAPS TO STUDS. q) EMERGENCY E&RE55 PER R510, MIN. NET CLEAR OPENABLE AREA OF 5.1 50. FT., NET CLEAR HEIGHT 24" MIN., MIN. NET CLEAR OFENABLE YiIDTH 20", SILL HEIGHT NOT MORE THAN 44" ABOVE FLOOR. 10) SMOKE DETECTORS PER R314, PROVIDE PERMANENT PONER SOURCE Y41THOUT DISCONNECTINC7 eY4ITrH INITH BATTERY BACKUP PER R514.4, LOCATION PER R314.5, EACH SLEEPING ROOM AND POINT CENTRALLY LOCATED IN CORRIDOR AND IN ACCORDANCE k4ITH APPROVED MANUF'R INSTRUCTIONS. ALARM DEVICES 5HALL BE INTERCONNECTED. 11) PROVIDE CARE30N MONOXIDE ALARM PER IRC R515. AN APPROVED CARE30N MONOXIDE ALARM SHALL BE INSTALLED OUTSIDE OF EACH SEPARATE SLEEPING AREA AND IN THE IMEDIATE VICINITYOF THE BEDROOMS IN DAELLIN& UNITS AND IN EACH LEVEL OF THE DNELLIN& IN ACCORDANCE)NITH THE MANUFACTURER'S RECOMMENDATION. ALARM DEVICES SHALL BE INTERCONNECTED. 12) INDIVIDUAL ROOM OUTSIDE AIR INLETS PER M150a.4.5 - SHALL HAVE CONTROLLABLE AND SECURE OPENING NOT LESS THAN 4 50. INCHES. TESTED BY NAT. RECOGNIZED STANDARD OR APPROVED AC7ENOY LOCATED So AS NOT 70 TAKE AIR FROM FOLLOY41N&: CLOSER THAN 101 FROM APPLIANCE VENT OUTLET (UNLESS VENT 15 V-0" A50VE INLET) NHERE IT P40ULP PICK UP OBJECTIONABLE ODORS, FUMES, OR FLAMMABLE VAPORS, HAZARDOUS OR UNSANITARY LOCATIONS. ViASHIN&TON STATE ENERGY CODE NOTES: R401.2 COMPLIANCE. PROJECTS SHALL COMPLY INITH SECTIONS IDENTIFIED As "MANDATORY" AND INITH EITHER SECTIONS IDENTIFIED AS "PRESCRIPTIVE" OR THE PERFORMANCE APPROACH IN SECTION R405. IN ADDITION, ONE- AND TP40-FAMILY DViELLIN65 AND TOINNHOU5E5, AS DEFINED IN SECTION 101.2 OF THE INTERNATIONAL RESIDENTIAL CODE, SHALL COMPLY Y41TH SECTION R406. R4013 CERTIFICATE (MANr,>AToRY). A PERMANENT CERTIFICATE SHALL BE COMPLETED AND POSTED ON OR V41THIN THREE FEET OF THE ELECTRICAL D15TRIBUTION PANEL BY THE BUILDER OR RE615TERED DE516N PROFESSIONAL. THE CERTIFICATE SHALL BE COMPLETED BY THE BUILDER OR REGISTERED DE516N PROFE55IONAL AND SHALL NOT COVER OR OBSTRUCT THE V151BILITY OF THE CIRCUIT DIRECTORY LABEL, SERVICE DISCONNECT LABEL OR OTHER REQUIRED LABELS. THE CERTIFICATE SHALL LIST THE PREDOMINANT R­VALUES OF INSULATION INSTALLED IN OR ON OFILIN(9/ROOF, YiALLB, FOUNDATION (SLAB, BELOIN-61RADE INALL, AND/OR FLOOR) AND DUCTS OUTSIDE CONDITIONED SPACES; U-FACTORS FOR FENESTRATION AND THE 50LAR HEAT GAIN COEFFICIENT OF FENESTRATION, AND THE RESULTS FROM ANY REQUIRED DUCT SYSTEM AND BUILDING ENVELOPE AIR LEAKAGE TE5TINC7 DONE ON THE BUILDING. VqHERE THERE 15 MORE THAN ONE VALUE FOP, EACH COMPONENT, THE CERTIFICATE SHALL LIST THE VALUE COVERING THE LAR6E5T AREA. THE CERTIFICATE SHALL L15T THE TYPES AND EFFICIENCIES OF HEATING, COOLING AND SERVICE ViATER HEATING EQUIPMENT. NHERF A &AS -FIRED UNVENTFD ROOM HEATER, ELECTRIC FURNACE, OR BASEBOARD ELECTRIC HEATER 15 INSTALLED IN THE RESIDENCE, THE CERTIFICATE SHALL L15T "6A5-FIRED UNVENTED ROOM HEATER," "ELECTRIC, FURNACE" OR "BASEBOARD ELECTRIC 15Tr HEATER," AS APPROPRIATE. AN EFFICIENCY SHALL NOT BE L =0 FOR 6A5-FIRED UNVENTFD ROOM HEATERS, ELECTRIC FURNACES OR ELECTRIC BASEBOARD HEATERS. R403.1 CONTROLS (MANDATORY). AT LEAST ONE 7HERM057AT SHALL BE PROVIDED FOR EACH SEPARATE HEATING AND COOLING SYSTEM. R405.1.1 PROGRAMMABLE THERMOSTAT. ViHERE THE PRIMARY HEATING SYSTEM 15 A FOROED-AIR FURNACE, AT LEAST ONE THERMOSTAT PER DIAELLIN& UNIT SHALL BE CAPABLE OF CONTROLLING THE HEATING AND COOLING SYSTEM ON A DAILY SCHEDULE TO MAINTAIN DIFFERENT TEMPERATURE SET POINTS AT DIFFERENT TIMES OF THE DAY. THE THERMOSTAT SHALL ALLOV,1 FOR, AT A MINIMUM, A 5-2 PROGRAMMABLE 50HEDULE (YiEEKDA'r'S/NEEKENr,>5) AND BE CAPABLE OF PROVIDING AT LEAST TNO PROGRAMMABLE SETBACK PERIODS PER DAY.,TH15 THERM05TAT SHALL INCLUDE THE CAPABILITr'TO SET BACK OF, TEMPORARILY OPERATE THE SYSTEM TO MAINTAIN ZONE TEMPERATURES DOV4N TO 55F (15*0) OR UP TO 557- THE THERMOSTAT SHALL INITIALLY BE PROGRAMMED V41TH A HEATING TEMPERATURE SET POINT No HIGHER THAN '70'F (21 *C) AND A COOLING TEMPERATURE SET POINT NO L0104ER THAN -7e,.F (2(200). THE THERMOSTAT ANV/OR CONTROL SYSTEM SHALL HAVE AN ADJUSTABLE DEADBAND OF NOT LESS THAN I0*F. EXCEPTIONS: 1. SYSTEMS CONTROLLED BY AN OCCUPANT SENSOR THAT 15 CAPABLE OF SHUTTING THE SYSTEM OFF ViHEN NO OCCUPANT 15 SENSED FOR A PERIOD OF UP TO 50 MINUTES. 2. SYSTEMS CONTROLLED 50LELY BY A MANUALLY OPERATED TIMER CAPABLE OF OPERATINC, THE SYSTEM FOR NO MORE THAN ThO HOURS. R405.2.2 SEALING (MANDATORY�. DUCTS, AIR HANDLERS, AND FILTER BOXES SHALL BE- SEALED. JOINTS AND 5EAM5 SHALL COMPLY kNITH EITHER THE INTERNATIONAL MECHANICAL CODE OR INTERNATIONAL RESIDENTIAL CODE, AS APPLICABLE. EXCEPTIONS: 1. AIR-IMFERMEA5LE SPRAY FOAM PRODUCTS SHALL I BE PERMITTED TO BE APPLIED YqITHOLIT ADDITIONAL JOINT SEALS. 2. 1/qHERE A DUCT CONNECTION 15 MADE THAT 15 PARTIALLY INACOESSIBLE, THREE SOREIA15 OR RIVETS SHALL BE EQUALLY 5FACEr> ON THE EXPOSED PORTION OF THE JOINT 50 AS TO PREVENT A HINGE EFFECT. 5. CONTINUOUSLY VqELDED AND LOOKIN&-TYFt LONGITUDINAL JOINTS AND SEAMS IN DUCT5 OPERATINC, AT STATIC PRESSURES LESS THAN 2 INCHES OF AATER COLUMN (500 PA) PRESSURE CLASSIFICATION SHALL NOT REQUIRE ADDITIONAL OL05URE SYSTEMS. DUCTS SHALL BE LEAK TESTED IN ACCORDANCE INITH Vq5U R5-55, USING THE MAXIMUM DUCT LEAKAGE RATES SPECIFIED. DUCT TIGHTNESS SHALL BE VERIFIED BY EITHER OF THE FOLLOYqlNrv: 1. P05TOON5TRUCTION TEST: TOTAL LEAKAGE SHALL BE LE55 THAN OR EQUAL TO 4 OFM (115.3 L/MIN) PER ioo SQUARE FEET (q.2q M2) OF CONDITIONED FLOOR AREA V4HEN TESTED AT A PRESSURE DIFFERENTIAL OF 0.1 INCHES Y4.6.(25 PA) ACROSS THE ENTIRE SYSTEM, INCLUDING THE MANUFACTURER5 AIR HANDLER ENCLOSURE. ALL RESISTER BOOTS SHALL BE TAPED OR OTHERhI5F_ SEALED DURING THE TEST. LEAKAGE TO OUTDOORS SHALL BE LESS THAN OR EQUAL TO 4 OFM (155.5L/MIN) PER 100 SQUARE FEET OF CONDITIONED FLOOR AREA. 2. ROU(SH-IN TEST: TOTAL LEAKAGE SHALL -BE LESS THAN OR EQUAL TO 4 OFM (113.5 L/MIN) PER 100 SQUARE FEET (q.2q M2) OF CONDITIONED FLOORAREA 114HEN TESTED AT A PRESSURE DIFFERENTIAL OF 0.1 INCHES 1,4.6. (25 PA) ACROSS THE SYSTEM, INOLUDIN6 THE MANUFACTURER-5 AIR HANDLER ENCLOSURE. ALL REGISTERS SHALL BE TAFED OR OTHERV,115E�SEALED DURING THE TEST. IF THE AIR HANDLER 15 NOT INSTALLED AT THE TIME OF THE TEST, TOTAL LEAKAGE SHALL BE LESS THAN OR EQUAL TO 5 CFM (5r, L/MIN) PER 100 SQUARE FEET (q.2q M2) OF CONDITIONED FLOOR AREA. EXCEPTION: THE TOTAL LEAKAGE TEST 15 NOT REQUIRED FOR DUCTS AND AIR HANDLERS LOCATED ENTIRELY Y41THIN THE BUILDING THERMAL ENVELOPE. DUCTS LOCATED IN ORAJAIL SPACES DO NOT QUALIFY FOR TH15 EXCEPTION. R405.2.5 BUILDING CAVITIES (MANDAToRr). BUILDING FRAMING CAVITIES SHALL NOT BE USED AS DUCTS OR\FLENUMS. INSTALLATION OF DUCTS IN EXTERIOR KALLS, FLOORS OR CEILINGS SHALL NOT DISPLACE REQUIRED ENVELOPE INSULATION. R405.3 MECHANICAL SYSTEM PIPING INSULATION (MANDATORY). MECHANICAL SYSTEM PIPING CAPABLE OF CARRYING FLUIDS ABOVE 105-F (41-0) OR BELON 55-F (15'r,) SHALL BE INSULATED To A MINIMUM OF P,-(,. R405.5.1 PROTECTION OF PIPING INSULATION. PIPING INSULATION EXPOSED TO YeATHER SHALL BE PROTECTED FROM DAMAGE, INCLUDING THAT CAUSED BY 5UNLI&HT, MOISTURE, EOUIFMENT MAINTENANCE, AND ININD, AND SHALL PROVIDE SHIELDING FROM SOLAR RADIATION THAT CAN CAUSE DEGRADATION OF THE MATERIAL. ADHESIVE TAPE SHALL NOT BE PERMITTED R405.4.1 CIRCULATIN6 HOT P4ATER SYSTEMS (MANDATORY). CIRGULATIN& HOT NATER SYSTEMS SHALL BE PROVIDED Y41TH AN AUTOMATIC OR READILY ACCESSIBLE MANUAL 51NITCIH THAT GAN TURN OFF THE HOT YqATER CIRCULATING PUMP ViHEN THE SYSTEM 15 NOT IN, USE R405.5 MECHANICAL VENTILATION (MANDATOR'r). THE BUILDING SHALL BE PROVIDED NITH VENTILATION THAT MEETS THE REQUIREMENTS OF THE INTERNATIONAL RESIDENTIAL CODE OR INTERNATIONAL MECHANICAL CODE, AS APPLICABLE, OR INITH OTHER APPROVED MEANS OF VENTILATION. OUTDOOR AIR INTAKES AND EXHAUSTS SHALL HAVE AUTOMATIC, OR GRAVITY AMPERS THAT CLOSE INHEN THE VENTILATION SYSTEM 15 NOT OPERATING. R405.5.1 NHOLE-HOU5E MECHANICAL VENTILATION SYSTEM FAN EFFICACY. MECHANICAL VENTILATION SYSTEM FANS SHALL MEET THE EFFICACY REQUIREMENTS OF TABLE R4o5ai. EXCEPTION: V4HERE MECHANICAL VENTILATION FANS ARE INTEGRAL TO TESTED AND LISTED HVAr_ EQUIPMENT, THEY SHALL BE POINERED BY AN ELECTRONICALLY OOMMUTATED MOTOR. R405.6 EQUIPMENT SIZING (MANDATORY). HEATING AND COOLING EQUIPMENT SHALL BE 51ZED IN ACCORDANCE INITH ACCA MANUAL 5 BASED ON 5UILDIN6 LOAD� CALCULATED IN ArrOpr>ANrF- YJTH ACCA MANUAL J OR OTHER APPROVED HEATING AND COOLING CALCULATION METHODOLOGIES. R404.1 LIGHTING EQUIPMENT (MANDATORY). A MINIMUM OF 5 r-E;1R,'_NT OF PERMANENTLY INSTALLED LAMP5 IN LIGHTING FIXTURES SHALL 13E HI6H-EFFIGAOY LAMPS. R404.1.1 LI&HTIN6 EQUIPMENT (MANDATORY). FUEL GAS L16HTIN6 SYSTEMS SHALL NOT HAVE CONTINUOUSLY 5URNIN6 PILOT LIGHTS. REVISION IMHUL ODOM I % MTE 1OLIS 4997 REGISTERED ARCHITECT RO RIGO E. NOVION WATE OF W�HINGTON L4j NOVION ;5? �__w GROUP t--' INC. 8634B 3RD AVE NW SEARE WASH 98117 PH(206)361.6133FAX361.6345 APPROVAL STAMP PROJECT LU LU t- LU X P �) ') E; E X 13) LL_ < UA -1 > LU Ck LU z --i in tj) T- U) d� LU TS C) U-) Lf) CLIENT FEB 2 1 2019 BUILDING D­ 21201b f�Zr Kn J.b Sh- A-2.0 GLAZING SNEDULE: LOCATION 51ZE AREA REMARKS FIRST FLOOR LAUNDRY 5056 1155 FIXED -SAFETY GLASS BEDROOM 5080 40.0 TOP FIXED -BOTTOM CASEMENT-555RE55 BEDROOM bobo 48.0 TOP FIXED -BOTTOM CA5EMENT-555RE55 BEDROOM 5050 24.0 FIXED-5AFE1Y C7L BEDROOM 5050 24D FIXED-5AFETY r7L BEDROOM 60511 525 DECK DOOR UNIT - SAFETY (5L RECROOM boqb 51D DECK DOOR UNIT - SAFETY 6L RECROOM 3OqO 21D FIXED-5AFETY 61 RECIROOM 3OL30 24D FIXED-5AFETY (5L REOROOM 4060 52D TOP FIXED -BOTTOM CASEMENT RECIROOM 4060 32.0 TOP FIXED -BOTTOM CASEMENT BEDROOM 5080 24D TOP FIXED -BOTTOM CA5EMENT-55,RE55 BEDROOM 3060 24D TOP FIXED -BOTTOM CA5EMENT-E6RE55 ENRTY 20bb 15D FIXED -SAFETY r7LAS5 r7ARAr7E 50141 KA TRAN50M SECOND FLOOR KITCHEN 4056 22D FIXED-5AFETY r7L o1NINr7 ROOM 15050 4b.0 TOP FIXED -BOTTOM CASEMENT DININ6 ROOM 3080 24.0 FIXED -SAFETY rvL DINN6 ROOM BOL30 24D FIXED-5AFETY 6L VININ& ROOM 608,q 52.5 DECK DOOR UNIT - SAFETY (5L LIAN6 ROOM bO5q 52.5 DECK DOOR UNIT - SAFETY (5L LIVIN6 ROOM 3080 24D FLXED-SAFETY 6L LIVIN6 ROOM 5OW .24.0 FIXED-5AFETY r7L LIVIN6 ROOM 40L30 32.0 TOP FIXED-130TTOM CASEMENT- SAFETY (7L LIVINC7 ROOM bO8q 523 DECK DOOR UNIT - SAFETY (7L L15RARY 5OL30 24D TOP FIXED -BOTTOM CASEMENT LIBRARY 5OL30 24.0 TOP FIXED -BOTTOM CASEMENT STAIRS 3OL30 24.0 FIXED STAIRS 50qb 283 FIXED STAIRS *30115 35.15 FIXED OPENIN(9 6OL30 48.0 FIXED HALLAAY 2066 15D ANNINC-5AFETY (5LA55 SUITE 505 11.5-5 FIXED 9JITE 505 11.515 FIXED Pilo 5655 11.3,75 FIXED Pilo 3655 11.515 FIXED MBATH 5056 16.5 FIXED -SAFETY CLASS MBATH 305b lbs FIXED-5AFETY 6LA55 54JITE 5056 255 FIXED SUITE 505b 253 FIXED SUITE 5056 253 FIXED SUITE 60ab 51D DECK DOOR UNIT - SAFETY 6L BATH 3053 q.15 AMININ(5-5APETY 6LA55 BATH 5053 q.15 AMINr7-5AFETY (7LA55 TOTAL r7LAZIN6 1214.25 5F OPAQUE DOOR 50HEDULE LOCATION 51ZE MANUFACTURER # REMARKS FIRST FLOOR ENTRY Bo(,a ccvr-oso THERmA-TRu FiBER(5LAsS VGEG TABLE 406�2 ENER6Y CREDITS REQUIREMENTS 2. MEDIUM DIAIELLIN& UNIT 5.5 CREDITS REOUIRED PROP05ED: OPTION CREDITS [a: EFFICIENCY BLD6 EWELOPE 0.5 50: HIGH EFFICIENCY WAO 1.0 50: EFFICIENCY NATER 14EATIWS 05 56. EFFICIENCY NATER HEATIN(7 1.5 lo. EFFICIENT 51.111-DINS, ENVELOPE IA. FRE-5CRIPTIVE COMPLIANCE 15 BASED ON TABLE R402.1.1 AITH THE FOLLOA11,15 MOVIrICATION5, VERTICAL FENESTRATION U - 0.2a FLOOR R__3a SLA13 ON 6RADE R-iO I"FIRIMETER AND UNDER ENTIRE 5LAE, EELOA &RADE 5LA5 R-10 PERIMETER AND UNDER ENTIRE SLAB So. H16H EFFICIENCY HVAC EOUIPMENT: 6A5 FURNACE NITH MINIMUM AFUE OF -14% So. EFFICIENT AATER HFATINCS SA: ALL SHOMRHEAD AND KITCHEN SINK FAUCETS INSTALLED IN THE HOUSE SHALL ISE RATED AT 1151 SPM OR LESS. ALL OTHER LA,/ATORY FAUCETS SHALL ISE RATED AT 1.0 61-M OR LE55. PROPOSED: SHOAERHEADS- 1:15 rIpm KITCHEN SINK FAUCET; 1.50 GPM BATH FAUCETS! 1.0 r1FM Sa. EFFICIENT YiATER HEATIN& 50� INATER HEATINO SYSTEM SHALL INfLUVrz ONE OF THE FOLLONIN(st GAS, PROPANE OR OIL MTER HEATER NiTH A MINIMUM FF OF OAI NATER HEATINS TO BE rA5- ON DEMAND Er OF 0.114 NA5HINSTON STATE ENER&Y rOr,>F- NOTES: BUILDIN& AIR LEAKA&E REOUIREMIENT5 To COMPLY P41TH R402.4. DUCTS SHALL BE IN ACCORDANCE AITH R403.2. MINIMUM 15% OF ALL INTERIOR LAMPS SHALL BEE HI&H EFFICACY LAMP5. ALL EXTERIOR LICHTINC, SHALL E3F_ HI&H EFFICACY LAMF5 PER R404. A RESIDENTIAL ENERSY COMPLIANCE CIERTIFICATrz COMPLYIN& INITH R401.5 15 REQUIRED TO BE COMPLETED BY THE DESION PROFE55IONAL OR BUILDER AND PERMANENTLY P05TED INITHIN 5' OF THE ELECTRICAL PANEL PRIOR TO FINAL INSPECTION. OARA&E DIAIELLIN& SEPARATION - DOOR SHALL BE 50LID rOPJ-=, MINIMUM I J" THICK-5r=Li= rLOSIN& PER R502.5.1. THE 6ARA&E SHALL BE SEPARATED FROM THE RESIDENCE BY NO LE55 THAN I" (9YP BOARD APPLIED TO THE rzpARA(5E SIDE. 6ARA&r= BENEATH HABITA5Lr= SPAOr=5 SHALL BE SEPARATED FROM ALL HABITABLE SPACES BY A MINIMUM TYPE "X" 6YPSUM Y4ALLBOARD. V414EIRZ- THrz SEPARATION 15 A FLOOR-CEILINS A55EMBLY, THE STRUCTURE SUFFORTINS THE SEPARATION SHALL BE PROTECTED BY NO Lr=s5 THAN k, &Y`F`5UM BOARD OR EQUIVALENT. ?qRAP POSTS AND BEAMS INITH '2" 6YP. PER IRC TABLE R302.6 DUCTS IN THE SARArr= AND DUCTS PENETRATIN6 THEE AALLS OR CEILIN65 5EPARATIN6 THE DINELLIN5 FROM THr= &ARA&F- SHALL BE CONSTRUCTED OF A MINIMUM No. 26 &AUC7E SHEET STEEL OR OTHER APPROVED MATERIAL AND SHALL HAVE NO OPENIN65 INTO THE- 6ARA&E PER R502.5.2 ARTIFICIAL LI&HT REQUIRED FOR HA51TABLE ROOMS NITHOUT &LAZED AREAS PROVIDINS NATURAL LlrzHT PER R505.1 EVERY DI/4ELLIN& UNIT SHALL BE PROVIDED INITH AT LEAST ONE PROSRAMMABLE THERMOSTAT FOR THE RBSULATION OF TEMPERATURFE PEP, R505A MIN. '7'-0" CEILIN& HEI&HT Rr=OUIRED FOR HA5ITA5LF_ ROOMS, HALLY4AY5, CORRIDORS, BATHROOMS, TOILET ROOMS, LAUNDRY ROOMS AND BA5EMENT5 PEP, SECTION R505 TOILET, BATH AND 5HoArzR 5PArE5 PER iRc ao-7 4 F:i&uRE: R50'7.1: PROVIDE MIN. 5 1 0" CLEAR INIDTH AND MIN. 21" CLEARENCE IN FRONT OF Y4ATr=R CLOSET; 15" SEPARATION OF NATER CLO5r=T N6 BATHTUB MEASURED I=ROM ED6E OF BATHTUB TO CL OF YiAfIER CLOSET; AND, 4" Sr=PARATION FROM ED6E OF V4ATERCLOSET TO E06E OF SINK. K4LL COVERIN65 SHALL BF_ A NONA55ORBANT SURFACE. SUCH NALL SURFACE SHALL EXTEND TO A HEI(5HT OF NOT LFESS THAN (5 Fr=ET ABOVE DRAIN IN 5HO;AIERS OR TUBS Y41TH 5HOINMRS PER R50-7.2. 5NIN6 SHONER DOOR OUTNARD I ANY NINVOY4 INITH AN OFFNING LOCATED -72" ABOVE FIN15HF-D 6RADr= AND INITHIN 24"101= THE FIN15HF-D FLOOR OP THE ROOM IT 15 LOCATED SHALL BE T=IXIEV OR HAVr= OFFNIN65 LE55 THAN 4 INCHES. I &LASS r=NrLOSL)Rr= D06RS t PANELS SHALL COMPLY NITH Tr_5T CRITERIA PoR cATrz6aRy ii UNLr=55 OTHERY415F- INDICATED IN TABLE R505.5.1. BY41NC7 DOOR OUTNARD. SAFETY ,SLAZIN5 is REauiRr=D To Br= Pr=RmANr=NTLy MARKED PER R508.1. I TYF. BEDROOM IAIINDOV4� TO COMPLY INITH R510, EMERISENCY E&Rr=55 5.-T SF MIN. NET CLEAR OPENINS: 20 INCH MIN. CLE-AR OPIEENINC7 HIDTH, 24 INCH MIN. CLEAR OPIENIN& HE16HT, AND 44 INCH MAX. SILLIHEir-SHT I IRC 510.1 - NHERE CASEMENT NINVOINS ARE USED FOR REQUIRED rESIRESS, THF=_ NINDOY4 SHOULD Br= ALLOMD TO OPEN A MINIMUM or- -io Dr=&Rrms PROM Z'LOSr=r,> 1-051TION AND IN OPEN POSITION SHALL NOT REDUCr= THr=, REQUIRED INIDTH FOR BsRESIS STAIR YqIDTHS AND HALL1Y4AY`5 SHALL HAVr= A MIN. rLr=ARANCE OF 56".INCHIEE5 PEP, IRO'REIII.6 AND R511:7 ITHE MAXIMUM RISER HEIrzHT SHALL Be -T J,,. THr= r_,REATr=5T RISER Hr=*HT SHALL NO� ExrFr=p THE SMALLEST By moRr= THAN J" PER R511.1.5.1. TlHr= MINIMUM TREAD DEPTH SHALL BE 10". THr= &REATIE-57' TREAD DEPTH SHALL NOT EXCEED THE SMALLEST BY J" Pr=R IR8 RSIL-7.5.2. STAIR Y41NDERS, SHALL HA\,r= A MIN. TREAD 12EPTH O� b" AT ANY POINT AND A MIN. TREAD DEPTH OF 10" MEASURED AT A POINT 12" FROM THE SIDE! YiHERr= THra TREADS ARE NARR6Y41ER. THE &REATEST ININDER DrEPTH AT THE 12" Y4ALKLINE SHALL NOT EXCEr=D THE SMALLEST IBY PER R511.1.5.2.1 57AIRV4AY5 SHALL BE ILLUMINATED 4 CONTROLLED 5Y 51NITCHE5 LOCATrzr,> AT E30TH TOP AND 50TTOM OP STAIRS PER R305.1 6ARA(5r = SLAB SLOPE TO DRAIN TOViARDS (SARA6E DOOR PER R56eti I &AS MRIEPLACE (DIREC+ \/r=NT) FIROVIDF b So INCH OUT51DF- COMBUSTION AIR I FREFABRICATIEED PiRIEFLIACr= To Br: Tr=5TED IN ACcORDANcr= Y41TH UL 12'7 AND SHALL I Br= INSTALLED IN ACCORDANCE INITH THE TERM5-OF THr=IR LISTIN6 AND THE MANUFACTURERS INSTRUCTIONS PER IRC R1004. HEARTH TO Br= CON5TRU I CTED OF NON COMBUSTIBLE MATERIAL. HEARTH EXTENSIONS SHALL FXTr=NP AT LEAST 16" IN f=RONT AND AT -LEAST 5 INCHES BE'Y'OND EACH SIDE OF FIREPLACE OPr=NIN,6. FOR FIREPLACE OPENIN65 (o SQUARE Fr:ET OR LAR&ER THr= HEARTH FXTEN51ONS SHALL ]=-XTr=ND AT LEAST 20 INCHr=S IN FRONT AND AT LEAST 12 INCHES BEYOND EACH SIDE OF THr= FIREPLACE OPF_NIN6 PEP, 5Rr, RIOOI.10 CLOTHES DRYER SHALL BE EXHAUSTED TO THE OU75IDF_ OF THr= BUILDING AND INDEPIEENDENT OF ALL OTHER EXHAUST SY5TEM5 PER M1502.2. THE CLOTHES, VRYrzR EXHAUST DUCT SHALL NOT FXCEr=D 55' IN LEN(STH FROM THE DRY`r=R LOCATION TO THr= EXTERIOR TERMINATION. THrz MAX. DUCT LEN&TH SHALL BE REDUCED BY 2.5 FT FOP, EACH 45-DBSRr=E BEND AND 5 IFT FOR EACH '70-DEOREF5 BEND PER TABLE MISO:2.4.4.1 MTr=P, HEATERS SHALL BE INSTALLED IN ACCORDANCE Y41TH THE MANUFACTURERS IN5TRUrTION5 PER IRC CHAP 20, 2442e, KALL KAL U-4 C A NOE KALL rCLEARLANOE KATER CL_65�� �t5 L 0'-4- NALL nALL vc AATr=P, CLOSFT OR 51DF-T KALL CLEARANCE! IN I MINIMUM FIXTURE CL RU-N 4997 REGISTERED ARCHITECT RO RIGO E. NOVION STATE OF W�HINGTON f= NOVION L!"? GROUP INC. 8634B 3RD AVE NW SEATILE WASH 98117 PH(206)361.6133FAX361.6345 APPROVAL STAMP PROJECT LLA LLI t- 111A 1= �) Q D_ =3 - X LL- LL < < LL Lu > LLI to (f) Lu is w d3 Fn' CLIENT R PH C E 0 VE D FEB 2 1 20`113 BUILDING D­ 2/2011 Rn Kn Sh-t A-2.1 SMOKE DETECTOR COMPLY INITH IRC R514 -110 VOLT- INTERCONNECTED -HARD AIRE BATTERY BACKLIP-INSTALL PER MANUF RECOMMENDATIONS > .03 > CARBON moNoxior: ALARM COMPLY NITH IRC, R515 AND UL 2054 -INTEROONNECT-HARD Y41RE BATTERY BACKUP INSTALL PER MANUF RECOMMENDATIONS EXAUST FAN ALL EXHAUST FANS TO COMPLY ViTH IFZ CHPT 15 FAN CAPABLE OF FIVE AIR CHAN&E5 PER HOUR. VENT DIRECTLY To EXTERIOR THROUr5H SMOOTH RIC710 NON -j� -- a a Xi (p Q, 43 0, > rm, E: % 0A 100 CFM MIN. INTERMITTENT OPERATION, < AB50RBF-NT DUCT5. VMINIMUM 015TANCE FROM VENT ININDOA. KITCHEN OUTSIDE BUILDIN6 AND m 70 < E: BATHROOM 50 CFM MIN. INTERMITTENT OPERATION, EXHAUST DUCTS SHALL TERMINATE THE rn IT, SHALL BE EQUIPPED YTTH BACKDRAFT DAMPERS. 9-1 AHOLE HOUSE FAN ALL VENTILATION MUST COMPLY KTH THE 2015 INTERNATIONAL RESIDENTIAL CODE. IRC M15013 ul Z 10,0 -rf! PRESCRIPTIVE METHOD -TABLE 150133(l). 4 BEDROOM -AND AS AMENDED BY TABLE MI5O'1.33(2)-5Y5TEM DE516NED > TO OPERATE CONTINUOU5LY. qO CFM MIN REQUIRED. qOrFM PANASONIC INH15PERC-REEN FV-OqVFH5 PROPOSED. 1.0 MAX 50NE RATINCS AT OY' k4ATER C7AU6E-.05 SONE5 ACTUAL TESTED. INTE(5RATED 5YSTEM-FRI5514 AIR SUPPLY THROU614 k4INVOA FORT. EACH HABITABLE SPACE TO HAVE AT LEAST ONE AINDOA NITH A ININDOY4 FORT. Z: < > > U3 �91M]501-1, FXHAJ5T5 SHALL TERMINATE omooR5 ANo NOT IN Arn, qoFFITs, Rlo6E ;p ;p A6 7a 70 70 X X < 00, VENTS, OR r-RAVC SPACE-. KITCHENS, BATHROOMS, AND LAUNDRY E*IAU5T TERMINATIONS TO EXIT THE STRUCTURE Y41TH OLMANGE5 GARASE DPELLINO SEPARATION- LF DOOR SHALL BE SOLID CORE MINIMUM 19" THICK -SE rLOBIN6 PER IIRL x >s; x A 1§ Fl, MEETIN6 SRO M1506.2: NOT LE55 THAN 5 FEET FROM PROPERTY LINES, 5 FEET FROM OpERA13Lr: AN12 NON-OpERA13LE OPENINC-5 INTO RSO2,51THE &ARASE SHALL DE SMPARATED FROM THE RESIDENCE BYNO LESS THAN I' &YP BOARD APPLIED TO THE SARA&E SIVE. SARAGE BENEATH :K e THE BUILDIN6 AND 10 FEET FROM MECHANICAL AIR INTAKES EXCEPT HHERE THE OnNINC, 15 LOCATED 5 FEET ABOVE THE AIR INTAKE. HABITABLE 5FACE5 SHALL BE SEPARATED FROM ALL HA51TABLE SPArB5 'X` OYPSUM AALLBOAJ;V. VVERE THE SEPARATION 15 SEC R402.4 BUILDIN& AIR LFAKAc7E BY A MINIMUM I- TYPE A FLOOR--EILIN5 ASSEMBLY, TH� STRUCTURE! 5UPPORTIN& THE SEPARATION Jrn FOR EACH VMLLINS UNIT, AIR LEAKACE SHALL NOT EXCEM 5 AIR CHAN6ES/ HOUR AND SHALL BE TESTED AS SUCH 5HALl. BE PROTECTED BY NO LESS THAN I" 6YPSUM BOARD OR EOUIVALIENT. ARAP POSTS AND 554t�S NITH I- SYR P5;Z IRZ TABLE R502.6 (3 A MITTEN REPORT OF THE AIR LEAKArE TEST pEWLT5,5HALL BE 51rNED By �a THE TE5TIN& PARTY AND PROVIDED To THE 5)ILDIN6 INSPECTOR, PRIOR To CALL FOR 61�r, 02406.2 - SMUIP,L�AW APPLIANCES HAVINr AN IONITION 50LRr-E 5HALL 13E M"ATED VZH r4AT THE 90L%CE � THE I�ITIM 19 AT LMAST 16' A50VE � rWM ;K z - FINAL INSFIECTION. A HAZAFWCM LOCAT A�N PROTWT f1koH AUTO IMPAOT 1 U3 m 61-01, M) ?R 0 L rl Lr_ jtp I>>- :Z: T 'n g� 68 > P70 7-2 > �-- DARm'—ZO A,, F:K -6� MW > M T3, x T, c, Am-lim-N ,� wr M:K mo > T U m W, la rkp gl� 6>2 TO p m IT m -0 ul mm Hgm qh"�m, Wril X (D / 0 TRI 24'-0" FAIRNIN05 PEVELOPMENT 15110 NE 111TH FL, 5UITE lq4 C=) c:5 NOOPINVILLE, AA IbO12 M 425.3qE55151 - OFFIOE A 425.452.2136 - FAX ARRIFICTURI ROOF PLAN LOT 3 r,RA& SPA(:�E PLAN LOT 5 REVISION DAM 49947 REGISTERED ARCHrrECT I RO RIGO �E.NOIIAON u- n., NOVION GROUP INC. 8634B 3RD AVE NW SEATU WASH 98117 PH(A)361.6133FAX361.6345 MNER/CIJEW LU tu T- Y- P Co x ti- tu -j < LL- Lo Lu :z IN (14 LL APPROVA� M�P- RECEIVED FEB 2 1 2013 BUILDING 2/2011 1/4"= 1. 0. Rn J.b # S�..t A-3.1 MAX ALLON HE16HT: 155.14 RAIL M5T: I ROOF: 152.0 SECOND FLOOR: 122.0 LIR5� FLO�R: 111.0 AVERA6E I MAX ALLON HF16HT: 155.`14 �NEST ELEVATION E-1 SOUTH ELEVATION m ROOF: 1335 SECOND FLOOR: 123.5 q4997 REGISTERED ARCHrrECT 'U RO RICO E. NOIA70N NOVION LR GROUP "-j t--) INC. 8634B 3RD AVE NW SEATTLE WASH 98117 PH(206)361.6133FAX361.6345 OWNWcum tu r 6 "U3 d�l — x LL < Lu g <) LL > OL 1.11 x- p tff-1 in cl Lu :;—r CA IL "q- 't APPROVAL STMP FEB 2 1 2019 BUILDING D.t. 2/2OIq s-1, 1/4"=I'O" D— Rn Sh-t A-4.0 FIR5T FLOO ROOF: 135.5 MAX ALLON e6HT. 135A4 EA5T ELEVATION ;.r, 5ECOND FLOOR: 125.5 — - — - — - Ila El FIR5TFLOOR: 112.6 lE NORTH ELEVATION SECON12 FLOOR: 122.0 --E95T FLOOR: I 11.0 RMSION DAM 4 49' 997 REGI—ED MC _ VS ARCHrrECT RO RIGO E. NOIAON ---'G.01 NOVION GROUP L-W INC. 8634B 3RD AVE NW SEAME WASH 98117 PH(206)361.6133FAX361.6345 CMER/CUM Lu LLI DL X < Lu 1-u i n- ==4 r- > al Ci 'cl 'cl, < IL It AP�& nAMP FEB 2 1 2019 BUILDING _2/20lq D.- Rn J.b # Sh.e A-4.1 CONSTRIZZON NOTES, PROOF CONSTRUCTION Tpo ROOF SYSTEM-CLA55 5 INSTALL FE 'ATION5 R MANUFAO. GPBOIFIr 514'T'r, PLM. EXT. APA CDX ja�� MFG TRUSSES @ 2-VO.O. - SEE FRAMING, PLAN TAPPEREP TRUSS OR 2X "RIPPERS" SLOPE TO DRAIN 114" PER rT W RND FLOOR DRAINS AITH STRAINERS - SEE DETAIL gRAIN To LOMST POINT CONNECT TO ROOF DRAIN G`r5TE DO NOT TIE INTO FOOTING DRAINS OvERFLON VRAIN5 INSTALL 2" ABOVE ROOF SURPACE R-55 INSULATION- 5/5" PLASTERBOARD SIM STRUCTURAL PLANS FOR ALL FRAMING INFORMATION EKMRIOR KALL CIM7JYIIQN KWIE SIGNS TYVIEK HOMERW 1/2' 'DX FM- �, 055 OFT. e 2X6 ST"5 @ lbw 0 IZ-21 BAIT IP5ULATION KRAFr PAPER AARM SIDE 1/2. GAS. frM KALL SHEATH NAILIN& - UPD) 5d : VOL. ES76E NAIL bd 12'OL.FIELDNAIL (ALL B(rER OR YEAT�M EXPOSED aFFACES SMALL HAVE NEA1�lfft RMISTIVE BARMER EXTERIOR OMINS5 SHALL BE PLA%W IN A MARiER TO MAKE THEM MATERPROOf) ZVTMOR JOIWS AT OPEN N66 541 AS DOORS. KIM SETMEN MILL AND ROOF = BE WAM &MLPX LIMIT AIR LEAKASE FIR WIX, 902.43) STAIR CONSTRUCTION I Y2" PIPE HANDRAIL. HANORAIL5 ADJAOE� SPACE or NOT LESS THAN 1 YY BI I HANDRAILS (SEE DETAIL SISLON. INTERIOR RAIL TO BE C-ONTINUOU5 FOR TH rL:&HT, FROM A POINT DIRECTLY ABO FL &HT TO A Po NT DIRECTLY ABOVE LOP HANDRAIL ENDS SHALL Be RETURNED OR POSTS OP. SAFETY TERMINALS. NAMPRAI L HEIGHT, MEASURED VIERTICALL: ADJOINING THE 11READ NOSING, OR FINISH 5SALI- BE NOT LESS THAN 54 INCHES AND W-W MIN. MEAD CLEARANCE MEASURED N, 5LOPFD PLANE AP-41ININO THE TREAD Nc SURFACE Or THE LANDING OR PLATFORM S.5XII Y400D TREAD- ATTACH TO GILES rA ANGLE. OPEN R SER 5 '"If SL0 CARRIAr r (EACH SIDE) ATTAC SIMPSON CITS CONCEALED HANGER. (rRAM 5FAC.15) 5/4" wX Tso PLYNOOD (SUPS 4 RAIL) 9 r _L-OOR JOISTS. - SEE FRAMING PI.AN R-56 11SULATI011 III I O"r =p . 5TEMI 2X& PRESSURE TREATED PLATE 515XIO ANCHOR SOLT P41TH AASHISR 5XIS, 12" FROM CORNER MOOD IN CONTACT W CONCRETE TO BE r'pg����CTION 4 A &X& Y4 AX1.4 MM LAP ONE MESH VAPOR 51 MIL VISGUEEN) 6" MIN. GRAVEL OVE STRUCTURAL PILL PROVIDE CONTROL JOINTS 4" RJND PLASTIC, T16HT LINE DOVINSPOUT DRAIN. TIGHT LINE SEFARAT 4" RND PERr. PLASTIC FOOTING DRAIN A CLOTH LINE IN GRAVEL TIGHT LINE INIlIB-- APPROVED DISCHARGE 12 FT. C—T m i� -LID TO � LO�T -INT -K—T — Im TO IPdP SETION A -A SCALE: o.. 49947 REGISTERED RC __ ARCHrrECT RO RIGO E. NOWN O� �WMHINMN NOVION GROUP INC. 86340 3RDAVE NW SEATTLE WASH 98117 PH(206)361.6133FAX361.6345 OWNEVC— Lu x C) ItY IL lu La 7;; -2= w FEB 2 1 2019 BUILDING J.b # s— A-5.0 STAIR CONSTRUCTION-1 1.5" 1.5" PROVIDE SOLID BI AT KAL-5 FOR PROPER ATTACH OF RAILIN6 lo" SLOCK AS RBQV DE MIN. 5/5' TYPE SYPA USABLE ENCLOSED SFACZ UNDER STAIRS AT SAWS qO# FELT SIMPSON AINSLIE! BRACKET STAIR CONSTRUCTION I IJT PIPE HANDRAIL MOUNT I I/TFROM NALL RAIL TO BE WNTIRM FOR THE FULL LENSTH OF TIE FL16+17, FROM A POINT DIRECTLY ABOVE THE TOP RIVER OF THE FL16HT TO A POINT DIRE' TLY A50VE THE LONEST RISER OF THE FLI&HT. HANDRAIL ENDS SHALL BE RETURNED OR SHALL TERMINATE IN WOEL "IS OR SAFETY TERMINALS. V-VMIN. HEAD CLEARANCE. 1 1/4' PLYHOOD' TREAD 6LUE 5/4- PLYAOOD RISER BLUE Li 2X12 MIMERS 0 12" IX12 APRON MMlN.9Vb'6YPA USABLE ENCLOSED SPACE UNDER STAIRS SIMPSON LS ANS115IS) 2X4 5TiFFNER OPENINI FOR REOU RED GUARDS ON THE IR W)E5 OF STAIR TREADS. OPENING BETVAEEN TREA175 SHALL NOT ALLOY4 A INC,HES To PASS THROUGH. REFER TO 5TRLrTURAL DRANNSS FOR FRAMIN' REOUIRMIENTS AND DETAILS PER R302.11 PROVIDE FIRMISLOOKIM 5ETHSEN STAR STRIN&ERS AT THE TOP AND BOTTOM OF THE RUN SIMPSON HUW 210 HANI CONCRETE STAIR ON GRADE 5pC FANDRAL PER ' 11/2'PIPEPAL W ABOVE NOSM 4" SLA13 ON GRAD 6" RMISR. 12" B.A. NOSE BAIRS(TYP) 4'MIN SLAB THICK 11119 11 STAIR CONSTRUCTION-2 11 STAIR CONSTRUCTION I Y2'PIFE HANDRAIL. HANDRAIL$ ADdACENT TO A NAU SHAI.L HAVE A SPACE OF NOT LESS THAN I VIBEMEEN THE KALL AND THE HANDRAIL5 (50 VETA L BELON. =OR RAIL TO BE CONTINUOUS FOR THE FULL LEOT14 OF THE FLIGHT, FROM A POINT DIRECTLY ABOVE THE TOP RISER or THE FUSHT TO A POINT DIRECTLY ABOVE LONEST RISER OF THE FLI&HT. HANDRAIL ENDS SHALL BE RETURNED OR SHALL TERMINATE IN NEIEL POSTS OR SAFETY TERMINALS. HANDRAIL HE16W, MEASURED VERTICALLY FROM THE SLOPED PLANE A=INN6 THE TREAD NOSIN6, OR FIN SH SURFACE OF RAMP SLOPE, SHALL I BE NOT LESS THAN a4 INCHES kV NOT MORE THAN 58 INCHES. V-D'IMIN, HEAD CLEARANCE MEASURED VERTICALLY FROM THE SLOPED PLANE ADJOININS THE TREAD KOM OR FROM THE FLOOR SURFACE OF THE LANVIN& OR PLATFORM. 9SX11 P4000 TREA17- ATTACH TO 61-5 CARRIA&E 11IT14 SIMPSON TAIOZ ANSLE. OPEN RISER 5SX11 ( LI3 CARRIME OCH BIZ ATTACH AT TOP AITH SIMF50N CM CONCEALED HANSEK WARD ATTACHMENT TO COMFL'r KITH TABILLE R501.5 GUARDS AN" HANDRAILS SHALL INITHSTAND A 200*1 HOlIZiDNTA- FORCE. .UAF. INI ILL. COMPONENT SHALL NITHSTAND A 50# HORIZ APPLIED NORMAL LOAD. le �;�Zz REGUIRUED WARDS SHALL NOT HAVE OPENINGS FROM THE INALKINS, WIRFACE 70 THE REQUIRED GUARD HEIGHT THAT ALLON PASSAGE Or A SPHERE 4 INI IN DIAMETER STAIR HIDT�r. AID RALLMY5 SHALL HAVE A MIN. CLEWNCE OF 06' INCHES PER SR0 R311h AND R5111 MAX 12"O'VERTICAL R15E PER RSII.1 THE MAXIMUM R15ER HEI&HT SKALL BE 11'. THE GREATEST RISER HEIGHT SHALL NOT MEW THE SMALLEST BY MORE THAN P FER 5RC P311.1.4.1. THE MIRKM TREAD DEPTH SHALL BE 10'. THE SREATE5T TREAD DEPTH 5HALL NOT EXCEED THE SMALLEST BY k. STAIR Y41NDERS SKALL HAVE A M N. TREAD DEPTH OF 6' AT ANY POINT AND A MIN. TREAD DEPTH OF IO'M!-ASlJREv AT A POINT 12' FROM THE SIDE NERE THE TREADS ARE NARROVOt THE GREA)IS.T ANDER DEPTH AT THE IT 4ALK-INE SHALL NOT EXCEED THE SMALLEST BY J'PER SRZ R311.142 STARMY5 SANILL BE ILLUMINATED 4 CONTROLLED BY SAITCHES LOCATED AT BOT14 TOP *0 W70H OF STAIRS PER RL R3.03.6 4 RwSh.I FOUND/SLAB CONST. - GARAGE W EXTERIOR WALLS, WOOD FRAME 16A 912 W. NP 8105 1 EXTERIOR 51DE: O�. IW' 48" .1d. 51W M.� .1 W GYPSUM NALLBOARD, SYP5UM SHEATHING, row SIUDS 'd loll- -1,1,1, 0 p— EXWrIcr ,I.ddN t� la� �tW�.d �,rmqh 6.thlq to =SIDE 'd, ==. blld r m I �Nr"" 'th 6d ,oatad .11/5 A.�, 1/4" hwds, 7,Ill (L=l2AoW`Nq6l)S Thl,W- V"?.� m I f " 5510 (UL R3501-41,46,4-11-65, T UL D" -; UL R11142q,71-22-10, UIL V..iq, UBI4) DECK RAIL CONSTRUCTION RUEOUIREV r.UAPJ;5 SHALL NOT HAVE OPENINGS FROM THE AALKINS SURrA0E TO THE Rr:GUIFJ!D CUAFD IGHT THAT ALLON PASSAGE Or A REFER TO STRUCTURAL FOR SCREN SPHE INCHES IN DIAMETER. 51RACING, AND CONNIBOTION INFORMATION FOR REWIRED GUARDS SHALL NOT ALLOIN A SPHERE 4 INCHES TO I -ASS THROUGH. INPILL F ETAL lu MOUNT DOOR ON POST 2>(O PRZS TREAT PLATE. rL.151-4 AS —rrKVX5' YV H55 2"X2`Xj" rp �OVIVS BILL I -AN MOUNT RAIL ON (A)J"o X 4 �'LAG ECREA bXb PRESS.TPEAT 5,S, IV MFM13EFZ PLATE. AA17ER PROD AS Rzo -IA ell!12 4 GASKET FLOOR DRAIN 11 RE l;;. �To rRUrTU FOR RAIL ATTACW 5C MA 5PAVINS AID WNNECTION INFORMATION METAL DRIP ED PRIMED ATTH 20 6ACOFLEX 66 'YSTEM 6X SOLID BLOCK OR '015T AT RALINS CONNECTIONS x 2X4- IFE MOD TLE MCK11,16 INSTALL MR MANUFAC. SPECIFICATIONS LEVEL PEDESTAL SYSTEM TFO ROOFINO SYS ACOFLEX 05 TAPE INSTALL PER MAMMA(, SPECIFICATIONS AULK V4'T#6 P-00. EXT. APA A0 W 2X SLEEPER FOR SIM 91.01FE TO MIN 1/4" PER PT. JOINT 2(JIOIST5 @ 161 OL. SLOPE TO DRAIN 1/4'PER FT. :I/2XS TUBE RAIL, YEDED CONNECT. V2XS TUBE P05T @ IV O.C. MAX. IB" FROM CORNERS. (qO X 4 � LA6 SCREM INTO SOLID MEMBER PROVIDE SCRIN CAULCKIN& PRIOR TO I*TALLIN6 IN SLIS+TLY UNDERSIZED SCREA HOLES BASE PLATE CASKET LYAOCV HEAVY MUSS FLASH CAP OVER SLOPISO SPACER V RHO FLOOR MINS KITH STRAINERS MIN DRAIN TO BE LOVIE5T POINT CONNECT To ROOF DRAIN SYSTEM DO NOT TIE INTO FOOTINr DRAIN5 MIN - PLYWOP 4'Xb" OVERFLON SCUPPERS, INSTALL 2' ABOVE PECK SURFACE NOT TO VALE &ArOFLrX MCK FABRICATED MSTAL SCUPPER SACOFLEX " TAPE 5Y5T`M SAC,OFLEX MCK COATIN& 6ACOFLEX 66 TAPE 5Y5TEM RIN6 SHANK NAILS METAL. Sl-UPFER. INSTALL SOJFPER TABOVE DRAIN FOOTING / WALL CON.RUCTION ST EXTEI JOINTS AT OPENINGS SUCH AS DOM, KNOCKS, BETHEMN KALLS AID FOUNDATION, BETINEEN KAU AND ROOF, SKALL BE 515N.VD, CAULKED, SA5KZTEV OF. HATHERSTRIPPED TO LIMIT AIR LEAKASE fffi77 PER PGEC 502 4B CRAPt! PACE Z 6 MIL POLYT TillrLENE VAPOR fMrAMZR_ 11 M ROOF CONSTRUCTION ROOF FL&�dINS PROVIDE VALLEY FLASHINS PER 5114 405.2b.5 AND FLASHINS AT ROOF JMIVPa NTH VERTICAL SURFACES. Fez SR6 III 2-94- IFE �000 TILE- ITRUCTION LEVEL FEDEBTAL SYSTEM BYSTEM-01 ASS 5 INSTALL PER MANUPAC' SPECIFICATIONS 514- T46 FiW. EXT. APA COX SLOPE JOI a 16, O,C..- SEE FRAMINS MRIPq!W=P!T0VRAI 2X I"' -- DETAIL MIN TO BE LOAMT POINT CONNECT To — — — CCITT METAL Pu AL ROOF DRAIN SYSTEM CLOSURE STRIP 00 NOTTIE 11 _O.. .1. r OVERFLOA DRAINS INSTALL 2' ABOVE SURFACE R-38 INSULATION &NE SEE STRU011RAL PLANS FOR ALL FRAMNS INFORMATION 4 NAILIK6 RWUJREKNTS RDOF SHEATH 50LID ELOCKINS AMRE � IS CFEA UNDERSIDE OF EAVES RAIL OF THIS FALRENTMIN S' OF PROPERTY I -I YY LINE _ _ P,AFTER BAY �Vlm 21 . R aEME r _1 TYPICALL a I_ Vwomm BE TRU55 BLOCKIW T� 'm a__ NTH Ill. MRS SIHEATHIN& VENT ARZA- 2*= 12 NTH I.. MIH TO ROOF CONSTRUC FLOORIWALL CONSTRUCTION "DINS APPRDVED COWTiON-RESISTANT PLASHIN& EXTERIOR M-LS 5HALL USE M K TYVIK Hommmw FER RIOSA HEATHERIZATION SYSTEM la COX PA. (a, OSS) TYVBK COMMERCIALINRAP 2X& STUDS @ 161 O.C. ALL EXnRIOR OMIN65 SHALL BE FLASHED IN TY`VBK CONTRACTOR TAPE AT R-21 BATT INSULATION A MANNER To MAKE THEM AATERFROOF PER OVERLAPPED SEAMS KRAFT PAPER nARm SIDE IRC 103.4 NINPOYG AV DOOR OPENINS6 1: 1 BE V7 &AB. NRAPPED, CAULKED AND FLASHE 1) PER — EXTERIOR AINDON AND DOOR OPENINS6 LIVER TYVEK INSTALLATION WIDELINE! li�— INS - UNO THE DOS OF MAWNARY, AOOD COPINSS AND . . ft� SILLS. Ed o IT OZ. FIELD KAIL CONTINUOUSLY ABOVE ALL FROXITING MOD TRIM. ALL EXTERIOR HEATHER EXPOSED EXTERJOR PORCHES, DECK5 OR STAIRS SURFACES SHALL 14AVE MATHER ATTACH TO A KAL. OR PLO " FLO RESISTIVE BARRIER PER SIM R105.2. MOD FRAME CONSTRICTION AT KALL AND ROOF 1—TIO AT ALL EXTERIOR OFENIN&S SHALL BE IN &UTTERS. MASHED IN A MANNER TO MAKE THEM KATERPROOF PER IRC 103.4 Y41NPOM AND DOCORS, TO BE NET ' D I' EXTERIOR JOINT5 AT OPENN&S SUOH AS MANUFACTURERSSMnCIFICA DOORS, Y41NXYG WrAEBN KALLS AND FOUNDATION, 5ETYM KALL AND ROOF, FINISH FLOCRINS SH,-L- BE 5EALM, CAULKED, 6ASKEKED 5/4'GPX T0 PLYMOD OLUE 4 NAIQ OR AEATHEIRSTRIPPED TO LIMIT AIR $PAN RATE 45)24 LEAKASE PER SEC 50243 2XV V0.0 - SEE FRAM No" R-33 BATT iN5ULATION - KRAFT PAPER MARM SIM OVER UNHEATED 1/2'GM REFER TO STRUCTURAL DRANNS6 FOR SHEAR NAILIN5 RMIREMENTSAND SHEAR!"XIL CONNECTIONS FOOTING/ WALL CONSTRUCTION CONCRETE SLAB A 6Xh A IAXt.4 LAP ONE MESH VAPOR BARRIER e MIN. &RAVEL PROVIDE CONTROL JOINT5 4'RND "TIC, TINT LINE DOVOLq'CVr DRAIN. T1644T LINE SEPARATE TO APPROVED D1504AR6E 4' W PEW. "TIC. FOOTING DRAIN AS SHOAN MAP IN FILTER CLOTH, LAdD IN 6RAVEL. T16K LINE INDEPENDENT OF 0 0 OTHER DRA H5 TO APPROVED DISCRARSE .............. 0 REFER TO STR14TURAL DRANNS5 FOR 5HEM NAILINSAMPORA61! RESUIREMENTS I FOUNDATION DETAILS R-10 M61D INSULATON- 24'AIDTH PERIWrl-:R $ UNDER ENTIRE SLAB �?2 F,t —SION mu 4 997 44'17 REGI—ED ARCHITECT T` R0 RIGO E. NOMON NOVION GROUP INC. 8634B 3RD AVE NW SEATILE WASH 98117 PH(206)361.6133FAX361,6345 OWNM/CUBT 4- X LL ck 'r- Ck Lu 51 ui ui ILL So- 4t I AppIuw& nmp Pil C-CEOVED FEB 2 1 2019 i3UILDING D- 2/201� s.j. 7�# s— D-1.0 SHEARWALL SCHEDULE SWEXP Notes apply as called out in table below. , Anchor bolts embedded at least 7", or expansion anchors embedded at leastV. See detail SWR 2 *MASAP can be Installed instead of sill bolts with washers. When replacing 1/2"0 sill bolts use 7-10dxllh" nails (minimum nailing) and when replacing 51s"O sill bolts use 9-10*11h" nails (maximum nailing). 3 See detail SWIF. Connections vary depending on condition. 3a Substitute 16d toe nails @ 8"m for *A35. 4 See detail SWR. 5 See data! SWEL 6 Abutting panel edges require a 2-2x (lamination connection same as WALL BASE PLATE), 3x� or greater stud. 7 See detail DSW. 8 The plate washer shall extend to within 1/?of the edge of the bottom plate that receives the sheathing or rim. SHEAR FLOW CONNECTIONS SPACING EWALL SHEATHING SILL -TO - FLOOR -TO -1 ROOF_TO WALL BASE PLATE CALL CALL LL SHEATHING EDGE FOUNDATION 1, 2 SIU_ & WALL] 3 WALL 4 3 OUT CUT OUT THICKNESS I NAILS 5/81V @ 6U'oc or *A35 @ *H1 @ 16d @ 10"oc A 6 61 7/16- 8d @ 6"oc 1/2"0 0 60". 48?'oc 3a 24'm 4a -9/8,g @ 49'm or *A35 0 *LS50 @ 16d @,Voc B 4 7116' Sol @ 4"oc 1/2"0 C& 12"OC IV'oc 2,Voc 4b [44, 5/8'10 @ 3Zoc or ,A35 @ *LS50 @ 16cl @ 3"oc C 3 7/16" 6 8d 0 3�oc 1/2"0 0 24`0C 8 16,oc 16Poic 4b IWO @ 2,V'oc or #A35 @ #LS50 @ 16d @ 2"oc D 2 7/16" 6 Eld @ 2"oc '/2"0 0 16"m 8 12"m 127oc 4b 5/8"0 @ I.Toc or *A35 @D #LS50 0 7/16- both Ed @,Vloc 1/2"0 @ 12"M 8 8"oc 8"cx, 41, sides 6,7 HOLDOWN SCHEDULE 1 Deepen the foundation as needed to provide the required holdown embedment Into the foundation wall. See Detail MHE 2 Fasten to the end framing members ofthe shearwall, u.n.o. 3 FOUNDATION ANCHOR may be extended with threaded rod and coupler as required. 4 Pnouicle the minimum embedment and edge distances specified by the manufacturer. 5 Attach to (2) 2x studs minimum (lamination connection same as WALL BASE PLATE; stagger nails), u.n.oi A I;— &t.11 NON fri, installation. HOLDOWN I STRAP I., I., , . FASTENERS 5 FOUNDATION ANCHOR 1, 3, 4, 6 COMMENTS *STHD14/14RJ 30-16d sinker N/A OHM 26- #SD #10x21/2 N/A 2-2x4 min post *HDU8-SDS2.S 20- *SDS1Ax21/i *SB7/8x24 6x6 Min Post UA.O. *HDU1I-SDS2.S 30- #SDSIAX21h VVIT.R. 16x8 Min Post U.N.O. See detail RFh *MSTC40 36-16d sinker N/A qual number of nall tobothconnected leelements *MSTC52 44-16d sinker N/A Jeclual number of -nails to both connected elements WARNING IGENERAL STRUCTURAL NOTES THIS IS INTENDED TO DRAW ATTENTION TO FREQUENTLY EXPERIENCED DIFFICULTIES IN CONSTRUCTION: LONG LEAD ITEMS 0 DIFFICU FIELD RETROFITS 0 LIMITED OPTIONS FOR RETROFITS CODE All condibons, materials and construction shall odrifiamn to the code specified in the DESIGN CRITERIA, or other codes required by the governing jurisdiction. PROTECTION Through maintenance and current best practices, provide a building envelope that will preserve the integrity of the structure throughout its lifetime. INSPECTIONS Notify Building Department for Inspections required by local jurisdiction. DEFERRED SUBMrffA Deferred submittal items shall be proAded to the engineer of record for review for compatibility with the primary structural design. Pre-fabriciited Steel stairs Bearing capacity of soil shall be per DESIGN CRITERIA or greater. Footing shall bear on solid undisturbed level soil devoid of any organic material and below indicated frost line. COMPACTEDIFIL shall consist of predominately Well -Graded, granular soil, free of organic material and debris. Fill should be placed in maximum V' loose lifts and compacted to a minimum of 95 percent of the maximum density at optimum moisture content determined by ASTM D-1557 test procedures. BACKS]. shall be free draining and without organic material and debris from one of the following soil classes SM-SC, SM, SP, SW, GC, GM, GP, and GW. FOUNDATIONS AND RETARMIG WAL Extend footings to undisturbed bearing soil. Do not backfill until all slabs and/or horizontal diaphragms are constructed, otherwise provide temporary bracing to resist movement. There shall be no machine compaction on the retaining side of the structure for a distance equivalent to 2/3rds the wall height. See applicable detall(s): FrG SILL PLA Use pressure treated 2x plates u.n.o. Embed anchor bolts at least 7" (expansion anchors 4"). Use Tx]l'�KO.229" washers. There shall be a minimum of two bolts per piece spaced not more than 6 feet apart, with one bolt located not more than 12" or less than 4" from each end of each piece. CONCRETE fc = 3000 psi minimum for environmental exposure (2500 psi used in structural design, or unless greater psi indicated on the plans). 5 1/2 sacks of cement per cubic yard of concrete and a maximum of 6 gallons of water per 94 It, sack of cement. Maximum slump is 4". Segregation of materials shall be through proper handling and placement. REDFORC]INGSTEE #4 bars and larger shall be Grade 60 deformed bars, and #3 bars shall be Grade 40 (u.n.o.), in accordance with ASTM A-615. Lap splices 32 bar diameters u.n.o. Welded wine fabric shall conform to ASTM A-185 and shall be 6x6 - W1.4xW1.4. Lap one full mesh at splices. CLEARODEV 3" cir when cast against Earth and 2" or in all other locations, u.n.o. See applicable detaii(s): RE FOOTIENG DRABAGE Footing drainage per IBC section 1805.4.2 & IRC section R405.1. WOOD FRAM in contact with concrete or masonry, or exposed to weather, shall be pressure treated. Numbers in parenthesis, IE (1-1), refer to ocrresponding engineering miculations. CONNECTORS AND FASTEME Fasteners, including nuts and washers, and connectors in contact with pressure treated wood shall be hot -dipped zinc -coated galvanized. EXCEPTION: Plain carbon steel fasteners, including nuts and washers, in SBX/DGr and zinc borate preservative treated wood in an interior, dry environment shall be permitted. SOLEOSAWNLUMBE shall meet the following minimum grades (u.n.o.) conforming to "WWPA GRADING RULES FOR WESTERN WMBER", latest edition; BEAMS, POSTS, RAFHRS, 6X and wider DF#1 4X DF#2 2x 10 and greater DF#2 2x 8 and smaller HF#2 WALL HF#2 EPIGINEERED shall meet the following minimum properties: Callo E x 106 (psi) Fb (psi) Fc mr (psi) FC mm (psi Fv (us!) LVL 2.OE 2600 750 750 285 LSL I.SSE 1900 20SO 900 310 PSL 2.2E 2900 2900 625 290 Engineered wood products shall be protected from moisture to preserve their structural Integrity. Provide temporary bracing to avoid permanent cleflections resulting from drying under construction deadloads. I-301STS Connect I -joist to plate using one 10d (0.131" x 3") nail on each side of bottom flange; drive nails at an agle at least 11/2" from end. Connect 13/4" LSL rim to I -joists with one 10d (0.131" x 3") nail into top and bottom flange. Full -depth blocking between joists over shearwalls shall be 13/4" min LSL. TRUSS Manufactured trusses are a deferred Submittal item designed per CODE section 2303.4 and shall be designed for all loads and load combinations per the 0001!. All connections per manufacturer, u.n.o. If truss layout is changed by manufacturer, please notify this office. See applicable detail(s): GEB Trusses which require drag forces shall be designed for a drag force of: Indicated on the plan WALL FRAMIM & BEARING Walls shall be 2x studs at 16"oc max with double 2x top plate, and 2x base plate (exterior walls shall be 2x6 u.n.o. Ek interior walls shall be 2x4 u.n.o.). Block all supports solid to the foundation. See applicable cletail(s): BHS TPS BEAM PENETRA71ONS Allowable beam penetrations shall be made in the middle third of the span and the middle third of the depth. Contact this office for any penetration outside the allowable area. See applicable cletail(s): 1311, POF N.T.S. WNG GENERAL STRUCTURAL NOTES continued WOOD STRUCTURAL PA NIELS shall meet the performance standards of the "APA" DOC PSI and PS2 for their intended application (group 5 species not allowed). SHEARWALLS are indicated on the plans with a bold dashed line and labeled SW. The following letter designation refers to the Shearwall Schedule's SHEAR FLOW CONNECTIONS / SPACING table, and the number designation refers to the WALL SHEATHING table. Multiple combinations of letter and number designations may be present. Wall Line numbers, shown inside triangles, refer to corresponding engineering calculations. Attach rated sheathing (indicated below) to 2x min STUDS spaced no more than 16"oc, u.n.o. See Shearwall Schedule for minimum thickness and fasteners (thickness at point of fastened edges governs shear values). All panel edges shall be blocked. Nail Intermediate supports @ 12"oc. Do not penetrate nailspastflush. Install squash blocks under the ends of all shearwalls where the framing below does not provide full bearing. Construct cripple walls same as the shearwall above, and gable -ends same as the shearwall below. Rated sheathing: 7/16" OSB rated with a 24/16 span rating. I/Z'CD with a 32/16 span rating. See applicable detaii(s): SWE ROOFDIAPHRAGM stall either OSB or CD sheathing: 7/16" OSB rated sheathing with a 24/16 span rating; panel clips required when spacing is greater than 29'oc. 1/2!'CD rated sheathing with a 32/16 span rating. Use 8' x 4' panels with long dimension perpendicular across Supporting framing. Stagger panel rows half the long dimension. Nail all boundaries and supported edges with 8d @ 6"oc and interior supports with 8d @ 121oc, blocking not required u.n.o. ROM -TOP DECK DLAPHRAGM Install minimum 23/32" rated Sturd-I-Floor T&G with a 24oc span rating Use & xV panels with long dimension perpendicular across supporting framing. Stagger panel rows half the long dimension. Glue and nail all boundaries and supported edges with 10d @ 6"oc and interior supports with 10d @ 12" oc, blocking not required u.n.o. See applicable detail(s): CSP DrAPHRAG4 Install minimum 23/3Z' rated Sturd-I-Floor T&G with a 24oc span rating. Use & x 4' panels with long dimension perpendicular across supporting framing. Stagger panel rows half the long dimension. Glue and nail all boundaries and supported edges with Ii @ 6"oc and interior supports with 10d @ 12" oc, Mocking not required u.n.o. COLLECTS Diaphragms shall be nalled continuously to drag struts, drag trusses and other collector elements at boundary spacing, u.n.o. See applicable cletail(s): DTC CS STRUCTtIRALSTEE shall meet the following minimum properties: Section Grade Fv(kl Fu(ks!) E.10(osi) W-Shapes ASTM A992 so 65 29 HSS Shapes ASTM A500 46 58 29 Plate$ ASTM A36 36 58 29 Bolts ASTM A325 Anchor Bolts ASTM A307 All welding shall conform to the latest edition of the A.W.S. DIA "Structural Welding Code". All welds shall be 3/16'minimum u.n.o. Wel(fing electrodes shall be E70XX low hydrogen electrodes for maual shielded metal -arc welding or equal electrode for other welding processes. Welded joints shall conform to A.W.S. prequallfied joint details for welded construction. All welding shall be performed by W.A.BO. cerdfled welders. Fabricators of steel items shall be approved per section 1704.2.2 of the CODE. All structural steel not embedded in concrete or masonry shall receive one coat of an approved primer after fabrication and one finish coat after erection. Field burning of holes Is not allowed without approval and/or inspection. Provide washers on all bolted connections. Structural bolts shall be A325-X Typical U.N.O. A490-X bolts fully tensioned shall be used as specified in details. CONNECTIONS and fasteners shall be per CODE Table 2304.10.1 u.n.o. The symbol, "*ff, indicates a hardware connector from the most current Simpson Strong -Tie Catalog. Hardware with equivilent or greater capacities from other manufacturers may be substituted, example you can use LISPs Dual Specification Chart to make an equivilent or greater capacity selection. Install per the manufacturer instructions. Fasteners and hardware in contact with pressure treated wood shall be hDt-dipped zinc -coated galvanized. NA All nalls shall be "Standard Common" size per the latest edition of the National Design Specification for Wood Construction INDS) u.n.o. See applicable detail: INS HOEDOWNS See the HOLDOWN SCHEDULE. See applicable detall(s): HONE HOC POSTCAP Provide a post cap on isolated columns that most nearly matches the actual member size(s) U.N.O. Each connection shall have a minimum of (3)10d to the post and (3)10d to the beam. HANGE Model numbers will be specified on the plans for conditions that require more than minimum capacity, otherwise see CONNECTIONS When a hanger is not specified on the plans, use any size specific model number that fits that member. Always use MAX NAILING. Hanger to match member size. Notching or shimming of beam not allowed unless specified. JCBSrrE SA Sound Structural Solutions Inc has not been retained or compensated to provide design and/or construction review services related to the contractor's safety precautions or to means, methods, techniques, sequences or procedures for the contractor to perform their work. The undertaking of periodic site visits by the ENGINEER shall not be construed as supervision of actual construction and not make him responsible for providing a safe place for the performance of work by the contractor, subcontractors, suppliers or their employees, or for acoa�, visits, use work travel, or occupancy by arty person. OWNERSHIP OF: DOCUMENTS These drawings and calculations are the intellectual property of Sound Structural Solutions Inc. These drawings may not be used in whole or in part by any person without permission of Sound Structural Solutions Inc. MISCELLANEO The contractor shall verify dimensions and conditions at job site. The contractor shall provide temporary bracing as required until all permanent connections and stiffenings have been installed. Do not scale drawings. Pre -fabricated Items to be handled and Installed per manufacturer's recommendations. PLAN INSTRUCTIONS READ THIS FIRST These plans are organized so that more detailed or specific information is found in the same way by following the direction shown below: GENERAL STRUCTURAL NOTES SCHEDULES, DETAILS and PLANS Will often refer to GENERAL STRUCTURAL NOTES for mom specific information. SCHEDULES �DErAILS and PLANS will often refer to GENERAL STRUCTURAL NOTES and SCHEDULES for more specific information. DETAILS �PLANS will often refer to GENERAL STRUCTURAL NOTES, SCHEDULES and DETAILS for more spedfic information. PLANS See the SYMBOL LEWD as well as ABREVJATIONS A No ACRONYMS for other additional information used on the PLANS. The term, TYPICAL (or TYP), used with a detail callout or plan note, Indicates that the Information specified shall apply in all similar conditions. IF YOU HA VFA N Y QUES77ONS OR CONCERNS CON TA C7- US IMMEDIA TEL Y! We can be reached immediately by.phone: (425) 778-1023 For less pressing questions, email us: ihbox@ssseng.com Please help us get to your plans by having thisjob.number handy: s1811020 ABBREVIATIONS AND ACRONYMS AgV ABOVE E.S. EACH SIDE, O.C. ON CENTER A.R ANCHOR BOLT E.W. EACH WAY P.T. PRESSURE TREATED ELW BELOW EA EACH REINIF REINFORCEMENT 13LK BLOCK E.N. EDGE NAILING REQD REQUIRED EUKG BLOCKING EMBED EMBEDMENT SCHED SCHEDULE B.N. BOUNDARY NAILING EXIST EXISTING SIM SIMILAR Errm BOTTOM FDN FOUNDATION STD STANDARD BRG BEARING FIR FLOOR STRUCT STRUCTURAL, EETWN BETWEEN FRMG FRAMING sw SHEARWALL CUR CLEAR FTG FOOTING THRU THROUGH CLTR COLLECTOR G.T. GIRDER TRUSS TYP TYPICAL CONC CONCRETE GR GRADE U.N.C. UNLESS NOTED CONN CONNECTION HORIZ HORIZONTAL # OTHERWISE CONT CONTINUOUS MAX MAXIMUM VERT VERTICAL cTR CENTER MFG MANUFACTURED W/ WITH DBL DOUBLE MIN MINIMUM W/o WITHOUT DET DETAIL o/ OVER W.W.F. WELDED WIRE FABRIC E.E. EACH END 0C ON CENTER DESIGN CRITERIA �o", Governing Cod� CSB� RJ�I,C�teg.,y II Vfind Design Data lBasic Wind Speed (3 sec gust) mph 110 1 Internal Pressure Coefficient +/_ 0.1� ISurfaae Roughness Topographic Factor. K� 1.0 JWInd Exposure Category iWind Importance Factor, 1 1.0 Earthquake Design Data Seismic Importance Factor, 1. 1.00 Seismic Force Resisting System Table 12.2-1: A-15 Site Classification D Response Modification Factor, R 1 6.5 Transverse 6.5 Lnginidinal Short Period Acceleration, S, 1,267 I -Second Acceleration, S� 2010 Equiv. Lateral Force Procedure Seismic Design Category _2�� D Seismic Response Coefficient, C, 0.130 Train e 1 0.130 Lorgibudiml Spectral Response Coefficient, Sps 0.845 Spectral Response Coefficient, Sp� 0.497 — Seismic Base Shear, V 1 20475 lbs, Gravity Load Data Roofs: loads, are psf Dead Uve Snow Trusses (flat) .Occuplable2 Top Chord4 15 60 25 Bottom Chord 5 0 0 .Solar-Ready3 Top ChQrd4 is 0 25 Bottom Chord' 5: 0 0 Roors: loadis are psf Dead Uve Snow, joists, 15 _0 Truss s Top Chord 8 40 0 Bottom Chord 4 0 0 Decks: loads are psf Dead I Live Snow Joistsa 20 _"�O_ _75— Trusses Top Chord is 60 25 Bottom Chord 5 0 0 Notes apply as called out In table above. 2 Roof has direct access and Is Intended to be used by occupants as living space. 3 Dead load includes Spsf for photovoltaic panels. ��cl�or��tci==tural plans. Soil Date JAIlowable Sol[ Bearing 12 SSS Number s1811020 Project Name: i 917 Pine Street Owner FaIrvAnds Development, LLC Project Location. 917 Pine Street Edmonds, WA Design Professional: Novion Group Inc CD 4.n 06 J g E P, c5d I til E 0 Cn @J X F A 771, .'s 01VAL I Ella) ThIs space reserved for governingjurisdiction stamps FEB z 12019 BUILDING ORIGIN DATE: vib/2019 REVISED: S1 Zi'� REQUIRED STUDS HOWN KAM 2x4WAU. 2x6WALL &2-2x(SAWN) 3* (GIB) (2) 20 (2) 2x6 3y, (KA N " — 6x & 3-2x,(SAVVN) Ey 6x (GIB) (3) 2X4 (3) 21k 5%4x (MANF) 8x (SAW W,1 (G. (4) 2X4 (4)1(6 REQD 7� (MANO sm GIRDERTRUSS (3) 20 W116 REQUIRED TRIMMERS IUNG HEM 2X4 WALL 2X6 WALL EADER STUD J HEADER r4x&,L22X(SAWN) 314X (a) 3Y�((MANF) SA 6x & 3-2.x (SAWN) REDD 5%. (GLB) 'y 'x (MAN') TRIMMERS Vx (MANF) NOTE: BEAR BEAMS ON THE FULL WIDTH AND BREADTH OF THE MINIMUM SUPPORTS PER TABLES ABOVE UNLESS NOTED OTHERWISE ON THE PLANS rBHS I BEAM & HEADER SUPPORTS LJN T Imi 00 FC 7SB COLLECTOR SPLICE TO BLOCKING PERSTRU(T NOTES KIP BE T L THRU FLANGE BDEL TOP PLATE, TYR FOR PSI & I% HOLES MUST BE ROUND AND ARE 11MITED TO 2' DIA. UNLESS APPROVED BY THE ENGINEER DO NOT 14AKE PENETRATIONS OR NMES MINIMUM SPACING FCTS� COLLECTOR TO SHEARWALL TN-TE-SHADED AREA OF THE BEAM WITHOUT SHALL BE Zx THE PENETRATIONS IN THIS AREA DO NOT QEQUIR�E AP�PROVAL PRIOR APPROVAL OF THE ENGINEER DIAMETER OF THE FRO M THE ENGINEER L�J��UT�SCB LARGER HOLE T7 Y, DEP-H DEPTH Y3 -EPTT' E-1 0 0 WALL FRMG DEPTH F SHEATHING PER Y, SPAN Y, SPAN Y3 SPAN SPAN PLAN VIEW �SHEATHING PER SCHED FBP� BEAM PENETRATIONS, TYPICAL DETAIL DBL SIDED SW AT ADJOINING WALLS Li N.T.S. BPAA FDSW N.T.S. DSWB Li C.!J- ff] BEAM TO FOUNDATION LiN.T.S. BTFB ' LSTA24 �/ MIN (9) - 10d FASTENERS PER MEMBER DIAPHRAGM U.N.O. I CO=R x OOLUECT70R� BEAM -/ [MEN (9) - lad x I Y2' F*AiTiE4RS PER MEMBER U.N.O. COLLECTOR COLLECTOR t-7 IPLIIE OPTIONALSTRAP LOCATION COLLECTOR SPLICE N.T.S. CSAC A-12 BOUNDARY NAIL ALONG BOUNDARY NAIL ALONG LENGTH OF COLL::OR LENGTH OF::� C ULSCE* 0 OR DIAPHRAGM PER RU7 NOTES INTERMEDIATE FRAMING DIAPHRAGM TO COLLECTOR NT.S. DTCA HEADER OIIR TOP PLATE BEAR BHS STUD PER FRH� FLUSH RIM HEADER, TYP I N.T.S. BOUNDARY NARS PER NOTES 30P MIN SHEATHE NG PER NOTES 2x FLAT BLKwJ DBL ROW OF BOUNDARY WES TRUSS *0 AT BTM FGEB� TRUSS BRACE AT PARALLEL WALL �_i N.T.S. GEBB SH b SOLID NIBS 716 MIN LEDGER (OR ROOF TRUSS) ./ WE PLATE NAILING PER SW SCHED ED BUKG NAILS PER SW SCHED RAFBEROR BASE PLATE NAILING PER SIN SCHED NOTE: THIS CONN ECTION IS FOR SHEAR TRANSFER ONLY, BEARING 0ONNECTION ROOF FRAMING PARALLEL TO WALL ROOF FRAMING PERPENDICULAR TO WALL LOW ROOF TO WALL SHEAR TRANSFER LRW Li N.T.S. LRWB MSTC STRAP HTES NOTE: ALL NAILS SHALL HAVE THE MINIMUM DIMENSIONS SHOWN HERE BE _F XZ l6d LD 0.135" MSTC STRAP -(A) 3" lad HOW1111 L-Y (3)2x STUDS U.N.,O, 6/.' D 0.128" STHD14 64 6A TX. L 2�1, HE. 8d D 0,113" STHQI±(& HPqLM lOdxIW min, HOLDOWNS Li N.T.S. HDNA FNS NAIL SPECIFICATIONS N.T.S. DBL2x STUD EDGE NAILING SIN SHEATHING "Y HOODOWN EMBEDDED S4 HO DO STUDS PER 7*ARqU�NDER HOLIDOWN SCHED SIN SHEATHING EDGE NAILING 2x STIUD 0 HHON ON W 00 LD OL 2x MD ANEHOR HOLDOWN AT CORNER N.T.S. HOCA CANTILEVER TOP CHORD C41MLEVER TOP CHORD AS APPLICABLE Z AS APPLICABLE TRUSS DESIGNED TOP BEAR ON HEADER X TRUSS DESIGNED FUR DIAPHRAGM PER 15" MIN FLUSH HEADER TOP BEAR ON HEADER STRUCIF NOTES (13) 10d TOP PLATE FLUSH HEADER TRUSS TOP PLATE 0TR.G HANGER INSTALLED E UPSIDE-DOWN (2) #CS14 SIDE BY SID �/ FULL NAILING BEAM LE� MIN BEAM (13) lod FIH_C� INVERTED HANGER AT CANTILEVER Li N.T.S. IHCB SSS N—ber: S1811020 Project Name: 917 Pine Street Owner: Fairwinds Development, LLC Project Location: 917 Pine Street Edmonds, WA Design Professional: Novion Group Inc 00 r, W CM Lo") E (U (n V) 0 771 Te nAL This space rese�ed for governing jurisdiction stamps FEB 2 1 2019 BUILDING ORIGIN DATE: 1/10/2019 REVISED: S2 (6) 16d MAILS MAIL' 6.6 —Z 6X6 2xBIO(XTOES,OF6x6, 6P6 2XBLOCKTOE TYP —\ 6X6 REMOVED FOR CLARITY REMOVE' FOR '4i I EE #ILAL- (3) 16d NAILS TRUSS REMOVED FOR OLARITY 2x4BLOCKWI 20 BLOCK To TRUSS (6) 16d NAILS MP & SIM T06XSTOP&BTM (3) 16d MWAILS 2x6 BLOCK .1 (3)16JdNAILS CJ 2x BUD "S (3) IJ NABS 2x BLOCK E.S.. 2X6 BLOCK TRUSIS To . , ST TOP&STM (6)160AILS TO6x6,TOJ`&SrM TRUSS TO 26 BLOCK TOP S TOP & BTM TRUSS TO 2X6 BLOCK TOP&ETM DOUBLE TOP PLATE DOUBLE TOP PLATE DOUBLE TOP PLATE DOUBLE TOP PLATE 6x6 POST AT TRUSS END 6x6 POST BTWN TRUSS SIDE VIEW AT TRUSS SIDE VIEW AT POST (6) 16d NAILS 6X6 2X6 BLOCKTO B.S. OF 6X6 _ 0) 15d NAILS TRUSS TO 2X6 BLOCK 6x6 MIDSPAN 11�Rl POST PEDESTALATTRIIS MIDSPAI M MIDSPAN-SIDE VIEW 6x6 1 K 6X6 (6)16d NAILS (3)16di. (011LO= BLOCKTO6X6 C.1UE TOP PLATE 6X6 ES., TYP DOUBLE TOP PLATE 6x6 AT WALL 6x6 AT WALL -SIDE VIEW BGUARD POST PEDESTAL AT WALL - TRUSSES PARALLEL EE= GUARD POST PEDESTAL N.T.S. ICN —�� P017 ­,\_ 9) . VAPOR BARRIER \— SILL PLATE r A *A35 PER SECTION FUN SILL PLATE AT CORNER FDN SILL PLATE ION CORNER INHERE APPLICABLE L AT WALL SECTION A POST AT FOUNDATION In N.T.S. PBBC 57EEL GUAR POST SPACED 48". MAX T-6' )V TYP (4)MVx6'LAGSCREWS —\r— f±A] STRPLA1E1,x0,,x5' ),,p T 64 GUARD POS I PEDESTAL RED 6x6 WATER -PROOFING III OTHERS SECTION A BEGUALRDIPOST �AMCHMENT DESIGN NOTE MANUFACTURER SHALL PROVIDE A SYSTEM THAT IS DESIGNED TO RESIST THE F01LOMNG LOADS: GUARD RAIL POST - 200 LB CONCENTRATED LOAD IN ANY DIRECTION AT TOP Top RAIL - 200 13 CONCENTRATED LOAD IN ANY DIRECTION AT ANY POINT GUARDRAILINFILL COMPONENTS- 50 PSF APPLIED HORIZONTALLY NORMAL TO THE INFILL *PSPN516 ,vl SHEARWALL BO170M PLATE 8-16d NAILS INTO nR SHEkTHING TOP PLATE E.S. oPSPN58�/ OR PLUMBING I-Bd NAIL INTO i N a BASE PLATE, B.S. 'SP OR 5NG SHEARWALL PLUM FLOOR I *PSPN516 ,,,MIN NOTCH AS REQ IRED DBL TOP PLATE WALL STUD, TYP WALL STUD, TYP ELEVATION VIEW TOP PLATE NOTCH BOTTOM PLATE NOTCH PLAN VIEW PLAN VIEW PENETRATION OF FRAMING - SHEARWALL N.T.S. �_ VUENTOF SHENRINALL SHEARWALL ELEVATION N.T.S. BEAM SIB STRAP ES. SOLID BLOCK wl (8) Hid NAILS X SOLID BLOCK 4x4POSTTYP 40 POST TYP (4X6 @ BEAM SPLICE) 6'-Q'MAX (4X6 @ OEM SPLICE) 6'-O'MAX W1 (4) 10d POST A" A24./(4) 10d POST �2) POWDER ACTUATED FASTENERS (2) POWDER ACTUATED FASTENERS MID CONC (1" EMBED) L INTO ODNC (V EMBED) FFG- FIG 0% SOIL JUNS SOIL NOTE: T OFCSZ2CDUMS1WAND(8J10dNARS MAYBE MIN UEL1OFTHEST9 INTERIOR POST BEAM AND FOOTING N.T.S. PBFB BOUND R NAILING — ZI'MAI --I DIAPHRAGM PER STRUCT NOTES Al 18" TRUSS SHEATHING PER SW EDGE N&U. --r— " __� SHEARWALL _ FOAE� OUTRIGGER AT EAVE L—i N.T.S. OAEE �_ EXIENT OF SHEARWALL 111NIA11 11111 P I EDGE MAILS ROOF DIAPHRAGM BOUNDARY NAILS PER EDGE NAILS ROOF CRAP RAGM Z' BLOCK EDGENAILS EDGE MARS SHEARWALL *H2.5 EA END SHEARWALL GEB EATRUSS T SHEARM i BEARING SHEARWALLS w/ TRUSS PARALLEL FSWR� SHEARWALL ROOF CONNECTIONS L—i N.T.S. SWRC DIAPHRAGM PER NARS PER S rRUCT NOTES SW BONED WALLBASE WALL BASE EDGENAILS PLATEODNN FUR RIM/BUKG PLATECORN (SW ABOVE) SW ABOVE (OR ROOF GABLE) SOLID ELKS OR DIAPHRAGM PER COLLECTOR STRUCT NOTES RIMIBIXG EDGE NAILS PROVIDE *A35 PER EDGE NAIL E PROVIDE BLK'G @ 48"oc SIN SCHED TP (Sw B LOW) BUKG @48" "V JOIST -WALL DOUBLE -SIDED SHEA ALLS, / JOIST -WALL PARALLEL INTERIOR SHEARWALLS, & i PARALLEL EXTERIOR SHEARWALLS E)(T SHEARWALLS @ CANTILEVE] rO FLOOR TO SHEARWALL FSWF� SHEARWALL FLOOR CONNECTIONS N.T.S. SWFA WALL BASE WALL WALL PLATE CONN PER SW SCHED DIAPHRAGM PER MCH PER STRUI SW SCHED RMBU(G ANCH PER 2x SILL U. N.0, SW SCHED PER SW SCHED EDGE NAILS 2x SILL U.N.O. FDN ] FDNI PER SW SCHED SHEARWALLS TO FOUNDATION SHEARWALLS TO FLOOR TO FOUNDATION FSWB� SHEARWALL BASE PLATE & FOUNDATION CONNECTIONS Li N.T.S. SWBA BOUNDARY NAILING DIAPHRAGM PER STRUCT NOTES I Y, x 14 LVL RIM / MIKE DIAPHRAG M �_S PER I PER STRUCT' SW 1-ED1 EDGE NAILS I X X 14 LVL RIMVBLKG 6K, PIP TO FIT wl *SDSY�'x6@8`K TO RIM a:—__ EDGE WAS STEP IN FLOOR N.T.S. SIDAA Z-O' MAX DIAPHRAGM PER STRUCT NOTES 18" TRUSS SHEATHING PER SW AS DIAPHRAGM PER STRUCT NOTES — 61RIPTOFFFNJ *A35 PER 'SDS)�4 x 6 @ 8'iPc, SIN SO TO AIM —1:1 2 x 12 RIM / BUKG rSIR� STEP IN ROOF Li N.T.S. SIDAC (8)16dEVENLYSPACED, 16d @ 16"m T'P ""0' TYP FACE NARS L MIN 2x *01 N . N 71 TPS� DOUBLE TOP PLATE SPLICE �_i N.T.S. TPSA SSS Number: s1811020 Project Name: 917 Pine Street Owner Fairwinds Development, LLC Project Locabo"7 917 Pine Street Edmonds, WA Design Professional: Novion Group Inc fyI ob (n d= z E 0) 0) U) r 'A$ 10 This space reseNed for governing jurisdiction stamps FEB 2 1 2019 BUILDING ORIGIN DATE: 1/10/2019 REVISED: --- S3 3 i-6 BEAM Y4" WEB STIFFENER E.S. @ C40LEVERED TOP PLATE COLUMN CM UNDER BEAM I� MIN TYP X, PLATE COLUMN CTR ON PLATE wo ME FOR )�O BDLT, TYP MEMO` ��4' WEB STIFFENER E.S.@CANTIL ERED FBC_� BEAM TO COLUMN LiN.T.S. BCA e XV . 7V x V III (2) VIVALB, I? 14N EMBED X fGDP DBL NUT "I 4 r ERG PLATE, TYR COLUMN TO FOUNDATION N.T.S. 0? 3',J. 2" 3' SECTION A -A NON -SHRINK GROUP: SHALL MEET ASTM C 1107 2000ps! in 24 hours 6000p,i in 28 days PLACEMENT: Use amixer large enough to penitcordimmus placement before any part of the grout has set. Place the grout quitky. podding the grout lightly will help move material, Avoid vibration which can cause beading and segragallorn. The air, mN & substrate temperatures should all be between 40-F (4.4-C) and 901F M, [��fl GROUTED BASE PLATE �_J N.T.S. GBP BEAM PER PLAN THREADED ROD CONNECTIRD HOUDOWN I? MIN THRU FLANGES W/ (NOT SHOWN) PLATE & WASHER @ BIN SEE PLAN FOR HOLDOWN t," BOLT DIAMETER 10.5" S" 'T'P 3' TYR 3" 3" (6)tSDS"ff' J'TYP — T SCRWVS (6)tSDSJ'x3" Y4" WEB STIFFENER MIN "M POST PER PLAN 'PE P.N S, EWS SCREWS 1Y11 — LOCATED Z' To EITHER SIDE OF ANCHOR HOLE (HALF THE DEPTH OF THE BEAM) T STEEL BEAM ON WOOD BEARING 11 �_J N.T.S. HTB� HOLDOWN ANCHOR TO STEEL BEAM T 1 :1 N.T.S. FLANGE Li HTBGA Ifi-T I WEB d FING, BOTTOM PLATE W 0 CARRIAGE BOLTS 0 '? oc, SIAGGERED 2X TIGHT FIT BLOCKING ) ' BETWEEN OISTS (inches) I d b, I t- 2X NAILER /10dxl%@3V NAIEDTO WEB FILLER W/ 16d 3" VV12x22 1 12.3 1 0.425 4.03 1 0.26 BEAM 3010 PER PLAN \ FSS� STEEL SECTION DIMENSIONS NOR ,pCWgl RO, AT T'' I J N.T.S. .., D ..... �_J ARCHITECTURAL PLANS FACE MOUNTHANGERS 3�4' 0 CARRIAGE BOLTS @ 2? oc BAN WEB FILLER PROVIDE TO FLUSH OUTTER FILLER TO PROVIDE r MIN. OF SOLID "ER PLAN WITH FLADGE EDGES ORG F PER"" FNS_B� NAILER TO STEEL BEAM 3 44 'I\— _T W4 Y I r — F— �, )3 X EIJT L T N.T.S. NSBCA (2) ' smA LE PLA ( Bil Y4; TE J 6) sSDS 4 YDT POST IS R(YrATED 45* UNDER SCREWS E00DBUl FRONTVIEW NON -PERPENDICULAR 601TOM VIEW PLATE VIEW Y /0-Y T 2-26 OR 3x6 NAILER, 11 �T.RE.ADE.D ROD @ 16"m RIP AS REQUIRED WELDED TO COLUMN, TYP WOOD COLUMN TO SKEWED CAP 2x6 P.T. MUD SILL �_J N.T.S. VffSA COLUMN @ CORNER 2-N2 OR 3x6 NAILER FNSC� NAILER TO STEEL COLUMN �_J N.T.S. NSCA BEAM PER PLAN HIM PLATE 3" X' 3' 3'n (6) tr�3" SKCREWS (6) 0 MSDS J')Y tTYP — 1�'MIN LAN SCREW POST PER PLAN SCREWS [STW_@ STEEL BEAM ON WOOD BEARING N.T.S. SSS Number: s1811020 Project Name: 917 Pine Street 0.nar: Fairwinds, Development, LLC Project Location: 917 Pine Street Edmonds, WA Design Professional, Novion Group Inc C:) ­4 06 r, IN, Ln E I= z L"n E 0 0 F A 77 .1 OVAL This space reserved for governing jurisdiction stamps rQr7CEEOVEED FEB 2 1 2019 G�,UILUNG ORIGIN DATE: 1/10/2019 REVISED: --- S4 FOOTING SCHEDULE CRTFIER UNDER CONCENTRATED LOAD U.N.O. FDOTM SIZE REEIMPORCEMENT ID 'ITIDTH ... LE.NG1H UP Dituda� R THICMESS I LONGITUDE ITRANSVERSE F2 Z_y 10. (3) #4 s (3) #,Vs F2.5 2`61 Z-6. 10.1 (3) #4 a (3) #4's NOTE: SEE THE FOUNDATION DETAILS FOR THE BALANCE OF FOUNDATION DETAIL 1 Kmm REINFORCEMENT PER 11101011111 THREADED ROD HOLDOWN ANCH *1 R STEM "'"O""W"O" � F3 3'-0" 10' FDUNDAIION!!L� 'i -------- ­- F4 (4 #5's 1 (4) #S'S 1 _N -(/ I NIP EIGHT REQUIRED TO ACCOMMODATE ANDiORAGE PER LONGITUDE RENF HOLDOWN SCHEDULE 'Mum," TRANSVERSE REINF POST TO FIG I FOOTING DEEPEN FOUN A - TION AS REQD TO _T ACCOMODATED"AR HOLDOWN THICKNESS L — — — EMBEDMENTS INTO WALL L""' ' "' "' I """ - OIVERSEREINF ;1 rDEEEN F D P DUN i ACCOMODATE F, EMBEDMENT., . FMH_E� MINIMUM HOLDOWN EMBEDMENT Li N.T.S. MHE �W'Dri X, WIDTH (LONGITUDE) R RA EV ZANISVERSE) PLINTH 81 MIN U,' 11 2' MUNI rF-I FOOTING, TYPICAL PLYWH ON FrG _F_ 7� W'- FTG P, D) �14'1'@ .1 Ur FTGA ��HOOKINFTG MIN #4 CONT �/!' TOP 12' OF WALL CONC STEM WALL ODNC SLAB CTRD ON FG, U.N.O. OR FINISHED GRADE T-r #4 @ 16'. Rim DOWELS W1 IN 'r-B'KU 14" EXTENSION = 1#4@1�ft 16"MIN VERT TITO WALL &STD HOOK IN FG CLR # ETN_ 4 AT BIN , , F110/w, C.; C] '.X'w I x "I W JW'M'V Q) 14 C�Dffrfr, U.N.O. 11 " FOUNDATION WALL - STEM [!� N T S FWSE I.T. SILL PLATE (2)#4 DINT & A.B. B A B 0 TOP OF WALL 0 ONC STEM WALL CON'W CTRD ON FIG, U.N.O. 4`15" MAX @ E #4 @ 16' 'm r_r I 30" MIN #4 CONT US DOWEILSW MAX 10" M HOME if E)MSION BETWEEN " CONC SLAB r INTOWAI &ST) ULG ONGRADE--_ HOOK IN MIN (2)#4 CO TALL W @ Bill OF M ' ----------- (3) #4 CONT, U.N.O. nN� TENTER VERTS AND DOWELS IN STEM WALL -DEEPEN FOUNDATION AS REQD TO ACCOMODATE FOR HOLDOWN EMBEDMEWS -DEEPEN EXCAVATION TO PROVIDE MINIMUM FOOTING DEPTH [��fl FOUNDATION WALL - STEM LiN.T.S. FWX FrG f Pfl PEDESTAL ON ISOLATED FOOTING �_J N.T.S. PIFA BEARING PLATE SCHEDULE THREADED R(H) 0 0.) WASHER MINIM M EMBEDMENT R�) 314 CUTVVASHER ,, d 718 OUT WASHER IV, I CUTWASHER 11W 1114 CUTWASHER " TWIST HAU1 PINS (2) #4 ANDTIETIGHT HAIR PIN ' Q01"R9 - AGAINSFTHRD ROD ZTWIST&TIETO HAIRPIN 41'KAX CO fle rCURTyP AIIER W D CUBLE NUT/ RAIR PIN FOOTING ELEVATION PLAN VIEW OF VIEW HAIRPIN INSTALL RFA REINFORCED FOUNDATION AT ANCHOR 24" [124'- L HAIR PIN CORNER BAR HAIR PIN OORNER BAR AT CORNER THINESST SW AS EXCAVATION i REQD 2" - H BTM REINF 48' !w /_ MATCH FR3 N.T.S. RFAE rCU;,Tffl THICKNESS, - STEPPED FOOTING GR BEAM Al FSF N.T.S. FOOTINGS �_J MATCH;M= M" coRmERw@ALL OUTER REDIF WALLS r RENF STO .......... MA7�] INTERSECTING ER Z\ ALT'INRTE EA BAR CORNER ALl .' IE"' F'RI REINFORCEMENT AT INTERSECTIONS LiN.T.S. RM w kL D FSRW� SITE RETAINING WALL WITH INTEGRATED BIORETENTION PLANTER WALL SCHEDULE SaWA (4920000)(M)l DIMENSIONS 11' HE A B C D S L (11N) (�.) run (..) (-) (IN) 3 1-8156 8 _JLD__ 8 10 a WNE 4 +8 Bs 8 12 10 8 NONE 5 5-8 56 a 12 10 a 8 6 6_8 56 8 12 10 8 V a B-0 56 8 U 10 12 16 9 9-0 S6 a 14 2 12 M 10 1" Ss Ss 10 14 12 20 REINFORCEMENT M "un' oo� �2 LAP VERT ODAIR 3 " a 16 32 " @ 16 #4@12 04 0 UP MR MR 4 *4 0 ffi 32 �@ 16 " 0 12 #4 @ 10 MR " 0 16 a 16 #4010 K#58 16 32 #4010 � @ 12 *4 @ 10 NR . @ H) 6 *5@6 0 95!16 #4012 94010 NR #508 a #5@8 1) #S@ 12 #4012 M 0 10 MR *5@8 9 .06 Q *50 12 "012 .08 MR #s@g 10 40 #5@ 12 U) #4 @ 6 MR #5@6 --- I OUEA11 COVER REQUIREM (T'10 SOD, Z'TO FORMS MAQUOTHER �MMS) 2DOWELANDVERT MAYBEITHE SAME PECE PROVIDEDTHE SIZE ANDSPACM OFTH DOWELIS USED 3YOUMYENTENDTHE WETOVVITH142"OFTHETOEED�PERTHETDE SPACING USING DOWELS IN BETWEEN RETAINING WALL SCHEDULE SAWF( 45 0 If U21 DIMENSIONS IN E A B IINI (ICN) D (IN) 10 n to REINFORCEMENT H JD0BnM-2J P VERT Ho— ooMr U.) I JNR 24 *40161 .@i�iO (4). 1 1 )4 �@W "@ 1 (4). IC�R�RREQU��(rTOSOli,2"TOMMS�A�OTHER UOQkT1ONS) 2DOWEAN VERT MY BETHE SAME — PROVIDEDTHE SMAND SPAC24GOFTHEDOWS-SUSED 3YOUMAYE�DTHEDJW 10Wr"VN2"OFTMETOEEXE1ERTHe TOESPACING.INGDOWELSMBETWEEN SITE RETAINING WALL N.T.S. SRWC 161 SITE RETAINING WALL WITH INTEGRATED BIORETENTION PLANTER RETAINING VVALI SCHEDULE DIMENSIONS H A J B I C b S L (FT_N "n I) (IN) (IM) (" (" 3 M 16 8 8 10 a NONE 4 +8 20 8 12 10 8 WNE S5_8208121088 66-82881210812 a 8.0 40 8 2 10 12 16 9 9=0 50 8 14 12 �2 IS 10 too 56 10 14 14 12 REINFORCEMENT IT) DOME. .2 UP v MORE 0)" HIM 3 N 0 16 32 " 0 16 #4 0 12 #4010 NR 4 � 0 16 3Z #4 @ 16 #4 @ 12 #4 @ 10 MR a " 0 10 M .010 #4 0 12 #4 0 10 . 6 #S @_L 40 #5 0 16 #4 0 12 #4 @ 10 M 8 -08 40 #5 @ 12 .4012 PI @ 10 NR 9 #5 @ 6 40 #5 0 12 #4 0 12 N @8 MR 10 #S 0 6 40 #5 0 12 .4 @ 10 #40 6 MR I CLEAR COVER REQUIREMENTS (Y TO SOB., T' To FORMS M U_ OTHER WCAMMS) 2 DOWEL AND VERT MY RE T�SAME PEECE PROVEXED THE SEE AM SPACING 0 THEDOWELIS USED 3YOU—ENDTHEDDVIETOW 2" OF TIdE TOE E� PER THE TOE SPACING USING DOWELS IN BETWEEN N.T.S. SRWA L_J N.T.S. SRWA SS Number: 1811020 Project Name: 917 Pine Street Owner: FairvAnds Development, LLC Project Locati- 917 Pine Street Edmonds, WA Design Professional: Novion Group Inc M C"I CD GO ad E Cn g= z E In in 71 STe MAL This space reserved for governing jurisdiction stamps L-31JILEANG ORIGIN DATE: 1/10/2019 REVISED: S5 SYMBOL LEGEND SLEXP tHOLDOWN MODEL HOLDOWN Represe is holdowns which are located at the bottom of the wall where it is called out. Ccinnectbris am no wall_to_mll or wall -to fdn u.n.o. Connections per the HOUDOWN SCHEDULE. — — — CONCRETE WALL AND CONTINUOUS FOOTING See CONCI and R-.'ORCING BAR specifications per DETAIL FWS. F2 SPREAD FOOTING See CONCRETE and REINFORCING BAR specifications per DETAIL FIG. CONCRETE WALLAND CONTINUOUS FOOTING See CONCRETE and REINFORCING BAR specifications per DETAIL FWX. POST Indicates the location of a post within walls below framing. Sizes am indicated on the plan. Grades am indicated In the GENERAL STRUCTURAL NOTES, U.N.O. on the plan. Consult detail BIAS for posts not indicated on the plans. BEAM or HEADER Represents the location of a beam or header. Sizes are indicated on the plan. Grades are Indicated In the GENERAL STRUCTURAL NOTES, U.N.O. on the plan. Headers (HDR) shall be 2-Zx6 at dropped condition u.n... Flush headers (FRIA) shall be 3 Y2 x 5 % LSL at joists u.n.o. Reference detail FRH for Installation of the flush rim header. 3�0 T�R P bar symbol points In the direction of the span. The type, size and max spa7 Ing be= OR RAFTER Re etitive mem members will be indicated in bold type with a symbol which is representative of the layout of the entire level. 74 - — — — — — — — - 6 J.A.W W.W.F. F3 LIZ IL — — — — — — — — — — — — — — — — — — — — — — ------------ L------------ !I ----------------- = F2.5 J I L — — — — — — — — — �J SSS Numbe s1811020 Project Name: 917 Pine Street Owner: Fairvands Development, LLC Project Location: 917 Pine Street Edmonds, WA Design Professional: Novion Group Inc M r"I CD 00 l" r4 E 8 V) Lo', E s'e ONAL This space reserved for governing jurisdiction stamps n0cr-MIJEED FEB 2 1 20S BUILUNG ORIGIN DATE: 1/10/2019 RUM: S6 k�> 0 0-39 SYMBOL LEGEND SLEXP ----------------- DIAPHRAGM BOUNDARY Represents boundaries of the FLOOR DIAPHRAGM and ROOF DIAPHRAGM. — — — — — — — — — — DIAPHRAGM PR03ECTION Represents elements such as roof eaves, facades, and the like. ---------- SHEARWALL Represents walls which are shearwalls and shows the extents of that wall. Connections per the SHEARWALL SCHEDULE. *HOLDOWN MODEL HOLDOWN Represents holdowns which am located at the bottom of the wall where it Is called out Connections are wall-t—all or wall -to fdn u.n.o. Connections per the HOLDOWN SCHEDULE. 0 POST Indicates the location of a post within walls below framing. Sizes are indicated on the plan. Grades are indicated in the GENERAL STRUCTURAL NOTES, U.N.O. on the plan. Consult detail BHS for posts not Indicated on the plans. INTERIOR BEARING WALL Indicates interior walls which support repetitive members. Construct per WALL FRAMING S, BEARING in the GENERAL STRUCTURAL NOTES, U.N.O. on the plan. BEAM or HEADER Represents the location Of a beam or header. Sizes am Indicated on the plan. Grades are indicated in the GENERAL STRUCTURAL NOTES, U.N.O. on the plan. Heaiders, (HDR) shall be 2-2x6 at dropped condition u.n.o. Flwh headers; (FRH) shall be 3 Y2 x 5 Y2 LSL at joists u.n.o. Reference detail FRH for installation of the flush tim header. -JIL U1 HANGER Indicates hanger, standard or concezied flange. Provide fasteners In all holes. Reference the GENERAL STRUCTURAL NOTES for the minimum size hanger. Ifa different model no. Is required, It will be noted on the plan. J-0 T—RUSS 211 KIER Repetitive member symbDi points in the direction of the span. The type, size and max spaM Ing between me T: will be Indicated In bold type with a symbol which Is representative of the layout of the entire Ivel' TENSION -TIE CONNECIrION Indicates a hoIdo%vn or colled strap tension -tie connection. Unless indicated on Plan, use OCS16 with (11) 10d nails per member. T T - T 11 L11 D T IY4xI1%LSI.(1-4) WCS 5W t 4 Sw ISTUDERE — — — — — — — — — — — — — *STHD14 Sw *STHD14 — — *STHD14 SW 7 x It PS. (1-6) A6 - - - A6 (2)2x6HDR _A1 6X6 POST./ *CCQ 0 TOP & *HB 6X6 POS r w/ *HDU8 5X6 POST 11 *PBS @ ETM *PCZ@TOP& *CCOQ @ TOP & *P8 @ OTM *BC @ BUM *S(JR TERRACE LAL��DR�__N, BEDROOM 2 BEDROOM 3 T IXxl4L5SL(l-2l) XV BOLT@ 8V CIS *HDJ8 FSI—Fl i WCS THRU RANGE & DBL BC TOP PLATE 11 SW I I x 14 USL Y, 6)(6POSTw/ P 101 P *CCDQ @ TOP & oBC@BTM GA HS5 AW, tpB@BTM-/ I 1 *HDU8 *HDIJ8 I �IDR IXX 14LSL Y4.14- 15) HDR KDR J J la it: *HDU8 *HDu8 #HGUl I #HHUS HOR HDR ly4Xl4LSL(I-11) 5Y4xI4PS-(l-I6) 3XX14LVL(I-17) fHDU(I-/ 1)'4xl4LSL L *MR-/ D2 - - - - - - - - - - - - - REC ROOM I (3)2x4TRII4MERS *HDL8 - — - — - — - — 4X4 POST w/ 7 PXXwJ5WS CTS NSB BEDROOM 1 6X6 POS7 *HDUB OPB Cl 5;1 OHM n(I.) 'ENTRY ED INK W11(22 (1-8) 1W UP 7�H CQTO;�, H CHU zt O-UMN INN D I LU 1W S SW 3MXII%LSL(I-1�) *SM14 *SMD14 AW6 *STMHDl4 *STHD14 3XX5y4 SL 5Y4x5Y4P5L QPI POS7 W1 WINDCOWMN�/ WINDCOLJMN�J WIND COLUMN w/ sOOQ@TOP& (2 *A3- TOP& (2)#A35@TOP& (2) *A35@ TOP & *PBS 0 UK Ist FLOOR SHEARWALLS & FRAMING ABOVE (2� tA35@BTM (2)*A350ffrM . (2) *A3S @ IITM 1/4" = V-0" DO NOT SCALE - REFER TO AROMECTIRAL SHEErS FOR DIMENSIONS I W UME E f SSS Number: s1811020 Project Name: 917 Pine Street OW r: Fairwinds Development, ILLC Project Location: 917 Pine Street Edmonds, WA Design Professional: Novion Group Inc C) t--q 00 —J C=� . ke) E 0 k—p L! "I R C: V) d= Z U! E 8 Ch N L Ft 771 N L I Id emol, This space reserved for governing jurisdiction stamps_ FED 2 1 2019 BUILDING ORIGIN DATE: 1/10/2019 REVISED: 1--S7 X X f- 69POSTwl_Z/- *CCQ @ TOP & #13CS0 0 ERM 6X6POSTw/ IHC TOPODINNECTION PERT1111MIG& C'. P> K> SYMBOL LEGEND SLEXP ------------------- DIAPHRAGM BOUNDARY Represents boundaries of the FLOOR DIAPHRAGM and ROOF DIAPHRAGM. — — — — — — — — — — IDTAIPMR&GM PROJECTION Represents elements such as roof eaves, facades, and the like. ---------- SHEARWALL Represents walls which am shearwalls and shows the extents of that wall. Connections per the SHEARWALL SCHEDULE. *HOUDOWN MODEL HOLDOWN Represents holdowns which am located at the bottom of the wall where it is called out. Connections am wall-to-wall orwall-tofdn u.n.o. Connections per the HOUDOWN SCHEDULE. Z POST Indicates the location of a post within walls below framing. Sizes am indicated on the plan. Grades are indicated In the GENERAL STRUCTURAL NOTES, U.N.C. on the plan. Consult detail ENS for posts not indicated on the plans. INTERIOR BEARING WALL Indicates interior walls which support repetitive members. Construct per WALL FRAMING & BEARING in the GENERAL STRUCTURAL NOTES, U.N.O. on the plan. BEAMorHEADER Represents the location ofa beam or header. Sizes am indicated on the plan. Gradesam Indicated in the GENERAL STFUCFURAL NOTES, U.N.O. on the plan. Headers, (HDR) shall be 2-2x6 at dropped condition u.n.o. Flush headers (FRH) shall be 3 Y2 x 5 Yz LSL at joists u.n.o. Reference detail FRH for installation of the flush rim header. JIL IJIJ HANGER Indicates hanger, standard or concealed flange. Provide fasteners in all holes. Reference the GENERAL STRUCTURAL NOTES for the minimum size hanger. If a different model no. Is required, it will be noted on the plan. 3_01ST T_RUSS QR 8FII Repetitive member symbol points In the direction of the spar. The type, size and max spacing between rne!bers will be indicated In bold type with a symbol which is representative of the layout of the entire level. TENSION -TIE CONNECTION Indicates a holdown or wiled strap tension -tie connection. Urte�s indicated on Plan, use #CS16 with (11) 10d nails per member. If T JSTOMM 2N CRNUIRE LON If CS CHANGE IN TOP RATE HEDGHT - ------------------------- — T — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — --- 7 *HB SIN *MSTC4Q SW �MSTCAO *MSTC40 SW �LS�40 I wvflo ..Mil) AS AS 112 Z FRH 2 5ylXlly4PSL(2-5) 6X6 POS w/ I I 5Y4x9Y4PSL(2-I6) *BC@TOP& 6X6POSTwJ 08C @ BIN *PU@TM& *11C @ BTI4 X SKL45 DESIGN TRUSS TO RESIST DUG FORCES OF FAH (0.6W) = 14W# (0.7E) 3CO# DINING *HM 6X6 POS7 .1 SIR TOP CDNNECTIO *M5 M PER TRUSS MFG & o8C @ BTM M BEDROOM HANGERS PER TRUSS MFG, TYP P dRY L U� ON POST w/ P"T" TOPODINICUON TORCONIIECUCH n PE"RU" MFG & PER TRUSS MFG & SW LIVING *RC @ BTM 00C 0 011M GIRDER TRUSS (2-15) A6 SW SIN FR Sly *MSTC4) GIRDERTRUSS(2-14) 6 AS AS L— — — — — — — — — — — — — — — — — — — — — — — — — — — 11— _J OPEN TO ENTRY I '4 LIBRARY U010 Q DE1 M 3S -1 AS #M� C52 2 X 12 (2-7) SW SW FAN A6 A6 AS L— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — � CHANGE IN TOP 2nd FLOOR SHEARWALLS & FRAMING ABOVE PLATE HEIGHT 1/4" = 1'4� DO NOT S(ALE - REFER TO ARCHITECIIIIIAL SHEECS FOR DIMENSIONS -A SSS Number: s1811020 Project Name: 917 Pine Street Owner" FairvAnds Developmenli ILILC Project Location: 917.Pine Street Edmonds, WA Design Professional: Novion Group Inc 0 rn CD cb P, E It= Z k� F4 This space reserved for governing jurisdiction stamps FEB 2 1 2019 BUILDING ORIGIN DATE: 1/10/2019 REVISED: S8 SYMBOL LEGEND SLEXP ------------------- DIAPHRAGM BOUNDARY Represents boundaries of the FLOOR DIAPHRAGM and ROOF DIAPHRAGM. — — — — — — — — — — DIAPHRLGM PR03ECTION Represents elements such as roof eeves, facades, and the like. ---------- SHEARWALL Represents walls which a. shea—lls and shows the extents of that wall. Connections per the SHEARWALL SCHEDULE. *HOLDDVVN MODEL HOLDOWt! Represents holdowns which am located at the bottom of the wall where it is called out. Connections am wall-to-wall or mll-to fdn u.n.o. Connections per the HOUDOWN SCHEDULE. POST Indicates the location of a post within walls below framing. Sims are indicated on the plan. Grades am indicated in the GENERAL STRUCTURAL NOTES, U.N.O. on the plan. Consult detail BMS for posts not indicated on the plans. INTERIOR BEARING WALL Indicates interior walls which support repetitive members. Construct per WALL FRAMING & BEARING in the GENERAL STRUCTURAL NOTES, U.N.O. on the plan. BEAM or HEADER Represents the location of a beam or header. Sbes are indicated on the plan. Grades are Indicated In the GENERAL STRUCTURAL NOTES, U.N.O. on the plan. Headers (HDR) shall be 2-2x6 at dropped condition u.n.o. Flush headers (FRH) shall be 3 % x 5 % USL at joists u.n.o. Reference detail FRH for instellation of the flush rim header. JIL U1 HANGER Indicates hanger, standard or concealed flange. Provide fasteners in all holes. Reference the GENERAL STRUCTURAL NOTES for the minimum size hanger.. If a different model no. Is requited, it will be noted on the plan. 3_01 T_FIUSS 2R� sp.,7 g between me b�71!11. Repetitive member symbol points in the direction of the span. The type, sbe and max will be indicated in told type with a symbol which Is representative of the layout of the entire level. TENSION -TIE CONNECTION Indicates a hotdown or wiled strap tansion-tie connection. Unless indicated on Plan, use *CS:16 with (11) 10d nails per member. -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- L SOLAR-READY ROOF DEAD LOAD 20 PSF MAX LIVE WAD 0 PSF MAX SNOW LOAD 25 PSF MAX GPP — — — SOLAR -READY RO F DEAD LOAD 20 PSF LIVE LOAD OPSF MAX SNOW LOAD 25 PSMMAXAX D —L0'A"A'2L0E P'S'FM'AX 'A' LIVE LOAD 60 PSF MAX ROOF DECK 1 SNOW LOAD 25 PSF MAX L— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — i L A ROOF PLAN & FRAMING ABOVE 1/4' = l'-Y' DO NOT SCALE - REFER TO AllafflIECIURAL SHEETS FOR DIMENSIONS SSS Number: sl8d.1020 Project Name: 917,Pine Street Ow er: Fairmilinds Development, ILLC Project Location: 917 Pine Street Edmonds, WA Design Prollessional: Novion Group Inc (14 CD li-41 iRTJ W S E 8 U) E 8 CD r F 77 ST nAl. fall, This space reserved for governing Jurisdiction stamps 7,,1[2_'Q�Z-JVEC:D FED 2 1 2019 IBUILDING ORIGIN DATE: 1/10/2019 REVISED: S9 2--V- 14AX DIAPHRAGM PER STRUCT NOTES 18"TRUSS Zd BOUNDARY NAILING DIAPHRAGM PER STRUCT NOTES 11EITHING PER SW Ph I Y4 X 14 / MG kl�112.S �j DILAVPLHRPEAGM 17A3,SCPER, DIAPHRAGM PER PER IM�l SW E STRUCT NOTES 10 * "— 6 x RIP TO FIT wl j EDGE MAILS *A35 P R *SDSr4 xfi@810� To PI E M x L: L.LS SWSCHED 2 x 12 RIM I BUKG 6x, Pip TORT w/ IuMjBUKG EDGE NAIL oSDS �V X 6 0 8" —'SHEARWALL TO RUI EDGEHMIS rSIR� STEP IN ROOF FSIF� STEP IN FLOOR �—j N.T.S. SIDAC L__j N-T-s- SIDAA D) FEB 2 1 2019 BUILDING SECTION 25, T.27N., R.3E., W.M. N W*E S SCALE : 1*-20' 5' 10' 1. ", 40' .C,rIH Aarv� SECR. 21 Ia.- IIRASS�;' X �q SW CORNER. NM/4. NEI/4 MCI N 2S+ 3'BRASS DISK WV'X" —c— T, I *it , BENCH MARK TOP OF BRASS DISK AT THE INTERSECTION OF 9th AVENUE S. AND PINE STREET. ELEVATION : 100.00 DATUM : ASSUMED T.B.M. TOP OF NORTHERLY BOLT ON FIRE HYDRANT LOCATED FEET NOTH OF THE SOUTHWEST PROPERTY CORNER UTILITY NOTE THE LOCATION OF UNDERGROUND UTILITIES SHOWN HEREON IS APPROXIMATE ONLY. THIS SURVEY DOES NOT PURPORT TO SHOW THE LOCA71ON OF ALL UTILITIES. THE OWNER SHOULD CONTACT THE PURVEYORS OF ALL UTILITIES IN THE AREA TO DETERMINE THE LOCA71ON AND DEPTH OF ALL UTILITIES ON AND ADJACENT TO THE PROPERTY. Ld Ld 0) ,,ROOF PEAK 01 1 270325001 40G THON. E. BELT UNE -I ECIR/W I 'NE EK PROPeriY U CIVY OF �eMONbs "I'l '107 ISP 01-9-61A CITY OF EDMONDS SP #S-24-81 (RECORDING NO. 8,304140,316 AND NO. 840200215) 2 STEW� SO. .,27. S-USCS ONY & SHIRIN DASHTT (REd N, �910214OJ78) PA RCI EL A ou— ES 0' 2 M R_ -to, R/w I (Eli 01'A �PROPERTY UNE 0 FEN 1.1' 1.5'�EST C�-A rI.R.T All NE iLOT A —IR CITY OF E[ #LL-2( -�..\I(REC. NO. -- — — — I — — — — ------ --- --- Ti� EX. C.G. IVE I CAS EX 95 LEGAL DESCRIPTION (ENTIRE PROPERTY) PARCEL A OFCITY OF EDMONDS SHORT PLAT NO. S-9-61A. RECORDED UNDER RECORDING NO. 9102140373, RECORDS OF SNOHOMISH COUNTY. WASHINGTON. BEING A PORTION OF THE NORTHWEST QUARTER OF THE NORTHEAST QUARTER OF SECTION 25, TOWNSHIP 27 NORTH, RANGE .3 EAST. W.M. TOGETHER WITH LOT A. CITY OF EDMONDS LOT LINE ADJUSTMENT NO. LL-2006-100. RECORDED UNDER AUDITOR'S FILE NO. 200609115184. RECORDS OF SNOHOMISH COUNTY, WASHINGTON, BEING A POR'nON OF THE NORTHWEST QUARTER OF THE NORTHEAST QUARTER OF SECTION 25, TOWNSHIP 27 NORTH, RANGE 3 EAST, W.M.; SITUATE IN THE COUNTY OF SNOHOMISH, STATE OF'HA5HINGTON OKERHEAD Im- 100 760911 4 270325 1140GD ALBERT R. COHEN ---- --------- 2702-115200 .88M LOT B r ---- J i i -------------- J, 84) E �. C.B. IN IN l-- I I 1"E I --P-1Z`m'I I'll", I a o all damage to I= R, I right -of my P-"'Ci[y liarlds I or cocu" dtlriMl 0�0 Permitted project, COMPLIES WITH APPLICABLE CITY sp MAXIMUM DRIVC%k',�Y MOPE ALLOWED 14% NOTES 1, A SEPARAIE MGHT-OF-WAY CONSTRUCTION PERMIT IS REQUIRED FOR ALL WORK V47HIN THE CITY RIGHT-OF-WAY. A ROW PERMIT APPLICATICN WITH THE CONTRACTORS SIGNATURE SHALL BE PROVIDED TO THE CITY SHALL BE PROVIDED TO THE CITY PRIOR TO ISSUANCE DF CIVIL CONSTRUC71ON PLANS. A-t'L i2tt.- VAKLrc Tb -gE twv— — SerAIMITE ErD— PMM"rr ISS""" Wt7" THE7 SK.r,-, rwr (PLO Z." Vest - CIVIL SHEET INDEX C1 COVER AND EAST. SITE CONDITIONS C2 CLEARING & SWPPP PLAN C3 GRADING PLAN & GENERAL NOTES C4 ROADWAY & DRAINAGE PLAN C5 ROADWAY & DRAINAGE DETAILS CIS WATER. SEWER AND UTILITY PLAN C7 TMWR& IS TC9 Umex 56-0twAirw FEW41-r C-Z - KtrAL vov=-� APPROVED FOR CONSTRUCTION CITY OF EDMONDS DATE: -yAqllel BY- CrrY ENGOMNG 01IMON W .\ACINITY MAP APPLICANT ENGINEER/SURVEYOR STEVE NIELSO F M AIR NOS DEVELOPMENT, LLC CONTACT. JEFFREY TREIBER LOVELL-SAUERLAND & ASSOCIATES, INC. 13110 N E. 177th PLACE 19217-36TH AVENUE W. SUITE 106 WOODIN _ WASHINGTON 98072 ALLF PHONE 425-396-5757 WO LYNN On. WA. 98036 E-MAIL PH.: C_M 425-775-1591 AIL' JEFFTOLSAENCINEERING.COM FAIRVANDSOFAIRWINDSOEVELOPMENT.COM OWNER STORMWATER SYSTEM ESTATE OF JOAN DEMEROUTIS 921 PINE STREET CITY OF EDMONDS EDMONDS, WASHINGTON 98020 WATER SERVICE PARCEL NUMBER CITY OF EDMONDS 2703250ole a POLICE PROTECTION PROPERTY AREA CITY OF EDMONDS 26,170 SO. Fr. OR 0.601 ACRES PUBLIC SCHOOLS PROPERTY ADDRESS EDMONDS SCHOOL DISTRICT NO. 15 LOT 1 919 PINE STREET LOT 2 915 PINE STREET LOT 3 917 PINE STREET FIRE PROTECTION SNOHOMISH COUNTY FIRE DISTRICT NO. I ZONING SANITARY SEWER SERVICE RS-8 TELECOMMUNICATIONSi CITY OF EDMONDS NATURAL GAS JEREMY FAULT (425) 263-4024 JEREMY.FALLTOM.COM PUGET SOUND ENERGY 111 5208152-47 KEVIN WILLIAMS (425) 691-7573 111 504783749 COMCAST MIKE FONTENOT (425) 263-5482 # PUD-0067-2017 ELECTRICITY P.U.D. NO. 1 OF SNOHOMISH COUNTY MARY McALLISTER (425) 670-3216 # PUD-0067-2017 LEGEND M 4-9 4' CONCREIM -r SEWER MANHOLE UTILITY P.OLE mwemm " 1-3/4' MASS DISK IN (j) "" CATCH BASIN MANHOLE GUY ANCHOR POILE CASINO 1.76' NORIN 0 CATCH BASIN ELECTRICAL BOX 0 YARDMDRAIN TELEPHONE PEDESTAL o STOR DRAIN CLEANOUT 0— CABLE TVBOX 0 MOO SANITARY SEWER CLEANOUT POWER VAULT ss— WATER VALVE LUMINAIRE . FIRE HYDRANT AREA LIGHT — — — — — — — - IRRIGATION CONTROL VALVE GUY ANCHOR WATER SPIGOT H/C HANDICAP RAMP w WATER BLOW -OFF SIGN AS NOTED gas EB- WATER METER x— FENCE AS NOTED SPRINKLER MAILBOX c D4 GAS VALVE BOLLARD GAS MEIER DOZ3ZD ROOKERY —SD— STORM SEWER LINE WETILAND FLAG —SS— SANITARY SEWER LINE TREE AS NOTED (djk) N'U- 401 -W— WATER LINE — E — ELECTRICAL LINE F17/7 ASPHAL71C CONCRETE PAVEMENT — T — TELEPHONE UNE — C — NATURALGAS LINE CEMENT CONCRETE PAVEMENT —011 OVERHEAD U'I1LITY LINES L-07 'a COVER AND EXIST. SITE CONDITIONS FOR FAIRWINDS DEVELOPMENT SP IN NW1/4, NE1/4 SEC. 25, T.27N., R.3E.,W.M. CITY OF EDMONDS SNOHOMISH COUNTY, WASHINGTON W. K- S REVISED PER CITY REVIEW COMMENTS. DAM 4-20-18 07/10/18' Lovell—Sauerland & Associates, Inc. swtT Engineers/Surveyors/Planners/Development Consult ! C 1 LN e-inaff: info@lsaengineering.com *eb: Isaen&eering.Ii0tM-S 19217 30th Avenue T., Sufte 100 Lynnwood, WA 98036 (425)775-1591 DUWN hkl� I .- I J-TT J.Y�. 7-1 ._" , P.r .39 �' I �G' 5677-0-17 .71 NOTES: tLOTES (CONTINUE): SECTION 25, T.27N., R.3E., W.M. 1. WHERE TREES ARE TO BE MAINTAINED. BARRIER FENCING SHALL S. THE STOCKPILE IS TO BE COVERED WITHIN 24 HOURS. BE PLACED AT THE DRIP LINE OF THE TREE IN ORDER TO EROSION AND SEDIMENT CONTROL PROTECT THE ROOT SYSTEM.. 7. INSTALL AND MAINTAIN ALL TESC MEASURES ACCORDING TO APPROVED PLANS. CITY OF EDMONDS STANDARD DETAILS. BEST MANAGEMENT PRAC110ES (BMP'Sl 2, ALL UTILITIES TO BE ABANDONEDIREMOVED. INCLUDING THE CONTRACTOR IS RESPONSIBLE TO MAINTAIN, REVISE AND/OR OVERHEAD POWER FEEDS. SANITARY SIDE SEWERS WILL NEED TO ADJUST ESC MEASURES AS NEEDED THROUGHOUT CONSTRUCTION 1. GRADING AND CONSTRUCTION SHALL BE TIMED AND CONDUCTED IN STAGES TO MINIMIZE SOIL EXPOSURE. BE CAPPED AT THE PROPERTY LINE. AND UNTIL PERMANENT STABILIZATION IS IMPLEMENTED. 2. THE CONTRACTOR SMALL MINIMIZE OR PREVENT THE TRANSPORT OF SEDIMENT ONTO PAVED SURFACE DURING CONSTRUCTION. IF SEDIMENT IS 3. ORANGE BARRIER FENCE AND/OR ORANGE SILT FENCE SHALL BE 8. BUILDING TO BE REMOVED UNDER SEPARATE BUILDING PERMIT. TRANSPORTED ONTO A PAVED SURFACE IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO CLEAN IT AT THE END OF EACH DAY. ADDED ALONG THE EDGES OF THE PROJECT TO CLEARLY 3. SUFFICIENT TESC BMP MATERIALS AND SUPPLIES TO PR07ECT 714E ENTIRE SITE SHALL BE STOCKPXFD ON -SITE PRIOR TO ANY SITE ACTIVITY. DELINEATE CLEARING UMITS DURING CONSTRUCTION. 4. THE CONTRACTOR SHALL MAINTAIN AND REPAIR AS NECESSARY ALL TEMPORARY AND PERMANENT EROSION AND SEDIMENT CONTROL BMPS TO 4. CITY OF EDMONDS DOES NOT ISSUE PERMITS FOR ROCKERIES. ASSURE THEIR CONTINUED PERFORMANCE. ROCKERIES CAN BE CONSTRUCTED BUT MUST BE DONE SO IN COMPLIANCE NTH THE PROHIBITIONS STATED IN THE CODE. NO 5. MAINTENANCE AND REPAIR OF TESC FACILITIES AND STRUCTURES SHALL BE CONDUCTED IMMEDIATELY UPON RECOGNITION OF A PROBLEM OR ROCKERY MAY EXCEED THREE FEET IN SEfafteW-AREA HEIGHT WHEN THE TESC MEASURES BECOME DAMAGED. WITHIN A SETBACK. 6. SEDIMENT DEPOSITS SHALL BE REMOVED FROM ALL TEMPORARY DRAINAGE FACILITIES AND STRUCTURES UPON REACHING A DEPTH OF 6 5. FILTER SOCKS ALL BE ADDED TO ANY CATCH BASINS INCHES, DOWNSTREAM FROM THE CONSTRUCTION SITE. SEE CITY OF EDMONDS STANDARD DETAIL ER-902. 7, SOL STOCKPLES SHALL BE STABILIZED WITHIN 24 HOURS. WHEN ACTIVELY WORKING NTH THE SOIL STOCKPILE, STABILIZATION SHALL OCCUR ATI THE END IOF EACH WORK DAY. IN B. SILTAT10N BARRIERS AND ALL OTHER TESC MEASURES SHALL BE INSPECTED IMMEDIATELY AFTER EACH RAINFALL EVENT GREATER AN 0.1" NMIN OUART4 SECTOR RAINFALL AND AT LEAST DAILY DURING PROLONGED RAINFALL EVENTS. 9. INLETS OF THE PERMANENT DRAINAGE SYSTEM. INCLUDING NEWLY INSTA! I ED INLETS, SHALL BE PROTECTED FROM SEDIMENT INFLUX BY USE OF F " 2"T.-C UPY - ��T RA- SIR FILTER SOCK. MICROPORE BAGS, OR SIMILAR FILTERING MATERIALS AND METHODS. NO -POOF PEAK 11, DURING A STORM EVENT, No CONSTRUCTION ACTIIATY SHALL OCCUR ON SITE EXCEPT FOR WORK ON EROSION CONTROL FACILITIES. ELE.D.. ­�6 1. ALL DISTURBED AREAS TO BE COMPOST AMENDED PER 2014 SWMMWW BMP T.15-3. S27-0113200A 270325 IINOO 270325 114000 2703250 105400 TE-HT �DH M ANV.1 A EHIMN ONSHU ALBERT H. COHEN `HOURS VIRG -Tow"' Fg.,Teo. F6Wf- A% N509-0. rominvot"16A) `F-513clmc. -TO ss IMlllOH..Il '-W('Pf f-t-IEM6"`W 13- FF PRCPEF1 LINE 11 111111-21" 11 218.12' - �.E---- EE PRO CTION LOT 3 I "FIR �PROPIDM LINE IRIIZ P-1-11ON E PROTE TION GA MOSS AREA MIDI �5 Fr WO". ------------------ a, EAVE URE-2 911 S.I. FF Is MST FF \t� A CIL 14 F, 1xv fEA 11 Ld inio M :DD TAILS_Tw`SHEFT----, y TREAMOR ORT �E FF z 2 (TYPI A�o, �l Lij AN AN TREE�PROTE ------ > FOR �U_ < L 2 (9) Z�-2& ACCESS AND E. K EASEMENT TO r---- XOTS 2 A (T) 4 CLE R NO U6111111 �OA CIL U Li :pO K ------------- 5 FH EE, nON No.AR E. IF CTION (2) TON tol 2 IMATER _PlOTIfCTION 1(2) (R 61-LIM CORM I NWI/4. NEI/4 SECTI 25. , "DNA - DISK MIN *X' LEGEND r,y� CLEARING LIMITS _X­ IFLTER FENCE (SIT) DETAIL E1.1) INLET PROTECTION (STD DETAIL E1.3) CONSTRUCTION ENTRANCE TO BE INSTALLED T NEW JOINT ACCESS LOCATION -QUARRY SPA ENTRANCE PER EDMONDS STANDARD DETAIL El., INDICATES TREE TO BE REMOVED FOR SITE DEVELOPM (OTHER TREES MAY BE REMOVED - DETERMINED AT BUILDING PERMIT STAGE) 4 8ENCH MARK TOP OF BRASS DISK AT THE INTERSECTION OF Elth AVENUE S. AND PINE STREET. ELEVATION : 100.00 DATUM : ASSUMED T.B.M. TOP OF NORTHERLY BOLT ON FIRE HYDRANT LOCATED FEET N07H OF THE SOUTHWEST PROPERTY CORNER UTILITY NOTE THE LOCATION OF UNDERGROUND U71UTIES SHOWN HEREON IS APPROXIMATE ONLY. THIS SURVEY DOES NOT PURPORT TO SHOW THE LOCATION OF ALL UTILITIES. THE OWNER SHOULD CONTACT THE PURVEYORS OF ALL UTILITIES IN THE AREA TO DETERMINE THE LOCATION AND DEPTH OF ALL UTILITIES ON AND ADJACENT TO THE PROPERTY. P 0� RUN, - - - - - . . . . . . . . . . V A 2* NOI MIEN FABRIC SEDU IT2 .2'140A KIM FABRIC EOUAL NAME W101U. 2". 2"WOCD/STEEL POSTS-\ I SUR, Bono OF - MMTERRM. V`To Ir NOTES: 1. SHALL MAINUM AMID ENSURE PROPER EROSION CONITOL 1HROUGHOUT PROJECT. CITY INSPECTION REQUIRED ON 2. SILT PENCE TO BE PLACED WWNSUOPE OF ACTIVITY. CONSTIMICTION ALL EROSION QTHL�..­ lA.­UNR I BEFORE WORK CAN BEGIN 'CITY OF EDMONDS � FILTER FABRIC FENCE FILTRATION SYSTEMS REMON DATE JAIRAW 2018 f "R, PU13LIC WORKS STANDARD -, DEPARTMENT DETA91L w. � _ G _ ER-900 -11IR". B III ElHUSH N ll-��IE S 5CALE : 1-20' 0' 5, 10, 20' 30' 40' i kX.C.B. ttlft� " %­;S. rN 'k H. MR-12E THE CONSTRUCTION SWPPP 13 ELEMENTS 1.. ­16.49-12'W \zx. C.B 1 THE 13 ELEMENTS THAT ARE PART OF A CONSTRUCTION SWPPP ARE AS FOLLOWS: 1. MARK CLEARING LIMITS: PRIOR TO CLEARING OR DISTURBING THE LIMITS MUST BE MARKED. THIS ELEMENT IS PART OF MOST NORMAL 114� CONSTRUCT10N PLANS AS ONE OF THE FIRST STEPS. CONSTRUCTION SEQUENCE 2. ESTABLISH CONSTRUC71ON ACCESS; ALL EROSION CONTROL PLANS SHALL INSTALL A STABILIZED CONSTRUCTION ENTRANCE (OR OTHER 1. SCHEDULE A PRE-CONSTRUC71ON MEE71NG NTH CITY METHOD OF PREVENTING SEDIMENT TRANSPORT ONTO THE ROADS). IF A STANDARD GRAVEL CONSTRUCTION ENTRANCE IS PROPOSED. USE GEO-TEXTILE FABRIC UNDER THE ROCK. NOTE. A WHEEL WASH IS REQUIRED FOR PLANS THAT PROPOSE WINTER GRADING. ENGINEERING DIVISION AT 425-771-0220 EXT.1326. TWO DAYS (48 MR.) NOTICE IS REQUIRED. 3. DETAIN FLOWS: BASED ON A DOWNSTREAM ANALYSIS IT MAY BE NECESSARY TO DETAIN RUNOFF FROM A SITE UNDER CONSTRUCTION. IT MAY BE NECESSARY TO CONSTRUCT AND USE A DETENTION POND TO CONTROL FLOWS DURING CONSTRUCTION. 2. REVIEW TEMPORARY EROSION AND SEDIMENT CONTROL NOTES. 4. INSTALL SEDIMENT CONTROLS: IF THERE IS RUNOFF FROM THE CONSTRUCTION SITE, SEDIMENT SHALL BE REMOVED FROM THE WATER. 3. CALL FOR UTILITY LOCATIONS. NOTE THAT THE WATER QUALITY STANDARDS MUST BE MET. 4. INSTALL TESC MEASURES AND MAINTAIN DUST CONTROL WHILE 5. STABILIZE SOILS: ALL EXPOSED AND NON -WORKED SOIL SHALL BE STABILIZED BY USE OF SUP'S. NOTE THERE ARE TIME PERIODS OF PREVENTING DISTURBANCE OF ANY AREAS OF VEGETATION ALLOWED EXPOSURE THAT DEPEND ON THE SEASON. GROUNDCOVER BOTH TEMPORARY AND PERMANENT NEED TO BE PART OF THE OUTSIDE THE CONSTRUCTION ZONE. CONSTRUCTION PLANS. T S. HAVE EROSION CONTROL MEASURES INSPECTED BY CITY OF 6. PROTECT SLOPES: CUT AND FILL SLOPES NEED TO BE PROTECTED FROM EROSIVE FLOWS AND CONCENTRATED FLOWS UNTIL PERMANENT EDMONDS CITY ENGINEERING INSPECTOR. ALL TEMPORARY COVER AND DRAINAGE CONVEYANCE SYSTEMS ARE IN PLACE. SEDIMENTATION AND EROSION CONTROL MEASURES MUST BE IN PLACE AND INSPECTED PRIOR TO ANY CONSTRUCTION OR SITE 7. PROTECT DRAIN INLETS: ALL STORM DRAIN INLETS REQUIRE PROTECT10N FROM SEDIMENT AND SILT LADEN WATER. CLEARING. EROSION AND SEDIMENTATION CONTROL PRACTICES AND/OR DEVICES SHALL BE MAINTAINED UNTIL PERMANENT 8. STABILIZE CHANNELS AND OUTLETS: TEMPORARY AND PERMANENT CONVEYANCE SYSTEMS SHALL BE STABILIZED TO PREVENT EROSION VEGETA77ON IS ESTABLISHED. DURING AND AFTER CONSTRUCTION. CULVERT OUTLETS REQUIRE PROTECTION, 6. DEMOLISH EXISTING STRUCTURES. 9. CONTROL POLLUTANTS: THE PLAN SHALL SHOW HOW ALL POLLUTANTS. INCLUDING WASTE MATERIALS AND DEMOLITION DEBRIS, ALL BE HANDLED. THIS IN CLUDES MAINTENANCE OF CONSTRUCTION EQUIPMENT. FERTILIZERS, APPLICATION OF CHEMICALS. AND WATER 7. ROUGH GRADE SITE AS REQUIRED TO INSTALL DRAINAGE TREATMENT SYSTEMS, FEATURES. 10. CONTROL DE -WATERING: THE WATER FROM DE -WATERING SYSTEMS FOR TRENCHES, VAULTS AND FOUNDATIONS SHALL BE DISCHARGED 8. CLEAR, GRUB & ROUGH GRADE SITE REVEGETATE DISTURBED INTO A CONTROLLED SYSTEM. AREAS NOT SUBJECT TO ADDITIONAL SURFACE DISTURBANCE IMMEDIATELY AFTER ROUGH GRADING. (OTHER EXPOSED AREAS 11. MAINTAIN BMPS-. THE PLAN SHALL PROVIDE FOR INSPECTION AND MAINTENANCE OF THE PLANNED AND INSTALLED CONSTRUCTION B MPS SHALL BE STABIUZED PER EROSION CONTROL NOTES BELOW). AS WELL AS THEIR REMOVAL AT THE END OF THE PROJECT. 9. INSTALL U TILITIES AND OTHER SITE IMPROVEMENTS. INCLUDING 12, MANAGE THE PROJECT.' THE PLAN SHALL OUTLINE HOW THE SITE SHALL BE MANAGED FOR EROSION CONTROL AND IDENTIFY THE FRONTAGE IMPROVEMENTS. MANAGEMENT TEAM, INCLUDING A CERTIFIED EROSION CONTROL SPECIALIST IT NEEDS TO COVER PHASING. TRAINING, PRE -CONSTRUCTION CONFERENCE, COORDINATION NTH UTILITIES AND CONTRACTORS. MONITORING AND REPORTING. IT SHALL PRO14DE 10. STABILIZE AND COMPOST AMEND ALL EXPOSED SOILS PRIOR REVEGUATION OF ENTIRE SITE. ?V?. FOR NOTICE OF PROBLEMS, REVISIONS DU ING CONSTRUCTION AND CONTINGENCY PLANNING. ONE OF THE MOST IMPORTANT ELEMENTS PLA NIN FOR CON71NGENCIES BASED ON THE RISK OF EXPOSURE DURING PHASES OF T14E IN THE MANAGEMENT OF THE PROJECT ISR N THAT PLA IN ISO DEVELOPMENT. IT IS ESSENTIAL NN G ONGOING THROUGHOUT THE LIFE OF THE PROJECT. THE PROJECT CERTIFIED EROSION 11. ESTABLISH LANDSCAPING AND PERMANENT VEGETATION. ALL AND SEDIMENT CONTROL LEAD (CESCL) NAME AND TELEPHONE NUMBER TO BE DETERMINED DURING FINAL ENGINEERING DESIGN. TEMPORARY EROSION CONTROL MEASURES SHALL BE REMOVED UPON FINAL SITE STABILIZATION AND APPROVAL BE CITY 13. PROTECT LOW IMPACT DEVELOPMENT BMPs: PROTECT INFILTRATION FACILITY AREA WITH HIGH VISIBILITY PLASTIC FENCE DURING INSPECTOR. CONSTRUCTION. TREE PROTECTION NOTES: 1. A 4 FT (MINIMUM HEIGHT) HIGH READILY VISIBLE TEMPORARY PR07ECTIVE FENCING, CONSTRUCTED OF CHAIN UNK SHALL BE PLACED AT THE CRITICAL ROOT ZONE OR DESIGNATED LIMIT OF DISTURBANCE OF THE TREE TO BE SAVED. FENCE SHALL COMPLETELY ENCIRCLE TREE(S)_ INSATLL FENCE POSTS USING PIER BLOCK ONLY. AVOID POST OR STAKES I TO MAJOR ROOTS. MODIFICATIONS TO FENONG MATERIAL AND LOCATION MUST RE APPROVED BY THE CITY PLANNING OFFICIAL. 2. TREATMENT OF ROOTS EXPOSED DURING CONSTRUCTION: FOR TOOTS OVER ONE (1) INCH DIAMETER DAMAGED DURING CONSTRUCTION. MAKE A CLEAN STRAIGHT CUT TO REMOVE - DAMAGED PORTION OF ROOT. ALL EXPOSED ROOTS SHALL BE TEMPORARY COVERED WITH CAM P BURLAP TO PREVENT DRYING, AND COVERED NTH SOIL AS SOON AS POSSIBLE, 3. INSTALL HIGHLY VISIBLE SIGNS SPACED NO FURTHER THAN FIFTEEN FEET ALONG THE ENTIRELY OF THE PROTECTIVE TREE FENCE. THE SIGN MUST BE APPROVED BY THE CITY PLANNING OFFICIAL AND SHALL STATE AT A MINIMUM . TREE PROTECTION AREA. ENTRANCE RESTRICTED" AND SHALL INCLUDE THE CODE ENFORCEMENT DIMSIGN AND PROVIDE THE CURRENT PHONE NUMBER (425) 771-0220 TO REPORT VIOLATIONS. 4. No STOCKPILING OF MATERIALS, VEHICULAR TRAFFIC. OR STORAGE OF EQUIPMENT OR MACHINERY SHALL BE ALLOWED WITHIN THE LIMIT OF THE FENCING. FENCING SHALL NOT BE MOVED OR REMOVED UNLESS APPROVED By THE CITY PLANNING OFFICIAL WORK VAIHIN PROTECTION FENCE SHALL BE DONE MANUALLY UNDER THE SUPERVISON Of THE Offl-STIE ARBORIST AND WITH PRIOR APPROVAL BY THE CITY PLANNING OFFICIAL ONNERICOMCTOR IS RESPffiSIELF FOR ALL EXPOSED SURFACES 70 ERMIaN CONTROL AND DRAINAGE BE COVERED W11HIN 2 DAIS APPROVED FOR CONSTRUCTION CITY OF EDMONDS DATE* .y. cl � fN CITY 80NEERING DM90N 01/171/12-clis "Ooo 2 �V MIN RADIUS GUMMY S`AUS 2-e MIN DIA Ir MIN DEPTH IN (DTH MINIMUM LENGTH SHALL BE EXTENDED AS NECESSARY TO ENSURE MATERIAL IS NOT TRACKED OFF SURE AINDIOR ARK VNE PUBLIC NIGHT -OF -WAY. AM DRIVEWAY RAMP AND/OR SM ACCESS ROM IV MOE MIN. SEE TABLE BMW FOR RECUIRED LENGTH. NOTES- 1. SURFACE WATER - ALL. SURFXE WATDI FLOWING OR DIVERTED TOWARD CONSIT MIN ENTUICES SHALL BE PIPM ACROSS DIE ENITAINCE. IF PIPING IS IMPRACIICAL. A MOUNTABLE BERM WITH 5:1 SLOPES WILL BE PERMRIED. 2.MM CE - THE ENTRANCE SHALL BE NTAINED IN A CONDITION WHICH WILL PREVENT TRUCKING OR PLOMNG OF SEDIMENT OFF SHE AWD/OR CIAD MOM RIGHT-OF-WAY. MIS MAY REQUIRE PERIODIC TOP DRESSING WITH ACOITONAL QUARRY SPALLS AS CONDITIONS DEMAND AND REPAIR ANO/OR CUE&NOUT OF ANY MEASURES USED TO TRAP SEDIMENT. ALL SEEM SPILLED . DROPPED, WASHED OR TRACKED OFF SITE AND/011 OHIO POM RIGHT-OF-WAY MUST BE REMOVED `M`EQ"My- J, WHEELS SHALL BE CLEANED TO RUM SEDIMENT PRIOR TO LLUNG THE SITE. WISH WASHING IS USED, IT SHALL BE DON ON AN AREA SIARIUZED WIN QUVIRR� WALLS AND WHICH DUNS INTO AN APPROVED) SEDIMINT TRANNNO GORGE C INSPECTOR AND NEEDED MAINTENANCE SHAUL BE PROVIDED AFTER CARCH FARK PROJECT MIN UENM OF (r -PROVIDE ATE M PHALT WE QUARRY SPALL TRANSNI N WHERE 1/4 ACRE 30 0 E < tACRE SO W CRY INSPECTOR CITY INSPECTION REQUIRED ON 3 ACRE 1. ALL EROSION GO WORK Mno 1 3 ACRE Im BEFORE OTHER NTNOLCA ERISN I REVISION GAT STABILIZED CONSTRUCTION lAWAA. .18 PUBLICINORKS ENTRANCE STANDARD DEPARTMENT DETAIL ER-901 HUGN HOMES '\""\�1DAIC" BASIN NOTES: TH S . DAMON AT nMES DURING CONSTRUCTION PERIOD. 2. ANY SCDIMW IN CATCH MIN INSERT SHALL BE REMOVED WHEN INSERT IS 0 E-THIRO PULL 3. CRY INSPEDINON REQUIRED ON ALL CROSO CONTROL METHODS BEFORE OTHER WORK CAN BEGIN. TEMPORARY REVISION DATE ;,j�----�CITY OF EDMONDS JANUARY 2018 --FUBLIC WORKS SEDIMENT TRAP FOR CATCH BASINS STANDARD DEPARTMENT DETAIL AD, ER-902 APPROVED �.!. ENOUSH L 0-r S CLEARING & SWPPP PLAN FOR FAIRWINDS DEVELOPMENT SP IN NW1/4, NE1/4 SEC. 25, T.27N., R.3E.,W.M. CITY OF EDMONDS SNOHOMISH COUNTY, WASHINGTON REVISED PER CITY REVIEW COMMENTS, DAIED 4-20-18 07/10/18 SECTION 25, T.27N., R.3E., W.M. .ORM 25 - _.- I MONU : - ' lAt4' BRASS SK IN C NO N7 6 I V) i LLJ :3 z Ld a EX. CBMH TOP.99.90 :N N' 81-S'SE , .:1 �_ I . 1. r.E 270-01 400 TH.. �. B­ 270= 011320D ST!�ART .. sCHAM L4 88�92'27- W. 218.Ir 7 --------------- - 1 011" LOT 3 'e 4 --------- j (Typh ---------- \ ---- -------- LOT .......... I .. . ... .. ....... .. .. . .... . .. . .......... .... LL ------ .. . ... ...... .... PR I :"",f UTUTY I, 'RNM ­/4, PAP men 2. Y -SS C"X TH Lx- 11 7C -- - - - �EX.C.13. - - - - - - - - - 1E IP CAS oil memos I F., I; CUT 175.C.Y. FILL , 75 C.Y. EXCESS MATERIAL TO BE EXPORTED TO APPROVED LOCATION OFFSITE. BENCH MARK TOP OF BRASS DISK AT THE INTERSECTION OF 9th AVENUE S. AND PINE STREET. ELEVATION : 100.00 DATUM : ASSUMED T.B.M. TOP OF NORTHERLY BOLT ON FIRE HYDRANT LOCATED FEET NOTH OF THE SOUTHWEST PROPERTY CORNER GENERAL NOTES 1. ALL MATERIALS AND WORK SHOWN ON THESE PLANS SHALL CONFORM TO THE CITY OF EDMON S STANDARD PLANS AND DETAILS, THE FOLLOWING SPECIFICATIONS AND CODES, AND ALL OTHER APPLICABLE LOCAL MUNICIPAL, STATE. AND FEDERAL CODES, RULES AND REGULATIONS. CURRENT INTERNATIONAL BUILDING CODE (IBC) APWA STANDARD SPECIFICATIONS FOR ROAD, BRIDGE AND MUNICIPAL CONSTRUCTION 2BWWSDOT1 -'WASHINGTON TATE DEPARTMENT OF ECOLOGY STORMWATER MANAGEMENT MANUAL FOR THE PUGET ,�0 BASIN (2014 SWMMWW) EDMONDS STORIAWATER CODEj SUX�. IT-30 2. STANDARD PLAN AND TYPE NUMBERS INDICATED ON THESE DRAWINGS REFER TO CITY OF EDMONDS STANDARD DETAILS, UNLESS NOTED OTHERWISE. 3. A COPY OF THESE APPROVED PLANS MUST HE ON THE JOBSITE WHENEVER CONSTRUCTION IS IN PROGRESS. 4. DEVIATIONS FROM THESE PLANS MUST BE APPROVED BY THE ENGINEER OF RECORD AND THE LOCAL GOVERNING AUTHORITY. 5. CONTRACTOR SHALL RECORD ALL APPROVED DEVIATIONS FROM THESE PLANS ON A SET OF "AS-BUILr DRAWINGS AND $HALL SUMMARIZE ALL AS -BUILT CONDITIONS ON ONE SET OF REPRODUCIBLE DRAWINGS FOR SUBMITTAL TO THE OWNER PRIOR TO PROJECT COMPLETION AND ACCEPTANCE, A SET OF AS -BUILT DRAWINGS SHALL BE SUBMITTED TO THE CITY OF EDMONDS PRIOR TO FINAL APPROVAL OF THE BUILDING OCCUPANCY/FINAL PROJECT APPROVAL 6. ELEVATIONS SHOWN ARE IN FEET. SEE SURVEY FOR BENCHMARK INFORMATION. 7. THE LOCATIONS OF EXISTING UTIUTIES AND SITE FEATURES SHOWN HEREON HAVE BEEN FURNISHED BY OTHERS By FIELD MRVFy M OBTAINED FROM AVAILABLE RJECCIRDS =0 �ULD THEREFORE BE CONSIDERED APPROXIMATE ONLY AND NOT NECESSARILY COMPLETE. IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO INDEPENDENTLY VERIFY THE ACCURACY OF ALL UTILITY LOCATIONS SHOWN AND TO FU RTHER DISCOVER AND PROTECT ANY OTHER UTILITIES NOT SHOWN HEREON WHICH MAY BE AFFECTED By THE IMPLEMENTATION OF THIS PLAN. CONTRACTOR SHALL VERIFY LOCATION, DEPTH, SIZE, TYPE AND CONDIT10N OF EXISTING UTILITY LINES AT CONNECTION OR CROSSING POINTS BEFORE TRENCHING FOR NEW UTILITIES . ENGINEER ASSUMES NO RESPONSIBILITY FOR THE COMPLETENESS OR ACCURACY OF THE EXISTING UTILITIES AND SITE FEATURES PRESENTED ON THESE DRAWINGS. ENGINEER SHALL BE NOTIFIED IMMEDIATELY OF CONFLICTS THAT ARISE. 8. CONTRACTOR SHALL LOCATE AND PROTECT ALL UTIU71ES DURING CONSTRUCTION AND SHALL CONTACT THE UNDERGROUND UTILITIES LOCATION SERVICE (1-800-424-5555) AT LEAST 48 HOURS PRIOR TO CONSTRUCTION. 9. CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AT THE PROJECT SITE BEFORE STARTING WORK AND SHALL NOTIFY OWNER'S REPRESENTATIVE OF ANY DISCREPANCIES. 10. PIPE LFNMS WHERE SHOWN ARE APPROXIMATE AND MAY CHANGE DUE TO FIELD CONDITIONS. 11. CONTRACTOR SHALL OBTAIN A COPY OF THE GEOTECHNICAL REPORT (WHERE APPUCABLE) AND SHALL THOROU GHLY FAMIUARIZE HIMSELF WITH THE CONTENTS THEREOF. ALL SITE WORK SHALL BE PERFORMED IN STRICT COMPLIANCE WITH THE RECOMMENDATIONS OF THIS REPORT. 12. STRUCTU AL FILL MATERIAL AND PLACEMENT SHALL CONFORM M THE RECOMMENDA71ONS OF THE PROJECT GEOTECHNICAL REPORT. 13. SUBGRADE SOILS IN ALL AREAS WHERE RAIN GARDENS. INFILTRATION OR PERVIOUS PAVEMENT IS TO BE PLACED SHALL BE DEUNEATED AND PROTECTED AT ALL TIMES FROM COMPACTIVE ACTIVITIES (I.E. HEAVY EQUIPMENT. STOCKPILING). 14. MANHOLES. CATCH BASINS. UTILITIES AND PAVEMENT SHALL BEAR ON MEDIUM DENSE TO VERY DENSE NATIVE SOL OR C MPACTED STRUCTURAL FILL I SOIL IS DISTURBED, SOFT� LOOSE, WET OR IF ORGANIC MATERIAL :S PRESEONT AT SUBGRADE ELEVATION,FREMOVE AND REPLACE WITH COMPACTED STRUCTURAL FILL PER GEOTECHNICAL REPORT. 15. SEE SURVEY AND ARCHITECTURAL DRAWINGS FOR DIMENSIONS AND LOCATIONS OF BUILDINGS. LANDSCAPED AREAS AND OTHER PROPOSED OR EXISTING SITE FEATURES. 16. SEE ARCHITECTURAL DRAWINGS FOR PERIMETER FOUNDATION DRAINS. FOUNDATICN DRAINS SHALL BE INDEPENDENT OF OTHER SITE DRAIN LINES AND SHALL BE TIGHTUNED To THE STORM DRAIN SYSTEM WHERE INDICATED ON THE PLANS. 17. ALL REQUIRED STORMWATER FACILITIES MUST BE CONSTRUCTED AND IN OPERATION PRIOR TO INSTALLATION OF ANY PAVEMENT UNLESS 07HERWISE APPROVED BY THE ENGINEER. 18, ALL ROOF DRAINS, PERIMETER FOUNDATION DRAINS, CATCH BASINS AND OTHER EXTERNAL DRAINS SHALL 13E CONNECTED TO THE STORM DRAINAD SYSTEM, UNLESS NOTED OTHERWISE. 19. ALL FOOTING DRAINS SERVING BUILDINGS, WALLS, ROOKERIES, ETC. SHALL CONNECT TO THE STORMWATER MANAGEMENT SYSTEM. 20. CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS REQUIRED FOR INSTALLATION OF ALL SITE IMPROVEMENTS INDICATED ON THESE DRAWINGS. 21. A SEPARATE IRRIGATION PERMIT MUST BE OBTAINIED FROM THE CITY PUBLIC WORKS DEPARTMENT. PRIOR I. CONSTRUCTION ACCEPTANCE, PROVIDE TO THE CITY WATER QUALITY TECHNICIAN. A COPY OF THE BACKFILOW TEST REPORT. TEXT REPORTS CAN BE FAXED TO 425-744-6057 OR EMAILED TO IMONDSWA,G BACKFLOW TESTING'SHALL BE COMPLETED BY THE OWNER ANNUALLY THEREAFTER. 22. AS A MINIMUM REQUIREMENT, ALL DISTURBED AREAS ON AND OFF SITE SHALL BE RETURNED TO THE EQUIVALENT OF THEIR PRECONSTRUCTION CONDITION IN ACCORDANCE WITH APPROPRIATE REQUIREMENTS AND STANDARDS. 23. ALL DISTURBED SOIL AREAS SHALL BE COMPOST AMENDED AND SEEDED OR STABIUZED BY 01HER ACCEPTABLE METHODS FOR THE PREVENTION OF ON -SITE EROSION, AFTER THE COMPLETION OF CONSTRUCTION. SEE EROSION CONTROL PLANS FOR SPECIFIC GRAD NO AND EROSION CONTROL REQUIREMENTS. 24. THE CONTRACTOR SHALL KEEP OFF -SITE STREETS CLEAN AT ALL TIMES BY SWEEPING. WASHING OF THESE STREETS WILL NOT 13E ALLOWED WITHOUT PRIOR APPROVAL 25. THIS PROJECT IS NOT A BALANCED EARTHWORK PROJECT. BOTH EXPORT AND IMPORT OF SOIL AND ROCK MATERIALS ARE REQUIRED. 26. SLOPE OF FINISHED GRADE SHALL BE CONSTANT BETWEEN FINISHED CONTOURS OR SPOT ELEVATIONS SHOWN. 27. FINISHED GRADE SHALL SLOPE AWAY FROM BUILDING WALLS AT MINIMUM 5% SLOPE FOR A MINIMUM DISTANCE OF 10 FEET. 28. CONTRACTOR SHALL BE RESPONSIBLE FOR AND SHALL INSTALL AND MAINTAIN SHORING AND BRACING AS NECESSARY TO PROTECT WORKERS. EXISTING BUILDINGS, STREETS, WALKWAYS, UTIUTIES AND OTHER EXISTING AND PROPOSED IMPROVEMENTS AND EXCAVATIONS AGAINST LOSS OF GROUND OR C VING EMBANKMENTS. CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR REMOVAL OF SHORING AND BRACING, AS REQUIRED. 29. ONTRACTOR SHALL OBTAIN APPROVAL OM THE CITY AND FOLLOW CITY PROCEDURES FOR ALL WATER C C 7 U S�H DRANT S UT5FS STREET CLOSURES OR OTHER ACCESS RESTRICTIONS. SERVI E IN ERR P TION I R EUMI� CONTRACTOR SHALL No RELOCATE 0 ATE ANY HYDRANTS WITHOUT FIRST OBTAINING WRITTEN APPROVAL FROM THE FIRE MARSHAL, 30. COORDINATE AND ARRANGE FOR ALL UTILITY CONNECTIONS, UTILITY RELOCATIONS AND/OR SERVICE INTERRUP71ONS WTH THE AFFECTED OWNERS AND APPROPRIATE UTILITY COMPANIES. CONNEC71ONS TO EXISTING UTILITIES SHALL BE MADE ONLY WITH ADVANCE WRITTEN APPROVAL OF THE AUTHORITIES GOVERNING SAID UTILITIES. 31. ALL UTILITIES SHALL BE PLACED UNDERGROUND. 32. EXISTING UTILITY LINES IN SERVICE WHICH ARE DAMAGED DUE TO CONSTRUCTION WORK SHALL BE REPAIRED AT CONTRACTORS EXPENSE AND INSPECTED AND ACCEPTED BY CITY OF EDMONDS AND OWNER'S REPRESENTATIVE -NOR TO BACKFILUNG. 33. NEW UITUTY LOCATONS ARE GENERALLY SHOWN BY DIMENSION. WHERE NO DIMENSIONS ARE INDICATED, LOCATIONS MAY BE SCALED FROM DRAWINGS. FIELD ADJUSTMENTS SHALL BE APPROVED BY OWNER'S REPRESENTATIVE AND CITY. 34. FIELD STAKE ALL UTILITY STUBS AT THE PROPERTY LINE 35. TRENCH BACKFILL OF UTILITIES LOCATED WITHIN THE CATY RIGHT-OF-WAY SHALL BE COMPACTED TO 95X COMPACTION TEST REPORTS SHALL BE PROVIDED TO THE CITY PRIOR TO PAVING. 36. WHERE NEW PIPE CLEARS AN EXISTING OR NEW U71UTY BY 6" OR LESS, PLACE POLYETHYLENE PLASTIC FOAM AS A CUSHION BETWEEN THE UTILITIES. 37.SEE MECHANICAL DRAWINGS (MERE APPLICABLE) FOR CON71NUATION OF SITE UTIU71ES WITHIN THE BUILDING. 38. SEE ELECTRICAL DRAWINGS (WHERE APPLICABLE) FOR EXTERIOR ELECTRICAL WORN. 39. SEE LANDSCAPE DRAWINGS (WHERE APPLICABLE) FOR SITE IRRIGAIION SYSTEM. 40. PIPE MATERIAL AND SIGNAGE SUBMITTALS SHALL BE PROVIDED TO THE CITY ENGINEERING DIVISION FOR APPROVAL PRIOR TO INSTALLATION. 41. SETBACKS SHOWN ARE FOR REFERENCE ONLY AND VEST NO RIGHT. U11LITY NOTE THE LOCATION OF UNDERGROUND UTILITIES SHOWN HEREON IS APPROXIMATE ONLY. THIS SURVEY DOES NOT PURPORT TO SHOW THE LOCATION OF ALL UTILITIES. THE OWNER SHOULD CONTACT THE PURVEYORS OF ALL UTILITIES IN THE AREA TO DETERMINE THE LOCATION AND DEPTH OF ALL UTILITIES ON AND ADJACENT TO THE PROPERTY. 1­99.22-6'M C.B. TOP=100.25 ­1­1131oo �NTHCHY & SHRIN DASH� m um m- n (TV.) UR� N W*E SCALE : 1"=20' J. gn, 20' 30, 40' 27032WO 14000 AI.BERT H. COHN 2703250 5 _EYO11 200 LOT 1 Dom w E AND UTIEs S ECN M BX EM IT 1 TS D .3 x, -------------- ILL---- 'MEAS;;" E APPROVED FOR CONSTRUCTION CITY OF EDMONDS DATE-' BY. 6ITY ENGINEERING DIVISION B. D7 7 OVONFAD _-EX. �CBMH �T2 �-a OP 12C2�1143� TOP-12Z59 1NV=I2O.­r N-S 1­8"N IR 1195-VE E IT .11%E.� TH j 'N i-31V BRASS DISK GAMING 1.7W NORTH PER ow w NOTES 1. OPMENT PLAN IS BASED UPON PRELIMINARY HOUSE PLANS AND MA R H MES TO BE CONSTRUCTED 2. THE GRADING SHOW MINARY HOUSE PLANS AND SUBJECT M CHANGE AT THE MENT OF FINA M P NS. DITIONAL TREES MAY BE REMO%ED - DETERMINED T BUI STAGE. GRADING PLAN & GENERAL NOTE�S FOR FAIRWINDS DEVELOPMENT SP IN NW1/4, NE1/4 SEC. 25, T.27N., R.3E.,W.M.: CITY OF EDMONDS SNOHOMISH COUNTY, WASHINGTON WjL REVISED PER CITY REVIEW COMMENTS. DATED 4-20-18 07/10/iS Lovell-Sauerland & Associates, Inc. gm�ET ErLgineers/Surveyors/Planners/Development Consultants i 35420 e-mad: Wo@baeugineering.com web: Isaengineering.com C3 19217 36tt Avenue IT., Suite 100 - Lynnwood, TrA 9aO36 (425)775-1591 DRAWN CHECKOD DATE F.B. FM END. 0-1/ J.T.T. I jy 1 3-16-18 1 $39. P,57 I SCALlF-20' 5677-0-17 o1,7 NORTH 0. R I -GN 'S. EK ��A C NORM MGM..., _X_ IN 1-3/4- BRASS ISK IN CA.H. SIZE III t4IWlMM CLenW VVITHI V;Ey(AH`CLL- Is LLI z LILI > -C INN-97.70-8' RV�W.81).NE (NEW) W- I 0011 1 - AIR NO OPA pip 01 IF , '0 010,01,I]IIII 11 - 2­50GI0 400 THOMAS E� ­T FACAIER - X) GE REUDCATED MIND 11HE SIDEVAI.K. CODIRGAINATE IMW fNJD 10 DETERMINE FOUE LOCATM DR TOP TOP 8 Dry 'N"OPENT, R/. T 0� ilf" ink W1 14, f>1_K) 201-70055 2703250DI1320I) MWARY J. SCRAM ol, I.AU* DFROUK. "m Troll OF R - IDD.80 10LE10 N 88-�227' 21 _18WA 2' RGI UNE COVER LOT 3 NIEW SINGLE FAMILY I RE �IDEN I'lr, GARAGE R RL .0 RA D�MR=. 00.50 DRAN� T AND as �,L ER J. imylozes I I m classING N �_PVC (CORRECT TO RCCIF GRAIN) sa ------------- �103.7* ------- ----- IDA LOT 2 TOF OF ROCK -, 1­83 ECmGM � ROCK - IGG-W ��W SINGLE FAMI a- �Y INV. IOZ. I RESIDENCE I No .1 INFLFWA IMFOCK 3 . on, R INv - I w w 1111 P xax, c -R- P 14&1� s"i IY� V, AL/ Lff PWII-7 / / /\/ 1Z V Z A 7 SW CORN R, N./4. NO/4 SE. N �1 Y GRASS DISK lGrrH 'X' MP=100.41 EX. C.B :'N'-_." .­" E X. C.B. 1111.100.1�14*E Is COE GIs lf4AEFIQ NOTES: I ALL I?MI5-MW.BE RESTRIPED. AS REQUIRED. PRI Ek C.B C COM�f 2. EX . STOP SIGN/S EET NA AY NEED TO BE REMOVED FOR THIFRECONSTRUCTIOIR AMPS. OMPLETION OF ADA RAMPS, RE -INS P SIGN AND NEW POST SAME LOCATION. TTHE STRE NAME SIGN "PINE Sr AND NEW POS . LOT 3 PLA Zbi-) DOSS. PROJECT SITE CATEGORY. CATEGORY 2 DISCHARGE LOCATION: . PUGET SOUND THROUGH THE CITYS MS4 LEGAL DESCRIPTION (ENTIRE PROPERTY) PARCEL A OF CITY OF EDMONDS SHORT PLAT NO. S-9-61A. RECORDED UNDER RECORDING NO. 9102M373, RECORDS OF SNOHOMISH COUNTY, WASHINGTON, BEING A PORTION OF THE NORTHWEST QUARTER OF THE NORTHEAST QUARTER OF SECTION 25, TOWNSHIP 27 NORTH, RANGE 3 EAST, W.M. TOGETHER WITH LOT A. CITY OF EDMONDS LOT LINE ADJUSTMENT NO. LL-2006-100. MISH Cou SECTION 25, T.27N., R.3E., W.M. N I ;u ;u > > Do x W*E S 000. SCALE : V-20' -.DETECTABLE WARNING SURFACE T V 10 20' 30 40' 27032SK.15EK0 270326 0114000 1 . . ANMON, I SHIRIN 0AENn AOEFT H. COHEN 5.00,­ Limits ofrequired construction under this permit 6" CURB AS EQUI RED stub/cap 5" "000 temporary RENCE D ABLE WA S FOMIM& D%AikV MAq biscmA9.6E To OR-ywfiu. R"VEUfiM/%= WAU.FQTT.) b_ MA �M CM 03A A5 LWl5k AS FOC-111IJ& PItAlr0s 0An SE ROCK Y TO BE 1. STA&D WITH LOT I I PLAMV, AT AA) 51.eVe?0)V or- It, o 0 SLIMING PERMIT ,.a, OIL mlwls�, �PROFTI UNE (W' ASOVE 76P Or wt.% J") 0 --------------------- -R04f WHE Yw.) MCI: I,. To Al� IF Ri>TItJrA OPLAIMS CAMP& l5e 1PLAC-SP AMOVE 1.51 WEST AJJ AVF 00 NEW ±16.2' RAMP EX. 5' WALK C 'bum, DISCRAP-6,1E POINT ,e�r feai rect ITto C at WILL- NF-51> 70 %J�- IA?6-TA$-LSJ>. d flCit-_ dri to be rem a unvowIly is Or J REP -ACE EYJS71NG CURB I I . i , I MAXIMUM DRIVEWAY SLOPE LU 1' 1 ­ L NEW SINGLE FAMILY 2703M 152M ALLOWED 14% RESIDENCE JEFFREY IRESEFt NO aASEMENrF ACCEPTABLE TIGHTLINE MATERIAL FOR LOT S SDR 35 0' ACCESS AN"TILITIES ENT TO BENERT SON 40 flY SEMs! ESAIT F ...... Z ANU a N-12 F810 HANCOR CURB RAMAP DEITAI N CACE 0 SCALE Applicant shall repair/replace all damage to Lififfies or frontage improvements in City rA"f`dl`J`6TtSP Vk)D'I;IL -TI415 right-of-way per City standards that is caused ­SEG 100' US C UTILITY or occurs during the permitted project NOTES, No E C C.B. IGCK SERIE's GO ENT NGV- s-,'" 802 SH.G. _ HIGH 0N.GFE. _.__S`GNRaX,IRED =,=� -- - - - - - - - - - - - SEEN FFNA, GHE -_ AN AAR_ UKM` NEXINT 1. aGrYA1 OF SIGN SIDGESOREMW SNAX ME 3W. 4`X e CG.CFETE JIAENT ,_/4� .1.S, DISK IN CAU ZIV F_,- 0" 2 2 -ST IF 9 A. \EX. C B. \EX. 10' SIGHT DISTANCE CLEAR EX. CBMH 1­14 INV-120.14-8" E No OBSTRUCTIONS GREATER 701`122 N . -S . iNvZ1114 30" IN HEIGHT A plavate drainage easement is required across Lot 2 & 3 for the benefit of all driveway users and DO 3; a note to tWs effect shall be show on the final plat Map. MDRRMYb��NAGEMENT FACIUMES�: ALL FACILITIES FOR LOTS 2 & THE CONSTRUCTION OF THE SINGLE FA S. CURVE DATA (-JOINT ACCESS- q) CURVE NUMBER CURVE INFORMATION STATION DESCRIPTION ELEVATION FG A 38*48:5 . 9 pCi 111.66 R 74 CO I !Rfl,' L T 0. 7 PI 110.98 A 32� 2410 0+90.67 PC2 ilOM98 R !a UO _.T 9.31- 1+08,55 PT2 110.70 LOT 1 PROJECT SITE CATEGORY. CATEGORY 2 RECORDED UNDER AUDITORS FILE NO. 200609115184, RECORDS OF SNONO WASHINGTON. BEING A PORTION OF THE NORTHWEST QUARTER OF THE NORTHEAST DISCHARGE LOCATION: PUGET SOUND 1HROUGH THE C11YS MS4 QU- OF SECTION 25 TOWNSHIP 27 NORTH RANGE 3 EASTWM; SITUATE IN THE COUNTY OF SNOHOMISH, STATE OF WASHINGTON. INFILTRATION TRENCH #1 TO BE CONSTRUCTED NTH LOT I BUILDING PERMIT, DRYWELL #3A TO BE CONSTRUCTED WITH LOT 3 BUILDING PERMIT DRYWELL #39 TO BE CONSTRUCTED NTH SHORT PLAT IMPROVEMENTS BENCH MARK LOT 2 TOP OF BRASS DISK AT THE INTERSECTION OF 9th AVENUE S. AND PINE PROJECT STE CATEGORY: CATEGORY 2 STREET. DISCHARGE LOCATION: PUGET SOUND THROUGH THE CITYS MS4 VATION : 100.00 DATUM : ASSUMED T.B.M. TOP OF NORTHERLY BOLT ON FIRE HYDRANT LOCATED FEET N07H OF THE SOUTHWEST PROPERTY CORNER U11LITY NOTE THE LOCA71ON OF UNDERGROUND U71UTIES SHOWN HEREON IS APPROXIMATE ONLY. THIS SURVEY DOES NOT PURPORT TO SHOW THE LOCATION OF ALL UTILITIES. THE OWNER SHOULD CONTACT THE PURVEYORS OF ALL UTILITIES IN THE AREA TO DETERMINE THE LOCATION AND DEPTH OF ALL UTILITIES ON AND ADJACENT TO THE PROPERTY. IMPERACIUS AREA CHART TYPE OF AREA SQUARE FOOTAGE STORMWATER FACILITY LAWN AMC LANDSCAPE DISTURBED AREA BMP T5.13 ROOF NEW DRYWUW3A DRIVEWAY NEW 1.080 DRYWELL#38 WALKWAY NEW 27 DRYWELLOS r_­NT DRIVE Y NEW 694 DRYWELWB 1 = RETROFIT - I NOT APPLICABLE IMPERVIOUS AREA CHART TYPE OF AREA SQUARE FOOTAGE STORMWATER FACILITY LAWN AND LANDSCAPE DISTURBED AREA - BMP T5.13 ROOF (NORTH HALF) NEW 1.339 INFILTRATION TRENCH #2 ROOF (REMAINDER) NEW 1.126 -rN-FILTRATIONTRENCH #2A DRIVEWAY NEW 952 INFILTRATION TRENCH #2A WALKWAY NEW 15 INFILTRATION TRENCH #2A 25% RETROFIT NOT APPUCA13LE NOTES, ,-- - - __1 __ - - ENGN SHEEN- .00­ - sACK-G. . ..- AND .. - - GE - D SUMS D D - AS PER THE W. GHWAY Ms AND MAFNNs (SRSID s. AM. Gans. a- GE W. DIF G_ CASE unnERS. �_.VTMGG_SKNS MG-- - - GN - IGFN NAME 01F.W. =IN 7-ND. � SIGNS NO - GN - INKIRE SNA� HANE - NAME OF - IN 5- -HC INOWNW, TYPE AS (�. AVE, DR. PL. WAY. CIF4 ac) AND CoCKAFRO Gej C-AND.O. 7.- GVERNEND CNMF- S- NASTARMS) HANS THE OF— IN 12' UTERNG wGMxx I REGOGIFED FOR STREET NAME SIGN AND CITY _OFEDMONDS FIRE -AID ADDRESS AND PUBLIC WORKS POST MOUNTING DETAIL DEPARTMENT S�AN XRD -1. TR-57 FED 2 1 BUILC)ING L -T l!) a ROADWAY AND DRAIMAGE PLAN 0+00 FOR JOINT ACCESS PROFILE FAII?WINDS DEVELOPMENT SP SCALE: HOR. 1" 20' VERT 1, 5' IN NW1/4, NE1./4.SEC. 25, T.27N.,,R.3E.AM. CITY OF EDMONDS APPROVED FOR CONSTRUC'nON CITY OF EDMONDS SNOHOMISH,. COUNTY, WASHINGTON 1. _It"�T PLAN IS BTlSE.&UCP.0,N P�ILEU.MINARY HOUS PLANS AW'%rA-Y NOT VIX THE S� 'ST G ON I REVISED PER CITY REVIEW COMMENTS, DATED 4-20-18 .07/10/18 DA7L- TO 0 GEMENT 2. ALL IMPERVIOUS SURFACES DIRECTED, STORM -AL -AR IJANA -Sauerland & Associates, Inc. smT Lovell CEPTUA SYSTEMS. ALL STORMWAIER MANA ARE C EPTUA NO TO BE FINALIZED AT THE BUILDING PERMIT. Engineers/surveyors/Planners/l)evelopment Consultants 3. THE STORMWATER CODES CT AT THE S�IME OF A ON FOR THE SUBJECT CITY ENGINEERING DIMSKIN 3542X -e-mail: info@lsaen&eering.com web: Isaengineering-com C4 SUBDIVISION SHALL AS LONG AS C N TRUcTiON OF TH ED SUBDIVISION IMPROVIEMEN NS PRIOR TO JANUAR 1, 2022. IF CONSTRUCTION OT BEGIN 19217 36th Avenue W., Sulite 106 - Lynnwood, WA 98036 (425)775-1591 PRIOR S DATE, THE STORMWATER SYSTEM FOR THE SUBDIVISION SH DRAWN I MIM I DATE'. FU* ED TO COMPLY VATH CODES IN EFFECT AT THAT TIME. J.T.T. J.Y 7- 539. P.57 1.-20' 5677-0-17 o,7 FU IMPERMOUS AREA CHART TYPE OF AREA SOUARE FOOTAGE STORMWATER FACILITY LAWN AND LANDSCAPE DISTURBED AREA BMP T5.13 ROOF NEW 3.235 INFILTRA71ON TRENCH #1 DRIVEWAY NEW 647 INFILTRATION TRENCH #i' WALKWAY NEW DRIVEWAY . 32 INFILTRATION TRENCH #1 25% RETROFIT NOT APPLICABLE M.H. Go PINE S I5­W R /0 28-N rREET @L F_1s a' '120 S. -t-EYS, GFO.ND 67- c c 2 NG" POINT HIGH POINT _PM STA­0+2% 114M G+25.2 - 110 P. EIEV - 1% K - 2.21 5 POINT 1141,61 LC PONT STA - I�n P.- DATUM ELEV 100.00 SECTION 25, T.27N., R.3E., W.M. 20' SpEc 3) (SEE NOTE 4 NOTES, 1. 6' COHCR EXTRUDED CUM ON 18' ASPHALT TPICKERED ME REQUIRED (REFER TO CITY STAHOAM CURB DETAILS). 2. REFEDI TO EDMONDS COMMUNITY DEVELOPMENT CODE TABLE OF STREET STANDARDS FOR EASEMENT AND PROEMEM WDOIS. 3. FIRE DEPARTMENT MAY REQUIRE ACCESS TO BE IMDER IF IT IS DETERMINED TIRE FIGHTING OR RESCUE OPERATIONS ARE HAMPERED. 4. CSBC DEPTH S ALL BE A MINIMUM 6' OR MATCH EXISTING MICHEVEIt IS WEATERL MIN MATCHING EXISTING CSBC OEPTH GREATER THEN 6. THEN CSBC SHALL BE INSIA.I.Ell IN MULTIPLE EQUAL MCKNESS LIFTS NOT EXCEEDING fi*. PRIVATE STREET REVISION DATE FEBRUARY Iola L7-, CITY OF EDMONDS PUBLIC WORKS (1 -4 LOTS) STANDARD DEPARTMENT DETAIL I. iss APPROVED By. R. ENGLISH TR-510 NOTE: IF A THICK ED EDGE IS ADDED TO EXISTING PAVEMENT OR APPLIED AFTER NEIN PAVEMENT IS PLACED. THE ASPHALT SURFACE SHALL BE THOROUGHLY TACKED. REVISION DATE CITY OF EDMONDS ASPHALT THICKENED EDGE JANUARY 2018 PUBLIC WORKS STANDARD DEPARTMENT DETAIL �o APPROVED W. P ENGLISH TR-523 4 F111 PI AN VIEW I (NOT TO SCALE) NIT TO "'N") FULL Fu DE-PTH I/ CURSIGLITTER JOINT .2' EXPANSION SEE COE BID 121 7 jr R-/ -2* IN 5/8- MINUS me N NA ATIVE B ING MIL N. IT (NOT To 1. CITY INSPECTION REQUIRED ON FORM /WORKPRiOR POUR. 2. CONCRETE SHALL BE CLASS 3000. 3. FINISH SHAUL BE UGHT BROOM. 4. SIDMALK THICKNESS SHALI_ BE 4�. 5. SIDEWALK THICKNESS AT DRIVEIRAYS SHALL E S" THICK. - ARA 0. CURB ANO GURMER SHALL 6E POURED S Y MOM SIDEWALK. IT AU �: 7. LOS FOR JUNCTION BOXES AND UTIL LTS SHALL BE NON-SKID AS SPECIFIED BY EINGIN OT M B. SEE COE BID OTL YR-550 MR PO LE ROOT HARRIER INSTALLAVON. 9. SUBGRADE SHALL BE COMPACTED 95. MAXIMU. EH­ CONCR NUARY 201a ETE SIDEWALK STANDARD DETAIL APPROVIZO 81 R. ENGLISH TR-531 *oETpr1&s ntor fttc IW4" T"I'l A-215 rb ge MMM"VO Tw Sftyrr "-F, PW2.3-7 ubms. 2-' /2' R-1-1/2 4fr J PLACE SCORE WKS EVERY 10' SLOPE 1 :12 1/2- MINJ IRIVERAY "11 OR CURB ItAMP SLOPE C NSTRUCT OUT or] HIM PAWMENT CONCRETE CUR SHALL BE NO LESS THAN 3" IN HEIGHT EXTEND PAWMENT 1.3' FROM THE FACE OF CURB IF NECESSARY TO SUPPORT EXTRUDED CURB 'PLACE S' COMPACTED 5/a" csre NOTES, MOW WA, EXTEN=m 1. NOT TO BE USED IN RIGHT-OF-WAY EXCEPT TO REPAIR EXISTING EXTRUDED CURB. AS APPROVED 13Y CITY ENGINEER. 2. EPDXY IS THE ONLY ATTACHMENT METHOD TO BE USED BETWEEN HMA AND EXTRUDED CURB. 3. CONCRETE SHALL BE MR-ENTFAINED CLASS 5000 PER WSOOT STANDARD SPECIFICATIONS. �,",'CITY OF EDMOND§ CONCRETE EXTRUDED CURB REMSION DATE JANUARY 2OtB DEPART ENT M STANDARD DE TAIL esf. 4"1 APPROVED BY. R. ENGLISH TR-522 (D 4 SION EXPANSION NT JG,W 40 SEE DRIVENAY CURB TRANSMONAL DETAIL BELOW COWRETE CURB AND OWNS 6 COE SM DjL SEE FUL� DEPTH M-520 EX'STRG PA EXPANSION MAX IS 2, MN JOINT SL_ SAWC 7 MAX a, CURB 7 2 AND GUTTER -OR NOTES, (D CURB AND PRIOR TO V&�TEDN SHALL BE POURED SEPARXPEUy THE SI ALK. CITY INSPECTION REQUIRED ON MRM WORK R. DR�Ay APRON INCLUDING "NO RAMPS SHALL A MINIMUM OF 6 ICK AND SHAU. RE PLACED ON 2- OF 5/8- mo COMPACTED TO 95X MAXIMUM DENSITY.. SUBGRADE SHALL BE COMPACTED To as% um omsrry. 2' ASPHALT SAWCUT MAY BE REQUIRED IN CUM/GUTTER INSTALLATION. R TO COE STO DTL M-520. (D CONCRETE SKALL BE CLASS 30M. (D CURB TRANSITION SHOULD MAN N PE NO MTER THAN SAX IF THE SLOP QUIREMEVT CANNOT BE ACHIEVED, MAXIMUM CURB THE ON LENGTH SHALL BE 15-FEEr. MAINTAIN 1/2. UP AT GUTTEIR. IF DRIVENAY YOUTH EXCEEDS . NSTX1 A FULL DEPTH EXPANSION JOINT AT CENTER OF 0 @IMSYA� MINIMUM 5-Ft TOM PANEL BEPAIDEN DRIVERAYS AND MEN CONNECTING TO Exii 0 SIDEWALK. FINISH SHAU_ BE U� U. DRIVEWAY APP REVISION DATE TY OF EDMONDS ROACH JANUAWAY 2Ot8 TYPE I PUBLIC WORKS DEPARTMENT STANDARD DETAIL APPROVED BY. R. DMIUSH TR-541 APPROVED FOR CONSTRUCTION CITY OF EDMONDS DATE- Z1_q /1� BY. CITY ENC4NEEPANG DIVISION 2* MIN SAVICUTT 5-1 SEE NOTE 10 R=1/2- AAR MATCH ""EVER IS SEE NOTE 12 MINUS CSTC 19' STANDARD SEE N 11 Malec. (NOT TO SCALLI NOTES, I . C17Y INSPECTION REQUIRED ON WORK PRIOR Up 2. FORMS $HALL BE TRUE TO D GRACE AND SECUR STAKED. 3. EXPANSION JOINTS SMALL ED ADJACENT TO ANY SIM 4. EXPANSION JOINTS 5 , BE EVERY 10 FEET. 5. EXPANSION JOINTS S HAVE 1/2" TO 5/8* WIDE PREMOLDED Jo 6. CONCRERE SHALL 0 CLASS 3DO . 7. FINISH SHALL BE aff BRom 11 CURB SHALL a SPRAYED WITH CLEAR CURING COMPOUND OR SHALL BE COVERED KEPT MOIST MR 72 HOURS. REMOVAL EMENT OF CONCRETE CURB SHALL HE FROM EXPANSION TO EXPANSIO DIRE CITY ENGINEER. INT. UNLESS OTHERWISE 10. A 2-FT [MUM ASPHALT SAWCUr MAY BE REQUIRED AS DETERMINED BY CITY ENGINEER. 11. CU SK4LL BE IS' OR AS DIRECTED By CITY ENGINEER. 12. ALL CAL EDGES SHIALL BE TACKED. CONCRETE CURB R-XIMTE 91TY EDMONDS is _0F PUBLIC WORKS AND GUTTER STANDARD DEPARTMENT DETAIL TR-520 APPROVED BY. R. ENGLISH 6" REMOVABI. 1" VEK TO INFILTRA'nON TRENCH FACTORY TEE FINE MESH SCREEN -- TYPE 1 L C8 QBs #1, #5 #7, 49 & #10 SEPARAJOR TEE DETAII NOT TO SCALE THE TEE SECTION Y&L. BE USED TO RETAIN A UMITED VOLUME OF POLLUTANT THAT FLOATS ON WAX, SUCH AS OIL OR ANTIFREEZE. THE IL CONTROL DEVICE IS P, SSIVE AND MUST BE CLEANED -OUT Sp LL FOR THE SPILLED POLLUTANT TO ACTUALLY BE REMOVED. t- 0-r ROADWAY & DRAINAGE DETAILS FOR FAIRWINDS DEVELOPMENT SP IN NW1/4, NE1/4 SEC. 25, T.27N., R.3E.,W.M. CITY OF EDMONDS SNOHOMISH COUNTY, WASHINGTON REVISED PER CITY REVIEW COMMENTS. DATED 4-20-18 07/10/18 o1/rI/%ot6 SECTION 25, T.27N., R.3E., W.M. DF - FOR FUTUM SVRER STU SHALL BE LOCATED 1W INSIDE PROPERTY UNE A STAKED. PLACE 27.4' TRADER AT END OF SIM SEVER STUB AND OUT TO LENGM TO ENSURE 3 FEET 1- - TOP 1. ­NER WN� AN 3 INCH ­N LETTEIM 5710401. WE NUMBER OF N FEET FROM GROUND ELfWArON TO THE MNOt STUB RESIDENCE INVERT. 8 �M "RE To M DOUBLE WRMPPEG AROUND WE AND 2 4 STAKE AT 27W250 10-0 2­­ 2" ­­ 11- OR ABOVE ­HEO GRACE STEHWHT M. SCRAM ALBERT H. 00� W-S C BUT DA WIN W S, BEND AND CAP N CLEAROUT, (MAX) 21 LOCK NO CLFANOUF COVER I PER DOE m ITT, �"o 14' :Aj To EXCEED IOW BETWEEN EXIST. Po� POILE To BE W E CLEMOUT WE WON CAP R�A7FD BICHN WE SMXAUK. COORDINATE AM No To 5 FT mm AND DETERMINE POLE LOCATION. FMCE -xrar..m. S '10PORTY ME W 12 COVER N 88 SEE NOTE 3 22 22.7 OR 4V DENG 12'* FINISHED GRACE I f . -­ - SCALE : 1"-20' Z r I EN. OF PIPER CHIPPER PLUG T ROOFUNE a, TEST TEE 52 .1 8 p16@m6Wmm6;;;;iI (CHERII 27061 OR APPROAD !25r. C LATERAL SHAM 6 It EQUAL) W 5' 10' 20' 30' 40' [SLOPE - 2% MIN TO SON . VAX SEE NOTES I AND 2 WATER TIGHT CAP F.So SEAER .4V RISEN �o LOCATION SEE NOM 4 T 2 L Il Lo �(AMILY 14EW SINGLE UK V LF-V PVC -,;'I- CLEAN RESIDENCE ------------ V RISER GARAGE T --------- No BASIHAT TO 22.5' OR 45� BEING e ON 6' SIM SEWER 6' W� AND 6' CIT, me ERAL CLEANOUT DETAIL EVENT 1-h 1 1 V TEST TEE l.ft 61 TEE LocKHO Doom 4' ON --------- POSSIBLE 12 SIDE SENOR CLEANOLIT DETAIL SEWEII SEE � 3 UA 1p LEVnING COLLAR bi NOTES, NOTE 4 a R09FI INE L0 1' L ASPHALT SURFACE I. - PIPE SHN_L BE SGR­� AND JDANTS SHALL. BE SINGLE 2M2500115200 GASKERED. /NEW FAMILY 1. WHEN TAPPING ING) EXISTING MAN NOMAD STYLE CB SADDLE SHNUI. PIACEMW OF TEE SHALL DEPEND ON 0. EF,HEY VEBER DEPTH OF SEWER MAN. AS A MINIMUM. THE M SHALI. BE PLACED AT T­U ANGLE FROM PPE SPRING- 1 5 RESIDENCE It 12'k z PIPE SLORE To BE 2X MIN AN. LIP TO EGA �2 Ij I . -122.. Lli 11 . NFF k 2. F NON MAIN IS SONG INSTALLED OR MAN IS BEING REPLACOG. SENVICE CONNECTION To WE MAN SHALL. RE DONE 3. SEWER CILEANCOUT COVER TO HE EAST JORDAN INN WORKS > TOP.* 0 BASEAENT WITH AWM WYESHAI.1.13EATA� DEGFEEANGLE MOM PPESPRINGLINE. LOT 2 01�10� i i i I FOOT LONG 12' PAID , PRODUCT #W3"102 SlAR PIPE �� OR APPRO� < �FW SINGLE FAMI�Y d 3. IF CONNECTING EXISTING PWATE SIDE TO NEW CFY LATERAL A CONCREFLIM SGRONGSACK FORINCO RC SERiEs SLEENE PIPE EQUAL I RESIDENCE r RISER IT OF DRIPPER 4. LEMMING COLLAFI SHALL. BE CONSTRUCTED AS FOLLYNS, PLUG (0101NE 2706 T I r 4. HOPING OF SERVICES WWN RIGHT Or MAY IS NOT ALLOWED. OR APPROVED EQUAL) IN ROADWAYS PER WE STO OWED W-424 .................. ................... / Vz 1 1 5. SHAER PRPE SHALL. m MR-35 AND ATmTs SmAL. BE WKETED, TYPICAL. CLEANDUT IN AREAS, EIMER 24N24NG' CD ................ ......... TYPE V I 1 2 ......... ............... COPPER UNDER ASPHALT OR CONCRETE DEEP COINCRETE OCULAR OR 2r OQWIETOR S' DEEP 4.0* WIM CONClKTE COLLAR I SEE NTEB 4 7.1* 7 --------- ------ G. IF STUD FOR FUTURE DEVELOPMENT. USE RUBBER JOINT B*CUff PLUG OR 07HER APPRONEB WATERTIGHT` PLUM ssoc, GARAGE 'M Lo REVISION! DA REMSION DATE EX. .77 11 CITY OF EDMO C I ITY OF EDMOND �uw "To 'CB NEW LATERAL SEA El SEWER CLEANOUT DETAILS TOP. -10 Pusuc woRks PUBLIC WORKS STANDARD DEPARTMENT NDSI DEPARTMENT E C.B. I DEFAIL �D A. Emmsm APPROVED W. R. DOM SS-200 EX. CBMH 7. - - - - - - - - - - - - .-4.36-12'E 9 ;.- .86-rm PROPERTY LINE �BMH 17/�- 4'. 1 ­CRETE SHED CROE-\ RALW. 10-9.4. MONUMENT MW "X; 1-1--E 1-3/4- B AM DISK IN., -'e. Ll OVER SUPPUED CITY SW MAN -/.4. NEI/. IT SECA . �S. r BG BALL VALVE . . . . WITH 'r EX. M H. Lj 2*PE IP GAS TO__'4I EX C8 Um T, _-ION TDP� 02.5S EX. C.B. EX. M.H. SeE foolre 11 UNE EX. BMH TOP INV. 00.38-6"NW T - - - - - - - - - - - - -IM14 To- IP X. C.B. C N­Ij& 8-W :N.1 3­ T�12159 C STREET RESTORATION W� 11 49--1 CARDS H.lB-12'E 9.22-6SE PER CITY STAN 1..4-.. , DIRECTION I-M-49-12W A OF FLOW EX. C.B. OCISTitC, SrxvxZ Th Wo T%W_jW. NOTES &E awf�--- ay C17Y F 1. ALL UTIUTIES SMALL BE UNDERGROUND. 2. REQUIRED SEPARATION OF UTlUTlES SHALL BE MET PER CITY OF EDMONDS AND INDUSTRY STANDARDS. 0. A MINIMUM OF 3' SEPARATION IS REQUIRED BETWEEN THE DRY @ALL. 1* SERVICES To BE TfPE 'K' SOFF COPPER MIXING (D I* BALL CORP. STOP WTH CC IHIREAD HM AND CQP� (CrS) Mp CUTLET (FORD OR MUELLER) UTIU71ES (POWER. GAS. PHONE, CABLE, ETC.) AND SEWER, wh m Drw �xno WATER, AND STORM; @ WA. PtIRPOSE UNION 70 IbIl IrAUMUl," WITH SH01t7 PLAT P`JLfJZ*17001&'* b. THE REQUIREMENT OF 10' HORIZONTAL SEPARATION FROM WATER MIPT X CIS GRP HALL VALVE CLIFUT STOP EQUAL TO FORD B84-4440 FOR I REPIACNG ��Smm= I' METER SETTER WITH ANGLE BALL METER VALVE ir HIGH WITH DUAL AND SEWER. m '"' AND OUTLET. HORIZONTAL. IN HORIZONTAL, OUTLET EQUAL To FORD V137�15W-11-44 -41A lit.O.W. To Lo-r A-s novmrw Lmss), 3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE SEWER TAP MEN =G " SEAVUfS,- USE SAME AS ABOVE AND ADD A SING117 CHECK EQUAL To FORD VHH7�15W-111-" (ims-mLep r -M PET -r AND INSTALLATION OF SEWER LATERAL WITHIN THE ROW. TAP --To- "IS SEW-A IN VNPAVM EAS: CARSON 1324 MSGCF WIN DUCTILE IBM COVER AND CAST IRON READER DOOR: I" CC 4. THE CONTRACTOR SHALL FIELD VERIFY PIPE SIZE AND INVERT OF IN PAVED AREAS: AMM CAST A6001946PCX12 Box W/ A6=96969 Rm LID EXISTING SEWER LATERAL. AND ADJUST SLOPE OF THE NEW SEWER FOR VACANT LOT (PUTUItE USE) LOCATION MUNWED NTH PANTED e X C STAKE WITH 'WATER' STEN(MUED ON IT LATERAL ACCORDINGL I Y. 14 GA. VINYL COATED WINE TRACER (TAPED TO PLASTIC PIPE EVERY IV) TO BE GROUNDED AT METER AND HOUSE 5. NOT USED. SMEDULE AD 31e OR 1- PL_LIG. REMOVE WON CONNECTION IS MADE 70 CUSTOMER ME WITH COMPIRMION TIMM WATER SERNACE TO HOUSE. INSTALLED BY OWNER/OCNIRACTOR (PER PLUMBING CODE) 6. LOCATION OF THE LANDSCAPE IRRIGAT10M BACKFLOW ASSEMBLY PROPERTY OWNER RESPONSIBLE FOR METER W�H WE M AT MOTT SERVICES TIRE SHALL BE IDEM ID (IF ONE IS PROPOSED). DEPARTMENT: CITY V U. SUPPLY AND 1PLARCUASE. IF USING 3/4- METER. CCINTRALTOR WILL PROVIDE REDUCERS 7. THE 6" CLEANOUT AT THE PROPERTY LINE SHALL HAVE A lr CAST IMUM. SADE OF VIEDIR .. SHALL. HE SET AT THE PAOIE- ME --� APPROM BY WE CITY EN.I.HER. IRON LAMPHOLE COVER NTH 1/2 HEXBOLTS. METER BOXES SHUUl NOT BE SET IN DRIVEWAY AREAS UNLESS TRAFFIC RAYED BOX IS APPROVED CITY ENGINEER. B. THE EXISTING SIDE SEWER WILL NEED TO BE TVd BY THE CONTRACTOR AND VEDIO MUST BE SUBMITTED TO THE CITY FOR REVISION DATE PtECEIVED JANUARY 2010 REVIEW AND APPROVAL TO RE -USE. 3 4" 1 �2 \CITY OF EDMONDS WAT & SERVICE 9. IF THE EXISTING EWER LATERAL IS P0XX== TO BE REUSED, THE- LAT-ITAI PUBLIC WORKS 77ANIARI FEB 2 r INSTALLATION :INIS 64ERAL VaLALM DEPARTMENT V4jV'S,'FPAR� Ta. DETAIL BUILDING TQ DETERMINE 19 ----- - tAf-S 7b I'Ift. WTI* FU 'it. 'd'W0L_-n� Ar THE 2''eP APPROVED UP. R. ENGLISH WA� 130 10. ALL FINAL RESTORATION SHALL BE COMPLETED BY THE lif ON TW' -7- CA ED R� AN tMD IT fl rNA EN 'Cn OR APPROVET CONTRACTOR. -LOT 11. A MINIMUM OF 18' OF VER71CAL CLEARANCE IS REQUIRED BETMN SEWER AND STORMWAIIER LINES AT CROSSINGS. WATER, SEWER AND UTILITY PLAN 12. INSTALL A STORZ ADAPTER ON -THE FIRE HYDRANT. FOR FAIRWINDS DEVELOPMENT �5P IN NW1/4, NE1/4 SEC. 25, T.27N., R.3E.,W.M. LEGAL DESCMp-nON (EN-nRE PROPERTY) PARCEL A OF CITY OF EDMONDS SHORT PLAT NO. S-9-61A. RECORDED UNDER BENCH MARK RECORDJ 0 NO. 9102140373. RECORDS OF SNOHOMISH COUNT(, WASHINGTON, BEING A PORTIONNOF THE NORTHWEST QUARTER OF THE NORTHEAST QUARTER OF SECTION 25, TOP OF BRASS DISK AT THE INTERSECTION OF 9ti­i AVENUE S. AND PINE UTILITY NOTE TOWNSHIP 27 NORTH. RANGE 3 EAST, W.M. , STREET. THE LOCATION OF UNDERGROUND U71LITIES SHOWN HEREON IS TOGETHER WITH LOT A. CITY OF EDMONDS LOT UNE ADJUSTMENT NO. UL-2006­100, ELEVATION : 100.00 APPROYAMATE ONLY. THIS SURVEY DOES NOT PURPORT TO SHOW THE RECORDED UNDER AUDITOR'S FILE NO. 200609115184. RECORDS OF SNOHOMISH COUNTY, LOCATION OF ALL LITIUTIES. THE OWNER SHOULD CONTACT THE WASHINGTON, BEING A PORTION OF THE NORTHWEST QUARTER OF THE NORTHEAST DATUM : ASSUMED PURVEYORS OF ALL UTILITIES IN THE AREA TO DETERMINE THE QUARTER OF SECTION 25. TOWNSHIP 27 NORTH, RANGE 3 EAST, W.M.; LOCATION AND DEPTH OF ALL UTILITIES ON AND ADJACENT TO THE PROPERTY. SITUATE IN THE COUNTY OF SNOHOMISH STATE OF WASHINGTON CITY OF EDMONDS SNOHOMISH COUNTY, WASHINGTON WS. REVISED PER CITY REVIEW COMMENTS, DAIM 4-20-18 �ffm% Lovell-Sauerland Associates, Inc. SMT En&eers/Sumyors/Plaimers/Develol)ment Consultants 35420 e-.maii: bdo@lsaen&eering.com - web: hatengineering.com C6 19217 36th Avenue W., Suite 106 * Lynnwood, WA 98036 - (425)775-1591 09 NO B. M . TOP OF NORTHERLY BOLT ON FIRE HYDRANT LOCATED T NOTH Of DRILIN DATIC I F.B. THE SOUTHWEEST PROPERTY CORNER 0l/rl/?_OIS aT.T. 7-10-17 539. P.57 1 77-0-17 .7 Cm'm 56 I j ,,ORM WAN114 Son 11 11 1'14"T ON ERASE I IN. > 0) PLACE SIGN AT NW V CORNER OF INTERCECTION EX. CBMH,(�--' EASTBOUND F.P-99 4. PEDESTRIANS R-61-In SW CORNER. NNR/4. MEI/4 SE" N �1. 3. RAES DIM AM 'X* EX. M 1H. r . VOP-I.D.41 INV�. _N __ G . M194.11-1 -E B COORDINATE CONSTRUCTION TO KEEP STREETS OPEN Imm �m, N W*E S SCALE : 1"�20' 0' 5' 10' 20' 30' 40' ,,ROOF PEAK ELEVATION: ­6 2703250 104M INO.AS E. MT 2�2 0113200 STESART .. SCHA- 1ROP. �n_L88-p2'27" 21E LOT 3 --LPROP. 10' SEWER EASEMgNT t& I FOR LOTS 2 AND 3 2 (D SO 7 7- _EX.C.. SECTION 25, T.27N., R.3E., W.M. ,�o.l PE.: -ROGF PEAK S�ATKI 141.7 ­14- WORK AREA TEMP. CONST. ENTRANCE ARI.OY . -IR DAVID ---------- 4---- ONE Eb :LQ IROPERP� UIa� 5FTNOD ma'." , 1.51 WEST 2-M M� H ­212� ,ffmL(- BUFFERDATA LONGITUDINAL BUFFER SPACE� B 4.0 BUFFERVEHICLE ROLL AHEAD DISTANCE R �MRTAM ­R To -IRRARE-G.S. No SPKIRRED WMCE RM.N. ­2 x x HE LINE ROAD AHEAn > WORK LEGEND FLAGGING STATIO TEMPORARY SIGN I_GCATION P.Mm-cuE BE PRE VPA STS V­Ta(aPTI MAL IF M MPH OR UESS) IFOMPHORLESS) ...MP. 4 Ir ROAD 25MPHOR.SS 1. 2 Do BE -OOMM-Te PREI WORK URMNAREASTOW To STM`// AHEAD B� < W20.TB W20-1 BP 4.. W 'W W014 6W ES -TA a X x X x !I I'a"o- W��TA _( BE "I PREPARED > Tosmp// NAL mp� _-­'._T�NGENT 12�. NS - I SO E ONE LANE W20-78 WAS x -IONS-EB KONOP�GR! W20.1 2. EUENDNG THE DNANNEIAVIG DEnCe WER ADMISS -RISIREGOINIIENDED. 3. NIGHT NKREQVIRESADD1TGMRWMYUGHT­ 1. ONS. .-E.M.N..."IDAVONS ONE -LANE, TWO-WAY TRAFFIC CONTROL ADD- Dmu WITH FLAGGERS 4. BEE SPEDIAL PROMONS MR -KNOLIR RESTIUDMONS. NOTTOWALE IQ -x (1) MINIMUM SHOULDIERTAPIR LENGTH - L136WO CHANNELIZATI DEVICE .-IN I MM SPACINGRael) PorM Snnd (MPh) _EN -.PH W-M 30 35 0 50 a as M DO AD SO SO 10 1 - i A 3 0� � FOR SHOIJUDERS T 981h AVENUE W. FOR WESTBOUND PEDESTRIANS BUFIFER BATA LONGITUDINAL BUFFER SPACE - IS SPEEDWPID 25 1 N N Q 0 ED OENGM (.q IS SUFFERVEHICLEROLLAHEADOWANCE-R IDOFEBTG� ­EA1M-GS­-­H­ OS_ RE.M. T r//// a_gBMH/ x x "R M_ �W$ �AD­"W < W20.1 AHEAD LEGEND NO - SHOULDER CLOSURE - LOW SPEED 1, MMMSPAOINGFORTHEDORMSMEANTAPERS-20'. (40 MPH OR LESS) AIL SO. ARE S-1 ON LEGAL DESCRIPTION (ENTIRE PROPERTY) L= 196TH ST SW _ 3� NO FI.AOGERS OR SI-ERS, PARCEL A OF CITY OF EDMONDS SHORT PLAT NO. S-9-61A, RECORDED NTROL PLAN NOTES: �r. S.R. 52T_ E;3 CPR"G=1=' CLE NOTTOSCAU UNDER RECORDING NO. 9102140373 , RECORDS OF SNOHOMISH COUNTY. CASPERS ST W WASHINGTON BEING A PORTION 0 E NORTHWEST QUARTER OF THE F1C CONTROL < NORTHEAST bUARTER OF SECTION'21H TOWNSHIP 27 NORTH. RANGE 3 EAST. 1.1 LL TRAFFIC CONTROL ALL COMPLY NTH THE MANUAL ON UNIFORM TRAF /DE\nCESr(MUTCD) ST, SDH W.M. STAN ARDS. TOGETHER WTH LOT A. CITY OF EDMONDS LOT LINE ADJUSTMENT NO. GO 09115184. RECORDS Z FLAGGER(S), BARRICADES AND SIGNS SHALL CONFORM To THE STANDARDS ESTABLISHED I THE 3. LL_ 06-100, RECORDED UNDER AUDITOR'S FILE NO. 2006 (MUTCD).. , BEING A PORT10N OF THE NORTHWEST S22 LATEST EDITION OF THE 'MANUAL ON UNIFORM TRAFFIC CONTROL DEACES" (MUTCD). OF GNOMISH COUNTY, WASHINGTON AIN ST QUARTER OF THE NORTHEAST QUARTER OF SECT10N 25, TOWNSHIP 27 NORTH. GEAR RANGE 3 EAST, W.M.; 3. ALL FLAGGERS ARE TO BE EQUIPPED WITH ORANGE SAFETY VESTS AND HEAD GEAR APPROPRIATE FOR FLAGGING TRAFFIC WITHIN THE PUBLIC RIGHT-OF-WAY AND SHALL H DAYW�TM"OMN ST SITUATE IN THE COUNTY OF SNOHOMISH, STATE OF WASHINGTON. VAUD FLAGGING CARDS FROM THE DEPARTMENT OF LABOR AND INDUSTRIES. 12TH LETED AT THE END OF EACH D THE 3C L_ o-r 4. AFTER WORK WITHIN THE TRAVELED ROADWAY IS COMP OUT 114E ROAD SHALL BE COMPLETELY OPEN TO TRAFFIC AND ALL EQUIPMENT SHALL BE OR C TRAFFIC CON OL/SIDEWAK CLOSURE & HAUL ROUTE PLAN TRAVELED ROADWAY. ALL NONAPPLICABLE SIGNS SHALL BE REMOVED. TURNED RED PINE ST DAILY WHEN CONDITION NO LONGER EXISTS. 216th ST SW HAUL ROUTE BENCH MARK 16 OF BRASS DISK AT THE INTERSECTION OF 9th AVENUE S. PINE 5. ACCESS BY EMERGENCY VEHICLES SHALL BE MAINTAINED AT ALL TIMES. FOR STREET. 6. CONSTRUCTION SIGNS AND DEUNEATORS SHALL BE PROVIDED AND MAINTANED BY THE 220TH ST SIN ELEVATION : 100.00 CONTRACTOR. FAIR S DE VEL OPMEN T SP DATUM : ASSUMED 7. APPROVED TRAFFIC CONTROL SIGNS AND MARKINGS ON PRIVATE PROPERTY SHALL BE P VIDED, I Z7 INSTALLED AND MAINTAINED BY THE PROPERTY OWNER. IN NW1/4, NE1 SEC. 25, T.27N., R.3E.,W.M. T.B.M. TOP OF NORTHERLY BOLT ON FIRE HYDRANT L ATED FEET NOTH OF 1HE SOUTHWEST PROPERTY CORNER 8. TRAFFIC CONTROL PLAN IS SUBJECT TO CHANGE PRIOR TO CONSTRUCTION. CIT F EDMONDS 9. ADDITIONAL SIGNING AND FLAGGING MAY BE REQUIRED AS CONDITONS WARRANT. PPROVED FOR CONSTRUCTION 'zN( 'SH C . . . . . ,TY, WASHINGTON 10. SHOULD A PROPOSED SIGN LOCATION FALL WITHIN A PRIVATE DRIVEWAY. CONTRACTOR TO HAUL ROUTE MAP CITY OF EDMONDS ADJUST LOCATION OF SIGN TO FALL 5'+ 13EYOND EDGE OF DRIVEWAY IN DIRECTION OF ROAD W.K_ PER CITY REVIEW COMMENTS, DATED 4-20-18 07/10) U11LITY NOTE TRAFFIC. (10' MAX. FROM PLAN LOCATION). DRIVEWAY ACCESS SHALL BE MAINTAINED AT ALL NOT TO SCALE W REVISED THE LOCATION OF UNDERGROUND UTILITIES SHOWN HEREON IS TIMES, DATE-' APPRO IMATE ONLY. THIS SURVEY DOES NOT PURPORT TO SHOW THE 11. ALL EQUIP ENT AND MATERIALS REQUIRED FOR TRAFFIC CONTROL SHALL BE FURNISHED, Lovell-Sauerland & Associates, Inc. S11 L c TIX MAND MAINTAINED BY THE CONTRACTOR To THE SATISFACTION OF THE CITY Engineers/Surveyors/Plaimers/Development Conl� 0 A ON OF ALL UTILITIES. THE OWNER SHOULD CONTACT THE INSTALLED By. �,_JN - PURVEYORS OF ALL UTILITIES IN THE AREA TO DETERMINE THE INSPECTOR OR ENGINEER. 35420 C LO e-mail: info@lsaetLgineering.com - web: Isaengineering.com. P CATION AND DEPTH OF ALL UTIUTlES ON AND ADJACENT TO THE C6 ENGINEERING DIVISION -1591 ROPERTY. 19217 36th Avenue W., Suite 106 - Lynnwood, WA 9BO36 (425)775 I I