Heating_System_Sizing_Worksheetbimme Heatina bmem bite: wasnlnaton State Please fill out all of the green drop -downs and boxes that are applicable to your project. As you make selections in the drop -downs for each section, some values will be calculated for you. If you do not see the selection you need in the drop -down options, please call the WSU Energy Extension Program at (360) 956-2042 for assistance. Project Information Contact Information PAUST RESIDENCE H2D ARCHITECTURE & DESIGN 825 MAIN STREET, EMONDS, WA 98020 1HEIDI HELGESON: 206-542-3734 71 KIRSTEN.PAUST@FORTIVE.COM HEIDI@H2DARCHITECTS.COM Heating System Type: O All Other Systems ® Heat Pump To see detailed instructions for each section, place your cursor on the word 'Instructions". Design Temperature Instructions Design Temperature Difference (AT) Etlmands AT = Indoor (70 degrees) - Outdoor Design Temp Area of Building Conditioned Floor Area Instructions Conditioned Floor Area (sq ft) 3,465 Average Ceiling Height Conditioned Volume Instructions Average Ceiling Height (ft) 8.0 27,718 Glazina and Doors U-Factor X Area = UA Instructions L u-azs . 1 0.250 1,090 272.53 Skylights U-Factor X Area = UA Instructions 0.50 Insulation Attic U-Factor X Area = UA Instructions R-49 V 0.026 673 17.49 Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA Instructions R-38 Vented V 0.027 454 12.25 Above Grade Walls (see Figure p U-Factor X Area UA Instructions R-21 Intermediate . 0.056 2,584 144.70 Floors U-Factor X Area UA Instructions No Floors above unconditioned spaces. r Below Grade Walls (see Figure 1) U-Factor X Area UA Instructions NO Below Grade Walls in this project. 0.028 Slab Below Grade (see Figure a F-Factor X Length UA Instructions No Slab Below Grade in this project. V i 0.303 --- Slab on Grade (see Figure 1) F-Factor X Length UA Instructions No Slab an Grade in this project. V J --- Location of Ducts Instructions Duct Leakage Coefficient Conditioned Space • 1.00 Figure 1. Above Grade 46 Sum of UA 446.97 Envelope Heat Load 20,561 Btu / Hour Sum of UA X AT Air Leakage Heat Load 13,770 Btu / Hour VolumeX 0.6XATX.018 Building Design Heat Load 34,331 Btu / Hour Air Leakage + Envelope Heat Loss Building and Duct Heat Load 34,331 Btu / Hour Ducts in unconditioned space: Sum of Building Heat Loss X 1.10 Ducts in conditioned space: Sum of Building Heat Loss X 1 Maximum Heat Equipment Output 42,913 Btu/Hour Building and Duct Heat Loss X 1.40 for Forced Air Furnace Building and Duct Heat Loss X 1.25 for Heat Pump (07101113)