APPROVED BLD PLN-BLD2020-0250 Architectural Drawings 6-15-20 (2)Evans Residence
SITE &ZONING DATA
BUILDING CODE
FIRE, INSULATION, ENERGY CODE
DRAWING LIST
PROJECT SUMMARY:
NEW SINGLE FAMILY RESIDENCE w/ ATTACHED 3 CAR GARAGE
PROJECT ADDRESS:
20018 83RD AVE W
EDMONDS, WA 98026-6726 '
t_��--��--���j�
PROJECT OWNER:
MARNE & SIMON EVANS
20020 83RD AVE W
EDMONDS, WA 98026-6726
CONTACT: SIMON EVANS
ASSESSORS PARCEL NUMBER:
TO BE SUBMITTED BY OWNER UPON RECORDING BY
SNOHOMISH COUNTY
LEGAL DESCRIPTION:
LOT 1 of PLN20180037
� � _ �1
PROJECT ZONING:
SINGLE FAMILY RS-8
� LOT SIZE
GROSS LOT AREA : 0.26 ACRE (11,731 S.F.)
� EASEMENT AREA: 0.06 ACRE (2889.7 S.F.)
� NET LOT AREA (w/o Easement) : 8841.3 S.F.
� LOT COVERAGE -
26.4% (35% MAX LOT COVERAGE ALLOWED. -
� THIS LOT COVERAGE AREA (2334 SF) INCLUDES HOUSE
FOOTPRINT (INCLUDING PORCHES) AND GARAGE FOOTPRINT
1
BUILDING HEIGHT:
24' 4-1/2" (ROOF RIDGELINE) ABOVE AVERAGE EXISTING GRADE.
SEE ELEVATION DRAWINGS ON SHEET A-3.1 FOR BUILDING
HEIGHT.
CUT AND FILL:
REFER TO CIVIL ENGINEERING DRAWINGS FOR CUT AND FILL
CALCULATIONS
CRITICAL AREAS /WETLANDS
AN EROSION HAZARD IS PRESENT AS IDENTIFIED IN
� CRA2020-0043
T
LOT EASEMENTS:
THIS PROPERTY WAS SUBDIVIDED FROM AN EXISTING
LOT. THE NEW LOT HAS TWO EASEMENTS THAT BENEFIT
THE EXISTING LOT AT THE REAR OF THE SITE. THESE
TWO EASEMENTS ARE FOR ACCESS (@ NORTH SIDE OF
LOT) AND A SEWER LINE (@ SOUTH SIDE OF LOT).
BUILDING SETBACKS:
FRONT YARD (MIN. 25')
SOUTH SIDE YARD SETBACK (15') /NORTH SIDE YARD
SETBACK (7'-6" FROM ACCESS EASEMENT) / REAR YARD
(15')
PARKING CALCULATIONS
THIS RESIDENCE HAS THREE SPACES (19' x 8'-6") IN AN
ATTACHED GARAGE AND TWO SPACES IN THE DRIVEWAY.
SITE WORK:
REFER TO CIVIL ENGINEER'S PLANS FOR SCOPE AND
AREAS OF ALL SITE GRADING AND UTILITY PLANS
IMPERVIOUS SURFACE CALCULATIONS:
TOTAL IMPERVIOUS AREA : 3349 S.F.
(SEE CALCULATIONS ON SITE PLAN @ SHEET A-1.3)
SITE DESIGN DATA
(SEE STRUCTURAL DRAWING SHEET S-1.1 FOR COMPLETE
DESIGN LOADS CHART
SEISMIC: SEISMIC DESIGN CATEGORY: D
WIND:110 MPH
WIND EXPOSURE: C
SNOW LOADS 25 PSF
DESIGN LOADS PER CHAPTER 3 OF 2015 INTERNATIONAL
RESIDENTIAL CODE
TABLE R301.2(1)
CLIMATICAND GEOGRAPHIC DESIGN CRITERIA
SUBJECTTD
DAMAGE
FRAM
ICE 5HEILD
GROUND
WIND
SEISMIC
Frast
WATER
UNDER-
AIR
MEAN
SNOW
SPEEDe
DESIGN
line
DE51GN
LAYMENT
FLOOD
FREEZING
ANNUAL
LOAD
(mph}
CATEGDRYg
Weatheringa
depths
Termite`
Decays
TEMPT
REQUIRED'
HAZARDS"
INDEX'
TEMPk
Slight to
Firm Maps
25 psf
85
❑1
Moderate
25��
5 to M
27° F
No
0-1,D00
5fl'
Mode rate
11-8-99
APPROVED BY PLANNING
t.
���
Jul 06 2020 PLANS MUST B E
OBTAIN ELECTRICAL PERMIT FROM
STATE LABOR &INDUSTRIES O N JOB SIT E
ALL WORK SUBJECT
TO FIELD
INSPECTION F R
CODE COMPLIANCE
APPROVED
CITY OF EDMONDS
BUILDING DIVISION
APPROVED PLAN
CODE COMPLIANCE:
THIS RESIDENCE SHALL BE CONSTRUCTED TO PROVIDE FULL COMPLIANCE T0: THE 2015 INTERNATIONAL
RESIDENTIAL CODE WITH STATE AMENDMENTS, 2015 INTERNATIONAL MECHANICAL CODE (INCLUDING
INTERNATIONAL FUEL GAS CODE) WITH STATE AMENDMENTS, 2015 INTERNATIONAL FIRE CODE WITH
STATE AMENDMENTS, 2015 UNIFORM PLUMBING CODE WITH STATE AMENDMENTS, 2015 WASHINGTON
STATE ENERGY CODE (WAG 51-11).
DEFERRED SUBMITTALS:
ALL DESIGN -BUILD DRAWINGS AND APPLICATIONS FOR THE FOLLOWING PERMITS WILL BE SUBMITTED BY
THE GENERAL CONTRACTOR AT A LATER DATE:
a) ELECTRICAL, b) MECHANICAL, c) PLUMBING,
d) WATER METER, e) SIDE SEWER.
BUILDING CODE
2015 INTERNATIONAL RESIDENTIAL CODE
ENERGY CODE
2015 WASHINGTON ENERGY CODE W/PRESCRIPTIVE PERFORMANCE
OCCUPANCY GROUP
R-3
CONSTRUCTION TYPE
TYPE V-B
BUILDING HEIGHT
SEE SHEET A-3.1 OF THIS SET OF DRAWINGS FOR PROPOSED BUILDING HEIGHT OF 24' 4-1/2".
SEPARATIONS
THERE IS AN ATTACHED GARAGE TO AT THIS RESIDENCE
SEE GARAGE/LIVING AREA SEPARATION NOTES ON SHEET A-2.1 AND A-4.1.
WALL RATINGS AT DETACHED SINGLE FAMILY RESIDENCES
INTERIOR BEARING &NON -BEARING WALLS: NO RATING REQUIRED
EXTERIOR BEARING WALLS: NO RATING REQUIRED
EXTERIOR NON -BEARING WALLS: NO RATING REQUIRED
CEILINGS -FLOORS: NO RATING REQUIRED
SEE GARAGE/LIVING AREA SEPARATION NOTES ON SHEET A-2.1 AND A-4.1.
STAIRWAY /STEPS CONSTRUCTION
WOOD CONSTRUCTION W/WOOD RISERS AND TREADS.
SEE STAIR NOTES ON SHEET A-4.1 FOR ADDITIONAL INFORMATION.
ACCESSIBLE UNITS
PER THE 2015 INTERNATIONAL RESIDENTIAL CODE, SINGLE FAMILY RESIDENCES ARE NOT REQUIRED TO
BE ACCESSIBLE UNITS AS DEFINED BY THE ACCESSIBILITY SECTION OF THE CODE.
RECYCLE &GARBAGE STORAGE AREAS
THIS RESIDENCE WILL STORE GARBAGE AND RECYCLE MATERIALS IN BINS WITHIN THE GARAGE.
HAZARDOUS MATERIAL
THIS IS A RESIDENTIAL PROJECT AND NO HAZARDOUS MATERIAL WILL BE HANDLED OR STORED AT THIS
PROJECT.
INSULATION VALUES
PER WASHINGTON STATE ENERGY CODE ,THE INSULATION VALUES ARE R-21 FOR WALLS, R-38 FOR
FLOORS OVER UNHEATED SPACE, AND R-49 IN ATTIC SPACE.
HEATING &HOT WATER SYSTEM
THIS RESIDENCE SHALL BE HEATED BY A HIGH EFFICIENCY GAS FIRED FURNACE HEATING SYSTEM WITH
FRESH AIR INTAKE FOR WHOLE HOUSE VENTILATION AND FRESH AIR INTAKE FOR COMBUSTION AIR.
HOT WATER SHALL BE PROVIDED BY A GAS FIRED HIGH EFFICIENCY WATER HEATER PER ENERGY CODE
CALCULATIONS ON SHEET A-6.1
GLAZING U-VALUES
ALL WINDOWS /GLAZING SHALL HAVE A U-VALUE OF 0.28
WASHINGTON STATE ENERGY CODE
SEE SHEET A-6.1 FOR CALCULATIONS AND ENERGY CODE OPTIONS SELECTED FOR THIS RESIDENCE
AIR LEAKAGE TESTING
REFER TO SHEET A-2.3 FOR NOTES ON AIR BARRIER /AIR INFILTRATION. AIR LEAKAGE TESTING SHALL BE
PERFORMED PER WASHINGTON STATE ENERGY CODE SECTION R402.4
DUCT TESTING
DUCT TESTING SHALL BE PERFORMED PER WASHINGTON STATE ENERGY CODE SECTION R403.3
City Of Edmonds
Building Department
Work
NEW SFR
Address
Owner
Approved Date
7/06/2020
Building Official
Permit Number BLD2020-0250
FIRE PROTECTION SYSTEM
THIS RESIDENCE IS NOT REQUIRED TO BE FIRE SPRINKLERED.
INSULATION DATA /ENERGY CODE REQUIREMENTS
INSULATION VALUES DETERMINED BY PRESCRIPTIVE APPROACH PER 2015
WASHINGTON ENERGY CODE.
THIS HOUSE WILL BE HEATED WITH GAS FIRED FURNACE PROVIDING WARM AIR
THROUGH METAL DUCTS TO VENTS AND HAS A THERMOSTAT FOR TEMPERATURE
CONTROL. REFER TO THE ENERGY CODE CALCULATIONS FOR REQUIRED
INSULATION VALUES.
CONSTRUCTION EROSION CONTROL
CONSTRUCTION EROSION CONTROL MEASURES MUST BE IN PLACE AND
APPROVED BY BUILDING DEPARTMENT PRIOR TO ANY EARTH DISTURBANCE. CALL
BUILDING DEPARTMENT TO SCHEDULE AN INSPECTION APPOINTMENT FOR THIS
ITEM.
ADDRESS SIGNAGE
TEMPORARY ADDRESSING OF THE RESIDENTIAL UNITS SHALL BE CLEARLY VISIBLE
FROM THE PUBLIC RIGHT OF WAY PRIOR TO CONSTRUCTION OF COMBUSTIBLE
MATERIALS.
PERMANENT ADDRESSING OF THE RESIDENTIAL UNIT SHALL BE CLEARLY
VISIBLE FROM THE PUBLIC RIGHT OF WAY ON PRIOR TO CERTIFICATE OF
OCCUPANCY. BUILDINGS SHALL HAVE
APPROVED ADDRESS NUMBERS, BUILDING NUMBERS OR
APPROVED BUILDING IDENTIFICATION PLACED IN A POSITION THAT IS PLAINLY
LEGIBLE AND VISIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY.
THESE NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND.
ADDRESS NUMBERS SHALL BE ARABIC NUMBERS OR ALPHABETICAL LETTERS.
NUMBERS SHALL BE A MINIMUM OF 4 INCHES (102 MM) HIGH WITH A MINIMUM
STROKE WIDTH OF 1/2 INCH (12.7 MM). WHERE ACCESS IS BY MEANS OF A PRIVATE
ROAD AND THE BUILDING ADDRESS CANNOT BE VIEWED FROM THE PUBLIC WAY, A
MONUMENT, POLE OR OTHER SIGN OR MEANS SHALL BE USED TO IDENTIFY THE
STRUCTURE.
SUBMITTALS
THE FOLLOWING NOTES SHALL SERVE AS A GUIDE TO THE CONTRACTOR TO VERIFY
EACH CONDITION WITH THE PRODUCT MANUFACTURER OR SUPPLIER, AND/OR LOCAL
JURISDICTIONS FOR THEIR REQUIREMENTS PRIOR TO SUBMITTING A BID TO THE OWNER
OR PROCEEDING WITH WORK.
THE ITEMS OUTLINED BELOW ARE NOT NTENDED TO BEAN EXHAUSTIVE ANALYSIS OF
ALL POSSIBLE AREAS OF CONCERN OR CONFLICT, BUT RATHER TO SERVE AS A
BEGINNING POINT IN IDENTIFYING COMMONLY OVERLOOKED AREAS IN THE
CONSTRUCTION PROCESS.
1. REVIEW MANUFACTURER'S PRODUCT LITERATURE FOR INSTALLATION INSTRUCTIONS
UNIQUE TO THE PROJECT CONSTRUCTION TYPE.
A. HVAC EQUIPMENT AND DUCTING
B. RECESSED AND SEMI -RECESSED LIGHTING
C. ALL EXHAUST FANS AND DUCTING
D. BATH TUB AND SHOWER ENCLOSURES
E. RECEPTACLE BOXES (I.E., T.V., TELEPHONE, ELECTRICAL, PLUMBING)
2. COORDINATE WITH THE FOLLOWING UTILITIES AND COMPLY
WITH LOCAL JURISDICTIONAL REQUIREMENTS.
A. GAS UTILITY
B. TELEPHONE UTILITY
C. CABLE T.V. UTILITY
D. POWER UTILITY
E. TRASH SERVICE
F. LOCAL UTILITY DISTRICT
FOR:
1. SANITARY SEWER
2. WATER SUPPLY
4. THE FOLLOWING ITEMS SHALL BE DESIGN/BUILD SYSTEMS. AND SHALL BE APPLIED
FOR BY THE CONTRACTOR AT A LATER DATE. THE CONTRACTOR SHALL PROVIDE A
COMPLETE SYSTEM TO THE OWNER, WHICH COMPLIES WITH ALL JURISDICTIONAL
REQUIREMENTS.
1. BUILDING ELECTRICAL
2. PLUMBING SYSTEM
3. MECHANICAL /HEATING SYSTEM
ARCHITECTURAL
A-1.1 PROJECT DATA, SITE PLAN &COVER SHEET NOTES
A�1�2, �---� �-�PROJEC� GENERA�NOTES �, --
i A-1.3
THIS SHEET WAS DELETED. SEE CIVIL ENGINEERS SITE, PLAN
A-1 4'�'�
3-G MASSING VIEWS 1�`�"`-
A-2.1
BASEMENT FLOOR PLAN
A-2.2
LEVEL 1 FLOOR PLAN
A-2.3
LEVEL 2 FLOOR PLAN
A-2.4
ROOF PLAN
A-2.5
LEVEL 1 &BASEMENT LIGHTING PLAN
A-2.6
LEVEL 2 LIGHTING PLAN
A-3.1
EXTERIOR BUILDING ELEVATIONS -SOUTH &EAST
A-3.2
EXTERIOR BUILDING ELEVATIONS -NORTH &WEST
A-4.1
NORTH BUILDING SECTION &NOTES
A-4.2
SOUTH BUILDING SECTION &NOTES
A-4.3
ENTY PORCH SECTION &PORCH COLUMN PLAN
A-4.4
LEVEL 2 PORCH SECTION DETAILS &INTERIOR DETAILS
A-5.1
DOOR &WINDOW SCHEDULE, DETAILS &LEGENDS
A-6.1
WASHINGTON STATE ENERGY CODE CALC'S.
PLEASE SEE STRUCTURAL DRAWINGS FOR LIST OF STRUCTURAL DWGS.
AREA CALCULATIONS
BUILDING AREA CALCULATIONS
LEVEL 1 FLOOR AREA (HEATED)
LEVEL 2 FLOOR AREA (HEATED)
BASEMENT FLOOR AREA (HTD)
TOTAL FLOOR AREA (HEATED)
ENTRY PORCH
DINING /KITCHEN PORCH
BASEMENT PATIO
SITE AREA CALCULATIONS
LOT SIZE
FOOTPRINT
LOT COVERAGE
1168 S.F.
1108 S^F.
764 S.F.
226 S.F.
141 S.F.
163 S.F.
11,731 S.F
2299 S.F.
19.6%
IMPERVIOUS AREA CALCULATIONS
COVERED ROOF AREA 2616 S.F.
SIDEWALKS, DRIVEWAY 733 S.F.
TOTAL IMPERVIOUS AREA 3349 S.F.
Project Site
20018 83rd Ave W
{
p L1,MrCC Qt = ,152A
5z4
�
b
�. �.
�Qth �t Svc
Gaspers St z°°rn sc ��
A
zUlSeh s[ sw
z
`m � 2flOZEi 83rd
� A'fe W
52A
�
��nnno;vns �Pu
y
�
st -t _
Main St. ,Main SL
��
�
.�
�
q
� Dayton St yQS�
�
�
�
� Memorial
�
e
� Alder St :�-w;;b:.�.
�,:PRfk
!
�
'Walnuts[
�
v � tedarst
fl
��
�
w- � � y S
°�tlofn
�
m
taa
r:, � �, � �`ay
ro
�
�
fC �
p
{
!'F
�
'-^ Pine St. � � 21$th 5[ 5w 3
�� a n � 297th St S'+'�
�
�
0
- �
F
�
q � Fir $C � � � 218tF� 54 SW �
`n
218Ch Si SW
�
a
a y
dW
.�
SITE LOCATION MAP
PROJECT TEAM
OWNER
SIMON &MARNE EVANS
20020 83rd Ave. W.,
EDMONDS, WA 98026
Tel: ��
Fax:
Contact: SIMON EVANS
ARCHITECT
CARL J. COLSON -ARCHITECT PLLC
23623 20TH AVE W.
BOTHELL, WA 98021
Tel: (425) 806-3703
Fax: -
Contact: CARL COLSON
w
����
�oDtFI st � -Project
Site
y 20018
� � 83rd
'�� Ave W
2DD20 $3rsl •;:
rove YID
AREA VICINITY MAP
STRUCTURAL ENGINEER
SIDESWAY ENGINEERING
20305 87th AVE. W
EDMONDS, WA 98020
Tel: (425) 673-4160
Fax:
Contact: CHRIS BERNARDS, P.E. / S.E.
CIVIL ENGINEER
WESTERN ENGINEERS, INC.
9740 EVERGREEN WAY
EVERETT, WA 98204
Tel: (425) 356-2700
Fax: .
Contact: JESSE JARRELL
RESUB
Jun 15 2020
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
W
�+
Carl J. Colson -Architect
PLLC
23623 20th Ave. W
Bothell, WA 98021
425-806-3703
wwwCarlColsonArchitect. com
Commercial &Residential
Architecture
Evans Residence
Probe t Address
20018 83rd Ave. W.,
Edmonds, WA 98026
New SFR at 20018 83rd Ave. W (Lot 1 of
PLN20180037)
City of Edmonds Permit #: BLD2020-0250
Project Client
Marne &Simon Evans
20020 83rd Ave. W.
Edmonds, WA 98026
Sheet Title
Cover Sheet
Pro' a ct D ata
l
7543 REGISTERE
ARCHITECT
��` '
CARL J. COLSON
S ATE OF WASHINGTO
ISSUED FOR PERMIT 1-21-2020
Document Set Type:
Revision Schedule
Rev.
# Date Description
1 16-15-2020 I Add Window /Permit Revisions
DRAWING USE NOTIFICATION
This set of drawings is being issued as a Progress or Permit Set of Drawings
and is subject to change and adding of additional information and
drawings as required by review of the Building Department in the
jurisdiction where this project is located.
DO NOT USE THIS DRAWING FOR CONSTRUCTION UNLESS THIS
DRAWING HAS A BUILDING DEPARTMENT "APPROVED" STAMP
APPLIED BY THE BUILDING DEPARTMENT UPON COMPLETION OF
THE PERMIT REVIEW PROCESS.
Do not use this drawing for Bidding or Estimating Purposes unless
authorized by Client. During Construction Phase, the Clients General
Contractor (Builder) or Developer shall be responsible for ensuring that all
Construction Personnel of the General Contractor and all Subcontractors
are supplied with all AppYOUCG� and most current documents.
ARCHITECTURAL COPYRIGHT
This sheet of drawings may not be reproduced in any form without prior
approval of Carl J. Colson -Architect PLLC.
These document, the ideas, and designs incorporated herein as an
instrument of service shall remain the property of Carl J. Colson -Architect
PLLC and are solely for the use on this project only. These files, drawings,
ideas, or designs may not be tramsmitted electronically without express
permission of Architect. They are not be used by the client or any other
party or entity on other projects, in whole or part, or as an extension to this
project except by agreement in writing with appropriate financial
compensation to Carl J. Colson -Architect PLLC.
Copyright Carl J. Colson -PLLC, 2019. All rights reserved.
Project Number
Sheet Issue Date �
03/13/13 •
Drawn By
Author Cover Sheet -Project Data
Scale
As indicated Sheet Plot Dat�/14/2020 7:31:53 PM
www.CarlColsonArchitect.com
GENERAL NOTES FIRE SAFETY ISSUES CASEWORK, PRESSURE TREATED WOOD, &FINISHES
1. NOTIFY THE ARCHITECT OF ANY DISCREPANCIES THAT EXIST WITHIN THE 1. FIRE BLOCKING SHALL BE REQUIRED AT ALL LOCATIONS REQUIRED BY THE 2015 1. ALL PAINT AND LIKE FINISHES SHALL BE APPLIED IN ACCORDANCE WITH THE MANUFACTURER'S
DRAWINGS. INTERNATIONAL RESIDENTIAL BUILDING CODE. RECOMMENDATIONS.
2. ALL METHODS, MATERIALS, AND WORKMANSHIP SHALL CONFORM TO THE 2015 2. ALL BEDROOMS SHALL HAVE WINDOWS THAT COMPLY WITH 2O15 INTERNATIONAL 2. CARPET CONTRACTOR SHALL FURNISH AND INSTALL RUBBER REDUCER STRIPS AT ALL LOCATIONS
INTERNATIONAAL RESIDENTIAL BUILDING CODE. RESIDENTIAL BUILDING CODE EGRESS REQUIREMENTS. REFER TO WINDOW SCHEDULE WHERE CARPET AND RESILIENT FLOORING MEET. PROVIDE COLOR SAMPLES TO OWNER FOR
3. THE CONTRACTOR SHALL INDEMNIFY AND HOLD CARL J. COLSON -ARCHITECT FOR ALL WINDOW SIZES AND EGRESS REQUIREMENTS. APPROVAL.
PLLC AND THEIR CONSULTANTS HARMLESS FOR INJURY OR DEATH TO PERSONS 3. ALL NEW BEDROOMS (AND AREAS ADJACENT TO BEDROOM ENTRY) SHALL HAVE 3. PREPARE FLOOR PER FLOORING AND CARPET MANUFACTURERS RECOMMENDATIONS TO PROVIDE
OR FOR DAMAGE TO PROPERTY CAUSED BY THE CONTRACTOR, HIS AGENTS, SMOKE DETECTORS (W/ BATTERY BACKUP) HARDWIRED INTO THE ELECTRICAL LEVEL AREA FOR FLOORING INSTALLATION AND LEVEL FLOORING TRANSITIONS.
Carl J. COISOri -Architect
EMPLOYEES OR SUBCONTRACTORS. SYSTEM. 4. ALL FLOORING MATERIALS TO BE LIGHT WEIGHT. CERAMIC TILE SHALL BE THIN -SET TYPE.
4. EACH CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGE TO ADJACENT 4. OCCUPANCY SEPARATION WALLS ARE REQUIRED IN THIS PROJECT BETWEEN THE
PLLC
WORK AND SHALL REPAIR SAID DAMAGE AT HIS OWN EXPENSE. LIVING SPACE AND ATTACHED GARAGE AT EACH RESIDENTIAL UNIT. CASEWORK &MILLWORK
5. ANY WORK INSTALLED IN CONFLICT WITH THESE DRAWINGS SHALL BE 5. NO AREA SEPARATION WALLS ARE REQUIRED IN THIS PROJECT. CONTRACTOR NOTE: THE FLOOR PLANS SHOW KITCHEN AND BATH CABINETS IN FLOOR PLANS ONLY.
23623 2Oth AVe. W
CORRECTED BY THE SUBCONTRACTOR AT NO EXPENSE TO THE OWNER OR CARL 6. CONSTRUCTION TYPE: TYPE V-B. CONTRACTOR SHALL COORDINATE SELECTION OF CABINET MANUFACTURER AND TYPE WITH HOME
J. COLSON -ARCHITECT PLLC. 7. ADDRESSES SHALL BE POSTED ON THE BUILDING AS REQUIRED BY THE 2015 OWNER.
Bothell, WA 98021
6. ONLY APPROVED "PERMIT SET" MARKED DRAWINGS INCORPORATING ALL INTERNATIONAL RESIDENTIAL BUILDING CODE AND APPLICABLE FIRE SAFETY CODE. 1. ALL MILLWORK (WOODWORK AND CABINETRY) SPECIFIED ON THESE DRAWINGS SHALL BE
ADDENDA AND DIMENSIONAL CLARIFICATIONS SHALL BE USED DURING THE 8. ALL REQUIRED FIRE RATED DOORS SHALL BEAR A LABEL FROM A RECOGNIZED FURNISHED AND INSTALLED BY THE MILLWORK CONTRACTOR UNLESS NOTED OTHERWISE.
425-806-3%O3
EXECUTION OF THE WORK. AGENCY. 2. THE MILLWORK CONTRACTOR SHALL BE RESPONSIBLE FOR APPLYING FINISHES FOR ALL
WWWCaT1COlSOTlATChlteCt.COm
7. ALL PRODUCTS AND MATERIALS SPECIFIED IN THE DRAWINGS (W/ EXCEPTION 9. THIS RESIDENCE IS NOT REQUIRED TO HAVE A FIRE SPRINKLER SYSTEM MILLWORK IN HIS SHOP. DO NOT APPLY FINISH COATS IN FIELD.
OF SPECIFIC FINISH COLORS AND FLOORING) ARE INTENDED TO BE ON AN "OR 3. ALL MATERIALS AND WORKMANSHIP MUST BE EQUAL IN ALL RESPECTS TO THE STANDARDS SET
Commercial &Residential
EQUAL" BASIS. ANY PROPOSED SUBSTITUTIONS MUST BE SUBMITTED TO CARL J. MOISTURE CONTROL FORTH IN THE ARCHITECTURAL WOODWORKING INSTITUTE (A.W.I.). MOST CURRENT EDITION
COLSON -ARCHITECT PLLC OR OWNER IN WRITING FOR APPROVAL WITHOUT PUBLISHED BY THE A.W.I. AND THE STANDARDS SET BY THE OWNER /CONTRACTOR.
ATChlteCtUre
DELAY OF SCHEDULE. 1. ALL INTERIOR FACE OF EXTERIOR WALLS AND CEILINGS SHALL BE PAINTED WITH A 4. PLYWOOD SHALL PER THE GRADE AND TRADEMARK IDENTIFICATION OF THE AMERICAN PLYWOOD
8. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATIONS AND P.V.A. PAINT TO MINIMIZE MOISTURE PENETRATION OF EXTERIOR WALLS OR CEILING ASSOCIATION (APA).
COORDINATION OF SUBCONTRACTORS' WORK TO SECURE COMPLIANCE WITH INSULATION SPACE, 5. PARTICLEBOARD BACKING SHALL BE PERMITTED IN AREAS OF THE CASEWORK THAT ARE NOT
Evans Residence
DRAWINGS AND SPECIFICATIONS. THIS INCLUDES THE ACCURATE LOCATION OF 2. WALLS: INSERT STAPLED BATTS WITH A PERM RATING EQUAL TO OR LESS THAN 1.0 VISIBLE.
STRUCTURAL MEMBERS AND OPENINGS FOR MECHANICAL, ELECTRICAL, STAIRS, MAY BE INSTALLED IF STAPLES ARE PLACED MAXIMUM 8" O.C. AND GAPS BETWEEN 6. PROVIDE CUT-OUTS IN MILLWORK AS REQUIRED FOR ALL ELECTRICAL ITEMS. VERIFY ALL
Proje t Addre s
AND MISCELLANEOUS EQUIPMENT. THE FACING AND FRAMING DO NOT EXCEED 1/16". REQUIREMENTS PRIOR TO FABRICATION.
20018 83rd Ave. W.,
9. AT COMPLETION OF THE WORK, REMOVE ALL DEBRIS FROM THE SITE, LEAVING 3. THE FOLLOWING OPENINGS IN THE BUILDING ENVELOPE SHALL BE SEALED, 7. FIT AND SECURE CABINET HARDWARE PER MANUFACTURER'S PRINTED INSTRUCTIONS. EXERCISE
THE BUILDING CLEAN. ALL WINDOWS AND GLASS SHALL BE WASHED, ALL CAULKED, GASKETED, OR WEATHERSTRIPPED TO LIMIT AIR LEAKAGE: EXTERIOR CAUTION NOT TO INJURE OR MAR SURFACES. REPAIR ANY AND ALL DAMAGED SURFACES TO LIKE-
EdmOndS WA 98026
CARPETS SHALL BE CLEANED (AS NECESSARY) AND VACUUMED. ALL FLOORS JOINTS AROUND WINDOWS AND DOOR FRAMES, OPENINGS BETWEEN WALLS AND NEW CONDITION.
�
SHALL BE CLEANED AND SWEPT. CONTRACTOR SHALL REPAIR OR REPLACE ANY FOUNDATION, BETWEEN WALLS AND ROOF AND BETWEEN WALL PANELS: OPENINGS 8. ALL MILLWORK ELECTRICAL MATERIAL, WORKMANSHIP, AND INSTALLATIONS SHALL BE IN
DAMAGED ITEMS PRIOR TO FINAL INSPECTION. AT PENETRATIONS OF UTILITY SERVICES THROUGH WALLS, FLOORS, AND ROOF. CONFORMANCE WITH APPLICABLE LOCAL, STATE, AND NATIONAL ORDINANCES AND CODES. ALL
New SFR at 20018 83rdAve. W (Lot 1 of
4. ALL EXTERIOR WINDOWS SHALL BE DESIGNED TO LIMIT AIR LEAKAGE INTO OR FROM MATERIAL AND FIXTURES TO BE U.L. APPROVED.
PLN20180037)
BUILDING CODE NOTES THE BUILDING ENVELOPE. MANUFACTURED WINDOWS SHALL HAVE AIR INFILTRATION 9. THE GENERAL CONTRACTOR SHALL FURNISH ALL NECESSARY WOOD BLOCKING FOR A COMPLETE
RATES NO GREATER THAN 0.5 CFM. AND SECURE INSTALLATION.
City of Edmonds Permit #: BLD2020-0250
1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SAFETY IN THE AREA OF WORK
�j\
IN ACCORDANCE WITH THE APPLICABLE SAFETY CODES. ELECTRICAL /MECHANICAL /PLUMBING WATERPROOFING CONSTRUCTION NOTES
Project Client
2. THE CONTRACTOR IS RESPONSIBLE FOR ALL NECESSARY PERMITS AND FEES. THIS ENTIRE SET OF ARCHITECTURAL DRAWINGS IS PREPARED AS A PERMIT SET OF DRAWINGS
Marne &Simon Evans
3. ALL ELECTRICAL AND MECHANICAL WORK SHALL BE DESIGN -BUILD AND SHALL 1. HEATING WILL BE PROVIDED BY A GAS FURNACE TO BE LOCATED IN INSULATED ONLY FOR THE OWNER AND BUILDER FOR THIS PROJECT ONLY. ALL DETAILS AND DRAWINGS SHOWN
20020 83rd Ave. W.
BE UNDER SEPARATE PERMITS TO BE OBTAINED BY THE CONTRACTOR. MECHANICAL ROOM. HOT WATER WILL BE PROVIDED BY A GAS FIRED WATER HEATER ARE FOR PERMIT PURPOSES ONLY AND DO NOT CONSTITUTE THE FULL SET OF DETAILS REQUIRED
4. ALL WORK SHALL CONFORM TO THE APPLICABLE BUILDING CODES AND LOCATED IN MECHANICAL ROOM. GENERAL CONTRACTOR AND MECHANICAL TO CONSTRUCT THIS PROJECT. THE BUILDER SHALL BE RESPONSIBLE FOR DEVELOPING
Edmonds, WA 98026
ORDINANCES. IN CASE OF ANY CONFLICT WHERE THE METHODS OR STANDARDS SUBCONTRACTOR SHALL REVIEW FURNACE AND WATER HEATER LOCATION AND CONSTRUCTION DETAILS NECESSARY TO CONSTRUCT A WEATHERTIGHT, DURABLE BUILDING.
OF INSTALLATION OF THE MATERIALS SPECIFIED DO NOT EQUAL OR EXCEED THE DETERMINE ROUTE FOR EXHAUST FLUE PRIOR TO FRAMING OF BUILDING. ALL FLASHING, WEATHERPROOFING, ROOFING, AND WATERPROOFING DETAILS AND CONSTRUCTION
Sheet Title
REQUIREMENTS OF THE LAWS OR ORDINANCES, THE LAWS OR ORDINANCES MECHANICAL SUBCONTRACTOR TO PROVIDE HEATING LOAD CALCULATIONS TO OF THESE DETAIL ASSEMBLIES ARE THE FULL AND COMPLETE RESPONSIBILITY OF THE BUILDER, AND
SHALL GOVERN. NOTIFY THE ARCHITECT OF ANY AND ALL CONFLICTS IN WRITING. APPLICABLE BUILDING DEPARTMENT FOR APPROVAL AND PERMIT PRIOR TO THESE DETAILS SHALL BE CONSTRUCTED PER MANUFACTURER REQUIREMENTS, BUILDING CODE
General Notes
5. THE CONTRACTOR SHALL PROVIDE TEMPORARY FACILITIES AS REQUIRED BY CONSTRUCTION. GENERAL CONTRACTOR AND MECHANICAL SUBCONTRACTOR SHALL REQUIREMENTS, AND ACCEPTED INDUSTRY STANDARDS FOR PERFORMANCE.
CODE. REVIEW ALL DRAWINGS PRIOR TO CONSTRUCTION TO BEST DETERMINE ROUTING OF PER WASHINGTON STATE LAW, THE TOWNHOUSE UNITS REQUIRE THE DESIGN AND INSPECTION
ALL NEW DUCTWORK AND VENT LOCATIONS. SERVICES OF A BUILDING ENCLOSURE DESIGNER TO DESIGN ALL FLASHING AND WATERPROOFING
DIMENSIONS AND FRAMING NOTES 2. ALL PLUMBING FIXTURES SHALL COMPLY WITH FLOW RATES AS REQUIRED BY THE DETAILS AND INSPECTION OF THESE ITEMS. CONTRACTOR SHALL COORDINATE ALL TOWNHOUSE
APPLICABLE WASHINGTON STATE PLUMBING CODE. THE REDUCED FLOW FIXTURE BUILDING ENCLOSURE DETAILS WITH BUILDING ENCLOSURE DESIGN FIRM.
1. ALL DIMENSIONS SHOWN ON THE DRAWINGS RELATIVE TO EXISTING RATES ESTABLISHED BY THE WASHINGTON STATE ENERGY CODE SHALL NOT APPLY,
CONDITIONS ARE GIVEN AS THE BEST PRESENT KNOWLEDGE, BUT WITHOUT UNLESS NOTED AS AN ENERGY CREDIT OPTION ON SHEET A-6.1 THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING A WEATHERTIGHT BUILDING
GUARANTEE OF ACCURACY. THE CONTRACTOR SHALL FIELD VERIFY EXISTING 3. PROVIDE LAUNDRY ROOM WITH MECHANICAL VENTILATING SYSTEMS AS SHOWN (5 INCLUDING ALL NECESSARY SEALANT AND FLASHINGS IN ACCORDANCE WITH INDUSTRY
CONDITIONS AND DIMENSIONS AND SHALL NOTIFY CARL J. COLSON -ARCHITECT AIR CHANGES PER HOUR PER WASHINGTON STATE ENERGY CODE). STANDARDS, WHETHER DETAILED SPECIFICALLY IN THESE DRAWINGS OR NOT.
%543
PLLC OF ANY DISCREPANCIES OR CONDITIONS ADVERSELY AFFECTING THE 4. ALL SOLDER USED IN PLUMBING CONNECTIONS, SHALL BE LEAD FREE AS DEFINED
REGISTERE
DESIGN PRIOR TO PROCEEDING WITH THE WORK. BY WAC STANDARDS 51-16-060. 1. EXTERIOR DOORS, WINDOWS, VENTS, CORRIDOR OPENINGS:
ARCHITECT
2. DO NOT SCALE THE DRAWINGS. CONTRACTOR MUST VERIFY ALL DIMENSIONS 5. ALL ELECTRICAL TRIM TO BE COLOR SELECTED BY OWNER. THE CONTRACTOR SHALL SEAL AROUND ALL EXTERIOR WINDOWS, DOORS, VENTS AND OTHER SUCH
AND FIELD CONDITIONS PRIOR TO COMMENCING THE WORK. THE CONTRACTOR 6. CLOTHES DRYER MOISTURE EXHAUST VENTS SHALL COMPLY WITH PENETRATIONS WITH A CONTINUOUS BEAD OF CAULKING TO PROVIDE FOR AWEATHER-TIGHT
G�'"c ,
SHALL USE DIMENSIONS SHOWN ON THE DRAWINGS AND ACTUAL FIELD MANUFACTURER'S REQUIREMENTS FOR MAXIMUM HORIZONTAL AND VERTICAL STRUCTURE. IN ADDITION, ALL EXTERIOR OPENINGS (WINDOWS, DOORS, VENTS, CORRIDOR
CARL J. COLSON
MEASUREMENTS. NOTIFY CARL J. COLSON -ARCHITECT PLLC IF ANY LENGTHS AND AS PER UNIFORM MECHANICAL CODE. OPENINGS) SHALL BE FLASHED WITH A FLASHING MEMBRANE AS SHOWN ON THE WINDOW DETAIL
SATE OF WASHINGTO
DISCREPANCIES ARE FOUND. 7. ALL INTERIOR PLUMBING WALLS SHALL BE INSULATED FOR SOUND CONTROL. SHEET. USE METAL HEAD FLASHING ABOVE ALL EXTERIOR DOORS AND WINDOWS. FURNISH AND
3. ALL INTERIOR FRAMED WALL DIMENSIONS ARE SHOWN TO FACE OF STUD, INSTALL FLASHINGS IN ACCORDANCE WITH SMACNA STANDARDS.
UNLESS NOTED OTHERWISE. DIMENSIONS TO THE EXTERIOR SIDE OF WOOD MATERIALS 2. SEE SHEET A-4.1 CONSTRUCTION ASSEMBLY NOTES FOR INFORMATION ON BASEMENT WALL
ISSUED FOR PERMIT 1-21-2020
FRAMED WALLS ARE TO THE FACE OF STUD. SEE NOTE SECTION "MOLD CONTROL" FOR INFORMATION ON GYPSUM BOARD WATERPROOFING.
4. OFFSET STUDS WHERE REQUIRED TO MAKE STRAIGHT AND CONTINUOUS WALL PRODUCTS.
Document Set Type:
PLANES, ESPECIALLY AT FLOOR OPENINGS. ALL PARTITIONS AND WALLS SHALL 1. SHOWER /TUB UNITS SHALL BE AS SPECIFIED ON DRAWINGS. COORDINATE THIS PRESSURE TREATED WOOD /STRUCTURAL FASTENERS
EXTEND FULL HEIGHT TO STRUCTURE ABOVE, UNLESS NOTED OTHERWISE. ITEM PRIOR TO PROVIDING BID PRICE. EFFECTIVE DEC. 31, 2003, THE PRESSURE TREATED WOOD INDUSTRY VOLUNTARILY TRANSITIONED
5. THE CONTRACTOR SHALL VERIFY SIZES AND LOCATIONS OF ALL OPENINGS FOR 2. ALL GYPSUM WALLBOARD IN BATHROOMS SHALL BE WATER RESISTANT. FROM CHROMATED COPPER ARSENATE (CCA-C) USED IN RESIDENTIAL CONSTRUCTION TO
Revision Schedule
MECHANICAL AND ELECTRICAL EQUIPMENT WITH THE RESPECTIVE 3. ALL WEATHER EXPOSED SURFACES SHALL HAVE AWEATHER-RESISTANT BARRIER ALTERNATIVE TREATMENTS. ANY PRESSURE TREATED WOOD SPECIFIED FOR THIS PROJECT SHALL
Rev.
SUBCONTRACTORS PRIOR TO CONSTRUCTION. (AS INDICATED ON SHEET A-4.1) INSTALLED BEHIND EXTERIOR SIDING TO PROTECT NOT CONTAIN CCA-C IN THE PRESERVATIVE PROCESS.
"TESTING
# Date Description
6. THE CONTRACTOR SHALL VERIFY ALL ROUGH -IN DIMENSIONS FOR EQUIPMENT, INTERIOR WALL MATERIALS. SEE SECTION DRAWINGS FOR ADDITIONAL INFORMATION. ACCORDING TO SIMPSON STRONGTIES WEBSITE, HAS SHOWN THAT CERTAIN
DOORS, AND WINDOWS. UCTIO REPLACEMENT ALTERNATIVE TREATMENTS ARE GENERALLY MORE CORROSIVE THAN CCA-C". AS A
1
6-15-2020
Add Window/ Permit Revisions
7. ALL DOORS NOT LOCATED BY DIMENSIONS ON PLANS, INTERIOR ELEVATIONS, 4. WOOD SUPPORTS IN CONTACT WITH SOIL OR MASONRY OR LOCATED NEARER THAN RESULT OF THESE ALTERNATIVE METHODS OF TREATMENT, THE NON CCA-C TREATED WOOD IS
OR DETAILS SHALL BE 5" FROM FACE OF STUD TO EDGE OF DOOR OPENING. 6" TO SOIL SHALL BE PRESSURE TREATED WOOD. SEE NOTES FOR PRESSURE MORE CORROSIVE TO METAL HANGERS AND FASTENERS. REFER TO SIMPSON STRUCTURAL
8. FINISH FLOOR ELEVATION REFERS TO TOP OF CONCRETE SLAB OR TOP OF TREATED WOOD AND FASTENERS REQUIREMENTS ON THIS PAGE. HANGERS WEBSITE FOR TECHNICAL BULLETIN. (wwwSTRONGTIE.COM (SIMPSON'S WEBSITE), GO TO
PLYWOOD FLOOR DECK. 5. GYPSUM WALLBOARD SHALL NOT BE INSTALLED UNTIL WEATHER PROTECTION IS "CORROSION INFORMATION" THEN "PRESSURE TREATED WOOD TECH BULLETIN".) . REFER TO
9. REPETITIVE FEATURES ARE OFTEN DRAWN ONLY ONCE AND SHALL BE INSTALLED. SIMPSON'S WEBPAGE "wwwSTRONGTIE.COM/PRODUCTUSE/SELECTION-GUIDE.HTML" FOR PRODUCT
COMPLETELY PROVIDED AS IF DRAWN IN FULL. CROSS REFERENCES SHOWN ON 6. WHEN INSTALLED DIRECTLY ON FRAMING, ALL EDGES AND ENDS OF GYPSUM USE SELECTION GUIDE.
DRAWINGS DO NOT NECESSARILY INDICATE ALL LIKE CONDITIONS AND DO NOT WALLBOARD SHALL OCCUR ON THE FRAMING MEMBERS, EXCEPT THOSE EDGES REFER TO SIMPSONS WEBSITE FOR REQUIREMENTS FOR NAILS, BOLTS, AND HANGERS USED WITH
DRAWING USE NOTIFICATION
LIMIT APPLICATION OF ANY DRAWING OR DETAIL. THEY MAY APPLY TO OTHER WHICH ARE PERPENDICULAR TO THE FRAMING. PRESSURE TREATED WOOD. STANDARD HOT DIPPED GALVANIZED EASTERNERS, BOLTS, AND NAILS
SAME OR SIMILAR CONDITIONS NOT REFERENCED. 7. ALL FLOORING MATERIAL (CARPET, TILE, VINYL), WALL TILE, AND PAINT FINISHES MAY NOT ACCEPTABLE WITH THE NEW TYPES OF PRESSURE TREATED WOODS (ACCORDING TO
This set of drawings is being issuedasaProgressorPermitsetofDrawings
10. KITCHEN LAYOUT IS SCHEMATIC ONLY. COORDINATE KITCHEN LAYOUT WITH SHALL BE SELECTED BY HOME OWNER. CONTRACTOR SHALL COORDINATE SELECTION SIMPSON'S WEBSITE TECHNICAL PUBLICATIONS.).
and is subject to change and adding of additional information and
OWNER. CABINET STYLES AND MATERIALS SHALL BE SELECTED BY OWNER / OF THESE ITEMS WITH HOME OWNER. BUILDER /DEVELOPER SHALL BE RESPONSIBLE FOR VERIFYING WHICH FASTENERS ARE
drawings as required by review of the Building Department in the
CONTRACTOR. ACCEPTABLE FOR USE AND SHALL TAKE LIABILITY FOR PERFORMANCE OF FASTENERS OR
jurisdiction where this project is located.
11. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL WALL HAZARDS (GUARDRAILS &SAFETY GLAZING CONNECTORS SELECTED AND USED ON THIS PROJECT.
DO NOT USETH1sDRAwINGEORcoNSTRUCTIONUNLEssTHIs
BLOCKING AND BRACING REQUIRED FOR WALL AND CEILING MOUNTED ITEMS. ANY REFERENCES ON STRUCTURAL DRAWINGS FOR THIS PROJECT TO PRESSURE TREATED WOOD
DRAwINGHASABUILDINGDEPARTMENT°APPRoyED°sTAMP
APPLIED BY THE BUILDING DEPARTMENT UPON COMPLETION OF
12. ALL NEW CONSTRUCTION SHALL BE STABILIZED AGAINST LATERAL MOVEMENT 1. GUARDRAILS SHALL BE NO LESS THAN 36 INCHES IN HEIGHT. INTERMEDIATE SHALL DEFER TO THE REQUIREMENTS LISTED ABOVE.
THE PERMITREVIEwPRocEss.
IN ACCORDANCE WITH THE REQUIREMENTS OF THE 2009 SEATTLE RESIDENTIAL RAILINGS ARE REQUIRED AND ARE TO BE ARRANGED SO THAT A 4-INCH SPHERE
Do not use this drawing for Bidding or Estimating Purposes unless
BUILDING CODE AND STATE OF WASHINGTON BUILDING CODE AND ALL CANNOT PASS THROUGH. MOLD CONTROL
authorized by Client. During Construction Phase, the Clients General
APPLICABLE SEISMIC REQUIREMENTS. 2. SAFETY GLAZING IS REQUIRED IN ALL DOORS, RAILINGS, AND TUB OR SHOWER PROPER STORAGE AND HANDLING OF BUILDING PRODUCTS HELPS PREVENT MOLD
Contractor(Builder)orDeveloper shall be responsible for ensuring that all
ENCLOSURES. ANY GLAZING WITHIN A DOOR OPENING AND WITHIN 60 INCHES OF THE KEEP STOCKS OF LUMBER, PLYWOOD, ORIENTED -STRAND BOARD (OSB), DRYWALL, AND OTHER
Construction Personnel of the General Contractor and all subcontractors
ARCHITECTURAL SITE NOTES FLOOR SHALL BE SAFETY GLAZING. FIXED GLAZING GREATER THAN 9 SQUARE FEET IN POROUS MATERIALS IN A DRY, COVERED STORAGE AREA. IF THE STOCKPILES ARE OUT IN THE OPEN,
are Supplied with allappYOUCG�andmostcurrentdocuments.
AREA AND WITHIN 18 INCHES OF THE FLOOR IS TO BE SAFETY GLAZING. REFER TO AND IT LOOKS LIKE IT MIGHT RAIN, COVER THE MATERIALS WITH A GOOD TARP, ANCHORED DOWN
ARCHITECTURAL COPYRIGHT
1. REFER TO SURVEY IF SURVEY WAS COMPLETED FOR THIS PROJECT AND/OR 2009 INTERNATIONAL RESIDENTIAL BUILDING CODE FOR ADDITIONAL AREAS OF SO THAT THE WIND DOES NOT BLOW IT OFF. WHEN THE MATERIALS ARE NEEDED, REMOVE THEM
( )
This sheet of drawings may not be reproduced in any form without prior
CIVIL ENGINEERING DRAWINGS FOR ADDITIONAL NOTES AND INFORMATION FOR SAFETY GLAZING. FROM BENEATH THE COVER WITHOUT ALLOWING THE REMAINDER TO GET WET OR DAMP.BEFORE
approval of Carl).Colson-Architect PLLC.
EXISTING CONDITIONS. INSTALLING THE MATERIALS, INSPECT CAREFULLY FOR WATER DAMAGE, STAINING, WARPING, OR
These document, the ideas, and designs incorporated herein as an
2. VERIFY ALL UNDERGROUND UTILITIES AND SITE GRADES PRIOR TO INDOOR AIR QUALITY NOTES INITIAL SIGNS OF MOLD GROWTH. SUCH SIGNS MIGHT BE VISIBLE PATCHES OF MOLD, OR MUSTY
instrument of service shall remain the property of Carl].Colson-Architect
CONSTRUCTION. ODORS ASSOCIATED WITH MOLD OR MILDEW. DISCARD ANY SUCH MATERIALS IMMEDIATELY.INSTALL
PLLC and are solely for the use on this project only. These files, drawings,
3. COORDINATE PROPERTY CORNERS WITH SURVEYOR. 1. SOURCE SPECIFIC VENTILATION: SOURCE SPECIFIC EXHAUST VENTILATION SHALL A ROOF OR COVER THE NEW CONSTRUCTION AS SOON AS PRACTICAL.
ideas, or designs may not betramsmittedelectronicallywithoutexpress
permission of Architect. They are not be used by the client or any other
4. CONTRACTOR SHALL VISIT THE SITE AND APPRAISE HIMSELF/ HERSELF OF THE BE REQUIRED IN EACH KITCHEN, BATHROOM, WATER CLOSET, LAUNDRY ROOM, AND
party or entity on other projects, in whole or part, or as an extension to this
EXISTING CONDITIONS AND SEQUENCE PRIOR TO ANY CLEARING OR DEMOLITION OTHER ROOMS WHERE EXCESS WATER VAPOR OR COOKING ODOR IS PRODUCED. DRYING WOOD CONSTRUCTION PRIOR TO INSULATION OR DRYWALL INSTALLATION
project except by agreement in writing with appropriate financial
WORK. BATHROOM EXHAUST FANS AT 75 CFM, KITCHEN EXHAUST FANS AT 100 CFM. WHEN THE BUILDING FRAME IS COMPLET AND EXTERIOR SIDING IS INSTALLED, CONTRACTOR SHALL
compenSationtoCarlJ.Colson-Architect PLLC.
Copyright CarlJ.Colson-PLL,C,2o19. All cO
5. VERIFY ALL TOP OF SLAB ELEVATIONS AT ALL BUILDING AND PROPERTY LINES. LAUNDRY EXHAUST FANS AT 100 CFM. USE APIN-TYPE MOISTURE METER TO VERIFY MOISTURE CONTENT IN WOOD FRAMING, FLOOR
rights reserved.
Project Number
6. CONTRACTOR SHALL VERIFY SIZES AND LOCATIONS OF ALL MECHANICAL AND 2. A WHOLE HOUSE FAN W/TIMER (100 CFM MIN., 1.5 SOMES) WILL BE LOCATED IN THE SHEATHING, WALL SHEATHING, AND ROOF SHEATHING.
ELECTRICAL PADS AND BASE, ALONG WITH POWER, WATER AND / OR DRAINAGE LAUNDRY ROOM AT THE FIRST FLOOR. MOISTURE CONTENT OF ALL WOOD MEMBERS AND SHEATHING SHALL BE 15% OR LESS. IF THE
INSTALLATIONS BEFORE PROCEEDING WITH THE WORK. 3. VENTILATION DUCTS: ALL DUCTS SHALL TERMINATE OUTSIDE THE BUILDING. MOISTURE CONTENT IS HIGHER, CONTRACTOR SHALL USE A COMBINATION OF HIGH VOLUME FANS
..
SheetlssueDate
AND DEHUMIDIFIERS TO THOROUGHLY DRY THE WOOD FRAMING AND SHEATHING PRIOR TO ANY
04/17/13
•
INSTALLATION OF INSULATION OR DRYWALL. THIS SHOULD BE DONE TO HELP MINIMIZE Alf ESU B
Drawn By
MOISTURE DAMAGE TO INTERIOR OF WOOD FRAMING SURFACES OR SHEATHING.
Author
General Notes
Jun 15 2020
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
Sheet Plot Dat�/14/2020 7:33:25 PM
Scale
12" = 1 �-0"
www.CarlColsonArchitect.com
��' r '�a�i�' �r
.�1� , I!� �a�
\���� � �
� +i
�I iii����ii�'
,� �` 1� I� �'® � III
�� � 7
__-- -
__ �
� — �� �� � � � ii � � i� I���II
G � � � �C � i � �� � i ��'
��- �
-_11 �Il��ll � ,
nnJl
■ice ,
= ,�'
_ �I��
■� �Pllf
:,�.�,,:
HEATED LIVING SPACE
1' - 3"
19' -1 1 /4"
�
RIPPED PRESSURE TREATED ANCHOR PLATE
10' - 3"
8'-101/4"
i
TO EXTEND FULL WIDTH OF FOUNDATION
�
WALL. BRUSH PRESERVATIVE SEALANT ON
SIDES AND ENDS OF CUT ANCHOR PLATE
NOTE: THIS RAISED FOUNDATION WALL OCCURS
(�;
�yLJ/
�r,�
- - - �LJf
i
ONLY AT PORCH AREAS. SEE ARCHITECTURAL
FOUNDATION PLAN ON SHEET A-2.1 FOR
-
r \----------------------- J
'-
y LJ / �
���
I �
�
LOCATIONS OF RAISED FOUNDATION WALLS
LEVEL 1 : ELEV. 0'- 0"
=
�
i
�
;
Carl J. Colson -Architect
23'-5"
I
�
�
(SEE SITE PLAN FOR
�
I
r; l
�
ACTUAL ELEVATION)
12 0 11 5
14 1
i
i M
i � CRAWL SPACE VENTS (w11NSECT
PLLC
� �
�
TOP OF CONC. WALL :
� r�� _ _ _ _
� L J /
i
1' -i 3" 10' - 3"
12' - 7"
i SCREENS) IN CONCRETE FOUNDATION
6' - 31/4" i WALLS
23623 20th Ave. W
N
/ ELEV. (-) 0'-2 ,/4"
. ,
,
, VENTS SHALL BE 8" X 16". VENTS TO
N it I
°
I _
o
�
i BE INSTALLED IN CONCRETE
Bothell WA 98021
i _a
i FOUNDATION WALL AND SHALL HAVE
i
, I
"°
P.T. LEDGER BEAM °I -� : _ a - ;=a
J
_
° "° - -,
VENT
I
� GALVANIZED STEEL VENT WELLS
� ��� INSTALLED IN FINISH GRADE /
425-806-3703
ATTACHED TO I - � - °�_ a �° `:ri• �.-- I
I
INSTALL WEATHER RESISTIVE BARRIER
-
z
-
o � LJ
TOPSOIL.
FOUNDATION WALL - � '. I
BETWEEN JOIST HANGER AND �
� VENT
r T i SEE CRAWLSPACE VENT CALC'S ON
WWWCarlColsonArchitect.com
PER STRUCTURAL - _ °° - -° I
-
DRAWINGS "�_ ° .,
" �- °
FOUNDATION WALL PRIOR TO HANGING
Unexcavated
w
o
i THIS SHEET
i
a a a _
I °� a � - a - .
I
JOISTS
z
o
Commercial &Residential
I ° _ "° � :"
° °
BUILDING
(Garage Slab Above)
�
�
I i o BUILDING
SEE FOUNDATION I 4^ _,�4<�-ao- ;a I
SECTION
FLOORJOISTS@THISAREAARE
;
i SECTION
Architecture
PLANS FOR SHADED I `_ •. --
JOIST HANGERS HUNG FROM
1
GRAY SHADED FOUNDATION WALLS HAVE TOP OF
TO BE ATTACHED TO SILL PLATE w/
o
�
1
a
WALL LOCATIONS FOR -� - -
ANCHOR PLATE PER STRUCT. DWGS.
—
WALL ELEVATION 2-114" BELOW LEVEL 1 FLOOR
SIDE MOUNTED JOIST HANGERS
o
_ — � i—
AREAS OF RAISED d _ _ � a - " -
FOUNDATION WALLS � I �' . - a -a �°�
CONC. FOUNDATION WALL PER
A-4.1
ELEVATION (TYP)
(TYP). COORDINATE w/
STRUCTURAL DRAWINGS
o
o i A-4.1
r i
��1
a � e � d e � e
� LOCATION OF PORCH COLUMNS.
iiiL1JJ
I � _
I . ° � a °" -' - °
" ° a
STRUCTURAL DRAWINGS
CRAWL SPACE
STEP BOTTOM OF THIS WALL TO ALLOW FOR
CRAWL SPACE CLEARANCE BELOW FURNACE
DROPPED BEAM TO SUPPORT
FLOOR JOISTS ABOVE. SEE
i
I i SEE LEVEL 1 FLOOR PLAN FOR
; LOCATION & DIMENSIONS OF
Project Address
aQ a
_
DUCTS IN CRAWL SPACE. COORDINATE THIS ITEM
W/ H.V.A.C. &FOUNDATION SUBCONTRACTOR
STRUCTURAL DRAWINGS
i COLUMNS.
i SEE STRUCTURAL DRAWINGS
20018 83rd Ave. W.,
I FOR SIZE OF SUPPORT POST &
ALLOW OPENING IN FLOOR FRAMING FOR
,-,.� CONCRETE FOOTING (TYP)
Edmonds, WA 98026
DUCTWORK FROM FURNACE ABOVE. COORDINATE
SUPPORT POST, FOOTINGS,
VENT
t
6' - 31/4" � L J 2 3/4"
W/ H.V.A.C. &FRAMING SUBCONTRACTORS
FLOOR FRAMING
� FOUNDATION WALL DROPS @THIS AREA
i
SEE STRUCTURAL DRAWINGS FOR
o
�� i N
6 - 6 '
New SFR at 20018 83rd Ave. W (Lot 1 of
2030 SOLID DOOR (WI RIGID INSULATION ADHERED
LOCATIONS OF ALL SUPPORT
w
HEATED LIVING SPACE
TO BACK) FOR ACCESS TO CRAWL SPACE. DOOR
POSTS &FOOTINGS FOR FLOOR
°�
PLN20180037)
HEAD HEIGHT TO ALLOW FOR CLEARANCE OF
FRAMING BEAMS @CRAWL
SPACE. SEE STRUCTURAL
�
N
VENT
City of Edmonds Permit #: BLD2020-0250
�
i
TYPICAL EXTERIOR WALL CONSTRUCTION. SEE
SHEET A-4.1 FOR NOTES
HEATING SUPPLY DUCTS IN THIS AREA.
EXCAVATE CRAWL SPACE @THIS CORNER TO
DRAWINGS FOR SIZE OF SUPPORT
;
�,
FOUNDATION WALL T
i
ALLOW FOR CODE REQUIRED CLEARANCE BELOW
POST &CONCRETE FOOTING TYP
( )
�
STEP 2'-9"VERTICAL
LANDSCAPE BLOCK RETAINING
1
Project Client
�
SEE SHEET A-4.1 FOR FLOOR ASSEMBLY
� o
�,
"
HVAC DUCTS
_ _ Crawl Space
o
�
FOUNDATION WALL �, �
� � WALLS (TYP). SEE CIVIL
STEP 3 0 VERTICAL � O°
Marne & S1mon Evans
INFORMATION
�
5l8" TYPE X GYP. BD. @WALLS &CEILING OF
r � 350 S.F.
ENGINEERING GRADING PLAN.
�
LEVEL 1 : ELEV. 0'- 0"
STORAGE BENEATH STAIRS
� FURNACE �
FOUNDATION WALL _ COORDINATE LOCATION OF
20020 83rd Ave. W.
( SEE SITE PLAN FOR
15' -1" r___, g� _ 4��
� ABOVE �
15' - 2"
STEP 1'-0"VERTICAL RETAINING WALLS w/
FOUNDATION WALL STEPS
Edmonds, WA 98026
ACTUAL ELEVATION) �
� LIJ i LOWER TOP OF FOUN .WALL
5' - 5" �
L J
_
1 -0
11 3/4" �- -J T-41/4"
— —
_ - - - -
d ,
�
- - - - - "'
Sheet Title
=
-
° N r
16'-2"
�
T
Basement Plan
'
°
LOWER TOP OF CONC.
_
T
`"
-
FOUNDATION WALL
i
i
�
N
FOUND. WALL @THIS
AREA SO THAT GARAGE 1/2 - 8
5 5
15' - 71/2"
STEPS 8" EACH r
r
SLAB SITS ON TOP OF N i
2030
WALL @THIS AREA � Up 7 T @ 1Q°
TV / Rec Room O
3'-101/2" M 5' � 10"
Storage
i
J 1"GAP BETWEEN
�
4" CONCRETE SLAB
INSULATED 2 x 6 J
= � FOUND. WALL &BACK 1��
2668 `�'
ON GRADE w/ R-10
FURRING WALL (wl � �
- °
T z OF STUD @FURRING UP N
'� N
RIGID INSULATION
WOOD CAP & � M N
a °°- �- a- ° -"_ �
" a
� TOP OF CONC. WALL :ELEV. (-) 1'-2 1 /8"
o =o WALLS (TYP) M
�
o
UP �
BELOW BASEMENT
TRIM) ADJACENT � T
TO RAISED
°°
5 T 1
o SHADED WALLS ARE �
M
T
'
SLAB FLOOR AREAS
z
FOUNDATION WALL o
7543
' ° °
-a-;-" " '
o INSULATED (R-21) 2 x 3'-101/2" c, 4' 2"
- 0
(TYP)
O o
REGISTERE
a .- -°- _
°° "°"
CONC. FOUNDATION WALL PER
w 6 FURRING WALLS
�
ARCHITECT
-
°
STRUCTURAL DRAWINGS
� ADJACENT TO �
3068
_
" � -
CRAWL SPACE
� FOUNDATION WALLS �
o
///�,�
° _-
(TYP) o� 2670
�
GT'� ,
N
r
PAIR 3068 �
T
FREN H DOORS
CARL J. COLSON
�
-
`� DASHED LINES INDICATE WALLS OF
�
-
SATE OF WASHINGTO
3' - 6"
VENT PANTRY ABOVE. USE P.T. WOOD SILL -
TO SIT ON GARAGE FLOOR SLAB @
868 Wet ar N
�— t-
- -
`4'
� �
� - - -, HOSE
4" 5'•= 8" _• SIBB; ,
�,
_
� 41/2" 11; 71 1 M
THIS AREA
- -
ISSUED FOR PERMIT 1-21-2020
i
TYPICAL EXTERIOR WALL CONSTRUCTION. SEE
-
4
Crawl Space 16o s.f.
=�
10' - 0" . , •
�
SHEET A-4.1 FOR NOTES
� -
o Bath
�
WETBAR WI SINK, REF.,
Document Set Type:
i
°
2030 SOLID DOOR (WI RIGID �
MICROWAVE. COORDINATE
_
BUILDING
INSULATION ADHERED TO BACK)
LOCATIONS W/OWNER &
•1
� _, BUILDING
GARAGE
SECTION 4
FOR ACCESS TO CRAWL SPACE.
CABINET DESIGNER
B
0
� - SECTION
Revision Schedule
-
2030 2668
LEVEL 1 : ELEV. 0'- 0"
� 1
SUPPORT POST, FOOTINGS,
Guest Bedroom =
`r
� _ o'
1
` Patio- —
Rev.
i
i
(SEE SITE PLAN FOR
T A-4.2
FLOOR FRAMING
SEE STRUCTURAL DRAWINGS FOR -
0
� �
�` _• �'
o A-4.2
� _ �
�` Date Description
�
ACTUAL ELEVATION) I
LOCATIONS OF ALL SUPPORT �
0
�
r
�
i
I
POSTS &FOOTINGS FOR FLOOR `�
r
1
6-15-2020
Add Window /Permit Revisions
— — — — — � VET FRAMING BEAMS @CRAWL i
i
EXTEND SIDING BELOW THIS WALL @
SPACE. SEE STRUCTURAL
SHADED WALLS ARE
o
i _
NORTH EDGE OF GARAGE -SEE
DRAWINGS FOR SIZE OF SUPPORT \,
INSULATED (R-21) 2 x 6
_
- ' �''
r
� _ - - - • -
_ _ _ _
°T FOUNDATION PLAN FOR LOCATIONS o POST &CONCRETE FOOTING (TYP) 1" � �, FURRING WALLS ADJACENT N - - � -`� - - - - LOCATION OF PORCH COLUMNS.
i
i r
CONC. FOUNDATION WALL PER
T -
�,, 8' -10"
TO FOUNDATION WALLS (TYP)
- -
T ;• -
- �
_ . _ _ _
- - -' I SEE LEVEL 1 FLOOR PLAN FOR
• T LOCATION & DIMENSIONS OF
i
i
STRUCTURAL DRAWINGS
VENT -
- - -
"' COLUMNS.
TOP OF CONC. WALL :ELEV. (-) 1'-2 1/4"
-
° d °"
- �
S
. - _ _ EESTRUCTURALDRAWINGS
�
(-1.17')
�� � �� � ��
7 - 3 4 - 8 7 - 5
� �� � ��
7 - 9 4 - 5
° =o
- FOR SIZE OF SUPPORT POST &
CRAWL SPACE VENTS Iwl INSECT
o CONCRETE FOOTING (TYP)
�
DRAWING USE NOTIFICATION
�
-�
> CONC. GARAGE SLAB
SCREENS) IN CONCRETE
FOUNDATION WALLS
FOUNDATION
WALL STEP
FOUNDATION �
WALL STEP `�
`"
�,
This set of drawings is being issued as a Progress or Permit Set of Drawings
� - °
�
VENTS SHALL BE 8" X 16".VENTS
and is subject to change and adding of additional information and
_
°
a a _
°
_ 1
�
TO BE INSTALLED IN CONCRETE
_
SLOPING GRADE @THIS END OF HOUSE
drawings as required by review of the Building Department in the
- ' - ; - ' a o
o - ° - a, "°
FOUNDATION WALL AND SHALL
jurisdiction where this project is located.
_
° ° °" �=°
`a a °° �; � . °
HAVE GALVANIZED STEEL VENT
2' - 0"
5' - 51/2" 2' - 0"
DO NOT USE THIS DRAWING FOR CONSTRUCTION UNLESS THIS
DRAWING HAS A BUILDING DEPARTMENT "APPROVED" STAMP
a -
� �
� ° ° � � ° � =� : .�a°
-
WELLS INSTALLED IN FINISH
APPLIED BY THE BUILDING DEPARTMENT UPON COMPLETION OF
a - _ - � - GRADE /TOPSOIL. 31' - 01/2" 9' - 51/2"
"�
_° - = a - "
dj
SEE CRAWL SPACE VENT CALC'S
THE PERMIT REVIEW PROCESS.
a - -
° �
ON THIS SHEET
North
Do not use this drawing for Bidding or Estimating Purposes unless
Foundation Walls
Basement Floor
Plan � �
authorized by Client. During Construction Phase, the Clients General
Contractor (Builder) or Developer shall be responsible for ensuring that all
1 1 2" = 1 �- ��
/ O
Finished space
0 1 4" = 1 r- 11
not approved � 0
C RA W L S PAC E VENTING CALCULATIONS
Construction Personnel of the General Contractor and all Subcontractors
are supplied with all Approved and most current documents.
for use as an Accessory CONTRACTOR NOTE:
SEE BASEMENT/CRAWL SPACE PLAN OR EXTERIOR ELEVATION SHEETS& FOUNDATION DIMENSION
ARCHITECTURAL COPYRIGHT
THIS DRAWING I S NOT THE ONLY FOUNDATION
LAYOUT PLAN FOR LOCATION OF CRAWL SPACE VENTS. ALL CRAWL SPACE VENTS SHALL HAVE WIRE
Dwe I I i n g Unit. Separate
I a n d PLAN. THIS PLAN WAS DONE TO SHOW
INSECT SCREENS. CRAWL SPACE GROUND SURFACE SHALL BE COVERED BY CLASS 1 TYPE VAPOR
This sheet of drawings may not be reproduced in any form without prior
use a rova
DIMENSIONS FOR LAYOUT
I i s
OF BASEMENT AND
MATERIAL.
approval of Carl).Colson-Architect PLLC.
These document, the ideas, and designs incorporated herein as an
permit p p FOUNDATION PLAN.
VENTS SHALL BE 8" X 16". VENTS TO BE INSTALLED IN CONCRETE FOUNDATION WALL
instrument of service shall remain the property of Carl J. Colson -Architect
required .
AT FRONT YARD WHERE FINISH GRADE IS HIGHER, VENTS SHALL HAVE GALVANIZED STEEL VENT WELLS
PLLC and are solely for the use on this project only. These files, drawings,
THIS DRAWING DOES NOT SHOW LEVEL 1 FLOOR
INSTALLED IN FINISHGRADEITOPSOIL.
ideas, or designs may not betramsmittedelectronicallywithoutexpress
FRAMING, BEAM SUPPORT POSTS OR FOOTINGS.
THE MINIMUM NET AREA OF VENTILATION OPENINGS SHALL BE NOT LESS THAN 1 SQUARE FOOT FOR
permission of Architect. They are not be used by the client or any other
SEE STRUCTURAL DRAWINGS FO R AD D ITI ONAL
EACH 150 SQUARE FEET OF UNDER -FLOOR SPACE AREA., UNLESS THE GROUND SURFACE IS COVERED
party or entity on other projects, in whole or part, or as an extension to this
INFORMATION
BY CLASS 1 VAPOR RETARDER MATERIAL. WHERE A CLASS 1 VAPOR RETARDER MATERIAL IS USED, THE
project except by agreement in writing with appropriate financial
MINIMUM NET AREA OF VENTILATION OPENINGS SHALL BE NOT LESS THAN 1 SQUARE FOOT FOR EACH
compensation to Carl J. Colson -Architect PLLC.
O
1,500 SQUARE FEET OFUNDER-FLOOR SPACE AREA. ONE SUCH VENTILATING OPENING SHALL BE
Copyright Carl J. Colson -PLLC, 2019. All rights reserved.
WITHIN 3 FEET OF EACH CORNER OF THE BUILDING
Project Number
MINIMUM CRAWL SPACE VENTS -SEE PLAN FOR LOCATIONS
VENTED CRAWL SPACE BELOW LIVING ROOM 367 S.F.
Sheet Issue Date
1 S.F. OF VENT AREA PER 300 S.F. OF FLOOR AREA (367 DIV. BY 300) 1.22 S.F.
07/03/18
�
VENT SIZE 8"x16" (.75 S.F. FREE(AREA PER VENT)
R E S U B
Drawn e y
NUMBER OF VENTS REQUIRED 1.22 DIVIDED BY .75 2 VENTS MIN.
)
�_II cc ��nn??nn�
VENTED BELOW MUD ROOM
Author
Basement Plan
CRAWL SPACE /REAR HP,�I�A�7'LAtJIV1�RY 204 S.F.
1 S.F. OF VENT AREA PER 300 S.F. OF FLOOR ARE�'��M—vices .68 S.F.
Scale
VENT SIZE 8"x16" (.75 S.F. FREE AREA PER VENT) DEPARTMENT
As indicated
Sheet Plot Dat�/14/2020 7:34:28 PM
NUMBER OF VENTS REQUIRED (0.68DIVIDED BY .75) 1 VENT MIN.
www.CarlColsonArchitect.com
BUILDING AREA CALCULATIONS
LEVEL 1 FLOOR AREA (HEATED)
1168 S.F.
LEVEL 2 FLOOR AREA (HEATED)
1108 S.F.
BASEMENT FLOOR AREA (HTD)
631 S.F.
TOTAL FLOOR AREA (HEATED)
2907 S.F.
GARAGE AREA
764 S.F.
ENTRY PORCH
226 S.F.
DINING /KITCHEN PORCH
141 S.F.
BASEMENT PATIO
163 S.F.
SITE AREA CALCULATIONS
LOT SIZE
11,731 S.F
FOOTPRINT
2299 S.F.
LOT COVERAGE
19.6%
IMPERVIOUS AREA CALCULATIONS
COVERED ROOF AREA
2616 S.F.
SIDEWALKS, DRIVEWAY
733 S.F.
TOTAL IMPERVIOUS AREA
3349 S.F.
EVANS RESIDENCE FLOOR FINISH SCHEDULE
(ALL MATERIALS TO BE SELECTED BY OWNER)
LEVEL 1 LIVING:
WOOD
LEVEL 1 DINING:
WOOD
LEVEL 1 KITCHEN:
WOOD
LEVEL 1 MUD ROOM:
WOOD
LEVEL 1 BATH:
TILE
LEVEL 1: LAUNDRY
TILE
LEVEL 1: PANTRY
WOOD
STAIRS:
WOOD
ENTRY PORCH:
SYNTHETIC WOOD DECKING
LEVEL 2: BEDROOMS
CARPET
LEVEL 2: HALL
CARPET
LEVEL 2: BATHROOMS
TILE
WALL FINISH SCHEDULE
(ALL PAINT COLORS &SHEENS SELECTED BY OWNER. KITCHEN
AND BATHROOMS SHALL HAVE TILE BACKSPLASH).
LEVEL 1:
ALL ROOMS: GYP. BD: LEVEL 4 FINISH
LEVEL 2:
ALL ROOMS: GYP. BD: LEVEL 4 FINISH
GARAGE:
GYP. BD: LEVEL 3 FINISH
SHOWERS:
AS SELECTED BY OWNER
TUB /SHOWER:
AS SELECTED BY OWNER
OCCUPANCY SEPARATION BETWEEN
GARAGE &MECHANICAL ROOM AND
LIVING SPACE
CEILINGS: 1 LAYER OF 5/8" TYPE X G.W.B. ON ALL
TRUSSES AND TJI's (1 LAYER ON STICK FRAMING
� 16" O.C. OR LESS) WHERE HABITABLE SPACE
IS ABOVE GARAGE.
WALLS: 1 LAYER OF 1/2 G.W.B. ON COMMON
WALLS TO ROOF SHEATHING / 1 LAYER ON
WALLS TO SUPPORT PROTECTED CEILINGS
POSTS AND BEAMS: 1 LAYER
DOOR TO LIVING AREA: INSTALL 1-3/8" SOLID
CORE WOOD DOOR WITH SELF CLOSER AND
WEATHERSTRIPPING
ROOM FINISH SCHEDULE
CONTRACTOR TO COORDINATE ALL FINISH
SELECTIONS &FINISH ALLOWANCES W/ OWNER
FLOORING: ALL ROOMS, EXCEPT BATHROOMS,
LAUNDRY ROOM, AND MASTER BEDROOM
CLOSET SHALL HAVE WOOD FLOORING, AS
SELECTED BY OWNER.
WALLS AND CEILINGS IN LIVING AREAS: ALL
DRYWALL WALLS AND CEILING IN LIVING AREAS
SHALL HAVE A PAINTED, SMOOTH, LEVEL 5
DRYWALL FINISH. COLOR SELECTED BY OWNER.
WALLS AND CEILINGS IN GARAGE: ALL
DRYWALL WALLS AND CEILING IN GARAGE
SHALL HAVE A PAINTED, SMOOTH, LEVEL 4
DRYWALL FINISH. COLOR SELECTED BY
OWNER.
COUNTERTOPS: ALL BATHROOM AND KITCHEN
COUNTERTOPS SHALL BE QUARTZ (SELECTED
BY OWNER). THE LAUNDRY ROOM COUNTERTOP
SHALL BE A CORIAN FINISH, SELECTED BY
OWNER.
FOUNDATION SUB NOTE:
HOLD TOP OF CONCRETE
PLINTH BELOW TOP OF
DRIVEWAY PAVING @THIS
COLUMN. SEE
STRUCTURAL DRAWINGS
BUILDING
SECTION
1
A-4.1
PTD. HOLLOW METAL
(INSULATED) OR
FIBERGLASS DOOR .
SELECTION BY OWNER
3' x 4"GONG. LANDING
OUTSIDE OF THIS
DOOR W/STEPS TO
GRADE. RAISE FOUND
WALL @DOOR AREA -
BUILDING
SECTION
1
A-4.2
���
0
r`
M
�:3
' " � ' � . • � � � _ SEE SITE PLAN FOR LAYOUT OF
,� � ' ' �: � DRIVEWAY &ENTRY WALK � , 17 =
8�� 7�� 10' 3" 8' t01/4"
. .. . -,- - � -"- - - ,�- - , ",- ,- ". I �
-�� - �� � - -" -, -`- - -- -- --, , . I
- - , - - -- ..- - - - - - - ,� r - - - - - - � I
�� j I I I
- - � _ - �" � � �" � � - � - - ." - � - I I I I
- . � � -: Iariv�wa�- . �_ - - - -� - - _•- I I I I
- _ - �, r - -, � I I II
" ;" - - - -� _.� '� - � _ � — -= = _ - --= - -.--- __ III I
- . � _ -, - I
_ 1" � II � v e o IIII
,� 'T I
,' - � �� � . i G . , :• HOSE. i II i 7 -4 3 -4 A I i 3 -5 6 -31�
- � I, .I � 30 BIBB
�. �' �36-. �. o
c� _ �+
- ,- - - - - _, - - , - - . _, - - - � -��-� �� 6
- -
I I I •— — T --
9" x 8' OVERHEAD GARAGE DOORS II II THIS FIREPLACE TO VENT THROUGH I � 11
I W/AUTOMATIC OPENER. SEE I I ROOF. SEE LEVEL 2 AND ROOF PLAN I
I DOOR SCHEDULE III I I I 1 �
I I I I --- --------------------------�
I I I I Living Room i
I III I I I �
I I I I � SLOPED CEILING ABOVE LIVING ROOM i>
I I I I Im
I III I I 3 Car Garage I � DORMER ABOVE THIS AREA i �
I I I I /� DETECTORS &ELECT. SWITCHES I OUTLETS i�
I THESE WINDOWS MULLED I I 17 ��� 19 I REFER TOSHEET A-2.4 FOR ALL SMOKE & i o
TOGETHER III I I I CARBON MONOXIDE DETECTORS, ELECTRICAL i
L------------- �----J L------------------- FIXTURES, EXHAUST FAN, AND SWITCHES �
CONCRETE SLAB IN GARAGE IS III ADD CONCRETE CRACK CONTROL JOINTS IN SLAB AT o _ _ _ �
TO SLOPE TO DRAIN TOWARD GARAGE SLAB (SEE BSMT. FOUNATION PLAN) AND � FRAMER NOTE: ALL PLYWOOD SUBFLOOR
EXTERIOR AT GARAGE DOORS III DRIVEWAY. CONTRACTOR SHALL TOOL JOINT. INSTALL T IS TO BE ADHERED TO JOISTS WI
� CONCRETE CONTROL JOINTS (120 S.F. MAX.) PRIOR TO SUBFLOOR ADHESIVE AND SCREWS PER
GARAGE WINDOWS HEAD HEIGHT STRUCTURAL DRAWINGS (TYP)
INSTALL GARAGE WINDOWS HEAD FRAMING WALLS. THESE JOINTS ARE TO BE INSTALLED
HEIGHT @ 7'-0" ABOVE LEVEL 1 I TO MINIMIZE CRACKING OF CONCRETE SLABS. WALLS wl CROSSHATCH ARE 2 x 6 STUDS (TYP)
FINISH FLOOR (TYP @GARAGE) 23' - 5" -51/2" 4' - 0" 71/ " 6' - 4" 1' -1" 1' -
BUILDER NOTE: INSTALL R-38 TRIM CARPENTER NOTE: ALL CASED OPENINGS IN 2x6
BATT INSULATION @FLOOR WALLS SHALL BE TRIMMED WI PAINTED MDF CASING AT�'
AREA ABOVE GARAGE HEAD AND JAMBS AS SELECTED BY OWNER (TYPICAL) 26 `�
N
GAS &ELECTRIC METERS AT THIS I BOLD DASHED LINE INDICATES EXTENT OF FIRE
AREA. COORD. LOCATIONS WI OWNER SEPARATION BETWEEN GARAGE AND LIVING AREAS -
76" W x 96" H N
BEAM BELOW WALLS I STEEL BOLLARD 20 T - 7" N `' 21 CASED OPENING "'
ABOVE. SEE STRUCTURAL � � � > � W/ PTD. WD. TRIM _
DRAWINGS STRUCT. POST PAIR 3068 SOLID _ `, _ `�'
,� Furnace '
_ _ _ _� _ _ CORE DOORS W. y T �� w�' � "'
_ WEATHERSTRIPPING � 5/8" TYPE X GYP BD
HOSE GARAGE GYPSUM BOARD @WALLS WALLS &CEILING @
� BIBB ALL GYPSUM BOARD WALLS IN GARAGE SHALL BE TAPED, WOOD FRAMING MECHANICAL R00 -
FLOATED, AND PAINTED PER COLOR SELECTION BY OWNER �,, @ MECH ROOM HW � _
�"/ ' \l DASHED LINE INDICATES TOP OF CONC. FOUND. WALL � FLOOR T r
BELOW GARAGE FLOOR SLAB @THIS AREA �
v
28
7"
�,
_ - r,
II I
I I
I I 127
I I I -
I � I r`
II I
II
IIi I
I I 135
II I
I _
- I I I o
II I
I I
I I 115
� I
I I
I I p
o I
in II � o
II I
I I
I I
� r d I I
>r I ; I
I �I $
I I
I� I
II I
II
�_ �_��-= -= I
6' - 31/4" 2 3/4"
36 I I _
IN
3080
I -
Ch � �
I�
__ .. � 9
47" W x 84" H CASED
OPENING W/ PTD. WD. TRIM
\ T
N
2668
Bench
�
�,
-6"
6'-4"
1'-1"
3'-101/2"
3'-9" 1'-51/2"
3068 PROVIDE BLOCKING IN THESE WALLS FOR STAIR HANDRAILS
�
�
Dn
I
FRAMER &TRIM CARPENTER NOTE: SEE STAIR
�
`''
7 T @ 10"
Dinin
�
A
INFORMATION ON SHEET A-4.1 . STAIRWELL TREADS, -
i
�
5' -10"
DOOR &WINDOWS INFORMATION
RISERS, &RAILING I NEWEL POSTS SELECTION BY OWNER �
j
Up
REFER TO SHEET A-5.1 FOR ALL DOOR &
�.;
N
T
�
�,
WINDOW TYPES &SIZES
THIS PORTION OF PANTRY FLOOR FRAMING BUILT OVER
�
3' - 61/2"
N
12
�
FRAMER NOTE: ALL WINDOWS AT MAIN LEVEL TO
31
GARAGE FLOOR SLAB
`T'
�
�
8 T @ 10"
Up
o
HAVE A HEAD HEIGHT OF 8'-0" (TYP, UNLESS
STEPS UP TO LIVING AREA. SEE STAIR &STEP
�,
i
�
3' " 101/2"
�
6' -
8"
T
NOTED OTHERWISE COORDINATE WINDOW
)•
O
NOTES ON SHEET A-4.1
t
HEAD HEIGHTS WHERE ADJACENT TO DOORS SO
THAT HEAD HEIGHTS &HEAD TRIM ALIGNS (AT
_
'�
II I II I II II
3 - 6 8 - 5 2 -1 51/2
�,�-1
I II I II
-10 5 - 21/2
I II
13 - 6
LIVING ROOM &ENTRY HALL)
1 1 1 1 �� D n 3068
3' - 6" BUILT-IN BENCH
DOOR BETWEEN GARAGE
17 �� � � � C. �� � 29 AND DWELLING SHALL BE
1-3/8" SOLID CORE WI CLOSER
WEATHERSTRIPPING
-Dn
_ 3068 ud Room 25
� m
2868
Laundry
D�
�' � 13 33
T
� '� 0 D W
METALDRYERBOXIN
WALL /DOWN VENT
PLUMB FOR FLOOD SAVER
PAN @WASHING MACHINE
34
I/ FiUSt ��
� BIBB� 9'-2" I
1
7'-2"
N
_ �
-- J Pantry
5
N 2668
3'-5"
2668
Powder
14
3'-4"
7'-6"
2'-6"
5' - 41/2" �/ 7��
4'-7" 8'-1"
31' - 01/2"
40' - 6"
North
Level 1 Floor Plan
�1 4" = 1 '- "
O
�
KITCHEN LAYOUT IS
4'
4��
5, 8�,
SCHEMATIC. OWNER &KITCHEN �
PR. 3068
FRENCH DOORS
DESIGNER ARE TO SELECT
CABINET STYLE AND LOCATIONS
- -
_
10' - 0°
I
-
-
rJ
WA
L
_
- -
-
8' - 41/2" I
i ,
71/2" `;
4'xT OVN
- --
-
II
6
�
- I
I
1' - 0"
Island
24� --
'
N
I 2
""
o
I I D.
�, "'
-
I
I,
I
o
-
I
'"'
:THESE WINDOWS
i
=
Ir--- I 7
�
,"
.MULLED �
I ��
�
�
TOGET1iER
Kitchen �
o
�
I
��
I
I
-
o
�—"
I,
#
—
�
o
�
I
I
-
M
I•
_
o
T
I
I
t.
I
I
23
ADD WATER LINE FOR 2
r?'
��"
�
REFRIGERATOR &COFFEE
'_�'
" �
�. ;Covered . -� i
+
15
t`
MAKER. COORDINATE wl OWNER �
` "Porch
4 I
�.
,
I
.�"
; .
� 16
o
_;
" "' I
}
I
��
r
�
r
�
�=T
_ - _ -I
--.,,,
I
I r
I
I
15-11
_
��-.
"- - /
o
CV
1
--
I
J
i n i n�
6 -6 4 -81/2
i n
2 -0
I--- n i
-5 -51/2- 2 -0
n
- �
9'-51/2"
—
REAR VENTED GAS FIREPLACE. —
LINEFIREPLACE ENCLOSURE WI
5l8" TYPE X GYP. BOARD
LINE OF 15' WIDE SEWER EASEMENT
NOTES FOR LEVEL 1 FLOOR PLAN
TOILET CLEARANCES SHALL BE 15" FROM CENTER OF FIXTURE TO ADJACENT WALL OR
6 x 6 PRESSURE TREATED
COUNTERTOP. MIN. 30" CLEAR BETWEEN SIDE OR END WALL AND COUNTERTOP WITH TOILET
SUPPORT POST WI GALV.
FIXTURE AT MIDPOINT.
SIMPSON POST BASE
(WRAPPED PER DETAIL ON
� CONCRETE DRIVEWAY AT THIS AREA. SEE SITE PLAN AND GRADING PLAN FOR ADDITIONAL
SHEET A-4.2) IN
INFORMATION
CONCRETE FOOTING.
SEE STRUCTURAL
� KITCHEN CABINETS AND COUNTER LAYOUTS BY OWNER SELECTED KITCHEN DESIGNER.
DRAWINGS FOR ALL
KITCHEN PLAN SHOWN IS SCHEMATIC ONLY. OWNER TO SELECT KITCHEN CABINETS STYLE,
COLUMN /PORCH SLAB
LAYOUT, APPLIANCES, PLUMBING FIXTURES, AND COUNTERTOP MATERIALS
ATTACHMENT HARDWARE
o AND CONCRETE FOOTING
� LINE OF UPPER CABINETS ABOVE.
°O SIZE AND REINFORCING
(TYP)
4.) GAS RANGE / COOKTOP (SELECTION BY OWNER) W/ DOWNDRAFT EXHAUST VENT TO
OUTSIDE. COORDINATE SELECTION &INSTALLATION W/OWNER AND KITCHEN DESIGNER
ADJUSTABLE SHELVING IN PANTRY -HEIGHT, WIDTH, MATERIAL AND NUMBER OF SHELVES
TO BE SELECTED BY OWNER.
GAS WALL OVEN W/MICROWAVE.. COORDINATE SELECTION &INSTALLATION W/OWNER
AND KITCHEN DESIGNER
KITCHEN ISLAND W/ CABINETS BELOW AND SPACE FOR SEATING @END. DESIGN BY OWNER
AND KITCHEN CABINET DESIGNER.
BUILDING
� LINE OF ROOF OVERHANG ABOVE. SEE ROOF PLAN FOR INFORMATION.
SECTION
\`
� PRIMED AND PAINTED CEDAR WOOD TRIM AT ALL WINDOWS. SEE ELEVATION DRAWINGS.
1
VERTICAL TRIM BETWEEN WINDOWS THAT ARE SPACED 3" APART. SEE WINDOW SCHEDULE /
A-4.1
LEGEND FOR NOTES
1� MANUFACTURED GAS FIREPLACE (SELECTION BY OWNER). INSTALL PER ALL APPLICABLE
BUILDING AND SAFETY CODES. FIREPLACE MANTLE SELECTION AND INSTALLATION HEIGHT TO
BE COORDINATED W/OWNER. FIREPLACE TO BE VENTED THRU METAL FLUE THROUGH REAR
EXTERIOR WALL OR THROUGH ROOF (PER PLAN NOTE). INSTALL 5/8" TYPE "X" G.W.B. AT SIDES
AND TOP OF FIREPLACE ENCLOSURE PER CODE. INSTALL DIRECT VENT MANUFACTURED GAS
FIREPLACE IN ACCORDANCE W/MANUFACTURER'S SPECIFICATIONS AND STATE CODES
11. TILE RAISED HEARTH W/WOOD TRIM @ SIDES OF HEARTH (BELOW THE HEARTH SURFACE).
COORDINATE HEIGHT OF HEARTH, TILE WORK, WOOD TRIM WITH OWNER PRIOR TO FRAMING
HEARTH
1� STAIRS FROM LIVING AREA TO UPPER OR BASEMENT LEVEL. SEE STAIR NOTES ON SHEET
A-4.1.
WOOD STAIRS W/ PAINTED OR STAINED WOOD STAIR GUARDRAILS AND HANDRAILS. REFER TO
STAIR NOTES ON SHEET A-4.1 FOR INFORMATION. STAIR MATERIAL SELECTION BY OWNER
1� VINYL OR TILE FLOORING AT BATH AND LAUNDRY ROOM. SELECTION BY OWNER.
14. QUARTZ COUNTERTOP W/ UNDERMOUNT SINK W/MIRROR ABOVE AND WOOD CABINET
BELOW AT ALL BATHROOMS (TYP). SINK, COUNTERTOP, CABINETS, MIRROR, AND PLUMBING
FIXTURES SELECTION BY OWNER.
15. PORCH SUPPORT COLUMNS - RE: STRUCTURAL DRAWINGS FOR SIZE OF STRUCTURAL
POST. COLUMN SURFACE SHALL BE PAINTED SMOOTH CEDAR OVER 2 LAYERS OF BUILDING
WEATHER MEMBRANE OVER STRUCTURAL POST. REFER TO EXTERIOR BUILDING ELEVATIONS
FOR ADDITIONAL INFORMATION. ALL POSTS SHALL BE FLASHED TO AVOID WATER
PENETRATION WITHIN POST FRAMING ENCLOSURE. REFER TOPORCH COLUMN DETAIL
�
1� 36"HIGH RAILING (SEE GUARDRAIL NOTES ON SHEET A-4.1) AT REAR DECK AND REAR
�;, �
STAIRS TO GRADE. SELECTION OF HANDRAIL BY OWNER. COORDINATE INSTALLATION W/
MANUFACTURER AND BUILDING SAFETY CODE REQUIREMENTS. RAILING SHALL HAVE TWO
INTERMEDIATE EQUALLY SPACED 4 x 4 CEDAR POSTS. REFER TO ELEVATION DRAWINGS.
17. CONCRETE PORCH /WALKWAY /DRIVEWAY /GARAGE SLAB : (4" CONCRETE SLAB OVER
COMPACTED GRAVEL BASE) W/ EXPANSION &CRACK CONTROL JOINTS.
1� LOCATION OF ELECTRIC METER /PANEL AND GAS METER. INSTALL PER SAFETY CODES AND
REQUIREMENTS OF EACH UTILITY. COORDINATE METER LOCATIONS W/OWNER.
1� SEE NOTES ON THIS SHEET FOR SEPARATION REQUIREMENTS BETWEEN GARAGE /LIVING
SPACE /ATTIC SPACE
HOLD DECK SURFACE @PORCH 1-112"
BELOW FINISH FLOOR.
20. 3" DIAMETER STEEL BOLLARDS W/CAPS (CAST -IN -SLAB) TO PROTECT GARAGE WALLS
DECK SURFACE MATERIAL AND LAYOUT TO
FROM AUTO DAMAGE.
BE COORDINATED W/OWNER
21. HIGH EFFICIENCY GAS FURNACE AND WATER HEATER IN ENCLOSED /INSULATED ROOM.
PORCH WALKING SURFACE
COORDINATE LOCATION OF HEATER W/OWNER. VENT FURNACE &WATER HEATER TO
SYNTHETIC DECK BOARDS (SELECTION
EXTERIOR THROUGH MANUFACTURE APPROVED VENT PIPE.
BY OWNER) OVER JOIST FLASHING
MEMBRANES OVER PREESURE TREATED
22. PORCH ROOF SUPPORT COLUMNS W/WOOD WRAP -SEE COLUMN DETAIL ON SHEET A-3.1
FRAMING .
SEE STRUCTURAL DRAWINGS FOR DECK
23. COVERED DECK W/WATERPROOF WALKING SURFACE MEMBRANE (SELECTION &COLOR
FRAMING &FOUNDATION INFORMATION
BY OWNER) OVER PRESSURE TREATED PLYWOOD AND PRESSURE TREATED WOOD FRAMING
AND SUPPORT POSTS. REFER TO STRUCTURAL DRAWINGS FOR ALL DECK FRAMING
BUILDING
INFORMATION. DECK WATERPROOFING TO BE INSTALLED BY QUALIFIED &AUTHORIZED
SECTION
WATERPROOF MEMBRANE INSTALLER AND ALL FLASHING AND WATERPROOFING DETAILS
�_
SHALL BE INSTALLED PER WATERPROOFING MEMBRANE MANUFACTURERS REQUIREMENTS
1
AND SPECIFICATIONS.
A-4.2
DECK TO SLOPE TOWARD EXTERIOR. INSTALL METAL FLASHING &WATERPROOF MEMBRANE
PER MEMBRANE MANUFACTURERS DETAILS. INSTALL L-SHAPED METAL FLASHING AT THE
JUNCTION BETWEEN WALL AND DECK, A GRAVEL STOP DRIP AT THE EDGE, AND GALVANIZED
METAL PAN FLASHING UNDER THE DOOR.
24. DECK (AT DOORWAY) IS 2" LOWER THAN FINISH FLOOR LEVEL. DECK TO SLOPE (MIN. 1/4"
PORCH CEILING
PER FT) TO DRAIN TO EDGE .
PRIMED &PAINTED 1 x 4 T&G CEDAR
2� DOOR BETWEEN GARAGE AND DWELLING SHALL BE 1-3/8" SOLID CORE OR 20 MINUTE DOOR
BOARDS
2� ALL CASED OPENINGS IN INTERIOR 2x6 STUD WALLS SHALL HAVE PAINTED MDF BOARD
TRIM AS SELECTED BY OWNER AND COORDINATED WITH CONTRACTOR. ALL BASEBOARDS,
DOOR CASING, AND INTERIOR WINDOW CASING SHALL BE PAINTED MDF BOARD AS SELECTED
BY OWNER.
2� ENTRY PORCH &PORCH STEPS CONSTRUCTION: SYNTHETIC DECKING (AS SELECTED BY
OWNER) W/CONCEALED FASTENERS OVER PRESSURE TREATED WOOD FRAMING MEMBERS
AND SUPPORT COLUMNS (SEE STRUCTURAL DRAWINGS). INSTALL JOIST FLASHING MEMBRANE
(GRACE VYCOR PLUS FLEXIBLE FLASHING) AT TOPS OF ALL DECK FRAMING MEMBERS PRIOR
TO INSTALLING FINISH DECKING.
2� EXTERIOR STEPS FROM SIDEWALK TO ENTRY PORCH. COORDINATE NUMBER OF RISERS W/
ELEVATIONS OF FINISH GRADE AND PORCH DECKING.
29. BUILT-IN BENCH &COAT HOOKS @ MUDROOM ENTRY. COORDINATE W/ OWNER
3� THIS COLUMN AND BEAMS SUPPORT SECOND FLOOR WALLS ABOVE. SEE LEVEL 2 FLOOR
PLANS &STRUCTURAL DRAWINGS
3� BUILDER NOTE: THESE WINDOWS ARE SEPARATED AND SHALL HAVE PRIMED AND PAINTED
VERTICAL CEDAR TRIM BETWEEN ADJACENT WINDOWS
32. REAR VENTED GAS FIREPLACE @DINING PORCH. SEE PORCH SECTION DRAWING AND
NOTE #10 ABOVE FOR ADDITIONAL INFORMATION
3� WASHER &DRYER AND LAUNDRY SINK IN LAUNDRY ROOM. WASHER SHALL BE INSTALLED
W/ FLOODSAVER DRAINLESS BASE PROTECTION PAN (WWW.FLOODSAVER.COM) AND AN
ELECTRONIC WASHER FLOOD STOP SYSTEM (SAFEHOMEPRODUCTS.COM). DO NOT USE
FLOODSAVER PAN WITH DRAIN OR RIDGES. COORDINATE PLUMBING AND VENTING
REQUIREMENTS WITH MANUFACTURER. DO NOT VENT LAUNDRY VENT OR DRYER VENT THRU
FRONT WALL OF RESIDENCE.
3� LAUNDRY SINK -SIZE &TYPE SELECTION BY OWNER RESUB
.T.
OPER
WOOD FRAMIN STRUCTOURAL DSRAW NGS. IDSTALLGV���1����)'�1v1'E BRANEOJOIST
FLASHING TAPE OVER TO OF ALL FRAMING BELOW FRONaE�E����YP)
DEPARTMENT
36. STONE VENEER @THIS WALL. REFER TO EXTERIOR BUILDING ELEVATION DRAWINGS FOR
LOCATIONS AND REFER TO NORTH BUILDING SECTION FOR WALL ASSEMBLY @ AREA OF STONE
Carl J. Colson -Architect
PLLC
23623 20th Ave. W
Bothell, WA 98021
425-806-3703
wwwCarlColsonArchitect. com
Commercial &Residential
Architecture
Evans Residence
Project Address
20018 83rd Ave. W.,
Edmonds, WA 98026
New SFR at 20018 83rd Ave. W (Lot 1 of
PLN20180037)
City of Edmonds Permit #: BLD2020-0250 '`
Project Client 1
Marne &Simon Evans
20020 83rd Ave. W.
Edmonds, WA 98026
Sheet Title
Level 1 Floor Plan
7543 REGISTERE
ARCHITECT
G� '
CARL J. COLSON
S ATE OF WASHINGTO
ISSUED FOR PERMIT 1-21-2020
Document Set Type:
Revision Schedule
Rev.
# Date Description
1 6-15-2020 Add Window/ Permit Revisions
DRAWING USE NOTIFICATION
This set of drawings is being issued as a Progress or Permit Set of Drawings
and is subject to change and adding of additional information and
drawings as required by review of the Building Department in the
jurisdiction where this project is located.
DO NOT USE THIS DRAWING FOR CONSTRUCTION UNLESS THIS
DRAWING HAS A BUILDING DEPARTMENT "APPROVED" STAMP
APPLIED BY THE BUILDING DEPARTMENT UPON COMPLETION OF
THE PERMIT REVIEW PROCESS.
Do not use this drawing for Bidding or Estimating Purposes unless
authorized by Client. During Construction Phase, the Clients General
Contractor (Builder) or Developer shall be responsible for ensuring that all
Construction Personnel of the General Contractor and all Subcontractors
are supplied with all Approved and most current documents.
ARCHITECTURAL COPYRIGHT
This sheet of drawings may not be reproduced in any form without prior
approval of Carl J. Colson -Architect PLLC.
These document, the ideas, and designs incorporated herein as an
instrument of service shall remain the property of Carl J. Colson -Architect
PLLC and are solely for the use on this project only. These files, drawings,
ideas, or designs may not be tramsmitted electronically without express
permission of Architect. They are not be used by the client or any other
party or entity on other projects, in whole or part, or as an extension to this
project except by agreement in writing with appropriate financial
compensation to Carl J. Colson -Architect PLLC.
Copyright Carl J. Colson -PLLC, 2019. All rights reserved. O
Project Number
Sheet Issue Date �
03/28/13 �
Drawn By
Author Level 1 Floor Plan
Scale
As indicated Sheet Plot Dat�i/14/2020 7:34:51 PM
www.CarlColsonArchitect.com
AIR BARRIER /AIR INFILTRATION NOTES
AIR BARRIER: CONTINUOUS AIR BARRIER SHALL BE INSTALLED IN THE BDLG. ENVELOPE. BREAKS/JOINTS IN THE AIR BARRIER SHALL BE
SEALED. AIR PERMEABLE INSULATION SHALL NOT BE USED AS A SEALING MATERIAL. INSULATION SHALL BE INSTALLED PER MANUF.
GUIDELINES.
INFILTRATION: THE SEALING METHODS BETWEEN DISSIMILAR MATERIALS SHALL ALLOW FOR DIFFERENTIAL EXPANSION AND
CONTRACTION. THE FOLLOWING SHALL BE CAULKED, GASKETED, WEATHERSTRIPPED OR OTHERWISE SEALED WITH AN AIR BARRIER
MATERIAL, SUITABLE FILM OR SOLID MATERIAL:
1) SPACE BETWEEN WINDOWS/DOOR JAMBS &FRAMING AND SKYLIGHTS &FRAMING.
2) DUCTS, SHAFTS, UTILITY PENETRATIONS &FLUE SHAFTS OPENING TO EXT. OR UNCONDITIONED SPACE.
_
3) JUNCTIONS OF FOUNDATION &SILL PLATE & JUNCTION OF THE TOP PLATE & TOP OF EXT. WALLS.
DS
4) HVAC REGISTER BOOTS THAT PENETRATE BLDG. THERMAL ENVELOPE (SEAL TO SUBFLOOR/DRYWALL).
5) RECESSED LIGHT FIXTURES INSTALLED IN THE BLDG. THERMAL ENVELOPE SHALL BE AIR TIGHT, IC -RATED (SEALED TO THE DRYWALL).
6) BETWEEN GARAGE AND CONDITIONED SPACES.
DS
7) AIR BARRIER TO BE INSTALLED ON FIREPLACE WALLS - FIREPLACE TO HAVE GASKETED DOORS.
I
8) OPENINGS AT PENETRATIONS OF UTILITY SERVICES THROUGH THE ROOF, WALLS, AND FLOORS
I }
I
9) BUILDING ASSEMBLIES USED AS DUCTS OR PLENUMS
I
10) JOINTS, SEAMS, AND PENETRATIONS OF VAPOR RETARDERS
BUILDING I
11) ALL OTHER OPENINGS IN THE BUILDING ENVELOPE
SECTION III
WALL CORNERS & HDRS. SHALL BE INSULATED & SHALL BE SEALED. FLOORS, INCLUDING ABOVE GARAGE AND CANTILEVERED FLOORS -
INSUL. SHALL BE INSTALLED TO MAINTAIN PERMANENT CONTACT W/ UNDERSIDE OF SUBFLOOR DECKING. THE AIR BARRIER SHALL BE
1
� I
INSTALLED AT ANY EXPOSED EDGE OF INSUL. RIM JOIST SHALL BE INSULATED &INCLUDE AIR BARRIER.
A-4.1 I
CEILING/ATTIC -AIR BARRIER @DROPPED CEILING/SOFFIT SHALL REALIGNED W/THE INSUL. AND ANY GAPS IN AIR BARRIER SEALED.
I
ACCESS OPENINGS, DROP -DOWN STAIR, ETC. INTO UNCONDITIONED ATTIC SPACE SHALL BE SEALED. BATT INSUL. INSTALLED IN ATTIC
I I WALLS BELOW
ROOF ASSEMBLIES MAY BE COMPRESSED @EXT. WALL LINES TO ALLOW FOR REO'D ATTIC VENTILATION.
I � @LEVEL 1
(O � N
BATT INSULATION. SHALL BE CUT NEATLY TO FIT AROUND WIRING &PLUMBING IN EXT. WALLS WITHOUT VOIDS/GAPS. AIR BARRIER SHALL
III o � T
EXTEND BEHIND ELECTRICAL/COMMUNICATION BOXES OR INSTALL AIR SEALED BOXES.
I
EXTERIOR WALLS ADJACENT TOTUBS/SHOWERS TO BE INSULATED AND AIR BARRIER SHALL SEPARATE THE INSULATED WALL FROM THE
III � SLOPE
SHOWER/TUB.
I
III
TIPS Fi�R Ai1R SEALING THE BUILDING ENVELGPE ��; Seal Garner studs on exterior and interior walls
DS
�
I
Caulk drywall to tap and bottom plates - Seal vents and fans at penetration
8'-101/2"
��
—Seal all penetra#ions
�lapor retarder r'f f� `�
� ��
3 - 5 5' - 51/2" o
(If appropriate, Check local code requirements.) fy �, - ��� Seal windows and
E -
�
�-'" � �,� doors irsto rough
. .� r yv '�. �� openings
Lap exterior
sheathing
panels over
Entersec#ians
between
i2im Boards,
band joists and
plates andlor
seal at panel
joints and
around
edges.
Seal house
wrap or
building paper
to tap and
bottom plate -
Seal plumbing penetrations
- - Seal electrical boxes #a drywall
Seal electrical penetrations
Sea I ��,. �
exterior r
penetrations � � '�-�yf '"'�' ,
�'�''�. r •. � �,.
.. � ,�,, i�'fr,-'
Caulk between Rim Boards, , � - J
band joists and plates
STAIR REQUIREMENTS
THE STAIR DRAWING BELOW IS USED TO ILLUSTRATE BUILDING CODE
REQUIREMENTS FOR STAIRS.
CONTRACTOR SHALL COORDINATE SELECTION OF STAIR CONSTRUCTION
& RAILINGS OR HALF -WALLS WITH OWNER PRIOR TO FRAMING STAIRS
0
co
0
for r -
exterior
walls, seal
at tap and
bottom
plates �o
a ndlor
extend
exterior
sheathing
� aver joints
between �o
framing N
sections
Seal ductwork with mastic
Seal registers and HVAC penetrations
B..
BUILDING
SE�CTI�ON
1 \
A-4.2 /
NOTES TO LEVEL 2 FLOOR PLANS
DS
ua
r� # -
I�
— ���
---��
DS
� --_
L�
_-- _----
10' - 8"
II
�J
I
5 - 4 ��
5 �
- 4 ��
III
�
LINE OF PORCH
�
BEAMS BELOW
I
B
�
� SLOPE SLOPE -
� �
��,
B
-
�
DS ` �
=
WALLS BELOW @
LEVEL 1
I �
14 WINDOWS
13
I `� —
�,
---
I
MULLED
�
TOGETHER
16
�
_
_
-r, _�
_ � 1 T
���
--�_
-------------------- L
�
DS
5��
15
13 - 71/2 O�� i
�
. I
��
Bedroom #1
6068
�
M
I �
BIFOLD
r
T
o
�
i `"
SECTION
FRAMER NOTE: ALL PLYWOOD
OSUBFLOOR
IS TO BE ADHERED
�
�'
i
1
TO JOISTS WI SUBFLOOR
i �
_
�
A-4.1
ADHESIVE AND SCREWS PER
_o
OPEN TO LIVING ROOM BELOW N
STRUCTURAL DRAWINGS (TYP)
�
o
i
i
OF
�
WINDOWS MULLED TOGETHER
2' _ 0��
�
�
�
i r,
I N
I
PROVIDE BLOCKING @TOWEL
� �
i
� �
BARS &TOILET PAPER HOLDER.
i
� I �
COORDINATE LOCATIONS WI
_ ____________________L-J
�
11
OWNER (TYP @ALL BATHROOMS)
2868
PARTIAL ROOF OF DORMER SHOWN
DS
ONE-PIECE TUB I
�
15' - 71/2" �
I��
�
4' - 6" � � 1' - 4"
SHOWER.
SELECTION BY � o
�
�
���
13' - 31/2" - -
- - -
OWNER. 9
�
1' -10"
2 -4
13' - 9112" _ - -
- - i �
�I
r 6 2068
�
o
�
4
M
2668
`�
2868
O N
�i
5
$
`�'
O
� �
2868 OD
r
"'
o
M
�
�
M
� �� �- ��
2 -31/2 3 6112
� ��
5 -7
N
Master Bedroom 1' - 6"
3' 0"
DS
DN
DOOR &WINDOW INFORMATION
� �/
R�tt�
36"HIGH
REFER TO SHEET A-5.1 FOR ALL DOOR &
�
�Ai�
RAILING
WINDOW TYPES &SIZES. ALL WINDOWS AT �
��
�
Bedroom #2
UPPER LEVEL TO HAVE A HEAD HEIGHT OF �.;,
WINDOWS MULLED TOGETHER
-
T-0" (TYP)
FRAMER &TRIM CARPENTER NOTE: SEE
STAIR INFORMATION ON SHEET A-4.1
�
KYLIGH
ABOVE o
T
2 1
OPEN o
DETECTORS &ELECT. SWITCHES /OUTLETS
0
� �
.
6068
r
REFER TO SHEET A-2.4 FOR ALL SMOKE &
STAIRWELL TREADS, RISERS, &RAILING /
IFOLD
�
� �
TO M
-
CARBON MONOXIDE DETECTORS, �
�
w �
NEWEL POSTS SELECTION BY OWNER
BELOW
z
ELECTRICAL FIXTURES, EXHAUST FAN, AND M
o
�
�,
3 - 61/2 ��
_ J
�
SWITCHES
0
FRAMER NOTE: FRAME SKYLIGHT SHAFT
-
.,
i
LONGER THAN LENGTH OF SKYLIGHT
N
�
3'-101/2" N
T
N
�
i �
��
_
o
�
i o
r`
o
14' - 0"
2'
�i 1/2"
9' _ 5�� _�
�;,
j i "'
15' - 31/2" M
E
DN
i
G
3'-5" 10'-7"
�� crs
14-0------------ - - -- --- � ----
1Vlasfer�roseT- --- J
- - w
— — — � N �--------� c>
I �, � 22" x 42" ATTIC i i 2668 �
O ACCESS HATCH. � i �
H � _
� 72"x42"TILE �-- --�
� SHOWER 12 2668
� 6 /,
DS
��WALLS BELOW
@LEVEL 1
ALIGN SKYLIGHT wl
� LIGHT FIXTURES IN
� MASTER BATHROOM
� � SLOPE
o ao
I r r
II o
I�
I � �,
8'-2"
REFER TO ROOF PLAN FOR NOTES ON
ROOF CONSTRUCTION &FLASHING (TYP)
WALLS BELOW @LEVEL 1
LOWER ROOF BELOW. SEE ROOF PLAN ON
SHEET A-2.4 FOR ROOF SLOPE INFORMATION
@ THIS ROOF.
SEE STRUCT. DWGS FOR FRAMING LAYOUT &
SIZES (TYP)
T-5" 3'-7" � �
11' - 0" 4' ' 0�� VALLEY FLASHING
METAL FLASHING @ALL ROOF VALLEYS (TYP)
v � f\
1'-11" 3'-1"
N \
NO VENT STACKS FROM I DS !� PAINTED ALUMINUM GUTTERS AND
� ANY PLUMBING FIXTURES DOWNSPOUTS. SEE ROOF PLAN ON SHEET A-2.4
LOCATED ON SIDE OF r� FOR NOTES &DOWNSPOUT LOCATIONS(TYP)
ROOF FACING STREET �I�
' � � - 2068 "' °''
9 �I
- - � 11' - 81/2" 3' -10" 2' - 41/2" � I
_ _ 1 BUILDING
1 � SKYLIGHT ABOVE $ OG r' � o � � A-4.2 SECTION
� Master Bath � � � I � w �
- SAFETY GLAZING @ 10 � � � WRAPPED BEAM BELOW. SEE STRUCT. DWGS FOR
THESE WINDOWS 13 � `�' BEAM SIZES (TYP)
N I
� 2668 � � M � I LJ WRAPPED LOWER ROOF SUPPORT COLUMNS. SEE
J
F
J
7'-10"
M � LEVEL 1 PLAN FOR DIMENSIONS. SEE STRUCT. DWGS
' I FOR SIZES (TYP)
SLOPE SLOPE - ROOF SLOPE @LOWER ROOF
� SEE ROOF PLAN FOR SLOPES OF ALL ROOFS
� � � �� �� BIRD BLOCK EAVES
DS ' � �� �� �� � BIRD BLOCKS AT ALL EAVES
1' -11" D GUTTER GUARDS
INSTALL GUTTER GUARDS @ALL GUTTERS AT
TOILET CLEARANCES SHALL BE 15" FROM CENTER OF
FIXTURE TO ADJACENT WALL OR COUNTERTOP. MIN.
30" CLEAR BETWEEN SIDE OR END WALL AND
COUNTERTOP WITH TOILET FIXTURE AT MIDPOINT.
OPEN TO STAIRS /HALLWAY BELOW.
WOOD STAIRS W/ PAINTED OR STAINED WOOD
STAIR GUARDRAILS (36" HIGH) AND HANDRAILS.
REFER TO STAIR NOTES ON SHEET A-4.1 FOR
INFORMATION. STAIR MATERIAL SELECTION BY
OWNER
LINE OF WOOD HANDRAIL (36" HIGH) AT WALL AT
SIDE OF STAIRS.
SURFACE OF ROOF BELOW. SEE ROOF PLAN FOR
TYPICAL ROOF CONSTRUCTION INFORMATION.
ROOF GUTTERS BELOW.
SHELVES AT LINEN AND STORAGE CLOSETS.
COORDINATE TYPE OF SHELVES, NUMBER AND
HEIGHTS OF SHELVES WITH OWNER
POSSIBLE LOCATION FOR RETURN AIR DUCT /
DRILL. COORDINATE W/HVAC SUBCONTRACTOR
>3. TILE FLOORING AT BATH AND LAUNDRY ROOM.
SELECTION BY OWNER.
QUARTZ COUNTERTOP W/ UNDERMOUNT SINK W/
MIRROR ABOVE AND WOOD CABINET BELOW AT ALL
BATHROOMS (TYP). SINK, COUNTERTOP, CABINETS,
MIRROR, AND PLUMBING FIXTURES SELECTION BY
OWNER.
10. SOAKING TUB -SELECTION BY OWNER.
COORDINATE WHICH END SHALL HAVE PLUMBING
FIXTURES W/OWNER.
11. LINE OF PORCH ROOF SUPPORT COLUMN AND
BEAM BELOW -SEE LEVEL 1 FLOOR PLAN AND
STRUCTURAL DRAWINGS
12.) ATTIC HATCH ACCESS PANEL: 3/4" x 22" x 42"
(FITS INTO A 22'/2' X 42'h" ROUGH OPENING) W/ 5
LAYERS OFRIGID R-10 INSULATION ADHERED TO
PANEL @ATTIC SIDE. TRIM OPENING W/ PTD. 1 x 4
TRIM BOARDS
13.) BUILT-IN PAINTED WOOD SHELVES AND TRIM AT
THIS AREA. COORDINATE SELECTION AND NUMBER
OF SHELVES W/OWNER
14. LINE OF ROOF SUPPORT COLUMN AND BEAM
BELOW -SEE LEVEL 1 FLOOR PLAN AND STRUCTURAL
DRAWINGS
15. LOCATION OF CHIMNEY FLUE BELOW. ROUTE
FLUE FROM BELOW TO SHAFT IN BEDROOM
1� FIREPLACE TO BE VENTED THRU METAL FLUE
THROUGH THROUGH ROOF (PER PLAN NOTE).
INSTALL 5/8" TYPE "X" G.W.B. AT SIDES AND TOP OF
FIREPLACE ENCLOSURE PER CODE. EXTEND HEIGHT
OF FLUE ABOVE ROOF PER BUILDING CODE.
17. TILE SHOWER w/SAFETY GLASS DOORS. TILE
SELECTION BY OWNER. COORDINATE SIDE WALLS &
GLASS OFSHOWER w/ BATHROOM COUNTERTOP &
SIDE OF CABINETS.
5' - 5 3/8" � 6' -11" 3' - 7 5/8" 4' - 61/2"
ALL ROOFS. SEE NOTE @ RIGHT OF ROOF PLAN
10' - 6" 16' - 0"
PREFINISHED ALUMINUM GUTTERS &DOWNSPOUTS. SEE
ROOF PLAN FOR DRIP FLASHING NOTE @ROOF EDGE
FLOOR TRUSS MANUFACTURER &BUILDER NOTE:
� LINE OF WALLS BELOW (TYP)
DUCTWORK SHALL BE LOCATED IN THE FLOOR TRUSS AREA. FLOOR
TRUSSES SHALL BE DESIGNED TO ACCOMODATE MECHANICAL DUCTS.
BUILDER, MECHANICAL SUBCONTRACTOR, AND FLOOR TRUSS
MANUFACTURER TO COORDINATE DESIGN TO ALLOW FOR THIS DUCT
BUILDING AREA CALCULATIONS
INSTALLATION IN FLOOR TRUSS AREA TO PROVIDE HEAT AND
VENTILATION FOR THE BASEMENT AREA, LEVEL 1, AND LEVEL 2.
LEVEL 1 FLOOR AREA (HEATED)
1168 S.F.
LEVEL 2 FLOOR AREA (HEATED)
1108 S.F.
North
BASEMENT FLOOR AREA (HTD)
631 S.F.
�� Level 2 Floor Plan
TOTAL FLOOR AREA (HEATED)
2907 S.F.
�1� '_�"
1 �4" — 1
GARAGE AREA
764 S.F.
ENTRY PORCH
226 S.F.
DINING /KITCHEN PORCH
141 S.F.
BASEMENT PATIO
163 S.F.
SITE AREA CALCULATIONS
LOT SIZE
11,731 S.F
FOOTPRINT
2299 S.F.
LOT COVERAGE
19.6%
IMPERVIOUS AREA CALCULATIONS
COVERED ROOF AREA
2�s�� U
SIDEWALKS, DRIVEWAY
� 5 20 0
TOTAL IMPERVIOUS AREA
33�,�,��DMON
CE
DEPARTMENT
E E
Carl J. Colson -Architect
PLLC
23623 20th Ave. W
Bothell, WA 98021
425-806-3703
wwwCarlColsonArchitect. com
Commercial &Residential
Architecture
Evans Residence
Project Address
20018 83rd Ave. W.,
Edmonds, WA 98026
New SFR at 20018 83rd Ave. W (Lot 1 of
PLN20180037)
"City of Edmonds Permit #: BLD2020-0250
Project Client 1
Marne &Simon Evans
20020 83rd Ave. W.
Edmonds, WA 98026
Sheet Title
Level 2 Floor Plan
7543 REGISTERE
� ARCHITECT
G„�"� '
CARL J. COLSON
S ATE OF WASHINGTO
ISSUED FOR PERMIT 1-21-2020
Document Set Type:
Revision Schedule
Rev.
# Date Description
1 6-15-2020 Add Window/ Permit Revisions
DRAWING USE NOTIFICATION
This set of drawings is being issued as a Progress or Permit Set of Drawings
and is subject to change and adding of additional information and
drawings as required by review of the Building Department in the
jurisdiction where this project is located.
DO NOT USE THIS DRAWING FOR CONSTRUCTION UNLESS THIS
DRAWING HAS A BUILDING DEPARTMENT "APPROVED" STAMP
APPLIED BY THE BUILDING DEPARTMENT UPON COMPLETION OF
THE PERMIT REVIEW PROCESS.
Do not use this drawing for Bidding or Estimating Purposes unless
authorized by Client. During Construction Phase, the Clients General
Contractor (Builder) or Developer shall be responsible for ensuring that all
Construction Personnel of the General Contractor and all Subcontractors
are supplied with all Approved and most current documents.
ARCHITECTURAL COPYRIGHT
This sheet of drawings may not be reproduced in any form without prior
approval of Carl J. Colson -Architect PLLC.
These document, the ideas, and designs incorporated herein as an
instrument of service shall remain the property of Carl J. Colson -Architect
PLLC and are solely for the use on this project only. These files, drawings,
ideas, or designs may not be tramsmitted electronically without express
permission of Architect. They are not be used by the client or any other
party or entity on other projects, in whole or part, or as an extension to this
project except by agreement in writing with appropriate financial
compensation to Carl J. Colson -Architect PLLC.
Copyright Carl J. Colson -PLLC, 2019. All rights reserved. O
Project Number
Sheet Issue Date �
05/08/14 �
Drawn By
Author Leve12 Floor Plan
Scale
As indicated Sheet Plot Dat�/14/2020 7:35:13 PM
www.CarlColsonArchitect.com
THIS GUTTER @ROOF BELOW
DS
— � � DS
LOWER ROOF BELOW.
DS �,
L — — — LJ I
J � J u � ASPHALT COMPOSTION
4-1/2-in-12 ROOF SLOPE
ROOF SUPPORT BEAMS
ROOF SHINGLES
ROOFING SHINGLES
SYNTHETIC STONE I
WRAPPED VENEER @
BELOW. SEE STRUCT. DWGS.
30 YEAR GUARANTEED ASPHALT COMPOSITION SHINGLE.
SELECTION BY OWNER. SEE SHEET A-4.1 FOR ADDITIONAL
514 x 4 CEDAR TRIM
SIDES OF FIREPLACE FLUE
ROOFING INFORMATION
2x10 CEDAR RAKE BOARD
DS �
D
ENCLOSURE I
�
COVERED PORCH BELOW
METAL ROOF ALTERNATE BID
CONTRACTOR SHALL PROVIDE HOMEOWNER wl ALTERNATE PRICE
Carl J. Colson -Architect
�
y �
�
r �
/ _D_S_______ ____________
/ � METAL ROOF VALLEYS � I
ALIGN DOWNSPOUT WI CENTER OF
FOR METAL ROOFING AS SELECTED BY OWNER
ROOF FRAMING
PL L C
c''
______________� _ __
DS i DS �
o DS r �
COLUMN @PORCH BELOW (TYP @
PRE-ENGINEERED WOOD ROOF TRUSSES @ 24" O.C. WITH
23623 20th Ave. W
� FIREPLACE FLUE - - _
\ c ; LIJ � pS
DOWNSPOUTS @PORCHES)
OVERFRAMING AT INDICATED AREAS. ROOF TRUSS
� NOTE: ALL EXTERIOR TRIM SHALL BE
� FLASH PER INDUSTRY
�
MANUFACTURER WILL PROVIDE ROOF TRUSS FRAMING PLAN
Bothell, WA 98021
PRE -PRIMED AT ALL SIDES PRIOR TO
ii 9� STANDARDS. INSTALL
\ — — _ � I
(TYPICAL)
�, INSTALLATION (TYPICAL AT ALL
ii �FG� FLUE TO HEIGHT AS
/
PLUMBING VENTS
425-806-3703
/ LOCATIONS)
i �'� REQ D. BY CODE
�
� /
I
BUILDING
DO NOT INSTALL ANY PLUMBING VENTS TO ANY OF THESE ROOFS
VISIBLE FROM STREET. ROUTE ALL PLUMBING VENTS IN ATTIC TO
WWWCarlColsonArchitect.com
�SCHEDULEDSIDING SECTpION
/ 1 _ � I SHEET METAL ROOF —
� 2 x 8 CEDAR FASCIA � A-4.1 ��� I CRICKET @CHIMNEY
RIDGE VENT _
I
SECTION 1 �
A-4.1
VENTTHRUREARROOF.NOEXCEPTIONS!
Commercial &Residential
i FLUE ENCLOSURE.
DASHED LINE
'i
� DORMER OVER LIVING ROOM I
EAVE VENTS
BIRD BLOCK @ALL EAVES
FALL PROTECTION
CONTRACTOR SHALL INSTALL ROOF SAFETY ANCHORS PER
Architecture
MITER JOINT @INTERSECTION OF
INDICATES ICE -WATER
(TYP)
CODE IF REQUIRED (FASTENED TO ROOF TRUSS/FRAMING) FOR
2 x 8 FASCIA & 2 x 10 ROOF RAKE
i
SHIELD MEMBRANE
PROTECTION OF WORKERS ON ROOF
5/4 x 4 CORNER BOARD
�'
�� I BELOW SHINGLES
i
z
� '= - I
I��
ATTIC ACCESS HATCH 1 DOORS
•
Evans Res 1 d e n c e
(TYPp
i
�
SEE LEVEL 2 FLOOR PLAN FOR LOCATION OF ATTIC ACCESS
i >
DS
HATCH OR DOORS
Roof Rake Elevation
o
I
LI J -_,
DS
Project Address
2
I �
i
4-112-in-12 ROOF SLOPE @ LOWER �
ROOF VENTING @UPPER ROOF
ROOF IS TO BE VENTED WITH A COMBINATION OF ROOF RIDGE
20018 83rd Ave. W.,
�� � ��
1 = 1 -0
� I
ROOF (TYP)
VENTS &BIRD BLOCK VENTS. DISTRIBUTE BIRD BLOCK VENTS
ii
EVENLY AT EXTERIOR WALLS OF ATTIC SPACE
Edmonds, WA 98026
ii
SEE ATTIC VENTING CALCULATIONS.SEE NOTE BELOW FOR
ps
VENTING AT NORTH SIDE OF ROOF.
DS
New SFR at 20018 83rd Ave. W (Lot 1 of
SCHEDULED ROOFING
i
GUTTER GUARDS @ALL GUTTERS
ALL GUTTERS SHALL HAVE GUTTER GUARDS INSTALLED:
PLN2O18O037)
METAL DRIP EDGE �i � 2 x 2 BETWEEN ROOF
FLASHING �� LOOKOUTS
ii
'�
4-112-in-12 ROOF SLOPE @UPPER �
ROOF
PRIMED AND PAINTED
SMOOTH FINISH ROOF
GUTTER GUARD BY GUTTERGLOVE
4 FT. STAINLESS STEEL 5 IN. MICRO -MESH GUTTER GUARD (10-
City of Edmonds Permit #: BLD2020-0250
�� j
�
PACK) -COVERS 40' OF GUTTERS
� �
iDS
EXPOSEID EAVES AT ROLL
Project Client
SEE SHEET A-2.3 AND A-4.1
5l4 x 4 PRIMED & FOR NOTES ON ROOF
�
DS
DS
ROOFS (TYP)
M lrrle & S1IYlOTI EV 111S
PAINTED CEDAR
TRIM OVER 2x10 CONSTRUCTION &ROOF
ALL ROOF AREAS TO BE VENTED W/
20020 83rd Ave. W.
SLOPES
CEDAR RAKE BOARD � ATTIC SPACE —
PRIMED &PAINTED PLYWOOD ROOF
SHEATHING @OVERHANG PRIMED &PAINTED CEDAR 2 x
ROOF RIDGE VENTS AND BIRD �
22" x 22" SKYLIGHT BLOCKS @EAVES (TYP)
ON P.T. CURB w/
METAL FLASHING RIDGE VENT
Edmonds, WA 98026
10 FRIEZE BOARD
Sheet Title
NOTE: ALL EXTERIOR TRIM SHALL BEPRE- EXTERIOR GRADE SEALANT I
��
PRIMED AT ALL SIDES PRIOR TO � CAULKING
INSTALLATION (TYPICAL AT ALL I ��� GABLE END ROOF TRUSS
Skyl'ght
RIDGE VENT K
� RIDGE VENT
R o o f P 1 an
LOCATIONS)
INSTALL SHINGLE -OVER RIDGE
� SCHEDULED SIDING THIS GUTTER @ROOF
VENTS (AT LOCATIONS SHOWN)
ROOF SLOPE
BELOW
VALLEY FLASHING
FOR ATTIC VENTILATION. SEE RIDGE VENT
SMALLER DASHED LINES ARE
LINE OF WALLS @LEVEL 1
ALL ROOFS SHALL HAVE A 4-1 /2" IN 12"SLOPE (TYP)
�T
-� Roof Rake Overhang at (� able Roof
METAL FLASHING OVER FLASHING
CALCULATIONS FOR ATTIC /ROOF
VENTING ON THIS SHEET
�
BELOW (TYP)
ROOF OVERHANGS
�
MEMBRANE @ALL ROOF VALLEYS (TYP) ��
__
'
�
---
16° OVERHANG @EAVES
\ / 11 ' 1'
�� 1 = 1 -0 LARGER DASHED LINES ARE I
�
� I
LARGER DASHED LINES ARE
12" OVERHANG @RAKES @GABLE ENDS
LINE OF WALLS @LEVEL 2
- 0
LINE OF WALLS @LEVEL 2
BELOW (TYP)
� � �
BELOW (TYP)
ROOF AREA CALCULATIONS
�
�
LOWER ROOF 1437 S.F. OF ATTIC AREA
7543
�°�
DS
DS
CCESS
�
UPPER ROOF 1532 S.F. OF ATTIC AREA
REGISTERE
UrajnEti9e
�a:�:
��
i I
HATCH BELOW
/
ALOL ROOF OVERHANGS
ARCHITECT
strip •°••:�°
WeatherSealaowel-applied membrane
•�°:�e;
I
�--- -- -� � �----
�
(EAVES AND RAKES) ARE 16",
�'
. :
i i � DS _
r
UNLESS NOTED OTHERWISE
,.".
-. , `.. •:
` � '' SiBp fa5hlll 18p@lf afld Sealed
9
i
DS �
L_-- ___-� DS -'
�
GUTTER GUARDS
INSTALL GUTTER GUARDS
G"'"`
�� i �,,
`.�•. F
i
- __ �
SMALLER DASHED LINES i
i PLUMBING EXHAUST VENTS I �
ii
ALIGN SKYLIGHT wl ABSOLUTELY NO PLUMBING �,
@ALL GUTTERS AT ALL
ROOFS. SEE NOTE @RIGHT
CARL J. COLSON
SATE OF WASHINGTO
' �` ' Kick-outflashing
�
ARE LINE OF WALLS @ -'-�
LIGHT FIXTURES IN i OR EXHAUST VENTS ON THIS LJ
OF ROOF PLAN
�, � �
LEVEL 1 BELOW (TYP) 'i
/ MASTER BATHROOM ii ROOF FACE TOWARD
��•�� ���� � ������ �� �:. h ���
ii
� i STREET VIEW
i
ISSUED FOR PERM/ T 1-21-2020
. � , :
. ,.. ,;. � Kickoutarltifascia
•'• �
� I
BUILDING
� 9�
I o� I
FG
BUILDING
tapEd 8nd SBaEd it
,.. ,rk.=�• 1 SECTION _
• "�
- ' ` .., ... , A-4.2 i
,` ... i
- -
i
� � F2j.
0 it +
i
_SECTION 1
A-4.2
Document Set Type:
�
._`;�.
� ' I
II I
Revision Schedule
;. " `��
' .��
����
LOWER ROOF BELOW. ii ��,
22" x 36" SKYLIGHT ii
LOWER ROOF BELOW
Rev.
4-1/2-in-12 ROOF SLOPE i �
i Q'
i
ON P.T. CURB w/ i r
LJ \�
# Date Description
i
i
METAL FLASHING i �
i
COVERED PORCH BELOW
I
J
NOrth
Roof Plan
,
6-15-2020
Add Window /Permit Revisions
Shingles Wall sheathing
', I
— — � w
�
�
�
DS �-- _______________________ DS L
---
i o
L---,
ROOFSUPPORTBEAMS
Roof Kick -out Flashing
� �-----
i i
'
BELOW. SEE STRUCT. DWGS.
i i
5 1 /4" 1 �-O��
DS DS iL �L
GUTTERS &DOWNSPOUTS
DS
PREFINISHED ALUMINUM
GUTTERS AND DOWNSPOUTS
DRAWING USE NOTIFICATION
ROOF GENERAL NOTES
ATTIC MINIMUM VENT CALCULATIONS
This Set of drawings is being issued as a Progress or Permit Set of Drawings
and is subject to change and adding of additional information and
THE CONTRACTOR SHALL REVIEW ALL ROOFING AND ROOFING FLASHING DETAILS WITH ROOFING
THE FOLLOWING CALCULATIONS PROVIDE THE "MINIMUM" VENTING AS REQUIRED BY THE 2015
ROOF ATTIC VENT CALC'S @LOWER ROOF
drawings as required by review of the Building Department in the
MANUFACTURER. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ROOF ASSEMBLY AND ROOFING
QTTIC ACCESS HATCHES
INTERNATIONAL RESIDENTIAL CODE. THIS CODE ALLOWS AREA OF VENTS REQUIRED TO BE
1) NEW ROOF AREA =1437
S.F. (VENT AREA REQUIRED :1437 DIVIDED BY 300 = 4.8 S.F.)
jurisdiction where this project is located.
DETAILS IN ORDER TO ACHIEVE A WEATHERPROOF ROOFING ASSEMBLY.
PROVIDE INSULATED ATTIC ACCESS HATCH AT LOCATIONS SHOWN ON UPPER LEVEL FLOOR PLAN.
1 /300TH OF ROOF AREA IF 50% OF VENTS ARE AT EAVE AND 50% OF VENTS ARE AT RIDGE AND
2) DISTRIBUTION OF VENTS: 50% @RIDGE = 2.4 S.F., 5O% @EAVES = 2.4 S.F.
DO NOT USE THIS DRAWING FOR CONSTRUCTION UNLESS THIS
ROOFING MATERIALS
ATTIC ACCESS HATCHES IN 1 HR. CEILING SHALL HAVE A 1 HR. FIRE RATING (IF 1 HR. CEILINGS ARE
IF A VAPOR BARRIER IS INSTALLED ON THE WARM SIDE OF ATTIC INSULATION.
3) MINIMUM NUMBER
OF VENTS
DRAWING HAS A BUILDING DEPARTMENT °APPRovED° sTAMP
REFER TO BUILDING SECTIONS FOR ADDITIONAL ROOFING MATERIAL NOTES AND TYPES.
SPECIFIED FOR THIS PROJECT)
ATTIC VENTING CALCULATIONS
RIDGE VENT (0.076
SQ. FT PER LIN. FT): 32 LIN. FT. OF RIDGE VENT (2.4 S.F. OF VENT
APPLIED BY THE BUILDING DEPARTMENT UPON COMPLETION OF
ROOF FRAMING
ATTIC ACCESS HATCHES SHALL BE 22" x 30" (MIN. SIZE) AND SHALL HAVE 30" MINIMUM
UNOBSTRUCTED HEADROOM IN ATTIC ABOVE THE OPENING.
( THE FOLLOWING CALCULATIONS ARE FOR THE MINIMUM ALLOWABLE VENTS. SEE ROOF PLAN FOR LOCATION OF VENTS.
AREA )
THE PERMIT REVIEW PROCESS.
Do not use this drawing for Bidding or Estimating Purposes unless
COORDINATE OPENING WITH ROOF FRAMING.
CONTRACTOR SHALL INSTALL VENTING TO MEET THE FOLLOWING MINIMUM REQUIREMENTS. ALL EAVE VENTING SHALL BE
BIRD BLOCK EAVE
VENTS (0.094 SQ. FT. PER BLOCK): 29 BIRD BLOCKS (2.4 S.F. OF
authorized by Client. During Construction Phase, the Clients General
REFER TO STRUCTURAL FRAMING DRAWINGS AND ROOF TRUSS MANUFACTURER FRAMING
DRAWINGS FOR ROOF FRAMING INFORMATION.
ATTIC $c CRAWL SPACE HATCHES INSULATION REQMTS.
DISTRIBUTED EVENLY TO ASSURE PROPER AIR FLOW THROUGH ALL PORTIONS OF THE ATTIC AREA. BIRD BLOCK VENTS SHALL VENT AREA)
Contractor Builder or Develo er shall be res onsible for ensurin that all
� � p p g
BE EVENLY DISTRIBUTED AT FRONT AND REAR WALL OF BUILDING TO OBTAIN PROPER AIR FLOW IN ATTIC SPACE. INSTALL COR- 4) MINIMUM VENT AREA REQUIRED : 5.10 S.F. OF VENT AREA
Construction Personnel of the General Contractor and all Subcontractors
ROOFTOP PENETRATIONS
ACCESS DOORS FROM CONDITIONED SPACES TO UNCONDITIONED SPACES (E.G., ATTICS AND
CRAWL SPACES) SHALL BE WEATHERSTRIPPED AND INSULATED TO A LEVEL EQUIVALENT TO
A -VENT BELOW SHINGLE LINEAR VENTS WHERE ROOF OVERHANGS OR WALLS ARE LESS THAN 5' TO PROPERTY LINE -USE
SOLID
are supplied with all Approved and most current documents.
NO PLUMBING VENT STACKS OR EXHAUST VENTS WILL BE ALLOWED ON FRONT PORTION OF
THE INSULATION ON THE SURROUNDING SURFACES.
EAVE BLOCKING IN THOSE AREAS).
BUILDING ROOF FACING THE STREET. ALL ROOFTOP PENETRATIONS, PIPES, VENT STACKS SHALL BE
ACCESS SHALL BE PROVIDED TO ALL EQUIPMENT WHICH PREVENTS DAMAGING OR
NOTE THAT ROOF PLANS MAY SHOW RIDGE VENTS IN EXCESS OF THE REQUIRED MINIMUM SHOWN IN THE CALCULATIONS
ARCHITECTURAL COPYRIGHT
FLASHED ACCORDING TO ACCEPTABLE INDUSTRY STANDARDS. RESPONSIBILITY FOR ALL ROOFTOP
COMPRESSING THE INSULATION. A WOOD FRAMED OR EQUIVALENT BAFFLE OR RETAINER IS
BELOW.
This sheet of drawings may not be reproduced in any form without prior
FLASHING DETAILS SHALL BE WITH GENERAL CONTRACTOR /ROOFING SUBCONTRACTOR.
REQUIRED TO BE PROVIDED WHEN LOOSE FILL INSULATION IS INSTALLED, THE PURPOSE OF
approval of Carl J. Colson -Architect PLLC.
ROOF ATTIC VENTING
WHICH IS TO PREVENT THE LOOSE FILL INSULATION FROM SPILLING INTO THE LIVING SPACE
VENT TYPES
These document, the ideas, and designs incorporated herein as an
SEE ATTIC VENTING CALCULATIONS FOR MIN. NUMBER OF VENTS
( )
WHEN THE ATTIC ACCESS IS OPENED AND TO PROVIDE A PERMANENT MEANS OF MAINTAINING
THE INSTALLED R-VALUE OF THE LOOSE FILL INSULATION.
50% OF VENTS SHALL BE INSTALLED AT EAVES AND 50% OF VENTS SHALL BE INSTALLED AT ROOF RIDGE.
instrument of service shall remain the property of Carl J. Colson -Architect
ALL EAVES SHALL HAVE BIRD BLOCK EAVE VENTS BETWEEN EXPOSED RAFTER TAILS. ALL ROOF
"SHINGLE
SKYLIGHTS
ATTIC VENTING SHALL BE ACCOMPLISHED WITH BIRDBLOCK EAVE VENTS, SHINGLE -OVER RIDGE VENTS, AND BELOW -SHINGLE
PLLC and are solely for the use on this project only. These files, drawings,
RIDGES SHALL HAVE -OVER" ROOF RIDGE VENTS. ATTIC VENTILATION: NET FREE
VENTS.
ideas, or designs may not be transmitted electronically without express
VENTILATING AREA SHALL NOT BE LESS THAN 1/150's OF THE AREA OF THE SPACE VENTILATED. A
VAPOR BARRIER (P.V.A. PAINT) WILL BE INSTALLED ON THE WARM SIDE OF ATTIC INSULATION. A
(IF USED ON THIS PROJECT) INSTALL SKLIGHTS ON PRESSURE TREATED 2x4 WOOD CURBS AND
BIRD BLOCK VENTS ARE BASED ON 3 2-1/2" DIAMETER HOLES PER VENT BLOCK NFVA = .094 SQ. FT. PER BLOCK
() ( )
permission of Architect. They are not be used by the client or any other
MINIMUM OF 1"AIR SPACE SHALL BE PROVIDED BETWEEN THE INSULATION AND ROOF SHEATHING
INSTALL WITH METAL FLASHING PER SKYLIGHT MANUFACTURERS REQUIREMENTS. SKYLIGHT
GLAZING SHALL BE LAMINATED SAFETY GLASS.
RIDGE VENT AREA (0.076 SQ. FT PER LIN FT)
party or entity on other projects, in whole or part, or as an extension to this
project except by agreement in writing with appropriate financial
AT EAVE VENT LOCATIONS.
SKYLIGHT WELLS
SHINGLE -OVER VENT (0.0625 SQ. FT. PER LIN. FT)
compensation to Carl J. Colson -Architect PLLC.
ROOF VALLEY FLASHING
Copyright CarlJ.Colson-PLL,c,2oI9. All rights reserved. cO
INSTALL CONTINUOUS EXPOSED METAL FLASHING (DARK BRONZE COLOR) OVER CONTINUOUS 36"
PROVIDE FLARED SKYLIGHT OPENING AT CEILING LEVEL WHERE SKYLIGHTS ARE INDICATED ON
ROOF ATTIC VENT CALC'S @MAIN UPPER ROOF
WIDE (MIN.) "GRACE ICE &WATER SHIELD MEMBRANE" AT ALL ROOF VALLEYS BELOW ROOFING
FLOOR AND ROOF PLANS.
1) NEW ROOF AREA =1532 S.F. (VENT AREA REQUIRED :1532 DIVIDED BY 300 = 5.10 S.F.)
Project Number
MEMBRANEAND SHINGLES.
ROOF GUTTERS /DOWNSPOUTS
SKYLIGHT WELL WALLS SHALL BE PAINTED 1/2" GWB OVER 2 x 6 STUD FRAMING (@ 16" O.C.) WITH
R-21 BATT INSULATION. BOTTOM LENGTH OF SKYLIGHT WELL SHALL BE 4'-0"MINIMUM OR AS
DIRECTED BY BUILDER.
2) DISTRIBUTION OF VENTS: 50% @RIDGE = 2.55 S.F., 50% @EAVES = 2.55 S.F.
3) MINIMUM NUMBER OF VENTS
••
Sheetlssue Date
INSTALL ALUMINUM GUTTERS AND DOWNSPOUTS AT LOCATIONS SHOWN ON ROOF PLAN AND
ROOF EDGE DRIP FLASHING
RIDGE VENT (0.076 SQ. FT PER LIN. FT): 33.6 LIN. FT. OF RIDGE VENT (2.55 S.F. OF VENT AREA)
03/28/13
�
BUILDING ELEVATIONS. PROVIDE BASKET STRAINER LEAFGUARDS IN GUTTERS AT TOP OF ALL
BIRD BLOCK EAVE VENTS (0.094 SQ. FT. PER BLOCK): 26 BIRD BLOCKS (2.55 S.F. OF VENT AREA)
RES U B
Drawn By
DOWNSPOUTS. ALL DOWNSPOUTS SHALL DRAIN INTO BELOW GRADE DRAINAGE SYSTEM .
INSTALL PAINTED METAL DRIP EDGE FLASHING AT BOTTOM &SIDE EDGES OF ROOF.
4) MINIMUM VENT AREA REQUIRED : 5.10 S.F. OF VENT AREA
Author
Roof Plan
CONTRACTOR TO COORDINATE THIS ITEM PRIOR TO FOUNDATION WORK. CONTRACTOR SHALL
ROOF GUTTER GUARDS
Jun 15 2020
Scale
COORDINATE PAINT COLOR FOR GUTTERS &DOWNSPOUTS WITH OWNER. PROVIDE AND INSTALL
CITY OF EDMONDS
SCREENED GUTTER GUARDS AT ALL GUTTERS.
ALL GUTTERS SHALL HAVE GUTTER GUARDS INSTALLED. GUTTER GUARD BY GUTTERGLOVE
DEVE D PARTMENRVICES
As indicated
Sheet Ptot Dat�/14/2020 7:35:45 PM
4 FT. STAINLESS STEEL 5 IN. MICRO -MESH GUTTER GUARD (10-PACK) -COVERS 40' OF GUTTERS
—
www.CarlColsonArchitect.com
I
I
- I
I
I
a_ I
I
I
I
— — — — — — � I
a I
I
� I-��
�LJ�
�t�l
- I
- I
I
Unexcavated Crawl Space
(Garage Slab Above) � � r �
r---,
I rn I
LIJ
I----J � J
O
4� ,_-----_, 4' ,,-----,, 4��
TO SWITCH � � � � � � O Off\ 0�:.��
ABOVE _ _ � � � � � CM ��
��' I' I I I I I _, TV / Rec Room
4�� � � COORDINATE PHONE &CABLE I
II TV OUTLET LOCATIONS wl
4 OWNER @THIS ROOM i
---- - O
� ORO O
O � — � DIMMER
Crawl Space
I ter_ --
I R I
4"
EXH.� FAN
Bath
CM ,
DIMMER • 4„ �
@ LIGHTS O
SCMD R
@ MIRROR � SMOKE /CARBON �� 4��
MONOXIDE DETECTOR �.:
I � �
/ �
i �
--_ __,
�� 4" 4"
O O�
Guest Bedroom ��
COORDINATE PHONE &CABLE �i
TV OUTLET LOCATIONS w/ II
OWNER @THIS ROOM I
I
SMOKE DETECTOR
i
4 ,,------- 4 ,
� O
SD � �
-,1 Basement Lighting Plan
PLUMBING & MECH. EQUIPMENT
The requirements below are not the only requirements for plumbing and mechanical equipment to be
installed in this residence. Contractor and subcontractors shall follow all applicable code and safety
requirements when installing these fixtures or equipment items.
IN ADDITION TO COMPLYING WITH ALL APPLICABLE PLUMBING REQUIREMENTS, THE PLUMBING CONTRACTOR SHALL
CONFORM TO THE ADDITIONAL FOLLOWING PLUMBING REQUIREMENTS:
PRESSURE REDUCTION VALVE ON WATER SUPPLY LINE AS REQUIRED BY APPLICABLE CODES AND WATER UTILITY.
* EXPANSION TANK REQUIRED ON HOT WATER TANK.
*VENT HOT WATER TANK RELIEF VALVE DIRECTLY TO EXTERIOR.
* HOT WATER HEATER MUST BE SEISMICALLY ANCHORED OR STRAPPED AT POINTS WITHIN THE UPPER ONE-THIRD
AND LOWER ONE=THIRD OF ITS VERITCAL DIMENSIONS. AT THE LOWER POINT, A MINIMUM DISTANCE OF 4" MUST BE
MAINTAINED ABOVE THE CONTROLS WITH THE STRAPPING.
* 1" AIRGAP REQUIRED ON DISHWASHERS
ALL PLUMBING FIXTURES SHALL COMPLY WITH FLOW RATES AS REQUIRED BY THE CITY OF EDMONDS CODE. THE
REDUCED FLOW FIXTURE RATES ESTABLISHED BY THE WASHINGTON STATE ENERGY CODE SHALL NOT APPLY,
UNLESS NOTED AS AN ENERGY CREDIT OPTION ON SHEET A-6.1
* NO PLUMBING VENT PIPES OR PROJECTIONS SHALL BE ALLOWED ON FRONT FACING ROOF OF BUILDING. SEE
ROOF PLAN FOR NOTES.
THE WATER SUPPLY FOR DISHWASHERS SHALL BE PROTECTED BY AN AIR GAP OR INTEGRAL BACKFLOW
PREVENTER.
PROVIDE VENT FOR DRYER TO OUTSIDE (MAX 15' WITH 2-90°S).
EXTEND POP -OFF LINE FROM HOT WATER TANK OR BOILER TO THE FLOOR, TO AN INDIRECT WASTE RECEPTOR OR
TO THE OUTDOORS. WHERE DISCHARGING TO THE OUTDOORS IN AREAS SUBJECT TO FREEZING, DISCHARGE
PIPING SHALL BE FIRST PIPED TO AN INDIRECT WASTE RECEPTOR THROUGH AN AIR GAP LOCATED IN A
CONDITIONED AREA. SEE P2803.6.1 FOR COMPLETE INSTALLATION DETAILS.
CONDENSATE FROM ALL COOLING COILS OR EVAPORATORS SHALL BE CONVEYED FROM THE DRAIN PAN OUTLET TO
AN APPROVED PLACE OF DISPOSAL. CONDENSATE SHALL NOT DISCHARGE INTO A STREET, ALLEY OR OTHER AREAS
WHERE IT WOULD CAUSE A NUISANCE. A SECONDARY DRAIN OR AUXILIARY DRAIN PAN SHALL BE REQUIRED FOR
EACH COOLING OR EVAPORATOR COIL WHERE DAMAGE TO ANY BUILDING COMPONENTS WILL OCCUR AS A RESULT
OF OVERFLOW FROM THE EQUIPMENT DRAIN PAN OR STOPPAGE IN THE CONDENSATE DRAIN PIPING.
CONDENSATE LINES FROM HIGH EFFICIENCY HEATERS MUST BE LOCATED WHERE THEY ARE NOT SUBJECT TO
FREEZING.
INSTALL HEATING AND AIR CONDITIONING EQUIPMENT ACCORDING TO MANUFACTURER'S SPECIFICATIONS. WHEN IN
A CLOSET OR ALCOVE, THE SPACE SHALL BE A MINIMUM 12"WIDER THAN THE FURNACE WITH A MINIMUM 3"
WORKING CLEARANCE REQUIRED AT REAR, SIDES AND TOP OF FURNACE.
-- TO LANDSCAPE ��
LIGHTING
��
.� -
Level 1 Lighting Plan
A LEVEL WORKING SPACE AT LEAST 30 INCHES DEEP AND 30 INCHES WIDE SHALL BE PROVIDED IN
FRONT OF THE CONTROL SIDE TO SERVICE AN APPLIANCE.
APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE SOURCE OF
IGNITION IS NOT LESS THAN 18 INCHES ABOVE THE FLOOR IN GARAGES.
APPLIANCES SHALL NOT BE LOCATED IN SLEEPING ROOMS, BATHROOMS, TOILET ROOMS, STORAGE
CLOSETS OR SURGICAL ROOMS, OR IN A SPACE THAT OPENS ONLY INTO SUCH ROOMS OR SPACES.
SEE G2406.2 FOR EXCEPTIONS.
PROVIDE OUTSIDE COMBUSTION AIR TO ALL GAS APPLIANCES. EXCEPTION: DIRECT VENT
APPLIANCES WITH SEALED COMBUSTION CHAMBERS.
IF FURNACE &WATER HEATER ARE LOCATED IN GARAGE, PROVIDE 3" CONCRETE FILLED METAL
POST WITH A 2' EMBEDMENT AND WITH A 30" EXTENSION ABOVE THE FLOOR TO PROTECT
EQUIPMENT IN GARAGE FROM PHYSICAL DAMAGE UNLESS INSTALLED IN AN ALCOVE.
ALL HOSE BIBS TO BE FROST -FREE WITH BACK FLOW DEVICE.
TOILETS, MAXIMUM 1.6 GALLON PER FLUSH. SHOWERS AND FAUCETS, MAXIMUM 2.5 GALLONS PER
MINUTE.
AN EXPANSION TANK IS REQUIRED FOR ALL WATER HEATERS AND BOILERS. M2003
WATER HEATERS SHALL BE ANCHORED OR STRAPPED TO RESIST MOVEMENT DUE TO EARTHQUAKE
MOTION. STRAPPING SHALL BE PLACED WITHIN THE UPPER ONE-THIRD AND LOWER ONE-THIRD
DIMENSIONS OF THE TANK. THE LOWER STRAP SHALL BE A MINIMUM 4" ABOVE THE CONTROLS.
PROVIDE PAN WHEN OVER WOOD FRAMED FLOOR.
WHERE WATER HEATERS OR HOT WATER STORAGE TANKS ARE INSTALLED IN LOCATIONS WHERE
LEAKAGE OF THE TANKS OR CONNECTIONS WILL CAUSE DAMAGE, THE TANK OR WATER HEATER
SHALL BE INSTALLED IN A GALVANIZED STEEL PAN HAVING A MINIMUM THICKNESS OF 24 GAGE OR
OTHER PANS FOR SUCH USE. THE PAN DRAIN SHALL EXTEND FULL-SIZE AND TERMINATE OVER A
SUITABLY LOCATED INDIRECT WASTE RECEPTOR OR SHALL EXTEND TO THE EXTERIOR OF THE
BUILDING AND TERMINATE NOT LESS THAN 6 INCHES AND NOT MORE THAN 24 INCHES ABOVE THE
ADJACENT GROUND SURFACE. IRC P2801.5, P2801.5.2
SHOWER COMPARTMENTS SHALL HAVE AT LEAST 900 SQUARE INCHES OF INTERIOR CROSS-
SECTIONALAREA. SHOWER COMPARTMENTS SHALL BE NOT LESS THAN 30 INCHES IN MINIMUM
DIMENSION MEASURED FROM THE FINISHED INTERIOR DIMENSION OF THE SHOWER COMPARTMENT
�,
„' R �
4' �
i
LED LIGHTING BELOW UPPER CABINETS
LED LIGHTING BELOW UPPER CABINETS SHALL BE
INSTALLED TOWARD OUTER EDGE OF CABINETS. ALL LED
UNDER -CABINET LIGHTS SHALL BE ON SAME CIRCUIT
EXHAUST FAN n"M�
SWITCH FOR WALKWAY
& LANDSCAPE LIGHTING
ELECTRICAL LAYOUT
ALL LIGHT FIXTURE TYPES &LOCATIONS,
SWITCH LOCATIONS, AND WIRING
CONNECTIONS ARE SCHEMATIC ONLY.
ELECTRICIAN SHALL COORDINATE PURCHASE
OF ITEMS, LOCATIONS AND LAYOUT WITH
OWNER PRIOR TO INSTALLATION.
PHONE, CABLE. AND DATA LINE LAYOUT
CONTRACTOR SHALL COORDINATE LOCATIONS
OF ALL PHONE OUTLETS, CABLE TV OUTLETS,
AND CABLE OUTLETS FOR COMPUTERS WITH
OWNER -TYPICAL FOR ALL LEVELS
LANDSCAPE LIGHTING
LOW VOLTAGE LANDSCAPE LIGHTING IS TO BE
USED FOR THIS PROJECT, ELECTRICIAN SHALL
COORDINATE LOCATIONS & TYPES OF ALL
LANDSCAPE LIGHTING WI OWNER
REAR VENTED GAS FIREPLACE
COORD. IGNITER SWITCH &POWER
OUTLET LOCATION FOR BLOWER
FAN (IF ANY) WITH OWNER &
MANUFACTURER REQUIREMENTS
FIRE PROTECTION, ELECTRICAL, HEATING. SOLAR &VENTILATION GENERAL NOTES
FIRE PROTECTION SYSTEMS: ALARMS &SPRINKLERS
HIGH EFFICACY LIGHT BULB REQUIREMENTS
CODE STANDARD
A MINIMUM OF 75 PERCENT OF THE LAMPS (BULBS) IN PERMANENTLY INSTALLED
INTERNATIONAL RESIDENTIAL CODE, 2015 EDITION
LAMPS IN LIGHTING FIXTURES SHALL BEHIGH-EFFICACY LAMPS (THE OWNER HAS
INTERNATIONAL FIRE CODE
REQUESTED THAT 100% OF THE LAMPS BE HIGH EFFICACY.
COMPLIANCE METHOD:
VENTILATION &INDOOR AIR QUALITY
ENTIRE HOUSE TO RECEIVE SMOKE DETECTOR ALARMS LOCATED PER IRC SECTION R314. ALARMS ARE TO
SOURCE SPECIFIC VENTILATION
BE PERMANENTLY WIRED TO HOUSE'S POWER SOURCE AND HAVE BATTERY BACKUP, PER IRC SECTION
1. SOURCE SPECIFIC VENTILATION: SOURCE SPECIFIC EXHAUST VENTILATION SHALL
R314.4..
THIS HOUSE IS NOT REQUIRED TO BE SPRINKLERED
BE REQUIRED IN EACH KITCHEN, BATHROOM, WATER CLOSET, LAUNDRY ROOM, AND
OTHER ROOMS WHERE EXCESS WATER VAPOR OR COOKING ODOR IS PRODUCED.
SMOKE DETECTORS
1. BATHROOM EXHAUST.........................................50 CFM
2. KITCHEN EXHAUST (IF APPLICABLE)...............100 CFM
CONTRACTOR SHALL PROVIDE AND INSTALL SMOKE DETECTORS AS REQUIRED BY APPLICABLE SAFETY CODES.
3. LAUNDRY ROOM EXHAUST(IF APPLICABLE)......50 CFM
SMOKE DETECTORS SHALL BE HARD WIRED (110v) WITH BATTERY BACKUP.
WHOLE HOUSE EXHAUST FAN
CARBON MONOXIDE DETECTORS
WHOLE HOUSE VENTILATION SYSTEMS: DWELLING UNIT SHALL BE EQUIPPED WITH A
FOR NEW CONSTRUCTION, AN APPROVED CARBON MONOXIDE ALARM SHALL BE INSTALLED OUTSIDE OF EACH
WHOLE HOUSE VENTILATION SYSTEM WHICH SHALL BE CAPABLE OF PROVIDING AT
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS IN DWELLING UNITS WITHIN WHICH
LEAST 0.35 AIR CHANGES PER HOUR, BUT NOT LESS THAN 15 CUBIC FEET PER MINUTE
FUEL -FIRED APPLIANCES ARE INSTALLED AND IN DWELLING UNITS THAT HAVE ATTACHED GARAGES.
PER BEDROOM PLUS AN ADDITIONAL 15 CUBIC FEET PER MINUTE. WHOLE HOUSE
ELECTRICAL
VENTILATION SYSTEMS SHALL BE DESIGNED TO LIMIT VENTILATION TO A LEVEL NO
GREATER THAN 0.5 AIR CHANGES PER HOUR DURING NORMAL OPERATING
CONTRACTOR SHALL PERFORM ALL ELECTRICAL DESIGN AND INSTALLATION ON A DESIGN -BUILD BASIS AND
CONDITIONS.
SHALL APPLY FOR A SEPARATE PERMIT FOR ALL ELECTRICAL WORK.
WHOLE HOUSE FAN SIZE...............................100 CFM
1. CONTRACTOR SHALL COORDINATE ALL SELECTION OF ALL LIGHT FIXTURES, LIGHT FIXTURE LOCATIONS, AND
WHOLE HOUSE FAN NOISE RATING....1.5 SONE (MAX.)
ELECTRICAL OUTLET LOCATIONS WITH OWNER PRIOR TO PURCHASE OR INSTALLATION OF FIXTURES.
CONTROL REQUIRED: MANUAL AND AUTOMATIC CONTROL (24 HR. CLOCK TIMER)
2. CONTRACTOR SHALL COORDINATE ELECTRICAL OUTLET REQUIREMENTS FOR WASHER &DRYER UNITS
HEATING SYSTEM
WITH SELECTED MANUFACTURERS REQUIREMENTS.
3. REFER TO INDOOR AIR QUALITY NOTES FOR BATHROOM EXHAUST FANS AND WHOLE HOUSE FANS FOR
THIS RESIDENCE SHALL BE HEATED BY A GAS FIRED FORCED AIR FURNACE HEATING
RESIDENTIAL UNIT.
SYSTEM WITH FRESH AIR INTAKE FOR WHOLE HOUSE VENTILATION AND FRESH AIR
4. HEATING: THIS HOUSE SHALL BE HEATED WITH GAS HEAT PUMP WITH THERMOSTATS (PER WASHINGTON
INTAKE FOR COMBUSTION AIR.
ENERGY CODE). PROVIDE ELECTRICAL SERVICE AS REQUIRED BY MANUFACTURER.
THIS SYSTEM SHALL HAVE A HIGH EFFICIENCY HVAC AIR DISTRIBUTION SYSTEM. ALL
5. PROVIDE AND INSTALL EXHAUST FAN OVER KITCHEN RANGE.
DUCTWORK SHALL BE IN CONDITIONED SPACES. NO DUCTWORK ALLOWED IN CRAWL
6. ALL OUTLETS IN BATHROOM, KITCHEN, AND WET AREAS SHALL BE GFI OUTLETS.
SPACE AREAS.
7. LIGHT FIXTURES IN TUB OR SHOWER ENCLOSURES MUST HAVE LABEL STATING "SUITABLE FOR DAMP
LOCATIONS".
8. RECESSED CEILING FIXTURES MUST BE IC RATED.
9. ISLAND AND PENINSULA COUNTER TOPS 12" OR WIDER SHALL HAVE AT LEAST ONE RECEPTACLE OUTLET
FOR EACH 4' OF COUNTER TOP.
ELECTRICAL FIXTURE LEGEND
SMOKE &CARBON
MONOXIDE DETECTOR
SCMD
•
SMOKE DETECTOR
SD
\ ^ ,r
RECESSED LIGHT FIXTURE
R
4
4" DIAMETER
�
Carl J. Colson Architect
RECESSED LIGHT FIXTURE
DAMP LOCATION 5" DIAMETER
I �I
4°�
PLLC
�I
RECESSED LIGHT FIXTURE
DAMP LOCATION 4" DIAMETER
23623 20th Ave. W
\—/�
RECESSED LIGHT FIXTURE
Bothell, WA 98021
R�
5" DIAMETER
jj"
5
425-806-3703
RECESSED ADJUSTABLE LIGHT FIXTURE
��-y-��
t, R j
5" DIAMETER -DIRECTIONAL FOR ART
DISPLAY
wwwCarlColsonArchitect.com
5" D
P ��
KITCHENTISLANDFIXTURE @ENTRY PORCH &
Commercial &Residential
MIN. 34" ABOVE ISLAND
��
S-1 /SEMI -FLUSH LIGHT FIXTURE
Architecture
SF
Evans Residence
FXITUREMOU2TDEDLIGHT
CM 12" DIA.
Project Address
CEILING MOUNTED LIGHT
FIXTURE. SIZE SELECTED BY
OWNER
20018 83rd Ave. W.,
CM
WALL MOUNTED EXTERIOR
LIGHT FIXTURE
Edmonds WA 98026
WALL MOUNTED INTERIOR LIGHT
FIXTURE
New SFR at 20018 83rd Ave. W (Lot 1 of
PLN20180037)
���
WALL MOUNTED INTERIOR SCONCE
700 LUMENS
City of Edmonds Permit #: BLD2020-0250
O/�
EXHAUST FAN
Timer @Switch
EXHAUST FAN w/
EXH. FAN
TIMER @SWITCH
ELECTRICAL OUTLET
240
240 V OUTLET
WEATHER PROOF
ELECTRICAL OUTLET
WP
LIGHT SWITCH
��
LED UNDER CABINET LIGHTING
���
L.E.D. LINEAR SURFACE
MOUNTED LIGHT
O O�
CEILING FAN W/LIGHT
FIXTURE
00
1) PROVIDE AND INSTALL LOCALLYCERTIFIED SMOKE
DETECTORS AS REQUIRED BY THE NATIONAL FIRE PROTECTION
ASSOCIATION (NFPA) AND MEETING THE REQUIREMENTS OF ALL
GOVERNING CODES. SMOKE DETECTORS SHALL BE DIRECT
WIRED, 110 VOLT INTERCONNECTED WITH A BATTERY BACKUP.
2) PROVIDE AND INSTALL GROUND FAULT CIRCUIT
INTERRUPTERS (GFI) AS REQUIRED BY THE NATIONAL ELECTRIC
CODE (NEC) AND MEETING THE REQUIREMENTS OF ALL
GOVERNING CODES.
3) UNLESS OTHERWISE INDICATED, INSTALL SWITCHES AND
RECEPTACLES AT THE FOLLOWING HEIGHTS ABOVE FINISH
FLOOR:
SWITCHES 42"
OUTLETS 16"
TELEPHONE 16"
TELEVISION 16"
EXHAUST OUTLET TERMINATION
1.3 FEET MIN. FROM PROPERTY LINE
2.3 FEET FROM OPERABLE OPENINGS INTO A BUILDING.
3. 10 FEET FROM MECHANICAL AIR INTAKE.
4. ALL EXHAUST DUCTS IN UNCONDITIONED SPACE SHALL BE
INSULATED WITH R-4.
OUTSIDE FRESH AIR INTAKE
OUTSIDE AIR: OUTSIDE AIR SHALL BE BROUGHT INTO RESIDENTIAL
UNIT BY EXHAUST FANS /WHOLE HOUSE FANS WHICH WILL DRAW
OUTSIDE AIR IN THROUGH FRESH AIR INTAKE VENTS CONNECTED TO
AND OPERATED BY SELECTED HVAC SYSTEM. WHERE OUTSIDE AIR
SUPPLIES ARE SEPARATED FROM EXHAUST FANS POINT BY DOORS,
THE DOORS SHALL BE UNDERCUT BY'h INCH.
VENTILATION DUCTS: ALL DUCTS SHALL TERMINATE OUTSIDE THE
BUILDING.
1. ROOM FRESH AIR INLETS SHALL COMPLY WITH THE FOLLOWING:
A) HAVE CONTROLLABLE AND SECURE OPENINGS.
B) OPENINGS SHALL BE SCREENED OR PROTECTED TO PREVENT
ENTRY OF INSECTS, LEAVES, OR OTHER MATERIALS.
C) BE SLEEVED OR DESIGNED SO AS NOT TO COMPROMISE THE
THERMAL PROPERTIES OF THE WALL OR WINDOW IN WHICH THEY
ARE PLACED.
C) PROVIDE A MINIMUM OF FOUR SQUARE INCHES OF NET FREE
AREA OF OPENING FOR EACH 10 CFM OF OUTDOOR AIR REQUIRED IN
IRC TABLE M1507.3.3(1), IMC TABLE 403.8.1.
D) EACH OCCUPIABLE SPACE SHALL HAVE A MINIMUM OF ONE
OPENING WITH FOUR SQUARE INCHES OF NET FREE OPENING AREA.
RESUB
Jun 15 2020
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
Project Client O
Marne &Simon Evans
20020 83rd Ave. W.
Edmonds, WA 98026
Leve11 &Basement
Lighting Plan /
Utility Notes
7543 REGISTERE
ARCHITECT
G�'� '
CARL J. COLSON
S ATE OF WASHINGTO
ISSUED FOR PERMIT 1-21-2020
Document Set Type:
Revision Schedule
Rev.
# Date Description
1 6-15-2020 Add Window/ Permit Revisions
DRAWING USE NOTIFICATION
This set of drawings is being issued as a Progress or Permit Set of Drawings
and is subject to change and adding of additional information and
drawings as required by review of the Building Department in the
jurisdiction where this project is located.
DO NOT USE THIS DRAWING FOR CONSTRUCTION UNLESS THIS
DRAWING HAS A BUILDING DEPARTMENT "APPROVED" STAMP
APPLIED BY THE BUILDING DEPARTMENT UPON COMPLETION OF
THE PERMIT REVIEW PROCESS.
Do not use this drawing for Bidding or Estimating Purposes unless
authorized by Client. During Construction Phase, the Clients General
Contractor (Builder) or Developer shall be responsible for ensuring that all
Construction Personnel of the General Contractor and all Subcontractors
are supplied with all A�provecl and most current documents.
ARCHITECTURAL COPYRIGHT
This sheet of drawings may not be reproduced in any form without prior
approval of Carl J. Colson -Architect PLLC.
These document, the ideas, and designs incorporated herein as an
instrument of service shall remain the property of Carl J. Colson -Architect
PLLC and are solely for the use on this project only. These files, drawings,
ideas, or designs may not be tramsmitted electronically without express
permission of Architect. They are not be used by the client or any other
party or entity on other projects, in whole or part, or as an extension to this
project except by agreement in writing with appropriate financial
compensation to Carl J. Colson -Architect PLLC.
Copyright Carl J. Colson -PLLC, 2019. All rights reserved.
Project Number
Sheet Issue Date �
04/22/13 �
Drawn By
Author Level 1 &Basement Lighting Plan /Utility
Scale Notes
As indicated Sheet PlotDat�l14/2020 7:43:00 PM
www.CarlColsonArchitect.com
Carl J. Colson -Architect
PLLC
23623 20th Ave. W
Bothell, WA 98021
425-806-3703
��
��
wwwCarlColsonArchitect.com
��� — — — — �
I �
III
I
Commercial &Residential
III
I
III
Architecture
11
ELECTRICAL FIXTURE LEGEND
�
Evans Residence
11
L� I III � MONOXIDE DETEECTOR
I • 4��
I I D �
— — — — — — — — — — — — — — — _
�
I
SCMD
SMOKE DETECTOR
�
- -
�'
Project Address
SMOKE DETECTOR ��
— — — — �_
CLOSET LIGHTING
I
-_
_ i'�� I I
- -+��
III
I
��
SD
r RECESSED LIGHT FIXTURE
� 4"DIAMETER
20018 83r Ave. W.,
11 I INSTALLPHILLIPSSLIMSTYLE5"
hi
���
III
4"
RECESSED LIGHT FIXTURE
Edmonds WA 98026
DIAMETER LED LIGHTING WI2700•K
4"4„
III
I �I DAMP LOCATION 5" DIAMETER
�
--------
R R
�
I
4"
�
rd
/Lot
/
RECESSED LIGHT FIXTURE
�(r
New SFR at 20018 83 Ave. W 1 of
I Bedroom #1
I
FM I �
I
DAMP LOCATION 4" DIAMETER
I) =CI
PLN20180037
I ;
O O
I I ',
I I
a
FIXTURE
r
City of Edmonds Permit #: BLD2020-0250
�
OPEN TO LIVING ROOM BELOW i
III
R 5" DIAMETERIGHT
�� li�
i
y5-.�� RECESSED ADJUSTABLE LIGHT FIXTURE
PrO�eCt Client ' -
� �
�
I
��� R r 5"DIAMETER -DIRECTIONAL FOR ART
Marne &Simon Evans
4 � 4
I � \�� �
I I
5„ D DISPLAY
20020 83rd Ave. W.
I I �- ____ -�� �
�`�
i
III
PENDANT LIGHT FIXTURE @ENTRY PORCH &
��� KITCHEN ISLAND.
P
EdmOndS WA 98026
�
Ji
III
MIN. 34"ABOVE ISLAND
I
+J�
III
`� S-1 /SEMI -FLUSH LIGHT FIXTURE
Sheet Title
DIMMER @LIGHTS @MIRROR
I 11 TimerQSwitch R
`�
\1� I �
I I �
SF
�� FIXTUREM012TDED LIGHT
Level 2 Li htin 8�
g g
I
EXH.QFAN � �
4" 4"
I ROUTER &COMP. � — — — —
— — —
�
OM
� <� �'
- I �� i GFI
1
R CONNECTIONS IN
CLOSET. COORD.
��
4 � WI OWNER
12" DIA.
CEILING MOUNTED LIGHT
FIXTURE. SIZE SELECTED BY
Outlet Plan
�
11 � �� �
I
CM OWNER
�
O
SCMD 4" 4" 4"
R
I
� LIGHT FIOXTURED EXTERIOR
_
---
_
4" ` �` R R
WALL MOUNTED INTERIOR LIGHT
SCM R
�� �� � �-------�'��-_------'O
I
FIXTURE
��
7543
I 4��
�
y� DIMMER II
SWITCH FOR LIGHT ON FAN FIXTURE i
I I
�� WALL MOUNTED INTERIOR SCONCE
REGISTERE
�l �
�
� � �
�
I
� 700 LUMENS
ARCHITECT
4 - 4
� R) R � / � R
(H) `� `� i
�
EXHAUST FAN
/"�
��
�� �
�`,,
,�
0
� Bedroom #2 ,, —
' �
j
4�� �� O 4��
R �' R
� O
I I
I
Timer @Switch EXHAUST FAN w/
--
CARL J. COLSON
��'
I
O O �-' I
-- L ETLI HTIN
� COS G G
THIS LIGHT � �
�R � �O O �
I
EXH. FAN TIMER@SWITCH
SATE OF WASHINGTO
I INSTALL PHILLIPS SLIM �
I � � �
I O O STYLE 5"DIAMETER LED I i
CONTROLLED
' �� ` � �
4 FROM BELOW I NlaSter BedrOOm �
ii li
I
I
ELECTRICAL OUTLET
�
I
LIGHTING WI2700•K
ISSUED FOR PERMIT 1-21-2020
FM
4 �� 4 i
R R
O___
i I
� � SMOKE �
� � �
I
� 240 V OUTLET
� 4�� i
_- �__�
� -- � �
SMOKE �� �\ �-
'�
4� � DETECTOR i
� „ � ,_ _, ,___-__, ��
i 4 - � 4 - � 4
R �� � i R R �
� � �
I
`I -I' 240
WEATHER PROOF
� ELECTRICAL OUTLET
Document Set Type:
-
SD DETECTOR � � _ , - - �
� �
i-i uVP
R VI I n I7 I
e S 0 SC edu e
— — �—
LIGHT SWITCH
I
------�--
�
I
��
LED UNDER CABINET LIGHTING
,�!�
Rev.
#
Date
Description
— — —
4��
_ I � _ _ _
-------
,I R �
I
J
—J
L.E.D. LINEAR SURFACE
MOUNTED LIGHT
-------
I sF �
SF I
T
1
6-15-2020
Add Window /Permit Revisions
I �` i
TWO BATH OOM � , , L
SCONCESwIDIMMER �----------
700 LUMENS EACH
I I I
�
I
�� CEILING FANW/LIGHT
� FIXTURE
I ALIGN SKYLIGHT w/
I I
�1,
O O
LIGHT FIXTURES IN
i
L_IJ
MASTER BATHROOM \
it
i _ �
GFI � I `
� ��
I
ELECTRICAL LAYOUT
ALL LIGHT FIXTURE TYPES &LOCATIONS, SWITCH
1) PROVIDE AND INSTALL LOCALLY CERTIFIED SMOKE
DETECTORS AS REQUIRED BY THE NATIONAL FIRE PROTECTION
ASSOCIATION (NFPA) AND MEETING THE REQUIREMENTS OF ALL
DRAWING USE NOTIFICATION
— — �
SKYLIGHT I
I
--
�
I R � �R � R
� I-�'-'� �I
LOCATIONS, AND WIRING CONNECTIONS ARE
SCHEMATIC ONLY. ELECTRICIAN SHALL
COORDINATE PURCHASE OF ITEMS, LOCATIONS
GOVERNING CODES. SMOKE DETECTORS SHALL BE DIRECT
WIRED, 110 VOLT INTERCONNECTED WITH A BATTERY BACKUP.
This set of drawings is being issued as a Progress or Permit Set of Drawings
and is subject to change and adding of additional information and
4 � _ �-
4" ' - - �� - 4' - - - 4'
I
AND LAYOUT WITH OWNER PRIOR TO
2) PROVIDE AND INSTALL GROUND FAULT CIRCUIT
drawings as required by review of the Building Department in the
Timer t� Switch 'Master �
INSTALLATION.
INTERRUPTERS (GFI) AS REQUIRED BY THE NATIONAL ELECTRIC
jurisdiction where this project is located.
_ I
EXH.�FAN Bath � I
PHONE, CABLE, AND DATA LINE LAYOUT
CODE (NEC) AND MEETING THE REQUIREMENTS OF ALL
GOVERNING CODES.
DO NOT USE THIS DRAWING FOR CONSTRUCTION UNLESS THIS
I
i I
CONTRACTOR SHALL COORDINATE LOCATIONS OF
DRAWING HAS A BUILDING DEPARTMENT "APPROVED" STAMP
I
�
� I I
LI J
ALL PHONE OUTLETS, CABLE N OUTLETS, AND
CABLE OUTLETS FOR COMPUTERS WITH OWNER •
3) UNLESS OTHERWISE INDICATED, INSTALL SWITCHES AND
RECEPTACLES AT THE FOLLOWING HEIGHTS ABOVE FINISH
APPLIED BY THE BUILDING DEPARTMENT UPON COMPLETION OF
THE PERMIT REVIEW PROCESS.
-
_�
I R I
TYPICAL FOR ALL LEVELS
FLOOR:
Do not use this drawing for Bidding or Estimating Purposes unless
R I �
4"
4"
I
LANDSCAPE LIGHTING
SWITCHES 42"
OUTLETS 16"
authorized b Client. Durin Construction Phase, the Clients General
y g
----------
— — — — — �
LOW VOLTAGE LANDSCAPE LIGHTING IS TO BE
TELEPHONE 16"
Contractor (Builder) or Developer shall be responsible for ensuring that all
L
USED FOR THIS PROJECT, ELECTRICIAN SHALL
TELEVISION 16"
Construction Personnel of the General Contractor and all Subcontractors
—
�� ��
COORDINATE LOCATIONS &TYPES OF ALL
LANDSCAPE LIGHTING WI OWNER
are supplied with all Atitiroved and most current documents.
ARCHITECTURAL COPYRIGHT
�� J� ILL_ J�
This sheet of drawings may not be reproduced in any form without prior
approval of Carl J. Colson -Architect PLLC.
Level 2 Lighting Plan
These document, the ideas, and designs incorporated herein as an
instrument of service shall remain the property of Carl J. Colson -Architect
1 1 /4" = 1 �- O ��
PLLC and are solely for the use on this project only. These files, drawings,
ideas, or designs may not be tramsmitted electronically without express
permission of Architect. They are not be used by the client or any other
party or entity on other projects, in whole or part, or as an extension to this
project except by agreement in writing with appropriate financial
compensation to Carl J. Colson -Architect PLLC.
Copyright Carl J. Colson -PLLC, 2019. All rights reserved. O
Project Number
�
Sheet Issue Date
09/12/18
�
RES U B
Drawn By
Jun 15 2020
Author
Level2 Lighting &Outlet Plan
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
Sheet Plot Dat�/14/2020 7:43:21 PM
Scale
1 /4" = 1'-0"
www.CarlColsonArchitect.com
LINE OF 25' MAX
BUILDING HEIGHT
ELEV. 436.18'
LINE OF PROPOSED
BUILDING HEIGHT
ELEV. 435.55'
PORCH GUARDRAIL
SEE DETAIL ON SHE
FOR 36" HIGH GUAR
LINE OF AVERAGE
GRADE: EL. 411.18'
WRAPPED BEAM DE
SEE DETAIL ON SHE
FOR WRAPPED BEA
DETAIL
PREPRIMING AND PAINTING OF EXTERIOR WOOD SURFACES
ANY NATURAL WOOD SIDING OR WOOD TRIM � EXTERIOR SHALL BE PRE- sKYLIGHT- sEE RooF PLAN
PRIMED (BY PAINTER OR SUPPLIER) AT ALL SIDES (BEFORE INSTALLATION) - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
AND SHALL BE PAINTED W/ EXTERIOR PAINT AS SELECTED BY OWNER.
ALL EXTERIOR WOOD TRIM SHALL HAVE SMOOTH SURFACE //
ROOF RAKE NOTE: THE
ARCHITECTURAL SOFTWARE
SHOWS THE ELEVATION
DRAWINGS WITH A DIFFERENT
RAKE PROFILE THAN DETAIL
BELOW. CONSTRUCT RAKE PER
DETAIL BELOW
ROOF SLOPE &OVERHANG -
PER ROOF PLAN
ROOF SHINGLES TO
OVERHANG 3/4". INSTALL 26
GAUGE METAL DRIP
FLASHING TO DRAIN INTO
GUTTER
FASCIA: PRIMED (ALL SIDES)
& PAINTED 2 x 8 CEDAR TRIM
W/SMOOTH FINISH
ALL RAKE BOARDS SHALL
HAVE ATWO-CUT PLUMB
VERTICAL AND HORIZONTAL
SURFACE, PER DETAIL
MITER JOINT
ALL RAKE BOARDS AND
FASCIA BOARDS SHALL BE
MITERED
Roof Rake Detail
PTD. 26 GAUGE
METAL DRIP
FLASHING
1 X 3 PRIMED &
PTD. CEDAR TRIM
2 X 8 PRIMED (ALL
SIDES) & PTD.
CEDAR RAKE
BOARD
NOTES TO BUILDING ELEVATIONS
NOTE: THE TERM "BUILDER" REFERS TO THE DEVELOPER WHOSE
RESPONSIBILITY INCLUDES THAT OF GENERAL CONTRACTOR.
THESE NOTES ARE FOR THE EXTERIOR BUILDING ELEVATION
DRAWINGS AT ALL UNITS.. ALL NOTES MAY NOT APPLY TO EACH
UNIT.
THESE ELEVATION NOTES ARE FOR ALL SINGLE-FAMILY HOUSES
Upper Top Plate DESIGNED BY ARCHITECT. SOME NOTES MAY REFER TO
18.58 � CONSTRUCTION TYPES OR ITEMS NOT FOUND IN THIS PROJECT.
PAINTED METAL INSULATED OVERHEAD CARRIAGE STYLE
GARAGE DOOR (AUTOMATIC OPENER) W/VISION PANELS AS
SHOWN. SELECTION BY OWNER.
PAINTED WOOD TRIM AT HEAD OF GARAGE DOOR. 5/4x10
HEAD PIECE WITH WOOD TRIM PROFILE MOLDING AT TOP AND
BOTTOM AS SHOWN (SELECTION BY BUILDER). SEE WINDOW
SCHEDULE ABOUT METAL HEAD FLASHING REQUIREMENTS.
3). WRAPPED PORCH OR DECK SUPPORT COLUMN. REFER TO
Level 2 ENTRY PORCH COLUMN DETAIL FOR INFORMATION. ALL POSTS
10.49 SHALL BE FLASHED TO PREVENT WATER INTRUSION INTO
Level 1 Top Plate COLUMN ENCLOSURE.
9.09 `�_
4.) ASPHALT ROOF SHINGLES. SEE SHEET A-4.1 FOR
INFORMATION.
5.) SYNTHETIC DECKING AT ENTRY PORCH. SEE FLOOR PLAN
FOR DIMENSIONS & LOCATIONS OF STEPS TO ENTRY WALK &
DRIVEWAY.
6.) PAINTED CEDAR (OR SYNTHETIC BOARD) TRIM BOARD @
EDGE OF DECK
PRIMED &PAINTED CEDAR SIDING OR HARDIEBOARD SIDING
LEVEL 1 FIN. FLR. OR HARDIE SHINGLE SIDING. SEE BUILDING SECTIONS FOR
EL. 413.5' NOTES ON WALL ASSEMBLY.
Level 1
0.00 � INSULATED VINYL WINDOWS - REFER TO FLOOR PLAN &
T.O.F.W. WINDOW SCHEDULE FOR TYPES.
-1.18
_ _ _ _ _ 9.) PRIMED &PAINTED CEDAR TRIM AROUND WINDOWS &
DOORS. SEE DETAILS ON SHEET A-5.1 FOR TRIM INFORMATION.
10. iX CEDAR BOARD WRAP AT ROOF SUPPORT BEAM AT
PORCH.
11. PAINTED 5/4 x 6 PRIMED &PAINTED CEDAR CORNER BOARDS
BASEMENT FIN. FLR. 12. 2x PRIMED AND PAINTED RAKE BOARDS (AT WALL SURFACE
EL. 404.23' BEHIND ROOF OVERHANG) W/PRIMED &PAINTED CEDAR 1X4
TRIM
� Basement
_g 27 1� ELECTRIC METER -INSTALL PER ELECT. CO. REQUIREMENTS.
14. GAS METER -INSTALL PER GAS CO. REQUIREMENTS.
15. PAINTED METAL INSULATED DOOR. STYLE SELECTION BY
III III III III III III III III III III III III III III III III III III III- OWNER.
East Elevation 16. PORCH ROOF FRAMING: PREMANUFACTUREDBOOF
7 TRUSSES @ 24" O.C.. REFER TO SECTION DRAWINGS FOR PORCH
� 1 / ♦ /^ �� _ ♦ �-O�� CEILING INFORMATION
�� I �F I 17. STAIRS FROM PORCH TO FINISH GRADE. CONTRACTOR TO
COORD. NUMBER OF TREADS &RISERS W/ELEVATION OF FINISH
GRADE. TREADS &RISERS SHALL BE SYNTHETIC "TREX"DECKING
LINE OF 25' MAX MATERIAL. ALL FRAMING &SUPPORT POSTS (IN CONCRETE
BUILDING HEIGHT FOOTINGS) SHALL BE PRESSURE TREATED WOOD PER
ELEV. 436.18' STRUCTURAL DRAWINGS.
---------------------------------------- - 1�COVEREDDECKW/WATERPROOF WALKING SURFACE
MEMBRANE -SEE LEVEL 2 FLOOR PLAN FOR NOTES
LINE OF PROPOSED 19. PRIMED AND PAINTED CEDAR GUARDRAIL, CAP, AND POSTS.
BUILDING HEIGHT GUARDRAIL SHALL BE 36"HIGH ABOVE DECK. SEE DETAIL ON
ELEV. 435.55' SHEET A-4 4
III III III
� � � � i
� � � i
i i i �
)ER NOTE: OPEN TO
FOUNDATION WALL IS DECK BEYOND_
PED. REFER TO STRUCTURAL
VINGS AND COORDINATE
PED WALL wl GRADING PLAN EXTERIOR VENT
FOR VENTED
FIREPLACE
unvnvu r�rs�n
OPEN TO PATIO
-T
III III
. 1 tftYUNU i �
I -�� �
�. �� ��
T 131' 5' - 0"- '�� .1 �� . 7� - 9��
POSSIBLE RETAINING WALL
@ THIS AREA. COORDINATE
_�_ �
w/SITE GRADING PLAN
��
-III III III III �T � I � � I � � I � 1-f I � � I �T
South Elevation
SEE EAST ELEVATION FOR
TYPICAL EXTERIOR NOTES
Upper To�Plate
18.58
�
o
_
�
�
o
v
W
2
J
Q
M
�
Z
o
2
c�
- Level2
�
"'
x
10.49
o
z
Level 1 To�Plate
o
9.09 -
o
m
�
M
�
�
iG
�
N
2
r
�
o
v
N
N
�° Levell
_"' 0.00
T.O.F.W.
-1.18
LINE OF AVERAGE
GRADE: EL. 411.18'
SLOPING GRADE &
LANDSCAPE BLOCK
RETAINING WALLS � THIS
AREA. REFER TO CIVIL
T ENGINEER FOR SITE
°° GRADING PLANS
Basement
9 27
�T � �
II III I
2� PAINTED METAL FLUE VENT FOR GAS FIREPLACE.
COORDINATE COLOR OF PAINT W/OWNER
21. CHIMNEY FLUE ENCLOSURE: MANUFACTURED STONE
VENEER W/PRECAST STONE OR METAL CAP OVER CEMENT
BACKER BOARD OVER WATERPROOF MEMBRANE (ICE -WATER
SHIELD) OVER WEATHER RESISTIVE BARRIER OVER PRESSURE
TREATED PLYWOOD OVER SCHEDULED EXTERIOR WALL. STONE
SELECTION BY OWNER. SEE ROOF PLAN FOR ROOF CRICKET AND
ADDITIONAL INFORMATION
2� LANDSCAPE RETAINING WALLS -SEE GRADING PLAN FOR
LOCATION &TYPE
23. GAS FIREPLACE AT DINING DECK. SEE LEVEL 1 FLOOR PLAN
AND SOUTH BUILDING SECTION FOR ADDITIONAL INFORMATION
2� SYNTHETIC STONE VENEER (SELECTION BY OWNER) OVER
CEMENT BACKERBOARD OVER WATERPROOF MEMBRANE OVER
PRESSURE TREATED PLYWOOD SHEATHING OVER 2x6 STUD
WALL. TOP OF STONE VENEER SHALL HAVE PRIMED AND PAINTED
CEDAR COPING w/METAL FLASHING @TOP EDGE.
RESUB
Jun 15 2020
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
Carl J. Colson -Architect
PLLC
23623 20th Ave. W
Bothell, WA 98021
425-806-3703
wwwCarlColsonArchitect. com
Commercial &Residential
Architecture
Evans Residence
,,_ ��,
Project Address
20018 83rd Ave. W.,
Edmonds, WA 98026
New SFR at 20018 83rd Ave. W (Lot 1 of
PLN20180037)
City of Edmonds Permit #: BLD2020-0250
���
Project Client
Marne &Simon Evans
20020 83rd Ave. W.
Edmonds, WA 98026
Sheet Title
South &East
Exterior Elevations
7543 REGISTERE
ARCHITECT
G,,."� '
CARL J. COLSON
S ATE OF WASHINGTO
ISSUED FOR PERMIT 1-21-2020
Document Set Type:
Revision Schedule
Rev.
# Date Description
1 6-15-2020 Add Window /Permit Revisions
DRAWING USE NOTIFICATION
This set of drawings is being issued as a Progress or Permit Set of Drawings
and is subject to change and adding of additional information and
drawings as required by review of the Building Department in the
jurisdiction where this project is located.
DO NOT USE THIS DRAWING FOR CONSTRUCTION UNLESS THIS
DRAWING HAS A BUILDING DEPARTMENT "APPROVED" STAMP
APPLIED BY THE BUILDING DEPARTMENT UPON COMPLETION OF
THE PERMIT REVIEW PROCESS.
Do not use this drawing for Bidding or Estimating Purposes unless
authorized by Client. During Construction Phase, the Clients General
Contractor (Builder) or Developer shall be responsible for ensuring that all
Construction Personnel of the General Contractor and all Subcontractors
are supplied with all Atitiroved and most current documents.
ARCHITECTURAL COPYRIGHT
This sheet of drawings may not be reproduced in any form without prior
approval of Carl J. Colson -Architect PLLC.
These document, the ideas, and designs incorporated herein as an
instrument of service shall remain the property of Carl J. Colson -Architect
PLLC and are solely for the use on this project only. These files, drawings,
ideas, or designs may not be tramsmitted electronically without express
permission of Architect. They are not be used by the client or any other
party or entity on other projects, in whole or part, or as an extension to this
project except by agreement in writing with appropriate financial
compensation to Carl J. Colson -Architect PLLC.
Copyright Carl J. Colson -PLLC, 2019. All rights reserved.
Project Number
Sheet Issue Date
�
01 /14/14
�
Drawn By
Author
South &East Exterior Elevations
Scale
As indicated
Sheet Plot Dat�/14/2020 7:43:42 PM
www.CarlColsonArchitect.com
NOTES TO BUILDING ELEVATIONS
LINE OF 25' MAX
BUILDING HEIGHT
ELEV. 436.18' �
LINE OF PROPOSED
BUILDING HEIGHT
ELEV. 435.55'
LINE OF AVERAGE
GRADE: EL. 411.18'
LANDSCAPE
BLOCK RETAINING
WALL BEYOND.
SEE CIVIL SITE
GRADING PLANS
PREPRIMING AND PAINTING OF EXTERIOR WOOD SURFACES
ANY NATURAL WOOD SIDING OR WOOD TRIM @EXTERIOR SHALL BE PRE -
PRIMED (BY PAINTER OR SUPPLIER) AT ALL SIDES (BEFORE
INSTALLATION) AND SHALL BE PAINTED W/ EXTERIOR PAINT AS SELECTED
BY OWNER.
ALL EXTERIOR WOOD TRIM SHALL HAVE SMOOTH SURFACE
ROOF RAKE NOTE: THE
ARCHITECTURAL SOFTWARE
SHOWS THE ELEVATION
DRAWINGS WITH A DIFFERENT
RAKE PROFILE THAN DETAIL
BELOW. CONSTRUCT RAKE PER
DETAIL BELOW
ROOF SLOPE & OVERF
PER ROOF PLAN
ROOF SHINGLES TO
OVERHANG 3/4". INST/
GAUGE METAL DRIP
FLASHING TO DRAIN IP
GUTTER
FASCIA: PRIMED (ALL
& PAINTED 2 x 8 CEDA
W/SMOOTH FINISH
ALL RAKE BOARDS SH
HAVE ATWO-CUT PLU..._
VERTICAL AND HORIZONTAL
SURFACE, PER DETAIL
MITER JOINT
ALL RAKE BOARDS AND
FASCIA BOARDS SHALL BE
MITERED
Roof Rake Detail
PTD. 26 GAUGE
METAL DRIP
FLASHING
1 X 3 PRIMED &
PTD. CEDAR TRIM
2 X 8 PRIMED (ALL
SIDES) & PTD.
CEDAR RAKE
BOARD
_ �
c� _
w �
= w
z=_
s �
J_ Z
� �
CO J
w �
m
m o
Q w
N
o
0
r
o �
N N
� � LINE OF 25' MAX BUILDING HEIGHT
r`
imi
_ _ �t �
■ � � �
� � � �
■ � � �
� � � �
� � _ � �
_ry � '� r r Y � �� r " � r
Upper To Pp late
18.58
Level 2
- 10.49
Level 1 To Pp late
9.09
r
��� ��� �
��� ���
1
24
LEVEL 1 FIN. FLR.
EL. 413.5' N
/` _ Level i T
0.00
III ��� ��� �� � � ���� � ���� � ���� � ���� � ���� � ��� � ��� I I � ���� � ��� � �� �� � �� �� � ��� � ��
��� ��� ��� III �� ��� ��� ��� ��� ��� ��� ��� ��� III ��� ��� ��� ��� ��� III III III III III III III �� ���_
North Elevation
/ 0
West Elevation
ri
SEE SOUTH &NORTH ELEVATION
FOR TYPICAL EXTERIOR NOTES
T.O. F. W .
-1.18
I INIF nF �ti� nnou
LINE OF AVERAGE
GRADE: EL. 411.18'
NOTE: THE TERM "BUILDER" REFERS TO THE DEVELOPER WHOSE
RESPONSIBILITY INCLUDES THAT OF GENERAL CONTRACTOR.
THESE NOTES ARE FOR THE EXTERIOR BUILDING ELEVATION DRAWINGS
AT ALL UNITS.. ALL NOTES MAY NOT APPLY TO EACH UNIT.
THESE ELEVATION NOTES ARE FOR ALL SINGLE-FAMILY HOUSES
DESIGNED BY ARCHITECT. SOME NOTES MAY REFER TO CONSTRUCTION
TYPES OR ITEMS NOT FOUND IN THIS PROJECT.
PAINTED METAL INSULATED OVERHEAD CARRIAGE STYLE GARAGE
DOOR (AUTOMATIC OPENER) W/VISION PANELS AS SHOWN. SELECTION
BY OWNER.
PAINTED WOOD TRIM AT HEAD OF GARAGE DOOR. 5/4x10 HEAD PIECE
WITH WOOD TRIM PROFILE MOLDING AT TOP AND BOTTOM AS SHOWN
(SELECTION BY BUILDER). SEE WINDOW SCHEDULE ABOUT METAL HEAD
FLASHING REQUIREMENTS.
3). WRAPPED PORCH OR DECK SUPPORT COLUMN. REFER TO ENTRY
PORCH COLUMN DETAIL FOR INFORMATION. ALL POSTS SHALL BE
FLASHED TO PREVENT WATER INTRUSION INTO COLUMN ENCLOSURE.
4.) ASPHALT ROOF SHINGLES. SEE SHEET A-4.1 FOR INFORMATION.
5.) SYNTHETIC DECKING AT ENTRY PORCH. SEE FLOOR PLAN FOR
DIMENSIONS &LOCATIONS OF STEPS TO ENTRY WALK &DRIVEWAY.
6.) PAINTED CEDAR (OR SYNTHETIC BOARD) TRIM BOARD @ EDGE OF
DECK
PRIMED &PAINTED CEDAR SIDING OR HARDIEBOARD SIDING. SEE
BUILDING SECTIONS FOR NOTES ON WALL ASSEMBLY.
INSULATED VINYL WINDOWS - REFER TO FLOOR PLAN &WINDOW
SCHEDULE FOR TYPES.
9.) PRIMED &PAINTED CEDAR TRIM AROUND WINDOWS &DOORS. SEE
DETAILS ON SHEET A-5.1 FOR TRIM INFORMATION.
1� 1X CEDAR BOARD WRAP AT ROOF SUPPORT BEAM AT PORCH.
11. PAINTED 5/4 x 6 PRIMED &PAINTED CEDAR CORNER BOARDS
1� 2x PRIMED AND PAINTED RAKE BOARDS (AT WALL SURFACE BEHIND
ROOF OVERHANG) W/PRIMED &PAINTED CEDAR iX4 TRIM
13. ELECTRIC METER -INSTALL PER ELECT. CO. REQUIREMENTS.
14. GAS METER -INSTALL PER GAS CO. REQUIREMENTS.
15. PAINTED METAL INSULATED DOOR. STYLE SELECTION BY OWNER.
1� PORCH ROOF FRAMING: PREMANUFACTURED ROOF TRUSSES @ 24"
O.C.. REFER TO SECTION DRAWINGS FOR PORCH CEILING INFORMATION
17. STAIRS FROM PORCH TO FINISH GRADE. CONTRACTOR TO COORD.
NUMBER OF TREADS &RISERS W/ ELEVATION OF FINISH GRADE. TREADS
& RISERS SHALL BE SYNTHETIC "TREX" DECKING MATERIAL. ALL FRAMING
& SUPPORT POSTS (IN CONCRETE FOOTINGS) SHALL BE PRESSURE
TREATED WOOD PER STRUCTURAL DRAWINGS.
18. COVERED DECK W/ WATERPROOF WALKING SURFACE MEMBRANE -
SEE LEVEL 2 FLOOR PLAN FOR NOTES
1� PRIMED AND PAINTED CEDAR GUARDRAIL, CAP, AND POSTS.
GUARDRAIL SHALL BE 36" HIGH ABOVE DECK
20. PAINTED METAL FLUE VENT FOR GAS FIREPLACE. COORDINATE
COLOR OF PAINT W/OWNER
2� CHIMNEY FLUE ENCLOSURE: MANUFACTURED STONE VENEER W/
PRECAST STONE OR METAL CAP OVER CEMENT BACKER BOARD OVER
WATERPROOF MEMBRANE (ICE -WATER SHIELD) OVER WEATHER
RESISTIVE BARRIER OVER SCHEDULED EXTERIOR WALL. STONE
SELECTION BY OWNER. SEE ROOF PLAN FOR ROOF CRICKET AND
ADDITIONAL INFORMATION
22. LANDSCAPE RETAINING WALLS -SEE GRADING PLAN FOR LOCATION
& TYPE
2� GAS FIREPLACE AT DINING DECK. SEE LEVEL 1 FLOOR PLAN AND
SOUTH BUILDING SECTION FOR ADDITIONAL INFORMATION
24. SYNTHETIC STONE VENEER (SELECTION BY OWNER) OVER CEMENT
BACKERBOARD OVER WATERPROOF MEMBRANE OVER PRESSURE
TREATED PLYWOOD SHEATHING OVER 2x6 STUD WALL. TOP OF STONE
VENEER SHALL HAVE PRIMED AND PAINTED CEDAR COPING w/METAL
FLASHING @TOP EDGE.
RESUB
Jun 15 2020
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
Carl J. Colson -Architect
PLLC
23623 20th Ave. W
Bothell, WA 98021
425-806-3703
wwwCarlColsonArchitect. com
Commercial &Residential
Architecture
Evans Residence
✓ Y✓ _Y✓ Y✓ Y✓ Y✓ Y✓ Y✓" Y✓" Y✓" ✓
Project Address
20018 83rd Ave. W.,
Edmonds, WA 98026
New SFR at 20018 83rd Ave. W (Lot 1 of
PLN20180037)
City of Edmonds Permit #: BLD2020-0250
Project Client
Marne &Simon Evans
20020 83rd Ave. W.
Edmonds, WA 98026
Sheet Title
North &West
Exterior Elevations
7543 REGISTERE
ARCHITECT
�� '
CARL J. COLSON
S ATE OF WASHINGTO
ISSUED FOR PERMIT 1-21-2020
Document Set Type:
Revision Schedule
Rev.
# Date Description
1 6-15-2020 Add Window /Permit Revisions
DRAWING USE NOTIFICATION
This set of drawings is being issued as a Progress or Permit Set of Drawings
and is subject to change and adding of additional information and
drawings as required by review of the Building Department in the
jurisdiction where this project is located.
DO NOT USE THIS DRAWING FOR CONSTRUCTION UNLESS THIS
DRAWING HAS A BUILDING DEPARTMENT "APPROVED" STAMP
APPLIED BY THE BUILDING DEPARTMENT UPON COMPLETION OF
THE PERMIT REVIEW PROCESS.
Do not use this drawing for Bidding or Estimating Purposes unless
authorized by Client. During Construction Phase, the Clients General
Contractor (Builder) or Developer shall be responsible for ensuring that all
Construction Personnel of the General Contractor and all Subcontractors
are supplied with all Atitiroved and most current documents.
ARCHITECTURAL COPYRIGHT
This sheet of drawings may not be reproduced in any form without prior
approval of Carl J. Colson -Architect PLLC.
These document, the ideas, and designs incorporated herein as an
instrument of service shall remain the property of Carl J. Colson -Architect
PLLC and are solely for the use on this project only. These files, drawings,
ideas, or designs may not be tramsmitted electronically without express
permission of Architect. They are not be used by the client or any other
party or entity on other projects, in whole or part, or as an extension to this
project except by agreement in writing with appropriate financial
compensation to Carl J. Colson -Architect PLLC.
Copyright Carl J. Colson -PLLC, 2019. All rights reserved.
Project Number
Sheet Issue Date �
07/05/18 �
Drawn By
Author North &West Exterior Elevations
Scale
As indicated Sheet Plot Dat�/14/2020 7:44:19 PM
www.CarlColsonArchitect.com
ROOF RIDGE VENTS
SEE ROOF PLAN FOR ALL RIDGE VENT
LOCATIONS &ROOF VENT CALCULATIONS
PAINTED 2 x 8 CEDAR FASCIA BOARD.
PRE -PRIMED @ALL SIDES (TYP)
PORCH ROOF/CEILING FRAMING:
SEE STRUCTURAL DRAWINGS FOR
ALL FRAMING INFORMATION.
FRAMING SUB SHALL COORDINATE
TOP OF BEAM ELEVATION (IF
NECESSARY) SO THAT PORCH
FASCIA ALIGNS w/ADJACENT ROOF
FASCIA"S
ALIGN FASCIA'S
PRIMED AND PAINTED SMOOTH
PLYWOOD SHEATHING AT AREA OF
EXPOSED EAVES (TYP)
CEILING BOX BEAM WRAPPED WI PRIMED
AND PAINTED 1 x CEDAR WOOD TRIM). SEE
STRUCT. DRAWINGS FOR BEAM SIZES
SEE SHEET A-3.1 FOR PORCH
COLUMNS DETAIL
WOOD FRAMED DECK (W/SYNTHETIC DECKING
OVER PRESSURE TREATED WOOD FRAMING) @
ENTRY PORCH - SELECTION BY OWNER.
PRESSURE TREATED BOARDS @DECK FRAMING
E t Po c
,
�'
,'
'
,'
APPLY LIQUID PRESSURE TREATED WOOD
SEALANT @ALL PRESSURE TREATED BOARDS
THAT ARE CUT OR RIPPED. TREAT AT ALL
EXPOSED ENDS &SIDES (TYP AT ALL AREAS)
ROOF SLOPE &OVERHANG
SEE ROOF PLAN FOR ALL ROOF SLOPE
AND OVERHANG INFORMATION
ROOF TRUSS
PRE-ENGINEERED ROOF TRUSSES @ 24" O.C. -SEE
STRUCTURAL DRAWINGS.
TRUSS LAYOUT SHOWN IS SCHEMATIC ONLY. REFER TO
ROOF PLAN &EXTERIOR ELEVATIONS FOR ROOF DESIGN
THAT INCLUDES GABLES, HIPS, OR OVERFRAMED AREAS.
� ROOF @LIVING ROOM IS FRAMED w/
JOISTS, RATHER THAN TRUSSES. SEE
STRUCTURAL DRAWINGS FOR FRAMING
FULL HEIGHT STUDS @THIS WALL
PRIMED AND PAINTED TONGUE AND
GROOVED BOARDS CEILING AT ENTRY
AND KITCHEN PORCH.. SEE
STRUCTURAL DRAWINGS FOR PORCH
ROOF /CEILING FRAMING INFORMATION
OPEN TO BEYOND
Livin R� oom
SEE WINDOW SCHEDULE SHEET FOR
ALL INTERIOR DOOR &WINDOW TRIM
INFORMATION
� FLOOR CONSTRUCTION
SEE ASSEMBLY NOTES BELOW FOR
FLOOR CONSTRUCTION OVER
UNHEATED AREA
SEE STRUCTURAL
NOTES FOR THIS
JOIST INFORMATION
R-49 INSULATION @ATTIC
ATTIC ACESS IN MASTER CLOSET
SEE FLOOR PLAN FOR ATTIC
ACCESS HATCH LOCATION
ROOF TRUSS BEARING
ROOF TRUSS NOT TO BEAR UPON
INTERIOR WALLS (UNLESS NOTED ON
STRUCTURAL DRAWINGS)
R-38 INSULATION @ROOF
JOISTS @ LVING ROOM AREA
Bedroom #1
INTERIOR WALL
SEE WALL CONSTRUCTION ASSEMBLY
NOTES BELOW FOR INTERIOR WALL
CONSTRUCTION
DUCTWORK
NO DUCTWORK ALLOWED IN ATTIC OR
CRAWL SPACE (TYPICAL)
CEILING AT ATTIC
SEE ASSEMBLY NOTES
BELOW FOR CEILING
CONSTRUCTION
EXTERIOR WALL
SEE WALL
CONSTRUCTION
ASSEMBLY NOTES
BELOW FOR EXTERIOR
WALL CONSTRUCTION �
— FLOOR FRAMING
FRAMING IS SCHEMATIC ONLY.
SEE STRUCTURAL DRAWINGS
FOR ALL FLOOR JOIST SIZES,
SPACING, SUPPORT POSTS,
AND POST FOOTINGS
INSTALL DRAFTSTOPS INFLOOR/CEILING
ASSEMBLIES SO THAT CONCEALED SPACE
DOES NOT EXCEED 1,000 S.F.
PARALLEL CHORD WOOD FLOOR TRUSSES
@ UPPER LEVEL ONLY. (FRAMING SHOWN
IS SCHEMATIC ONLY -SEE STRUCTURAL
DRAWINGS FOR SIZE, FRAMING LAYOUT,
AND SUPPORTING BEAMS AT THIS AREA)
VENTILATED CRAWL SPACE :SEE
FOUNDATION PLAN FOR LOCATION OF
FOUNDATION VENTS
SIDE MOUNTED JOIST HANGERS ATTACHED
TO SILL PLATE PER STRUCT. DRAWINGS
STRUCTURAL BEAM '
WRAPPED W/GYP. BOARD.
SEE STRUCT. DRAWINGS
STRUCTURAL BEAM (BEYOND)
WRAPPED WI GYP. BOARD
Gara;?e
PROJECTING WALL BEYOND. SEE
FLOOR PLAN FOR LOCATION
GARAGE SLAB
4" REINFORCED CONC. SLAB (w/THICKENED
EDGES) OVER VAPOR BARRIER OVER 4"
COMPACTED GRAVEL FILL. INSTALL CRACK
CONTROL JOINTS PER GARAGE FLOOR PLAN.
SLOPE SLAB TOWARD GARAGE DOORS
TRUSS BIRD BLOCK VENTS
BIRD BLOCK VENTS @EAVES BY ROOF
ALL BIRD BLOCK VENTS SHALL HAVE
INSECT SCREEN AT ATTIC SIDE OF BLOCK
�I� '
ELEVATION OF GARAGE
SLAB VARIES
STONE VENEER @THIS AREA � �_ a 1 - � a _ �aa � � � � � � � � n �° .� , a � � � � � � a � a � �-
o 000 0 00 0 00 0 000 0 000 0 000 000�0�0 000 0 00 0 00 0 000 000 0 00 0 000 0 000 0 000 0 0 �� �� � �� �� o 0 0 0 0 0 0 0 0 0 0 �o� o 0 0 _o o _o 0 0 0
o °o° °o° °o° °o° °o° °o° °o° °o° °o° °o° °o° °o° °o° °o° `b o -.. - o - o- =.. o- 's.- c =o- c � °o- c a= :c`� `b .c `b" '� � o `b% =� `b° =� - o- - - o- °o
i I . FLOOR INSULATION . � � � °° °° °� �� =HOLD TOP OF THIS FOUNDATION WALL I I v � ° �° a
i a R-38 INSULATION @FLOORS I � I _BELOW GARAGE FLOOR SLAB. SEE LEVEL 1
iii iii i
� i OVER UNHEATED SPACES �I � I � FLOOR PLAN FOR LOCATION AND
-_
SITE RETAINING WALL BEYOND. SEE SITE �I a L — — — — — — — — — — — — — — — — — — — — � � _COORDINATE w/ STRUCTURAL DRAWINGS -
GRADING PLAN FOR LOCAi ION &MATERIAL= � L a - STRUCTURAL FRAMING— �� III � � � � � � -
° - - ��
FOUNDATION VENTS & WELLS i ,a o- - SEE STRUCTURAL DRAWINGS - a°_ -°, Q , a � a -
�� O I �
SEE EXTERIOR ELEVATION DRAWINGS & - FOR ALL FLOOR FRAMING AND - - -
FOUNDATION PLAN FOR LOCATIONS &VENT = � III III SUPPORT POSTS, FOUNDATION � I -
CALCULATIONS ON FOUNDATION PLAN SHEET— CRAWL SPACE BARRIER , , , WALLS & FOOTINGS IN CRAWL I
III III III _VAPOR BARRIER.AS SPECIFIED IN SPACE (TYPICAL) III - I I
� III III III NOTES ON THIS PAGEI EXTEND UPISiDE III III � � III III III III III � � � �
WALLS A MIN. OF 12 I I
I I CRAWL SPACE CLEARANCE CRAWL SPACE ACCESS BUILDER NOTE: THIS FOUNDATION WALL I
I I MAINTAIN 27"CLEARANCE BETWEEN SEE FLOOR PLANS FOR CRAWL &FOOTING WILL STEP DOWN I
I I BOTTOM OF SUPPORT BEAMS AND CONC. SPACE ACCESS HATCH INCREMENTALLY TO BASEMENT LEVEL I
I I SLAB IN CRAWL SPACE BEYOND. COORDINATE W/ STRUCTURAL I
I EXTENT OF BASEMENT BEYOND -SEE BASEMENT FLOOR PLAN DRAWINGS &SITE CONDITIONS I
I_ _ _ _ _ _ _
r--- ------------ ------------ ----------------------ZL�
L------------------------------------------------------------J
(� � Section Through Porch, Living Room, 8� Garage
CONSTRUCTION ASSEMBLY NOTES
WALL ASSEMBLY NOTES
SEE NOTES ABOUT MOLD, PRESSURE TREATED WOOD AND FASTENERS ON SHEET A-1.2
FIRE RATED ASSEMBLIES
REFER TO SHEET 2-1 AND NOTES BELOW FOR FIRE/OCCUPANCY SEPARATION
REQUIREMENTS BETWEEN GARAGE AND LIVING SPACE
TYPICAL EXTERIOR WALL CONSTRUCTION
HARDIE-PLANK LAP SIDING (SMOOTH FINISH AND MATCHING CAULK) W/ 6" EXPOSURE
OVER BENJAMIN OBDYKE HYDROGAP DRAINABLE HOUSEWRAP OVER 1 /2" EXT. PLYWOOD
(OR 7/16" O.S.B.). SHEATHING OVER 2x6 STUDS @ 16" O.C. W/ R-21 BATT INSULATION AND
1/2" PTD. GWB OVER MEMBRAIN SMART VAPOR RETARDER VAPOR BARRIER (OR
BENJAMIN MOORE'S SUPER SPEC LATEX VAPOR BARRIER PRIMER SEALER 260). SEE
ELEVATION DRAWINGS FOR SPECIFIED SIDING MATERIALS.
ANY NATURAL WOOD SIDING OR WOOD TRIM @EXTERIOR SHALL BE PRE -PRIMED AT ALL
SIDES (BEFORE INSTALLATION) AND PAINTED W/EXTERIOR PAINT.
SEE ELEVATION DRAWINGS FOR SPECIFIED SIDING MATERIALS.
STONE VENEER EXTERIOR WALL CONSTRUCTION
SYNTHETIC STONE VENEER (SELECTION BY OWNER) OVER CEMENT BACKERBOARD OVER
WATERPROOF MEMBRANE OVER PRESSURE TREATED PLYWOOD SHEATHING OVER 2x6
STUD WALL. TOP OF STONE VENEER SHALL HAVE PRIMED AND PAINTED CEDAR COPING
OR COPING BY STONE MANUFACTURER (OWNER SELECTION) w/METAL FLASHING @TOP
EDGE.
TYPICAL INTERIOR WALL CONSTRUCTION
1/2" PAINTED GYPSUM WALLBOARD (GWB) AT EACH SIDE OF WALL W/ 2x4 STUDS @ 16"
O.C. USE 1/2" WATER RESISTANT GYP. BD. @ALL KITCHEN, BATHROOM, AND LAUNDRY
ROOM LOCATIONS. USE WONDERBOARD (CEMENT BACKERBOARD) BACKING BEHIND
ALL TUBS, SHOWERS, AND TILE LOCATIONS
GARAGE WALL CONSTRUCTION
(SEE OCCUPANCY SEPARATION NOTES FOR WALL AND CEILING CONSTRUCTION
BETWEEN GARAGE AND LIVING AREAS)
5/8" PTD. TYPE X GYPSUM WALLBOARD (FIRETAPED) AT INTERIOR FACE OF WALL
WITH 2x4 OR 2x6 STUDS @ 16" O.C.. EXTERIOR FACE OF WALL SHALL BE PRE-
PRIMEDAND PAINTER CEDAR OR HARDIE-PLANK HORIZONTAL LAP SIDING OVER
FORTIFIBER WEATHERSMART DRAINABLE OR BENJAMIN OBDYKE HYDROGAP DRAINABLE
HOUSEWRAP OVER 1/2" EXT. PLYWOOD SHEATHING. REFER TO BUILDING ELEVATIONS
FOR LOCATION OF CULTURED STONE VENEER TO BE APPLIED IN LIEU OF WOOD SIDING.
WALL ANCHORING
UNLESS SHOWN OTHERWISE ON STRUCURAL OR FRAMING DRAWINGS, BOLT APPROVED
MUD SILL (PER SEC 2317.4 TO TOP OF CONC. WALL W/ 5/8" x 10" ANCHOR BOLTS @ 4'-0" O.C.
& 1'-0" O.C. FROM EACH SPLICE PER SEC 1806.5. PROVIDE TERMITE SHIELD AT MUDSILL
BASEMENT WALL WATERPROOFING (IF USED ON PROJECT
TUFF-N-DRI H8 WATERPROOFING MEMBRANE AT ALL BELOW GRADE BASEMENT WALLS
INSTALL TREMCO BARRIER SOLUTIONS DRAINSTAR Z-DRAIN (DRAINAGE MAT W/ FILTER
FABRIC) OVER WATERPROOFING MATERIAL. INSTALLATION BY MANUFACTURER
APPROVED INSTALLERS PER MANUFACTURER DETAILS AND REQUIREMENTS.
CRAWL SPACE NOTES
CRAWL SPACE VAPOR BARRIER
12 MIL ANTIMICROBIAL CRAWL SPACE LINER BY TUFF SCRIM . ALL JOINTS TO
BE TAPED AND VAPOR BARRIER SHALL BE INSTALLED PER MANUFACTURERS
REQUIREMENTS. EXTEND UP SIDE WALLS A MIN. OF 12"
WALL &CEILING PENETRATIONS
REFER TO 2015 INTERNATIONAL RESIDENTIAL CODE FOR REQUIREMENTS
FOR ALL PENETRATIONS THRU RATED WALLS, FLOOR/CEILING, AND
CEILING/ROOF.
ROOF ASSEMBLY NOTES
ROOF /ATTIC VENTILATION
BIRD BLOCK VENTS @ALL EAVES AND RIDGE VENTS AT LOCATIONS AS
SHOWN ON ROOF PLAN. SEE ROOF VENT CALCULATIONS ON ROOF PLAN
1/300th ATTIC AREA ROOF VENTILATION W/ 1/2 AT EAVE LINE AND 1/2 AT
RIDGE VENTS. PROVIDE CROSS VENTILATION. 1"MIN. AIR SPACE ABOVE
INSULATION ABOVE PER SECTION 1505.3 MIN. 3 SQ. FT. PROVIDE WIND
BAFFLE W/ 1"AIR SPACE ABOVE ATTIC INSULATION. EXTEND TO A POINT 12"
VERTICALLY ABOVE INSULATION.
TYPICAL ROOF CONSTRUCTION
CONTRACTOR SHALL INSTALL A 30 YEAR ASPHALT COMPOSITION SHINGLES
(CERTAINTEED PRESIDENTIAL SERIES) -COLOR SELECTION BY OWNER;
OVER OWENS CORNING PROARMOR 42-IN X 286-FT 1000-SQ FT SYNTHETIC
ROOF UNDERLAYMENT OVER SHEATHING (AS SCHEDULED BY STRUCTURAL
ENGINEER OVER SCHEDULED FRAMING MEMBERS.
ALL ROOF VALLEYS SHALL HAVE A 36"WIDE CONTINUOUS STRIP OF GRACE
ICE -WATER SHIELD (EQUALLY SPACED AT CENTERLINE OF ROOF VALLEY)
AND DARK BRONZE METAL VALLEY FLASHING
REFER TO ROOF PLAN FOR ALL STRUCTURAL FRAMING SIZES.
REFER TO STRUCTURAL GENERAL NOTES FOR PANEL NAILING
INSTRUCTIONS AND ATTACHMENT INFORMATION ON ALL STRUCTURAL
MEMBERS.
REFER TO ROOF FRAMING PLAN FOR ALL HOLD DOWN TIES OR CLIPS. ROOF
LIVE LOAD PER STRUCTURAL DRAWINGS.
BRACE WALLS PER 2015 INTERNATIONAL RESIDENTIAL CODE
ROOF GUTTER CONSTRUCTION
REFER TO ROOF PLAN FOR NOTES ON ROOF GUTTERS AND DOWNSPOUTS.
CEILINGS AT ATTIC SPACE
1/2" PTD. GWB OVER MEMBRAIN SMART VAPOR RETARDER VAPOR BARRIER
OR BENJAMIN MOORE'S SUPER SPEC LATEX VAPOR BARRIER PRIMER
SEALER 260 OVER SCHEDULED CEILING JOISTS @ 24" O.C. W/ R-49 BATT
INSULATION.
CONC. SLAB /INSULATION
CONCRETE FLOOR SLAB
ALL CONCRETE SLABS SHALL HAVE SMOOTH FINISH AND SHALL BE A MINIMUM
OF 4" THICK OVER UNDERSLAB VAPOR RETARDER (STEGO WRAP 15 MIL.
REINFORCED PLASTIC) OVER 4" FREE DRAINAGE GRAVEL (W/ NO FINES).
SEE STRUCTURAL DRAWINGS FOR REINFORCING AND MIX INFORMATION.
CONCRETE SLABS BELOW HEATED AREAS SHALL HAVE R-10 RIGID INSULATION
(2" THICK) BELOW SLAB. PROVIDE P.T. 2x4 BETWEEN SLAB EDGE AND
FOUNDATION WALL WHERE SLAB IS LESS THAN 2' BELOW FINISH GRADE.
FLOOR, STAIRS. GUARDRAILS
FLOORS /CEILINGS
GLUE 3/4" T&G PLYWOOD SUBFLOOR (SCREWS @ 6" O.C. @EDGES -10" O.C. AT
INTERMEDIATE FRAMING MEMBERS) OVER SCHEDULED FLOOR JOISTS ORTRUSS -
GLUE TO EACH JOIST. FLOOR LOAD : 10 PSF DEAD LOAD 40 PSF LIVE LOAD. INSTALL
1/2" PTD. G.W.B. CEILING AT UNDERSIDE OF JOISTS. INSTALL R-30 BATT INSULATION
BELOW PLYWOOD SUBFLOOR OVER UNHEATED AREAS.
SEE BUILDING SECTION FOR AREAS OF PARALLEL CHORD WOOD TRUSSES.
SEE OCCUPANCY SEPARATION NOTES FOR GARAGE CEILING GYPSUM WALLBOARD
REQUIREMENTS.
STAIR /STEPS CONSTRUCTION
1) MAXIMUM RISE SHALL BE 7-3/4": MINIMUM RUN SHALL BE 11": HEADROOM MINIMUM
SHALL BE 6'-8":WIDTH SHALL BE 36"MINIMUM. REFER TO FLOOR PLANS FOR
SCHEDULED STAIR WIDTH, RISER DIMENSIONS, AND TREAD DIMENSIONS.
2.) HANDRAILS TO HAVE ENDS RETURNED TO WALL OR NEWEL POST AND PLACED
MINIMUM 34", MAXIMUM 38" ABOVE TREAD NOSING.
3.) THE HAND GRIP PORTION OF HANDRAILS SHALL BE NOT LESS THAN 1-1/2" NOR
MORE THAN 2" IN CROSS -SECTIONAL DIMENSION OR THE SHAPE SHALL PROVIDE AN
EQUIVALENT GRIPPING SURFACE. THE HANDRAIL GRIP PORTION OF HANDRAILS
SHALL HAVE A SMOOTH SURFACE WITH NO SHARP CORNERS. HANDRAILS
PROJECTING FROM A WALL SHALL HAVE A SPACE OF NET LESS THAN 1-1/2"
BETWEEN THE WALL AND HANDRAIL.
4) WHEN DECKS, LANDING OR PORCHES ARE MORE THAN 30" ABOVE GRADE,
PROVIDE GUARDRAILS NOT LESS THAN 36"HIGH WITH INTERMEDIATE MEMBERS
SPACED SUCH THAT A SPHERE 4" IN DIAMETER CANNOT PASS THROUGH. (DECKS
ACCESSIBLE ONLY TO INDIVIDUAL UNITS OR AREAS WITHIN INDIVIDUAL UNITS MAY
USE 36"HIGH GUARDRAILS).
ALL STAIRS SHALL HAVE SOLID RISERS (EXTERIOR STAIR TREADS AND RISERS SHALL
BE TREX TYPE SYNTHETIC SURFACES).
GUARDRAILS ARE TO BE DESIGNED TO RESIST A 200 LB. CONCENTRATED LOAD ON
THE TOP RAIL AND 50 PSF ON ALL GUARDRAIL INFILL COMPONENTS.
PATIO CONSTRUCTION
1) ALL PATIOS SHALL BE CONSTRUCTED WITH THE FOLLOWING MATERIALS:
PATIO SURFACE: 4" CONCRETE SLAB ON COMPACTED GRAVEUFILL WITH
EXPOSED AGGREGATE FINISH. SEE FLOOR PLAN FOR CONTROL JOINT
LOCATION.
2) PATIOS SHALL BE CONSTRUCTED AS SHOWN ON LOWER LEVEL FLOOR PLAN
DRAWINGS.
PORCH &DECK CONSTRUCTION
PORCH AND RAISED DECKS
LEVEL 1 COVERED DINING DECK SHALL BE SYNTHETIC WATERPROOF DECK
COATING (SELECTION &COLOR BY OWNER) OVER PRESSURE TREATED
PYLYWOOD OVER PRESSURE TREATED FRAMING WOOD FRAMING. (SEE
STRUCTURAL DRAWINGS FOR DECK FRAMING AND DECK SUPPORT POST
INFORMATION)
ENTRY PORCH, REAR PORCH @LEVEL 1, AND STEPS TO DECKS SHALL BE
SYNTHETIC DECKING MATERIAL (SELECTION BY OWNER) OVER PRESSURE
TREATED WOOD FRAMING. SEE STRUCTURAL DRAWINGS FOR FRAMING
INFORMATION.
LEVEL 1 COVERED DINING DECK SHALL HAVE ATOP -MOUNTED GUARDRAIL
SYSTEM (36"HIGH ABOVE WALKING SURFACE) AND VERTICAL BALUSTERS
SHALL BE PLACED SO THAT A 4" DIAMETER SPHERE WILL NOT PASS
BETWEEN BALUSTERS OR STRINGERS. SEE ELEVATION DRAWINGS AND
DECK DETAILS FOR ADDITIONAL INFORMATION.
BASEMENT PORCH: SEE STRUCTURAL DRAWINGS FOR SLAB THICKNESS &
REINFORCING.
BASEMENT PORCH SHALL BE 4"THICK CONCRETE SLAB.
ALL CONRETE PORCHES, STEPS, WALKWAYS, AND PAVERS SHALL BE
INSTALLED ON GRAVEL BASE OVER COMPACTED SOIL PER STRUCTURAL
ENGINEERING STANDARDS.
FIREBLOCKING
FIREBLOCK CONSTRUCTION
1. INSTALL FIREBLOCKING MADE OF MATERIALS AS ALLOWED BY THE 2015
EDITION OF THE 2015 INTERNATIONAL RESIDENTIAL CODE.
2. PROVIDE FIREBLOCKS AROUND VENTS AND PIPES AND AT VERTICAL
OPENINGS WHERE EXHAUST FAN DUCTS ARE ROUTED TO ROOFTOP
EXHAUST VENTS. PROVIDE STRAPPING AS REQUIRED BY CODE.
3. PROVIDE AND INSTALL FIREBLOCKS AT ALL LOCATIONS IDENTIFIED IN
2012
EDITION OF THE INTERNATIONAL RESIDENTIAL CODE AND AS FOLLOWS:
A) IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS AT THE
CEILING
AND FLOOR LEVELS AT AT 10 FOOT INTERVALS BOTH VERTICAL AND
HORIZONTAL.
B) AT ALL INTERCONNECTIONS BETWEEN CONCEALED VERTICAL AND
HORIZONTAL SPACES SUCH AS OCCUR AT SOFFITS, DROP CEILINGS, AND
COVE CEILINGS.
C) IN CONCEALED SPACES BETWEEN STAIR STRINGERS AT THE TOP AND
BOTTOM OF THE RUN AND BETWEEN STUDS ALONG AND IN LINE WITH THE
RUN OF STAIRS IF THE WALLS UNDER THE STAIRS ARE UNFINISHED.
D) IN OPENINGS AROUND VENTS, PIPES, DUCTS, CHIMNEYS, FIREPLACES
AND
SIMILAR OPENINGS THAT AFFFORD A PASSAGE FOR FIRE AT CEILING AND
FLOOR LEVELS, WITH NONCOMBUSTIBLE MATERIALS.
E) AT OPENINGS BETWEEN ATTIC SPACES AND CHIMNEY CHASES FOR
FACTORY BUILT CHIMNEYS.
ROOF CONSTRUCTION
SEE CONSTRUCTION
ASSEMBLY NOTES BELOW
FOR INFORMATION
Upper Tom Plate
18.58
HEADERS @EXT. DOORS &WINDOWS
ALL HEADERS @EXTERIOR WALLS
SHALL BE INSULATED PER CODE
STANDARDS (TYPICAL)
00
�vel 2
10.49
M
Level 1 Tom P
Levell �
0.00
T_O.F.W. N
-1.18
CONTRACTOR NOTE
TOP & BOTTOM OF FOOTING ELEVATIONS
ARE APPROXIMATE ONLY. ACTUAL
_ ELEVATIONS WILL DEPEND UPON FINISH
GRADE &DEPTH OF BEARING SOIL -
(TYPICAL @ALL FOOTINGS)
FOOTING DRAINS IN FILTER FABRIC SOCK
AND GRAVEL FILL -FILTER FABRIC @TOP
& SIDE OF GRAVEL FILL. CONNECT TO
DRAINAGE SYSTEM PER CIVIL DRAWINGS
-9.27
HEATING /PLUMBING NOTES
SEE ELECTRICAL PLAN, VENTILATION NOTES, &AIR QUALITY NOTES ON
SHEET A-2.3 FOR ADDITIONAL HVAC INFORMATION AND REQUIREMENTS
GAS FIRED FURNACE HEATING SYSTEM
HEAT WILL BE SUPPLIED BY A GAS FIRED FURNACE W/ FRESH AIR INTAKE
AND INTEGRATED WHOLE HOUSE EXHAUST FAN (W/TIMER).
GENERAL CONTRACTOR AND HEATING SUBCONTRACTOR SHALL
COORDINATE ALL DUCT LAYOUT LOCATIONS AND ROUTING OF DUCTS PRIOR
TO FRAMING PROCESS. ALL DUCTWORK IN UNHEATED SPACE SHALL BE
INSULATED DUCT WITH A MIN. RATING OF R-8.
WATER HEATER
A GAS WATER HEATER SHALL BE INSTALLED IN MECHANICAL ROOM. REFER
TO FURNACE &WATER HEATER NOTES FOR INFORMATION
PLUMBING NOISE CONTROL &INSULATION
NOISE CONTROL
ALL PLUMBING SUPPLY AND DRAIN LINES SHALL BE WRAPPED WITH FOAM
PIPE INSULATION. HOT WATER LINES SHALL REWRAPPED W/ R-5 INSULATION
INTERIOR PLUMBING WALLS SHALL BE INSULATED WITH SOUND BATT
INSULATION.
PLUMBING LINES
PEX SUPPLY (WATER HOT AND COLD), ABS FOR VENT, AND CAST IRON FOR
WASTE THAT RUNS THROUGH LIVING SPACE. ABS WASTE IN BASEMENT
SLAB OR CRAWLSPACE.
DRYER VENTING
DRYER VENTING - W.S.E.C. SEC. M1502.4.5 STATES, "WHERE THE EXHAUST DUCT
IS CONCEALED WITHIN THE BUILDING CONSTRUCTION, THE EQUIVALENT
LENGTH OF THE EXHAUST DUCT SHALL BE INDENTIFIED ON A PERMANENT
LABEL OR TAG. THE LABEL OR TAG SHALL BE LOCATED WITHIN 6 FT. OF THE
EXHAUST DUCT CONNECTION".
INSTALL DOWN VENT METAL DRYER BOX BEHIND DRYER AND EXTEND METAL
DUCT TO SIDEWALL OF HOUSE.. SEE UPPER FLOOR PLAN FOR NOTES.
SPRINKLER SYSTEM
THIS RESIDENCE NOT REQUIRED TO BE SPRINKLERED.
INSULATION R-VALUES
PER WASHINGTON STATE ENERGY CODE ,THE INSULATION VALUES ARE R-21 FOR
WALLS, R-38 FOR FLOORS OVER UNHEATED SPACE, AND R-49 IN ATTIC SPACE.
INSULATION CERTIFICATE
BUILDER SHALL COMPLETE AND POST AN "INSULATION CERTIFICATE FOR
RESIDENTIAL CONSTRUCTION" WITHIN 3' OF THE ELECTRICAL PANEL PRIOR TO FINAL
INSPECTION.
ROOF ASSEMBLY PER NOTES
@ BOTTOM OF THIS SHEET
2 x BIRD BLOCK VENTS BETWEEN TRUSSES
METAL DRIP EDGE
TO EXTEND DOWN
INTO GUTTER
�, � GUTTER GUARD. SEE
ROOF PLAN SHEET
SMOOTH PLYWOOD FOR TYPE
PANELS AT AREA
OF EXPOSED PER ROOF LAN PTD. ALUM GUTTER
EAVES (TYP) PRIMED &PTD. 514 x 8
CEDAR FASCIA BOARD
SEE ROOF PLAN FOR ROOF OVERHANG
DIMENSIONS
�� Roof Eave Detail
PREPRIMING AND PAINTING OF
EXTERIOR WOOD SURFACES
ANY NATURAL WOOD SIDING OR WOOD
TRIM �a EXTERIOR SHALL BE PRE -
PRIMED (BY PAINTER OR SUPPLIER) AT
ALL SIDES (BEFORE INSTALLATION) AND
SHALL BE PAINTED W/ EXTERIOR PAINT
AS SELECTED BY OWNER.
ALL EXTERIOR WOOD TRIM SHALL HAVE
SMOOTH SURFACE
GARAGE REQUIREMENTS
OCCUPANCY SEPARATION
OCCUPANCY SEPARATION BETWEEN GARAGE AND LIVING SPACE
5/8" TYPE X G.W.B. (TYP)
CEILINGS:1 LAYER ON ALL TRUSSES AND TJI's (1 LAYER ON STICK FRAMING @
16" O.C. OR LESS)
WALLS: 1 LAYER ON COMMON WALLS TO ROOF SHEATHING / 1 LAYER ON
WALLS TO SUPPORT PROTECTED CEILINGS
POSTS AND BEAMS: 1 LAYER
DOOR TO LIVING AREA: INSTALL 1-3/8" SOLID CORE WOOD DOOR WITH SELF
CLOSER AND WEATHERSTRIP
GARAGE INSULATION
AT WALLS BETWEEN GARAGE AND HEATED SPACE, INSTALL 2x 6 STUD WALLS
(@ 16" O.C.) W/ R-21 BATT INSULATION. AT CEILINGS BETWEEN GARAGE AND
HEATED AREAS ABOVE, INSTALL R-38 BATT INSULATION BETWEEN SCHEDULED
JOISTS, INSTALL R-10 RIGID INSULATION BELOW SLAB AT HEATED AREAS.
DUCTS IN GARAGE
DUCTS IN THE GARAGE AND DUCTS PENETRATING THE WALLS OR CEILINGS
SEPARATING THE DWELLING FROM THE GARAGE SHALL BE CONSTRUCTED OF
A MINIMUM N0.26 GAGE SHEET STEEL OR OTHER APPROVED MATERIAL AND
SHALL HAVE NO OPENINGS INTO THE GARAGE.
DUCTS IN GARAGE
DUCTS IN THE GARAGE AND DUCTS PENETRATING THE WALLS OR CEILINGS
SEPARATING THE DWELLING FROM THE GARAGE SHALL BE CONSTRUCTED
OF A MINIMUM N0.26 GAGE SHEET STEEL OR OTHER APPROVED MATERIAL
AND SHALL HAVE NO OPENINGS INTO THE GARAGE.
ADDITIONAL INSULATION
REQUIREMENTS
IN ADDITION TO INSULATION REQUIREMENTS NOTED ELSEWHERE IN
THIS SET OF DRAWINGS, THE FOLLOWING REQUIREMENTS FROM THE
2015 W.S.E.C. SHALL BE FOLLOWED:
1) INSULATED HEADERS (ALL VOIDS FILLED TO MIN. R-10.
2) NO WALL STACKS IN EXTERIOR WALL CAVITIES
3) DUCTS IN FLOOR/CEILING ASSEMBLIES SHALL NOT DISPLACE R-30
INSULATION
4) RETURN AIR MUST BE DUCTED (NON -DUCTED JOIST BAYS NOT
ALLOWED).
5) PER SELECTED ENERGY CREDIT OPTION, WINDOWS SHALL HAVE A U
VALUE OF 0.28, R-38 INSULATION III®I� ��UD AREAS D AREAS,
R-10 RIGID INSULATION BELOW SL /fFf
6) ALL PLUMBING WALLS SHAVE HA�F�Sglf1�LATION AND ALL
PLUMBING LINES SHALL BE WRAPPED of EgMo p IIPE INSULATION
DEVELOPMENT SERVICES
DEPARTMENT
Carl J. Colson -Architect
PLLC
23623 20th Ave. W
Bothell, WA 98021
425-806-3703
wwwCarlColsonArchitect.com
Commercial &Residential
Architecture
Evans Residence
Project Address
20018 83rd Ave. W.,
Edmonds, WA 98026
New SFR at 20018 83rd Ave. W (Lot 1 of
PLN20180037)
City of Edmonds Permit #: BLD2020-0250
Project Client
Marne &Simon Evans
20020 83rd Ave. W.
Edmonds, WA 98026
Sheet Title
North Building
Section
7543 REGISTERE
ARCHITECT
G,�'"� '
CARL J. COLSON
S ATE OF WASHINGTO
ISSUED FOR PERMIT 1-21-2020
Document Set Type:
Revision Schedule
Rev.
# Date Description
1 6-15-2020 IAdd Window/ Permit Revisions
DRAWING USE NOTIFICATION
This set of drawings is being issued as a Progress or Permit Set of Drawings
and is subject to change and adding of additional information and
drawings as required by review of the Building Department in the
jurisdiction where this project is located.
DO NOT USE THIS DRAWING FOR CONSTRUCTION UNLESS THIS
DRAWING HAS A BUILDING DEPARTMENT "APPROVED" STAMP
APPLIED BY THE BUILDING DEPARTMENT UPON COMPLETION OF
THE PERMIT REVIEW PROCESS.
Do not use this drawing for Bidding or Estimating Purposes unless
authorized by Client. During Construction Phase, the Clients General
Contractor (Builder) or Developer shall be responsible for ensuring that all
Construction Personnel of the General Contractor and all Subcontractors
are supplied with all A�provecl and most current documents.
ARCHITECTURAL COPYRIGHT
This sheet of drawings may not be reproduced in any form without prior
approval of Carl J. Colson -Architect PLLC.
These document, the ideas, and designs incorporated herein as an
instrument of service shall remain the ro ert of Carl .Colson -Architect
p p y 1
PLLC and are solely for the use on this project only. These files, drawings,
ideas, or designs may not be tramsmitted electronically without express
permission of Architect. They are not be used by the client or any other
party or entity on other projects, in whole or part, or as an extension to this
project except by agreement in writing with appropriate financial
compensation to Carl J. Colson -Architect PLLC.
Copyright Carl J. Colson -PLLC, 2019. All rights reserved.
Project Number
Sheet Issue Date �
04/22/13 �
Drawn By
Author North Building Section
Scale
As indicated Sheet PlotDat�i/14/2020 7:44:50 PM
www.CarlColsonArchitect.com
00
M
o�
N
Upper Top Plate —
18.58
OPENING @END WALL
OPENING SHALL BE TRIMMED wl TRIM
TO MATCH WINDOW EXTERIOR TRIM.
HEAD HEIGHT OF OPENING TO
MATCH HEAD HEIGHT OF WINDOWS
@ THIS FLOOR LEVEL
Level2 —
10.49
Level 1 Top Plate
PORCH ROOF/CEILING FRAMING:
SEE STRUCTURAL DRAWINGS FOR
ALL FRAMING INFORMATION
CEILING BOX BEAM WRAPPED WI PRIMED
AND PAINTED 1 x CEDAR WOOD TRIM). SEE
STRUCT. DRAWINGS FOR BEAM SIZES
SEE SHEET A-3.1 FOR PORCH
COLUMNS DETAIL
36"HIGH RAILING @THIS PORCH. SEE
DETAIL ON SHEET A-4.4
WRAPPED BEAM SUPPORT DETAIL. -
SEEDETAIL ON SHEET A-4.4
Level 1
0.00
T_O. F_W .
-1.18
PRIMED AND PAINTED TONGUE AND -
GROOVEDBOARDS CEILING AT ENTRY
AND KITCHEN PORCH.. SEE
STRUCTURAL DRAWINGS FOR PORCH
ROOF/CEILING FRAMING INFORMATION
4" CONC. PATIO SLAB OVER COMPACTED
GRAVEL FILL. HOLD SLAB DOWN 1-112"
BELOW FLOOR LEVEL. SLOPE SLAB TO
DRAIN AWAY FROM HOUSE.
DASHED LINES INDICATE LOCATION OF
PORCH COLUMN FOOTINGS. SEE
STRUCTURAL DRAWINGS
Basement
-9.27
CONSTRUCTION ASSEMBLY NOTES
WALL ASSEMBLY NOTES
SEE NOTES ABOUT MOLD, PRESSURE TREATED WOOD AND FASTENERS ON SHEET A-1.2
FIRE RATED ASSEMBLIES
REFER TO SHEET 2-1 AND NOTES BELOW FOR FIRE/OCCUPANCY SEPARATION
REQUIREMENTS BETWEEN GARAGE AND LIVING SPACE
TYPICAL EXTERIOR WALL CONSTRUCTION
HARDIE-PLANK LAP SIDING (SMOOTH FINISH AND MATCHING CAULK) W/ 6" EXPOSURE
OVER BENJAMIN OBDYKE HYDROGAP DRAINABLE HOUSEWRAP OVER 1/2" EXT. PLYWOOD
(OR 7/16" O.S.B.). SHEATHING OVER 2x6 STUDS @ 16" O.C. W/ R-21 BATT INSULATION AND
1/2" PTD. GWB OVER MEMBRAIN SMART VAPOR RETARDER VAPOR BARRIER (OR
BENJAMIN MOORE'S SUPER SPEC LATEX VAPOR BARRIER PRIMER SEALER 260). SEE
ELEVATION DRAWINGS FOR SPECIFIED SIDING MATERIALS.
ANY NATURAL WOOD SIDING OR WOOD TRIM @EXTERIOR SHALL BE PRE -PRIMED AT ALL
SIDES (BEFORE INSTALLATION) AND PAINTED W/ EXTERIOR PAINT.
SEE ELEVATION DRAWINGS FOR SPECIFIED SIDING MATERIALS.
STONE VENEER EXTERIOR WALL CONSTRUCTION
SYNTHETIC STONE VENEER (SELECTION BY OWNER) OVER CEMENT BACKERBOARD OVER
WATERPROOF MEMBRANE OVER PRESSURE TREATED PLYWOOD SHEATHING OVER 2x6
STUD WALL. TOP OF STONE VENEER SHALL HAVE PRIMED AND PAINTED CEDAR COPING
OR COPING BY STONE MANUFACTURER (OWNER SELECTION) w/METAL FLASHING @TOP
EDGE.
TYPICAL INTERIOR WALL CONSTRUCTION
1/2" PAINTED GYPSUM WALLBOARD (GWB) AT EACH SIDE OFWALL W/ 2x4 STUDS @ 16"
O.C. USE 1/2" WATER RESISTANT GYP. BD. @ALL KITCHEN, BATHROOM, AND LAUNDRY
ROOM LOCATIONS. USE WONDERBOARD (CEMENT BACKERBOARD) BACKING BEHIND
ALL TUBS, SHOWERS, AND TILE LOCATIONS
GARAGE WALL CONSTRUCTION
(SEE OCCUPANCY SEPARATION NOTES FOR WALL AND CEILING CONSTRUCTION
BETWEEN GARAGE AND LIVING AREAS)
5/8" PTD. TYPE X GYPSUM WALLBOARD (FIRETAPED) AT INTERIOR FACE OF WALL
WITH 2x4 OR 2x6 STUDS @ 16" O.C.. EXTERIOR FACE OF WALL SHALL BE PRE-
PRIMEDAND PAINTER CEDAR OR HARDIE-PLANK HORIZONTAL LAP SIDING OVER
FORTIFIBER WEATHERSMART DRAINABLE OR BENJAMIN OBDYKE HYDROGAP DRAINABLE
HOUSEWRAP OVER 1/2" EXT. PLYWOOD SHEATHING. REFER TO BUILDING ELEVATIONS
FOR LOCATION OF CULTURED STONE VENEER TO BE APPLIED IN LIEU OF WOOD SIDING.
WALL ANCHORING
UNLESS SHOWN OTHERWISE ON STRUCURAL OR FRAMING DRAWINGS, BOLT APPROVED
MUD SILL (PER SEC 2317.4 TO TOP OF CONC. WALL W/ 5/8" x 10"ANCHOR BOLTS @ 4'-0" O.C.
& 1'-0" O.C. FROM EACH SPLICE PER SEC 1806.5. PROVIDE TERMITE SHIELD AT MUDSILL
BASEMENT WALL WATERPROOFING (IF USED ON PROJECT
TUFF-N-DRI H8 WATERPROOFING MEMBRANE AT ALL BELOW GRADE BASEMENT WALLS
INSTALL TREMCO BARRIER SOLUTIONS DRAINSTAR Z-DRAIN (DRAINAGE MAT W/ FILTER
FABRIC) OVER WATERPROOFING MATERIAL. INSTALLATION BY MANUFACTURER
APPROVED INSTALLERS PER MANUFACTURER DETAILS AND REQUIREMENTS.
HEADERS @EXT. DOORS &WINDOWS
ALL HEADERS @EXTERIOR WALLS
SHALL BE INSULATED PER CODE
STANDARDS (TYPICAL)
OPEN TO BEYOND
Dinin P� orch
OPEN TO BEYOND
Rec Room Porch
.° tl 1 - - a
D
CRAWL SPACE NOTES
CRAWL SPACE VAPOR BARRIER
12 MIL ANTIMICROBIAL CRAWL SPACE LINER BY TUFF SCRIM . ALL JOINTS TO
BE TAPED AND VAPOR BARRIER SHALL BE INSTALLED PER MANUFACTURERS
REQUIREMENTS. EXTEND UPSIDE WALLS A MIN. OF 12"
WALL &CEILING PENETRATIONS
REFER TO 2015 INTERNATIONAL RESIDENTIAL CODE FOR REQUIREMENTS
FOR ALL PENETRATIONS THRU RATED WALLS, FLOOR/CEILING, AND
CEILING/ROOF.
ROOF ASSEMBLY NOTES
ROOF /ATTIC VENTILATION
BIRD BLOCK VENTS @ALL EAVES AND RIDGE VENTS AT LOCATIONS AS
SHOWN ON ROOF PLAN. SEE ROOF VENT CALCULATIONS ON ROOF PLAN
1/300th ATTIC AREA ROOF VENTILATION W/ 1/2 AT EAVE LINE AND 1/2 AT
RIDGE VENTS. PROVIDE CROSS VENTILATION. 1"MIN. AIR SPACE ABOVE
INSULATION ABOVE PER SECTION 1505.3 MIN. 3 SQ. FT. PROVIDE WIND
BAFFLE W/ 1"AIR SPACE ABOVE ATTIC INSULATION. EXTEND TO A POINT 12"
VERTICALLY ABOVE INSULATION.
TYPICAL ROOF CONSTRUCTION
CONTRACTOR SHALL INSTALL A 30 YEAR ASPHALT COMPOSITION SHINGLES
(CERTAINTEED PRESIDENTIAL SERIES) -COLOR SELECTION BY OWNER;
OVER OWENS CORNING PROARMOR 42-IN X 286-FT 1000-SQ FT SYNTHETIC
ROOF UNDERLAYMENT OVER SHEATHING (AS SCHEDULED BY STRUCTURAL
ENGINEER OVER SCHEDULED FRAMING MEMBERS.
ALL ROOF VALLEYS SHALL HAVE A 36"WIDE CONTINUOUS STRIP OF GRACE
ICE -WATER SHIELD (EQUALLY SPACED AT CENTERLINE OF ROOF VALLEY)
AND DARK BRONZE METAL VALLEY FLASHING
REFER TO ROOF PLAN FOR ALL STRUCTURAL FRAMING SIZES.
REFER TO STRUCTURAL GENERAL NOTES FOR PANEL NAILING
INSTRUCTIONS AND ATTACHMENT INFORMATION ON ALL STRUCTURAL
MEMBERS.
REFER TO ROOF FRAMING PLAN FOR ALL HOLD DOWN TIES OR CLIPS. ROOF
LIVE LOAD PER STRUCTURAL DRAWINGS.
BRACE WALLS PER 2015 INTERNATIONAL RESIDENTIAL CODE
ROOF GUTTER CONSTRUCTION
REFER TO ROOF PLAN FOR NOTES ON ROOF GUTTERS AND DOWNSPOUTS.
CEILINGS AT ATTIC SPACE
1/2" PTD. GWB OVER MEMBRAIN SMART VAPOR RETARDER VAPOR BARRIER
OR BENJAMIN MOORE'S SUPER SPEC LATEX VAPOR BARRIER PRIMER
SEALER 260 OVER SCHEDULED CEILING JOISTS @ 24" O.C. W/ R-49 BATT
INSULATION.
ROOF RIDGE VENTS
SEE ROOF PLAN FOR ALL RIDGE VENT
LOCATIONS &ROOF VENT CALCULATIONS
TRIM INTERIOR FAC OPENING TO
MATCH EXTERIOR T I
STONE CAP PANELS R 2" POURED C.
PANEL) OVER CEME BOARD OVER
MEMBRANE OVER P. PLYWOOD'
SHEATHING @TOP FIREPLACE
ENCLOSURE. SEE F F�PLAN
STONE VENEER (OVER CEMENT BOARD OVER
�, W. P. MEMBRANE OVER W.R.B.M OVER P.T.
PLYWOOD SHEATHING) @FIREPLACE
ENCLOSURE. SEE FLOOR PLAN
�� REAR VENTED GAS FIREPLACE. SELECTION
BY OWNER
�� KITCHEN CABINETS NOT SHOWN FOR —
CLARITY OF DRAWING
VENTILATED WOOD FRAMED DECK (Wi
WATERPROOF COATING OVER VAPOR BARRIER
OVER P.T. PLYWOOD SHEATHING OVER
PRESSURE TREATED WOOD FRAMING). SLOPE
DECK TO DRAIN 114" PER FT.
TRIM INTERIOR FACE OF OPENING
TO MATCH EXTERIOR TRIM
BASEMENT SLAB
4" REINFORCED CONC. SLAB (w/
THICKENED EDGES) OVER VAPOR
BARRIER OVER 2" R-10 RIGID
INSULATION OVER 4" COMPACTED
GRAVEL FILL. INSTALL CRACK CONTROL
JOINTS
T�
i��/ �
�--� ���
SEE WINDOW SCHEDULE SHEET
FOR ALL INTERIOR DOOR &
WINDOW TRIM INFORMATION
Master Bathroom
/INTERIOR
NDOWTRIMNOT
SHOWN 0
INDOWS @THIS
SECTION
AWING. REFER TO
WINDOW
EDULE SHEET
FO�TRIM
TAILS (TYP)
Kitchen
FLOOR FRAMING
FRAMING IS SCHEMATIC ONLY.
SEE STRUCTURAL DRAWINGS
FOR ALL FLOOR JOIST SIZES,
SPACING, SUPPORT POSTS, AND
POST FOOTINGS
Guest Bedroom
SKYLIGHT. SEE ROOF ROOF TRUSS
PLAN FOR LOCATION PRE-ENGINEERED ROOF TRUSSES @ 24" O.C. -
SEE STRUCTURAL DRAWINGS.
�' TRUSS LAYOUT SHOWN IS SCHEMATIC ONLY.
REFER TO ROOF PLAN &EXTERIOR ELEVATIONS
FOR ROOF DESIGN THAT INCLUDES GABLES,
HIPS, OR OVERFRAMED AREAS.
CEILING AT ATTIC
SEE ASSEMBLY NOTES
BELOW FOR CEILING
CONSTRUCTION
EXTERIOR WALL
SEE WALL
CONSTRUCTION i
ASSEMBLY NOTES
BELOW FOR
EXTERIOR WALL
CONSTRUCTION
DOOR TO TOILET
COMPARTMENT i
��
Powder
Room
INTERIOR WALL
SEE WALL CONSTRUCTION
ASSEMBLY NOTES BELOW
FOR INTERIOR WALL
CONSTRUCTION
PRIMED AND PAINTED SMOOTH
PLYWOOD SHEATHING AT AREA OF
EXPOSED EAVES (TYP)
SHOWER @THIS AREA NOT SHOWN
FOR CLARITY OF DRAWING
PARALLEL CHORD WOOD FLOOR TRUSSES
@ UPPER LEVEL ONLY. (FRAMING SHOWN
IS SCHEMATIC ONLY -SEE STRUCTURAL
DRAWINGS FOR SIZE, FRAMING LAYOUT,
AND SUPPORTING BEAMS AT THIS AREA)
R-49 INSULATION @ATTIC
Laundry Room
(CABINETS NOT SHOWN
FOR CLARITY OF DRAWING
FLOOR INSULATION
R-381NSULATION @FLOORS
OVER UNHEATED SPACES
FLOOR CONSTRUCTION
SEE ASSEMBLY NOTES BELOW FOR
FLOOR CONSTRUCTION OVER
11NHFATF� ARFA
SEE CONSTRUCTION
ASSEMBLY NOTES BELOW
FOR INFORMATION
ROOF SLOPE &OVERHANG
SEE ROOF PLAN FOR ALL
ROOF SLOPE AND
OVERHANG INFORMATION
BIRDBLOCK VENTS @ALL
EAVES (TYP)
PAINTED 2 x 8 CEDAR
FASCIA BOARD. PRE -
PRIMED @ALL SIDES (TYP)
STRUCTURAL FRAMING
SEE STRUCTURAL DRAWINGS
FOR ALL FLOOR FRAMING AND
SUPPORT POSTS, FOUNDATION
WALLS & FOOTINGS IN CRAWL
SPACE (TYPICAL)
CRAWL SPACE ACCESS ' -� STEPPED FOUNDATION ' � � I ��
SEE FLOOR PLANS FOR WALL BEYOND PER I ' a ° -
CRAWLSPACE ACCESS HATCH � , � � �� STRUCT. DRAWINGS & �_ � ,
SITE CONDITIONS ; � I CONTRACTOR NOTE
- � '� p � TOP &BOTTOM OF FOOTING ELEVATIONS
VENTILATED CRAWL SPACE � � °. � ARE APPROXIMATE ONLY. ACTUAL
�- �" � �� � _ ° _ �_ —_ ELEVATIONS WILL DEPEND UPON FINISH
�' � GRADE & DEPTH OF BEARING SOIL
. � —
' �—�l�f
�, (TYPICAL @ALL FOOTINGS)
a I� � � � � � — FOOTING DRAINS IN FILTER FABRIC SOCK
a � — AND GRAVEL FILL -FILTER FABRIC @TOP
° , i � & SIDE OF GRAVEL FILL. CONNECT TO
- -T III I — DRAINAGE SYSTEM PER CIVIL DRAWINGS
BASEMENT WALL WATERPROOFING ° i - CRAWL SPACE BARRIER
SEE CONSTRUCTION ASSEMBLY � _ � � _ � _ � VAPOR BARRIER.AS SPECIFIED IN
NOTES BELOW FOR BASEMENT a i j� NOTES ON THIS PAGE. EXTEND UP SIDE
WALL WATERPROOFING SYSTEMS Q �� � _ � _ � �� WALLS A MIN. OF 12"=III III —
i CRAWL SPACE CLEARANCE
a ° a a a_° � MAINTAIN 27"CLEARANCE BETWEEN ;
a
d a ° ° ° n
� BOTTOM OF SUPPORT BEAMS AND CONC. -
i � � � � �c ��c ��o� � � � � � � � � � �c �c �c � � ° � � SLAB �N CRAWL SPACE � � � � � � —
- � FOUNDATION VENTS &WELLS I I I
Q SEE EXTERIOR ELEVATION DRAWINGS &
FOUNDATION PLAN FOR LOCATIONS &VENT
CALCULATIONS ON FOUNDATION PLAN SHEET
,��� South Building Section
CONC. SLAB /INSULATION
CONCRETE FLOOR SLAB
ALL CONCRETE SLABS SHALL HAVE SMOOTH FINISH AND SHALL BE A MINIMUM
OF 4"THICK OVER UNDERSLAB VAPOR RETARDER (STEGO WRAP 15 MIL.
REINFORCED PLASTIC) OVER 4" FREE DRAINAGE GRAVEL (W/ NO FINES).
SEE STRUCTURAL DRAWINGS FOR REINFORCING AND MIX INFORMATION.
CONCRETE SLABS BELOW HEATED AREAS SHALL HAVE R-10 RIGID INSULATION
(2"THICK) BELOW SLAB. PROVIDE P.T. 2x4 BETWEEN SLAB EDGE AND
FOUNDATION WALL WHERE SLAB IS LESS THAN 2' BELOW FINISH GRADE.
FLOOR, STAIRS, GUARDRAILS
FLOORS /CEILINGS
GLUE 3/4" T&G PLYWOOD SUBFLOOR (SCREWS @ 6" O.C. @EDGES -10" O.C. AT
INTERMEDIATE FRAMING MEMBERS) OVER SCHEDULED FLOOR JOISTS ORTRUSS -
GLUE TO EACH JOIST. FLOOR LOAD : 10 PSF DEAD LOAD 40 PSF LIVE LOAD. INSTALL
1/2" PTD. G.W.B. CEILING AT UNDERSIDE OF JOISTS. INSTALL R-30 BATT INSULATION
BELOW PLYWOOD SUBFLOOR OVER UNHEATED AREAS.
SEE BUILDING SECTION FOR AREAS OF PARALLEL CHORD WOOD TRUSSES.
SEE OCCUPANCY SEPARATION NOTES FOR GARAGE CEILING GYPSUM WALLBOARD
REQUIREMENTS.
STAIR /STEPS CONSTRUCTION
1) MAXIMUM RISE SHALL BE 7-3/4": MINIMUM RUN SHALL BE 11": HEADROOM MINIMUM
SHALL BE 6'-8":WIDTH SHALL BE 36"MINIMUM. REFER TO FLOOR PLANS FOR
SCHEDULED STAIR WIDTH, RISER DIMENSIONS, AND TREAD DIMENSIONS.
2.) HANDRAILS TO HAVE ENDS RETURNED TO WALL OR NEWEL POST AND PLACED
MINIMUM 34", MAXIMUM 38" ABOVE TREAD NOSING.
3.) THE HAND GRIP PORTION OF HANDRAILS SHALL BE NOT LESS THAN 1-1/2" NOR
MORE THAN 2" IN CROSS -SECTIONAL DIMENSION OR THE SHAPE SHALL PROVIDE AN
EQUIVALENT GRIPPING SURFACE. THE HANDRAIL GRIP PORTION OF HANDRAILS
SHALL HAVE A SMOOTH SURFACE WITH NO SHARP CORNERS. HANDRAILS
PROJECTING FROM A WALL SHALL HAVE A SPACE OF NET LESS THAN 1-1/2"
BETWEEN THE WALL AND HANDRAIL.
4) WHEN DECKS, LANDING OR PORCHES ARE MORE THAN 30" ABOVE GRADE,
PROVIDE GUARDRAILS NOT LESS THAN 36"HIGH WITH INTERMEDIATE MEMBERS
SPACED SUCH THAT A SPHERE 4" IN DIAMETER CANNOT PASS THROUGH. (DECKS
ACCESSIBLE ONLY TO INDIVIDUAL UNITS OR AREAS WITHIN INDIVIDUAL UNITS MAY
USE 36"HIGH GUARDRAILS).
ALL STAIRS SHALL HAVE SOLID RISERS (EXTERIOR STAIR TREADS AND RISERS SHALL
BE TREX TYPE SYNTHETIC SURFACES).
GUARDRAILS ARE TO BE DESIGNED TO RESIST A 200 LB. CONCENTRATED LOAD ON
THE TOP RAIL AND 50 PSF ON ALL GUARDRAIL INFILL COMPONENTS.
PATIO CONSTRUCTION
1) ALL PATIOS SHALL BE CONSTRUCTED WITH THE FOLLOWING MATERIALS:
PATIO SURFACE: 4" CONCRETE SLAB ON COMPACTED GRAVEL/FILL WITH
EXPOSED AGGREGATE FINISH. SEE FLOOR PLAN FOR CONTROL JOINT
LOCATION.
2) PATIOS SHALL BE CONSTRUCTED AS SHOWN ON LOWER LEVEL FLOOR PLAN
DRAWINGS.
PORCH &DECK CONSTRUCTION
PORCH AND RAISED DECKS
LEVEL 1 COVERED DINING DECK SHALL BE SYNTHETIC WATERPROOF DECK
COATING (SELECTION &COLOR BY OWNER) OVER PRESSURE TREATED
PYLYWOOD OVER PRESSURE TREATED FRAMING WOOD FRAMING. (SEE
STRUCTURAL DRAWINGS FOR DECK FRAMING AND DECK SUPPORT POST
INFORMATION)
ENTRY PORCH, REAR PORCH @LEVEL 1, AND STEPS TO DECKS SHALL BE
SYNTHETIC DECKING MATERIAL (SELECTION BY OWNER) OVER PRESSURE
TREATED WOOD FRAMING. SEE STRUCTURAL DRAWINGS FOR FRAMING
INFORMATION.
LEVEL 1 COVERED DINING DECK SHALL HAVE ATOP -MOUNTED GUARDRAIL
SYSTEM (36"HIGH ABOVE WALKING SURFACE) AND VERTICAL BALUSTERS
SHALL BE PLACED SO THAT A 4" DIAMETER SPHERE WILL NOT PASS
BETWEEN BALUSTERS OR STRINGERS. SEE ELEVATION DRAWINGS AND
DECK DETAILS FOR ADDITIONAL INFORMATION.
BASEMENT PORCH: SEE STRUCTURAL DRAWINGS FOR SLAB THICKNESS &
REINFORCING.
BASEMENT PORCH SHALL BE 4" THICK CONCRETE SLAB.
ALL CONRETE PORCHES, STEPS, WALKWAYS, AND PAVERS SHALL BE
INSTALLED ON GRAVEL BASE OVER COMPACTED SOIL PER STRUCTURAL
ENGINEERING STANDARDS.
FIREBLOCKING
FIREBLOCK CONSTRUCTION
1. INSTALL FIREBLOCKING MADE OF MATERIALS AS ALLOWED BY THE 2015
EDITION OF THE 2015 INTERNATIONAL RESIDENTIAL CODE.
2. PROVIDE FIREBLOCKS AROUND VENTS AND PIPES AND AT VERTICAL
OPENINGS WHERE EXHAUST FAN DUCTS ARE ROUTED TO ROOFTOP
EXHAUST VENTS. PROVIDE STRAPPING AS REQUIRED BY CODE.
3. PROVIDE AND INSTALL FIREBLOCKS AT ALL LOCATIONS IDENTIFIED IN
2012
EDITION OF THE INTERNATIONAL RESIDENTIAL CODE AND AS FOLLOWS:
A) IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS AT THE
CEILING
AND FLOOR LEVELS AT AT 10 FOOT INTERVALS BOTH VERTICAL AND
HORIZONTAL.
B) AT ALL INTERCONNECTIONS BETWEEN CONCEALED VERTICAL AND
HORIZONTAL SPACES SUCH AS OCCUR AT SOFFITS, DROP CEILINGS, AND
COVE CEILINGS.
C) IN CONCEALED SPACES BETWEEN STAIR STRINGERS AT THE TOP AND
BOTTOM OF THE RUN AND BETWEEN STUDS ALONG AND IN LINE WITH THE
RUN OF STAIRS IF THE WALLS UNDER THE STAIRS ARE UNFINISHED.
D) IN OPENINGS AROUND VENTS, PIPES, DUCTS, CHIMNEYS, FIREPLACES
AND
SIMILAR OPENINGS THAT AFFFORD A PASSAGE FOR FIRE AT CEILING AND
FLOOR LEVELS, WITH NONCOMBUSTIBLE MATERIALS.
E) AT OPENINGS BETWEEN ATTIC SPACES AND CHIMNEY CHASES FOR
FACTORY BUILT CHIMNEYS.
HEATING /PLUMBING NOTES
SEE ELECTRICAL PLAN, VENTILATION NOTES, &AIR QUALITY NOTES ON
SHEET A-2.3 FOR ADDITIONAL HVAC INFORMATION AND REQUIREMENTS
GAS FIRED FURNACE HEATING SYSTEM
HEAT WILL BE SUPPLIED BY A GAS FIRED FURNACE W/FRESH AIR INTAKE
AND INTEGRATED WHOLE HOUSE EXHAUST FAN (W/TIMER).
GENERAL CONTRACTOR AND HEATING SUBCONTRACTOR SHALL
COORDINATE ALL DUCT LAYOUT LOCATIONS AND ROUTING OF DUCTS PRIOR
TO FRAMING PROCESS. ALL DUCTWORK IN UNHEATED SPACE SHALL BE
INSULATED DUCT WITH A MIN. RATING OF R-8.
WATER HEATER
A GAS WATER HEATER SHALL BE INSTALLED IN MECHANICAL ROOM. REFER
TO FURNACE &WATER HEATER NOTES FOR INFORMATION
PLUMBING NOISE CONTROL &INSULATION
NOISE CONTROL
ALL PLUMBING SUPPLY AND DRAIN LINES SHALL BE WRAPPED WITH FOAM
PIPE INSULATION. HOT WATER LINES SHALL BE WRAPPED W/ R-5 INSULATION
INTERIOR PLUMBING WALLS SHALL BE INSULATED WITH SOUND BATT
INSULATION.
PLUMBING LINES
PEX SUPPLY (WATER HOT AND COLD), ABS FOR VENT, AND CAST IRON FOR
WASTE THAT RUNS THROUGH LIVING SPACE. ABS WASTE IN BASEMENT
SLAB OR CRAWLSPACE.
DRYER VENTING
DRYER VENTING - W.S.E.C. SEC. M1502.4.5 STATES "WHERE THE EXHAUST DUCT
IS CONCEALED WITHIN THE BUILDING CONSTRUCTION, THE EQUIVALENT
LENGTH OF THE EXHAUST DUCT SHALL BE INDENTIFIED ON A PERMANENT
LABEL OR TAG. THE LABEL OR TAG SHALL BE LOCATED WITHIN 6 FT. OF THE
EXHAUST DUCT CONNECTION".
INSTALL DOWN VENT METAL DRYER BOX BEHIND DRYER AND EXTEND METAL
DUCT TO SIDEWALL OF HOUSE.. SEE UPPER FLOOR PLAN FOR NOTES.
SPRINKLER SYSTEM
THIS RESIDENCE NOT REQUIRED TO BE SPRINKLERED.
INSULATION R-VALUES
PER WASHINGTON STATE ENERGY CODE ,THE INSULATION VALUES ARE R-21 FOR
WALLS, R-38 FOR FLOORS OVER UNHEATED SPACE, AND R-49 IN ATTIC SPACE.
INSULATION CERTIFICATE
BUILDER SHALL COMPLETE AND POST AN "INSULATION CERTIFICATE FOR
RESIDENTIAL CONSTRUCTION" WITHIN 3' OF THE ELECTRICAL PANEL PRIOR TO FINAL
INSPECTION.
GARAGE REQUIREMENTS
OCCUPANCY SEPARATION
OCCUPANCY SEPARATION BETWEEN GARAGE AND LIVING SPACE
5/8" TYPE X G.W.B. (TYP)
CEILINGS: 1 LAYER ON ALL TRUSSES AND TJI's (1 LAYER ON STICK FRAMING @
16" O.C. OR LESS)
WALLS: 1 LAYER ON COMMON WALLS TO ROOF SHEATHING / 1 LAYER ON
WALLS TO SUPPORT PROTECTED CEILINGS
POSTS AND BEAMS: 1 LAYER
DOOR TO LIVING AREA: INSTALL 1-3/8" SOLID CORE WOOD DOOR WITH SELF
CLOSER AND WEATHERSTRIP
GARAGE INSULATION
AT WALLS BETWEEN GARAGE AND HEATED SPACE, INSTALL 2x 6 STUD WALLS
(@ 16" O.C.) W/ R-21 BATT INSULATION. AT CEILINGS BETWEEN GARAGE AND
HEATED AREAS ABOVE, INSTALL R-38 BATT INSULATION BETWEEN SCHEDULED
JOISTS, INSTALL R-10 RIGID INSULATION BELOW SLAB AT HEATED AREAS.
DUCTS IN GARAGE
DUCTS IN THE GARAGE AND DUCTS PENETRATING THE WALLS OR CEILINGS
SEPARATING THE DWELLING FROM THE GARAGE SHALL BE CONSTRUCTED OF
A MINIMUM N0.26 GAGE SHEET STEEL OR OTHER APPROVED MATERIAL AND
SHALL HAVE NO OPENINGS INTO THE GARAGE.
DUCTS IN GARAGE
DUCTS IN THE GARAGE AND DUCTS PENETRATING THE WALLS OR CEILINGS
SEPARATING THE DWELLING FROM THE GARAGE SHALL BE CONSTRUCTED
OF A MINIMUM N0.26 GAGE SHEET STEEL OR OTHER APPROVED MATERIAL
AND SHALL HAVE NO OPENINGS INTO THE GARAGE.
ADDITIONAL INSULATION
REQUIREMENTS
IN ADDITION TO INSULATION REQUIREMENTS NOTED ELSEWHERE IN
THIS SET OF DRAWINGS, THE FOLLOWING REQUIREMENTS FROM THE
2015 W.S.E.C. SHALL BE FOLLOWED:
1) INSULATED HEADERS (ALL VOIDS FILLED TO MIN. R-10.
2) NO WALL STACKS IN EXTERIOR WALL CAVITIES
3) DUCTS IN FLOOR/CEILING ASSEMBLIES SHALL NOT DISPLACE R-30
INSULATION
4) RETURN AIR MUST BE DUCTED (NON -DUCTED JOIST BAYS NOT
ALLOWED).
5) PER SELECTED ENERGY CREDIT OPTION, WINDOWS SHALL HAVE A U
VALUE OF 0.28, R-38 INSULATION II�L�J� R>'D AREAS D AREAS,
R-10 RIGID INSULATION BELOW SL ��,,�{[j�
6) ALL PLUMBING WALLS SHAVE HA,J,(�(��(If�1LATI0N AND ALL
PLUMBING LINES SHALL BE WRAPPF���F��„�(]�IPE INSULATION
DEVELOPMENT SERVICES
DEPARTMENT
Carl J. Colson -Architect
PLLC
23623 20th Ave. W
Bothell, WA 98021
425-806-3703
wwwCarlColsonArchitect. com
Commercial &Residential
Architecture
Evans Residence
Project Address
20018 83rd Ave. W.,
Edmonds, WA 98026
New SFR at 20018 83rd Ave. W (Lot 1 of
PLN20180037)
City of Edmonds Permit #: BLD2020-0250
Project Client 0
Marne &Simon Evans
20020 83rd Ave. W.
Edmonds, WA 98026
Sheet Title
South Buildin
g
Section
7543 REGISTERE
ARCHITECT
G�'� '
CARL J. COLSON
S ATE OF WASHINGTO
ISSUED FOR PERMIT 1-21-2020
Document Set Type:
Revision Schedule
Rev.
# Date Description
1 6-15-2020 Add Window/ Permit Revisions
DRAWING USE NOTIFICATION
This set of drawings is being issued as a Progress or Permit Set of Drawings
and is subject to change and adding of additional information and
drawings as required by review of the Building Department in the
jurisdiction where this project is located.
DO NOT USE THIS DRAWING FOR CONSTRUCTION UNLESS THIS
DRAWING HAS A BUILDING DEPARTMENT "APPROVED" STAMP
APPLIED BY THE BUILDING DEPARTMENT UPON COMPLETION OF
THE PERMIT REVIEW PROCESS.
Do not use this drawing for Bidding or Estimating Purposes unless
authorized by Client. During Construction Phase, the Clients General
Contractor (Builder) or Developer shall be responsible for ensuring that all
Construction Personnel of the General Contractor and all Subcontractors
are supplied with all A�provecl and most current documents.
ARCHITECTURAL COPYRIGHT
This sheet of drawings may not be reproduced in any form without prior
approval of Carl J. Colson -Architect PLLC.
These document, the ideas, and designs incorporated herein as an
instrument of service shall remain the ro ert of Carl .Colson -Architect
p p y 1
PLLC and are solely for the use on this project only. These files, drawings,
ideas, or designs may not be tramsmitted electronically without express
permission of Architect. They are not be used by the client or any other
party or entity on other projects, in whole or part, or as an extension to this
project except by agreement in writing with appropriate financial
compensation to Carl J. Colson -Architect PLLC.
Copyright Carl J. Colson -PLLC, 2019. All rights reserved.
Project Number
Sheet Issue Date
�
05/29/19
� � •
Drawn By
Author
South Building Section
Scale
As indicated
Sheet Plot Dat�/14/2020 7:45:23 PM
www.CarlColsonArchitect.com
For 3fi"- and 42"-Tall Guard Posts
NOTE: THIS DETAIL SHOWS
4x4
As an alternative code -compliant solution for attaching
wood guard posts without the use
FLASHING FOR A SLIDING � Sliding glc>!ss
Dili or pan friashing counter-floshes deck
past
4x4 blocking
oe�kjoist
oft ical hardware and throu h-bolts, the uard osts and the framin elements can be
Yp 9 g p g
GLASS DOOR FRAME. door frarr�e
fl��hin and,�or �rafer-resistive k�nrri:ef,
9
�
fastened with Strong -Drive® SDWS Timber screws. The SDWS Timber screws are code
FLASHING WOULD BE SIMILAR
FOR A STANDARD EXTERIOR
protecting �rcill �el�v►r
'°°�""
re ort listed in IAPMO UES ER-192. The solutions below have been tested and verified for
p
DOOR FRAME Caul k�seci lout between
B„ � �_�
36"-tall guard posts constructed with DFL, HF and SP framing. These solutions have also
fr�Jr� al�d flash) I�g
au�%�sea I�rtt or
5 _
been tested and verified for 42 -tall guard posts constructed with DFL and SP framing only.
smolder 6etweek�
� ��, f���� �,��
Band joist
Carl J. Colson -Architect
'
���� f l� g h t n�
[nominal 2xB) SOWS22BOODB,
designated as
0.220"
SDW5225J)DDB, � �
8" throughout
designated as _
5" throughout 0.75' ;
P L L C
ham —Thread length �
23623 20th Ave. W
�� i �
� � IC fl CIS h J 11g
4x4 blocking
2x blacking Grp.
'�r � Length
'� i
�
4x4 post
4x4 post `.
4x4 post
I
Bothell WA 98021
�'�
Strong -Drive SDWS TIMBER Screw (SDWS22500DBf SDWS22800DB]
r
.
�� - --
-_ =w--- �
a"` �.> a^
5^<, : 5'� 5°�
�
� S��J�
eol CkI I pe IletrCffl�n 5
,� ; -
_
I
Note: For this installation, it is imperative
425-806-3703
through pc�n
', �
��
-
that only approved fasteners are used
CUTTING PRESSURE TREATED WOOD FRAMING
_
a°- a°
8° 8° a"�
� _
a° � and installed per Simpson Strong Tie
wwwCarlColsonArchitect.com
'��
��
ALL CUT ENDS OF PRESSURE TREATED WOOD
�Rimjoist details. Test results have shown that
(nominal 2x8]
Commercial &Residential
�'
JOISTS AND POSTS SHALL BE TREATED WITH
generic fasteners do not provide sufficient
�
� �'
COPPER -GREEN OIL -BASED WOOD CONDITIONER
withdrawal resistance, pull -through
Architecture
-�
%�
(OR SUBSTITUTE AS APPROVED BY OWNER) NO
Plan View Showing Details of Four Connections Using Strong -Drive SDWS Timber
Screws
resistance or shear strength.
� � -
EXCEPTIONS!
(other
connection hardware not shown far clarity)
NOTE: THIS DETAIL DOES NOT
�
'
PRESERVATIVE TREATMENT SHALL BE BRUSHED ON
BEFORE OR DURING THE FRAMING PROCESS
- =
•
Evans
SHOW THE RAISED FOUNDATION
(TYPICAL AT ALL DECK FRAMING)
Dining Porch Guardrail Post Attachment w/
Simpson
Connectors
� � _ ®® "�
_Residence
WALL AT PORCH WHICH IS
'.
����
eaa _ ®�
Pro ect Address
SPECIFIED FOR THIS PROJECT.
.:
a ®s _ ®�
�
THIS DETAIL IS INCLUDED TO _ '
i'u_
_- �-
Wciter-resfsttve
'" �'
20018 83rd Ave. W.�
SHOW THE FLASHING BELOW THE _ � '_
_ i
bor�-lef
as
DOOR SILL '- -`
' �*
F. F �
�' °
Edmonds, WA 98026
SEE PORCH SECTION DRAWING . �
. F
®'
BELOW FOR RAISED FOUNDATION ' r - . '
- - , '
WALL AT PORCH •' ' •
`
- �' -
'
Internal Guard Post Installations Using
New SFR at 20018 83rd Ave. W (Lot 1 of
. ,
- - ,
Strong -Drive SDWS Timber Screws
PLN20180037)
Door Flashing @ Leve11 Covered Porches
City of Edmonds Permit #: BLD2020-0250
Project Client
Marne &Simon Evans
20020 83rd Ave. W.
Edmonds, WA 98026
SCHEDULED ROOF ASSEMBLY, PER SHEET A-4.1 ----__
Sheet Title
2 x 4 VENTED BIRD BLOCK
ROOF TRUSS -SEE STRUCT. DRWGS.
Entr Porch Section
Y
� Plan /Guardrail
o
PRIMED AND PAINTED BEAD BOARD CEILING T �
Po st D etails
_,
�
7543
I
�
___________________
REGISTERE
TRIM @EACH SIDE OF BEAM WRAP
I I
TRIM WRAPPED BEAM @NORTH SIDE OF PORCH �
ARCHITECT
PRIMED &PAINTED 1 x WOOD TRIM
I
i
W/SMOOTH FINISH OVER W.R.B.
I I
�
OVER 1/2" PLYWD. SHEATHING OVER
I I
GT'`
SCHEDULED BEAM.
I I I
�
CARL J. COLSON
PORCH ROOF BEAM, VERIFY SIZE PER
I I
�
SATE OF WASHINGTO
STRUCTURAL DRAWINGS
I I
I I I
i
I I
i
ISSUED FOR PERMIT 1-21-2020
I
Document Set Type:
I I I
STRUCT. POST -- I I
CUTTING PRESSURE TREATED WOOD �
ALL CUT ENDS OF PRESSURE �
Revision Schedule
TREATED WOOD JOISTS AND POSTS
Rev.
I SHALL BE TREATED WITH COPPER- i
I I
GREEN OIL -BASED WOOD i
CONDITIONER (OR SUBSTITUTE AS i
TYPICAL EXTERIOR WALL. SEE SHEET
# Date Description
SCHEDULE ROOFING. SEE
APPROVED BY OWNER) NO i
A-4.1 FOR NOTES
_ =
ROOF PLAN FOR ROOF
5112" I I I
EXCEPTIONS!
1
6-15-2020
Add Window /Permit Revisions
_ —
SLOPE. SEE SHEET A-4.1 FOR
PRESERVATIVE TREATMENT SHALL BE
ROOFING TYPE INFOMATION
I I
BRUSHED ON BEFORE OR DURING i
THE FRAMING PROCESS i
RIPPED PRESSURE TREATED ANCHOR
_ _
-
—�
METAL DRIP EDGE FLASHING
@ALL ROOF EDGES
JOIST MEMBRANE FLASHING
DASHED LINE INDICATES
PORCH POST CENTERLINE
LINE OF STONE VENEER. I i
PLATE TO EXTEND FULL WIDTH OF
FOUNDATION WALL. BRUSH
IDES AND
P.T. 2 x 8 BELOW. SEE GRACE TV718294 9" X 75' VYCOR i ENDS OF CUT ANCHOR PLAATE
I I SEE EXTERIOR I
DETAIL @RIGHT
1 1/2" 1 1/ " 1 1/4"
FLASHING AT TOP OF ALL 2 X 8
BEAMS &ADJACENT RIM
8�� I
I
/
PORCH DECKING OVER ELEVATIONS FOR i
PRESSURE TREATED WOOD I i
NOTE: THIS RAISED FOUNDATION WALL
DRAWING USE NOTIFICATION
LOCATION OF STONE i
2 X 10 PRIMED &PAINTED JOISTS AT DECK PERIMETER. OCCURS ONLY AT PORCH AREAS. SEE
FRAMING. SEE STRUCT. VENEER � i
CEDAR TRIM BOARD @ TURN DOWN FLASHING TAPE i ARCHITECTURAL FOUNDATION PLAN ON
1 x 2 TRIM (WRAPPED) @
DECK EDGE. SEE DETAIL @
AT SIDES OF BEAM
I I
I
DWGS. FOR FRAMING LAYOUT � �
i
SHEET A-2.1 FOR LOCATIONS OF RAISED
This set of drawin s is bein issued as a Pro ress or Permit Set of Drawin s
g g g g
TOP OF COLUMN
RIGHT
I
INSTALL DECK JOIST FLASHING ALUMINUM FLASHING TO I �
FOUNDATION WALLS
and is subject to change and adding of additional information and
PRIMED & PTD. 1 x CEDAR
WRAPPING ROOF SUPPORT BEAM
PAINTED PORCH COLUMN
i i I � 5/4" X 4" PRIMED &PAINTED
� CEDAR TRIM BOARD @DECK
� EDGE. SEE DETAIL @RIGHT
SEE NOTE RI
@ GHT ABOUT
TREATING ENDS OF JOISTS
I I
I I
I
71/2" I I
MEMBRANE (GRACE VYCOR PLUS TUCK UP BENEATH I �
WEATHER RESISTIVE i
FLEXIBLE FLASHING) AT TOPS OF I �
BARRIER, AND OVERLAP P.T. i
ALL JOISTS AND BEAMS AT �
LEDGER BEAM AS SHOWN
SEE SHEET A-4.1 FOR FLOOR ASSEMBLY
INFORMATION
drawings as required by review of the Building Department in the
jurisdiction where this project is located.
DO NOT USE THIS DRAWING FOR CONSTRUCTION UNLESS THIS
DRAWING HAS A BUILDING DEPARTMENT "APPROVED" STAMP
I AND POSTS COVERED PORCHES (TYP) i
LINE OF STRUCTURAL WOOD
POST. SEE STRUCT. DWGS.
SEE STRUCT. I AREA w/DIAGONAL LINES IS
DRWGS. FOR LOCATION OF DECK JOIST
I I
i
2 x 8 P.T. JOIST BEYOND PER PORCH I ��
LIVING ROOM
APPLIED BY THE BUILDING DEPARTMENT UPON COMPLETION OF
FOR SIZE &CONNECTION
P.T. 2 x 8 WOOD BEAM
��
THE PERMIT REVIEW PROCESS.
DETAILS. SEE PLAN DETAIL
FOOTINGS SUPPORT BEAM PER
ATTACHED TO SIDE OF
3/4" I I
STRUCT. DWGS. _
N i
Do not use this drawin for Biddin or Estimatin Pur oses unless
g g g p
FOR LOCATION OF
STRUCT. DRAWINGS TYP .
( )
PORCH JOIST � SEE DETAIL @RIGHT
PORCH COLUMNS
� �
i �
I
I o
authorized by Client. During Construction Phase, the Clients General
STRUCTURAL POST
i �
Contractor (Builder) or Developer shall be responsible for ensuring that all
�
6 x 6 POST PAINTED 1 X WOOD TRIM
�
5/4" X 4" PRIMED &PAINTED CEDAR
TRIM BOARD @DECK EDGE
� o I
I _ °
Q
J ° °
I
a
°
�
Construction Personnel of the General Contractor and all Subcontractors
�
OVER WEATHER RESISTIVE
�
I
�
�d
4 MESH GALV WOVEN 20 GAUGE � ° a=�=°a'
° _ I INSTALL WEATHER RESISTIVE BARRIER
a �a"
are supplied with all A�provecl and most current documents.
ARCHITECTURAL COPYRIGHT
� -- 1x PRIMED (ALL SIDES) & BARRIER OVER 1/2" � .° . I BETWEEN JOIST HANGER AND
2 X 10 PRIMED &PAINTED CEDAR WIRE MESH (W/ 1/4"OPENINGS) TO —_-- - - � -
� � ° � �
� PAINTED CEDAR OVER PLYWOOD OVER PRESSURE I � - � FOUNDATION WALL PRIOR TO HANGING
� TRIM BOARD @DECK EDGE PREVENT RODENTS BELOW PORCH I
WEATHER BARRIER
MEMBRANCE OVER
� � TREATED 6 X 6 POST
o
o o m . ,
JOISTS
(TWP SELLER @ 800-227-1570 OR BY � - <' ° �:e - '' I /
o o
This sheet of drawings may not be reproduced in any form without prior
TREX TYPE DECKING OVER JOIST
STRUCTURAL COLUMN.
=
= � \ � DASHED LINE INDICATES
N � LINE OF 8" DIA. SONOTUBE
P.T. BEAM PER STRUCTRAL
FRAMING DRAWINGS
I
LOCAL SUPPLIER). TURN UP @EDGE P.T. LEDGER BEAM ATTACHED � d`._ A _ ,
OF PORCH AS SHOWN AT LEFT TO FOUNDATION WALL PER I '° "
- _, _ i
� I
approval of Carl J. Colson -Architect PLLC.
These document, the ideas, and designs incorporated herein as an
MEMBRANE FLASHING OVER / P.T.
WOOD FRAMING JOISTS. SEE STRUCT.
ALL CORNERS TO BE MITERED.
T \
r` i r � \� POST PER STRUCTURAL
RODENT SCREEN
_
-
I �
STRUCTURAL DRAWINGS
I
JOIST HANGERS HUNG FROM
instrument of service shall remain the ro ert of Carl Colson -Architect
p p Y 1�
DWGS. FOR FRAMING INFORMATION
T I DRAWINGS
_
- o 0 0 0 0 0
0
0 0 0 � C I
ANCHOR PLATE PER STRUCT. DWGS.
PLLC and are solely for the use on this project only. These files, drawings,
-
—
-'�-�'C�� —
, i
ideas, or designs may not be tramsmitted electronically without express
I
I � PRIMED (ALL SIDES) &
STOP GRAVEL @
O O� DO ODO�O O O�O �ODO�_'
- I
CONC. FOUNDATION WALL PER
permission of Architect. They are not be used by the client or any other
TREX DECK EDGE TRIM OVER
PTD. 2x6 CEDAR COLUMN
PAINTED CEDAR 2 x 10
� ,� �
_
EDGE OF DECK W/ —
l I
� I
STRUCTURAL DRAWINGS
party or entity on other projects, in whole or part, or as an extension to this
TREX RIM BOARD
BASE TRIM W/CHAMFERED
EDGE @TOP
REFER TO STRUCTURAL
� /� NAILED TO P.T. 2 x 8's
� �
�, ` � _ J
BLACK ALUMINUM
LANDSCAPE EDGING
� �
�
� �
�� � � L�� �
�
III III— I "- ,-; . ; � -,
6"GRAVEL OVER FILTER FABRIC � a - _
OVER SOIL— � O O C ° ^" °�
;
- < _ _ ; -
- CAST -IN FOUNDATION WALL CRAWL
�° a SPACE VENT. HOLD BELOW LEDGER
� �
project except by agreement in writing with appropriate financial
compensation to Carl J. Colson -Architect PLLC.
Copyright Carl J. Colson -PLLC, 2019. All rights reserved. O
Project Number
..
I I I III o 0 0 , �<I - BEAM AS SHOWN
DRAWINGS FOR ALL 5/4 X 4 SKIRT BOARD 8" DIAMETER - �� � � -
a
COLUMNSIZES AND PORCH JOIST IS ATTACHED TO CONCRETE POST _ � �O�O�� _ ° - °a � � °
� 9 9
CONNECTION DETAILS
SUPPORT BEAM W/ FACE MOUNT JOIST
HANGERS PER STRUCT. DRWGS. EDGE OF PORCH
(SONOTUBE) OVER —
BURIED CONC.
��_ 1c�_ ��
— — — — —
GALVANIZED FOUNDATION WELL AT
_ , FOUNDATION VENTS (TYP)
�
Sheet Issue Date
AREA BELOW DECK AND FINISH GRADE SHALL �
FOOTING. SEE
�
t <
— —
� I � � � i a;a_ a -°,
a®a- �-a
11/08/18
�
� �
Drawn ey
Author
BE SCREENED. COORDINATE SCREENING ENTRY PORCH COLUMN FRAMING DETAIL STRUCTURAL = � — — � , .a _ � - _, , ,_ 6" GRAV L�����-V. WIRE
DETAIL W/ARCHITECT OR SIZE & — a ° a'- 4 - , a p, MESH AT�OnTQ� QFO�(�NT WELL
Entry Porch Section &Plan /Guardrail Post
RE N1FORCSN
�
— —
� �_ �- °,�
a SEE SHEE��><k4r1H3�Nos
Details
scale
Porch Column Elevation
Entr Porch Section &Column Plan Detail
-
� �� �� �
.. ; a
.a
CONST���j'� '�' �,����R
As indicated
2
��
I
Y
� � �
-
���� � � �
� � �
� � � � � - -
WATERPROOFING OF FOUNDATION
h PI D
S eet of at�i/14/2020 7:45:44 PM
WALL
www.CarlColsonArchitect.com
51/2" 6 x 6 CONTINUOUS POST IN COLUMN .
SEE STRUCT. DRAWINGS
� UPPER PORCH COLUMN BEYOND
I I
COLUMN CENTERLINE
For 36"- and 42"-Tall Guard Posts
II I I
As an alternative code-com lant solution for attachin wood uard osts without the use
P g g p
I I
PRIMED &PAINTED CEDAR 2 x 6 TOP
of typical hardware and through -bolts, the guard posts and the framing elements can be
I CAP W/ E0. SLOPES TO DRAIN TO SIDES
Carl J. Colson -Architect
fastened with Strong-Drive°SDWS Timber screws. The SDWS Timber screws are code
I I
I I I
report listed in IAPMO UES ER-192. The solutions below have been tested and verified for
I I PRIMED &PAINTED CEDAR 2 x 4SUB-RAILING.
PLLC
36"-tall guard posts constructed with DFL, HF and SP framing. These solutions have also
NAIL TO PORCH COLUMN BEYOND
I
23623 20th AVe. W
been tested and verified for 42"-tall guard posts COr1StrUGted Wlth DFL and SP framing Only.
PRIMED &PAINTED CEDAR 1 x 4 EA. SIDE
Bothell, WA 98021
PRIMED &PAINTED CEDAR 2 x 2
0.220°
BALUSTERS SPACED SO TO PREVENT
425-806-3703
�°t' _ �
I I PASSAGE OF 4" DIA. SPHERE. BALUSTER
0.75"
� END -NAILED TO CEDAR 2 x 4 SUB-RAILING
I
� h+�Thread length
wwwCarlColsonArchitect.com
Lergth
Commercial &Residential
I PRIMED &PAINTED CEDAR 4 x 4
Strong -Drive SDWS TIMBER Screw (SDWS22500DB, SDWS22800DB)
I I GUARDRAIL POSTS. SEE FLOOR PLAN
Architecture
FOR LOCATIONS
Note: For this installation, it is imperative
I
that only approved fasteners are used
o
I
DINING PORCH
and installed per Simpson Strong Tie
�''
I I FASTENERS: ALL SCREWS AND NAILS
Evans Residence
details. Test results have shown that
I SHALL BE GALVANIZED
generic fasteners do not provide sufficient
I I
I I
Project Address
withdrawal resistance, pull -through
61/2" I I
20018 83rd Ave. W.,
resistance or shear strength. _
PRIMED &PAINTED CEDAR 1 x 4 EA. SIDE.
1 I I i � CUT TOP SLOPE TO DRAIN AS SHOWN
SLOPE DECK TO EXTERIOR @ 1/4" PER FOOT
Edmonds, WA 98026
��
PRIMED &PAINTED CEDAR 1 x 4 TO WRAP
WATERPROOF DECK COATING ON PRESSURE TREATED
~`
a � ®e ®�
a
BOTTOM OF POST
3/4" PLYWOOD DECKING
rd
New SFR at 20018 83 Ave. W (Lot 1 of
,
I I,\
• ®� - ®°
'� `
PTD. METAL DRIP
= I SLOPE DECK 1/4" PER FT.
PLN20180037)
®®
EDGE FLASHING
�
City of Edmonds Permit #: BLD2020-0250
� ,
'a a ®
®
____-- = BOLT 4 x 4 GUARDRAIL POST TO 2 x 10 BLOCKING
PORCH FLOOR JOISTS PER STRUCTURAL DRAWINGS
Project Client 1�
Internal Guard Post Installations Using
1 x 4 CEDAR TRIM
& RIM JOIST (PER GUARDRAIL POST ANCHOR
6 x 6 DETAIL ON THIS SHEET) BETWEEN ADJACENT
Marne &Simon Evans
OVER 2 x 10 CEDAR
POST JOISTS @GUARDRAIL POST LOCATIONS.
20020 83rd Ave. W.
RIM JOIST, PER
Edmonds, WA 98026
4xa post
dxd blocking Deck joist
STRUCTURAL DRAWINGS
=_____ =
Sheet Title
� 1 �, �` THESE 2 BLOCKS OCCUR ONLY AT LEVEL 1 TOP PLATE LEVEL
��
�8"
BEAM PER STRUCT. DRWGS.
� GUARDRAIL POST LOCATIONS FOR POST
ANCHORING PURPOSES
2 x 6 CEILING JOIST FRAMING @ 16" O.C. �'
U er Porch 8�
g
�
1 x 6 CEDAR TRIM
5 3/4"
pp
5"
2 x 6 CEILING JOISTS @ 24" O.C.
Band joist
� 1 x 2 TRIM @PORCH PERIMETER
VENTED PORCH CEILING
Interior Details
{nominal 2x8} SDWS22800DB,
PTD. METAL DRIP
I 3/4"WIDE SCREENED VENT @OUTSIDE
�
\� PRIMED AND PAINTED TONGUE AND GROOVED BOARDS
designated as 5DW52250pD8,
EDGE FLASHING.
PERIMETER OF PORCH
8" throughout designated as
1 x 3 @OUTSIDE PERIMETER OF PORCH
� BOTTOM OF BEAM WRAP @SAME ELEVATION @ALL SIDES
5" throughout
SEE PORCH COLUMN WRAP
I
OF UPPER PORCH
4x4 blocking 2x blocking typ. �
DETAIL FOR MATERIAL OVER
SUPPORT POST BEYOND EL 1
7543
dxd post 1 4x4 past dx4 past TOP PLATE &CUNDERSIDE OF G RDER
` �5"—+I
8"< �$. 5 <� � 5 5 C
LEVEL 1 PORCH COLUMN
I TRUSS BELOW OVERHANGING MASTER
LOWER LEVEL PORCH
REGISTERE
BEYOND. SEE COLUMN DETAIL BEDROOM WEST WALL. REFER TO
ON SHEET A-4.2
STRUCTURAL DRAWINGS
ARCHITECT
�� =� �.�` I '-�_—�" I
8"
6 x 6 CONTINUOUS POST IN COLUMN .
,
8° 8" 8° 8" 8"
�'`
SEE STRUCT. DRAWINGS
GT'`
Rim joist
{nominal2x8}
I
CARL J. COLSON
I I g
�, Dinin Porch Guardrail
SATE OF WASHINGTO
Plan View Showing Details of Four Connections Using Strong -Drive SDWS Timber Screws
� � �
1 �-0"
1 1 /2" = 1
(other connection hardware not shown for clarity)
ISSUED FOR PERMIT 1-21-2020
Dining Porch Guardrail Post Attachment w/ Simpson Connectors
Document Set Type:
STAIR REQUIREMENTS
Revision Schedule
THE STAIR DRAWING BELOW IS USED TO ILLUSTRATE BUILDING CODE
Rev.
REQUIREMENTS FOR STAIRS.
# Date Description
CONTRACTOR SHALL COORDINATE SELECTION OF STAIR CONSTRUCTION
& RAILINGS OR HALF -WALLS WITH OWNER PRIOR TO FRAMING STAIRS
1
6-15-2020
Add Window /Permit Revisions
3�" min to to-p of guard
Provide artificial ligh#
source per R30.6
2'-0" / 2'-0"
'
Graspable Flandrail 7 tJd" rnin,
DRAWING USE NOTIFICATION
to- 2" max.. Handrail ends shall
be returned or shall terrtinate
This set of drawings is being issued as a Progress or Permit Set of Drawings
at a newel post or safety -------_
and is subject to change and adding of additional information and
THIS WALL OFFSET 12"
i terminals.
drawings as required by review of the Building Department in the
FROM MAIN WALL
+
jurisdiction where this project is located.
DO NOT USE THIS DRAWING FOR CONSTRUCTION UNLESS THIS
r �
� �
THESE TRIM DETAILS ARE TO BE USED ON:
1 ALL LEVEL 1 CASED OPENINGS @
�
� Intermediate rails
DRAWING HAS A BUILDING DEPARTMENT "APPROVED" STAMP
� �
i
OPTIONAL LOCATION
LIVING ROOM AND IN HALLWAY ADJACENT
r spaced so- that a
�
APPLIED BY THE BUILDING DEPARTMENT UPON COMPLETION OF
THE PERMIT REVIEW PROCESS.
4" s here shall not
FOR TV. COORDINATE w/ - p
� TO LEVEL 1 BATHROOM AND ELEVATOR � pass tluough
�
OWNER
2), ALL INTERIOR WINDOWS
�
Do not use this drawing for Bidding or Estimating Purposes unless
�
WOOD MANTEL &CORBELS.
� ALL INTERIOR DOORS �
� .} �
authorized by Client. During Construction Phase, the Clients General
SELECTION BY OWNER
(SEE DETAIL PHOTO ABOVE) z
� � �`
Contractor Builder or Develo er shall be res onsible for ensurin that all
{ } p p g
�
�
� '
Construction Personnel of the General Contractor and all Subcontractors
CASED OPENING, DOOR &WINDOW INTERIOR TRIM o
�
are supplied with all A�provecl and most current documents.
(4) DECORATIVE WOOD
ALL DOOR &WINDOW INTERIOR TRIM SHALL BE �
PRIMED AND PAINTED MDF �
� '�
�
ARCHITECTURAL COPYRIGHT
SUPPORT CORBELS
�
�
_
�
This sheet of drawings may not be reproduced in any form without prior
-
DOOR &WINDOW INTERIOR TRIM �
'� `~ a
'�
approval of Carl J. Colson -Architect PLLC.
_ _
�T
STONE VENEER. SELECTION
ALL DOOR &WINDOW INTERIOR TRIM SHALL BE z
� "
�
These document, the ideas, and desi ns incor orated herein as an
�� -
BY OWNER
PRIMED AND PAINTED MDF. COORDINATE INTERIOR �
DOOR HEAD TRIM AND INTERIOR WINDOW HEAD �
_
� �
instrument of service shall remain the property of Carl J. Colson -Architect
— `�`' �
2"THICK CAST CONCRETE
TRIM wl OWNER PRIOR TO INSTALLATION OF �
� stair Guard Min. ��", -
PLLC and are solely for the use on this project only. These files, drawings,
— =
RAISED HEARTH
INTERIOR TRIM
Handrail height above 9 i7" rnin.
ideas, or designs may not be tramsmitted electronically without express
l —� -
Stall 34" t0 ��" tea% 'ti -
permission of Architect. They are not be used by the client or any other
�
� _ ,� -
PTD. MDF BASE TRIM
BASEBOARD
party or entity on other projects, in whole or part, or as an extension to this
�
BASEBOARD TRIM SELECTION BY OWNER. TYPICAL
� � ;•' to 7 '1:' nose
project except by agreement in writing with appropriate financial
i
� LINE OF FINISH FLOOR
i
�
AT ALL INTERIOR WALLS
,.�� ar min, 7 i" tread
A 4"sphere cannot �, •'• -
through the
compensation to Carl J. Colson -Architect PLLC.
Copyright Carl Colson 2019. All O
pass _ _ �
J. -PLLC, rights reserved.
space between _ _ _
N
treads' .-'� Rise�un-rail opening
Project Number
SEE FLOOR PLAN FOR DIMENSIONS
'
WINDOW /DOOR /CASED OPENINGS TRIM DETAILS
1 spaced so thata 6"sphere
���� ���' ������� shallnatpassmrough
Sheet Issue Date
12/11/18
r w
FIREPLACE ELEVATION Install.<_"gypsum
�
�
,/-, Living Room Fireplace
card o-n walls and
RESU �ilings of all useable
G�lard and handrail to p
s ace under
DrawnB y
��
sustain 2D0 Ib. load Jun 15 202�terar
a'rs'
Author
Upper Porch &Interior Details
\ i 1 /2 tt = 1 t-O tt
� �
STAIR REQUIREMENTS
SCale
CITY OF EDMONDS
Guard balusters tD DEVELOPMENT SERVICES
DEPARTMENT
As indicated
Sheet PlotDat�i/14/2020 7:46:04 PM
sustain �0 pSf load
www.CarlColsonArchitect.com
WINDOW FLASHING DETAILS
Step 1: Prepare the WR6 at the rough
opening: insta I! a sma I! section of house
wra p below the si II (referred to as an
"apron"}; alternatively, install self-adhesive
pan flashing with split backing (where the
release paper backing can be removed incre-
mentally) to seal to the house wrap later.
Step 2: Ir7stallpar? flashing: cover the rough
silt and extend ❑nto the face of the wai f
VVi�B.
Step 3: Instal! the window: according t❑
manufacturer instructions.
Step 4: Instal! the jamb flashing: aver
window flange and pan flashing and extend
above the head flange.
Step S: Instal! the head flashing: aver and
beyond the jamb flashing {and aver the win-
dowdrip cap if installed).
Step G: Integrate the WR6: Install house
wrap shingle -fashion, integrated with the
apron, and seal house wrap at jambs and
head using sealant (beneath the house wrap)
or construction tape.
HEAD FLASHING NOTE: SEE NOTE BELOW
DRAWING FOR INSTALLATION OF METAL
HEAD FLASHING @THIS AREA
WEATHER RESISTIVE BARRIER
HYDROGAP DRAINABLE HOUSEWRAP
(BENJAMIN OBDYKE) W/BENJAMIN
OBDYKE HYDROFLASH®GP SILL /
PENETRATION FLASHING AND BENJAM
OBDYKE HYDROCORNER SILL FLASHIN(
HEAD FLASHING NOTE:
AT WINDOW HEAD METAL DRIP
FLASHING :INSTALL METAL HEAD
FLASHING @WINDOWS &
EXTERIOR DOORS PER THE
DETAIL BELOW.
Hausewrap
Rigid cap flashing
Flashing tape �
over head trim
10° to 15°
slope �
Flashing '�
tape '
overtop
window
flange j
Head trim
Flashing talae
aver side
window flange
- _.
r �_
�-
\il, A�J
Ufa -in. gap
beneath
siding
�LINSTALL BENJAM N OBDYKE
HYDROCORNER SILL FLASHING @ALL WINDOW SILL
CORNERS.
INSTALL BENJAMIN OBDYKE HYDROFLASHO GP SILL /
PENETRATION FLASHING OVER CORNER SHIELD, AS EXTRA
PREVENTION FOR LEAKS @SILL CORNERS
WINDOW TYPE LEGEND
SINGLE HUNG WINDOWS
THESE DIMENSIONS
REPRESENT THE ROUGH
OPENINGS FOR WINDOW
TYPES. COORDINATE W/
WINDOW MANUFACTURER
FOR ACTUAL WINDOW
FRAME SIZE (TYP @ALL
WINDOWS)
MULLED WINDOWS
REFER TO FLOOR PLANS
FOR LOCATIONS OF
WINDOWS THAT ARE
MULLED TOGETHER
A
3060
SINGLE HUNG
� 3 0 �
CASEMENT WINDOWS
I
2638
CASEMENT
2'-6"
M
NOTE THAT TWO OF THESE
WINDOWS ARE MULLED TOGETHER
@ THE KITCHEN SINK AREA
DOOR TYPE LEGEND
DOOR HARDWARE
ALL DOORS TO HAVE
LEVER STYLE HARDWARE
W/ANTIQUE PEWTER OR
ANTIQUE BRONZE FINISH.
ALL DOOR HINGES &
LOCKS TO MATCH LEVER
FINISH
DOOR. BASE. &TRIM
PAINTING
ALL DOORS, BASE, DOOR
&WINDOW TRIM TO BE
PRIMED &PAINTED W/
ENAMEL PAINT -COLOR
SELECTION BY OWNER
PTD. SOLID CORE WOOD OR
FIBERGLASS DOOR (SELECTION
BY OWNER) W/SECURITY LOCK &
WEATHERSTRIPPING. SEE PLAN
& SCHEDULE FOR SIZE &SWING
J
1
EXTERIOR TO ENTRY
COORDINATE W/WINDOW MANUFACTURER FOR ACTUAL WINDOW
FRAME SIZE &ROUGH OPENING DIMENSIONS (TYP @ALL WINDOWS)
B C D E
3050 2650 2846 2646
SINGLE HUNG SINGLE HUNG SINGLE HUNG SINGLE HUNG
3'-0" � 3'-0" � � 2'-8" � �� 2'-6° ��
.�
FIXED WINDOWS
J
2027
FIXED WINDOW
2'-0"
M
N
SKYLIGHTS
K
2020
SKYLIGHT
L
2036
SKYLIGHT
DOUBLE GLAZED SKYLIGHTS ON
RAISED CURB (w/METAL
FLASHING). DIMENSIONS SHOWN
ARE APPROXIMATE.
INSTALL JAMSILL GUARD @ALL WINDOWS AND AT EXTERIOR DOORS. COORDINATE INSTALLATION OF
AMSILL GUARD WITH FLASHING MEMBRANE PER MANUFACTURERS INSTRUCTIONS AND REQUIREMENTS
2 3
GARAGE TO EXTERIOR HOUSE TO GARAGE
1 (@ SIDE OF GARAGE)
PTD. INSULATED HOLLOW METAL OR
FIBERGLASS DOOR (SELECTION BY
OWNER) W/SECURITY LOCK &
WEATHERSTRIPPING. SEE PLAN &
SCHEDULE FOR SIZE &SWING
n
F
2640
SINGLE HUNG
�� 2' - 6"
0
WINDOW &DOOR TRIM NOTES
EXTERIOR TRIM
DOOR &WINDOW EXTERIOR TRIM
ALL DOOR &WINDOW EXTERIOR TRIM
SHALL BE PRIMED AND PAINTED CEDAR
- PTD. WOOD TRIM &METAL FLASHING
@ WINDOW TRIM HEAD. TRIM
SELECTION BY OWNER
\
/
\
/
X
/
\
/
\
/
\
4
INTERIOR
1
' SEE BLOCKING NOTE IN WINDOW
GENERAL NOTES
�'— 5/4x6 PTD. WD. TRIM @HEAD
SCHEDULED WINDOW OPENING
5/4x4 PTD. WD. TRIM @SIDE JAMB
2x PTD. CEDAR SILL W/SLOPE
1-1/2" OVERHANG ON SILL
5/4x4 PTD. WD. TRIM @BELOW SILL
PTD. SOLID CORE WOOD DOOR W/ PTD. SOLID CORE WD.
CLOSER, SECURITY LOCK & DOOR W/PRIVACY LOCK
WEATHERSTRIPPING. SEE PLAN & @BEDROOM
SCHEDULE FOR SIZE &SWING SEE PLAN &SCHEDULE
SAFETY GLASS AT DOOR SIDELITES FOR SIZE &SWING
G
2638
SINGLE HUNG
2'-6"
H
2630
SINGLE HUNG
� 2'-6"
0
INTERIOR TRIM DOOR &WINDOW INTERIOR TRIM
DOOR &WINDOW INTERIOR TRIM 1) COORDINATE ALL INTERIOR
ALL DOOR &WINDOW INTERIOR TRIM DOOR &WINDOW FINISHES WITH
SHALL BE PRIMED AND PAINTED MDF OWNER.
— COORD. TRIM w/ OWNER 2) AT DOORS &WINDOWS WITH
�� INTERIOR FINISH THAT IS TO BE
5
INTERIOR TO COVERED PORCHES
\
/
\
/
\
/
\
/
X
/\
/
\
/
\
F'HII"S rlCStl"SIaLHJJ rl"StlVl�l-I UVVI"SJ (VV/
DBL. SAFETY GLASS & MINI -BLINDS
BETWEEN GLASS) SECURITY LOCK,
DEADBOLT, &WEATHERSTRIPPING.
SEE PLAN &SCHEDULE FOR SIZE &SWING
�- SEE BLOCKING NOTE IN WINDOW
STAINED WOOD, THE TRIM
GENERAL NOTES
SHALL BE STAINED WOOD -
1 x6 PTD. WD. TRIM w/CROWN
SPECIES TO MATCH WOOD ON
MOLDING &CAP @HEAD
INTERIOR OF WINDOW OR DOOR.
SCHEDULED WINDOW OPENING
3) AT DOORS &WINDOWS WITH
INTERIOR FINISH THAT IS TO BE
1x4 PTD. WD. TRIM @SIDE CASING &
PAINTED, THE TRIM SHALL BE
JAMBS
PRIMED AND PAINTED MDF
1x PTD. WD. SILL
1"OVERHANG ON SILL
1x4 PTD. WD. TRIM @BELOW SILL
6
GARAGE DOOR
9' x 8' OVERHEAD CARRIAGE -STYLE INSULATED METAL
GARAGE DOOR W/AUTOMATIC CLOSER.
CHAMBERLAIN B730/WD962 GARAGE DOOR OPENER
ULTRA -QUIET BELT DRIVE, 3/4 HPS WITH BATTERY BACKUP
Window Schedule
LABEL
QTY.
WIDTH
HEIGHT
AREA
TYPE
GLAZING
U-VALUE
COMMENTS
A 8 3' - 0" 6' - 0" 144 SF Single Hung_ Insulated Glass 0.28
B 11 3' - 0" 5' - 0" 165 SF Single Hung Insulated Glass 0.28
C 4 2' - 8" 5' - 0" 53 SF Single Hung_ Insulated Glass 0.28
D
1
2' - 8"
4' - 6"
12 SF
Single Hung_
Insulated Glass
0.28
E
2
2' - 6"
4' - 6"
23 SF
Single Hung
Insulated Glass
0.28
F
6
2' - 6"
4' - 0"
60 SF
Single Hung
Insulated Glass
0.28
G
3
2' - 6"
3' - 8"
28 SF
Single Hung
Insulated Glass
0.28
H 1
1
2' - 6"
3' - 0"
8 SF
Single Hung
Insulated Glass
0.28
I
6
2' - 6"
3' - 8"
55 SF
Casement
Insulated Glass
0.28
J
2
2' - 0"
2' - 3"
9 SF
Fixed
Insulated Glass
0.28
K
1
2' - 0"
2' - 0"
4 SF
Skylight
Insulated Glass
L 1 2'-0" 3'-0" 6SF Skylight
Grand total 566 SF
WINDOW HEAD
CEDAR SIDING
BUILDING PAPER
PLYWOOD SHEATHING
METAL FLASHING
BATT INSULATION (R-21)
(1) LAYER OF 1/2" GWB
FLASHING MEMBRANE PER
APPLICATION DETAIL
HEADER PER STRUCTURAL DRAWINGS
5/4 x 6 PRIMED &PAINTED CEDAR
WOOD TRIM W/ DRIP EDGE
INDOW JAMB
CEDAR SIDING
it BUILDING PAPER
PLYWOOD SHEATHING
SEALANT @JOINT
BAIT INSULATION (R-21)
N
(1) LAYER OF 1/2"GWB
5/4 x 6 PRIMED &PAINTED
CEDAR WOOD TRIM
FLASHING MEMBRANE PER
I APPLICATION DETAIL
PAINTED MDF CASING &TRIM
,emu VINYL WINDOW -SEE WINDOW
VINYL WINDOW -SEE WINDOW a SCHEDULE FOR TYPE
SCHEDULE FOR TYPE
LINE OF CEDAR SILL BELOW
METAL FLASHING
Window etails Head -Jamb -Sill
21 ��
2
WINDOW GENERAL NOTES
1. CONTRACTOR SHALL VERIFY ALL WINDOW QUANTITIES AND SIZES BEFORE
ORDERING
2. ALL WINDOWS SHALL BE VINYL WINDOWS WITH DOUBLE GLAZING (1/2"MIN.
AIR SPACE)
3. ALL OPERABLE WINDOWS SHALL HAVE INSECT SCREENS.
WINDOW SERIES
ALL WINDOWS SHALL BE MILGARD VINYL WINDOWS (OR AS SELECTED BY
OWNER) WITH LOW-E /CLEAR GLASS (W/ARGON) WITH A MIN. U VALUE OF 0.28.
SAFETY GLAZING
ALL GLASS LOCATED IN AN AREA WHICH THE 2015 INTERNATIONAL
RESIDENTIAL CODE CONSIDERS HAZARDOUS SHALL BE SAFETY GLAZING.
THESE INCLUDE:
A.) ALL GLAZING IN DOORS AND GLAZING IN ANY OPENING ADJACENT TO A
DOOR WITHIN A 24" ARC OF EITHER VERTICAL EDGE OF THE DOOR IN A CLOSED
POSITION AND WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING IS LESS
THAN 60"ABOVE THE WALKING SURFACE.
B.) TUB /SHOWER ENCLOSURES.
EGRESS WINDOWS
INSTALL MEMBRANE
ALL SLEEPING ROOMS ARE REQUIRED TO HAVE EGRESS WINDOWS. THE
FLASHING PER APPLICATION
WINDOWS SHALL HAVE A MINIMUM NET CLEAR OPENABLE AREA OF 5.7 SQUARE
DETAIL PRIOR TO AND
FEET. THE MIN. NET CLEAR OPENABLE HEIGHT DIMENSION SHALL BE 24"AND
DURING WINDOW
INSTALLATION
THE MIN. NET CLEAR OPENABLE WIDTH DIMENSION SHALL BE 20". ALL EXIT
VINYL WINDOW -SEE WINDOW
WINDOWS SHALL HAVE SILLS NO HIGHER THAN 44"ABOVE THE FINISH FLOOR.
SCHEDULE FOR TYPE
WINDOW SUPPLIER SHALL VERIFY ALL EGRESS WINDOWS MEET EGRESS
PTD. MDF SILL
REQUIREMENTS BEFORE ACCEPTING ORDER FROM CONTRACTOR.
BLOCKING AT WINDOWS
SEALANT &BACKER ROD
PROVIDE BLOCKING @EACH END OF WINDOW HEADERS FOR 1 STUD SPACE TO
2x PRIMED &PAINTED CEDAR
ACT AS BACKING FOR INSTALLATION OF VALANCES /CURTAIN ROD ASSEMBLIES
SILL W/SLOPED TOP
5/4 x 4 PAINTED CEDAR
WINDOW SILLGUARD &EXTERIOR DOORSILLGUARD /FLASHING INSTALLATION
WOOD TRIM W/ DRIP EDGE
CONTRACTOR SHALL INSTALL ALL WINDOWS PER MANUFACTURERS
(1) LAYER OF 1/2"GWB
INSTALLATION INSTRUCTIONS. PRIOR TO INSTALLING WINDOW IN ROUGH
OPENING, CONTRACTOR SHALL INSTALL "JAMSILL GUARD" (AVAILABLE AT
BAIT INSULATION (R-21)
PELLA NORTHWEST IN BELLEVUE 425-455-5550 OR wwwJAMSILL.COM) or
PLYWOOD SHEATHING
"SURESILL" WHICH ARE VINYL WINDOW OR DOOR SILL DAMS TO PREVENT
WATER FROM ENTERING WALL CAVITY (INSTALL PER MANUFACTURERS
INSTRUCTIONS) CONTRACTOR SHALL THEN INSTALL WINDOW WRAP FLASHING
METAL FLASHING PER WINDOW WRAP DETAIL ON T WINDOWS SHALL HAVE METAL
BUILDING PAPER DRIP FLASHING INSTALLED AT H���.
PAINTED CEDAR OR ALL WINDOWS SHALL HAVE META�jiIR€aL�i��G AT WINDOW HEADS.
HARDI-PLANK SIDING
CITY OF EDMONDS
NOTE: ALL CEDAR HEADS, SILLS, AND JAMB FENESTRATION CERTIFICATIONDEVE o PnRNMEIEVRvlces
TRIM SHALL BE PRE -PRIMED AT ALL SIDES ALL NEW FENESTRATIONS SHALL BE NFRC CERTIFIED.
PRIOR TO INSTALLATION - NO EXCEPTIONS
Carl J. Colson -Architect
PLLC
23623 20th Ave. W
Bothell, WA 98021
425-806-3703
wwwCarlColsonArchitect. com
Commercial &Residential
Architecture
Evans Residence
Project Address
20018 83rd Ave. W.,
Edmonds, WA 98026
New SFR at 20018 83rd Ave. W (Lot 1 of
PLN20180037)
City of Edmonds Permit #: BLD2020-0250
Project Client
Marne &Simon Evans
20020 83rd Ave. W.
Edmonds, WA 98026
Sheet Title
Window Le end �
g
Notes
7543 REGISTERE
ARCHITECT
��'` '
CARL J. COLSON
S ATE OF WASHINGTO
ISSUED FOR PERMIT 1-21-2020
Document Set Tvne:
Revision Schedule
Rev.
# Date Description
1 6-15-2020 Add Window /Permit Revisions
DRAWING USE NOTIFICATION
This set of drawings is being issued as a Progress or Permit Set of Drawings
and is subject to change and adding of additional information and
drawings as required by review of the Building Department in the
jurisdiction where this project is located.
DO NOT USE THIS DRAWING FOR CONSTRUCTION UNLESS THIS
DRAWING HAS A BUILDING DEPARTMENT "APPROVED" STAMP
APPLIED BY THE BUILDING DEPARTMENT UPON COMPLETION OF
THE PERMIT REVIEW PROCESS.
Do not use this drawing for Bidding or Estimating Purposes unless
authorized by Client. During Construction Phase, the Clients General
Contractor (Builder) or Developer shall be responsible for ensuring that all
Construction Personnel of the General Contractor and all Subcontractors
are supplied with all AppYOUCGi and most current documents.
ARCHITECTURAL COPYRIGHT
This sheet of drawings may not be reproduced in any form without prior
approval of Carl J. Colson -Architect PLLC.
These document, the ideas, and designs incorporated herein as an
instrument of service shall remain the property of Carl J. Colson -Architect
PLLC and are solely for the use on this project only. These files, drawings,
ideas, or designs may not be tramsmitted electronically without express
permission of Architect. They are not be used by the client or any other
party or entity on other projects, in whole or part, or as an extension to this
project except by agreement in writing with appropriate financial
compensation to Carl J. Colson -Architect PLLC.
Copyright Carl J. Colson -PLLC, 2019. All rights reserved.
Project Number
Sheet Issue Date
�
07/27/18
� � •
Drawn By
Author
Window Legend &Notes
Scale
As indicated
Sheet Plot Dat�/14/2020 7:47:25 PM
www.CarlColsonArchitect.com
ENERGY CODE CERTIFICATE
EVANS RESIDENCE HEATING SYSTEM SIZE
EVANS RESIDENCE GLAZING SCHEDULE
PRESCRIPTIVE ENERGY CODE CREDITS
COMPLIANCE CHART
COMPLIANCE CERTIFICATE: PART OF THE WSEC. ALL
NEW RESIDENCES ARE REQUIRED TO POST THIS
CERTIFICATE WITHIN 3 FEET OF THE ELECTRICAL
SUPPLY PANEL.
CERTIFICATE MUST BE COMPLETELY FILLED OUT AND
POSTED AT TIME OF FINAL INSPECTION. THIS
REQUIREMENT IS THE RESPONSIBILITY OF THE BUILDER
�'ru�icrty .lciclre+,�s:
�UrlililirirlCil H�lour Arra 1?:rt4'� � rt
Builder ur regisfcr�d dcsigrt praf��sitrni�ll
,Si�rrufur•e':
R� Vu�ues
C:eili��: vaultrd R-! Fli�rirs: L�V�f UncandltlailCd 5i1iiCC It -
Attic R- Slab nn �Tade tloc;r R-
1'Yalls: AbaV� grade R- Roars: R-
Below•, exl. F�- R-
�.'-f'ett•}r�r•.s ei►i�l,€ffCr'L'
NRFC rating {or) �4irsd�rws U- SHGC� PIA
Qct'nultrrttlrtgtnraN�,�rnnr�'st:c2orat Skylights lI- �HGC- N}�1
�il�}�N-��rrr. � f)�ilfrlJi{�'J �'rlrll� �i�/flr. � �'r'Pia'�r.0
]�fr?erfi►��;, C'f�rrl�r�g dQ: 13f���.xiit Htrf f l ufcrr
Sti StE'm
T4� Ix
I;Lt'lclency
He.3ting
�:i 3i111 I1�
rillVv
11�u�f � RrfiJdil�; Air l.r�uirn�.�
All tjUCtS c4c HVAC 1CS condltl4ned space � yC5 � no) 11751IISiion �-
hir handler pracsctit (y'ca f t]D )
Test Target CFM�.SPa Test Result �F'M�w25Pa
Suiltliug air Itakagc fa�guE. ACHsr, �� :�.0 - TcSlcLl lcakrrgc. ACi�«y -
Dn�ite Rcrrer��abfe Excr�p Electric Porter �y'stcm
system tyjpr: kat�cd annual generation 1(+,tiwlt
31
4
5
s
10 I
11
12
13
15
ib
17
14
24
22
23
24
25
27
2d
�' 4
3U
31
32
34
35
.36
37
3B
41
42
43
45
�s
��
4$
54
st
52
S3
58
54
b2
��
��
��
Project trrtorrrratiorr Corrtaet trztormatror7
Evans Residence Carl jColson - Archi#ect PELC
2442}{ 83rd Ave W 23623 24th Ave W, Bothell, WA 98421
Edmonds, 1+VA 98426 d25-B46-3743 Car![�rCarlColsanArchitect.corn
Hea#ing System Type: Q All other s�r�t�,s � Heat PumF
TD see detailed rrrstruetiorrs for each seetiorr, place your cursor oil the r�rord "tnstructiorrs ".
f]esign TemperattJre
Instructior�� Design Temperature difference (.�T} 4fi
Edmonds � =:�
� T = indoor (70 degrees} - Outdoor �esrgr: Temp
Area of Building
Conditioned Floor Area
Instrnctior,� Conditioned Floor Area {sq ft)
Average Ceiling Height
Instractian� Average Ceiling Height {ft}
Glazing and avors
Instraction�
LJ-0.28
SI[�ligh#s#s ��J
Instruetion�
Insulation
Attic
� R�9
Single Rafter ar Joist Vaulted Ceilings
Irr3truc:iur� � � R-38Vented
Above Grade Walls (see Figerre 91 J
Instrnctian�
R-z1 Intermediate
Floors
Instruction
R-38 �
Below Grade Walls (see Frgrrre rl
Instruction
R-2t Interior +
,�
2, J0�
Conditioned Volume
8_�
24:71 a
U-Factor
Area =
UA
o.2sa
709
198.52
U-Factor
Area =
UA
a �a
®
2.00
U-Factor
}C Area =
UA
d.026
1,4b7
38.14
U-Factor
?C Area
UA
i].i727
359
9.09
U-Factor
Area
UA
o.o��
2..919
1S3.4+3
U-Factor
X Area
UA
0_a25
2,276
5B_90
U-Factor
�L Area
UA
0_a42
599
25_t0
Slab Below Grade F� r F F ct X L th UA
� ,1Nintio�, �kplight attd Door �chedtile
2 Prv�eet �nrrarrra�trvrr
3 ESrans Residence
4 2002 83rd Ave U'd
5 Edmonds. '4°�A 98028
7
8� � Ref. U-factor
� 'E�cempt SSnr'll7ging Daar f2� sq ft mix.:;
1� '' Exempt Glazed Fel7estratian � 15 sq. ft max. ;
C�ntaet �r�fvrmatrvr�
Carl J Calsal7 -Architect PLLC
�
238�3 20th Aire UV Bothell DNA 98021
���-���-3?03 Carl ��rI�aIS417�+.rchltect.Cam
1Nidth Hei�-It
Qt.� Feet Ir�'r. Feet Ir�r
,area
UA
1 3 �� �
1 3 .� 5 -
'4h4f S E
0 4 8
rV��l,tlf
o.�s
tt
,�
�3 1lertical Fenestration ��filydov+r� alyd dovrs�
14 � Component
15 ! Descrir�#ion � Ref. � U-facto
1f� T;r e A. Sin le Hun ��findoth;
i��lantlf
0 28
17 � T r e B Sin le Hun U�rindo}�r
i�vlantlf
0 28
18 T e C Sill le H�In b'�,'inda�•
i�Vlallllf
0.28
;9 T e D Sin le Htln ';'�finda}�r
i�vlantlf
0.�8
�� T e E Sin le Hun b�inde��
i�V�antlf
0.28
�1 T e F Sin le Hun UUindo}n,�
i�vlantlf
0.28
�2 T r e � Sin le Hun lNindot,v
i�V�antlf
0_�8
�3
1 T r e H Sin le H�In �°,finda7�;
i�Vlal7tlf
0.�8
��
T;r e I Casement '4°�`indo�5,
i��lantlf
0 28
�5
T e J Fitted 4°Jindov'�
i�v�antlf
0 28
�h
T e R Sktirli ht
'4n�SE
0.50
��
��
Entry Daar Entr r 1�esiti�tlle
'��lSE
0 46
��_, Daar Fram h�lud Room to Sara e
',�lSE
0 48
3U Doors from Odra eta Pw9ech Roam
V'JSE
0.�6
3� French Doors from Dinin to Exterior
SE
0.70
�2 Frel7ch Dears from Rec Raam to Exterior
rSE
0.7p
33
57
'4°didth Hei�-It
Qt � Feet Ir�� Feet I��I-
8
3
��
�
o
,�
�
��
�
�
2
$
5
°
1
�
�
�
�
2
2
�'
�
�
�����
3
2
�
3
$
1
2
�'
3
��
�
:
3
s
�
�
�
3
1
2
��
2
°
3
�
�
�
1
3
��
�
�
2
3
��
�
s
2
3
�
6
�
�
3
';}
�
s
20 0
9.�8
�� o
� �o
,�.re a UA.
1 .
z�
3
�r
5
S
12� I
i
14
15
15
17
1�� 0
�0.3�
18
��
2#.
22
24
? 5 �'
�..
27
28
3�
31
33`
34
�� .
��
53 3
1� 93
1�0
331i
22 5
�.38
2?.5
7 78
?.5
2.18
55 0
15.48
g0
252
� 0
2.88
00
088
200
928
�0 �I
18 �8
�0 0
28 �8
d0 0
28.8�1
0 0
0 0�
t7 0 0.00 37
(see rgtire }
Ir7struction�
- a or eng
� 0.3a3 031 19t.19
�8
39
R-16 Fully insulated
�
��
illt7 p{ ���� �Ef7e5tr�tfOfP At�a at7d LEA
? � � � 24�_��1
Slab an Grade (see �rg�r-e ��
F-Factor X Length UA
�0 i
ilerttcai F2fre�tra�rofr Area I2lghted i! _ �lAl,�rea
0.35
�1
li3structiun�s -
Select R-Value
� PJo selection 0 ---
f�1 �
�2
'-
�3
�2
Overhead Glazing ��kylightsj
Lacs#ion of Deft#s
�*�
Component
11'Vidtl7 Heig�lt
�5
Instructions
Conditioned Space
duct Leakage Coefficient
6�4 I
Descri tion
`� `� � � Ir�r
Ref U-factor Qt Feet Feet '
r�.rea UA.
...
d6
FigLire 1.
A6�ove �-ade
1.00
Sum of UA
Envelope Heat Laad
SumvftlAX1T
Air Leakage Heat Lcad
VvrrrmeX O.6XS7X.048
Building Design Heat Lead
085.07
31,513 Btu !Hour
12,2�0 Btu ?Hour
43,789 Btu !Hour
6�
66
C7
��
��
TO
I]
8 0
Q.00
8 0
0.00
tJ0
000
tJ0
000
IJ 0
0.00
�.rr leakage + Er,4•e�voe Feat tOSS
��
��
Building and Duct Heat Load 43,78`3 Btu ?Hour
�2
tfrrr of Qtirerhead razing Area af�a' �}A tJ J 0.00
��
Orrets irr uncorrdrt�nned space' sum ofBur�drng t-feat toss X 4. P�
��
�wef�read �iazff�g Af12a 12f�'f7�EC� � - �}A/ArE7 �_� �
��,
��
dEqu'rpmen
��
� W �
Maxim�_umiHeat Ou�iput 54,�3f� Btu 1 Hour ',
8uildirrg arrd f�uct Feat toss X t.4D fnr Forged Arr Furr:aca
��
�
T�t�l ��1��5�f"��tOfii �f~�� �l;}t:{ �� �7�2rirrg 3.71:
57�
.�?fliR? .Of ��Oi' Sjlstem sizing ealcufatr'orrs� . ���7_�
Bu��drng and t3uct HeatLoss X f.25 for heat �rrmp
'-
- - 1
MECHANICAL SUBCONTRACTOR NOTE:
THE CALCULATIONS FOR HEATING SYSTEM SIZE ARE REQUIRED BY
THE WASHINGTON 2015 ENERGY CODE AND WAS COMPLETED AS
PART OF THE BUILDING PERMIT SUBMITTAL.
THE MECHANICAL SUBCONTRACTOR FOR THIS RESIDENCE SHALL
SIZE ALL HEATING EQUIPMENT PER WSEC AND SHALL COORDINATE
SIZING AND SELECTION OF EQUIPMENT WITH DEVELOPER /
BUILDER PRIOR TO PURCHASING OR INSTALLING THIS EQUIPMENT
2015 WA ENERGY CODE NOTES
POST ENERGY CODE COMPLIANCE CERTIFICATE
WITHIN 3' OF THE ELECTRICAL PANEL (105.4)
PROVIDE PROGRAMMABLE THERMOSTAT.
PROVIDE DUCT SEALING TESTS WHERE APPLICABLE.
PROVIDE DOOR BLOWER TEST AFFIDAVIT 9502.45)
WHEN APPLICABLE.
WHOLE HOUSE VENTILATION SYSTEM IS REQUIRED.
PROVIDE 100 CFM WHOLE HOUSE EXHAUST FAN TO
RUN INTERMITTENTLY ON TIMER.
HEATING SYSTEM
THIS RESIDENCE SHALL BE HEATED BY A HIGH EFFICIENCY
GAS FIRED FURNACE HEATING SYSTEM WITH FRESH AIR
INTAKE FOR WHOLE HOUSE VENTILATION AND FRESH AIR
INTAKE FOR COMBUSTION AIR.
ENERGY CODE CERTIFICATE
COMPLIANCE CERTIFICATE: PART OF THE WSEC. ALL NEW
RESIDENCES ARE REQUIRED TO POST THIS CERTIFICATE
WITHIN 3 FEET OF THE ELECTRICAL SUPPLY PANEL.
CERTIFICATE MUST BE COMPLETELY FILLED OUT AND
POSTED AT TIME OF FINAL INSPECTION. THIS
REQUIREMENT IS THE RESPONSIBILITY OF THE BUILDER.
2015 WASHINGTON ENERGY CODE
2015 WA ENERGY CODE REQUIREMENTS
THIS PROJECT WILL MEET THE 2015 WASHINGTON STATE ENERGY CODE BY
PROVIDING 3.5 ENERGY CREDITS.
ENERGY CREDIT OPTIONS 3A, 4, AND 5C (SHOWN BELOW) WILL BE IMPLEMENTED
TO MEET THE REQUIRED 3.5 ENERGY CREDITS
THE FURNACE AND WATER HEATER ARE TO OBTAIN COMBUSTION AIR AND
REMOVE EXHAUST GAS PER CODE REQUIRMENTS AND EQUIPMENT MANUFACTURER
REQUIREMENTS.
2015 WA ENERGY CODE BLOWER DOOR TESTING
A BLOWER DOOR TEST WILL NEED TO BE CONDUCTED BY THE CONTRACTOR AT
AREAS OF NEW CONSTRUCTION, PER W.S.E.C. R402.4.1.2. AIR LEAKAGE SHALL NOT
EXCEED 5 AIR CHANGES PER HOUR AND SHALL BE TESTED PER S.E.C. R402.4.1.2.
THE CONTRACTOR SHALL PROVIDE A WRITTEN REPORT OF THE TEST RESULTS,
SIGNED BY THE TESTING PARTY, TO THE BUILDING INSPECTOR, PRIOR TO
APPROVED FINAL INSPECTION.
2015 WA ENERGY COMPLIANCE OPTION
THE COMPLIANCE OPTION FOR THIS PROEJCT WILL BE "PRESCRIPTIVE".
2015 WA ENERGY CODE REQUIRED "R" & "U" VALUES
CLIMATE ZONE MARINE 4
REQUIRED PROPOSED
FENESTRATION U-FACTOR 0.30 0.28
SKYLIGHT U-FACTOR 0.50 0.49
(SKYLIGHTS ARE OVER AN UNHEATED PORCH -NOT PART OF ENERGY CODE CALC'S)
CEILING R-VALUE 49 R-49
WOOD FRAME WALL R-VALUE 21 R-21
FLOOR R-VALUE 30 R-30
FLOOR R-NACU E AT 11-7/8" TJ I'S 38 R-38
BELOW GRADE WALL R-VALUE R-21 R-21
SLAB R-VALUE &DEPTH R-10 (2" THICK) R-10
Prescripti�+e Energy Code Compliance for All Climate Zones in 1Nashington
rr,��ecc rr;ijrr,^�t;or, Cvratact Ir,fDrr7r2rrorr
E'�ans Residence Carl JColson -Architect PLLC
00�, 83rd Ace 4�r 23G23 �Oth AS�e 4"�r. Bothell '4h,fA 980�1
Edmonds, �!A 980�G 4�5-30�-3703 CarlCarlColson,�'trchitect.com
This project will use the requirements of the Prescriptive Path below and i€tcorparate the
the minimum values listed, In addition, based on the sire of the structure, tkte appropriate
number of additional credits are checked as chosen by tr3e permit applicant,
Authari=ad Regresantativa
Ail Climate Zones
R-1�ralue-
U-Factor
Fenestration U-Factar�
nla
0.?0
Skylight U-Factor
n1a
0.50
Gla_ed Fen?stratian SHGC���'
nla
Na
Ceiling'
49•
0.028
:";�aad Frame 1"lall��.,...
2�1 int
0.056
F,1ass'Nall R-Value'
2'I!2'I�'
0.058
Flaar
30�
0.029
Belo�a� Grady ��.:rall�....
'10!'15l2'I int + TE
0.042
Slab`' R=�v�alu? & D?�th
10. 2 fk
n.+a
*Ta;,le R402.'1.1 an�� Tavl? R�Q2.1.v F�sotnat?s il7cltl��?d an Peg? 2.
Data
Each dwelling unit in a residential building shall comply with sufficient options from Table R40B,2 so- as to
achieve the fallowing minimum number of credits;
i, Small Dwelling Unit; 9.5 credits
❑ D��n�•elling units less than '1500 square feet in conditioned Haar area �,t4�ith less thal7 ?00 square feet of
fenestration area..�dditians to existing cuilding that are greater than 500 square feet of heated Hoar
eras ut less than 1v00 square feet.
❑+� 2, Medium Dwelling Unit; 3,5 credits
x.11 d�a�elling units that are not includac' in �1 ar�3. E�cceptian; D�va�elling units serving R-2 occupancies
shall require 2.5 credits.
❑3, Large DwelllFyg Unit; 4.5ere�Fts
D�4a�elling units exceerfing 5000 square feet of canditianed Haar area.
❑4, Additions less than 500 square fee#: ,5 credi#s
Tal�le R4Q6.2 summary
GGtl1n D?SUrl�tlall
Gr�dItlS;�
1a
Efficien#EuildingEn�velape 1a
O.v
1 �
Efficient Buil�,ing En�velape 'I^
1.0
1c
EfFciant2uil�ingEn�valape 1c
2.0
1��
Efficient Euil,ing Envelop? 'Id
0.5
2a
.�,ir Leakage Control an�� Efficiant�ventilati��n 2a
O.0
2 ;
.sir Leakage Control and Efficient `�r�entilatian 2 :
1.0
2c
.�,ir Leakage Control and Efficient'�ientilatian 2c
1.v
3a
High Efficiency Hv.�C 3a
1.C�
3.�
Higl7 Efficiency Hl�`.�C `� ;
1.0
3c
High Efficiency H'J.�C 3c
1.5
?d
High Efficiency H'J.�C 3d
1.0
4
Hi jl7 Efficiency H`v�.�C Distri:,ution System
1.0
va
Efficient �.�rater Heating 5a
O.v
,=
Efficient��.'�at?rHeating5b
1.0
,=
Efficient�'A�aterHeatingvc
1.v
5 �
Efficient'.'�ater Heating vd
0.5
�3
Rene��,�,able Electric Energ�k
O.0
Total Credits
2015 WA ENERGY CODE, RESIDENTIAL PROVISIONS
ENERGY CREDITS
1.4
1.0
1.5
�.�
3.5E}
3a
HIGH EFFICIENCY HVAC' EC�L1IP11�IENT 3a:
Gas. propane or oil -fired ftu7iace with nuniuiuin AFLTE of 94°/n, or
Gas, propane or oiled -fired boiler with iuininiuin AFLTE of 92°/a
To qualify to claim this credit, the building permit drawings shall specify- the option
being selected and shall specify the heating equipment type and the nuninaum
e� ui �ment efficient .
1.0
4
HIGH EFFICIENCY HVAC L►ISTRIBliTION SY STEM:
1.0
All heating and cooling systeuj coinponents installed inside the conditioned space.
This includes all equipment and distribution system coinponents such as forced air
ducts, hydrouic piping, hydrouic floor heatuig loop, convectors and radiators. All
combustion equipment shall be direct vent or sealed cambiistion.
Far forced air ducts: A maxiiannn of 1 U linear feet of return ducts and 5 iiuear feet of
supply ducts maybe lacy#ed outside the conditioned space. All metallic ducts located
outside the conditioned space must have both transverse and longitudinal joints sealed
with mastic. If flex ducts are used, they cannot contain splices. Flex duct connections
must be made with nylon straps and installed using a plastic strapping tensioning tool.
Ducts located outside the canditianed space must be insulated to a minimum of R-8.
Locating system cou3poiients iii conditioned crawl spaces is not pei7uitted under this
option.
Electric resistance heat and ductless heat pumps are not perntted titrder this option.
Direct combustion heating equipment with AFUE less than 80°% is not permitted
under this ap#ion.
To qualify to claim this credit, the building periiiit drawings shall specify the option
being selected and shall specify the heating equipment type and shall show the
location of the heating and conlina equipment and all the duct�vnrk.
�c
EFFIC'IENT ��'ATER HEATING 7c:
1.5
Lvater heating system shall include one of the following:
Gas, propane or oil water heater with a nunimuin EF of 0.91
or
5alar water heating supplementing a minimum standard water heater. Solar water
heating will provide a rated nuniinuua savings of 85 tliernis ar 2000 kWh based on the
Solar Rating and Certification Corporation (SRCC') Annual Performance of ClG-300
Certified 5alar Water Heating Systems
OC
Electric heat pump water heater with a uvnimain EF of 2.0 and meeting the standards
of NEEA's Northern Climate Specifications far Heat Pump Wa#er Heaters
Ta qualify to claiur this credit, the building permit drawings shall specify the option
being selected and shall specify the water heater equipment type and the nunimniur
equipment efficiency and, for solar water heating systems, the calculation of the
minimum energy sati-iiigs.
RESUB
Jun 15 2020
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
Carl J. Colson -Architect
PLLC
23623 20th Ave. W
Bothell, WA 98021
425-806-3703
wwwCarlColsonArchitect. tom
Commercial &Residential
Architecture
Evans Residence
Project Address
20018 83rd Ave. W.,
Edmonds, WA 98026
New SFR at 20018 83rd Ave. W (Lot 1 of
PLN20180037)
City of Edmonds Permit #: SLD2020-0250
Project Client
Marne &Simon Evans
20020 83rd Ave. W.
Edmonds, WA 98026
Sheet Title
Washington State
Energy Code
Calculations
7543 REGISTERE
ARCHITECT
rim` '
CARL J. COLSON
S ATE OF WASHINGTO
ISSUED FOR PERMIT 1-21-2020
Document Set Type:
Revision Schedule
Rev.
# Date Description
1 16-15-20201Add Window/ Permit Revisions
DRAWING USE NOTIFICATION
This set of drawings is being issued as a Progress or Permit Set of Drawings
and is subject to change and adding of additional information and
drawings as required by review of the Building Department in the
jurisdiction where this project is located.
DO NOT USE THIS DRAWING FOR CONSTRUCTION UNLESS THIS
DRAWING HAS A BUILDING DEPARTMENT "APPROVED" STAMP
APPLIED BY THE BUILDING DEPARTMENT UPON COMPLETION OF
THE PERMIT REVIEW PROCESS.
Do not use this drawing for Bidding or Estimating Purposes unless
authorized by Client. During Construction Phase, the Clients General
Contractor (Builder) or Developer shall be responsible for ensuring that all
Construction Personnel of the General Contractor and all Subcontractors
are supplied with all Approved and most current documents.
ARCHITECTURAL COPYRIGHT
This sheet of drawings may not be reproduced in any form without prior
approval of Carl J. Colson -Architect PLLC.
These document, the ideas, and designs incorporated herein as an
instrument of service shall remain the property of Carl J. Colson -Architect
PLLC and are solely for the use on this project only. These files, drawings,
ideas, or designs may not be tramsmitted electronically without express
permission of Architect. They are not be used by the client or any other
party or entity on other projects, in whole or part, or as an extension to this
project except by agreement in writing with appropriate financial
compensation to Carl J. Colson -Architect PLLC.
Copyright Carl J. Colson -PLLC, 2019. All rights reserved.
Project Number
Sheet Issue Date �
04/29/13 �
Drawn By
Author Washington State Energy Code
Calculations
Scale
12" = 1'-0" Sheet Plot Dat�/14/2020 7:47:44 PM
www.CarlColsonArchitect.com �