Loading...
REVIEWED BLD2021-1445+Manufacturer_Specifications_and_Installation_Instructions+10.19.2021_2.28.17_PM+2471690RECEIVED Oct 20 2021 BONNCITY OF EDMONDS DEVELOPMENT999VIe€P, DEPART BCH0005MBACZA0000 - BLD2021-1445 SUBMITTAL Project Name: Project Location: Quote ID: Item #: 10001 REVIEW[ Submitted For: Submitted On: BY — EEA Submitted By., Submitted From: -4GFP� Identity #. Tag: ❑ For Record ❑ For Approval By: Date: Product Family: BCH Compressor Brand: Copeland Application: Outdoor Compressor Type: Scroll Temperature Range: Medium Temp Compressor Hp: 0.5 Voltage: (Volts/Ph/Hz) 208-23011160 Compressor Model. ZB06KAE-PFV Refrigerant Type: R404A Number of Compressor(s): 1 Piping: Standard Coil Type: Microchannel Note : This equipment meets the regulatory requirements for hydrofluorocarbons as of the manufacturing date. Only those refrigerants approved in the state for specific end uses may be used. D ONDS Ambient Temperature (°F) Saturated Suction Temperature (°F) Application Capacity* Altitude (BTU/H) (ft) AWEF Value 95 25.0 7,660 0 7.6 Compressor(s) Fan Motor(s) Electric Ratings RLA LRA Quantity Hp FLA Defrost High or Number of MCA MOPD Evap.Fan Defrost Type Low Amps? Contactors Amps Heater Amps 5.4 36 1 1115 0.5 AIR DEFROST 15 15 5 15 SpecificationsUnit Connects Receiver 90% Full Fan Blade(s) Approx. Sound Data Diameter Weigh Liquid Line Suction Standard Over Sized (in) (dB) 0.375 0.625 9 14 61 1670 AGENCY LISTINGS C Ug us 28 I/2 LIQUID AIR FLOW ♦ SUCTION 19 3/4 5 3/8 3 6 5/16 0011 3 3/16 2 3/4 r 24 318 CL 3/4 25 I/8 23 112 CL 2 3/16 UOM: inches Page 1 of 4 BCH0005MBACZA0000 - ONN SUBMITTAL Project Name: Project Location: Quote ID: Item A. 1000 Submitted For., Submitted On: Submitted By: Submitted From: Identity A, Tag: CABINET AND CONSTRUCTION MICROCHANNEL COIL TECHNOLOGY STANDARD ON ALL UNITS SERVICEABILITY • SUCTION SERVICE VALVES FOR HERMETIC AND SCROLL COMPRESSORS LOCATED OUTSIDE THE CABINET FOR QUICK INSTALLATIONS. • RECEIVER WITH FUSIBLE PLUG, LIQUID SHUTOFF VALVE AND CHARGING PORT IS STANDARD • LARGE ELECTRICAL PANEL FOR EASE OF ACCESS PREFABRICATED WIRING HARNESSES FOR TIGHT CRIMP CONNECTIONS AND CONSISTENT LABELING UNIT STAYS ON IF THE HOOD IS REMOVED FOR SERVICING SIGHT GLASS IS EASILY VIEWABLE Preferred Package Code - A0000 Motor - FIXED SPEED EC • Receiver Options - STANDARD Liquid Line Options - FILTER DRIER AND SIGHT GLASS • Discharge Line Options - HEAD PRESSURE VALVE 150# Fused Disconnect - NO FUSED DISCONNECT Crankcase Heater -CRANKCASE HEATER Pre Charged - NONE Hail Guard Factory Installed - NONE Walls or Obstructions for Horizontal Air Flow AIR W* FLOW MIN. QUALITY ALL UNITS ARE COMPLETELY LEAK TESTED IN A HELIUM ENVIRONMENT, BUMP TESTED AND ALLOWED TO CYCLE OFF ON THE HIGH AND LOW PRESSURE CONTROL. EACH UNIT HAS A COPY OF THE RUN DATA SHIPPED INSIDE THE ELECTRICAL PANEL ELECTRICAL CIRCUITS ARE COMPLETELY CHECKED FOR CONTINUITY PIPING IS LAID OUT TO MINIMIZE STRESS AND VIBRATION AND IS PRE -BENT TO ELIMINATE LEAKS ENCAPSULATED, AUTO -RESET, HIGH AND LOW PRESSURE CONTROLS TO ELIMINATE LEAKS (ADJUSTABLE LOW PRESSURE CONTROL STANDARD) PAINTED STEEL CABINETS FOR SUPERIOR STRENGTH AND CORROSION PROTECTION HEAVY DUTY, STEEL, 1-1/2" TALL BASE • Brand Label - BOHN Coil Selection - MICROCHANNEL COIL • Defrost Timer Options - NO TIMER Suction Line Options - SUCTION TUBE ONLY • Cabinet Selection - Painted Pressure Options - ADJUSTABLE LOW - FIXED HIGH Phase Loss Monitor - NONE Snow Legs - NONE Multiple Units with Horizontal Air Flow AIR FLOW AIR FLOW *W = W* unit width MIN. W* MIN. W* MIN. 4 � ' Capacities shown are Application Capacities reflecting nominal operation at 10°F TD. For models within the scope of the DOE AWEF (Annual Walk-in Energy Factor) standard, the Net Capacity is determined by the AHRI 1250 test method. DOE will publish this compliance data at www.regulations.doe.gov Page 2 of 4 BEL0060AS6AMAB0400 - OHN SUBMITTAL Project Name: Project Location: Quote ID., Item #: 2000 Submitted For., Submitted On: Submitted By., Submitted From: Identity #. Tag: ❑ For Record ❑ For Approval By: Date: Product Family. BEL Motor type 2 SPEED EC Defrost Type: Air Number of Fans: 1 Voltage: (Volts/Ph/Hz) 115/1/60 Fan HorsePower 1/20 Refrigerant Type: R404A Fins per Inch 6 Performance Data Capacity Air Flow Altitude AWEF Value TD SST Application Capacity" CFM Fan Diameter Air Throw (ft) ( ft ) Cooler > 32 Freezer <= 32 (°F) (°F) (BTU/H) (in.) Standard w/Collar 10 25.0 5,500 610 12 0 9 N/A Electrical Data or(s) Defrost Heater(s) Drain Pan Heater(s) Watts Amps Watts Amps Watts Amps 55 0.85 7/8" ELECTRICAL KNOCKOUTS 1 11/16 ° 3 1/8 3 1 3/8 � i-+4 5/I6 L REFRIGERANT ELECTRICAL 131/4 CONNECTION ENDI o CONNECTION END 6 I/8 6 I 17 1/4 -�-]w16 7/16 3/4" MPT (14 NPSI UOM: inches 29 1/2 DRAIN CONNECTION AGENCY LISTINGS V c &us 8 AIR FLOW :: 14 1 /16 17 I I I16 12 15 3/8 Page 3 of 4 BEL 0060AS6AMABO400 - ONN SUBMITTAL Project Name: Project Location: Quote ID: Item A. 2000 Submitted For., Submitted On: Submitted By: Submitted From: Identity A, Tag: EASE OF INSTALLATION SERVICE ALL ELECTRICAL COMPONENTS FACTORY WIRED TO TERMINAL BOARD AND IDENTIFIED, MAKING IT EASY TO FIELD WIRE THE UNIT RELIABLE DURABLE HEAVY GAUGE GRAINED ALUMINUM CABINET CLEANS EASILY AND LOOKS ATTRACTIVE MOLDED FAN GUARD AND ACCESS PANELS ARE MADE OF STRONG, DURABLE, AND NSF AND UL SANITATION RATED PLASTIC MATERIAL SWEAT CONNECTIONS TO REDUCE POTENTIAL FOR LEAKS Brand Label - BOHN • DTFD Option - None Fan Guard - Molded Drain Pan Type - Stucco Solenoid Voltage -115 • Coil Mechanical Option - Mounted Spodan TXV / Std Sol Mounted Customer Specified Valve Type - TXV f PLAN VIEW 11/2 H 2 y PLAN VIEW AIR FLOW 1 N One Evaporator NOTE: H =Total Height evaporator coil surface. PERFORMANCE EC MOTORS STANDARD ON ALL MODELS FOR IMPROVED UNIT EFFICIENCY VERSATILE LARGE DIAMETER DRAIN HOLE (314 " ID) IS LOCATED TOWARDS THE BACK OF THE UNIT MINIMAL HEIGHT OF THE LOW PROFILE SERIES MAKES IT IDEAL FOR LOW CEILING COOLERS CABINET DESIGN FEATURES HINGED, REMOVABLE FRONT ACCESS PANELS ON EACH SIDE FOR EASY ACCESS TO ELECTRICAL AND REFRIGERATION COMPONENTS LIQUID LINE SOLENOID WIRE HARNESS IS FACTORY -INSTALLED FOR QUICK INSTALLATION MOTORS PLUG INTO WIRING HARNESS FOR EASIER SERVICING • HINGED, REMOVABLE DRAIN PAN FOR EASY AND SAFE ACCESS PRE -DRILLED HOLES ON THE BACK OF THE UNIT FOR ROOM THERMOSTAT • QUICK REMOVAL FAN GUARD/MOTOR ASSEMBLY FOR EASY SERVICE OR REPLACEMENT OF AIR MOVER PARTS • INTERNAL PANELS ARE ISOLATED FOR QUIET OPERATION INTERNALLY ENHANCED TUBING AND FIN DESIGN FOR HIGHER EFFICIENCY Motor - 2 Speed EC Fan Blade - Standard Cabinet Type - Stucco • Controller Option - Mechanical Thermostat Fin Material - Aluminum • Liquid Temperature - 95 Valve Family - L t t 1 V2 H 1 V2 H y i 11/2H 3H 11/2H Two Evaporators " Capacities shown are Application Capacities reflecting nominal operation at 10°F TD. For models within the scope of the DOE AWEF (Annual Walk-in Energy Factor) standard, the Net Capacity is determined by the AHRI 1250 test method. DOE will publish this compliance data at www.regulations.doe.gov Page 4 of 4