REVIEWED BLD2021-1445+Manufacturer_Specifications_and_Installation_Instructions+10.19.2021_2.28.17_PM+2471690RECEIVED
Oct 20 2021
BONNCITY OF EDMONDS
DEVELOPMENT999VIe€P,
DEPART
BCH0005MBACZA0000 -
BLD2021-1445 SUBMITTAL
Project Name:
Project Location:
Quote ID:
Item #:
10001
REVIEW[
Submitted For:
Submitted On:
BY —
EEA
Submitted By.,
Submitted From:
-4GFP�
Identity #.
Tag:
❑ For Record ❑ For Approval By:
Date:
Product Family:
BCH
Compressor Brand:
Copeland
Application:
Outdoor
Compressor Type:
Scroll
Temperature Range:
Medium Temp
Compressor Hp:
0.5
Voltage: (Volts/Ph/Hz)
208-23011160
Compressor Model.
ZB06KAE-PFV
Refrigerant Type:
R404A
Number of Compressor(s):
1
Piping:
Standard
Coil Type:
Microchannel
Note : This equipment meets the regulatory requirements for hydrofluorocarbons as of the manufacturing date. Only those refrigerants approved in the state for specific end uses may be used.
D
ONDS
Ambient
Temperature (°F)
Saturated Suction
Temperature (°F)
Application Capacity* Altitude
(BTU/H) (ft)
AWEF Value
95
25.0
7,660 0
7.6
Compressor(s)
Fan Motor(s)
Electric Ratings
RLA LRA
Quantity Hp FLA Defrost
High or
Number of MCA
MOPD
Evap.Fan Defrost
Type
Low Amps?
Contactors
Amps Heater
Amps
5.4
36
1
1115
0.5 AIR DEFROST
15
15
5 15
SpecificationsUnit
Connects
Receiver 90% Full
Fan Blade(s)
Approx.
Sound Data
Diameter
Weigh
Liquid Line
Suction Standard Over Sized
(in)
(dB)
0.375
0.625 9
14
61
1670
AGENCY LISTINGS
C Ug us
28 I/2
LIQUID
AIR FLOW ♦ SUCTION 19 3/4 5 3/8
3
6 5/16 0011
3 3/16 2 3/4
r 24 318 CL
3/4 25 I/8
23 112 CL
2 3/16
UOM: inches
Page 1 of 4
BCH0005MBACZA0000 -
ONN
SUBMITTAL
Project Name:
Project Location:
Quote ID:
Item A.
1000
Submitted For.,
Submitted On:
Submitted By:
Submitted From:
Identity A,
Tag:
CABINET AND CONSTRUCTION
MICROCHANNEL COIL TECHNOLOGY STANDARD ON ALL UNITS
SERVICEABILITY
• SUCTION SERVICE VALVES FOR HERMETIC AND SCROLL COMPRESSORS
LOCATED OUTSIDE THE CABINET FOR QUICK INSTALLATIONS.
• RECEIVER WITH FUSIBLE PLUG, LIQUID SHUTOFF VALVE AND CHARGING PORT
IS STANDARD
• LARGE ELECTRICAL PANEL FOR EASE OF ACCESS
PREFABRICATED WIRING HARNESSES FOR TIGHT CRIMP CONNECTIONS AND
CONSISTENT LABELING
UNIT STAYS ON IF THE HOOD IS REMOVED FOR SERVICING
SIGHT GLASS IS EASILY VIEWABLE
Preferred Package Code - A0000
Motor - FIXED SPEED EC
• Receiver Options - STANDARD
Liquid Line Options - FILTER DRIER AND SIGHT GLASS
• Discharge Line Options - HEAD PRESSURE VALVE 150#
Fused Disconnect - NO FUSED DISCONNECT
Crankcase Heater -CRANKCASE HEATER
Pre Charged - NONE
Hail Guard Factory Installed - NONE
Walls or Obstructions for
Horizontal Air Flow
AIR W*
FLOW MIN.
QUALITY
ALL UNITS ARE COMPLETELY LEAK TESTED IN A HELIUM ENVIRONMENT, BUMP
TESTED AND ALLOWED TO CYCLE OFF ON THE HIGH AND LOW PRESSURE
CONTROL. EACH UNIT HAS A COPY OF THE RUN DATA SHIPPED INSIDE THE
ELECTRICAL PANEL
ELECTRICAL CIRCUITS ARE COMPLETELY CHECKED FOR CONTINUITY
PIPING IS LAID OUT TO MINIMIZE STRESS AND VIBRATION AND IS PRE -BENT TO
ELIMINATE LEAKS
ENCAPSULATED, AUTO -RESET, HIGH AND LOW PRESSURE CONTROLS TO
ELIMINATE LEAKS (ADJUSTABLE LOW PRESSURE CONTROL STANDARD)
PAINTED STEEL CABINETS FOR SUPERIOR STRENGTH AND CORROSION
PROTECTION
HEAVY DUTY, STEEL, 1-1/2" TALL BASE
• Brand Label - BOHN
Coil Selection - MICROCHANNEL COIL
• Defrost Timer Options - NO TIMER
Suction Line Options - SUCTION TUBE ONLY
• Cabinet Selection - Painted
Pressure Options - ADJUSTABLE LOW - FIXED HIGH
Phase Loss Monitor - NONE
Snow Legs - NONE
Multiple Units with Horizontal Air Flow
AIR FLOW AIR FLOW
*W = W*
unit width MIN.
W* MIN. W* MIN.
4 �
' Capacities shown are Application Capacities reflecting nominal operation at 10°F TD. For models within the scope of the DOE AWEF (Annual Walk-in Energy Factor) standard, the Net Capacity
is determined by the AHRI 1250 test method. DOE will publish this compliance data at www.regulations.doe.gov
Page 2 of 4
BEL0060AS6AMAB0400 -
OHN
SUBMITTAL
Project Name:
Project Location:
Quote ID.,
Item #:
2000
Submitted For.,
Submitted On:
Submitted By.,
Submitted From:
Identity #.
Tag:
❑ For Record ❑ For Approval By:
Date:
Product Family.
BEL
Motor type
2 SPEED EC
Defrost Type:
Air
Number of Fans:
1
Voltage: (Volts/Ph/Hz)
115/1/60
Fan HorsePower
1/20
Refrigerant Type:
R404A
Fins per Inch
6
Performance Data
Capacity
Air Flow
Altitude
AWEF Value
TD SST
Application Capacity"
CFM Fan Diameter Air Throw (ft) ( ft )
Cooler > 32
Freezer <= 32
(°F) (°F)
(BTU/H)
(in.) Standard w/Collar
10 25.0
5,500
610
12
0
9
N/A
Electrical Data
or(s) Defrost Heater(s)
Drain Pan Heater(s)
Watts
Amps Watts Amps
Watts
Amps
55
0.85
7/8" ELECTRICAL
KNOCKOUTS
1 11/16
° 3 1/8
3 1 3/8
� i-+4 5/I6
L
REFRIGERANT ELECTRICAL 131/4
CONNECTION ENDI o CONNECTION END
6 I/8 6 I
17 1/4
-�-]w16 7/16
3/4" MPT (14 NPSI
UOM: inches 29 1/2 DRAIN CONNECTION
AGENCY LISTINGS
V c &us 8
AIR FLOW :: 14 1 /16 17 I I I16
12
15 3/8
Page 3 of 4
BEL 0060AS6AMABO400 -
ONN
SUBMITTAL
Project Name:
Project Location:
Quote ID:
Item A.
2000
Submitted For.,
Submitted On:
Submitted By:
Submitted From:
Identity A,
Tag:
EASE OF INSTALLATION SERVICE
ALL ELECTRICAL COMPONENTS FACTORY WIRED TO TERMINAL BOARD AND
IDENTIFIED, MAKING IT EASY TO FIELD WIRE THE UNIT
RELIABLE DURABLE
HEAVY GAUGE GRAINED ALUMINUM CABINET CLEANS EASILY AND LOOKS
ATTRACTIVE
MOLDED FAN GUARD AND ACCESS PANELS ARE MADE OF STRONG, DURABLE,
AND NSF AND UL SANITATION RATED PLASTIC MATERIAL
SWEAT CONNECTIONS TO REDUCE POTENTIAL FOR LEAKS
Brand Label - BOHN
• DTFD Option - None
Fan Guard - Molded
Drain Pan Type - Stucco
Solenoid Voltage -115
• Coil Mechanical Option - Mounted Spodan TXV / Std Sol Mounted
Customer Specified Valve Type - TXV
f PLAN VIEW
11/2 H
2 y
PLAN VIEW AIR FLOW
1 N
One Evaporator
NOTE:
H =Total Height
evaporator
coil surface.
PERFORMANCE
EC MOTORS STANDARD ON ALL MODELS FOR IMPROVED UNIT EFFICIENCY
VERSATILE
LARGE DIAMETER DRAIN HOLE (314 " ID) IS LOCATED TOWARDS THE BACK OF
THE UNIT
MINIMAL HEIGHT OF THE LOW PROFILE SERIES MAKES IT IDEAL FOR LOW
CEILING COOLERS
CABINET DESIGN FEATURES HINGED, REMOVABLE FRONT ACCESS PANELS ON
EACH SIDE FOR EASY ACCESS TO ELECTRICAL AND REFRIGERATION
COMPONENTS
LIQUID LINE SOLENOID WIRE HARNESS IS FACTORY -INSTALLED FOR QUICK
INSTALLATION
MOTORS PLUG INTO WIRING HARNESS FOR EASIER SERVICING
• HINGED, REMOVABLE DRAIN PAN FOR EASY AND SAFE ACCESS
PRE -DRILLED HOLES ON THE BACK OF THE UNIT FOR ROOM THERMOSTAT
• QUICK REMOVAL FAN GUARD/MOTOR ASSEMBLY FOR EASY SERVICE OR
REPLACEMENT OF AIR MOVER PARTS
• INTERNAL PANELS ARE ISOLATED FOR QUIET OPERATION
INTERNALLY ENHANCED TUBING AND FIN DESIGN FOR HIGHER EFFICIENCY
Motor - 2 Speed EC
Fan Blade - Standard
Cabinet Type - Stucco
• Controller Option - Mechanical Thermostat
Fin Material - Aluminum
• Liquid Temperature - 95
Valve Family - L
t t
1 V2 H 1 V2 H
y i
11/2H 3H 11/2H
Two Evaporators
" Capacities shown are Application Capacities reflecting nominal operation at 10°F TD. For models within the scope of the DOE AWEF (Annual Walk-in Energy Factor) standard, the Net Capacity
is determined by the AHRI 1250 test method. DOE will publish this compliance data at www.regulations.doe.gov