Loading...
APPROVED STM BLD2021-0288+Storm_Drainage_Report+2.23.2021_3.29.42_PM+2060649RAM Engineering To: City of Edmonds Engineering Division From: Rob Long, PE RAM Engineering Subject: Select- 8805 220th St SW Short Plat- Lot 3 Stormwater Memo RAM Job No. 19-026 RECEIVED Mar 12 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPHRTMENT Memorandum Date: February 16, 2021 APPLIES WITH APPLICABLE CITY STORMWATER CODE This memo provides a summary of the stormwater hard surface allocation for Lot 3 of the Select- 8805 220th St SW Short Plat (PLN 2020-0009). A site -specific geotechnical evaluation only recommends two possible stormwater BMPs for the site; perforated stub -out connection and BMP T5.13: Post -Construction Soil Quality and Depth. Project impervious/hard surface (roof, driveway, walk/patio areas) will be managed by a shared stormwater detention tank system with the short plat development. The shared detention tank system has been designed as part of the short plat development and thus includes hard surface areas allocated for each individual lot (see Select 220t" St SW Short Plat Stormwater Site Plan Report). Lot 3 has an allocation of 4,161 sf of impervious/hard surface, which include roof, driveway, and patio/walkway areas. Below is a stormwater control summary table for Lot 3: Lot 3 Stormwater Control Summary: Project Site Category: Category 2 (part of the Select- 8805 220th St SW Short Plat) Discharge Location: City's Municipal Separate Storm Sewer System (MS4) Type of Area Square Footage Stormwater Facility Lawn and Landscape 5,148 sf Soil Amendments (BMP T5.13) Roofs 2,661 sf Detention Tank Hard Surfaces 1,500 sf Detention Tank 25% Retrofit 0 SF None 2116/ZOZ 1 Select- 8805 220th St SW Short Plat- Lot 3 Stormwater Memo RAM lob No. 19-026 Page 2 of 2 Select 8805 220t" St SW Short Plat Lot 3 Hard Surface Summary: Roof = 2,661 sf Driveway = 100 sf Patio/Walk = 1,400 sf Total = 4,161 sf I } CONNECTION PER p7i STD DWG Na SD-639 - (SEE DETAR ON SHTI GN-01) IE 4.i.I Dt 00201500 I a fE 43.E 0.* n 1 � I I T� SEH" STUB fE 43U 1f SHORT PLAT IMPROVEMENTS 1 CQV5TRUCIE9 .AS• PART OF - 7HE 2207H Sr SW swafrr PLAr (PLN2n2n00b9} 30' DRAINAGE & JDINT U77UTY EASEMENT (TY?} j I I 20' PRIVA iE ACM -SS �asNr I 4" PVC FOOIWr DRAIN 0 1.OR MIN I 1 ' MIN LENGI DRAIN DR QEOTEC 9'3124'W 1-.L7 ..:. ..-(PER In h RECOMMENOA. ! __ Epq js 7 r r ddr r �s 1•,': (PLAN 3110 C,L' } PROPOSED HOUSE t I I FF 436. 70CAMAGE .I I FT- 436.45 9.309 SF ¢ n SDCO 8,189 SF (NET) IE 434.01 oo 4 II i I CoVfl?E} 1$ Parch i I 1 X44M.6f 2.561 SF. �5 ' . I_ -- 4" V7 ® -- '•` I. r 2.OX MIN N8928'11-W 132.86- N I . I — — — _ _ — I WATER VI r INSTA AS`� — — — — PART ClF SHORT PLA T. I ` INSTALL 1' WATER ME7ER AND I , �. Yj 1-112- PE 060 PSI) SERWCE LINE . j FROM WATER METER TO HDLISE II � / � (RACER WRE 70 8E INSTALLED 1 Q j .: VAIM WATER LINE) 1�y Ir I I RAM Engineering 165311311 Ave W, Suite A108 Lynnwood WA 98037 (425)678-6960 RAMengineeringinc.com