Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
REVIEWED BLD BLD2020-1195+Manufacturer_Specifications_and_Installation_Instructions+11.5.2020_11.39.02_AM
Job Name: System Reference: Date: GENERAL FEATURES • Variable speed INVERTER -driven compressor • Energy Star° certified' (non -ducted) • M-NET connection through outdoor unit • Quiet outdoor unit operation as low as 50 dB(A) • New Intelligent Power Module (IPM) for reduced power loss • Selectable thermal lockout/restart function • Optional base pan heater • High pressure switch for additional protection • Thermal differential of +/-1 ° F from setpoint 'ENERGY STAR products are third -party certified by an EPA -recognized Certification Body. Specifications are subject to change without notice. © 2018 Mitsubishi Electric US, Inc. Outdoor Model number Indoor • ' Maximum Capacity Btu/h Rated Capacity Btu/h Minimum Capacity Btu/h Cooling*1 Maximum Power Input W Rated Power Input W Power Factor % l !Ducted Ducted 20,000 18,000 19,000 20,000 5,700 2,245 1,417 1,709 2,000 98.7 99.3 99.9 Heating at 47° F*2 Maximum Capacity Btu/h 25,000 Rated Capacity Btu/h 22,000 Minimum Capacity Btu/h 7,400 Maximum Power Input W 2,455 Rated Power Input W 1,641 1,706 1,771 Power Factor % 96.2 97.9 99.6 Heating at 17° F *3 Maximum Capacity Btu/h 15,500 15,000 14,500 Rated Capacity Btu/h 12,500 13,000 13,500 Maximum Power Input W 1,750 1,780 1,810 Rated Power Input W 1,300 1,325 1,350 Heating at 5° F *4 Maximum Capacity Btu/h 11,100 11,000 10,900 ' Maximum Power Input - W 1,600 1,625 1,650 Efficiency SEER 20.00 18.00 16.00 EER *1 12.70 11.35 10.00 HSPF (IV) --------- ---- 10.00 9.65 9.30 COP at 47° F *2 3.93 3.78 3.64 COP at 17° F *3 2.82 2.87 2.93 ENERGY STAR® Certified YES NO NO Electrical Voltage, Phase, Frequency 208 / 230V, 1-phase, 60 Hz Guaranteed Voltage Range V AC 187 - 253 Voltage: Indoor - Outdoor, S1-S2 V AC 208V / 230 Voltage: Indoor - Outdoor, S2-S3 V DC 12-24 Voltage: Indoor - Remote controller V DC 24 Recommended Fuse/Breaker Size A 20 1 Specifications are subject to change without notice. © 2018 Mitsubishi Electric US, Inc. Modele' indoor unit type • 'e Ducted Recommended Wire Size AWG AWG14 (Indoor - Outdoor) Outdoor unit MCA A 17.2 Fan Motor Full Load Amperage A 1.77 Fan Motor Output W 64 Airflow Rate CFM 1,342 / 1,458 Refrigerant Control Liner Expansion Valve Defrost Method Reverse Cycle Heat Exchanger Type Plate fin coil Sound Pressure Level, Cooling*1 dB(A) 50 Sound Pressure Level, Heating*2 dB(A) 54 Compressor Type Twin Rotary type Compressor Model SNB140FQUH2T Compressor Motor Output kW 1.5 Compressor Rated Load Amps A 10.7 Compressor Locked Rotor Amps A 15.5 Compressor Oil Type // Charge oz. NE022 / 20.3 External Finish Color Munsell 3.0Y 7.811.1 Base Pan Heater Optional Unit Dimensions W: In. [mm] 33-1/16 [840] D: In. [mm] 13 [330] H: In. [mm] 27-15/16 [710] Package Dimensions W: In. [mm] 40 [1,010] D: In. [mm] 18-1/2 [470] H: In. [mm] 33-1/2 [850] Unit Weight Lbs. [kg] 126 [57] Package Weight Lbs. [kg] 147 [67] Outdoor unit operating temperature range Cooling Intake Air Temp (Maximum / Minimum) OF 14 to 115 Heating Intake Air Temp (Maximum / Minimum) OF 5 to 75 Thermal Lock -out / Re -start Temperatures OF Cooling: 10.4 / 14 Heating: 1.5 / 5 Specifications are subject to change without notice. © 2018 Mitsubishi Electric US, Inc. OMMI Outdoor unit MXZ-2C2M , Modelnumber Indoor t r Ducted Ducted R410A Refrigerant Type T- Charge Lbs., Oz. 3,15 Maximum Number of Connected IDU 2 Indoor unit connection Minimum Number of Connected IDU 2 Maximum connected capacity Btu/h 24,000 Minimum connected capacity Btu/h 12,000 Gas Pipe Size O.D. (Flared) In. [mm] 3/8 [9.52] Liquid Pipe Size O.D. (Flared) In. [mm] 1/4 [6.35] Total Piping Length Ft. [m] 164 [50] Maximum Height Difference, ODU above IDU Ft. [m] 33 [10] Piping Maximum Height Difference, ODU below IDU Ft. [m] 49 [15] Farthest Piping Length from ODU to IDU Ft. [m] 82 (25] Maximum Number of Bends 50 AHRI Rated *1 Cooling (Indoor // Outdoor) OF 80°F DB, 67°F WB // 95°F DB, 75°F WB Conditions (Rated data is determined *2 Heating at 47°F (Indoor // Outdoor) °F 70°F DB, 60°F WB // 47-F DB, 43°F WB at a fixed compressor speed) *3 Heating at 17°F (Indoor // Outdoor) OF 70°F DB, 60°F WB // 17°F DB, 15°F WB Conditions *4 Heating at 5°F (Indoor // Outdoor) OF 70°F DB, 60°F WB // -4°F DB, -5°F WB For reference to connected capacity charts, please refer MXZ-2C20NA2-U1 Operational Performance. Notes: Specifications are subject to change without notice. © 2018 Mitsubishi Electric US, Inc. Port Adapter size: 3/8" x 5/8" ❑ PAC-SG76RJ-E Port Adapter size: 1/4" x 3/8" ❑ PAC-493PI Joint Pipe Port Adapter size: 3/8" X 1/2" ❑ MAC-A454JP-E Port Adapter size: 1/2" X 3/8" ❑ MAC-A455JP-E Port Adapter size: 1/2" X 5/8" ❑ MAC-A456JP-E Air Discharge Guide ❑ MAC-856SG Base Pan Heater ❑ PAC-646BH-E Control Cable ❑ CW162S 3-pole Disconnect ❑ TAZ-MS303 M-NET Adapter ❑ PAC-IF01 MNT E Wall Mounting Bracket (Powder -coated Steel) ❑ QSWB2000M-1 Wall Mounting Bracket (316 Series Stainless Steel) ❑ QSWBSS Outdoor Unit Mounting Pad 24" x 42" x 3" ❑ ULTRILITE2 MiniSplit Mounting Stand -Dual Fan models - 12" ❑ QSMS1202M MiniSplit Mounting Stand -Dual Fan models - 18" ❑ QSMS1802M MiniSplit Mounting Stand -Dual Fan models - 24" ❑ QSMS2402M 1/4 x 1/2 x 15' / 1/2" Lineset (Twin -Tube Insulation) ❑ MLS141212T-15 1/4 x 1/2 x 30' / 1/2" Lineset (Twin -Tube Insulation) ❑ MLS141212T-30 1/4 x 112 x 50' / 1/2" Lineset (Twin -Tube Insulation) ❑ MLS141212T-50 1/4 x 1/2 x 65' / 1/2" Lineset (Twin -Tube Insulation) ❑ MLS141212T-65 ❑ MLS141212T-100 1/4 x 1/2 x 100' / 1/2" Lineset (Twin -Tube Insulation) Diamondback Linesets 3/8 x 5/8 x 10' 1 1/2" Lineset (Twin -Tube Insulation) ❑ MPLS385812T-10 3/8 x 5/8 x 15' / 1/2" Lineset (Twin -Tube Insulation) ❑ MPLS385812T-15 3/8 x 5/8 x 30' / 1/2" Lineset (Twin -Tube Insulation) ❑ MPLS385812T 30 3/8 x 5/8 x 50' / 1/2" Lineset (Twin -Tube Insulation) ❑ MPLS385812T-50 3/8 x 5/8 x 65' / 1/2" Lineset (Twin -Tube Insulation) ❑ MPLS385812T-65 3/8 x 5/8 x 100' / 1/2" Lineset (Twin -Tube Insulation) ❑ MPLS385812T-100 Linesets are indoor unit specific and will be listed in the IDU information - the Joint Pipe adaptors are used in this application Specifications are subject to change without notice. © 2018 Mitsubishi Electric US, Inc. 1.FREE SPACE E E E 3-15/16' or more e 0 6 3-15/76' ar more 13-25/32' ar more 2-SERVICE SPACE e E 3-15/16' or more o- SERVICE SPACE 13-25/32' or more 13-25/32' or more FORM# MXZ-2C20NA2 - 201805 Unit: inch (mm) MITSUBISHI ELECTRIC COOLING & HEATING 1340 Satellite Boulevard, Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com ET- us Intertek Specifications are subject to change without notice. © 2018 Mitsubishi Electric US, Inc. Job Name: System Reference: Date: ` Indoor Unit: Wireless Remote Controller MSZ-GL09NA I GENERAL FEATURES • Slim wall -mounted indoor units provide zone comfort control • The outdoor unit powers the indoor unit, and should a power outage occur, the system is automatically restarted when power returns • Multiple fan speed options: Quiet, Low, Medium, High, Super -high, Auto • Multiple control options available: Hand-held Remote Controller (provided with unit) kumo cloud® smart device app for remote access Third -party interface options - Wired or wireless controllers • Hot -Start Technology: no cold air rush at equipment startup or when restarting after Defrost Cycle • Quiet operation • Smart Set: recalls a preferred preset temperature setting at the touch of a button Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Cooling Capacity, 3 Btu/h 9,000 Heating Capacity2, 3 Btu/h 10,900 Voltage, Phase, Frequency 208/230V, 1 phase, 60Hz Guaranteed Voltage Range V AC 187 - 253 Electrical Voltage: Indoor - Outdoor, S1-S2 VAC 2081230 Voltage: Indoor - Outdoor, S2-S3 V DC 24 Voltage: Indoor - Remote Controller Wireless Type MCA A 1 Blower Motor Full Load Amperage A 0.76 Blower Motor Output W 30 Airflow Rate at Cooling, Dry CFM 399-321-237-170-145 Airflow Rate at Cooling, Wet CFM 364-286-201-134-109 Airflow Rate at Heating, Dry CFM 406-321-237-170-145 Sound Pressure Level (Cooling) dB(A) 43-37-30-22-19 Sound Pressure Level (Heating) dB(A) 43-37-30-22-19 Drain Pipe Size In. (mm) 5/8 (15.88) Heat Exchanger Type Plate fin coil External Finish Color Munsell 1.0Y 9.210.2 Unit Dimensions W: In. (mm) 31-7116 (798) D: In. (mm) 9-1/8 (232) H: In. (mm) 11-5/8 (295) Package Dimensions W: In. (mm) 33-1/2 (850) D: In. (mm) 12 (300) H: In. (mm) 14 (350) Unit Weight Lbs. (kg) 22 (10) Package Weight Lbs. (kg) 26 (11.5) Refrigerant Type R410A Piping Gas Pipe Size O.D. (Flared) In. (mm) 3/8 (9.52) Liquid Pipe Size O.D. (Flared) in. (mm) 1/4 (6.35) Notes: Nominal Conditions 'Cooling (Indoor // Outdoor) I T ( 80 DB, 67 WB // 95 DB, 75 WB I 2Heating at 47°F (Indoor // Outdoor) T 70 DB, 60 WB // 47 DB, 43 WB 3Capacity varies based on the number of indoor units operating and the model of the Multi -zone Outdoor Unit. For reference to connected capacity charts, please refer Multi -zone Outdoor Unit Operational Performance. Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Anti -allergy Enzyme Filter ❑ MAC-408FT E Backlit, Wall -mounted, Wireless Controller ❑ MHK1 Portable Central Controller ❑ MCCH1 Wired MA Controller' ❑ PAR-33MAA Simple MA Controller) ❑ PAC-YT53GRAU Touch MA Controller) ❑ PAR-CT01 MAU-SB Wired Remote Sensor ❑ M21-EAA-307 Wireless Temperature and Humidity Sensor ❑ PAC-USWHS003-TH-1 Outside Air Sensor for MHK1 ❑ MOS1 System Control Interface2 ❑ MAC-3331F-E Wireless Interface ❑ PAC-USWHS002-WF-1 Thermostat Interface ❑ PAC-US444CN-1 kumo station® ❑ PAC-WHS01 HC-E USNAP Interface ❑ PAC-WHS01UP-E IT Extender ❑ PAC-WHS011E-E BACnet® and MODBUS® Interface ❑ PAC-UKPRC001-CN-1 Lockdown Bracket for Hand-held Remote Controllers ❑ RCMKP1 CB Blue Diamond Sensor Extension Cable —15 Ft. ❑ C13-103 Blue Diamond Alarm Extension Cable —6.5 Ft. ❑ C13-192 Blue Diamond MultiTank— collection tank for use with multiple pumps ❑ C21-014 Blue Diamond Rubber Foot Pads ❑ F10-010 Mini Condensate Pump —230 volt application ❑ S130-230 MegaBlue Advanced Blue Diamond Condensate Pump w/ Reservoir & Sensor ❑ X87-835 - 110 to 250V MaxiBlue Advanced Blue Diamond Mini Condensate Pump w/ Reservoir & Sensor (110V) up to 48,000 Btu/h [recommended] ❑ X87-711 - 110V Advanced Blue Diamond Mini Condensate Pump w/ Reservoir & Sensor (2081230V) [recommended] ❑ X87-721 - 208/230V MicroBlue Blue Diamond Mini Condensate Pump (110/208/230V) up to 18,000 Btu/h ❑ X85-003 Fascia Kit for MicroBlue Pump — mounts the MicroBlue and sensor directly beneath the indoor unit ❑ T18-016 Drain Pan Level Sensor ❑ DPLS2 (30A/600V/UL) [fits 2" X 4" utility box] - Black ❑ TAZ-MS303 (30A/600V/UL) [fits 2" X 4" utility box] - White ❑ TAZ-MS303W • KegUireS MAG-3331r-t 2 Allows indoor units to connect to an MA Controller Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. 9-Il8 3/16 Indoor u L LJ M M h 1-3/4 1-15/16_I 24-3/85 I/8� 2 5/1i 3/4 M 2-3/16 I ISl16 1-3/16 FORM# MSZ-GL09NA FOR MXZ-C MULTI -ZONE HEAT PUMP SYSTEMS - 201902 Unit: inch Air in Insulation of - 318 O.D a Liquid line o1/4 19 - 11/16 (Flared connection o1/4) FL Gas line o3/8 16 - 15/16 (Flared connection: o3/8 (GLO6/09112NA), o112 (GL15NA)) Drain hose Insulation of-1/8 0.1) connected part o5/8 O.D MtMITSUBISHI ELECTRIC COOLING & HEATING 1340 Satellite Boulevard, Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Job Name: System Reference: Date: Indoor Unit: MSZ-GL06NA Wireless Remote Controller �a GENERAL FEATURES • Slim wall -mounted indoor units provide zone comfort control • The outdoor unit powers the indoor unit, and should a power outage occur, the system is automatically restarted when power returns • Multiple fan speed options: Quiet, Low, Medium, High, Super -high, Auto • Multiple control options available: Hand-held Remote Controller (provided with unit) - kumo cloud® smart device app for remote access - Third -party interface options - Wired or wireless controllers • Hot -Start Technology: no cold air rush at equipment startup or when restarting after Defrost Cycle • Quiet operation • Smart Set: recalls a preferred preset temperature setting at the touch of a button Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Cooling Capacity', 3 Btu/h 6,000 Heating Capacity2, 3 Btu/h 7,200 Voltage, Phase, Frequency 208/230V, 1 phase, 60Hz Guaranteed Voltage Range VAC 187 - 253 Electrical Voltage: Indoor - Outdoor, S1-S2 V AC 208 / 230 Voltage: Indoor - Outdoor, S2-S3 V DC 24 Voltage: Indoor - Remote Controller Wireless Type MCA A 1 Blower Motor Full Load Amperage A 0.76 Blower Motor Output W 30 Airflow Rate at Cooling, Dry CFM 145-170-237-321-399 Airflow Rate at Cooling, Wet CFM 109-134-201-286-364 Airflow Rate at Heating, Dry CFM 145-170-237-321-406 Sound Pressure Level (Cooling) dB(A) 19-22-30-37-43 Sound Pressure Level (Heating) dB(A) 19-22-30-37-43 Drain Pipe Size In. (mm) 5/8 (15.88) Heat Exchanger Type Plate fin coil External Finish Color Munsell 1.0Y 9.210.2 Unit Dimensions In. (mm) 31-7116 (798) : In. (mm) 9-1/8 (232) In. (mm) 11-5/8 (295) Package Dimensions - - - - : In. (mm) 33-1/2 (850) : In. (mm) 12 (300) r—I 1: In. (mm) 14 (350) Unit Weight Lbs. (kg) 22 (10) Package Weight Lbs. (kg) 26 (11.5) Refrigerant Type R410A Piping Gas Pipe Size O.D. (Flared) In. (mm) 3/8 (9.52) Liquid Pipe Size O.D. (Flared) In. (mm) 1/4 (6.35) Notes: Nominal Conditions tCooling (Indoor H Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB 21-leating at 47T (indoor // Outdoor) °F 70 DB, 60 WB H 47 DB, 43 WB 3Capacity varies based on the number of indoor units operating and the model of the Multi -zone Outdoor Unit. For reference to connected capacity charts, please refer Multi -zone Outdoor Unit Operational Performance. Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Anti -allergy Enzyme Filter ❑ MAC-408FT E Backlit, Wall -mounted, Wireless Controller ❑ MHK1 Portable Central Controller ❑ MCCH1 Wired MA Controller) ❑ PAR-33MAA Simple MA Controller) ❑ PAC-YT53CRAU Touch MA ControllerT ❑ PAR-CT01MAU-SB Wired Remote Sensor ❑ M21-EAA-307 Wireless Temperature and Humidity Sensor ❑ PAC-USWHS003-TH-1 Outside Air Sensor for MHK1 ❑ MOS1 System Control Interface2 ❑ MAC-3331F-E Wireless Interface ❑ PAC-USWHS002-WF-1 Thermostat Interface ❑ PAC-US444CN-1 kumo station® ❑ PAC-WHS01 HC-E USNAP Interface ❑ PAC-WHS01UP-E IT Extender ❑ PAC-WHS011E-E BACnet® and MODBUS® Interface ❑ PAC-UKPRC001-CN-1 Lockdown Bracket for Hand-held Remote Controllers ❑ RCMKP1 CB Blue Diamond Sensor Extension Cable —15 Ft. ❑ C13-103 Blue Diamond Alarm Extension Cable —6.5 Ft. ❑ C13-192 Blue Diamond MultiTank—collection tank for use with multiple pumps ❑ C21-014 Blue Diamond Rubber Foot Pads ❑ F10-010 Mini Condensate Pump —230 volt application ❑ S130-230 MegaBlue Advanced Blue Diamond Condensate Pump w/ Reservoir & Sensor ❑ X87-835 - 110 to 250V MaxiBlue Advanced Blue Diamond Mini Condensate Pump w/ Reservoir & Sensor (110V) up to 48,000 Btu/h [recommended] ❑ X87-711 - 110V Advanced Blue Diamond Mini Condensate Pump w/ Reservoir & Sensor (2081230V) [recommended] ❑ X87-721 - 208/230V MicroBlue Blue Diamond Mini Condensate Pump (110/2081230V) up to 18,000 Btu/h ❑ X85-003 Fascia Kit for MicroBlue Pump — mounts the MicroBlue and sensor directly beneath the indoor unit ❑ T18-016 Drain Pan Level Sensor ❑ DPLS2 (30A/600V/UL) [fits 2" X 4" utility box] - Black ❑ TAZ-MS303 (30A/600V/UL) [fits 2" X 4" utility box] - White ❑ TAZ-MS303W MegUlreS 1VIAU-MO t--t z Allows indoor units to connect to an MA Controller Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. t 9-I/8 3/16 Indoor u 1-3/4 1-15/161 24-3/85 I/8 2 3/16 115/16 I 11I �tT Imo_-3/I-6 FORM# MSZ-GL06NA FOR MXZ-C MULTI -ZONE HEAT PUMP SYSTEMS - 201902 Unit: inch fin Air in Insulation 01 - 318 O.D 9 Liquid line o1/4 19- 11/16 (Flared connection o1/4) a- Gas line o3/8 16 -15/16 (Flared connection: o3/8 (GL06109112NA), o1/2 (GL15NA)) Drain hose Insulation o1-1/8 O.D Connected part o5/8 O.D WtMRSUBISHI ELECTRIC COOLING & HEATING 1340 Satellite Boulevard, Suwanee, GA 30024 Toll Free: 800-4334822 www.mehvac.com 0. Intertek Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.