APPROVED BLD FIR PLN_BLD2020-0440 ARCHITECTURAL PLANSGENERAL NOTES GENERAL REQUIREMENTS ALL WORK SHALL COMPLY WITH THE 2015 EDITION OF THE INTERNATIONAL BUILDING CODE (STRUCTURAL DESIGN), INTERNATIONAL RESIDENTIAL CODE (ORDINANCE), MOST RECENT EDITION OF THE UNIFORM PLUMBING CODE, INTERNATIONAL MECHANICAL CODE, NATIONAL ELECTRIC CODE, WASHINGTON STATE ENERGY CODE, ANY STATE AND LOCAL AMENDMENTS. AND ANY APPLICABLE LAND USE CODE. THE OWNER/BUILDER SHALL BE RESPONSIBLE FOR DEVELOPING CONSTRUCTION DETAILS NECESSARY TO CONSTRUCT A WEATHER TIGHT, DURABLE BUILDING. ALL FLASHING, WEATHERPROOFING, ROOFING AND WATERPROOFING DETAILS AND CONSTRUCTION OF THESE DETAIL ASSEMBLIES ARE THE FULL AND COMPLETE RESPONSIBILITY OF THE OWNER/BUILDER AND THESE DETAILS SHALL BE CONSTRUCTED PER MANUFACTURER REQUIREMENTS, BUILDING CODE REQUIREMENTS AND ACCEPTED INDUSTRY STANDARDS FOR PERFORMANCE. THE DESIGNER HAS NOT BEEN CONTRACTED TO PERFORM CONSTRUCTION ADMINISTRATION SERVICES OR CONSTRUCTION OBSERVATION SERVICES FOR THIS PROJECT AND IS NOT LIABLE OR RESPONSIBLE FOR DETERMINING ADEQUACY OF CONSTRUCTION OF BUILDING ENVELOPE OR DETAILS. THE OWNER/BUILDER SHALL BE RESPONSIBLE FOR INSPECTING AND VERIFYING THAT ALL FLASHING, WEATHERPROOFING, ROOFING AND WATERPROOFING DETAILS ARE BUILT CORRECTLY AND MEET OWNER/BUILDER'S APPROVAL BEFORE BEING COVERED BY SUBSEQUENT CONSTRUCTION WORK. USE OF THESE PLANS BY ANYONE OTHER THAN THE INTENDED OWNER/BUILDER IS NOT PERMITTED. ANY REDUNDANCY BETWEEN THESE NOTES AND S-SHEETS THE S-SHEETS SHALL SUPERSEDE. SITE WORK 1. BACKFILL FOUNDATION DRAIN AT PERIMETER OF BUILDING WITH COURSE GRANULAR FILL. (1 1/2-3/8 CLEAN WASHED ROCK WITH MIN. 12" WIDE BLANKET EXTENDING TO FINISHED GRADE.) PROTECT DRAIN TILE AND WATERPROOFING. 2. ROUGH GRADING SHALL PROVIDE POSITIVE DRAINAGE AWAY FROM BUILDING. TRENCH TO ELEVATIONS BELOW FROST LINE FOR STORM DRAINS, WATER LINES, SEWERS, AND IRRIGATION SLEEVES. 3. PROVIDE PERFORATED PLASTIC PIPE FOUNDATION DRAINS WHERE SHOWN IN DRAWINGS. CONNECT TO ROOF AND STORM WATER SYSTEM. IN JURISDICTIONS REQUIRING SEPARATE ROOF DRAIN LINES, PROVIDE TIGHT LINE CONNECTED TO ROOF DRAINS IN ADDITION TO PERFORATED DRAIN LINES. 4. ROCKERIES AND RETAINING WALLS SHALL BE DESIGNED BY A LICENSED ENGINEER AND INSTALLED PER APPLICABLE CODE. AREA CALCULATIONS HEATED AREAS - MAIN HOUSE 2ND FLOOR MAIN FLOOR TOTAL HEATED AREAS - A.D.U. 2ND FLOOR MAIN FLOOR TOTAL SMALL GARAGE SHOP COVERED BACK PATIO COVERED FRONT PORCH SQUARE FOOTAGE 1615 1547 3162 727 70 797 315 1324 473 266 DRAWING INDEX MECHANICAL 1. PLUMBING SYSTEMS SHALL BE DESIGNED AND INSTALLED BY A COMPETENT, EXPERIENCED PLUMBER AND IN SHEET NO. DESCRIPTION ACCORDANCE WITH THE UNIFORM PLUMBING CODE AND LOCAL CODES. Al COVER SHEET, INDEX, GENERAL NOTES 2. HVAC SYSTEMS SHALL BE DESIGNED AND INSTALLED BY A COMPETENT AND EXPERIENCED MECHANICAL A2 ENERGY CALCULATIONS CONTRACTOR IN ACCORDANCE WITH THE INTERNATIONAL MECHANICAL CODE, 2015 IRC, AND LOCAL CODES. A3 ELEVATIONS PROVIDE DOCUMENTATION OF FURNACE A.F.U.E. DUCTWORK INSULATION SHALL CONFORM TO THE WASHINGTON STATE ENERGY CODE. WHEN INSTALLED IN GARAGE, HEATING UNITS SHALL BE PLACED SUCH A4 ELEVATIONS THAT ALL PILOT LIGHTS, BURNERS, HEATING ELEMENTS, OR SWITCHES ARE LOCATED A MIN. OF 18" ABOVE THE A5 MAIN FLOOR PLAN GARAGE FLOOR. A6 2ND FLOOR PLAN A7 BUILDING CROSS SECTION/ MISC. DETAILS THERMAL AND MOISTURE S1 STRUCTURAL NOTES/SCHEDULES S2 STRUCTURAL DETAILS 1. INSULATION REQUIREMENTS SHALL MEET OR EXCEED THE LATEST EDITION OF THE WASHINGTON ENERGY CODE S3 BUILDING CROSS SECTION, SHEARWALL & HOLDOWN LOCATIONS OR ENERGY CODE ADOPTED BY THE LOCAL JURISDICTION. INSULATION REQUIREMENTS SHALL BE SHOWN ON S4 FOUNDATION PLAN PLANS OR ON A SEPARATE ENERGY CALCULATION SHEET. 2. APPLY 1 COAT (MIN) HEAVY BODIED ASPHALT BITUMINOUS DAMPPROFING TO EXTERIOR OF FOUNDATION S5 MAIN FLOOR FRAMING WALLS, FROM FOOTING TO FINISHED GRADE AT FOUNDATION WALLS THAT RETAIN EARTH AND ENCLOSE S6 2ND FLOOR FRAMING INTERIOR SPACES AND FLOORS BELOW GRADE.. (R406.1) 3. APPLY APPROPRIATE WATER REPELLENTS TO ANY MASONRY, CEMENT, PLASTER, OR STUCCO PER S7 ROOF PLAN MANUFACTURER'S INSTRUCTIONS. 4. PROVIDE 6 MIL BLACK POLYETHYLENE VAPOR BARRIER IN ALL CRAWLSPACE AREAS, LAPPED AT ALL SPLICES AND OVER FOOTINGS. FINISHES GARAGE CEILINGS BENEATH HABITABLE SPACES SHALL BE COVERED WITH 5/81, TYPE "X" GYPSUM WALL BOARD. GARAGE CEILINGS BENEATH ATTIC OR NON LIVING SPACE SHALL BE COVER WITH 5/81' GYPSUM WALL BOARD. WALLS AND STRUCTURE SEPARATING RESIDENTIAL AND GARAGE SPACES SHALL BE COVERED WITH 1/2" GYPSUM WALL BOARD. ALL GARAGE GYPSUM WALLBOARD SHALL HAVE JOINTS FIRETAPED WITH NAILS SET AND COMPOUNDED. ALL OTHER WALLS SHALL RECEIVE 1/2" GYPSUM WALLBOARD. CEILINGS WITH JOISTS/ TRUSS SPACES GREATER THAN 16" SHALL RECEIVE 5/8" GYPSUM WALLBOARD OR 1/2" GYPSUM CEILING BOARD. WALLS SURROUNDING TUBS OR SHOWERS SHALL BE COVERED WITH WATER-RESISTANT GYPSUM WALL BOARD. WATER- PROOF SURFACE TO A HEIGHT OF 72" ABOVE ADJACENT FLOOR. ANY CEMENT PLASTER OR STUCCO SHALL BE INSTALLED IN ACCORDANCE WITH NORTHWEST WALL AND CEILING BUREAU RECOMMENDATIONS FOR MATERIALS, BACKING, LATH, APPLICATION TECHNIQUES, AND FINISHES. ELECTRICAL SYSTEMS SHALL BE DESIGNED AND INSTALLED BY A COMPETENT AND EXPERIENCED ELECTRICAL CONTRACTOR IN ACCORDANCE WITH MOST CURENT STATE AND LOCAL ELECTRICAL CODE. ELECTRICAL SCHEMATICS PROVIDED IN THIS SET OF PLANS ARE FOR REFERENCE LAYOUT ONLY. FIRESTOPPING FIRESTOPPING SHALL BE PROVIDED TO CUT OFF ALL CONCEALED DRAFT OPENINGS (BOTH VERTICAL AND HORIZONTAL) AND TO FORM AN EFFECTIVE FIRE BARRIER BETWEEN STORIES, AND BETWEEN A TOP STORY AND THE ROOF SPACE. FIRESTOPPING SHALL BE PROVIDED IN WOOD FRAME CONSTRUCTION IN THE FOLLOWING LOCATIONS: 1. IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING FURRED SPACES NOT TO EXCEED 10'-0" HORIZONTALLY, AND AT THE CEILING AND FLOOR LEVEL. 2. AT ALL INTERCONNECTIONS BETWEEN CONCEALED VERTICAL AND HORIZONTAL SPACES SUCH AS OCCUR AT SOFFITS, DROP CEILINGS, COVE CEILINGS, ETC. 3. IN CONCEALED SPACES BETWEEN STAIR STRINGERS AT THE TOP AND BOTTOM OF THE RUN AND WALL CAVITIES IN LINE WITH STRINGERS. 4. AT OPENINGS AROUND VENTS, PIPES, DUCTS, CHIMNEYS AND FIREPLACES AT CEILING AND FLOOR LEVEL, WITH NON-COMBUSTABLE MATERIALS. MISCELLANEOUS 1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS, CONDITIONS, ETC. IN THE FIELD PRIOR TO PROCEEDING. 2. VERIFY SIZE AND LOCATION OF ALL OPENINGS IN THE FLOOR, ROOF, AND WALL WITH MECHANICAL AND ELECTRICAL WORK. 3. PROVIDE SMOKE DETECTORS IN ACCORDANCE WITH (R314) SMOKE DETECTORS TO BE HARD WIRED AND INTERCONNECTED. (R314.4, R314.5). A SMOKE DETECTOR SHALL BE INSTALLED IN EACH SLEEPING ROOM AND OUTSIDE EACH SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS. (R314) CARBON MONOXIDE ALARMS SHALL BE INSTALLED OUTSIDE EACH SEPARATE SLEEPING AREA AND IN THE VICINITY OF THE BEDROOMS. (R315) 4. KITCHEN RANGE, DRYER, BATH AND LAUNDRY ROOM VENTILATION DUCTS SHALL TERMINATE OUTSIDE THE BUILDING AND BE EQUIPPED WITH BACK DRAFT DAMPERS. 5. EXTERIOR OPENINGS TO THE WEATHER SHALL BE FLASHED AND COUNTER -FLASHED IN SUCH A MANNER AS TO MAKE THEM WATERPROOF. ROOF FLASHING PER R903. 6. GUARDRAILS TO BE A MIN. OF 36" ABOVE FINISH FLOOR. (R312) (EXCEPTIONS TO COMMERCIAL PER I.B.C.) 7. OPEN GUARDRAILS TO HAVE INTERMEDIATE RAILS OR PICKETS PLACED SUCH THAT A SPHERE 4" IN DIAMETER CANNOT PASS THROUGH. 8. BEDROOM EMERGENCY EGRESS WINDOWS MUST HAVE A MIN. NET CLEAR OPENING OF 5.7 SQ. FT. MINIMUM NET CLEAR OPENABLE WIDTH OF 20" AND MIN. NET CLEAR OPENING HEIGHT OF 24". MAX. FINISHED HEIGHT OF 44" FROM FINISHED FLOOR TO BOTTOM OF CLEAR OPENING (R310.1). RESIDENTIAL SPRINKER REQUIRED AT MAIN HOUSE AND COVERED REAR PATIO. NOT REQUIRED AT ACCESSORY DWELLING UNIT. SYMBOL LEGEND OO CARBON MONOXIDE DETECTOR INTERCONNECTED 110v w/ BATTERY BACKUP C.O. CAN BE COMBINED w/ S.D. O SMOKE DETECTOR INTERCONNECTED 110v w/ BATTERY BACKUP S.D. O EXHAUST FAN (VENT TO OUTSIDE) OKEYNOTE 1t STRUCTURAL POST 101 DOOR SCHEDULE SYMBOL 11 WINDOW SCHEDULE SYMBOL REVISION- SEE DESCRIPTION IN TITLE BLOCK SIIV� DETAIL SYMBOL 1 - SIMILAR DETAIL A101 DETAIL NO. SHEET NO. Sim l A101 BUILDING CROSS SECTION DETAIL NO. SHEET NO. Room name— ROOM NAME ROOM NUMBER (IF SCHEDULED) Know what's b@IOW. STATE LAW REQUIRES THAT YOU CALL BEFORE YOU DIG TO Call before you dig. LOCATE ALL UNDERGROUND UTILITIES. COONS RESIDENCE 8427 202ND STREET S.W., EDMONDS., WA 98026 Approved by Fire ov AFM ..ter_, A residential fire sprinkler system is required. A recommended flow -through design will meet specifications and reduce equipment and continuing maintenance requirements. ECDC19.05.020B2. Provide a minimum combination water service of one inch (1") meter and one and one half (11/2") service line, or show that domestic and fire protection needs can be met with a smaller service. APPROVED PLANS MUST BE ON JOB SITE City of Edmonds Building Department APPROVED Plans ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE City Of Edmonds Building Department Work SFR Address 8427 202ND ST SW Owner --------------------- COONS --------------- pp �---------------------- Approved Date., ------- 02-22-2021 ---------------- Building Official lcemmr &LOONLI�16( Permit Number BLD2020-0440 U Z N 00 M Z Q E J W d m W N GS O _j J JL� U � �o C) (OD Z W O . uJ N m o aa) W m J p W a H E O U C C O N Z N) �o oZ`p Uo�O mo�an N Q- -° N F O pO L p E o s. 55 N_ 2 U.S E w w a E a dy p W w° O O N U E o O, c 3 cm:4 O U W OmL. E 5,��'� F Zno �� mm > E,�a� LU N V00 C) z Q LU U Q 0 Z z O cf) O 0 w LU oc W Co _ w Cj) Z w Z 0� W W 0 0 06 z 0 CV c) CN V a r'- 00 CU c 0 M 0 z PROJECT NO. 200101 REVISED 02/08/21 DESIGNED BY TL DRAWN BY TL & RIM CHECKED BY TL SHEET NO. Al PRINT DATE 2/8/2021 8:22:56 AM RESUB Feb 17 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT W U) Z) 0 z a R301 CLIMATE ZONE THIS PLAN IS DESIGNED FOR CLIMATE ZONE 5 AND MARINE 4 PER TABLE R301.1, 2015 WASHINGTON STATE ENGERY CODE. R402.2 FENESTRATION (PRESCRIPTIVE) R402.3 Fenestration (Prescriptive). In addition to the requirements of Section R402, fenestration shall comply with Sections R402.3.1 through R402.3.6. R402.3.1 U-factor. An area -weighted average of fenestration products shall be permitted to satisfy the U-factor requirements. R402.3.2 Glazed fenestration SHGC. An area -weighted average of fenestration products more than 50 percent glazed shall be permitted to satisfy the SHGC requirements. R402.3.3 Glazed fenestration exemption. Up to 15 square feet (1.4 m2) of glazed fenestration per dwelling unit shall be permitted to be exempt from U-factor and SHGC requirements in Section R402.1.1. This exemption shall not apply to the U- factor alternative approach in Section R402.1.3 and the total UA alternative in Section R402.1.4. R402.3.4 Opaque door exemption. One side -hinged opaque door assembly up to 24 square feet (2.22 m2) in area is exempted from the U-factor requirement in Section R402.1.1. This exemption shall not apply to the U-factor alternative approach in Section R402.1.3 and the total UA alternative in Section R402.1.4 R404.1 LIGHTING EFFICACY MIN. OF 75%OF LAMPS IN PERMANENTLY INSTALLED FIXTURES SHALL BE HIGH EFFICACY LAMPS. M 1507 MECHANICAL VENTILATION M1507.3.1 SYSTEM DESIGN. EACH DWELLING UNIT OR GUESTROOM SHALL BE EQUIPPED WITH A VENTILATION SYSTEM COMPLYING WITH SECTION M1507.3.4, M1507.3.5, M1507.3.6 OR M1507.3.7. COMPLIANCE IS ALSO PERMITTED TO BE DEMONSTRATED THROUGH COMPLIANCE WITH THE INTERNATIONAL MECHANICAL CODE. M1507.3.2 CONTROL AND OPERATION. 1. LOCATION OF CONTROLS. CONTROLS FOR ALL VENTILATION SYSTEMS SHALL BE READILY ACCESSIBLE BY THE OCCUPANT. 2. INSTRUCTIONS. OPERATING INSTRUCTIONS FOR WHOLE -HOUSE VENTILATION SYSTEMS SHALL BE PROVIDED TO THE OCCUPANT BY THE INSTALLER OF THE SYSTEM. 3. LOCAL EXHAUST SYSTEMS. LOCAL EXHAUST SYSTEMS SHALL BE CONTROLLED BY MANUAL SWITCHES, DEHUMIDISTATS, TIMERS, OR OTHER APPROVED MEANS. 4. CONTINUOUS WHOLE -HOUSE VENTILATION SYSTEMS. CONTINUOUS WHOLE -HOUSE VENTILATION SYSTEMS SHALL OPERATE CONTINUOUSLY. EXHAUST FANS, FORCED -AIR SYSTEM FANS, OR SUPPLY FANS SHALL BE EQUIPPED WITH "FAN ON" AS OVERRIDE CONTROLS. CONTROLS SHALL BE CAPABLE OF OPERATING THE VENTILATION SYSTEM WITHOUT ENERGIZING OTHER ENERGY -CONSUMING APPLIANCES. A LABEL SHALL BE AFFIXED TO THE CONTROLS THAT READS "WHOLE HOUSE VENTILATION (SEE OPERATING INSTRUCTIONS)." 5. INTERMITTENT WHOLE -HOUSE VENTILATION SYSTEMS. INTERMITTENT WHOLE -HOUSE VENTILATION SYSTEMS SHALL COMPLY WITH THE FOLLOWING: 5.1. THEY SHALL BE CAPABLE OF OPERATING INTERMITTENTLY AND CONTINUOUSLY. 5.2. THEY SHALL HAVE CONTROLS CAPABLE OF OPERATING THE EXHAUST FANS, FORCED -AIR SYSTEM FANS, OR SUPPLY FANS WITHOUT ENERGIZING OTHER ENERGY -CONSUMING APPLIANCES. 5.3. THE VENTILATION RATE SHALL BE ADJUSTED ACCORDING TO THE EXCEPTION IN SECTION 403.8.5.1. 5.4. THE SYSTEM SHALL BE DESIGNED SO THAT IT CAN OPERATE AUTOMATICALLY BASED ON THE TYPE OF CONTROL TIMER INSTALLED. 5.5. THE INTERMITTENT MECHANICAL VENTILATION SYSTEM SHALL OPERATE AT LEAST ONE HOUR OUT OF EVERY FOUR. 5.6. THE SYSTEM SHALL HAVE A MANUAL CONTROL AND AUTOMATIC CONTROL, SUCH AS A 24-HOUR CLOCK TIMER. 5.7. AT THE TIME OF FINAL INSPECTION, THE AUTOMATIC CONTROL SHALL BE SET TO OPERATE THE WHOLE -HOUSE FAN ACCORDING TO THE SCHEDULE USED TO CALCULATE THE WHOLE -HOUSE FAN SIZING. M1507.3.4 WHOLE -HOUSE VENTILATION USING EXHAUST FANS. THIS SECTION ESTABLISHES MINIMUM PRESCRIPTIVE REQUIREMENTS FOR WHOLE -HOUSE VENTILATION SYSTEMS USING EXHAUST FANS. A SYSTEM WHICH MEETS ALL THE REQUIREMENTS OF THIS SECTION SHALL BE DEEMED TO SATISFY THE REQUIREMENTS FOR A WHOLE -HOUSE VENTILATION SYSTEM. M1507.3.4.1 WHOLE -HOUSE VENTILATION FANS. EXHAUST FANS PROVIDING WHOLE -HOUSE VENTILATION SHALL HAVE A FLOW RATING AT 0.25 INCHES WATER GAUGE AS SPECIFIED IN TABLE M1507.3.3(1). MANUFACTURERS' FAN FLOW RATINGS SHALL BE DETERMINED ACCORDING TO HVI 916 OR AMCA 210. M1507.3.4.2 FAN NOISE. WHOLE -HOUSE FANS LOCATED 4 FEET OR LESS FROM THE INTERIOR GRILLE SHALL HAVE A SONE RATING OF 1.0 OR LESS MEASURED AT 0.1 INCHES WATER GAUGE. MANUFACTURER'S NOISE RATINGS SHALL BE DETERMINED AS PER HVI 915 (MARCH 2O09). REMOTELY MOUNTED FANS SHALL BE ACOUSTICALLY ISOLATED FROM THE STRUCTURAL ELEMENTS OF THE BUILDING AND FROM ATTACHED DUCT WORK USING INSULATED FLEXIBLE DUCT OR OTHER APPROVED MATERIAL. M1507.3.4.3 FAN CONTROLS. THE WHOLE -HOUSE VENTILATION FAN SHALL MEET THE REQUIREMENTS OF SECTION M1507.3.2 AND M1507.3.2.1. M1507.3.4.4 OUTDOOR AIR INLETS. OUTDOOR AIR SHALL BE DISTRIBUTED TO EACH HABITABLE SPACE BY INDIVIDUAL OUTDOOR AIR INLETS. WHERE OUTDOOR AIR SUPPLIES ARE SEPARATED FROM EXHAUST POINTS BY DOORS, PROVISIONS SHALL BE MADE TO ENSURE AIR FLOW BY INSTALLATION OF DISTRIBUTION DUCTS, UNDERCUTTING DOORS, INSTALLATION OF GRILLES, TRANSOMS, OR SIMILAR MEANS. DOORS SHALL BE UNDERCUT TO A MINIMUM OF 1/2 INCH ABOVE THE SURFACE OF THE FINISH FLOOR COVERING. INDIVIDUAL ROOM OUTDOOR AIR INLETS SHALL: 1. HAVE CONTROLLABLE AND SECURE OPENINGS; 2. BE SLEEVED OR OTHERWISE DESIGNED SO AS NOT TO COMPROMISE THE THERMAL PROPERTIES OF THE WALL OR WINDOW IN WHICH THEY ARE PLACED; 3. PROVIDE NOT LESS THAN 4 SQUARE INCHES OF NET FREE AREA OF OPENING FOR EACH HABITABLE SPACE. ANY INLET OR COMBINATION OF INLETS WHICH PROVIDE 10 CFM AT 10 PASCALS ARE DEEMED EQUIVALENT TO 4 SQUARE INCHES NET FREE AREA. INLETS SHALL BE SCREENED OR OTHERWISE PROTECTED FROM ENTRY BY LEAVES OR OTHER MATERIAL. OUTDOOR AIR INLETS SHALL BE LOCATED SO AS NOT TO TAKE AIR FROM THE FOLLOWING AREAS: 1. CLOSER THAN 10 FEET FROM AN APPLIANCE VENT OUTLET, UNLESS SUCH VENT OUTLET IS 3 FEET ABOVE THE OUTDOOR AIR INLET. 2. WHERE IT WILL PICK UP OBJECTIONABLE ODORS, FUMES OR FLAMMABLE VAPORS. 3. A HAZARDOUS OR UNSANITARY LOCATION. 4. A ROOM OR SPACE HAVING ANY FUEL -BURNING APPLIANCES THEREIN. 5. CLOSER THAN 10 FEET FROM A VENT OPENING OF A PLUMBING DRAINAGE SYSTEM UNLESS THE VENT OPENING IS AT LEAST 3 FEET ABOVE THE AIR INLET. 6. ATTIC, CRAWL SPACES, OR GARAGES. TABLE 1507.3.3 (1) CONTINUOUS WHOLE HOUSE MECHANICAL VENTILATION SYSTEM AIRFLOW RATES FLOOR AREA BEDROOMS* (SQ. FT.) 0-1 2-3 4-5 6-7 >7 < 1500 30 45 60 75 90 (IN CFM's) 1501-3000 45 60 75 90 105 3001-4500 60 75 90 105 120 4501-6000 75 90 105 120 120 135 135 6001-7500 90 105 150 >7500 105 120 135 150 165 TABLE 1507.3.3 (2) INTERMITTENT WHOLE HOUSE MECHANICAL VENTILATION RATE FACTORS RUN-TIME PERCENTAGE IN EACH 4-HOUR SEGMENT 25% 33% 50% 66% 75% 100% FACTOR 4 3 2 1.5 1.3 1.0 THIS PLAN USES AN INTERMITTENT WHOLE HOUSE VENTILATION SYSTEM WITH TIMER(S). TOTAL HEATED FLOOR AREA = 3157 SQ. FT. BEDROOMS = 4 WHOLE HOUSE VENTILATION SIZE = 90 CFM X 4 (25% PER 4-HOUR) = 360 TOTAL CFM FAN(s) SIZE. INTEGRATED FURNACE OUTSIDE AIR INTAKE WITH EXHAUST FANS AS NOTED IN PLAN. MULTIPLE WHOLE HOUSE VENTILATION FANS TO BE INTERCONNECTED TO OPERATE SIMULTANEOUSLY. USE (2) 180 CFM WHOLE HOUSE FANS INTERCONNECTED w/ TIMER CONTROL AT 2ND FLOOR BATH. TOTAL HEATED FLOOR AREA = 797 SQ. FT. BEDROOMS = 1 WHOLE HOUSE VENTILATION SIZE = 30 CFM X 4 (25% PER 4-HOUR) = 120 TOTAL CFM FAN(s) SIZE. INTEGRATED FURNACE OUTSIDE AIR INTAKE WITH EXHAUST FANS AS NOTED IN PLAN. MULTIPLE WHOLE HOUSE VENTILATION FANS TO BE INTERCONNECTED TO OPERATE SIMULTANEOUSLY. 2015 WASHINGTON STATE ENERGY CODE MISC. ENERGY CODE NOTES A permanent certificate shall be completed and posted on or within three feet of the electrical distribution panel b the builder or registered P P P P Y 9 design professional. The certificate shall be completed by the builder or registered design professional and shall not cover or obstruct the visibility of the circuit directory label, service disconnect label or other required labels. The certificate shall list the predominant R-values of insulation installed in or on ceiling/roof, walls, foundation (slab, below -grade wall, and/or floor) and ducts outside conditioned spaces; U- factors for fenestration and the solar heat gain coefficient (SHGC) of fenestration, and the results from any required duct system and building envelope air leakage testing done on the building. Where there is more than one value for each component, the certificate shall list the value covering the largest area. The certificate shall list the types and efficiencies of heating, cooling and service water heating equipment. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour. Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g. (50 Pascals).W here required by the code official, testing shall be conducted by an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. Where the primary heating system is a forced -air furnace, at least one thermostat per dwelling unit shall be capable of controlling the heating and cooling system on a daily schedule to maintain different temperature set points at different times of the day. Specifics and Exceptions see SEC. DUCT SEALING AND TESTING All ductwork shall be sealed and tested per R403.2.2. FENESTRATION ALL FENESTRATION SHALL BE N.F.R.C. CERTIFIED WHOLE HOUSE FANS Whole house ventilation fans shall be installed so as to run simultaniously. EXHAUSTFANS Exhaust fans to terminate at building exterior with clearances per SRC M1506.2 (min. 3 ft to openings) and for clothes dryer vent terminations to be per M1502.3 (3 ft to bldg. openings). ALL FENESTRATION SHALL BE NFRC CERTIFIED. 2x6 TOP PLATES Q.W.B. 3ID R-10 INSULATION ALLIED IN CAVITY BETWEEN )ER AND INTERIOR G.W.B. )ER PER PLAN yyttyJOW FINISH AND TRIM PER MISC. DETAILS. TY.P. HEADE.RI.NSULATION 1 1 /211 = 1 I_011 FENENSTRATION CALCULATIONS AD U GLAZING 70 SF LESS EXEMPT GLAZING -00 SF PLUS GLAZED DOORS 24 SF PLUS OTHER EXTERIOR DOORS 21 SF TOTAL FENESTRATION: 115 SF FENENSTRATION CALCULATIONS MAIN HOUSE GLAZING 478 SF LESS EXEMPT GLAZING -00 SF PLUS GLAZED DOORS 24 SF PLUS OTHER EXTERIOR DOORS 45 SF NOTE: SEE SHEET A7 FOR ADDITIONAL INSULATION LOCATIONS AND DETAILS. PRESCRIPTIVE ENERGY CODE - MAIN HOUSE HEATING SIZE - MAIN HOUSE Prescriptive Energy Code Compliance for All Climate Zones in Washington Project Information Contact Information COONS RESIDENCE - MAIN HOUSE MARK & JENNIFER COONS This project will use the requirements of the Prescriptive Path below and incorporate the the minimum values listed. In addition, based on the size of the structure, the appropriate number of additional credits are checked as chosen by the permit applicant. Authorized Representative - - - - - - - - - - - - - - - Date --------------------------- All Climate Zones R-Value' U-Factory Fenestration U-Factor' n/a 0.30 Skylight U-Factor n/a 0.50 Glazed Fenestration SHGC'' n/a n/a Ceiling' 49' 0.026 Wood Frame Wallg` u 21 int 0.056 Mass Wall R-Value' 21/21h 0.056 Floor 30g 0.029 Below Grade Wall- 10/15/21 int + TB 0.042 Slabd R-Value & Depth 10, 2 ft n/a I able K4U2.1.1 ana I able K4U2A.3 rOOmotes mciucea on rage z. Each dwelling unit in a residential building shall comply with sufficient options from Table R406.2 so as to achieve the following minimum number of credits: 1. Small Dwelling Unit: 1.5 credits ❑ Dwelling units less than 1500 square feet in conditioned floor area with less than 300 square feet of fenestration area. Additions to existing building that are greater than 500 square feet of heated floor area but less than 1500 square feet. 212. Medium Dwelling Unit: 3.5 credits All dwelling units that are not included in #1 or #3. Exception: Dwelling units serving R-2 occupancies shall require 2.5 credits. ❑ 3. Large Dwelling Unit: 4.5 credits Dwelling units exceeding 5000 square feet of conditioned floor area. ❑ 4. Additions less than 500 square feet: .5 credits Table R406.2 Summary 0ntion Descrintion Credits) 1a Efficient Building Envelope 1a 0.5 lb Efficient Building Envelope 1 b 1.0 1c Efficient Building Envelope 1c 2.0 1d Efficient Building Envelope 1d 0.5 2a Air Leakage Control and Efficient Ventilation 2a 0.5 2b Air Leakage Control and Efficient Ventilation 2b 1.0 2c Air Leakage Control and Efficient Ventilation 2c 1.5 3a High Efficiency HVAC 3a 1.0 3b High Efficiency HVAC 3b 1.0 3c High Efficiency HVAC 3c 1.5 3d High Efficiency HVAC 3d 1.0 4 High Efficiency HVAC Distribution System 1.0 5a Efficient Water Heating 5a 0.5 5b Efficient Water Heating 5b 1.0 5c Efficient Water Heating 5c 1.5 5d Efficient Water Heating 5d 0.5 6 Renewable Electric Energy 0.5 Total Credits *Please refer to Table R406.2 for complete option descriptions Lj El El O 0.5 El El p 1.0 11 13 El p 0.5 11 0 1.5 El *1200 kWh 0.0 3.50 imple Heating System Size: Washington State its heating system sizing calculator is based on the Prescriptive Requirements of the 2015 Washington State Energy Code (WSEC) and ACCA anuals J and S. This calculator will calculate heating loads only. ACCA procedures for sizing cooling systems should be used to determine cooling ads. ease fill out all of the green drop -downs and boxes that are applicable to your project. As you make selections in the drop -downs for each section, )me values will be calculated for you. If you do not see the selection you need in the drop -down options, please call the WSU Energy Extension ogram at (360) 956-2042 for assistance. Project Information Contact Information COONS RESIDENCE - MAIN HOUSE IMARK & JENNIFER COONS Heating System Tvpe: O All Other systems 0 Heat Pump To see detailed instructions for each section, place your cursor on the word "Instructions'. Design Temperature Instructions j Design Temperature Difference (AT) 46 EdmoMs j nT = Indoor (70 degrees) - Outdoor Design Temp Area of Building Conditioned Floor Area Instructions Conditioned Floor Area (sq ft) 3,162 Average Ceiling Height Conditioned Volume Instructions Average Ceiling Height (ft) 8.7 27,509 Glazing and Doors U-Factor X Area = UA Instructions u-o Bo 0.300 547 164.10 Skylights U-Factor X Area = UA n,struceons 0.50 0� --- Insulation Attic U-Factor X Area = UA Instructions `Rya -.� 0.026 1,858 48.31 Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA Instructions No Vaulted Ceilings in this project. Above Grade Walls (see Figure 1) U-Factor X Area UA _ Instructions R-21 Intermediate . l 0.056 4,300 240.80 Floors U-Factor X Area UA Instructions ( l 0.029 1,873 54.32 R-30 Below Grade Walls is -Fig- 1)1) U-Factor X Area UA Instructions "de 0.028 0� No walls in this project. .. Slab Below Grade sasFi ure i F-Factor X Length UA Instructions , 0.303 0� --- No Slab Below Grade in this project. . Slab on Grade (se.F ure i) F-Factor X Length UA Instructions l No Slab on Grade in this project. . -------- Location of Ducts Instructions Duct Leakage Coefficient Unconditioned Space - 1.10 Sum of UA 507.53 Envelope Heat Load 23,346 Btu / Hour Fioure 1. Sum of ua X AT Air Leakage Heat Load VolumeX 0,6XDTX.018 13,667 Btu / Hour Above Gratle Building Design Heat Load 37,013 Btu / Hour Air Leakage + Envelope Heat Loss Building and Duct Heat Load 40,714 Btu / Hour Ducts in unconditioned space: Sum of Building Heat Loss X 1,10 Ducts in conditioned space: Sum of Building Heat Loss X i Maximum Heat Equipment Output 50,893 Btu / Hour Building and Duct Heat Loss X 140 for Forced Air Furnace Building a,d Duct Heat Loss X 1.25 for Heat Pump (07101113) ENERGY CREDITS 2a AIR LEAKAGE CONTROL AND EFFICIENT VENTILATION )a: 0.5 �• Compliance based oil R402.4.1.�. Reduce the tested au' leakage _ .0 all• changes per P ' � p hour maxiintim and All whole house ventilation requirements as determined by Section N11507.3 of the International Residential Corte shall be met with a high efficiency fan (maxilnlun 0.35 watt.s./cfin), not interlocked with the fin- lace fail. Ventilation systems using a Airnace including an ECM motor are allowed, provided that they are controlled to operate at low. speed in ventilation only mode. To qualify to claim this credit, the building permit drawings shall specify the option being selected and shall specify the inaximmu tested btlllding air leakage and shall show the qualifying ventilation system. 3a HIGH EFFICIENCY HVAC EQUIPR•IENT 3a: 1.0 Gas. propane or oil -fired furnace with miniinuin AFLJE of 94%, or Gas, propane or oiled -fired boiler with mininlain AF't?E of 92° o To qualify to claiin this credit, the building permit drawings shall specify the option benig selected and shall specify the heating egttlpment Type and the mininmin e iii inent efficiency. 5a EFFICIENT «ATER HEATING 5a: C).5 All showerhead and kitchen sink faucets installed in the hotise shall be rated at 1.75 GPM or less. All other lavatory faucets shall be rated at 1.0 GPM or less.` To qualify to claim this credit, the building permit drawings shall specify the option being selected and shall specify the inaxinuini flow rates for all showerheads, kitchen sink faiicets. and other Iavatoiv faucets. 5c EFFIC'IENT WATER HEATING 5c: 1.5 Water heating system shall inchide one of the following: Gas, propane or oil water heater with a ininimtim EF of 0.91 01' Solar water heating stipplementing a miniumin standard water heater. Solar water heating Grill provide a rated minimum savings of 85 theinis or 2000 kNX1 based oil the Solar Rating and Certification Corporation (SRCC) Annual Performance of OG-300 Certified Solar Water Heating Systems 01' Electric heat pump water heater with a rluniinum EF of 2.0 and meeting the standards ofNEEA's Northern Climate Specifications for Heat Ptinlp Water Heaters To gtialify to claim this credit, the building permit drawings shall specify the option being selected and shall specify the water heater equipment type and the minimum equipment efficiency and, for solar water heating systems, the calculation of the niinimiim enemy saviii2s. PRESCRIPTIVE ENERGY CODE - A.D.U. Prescriptive Energy Code Compliance for All Climate Zones in Washington P 9Y P 9 Project Information Contact Information COONS RESIDENCE - ASSESSORY DWELLING MARK & JENNIFER COONS This project will use the requirements of the Prescriptive Path below and incorporate the P l q P P the minimum values listed. In addition, based on the size of the structure, the appropriate number of additional credits are checked as chosen by the permit applicant. Authorized Representative __________________________________________ Date ___________________________ All Climate Zones R-Valuey U-Factory Fenestration U-Factor' n/a 0.30 Skylight U-Factor n/a 0.50 Glazed Fenestration SHGC"' n/a n/a Ceiling' 49 0.026 Wood Frame wallgm'° 21 int 0.056 Mass Wall R-Value' 21/21' 0.056 Floor 30' 0.029 Below Grade Wallc'm 10/15/21 int +TB 0.042 Slab' R-Value & Depth 10, 2 ft n/a I able K4U2.1.1 and able K4U2.1.3 l-ootnotes Included on Page 2. Each dwelling unit in a residential building shall comply with sufficient options from Table R406.2 so as to achieve the following minimum number of credits: 1. Small Dwelling Unit: 1.5 credits O Dwelling units less than 1500 square feet in conditioned floor area with less than 300 square feet of fenestration area. Additions to existing building that are greater than 500 square feet of heated floor area but less than 1500 square feet. ❑ 2. Medium Dwelling Unit: 3.5 credits All dwelling units that are not included in #1 or #3. Exception: Dwelling units serving R-2 occupancies shall require 2.5 credits. ❑ 3. Large Dwelling Unit: 4.5 credits Dwelling units exceeding 5000 square feet of conditioned floor area. ❑ 4. Additions less than 500 square feet: .5 credits Table R406.2 Summary Ontinn nascrintinn (� rllt(Ci 1a Efficient Building Envelope 1a 0.5 1b Efficient Building Envelope 1b 1.0 1c Efficient Building Envelope 1c 2.0 1d Efficient Building Envelope 1d 0.5 2a Air Leakage Control and Efficient Ventilation 2a 0.5 2b Air Leakage Control and Efficient Ventilation 2b 1.0 2c Air Leakage Control and Efficient Ventilation 2c 1.5 3a High Efficiency HVAC 3a 1.0 3b High Efficiency HVAC 3b 1.0 3c High Efficiency HVAC 3c 1.5 3d High Efficiency HVAC 3d 1.0 4 High Efficiency HVAC Distribution System 1.0 5a Efficient Water Heating 5a 0.5 5b Efficient Water Heating 5b 1.0 5c Efficient Water Heating 5c 1.5 5d Efficient Water Heating 5d 0.5 6 Renewable Electric Energy 0.5 Total Credits *Please refer to Table R406.2 for complete option descriptions El El El El El El O 1.5 11 *1200 kWh 0.0 1.50 Sim HEATING SIZE - A.D.U. Size: Washinaton State Please fill out all of the green drop -downs and boxes that area applicable to our project. As you make selections in the drop -downs for each section 9 P PP Y P 1 Y P some values will be calculated for you. If you do not see the selection you need in the drop -down options, please call the WSU Energy Extension Program at (360) 956-2042 for assistance. COONS RESIDENCE -ACCESSORY DWELLING UNIT MARK & JENNIFER COONS Heating System Type: O All Omer systems 0 Heat Pump To see detailed instructions for each section, place your cursor on the word "Instructions'. Design Temperature Instr-tiOrIs Design Temperature Difference (AT) 46 l Edmonds DT = Indoor (70 degrees) - Outdoor Design Temp Area of Building Conditioned Floor Area Instructions Conditioned Floor Area (sq ft) 797 Average Ceiling Height Conditioned Volume Instructions Average Ceiling Height (ft) 7.9 6,296 Glazing and Doors U-Factor X Area = UA Instructions 6u-o.3o . I 0.300 115 34.50 Skylights U-Factor X Area = UA Instructions 0.50 0� --- Insulation Attic U-Factor X Area = UA Instructions L,R49 �', 0.026 727 18.90 Single Rafter or Joist Vaulted Ceilin s U-Factor X Area UA Instructions 0 No Vaulted Ceilings in this project. . --- Above Grade Walls see Figure 1/ U-Factor X Area UA Instructions -R-21 Intermediate .� 0.056 1,209 67.70 Floors U-Factor X Area UA Instructions `30 J 0.029 727 21.08 Below Grade Walls (see Figure 1) U-Factor X Area UA Instructions 0.028 0� No Below Grade Walls in this project. Slab Below Grade (seeFIours 1 F-Factor X Length UA Instructions , 0.303 0� --- No Slab Below Grade in this project. . Slab on Grade (sae Flours i) F-Factor X Length UA Instructions R-10 Fully Insulated , 0.360 39 14.04 Location of Ducts Instructions Duct Leakage Coefficient Unconditioned Space . I 1.10 Sum of UA 156.23 Envelope Heat Load 7,187 Btu / Hour Figure 1. SnmofUAXAT Air Leakage Heat Load VolumeX 0.6XATX.018 3,128 Btu / Hour Above Grade Building Design Heat Load 10,315 Btu / Hour Air Leakage + Envelope Heat Loss Building and Duct Heat Load 11,346 Btu/Hour Ducts in unconditioned space: Sum of Building Heat Loss X 1.10 Ducts m conditioned space: Sum of Building Heat Loss X i Maximum Heat Equipment Output 14,182 Btu / Hour Building and Duct Heat Loss X 1,40 for Forced Air Furnace Building and Duct Heat Loss X 1.25 for Heat Pump (07101113) U Z N co cc C) C) Z < E a 3:° w a I O U J � Ln�o Mew Z co C4 Wco � O W In O W a E 0 U C .� H 0 C 4) U °'aias iu a�-allou, `oo Z ofyo m" c a1 O m m m m ow-- 'Z`o�o202-E-m@umioacim�- Namc'�''OL~O���YUEaai�o =0Q ao-cnS 0 c m cUi 76 `off ami �"u 20,Qz 2��mcy2s �<aSEy aw� :Eo- V).. amicrcn-=°o OLu Uo oL' oUoo.�oc 3c oca UJJi- 5 c aoU �-am mU ya o F oaoa�� ��2oEE� m LU N V 00 Z Q UJi0 Q Z z o ° Cn O o w UJ W 3: W Cn U. Cn Z w Z I..L Z LU U) 0 %0 08 10 N O V Q 00 f6 C O O Z PROJECT NO. 200101 REVISED 12/15/19 DESIGNED BY TL DRAWN BY TL & RM CHECKED BY TL SHEET NO. A2 PRINT DATE 9/4/2020 6:50:17 AM RESUB Feb 17 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT HANDRAIL, GUARD AND BALUSTERS TO CONFORM TO RESIDENTIAL STAIRS TO BE I.R.C. OPENINGS SPACED MIN. 36" (CLR) WIDE. SUCH THAT A 4" SPHERE CANNOT PASS THROUGH. - i 2 CV M z 0 -- 1 1/4" DIA. MIN; 2" DIA. MAX. HANDRAIL w/ RETURNS TO WALL. DBL. JOIST (U.N.O.IN PLAN) 41fol TRIANGLE FORMED BY TREAD AND RISER SHALL NOT ALLOW A 6" SPHERE TO PASS THROUGH. w 10" MIN. \ v CM TREAD II �I FIRE BLOCK BETWEEN STUD 3/4" MIN; BAYS AT WALLS IN CONTACT 1 1/4" MAX. WITH STRINGERS. NOSING 1/2" MIN. PLYWOOD RISERS STAIR DETAIL 3/4" = 1'-0" BASE 4 3/4" & COLUMN- SIMPSON LUS210 JOIST HANGER - SIMPSON A35 EACH SIDE OF STRINGERS - (1) LAYER 1/2" GWB 2x12 STRINGERS PER PLAN APPROVED BY PLANNING MAIN FLOOR AL 101' - 0" Mar 04 2021 Max. He' ht 124' - 10" ru Top of highest ridge 73 95 nnn 41 C I ..i LEI 0 ■i�i■ ni■i■ ■ • • mill ■ ■ ■ 1 I ■ ME ■ ■ �_ �_ ■•I •I ■��■ ■��I■ ■��■ - - - - - - - - - 111111111111 111 I,■��■I 11 111111111111 ■��■ = ��� E ���■ ���IIIIIIIIIIIIIIIIIIIIIIIIIIIIII���IIIC__�l1111111111111 ��� ��� � �--� Gig -■�=_-■�=�■1■ m m:. 1/4" = 1'-0" NORTH ELEVATION % 1/4" = 1'-0" AFT CEILING 5 120' - 0 3/4" OFT FLOOR � 113' - 0 3/4" AGE PLATE 111' - 10" U z N W O W z rn a E a �0 way 5�,�a O -j JL U 2LO� 'n CO 2 z W N .. W 11 .m o W W m O W a F All O H Q) L -Iwo z c, C 0 � OJoyrnQcoa_m mo�m�mR OULL"O "' � ".�. � C y OL �'100• C U O Um £O oCNNWmHC U C oL.2p UU O aw W OEJ 2,NZ a H WN V00 0 z Q Lu u Q 0 Z Z O 75 cj)V O 0 W LU W co W cj) Z Lu Z W Cj 0 0 06 Z CV O V a It 00 0 O Mn 0 z PROJECT NO. 200101 REVISED 02/08/21 DESIGNED BY TL DRAWN BY TL & RM CHECKED BY TL SHEET NO. PRINT DATE 2/8/2021 8:17:53 AM RESUB Feb 17 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Max. Hei ht 124' - 10" Tp of highest ridge 4' - 7 3/4" co j 2ND FLOOR PLATE v 119' - 2 7/8" (ilk 2ND FLOOR 110' - 1 1/8 AIN FLOOR 1 1 ; ��-� .• Ave •• 1 DOOR SCHEDULE SYM. NO. WIDTH HEIGHT COMMENTS MAIN FLOOR D1 3' - 0" 8' - 0" TEMP. GLASS (U=0.30) SOLID CORE ENTRY DOOR w/ TEMP. GLASS LITES PER OWNER SPECS. D2 3' - 0" 8' - 0" D3 10'-0" 8'-0" D4 2' - 8" 8' - 0" 1 3/8" SOLID CORE w/ SELF CLOSING MECHANISM D5 2'-8" 8'-0" D6 5'-0" 8'-0" D7 2'-6" 8'-0" D8 2'-8" 8'-0" D9 2'-6" 8'-0" D10 18'-Off 10'-0" D11 2' - 8" 8' - 0" 1 3/8" SOLID CORE w/ SELF CLOSING MECHANISM D12 3' - 0" 8' - 0" SOLID CORE ENTRY DOOR w/ TEMP. GLASS LITES PER OWNER SPECS. D13 6'-0" 8'-Of' 2ND FLOOR D14 3'-0" 6'-8" D15 2'-6" 6'-8" D16 2'-6" 6'-8" D17 2'-6" 6-8" D18 2'-6" 6-8" D19 2'-6" 6'-8" POCKET DOOR D20 2' - 6" 6' - 8" D21 2'-6" 6'-8" D22 2'-6" 6'-8" D23 5'-0" 6'-8" D24 2'-6" 6-8" D25 2'-8" 6-8" D26 2' - 4" 6' - 8" LOFT FLOOR D27 2'-4" 6'-8" D28 3' - 0" 6' - 8" SOLID CORE DOOR w/ LOCKING DEADBOLT D29 6'-0" 6'-8" D30 5'-0" 6-8" D31 2'-8" 6-8" D32 2'-6" 6'-8" I 1 �1 m ' �M ■ i / LE 1 ■ ■■ ■iiiii=■ ■■ ■ ■■ ■ ■■ ■0■ ■■ ■ ■■ ■ ■■ ■i=■ ■■ ■ ■■ ■ ■■ ■iiiii=■ ■■ ■ ■■ ■ ■■ ■0■ ■■ 1 1 • 1 LOFT CEILING 120' - 0 3/4" 0 M cV LOFT FLOOR I III III III III III III III III III III III III III III III III III III III III III III III III III III III III III- EAST ELEVATION 2 3/16" = 1'-0" WINDOW SCHEDULE SYM. NO. WIDTH HEIGHT AREA TYPE U-VALUE COMMENTS MAIN FLOOR 1 T - 0" 5' - 0" 15 SF SINGLE HUNG 0.30 2 3' - 0" 5' - 0" 15 SF SINGLE HUNG 0.30 0.30 3 4' - 6" 6' - 0" 27 SF PICTURE 4 4' - 6" 6- 0" 27 SF PICTURE 0.30 5 4' - 6" 6' - 0" 27 SF PICTURE 0.30 6 3' - 0" 2' - 0" 6 SF PICTURE 0.30 TEMP. GLASS 7 3' - 0" 2' - 0" 6 SF PICTURE 0.30 TEMP. GLASS 8 3' - 0" 5' - 0" 15 SF CASEMENT - SINGLE 0.30 9 3' - 0" 5' - 0" 15 SF PICTURE 0.30 10 3' - 0" 5' - 0" 15 SF CASEMENT - SINGLE 0.30 11 3' - 0" 5' - 0" 15 SF PICTURE 0.30 12 3' - 0" 3' - 0" 9 SF CASEMENT -SINGLE 0.30 13 3' - 0" 3' - 0" 9 SF CASEMENT -SINGLE 0.30 14 8' - 0" 5' - 0" 40 SF CASEMENT/PICTURE/CASEMENT 0.30 15 2' - 0" 5' - 0" 10 SF SINGLE HUNG 0.30 2ND FLOOR 16 3' - 0" 5' - 0" 15 SF SINGLE HUNG 0.30 17 3' - 0" 5' - 0" 15 SF SINGLE HUNG 0.30 18 5' - 0" 3' - 0" 15 SF SLIDER 0.30 TEMP. GLASS 19 4' - 0" 4' - 0" 16 SF SLIDER 0.30 20 3' - 0" 4' - 0" 12 SF PICTURE 0.30 21 3' - 0" 4' - 0" 12 SF PICTURE 0.30 WINDOW SCHEDULE SYM. NO. WIDTH HEIGHT AREA TYPE U-VALUE COMMENTS 22 3' - 0" 5' - 0" 15 SF SINGLE HUNG 0.30 23 4' - 0" 3' - 0" 12 SF PICTURE 0.30 24 2' - 0" 2' - 0" 4 SF PICTURE 0.30 25 2' - 0" 2' - 0" 4 SF PICTURE 0.30 26 2' - 0" 2' - 0" 4 SF PICTURE 0.30 27 5' - 0" 4' - 0" 20 SF SLIDER 0.30 28 3' - 0" 5' - 0" 15 SF SINGLE HUNG 0.30 29 2' - 0" 3' - 0" 6 SF SINGLE HUNG 0.30 TEMP. GLASS 30 3' - 0" 4' - 0" 12 SF SLIDER 0.30 48" OFF LANDING - (TEMP. GLASS) 31 5' - 0" 5' - 0" 25 SF PICTURE 0.30 32 2' - 4" 5' - 0" 12 SF CASEMENT - SINGLE 0.30 33 2' - 4" 5' - 0" 12 SF CASEMENT - SINGLE 0.30 34 2' - 0" 2' - 0" 4 SF PICTURE 0.30 35 2' - 0" 2' - 0" 4 SF PICTURE 0.30 36 2' - 0" 2' - 0" 4 SF PICTURE 0.30 GARAGE PLATE 37 3' - 0" 5' - 0" 15 SF SINGLE HUNG 0.30 38 3' - 0" 5' - 0" 15 SF SINGLE HUNG 0.30 39 3' - 0" 5' - 0" 15 SF SINGLE HUNG 0.30 40 3' - 0" 5' - 0" 15 SF SINGLE HUNG 0.30 Grand total 548 SF U Z N W O W O Z >Q E Q > U Y 2 0, w a , O "� UJ� M CO Z W N C W m � O W a F E 0 w"A •, _� Zy.y. C L y d a N C CYO 0 0 o Z J p U Cp C L (0 (Up N O E N. 6 Nam C .V :: O L H O p T j J. U Q, y C _ Q p_ "- O a w C C N U~ O a y U O J O y m Q C 0 0- t6 t6 O U._ E N $ O yC olU0 4ya,UWg a0N Uy-3 a� !2OU p c w Omoo N ` S O Eaa-� Z 4) U p E O y Lu N V 00 z Q Lu lv Q 0 Z 7L O 75 cj)V O o W LU oc LU co LL W cj) Z w Z W Cj 0 0 od z CV O V a04 � 0 0 Mn 0 z PROJECT NO. 200101 REVISED 02/08/21 DESIGNED BY TL DRAWN BY TL & RM CHECKED BY TL SHEET NO. PRINT DATE 2/8/2021 8:18:25 AM RESUB Feb 17 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SEE SHEET A4 FOR WIINDOW AND DOOR SCHEDULE 11 10 9 18 7 MAIN FLOOR 1/4" = 1'-0" <k north 14 13 i 18'-6" Ew CE rD MINI -SPLIT HEAT PUMP UNIT FOR A.D.U. 9 OW LI— 22' - 4 1 /4" V 32' - 6" HEAT PUMP 1' - 11 1/2", 3' - 6" 11 N- - - - - - - - - - _7 10 O 1 M - - - - - 11 0 REFRIG. - N - SPACE I � I M � KITCHEN L CV 6 5 4 3 2 1 54' - 0" Sim 4'-9" 5'-6" 4'-9" 1'-6" L, 5'-0" A2 8' - 0 1/2" 2'- 7 1 /4" 2' - 7 1 /4" 12 13 14 N ED CV I I I I I I I I I DINING ROO I I 2'-0" 4'-61/2" 10'-0" GREAT ROOM 0. K — — - D1 — — — — — — — C° - - - DBL. N 02-. . " OVEN 4' - 0. _ I I I I I N COVERED ATIO PANTRY CAB.----------- - `L NN 03 '� 02 D4 °' \` 17 BID M - 01 12'-81/8" �� 7-6" o - - - 5' 0" � BASE AND 00 55 -- 180 CFM WHOLE HOUSE o �ORUMN 12 03 FAN w/ TIMER. ELEVATION B INTERCONNECTED TO _ — — `�4 12' - T' 5' - 11 1/2" 2ND FLOOR BATH. 0 0'- 10 5/8" 58' - 6" = S.D. 3' - 6" 2ND FLOOR ABOVE CD D6 I� 37'-6" 11'-0" 10'-0 GARAGE, S.D. C.O. ENTRY 02 WATER SHUTOFF �2 M 15 5'-0" GUEST ROOM N i 02 I FRO T PORCH SHP/A.D.U. 3'-6" 11'-5N----- - - - - - ---- 2'-8" 6'-2" 4'-0' " 1 NTRY 13 17 D8 06 07 C.O. S.D. Lu— — 12 -- GAS FURNACE --UP---- D13 1i u u 02 - 1 u u u u TANKLESS WATER (1.0 E.C.) rn - - - - -- u u u SYSTEM. USE NAVIAN "' 03 6 , u u u UP 01 ELECT. PANEL RW240 OR EQUIV. - o 08 --� D12 TO ADU 0.91 E.U. E.C. 5b = 1.5 CREDITS) 1 = u WATER SHUTOFF - _ 20' N D7me- 1L----- --- D11 ____------- �_______ 1/2" 02 3'- 6" � W.I.C. 3 �i M -------� F �o TANKLESS WATER I - - - - - - --- SYSTEM. FOR ADU. USE NAVIAN �6 - 6 D3 ELECTRIC 05 u u ii -RW240 OR EQUIV. — —"' — — — — — — PANEL AND METE — — -- ------------ — u — - — —M — ---y a ii a ii p 0.91 E.U. E.C. 5b = 1.5 CREDITS) -----_-- - -_-- - 6x8 STRUCTURAL 1 CRAWLSP CE 27 \ 1/2 GWB POST PER PLAN ACCESS UNDER STAIRS N it 6 1'-9" 10'-0" 1'-9" 5'-4" '-6" 10'-0" 13'-6" i SHOP 5/8" TYPE "X" AT CEILING UNDER HABITABLE SPACE o N ABOVE. � I 42' - 0" CARPORT I � I i I i [ID O M 4 T-6" 2'-8" 14'- 9 1/2" 70' - 6" 01 GARAGE DOOR: PROVIDE 1 3/8" SOLID CORE DOOR OR EQUIV. 20 MIN. RATED FIRE RATED DOOR BETWEEN HOUSE AND GARAGE. DOOR TO BE EQUIPPED WITH A SELF -CLOSING DEVICE. (R302.5.1) 02 LANDINGS: THERE SHALL BE A FLOOR OR LANDING AT EACH SIDE OF EACH EXTERIOR DOOR. LANDING OR FLOOR SHALL BE A MAX. 1.5" LOWER THAN THE TOP OF THE THRESHOLD; 7 3/4" IS PERMITTED AT EXTERIOR DOORS THAT DO NOT SWING OVER THE LANDING. MAX. LANDING SLOPE IS 1/4:12. (R311.3.1 & 311.3.2) 03 GARAGE WALL: SEPARATION FROM GARAGE AND RESIDENCE SHALL HAVE 1/2" GYPSUM BOARD APPLIED TO GARAGE SIDE. A 5/8" TYPE "X" GWB OR EQUIV. IS REQUIRED BETWEEN THE GARAGE AND HABITABLE SPACE ABOVE THE GARAGE. (R302.6 & TABLE 302.6) 04 COOKING APPLIANCES: HOUSHOLD COOKING APPLIANCES SHALL BE LISTED AND LABELED AND INSTALLED IN ACCORDANCE WITH MANUF. SPECS. RANGE HOOD SHALL HAVE LIGHT & 100 CFM MIN. EXHAUST FAN AND BE VENTED TO OUTSIDE WALL. EXAHUST HOOD SYSTEMS IN EXCESS OF 400 CFM SHALL BE PROVIDED WITH MAKE UP AIR IN THE AMOUNT EQUIV. TO THE EXHAUST RATE. (M1503) 05 CRAWLSPACE OPENING: MIN. 18"x24" THROUGH THE FLOOR OR MIN. 16"x24" THROUGH THE PERIMETER WALL. (R408.4) 06 GUARDS SHALL BE REQUIRED AT OPEN SIDED WALKING SURFACES, PORCHES, STAIRS, RAMPS, BALCONIES AND LANDINGS LOCATED MORE THAN 30" ABOVE THE FLOOR OR GRADE BELOW. GUARD SHALL NOT BE LESS THAN 36" IN HEIGHT. OPEN RAILS SHALL HAVE INTERMEDIATE RAILS SPACED SO THAT A 4" SPHERE CANNOT PASS THROUGH. (R312) 07 STAIR TREADS AND RISERS (R311.7): MAX. RISER HEIGHT SHALL BE 7 3/4". RISER SHALL BE MEASURED VERTICALLY BETWEEN LEADING EDGES OF THE ADJACENT TREADS. DIFFERENCE IN RISER HEIGHTS SHALL NOT EXCEED 3/8". THE MIN. TREAD DEPTH SHALL BE 10". DIFFERENCE IN TREAD DEPTH SHALL NOT BE GREATER THAN 3/8". FIREBLOCK STAIRS PER IRC 302.11. ALL STAIRS TO BE PROVIDED WITH A LIGHT AND SWITCH AT TOP AND BOTTOM OF STAIRS (R303.7). STAIR LANDINGS REQUIRED AT TOP AND BOTTOM (311.7.6) 08 EGRESS WINDOWS: OPENINGS ARE REQUIRED FOR ALL SLEEPING ROOMS AND BASEMENTS. BOTTOM OF CLEAR OPENING IS NOT TO EXCEED 44" ABOVE FLOOR. OPENABLE AREA IS 5.7 SQ. FT. NET CLEAR MIN. EXCEPT 5.0 SQ. FT. IS ALLOWED FOR AN OPENING WITHIN 44" OF FINISHED GRADE. (R310.1) 09 DIRECT VENT ZERO CLEARANCE GAS FIREPLACE SHALL BE INSTALLED PER MANUFACTURER SPECS. AND IN STRICT ACCORDANCE W/ LOCAL BUILDING CODES. MUST BE U.L. LISTED. (M1303/ G2427.2.1) 17'- 2 1/2" I I I 3'-6" 5'-0" KEYNOTE SCHELDULE KEY VALUE TEXT 10 DRYER: VENT TO OUTSIDE AND PER MANUFACTURER SPECICATIONS. DUCTS SHALL HAVE A SMOOTH INTERIOR FINISH AND CONSTRUCTED OF METAL. MAX. DUCT LENGTH PER TABLE M1502.4.4.1 OR M1502.4.4.2. (M1502) 11 TYPICAL EXTERIOR WALL: SIDING o/ INFILTRATION BARRIER o/ EXTERIOR SHEATHING PER STRUCTURAL PLANS 0/ 2X6 STUDS @ 16" O.C. w/ R-21 BATT INSULATION AND 1/2" MIN. GWB AT INSIDE FACE w/ P.V.A. PRIMER. 12 PILOTS, BURNERS, & SWITCHES TO BE 18" MIN. ABOVE FLOOR. ALL APPLIANCES TO BE U.L. RATED. DUCTS IN GARAGE AND THOSE PENETRATING THE WALLS OR CEILINGS SEPARATING THE GARAGE FROM THE DWELLING SHALL BE 26 GA. SHEET STEEL AND SHALL HAVE NO OPENINGS IN THE GARAGE. WATER HEATERS SHALL BE ANCHORED AGAINST MOVEMENT AND OVERTURNING IN ACCORDANCE WITH M1307.2. PROVIDE PRESSURE RELIEF LINE PLUMBED TO OUTSIDE. 13 FUEL FIRED APPLIANCES: WHERE THE VOLUME OF THE SPACE IN WHICH THE APPLIANCE IS LOCATED IS GREATER THAN 50 CU. FT. PER 1000 BTU/H THEN NO VENTILATION IS REQUIRED. IF LESS, PROVIDE VENTILATION IN ACCORDANCE WITH G2407.5. 14 ATTIC ACCESS: MIN. 22"X30" AND REQUIRED AT AREAS GREATER THAN 30 SQ. FT. AND VERTICAL HEIGHT OF 30" OR GREATER. (R807.1) SEE M1305.1.3 FOR ADDITIONAL REQUIREMENTS WHERE MECHANICAL EQUIPMENT IS LOCATED IN ATTIC. 17 CLOSET ROD w/ VINYL COATED WIRE SHELF 18 CLOSET SHELVING AND DRAWER ORGANIZERS PER BUILDER SPECS. 19 TEMP. GLASS DOOR 20 TEMP. GLASS WINDOW 21 TUB/SHOWER: ONE PIECE ACRYLIC OR FIBERGLASS WITH CURTAIN OR TEMP. GLASS DOOR PER OWNER SPECS. 22 ONE PIECE SHOWER WITH TEMP. GLASS SHOWER DOOR. 23 FIBERGLASS SHOWER PAN OR EQUIV. w/ TILE SURROUND AND TEMP. GLASS SHOWER DOOR. 24 FIBERGLASS TUB w/ TILE SURROUND AND CURTAIN OR TEMP. GLASS DOOR PER BUILDER SPECIFICATIONS. 27 1/2" GWB UNDER STAIRWAY IN ENCLOSED SPACES. 28 HYDROBLOK OR EQUIV. SHOWER PAN w/ TILE SURROUND. U Z N W O W Z O a E a �0 way LIL:1�a "� 0 J� U ��5) co CO 2 Z W N C W �! .m 0 °' W m o W a F E U I I C _ W z �46.10; E C E a a N Q o Z J 0. a~ a 2 a c c a I.`�' O J N d O O -@ N O Z' m 25 20,0 r 2 C E N O £O U a N UW H {p U a0 UEV -O N O 1.-0.0O•(-6` LU . ZaO N N N 2 O F E M N Lu N V 00 z Q Lu u Q Z 0 Z 0 cf) O o w LU oc L u C/) LL � w cn Z Z w W n C/) 0 06 0 0 I.L N O CN V a ti It 06 CUoo N rn N rn 0 U CU � o = E m _ cl mn a�i'j, c ° z _ CU o = a� L f0 3 UCU 2 L m � m •o a a� a i Q N 6 z PROJECT NO. 200101 REVISED 12/15/19 DESIGNED BY TL DRAWN BY TL & RM CHECKED BY TL SHEET NO. A5 PRINT DATE 9/4/2020 6:53:46 AM RESUB Feb 17 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SEE SHEET A4 FOR WIINDOW AND DOOR SCHEDULE 2ND FLOOR /L % 1/4" = 1'-0" north \F 14 13 Y1242'- 22'- 1 1/2" Q Q Q 19' -1 1/2" 6'-31/2" 3'-6" 3'-6" I I 1 I I 35 34 36 I I L - � I I K I I I I I I I I I I I I I I I I I I J - - � I I 19' -10 1/2" 2'-3" I I I G 1 HANDRAIL PROVIDE VENTILATION 3 Sim 1 MAKE UP AIR AT A3 LAUNDRY ROOM. I I I I I I I I I I I I I I I I I I I I I I I I H- - - - - - -- - - 17 14 ATTIC ACCESS 10 0 = — — — — — — — — — — 6' - 1 1 /2" 2' - T' _ - - - - 07 E M 11'- 5 1/2" D iNCLOSET - WASH'R DRY'R BROOM 80 CFM CLOSET OO S.D. 00 of 4' - 0„ 11 D29 D30 V.T.O. D28 6'-4" 3'-6" ti 3 1/2„ DUCTLESS D31 - S. C.O. MINI -SPLIT _' DUCTLESS S.D. 5'-6" 3'-0" MINI -SPLIT II D32 1 0 - REFRIG. BEROOM 4A.D.U. LIVING IRM. M N 5 (VAULTED SCISSOR TRUSS) 0 o SPACE (VAULTED SCISSOR TRUSS) ITCHEN TIMER CONTR L " CID ® M N BATH , c0 120 C 04 L ill °� 24 II V.T. . M WHOLE HOUSE _ FAN W TIM L ---- T----------- 11' 10" ch C CV C 14 I I I I 0' - 9 1/2" 13' - 1 1/2" 5'- 3 1/2'. Le 1 10'-6" 12' - 3 711T I. 1 42'-0" 1 1 1, 6„ - (TYP) 18' - 8" o 0 z 10 LL 33CD N ----- �, - ---- MASTER SUITE 10 _ � N N co , CV f0 NN 32 6'- 0„ D23 FIR E STANDING SO KING TUB D14 O® 20 TEMP. GL. 18 M-BATH DBL. 2x4 WALL WINDOWUU w/ INSULATION r` , — — — — — 80CFM 6'x4' SHOWER 4 TASK CTR 28 I T 4'-2" BENCH Q D26 5_9 M 80 CFM D25 ---� - x _4 I ��I - -� II- o' DRY'R 14 18 80 CFM I 9' 0" V. L------------------ ASH'R NJ PROVIDE VENTILATION — MAKE UP AIR AT LAUNDRY ROOM. 4'- 7 1 9'-11" 9'-3" KEYNOTE SCHELDULE KEY VALUE TEXT 12 M N LINEN CLOSET 7_ ;� � 08 16 I � I D8 0 - Oo MCD C.O. S.D. BED 7Ie� 2'-1" 4'-01/2" 18 0 N S.D. o D16 10'- 0 1/2" N c:) 0 O ' FAMILY RM. _ OPEN To 23 Zo coof BELOWN. zQ �U ATTIC ACCESS 22" x 30" 4' - 0" 4'- 6 1/2" 4'- 0' I I I I co DN 06 ---- -- 0 D22 I I I I I I I T 17 28 � I I I I I I I I I I I I I I 21 20 I I I ` 3'-51/2" 3'-6" 11 9' -1 1/2" 4'- 2 1/2" 3'- 5 1/2" 4'- 11 1/2" 49'-0" 6 5 I I 6'-91/2" 4'-4" 13'-3" 3'- 5 1/2" 1' - 9" 6'- 8 1/2" I I 180 CFM WHOLE HOUSE 2 Sim FAN w/ TIMER. INTERCONNECTED TO - MAIN FLOOR PWDR. 29 20 I I 27 1 12'-6" ° D15 I 08 TIMER BED 2 CONTROL L-- ---- D20 I BATH - 8'-0„ D24 � 6'- 6" S.D. I I Q2 � I 01 GARAGE DOOR: PROVIDE 1 3/8" SOLID CORE DOOR OR EQUIV. 20 MIN. RATED FIRE RATED DOOR BETWEEN HOUSE AND GARAGE. DOOR TO BE EQUIPPED WITH A SELF -CLOSING DEVICE. (R302.5.1) LANDINGS: THERE SHALL BE A FLOOR OR LANDING AT EACH SIDE OF EACH EXTERIOR DOOR. LANDING 02 OR FLOOR SHALL BE A MAX. 1.5" LOWER THAN THE TOP OF THE THRESHOLD; 7 3/4" IS PERMITTED AT EXTERIOR DOORS THAT DO NOT SWING OVER THE LANDING. MAX. LANDING SLOPE IS 1/4:12. (R311.3.1 & 311.3.2) 03 GARAGE WALL: SEPARATION FROM GARAGE AND RESIDENCE SHALL HAVE 1/2" GYPSUM BOARD APPLIED TO GARAGE SIDE. A 5/8" TYPE "X" GWB OR EQUIV. IS REQUIRED BETWEEN THE GARAGE AND HABITABLE SPACE ABOVE THE GARAGE. (R302.6 & TABLE 302.6) 04 COOKING APPLIANCES: HOUSHOLD COOKING APPLIANCES SHALL BE LISTED AND LABELED AND INSTALLED IN ACCORDANCE WITH MANUF. SPECS. RANGE HOOD SHALL HAVE LIGHT & 100 CFM MIN. EXHAUST FAN AND BE VENTED TO OUTSIDE WALL. EXAHUST HOOD SYSTEMS IN EXCESS OF 400 CFM SHALL BE PROVIDED WITH MAKE UP AIR IN THE AMOUNT EQUIV. TO THE EXHAUST RATE. (M1503) 05 CRAWLSPACE OPENING: MIN. 18"x24" THROUGH THE FLOOR OR MIN. 16"x24" THROUGH THE PERIMETER WALL. (R408.4) 06 GUARDS SHALL BE REQUIRED AT OPEN SIDED WALKING SURFACES, PORCHES, STAIRS, RAMPS, BALCONIES AND LANDINGS LOCATED MORE THAN 30" ABOVE THE FLOOR OR GRADE BELOW. GUARD SHALL NOT BE LESS THAN 36" IN HEIGHT. OPEN RAILS SHALL HAVE INTERMEDIATE RAILS SPACED SO THAT A 4" SPHERE CANNOT PASS THROUGH. (R312) 07 STAIR TREADS AND RISERS (R311.7): MAX. RISER HEIGHT SHALL BE 7 3/4". RISER SHALL BE MEASURED VERTICALLY BETWEEN LEADING EDGES OF THE ADJACENT TREADS. DIFFERENCE IN RISER HEIGHTS SHALL NOT EXCEED 3/8". THE MIN. TREAD DEPTH SHALL BE 10". DIFFERENCE IN TREAD DEPTH SHALL NOT BE GREATER THAN 3/8". FIREBLOCK STAIRS PER IRC 302.11. ALL STAIRS TO BE PROVIDED WITH A LIGHT AND SWITCH AT TOP AND BOTTOM OF STAIRS (R303.7). STAIR LANDINGS REQUIRED AT TOP AND BOTTOM (311.7.6) 08 EGRESS WINDOWS: OPENINGS ARE REQUIRED FOR ALL SLEEPING ROOMS AND BASEMENTS. BOTTOM OF CLEAR OPENING IS NOT TO EXCEED 44" ABOVE FLOOR. OPENABLE AREA IS 5.7 SQ. FT. NET CLEAR MIN. EXCEPT 5.0 SQ. FT. IS ALLOWED FOR AN OPENING WITHIN 44" OF FINISHED GRADE. (R310.1) 09 DIRECT VENT ZERO CLEARANCE GAS FIREPLACE SHALL BE INSTALLED PER MANUFACTURER SPECS. AND IN STRICT ACCORDANCE W/ LOCAL BUILDING CODES. MUST BE U.L. LISTED. (M1303/ G2427.2.1) 13'-6" KEYNOTE SCHELDULE KEY VALUE TEXT 10 DRYER: VENT TO OUTSIDE AND PER MANUFACTURER SPECICATIONS. DUCTS SHALL HAVE A SMOOTH INTERIOR FINISH AND CONSTRUCTED OF METAL. MAX. DUCT LENGTH PER TABLE M1502.4.4.1 OR M1502.4.4.2. (M1502) 11 TYPICAL EXTERIOR WALL: SIDING o/ INFILTRATION BARRIER o/ EXTERIOR SHEATHING PER STRUCTURAL PLANS o/ 2X6 STUDS @ 16" O.C. w/ R-21 BATT INSULATION AND 1/2" MIN. GWB AT INSIDE FACE w/ P.V.A. PRIMER. 12 PILOTS, BURNERS, & SWITCHES TO BE 18" MIN. ABOVE FLOOR. ALL APPLIANCES TO BE U.L. RATED. DUCTS IN GARAGE AND THOSE PENETRATING THE WALLS OR CEILINGS SEPARATING THE GARAGE FROM THE DWELLING SHALL BE 26 GA. SHEET STEEL AND SHALL HAVE NO OPENINGS IN THE GARAGE. WATER HEATERS SHALL BE ANCHORED AGAINST MOVEMENT AND OVERTURNING IN ACCORDANCE WITH M1307.2. PROVIDE PRESSURE RELIEF LINE PLUMBED TO OUTSIDE. 13 FUEL FIRED APPLIANCES: WHERE THE VOLUME OF THE SPACE IN WHICH THE APPLIANCE IS LOCATED IS GREATER THAN 50 CU. FT. PER 1000 BTU/H THEN NO VENTILATION IS REQUIRED. IF LESS, PROVIDE VENTILATION IN ACCORDANCE WITH G2407.5. 14 ATTIC ACCESS: MIN. 22"X30" AND REQUIRED AT AREAS GREATER THAN 30 SQ. FT. AND VERTICAL HEIGHT OF 30" OR GREATER. (R807.1) SEE M1305.1.3 FOR ADDITIONAL REQUIREMENTS WHERE MECHANICAL EQUIPMENT IS LOCATED IN ATTIC. 17 CLOSET ROD w/ VINYL COATED WIRE SHELF 18 CLOSET SHELVING AND DRAWER ORGANIZERS PER BUILDER SPECS. 19 TEMP. GLASS DOOR TEMP. GLASS WINDOW TUB/SHOWER: ONE PIECE ACRYLIC OR FIBERGLASS WITH CURTAIN OR TEMP. GLASS DOOR PER 20 21 OWNER SPECS. 22 ONE PIECE SHOWER WITH TEMP. GLASS SHOWER DOOR. 23 FIBERGLASS SHOWER PAN OR EQUIV. w/ TILE SURROUND AND TEMP. GLASS SHOWER DOOR. 24 FIBERGLASS TUB w/ TILE SURROUND AND CURTAIN OR TEMP. GLASS DOOR PER BUILDER SPECIFCATIONS. 27 1/2" GWB UNDER STAIRWAY IN ENCLOSED SPACES. 28 HYDROBLOK OR EQUIV. SHOWER PAN w/ TILE SURROUND. U Z N 00 00 W z QE a �0 wa•�, UJ� M CO sO Z W N C W o W m o W a 2 E U w ffag TliJlllillilli-flll7ll' �'� c Z y .0. C a y d :0 N C CYO C O O N E oZ�o�o�Ot'=ammv°�ioacima og c wam c�:: otH T�LU E m 20an�-� ° O J y C 0 0— @ t" O N U 0 o. 2 0. .t.. � C N O L o Q ' ._ 9 10 8.2 C E N O W� U£ O U C U EO p C0.C ?� N N U UJ J— y U �O U n ..-0 ib 0 O H c m m 0 Z ao � aEi maoIS E d Lu N V00 C) Z Q Lu lv Q � Z o z O cf) O o w LU oc W co — w U) Z Z w W W 0 o N c) N V a 64 It 00 2 CU o 0 N M 0 N 0) 0 N rn E 0 o E f0 U 2 � � a a)c C C — °_ ° mn o U (D 'c N L -0 0 a).� U Y ._ L a) 0- 55 `- E �5 .c �a) �� E 1 *5: � a) C im ,� E 2 c X Q 6 z M It Ln PROJECT NO. 200101 REVISED 12/15/19 DESIGNED BY TL DRAWN BY TL & RM CHECKED BY TL SHEET NO. PRINT DATE 9/4/2020 6:54:28 AM RESUB Feb 17 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 1" AIR SPACE w/ CARDBOARD BAFFLE. EXTEND 24" ABOVE INSULATION VENT BLOCKS w/ (3) 2" dia. WIRE SCREENED VENT HOLES @ EA. BLOCK CONT. ALUM. GUTTER ON FASCIA BOARD PER ELEVATIONS ROOFING PER ELEVATIONS o/ 30 # FELT OVER %s"APA RATED 24/16 SHEATHING ON MANUF. TRUSSES PER PLAN 2" CEILING G.W.B. OVERHANG I TOP PLATES & TRUSS TIE PER PER PLAN STRUCTURAL I O I 2" GYPSUM WALL BOARD w/APPROVED P.V.A. VAPOR RETARDER R-21 BATT INSULATION R-49 BATT OR BLOWN INSUL. 0 io EXTERIOR FINISH PER ELEVATION o/ 15# BUILDING PAPER OR APPROVED AIR INFILTRATION BARRIER o/ SHEATHING PER STRUCTURALPLANS. R-21 BATT INSULATION AT RIM 2x_ BASE PLATE P.T. 2x10 MUD SILL RIPPED TO 8" w/ ANCHOR BOLTS PER SHEAR WALL SCHEDULE. 4" TIGHTLINE DRAIN WHERE REQ'D z_ 4" PERF. FT'G DRAIN. WRAP IN FILTER FABRIC C9 w/ GRAVEL OVER. ujQ a uj J d a v hk a �/.IX /\/i PER PLAN CAULKING/ SEALANT BEAD AT FLOOR PERIMETER SUB FLOORING & FLOOR JOISTS PER STRUCTURAL FLOOR TRUSSES PER PLAN %2" GYPSUM CEILING BOARD 2" GYPSUM WALL BOARD w/APPROVED P.V.A. VAPOR RETARDER R-21 BATT INSULATION CAULKING/ SEALANT BEAD AT FLOOR PERIMETER SUB FLOORING & FLOOR JOISTS PER STRUCTURAL R-30 BATT INSULATION HANGER PER SCHEDULE FOUNDATION WALL SIZE AND REINFORCING PER STRUCTURAL FOOTING SIZE AND REINFORCING PER STRUCTURAL TYPICAL TWO STORY ASSEMBLY SCALE: 3/4" = V-0" 4 d a O 0()° �O o 09 8 ° a 0&1 00C)o a 4" CONC SLAB o/ COMPACTED GRANULAR FILL Z a i' LLJ J d ® (1 a °__-- �- a SEE TYP. ASSEMBLY SEE TYP. ASSEMBLY P.T. 2x6 MUD SILL w/ ANCHOR BOLTS PER SHEAR WALL SCHEDULE. FOUNDATION WALL SIZE AND REINFORCING PER PLAN FOOTING SIZE AND REINFORCING PER PLAN. PER PLAN RECESSED JOISTS @ GARAGE SCALE: 3/4" = V-0" 2ND FLO N FL( IN FL( H) CG i BUILDING AT SCALE: 1/4" = 1'-0" SEE TYP. ASSEMBLY P.T. 2x6 BASE PLATE w/ ANCHOR BOLTS PER SHEAR WALL SCHEDULE) d x 44 x x d x d 4 0O 8 00008 a 8 0 °oo 4" CONIC. SLAB o/ 2" RIGID INSUL. w/ THERMALBRAKE o/ COMPACTED GRANULAR FILL J SECTION OEL)2ND FLOOR 2ND FLOOR M N MAIN FLOG MAIN FLOOI 2\\, BUILDING SECTION SCALE: 1/4" = 1'-0" A7) 4" CONC SLAB OVER COMPACTED GRANULAR FILL a d � d a =7 00 - 02 o� o� oa oo a 1 a° FOUNDATION WALL SIZE AND REINFORCING PER PLAN FOOTING SIZE AND REINFORCING PER PLAN. FOUNDATION @ GARAGE / LIVING SCALE: 3/4" = 1'-0" "L" FLASHING PER ROOFING MANUF. ROOFING PER ELEVATIONS OVER 30# FELT OVER APA 24/16 RATED OSB SHEATHING MANUF.MONO TRUSSES OR STICK FRAMING PER ROOF PLAN BEAM PER FRAMING PLAN. HANGERS AS PER SCHEDULE \' TRUSS TO FLOOR SYSTEM SCALE: 3/4" = 1'-0" L TYP. ASSEMBLY FIRE BLOCKING BEAM INTO UP WALL IF NEEDED ADD BLOCKING IF NEEDED R-30 BATT INSUL. FOR HEATED AREA ABOVE FLOOR JOIST PER PLAN CEILING FRAMING PER PLAN SIDING INSTALLED PER MANUF. SPECIFICATION EXTERIOR TRIM PER PLAN 4"x_ "L" METAL FLASHING w/ DRIP EDGE INSTALLED UNDER BARRIER �— DBL. 2x6 TOP PLATES 2" RIGID R-10 INSULATION INSTALLED IN CAVITY BETWEEN HEADER & INTERIOR G.W.B. HEADER PER PLAN SEALANT I WINDOW FINISH AND TRIMS I PER OWNER SPECS. I HEADER INSULATION DETAIL SCALE: 1 1/2" = 1'-0" 1%" dia. MIN., 2" dia. MAX. HANDRAIL w/ RETURNS TO WALLS U GLE OJAT- �NjIR EASER O ALL OT ALLOW of A 6' PH E TO PASS Q X THR UGH. _ 4 p z N � BETTER AT TREADS M O z z 10" MIN. ' MIN � � m RUN Q 1 IMAX. o ZV XQ � w v L0 M i i � I 2" MIN. PLWD RISERS NOTE: MIN. T-0" CLEARANCE WIDTH REQ IRED FOR STAIRS INTERIOR STAIRS SCALE: 3/4" = V-0" MAIN FLOOR PLATE BALUSTER TO CONFORM TO IRC w/ SPACING SUCH THAT A 4" SPHERE SHALL NOT PASS THROUGH %4" T&G APA 48/24 RATED SHEATHING GLUED & NAILED TO FLOOR JOISTS DBL. JOIST U.NO. ON PLANS V --Ill JOISTS PER PLAN HANGER PER SCHEDULE SIMPSON "A35" EA. SIDE AT STRINGERS STRINGERS PER PLANS (1) LAYER 2" GWB UNDER STRINGERS FIRE BLOCKING BETWEEN STUD BAYS AT WALLS IN CONTACT w/ STRINGER. U z � N co O co Q > U im-Y 2 o w�� "�� O J V U M.o z 00o W N '- W 0 Q) W m 0 W H p Z� 0 O t` T O _ d p a O m C ib O O O O 0 O J y a N a O. t0 (6 O N C y } Z QL.. @ to (Oi N N OJ N y E. d W OLu �W Uw0 n"a3-oOJ o-a� m0 5� o ?� J Q O F O uj co N V 00 z Q UJ (C6 � Q Q Z OOz O G O Q cl) U w UJ uj (� U. w z NW z L.f_ Z Lu � Q N 0 N � Q V 00 w 0 c 0 :r a I- 0 w m 0 O z PROJECT NO. 200101 TL DESIGNED BY DRAWN BY TL & RM CHECKED BY RR SHEET: A7 PRINT DATE 9/3/2020 ' Feb 17 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT GENERAL NOTES All design and construction shall conform to the requirements of the International Building Code 2015 Edition. Contractor shall verify all levels, dimensions and existing conditions in field before proceeding with any construction or demolition. Contractor shall notify the Architect of any discrepancies or field changes Contractor shall be responsible for all safety precautions and the methods, techniques, sequences or procedures required to perform the work. Contractor shall provide adequate shoring and bracing of all structural members, existing construction and soil excavations as required, in a manner suitable to the work sequence. Temporary shoring and bracing shall not be removed until all final connections have been completed in accordance with the drawings and materials have achieved design strength. Foundations walls greater than 4 feet shall not be backfilled until the floor framing and all connections to the floor framing per these details are complete. CHANGES: No changes to these structural drawings are permitted without written consent of the Engineer. Changes will be billed to the client, owner or contractor at the Engineer's hourly rate. SUBMITTALS: Shop drawings shall be submitted to the Architect prior to any fabrication or construction for all the following: Structural steel, steel canopies, glued -laminated members and pre -manufactured wood members. Design drawings and calculations, for pre -manufactured wood trusses and joists shall bear the seal and signature of the Washington State Registered Professional Engineer who is responsible for the design, and shall be submitted to the Architect and Building official for review prior to fabrication. DESIGN LOADS LIVE LOADS: Live loads are determined in accordance with ASCE Ch. 7 L = 40 PSF (Residential) SNOW LOADS: Snow loads are determined in accordance with ASCE Ch. 7 with the following Factors: Ground Snow Load Pg = 20 psf Ct = 1.0 Ce = 1.0 Roof Snow Load Ps = 25 psf Is = 1.0 WIND LOADS: Wind loads are based on ASCE 7-10 Ch. 28 (Envelope Procedure) with the following factors: Exposure Category = B Iw = 1.0 Velocity (3 sec) =110 mph (ult) Kzt = 1.0 Design wind pressured for determining forces on components and cladding are determined in accordance with ASCE 7-10 Chapter 30. SEISMIC LOADS: Seismic loads are based on the Equivalent Lateral Force Procedure in ASCE 7-10 Section 12.8 with the following factors: Risk Category = II Ss = 1.28 Site Class = D S1 = 0.501 Design Category = D SIDS = 0.853 R = 6.5 (wood shear wall) SD1 = 0.501 Ie = 1.0 Cs = 0.131 (ult.) FOUNDATIONS Concrete foundations shall bear on stiff, competent, undisturbed native soil. Prior to construction, the contractor shall obtain confirmation from the Building Official that the native soil at this project is adequate to support the following bearing pressure: Allowable bearing pressure used for structural design = 2000 psf (assumed) Where footings must bear on structural fill due to inadequate soil conditions, the fill shall be mixed and compacted in accordance with specifications provided by a Geotechnical Engineer licensed in the State of Washington. Bottom of footing elevation shall be located at minimum frost depth 18" below top of finished grade unless required otherwise by the Building Official. The contractor shall confirm the minimum frost depth with the Building Official prior to excavation. CONCRETE Concrete work shall comply, in general, with ACI 301 (latest edition) "Specifications for Structural Concrete for Buildings." CONCRETE MIXES: Concrete mixes shall conform ACI 318 Ch. 5. Minimum concrete strength f'c at 28 days shall be as follows: Slab -on -grade, Curbs and Pads - 2000 psi Footings - 2500 psi Walls, Stems - 3000 psi (2500 psi used for structural design) Water/cement ratio shall be measured by weight and shall be based on the total cementitious material. Water/cement ratio shall be determined by the supplier based on strength requirements and shall not exceed 0.55. Water -reducing admixtures may be incorporated in concrete mix designs but shall conform to ASTM C 464, and be used in accordance with the manufacturer's recommendations. CaCI and other water-soluable chloride admixtures shall not be used. REINFORCING STEEL: All reinforcing shall be deformed bar (rebar) with bar diameters specified in these drawings and properties below: All reinforcing unless noted otherwise - ASTM A615, Grade 60 #3 stirrups and ties - ASTM A615, Grade 40 Welded rebar - ASTM A706, Grade 60 Galvanized Welded Wire Fabric - ASTM A165 Reinforcing steel shall be detailed in accordance with ACI 315 "Manual of Standard Practice for Detailing Reinforced Concrete Structures." Reinforcing steel shall be lapped as noted on the drawings. Where lap length is not shown, reinforcing bars shall be lapped as follows: #5 and smaller - 48 bar diameters #6 and larger - 60 bar diameters Minimum concrete cover over reinforcing shall be as follows: Nonstructural Slab -on -grade - Mid -Depth Wall Bars: interior face - 3/4" exposed to earth/weather - 1-1/2" (#5 and smaller) 2" (#6 and larger) Footings: Bottom Bars - 3" (cast against earth) Top Bars - 1-1/2" Side Bars - 2" Provide supports as required for proper alignment and concrete cover around the reinforcement. Consult the CRSI Manual of Standard Practice MSP-1 for specific information. RECOMMENDED INSPECTIONS The following recommended minimum items shall be inspected by a qualified individual provided by the Building Official: -Footings bear on competent native soil per the "Foundations" section above -Footing reinforcement -Shear wall sill plate anchors and washers per schedule -Shear wall nailing and shear clips per schedule -Shear wall hold-downs TYPICAL DETAILS n addition to the details and schedules on the framing plans, those noted as "Typical" shall be sed throughout the structure as applicable. STRUCTURAL NOTES WOOD SAWN LUMBER: Structural sawn lumber shall be kiln dried and be of the species and grade noted below or better: Use Grade Fb(psi) Wall Studs Stud 675 Plates & Planks Hem Fir #2 850 Joists & Rafters Hem Fir #2 850 4x Beams Douglas Fir -Larch #2 900 6x Beams Douglas Fir -Larch #2 875 Posts Douglas Fir -Larch #2 750 2x4 T&G Decking Douglas Fir -Larch Select 1750 All lumber and plywood in contact with concrete, stucco, masonry or other cementitious materials shall be treated with an E.P.A. acceptable wood preservative, such as Alkaline -Copper -Quaternary "ACQ" or Copper Azole "CBA" type A and B. All wood connectors shall be manufactured by Simpson Strong Tie Company (or approved equal), and of the size and type shown on the drawings. All wood connectors in contact with preservative -treated wood shall be Triple Zinc G-185 galvanized (1.85 oz/sq ft coating). MINIMUM WOOD NAILING REQUIREMENTS: Unless otherwise noted on the drawings, typical wood framing shall be fastened as follows. See IBC Table 2304.10.1 for fastener alternatives not shown. Location Min. Nail Quantity/Spacing Type* Beams (built up 2x's) 3" x 0.131" 24" o.c. T&B* FN EF* staggered Blocking -to joists, rafters, trusses 3" x 0.131" 2 each end TN or studs -to top plates 3" x 0.131" 3 TN Bottom plate -to joist, rim joist 3" x 0.131" 12" o.c. FN or blocking -to studs 3" x 0.131" 3 EN Header (built up 2x's) 16d box 12" o.c. T&B FN Header -to studs 3" x 0.131" 4 TN Joist -to supports 3" x 0.131" 3 TN -to rim joist 3" x 0.131" 4 EN Rafter -to supports 3" x 0.131" 4 TN, EN Rim Joist -to sill or blocking 3" x 0.131" 6" o.c. TN Stud -to Stud 3" x 0.131" 12" o.c. FN -to top/bottom plate 3" x 0.131" 4 TN Top plate -to top plate 3" x 0.131" 12" o.c. FN -to studs 3" x 0.131" 3 EN -laps at corners and 3" x 0.131" 3 FN intersections Truss to top plate 3" x 0.131" 4 TN *EN = end nail, FN = face nail, TN = toe nail, EF = "each face", T&B = "top and bottom" RATED SHEATHING: Wood structural panels shall bear the APA trademark of the American Plywood Association. Sheathing shall be as follows: Shear Wall Shtg 7/16" 32/16 C-D INT APA with Exterior Glue (CDX) Roof Shtg 15/32" 32/16 C-D INT APA with Exterior Glue (CDX) Sub Floor Shtg 3/4" 48/24 T&G C-D INT APA with Exterior Glue Sheathing shall be orientated over the supports as shown on the drawings. Shear wall sheathing shall be blocked at all panel edges as shown in the shear wall schedule. GLUED LAMINATED MEMBERS: Glued Laminated members shall each bear an AITC identification mark and be accompanied by an AITC certificate of conformance. One coat of end sealer shall be applied immediately after trimming either shop or field. Members shall be Visual Graded Western Species Inductrual, Architectural or Premium grade with strength as follows: Symbol Species Fb E GLIB24F-V4 DF/DF 2400/1850 psi 1,800,000 psi GLIB 24F-V8 DF/DF 2400/2400 psi 1,800,000 psi ENGINEERED COMPOSITE LUMBER: Engineered Composite Lumber shall be manufactured by Trus-Joist, Boise Cascade or approved equal and shall have the following minimum strength (based on 12" member depth): Symbol Fb E PSL 2900 psi 2,000,000 psi LVL 2600 psi 2,000,000 psi LSL 1700 psi 1,300,000 psi Versa -Lam (1%4-2%") 2800 psi 2,000,000 psi VersalLam (3%" & wider) 3100 psi 2,000,000 psi PREMANUFACTURED OPEN WEB WOOD TRUSSES: Trusses shall be design by a Structural Engineer licensed in the State of Washington, who is regularly engaged in the design of plate -connected wood trusses. Truss design shall be accordance with IBC Section 2303.4. Trusses shall be design for the following dead loads: top chord bottom chord total roof trusses 10 psf 5 psf 15 psf In addition to dead loads, the design shall include the live, wind, snow loads as identified in the "Design Loads" section of these drawings, and the snow drift, sliding and unbalanced loads per ASCE7 Chapter 7. The truss design shall include concentrated and axial loads shown on framing plans and hanger schedules in these drawings. Roof trusses shall be designed for wind net uplift of 10 psf unless otherwise noted on the drawings. Trusses shall be fabricated by a manufacturer who is a member of the Truss Plate Institute. Trusses shall be supplied with the proper hangers, end connections, bridging, bracing to provide lateral stability of all truss members, and tie -down connections to beams and tops of walls. Trusses shall be supplied with tapered hardwood shimming so that every chord bears on the full width of every support, without notching the truss members. The truss manufacturer is responsible for ensuring the bearing seat does not exceed the sill plate capacity of the supporting element. PREMANUFACTURED WOOD I -JOIST: Shall be fabricated by Truss -Joist or Boise Cascade. Alternative manufactures must be approved by the Architect or Engineer. Joists shall be installed according to the manufactures instructions including blocking, web stiffeners, bridging, etc. Fasten joists to supports as recommended by the joist and hanger manufacturer. Provide temporary bracing as recommended by the manufacturer to hold joists in place until permanently secured, Cut openings in joist webs only as allowed by the manufacturer. SON CS16 WITH (20) "0 DBL. TOP PLATE D AT EACH SIDE. 0 AS NEEDED. -,,r PER PLAN NOTES: 1. USE THIS DETAIL AT ALL LOCATIONS WHERE BEAM WIDTH EXCEEDS 3%2" AND/OR BEAM BOTTOM BEARING IS BELOW DOUBLE TOP PLATES. 2. EXTEND BEAMS FOR 5-1/2" BEARING ON 2x6 WALLS, 3-1/2" BEARING ON 2x4 WALLS. TYPICAL PLATE STRAP AT BEAMS X Q 00 v MAN WOOD FRAMING PER PLAN VARIES. SEE 15/S2 FOR ALL CONNECTIONS PT SILL PLATE w/ ANCHOR BOLTS AND WASHERS PER SHEAR WALL SCHEDULE. MINIMUM ANCHOR BOLT EMBEDMENT = 7". #4 HORIZ. AT 18" o.c. AND (2) AT TOP OF WALL #4 VERT. DOWELS AT 18" o.c. ALTERNATE HOOK AT BOTTOM FOOTING PER PLAN SEE 3/S1 FOR ALTERNATE AT HUNG JOISTS TYPICAL CONCRETE FOUNDATION 1 SINGLE REINFORCING NOTES: 1. VERTICAL REINFORCING NOT SHOWN FOR CLARITY 2. SEE STRUCTURAL NOTES FOR CLEAR COVER 24" #4 x 24" MATCH HORIZ REINF. 24" 44 x 24" MATCH HORIZ 1EINF. #4 x 24" MATCH HORIZ REINF. DOUBLE REINFORCING TYPICAL CONCRETE WALL AND FOOTING CORNER 1 4 DIAPHRAGM NAILING SCHEDULE NAIL SPACING NAIL SPACING AT AT BOUNDARIES INTERMEDIATE NAIL SPACING BLKG SIZE OF AND "OTHER" FRAMING AT BLOCKED LOCATION SHEATHING REQD NAIL PANEL EDGES MEMBERS PANEL JOINTS ROOF SEE STRUCT NOTES NO 10d 6" OC 12" OC 6" OC SUB-FLR NO 10d & GLUE 6" OC 12" OC 6" OC DIAPHRAGM NOTES 1. ALL DIAPHRAGM SHEATHING IS TO BE STAGGERED IN THE DIRECTION OF THE PLYWOOD SPAN PER DIAPHRAGM DETAIL 2. PROVIDE BOUNDARY NAILING CONTINUOUS AROUND THE ENTIRE PERIMETER OF THE DIAPHRAGM 3. NAILS SHALL BE COMMON OR GALVANIZED BOX 4. ALL FRAMING MEMBERS SHALL BE 2x MINIMUM NOMINAL WIDTH BLOCKED DIAPHRAGM TYPICAL CONTINUOUS WHERE INDICATED PANELJOINT � � fl H 11 9: IJ t1 1J BOUNDARY 'I 11 11 11 11: Id fl 1J it 11 NAILING :t 11 11 li li H TOP PLATE IJ 3:IJ 11 11 II IJ BLOCKED CONTINUOUS PANELJOINT U IJ II "OTHER" PANEL 11 FI 1� EDGE NAILING INTERMEDIATE JOIST/TRUSS NAILING DIAPHRAGM DETAIL TYPICAL DIAPHRAGM NAILING 1 7 II II I I ROOF TRUSSES/ I I� RAFTERS BELOW I L II �� I I 2x6 BLOCK BETWEEN ROOF �~ _ TRUSSES BELOW W/ (2) 16d I I EA END I I I I I I i 2x6 PLATE W/ I 1 (2) 16d INTO EA ROOF I I i TRUSS BELOW I/I/ I I I I I I 2x4 RAFTEFjS Pa 24"o.c. POST DOV�NITO ROOF I I TRUSS BELOV� AT 24" o.c. I I I I i I I � II TYPICAL ROOF OVERFRAMING I 10 SHEAR WALL PER PLAN PT SILL PLATE w/ ANCHOR BOLTS AND WASHERS PER SHEAR WALL PLAN AND SCHEDULE. EMBED = 7" MIN. X Qz bo W PERFORATED FTG. DRAIN CO N'T. CONCRETE SLAB ON GRADE PER PLAN. ELEVATION MAY VARY. SEE ARCHITECTURAL FOR INSULATION REQUIREMENTS WHERE APPLICABLE. #4 HORIZ. AT 18" o.c. AND (2) AT TOP OF WALL #4 VERT. DOWELS AT 18" o.c. ALTERNATE HOOK AT BOTTOM FOOTING PER PLAN TYPICAL CONCRETE FOUNDATION AT SLAB 1 2 LAP JOIST OVER BEARING MIN. 6" AND NAIL WITH (3) 10d FLOOR JOISTS PER PLAN 2x CONT. BLOCKING OVER BEAM POST PER PLAN WITH CAP (OR GUSSET PLATE) AND BASE PER POST SCHEDULE VAPOR BARRIER PER ARCHITECTURAL TOP PL ADD( A7 "' v FLOOR SHEATHING PER STRUCTURAL NOTES INSULATION PER ARCHITECTURAL BEAM PER PLAN #30 FELT BETWEEN POST AND CONCRETE (NOT REQUIRED AT PRESSURE TREATED POSTS) FOOTING WITH REINFORCING PER PLAN FINISHED GRADE TYPICAL CRAWL SPACE FRAMING I rj 10% 1 01 AI A 11 C CA/ U C-C NOTES: SEE STRUCTURAL NOTES FOR TYPICAL TOP PLATE NAILING NOT SHOWN TYPICAL TOP PLATE SPLICE 1 $ THICKENED SLAB FOOTING AT POST I 1 1 SHEAR WALL PER PLAN SOLE PLATE CONNECTION PER SHEAR WALL SCHEDULE EDGE NAILING TO SOLE PLATE SLAB ON GRADE PER PLAN FLOOR BOUNDARY NAILING PER DIAPHRAGM SCHEDULE 2x PT SILL PLATE RIPPED TO MATCH CONC. WALL WIDTH w/ BOLTS PER SHEAR WALL SCHEDULE FLOOR JOISTS PER PLAN, JOIST BLOCKING AT 48" o.c. WHERE JOISTS ARE PARALLEL TO WALL. HANGER PER PLAN PROVIDE VAPOR BARRIER BETWEEN JOIST AND CONCRETE WALL FOUNDATION PER PLAN. SEE DETAIL 1/S1 UNLESS NOTED OTHERWISE HUNG JOISTS AT TYPICAL STEM WALL I $ (3) #4 VERT. DOWELS FOOTING PER PLAN TYPICAL EXTERIOR ISOLATED FOOTING 16 CRIPPLE STUDS AT 16" O.C. WHERE APPLICABLE TOP PLATES NAIL STUD TO HEADER W/ (8) 16d STUDS) PER PLAN FULL HEIGHT TO TOP PLATES TRIM STUDS (TRIMMERS) PER POST PLAN POST BETWEEN JOISTS SOLID BLKG MATCH WIDTH OF BEAM/GIRDER qF ALA 6d 6d )R. PI C( 'LA rIN TYPICAL HEADER DETAIL 1 9 VG POST AT JOISTS SECTION 12 Ross Engineering Design Inc JOB # 20022 ryan.ross@rossengineer.com 4/7 2020 a� P�A f, J B# 0 2 0 46411 ONA ELECTRONIC COPY ORIGINAL ON FILE AT ROSS ENGINEERING N Uw Z��o�_ y m c0 F°° o , EmmuoZoNwco_ma ` au o c °L_' U a o 0 m 6°« m o E Z N° s m o. E N "5C ti c 0 WLL io 03 mo m=3cdw w F p- N ' -o � � °- 0 1m o F -Oa d o t E m 6,> E m J Q O F O UJ N Z00 LU Q v! Z z O 2 UJ O o u w UU () U. w Z LLJ Z Z W U) 06 0 z N 0 N Q � 00 m 0 g �L N m 0 6 Z FILE/ NO. DESIGNED BY RR DRAWN BY RR CHECKED BY RR SHEET: S1 PRINT DATE BE'SUB FULL HEIGHT SHEAR WALL PER PLAN ROOF BOUNDARY NAILING 2x BLOCKING WITH 16d AT 6" o.c. ROOF BOUNDARY NAILING CONT 2x SHAPED BLOCKING SHEAR CLIPS PER SHEAR WALL SCHED. EDGE NAILING SHEAR WALL PER PLAN SHEAR WALL PER PLAN FULL HEIGHT OF WALL ROOF BOUNDARY NAILING 16d AT 6" o.c. 2x BLKG. AT 48" o.c. I I 2x LEDGER OR I TRUSS TOP CHORD I EDGE NAILING I I I I IX TRUSSES PER PLAN 2x CC WITI- ROOF TRU SHEAR WALI ROOF CONT. EDGE NAILING H1 CLIP EACH TRUSS BEAM PER PLAN HANGERS PER PLAN 2x BLOCKING SOLE PLATE NAIL/SCREW FLOOR BOUNDARY NAILING JOISTS PER PLAN, BLOCKING m AT 48" o.c. AT 1 g JOISTS PARALLEL 1 TO BEAM SECTION 1 2x CONT. BLOCKING SOLE PLATE NAIL/SCREW FLOOR BOUNDARY NAILING 2x BLOCKING w/ 16d AT 6" o.c. JOISTS PER PLAN, BLOCKING AT 48" o.c. AT JOISTS PARALLEL TO BEAM. HANGERS PER PLAN AT PERPENDICULAR JOISTS BEAM PER PLAN SECTION 6 SEE 15/S2 FOR SHEAR WALL CONNECTIONS NOT SHOWN NG FLOOR SHEATHING PER STRUCTURAL NOTES TYP FLOOR JOISTS PER PLAN SECTION 1 1 TRUSS TO BEAM 116 HOLD-DOWN ANCHOR SCHEDULE HOLD-DOWN ANCHOR IN CONC. STEM WALL FLOOR TO FLOOR ANCHOR' HDU4 SB %$ x 24 %$" DIA. HDU5 SB %$ x 24 %$" DIA. HDU8 SB / x 24 %g" DIA. HDUll SB 1 x 30 1" DIA. HDU14 SB 1 x 30 1" DIA. ANCHOR TYPE D-DOWN PER SQUASH BLKC kTCH POST SIZ ANCHOR PER SCHEDULE \DD #4 x 48" \T EACH ANCH SHEAR WALL PER PLAN FULL HEIGHT OF WALL 10d AT 4" o.c. SHEAR WALL PER ROOFS 2x E ROOF BOUNDARY NAILING TRUSS BLOCKING DESIGN FOR 300 PLF SHEAR LRFD SHEAR WALL SHEAR CLIPS EDGE NAILING SHEAR WALL PER PLAN ROO' " " -r-"- "-" ", ROOF C( 16 NOTES: 1. F1554 THREADED ROD SECTION 1 2 TYPICAL SHEAR WALL SCHEDULE NUMBER OF SHEAR WALL STUD/BLKG. SILL PLATE / SOLE PLATE FRAMING ANCHOR TO NAIL/SCREW 1, 2 SHEATHED EDGE 3 AT ADJOINING $ 9 SYMBOL SHEATHING SIDES NAILING PANEL EDGES s SIZE CONCRETE 7 TO RIM JOIST SHEAR CLIPS SWl(P) 1 8d @ 6" OC 2x 2x 5/8" DIA. AB 3"x.131" NAIL 3"x.131" TOENAIL @ 48" OC @ 6" OC @ 6" OC SW2(P) 1 8d @ 6" OC 2x 2x 5/8" DIA. AB 16d BOX NAIL LTP4 @ 24" OC SEE @ 48" OC @ 6' OC SW3(P) STRUCT 1 8d @ 4" OC 2x 2x 5/8" DIA. AB 16d BOX NAIL LTP4 @ 18" OC NOTES @ 32" OC @ 4' OC SW4(P) 1 8d @ 3" OC 4 3x e 2x 5/8" DIA. AB 16d BOX NAIL LTP4 @ 14" OC @ 24" OC @ 3' OC SW5(P) 1 8d @ 2" OC4 3x 2x 5/8" DIA. AB 16d BOX NAIL LTP4 @ 10" OC @ 18" OC @ 2.5" OC s'�-yD I� D EAR WALL O�� STyD `HOLD-DOWN ID SHEAR CLIPS PER SHEAR SHEAR WALL KEY WALL SCHEDULE WHERE APPLICABLE TYP. SQUASH BLOCKS IN RIM JOISTS AT ALL POSTS AND IIIII III III III III III I:I HOLD-DOWNS, ALL LEVELS. 11 SEE TYPICAL POST BLKG. _ —I _ _ _ DETAIL TYP. I)- — T i — — — iT 1.1 1.1 I I I•I I•I I: II I II EI ANCHOR TYPE HOLD-DOWN W/ ANCHOR ROD PER I I I I r I' SHEAR WALL SCHEDULE NOTES 1. SHEAR WALLS NOTED AS "SW_" INDICATE "SEGMENTAL SHEAR WALL" PER DETAIL (RIGHT) 2. SHEAR WALLS NOTED AS "SW_P" INDICATE "PERFORATED SHEAR WALL" PER DETAIL (RIGHT). APPLY ALL SHEATHING, NAILING AND FRAMING REQUIREMENTS PER SCHEDULE TO THE FULL LENGTH OF SHEAR WALL INCLUDING AREAS ABOVE HOLD-DOWN SCHEDULE TYP. 8d AT 12" o.c. NAILING AT ALL INTERMEDIATE SUPPORTS I I I I I I I II I I I I I I I I I I I I I I AND BELOW OPENINGS. PANEL EDGE NAILING TYP. 3. NAILS SHALL BE COMMON OR GALVANIZED BOX UNLESS NOTED OTHERWISE. 4. WHERE NAIL SPACING IS LESS THAN 4"oc, STAGGER NAILS Y2". SILL/SOLE PLATE W/ 5. ALIGN ALL VERTICAL ADJOINING PANEL EDGES WITH STUD PER SCHEDULE. PROVIDE BLOCKING PER SCHEDULE AT ALL ANCHORS PER SCHED. TYP. HORIZONTAL ADJOINING PANEL EDGES. 6. AT SW4 ONLY, 3x FRAMING MAY BE SUBSTITUTED WITH (2)2x NAILED TOGETHER W/ 3"0.131" NAILS @ 3" ox EACH FACE. ANCHOR TYPE HOLD-DOWN 7. AT SW1 PROVIDE STANDARD CUT WASHERS AT ALL SILL BOLTS. AT SW2 AND HIGHER PROVIDE 3"x3"x.223" STEEL PLATE PER PLAN WHERE WASHERS. LOCATE EDGE OF WASHER WITHIN %" OF EDGE OF SHEATHED SIDE OF SILL PLATE. HOLE IN WASHER MAY BE APPLICABLE. SEE SCHEDULE DIAGONALLY SLOTTED 1.75" MAX. FOR ANCHOR ROD TYP. 8. ENSURE ONE CLIP EACH END OF SHEAR WALL AT EACH REQUIRED FACE OF SHEATHING. 9. SHEAR CLIPS ARE REQUIRED ONLY AS INDICATED IN THE SECTIONS. SEGMENTAL SHEAR WALL 10. SEE DETAIL (BOTTOM FAR RIGHT) FOR TYPICAL TOENAIL FLOOR JOISTS PER PLAN SECTION 1 7 "w-Rilollbl � SOLE PLATE NAIL/SCREW FLOOR BOUNDARY NAILING AM PER PLAN ER PLAN SECTION 112 RAFTER TO BEAM 117 ROOF SHEATHING PER STRUCTURAL NOTES ROOF BOUNDARY NAILING 2x BLOCKING PANELS PROVIDED BY TRUSS MANUFACTURER SHEAR WALL SHEAR CLIPS EDGE NAILING SHEAR WALL PER PLAN ROOF TRUSSES PER PLAN H1 CLIP EACH TRUSS SHEAR WALL AT RAISED TRUSS HEEL 1 $ SOLE PLATE NAIL/SCREW EDGE NAILING EDGE NAILING TO RIM JOIST FLOOR BOUNDARY NAILING EXTEND LOWER SHEAR WALL SHEATHING CONT. OVER RIM JOIST. DO NOT BREAK AT DOUBLE TOP PLATE. EDGE NAILING TO TOP PLATE JIILAR SECTION PER :OR INFORMATION -IOWN FLOOR SHEATHING PER STRUCTURAL NOTES CONT RIM JOIST FLOOR JOIST/BLOCKING PER PLAN ALTERNATE SHEAR FLOW AT UPPER FLOORS 11$ DULL NLAI L NAIL/ EDGE EXTEND SHEAR WALL SHE, CONT. OVER RIM JOIST. I BREAK AT SOLE SHEAR WALL EDGE NAII RIM JOIST AND SIL FLOOR BOUNDARY NAILING PER DIAPHRAGM SCHED 2x SILL PLATE FLOOR JOIST "E: SIMILAR SECTION PER i2 FOR INFORMATION SHOWN ALTERNATE SHEAR FLOW AT LOWER FLOOR 118 ROOF BOUNDARY NAILING CONT. 2x BLKG WITH VENTING PER ARCHITECTURAL. SEE 8/S2 FOR ALTERNATE AT RAISED TRUSS HEELS. EDGE NAILING SHEAR WALL PER PLAN TYP SOLE PLATE NAIL/SCREW EDGE NAILING FLOOR BOUNDARY NAILING CONT. RIM JOIST SHEAR WALL SHEAR CLIPS, OR ALTERNATE PER 13/S2 EDGE NAILING SOLE PLATE NAIL/SCREW EDGE NAILING FLOOR BOUNDARY NAILING ROOF SHEATHING PER STRUCTURAL NOTES SW_P SHEAR WALL KEY Hi HOLD-DOWN ID STRAP TYPE HOLD-DOWN CENTER ON RIM JOIST AT hill III III III III III III I: UPPER FLOORS TYP. --Ir—�I—TT ==7ITI==n=- BLKG PER SCHED AT HORIZ. I 11 _ _ I I'� I_ _ 11 I I I I PANEL EDGE NAILING PANEL JOINTS w/ EDGE _ I _ J I I I _ll _ TYP. NAILING BOTH SIDES OF I — — j — I I F — -I' JOINT TYP. I I I I I I III PANEL EDGE NAILING ALL AROUND OPEINING LOCATE VERTICAL PANEL I I I I I I I I I PANEL EDGE NAILING JOINT ON STUD w/ EDGE I I I I I III I III I I I I I TYP. NAILING BOTH SIDES OF JOINT MIN (2) STUDS AT EACH I I I I III HOLD-DOWN UNLESS I I I I I I 0' NOTED OTHERWISE PER PLAN OR POST SCHEDULE TYP. I'U STRAP TYPE HOLD-DOWN TYPICAL PER PLAN TYP. PERFORATED SHEAR WALL TOENAIL ROOF TRUSSES PER PLAN H1 CLIP EACH TRUSS 2x6 STUDS AT 16" o.c. TYP FLOOR SHEATHING PER STRUCTURAL NOTES TYP FLOOR JOISTS PER PLAN SHEAR WALL SHEAR CLIPS, PRESSURE TREATED SILL PLATE PER SHEARWALL OR ALTERNATE PER 18/S2 SCHEDULE BOLT EMBED = 7" MIN. FLOOR JOISTS PER PLAN N. iFOUNDATION PER PLAN SHEAR WALL SCHEDULE AND NAILING DETAIL 1 5 ROOF BOUNDARY NAILING EDGE NAILING J SHEATH TRUSS PER TYP ROOF TRUSS SHEAR WALL SW1 EDGE NAILING ZZI I SHEAR WALL SHEAR 6r Q CLIPS TRUSS AND GABLE WALL BRACING PER TRUSS MANUFACTURER 2x6 STUDS AT 16" o.c. EDGE NAILING A TYP SOLE PLATE NAIL/SCREW EDGE NAILING FLOOR BOUNDARY NAILING CONT.RIM JOIST SHEAR WALL SHEAR CLIPS, OR ALTERNATE PER 13/S2 EDGE NAILING SOLE PLATE NAIL/SCREW EDGE NAILING FLOOR BOUNDARY NAILING SHEAR WALL SHEAR CLIPS, OR ALTERNATE PER 18/S2 FRAMING PERPENDICULAR TO WALL FRAMING PARALLEL TO WALL SHEAR WALL PER PLAN SOLE PLATE NAIL/SCREW EDGE NAILING FLOOR BOUNDARY NAILING 'ER PLAN 48"oc (4) 10d TO BLKG PRESSURE TREATED SILL PLATE PER SHEARWALL SCHEDULE. BOLT EMBED = 7" MIN. FLOOR JOISTS PER PLAN 2x BLKG AT 48"oc FOUNDATION PER PLAN TYPICAL STRUCTURAL WOOD WALL/SHEAR WALL ASSEMBLIES 1151 SHEAR WALL AT CANTILEVER 119 (3) 2x6 STUDS FULL HEIGHT, TURNED FLAT w/ (6) 16d TOP AND BOTTOM. NAIL TOGETHER w/ 16d AT 12" o.c. (4) %" x 8" LAG SCREWS LCE4 EACH FACE PSON KBS1Z JD BOTTOM aCE 4 VERT KNEE BRACE 1201 Ross Engineering Design Inc JOB # 20022 ryan. ross@rossengineer.com 4/7 2020 a�PN�A cl J B# 0 2 46411 ONA ELECTRONIC COPY ORIGINAL ON FILE AT ROSS ENGINEERING N 0m����w� 7>' L E N T °- N C O 0 N C C (0 L_2H Q°o y-2 o 2 c c UL_'Ua of in is O J N N C N 'O O@ 2@ O _O N 0 _y a' :5 y 3 U m N« t6 ° `n L- (O U C E N a ll. a O c N C C N— 0 N N O- N° 00 p W LL c io 0 3 m o m= 3 c d w ui F °- 0 O 'O N J °- 0. t6 N O 'O 0 Tea �0 0p�>�E�� J Q O F O UJ CV z00 uj Q C 0 Z z 01 O O 2 ULI O o v w uu () U. w Cn Z LLJ z Z W 06 0 Z 04 0 p CV QCN 00 m >_ 0 'L N d 0 0 Z FILE/ NO. DESIGNED BY RR DRAWN BY RR CHECKED BY RR SHEET: S2 PRINT DATE BE'SUB 0 TI m n CD mO� � Azo -4 N Z<0 o CD 5Cn m Cl) ------------------------------------------------------------------------------------------------------ -------------------------------------------------------------------------------------------------- I , LJ I' I ' II I' II '; II , 0 I , I , l ' II , I , LJ- ---; i I U. l ' - ' 'I I ' ;I Jr I; SW4 SW4 LJ ; Cli IF I' I; I, �Q i J 65 o� �° y°° 1 �5 o� o�y o�------------------------ r----- -------------------------------------------------- ------ ----------- ' , r------------------------------------------------------------i ;------J `---------J LJ L� , I LJ s to tP� I� y i GC r � r i i L' ^ ;I i i D I , SW2 n m---------------------------- ' ------------------- 0o Z I s I I T i i ThO Q _ I U) I /i II II I L------------- — ----- — ------ ---� l v l I' co In I I L----- Li I I' 'I I' I I; I� SW4 SW4 LJ o�y 0'y°� o�y LJ ��y°� Ilk SW1P Ilt r, ------------------------- to D =--------------- LJ L--------if-----; , I =Orn mr- O II I r D (n r —1 rn I II II o�= cn0o orm =c-)0 >� cn m m �j II z m ^' �� n ` C) X I• C DDym D 171 C/) v>Z =D Om0cW I II -n --I - J U II II I I II II II II II II II I 'I I L____________________J; n J I II II 'f_________l I I I IZ---------J I I LJ I � I II I I ;r , n I I ri i IL ij i it I ' I J ; L r----------- ' i i ' I , J " Lr,________� I --------------- SW3P ' I ' I I II I II I; ,I SW2 r-------------------------- r, r------' n n r-------7 I i ii II ' I ' n , " U u it Li ' L-------- — ----- —_____—_-' rl I, r, L -' Li u ri DIr m 0 09 m"Li 'i ii " _ H � „ r, ; _-- I I II I' I r-- --7 `;• •;� -------------7 C, --------------------------------------- ; ________ ' ==7 N i m 7 I �100 r- ;;arn i' _-_-_ -_ _o ___i SW5P z � O T in J L______J rn O � Z �' 1j z Z G) r z �_ a o ------ N z c�� o rn T O c,� O SW5P Li rn R NW o = 31 = m m Z m U) Z � 0 0 m < W � 0 -I ZCl) C\l N O N r 90 N o O No. Description � COONS RESIDENCE MARK & JENNIFER COONS 8427 202ND STREET S.W. EDMONDS, WA 98026 COPYRIGHT 2020 _ THE LEREN COMPANY INC. LIMIT OF LIABILITY NOTICE... Adoption of these plans to meet _ _r'.-- specific State, local codes, regulations, and specific site �1e9 conditions is the responsibility of the Owner and/or Contractor. The Laren Company Inc. or it's r _ employees shall not be held responsible for any damages relating to the accuracy and overall integrity of these plans. The Owner and/or Contractor - must inspect all dimensions and details in these plans for errors or omissions prior to construction. lerendesign.com THE LEREN COMPANY INC. PO BOX 12863 MILL CREEK, WA 98082 206.954.4145 PH email: info@lerendesign.com 7 6 5 4 3 2 1 49'-0" 4'-9Y4" ol 32'-6" 16'-6" ti I I I I Q Q r Mtn �--------L—I— I ,�� 8 ----- 0— T F-07 --- --- S�� � - -- -----I---- ----� �� IF -1 L F-03 0 -- —=- -- —=— ---ate L TYP1 8" CONCRET STEM WALL ON 16"x8" C NCRETE FOOTING (TYP. U.N.O00 i ST N -5" 6' 5" 6' 5" 66" 65" 6' 5" 6' 5" 2' 0" ' F-02 TYP Lg) CIRAWLSPA�E — — — — — — — — — — — — ---- — —----------------- - - - -------- - - - --- ------ - - - - - j _ 6 MIL. BLACK V.B. °o � S 1/ N 4'-3" 12'-3Y4" ~ 2'-101/" 16'42" F- F 7-06 F __lF7 6 N L J W y IL L 1, J 1:0 o a y °I TYP 2'-0" 65' -3Y" -5" '-5" -0"13' OY" ' I------------------- ---------------- - — - - jI � s ARAGE SLAB 4 o j F—o2 Ttiog 4" C NC. SLAB. SLOPE MIN. PER V-0" TOWARDS GARAGE DOOR. C A% 8-11/4 CONCRETE LANDING &STEPS U) TO GRADE PER I.R.C. -_-_-_�_-_-_-_-_-_-_-_-_-_-_I_ L I_-_-_-_-_-_-_-_-__ -_-_-_-_-_-_-_-_-_-_-_- o �--------------------_- m-_-_-__ Lo � l z J CON RE SLAB ` _x —I L Ll —I G — — — — — — — — NO BOLTS — — — — — — — — — — — 4" COMC. SLAB o/ R 10 — - - S- F=02 I7 .� — — — — — — — — — — — — — — 2" R161D INSULATION � � 6*2" 2'-0" TYP 5'-8" _ 5'-8" 5' 8" 5' 8" 2'-0" �- 01 _ S' N S _ r 2 2 TYP I I - _ - - - - - -� � � 2 I h'O� �A7 i 8" CONCRETE STEM WALL ` \A7 4 L` S 1 NO BOLTS. ON 16"x8" CONCRETE FOOTING (TYP. U.N.O.)-------- - - - - -- + - -- NO BOLTS --- ------------- --- --- bo L�--�--- 1 C F-02 �3 SOU } 4' 0%a" F-11 15'-8Y4" �ST�°S8 N CONT. FT'G UNDER GARAGE DR. 8'� �� o +` E F-03 j j tips tia��CCESS i i� - - - - - - - - - - - -----------�------ - �- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - �- - - - - - - - - "- - -'�_ - - _ - - - - - - - - - -�- j-. --- _ dk - - p II------1------------------- — — — — — — -- —-------------------- — — — 1---------- ----------------- -------------------------------- — — — — — — 0 O e/° Z s N GARAGE SLAB 4" CONC. SLAB. SLOPE MIN. %" PER V-0" TOWARDS GARAGE DOOR. � 1 7/ 10' 3" 1' 7%" 54" 9'_5%° w 6'-6" Q `.' 10'-0" I I I al c� LLI z ~I z 0 — — — — —-------------------------------------------------------------------------------------------- — — — — — — fib— — — — — — — — C I I I i �° s F 07 S� 2Y4" �nl F- 08 co B -=— —=--=--- _ _— 9 8 FOUNDATION VENT CALCS. 20_8 I. 4 (R408.1) PROVIDE 1 SQ. FT. OF VENTILATION FOR EVERY 300 SQ. FT. OF CRAWLSPACE. FOUNDATION VENTS SHALL BE EXTRUDED, LOAD BEARING 16"x8" VENTS. PROVIDE A MINIMUM OF (1) FOUNDATION VENT WITHIN T-0", BUT NOT WITHIN THE FIRST 1'-0" OF EACH CORNER OF CRAWLSPACE. ASSUMED VENTS ARE MIN. 15.5"x6" AND HAVE A NET FREE VENTILATION AREA OF .48 SQ. FT. N ---- ---- +T 0 CV M---------------- - FOUNDATION VENT CALCULATIONS CRAWLSPACE AREA 1427 SQ FT NET VENTILATION AREA / 300 SQ FT 4.76 NET AREA II I I i NUMBER OF VENTS REQ'D NET AREA / 0.48 10 01, OPTIONAL POWER VENT a CRAWLSPACE HEIGHT 3 285.4 CFM F-03 K - - - - -- -- -- J z S1 I I o I 0 CONCRETE LANDING & STEMS TO GRADE PER I.R.C. 37'-6" ol 11'-0" 10'4" lo J----------fi---------- ---- ----- I — - — - — - — - —i- — - — - — - — - — - — - — - — l — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — -i— - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - - . — - — - — - — - - - — - - e� N v 2 FOUNDATION NOTES • VERIFY ALL DIMENSIONS AND FIELD CONDITIONS PRIOR TO COMMENCING ANY WORK. • GENERAL CONTRACTOR AND/OR FOUNDATION CONTRACTOR SHALL VERIFY THE LOCATION OF ANCHOR BOLTS AND HOLDOWNS PRIOR TO POURING CONCRETE. • ALL FOOTING SHALL BEAR 18" BELOW UNDISTURBED NATURAL SOIL. FINISHED GRADE SHALL BE NO LESS THAN 12" ABOVE BOTTOM OF FOOTINGS. • TOP OF FOOTING SHALL BE LEVEL. BOTTOM SURFACE OF FOOTING SHALL NOT SLOPE MORE THAN 10%. STEP FOOTING AS NECESSARY TO MAINTAIN MIN. DEPTH OF FOOTING BELOW FINISHED GRADE. • FOUNDATION WALL SHALL EXTEND MINIMUM 6" ABOVE FINISHED GRADE. • ALL WOOD IN CONTACT WITH CONCRETE SHALL BE PRESSURE TREATED. • UNLESS NOTED OTHERWISE OR IN SHEAR WALL SCHEDULE, ALL ANCHOR BOLTS SHALL BE %" dia. x 10" AND EXTEND MINIMUM 7" INTO CONCRETE WITH MINIMUM SPACING OF 48" ON CENTER. EACH ANCHOR BOLT SHALL HAVE A YxYx.229" GALVANIZED WASHER. • SEE SHEARWALL & HOLDOWN SCHEDULES FOR SIZE AND PLACEMENT. • CRAWLSPACE ACCESS SHALL BE A MIN. OF 18"x24". OPENINGS THROUGH A PERIMETER WALL SHALL BE NOT LESS THAN 16"x24". (R408.4) • PROVIDE A 6 MIL. BLACK VAPOR BARRIER OVER ALL CRAWLSPACE AREAS. (R406.3.2) • PROVIDE 2" SAND OVER 6 MIL BLACK VAPOR BARRIER OVER 4" COMPACTED GRANULAR FILL UNDER ALL CONCRETE SLABS. • PROVIDE TEMPORARY BRACING AS REQUIRED UNTIL ALL PERMANENT CONNECTIONS ARE IN PLACE. • ALL ISOLATED SPREAD FOOTING TO BE 24"x24"x8" REINFORCE FOOTINGS WITH (2) #4 BARS EACH WAY UNLESS NOTED OTHERWISE IN PLAN. • FOUNDATION WALLS THAT RETAIN EARTH AND ENCLOSE INTERIOR SPACES AND FLOORS BELOW GRADE SHALL BE DAMPPROOFED FROM TOP OF FOOTING TO FINISHED GRADE. (R406.1) • SEE SIMPSON RECOMMENDATIONS FOR HOLD DOWN PLACEMENT. COORDINATE LOCATIONS WITH DOOR & WINDOW ROUGH FRAMING TO PROVIDE ACCURATE DIMENSION FOR OPENINGS. �3�s yO°8 CONCRETE LANDING & STEPS c? TO GRADE PER I.R.C. 0 I F-03 F-03 I F-03 F-03 I A----- ---!93/ - - - - - - - -------------- 6" 10' 3 4 Ir 10' 6" 10' 3Ya" 1 10 4'-8 - Ir 42'-0" 1 14 13 12 13'-6" 14'-9%" 17'-2 2" I . T-6" I . 4'-9Y4" 65'-6" N N CONCRETE FOOTING SCHEDULE SYM. FOOTING SIZE RE -BAR PLACEMENT F-01 *16"x8" CON'T. (2) #4 CON'T. F-02 24"x24'W" (2) #4 EA. WY. F-03 *24"x24'W" (2) #4 EA. WY. F-04 *30"xW'W" (3) #4 EA. WY. F-05 36"x36"x8" (3) #4 EA. WY. F-07 *36"x36'W" (3) #4 EA. WY. F-08 *42"x42"x8" (4) #4 EA. WY. F-09 44"x44"x12" (4) #4 EA. WY. F-10 48"x30"x8" (4) #4 EA. WY. F-11 48"x24"x8" (4) #4 EA. WY. F-12 76"x24'W" (4) #4 EA. WY. NOTE: *EXTERIOR FOOTINGS SHALL BE MIN. 18" BELOW GRADE AND REST ON BEARING SOIL. NOTE Is ALL FOUNDATION WALLS TO BE 8" UNLESS CALLED OUT OTHERWISE. LEGEND STEM WALL FOOTING CONCRETE SLAB FOUNDATION PLAN SCALE: 1/4" = 1'-0" 4/7 2020 y p,N N RCS WASy�Nc�S' - JC ELECTRONIC COPY ORIGINAL ON FILE AT ROSS ENGINEERING Lu N V co Lu o Q Z Z O 2 O o cl)V W Lu Lu (j L Lu Z W Z z W 0 od z O ti 0 04 Q lq- V 00 w �a 0 a U) 0 6 z PROJECT NO. 200101 TL DESIGNED BY DRAWN BY TL & RM CHECKED BY RR SHEET: PRINT DATE 4/5/202 Feb 17 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT POST, CAP & BASE SCHEDULE SYM. POST CAP BASE NOTES: P-01 (1) 2x— STUD w/ (1) TRIMMER (4)16d NAIL (DBL. TOP PLATE) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. (8) 16d NAILS STUD TO HEADER P-02 2x— STUD w/ (2) TRIMMERS (4) 16d NAIL (DBL. TOP PLATE) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. (8) 16d NAILS STUD TO HEADER P-03 (2) 2x— TRIMMERS (4)16d NAIL (HEADER) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. P-04 (2) 2x— STUDS (4) 16d NAIL (DBL. TOP PLATE) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. P-05 44 DF#2 * SIMPSON PC44 SIMPSON A34 * OPTION: 2x4 CLEAT EA. SIDE NAILED w/ (2) ROWS OF 10d @4"O.C. P-06 46 DF#2 * SIMPSON PC44 (2) A34 * OPTION: 2x4 CLEAT EA. SIDE NAILED w/ (2) ROWS OF 10d @4"O.C. P-07 44 DF#2 (4) 16d NAIL (SUB -FLOOR) A34 P-08 (2) 2x4 P.T. CRIPPLES (2) 16d TOE NAILS A34 ATTACH TO CONCRETE WALL w/ 2 Y2" CONCRETE NAILS (2)ROWS 16"O.C. P-09 (3) 2x— STUDS (4) 16d NAIL (DBL. TOP PLATE) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. P-10 (4) 2x— STUDS (4) 16d NAIL (DBL. TOP PLATE) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. p-11 (5) 2x— STUDS (4) 16d NAIL (DBL. TOP PLATE) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. P-12 2x— STUD w/ (3) TRIMMERS (4) 16d NAIL (DBL. TOP PLATE) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. (8)16d NAILS STUD TO HEADER P-13 2x TRIMMER+(2) STUDS+TRIMMER (4)16d NAIL (DBL. TOP PLATE) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. (8)16d NAILS STUD TO HEADER P-14 4x4 PT HF#2 PC4Z OR EPC4Z PBS44A P-15 6x6 PT HF#2 ECC66 PBS66 P-16 I 6x8 DF#1 CC78 WITH ROTATED STRAPS CB68 LONG AXIS PARALLEL TO GRID E INOTE:1 SOLID BLOCKING BETWEEN FLOOR @ POINT LOAD BLOCKING TO BE EQUAL TO OR GREATER THEN THE POST ABOVE BEAM SCHEDULE SYM. BEAM BM-01 48 DF#2 OR BETTER BM-02 410 DF#2 OR BETTER BM-03 P.T. 48 SEE 20/S2 BM-04 3.5"x9.25" PSL BM-05 3.5"x11.875" PSL BM-06 5.25"x11.875" PSL BM-07 7"x11.875" PSL BM-08 1.75"x14" LVL BM-09 5.25" x14" PSL BM-10 3.5"x10.5" GLULAM BM-11 5.5"x15" GLULAM BM-12 5.5"x19.5" GLULAM BM-13 6.75"x21" GLULAM BM-14 1.75"x11.875" LVL BM-15 5.5"x10.5" GLULAM BM-16 3.5"x9" GLULAM BM-17 412 DF#2 HANGER SCHEDULE SYM. HANGER H-01 L70 H-02 IUS2.37/11.88 H-03 LU210 / LUC210 H-04 JB210 H-05 HUS210-2TF H-06 HUC48 H-07 HUCQ612-SDS H-08 HGUS5.50/14 H-09 HUCQ1.81/11-SDS H-10 HUCQ412 H-11 HHUS7.25/10 H-12 BA410 MAX NAILS H-13 HUCQ410 H-14 LU210-2 / LUC210-2 NOTE: HANGERS NOT CALLED OUT IN ROOF PLAN SHALL BE PROVIDED BY TRUSS ENGINEER i I I (D - ------------------i- -- I I I I I I I I C C a • . ° ••----- 8 . - °. I, - — — —4-- — — — — — — — — —I — — — — — — — I I I I � f--------------i— --- —------------------------------------ ------------------------------- I a I�a I ---��--------------! - - - ------------------------------------!-------------------------------- I= i �I D -- I I °I 1�1 i I I ° I I1I.' GARAGE SLLAB I ' 4" CONC. SLAB. SLOPE 'MIN. %8' PER 1'-0" TOWARDS GARAGE DOOR. I ,I I .•I I•°i I I L' i I I I• I a 9 8 7 6 5 4 3 2 1 I I I I I I I I I I I I I I I I I I I I I I I I I I I C— — — 4.°T --------------------------------------------------------------------------------------------------------I -------------------------- r .I ai i 'I I I C i I � 14 13 12 11 10 LIN MAIN FLOOR FRAMING NOTE ! • INDICATES: POINT LOAD ABOVE SOLID BLOCKING REQUIRED NOTE ! ALL FLOOR FRAMING MEMBERS TO BE 2x10 HF#2 OR BETTER @ 16" O.C.(U.N.O.) LEGEND T CONCRETE WALL UNDER WALLS/ FIXTURES OVER FLOOR PERIMETER FLOOR JOISTS HEADERS & BEAMS CONCRETE SLAB 0 4/7 2020 � RCS of WAS,y,, s` 11 ELECTRONIC COPY ORIGINAL ON FILE AT ROSS ENGINEERING V Z N w 0 0 �� a IL Y 2 01 J W d m W �, N GS OJ 7 � U �O� co co 0 Z1p N w 99 0 m Lu m J 0 W E O V C + .N �� 1�[I111 1111!I � Ci uj a�i m2o �v �-ocoNo ZUEN'm=1 Z5 a>rnCm�c'�o NZO y U'j O O CD N U o ~ m� a 0 N 2 0 C C C U.L.. 6� 2 0 = O J m— -o d v a m 2 m o°= r' w+ 2 V @ N .`2 N.-.. El. -m N �Um O 5.9 E a W J O U C N C C O Z O d U1 a N O O 111E 60. O N J O' O. (0 2 N V t w 0 r d d o E m d a° J Q O H Lu N V co z Q Lu o Q Z Z O O o cl) U Lu Lu w W (j L Lu Z w cj) Z z W od Z N 0 O 0I.L ti Q C\l V 00 w 0 c 0 Q. �L rn m 0 0 z PROJECT NO. 200101 DESIGNED BY TL DRAWN BY TL & RM CHECKED BY RR SHEET: S5 PRINT DATE 4/5/202 13 Feb 17 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT POST, CAP & BASE SCHEDULE SYM. POST CAP BASE NOTES: P-01 (1) 2x- STUD w/ (1) TRIMMER (4)16d NAIL (DBL. TOP PLATE) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. (8) 16d NAILS STUD TO HEADER P-02 2x- STUD w/ (2) TRIMMERS (4)16d NAIL (DBL. TOP PLATE) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. (8) 16d NAILS STUD TO HEADER P-03 (2) 2x- TRIMMERS (4)16d NAIL (HEADER) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. P-04 (2) 2x- STUDS (4) 16d NAIL (DBL. TOP PLATE) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. P-05 44 DF#2 * SIMPSON PC44 SIMPSON A34 * OPTION: 2x4 CLEAT EA. SIDE NAILED w/ (2) ROWS OF 10d @4"O.C. P-06 46 DF#2 * SIMPSON PC44 (2) A34 * OPTION: 2x4 CLEAT EA. SIDE NAILED w/ (2) ROWS OF 10d @4"O.C. P-07 44 DF#2 (4) 16d NAIL (SUB -FLOOR) A34 P-08 (2) 2x4 P.T. CRIPPLES (2) 16d TOE NAILS A34 ATTACH TO CONCRETE WALL w/ 2 Y2" CONCRETE NAILS (2)ROWS 16"O.C. P-09 (3) 2x- STUDS (4) 16d NAIL (DBL. TOP PLATE) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. P-10 (4) 2x- STUDS (4) 16d NAIL (DBL. TOP PLATE) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. P-11 (5) 2x- STUDS (4) 16d NAIL (DBL. TOP PLATE) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. P-12 2x- STUD w/ (3) TRIMMERS (4)16d NAIL (DBL. TOP PLATE) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. (8)16d NAILS STUD TO HEADER P-13 2x TRIMMER+(2) STUDS+TRIMMER (4)16d NAIL (DBL. TOP PLATE) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. (8)16d NAILS STUD TO HEADER P-14 4x4 PT HF#2 PC4Z OR EPC4Z PBS44A P-15 6x6 PT HF#2 ECC66 PBS66 P-16 6x8 DF#1 CC78 WITH ROTATED STRAPS CB68 LONG AXIS PARALLEL TO GRID E NOTE: SOLID BLOCKING BETWEEN FLOOR @ POINT LOAD BLOCKING TO BE EQUAL TO OR GREATER THEN THE POST ABOVE BEAM SCHEDULE SYM. BEAM BM-01 48 DF#2 OR BETTER BM-02 410 DF#2 OR BETTER BM-03 P.T. 48 SEE 20/S2 BM-04 3.5"x9.25" PSL BM-05 3.5"x11.875" PSL BM-06 5.25"x11.875" PSL BM-071 TI1.875" PSL BM-08 1.75' 14" LVL BM-09 5.25" x14" PSL BM-10 3.5"x10.5" GLULAM BM-11 5.5"x15" GLULAM BM-12 5.5"x19.5" GLULAM BM-13 6.75"x21" GLULAM BM-14 1.75"x11.875" LVL BM-15 5.5"x10.5" GLULAM BM-16 3.5"x9" GLULAM BM 17 4x12 DF#2 HANGER SCHEDULE SYM. HANGER H-01 L70 H-02 IUS2.37/11.88 H-03 LU210 / LUC210 H-04 JB210 H-05 HUS210-2TF H-06 HUC48 H-07 HUCQ612-SDS H-08 HGUS5.50/14 H-09 HUCQ1.81/11-SDS H-10 HUCQ412 H-11 HHUS7.25/10 H-12 BA410 MAX NAILS H-13 HUCQ410 H-14 LU210-2 / LUC210-2 NOTE: HANGERS NOT CALLED OUT IN ROOF PLAN SHALL BE PROVIDED BY TRUSS ENGINEER 9 8 7 6 5 4 3 2 1 I I I I I I I I I I I I I I I I I Q H. 2'-0„ O.H. I I t-� �Ncv—) �H �o J— — — — — —— — — -- — -- I ---------------7---- ------ -i--- J - ----- -- - IwT�--- A-- co M - --------------I Q BM-10 j LJ Luii ii = —=1= ==i I� I-- --- --- --- --- - - L-� A _ ---� i(NOTCH OVER BEAM) Ll I I I I I r I Hm l 1 H �H m 4� i = I 11.875" BCI 60 0-1.8 A , Ca 16"O.C. I-- '° o� B -05 C° R -----------L-- --- ---------------- — -- -- — -- -- — — — L— — -- _j --------------------- I — --- ------------- 0] "I ��` 6 I I A S2 5 I FOR \OA o y S2 SOLID BLOC SOLI BLO K ` � OVE BEAM BEA B 05 A OVER BEA B --- --- --- --- ---- --- --- ---- --- --- I --- --- - T r-- Lm' __ N S2 1.875" BCI 6 0-1.8 16"O. `. r S2 I ,o A I A \\ I ODD \ RIDGE \�`� I Q BM 05 'O 0 i BM-02 A - -- -- ii -- ------NI -- --- ---------III -- — aI -- —— --- - - — ,-- ---— - ----- - ----- ti`90�— — — - -- -- -- - ------- ----- - - - F - - -- -- --- II II II - --- - - — -- - ----- ----- ------------- ---------- �--------- —---- ----- ------, ---------------- r I I I I I \\\--------------, ' o I / `O I I I I � )C-4 I i SOLI BLO K I I BM 05 �- OVE BEAM___ ; I j I M-01 j LL A A Q I I i ----------------- 0 N v o ZQ_ OI� I I 1.875" BCI 60 0-1.8oGABLE --- --I - G - - - F r ---- ---- r---- ----- -- ----—-- -- — —— ----- ---- ----- I I I I 16"0. . A I 4-_ 2 t 2x1 LANDING ►- 8 -� A I �O i i `� I CA 'T �00 it N J 2 i 16"0. p - - - , l w �- - 3 2x12 STAIR _ A7 o O I 2 i BM 06 'Q O i I I I t (3) 2x12STAIR - L1 - - - I I it STRINGERS co - - - - - - - - o - - -SSTRINGER' - - - - - I A7 I \O I ,1I, t Aof m I BM-1 I I STRI IpERS � �/ — _ _GIRDER -TRUSS - __----- 1 -m -I --- -- --- --- - ------ L- - -- �- -----J /01% o- - R I (3) 2x1 STAIR 8 I Lu ---- --- r r 7 C J---------- - - - - - - --------------- F-- - --_ --_ -- - - - --_ -- — — - -_ - _ _ r- - �_�_-_-_-_-_-_ DBL IST - 1 I - {3BL iST- \n=031 cn- - -- ----Jw- - t - - - - - - - - - -O��ci ­12\ I I \ -- �o \ II ----------N 1� o wN 08 w o� o(3) 2x1g STAIRI--- � I STRINGERS I 1 I I co E `o o N N �, 0 C m 2x10 ANDI 3 2x12 STAIR o 9 I BM-12 `�I m BM-09 1142 H O BM-15 O O O A Z---- 2x1 LANDING -`n I ----------------- Q� ------ -Q Q - -- �N - Q - @6"O.0 m STRINGERS m 160 A -- -- - - - - - - - -- - - - - -� ---- - --- -o - ---- - -- --- I I I E-- I I II O0) (D ------- uo I I I I I I I I I I I I I I I I I I I I I I I I I I � I \Qo I 6�-1211 I II I i I ----------------------------- '_L - 6..o A O.H. 6IIIo- 13 14" B01 600041.8 DF 16"0. m r, N_ !x8 H # 2 RAF 24"O.0 �— — — --- — — — — A — — —-- ---- --- 1� N � H 12 ■oi c� w 2 cj cy B -02 A - - - -- ---- =- - IF --- 1� — — — --- — — — --- -- — — — -- — — o = N o h Q% I I I I I I I I I 812 I A I i I I I , ------- -- -- A - - -- -- ` I O 9 2x8 LE GER WIT 2 SDS 15312 SPACED 1 2'-6" 4" TO HACH GABLE TRUSSI STUD (a "O.C. �:i 1 O.H. I I I I I I I � I I I I I I I I I — — — — — — — ------------------------------------ :].? I 11 10 2ND FLOOR FRAMING SCALE: 1/4" = 1'-0" FLOOR TRUSS NOTE: THIS LAYOUT IS FOR SCHEMATIC PURPOSES ONLY. REFER TO TRUSS FRAMING PLANS PER MANUFACTURER AND PREPARED BY A LICENSED TRUSS ENGINEER. NOTE ! ALL ROOF FRAMING MEMBERS TO BE MANUFACTURED TRUSSES @ 24" O.C.(U.N.O.) NO CALLOUTS SHALL BE HEADER: BM-01 COLUMN: P-01 (ea. side) LEGEND TRUSSES TRUSSES (TOP CHORD) OVER FRAMING WALLS UNDER WALLS/ FIXTURES OVER HEADERS &BEAMS FLOOR PERIMETER FLOOR JOISTS LANDING JOISTS STAIR STRINGERS LOWER ROOF LINES 2'-6" O.H. I 4/7 2020 �l PN N. ?o s` 0 11 ELECTRONIC COPY ORIGINAL ON FILE AT ROSS ENGINEERING (V Z � N w 0 0 a �� EL Y x coJ W d m GS W �, N O J L7 U �Oco co U 0 ZcoN` Lu N — 99 0 m Lu m J 0 W O V C + .N c N ry N Z U E NZZ 8!E oi'a m"N�Cma C C U U 2 y C° L' � Omt� m� o mw�'m GE y a WJ5cn 0cdON a°°«��ma�jOo 8-,o o ° ��o �s g =--o Lu aa'�y�°.am��,�vt J Q O H Lu N V co Lu (� p Q Z z OG O o cn U w Lu LU (j L Lu cl) Z W Z z W � N 0 O N 111 0 Q C\l V co w 0 c 0 Q. rn m 0 O z PROJECT NO. 200101 DESIGNED BY TL DRAWN BY TL & RIM CHECKED BY RR SHEET: S6 PRINT DATE 4/7/2020'� Feb 17 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 'M. POST CAP BASE NOTES: G .01 (1) 2x_ STUD w/ (1) TRIMMER (4) 16d NAIL (DBL. TOP PLATE) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. (8) 16d NAILS STUD TO HEADER 9 8 7 6 5 4 3 2 1 -02 2x- STUD w/ (2) TRIMMERS (4) 16d NAIL (DBL. TOP PLATE) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. (8) 16d NAILS STUD TO HEADER -03 (2) 2x- TRIMMERS (4) 16d NAIL (HEADER) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. \ -04 (2) 2x- STUDS (4) 16d NAIL (DBL. TOP PLATE) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. �\ .05 4x4 DF#2 " SIMPSON PC44 SIMPSON A34 * OPTION: 2x4 CLEAT EA. SIDE NAILED w/ (2) ROWS OF 10d @4" O.C. -06 4x6 DF#2 ` SIMPSON PC44 (2) A34 " OPTION: 2x4 CLEAT EA. SIDE NAILED w/ (2) ROWS OF 10d @4" O.C. -07 4x4 DF#2 (4) 16d NAIL (SUB -FLOOR) A34 -08 (2) 2x4 P.T. CRIPPLES (2) 16d TOE NAILS A34 ATTACH TO CONCRETE WALL w/ 2 %" CONCRETE NAILS (2)ROWS 16"O.C. 1 -4 M O.H. Q� .09 (3) 2x_ STUDS (4) 16d NAIL (DBL. TOP PLATE) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. - -1- - - - - - - - - - - - - - - - - - - - - - - - - - - - ---_---- -- \- -' - - - - - - - -------- - - - - --- N-------------------- --- t— — —--------------- .10 (4) 2x_ STUDS (4) 16d NAIL (DBL. TOP PLATE) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. .11 (5) 2x_ STUDS (4) 16d NAIL (DBL. TOP PLATE) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. n /� _ _ _ _ _ __ _ — —_---_ IVI � o Q/ GABLE -12 2x_ STUD w/ (3) TRIMMERS (4) 16d NAIL (DBL. TOP PLATE) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. (8) 16d NAILS STUD TO HEADER -13 2x TRIMMER+(2) STUDS+TRIMMER (4) 16d NAIL (DBL. TOP PLATE) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. (8) 16d NAILS STUD TO HEADER I. 1 O I I II II -14 44 PT HF#2 PC4Z OR EPC4Z PBS44A -15 6x6 PT HF#2 ECC66 PBS66 II U) Lu 16 6x8 DF#1 CC78 WITH ROTATED STRAPS CB68 LONG AXIS PARALLEL TO GRID E A O i i I I a )TE: SOLID BLOCKING BETWEEN FLOOR @ POINT LOAD BLOCKING TO BE EQUAL TO OR GREATER THEN THE POST ABOVE i I I �7:12 0712 00 Of LLof II II I of > I I I = Q W BEAM SCHEDULE 'M. BEAM -01 48 DF#2 OR BETTER -02 4x10 DF#2 OR BETTER -03 P.T. 48 SEE 20/S2 -04 3.5"x9.25" PSL -05 3.5"x11.875" PSL -06 5.25"x11.875" PSL -07 7"x11.875" PSL -08 1.75"x14" LVL -09 5.25" x14" PSL -10 3.5"x10.5" GLULAM -11 5.5"x15" GLULAM -12 5.5"x19.5" GLULAM -13 6.75"x21" GLULAM -14 1.75"x11.875" LVL -15 5.5"x10.5" GLULAM -16 3.5"x9" GLULAM I L_ J L_____ ___J I --- 0- O Z Q \ O�II --- I ----- ---- ---- ----- ----- -- -;- I - -- ---------� I I I II I I I I I I I 00 j]f LL Nxw - O 2'-6" O-.H. - - - ----- ----- -------------- - - I I I - - - - -- - -- GABLE I \0 - - - - - - \Osr BM 03 ----i - -----------------------f ---- I II II ____ _____ ____ _____J _____II II I L_j II----n- ; i I ILL m i a 2x8 RAFTERS I U I I jl I I I L---- ----- ----- -----� �- ----- ------- yII, ----J JJJ I I C--- ---� I ----JI ----- I I I I II N I I III I I III A � C'M RIDGE N � II l\�\ G ID N cfl I I A 7S-17I � � X I iii w I I I I iii M III III n I III II Tj -17 4x12 DF#2 --- - -- -- -- -- III — ---- I I ------- III II con /10 c w RIDGE r oBM 03 � I --- -- -� --- ------ ----- r-- III i ii------ '---- I 15 I I --- ------------------------------------------------------- - I-- -- - - I -I - �- - --- - II ---------- - ---------- ---- -T-------T---------T------------ - L---- ----- -, - --- -- -- I� --- -- II -- --- -- -- ------- ------I- _____ LI�_____ l i I I —__ I I I I I I �` U) '� i i I 2x8 RAFTERS I II I � li 7:12 7:12 A I I I I I I iiI ,�� I I I ��� O I I I X I I I , U I I R 5t BM 03 GABLE WALL , Q i r I I I I I I I I I I I Till 2 2x12 RAFTER i i i i i I I I O. . - - - - - - - A7 00 1 2 T m A7 I I I I (� `?` 1� Q I I I I I I I I -- � wIll Lu L u Fc? O m i i i i I; O W W J Q W J �j��-_ — —_ I --_t z N � w CW9 � O W /I --I I -i i — \ — — — L--------- --J Q O O I O, N LL W Lu O O I I I I '� - - -- ----- - -J ------ LL I� --- I J �� o W N m 4:1208> ? a I I Z L _______ __ i CJ I o I� O z ------ --L- - ----- r -1 Z Q N _j V - ----- O W W Z d J o O w O z Q z U) H0De -- --- --- --- -- -- --- --- --- -- - --- -------------------------------------------- — — — --- --- ---- D---- ----- - ----- ----------------- --II II II IT --i --------------------------- J-- —LL ---- - --- -- - -- -rN W L----------iL-------- ] S� - - -v - - - - -- - - -N wI II I (D L____ _ ___j i <<FyI i Q GABLE I I I I L� Li--- - ---- Q� O.H. U) 2x8 RAFTERS j Ij 7 ---- --- 7 rl Ln �] L-------1r- ---� � RIDGE N LoRIDGE I I I I MFG. S SSOR TRUSSES N 24"O.C. 77 ILq I II II L0 ILL 15 I I Ii ii I I I /� SZ I y IL ----- ----- ---- �� - II .O I --- II ------------ IIII--------------------- I ---- - I I u S1 I ----- O�� M-03 IC--- ---------- �o 1' 0" 0.H. �h I chQ I I I I I I I I I I I I I I g-------- a------------------ - -i --------------------IL------�------------ I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I A---------------------------------------------------------------------I--------------------------------------------------- i -------------------------- 14 13 12 11 10 HANGER SCHEDULE SYM. HANGER H-01 L70 H-02 IUS2.37/11.88 H-03 LU210 / LUC210 H-04 JB210 H-05 HUS210-2TF H-06 HUC48 H-07 HUCQ612-SDS H-08 HGUS5.50/14 H-09 HUCQ1.81/11-SDS H-10 HUCQ412 H-11 HHUS7.25/10 H-12 BA410 MAX NAILS H-13 HUCQ410 H-14 LU210-2 / LUC210-2 NOTE: HANGERS NOT CALLED OUT IN ROOF PLAN SHALL BE PROVIDED BY TRUSS ENGINEER ROOF PLAN NOTES • SEE DESIGN LOADS AND/OR STRUCTURAL NOTES FOR GROUND AND ROOF SNOW LOADS. • FOR MANUFACTUREDED TRUSS ROOFS: ROOF PLAN IS FOR SCHEMATIC PURPOSES ONLY. ACTUAL ROOF PLAN TO BE DESIGNED AND ENGINEERED BY A LICENSED TRUSS ENGINEER. RAFTER FRAMING PER PLAN. • TRUSS LAYOUT TO BE REVIEWED AND APPROVED BY THE TRUSS MANUFACTURER PRIOR TO CONSTRUCTION. • SHADED AREAS INDICATE OVER -FRAMING. • LOCATE DOWNSPOUTS PER SITE CONDITIONS AND PER GENERAL CONTRACTOR. • INSTALLATION OF ALL ROOFING AND WALL FLASHING SHALL BE TO INDUSTRY STANDARDS AND IN COMPLIANCE WITH CURRENT CODES. • PROVIDE CONTINUOUS ALUMINUM GUTTERS ON FASCIA AS SPECIFIED IN DETAILS. • SKYLIGHT SIZES, IF ANY, ARE APPROXIMATE. CONTRACTOR TO VERIFY ACTUAL ROUGH OPENING SIZE PER MANUFACTURER SPECIFICATIONS. • PROVIDE SOLID BLOCKING OVERALL SUPPORTS. • PROVIDE MIN. 22"x30" ATTIC ACCESS WITH APPROVED WEATHERSTRIPPING. IF ACCESS IS IN A GARAGE, A SELF CLOSING MECHANISM MUST BE INCORPORATED. • 16d @ 8"o.c. END TRUSS TO TOP PLATES. (TYPICAL AT ALL GABLE ENDS) • ATTICS WHERE THE MAX. CLEAR HEIGHT BETWEEN JOIST AND RAFTERS IS MORE THAN 42", OR WHERE THERE ARE TWO OR MORE ADJACENT TRUSSES WITH THE SAME WEB CONFIGURATION CAPABLE OF CONTAINING A RECTANGLE 42" HIGH BY 24" WIDE OR GREATER, MUST BE CONSIDERED ATTIC WITH LIMITED STORAGE. • ATTIC SPACE SERVED BY A FIXED STAIR SHALL BE DESIGNED TO SUPPORT THE MIN. LIVE LOAD FOR SLEEPING ROOMS. ATTIC VENTILATION CALCULATIONS ATTIC VENTILATION (R806.1 & 806.2) PROVIDE 1 SQ. FT. OF ATTIC VENTILATION FOR EACH 150 SQ. FT. OF ATTIC AREA. EXCEPTION: PROVIDE 1 SQ. FT. OF ATTIC VENTILATION FOR EACH 300 SQ. FT. OF ATTIC SPACE WHEN NOT LESS THAN 40% AND NOT MORE THAN 50% OF THE REQUIRED VENTILATION AREA IS PROVIDED BY VENTILATORS LOCATED WITHIN THE UPPER PORTION OF THE ATTIC OR RAFTER SPACE. UPPER VENTILATORS SHALL BE LOCATED NOT MORE THAN 3 FEET BELOW THE RIDGE OR HIGHEST POINT OF THE SPACED MEASURED VERTICALLY WITH THE BALANCE OF THE REQUIRED VENTILATION PROVIDED BY EAVE OR CORNICE VENTS. WHERE THE LOCATION OF WALL OR ROOF FRAMING MEMBERS CONFLICTS WITH THE INSTALLATION OF UPPER VENTILATORS, INSTALLATION OF MORE THAN 3 FEET BELOW THE RIDGE OR HIGHEST POINT OF THE SPACE SHALL BE PERMITTED. UPPER ROOF VENT CALCULATIONS ROOF AREA 2550 SQ FT REQUIRED ROOF VENTILATION AREA / 300 8.50 SQ FT 40-50% IN UPPER & LOWER ROOF ROOF VENT AREA / 2 4.25 SQ FT VENT BLOCKS IN EAVES BLOCKS = AREA/ 0.074 58 ROOF VENTS IN UPPER 40-50 % OPTION 1: AF50 ROOF JACK = AREA/ 0.333 13 OPTION 2: (ridge vent) CORAVENT V300 = AREA/ 0.094 45.2 FEET ROOF PLAN SCALE: 1/4" = V-0" FOR SCHEMATIC PURPOSES ONLY. REFER TO TRUSS FRAMING PLANS PER MANUFACTURER AND PREPARED BY A LICENSED TRUSS ENGINEER. NOTE ! ALL ROOF FRAMING MEMBERS TO BE MANUFACTURED TRUSSES @ 24" O.C.(U.N.O.) NO CALLOUTS SHALL BE HEADER: BM-01 COLUMN: P-01 (ea. side) LEGEND TRUSSES RAFTERS TRUSSES (TOP CHORD) OVER FRAMING GIRDER TRUSS 2ND WALLS UNDER jfJJl1 MAIN WALLS UNDER HEADERS & BEAMS ROOF LINES LOWER ROOF LINES 4/7 2020 yPN N. Ro WAsy��cS Z J Ba 0 � 46411 4NA ELECTRONIC COPY ORIGINAL ON FILE AT ROSS ENGINEERING U Z N W O co Q > U CL Y 2 a wad w�� OJ V U �o Z 00 N N W o W m o W H O u + W U z U E� Na} t0 U O O.dU T Oa.3LU E N c F O. O rh N O m C C V `O 9 N O = O C y J = Z Q 2 fN m U y i .z o d.N E c a w 0, n- O a o 0 0= o Oww0.�Oo3mi."m�.�3_mo� U W o npO� o w s E. P> F E m J Q O F O Lu N V Lu (l) p Q Z z O O � 0 w Lu Lu (j Lu Z LuLu cj) Z L.f_ z W 0 06 z c) ti 0 N Q V 00 w �a 0 c O s- t� w m 0 6 Z PROJECT NO. DESIGNED BY 200101 TL DRAWN BY TL & RM CHECKED BY RR SHEET: S7 PRINT DATE 4/7/202 Feb 17 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT