Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
APPROVED PLN BLD STM ENG 82nd Townhouses Civil Plans 2020-11-11
U o � �o I Q) EN 4o N .c I � oa on N o 0 co o k > k'4 NZZ LAW w' 00 qq N 0 0 zI� LEGAL DESCRIPTION ABBREVIA TED LEGAL: HAWARDEN TRACTS BLK 000 0-00 - LOT 6 EXC W 15OFT THOF BASIS OF BEARINGS THE MONUMENTED CENTERLINE OF 212TH ST. S. W., AS THE BEARING OF N 89 0647" W. BENCH MARK FOUND REBAR W/CAP STAMPED "LSA 22969" DUE SOUTH OF THE SOUTHEAST PROPERTY CORNER. (PER GPS OBSERVATIONS) ELEVATION : 421.45' DATUM : NA VD 88 UTILITY NOTE ALL NEW UTILITIES ARE REQUIRED TO BE INSTALLED UNDERGROUND. BUILDING HEIGHT CALCULATIONS (AEG) ELEVA TION A: 423.32 ELEVA TION B. 421.33 ELEVA TION C. 421.80 ELEVA TION D. 423.86 TOTAL: = 1690.31 AVERAGE ORIGINAL GRADE (AOG): = 422.58 MAIN FINISHED FLOOR: = 422.75 ROOF A T RIDGE. = 446.75 ALLOWABLE BUILDING HEIGHT = 447.58 (422.58 + 25 FT) LOT COVERAGE LOT AREA: 11,520 SF ALLOWABLE COVERAGE (459). 5,184 SF TOWNHOUSE BLDG, COVERED PATIO & GARAGE. 4,249 SF PERCENT COVERAGE. 36.99' IMPERVIOUS AREAS PROJECT SI TE CA 7EGORY CA TEGORY 2 DISCHARGE LOCATION: CI TY'S MUNICIPAL SEPARATE STORM SEWER SYSTEM (MS4) N 89 06'47" W 488.01' - C�I�If•�LSiI�I�I�I�lrfil�] NE 114, SEC 30, TWP 27N, RGE 4E, W.M. 82ND TOWNHOUSES I ,I I _ I 10' BSBL - I 0 I I I 1 to I �I I� 004674000p0601 I' �irn�nir� I YL!/�vuL� HAWARDE� TRACT VOL. 14, I AGE 69 I, 00467400001100 CIVIL ENGINEERING PLANS FOUND CASED CONC. MON. W/ FOUND CASED CONC. MON. W/ 1-1/2" BRASS DISK & 'X" 1-1/2" BRASS DISK & 'Y' -19. DOWN -212TH ST SW - - DOWN 0.15'. VISITED 5- NO 89 06'47" W 381.55' (BASIS OF BEAR/NG0.25'. VISITED 5-20-19. —I I1 II I II ; �'30' 00467400000500 I I � I I I I FO D REFt kR W/CAP -' ---. \ AMPED"4SA 22969" I I II T CORNE I I I II ------- 16.4' - ------ --- = - 16.61' , 1 III-------J �L-.;-----J i L,- COVERED PROPOSED TOWNHOUSES I / COVERED PORCH MAIN FF 422.75 PORCH GARAGE F - 422.25 UNl T 1 UNIT 2 UNIT 3 UNIT 4 I P i / 1 1nAa7nnnnnann 10' JOINT I U 7 15' I� BSBL UTILITY II�� 15 1 COVFRED EASEMENT N BSBL 30' 16' PAjTl0 I I 1 .01 ' ROW Y_ BUILDING EAVE (TYP) T -- — -- PRIVATE I i�� --------- ,SEWER I t i l -- EASEMENT I �--- _- STORM DRAINAGE EASEMENT J� ' � ___---- P REG NO 20207�750482 70� 3O, S J PARCEL C , I i I I II I 11 1 1 PARCEL D I LOr 11 1 I i i I -------------- I I �\ 00467400001\100 i TYPE OF AREA SQUARE FOOTAGE STORMWATER FACILITY LAWN AND LANDSCAPE 3,080 SF SOIL AMENDMENTS T5.13 ROOFS 4,710 SF R— TANK DETENTION SYSTEM HARD SURFACES 5,900 SF R— TANK DETENTION SYSTEM INCLUDES 2,170 OFFS17E ROW 259 RETROFIT ONS/TE IMPERVIOUS ROOF' 4,710 SF DRI VEWA Y 3,230 SF SIDEWALK & PA 7/0. 500 SF ONSI TE TOTAL: 8,440 SF OFFSITE IMPERVIOUS ROAD. 570 SF SIDEWALK 500 SF NET 82ND PL W RUN—ON 1,100 SF ROAD. 2,170 SF FOUND REBAR W/CAP I I STAMPED "LSA 22_q69"-\\ 0.1 '(W) OF CORNER 0046740000120/' i PROJECT CLASSIFICATION PROJECT CLASSIFICA TION. — CA TEGORY 2 EDMONDS WA TER SHED: — GOOD HOPE POND FLOW CONTROL STANDARD: — DETENTION VAULT STORMWA TER BMPS. — POST CONSTRUCTION SOIL AMENDMENT (T5.13) 1 SP #2 2007-57 #20100�7275002 I I 2 II I I I I I jl I SP #2 2007-58 l I #201007275001 I 1 I 1 I II I I J I 00467400002701 I � I EXISTING FIRE HYDRANT �I II II _-i I 00467400002600 �I 30 _ I � I I / 00467400002500 I / I / I/ I� 1I I1� I I I I I I I I I I I I I I I I I I I I I GRADING QUANTITIES 2 ZNl 2 2007H ST SW 2 ND ST SW 203RD ST SW 2 Ja 0 7H ST 3 g 29 :k Q MAIN ST z `n° 212774 KqY ro J 3 218 S7 SW 00 J 208TH ST SW 21 TH ST W ST SW 99 �h VICINITY MAP NOT TO SCALE N SCALE.- 1 " = 20' 0 10 20 40 PROJECT TEAM OWNER / APPL/CANT SELECT HOMES 16531 13TH AVENUE W. #A 107 LYNNWOOD, WASHINGTON 98037 (425) 742-6044 EMAIL: KAYLA.CLARK@OUTLOOK.COM CONTACT.- KAYLA CLARK SURVEYOR PACIFIC COAST SURVEYS, INC. PO BOX 13619 MILL CREEK, WA 98082 (425) 512-7099 CONTACT.- DARREN J. RIDDLE SITE DATA CIVIL ENGINEER RAM ENGINEERING INC. 16531 13TH A VE W, SUI TE A 108 LYNNWOOD, WA 98037 (425) 678-6960 EMAIL: ROBL@RAMENGINEERINGINC.COM CONTACT.- ROB L. LONG, PE SITE ADDRESS: 21222 82ND PL W, EDMONDS, WA 98026 PARCEL NUMBER: 00467400000600 TOTAL SITE AREA: 11,520 SF (0.26 AC) EXISTING ZONING: RM-2.4 MINIMUM LOT AREA: 2,400 SF PER DU AGENCIES/UTILITIES JURISDICTION CITY OF EDMONDS WATER DISTRICT CITY OF EDMONDS SEWER DISTRICT CITY OF EDMONDS STORM WA TER CITY OF EDMONDS SCHOOL DISTRICT EDMONDS SCHOOL DISTRICT NO. 15 FIRE DISTRICT SNOHOMISH COUNTY FIRE DISTRICT NO. 1 TELEPHONE FRONTIER COMMUNICATIONS ELECTRICAL SNOHOMISH COUNTY PUD NO. 1 GAS PSE GARBAGE REPUBLIC SERVICE SHEET INDEX 1 CV-01 COVER SHEET / SITE DEVELOPMENT PLAN _ 2 GN-01 GENERAL NOTES & LEGEND 3 EC-01 EXISTING CONDITIONS MAP 4 TP-01 CLEARING, GRADING & TESC PLAN 5 TD-01 GRADING & TESC NOTES & DETAILS 6 RS-01 ROAD & UTILITY PLAN 7 RP-01 ROAD & STORM DRAINAGE PROFILES 8 VT-01 R-TANK DETENTION SYSTEM PLAN 9 VT-02 R-TANK DETENTION SYSTEM DETAILS 10 VT-03 R-TANK DETENTION SYSTEM DETAILS 11 TC-01 TRAFFIC CONTROL PLAN 12 DT-01 STANDARD DETAILS 13 DT-02 STANDARD DETAILS 14 DT-03 STANDARD DETAILS CUT ±800 CU YDS FILL: t 100 CU YDS 1) GRADING QUANTITIES INCLUDE ADDITIONAL CUT AND FILL QUANTITIES POTENTIALLY NEEDED FOR ORGANIC SOIL AMENDMENTS IN ACCORDANCE WITH BMP T5.13 POST CONSTRUCTION SOILS QUALITY AND DEPTH. 2) GRADING QUANTITIES HAVE BEEN ESTIMATED AS SHOWN ABOVE. SITE IMPORT AND EXPORT IS BELOW 10, 000 CY AND THUS NO HAUL ROUTE AGREEMENT IS REQUIRED. Know what% below, Call bef are you dig. RAM ENGINEERING, INC. Civil Engineering / Land Planning 16531 13TH AVE W, SUITE A108 LYNNWOOD, WA 98037 PHONE: (425) 678-6960 WWW.RAMENGINEERINGINC.COM Z Oftft o W 2 2 oc 0 � 0 U W ~ 2 U i o cl: � -_j W Q � ti a o Q) �0© PLN2020-0029 ENGINEER: Q W 0 LOT 1: LOT 2. 21228 21226 82ND 82ND PL PL W W (BLD2020-0687) (BLD2020— 0689) ROB L. LONG, PE DRAWN B Y.- LOT J. 21224 82ND PL W (BLD2020-0688) BR/AN CLARK LOT 4: 21222 82ND PL W (BLD2020-0690) ISSUE DATE SCALE 412112020 1 AS NOTED CITY OF EDMONDS JOB NO. 20-003 DATE: SHEET.- CV-01 BY - CITY ENGINEERING DIVISION T ' OF 14 SH GENERAL NOTES 1. ALL MATERIALS AND WORK SHOWN ON THESE PLANS SHALL CONFORM TO THE CITY OF EDMONDS STANDARD PLANS AND DETAILS, THE FOLLOWING SPECIFICATIONS AND CODES, AND ALL OTHER APPLICABLE LOCAL MUNICIPAL, STATE, AND FEDERAL CODES, RULES AND REGULATIONS- - CURRENT INTERNATIONAL BUILDING CODE (IBC) - 2021 WSDOT/APWA STANDARD SPECIFICATIONS FOR ROAD, BRIDGE AND MUNICIPAL CONSTRUCTION - 201212014 WASHINGTON STATE DEPARTMENT OF ECOLOGY STORMWA TER MANAGEMENT MANUAL FOR WESTERN WASHINGTON (AS AMENDED IN DECEMBER 2014) 2. STANDARD PLAN AND TYPE NUMBERS INDICATED ON THESE DRAWINGS REFER TO CITY OF EDMONDS STANDARD DETAILS, UNLESS NOTED OTHERWISE J. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOBSITE WHENEVER CONSTRUCTION IS IN PROGRESS. 4. DEVIATIONS FROM THESE PLANS MUST BE APPROVED BY THE ENGINEER OF RECORD AND THE LOCAL GOVERNING AUTHORITY. 5. CONTRACTOR SHALL RECORD ALL APPROVED DEVIATIONS FROM THESE PLANS ON A SET OF 'AS -BUILT" DRAWINGS AND SHALL SUMMARIZE ALL ASBUILT CONDITIONS ON ONE SET OF REPRODUCIBLE DRAWINGS FOR SUBMITTAL TO THE OWNER PRIOR PROJECT COMPLETION AND ACCEPTANCE. A SET OF AS -BUILT DRAWINGS SHALL BE SUBMITTED TO THE CITY OF EDMONDS PRIOR TO FINAL APPROVAL OF THE BUILDING OCCUPANCY/FINAL PROJECT APPROVAL. 6. ELEVATIONS SHOWN ARE IN FEET. SEE SURVEY FOR BENCHMARK INFORMATION. 7. THE LOCATIONS OF EXISTING UTILITIES AND SITE FEATURES SHOWN HEREON HAVE BEEN FURNISHED BY OTHERS BY FIELD SURVEY OR OBTAINED FROM AVAILABLE RECORDS AND SHOULD THEREFORE BE CONSIDERED APPROXIMATE ONLY AND NOT NECESSARILY COMPLETE. I T IS THE SOLE RESPONSIBILITY OF THE CON TRA C TOR TO INDEPENDENTLY VERIFY THE ACCURACY OF ALL U TILI TY L OCA TIONS SHOWN AND TO FURTHER DISCOVER AND PROTECT A N Y OTHER UTILITIES NOT SHOWN HEREON WHICH MAY BE AFFECTED BY THE IMPLEMENTATION OF THIS PLAN. CONTRACTOR SHALL VERIFY LOCATION, DEPTH, SIZE, TYPE AND CONDITION OF EXISTING UTILITY LINES AT CONNECTION OR CROSSING POINTS BEFORE TRENCHING FOR NEW UTILITIES. ENGINEER ASSUMES NO RESPONSIBILITY FOR THE COMPLETENESS OR ACCURACY OF THE EXISTING UTILITIES AND SITE FEATURES PRESENTED ON THESE DRAWINGS. ENGINEER SHALL BE NOTIFIED IMMEDIATELY OF CONFLICTS THAT ARISE. 8. CONTRACTOR SHALL LOCATE AND PROTECT ALL UTILITIES DURING CONSTRUCTION AND SHALL CONTACT THE UNDERGROUND UTILITIES LOCATION SERVICE (1-800-424-5555) AT LEAST 48 HOURS PRIOR TO CONSTRUCTION. 9. CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AT THE PROJECT SITE BEFORE STARTING WORK AND SHALL NOTIFY OWNER'S REPRESENTATIVE OF ANY DISCREPANCIES. 10. PIPE LENGTHS WHERE SHOWN ARE APPROXIMATE AND MAY CHANGE DUE TO FIELD CONDITIONS. 11. CONTRACTOR SHALL OBTAIN A COPY OF THE GEOTECHNICAL REPORT (WHERE APPLICABLE) AND SHALL THOROUGHLY FAMILIARIZE HIMSELF WITH THE CONTENTS THEREOF. ALL SITE WORK SHALL BE PERFORMED IN STRICT COMPLIANCE WITH THE RECOMMENDATIONS OF THIS REPORT. 12. STRUCTURAL FILL MATERIAL AND PLACEMENT SHALL CONFORM TO THE RECOMMENDATIONS OF THE PROJECT GEOTECHNICAL REPORT. 13. SUBGRADE SOILS IN ALL AREAS WHERE RAIN GARDENS, INFILTRATION OR PERVIOUS PAVEMENT IS TO BE PLACED SHALL BE DELINEATED AND PROTECTED AT ALL TIMES FROM COMPACTIVE ACTIVITIES (I.E. HEAVY EQUIPMENT, STOCKPILING). 14. MANHOLES, CATCH BASINS, UTILITIES AND PAVEMENT SHALL BEAR ON MEDIUM DENSE TO VERY DENSE NATIVE SOIL OR COMPACTED STRUCTURAL FILL. IF SOIL /S DISTURBED, SOFT, LOOSE, WET OR IF ORGANIC MATERIAL /S PRESENT AT SUBGRADE ELEVATION, REMOVE AND REPLACE WITH COMPACTED STRUCTURAL FILL PER GEOTECHNICAL REPORT. 15. SEE SURVEY AND ARCHITECTURAL DRAWINGS FOR DIMENSIONS AND LOCATIONS OF BUILDINGS, LANDSCAPED AREAS AND OTHER PROPOSED OR EXISTING SITE FEATURES. 16. SEE ARCHITECTURAL DRAWINGS FOR PERIMETER FOUNDATION DRAINS. FOUNDATION DRAINS SHALL BE INDEPENDENT OF OTHER SITE DRAIN LINES AND SHALL BE TIGHTLINED TO THE STORM DRAIN SYSTEM WHERE INDICATED ON THE PLANS. 17. ALL REQUIRED STORMWA TER FACILITIES MUST BE CONSTRUCTED AND IN OPERATION PRIOR TO INSTALLATION OF ANY PAVEMENT UNLESS OTHERWISE APPROVED BY THE ENGINEER. 18. ALL ROOF DRAINS, CATCH BASINS AND OTHER EXTERNAL DRAINS SHALL BE CONNECTED TO THE STORM DRAINAGE SYSTEM, UNLESS NOTED OTHERWISE. 19. ALL FOOTING DRAINS SERVING BUILDINGS, WALLS, ROCKERIES, ETC. SHALL CONNECT TO THE DRAINAGE SYSTEM OR INDIVIDUAL DRYWELLS. 20. CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS REQUIRED FOR INSTALLATION OF ALL SITE IMPROVEMENTS INDICATED ON THESE DRAWINGS. 21. A SEPARATE IRRIGATION PERMIT MUST BE OBTAINED FROM THE CITY PUBLIC WORKS DEPARTMENT. PRIOR TO FINAL CONSTRUCTION ACCEPTANCE, PROVIDE TO THE CITY WATER QUALITY TECHNICIAN, A COPY OF THE BACKFLOW TEST REPORT. TEST REPORTS CAN BE FAXED TO 425-744-6057 OR EMAILED TO JEFF.KOBYLK@EDMONDSWA.GOV. BACKFLOW TESTING SHALL BE COMPLETED BY THE OWNER ANNUALLY THEREAFTER. 22. AS A MINIMUM REQUIREMENT, ALL DISTURBED AREAS ON AND OFF SITE SHALL BE RETURNED TO THE EQUIVALENT OF THEIR PRECONSTRUCT/ON CONDITION IN ACCORDANCE WITH APPROPRIATE REQUIREMENTS AND STANDARDS. 23. ALL DISTURBED SOIL AREAS SHALL BE COMPOST AMENDED AND SEEDED OR STABILIZED BY OTHER ACCEPTABLE METHODS FOR THE PREVENTION OF ONSITE EROSION AFTER THE COMPLETION OF CONSTRUCTION. SEE EROSION CONTROL PLANS FOR SPECIFIC GRADING AND EROSION CONTROL REQUIREMENTS. 24. THE CONTRACTOR SHALL KEEP OFF -SITE STREETS CLEAN AT ALL TIMES BY SWEEPING. WASHING OF THESE STREETS WILL NOT BE ALLOWED WITHOUT PRIOR APPROVAL. 25. THIS PROJECT IS NOT A BALANCED EARTHWORK PROJECT. BOTH EXPORT AND IMPORT OF SOIL AND ROCK MATERIALS ARE REQUIRED. 26. SLOPE OF FINISHED GRADE SHALL BE CONSTANT BETWEEN FINISHED CONTOURS OR SPOT ELEVATIONS SHOWN. 27. FINISHED GRADE SHALL SLOPE AWAY FROM BUILDING WALLS AT MINIMUM 59 SLOPE FOR A MINIMUM DISTANCE OF 10 FEET. 28. CONTRACTOR SHALL BE RESPONSIBLE FOR AND SHALL INSTALL AND MAINTAIN SHORING AND BRACING AS NECESSARY TO PROTECT WORKERS, EXISTING BUILDINGS, STREETS, WALKWAYS, UTILITIES AND OTHER EXISTING AND PROPOSED IMPROVEMENTS AND EXCAVATIONS AGAINST LOSS OF GROUND OR CAVING EMBANKMENTS. CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR REMOVAL OF SHORING AND BRACING, AS REQUIRED. 29. CONTRACTOR SHALL OBTAIN APPROVAL FROM THE CITY AND FOLLOW CITY PROCEDURES FOR ALL WATER SERVICE INTERRUPTIONS, HYDRANT SHUTOFFS, STREET CLOSURES OR OTHER ACCESS RES TRIC TIONS. CON TRA C TOR SHALL NOT REL OCA TE OR ELIMINATE ANY HYDRANTS WI THOU T FIRST OBTAINING WRITTEN APPROVAL FROM THE FIRE MARSHAL. 30. COORDINATE AND ARRANGE FOR ALL UTILITY CONNECTIONS, UTILITY RELOCATIONS AND/OR SERVICE INTERRUPTIONS WITH THE AFFECTED OWNERS AND APPROPRIATE UTILITY COMPANIES. CONNECTIONS TO EXISTING UTILITIES SHALL BE MADE ONLY WITH ADVANCE WRITTEN APPROVAL OF THE AUTHORITIES GOVERNING SAID UTILITIES. 31. ALL UTILITIES SHALL BE PLACED UNDERGROUND. 32. EXISTING UTILITY LINES /N SERVICE WHICH ARE DAMAGED DUE TO CONSTRUCTION WORK SHALL BE REPAIRED AT CONTRACTOR'S EXPENSE AND INSPECTED AND ACCEPTED BY CITY OF EDMONDS AND OWNERS REPRESENTATIVE PRIOR TO BACKFILLING. 33. NEW UTILITY LOCATIONS ARE GENERALLY SHOWN BY DIMENSION, WHERE NO DIMENSIONS ARE INDICATED, LOCATIONS MAY BE SCALED FROM DRAWINGS. FIELD ADJUSTMENTS SHALL BE APPROVED BY OWNER'S REPRESENTATIVE AND CITY. 34. FIELD STAKE ALL UTILITY STUBS AT THE PROPERTY LINE. 35. TRENCH BACKFILL OF UTILITIES LOCATED WITHIN THE CITY RIGHT-OF-WAY SHALL BE COMPACTED TO 959: COMPACTION TEST REPORTS SHALL BE PROVIDED TO THE CITY PRIOR TO PAVING. 36. WHERE NEW PIPE CLEARS AN EXISTING OR NEW UTILITY BY 6" OR LESS, PLACE POLYETHYLENE PLASTIC FOAM AS A CUSHION BETWEEN THE UTILITIES. 37. SEE MECHANICAL DRAWINGS (WHERE APPLICABLE) FOR CONTINUATION OF SITE UTILITIES WITHIN THE BUILDING. 38. SEE ELECTRICAL DRAWINGS (WHERE APPLICABLE) FOR EXTERIOR ELECTRICAL WORK. 39. SEE LANDSCAPE DRAWINGS (WHERE APPLICABLE) FOR SITE IRRIGATION SYSTEM. 40. PIPE MATERIAL AND S/GNAGE SUBMITTALS SHALL BE PROVIDED TO CITY ENGINEERING DIVISION FOR APPROVAL PRIOR TO INSTALLATION. NE 1/4, SEC 30, TWP 27N, RGE 4E, W.M. TESC NOTES 1. ESC MIN/MUM REQUIREMEN T- CONS TRUC T/ON ACCESS ROUT, CONS TRUC T/ON VEHICLE ACCESS SHALL BE, WHENEVER PRA C T/CAL, LIMITED TO ONE ROUTE. ACCESS POINTS SHALL BE STABILIZED WITH QUARRY SPALLS OR CRUSHED ROCK TO MINIMIZE THE TRACKING OF SEDIMENT ONTO PUBLIC ROADS. IF SEDIMENT IS TRANSPORTED ONTO A ROAD SURFACE, THE ROADS SHALL BE CLEANED THOROUGHLY AT THE END OF EACH DAY. SEDIMENT SHALL BE REMOVED FROM ROADS BY SHOVELING OR SWEEPING AND BE TRANSPORTED TO A CONTROLLED SEDIMENT DISPOSAL AREA WITHIN 24 HOURS. STREET WASHING SHALL BE ALLOWED ONLY AFTER SEDIMENT IS REMOVED IN THIS MANNER. 2. ESC MINIMUM REQUIREMENT -STABILIZATION OF EXPOSED AREAS. ALL SOILS EXPOSED BY LAND DISTURBING ACTIVITIES SHALL BE STABILIZED BY SUITABLE APPLICATION OF BMPS, INCLUDING, BUT NOT LIMITED, SOD, HYDROSEEDING, OR OTHER VEGETATION, PLASTIC COVERING, OR MULCHING. ALL BMPS SHALL BE SELECTED, DESIGNED, AND MAINTAINED IN ACCORDANCE WITH THE MANUAL. THE EXPOSED SOILS SHALL BE STABILIZED ACCORDING TO AN APPROVED TIMETABLE. (TYPICALLY, NO SOILS SHALL REMAIN EXPOSED FOR MORE THAN TWO DAYS FROM OCTOBER 1 THROUGH APRIL 30 AND NO MORE THAN SEVEN DAYS FROM MAY 1 THROUGH SEPTEMBER 30). J. ESC MINIMUM REQUIREMENT -PROTECTION OF ADJACENT PROPERTIES. ADJACENT PROPERTIES SHALL BE PROTECTED FROM SEDIMENT DEPOSITION BY APPROPRIATE USE OF VEGETATIVE BUFFER STRIPS, SEDIMENT BARRIERS OR FILTERS, DIKES OR MULCHING, OR BY A COMBINATION OF THESE MEASURES AND OTHER APPROPRIATE BMPS. 4. ESC MINIMUM REQUIREMENT- MAINTENANCE. ALL EROSION AND SEDIMENT CONTROL BMPS SHALL BE REGULARLY INSPECTED AND MAINTAINED BY THE OWNER TO ENSURE CONTINUED PERFORMANCE OF THEIR INTENDED FUNCTION. ALL MAINTENANCE AND REPAIR SHALL BE CONDUCTED /N ACCORDANCE WITH THE MANUAL. 5. ESC MINIMUM REQUIREMENT -OTHER BMPS. AS REQUIRED BY THE CITY, OTHER APPROPRIATE BMPS TO MITIGATE THE EFFECTS OF INCREASED RUNOFF SHALL BE APPLIED. 6. EROSION AND SEDIMENT CONTROL REQUIREMENT- UNDERGROUND UTILITY CONSTRUCTION. THE CONSTRUCTION OF UNDERGROUND UTILITY LINES SHALL SPECIFICALLY ADDRESS THE FOLLOWING: a. EROSION CONTROL FOR EXCAVATED AND STOCKPILED MATERIALS; b. THE PLACEMENT OF EXCAVATED MATERIAL WHERE CONSISTENT WITH SAFETY AND SPACE CONSIDERATIONS SHALL BE PLACED ON THE UPHILL SIDE OF TRENCHES; C. TRENCH DEWATERING SYSTEMS (MUST DISCHARGE INTO SEDIMENT TRAPS, SEDIMENT PONDS, OR OTHER ACCEPTABLE MEANS); d. TRACKING AND SPILLING OF MATERIALS ON STREETS DUE TO HAULING; e. DAILY CLEANUP AND STREET MAINTENANCE. 7. ADDITIONAL ESC MINIMUM REQUIREMENTS FOR LARGER DEVELOPMENTS. ALL NEW DEVELOPMENT AND REDEVELOPMENT THAT INCLUDED LAND DISTURBING ACTIVITIES OF GREATER THEN, OR EQUAL TO, ONE ACRE IN ADDITION TO MEETING THE MINIMUM REQUIREMENTS SET FORTH ABOVE SHALL COMPLY WITH ESC REQUIREMENTS LISTED BELOW. 8. ESC MINIMUM REQUIREMENT- DELINEATE CLEARING AND EASEMENT LIMITS. IN THE FIELD, MARK CLEARING LIMITS AND/OR ANY EASEMENTS, SETBACKS, SENSITIVE/CRITICAL AREAS AND THE BUFFERS, TREES AND DRAINAGE COURSES. 9. ESC MINIMUM REQUIREMENT -SEDIMENT TRAPPING. PRIOR TO LEAVING THE SITE, STORM WATER RUNOFF SHALL PASS THROUGH A SEDIMENT POND OR SEDIMENT TRAP, OR OTHER APPROPRIATE BMPS. SEDIMENT PONDS AND TRAPS, PERIMETER DIKES, SEDIMENT BARRIERS, AND OTHER BMPS INTENDED TO TRAP SEDIMENT ON -SITE SHALL BE CONSTRUCTED AS A FIRST STEP IN GRADING. THESE BMPS SHALL BE FUNCTIONAL BEFORE LAND DISTURBING ACTIVITIES TAKE PLACE. EARTHEN STRUCTURES, SUCH AS DAMS, DIKES, AND DIVERSIONS SHALL BE SEEDED AND MULCHED ACCORDING TO AN APPROVED TIMETABLE. 10. ESC MIN/MUM REQUIREMENT -CUT AND FILL SLOPES. CUT AND FILL SLOPES SHALL BE DESIGNED AND CONSTRUCTED /N A MANNER THAT WILL MINIMIZE EROSION. /N ADDITION, SLOPES SHALL BE STABILIZED IN ACCORDANCE WITH ESC REQUIREMENT NO. 2. 11. ESC MINIMUM REQUIREMENT -CONTROLLING OFF -SITE EROSION. PROPERTIES AND WATER WAYS DOWNSTREAM FROM DEVELOPMENT SITES SHALL BE PROTECTED FROM EROSION DUE TO INCREASES IN THE VOLUME, VELOCITY, AND PEAK FLOW RATE OF STORM WATER RUNOFF FROM THE PROJECT SITE. 12. ESC MINIMUM REQUIREMENT -STABILIZATION OF TEMPORARY CONVEYANCE CHANNELS AND OUTLETS. ALL TEMPORARY ON -SITE CONVEYANCE CHANNELS SHALL BE DESIGNED, CONSTRUCTED AND STABILIZED TO PREVENT EROSION FROM THE EXPECTED VELOCITY OF FLOW FROM A TWO-YEAR, 24-HOUR FREQUENCY STORM FOR THE DEVELOPED CONDITION. STABILIZATION ADEQUATE TO PREVENT EROSION OF OUTLETS, ADJACENT STREAM BANKS, SLOPES AND DOWNSTREAM REACHES SHALL BE PROVIDED AT THE OUTLETS OF ALL CONVEYANCE SYSTEMS. 13, ESC MINIMUM REQUIREMENT -STORM DRAIN INLET PROTECTION. ALL STORM DRAIN INLETS MADE OPERABLE DURING CONSTRUCTION SHALL BE PROTECTED SO THAT STORM WATER RUNOFF SHALL NOT ENTER THE CONVEYANCE SYSTEM WITHOUT FIRST BEING FILTERED OR OTHERWISE TREATED TO REMOVE SEDIMENT. 14. ESC MINIMUM REQUIREMENT -REMOVAL OF TEMPORARY BMPS. ALL TEMPORARY EROSION AND SEDIMENT CONTROL BMPS SHALL BE REMOVED WITHIN 30 DAYS AFTER FINAL SITE STABILIZATION IS ACHIEVED OR AFTER THE TEMPORARY BMPS ARE NO LONGER NEEDED. TRAPPED SEDIMENT SHALL BE REMOVED OR STABILIZED ON SITE. DISTURBED SOIL AREAS RESULTING FROM REMOVAL SHALL BE PERMANENTLY STABILIZED, 15. EROSION AND SEDIMENT CONTROL REQUIREMENT-DEWATERING CONSTRUCTION SITES. DEWATERING SYSTEMS SHALL DISCHARGE INTO A SEDIMENT TRAP OR SEDIMENT POND. 16. EROSION AND SEDIMENT CONTROL REQUIREMENT -CONTROL OF POLLUTANTS OTHER THAN SEDIMENT ON CONSTRUCTION SITES. ALL POLLUTANTS OTHER THAN SEDIMENT THA T OCCUR ON SITE DURING CONSTRUCT/ON SHALL BE HANDLED AND DISPOSED OF /N A MANNER THA T DOES NOT CAUSE CONTAM/NA T/ON OF STORM WA TER. 17, EROSION AND SEDIMENT CONTROL REQUIREMENT -FINANCIAL LIABILITY. PERFORMANCE BONDING, OR OTHER APPROPRIATE FINANCIAL INSTRUMENTS, SHALL BE REQUIRED FOR ALL PROJECTS TO ENSURE COMPLIANCE WITH THE APPROVED EROSION AND SEDIMENT CONTROL PLAN. [ORD. 3013 1, 1995]. TREE PROTECT/ON NOTES PRIOR TO DEVELOPMENT ACTIVITY OR INITIATING TREE REMOVAL ON THE SITE, VEGETATED AREAS AND INDIVIDUAL TREES TO BE PRESERVED, INCLUDING ANY STREET OR RIGHT-OF-WAY TREES, SHALL BE PROTECTED FROM POTENTIALLY DAMAGING ACTIVITIES PURSUANT TO THE FOLLOWING STANDARDS: A. PLACING MATERIALS NEAR TREES. NO PERSON MAY CONDUCT ANY ACTIVITY WITHIN THE PROTECTED AREA OF ANY TREE DESIGNATED TO REMAIN, INCLUDING, BUT NOT LIMITED TO, OPERATING OR PARKING EQUIPMENT, PLACING SOLVENTS, STORING BUILDING MATERIAL OR SOIL DEPOSITS, OR DUMPING CONCRETE WASHOUT OR OTHER CHEMICALS. DURING CONSTRUCTION, NO PERSON SHALL ATTACH ANY POTENTIALLY HARMFUL OBJECT TO ANY TREE DESIGNATED FOR PROTECTION. B. PROTECTIVE BARRIER. BEFORE DEVELOPMENT LAND CLEARING FILLING OR ANY LAND ALTERATION THE APPLICANT SHALL: a. ERECT AND MAINTAIN READILY VISIBLE TEMPORARY PROTECTIVE TREE FENCING ALONG THE LIMITS OF DISTURBANCE TO COMPLETELY SURROUND THE PROTECTED AREA OF ALL RETAINED TREES OR GROUPS OF TREES. FENCES SHOULD BE CONSTRUCTED OF CHAIN -LINK AND BE AT LEAST SIX (6) FEET HIGH, UNLESS OTHER TYPE OF FENCING IS AUTHORIZED BY THE CITY. b. WHEN REQUESTED BY THE CITY, INSTALL HIGHLY VISIBLE SIGNS SPACED NO FURTHER THAN 15 FEET ALONG THE ENTIRETY OF THE PROTECTIVE TREE FENCE. SAID SIGN MUST STATE AT A MINIMUM "TREE PROTECTION AREA, ENTRANCE PROHIBITED -AND PROVIDE THE CITY PHONE NUMBER FOR CODE ENFORCEMENT TO REPORT VIOLA TIONS. C. PROHIBIT EXCAVATION OR COMPACTION OF EARTH OR OTHER POTENTIALLY DAMAGING ACTIVITIES WITHIN THE BARRIERS; PROVIDED, THAT THE ADMINISTRATOR MAY ALLOW SUCH ACTIVITIES APPROVED BY THE CITY TREE PROTECTION PROFESSIONAL AND UNDER THE SUPERVISION OF A QUALIFIED TREE PROFESSIONAL RETAINED BY THE APPLICANT. d. MAINTAIN THE PROTECTIVE BARRIERS IN PLACE FOR THE DURATION OF THE PROJECT UNTIL THE CITY AUTHORIZES THEIR REMOVAL. e. ENSURE THAT ANY APPROVED LANDSCAPING DONE IN THE PROTECTED ZONE SUBSEQUENT TO THE REMOVAL OF THE BARRIERS SHALL BE ACCOMPLISHED WITH WALK -BEHIND MACHINERY OR HAND LABOR. f. IN ADDITION TO THE ABOVE, THE CITY MAY REQUIRE THE FOLLOWING: i) IF EQUIPMENT IS AUTHORIZED TO OPERATE WITHIN THE CRITICAL ROOT ZONE, COVER THE AREAS ADJOINING THE CRITICAL ROOT ZONE OF A TREE WITH MULCH TO A DEPTH OF AT LEAST SIX (6) INCHES OR WITH PLYWOOD OR SIMILAR MATERIAL IN ORDER TO PROTECT ROOTS FROM DAMAGE CAUSED BY HEAVY EQUIPMENT. ii) MINIMIZE ROOT DAMAGE BY EXCA VA TING A 2-FOOT-DEEP TRENCH, A T EDGE OF CRITICAL ROOT ZONE, TO CLEANL Y SEVER THE ROOTS OF TREES TO BE RETAINED. CORRECTIVE PRUNING PERFORMED ON PROTECTED TREES IN ORDER TO AVOID DAMAGE FROM MACHINERY OR BUILDING ACTIVITY. iv) MAINTENANCE OF TREES SHALL BE ACHIEVED BY THE APPLICANT THROUGHOUT THE CONSTRUCTION PERIOD BY WATERING AND FERTILIZING. C. GRADE. a. THE GRADE SHALL NOT BE ELEVATED OR REDUCED WITHIN THE CRITICAL ROOT ZONE OF TREES TO BE PRESERVED WITHOUT THE ADMINISTRATORS AUTHORIZATION BASED ON RECOMMENDATIONS FROM A QUALIFIED PROFESSIONAL. THE ADMINISTRATOR MAY ALLOW COVERAGE OF UP TO ONE-HALF (1/2) OF THE AREA OF THE TREES CRITICAL ROOT ZONE WITH LIGHT SOILS (NO CLAY) TO THE MINIMUM DEPTH NECESSARY TO CARRY OUT GRADING OR LANDSCAPING PLANS, IF I WILL NOT IMPERIL THE SURVIVAL OF THE TREE AERATION DEVICES MAY BE REQUIRED TO ENSURE THE TREES SURVIVAL. b. IF THE GRADE ADJACENT TO A PRESERVED TREE IS RAISED SUCH THAT IT COULD SLOUGH OR ERODE INTO THE TREES CRITICAL ROOT ZONE, IT SHALL BE PERMANENTLY STABILIZED TO PREVENT SUFFOCATION OF THE ROOTS. C. THE APPLICANT SHALL NOT INSTALL AN IMPERVIOUS SURFACE WITHIN THE CRITICAL ROOT ZONE OF ANY TREE TO BE RETAINED WITHOUT THE AUTHORIZATION OF THE ADMINISTRATOR. THE ADMINISTRATOR MAY REQUIRE SPECIFIC CONSTRUCTION METHODS AND/OR USE OF AERATION DEVICES TO ENSURE THE TREES SURVIVAL AND TO MINIMIZE THE POTENTIAL FOR ROOT -INDUCED DAMAGE TO THE IMPERVIOUS SURFACE. d. TO THE GREATEST EXTENT PRACTICAL, UTILITY TRENCHES SHALL BE LOCATED OUTSIDE OF THE CRITICAL ROOT ZONE OF TREES TO BE RETAINED. THE ADMINISTRATOR OR DIRECTOR MAY REQUIRE THAT UTILITIES BE TUNNELED UNDER THE ROOTS OF TREES TO BE RETAINED IF THE ADMINISTRATOR OR DIRECTOR DETERMINES THAT TRENCHING WOULD SIGNIFICANTLY REDUCE THE CHANCES OF THE TREES SURVIVAL. e. TREES AND OTHER VEGETATION TO BE RETAINED SHALL BE PROTECTED FROM EROSION AND SEDIMENTATION. CLEARING OPERATIONS SHALL BE CONDUCTED SO AS TO EXPOSE THE SMALLEST PRACTICAL AREA OF SOIL TO EROSION FOR THE LEAST POSSIBLE TIME. TO CONTROL EROSION, IT IS ENCOURAGED THAT SHRUBS, GROUND COVER AND STUMPS BE MAINTAINED ON THE INDIVIDUAL LOTS, WHERE FEASIBLE. D. DIRECTIONAL FELLING. DIRECTIONAL FELLING OF TREES SHALL BE USED TO AVOID DAMAGE TO TREES DESIGNATED FOR RETENTION AND TO AVOID DAMAGE TO PRIVATE AND PUBLIC INFRASTRUCTURE. E. ADDITIONAL REQUIREMENTS. THE ADMINISTRATOR MAY REQUIRE ADDITIONAL TREE PROTECTION MEASURES THAT ARE CONSISTENT WITH ACCEPTED URBAN FORESTRY INDUSTRY PRACTICES. LEGEND - PROPOSED UTILITIES / SURFACE FEATURES ------------- SAWCUT EASEMENT BUILDING FOOTPRINT - - - - - - - BUILDING SETBACK FENCE GUARDRAIL BARRICADE XXX PROPOSED CONTOUR RETAINING WALL ROCKERY MAILBOX JIL SIGN STREET LIGHT STORM DRAIN PIPE ------------- ROOF & FOOTING DRAIN DI TCH ■ TYPE I CB TYPE Il CB PIPE FLOW • STORM CLEANOUT O YARD DRAIN (10 OVERFLOW STRUCTURE SEWER MAIN SEWER SERVICE ----- WATER MAIN 0 SEWER MANHOLE PIPE FLOW • SEWER CLEANOUT FIRE DEPT CONNECTION WATER METER o- IRRIGATION METER Ak FIRE HYDRANT AIR RELEASE VALVE •� BLOW OFF ] H [ GATE VALVE ]I[ TEE W/ BLOCKING ,. [ BEND W/ BLOCKING RESTRAINED JOINT ]►[ REDUCER ]� SLEEVE COUPLING DETECTOR CHECK VAL VE o POST INDICATOR VALVE (PI V) ROCK CHECK DAM ■ TEMPORARY CB, TYPE I 0 TEMPORARY CB, TYPE H PIPE FLOW TEMPORARY STAND PIPE OCB PROTECTION CONSTRUCTION ENTRANCE FILTER FENCE CONSTRUCTION FENCE LIMITS OF CLEARING INTERCEPTOR SWALE INTERCEPTOR CULVERT SLOPE DAGGER `b RIPRAP PAD BERM ❑ GRA VEL ❑ ASPHALT PAVEMENT SIDEWALK LEGEND - EXISTING UTILITIES / FEATURES X WIRE FENCE EX REBAR o CHAIN LINK FENCE ❑- WOOD FENCE SECTION = DITCH OR SWALE 1--� QUARTER SECTION n n n n GUARDRAIL ® EX MONUMENT RETAINING WALL ROCKERY ASPHAL T -------FLOW - - - - - - - CURB ❑ CONCRETE -- - - - - - ASPHALT - - - - - - - CONCRETE ❑ GRA VEL -------GRAVEL ------------ ROOF WETLAND CHANNEL/ZA T/ON DRIP LINE ❑ CATCH BASIN, TYPE I - - - - - - - SURFACE FEATURES O CATCH BASIN, TYPE H LILILIL�/1/1/� BUILDING FOOTPRINT Q SD PIPE FLOW --------- TOP OF 40Z SLOPE Qo YARD DRAIN - - - - - STEEP SLOPE BUFFER o STORM CLEANOUT - - EDGE OF WETLAND WETLAND BUFFER STORM CULVERT END - - -190- - - 10' CONTOUR SEWER MANHOLE ------ 192------ o SEWER CLEANOUT ----SD- STORM DRAIN PIPE Q ----SS- SEWER MAIN SS PIPE FLOW ----FM- SEWER FORCE MAIN ® SEPTIC LID ----W- WATER MAIN FIRE HYDRANT OHP AERIAL POWER LINE E&- WATER METER P BURIED POWER LINE ----G- GAS MAIN m GATE VALVE C BURIED CABLE WATER MANHOLE - -TV- BURIED TV AIR/VAC RELEASE VALVE T- BURIED TELEPHONE LINE C>-- BLOW OFF - - -P/T BURIED POWER/TELEPHONE ® IRRIGATION METER TO BURIED FIBER OPTIC CABLE X IRRIGATION VALVE Know what% below, Call bef are you dig. -& POWER POLE E-- GUY ANCHOR STREET LIGHT POLE LIGHT © POWER VAULT E TRANSFORMER ,@( POWER METER Z JUNCTION BOX ❑O GAS METER GAS VALVE OF FIBER OPTICS MANHOLE e TV RISER TELECOMM VAULT ❑ TELECOMM RISER TELECOMM JUNCTION BOX Ej__�::::- TRAFFIC SIGNAL o MAIL BOX SIGN o BOLLARD • SOIL LOG TEST PIT CONIFEROUS TREE 0 DECIDUOUS TREE CONIFEROUS TREE TO BE SA VED DECIDUOUS TREE 0 TO BE SA VED LOT 1: 21228 82ND PL W (BLD2020-0687) LOT 2. 21226 82ND PL W (BLD2020-0689) LOT J. 21224 82ND PL W (BLD2020-0688) LOT 4: 21222 82ND PL W (BLD2020-0690) APPROVED FOR CONSTRUCTION CITY OF EDMONDS DATE: BY - CITY ENGINEERING DIVISION RAM ENGINEERING, INC. Civil Engineering / Land Planning 16531 13TH AVE W, SUITE A108 LYNNWOOD, WA 98037 PHONE: (425) 678-6960 WWW.RAMENGINEERINGINC.COM �- I =© X (4 Q W LU 0 �o fv W s� l0 d 38608 A;Z \� EGISTEg��� IONe 1. ENGINEER: ROB L. LONG, PE DRAWN B Y.- BR/AN CLARK ISSUE DATE: SCALE: 412112020 AS NOTED JOB NO: 20-003 SHEET: GN-01 SHT 2 OF 14 F = 11 MY SISTERS PLACE LLC 8304 2127H ST SW EDMONDS, WA 98026 00467400000300 0 7 '1 I I I 1 I I I I I CALVARY CHAPEL ED/ v I L MN NON-PROFIT W EDMONDS, WA 98026 I j 00467400000601 L� <??\ 16.9' /r�TT�;T�I i I, �HEDLai 111/�/�/1111�J 1 6.8' I % I i i 15.6' ��7TTTTTT/T/7� 1 20 SHED I� LL/L1/1111L1LJ 15.5' I RM-2,4 12"x2 D I I I x ' NE 1/4, SEC 30, TWP 27N, RGE 4E, W.M. N 89 06'47" W 488.01 ' _ _ _ _ _ 2 / 2T/7 S T SW FOUND CASED CONC. MON. W/ 1-1/2" BRASS DISK & 'X" DOWN 0.15'. VISITED 5-20-19. co U Z ED ED I_ I I ��z,� I I I I I � \ *_ �-- I I I I r 0.5'l-4 - X WOOD FENCE \ I \I I I I I I I I I I WOOD F x ENCE 0 5 I I I I I>7 \ 0.4' I I I I II I SP #2-2007-58 \\ I I I l I #201007275001 X RM-2,4 CONCRETE /ice —� Q I I II I I RM-2 4 — — — CAIN BENJAMIN T & BARBARA J 21214 82ND PL WDCRAM ANGELA Ad ETAIL A EDMONDS, WA 98026 I / i I � I I J I 21219 82ND PL W 00467400000500 / ��\ I i Y I I 2 I I N I EDMONDS, WA 98026 NOT TO SCALE l i I vo o I p I I I I 00467400002701 I I �____——\\ \ / I FOUND REBAR I SEE DETAIL/A \ / i III IW/CAP STAMPED I II I 'LSA 22969" T CORNER I I I I 1-- X---X_--X WOOD FENCE _ �I I -- -- -- x-- -- --N 89V64-7- - Wx --128, 0,1' — x L — — — - -- --�-- I CB RIM=417.95 I L — 1E 12" CPP(N)=415.35 11E 12" RCP(S)=415.35 I CONCRETE x ,-\ I I it W I 7- — — — — — — — — — i — — — — — — J / J AI � - I I �\ I '--- L1/1/�/1111L1/1/1/1/1/11L/L�j o I I I A HOUSEcn— ,, � ►, 1-., I I I I I I GRAVEL � N 04 I o II i I Lc)3 I `� I RM-2,4 P 00467400000600 HOFFMAN DELORIS E 82ND PL W EDMONDS,WA 98026 i1Es — W — W I 00467400002600 \ I I o I 5�» F I I--------- Q) I EC I % 48" F I 1 I � 6" DEC I I I I f I I o.s'--ss----ss--- SS-- — � i �\\ WOOD FENCE i SS— — — --L SS I SS— — — -I— CO I I I CB SS RIM=418.93 I \�� 26" F ?sr, I I I I 1E 12" RCP(N)=415.63 I I 1E 12" RCP(S)=415.63 I j I I I I 1E 12" RCP(SW)=416.33 -- 28" F N 89 "06'47" W 128.01-- -- _--- -- ' S° �. I S� 28"x2 F i I / I 3: I I I ' STORM DRAINAGE EASEMENT I I I I o PER REC NO 202010150482 I` I I�\ ,�\ I L ' I 4 `� I C VERT 10' % ---- I I I �V I 1E 12" RCP-417.55 RS-8 ; I I I ,' I I I RS-8 I I I / J I I SHEPPERD PETER W I I \ I I 21313 82ND PL W HAWARDEN TRACTS rEDMONDS, WA 98026 VOL, 14, PAGE 69 PARCEL C I I I I 00467400002500 /,�,' I `�I\ II T ALVARY CHAPEL EDMONDS/LYIGNWOOD 21328 82ND PL W jEDMONDS, WA 9802d i 00467400001100 I 00467400001100 FOUND REBAR W/CAP I STAMPED "LSA 22969" 0.1 '(W) OF CORNER I 00467400001200 I I N 89 06'47" W 381.55' (BASIS OF BEARING) THE LOCATION OF UNDERGROUND UTILITIES SHOWN HEREON IS APPROXIMATE ONLY. THIS SURVEY DOES NOT PURPORT TO SHOW THE LOCATION OF ALL UTILITIES. THE OWNER SHOULD CONTACT THE PURVEYORS OF ALL UTILITIES /N THE AREA TO DETERMINE THE LOCATION AND DEPTH OF ALL UTILITIES ON AND ADJACENT TO THE PROPERTY. FOUND CASED CONC. MON. W/ 1-1/2" BRASS DISK & "X". DOWN 0.25'. VISITED 5-20-19. SCALE: I" = 10' 0 5 10 20 LEGAL DESCRIPTION ABBREV/A TED LEGAL: HAWARDEN TRACTS BLK 000 D-00 - LOT 6 EXC W 15OFT THOF BASIS OF BEARINGS THE MONUMENTED CENTERLINE OF 212TH ST. S W., AS THE BEARING OF N 89 0647" W. BENCH MARK FOUND REBAR W/CAP STAMPED "LSA 22969" DUE SOUTH OF THE SOUTHEAST PROPERTY CORNER. (PER GPS OBSERVATIONS) ELEVATION: 421.45' DATUM : NA VD 88 LEGEND - EXISTING UTILITIES / FEATURES /111LIZZ1-Z Z BUILDING FOOTPRINT - — —190- 10' CONTOURS ------192--- 2' CONTOURS ----SD— STORM DRAIN PIPE ----SS— SEWER MAIN ----FM— SEWER FORCE MAIN ----W— WATER MAIN — — — OHP AERIAL POWER LINE P BURIED POWER LINE ----G— GAS MAIN C BURIED CABLE TV BURIED TV T BURIED TELEPHONE LINE — — — P /T BURIED POWER/TELEPHONE FO BURIED FIBER OPTIC CABLE ❑ CATCH BASIN, TYPE I ❑@ CATCH BASIN, TYPE ll Q SD PIPE FLOW Qo YARD DRAIN O STORM CLEANOUT STORM CULVERT END O SEWER MANHOLE o SEWER CLEANOUT Q SS PIPE FLOW R FIRE HYDRANT EB--- WATER METER m GATE VALVE -0- POWER POLE E— GUY ANCHOR STREET LIGHT © POWER VAULT ❑O GAS METER GAS VALVE o MAIL BOX SIGN CONIFEROUS TREE 0 DECIDUOUS TREE Knave what's below. Call before you dig. I ;j 4 y no-?TOMro-?A LOT 1: 21228 82ND PL W (BLD2020-0687) L 0 T 2. 21226 82ND PL W (BLD2020— 0689) LOT J. 21224 82ND PL W (BLD2020-0688) LOT 4. 21222 82ND PL W (BLD2020-0690) APPROVED FOR CONSTRUCTION CITY OF EDMONDS DATE: BY- CITY ENGINEERING DIVISION P%AM ENGINEERING, INC. Civil Engineering / Land Planning 16531 13TH AVE W, SUITE A108 LYNNWOOD, WA 98037 PHONE: (425) 678-6960 WWW.RAMENGINEERINGINC.COM 0 U W a z z � g O R p U W ~ 2 U J 0 J O it Q 0 -0© 0 Z C4 �o ASx O 38508 w \NOIVAI. ENGINEER. 111111=0 ROB L. LONG, PE DRAWN BY.• BRIAN CLARK ISSUE DATE.SCALE.• 412112020 AS NOTED JOB NO. 20-003 SHEET EC-01 SHT 3 OF 14 NE 1/4, SEC 30, TWP 27N, RGE 4E, W.M. I I CONCRETE i � I / CLEARING LIMITS (TYP) -- < II FIL TER FABRIC FENCE m IPER COE STD D7L ER-90a-------------- cNj7jrT Tn—nl , E x X— ----------- HA WA RDEN TRACTS VOL. 14, PAGE 69 i SP #2 2007-58 #201007275001 1 TEMPORARY SEDIMENT TRAP FOR CA TCH BASINS (TYP) PER COE STD DTL ER-902, SHEET TD-01 /RIM= 41 Z 95 lE 12" CPP(N)=415.35 lE 12" RCP(S)=415.35 I )= 415.63 )=415.63 W)=416.33 nk SCALE. 1" = 10' 0 5 10 20 GRADING QUANTITIES CUT ±800 CU YDS FILL: f 100 CU YDS 1) GRADING QUANTITIES INCLUDE ADDITIONAL CUT AND FILL QUANTITIES POTENTIALLY NEEDED FOR ORGANIC SOIL AMENDMENTS IN ACCORDANCE WITH BMP T5.13 POST CONSTRUCTION SOILS QUALITY AND DEPTH. 2) GRADING QUAN71 TIES HAVE BEEN ES7IMA 7ED AS SHOWN ABOVE. S17E IMPORT AND EXPORT IS BELOW 10,000 CY AND THUS NO HAUL ROUTE AGREEMENT IS REQUIRED. SOILS NOTE I ALL DISTURBED SOILS WILL BE COMPOST AMENDED PER BMP T.5.13. TESC NOTE INSTALL AND MAINTAIN ALL TESC MEASURES ACCORDING TO APPROVED PLANS, EDMONDS STANDARD DETAILS, AND THE SWPPP. CONTRACTOR IS RESPONSIBLE FOR MAINTENANCE AND ADJUSTMENTS TO TESC MEASURES AS NEEDED. CB INLET PROTECTION NOTE CATCH BASIN INLET PROTECTION SHALL BE INSERTED AND MAINTAINED ON ALL NEWLY CONSTRUCTED CATCH BASINS 774ROUGHOUT 7HE SITE IMMEDIA TEL Y AF7ER INSTALLA RON. INSTALL PER COE STD D7L ER-902 ON SHT 7D-01 FIL TER FABRIC FENCE NOTE ADDITIONAL FIL TER FABRIC FENCING SHALL BE ADDED AS NEEDED. FENCING TO BE INSTALLED PER CITY OF EDMONDS STD DETAIL ER-900 (SEE DETAIL ON SHEET 7D-01). STOCKPILE NOTE STOCKPILE SHALL TO STABILIZED BY PLASTIC COVERING. THE EXPOSED SOILS SHALL BE STABILIZED ACCORDING TO AN APPROVED TIMETABLE. (TYPICALLY, NO SOILS SHALL REMAIN EXPOSED FOR MORE THAN TWO DAYS FROM OCTOBER 1 THROUGH APRIL 30 AND NO MORE THAN SEVEN DAYS FROM MAY 1 THROUGH SEPTEMBER 30). CONSTRUCTION SEQUENCE 1. SCHEDULE A PRE —CONSTRUCTION MEETING WITH CITY ENGINEERING DIVISION AT 425-771-0220, EXT. 1326. TWO DAY (48 HR) NOTICE IS REQUIRED. 2. REVIEW TEMPORARY EROSION AND SEDIMENT CONTROL NOTES. J. CALL FOR UTILITY LOCATES. 4. INSTALL TESC MEASURES AND MAINTAIN DUST CONTROL WHILE PREVENTING DISTURBANCE OF ANY AREAS OF VEGETATION OUTSIDE THE CONSTRUCTION ZONE. 5. HAVE EROSION CONTROL MEASURES INSPECTED BY CITY OF EDMONDS CITY ENGINEERING INSPECTOR. ALL TEMPORARY SEDIMENTATION AND EROSION CONTROL MEASURES MUST BE IN PLACE AND INSPECTED PRIOR TO ANY CONSTRUCTION OR SITE CLEARING. EROSION AND SEDIMENTATION CONTROL PRACTICES AND/OR DEVICES SHALL BE MAINTAINED UNTIL PERMANENT VEGETATION IS ESTABLISHED. 6. DEMOLISH EXISTING STRUCTURES. 7. ROUGH GRADE SITE AS REQUIRED TO INSTALL DRAINAGE FEATURES. 8. CLEAR, GRUB & ROUGH GRADE SITE. REVEGETATE DISTURBED AREAS NOT SUBJECT TO ADDITIONAL SURFACE DISTURBANCE IMMEDIATELY AFTER ROUGH GRADING. (OTHER EXPOSED AREAS SHALL BE STABILIZED PER EROSION CONTROL NOTES BELOW) 9. INSTALL UTILITIES AND OTHER SITE IMPROVEMENTS, INCLUDING FRONTAGE IMPROVEMENTS. 10. STABILIZE AND COMPOST AMEND ALL EXPOSED SOILS PRIOR TO REVEGETATION OF ENTIRE SI TE. 11. ESTABLISH LANDSCAPING AND PERMANENT VEGETATION. ALL TEMPORARY EROSION CONTROL MEASURES SHALL BE REMOVED UPON FINAL SITE STABILIZATION AND APPROVAL BY CITY INSPECTOR. Know what% below, Call bef are you dig. LOT 1: 21228 82ND PL W (BLD2020-0687) LOT 2. 21226 82ND PL W (BLD2020-0689) LOT J. 21224 82ND PL W (BLD2020-0688) LOT 4: 21222 82ND PL W (BLD2020-0690) APPROVED FOR CONSTRUCTION CITY OF EDMONDS DATE: BY - CITY ENGINEERING DIVISION RAM ENGINEERING, INC. Civil Engineering / Land Planning 16531 13TH AVE W, SUITE A108 LYNNWOOD, WA 98037 PHONE: (425) 678-6960 WWW.RAMENGINEERINGINC.COM o a v a z z 0 � 0 U W � 2 U o� W Q � a o� '0© Z C4 k �O was,, i0 d 38508 lkZ \� EGISTEg��� IONe 1. ENGINEER. ROB L. LONG, PE DRAWN B Y.- BRIAN CLARK ISSUE DATE.- SCALE.• 412112020 AS N07ED JOB N0: 20-003 SHEET.- TP-0 1 SHT 4 OF 14 2" x 2" WOOD/STEEL FILTER FABRIC SECURED TO 2" x 2" 14 GA WIRE FABRIC EQUAL NATIVE BACKFILL MATERIAL io N NOTES: FILTER FABRIC MATERIAL IN CONTINOUS ROLLS USE STAPLES OR WIRE RINGS TO ATTACH FABRIC TO WIRE 2" x 2" WOOD/STEEL POSTS -\ WIRE MESH FENCE TO SUPPORT FILTER FABRIC BURY BOTTOM OF FILTER MATERIAL 8" TO 12" 6' MAX 1. CONTRACTOR/DEVELOPER SHALL MAINTAIN AND ENSURE PROPER EROSION CONTROL THROUGHOUT PROJECT. 2. SILT FENCE TO BE PLACED DOWNSLOPE OF CONSTRUCTION ACTIVITY. CITY OF EDMONDS PUBLIC WORKS DEPARTMENT `S/. 18y., CITY INSPECTION REQUIRED ON ALL EROSION CONTROL METHODS BEFORE OTHER WORK CAN BEGIN FILTER FABRIC FENCE FILTRATION SYSTEMS APPROVED BY: R. ENGLISH REVISION DATE JANUARY 2018 STANDARD DETAIL ER-900 Option (Choose one) Turf (grass or lawn) Areas Planting Bed Areas 1 - Compost -Amend existing soils (See 1. Ensure that there is at least 6 inches (in) of existing soil in the 1. Ensure that there is at least 5 in of existing soil in the disturbed area Figure 1 for turf and disturbed area (if not add topsoil). (if not add topsoil). Figure 2 for planting 2 Place 1 1/2 to 1 3/ in of compost on top of existing soil. Till or 2. Place 3 in of compost on top of existing soil. Till or otherwise mix beds) otherwise mix the compost into the top 6 inches of existing soil such the compost into the top 6 inches existing soil such that the depth that the depth right after mixing is about 9.5 in (mixing will entrain air right after mixing is about 9.5 in (mixing will entrain air into the into the mixture and make it fluffy). It may be necessary to loosen mixture make it fluffy). It may be necessary to loosen (scarify) (scarify) existing soil to facilitate this mixing. existing soil to facilitate this mixing. 3. Water or roll to slightly compact to the 9.5 inch compost -amended 3. Water or roll to slightly compact to the 9.5 inch compost -amended soil layer to approximately 8 inches. soil layer to approximately 8 inches. 4. Rake to smooth and remove surface woody debris and rocks larger 4. Rake to smooth and remove surface rocks larger than 2 inch in than 1 inch in diameter (if any). diameter (if any) 5. Mulch planting beds with 2 to 4 inches of organic mulch (i.e., For 100 square feet of turf area: A 1 1/2 to 1 3/ inch lift requires -14 cubic arborist wood chips, leaves, bark) - Recommended not required. feet or --1/2 cubic yard of compost. For 100 square feet of planting bed area: A 3 inch lift requires 25 cubic feet or -1 cubic yard of compost. 2 - Import I. Place a 3 inch thick layer of a topsoil/compost mixture that contains 1. Place a 3 inch thick layer of a topsoil/compost mixture that contains Topsoil/Compost Mix 4% to 5% organic matter (typically 25-35% compost by volume - the approximately 10% organic matter (typically 40% compost by balance shall be sand and or sandy loam soil). volume) - the balance shall be sand and or sandy loam soil). 2. Till or otherwise mix into the top 2 inches of existing soil. It may be 2. Till or otherwise mix into the top 2 inches of existing soil. It may be necessary to loosen (scarify) existing soil to facilitate this mixing. necessary to loosen (scarify) existing soil to facilitate this mixing. 3. Place a second lift of 3 inches of the topsoil/compost mixture on the 3. Place a second lift of 3 inches of the topsoil/compost mixture on the surface. surface. 4. Water or roll to slightly compact. 4. Rake to smooth and remove surface rocks larger than 2 inch in 5. Rake to smooth and remove surface woody debris and rocks larger diameter (if any) than 1 inch in diameter (if any). 5. Mulch planting beds with 1 to 2 inches of organic mulch (i.e., leaves, bark) - Recommended not required. For 100 square feet of turf area: each 3 inch lift will require 25 cubic feet (-I cubic yard) of the topsoil/compost mix. This mix will have For 100 square feet of planting bed area: the each 3 inch lift will require approximately 30% compost by volume (0.3 cubic yards, -- 8.1 cubic feet) 25 cubic feet (-1 cubic yard) of the topsoil/compost mix. This mix will and 70 % topsoil by volume (0.7 cubic yards, -19 cubic feet). have approximately 40% compost by volume (0.4 cubic yards, --I I cubic feet) and 60 % topsoil by volume (0.6 cubic yards, -16 cubic feet). COMPOST -AMENDED SOILS REQUIREMENT FOR TURF AND PLANTING BED AREAS U o� Qn ° Lo j O 0 I Q) � o N .c I � oa o� N O i k > � � O NZZ NE 1/4, SEC 30, TWP 27N, RGE 4E, W.M. _LS A TH IN DE FULL WIDTH GRESS/EGRESS DETAIL NOTES: 1O THE MINIMUM LENGTH SHALL BE EXTENDED AS NECESSARY TO ENSURE MATERIAL IS NOT TRACKED OFF SITE AND/OR INTO THE PUBLIC RIGHT-OF-WAY. O ATB DRIVEWAY RAMP AND/OR SITE ACCESS ROAD 15' WIDE MIN. SEE TABLE BELOW FOR REQUIRED LENGTH. NOTES: 1. SURFACE WATER - ALL SURFACE WATER FLOWING OR DIVERTED TOWARD CONSTRUCTION ENTRANCES SHALL BE PIPED ACROSS THE ENTRANCE. IF PIPING IS IMPRACTICAL, A MOUNTABLE BERM WITH 5:1 SLOPES WILL BE PERMITTED. 2. MAINTENANCE - THE ENTRANCE SHALL BE MAINTAINED IN A CONDITION WHICH WILL PREVENT TRACKING OR FLOWING OF SEDIMENT OFF SITE AND/OR ONTO PUBLIC RIGHT-OF-WAY. THIS MAY REQUIRE PERIODIC TOP DRESSING WITH ADDITIONAL QUARRY SPALLS AS CONDITIONS DEMAND AND REPAIR AND/OR CLEANOUT OF ANY MEASURES USED TO TRAP SEDIMENT. ALL SEDIMENT SPILLED, DROPPED, WASHED OR TRACKED OFF SITE AND/OR ONTO PUBLIC RIGHT-OF-WAY MUST BE REMOVED IMMEDIATELY. 3. WHEELS SHALL BE CLEANED TO REMOVE SEDIMENT PRIOR TO LEAVING THE SITE. WHEN WASHING IS USED, IT SHALL BE DONE ON AN AREA STABILIZED WITH QUARRY SPALLS AND WHICH DRAINS INTO AN APPROVED SEDIMENT TRAPPING DEVICE. 4. INSPECTION AND NEEDED MAINTENANCE SHALL BE PROVIDED AFTER EACH RAIN. PROJECT SIZE MIN LENGTH OF (FEET) QUARRY SPALLS* < 1/4 ACRE 30 < 1 ACRE 50 < 3 ACRE 100 > 3 ACRE 100 `Sf. 18-� - *PROVIDE ATB OR ASPHALT TRANSITION WHERE FRONTAGE ROAD IS AN ARTERIAL. LENGTH TO BE DETERMINED BY CITY INSPECTOR. CITY INSPECTION REQUIRED ON ALL EROSION CONTROL METHODS BEFORE OTHER WORK CAN BEGIN CITY OF EDMONDS STABILIZED CONSTRUCTION ENTRANCE PUBLIC WORKS DEPARTMENT APPROVED BY: R. ENGLISH REVISION DATE JANUARY 2018 STANDARD DETAIL ER-901 O O O 0 O O 0 O O O O O , O O O O � O d: O O O i �8 e� FILTERI SOCK WITH OVER FLOW HOLES (TYP) 4 Ad FILTER SOCK WITH OVER FLOW HOLES (TYP) Lr�IN] NOTES: CATCH BASIN 1. CONTRACTOR/DEVELOPER SHALL MAINTAIN THIS APPLICATION AT ALL TIMES DURING CONSTRUCTION PERIOD. 2. ANY SEDIMENT IN CATCH BASIN INSERT SHALL BE REMOVED WHEN INSERT IS ONE-THIRD FULL. 3. CITY INSPECTION REQUIRED ON ALL EROSION CONTROL METHODS BEFORE OTHER WORK CAN BEGIN. REVISION DATE CITY OF EDMONDS TEMPORARY JANUARY 2018 SEDIMENT TRAP PUBLIC WORKS FOR CATCH BASINS STANDARD DEPARTMENT DETAIL APPROVED BY: R. ENGLISH E R- 9 0 2 Know what% below, Call bef are you dig. LOT 1: 21228 82ND PL W (BLD2020-0687) LOT 2. 21226 82ND PL W (BLD2020-0689) LOT J. 21224 82ND PL W (BLD2020-0688) LOT 4: 21222 82ND PL W (BLD2020-0690) APPROVED FOR CONSTRUCTION CITY OF EDMONDS DATE: BY - CITY ENGINEERING DIVISION RAM ENGINEERING, INC. Civil Engineering / Land Planning cc 16531 13TH AVE W, SUITE Al08 LYNNWOOD, WA 98037 PHONE: (425) 678-6960 WWW.RAMENGINEERINGINC.COM �- I IAIM© /�0 fv w s� i0 /� ,z d � 38508 CZ% \� EGISTEg��� IONe 1. //////26 20 ENGINEER. ROB L. LONG, PE DRAWN B Y.- BR/AN CLARK ISSUE DATE.- SCALE.• 412112020 AS NOTED J0B NO. 20-003 SHEET.- TD-01 SHT 5 OF 14 / / / i / I r / / h I I I I I I I I I L ` r---4 III II II I I II i II II II II �L-----J 28" F NE 114, SEC 30, TWP 27N, RGE 4E, W.M. CB 2 TYPE l 1+33.00, 0.00' RIM 419.48 6" lE 415.64 (IN -SW) 8" lE 415.64 (IN-E) CONCRETE I 8" lE 415.64 (OUT-W) I INSTALL R-TANK _ TRASH GUARD PLUS 23" W/ TRIM SEAL SEE DETAILS, THIS SHEET & DT-03 APPROX. 3, 795 CF STORAGE CB 27 (L) x 11 (W) HD TRIPLE UNITS 30' PRIVATE,ACCESS TYPE 11-54" N + 12 END HD TRIPLE UNITS I I I (TOTAL= 309 HD TRIPLE UNITS) & UTILITY EASEMENT - _-` \ FLOW CONTROL I II SEE DETAILS ON SHEETS VT-01, VT-02 & VT-03 `� \ /i'STRUCTURE ` i' 1+42.66, 13.25' RTII RIM 421.71 i \ 8" lE 414.70 (IN-1W) - ��Y $9�96'7"-i�X 2$,Q`' _ _� 8" lE 415.70 (OUTLE� J - X 424 A O ` / I 3"-8" SD @ 17,' 1 I NA I 6" PVC ROOFI-\ DRAIN. 07 MI 421.73 FG _ 421.55 FG 422.20 422.02 421.92 421.74 - FG FG I - ------------ ---- ---- -------------------- �1.45 G7.27 �- ___ _ GRADE B E7 o - 422 ad -Q ---- Q o - / I/ 1 I o Y N 1 N k v - Q ------------- - r-------- `�f t J 3 l Z 1 v j I 42225 i FG I I II I ----- r JI 4 422.25 FG , I j ----�-- - - COVERED PORCH I I 422.25 / I FG i t 422.25 FG I j I ------i 2 422.25 422.25 FG FG � - j -T, - COVERED I �`�� - J , PORCH �----------- � -- 2 `�2¢��, I I 422.25 477;7,// I I 22.25 I I FG FG I I I I PROPOSED DRY UTILI7 iE,- II --- �� - 1 'v EXISTING WA TER • I PROPOSED TOWNHOUSES SERVICE TO BEREMOVED/ 1� MAIN FF 423.00 ABANDONED COVERED GARAGE F = 422.50 1 PORCH COVERED ' PORCH I UNI T 1 UNIT 2 UNIT 3 UNIT 4 - i II I' I I I 1 IL III �I I o / FOOTING DRAIN C® 1.09 MIN / COVERED I - COVERED ; 1 PATIO PA TIO .\ PATIO PATIO SSCO SSCO---------PA770 ---- -=PA-770 ------tIS2 lE 418 8 /E 418.E 41 8 SSC0 1 1 1 1 C: APPROXIMATE I PAVEMENT CENTERLINE RIGHT- OF- WA Y CENTERLINE I - � o I N W v 23'-8" SD @ 0.609 CB 1A TYPE I 12+25.81, 19.22' LT RIM 418.36 II 8" lE 415.56 (IN-W) II 12" lE 415.56 (OUT-E) 32'-12" DI V ® 0.657 SP #2-2007-58 #201007275001 \ I CROSSING o 12 SD 1E=415.47 II I 8" SS TOP=412.6f I I I SEPARA TION=2.87 f EXIST 6" WA TER MAIN I I I TO BE POTHOLED PRIOR lo I TO CONSTRUCTION J / CROSSING 12 SD IE= 415.40 16" WA TOP=414.9i I I SEPARA TION= 0.50 t II I STORM DRAINAGE I TRENCH/PA TCH PER COE STD DTLS GU-400 & GU-410, ISHEET DT-02 C - RIM=477.95 IE 12" CPP(N)=475.35 IE 12" 415.35 (W-NEW) I J EXISTING FIRE HYDRANT J I (INSTALL 4" STORZ ADAPTOR /F NEEDED) - INSTALL BLUE REFLECTOR ON HYDRANT SIDE OF PA VEMENT � PER COE STD I DTL W-100, SHEET DT-03 I I WATER TRENCH/PA TCH PER COE STD DTLS GU-400 & GU-410, I SHEET DT-02 1 y I I �J t INSTALL (4) 1- WATER METERS 1 " PE (160 PSI) FROM WATER MAIN TO METERS & 1-1/2" PE (160) FROM METERS TO UNI TS PER COE STD DTLS GU-400, SHEET D T- 02 & W4-130, SHEET D T- 03 (TRACER WIRE TO BE U INSTALLED WITH WATER LINE) GRIND & OVERLAY PER PATCHING - - W - - - W & OVERLAY NOTE, THIS SHEET 6" PVC SIDE SEWER ® 2.09 MIN SLOPE IF PIPE SLOPE EXCEEDS 209 THE PIPE 1 UTlU7 �T 1 I I WILL BE REQUIRED TO BE ANCHORED -n CI -ME � 1 E T I lE 419.5 6" PVC SEWER I I SERVICE @ 2.07 MIN SDCO �- -� lE 41, 10' PR/ VA TE N 89 *06'47" W 128.01 ' CONNECT SEWER LATERALS SEWER WITH WYES (TYP) I I ��\ EA SEMEN T N STORM DRAINAGE EASE I PER REC NO 2020101E i / / / / /1 i /I r HAWARDEN TRACTS VOL, 14, PAGE 69 ' I N I / ------ ---- I I � I I `------- i �--------- I I � I ` I C �\ L� T 30 ROW SANITARY SEWER TRENCH/PA TCH PER COE STD DTLS GU-400 & GU-410, SHEET DT-02 I � � CONNECT 6" SEWER SERVICE WITH A WYE lE 412.8f I i SSCO I I I C13 /E I RIM=478.93 Awl 10 417.3 I IE 12" RCP(N)=415.63 v- _ J I ❑ / I IE 12" RCP(S)=475.63 �J I IE 12" RCP(SW)=416.33 INSTALL 6 SANITARY SEWER I I CLEANOUT PROPERTY LINE __1 I PER COE S DTL S,I-200, SHEET DT- 3, I '0 I (SSCO TO AVE 12" LAST I IRON LAMP OLE COVER WITH 1 I L TS, TYP) HEX O Lo � �\ I I CUL VER T = `J I IE 12" RCP- 17.55 CONNECT 6" PVC TO PROPO IISTORM DRAINAGE SYSTEM o (UNDER SEPARA TE PERMIT) I U, / / J 1 IE= 418.00 I1 - _ 1 I r T\ I SCALE. 1" = 10' 0 5 10 20 PATCH/NG/OVERLAY NOTE UTILITY PATCHES WITH LESS THAN 20-FEET OF SEPARATION SHALL BE COMBINED AND FULL WIDTH OR HALF WIDTH OVERLAY WILL BE REQUIRED DEPENDING ON THE EXTENT OF DISTURBANCE, WHERE UTILITY PATCHES FALL ENTIRELY WI THIN ONE TRAVEL LANE, THE OVERLAY SHALL EXTEND TO THE CENTERLINE OF ROADWAY. WHERE UTILITY PATCHES EXTEND INTO BOTH TRAVEL LANES THEN A FULL WIDTH OVERLAY IS REQUIRED. STORM DRAINAGE NOTES IF THE RIM TO INVERT OF ANY CATCH BASIN EXCEEDS 5 FEET A TYPE ll CATCH BASIN WILL BE REQUIRED. SEWER SERVICE NOTES 1. CLEANOUTS ARE REQUIRED AT PROPERTY LINE, EDGE OF EASEMENT AND AT THE END OF SIDE SEWER RUNS (SEE PLAN). LOCKING Cl LAMPHOLE COVERS SHALL BE INSTALLED AT PROPERTY LINE CLEANOUTS AND ON CLEANOUTS LOCATED IN HARD SURFACES. 2. 6" CLEANOUTS REQUIRED AT THE PROPERTY LINE SHALL BE INSTALLED WITH 12" LAMPHOLE COVER WI TH 1/2" HEXBOL TS. J. SIDE SEWER SERVICES & CLEANOUTS TO BE INSTALLED PER COE ST9 DTLS SS-200 & SS-202. FIRE/AID ADDRESS SIGNS THE CONTRACTOR/PROPERTY OWNER TO CONTACT THE ENGINEERING DI VISION BY EMAIL AT ENGINEERINGPERMI TS(OEDMONDSWA. GO V 2-WEEKS IN ADVANCE OF THE REQUESTED SIGN FABRICATION. 6" SD FROM ROOF DRAIN SYSTEM 8" SO TO R-TANK I 8" SD FROM CB-3 Q Q Q INSTALL R-TANK TRASH GUARD PLUS 23" W/ TRIM SEAL SEE DETAIL, SHEET DT-03 NOTE.• TRASH GUARD ONLY FITS ON LONG DIMENSION OF TYPE 1 CB. CONTRACTOR TO INSTALL CB ENSURING THE PROPER ROTATION SO THAT THE TRASH GUARD FACES WEST. C6 2, TYPE I SCALE 1" = 2' Know what% below, Call bef are you dig. RAM ENGINEERING, INC. Civil Engineering / Land Planning 16531 13TH AVE W, SUITE A108 LYNNWOOD, WA 98037 PHONE: (425) 678-6960 WWW.RAMENGINEERINGINC.COM O U 2 2 cc 0 � 0 U W� 2 U 0 pc W N o W Q � ti 0 0 �o was,, i0 d \� EGISTEg��� IONe 1. PLN2020-0029 ENGINEER: LOT 1: LOT 2. 21228 21226 82ND 82ND PL PL W W (BLD2020-0687) (BLD2020- 0689) ROB L. LONG, PE DRAWN B Y.- LOT J. 21224 82ND PL W (BLD2020-0688) BR/AN CLARK LOT 4: 21222 82ND PL W (BLD2020-0690) ISSUE DATE SCALE 4121/2020 AS NOTED CITY OF EDMONDS JOB NO. 20-003 DATE: SHEET.- RS-01 BY- CITY ENGINEERING DIVISION T 6 OF 14 SH U m� I 0 E� A- o I � 3 o� o� N Q) 0 co Zi o X > � pro. NZ2 424 412 424 420 PROPOSED FRONTAGE IMPROVEMENTS (UNDER SEPARATE PERMIT) n r 1 NE 1/4, SEC 30, TWP 27N, RGE 4E, W.M. 2+00 1+50 1+00 416 DUI I I_ I I --- II u 424 Io W +� ULu + O ;: PROPOSED FINISHED GRADE EXIS77NC. GRADE Z II W �3 W AT FLOWLINE OF CURB AT ROA 420 Y STORM DRA AGE — EX SEWER MAl 412 ---- 408 00 0) 82ND PL W SCALEr 1"=10' H, 1'=2' V CB 3 TYPE l RIM 418.48 8" lE 415.72 (OUT-W) CB 1A TYPE I RIM 418.36 8" lE 415.56 (IN-W) 12" IE 415.56 (OUT-E) — — - -__-- 412 32'-12" DI ® 0.657' EX CB TYPE l RIM 417.95 12" IE 415.35 (IN-W) 12" IE 415.35 (IN-S) 12" IE 415.35 (OUT-N) co j <t .; p N o^p rn N t j co j n j n rr O) of O) pj O) of ap ad Op .(o 06 O6 00 Op N Op a0 00 pj pj ?0 11+50 12+00 12+50 424 - lo 11 IfiL%P/a�III►y� !eLCCeIA 420 416 412 WIDTH VARIES (SEE NOTE 22' 5 o o PRI VA TE ROAD o o 8' 11 11' DR/ VEWA Y TRAVEL LANE TRAVEL LANE VARIES (SEE PLAN) _ 2X - 2X ROW 1 2" COMPACTED DEPTH HOT MIX ASPHALTIC (HMA), CLASS 112-INCH 4" MIN. COMPACTED DEPTH ASPHALT TREATED BASE 6" MIN. COMPACTED DEPTH GRAVEL BORROW OR SUITABLE SUBGRADE DRIVE A NOT TO SCALE 30' ROW 8' PARKING 3' MIN. 4.5' 5' (SEE PLAN) 0.5' 1' z J �S CONCRETE SIDEWALK PER -/ COE STD DTL TR-531, SHEET D T- 01 TYPE 'A" CURB/GUTTER PER COE STD DTL TR-520, SHEET DT-01 5' (TYP) 18" CURB (TYP) SEE NOTE 7) WIDTH VARIES (SEE NOTE 6) WIDTH VARIES (SEE NOTE 6) CRUSHED SURFACE BASE COURSE PER WSDOT STD SPEC 9-03.9(3) (SEE NOTE 1) HMA CLASS 1/2" PG 58H-22 (SEE NOTES 2 & 3) NOTES: 1. CSBC DEPTH SHALL BE A MINIMUM 6" OR MATCH EXISTING WHICHEVER IS GREATER. CSBC SHALL BE INSTALLED IN MULTIPLE LIFTS OF EQUAL THICKNESS WHEN EXCEEDING 6" THICKNESS. 2. ROADWAY HMA DEPTH SHALL BE A MINIMUM OF 4" THICK. UNLESS APPROVED BY THE ENGINEER, ANY DEPTH GREATER THAN 4" SHALL MATCH EXISTING. 3. ALLEY HMA DEPTH SHALL BE A MINIMUM OF 2" THICK. UNLESS APPROVED BY THE ENGINEER, ANY DEPTH GREATER THAN 2" SHALL MATCH EXISTING. 4. UNLESS APPROVED BY THE ENGINEER, THE HMA SHALL BE INSTALLED IN MULTIPLE EQUAL THICKNESS LIFTS NOT EXCEEDING 2". 5. FINAL PAVEMENT JOINTS SHALL BE NEATLY AND UNIFORMLY SEALED PER WSDOT STANDARD SPECIFICATIONS 5-04.3(4)A. 6. REFER TO EDMONDS COMMUNITY DEVELOPMENT CODE TABLE OF STREET STANDARDS FOR RIGHT—OF—WAY AND PAVEMENT WIDTHS. 7. REFER TO EDMONDS COMMUNITY DEVELOPMENT CODE SIDEWALK STANDARDS FOR SIDEWALK REQUIREMENTS. 8. REFER TO CITY STANDARD CURB DETAILS. `St. JB' — CITY OF EDMONDS PUBLIC WORKS DEPARTMENT PUBLIC STREET APPROVED BY: R. ENGLISH REVISION DATE FEBRUARY 2020 STANDARD DETAIL TR-505 SAWCUT LINE 29 ROW 20' PVMT 11 ' (MIN) IRA VEL LANE VARIES SEE PLAN I I PAVEMENT AND SUBGRADE DEPTHS PER COE STD DTL TR-505, THIS SHEET 82ND PL W NOT TO SCALE rl Know. what's below. Call before you dig, RAM ENGINEERING, INC. Civil Engineering / Land Planning 16531 13TH AVE W, SUITE A108 LYNNWOOD, WA 98037 PHONE: (425) 678-6960 WWW.RAMENGINEERINGINC.COM ai cn co O o U a Zco Z � g o � � U W ~ Z U J o cc � J C) O Q W Q � Q�� 0 Lo M0© �0� x O 48508 w \� �'GISTE���� IO>\re1. h'//'�/` PLN2020-0029 ENGINEER. Z Z f4 15 LOT 1: 21228 82ND PL W (BLD2020-0687) ROB L. LONG, PE L 0 T 2. 21226 82ND PL W (BLD2020— 0689) DRA WN B Y.- LOT J. 21224 82ND PL W (BLD2020-0688) BRIAN CLARK LOT 4. 21222 82ND PL W (BLD2020-0690) ISSUE DATE SCALE 412112020 AS NOTED CITY OF EDMONDS ✓oe No: 20-003 DATE: SHEET RP-01 BY - CITY ENGINEERING DIVISION SHT OF 14 X o� •� 3 ao NE 1/4, SEC 30, TWP 27N, RGE 4E, W.M. 27 (L) x 11 (W) HD TRIPLE UNITS + 12 END HD TRIPLE UNI TS 2 48' MAINTENANCE PORT (TOTAL= J09 HD TRIPLE UNITS) MAINTENANCE PORT c 8 (/ N 14.22' R-TANK DETENTION SYSTEM PLAN SCALE. 1 " = 5' a\\� 54" DIA, TYPE ll 6" PVC ELBOW 8" SD TO 8" PVC RESTRICTOR FRAME & GRATE STEP & LADDER PER COE STD DTL GU-423, SHEET D T- 02 PLAN VIEW FRAME & GRA TE TOP EL 421.71 Z% / 4 44 4 _l < qa 4 cV 4 , - < ,4 n n , d TOP EL. 419.10 OVERFLOW EL 419.00 4 (MAX WA TER SURFACE) n n L 6" ELBOW, EL. 417.90 4 8" PVC J 112"0 DIA. ORIFICE R TANK RESTRICTOR 4 DETENTION SYSTEM (TRIPLE -HD) 4 ?777 8" SD TO EX CB 4 1 _ lE 415.70 8" SD FROM >c r-1R- TANK _ Z EL. 414. 90 /E 414.70 n n �Lo / v4 A 4 8" lE 414.90 n n (INLET & OUTLET) �4/ 4a ? J n n 1 q 4 a N 1< -1 a / a a v < � 'A 4 a q ,a 4 4 54" DIA SECTION VIEW CE 1 " IE 414.90 9UTLET) lE 414.90 FROM CB 2 VLET) FLOW CONTROL ° STRUCTURE ° NON -SHRINK GROUT 4.5" 1'MIN ° COUPLING PVC PIPE STUB —1F_"T h I - -I h H AL _1L GASKET (TYP) a PVC ADAPTER W/ DOUBLE GASKET AND ADHESIVE BONDED SAND FINISH ON ° EXTERIOR. MIN 7" LONG 8" PVC PIPE CONTROL DEVICE ASSEMBL Y TO BE REMOVABLE FROM INSIDE THE FCS INVERT PVC PIPE CROSS ORIFICE PLATE 9 MM (0.3543') V ORIFICE DIAMETER CAULK SPACE BETWEEN PVC ADAPTER AND PIPE STUB DETAIL "A" CONNECTION & CONTROL DEVICE NOT TO SCALE CB 1, TYPE I/ - 54" FLOW CONTROL STRUCTURE SCALE.- 1 " = 2' OUT Know what% below, Call bef are you dig. RAM ENGINEERING, INC. Civil Engineering / Land Planning 16531 13TH AVE W, SUITE A108 LYNNWOOD, WA 98037 PHONE: (425) 678-6960 WWW.RAMENGINEERINGINC.COM �- I 00 U to O 2 cn 2 O � O U W ~ 2 U J O cc � W� o o W Q � ti a o Q) '0© �o was, i0 d 38608 lkZ \� EGISTEg��� IONe 1. 11/11/2622a PLN2020-0029 rENGINEER.. LOT 1: 21228 82ND PL W (BLD2020-0687) ROB L. LONG, PE LOT 2. 21226 82ND PL W (BLD2020— 0689) DRAWN B Y.- LOT J. 21224 82ND PL W (BLD2020-0688) BR/AN CLARK LOT 4: 21222 82ND PL W (BLD2020-0690) cSUE DATr. SCALE• 412112020 1 AS NOTED CITY OF EDMONDS JOB NO. 20-003 DATE: SHEET.- VT-01 BY- CITY ENGINEERING DIVISION 8 OF 14 SHT U o ° 5,_ Tr' mTr' 66'-0" (27 HD R-TANKS+2 ROTATED) Y • z 2'-0" STONE PERIMETER MAINTENANCE PORT R-TANKHD (TYP OF 2, LOCATIONS TO TRIPLE BE VERIFIED BY ENGINEER) (TYP. OF 309) NOTES: 1. DEAD STORAGE VOLUME FROM 414.90 TO 415.7 = 723 CF 2. LIVE STORAGE VOLUME FROM 415.7 TO 419.10 = 3,072 CF 3. BASE STONE STORAGE NOT INCLUDED IN VOLUMES. LAYOUT SCALE 1" = 10' R-TANKHD MODULE TYPE TRIPLE TRAFFIC LOAD HS-20 # OF TRIPLE R-TANKS 309 R-TANK STORAGE VOLUME 3,795 CF TOP OF COVER STONE ELEV. (12") 420.10 ACF BX-12 GEOGRID ELEV. 420.10 TOP OF R-TANK ELEV. 419.10 TANK INVERT 414.90 INVERT OF STONE BASE (3") 414.65 MIN. STONE PERIMETER WIDTH 2.0 FT SEE SHEETS 3 - 5 FOR DETAILS AND ADDITIONAL INFORMATION GEOGRID (ACF BX-12) PLACED 12" ABOVE THE R-TANKHD SYSTEM. OVERLAP ADJACENT PANELS BY 18" MIN. GEOGRID SHOULD EXTEND 3' BEYOND THE EXCAVATION FOOTPRINT. R-TANKHD UNITS WRAPPED WITH 8 OZ. NON -WOVEN GEOTEXTILE (OR EQUAL) NE 114, SEC 30, TWP 27N, RGE 4E, W.M. ENGINEER OF RECORD TO REVIEW, APPROVE 8" OUTLET PIPE AND ENDORSE CONNECTION FINAL SITE SPECIFIC DESIGN. FOR ADDITIONALINFO-ATION %.EASE CONTACT. ACF ENVIRONMENTAL 1-800448-3636 -acfenvi ronmental.c°m INLET PIPE AGF C CONNECTION LET'S GET IT DONE E 0 U m c a� E H Q Y ° Z O w - U 2 I _3co O 0 Z coW=00p Z O m U) tb It 0 10, 20' >- OZZ� ~ � Ur o SCALE 1" = 10' Y o W J Q 00 z W z w II .......................:::.::..................... ..................... �eue 3" STONE BASE R-TANKHD TANK WRAP & EXCAVATION ENVELOPE DETAIL TOTAL COVER: 20" MINIMUM AND 84" MAXIMUM. FIRST 12" MUST BE NOTES: FREE DRAINING BACKFILL (SPEC SECTION 2.03B): STONE <1.5" OR SOIL 1. FOR COMPLETE MODULE DATA, SEE APPROPRIATE R-TANKHD MODULE SHEET. (USCS CLASS GW, GP, SW OR SP). ADDITIONAL FILL MAY BE 2. INSTALLATIONS PER THIS DETAIL MEET GUIDELINES OF HL-93 LOADING PER THE AASHTO LRFD STRUCTURAL FILL (SPEC SECTION 2.03C): STONE OR SOIL (USCS BRIDGE DESIGN SPECIFICATIONS, CUSTOMARY U.S. UNITS, 7TH EDITION, 2014 WITH 2O15 AND 2016 CLASS SM, SP, SW, GM, GP OR GW) WITH MAX CLAY CONTENT<10%, INTERIM REVISIONS. MAX 25% PASSING NO. 200 SIEVE, AND MAX PLASTICITY INDEX OF 4. A 3. PRE-TREATMENT STRUCTURES NOT SHOWN. MIN. 12" COVER MUST BE MAINTAINED BETWEEN BACKFILL 4. FOR INFILTRATION APPLICATIONS, GEOTEXTILE ENVELOPING R-TANK SHALL BE ACF M200 (PER EQUIPMENT AND THE TOP OF THE R-TANKTM SYSTEM AT ALL TIMES. SPEC SECTION 2.02A) AND BASE SHALL BE 4" MIN. UNCOMPACTED FREE DRAINING BACKFILL TOTAL HEIGHT OF TOP BACKFILL SHOULD NOT EXCEED 7'. CONTACT (SPEC SECTION 2.03A) TO PROVIDE A LEVEL BASE. SURFACE MUST BE SMOOTH, FREE OF LUMPS ACF ENVIRONMENTAL IF MORE THAN TOR LESS THAN 20" OF TOP OR DEBRIS, AND EXTEND 2' BEYOND R-TANKHD FOOTPRINT. BACKFILL IS REQUIRED (FROM TOP OF TANK TO TOP OF PAVEMENT). GEOGRID (ACF BX-12) PLACED 12" ABOVE THE R-TANKHD SYSTEM. OVERLAP ADJACENT PANELS BY 18" MIN. GEOGRID SHOULD EXTEND 3' BEYOND THE EXCAVATION FOOTPRINT. UTILITY MARKERS AT PAVED SURFACE 36" (0.91 m) MIN. COVER NISH CORNERS (TYP.) GRADE TOOI OPOF TANK: 20" (0.51 m) MIN. MAX. 1I- I-I I I=I I I I_I _ III -III - I -III -III 12" (0.30 m) I-III=1I I-III=1I I -III -III III-III-III=1 I 11 I I I_I -I I I- III -I 11 I -I 1I- =III=III=III-I OPTIONAL _ _ _ � OVERFLOW I -I -III-III-III-III-III - - - - - - - PIPE _ _ _ _ _ _ _ „ _I I _I I I_I I I_I I I_I I I_I I I -III I I I_I I I_I I I_I 1(- INLET PIPE I I -I I -I I -I I -I I -I I- I -I I -III -III -III -I 11=1 I I -I 11=1 =l 11=1 11=1 11=1 11=1 11=1 11=1 I III=1 I IEI I IEI I IEI I IEI I IEI I IEI I I. 1=1 11=1 I I -I I II I I -I I I -I I I -III -III -III -III -III -III -III -I =1 I EEI I IEI I IEI 11=l 11=1 11=1 I=1 1=1 1=1 1=111=1 1=111=1 11= 1=III=III=III=III=III=III- OPTIONAL -III-III=III-III-III=111: III _ _ _ _ OUTLET I -III -III -III -III -III -III = _ -- _ . =1 j I -III -III III -III III-III--III-III III III1 III1 III1 1= i III III=1 I I -I I 1=1 I 1=1 1111= =1 1 III -III -III= _- - - - PIPE 1=11=1 -I -I-I1=11=1 I1=11= 1=11=11=11=11=11=11=11=11-11=1I-11=11=11=1I _ - 1ElI1=11=11=11=11=1IEI�EE 3"(0.08m)MIN.-II-II-II-II 11111�1111111111IIIII11�11 I�IIIIIIIII�IIII�IIII�IIII�IIII�II III I�IIII�I..II�II.IIIIIII�IIIIIIIIIIIIII�IIII�IIII�IIII�IIII�IIII�IIII�II11�1, R-TANKHD UNITS LOAD RATING: 33.4 PSI (MODULE ONLY) SUBGRADE / EXCAVATION LINE: COMPACT PER SPEC SECTION 3.02 D. A BEARING CAPACITY OF 2,000 PSF MUST BE ACHIEVED PRIOR TO INSTALLING R-TANKHD NOTES 1. THIS PORT IS USED TO PUMP WATER INTO THE SYSTEM AND RE -SUSPEND ACCUMULATED SEDIMENT SO THAT IT MAY BE PUMPED OUT. 2. MINIMUM REQUIRED MAINTENANCE INCLUDES A QUARTERLY INSPECTION DURING THE FIRST YEAR OF OPERATION AND A YEARLY INSPECTION THEREAFTER. FLUSH AS NEEDED. 3. ONLY R-TANKHD AND R-TANKSD MAY BE USED IN TRAFFIC APPLICATIONS. 4. SEE TRAFFIC LOADING DETAIL FOR MINIMUM & MAXIMUM COVER REQUIREMENTS. 5. IF MAINTENANCE PORT IS LOCATED IN A NON -TRAFFIC AREA, A PLASTIC CAP CAN BE USED IN LEU OF A FRAME AND COVER WITH CONCRETE COLLAR. 24" (0.61 m) BASE: 3" MIN. BEDDING MATERIAL (SPEC SECTION 2.03A) MAY BE STONE (<1.5") OR SOIL (USCS CLASS GW, GP, SW OR SP). MUST BE FREE OF LUMPS AND DEBRIS, AND EXTEND 2' BEYOND R-TANKHD. COMPACT PER SPEC SECTION 3.03 A. NATIVE SOILS MAY BE USED IF THEY MEET THE REQUIREMENTS OF SPEC SECTION 2.03A AND ARE ACCEPTED BY OWNER'S ENGINEER. SIDE BACKFILL: 24" MIN. OF FREE DRAINING BACKFILL (SPEC SECTION 2.03B): STONE <1.5" OR SOIL (USCS CLASS GW, GP, SW OR SP). MUST BE FREE FROM LUMPS, DEBRIS AND OTHER SHARP OBJECTS. SPREAD EVENLY TO PREVENT R-TANKHD MOVEMENT. COMPACT SIDE BACKFILL WITH POWERED MECHANICAL COMPACTOR IN 12" LIFTS (PER SPEC SECTION 3.05 A2). R-TANKHD & H-20 LOADS - SECTION VIEW 16.25" FRAME REINFORCED CONCRETE COLLAR AND COVER (WHERE REQUIRED), 12" DIA. PVC MIN. 1" CLEARANCE FROM PVC MAINTENANCE PORT PAVED SURFACE BACKFILL COMPACTED TO 95% STANDARD PROCTOR DENSITY , GEOGRID (REQUIRED IN TRAFFIC AREAS) 12 NON -CORROSIVE SOLID PLATE NOTCH BOTTOM OF PIPE PLASTIC, SLATE OR EQUIVALENT (SEE PATTERN) 6.49" REF. A 2.00" 2.00"SPACING REF. ��mmm 0 0 00 0 0 00 T_ m 0 00 0 0 00 CD 0 00 00.75" TYP. o. ooae� o ° o 11. 2.00" B 00.38" TYP. 00.38" TYP. 1.00" SPACING REF. 00000��0000000��oo 0 oo00000000000000000000° 00000000000000000000D °o 0 0 0 0 0 0 0 0 0 0° ° D °° ° DDD DDD ° o°o°o°oo°o°o°o°oo°o°o °°°°°°°°°°°°°°°D°°o°°° ° o o o o o o oO o o o000000000000° 00.38" TYP. O D O O O O O O O o 0 0 0 0 0 0 0 0 0 0 o o 0 0 0 0 0 0 0 0 0 0 1.00" TYP. SIZE A B 23" x 24" 23" 26.51" 28" x 30" 28" 33.15" 34" x 36" 34" 38.69" t0.25" TOLERANCE ON DIMENSIONS TRASHGUARD PLUS PRETREATMENT DETAIL nl.srr 8" NOTCHES CUT IN SHADED cs AREAS (8 OPENINGS TOTAL) PIPE NOTCHING PATTERN NON -CORROSIVE HOSE CLAMP GEOTEXTILE (AS SPECIFIED) 1" +/- VENTING PERFORATIONS R-TANKHD TYPICAL MAINTENANCE PORT DRAWN BY JPS/EDQ DATE 10/28/20 HEET NO 1 of 5 ENGINEER OF RECORD TO REVIEW, APPROVE AND ENDORSE FINAL SITE SPECIFIC DESIGN. FOR ADDITIONAL INFO-ATION PLEASE CONTACT: a F ENVIRONMENTAL 1-800-448-3636 www.acfenvi ron menta Isom AC LET'S GET IT DONE E 0 m m E Q Y o ZZ > Q 0 a� l__ U) m o 2 - 3 O5z3 O � Z = O 22 HOb ZZco Q cn O� o 0 o G7 - Y Z Z W z�0C)< 2 W w rY 0 > z w w U ¢ DRAWN BY JPS/EDQ DATE 10/28/20 SHEET NO. 3of5 GEOMETRY: LOAD RATING: LENGTH = 28.15 IN. (715 MM) 33.4 PSI, (MODULE ONLY) WIDTH = 15.75 IN. (400 MM) HS20, (WITH ACF COVER SYSTEM) HEIGHT = 50.39 IN. (1280 MM) MATERIAL: TANK VOLUME = 12.93 CF 100% RECYCLED POLYPROPYLENE STORAGE VOLUME = 12.28 CF SMALL PLATES PER VOID INTERNAL VOLUME: 95% SEGMENT/TOTAL: VOID SURFACE AREA: 90% 5/15 TRIPLE R-TANKHD - ELEVATION TRIPLE R-TANKHD - MODULE DETAIL CUT AN "X" IN THE FABRIC ENVELOPE THAT IS SLIGHTLY GEOTEXTILE FABRIC LARGER THAN THE PIPE. PULL THE FABRIC FLAPS AROUND OVER ACF R-TANK THE PIPE, AND SEAL WITH A STAINLESS STEEL BAND. NOTE: PIPE MUST BUTT DIRECGEOTEXTILEAGAINST R-TANK. PIPE EFFLUFABRIC INLET/OUTLET SHALL NOT PASS THROOVER ACF PIPE FABRICENVELR-TANK"X" AN CUT IN THE FABRIC TO AFTER TANK WRAP ISSECURED TO PIPE, SLIDE STAINLESS STEEL BAND U0� ALLOW PIPE/TANK BOOT AGAINST R-TANK ANDINTERFACE FASTEN FABRIC TO PI SECURE WITH SECONDTO STAINLESS STEEL BAND, THEN TO PREVENT BACKFILL FROM ATTACH BOOT FLAP TO TANK ENTERING STRUCTURE ENVELOPE FABRIC WITH DUCT END VIEW OF PIPE/FABRIC CONNECTION TAPE OR OTHER ADHESIVE. SIDE VIEW OF PIPE/FABRIC CONNECTION PIPE FABRIC COLLAR TO FIT OUTSIDE GEOTEXTILE FABRIC DIAMETER OF INLET/OUTLET PIPE I- 5 0' OVER ACF R-TANK�1101;0e� t �I i i, 12 OZ/SY NON -WOVEN ��\��\:��\\ PIPE GEOTEXTILE, TRIM AS ;\� ``�;`\\\ O.D. NEEDEDui STAINLESS \\�\ . \•``,`�`, �`` STEEL BAND STAINLESS STEEL BAND GEOTEXTILE BOOT FRONT VIEW OF GEOTEXTILE BOOT SIDE VIEW OF GEOTEXTILE BOOT R-TANKHD TYPICAL TANK INLET/OUTLET W/ GEOTEXTILE PIPE BOOT DETAIL R-TANKHD QUANTITIES R-TANKHD MODULE TYPE TRIPLE # OF TRIPLE R-TANKS 309 R-TANK STORAGE VOLUME 3,795 CF STONE BED FOOTPRINT 1,290 SF STONE QUANTITY 112 CY 8 OZ. NON -WOVEN GEOTEXTILE TANK WRAP 2,966 SF (330 SY) ACF BX-12 GEOGRID 2,135 SF (237 SY) 12" MAINTENANCE PORTS 2 8" PIPE BOOTS 2 NOTE: STONE QUANTITY INCLUDES 12" OF COVER AND 3" OF BASE. NOTE: GEOTEXTILE / LINER QUANTITIES INCLUDE A 15% WASTE FACTOR. NOTES: 1. DEAD STORAGE VOLUME FROM 414.90 TO 415.7 = 723 CF 2. LIVE STORAGE VOLUME FROM 415.7 TO 419.10 = 3,072 CF 3. BASE STONE STORAGE NOT INCLUDED IN VOLUMES. Know. what's below. Call before you dig, ENGINEER OF RECORD TO REVIEW, APPROVE AND ENDORSE FINAL SITE SPECIFIC DESIGN. FOR ADDITIONALINFO-ATION %.EASE CONTACT: ACE ENVIRONMENTAL 1-800-448-3636 -.acfe.. ronmental.- Acr LET'S GET IT DONE E 0 U m c a� E U) Q Y o Z > Q w U WWW l2r_ 3 �OOZ� W= = 0Q, � Z � cn 0O OD Z Z v (n Ur o Cn 0? Y06U)- J Z 00 O z IT Q g W G7 0 > z w LL U DRAWN BY JPS/EDQ DATE 10/28/20 SHEET NO. 2of5 � '' 0a1I1__%J LOT 1: 21228 82ND PL W (BLD2020-0687) LOT 2: 21226 82ND PL W (BLD2020-0689) LOT J. 21224 82ND PL W (BLD2020-0688) LOT 4: 21222 82ND PL W (BLD2020-0690) APPROVED FOR CONSTRUCTION CITY OF EDMONDS DATE: BY - CITY ENGINEERING DIVISION RAM ENGINEERING, INC. Civil Engineering / Land Planning 16531 13TH AVE W, SUITE A108 LYNNWOOD, WA 98037 PHONE: (425) 678-6960 WWW.RAMENGINEERINGINC.COM Ca z z O 0 ♦` Q. U 14 2 2 � o U W ~ 2 U o � W Q � ti 0 Lo 0 �o fv , i0 x d 0, 38608 W �'GISTE���� ENGINEER: ROB L. LONG, PE DRAWN B Y.- BR/AN CLARK ISSUE DATE: SCALE.• 412112020 AS NOTED JOB NO. 20-003 SHEET VT-02 SHT 9 OF 14 DUMP TRUCKS AND PANS SHALL NOT OPERATE OVER THE SYSTEM EXCAVATION AREA BACKFILL MATERIAL UNLOADED OUTSIDE OF THE SYSTEM EXCAVATION AREA DUMP TRUCK DETAIL (SEE NOTE 3) LOW GROUND PRESSURE DOZER (10 TON MAX, SEE NOTE 2) SMOOTH DRUM ROLLER STATIC MODE (6 TON MAX, SEE NOTE 1) R-TANKHD OR R-TANKSD UNITS HD: LOAD RATING: 33.4 PSI (MODULE ONLY) SD: LOAD RATING: 40 PSI (MODULE ONLY) NE 1/4, SEC 30, TWP 27N, RGE 4E, W.M, NOTES: 1. FOLLOWING PLACEMENT OF SIDE BACKFILL, A UNIFORM 12" LIFT OF THE FREELY DRAINING MATERIAL (SPEC SECTION 2.03 B) SHALL BE PLACED OVER THE R-TANK AND LIGHTLY COMPACTED USING A WALK -BEHIND TRENCH ROLLER. ALTERNATELY, A ROLLER (MAXIMUM GROSS VEHICLE WEIGHT OF 6 TONS) MAY BE USED. ROLLER MUST REMAIN IN STATIC MODE UNTIL A MINIMUM OF 24" OF COVER HAS BEEN PLACED OVER THE MODULES. SHEEP FOOT ROLLERS SHOULD NOT BE USED. SPEC SECTION 3.05 A 2. ONLY LOW PRESSURE TIRE OR TRACK VEHICLES (LESS THAN 7 PSI AND OPERATING WEIGHT OF LESS THAN 20,000 LBS) SHALL BE OPERATED OVER THE R-TANK SYSTEM DURING CONSTRUCTION. SPEC SECTION 3.05 B 3. DUMP TRUCKS AND PANS SHALL NOT BE OPERATED WITHIN THE R-TANK SYSTEM AT ANY TIME. WHERE NECESSARY, THE HEAVY EQUIPMENT SHOULD UNLOAD IN AN AREA ADJACENT TO THE R-TANK SYSTEM AND THE MATERIAL SHOULD BE MOVED OVER THE SYSTEM WITH TRACKED EQUIPMENT. SPEC SECTION 3.05 B 4. ENSURE THAT ALL UNRELATED CONSTRUCTION TRAFFIC IS KEPT AWAY FROM THE LIMITS OF EXCAVATION UNTIL THE PROJECT IS COMPLETE AND FINAL SURFACE MATERIALS ARE IN PLACE. NO NON -INSTALLATION RELATED LOADING SHOULD BE ALLOWED OVER THE R-TANK SYSTEM UNTIL THE FINAL DESIGN SECTION HAS BEEN CONSTRUCTED (INCLUDING PAVEMENT). SPEC SECTION 3.05 C 5. SEE R-TANK INSTALLATION GUIDE OR CONTACT YOUR LOCAL ACF REPRESENTATIVE FOR ADDITIONAL INFORMATION. SUBGRADE / EXCAVATION LINE: COMPACT PER SPEC SECTION 3.02 D. A BEARING CAPACITY OF 2,000 PSF MUST BE ACHIEVED PRIOR TO INSTALLING R-TANKHD OR R-TANKSD SMOOTH DRUM ROLLER VIBRATORY MODE (6 TON MAX, SEE NOTE 1) . .................. 24" MIN. COVER GEOGRID (SEE NOTE 1) REINFORCEMENT LAYER (ACF BX-12) CONSTRUCTION EQUIPMENT COVER DETAIL - VEHICULAR TRAFFIC ENGINEER OF RECORD TO REVIEW, APPROVE AND ENDORSE FINAL SITE SPECIFIC DESIGN. FOR ADDITIONALINFO-ATION %.EASE CONTACT. \CF ENVIRONMENTAL 1-800448-3636 -actenvironmental.wm AOF LET'S GET IT DONE J H W 0 O U LU f0 i E Q Y o Z _ c Q ill W _ 7LLI m Z �'7(=�pr� 0 Z = _ M LU 0 I- W Z0ZZ'T 0 U00U) w D 0 0 0 z 2ww Z ��_ 2 (no Of 0 Z W 2 LL Y Q Z Q DRAWN BY JPS/ED Q 10/28/20 SHEET NO. 4 of 5 R-TANK SPECIFICATION PART 1 - GENERAL PART 3 - EXECUTION 1.01 Related Documents 3.01 Assembly of R-Tank Units A. Drawings, technical specification and general provisions of the Contract as modified herein apply to this section. A. Assembly of modules shall be performed in accordance with the R-Tank Installation Manual, Section 2. 1.02 Description of Work Included 3.02 Layout and Excavation A. Provide excavation and base preparation per geotechnical engineer's recommendations and/or as shown on the design drawings, to provide adequate support for project design loads A. Installer shall stake out, excavate, and prepare the subgrade area to the required plan grades and dimensions, ensuring that the excavation is at least 2 feet greater than R-Tank and safety from excavation sidewall collapse. Excavations shall be in accordance with the owner's and OSHA requirements. dimensions in each direction allowing for installation of geotextile filter fabric, R-Tank modules, and free draining backfill materials. B. Provide and install R-Tank!LD, R-TankHD, R-TanksD, or R-TankuD system (hereafter called R-Tank) and all related products including fill materials, geotextiles, geogrids, inlet and outlet B. All excavations must be prepared with OSHA approved excavated sides and sufficient working space. pipe with connections per the manufacturer's installation guidelines provided in this section. C. Protect partially completed installation against damage from other construction traffic by establishing a perimeter with high visibility construction tape, fencing, barricades, or other C. Provide and construct the cover of the R-Tank system including; stone backfill, structural fill cover, and pavement section as specified. means until construction is complete. D. Protect R-Tank system from construction traffic after installation until completion of all construction activity in the installation area. D. Base of the excavation shall be uniform, level, and free of lumps or debris and soft or yielding subgrade areas. A minimum 2,000 pounds per square foot bearing capacity is required. 1. Standard Applications: Compact subgrade to a minimum of 95% of Standard Proctor (ASTM D698) density or as required by the Owner's engineer. 1.03 Quality Control 2. Infiltration Applications: Subgrade shall be prepared in accordance with the contract documents. Compaction of subgrade should not be performed in infiltration applications. A. All materials shall be manufactured in ISO certified facilities. E. Unsuitable Soils or Conditions: All questions about the base of the excavation shall be directed to the owner's engineer, who will approve the subgrade conditions prior to placement B. Installation Contractor shall demonstrate the following experience: of stone. The owner's engineer shall determine the required bearing capacity of the R-Tank subgrade; however in no case shall a bearing capacity of less than 2,000 pounds per 1. A minimum of three R-Tank or equivalent projects completed within 2 years; and, square foot be provided. 2. A minimum of 25,000 cubic feet of storage volume completed within 2 years. 1. If unsuitable soils are encountered at the subgrade, or if the subgrade is pumping or appears excessively soft, repair the area in accordance with contract documents and/or as 3. Contractor experience requirement may be waived if the manufacturer's representative provides on -site training and review during construction. directed by the owner's engineer. C. Installation Personnel: Performed only by skilled workers with satisfactory record of performance on bulk earthworks, pipe, chamber, or pond/landfill construction projects of 2. If indications of the water table are observed during excavation, the engineer shall be contacted to provide recommendations. comparable size and quality. 3. Do not start installation of the R-Tank system until unsatisfactory subgrade conditions are corrected and the subgrade conditions are accepted by the owner's engineer. D. Contractor must have manufacturer's representative available for site review if requested by Owner. 3.03 Preparation of Base 1.04 Submittals A. Place a thin layer (3" unless otherwise specified) of bedding material (Section 2.03 A), over the subgrade to establish a level working platform for the R-Tank modules. Level to within A. Submit proposed R-Tank layout drawings. Drawings shall include typical section details as well as the required base elevation of stone and tanks, minimum cover requirements and I/V (+/-'/4") or as shown on the plans. Native subgrade soils or other materials may be used if determined to meet the requirements of 2.03 A and are accepted by the owner's tank configuration. engineer. B. Submit manufacturer's product data, including compressive strength and unit weight. 1. Standard Applications: Static roll or otherwise compact bedding materials until they are firm and unyielding. C. Submit manufacturer's installation instructions. 2. Infiltration Applications: Bedding materials shall be prepared in accordance with the contract documents. D. Submit R-Tank sample for review. Reviewed and accepted samples will be returned to the Contractor. B. Outline the footprint of the R-Tank system on the excavation floor using spray paint or chalk line to ensure a 2' perimeter is available around the R-Tank system for proper installation E. Submit material certificates for geotextile, geogrid, base course and backfill materials. and compaction of backfill. F. Submit required experience and personnel requirements as specified in Section 1.03. G. Any proposed equal alternative product substitution to this specification must be submitted for review and approved prior to bid opening. Review package should include third party 3.04 Installation of the R-Tanks reviewed performance data that meets or exceeds criteria in Table 2.01 B. A. Where a geotextile wrap is specified on the stone base, cut strips to length and install in excavation, removing wrinkles so material lays flat. Overlap geotextile a minimum 12" or as recommended by manufacturer. Use tape, special adhesives, sandbags or other ballast to secure overlaps. As geotextiles can be damaged by extreme heat, smoking is not 1.05 Delivery, Storage, and Handling permissible on/near the geotextile, and tools using a flame to tack the overlaps, such as propane torches, are prohibited. A. Protect R-Tank and other materials from damage during delivery, and store UV sensitive materials under to to protect from sunlight when time from delivery to installation exceeds 9 9 ry, tarp P 9 ry B. Where an Impervious liner for containment is specified, install the liner per manufacturer's recommendations and the contract documents. The R-Tank units shall be separated from P ( ) P P P two weeks. Storage of materials should be on smooth surfaces free from dirt mud and debris. 9 � impervious liner b a non -woven eotextile fabric installed accordance with Section 3.04A. P Y 9 B. Handling is to be performed with equipment appropriate to the materials and site conditions, and may include hand, handcart, forklifts, extension lifts, etc. C. Install R-Tank modules by placing side by side, in accordance with the design drawings. No lateral connections are required. It is advisable to use a string line to form square corners C. Cold weather: and straight edges along the perimeter of the R-Tank system. The modules are to be oriented as per the design drawing with required depth as shown on plans.. 1. Care must be taken when handling plastics when air temperature is 40 degrees or below as plastic becomes brittle. 1. For LID, HD, and SD installations, the large side plate of the tank should be placed on the perimeter of the system. This will typically require that the two ends of the tank area will 2. Do not use frozen materials or materials mixed or coated with ice or frost. have a row of tanks placed perpendicular to all other tanks. If this is not shown in the construction drawings, it is a simple field adjustment that will have minimal effect on the overall 3. Do not build on frozen ground or wet, saturated or muddy subgrade. system footprint. Refer to R-Tank Installation Guide for more details 2. For LID installations, there is no perpendicular end row required. 1.06 Preinstallation Conference. D. Wrapthe R-Tank to and sides in specified geotextile. Cut strips of geotextile so that it will cover the sides and to encapsulating the entire system to prevent backfill entry into the P P 9 P 9 P� P 9 Y P ry A. Prior to the start of the installation a reinstallation conference shall occur with the representatives from the design team the general contractor, the excavation contractor, the P P 9 9 system. Overlap geotextile 12" or as recommended b manufacturer. Take great care to avoid damage to geotextile and if specified, impervious liner during placement. Y P9 Y 9 9 9 ( P P ) 9 R-Tank installation contractor, and the manufacturer's representative. E. Identify locations of inlet, outlet and any other penetrations of the geotextile (and optional liner). These connections should be installed flush (butted up to the R-Tank) and the eotextile fabric shall be cut to enable hydraulic continuity between the connections and the R-Tank units. These connections shall be secured using pipe boots with stainless steel 9 Y tY 9PP 1.07 Project Conditions 1 pipe clamps. Support pipe in trenches during backfill operations to prevent pipe from settling and damaging the eotextile impervious liner ifs specified) or pipe. Connecting pipes at PP P PP PP 9 P P PP 9 9 9 9 � P ( P ) PP 9PP A. Coordinate installation for the R-Tanks stem with other on -site activities to eliminate all non -installation related construction traffic over the completed R-Tanks stem. No loads Y P Y 90 degree angles facilitates construction unless otherwise specified. Ensure end of pipe is installed snug against R-Tanks stem. 9 9 P PP 9 9 Y heavier than the design loads shall be allowed over the system, and in no case shall loads higher than a standard AASHTO HS20 (or HS25, depending on design criteria) load be F. Install Inspection and Maintenance Ports in locations noted on plans. At a minimum one maintenance port shall be installed within 10' of each inlet & outlet connection, and with a allowed on the system at any time. maximum spacing of one maintenance port for every 2,500 square feet. Install all ports as noted in the R-Tank Installation Guide. B. Protect adjacent work from damage during R-Tank system installation. G. If required, install ventilation pipes and vents as specified on drawings to provide ventilation for proper hydraulic performance. The number of pipes and vents will depend on the size C. All re -treatments stems to remove debris and heavy sediments must be in lace and functional prior too operation of the R-Tanks stem. Additional pretreatment measures may be P Y Y P P P Y P Y of the system. Vents are often installed using a 90 degree elbow with PVC pipe into a landscaped area with 'U" bend or venting bollard to inhibit the ingress of debris. A round level Y 9 9 PP P 9 9 9 needed if unit is operational during construction due to increased sediment loads. concrete or steel cover can be used. D. Contractor is responsible for any damage to the system during construction. 3.05 Backfilling of the R-Tank Units PART 2 - PRODUCTS A. Backfill and fill with recommended materials as follows: 2.01 R-Tank Units 1. Place freely draining backfill materials (Section 2.03 B) around the perimeter in lifts with a maximum thickness of 12". Each lift shall be placed around the entire perimeter such that A. R -Tank - Injection molded plastic tank plates assembled to form a 95% void modular structure of predesigned height (custom for each project). each lift is no more than 24" higher than the side backfill along any other location on the perimeter of the R-Tank system. No fill shall be placed over top of tanks until the side backfill B. R-Tank units shall meet the following Physical & Chemical Characteristics: has been completed. PROPERTY DESCRIPTION R-Ta&D VALUE R-Tankw VALUE R-Tankso VALUE R-Tane VALUE Void Area Volume available for Water storage 95% 95% 95% 95% Surface Void Area Percentage of exterior available for infiltration 90% 90% 90% 90% Verlical Com ressive Strength ASTM D2412/ASTM F2418 30.0 psi 33.4 psi 42.9 psi 134.2 psi Lateral Compressive strength ASTM D2412/ASTM F2418 20.0 psi 22.4 psi 28.9 psi WA HS-20 Minimum Cover r Cove required red to support HS-20 loads WA 20 18 " srweeAarnu 12 1 H - S 25 Minimum Cover very ire loads Co e u tl m support HS-25 ds WA 24 19 "srweeAarnu 15 i Maximum Cover Maximum allowable cover depth 3feet <7feet <10 feet 5feet Unit Weight Wei ht of las5c per cubic foot of tank 3.29 Ibs/ef 3.6loll 21lo 3.96lbs/of 4.33 lbs/of Rib Thickness IThiolkness of load-bearin members 0.18 inches 0.18 inches 1 0.18 inches WA Service Temperature I Safe temperature range for use AA-167'F I AA-167-r I -14-167°F I -14-167-F 2. Each lift shall be compacted at the specified moisture content to a minimum of 95% of the Standard Proctor Density until no further densification is observed for self -compacting P P tY ( P 9 stone materials). The side lifts must be compacted with walk behind compaction equipment. Even when "self -compacting" backfill materials are selected, a walk behind vibratory compactor must be used. 3. Take care to ensure that the compaction process does not allow the machinery to come into contact with the modules due to the potential for damage to the geotextile and R-Tank units. 4. No compaction equipment is permissible to operate directly on the R-Tank modules. 5. Top Backfill: a. Typical Applications: Install a 12" (or as shown on plans) lift of freely draining material (Section 2.03 B) over the R-Tank Units, maintaining 12" between equipment tracks and R-Tank System. Lightly compacted using a walk -behind trench roller. Alternately, a roller (maximum gross vehicle weight of 6 tons) may be used. Roller must remain in static mode until a minimum of 24" of cover has been placed over the modules. Sheep foot rollers should not be used. b. Shallow Applications (< 18" total cover): Install top backfill in accordance with plans. 6. If required, install a geogrid as shown on plans. Ge rid shall extend a minimum of 3 feet beyond the limits of the excavation wall. q 9 9 P o9 Y C. Supplier: ACF Environmental 2831 Cardwell Road Richmond, VA 23234 7. Following placement and compaction of the initial cover, subsequent lifts of structural fill (Section 2.03 C) shall be placed at the specified moisture content and compacted to a (T): 800-448-3636; (F): 804-743-7779 www.acfenvironmental.com minimum of 95% of the Standard Proctor Density and shall cover the entire footprint of the R-Tank system. During placement of fill above the system, unless otherwise specified, a uniform elevation of fill shall be maintained to within 12" across the footprint of the R-Tank system. Do not exceed maximum cover depths listed in Table 2.01 B. 2.02 Geosynthetics 8. Place additional layers of geotextile and/or geogrid at elevations as specified in the design details. Each layer of geosynthetic reinforcement placed above the R-Tank system shall A. Geotextile. A geotextile envelope is required to prevent backfill material from entering the R-Tank modules. 9 P q P 9 extend a minimum of 3 feet beyond the limits of the excavation wall. 1. Standard Application: The standard geotextile shall be an 8 oz per square yard nonwoven geotextile (ACF N080 or equivalent). B. Only low pressure tire or track vehicles shall be operated over the R-Tank system during construction. No machinery should drive on top of the tank until a minimum of 18" of backfill 2. Infiltration Applications: When water must infiltrate/exfiltrate through the geotextile as a function of the system design, a woven monofilament (ACF M200 or equivalent) shall be used. and compaction is achieved. Dump Trucks and Pans shall not be operated within the R-Tank system footprint at any time. Where necessary the heavy equipment should unload in B. Geogrid. For installations subject to traffic loads and/or when required by project plans, install geogrid (ACF BX12 or equivalent) to reinforce backfill above the R-Tank system. an area adjacent to the R-Tank system and the material should be moved over the system with tracked equipment. o Geogrid is not always required for R-Tank installations, and is often not required for non -traffic load applications. C. Ensure that all unrelated construction traffic is kept away from the limits of excavation until the project is complete and final surface materials are in place. No non -installation related loading should be allowed over the R-Tank system until the final design section has been constructed (including pavement). 2.03 Backfill & Cover Materials D. Place surfacing materials, such as groundcovers (no large trees), or paving materials over the structure with care to avoid displacement of cover fill and damage to surrounding A. Bedding Materials: Stone (angular and smaller than 1.5" in diameter) or soil (GW, GP, SW, or SP as classified by the Unified Soil Classification System) shall be used below the areas. R-Tank system (3" minimum). Material must be free from lumps, debris, and any sharp objects that could cut the geotextile. Material shall be within 3 percent of the optimum moisture E. Backfill depth over R-Tank system must be within the limitations shown in the table in Section 2.01 B. If the total backfill depth does not comply with this table, contact engineer or content as determined b ASTM D698 at the time of installation. For infiltration applications bedding material shall be free draining. Y pp 9 9 manufacturer's representative for assistance. B. Side and Top Backfill: Material must be free from lumps, debris and any sharp objects that could cut the geotextile. Material shall be within 3 percent of the optimum moisture content as determined by ASTM D698 at the time of installation. PART 4 - USING THE SYSTEM 1. Traffic Applications - Free draining material shall be used adjacent to (24" minimum) and above (for the first 12") the R-Tank system. 4.01 Maintenance Requirements a. For HD and SD modules backfill materials shall be free drainingstone (angular and smaller than 1.5" in diameter or soil GW GP SW or SP as classified b the Unified Soil ( g ) ( y A. A routine maintenance effort is required to ensure proper performance of the R-Tank system. The Maintenance program should be focused on pretreatment systems. Ensuring these Classification System). structures are clean and functioning properly will reduce the risk of contamination of the R-Tank system and stormwater released from the site. Pre-treatment systems shall be b. For UD modules with less than 14" of to cover, backfill materials shall be free draining stone (angular and smaller than 1.5" in diameter). The use of soil backfill on the sides and p g ( g ) inspected yeariy, or as directed by the regulatory agency and by the manufacturer (for proprietary systems). Maintain as needed using acceptable practices or following to of the LID module is not permitted unless the modules are installed outside of traffic areas or with cover depths of 14" or more. To backfill material from to of module to bottom p p p p ( p manufacturer's guidelines (for proprietary systems). of pavement base or 12" maximum must be consistent with side backfill. p ) B. All inlet pipes and Inspection and/or Maintenance Ports in the R-Tank system will need to be inspected for accumulation of sediments at least quarterly through the first year of 2. Non -Traffic / Green Space Applications - For all R-Tank modules installed in green spaces and not subjected to vehicular loads backfill materials may either follow the guidelines for g p / y g operation and at least yearly thereafter. Traffic Applications above or the to backfill layer 12" minimum may consist of AASHTO #57 stone blended with 30-40% b volume topsoil to aid in establishing vegetation. PP P Y( ) Y (Y ) P 9 9 C. If sediment has accumulated to the level noted in the R-Tank Maintenance Guide or beyond a level acceptable to the Owner's engineer, the R-Tanks stem should be flushed. Y P 9 Y C. Additional Cover Materials: Structural Fill shall consist of granular materials meeting the gradational requirements of SM SP SW GM GP or GW as classified b the Unified Soil g g g q y D. All inspection and maintenance activities should be performed in accordance with the R-Tank Operation, Inspection &Maintenance Manual. Classification System. Structural fill shall have a maximum of 25 percent passing the No. 200 sieve, shall have a maximum clay content of 10 percent and a maximum Plasticity Index of 4. Material shall be within 3 percent of the optimum moisture content as determined by ASTM D698 at the time of installation. 2.04 Other Materials: Utility Marker: Install metallic tape at corners of R-Tank system to mark the area for future utility detection. Knawwhan below. Call before you dig, ENGINEER OF RECORD TO REVIEW, APPROVE AND ENDORSE FINAL SITE SPECIFIC DESIGN. FOR ADDITIONAL INFO-ATION %.EASE CONTACT: tCF ENVIRONMENTAL 1-800-448-3636 www.actenvi ronmental.com ACF LETS GET IT DONE E O tin c 0) E Q Y 2 Z Z Qc iU W2 I coo. a2`�� U 0 LL=0�M UZ=-co O 1b LI 0 ,Z^ U) F Cf)V COD Y 0 0 W Z N Z w Q O Z I.-_ 2 - Z I.1J C/) O Z W LL 0 Q DRAWN BY JPS/ED Q 10/28/20 SHEET NO. 5of5 j1T1ff#r#P�� LOT 1: 21228 82ND PL W (BLD2020-0687) L 0 T 2: 21226 82ND PL W (BLD2020- 0689) LOT 3: 21224 82ND PL W (BLD2020-0688) LOT 4: 21222 82ND PL W (BLD2020-0690) APPROVED FOR CONSTRUCTION CITY OF EDMONDS DATE: BY- CITY ENGINEERING DIVISION P%AM ENGINEERING, INC. Civil Engineering / Land Planning 16531 13TH AVE W, SUITE A108 LYNNWOOD, WA 98037 PHONE: (425) 678-6960 WWW.RAMENGINEERINGINC.COM L4 cc y Q O W y 2 O W O Z Q OC _M© V N 41 O J m W to o , It O \,Q 38608 w � �'GISTE���� IOnreT . 111111=0 Z to ENGINEER. ROB L. LONG, PE DRAWN BY.• BRIAN CLARK ISSUE DATE.SCALE.• 412112020 AS NOTED JOB NO. 20-003 SHEET VT-03 SHT 10 OF 14 00467400000300 NE 1/4, SEC 30, TWP 27N, RGE 4E, W.M. SP #2-2007-57 1 #20100 275002 II II I 1 2 II I li i I I� I I I I r I SP #2-2007-58 l I #201007275001 I I I I l I 1 �► ---� I � I I I I / � I II 30' ; I I 00467400002701 ■ �\ i � � I II ROW — — — — — — N 89'06'47" W 128.01,�, I II o I 0 ao� 4 1 W� 004674000P0601 N PROPOSED TOWNHOUSES � 'v I 00467400002600 I a IN N 2 UNIT 1 UA UNIT 3 UNIT 4 O I I j 004674 0000600 I �1 I SANITARY SEWER, STORM DRAINAGE, WATER, CONCRETE CURB & GUTTER CONSTRUCTION & REMOVAL ZONE. LAND CLOSURE PER FIGURES I T=P6H-6 'SHOULDER WORK WITH MINOR I I I ENCROACHMENT (TA-6)" & 6H-10 "LANE CLOSURE ON TWO LANE ROAD USING FLAGGERS" (SEE DETAIL THIS SHEET) IN COE HANDOUT #E81 N 89'06'47_ " W 128.01' I I "TRAFFIC CONTROL REQUIREMENTS" I I i I I 30' HAWARDE TRACTS I I Row VOL. 14 AGE 69 I o r 'I I I , p� --_—_--� PARCEL I I W J i I oN i I 00467400002500 z ao I I I I I 00467400001100 I I I I I I � I I I I I PARCEL D LOT 11 I I 00467400000500 2 N SCALE. 1 " = 20' 0 10 20 40 TRAFFIC CONTROL NOTES 1. AFTER WORK WITHIN THE TRAVELED ROADWAY IS COMPLETED AT THE END OF EACH DAY, THE ROAD SHALL BE COMPLETELY OPEN TO TRAFFIC AND ALL EQUIPMENT SHALL BE OUT OF THE TRAVELED ROADWAY. ALL NONAPPLICABLE SIGNS SHALL BE REMOVED, TURNED OR COVERED DAILY WHEN CONDITION NO LONGER EXISTS. 2. ACCESS BY EMERGENCY VEHICLES SHALL BE MAINTAINED AT ALL TIMES. J. CONSTRUCTION SIGNS AND DELINEATORS SHALL BE PROVIDED AND MAINTAINED BY THE CON TRA C TOR. 4. TRAFFIC CONTROL PLAN IS SUBJECT TO CHANGE PRIOR TO CONSTRUCTION, HOWEVER, CITY APPROVAL IS REQUIRED. 5. ADDITIONAL SIGNING AND FLAGGING MAY BE REQUIRED AS CONDITIONS WARRANT 6. SHOULD A PROPOSED SIGN LOCATION FALL WITHIN A PRIVATE DRI VEWA Y, CONTRACTOR TO ADJUST LOCATION OF SIGN TO FALL 5'f BEYOND EDGE OF DRI VEWA Y IN DIRECTION OF ROAD TRAFFIC. (10' MAX. FROM PLAN LOCATION) DRI VEWA Y ACCESS SHALL BE MAINTAINED AT ALL TIMES. 7. ALL TRAFFIC CONTROL SHALL COMPLY WITH MUTCD STANDARDS (I.E. FIGURE 6H-6 AND 6H-10). 8. CLOSURE OF THE SIDEWALK AND PARKING AREAS FOR MORE THAN 72 HOURS WILL REQUIRE PAYMENT OF DISRUPTION FEES. 2009 Edition December 2009 Figure 61-1-6. Shoulder Work with Minor Encroachment (TA-6) OV3HV NHOM T avow A >IaLa"N avoa [_,� 3 JT MIN. i ILII" 1 Typical Application 6 i END ROAD WORK Note: See Tables 6H-2 and 6H-3 for the meaning of the symbols and/or letter codes used in this figure. Work vehicle Truck -mounted attenuator (optional) } Buffer space (optional) I 1/3 L 1 A ROAD i WORK AHEAD Page 645 Sect. 6H.01 2009 Edition Page 633 Table 61-1-2. Meaning of Symbols on Typical Application Diagrams ® Arrow board Shadow vehicle Arrow board support or trailer O O O (shown facing down) IN Sign (shown facing left) Changeable message sign or support trailer ® Surveyor Channelizing device 0 Temporary barrier ® Crash cushion ® Temporary barrier with warning light Direction of temporary traffic detour Traffic or pedestrian signal Direction of traffic Illllr� Flagger ® Truck -mounted attenuator ® Type 3 barricade High-level warning device (Flag tree) Warning light 0 Longitudinal channelizing device Work space 4UP -----0 Luminaire \`\\\ Pavement markings that should be o Work vehicle removed for a long-term project Table 61-1-3. Meaning of Letter Codes on Typical Application Diagrams Speed category to be determined by highway agency " The column headings A, B, and C are the dimensions shown in Figures 6H-1 through 6H-46. The A dimension is the distance from the transition or point of restriction to the first sign. The B dimension is the distance between the first and second signs. The C dimension is the distance between the second and third signs. (The "first sign" is the sign in a three -sign series that is closest to the TTC zone. The "third sign" is the sign that is furthest upstream from the TTC zone.) Table 6H-4. Formulas for Determining Taper Length Speed (S) Taper Length (L) in feet WSz 40 mph or less L = 60 45 mph or more L = WS Where: L = taper length in feet W — width of offset in feet S = posted speed limit, or off-peak 85th-percentile speed prior to work starting, or the anticipated operating speed in mph December 2009 Sect. 6H.01 Road Type Distance Between Signs" A B C Urban (low speed)' 100 feet 100 feet 100 feet Urban (high speed)` 350 feet 350 feet 350 feet Rural 500 feet 500 feet 500 feet Expressway /Freeway 1,000 feet 1,500 feet 2,640 feet 2009 Edition Page 653 Figure 6H-10. Lane Closure on aTwo-Lane Road Using Flaggers (TA-10) December 2009 Note: See Tables 6H-2 and 6H-3 for the meaning of the symbols and/or letter codes used in this figure. >Iaoln avow � ON3 / (optional) 50 to 100 ft 50 to 100 ft (optional) C ROA[ woRr \zn Typical Application 10 tied- nl LUI RAM ENGINEERING, INC. Civil Engineering / Land Planning 16531 13TH AVE W, SUITE A108 LYNNWOOD, WA 98037 PHONE: (425) 678-6960 WWW.RAMENGINEERINGINC.COM > m � � U 0 0 ��© o WA k i0 d 38608 \� EGISTEg��� IONe 1. LOT 1: LOT 2: LOT J. LOT 4: PL NZO2O-0029 21228 82ND PL W 21226 82ND PL W 21224 82ND PL W 21222 82ND PL W (BLD2020-0687) (BLD2020— 0689) (BLD2020-0688) (BLD2020-0690) ENGINEER. - ROB L. LONG, PE DRAWN B Y.• BR/AN CLARK /cSUE DATE• SCALE• 4/21/2020 AS NOTED CITY OF EDMONDS JOB No: 20-003 DATE: SHEET.- TC-01 BY: CITY ENGINEERING DIVISION SHT " OF 14 �{ 5-1/2" R=1/2" I iv ILR= " TTER 4 4 a 2' MIN SAWCUT SEE NOTE 10 J 4"-5/8 18" STANDARD 6"-5/8" MINUS CSTC SEE NOTE 11 MINUS CSBC I � STANDARD TYPE "A" CURB/GUTTER (NOT TO SCALE) HMA 4" OR MATCH EXISTING, WHICHEVER IS GREATER SEE NOTE 12 NOTES: 1. CITY INSPECTION REQUIRED ON FORM WORK PRIOR TO POUR. 2. FORMS SHALL BE TRUE TO LINE AND GRADE AND SECURELY STAKED. 3. EXPANSION JOINTS SHALL BE PLACED ADJACENT TO ANY STRUCTURE. 4. EXPANSION JOINTS SHALL BE EVERY 10 FEET. 5. EXPANSION JOINTS SHALL HAVE 1/2" TO 5/8" WIDE PREMOLDED JOINT FILLER. 6. CONCRETE SHALL BE CLASS 3000. 7. FINISH SHALL BE LIGHT BROOM. 8. CURB SHALL BE SPRAYED WITH CLEAR CURING COMPOUND OR SHALL BE COVERED AND KEPT MOIST FOR 72 HOURS. 9. REMOVAL/REPLACEMENT OF CONCRETE CURB SHALL BE FROM EXPANSION TO EXPANSION JOINT, UNLESS OTHERWISE DIRECTED BY CITY ENGINEER. 10. A 2-FT MINIMUM ASPHALT SAWCUT MAY BE REQUIRED AS DETERMINED BY CITY ENGINEER. 11. CURB/GUTTER SHALL BE 18" OR AS DIRECTED BY CITY ENGINEER. 12. ALL VERTICAL EDGES SHALL BE TACKED. 13. NATIVE AND GRAVEL SUBGRADE SHALL BE COMPACTED TO A MINIMUM OF 95% MAX DENSITY. REVISION DATE CITY OF EDMONDS CONCRETE CURB OCTOBER 2018 AND GUTTER PUBLIC WORKS STANDARD DEPARTMENT DETAIL APPROVED BY: R. ENGLISH T R- 5 2 0 9802 NOTES: * THE ADDRESS NUMBERS SHOULD BE 3" HIGH REFLECTIVE WHITE VINYL SET ON A ENGINEERING GREEN VINYL BACKGROUND. * ADDRESS SIGN REQUIRED WHEN ADDRESS CAN NOT BE SEEN FROM THE STREET AND PLACED ON 4"x4" TREATED WOOD POST. (SIGN TO BE PRODUCED BY CITY) * HEIGHT TO BOTTOM OF SIGN SHALL BE 30". 12" MIN R=1.0" (TYP) :KET (ZUMAR 850 LONG I SERIES OR EQUAL) (ZUMAR 850 LONG LUUK SERIES OR EQUAL) 2 001GSt FSW B Ir I D (TYP) J E (TYP) A* I C (TYP) r i SIGN TYPE A B C D E F G POST MOUNTED 25 & 30 MPH 30" MIN 6" .5" 1.5" 1.5" MIN 4" C 6" C MOUNTED 35 MPH VAR 9" .5" 2.5" 4" MIN 4.5" C 6" C MOUNTED STATE ROUTE VAR 9" .5" 2.5" 5.3" MIN 6" C 8" C OVERHEAD(SIGNAL MAST ARMS) VAR 16" .5" 3.5" 6" MIN 9" C 12" C NOTES: 1. MATERIAL - .080 FLAT ALUMINUM ROUNDED CORNERS WITH HIGH INTENSITY/PRISMATIC DIAMOND GRADE SHEETING. 2. COLOR - GREEN BACKGROUND WITH WHITE LETTERS, NUMBERS AND BORDER ON BOTH SIDES OF THE SIGN. 3. TEXT SHALL BE FHWA D SERIES FONT AND LAID OUT AS PER THE STANDARD HIGHWAY SIGNS AND MARKING (SHSM) BOOK. 3. ALL LETTERING SHALL BE COMPOSED OF UPPER AND LOWER CASE LETTERS. 4. ALL MOUNTED SIGNS FACING TRAFFIC ON 35 MPH STREETS SHALL HAVE THE NAME OF THE STREET IN 6" LETTERING. 5. ALL MOUNTED SIGNS FACING TRAFFIC ON STATE ROUTE SHALL HAVE THE NAME OF THE STREET IN 6" LETTERING INCLUDING, TYPE ABBREVIATED AS (ST, AVE, DR, PL, WAY, CIR, ETC) AND GEOGRAPHIC DELINEATORS (W AND SW). 6. ALL OVERHEAD MOUNTED (TRAFFIC SIGNAL MAST ARMS) SIGNS SHALL HAVE THE NAME OF THE STREET IN 12" LETTERING. * VARIABLE LENGTHS REQUIRED FOR NAMED STREETS. REVISION DATE CITY OF EDMONDS STREET NAME SIGN AND OCTOBER 2018 FIRE -AID ADDRESS AND PUBLIC WORKS POST MOUNTING DETAIL STANDARD DEPARTMENT DETAIL APPROVED BY: R. ENGLISH T R- 5 7 0 U o� m� �o j I 0 E� I rch 3 o� o� N o 0 I co o X > � pro. NZ2 NE 1/4, SEC 30, TWP 27N, RGE 4E, W.M. CVIIA AICIlIAI I - - 1 nl I\111V PLAN VIEW (NOT TO SCALE) 5' MIN FULL DEPTH 1/2" EXPANSION CURB/GUTTER JOINT MATERIAL SEE COESTD DTL TR-R-520 _ 2% MAX a ° d aa a as a as a as a c 47 a � ng: _a �o� �a ����� ��� 2" MIN 5/8" MINUS CSTC ON NATIVE BEARING SOIL SECTION VIEW SEE NOTE 9 NOTES: (NOT TO SCALE) 1. CITY INSPECTION REQUIRED ON FORM WORK PRIOR TO POUR. 2. CONCRETE SHALL BE CLASS 3000. 3. FINISH SHALL BE LIGHT BROOM. 4. SIDEWALK THICKNESS SHALL BE 4". 5. SIDEWALK THICKNESS AT DRIVEWAYS SHALL BE 6" THICK. 6. CURB AND GUTTER SHALL BE POURED SEPARATELY FROM SIDEWALK. 7. LIDS FOR JUNCTION BOXES AND UTILITY VAULTS SHALL BE NON-SKID AS SPECIFIED BY ENGINEER. 8. SEE COE STD DTL TR-550 FOR POSSIBLE ROOT BARRIER INSTALLATION. 9. SUBGRADE SHALL BE COMPACTED TO 95% MAXIMUM DENSITY. 10. ALL EDGES WITH EXPANSION JOINTS SHALL HAVE RADIUS CITY OF EDMONDS CONCRETE SIDEWALK PUBLIC WORKS DEPARTMENT APPROVED BY: R. ENGLISH 0 0 0 0 0 3"� ° 0 / 0 GROUND SURFACE "� \// o ° //\ j g" ° a /\\ 2 3 04 ° ° 8 . \ ANCHOR SQUARE //j 2.5"x2.5" OD, 7 GAUGE, 24" LENGTH n 2 CUBIC FT SQUARE METAL CONCRETE POST �St. 189v 1 MP1, Z•i REVISION DATE JUNE 2019 STAN DAR D DETAIL TR-531 NOTES: SIGN POST: OSIGN POST SHALL BE 2"x2" SQUARE STEEL POSTS, MINIMUM 14 GAUGE, WITH 7/16" DIE -PUNCHED KNOCKOUTS ON 1" CENTERS FULL LENGTH FOUR SIDES COMPLYING W/ ASTM SPEC A653 AND BE HOT DIPPED GALVANIZED. O ANCHOR SHALL BE 2.25"x2.25" OD SQUARE STEEL, MINIMUM 14 GAUGE WITH 7/16" DIE PUNCHED KNOCKOUTS ON 1" CENTER COMPLYING WITH ASTM SPEC. A653 AND BE HOT DIPPED GALVANIZED. ANCHOR SHALL HAVE MINIMUM OF 3 HOLES ABOVE GRADE. ANCHOR SHALL HAVE TAPE INSTALLED ON BOTTOM 9 AS WELL AS ALL SIDES TO KEEP INSIDE CLEAR OF ALL MATERIAL. 04 INSTALL TWO DRIVE RIVETS ZUMAR INDUSTRIES #TL3806 OR EQUIVALENT OINSTALL TWO CORNER BOLTS AND NUTS ZUMAR INDUSTRIES #TL070 OR EQUIVALENT O 4"x4" WOODEN PRESSURE TREATED POST MAY BE USED WHEN POST IS MORE THAN 10' FROM EDGE OF TRAVEL LANE (OR APPROVED BY ENGINEER). SIGN INSTALLATION: SEE TRAFFIC STREET SIGN DETAIL TR-575 FOR GUIDANCE ON SIGN INSTALLATIONS. REVISION DATE CITY OF EDMONDS SIGN POST INSTALLATION OCTOBER 2018 IN NON -SIDEWALK AREA PUBLIC WORKS STANDARD DEPARTMENT DETAIL APPROVED BY: R. ENGLISH T R - 5 71 pRop �'qY FR MqT O Og FG N N OF pR�VeW PROVep eR�VATE � Mg39 qY qT RO C/>Y P �� pERTY GENE EXPANSION EXPANSION �P� JOINT JOINT SEE DRIVEWAY 24' CURB 30'M (?NT/q4 TRANSITIONAL 1%( Cq 'ylN/,y DETAIL BELOW (c044M 4Rq f) DRIVEWAY APPROACH 4) CONCRETE CURB AND GUTTER, SEE / O COE STD DTL TR-520 6' TYP \ EXISTING PAVEMENT FULL DEPTH MAX 15'` 1/2" EXPANSION 2' MIN JOINT I SAWCUT 7 8 39, MAX O 2% MAX 6" CURB LOPE 7 ... - 3 2 } SECTION A -A DRIVEWAY CURB TRANSITIONAL DETAIL FOR CURB AND GUTTER OR VERTICAL CURBS NOTES: (DCURB AND GUTTER SHALL BE POURED SEPARATELY FROM THE SIDEWALK. CITY INSPECTION REQUIRED ON FORM WORK PRIOR TO POUR. 02 DRIVEWAY APRON INCLUDING WING RAMPS SHALL BE A MINIMUM OF 6" THICK AND SHALL BE PLACED ON 2" OF 5/8" CSTC COMPACTED TO 95% MAXIMUM DENSITY. 03 SUBGRADE SHALL BE COMPACTED TO 95% MAXIMUM DENSITY. 4O 2' ASPHALT SAWCUT MAY BE REQUIRED WITH CURB/GUTTER INSTALLATION. REFER TO COE STD DTL TR-520. 05 CONCRETE SHALL BE CLASS 3000. 06 CURB TRANSITION SHOULD MAINTAIN A SLOPE NO GREATER THAN 8.3%. IF THE SLOPE REQUIREMENT CANNOT BE ACHIEVED, MAXIMUM CURB THE TRANSITION LENGTH SHALL BE 15-FEET. 07 MAINTAIN 1/2" LIP AT GUTTER. 08 IF DRIVEWAY WIDTH EXCEEDS 15', INSTALL A FULL DEPTH EXPANSION JOINT AT CENTER OF DRIVEWAY. 09 INSTALL MINIMUM 5-FT TRANSITION PANEL BETWEEN DRIVEWAYS AND WHEN CONNECTING TO EXISTING SIDEWALK. 10 FINISH SHALL BE LIGHT BROOM. REVISION DATE CITY OF EDMONDS DRIVEWAY APPROACH JANUARY 2018 TYPE PUBLIC WORKS STANDARD DEPARTMENT DETAIL FSt. 189� APPROVED BY: R. ENGLISH TR-541 U) CONCRETE SIDEWALK SEE COE STD DTL TR-531 CURB 5'-0" MIN 1'-0" 3 zx mm PLANTER STRIP (0 o WIDTH VARIABLE 4 I 1 ih � FILL AND COMPACT WITH SAND (TOP 4" SAND, BOTTOM 32' CSTC) CONCRETE SIDEWALK 111 1* ° .d °; 8" PVC SLEEVE THROUGH SIDEWALK oL 36" GRADE I TO BOTTOM OF SLEEVE SET SLEEVE IN CSTC 30" GRADE TO BOTTOM OF POST NOTES: 01 LOCATION OF MAILBOX WITHIN THE RIGHT-OF-WAY SHALL BE APPROVED BY THE CITY. 02 MAILBOXES AND LOCK BOXES SHALL COMPLY WITH USPS REGULATIONS. 03 POST GIVING FIRM SUPPORT BUT NOT TO EXCEED 4x4 WOODEN POST (TREATED). 04 FOR MAILBOXES PLACED WITHIN PLANTER STRIP, FOLLOW COE STD DTL TR-582. `St. 189" REVISION DATE CITY OF EDMONDS MAILBOX JANUARY 2018 DETAIL 1 PUBLIC WORKS STANDARD DEPARTMENT DETAIL APPROVED BY: R. ENGLISH TR-580 c� z Y a 0 z I w 5 w 0 Z y m C) J a a m D a V U p o U) 12" MIN W A 2" STROKE 55 m z PAINTED m STRIPING O z 0 D z c•> 20' MIN OO -4" PERIMETER STRIPING (TO BE 6" OFFSET FROM CURB OR EDGE OF PAVEMENT 12" MIN NO PARKING ANY TIME FIRE LANE * THE USE OF SIGNS REQUIRES FIRE MARSHAL APPROVAL NOTES: O FIRE LANE MUST MEET ALL MINIMUM CITY OF EDMONDS DRIVEWAY/ACCESS STANDARDS AND SOUTH SNOHOMISH COUNTY REGIONAL FIRE AUTHORITY'S (SSCRFA) FIRE LANE STANDARD. 02 FIRE LANE SHALL MAINTAIN AN UNOBSTRUCTED MINIMUM WIDTH OF 20' UNLESS APPROVED BY THE FIRE MARSHAL. 03 FIRE LANE TO BE ASPHALT OR APPROVED EQUIVALENT. O FIRE LANE SHALL MAINTAIN AN UNOBSTRUCTED MINIMUM VERTICAL CLEARANCE OF 13.5'. O FIRE LANE SHALL NOT HAVE A GRADE EXCEEDING 12% UNLESS APPROVED BY SSCRFA. O PAINTED STRIPING SHALL BE YELLOW IN COLOR. O REFER ALSO TO CITY OF EDMONDS AND SSCRFA FIRE LANE STANDARD FOR CIRCULATION AND TURN-AROUNDS. REVISION DATE FIRE LANE SPECIFICATIONS JANUARY 2018 CITY OF EDMONDS (MULTI -FAMILY AND PUBLIC WORKS COMMERCIAL) STANDARD DEPARTMENT DETAIL FSt 189� APPROVED BY: R. ENGLISH TR-567 RAM ENGINEERING, INC. Civil Engineering / Land Planning 16531 13TH AVE W, SUITE A108 LYNNWOOD, WA 98037 PHONE: (425) 678-6960 WWW.RAMENGINEERINGINC.COM O O CL U O Z Z cc g O O � U W 2 U J cc o � J O IAJ Q � 0 x O M0© Z V) 2' 2' 2' ft2' 2' ft2' EXCAVATED AREA EXCAVATED AREA 2' 2' 2' 2' PARKING 2° LANE LvxcAREA 77 PARKING LANE CRACKS EXISTING PATCH LESS THAN 5' WIDE RESTORATION LIMIT EXCAVATED AREA NOTES: 1. REPAIR AREA MAY BE MODIFIED WITH WRITTEN APPROVAL BY CITY DEPENDING ON CONDITIONS OR SCHEDULED CONSTRUCTION MAINTENANCE 2. ADJUST ALL UTILITY CASTINGS TO FINISHED GRADE AND RESTORE ALL EXISTING SURFACE IMPROVEMENTS INCLUDING STRIPING, SIGNAGE, AND OTHER MARKINGS OR DELINEATORS. REVISION DATE CITY OF EDMONDS ASPHALT REPAIR SOMETHING 2o,s �_ PUBLIC WORKS STANDARD DEPARTMENT DETAIL Fs t 189 APPROVED BY: R. ENGLISH T R- 5 9 2 Know what's below. Call before you dig, R- L 0- of Wasx0'�% d O 38508 w �GISTE4t� �IONAL PLN2020-0029 ENGINEER: LOT 1: L 0 T 2: 21228 21226 82ND 82ND PL PL W W (BLD2020-0687) (BLD2020- 0689) ROB L. LONG, PE DRA WN B Y.• LOT J. 21224 82ND PL W (BLD2020-0688) BRIAN CLARK LOT 4: 21222 82ND PL W (BLD2020-0690) ICSUE DATE SCALE 412112020 AS NOTED CITY OF EDMONDS ✓oe No: 20-003 DATE: SHEET DT-01 BY- CITY ENGINEERING DIVISION SHT 12 DF 14 LO Ul 6" MIN Uj w 6" MIN 8" MIN 8" MIN NOTE SEE COE STD DTL GU-410 BEDDING MATERIAL (5/8" MINUS) CRUSHED PER COE MOD 9-03.16.A.2 OR SUITABLE EXCAVATED MATERIAL AS APPROVED BY CITY ENGINEER (SEE NOTE 2 BELOW) FOUNDATION (IF REQUIRED) SEE NOTE 4 NOTES: 1. MAXIMUM WIDTH OF TRENCH AT TOP OF PIPE • 36" FOR PIPE UP TO AND INCLUDING 12" DIAMETER O.D. PLUS 18" FOR PIPE LARGER THAN 12" NOMINAL DIAMETER 2. REFER TO CITY OF EDMONDS MODIFICATIONS TO DIVISION 9 OF WSDOT STANDARD SPECIFICATIONS FOR MATERIAL GRADATION AND ADDITIONAL INFORMATION. 3. TRENCH BACKFILL SHALL MEET A MINIMUM COMPACTION OF 95% DENSITY PER ASTM D 1557. 4. IF UNSTABLE MATERIAL IS ENCOUNTERED BELOW PIPE ZONE, CONTRACTOR SHALL REMOVE AND REPLACE AS REQUIRED BY CITY ENGINEER. `St. 18`�- REVISION DATE CITY OF EDMONDS JANUARY 2018 TYPICAL TRENCH SECTION PUBLIC WORKS STANDARD DEPARTMENT DETAIL APPROVED BY: R. ENGLISH GU-400 RING AND COVER PER COE STD DTL GU-420 FOR CURB AND SPLASH LINE ONLY: FRAME AND GRATE PER COE STD DTL SD-320 SERIES 8" MIN- 18" MAX HANDHOLDS (2) _ TOP SLAB SEE COE STD DTL GU-423 20"x24" OR 24" DIA ' 6" MAX d 12" (TYP)� 48", 54", 60", 72" OR 96" STEPS OR LADDERORIENT SO THAT THEY ° ARE NOT ABOVE PIPE SAND COLLAR OR II POLYPROPYLENE KOR-N-SEAL AROUND SAFETY STEP I PIPE 12" O.C. (TYP) (SEE NOTE 6) I = d Q < ° 2'-0" MIN 1 "-4" PRECAST BASE AND MAX . d..a d INTEGRAL RISER NOTES: 1. CATCH BASINS SHALL BE CONSTRUCTED IN ACCORDANCE WITH WSDOT STANDARD SPECIFICATION 9-05.50(3). 2. HANDHOLDS IN ADJUSTMENT SECTION SHALL HAVE 3" MIN CLEARANCE. STEPS IN CATCH BASIN SHALL HAVE 6" MIN CLEARANCE. 3. APPLY NON -SHRINK GROUT TO INSIDE AND OUTSIDE OF ALL JOINTS, RINGS, PICK HOLES, RISERS AND FRAMES. ALL PRECAST CONCRETE SHALL BE CLASS 4000. 4. KNOCKOUT OR CUTOUT HOLE SIZE SHALL EQUAL PIPE OUTER DIAMETER PLUS CATCH BASIN WALL THICKNESS. MAX HOLE SIZE SHALL BE 36" FOR 48" CATCH BASIN, 42" FOR 54" CB, 48" FOR 60" CB, 60" FOR 72" CB, 84" FOR 96" CB. MIN DISTANCE BETWEEN HOLES SHALL BE 8" FOR 48", 54", AND 60" CB; 12" FOR 72" AND 96" CB. 5. CATCH BASIN FRAMES AND GRATES OR COVERS SHALL BE IN ACCORDANCE WITH SEC 7.05 OF THE WSDOT STANDARD SPECIFICATIONS. 6. STEP AND LADDER MAY BE USED IN LIEU OF POLYPROPYLENE SAFETY STEPS. SEE COE STD DTL GU-423. REVISION DATE CITY OF EDMONDS CATCH BASIN, TYPE II OCTOBER 2018 48999 54"9 60", PUBLIC WORKS 72 & 96" STANDARD DEPARTMENT DETAIL APPROVED BY: R. ENGLISH S D- 3 0 0 NE 1/4, SEC 30, TWP 27N, RGE 4E, W.M. FINAL JOINT SHALL BE A NEAT STRAIGHT HMA CLASS 1/2" LINE. ALL EXPOSED VERTICAL EDGES SHALL PG 58H-22 BE TACKED NEATLY PER WSDOT STANDARD (SEE NOTES 4 & 5) 1' SPECIFICATIONS 5-04.3(5)A APPROVED TACK OR APPROVED EQUAL AND SEALED PER 1 WSDOT STD 5-04.3(5)C. SLOPE EXCAVATION TO AVOID UNDERMINING EXISTING PAVEMENT. EXISTING HMA EXISTINGi\��\�� a a4 MATERIAL CRUSHED SURFACE BASE IMPORT OR NATIVE MATERIAL BACKFILL SHALL BE COMPACTED COURSE PER WSDOT STD TO 95% MAXIMUM DENSITY SPEC 9-03.9(3) (SEE NOTE 2) (SEE NOTE 3) TRENCH WIDTH NOTES: 1. SEE CITY OF EDMONDS MODIFICATIONS TO DIVISION 9 OF THE CURRENT WSDOT STANDARD SPECIFICATIONS FOR BACKFILLING REQUIREMENTS. 2. SUBMIT PROCTOR AND DENSITY TESTS FROM CERTIFIED TESTING COMPANIES DOCUMENTING THAT THE BACKFILL MEETS A MINIMUM OF 95% DENSITY PER ASTM D 1557. 3. CSBC DEPTH SHALL BE A MINIMUM 6" OR MATCH EXISTING WHICHEVER IS GREATER. WHEN MATCHING EXISTING CSBC DEPTH GREATER THEN 6", THEN CSBC SHALL BE INSTALLED IN MULTIPLE EQUAL THICKNESS LIFTS NOT EXCEEDING 6". 4. ROADWAY HMA DEPTH SHALL BE A MINIMUM OF 4" THICK. UNLESS APPROVED BY THE ENGINEER, ANY DEPTH GREATER THAN 4" SHALL MATCH EXISTING. 5. ALLEY HMA DEPTH SHALL BE A MINIMUM OF 2" THICK. UNLESS APPROVED BY THE ENGINEER, ANY DEPTH GREATER THAN 2" SHALL MATCH EXISTING. 6. UNLESS APPROVED BY THE ENGINEER, THE HMA SHALL BE INSTALLED IN MULTIPLE EQUAL THICKNESS LIFTS NOT EXCEEDING 2". 7. FINAL PAVEMENT JOINTS SHALL BE NEATLY AND UNIFORMILY SEALED WITH WSDOT STANDARD SPECIFICATIONS 5-04.3(5)C APPROVED JOINT SEALANT OR APPROVED EQUAL. REVISION DATE CITY OF EDMONDS TYPICAL HMA AND FEBRUARY 2020 UTILITY PATCH PUBLIC WORKS STANDARD DEPARTMENT DETAIL APPROVED BY: R. ENGLISH G U - 41 0 FLOW CONTROL 4.5" STRUCTURE - PVC PIPE* NON -SHRINK GROUT V-0" MAX CONTROL DEVICE ASSEMBLY TO BE COUPLING PVC PIPE REMOVABLE FROM (OPTIONAL) STUB* I INSIDE THE FCS SET SCREW TO PREVENT ROTATION J� INVERT* GASKET TYP (TYP) < I PVC PIPE PVC ADAPTER* W/ CROSS* 0 DOUBLE GASKET I I AND ADHESIVE BONDED SAND FINISH ON EXTERIOR. MIN 7" LONG DRILLED ORIFICE IN PVC INSIDE CAULK SPACE BETWEEN CAP PLUG PVC ADAPTER AND PIPE STUB CONNECTION & CONTROL DEVICE ORIFICE DIAMETER* DETAIL A CONNECTION AND 0' LADDER OR HAND HOLDS CONTROL DEVICE POLYPROPYLENE (SEE DETAIL A) OUTLET PIPE / ALLOWABLE OUTLET LOCATION (180' to 315') FINISHED GRADE V-NOTCH WEIR AS NEEDED � , SUPPORT (2 REQ'D) CONTROL DEVICE SEE DETAIL A N EL* / PVC PIPE* TEE* SPOOL* ELBOW* DRILLED J ORIFICE DIA* PVC INSIDE CAP PLUG* CATCH BASIN FLOW CONTROL STRUCTURE SHOWN W/ TYPE 2 CATCH BASIN (DETAILS A & B SHALL APPLY TO ALL DESIGNS NOTES: WHERE A SHEAR GATE WOULD OTHERWISE APPLY) * SPECIFIC DESIGN INFORMATION AS INDICATED ON APPROVED CONSTRUCTION DRAWINGS. INVERT OF DETENTION PIPE IN STRUCTURE SHALL BE EQUAL TO OR HIGHER THAN THE INVERT OF THE OUTLET PIPE. PRIVATELY -OWNED CONTROL STRUCTURES SHALL NOT BE PLACED IN CITY RIGHT-OF-WAY. REVISION DATE CITY OF EDMONDS FLOW CONTROL JANUARY 2018 STRUCTURE 7 PUBLIC WORKS (FCS) STANDARD DEPARTMENT DETAIL APPROVED BY: R. ENGLISH S D - 3 01 HARP FACE GOTHIC NOTE 1 FOR WORDING BOTTOM VIEW 3 PLCS EQUALLY SPACED 120' APART ON 23-1/16" DIA BC RING AND COVER (3) BLT SOC (ALLEN HEAD) 5/8"-1 1 x 1.5 SS 25" DIA �I 1-J COVER SECTION EON BOLTING DETAIL 26-1/2" DIA 25-1/4" DIA 1-1/16" NOTES: 1. COVER SHALL HAVE THE WORD "SEWER" FOR -578 SANITARY SEWER MANHOLES AND "STORM" OR �j-�'- "DRAIN" FOR STORM MANHOLES. 23-3/8" DIA CL OPEN 2. RING AND COVER SHALL BE RATED HS-20. 3. EAST JORDAN IRON WORKS 00371584 OR 27-5/16" DIA APPROVED EQUAL. 34-1/8" DIA 4. RING AND COVER IS CAST IRON, ASTM-48 CLASS 35. FRAME SECTION CITY OF EDMONDS PUBLIC WORKS DEPARTMENT `St. 18`�- SEE APPLICABLE STANDARD DETAILS FRAME AND GRATE REVISION DATE 24" MANHOLE APRIL 2018 CATCH BASIN RING AND COVER STANDARD DETAIL APPROVED BY: R. ENGLISH GU-420 PIPE ALLOWANCES PIPE MATERIAL MAXIMUM INSIDE DIAMETER REINFORCED OR 12" PLAIN CONCRETE ALL METAL PIPE 15" CPSSP* 12" (WSDOT STD SPEC 9-05.20) SOLID WALL PVC 15" (WSDOT STD SPEC 9-05.12.(1)) PROFILE WALL PVC 15" (WSDOT STD SPEC 9-05.12(2)) 5 S4 3p4 Ib` 2� * CORRUGATED POLYETHYLENE S4 STORM SEWER PIPE \2", 4", 6", OR 12" TI NOTES: RISER SECTION 1. CATCH BASINS SHALL BE CONSTRUCTED IN ACCORDANCE WITH WSDOT STANDARD SPECIFICATION 9-05.50(3). 2. AS AN ACCEPTABLE ALTERNATIVE TO REBAR, WELDED WIRE FABRIC HAVING A MIN. AREA OF 0.12 SQUARE INCHES PER FOOT MAY BE USED. WELDED WIRE FABRIC SHALL COMPLY 224 TO ASTM A497 (AASHTO M 221). WIRE FABRIC SHALL NOT BE PLACED IN KNOCKOUTS. 4 4 3. APPLY NON -SHRINK GROUT TO INSIDE AND OUTSIDE OF p° ALL JOINTS, RINGS, RISERS AND FRAMES. �\ 4. ROUND KNOCKOUTS MAY BE ON ALL 4 SIDES, WITH MAX / DIAMETER OF 20". KNOCKOUTS MAY BE EITHER ROUND OR "D" SHAPE. 0 P1 5. THE MAX DEPTH FROM THE FINISHED GRADE TO THE PIPE INVERT IS 5'-0". v 6. THE TAPER ON THE SIDES OF THE PRECAST BASE SECTION AND RISER SECTION SHALL NOT EXCEED 1/2"/FT. 7. CATCH BASIN FRAME AND GRATE SHALL BE IN ACCORDANCE WITH STANDARD SPECIFICATIONS. MATING SURFACES SHALL BE FINISHED TO ASSURE NON -ROCKING FIT WITH ANY COVER POSITION. (MEASUREMENT AT THE TOP OF THE BASE) 8. VERTICAL EDGE OF RISER SHALL NOT BE MORE THAN 2" PRECAST BASE SECTION FROM VERTICAL EDGE OF CATCH BASIN WALL. CITY OF EDMONDS PUBLIC WORKS DEPARTMENT CATCH BASIN TYPE APPROVED BY: R. ENGLISH REVISION DATE JANUARY 2018 STANDARD DETAIL SD-303 6-1/2" MIN HANDHOLD LADDER TO _ HANG FROM MH STEP I WALL y SUPPORT (TYP) I I I I 2 I 0 - -{ 5.5" I 1'-O" MAX- a a _ PREFABRICATED LADDER r 9-3/8" FOR BLOCK OR co Lr BRICK MH SECTION 9-1/2" FOR PRECAST MH SECTION (4" FOR 7" FOR MODIFIED STEP FOR MODIFIED PRECAST MH SECTION 1�1-1 "�I STEP) STEP NOTES: _1YLENE 1. LADDER MAY BE INSTALLED IN ALL STEP CATCH BASINS AND MANHOLES WHEN DEPTH OF STRUCTURE FROM TOP OF FRAME TO LOWEST FLOWLINE EXCEEDS FOUR(4) FEET. 2. DIMENSIONS FOR THE MH LADDER AND STEP ARE MINIMUM REQUIREMENTS ONLY. 3.STEPS AND HANDHOLDS SHALL BE INSTALLED AT 1'-0" ON CENTER SPACING. WHEN THE DISTANCE FROM THE HIGHEST STEP OR HANDHOLD AT THE TOP OF THE MH FRAME EXCEEDS V-0" AND ANOTHER STEP OR HANDHOLD CANNOT BE INSTALLED BECAUSE OF THE LOCATION OF THE MH FRAME, A HANDHOLD SHALL BE INSTALLED BETWEEN THE TOP 2 LAYERS OF BRICK OR COLLAR. 4. IF BOTH STEPS AND LADDER ARE REQUIRED IN ANY STRUCTURE, THEY SHALL BE FROM THE SAME MANUFACTURER. 5.STEPS AND LADDER SHALL BE POLYPROPYLENE AND CONFORM TO ASTM D4101 WITH 1 /2" ASTM A615 GRADE 60 STEEL REINFORCING BAR. LANE P-13938, M.A.PS2-PF, OR EQUAL. 6. FASTEN LADDER TO FLOOR AND WALL SUPPORTS WITH 1-1/2" x 3-3/4" ANCHORS. ANCHORS TO BE INSTALLED PER MANUFACTURER RECOMMENDATIONS. REVISION DATE CITY OF EDMONDS JANUARY 2018 STEP AND LADDER DETAIL PUBLIC WORKS STANDARD DEPARTMENT DETAIL APPROVED BY: R. ENGLISH GU-423 18"x24" (+1 /32", -0" TYP �9/16" 1-1/2" 4" 16"x22" OPENING 3/4" 17-3/4"x23-3/4" +1 32 -0 TYP 25" SECTION A -A 25" 7-7/8" I� r----� I 2-1 /2„ 1 CEMENT CONCRETE CURB PAVEMENT, DEPTH VARIES 1 3 - `' Y \\ GUTTER ::: \� :. L-- �:--------.' PRECAST �`• �:. �::" , � CONCRETE RISERS \� CATCH BASIN f � WALL SECTION B-B VERTICAL CURB OR CURB AND GUTTER B� PLANTING STRIP OR SIDEWALK 1 /2 TA w w A �rWZ �ocyz �oow CONCRETE Q of M GUTTER U m N - z�Q \ O V m SEE o NOTE 1 ' 1 w -vow 3/4" a U o U_ _ Q - 0 -:SEE NOTE 6':::: LEVEL PAD 16 3 4" x 2-1/4" x 1 8" PLAN B � PLAN NOTES: 1. DRILL AND TAP FOR, AND PROVIDE, TWO LOCKING BOLTS 5/8"-11 NC STAINLESS TYPE 304 STEEL SOCKET HEAD (ALLEN HEAD) BOLTS, 2" LONG. 2. FRAME MATERIAL IS CAST IRON PER ASTM A48 CLASS 30 OR BETTER. 3. SET FRAME TO GRADE AND CONSTRUCT ROAD AND GUTTER TO BE FLUSH WITH FRAME. 4. MATCH CENTERLINE OF CATCH BASIN TO CURB LINE FOR TYPE 1 AND 1-L. 5. VANED GRATE SHALL BE INSTALLED ON CONTINUOUS ROAD SLOPES. HERRINGBONE GRATES SHALL BE INSTALLED IN ALL SAGS AND SUMPS. 6. CURB/CURB AND GUTTER AS REQUIRED BY THE CITY ENGINEER. REVISION DATE CITY OF EDMONDS STANDARD JANUARY 2018 FRAME INSTALLATION PUBLIC WORKS STANDARD DEPARTMENT DETAIL APPROVED BY: R. ENGLISH SD-320 Know what's below. Call before you dig, ENGINEERING, INC. Civil Engineering / Land Planning RAM 16531 13TH AVE W, SUITE A108 LYNNWOOD, WA 98037 PHONE: (425) 678-6960 WWW.RAMENGINEERINGINC.COM O O_ U O Z W m g O O � U W ~ 2 U J cc 0 J O 1-4 Q � 0 O 11) M0© �o , i� x d O 38508 9 - �GISTE� G IO>\reT . PLN2020-0029 ENGINEER: //////�f/�r% Z to Z Z 15 LOT 1: L 0 T 2: 21228 21226 82ND 82ND PL PL W W (BLD2020-0687) (BLD2020- 0689) ROB L. LONG, PE DRA WN B Y.- LOT 3: 21224 82ND PL W (BLD2020-0688) BRIAN CLARK LOT 4: 21222 82ND PL W (BLD2020-0690) ICSUE DATE SCALE 412112020 AS NOTED CITY OF EDMONDS ✓oe No: 20-003 DATE: SHEET DT-02 BY - CITY CITY ENGINEERING DIVISION 73 OF / 4 SHT r 11 LEVELING PAD FOR SLOT DETAIL 1/8" x 3/4" x 2-1/4" SEE COE STD DTL SD-324 (6 MIN) -1 /2" 23-3/4" PLAN 5' DRAFT ELEVATION „J 1/t6 NOTES: 1. USE WITH TWO LOCKING BOLTS 5/8"-11 NC STAINLESS TYPE 304 STEEL SOCKET HEAD (ALLEN HEAD) BOLTS, 2" LONG. NOTE SLOT DETAIL. 2. MATERIAL IS DUCTILE IRON ASTM A536 GRADE 80-55-06. 3. "OUTFALL TO STREAM DUMP NO POLLUTANTS" IN RAISED LETTERS SHALL BE LOCATED ON GRATE AS SHOWN, BORDER AREA. 4. SHALL CONFORM TO SEC. 7.05 OF THE WSDOT STANDARD SPECIFICATIONS. 5. WELDING IS NOT PERMITTED. 6. USE IN CONTINUOUS SLOPE CONDITIONS ONLY. 7. EDGES SHALL HAVE 0.125" RADIUS, 0.125" CHAMBER OR COMPLETE DEBURRING. 8. USE A THROUGH CURB INLET WITH HERRINGBONE GRATE IN SAG VERTICAL CURVES PER COE STD DTL SD-324. REVISION DATE CITY OF EDMONDS JANUARY 2018 VANED GRATE PUBLIC WORKS STANDARD DEPARTMENT DETAIL APPROVED BY: R. ENGLISH S D - 323 w z J RESIDENCE a Of -� CLEANOUT a WITH 45' BEND AND 2' CAP CLEANOUT (MAX) f(TYP) NOT TO EXCEED 100' BETWEEN CLEANOUTS CLEANOUT (WYE WITH CAP AND CLEANOUT COVER) AND CONCRETE LEVELING COLLAR 2"± FINISHED GRADE z w bj Ld W N d Q o L�l W \ w a � ILI U 12" LOCKING COVER SEE NOTE 3 END OF PIPER GRIPPER PLUG (CHERNE 27061 OR APPROVED EQUAL) WATER TIGHT CAPS\\�� RISER LEVELING COLLAR 45' SEE NOTE 4 / 45' 12" PVC SLEEVE / 6" RISER 4" OR 6" SIDE SEWER 6" WYE AND 6" CITY STUB GENERAL CLEANOUT DETAIL 45' BEND 4" OR 6" 12" LOCKING COVER SIDE SEWER CLEANOUT DETAIL SEE NOTE 3 AT PROPERTY LINE/CITY EASEMENT w Of m LEVELING COLLAR NOTES: IL w o SEE NOTE 4 It E ASPHALT SURFACE 1. SEWER PIPE SHALL BE SDR-35 AND JOINTS SHALL BE _ GASKETED. 12"± I 2. PIPE SLOPE TO BE 2% MIN AND UP TO 50% MAX. 3. SEWER CLEANOUT COVER TO BE EAST JORDAN IRON WORKS 1 FOOT LONG 12" PVC PRODUCT #00366102 STAR PIPE COSP48L OR APPROVED SLEEVE EQUAL. 6" RISER END OF PIPE GRIPPER 4. LEVELING COLLAR SHALL BE CONSTRUCTED AS FOLLOWS: PLUG (CHERNE 270261 OR APPROVED EQUAL) • IN ROADWAYS PER COE STD DWG GU-424 TYPICAL CLEANOUT • IN SIDEWALK/LANDSCAPED AREAS, EITHER 24"x24%6" UNDER ASPHALT OR CONCRETE DEEP CONCRETE COLLAR OR 24" DIAMETER x 6" DEEP CONCRETE COLLAR `S1. 18y" U o� ao ° �o jc I C) EN N .c I � oa o� N O O I k > � NZZ REVISION DATE CITY OF EDMONDS JANUARY 2018 SEWER CLEANOUT DETAILS PUBLIC WORKS STANDARD DEPARTMENT DETAIL APPROVED BY: R. ENGLISH S S- 2 0 0 O 1-1/8" BAR (TYP) 7/8" SLOT (TYP) i FOUNDARY NAME 1/2" LETTERS RECESSED TO BE FLUSH THIS SIDE TO CURB O M I r ON dWf1 i mm s of TvAn N f 1-7/8"--- SEE DETAIL TOP VIEW BELOW NE 1/4, SEC 30, TWP 27N, RGE 4E, W.M. 7-1/4" FOR 11" MACHINING CLEARANCE THIS BAR 1" THICK (TYP, 4 PLACES) BARS 1-5/8" THICK THIS AREA BARS 1-3/8" -THICK THIS AREA LEVELING PADS 8-3/4" x 3/4" x 1 /8" BOTTOM VIEW 23-3/4" 1-3/8" j + II 17-3/4" r1-7/16" I r2-1/ 2" 2" 1 /16" _] 11 -3� } RR=7�1/ 44„ II // 1-3 4" [3/4" j �1-3 4" 23-1/2" 17-1/2" SIDE VIEW END VIEW r1_1/4" �3/4" } 04 ROUND e�,x 5/8" ELLIPTICAL - TANGENT BETWEEN TWO RADII SLOT DETAIL OPTIONAL DESIGN FOR SEE NOTE 1 GRATE OPENINGS ENDS NOTES: 1. SLOT FORMED AND RECESSED FOR 5/8"-11 NC X 2 SOCKET HEAD (ALLEN HEAD) BOLT. 2. GRATE SHALL BE DUCTILE IRON. 3. SHALL CONFORM TO SEC. 9-05.15 OF THE WSDOT STANDARD SPECIFICATIONS. 4. USE HERRINGBONE GRATE IN CURB LINE OF SAGS AND SUMPS. 5. USE FRAME SHOWN IN STANDARD DETAIL. `St. 18y" w z�w J 1 W z O? TWO_ ww o it I o Q U, Lnaa� W T Qom NOTES: REVISION DATE CITY OF EDMONDS PARKING LOT/ JANUARY 2018 AREA GRATE PUBLIC WORKS (HERRINGBONE) STANDARD DEPARTMENT DETAIL APPROVED BY: R. ENGLISH S D- 3 2 4 (IF STUB FOR FUTURE DEVELOPMENT) SEWER STUB SHALL BE LOCATED 10' INSIDE PROPERTY LINE & STAKED. PLACE 2 x 4 AT END OF SIDE SEWER STUB AND CUT TO LENGTH TO ENSURE 3 FEET EXTENDS ABOVE GRADE. PAINT TOP 18 INCHES WHITE. IN 3 INCH HIGH LETTERS, STENCIL THE NUMBER OF EVEN FEET FROM GROUND ELEVATION TO THE SEWER STUB INVERT. 8 GAUGE WIRE TO BE DOUBLE WRAPPED AROUND PIPE AND 2 x 4 STAKE AT OR ABOVE FINISHED GRADE. w z J w a LOCKING CLEANOUT COVER f PER COE STD DTL SS-200 6" LATERAL SEWER SLOPE - 2% MIN TO 50% MAX 22.5' OR 45' BEND 6" TEST TEE 6" WYE/6" ROMAC SADDLE SEE NOTES 1 AND 2 fPOSSIBLE SEWER MAIN LOCATION 22.5' OR 45' BEND 6" TEST TEE 6" TEE POSSIBLE I SEWER MAIN LOCATION 1. WHEN TAPPING INTO EXISTING MAIN A ROMAC STYLE CB SADDLE SHALL BE USED. PLACEMENT OF TEE SHALL DEPEND ON DEPTH OF SEWER MAIN. AS A MINIMUM, THE TEE SHALL BE PLACED AT A 45 DEGREE ANGLE FROM PIPE SPRINGLINE. 2. IF NEW MAIN IS BEING INSTALLED OR MAIN IS BEING REPLACED, SERVICE CONNECTION TO THE MAIN SHALL BE DONE WITH A WYE. WYE SHALL BE AT A 45 DEGREE ANGLE FROM PIPE SPRINGLINE. 3. IF CONNECTING EXISTING PRIVATE SIDE SEWER TO NEW CITY LATERAL, A CONCRETE/PVC STRONGBACK FERNCO RC SERIES OR ROMAC COUPLING SHALL BE USED AND SECURED PER MFR'S INSTRUCTIONS. 4. BORING OF SERVICES WITHIN RIGHT OF WAY IS NOT ALLOWED. 5. SEWER PIPE SHALL BE SDR-35 AND JOINTS SHALL BE GASKETED. 6. IF STUB FOR FUTURE DEVELOPMENT, USE RUBBER JOINT BISCUIT PLUG OR OTHER APPROVED WATERTIGHT PLUG. REVISION DATE CITY OF EDMONDS FEBRUARY 2018 NEW LATERAL SEWER 7 PUBLIC WORKS STANDARD DEPARTMENT DETAIL APPROVED BY: R. ENGLISH S S - 2 0 2 2.00 SPACING REF. 26.51±.250 0 0 0 0 0 0 0 0 0 0 0 O O O O o ° o 0 0 ° 0 ° 0 0 ° 0 0 ° 0 O O O O °°° ° 0 0° 0 0° ° 0° 0 0 0 o000000000 1 0 O O 000000000oi 0 O O O ° o 0 0 0 1 11 O O 0 o° 0° o° o° 0 11 0 O O O 0° o° o° o° 0 1 0 O O o 0 0 0 0 0 0 0 0 0 1 23.00±.250 O O O 0000000000 0 O O o 0 0 0 0 (� O O O o° o° o 0 0 0 0 o O O ° o 0 0 0 0 1 11 0 O O O ° o° 0° o° o° 0 11 0 O O 0° 0° 0° o° 0 OD O O O 0 00000000 1 DO O O 0000000000 1 �0 O O O 0000000000 O O 0 00000000 O O 0 00000000 o ° 0 2.00 2.00 - 5.00 00.75 TYP, 6.49REF. ®e CD<D o000000000 ED ED ED O o O o O o O o O o 00.38 TYP. 00.38 TYP. 1.00 SPACING REF. 00.38 TYP. 1.00 TYP. SEPT 2015 REV TRASHGUARD PLUS 23" TGRD23X24 d ACtely FOR ADDITIONAL INFORMATION PLEASE CONTACT: ACF ENVIRONMENTAL, 1-800-448-3636, www.acfenvironmental.com MOUNT HYDRANT PLUMB PROVIDE 3' MINIMUM CLEARANCE AROUND HYDRANT I /-- 4" STORZ ADAPTER 1 /2" EXPANSION JOINT MATERIAL 4" MIN-6" MAX 3' x 3' x 3.5" THICK CONCRETE PAD AROUND HYDRANT 1 CY 1-1/2" WASHED ROCK. 1' MIN ABOVE DRAIN HOLES AND AROUND HYDRANT TO BOTTOM OF DITCH LINE. COVER TOP AND SIDES WITH MIRAFI 160N OR APPROVED EQUAL. UNDISTURBED EARTHJ''/.y(/��%\\�/ 12%12%4" CONC. BLK. J/ HYDRANT CONNECTION PIPE TO BE DUCTILE IRON CLASS 52, ANY INTERMEDIATE JOINTS TO BE RESTRAINED DOUBLE SIDED BLUE RAISED PAVEMENT 18" MIN-24" MAX MARKERS ABOVE FINISHED ALIGN VALVE BOX EARS GRADE PARALLEL WITH THE FINISH GRADE WATER LINE IT SERVES I» 4„ 6" R.W. CAST IRON ADJUSTABLE _VE VALVE BOX TEE WITH :D JOINTS FLANGED FLANGED OR CONNECTION CONNECTION OM FOR HYDRANT TO VALVE VALVE INA THRUST BLOCK 10 MIL PLASTIC BETWEEN BLOCK & TEE 2" MIN CLEARANCE a BETWEEN 9. BLOCKING AND BOLTS THRUST . `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�4.s• PROPERTY LINE O R.O.W. FINISHED GRADE B CITY SUOPPLIED I r -__- BALL VALVE �� I --- ------�� I I K \ & II II LJ C \k- - �/ C I-] KK DIRECTION � _- -� OF FLOW A MATERIAL LIST: OA ALL 1" SERVICES TO BE TYPE "K" SOFT COPPER TUBING OB 1" BALL CORP. STOP WITH CC THREAD INLET AND COPPER (CTS) GRIP OUTLET (FORD OR MUELLER) OC DUAL PURPOSE UNION OD MIPT X CTS COMPRESSION FITTING BALL VALVE CURB STOP EQUAL TO FORD B84-444Q FOR 1" OWHEN REPLACING EXISTING SERVICES: 1" METER SETTER WITH ANGLE BALL METER VALVE 15" HIGH WITH DUAL E PURPOSE UNIONS ON INLET AND OUTLET, HORIZONTAL IN HORIZONTAL, OUTLET EQUAL TO FORD VB74-15W-11-44 WHEN PLACING NEW SERVICES: USE SAME AS ABOVE AND ADD A SINGLE CHECK, EQUAL TO FORD VBH74-15W-11-44 OF 1" CC TAP SERVICE SADDLE EQUAL TO ROMAC 101S OG IN UNPAVED AREAS: CARSON 1324 MSBCF WITH DUCTILE IRON COVER AND CAST IRON READER DOOR; IN PAVED AREAS: ARMOR CAST A6001946PCX12 BOX W/ A600196969 RCI LID OH FOR VACANT LOT (FUTURE USE) LOCATION MARKED WITH PAINTED 2" X 4" STAKE WITH "WATER" STENCILED ON IT lO 14 GA. VINYL COATED WIRE TRACER (TAPED TO PLASTIC PIPE EVERY 10') TO BE GROUNDED AT METER AND HOUSE OJ SCHEDULE 40 3/4" OR 1" PLUG, REMOVE WHEN CONNECTION IS MADE TO CUSTOMER LINE WITH COMPRESSION FITTING OK WATER SERVICE TO HOUSE, INSTALLED BY OWNER/CONTRACTOR (PER PLUMBING CODE) OL PROPERTY OWNER RESPONSIBLE FOR PURCHASING 3/4" OR 1" METER THROUGH THE CITY AT DEVELOPMENT SERVICES DEPARTMENT; CITY WILL SUPPLY AND INSTALL METER AFTER PURCHASE; IF USING 3/4" METER, CONTRACTOR WILL PROVIDE REDUCERS OM BACK SIDE OF METER BOX SHALL BE SET AT THE PROPERTY LINE UNLESS APPROVED BY THE CITY ENGINEER. METER BOXES SHALL NOT BE SET IN DRIVEWAY AREAS UNLESS TRAFFIC RATED BOX IS APPROVED BY CITY ENGINEER. REVISION DATE CITY OF EDMONDS WATER SERVICE 3/4"-1" AUGUST 2019 ��F7 PUBLIC WORKS INSTALLATION STANDARD DEPARTMENT DETAIL Fst. 18°� APPROVED BY: R. ENGLISH WA-1 30 Know what% below, Call bef are you dig, RAM ENGINEERING, INC. Civil Engineering / Land Planning 16531 13TH AVE W, SUITE A108 LYNNWOOD, WA 98037 PHONE: (425) 678-6960 WWW.RAMENGINEERINGINC.COM aJ z z O_ U a zcn z o � O U W 2 U O cc W O O �u Q � ti aL O O off d 38608 CZ% \� EGISTEg,�� IONe 1. PLN2020-0029 ENGINEER: LOT 1: LOT 2. 21228 21226 82ND 82ND PL PL W W (BLD2020-0687) (BLD2020- 0689) ROB L. LONG, PE DRAWN B Y.- LOT J. 21224 82ND PL W (BLD2020-0688) BR/AN CLARK LOT 4: 21222 82ND PL W (BLD2020-0690) ISSUE DATE SCALE 412112020 AS NOTED CITY OF EDMONDS JOB No: 20-003 DATE: SHEET.- DT-03 BY- CITY ENGINEERING DIVISION SHT '4 OF ,/