Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
21'0118-NYLAND-C4.1-UTL
M M N 0 N 0 0 3 J U I cD N O i7 VERTICAL DATUM BENCHMARK - SNV-7557. NAVD88. CITY OF SEATTLE BRASS CAP, STAMPED "7577". NORTHEAST CORNER OF CONC. BASE FOR STEEL TRAFFIC SIGNAL POLE IN TRAFFIC ISLAND AT SE QUADRANT OF THE INTERSECTION OF AURORA AVE NORTH & NORTH 2O5TH ST. (244TH ST. SW). ELEV= 414.60 SITE BENCHMARK: EX. SEWER MH RIM= 442.87 LJULJU00C:D0a0CD 0 0 DO ILn -- — — — — — — -- -1- D D D D I D 0 IL_ _S--" I - 5 " �- II -S D I I -- 7: Ij I I I I I � I I I i I I I II i I I II I L_ SW1/4 OF SEC. 31, T27N, R4E. , W.M., CITY OF EDMONDS, SNOHOMISH COUNTY, WA I EX. CONDOMINIUM (SUNRISE AT EDMONDS) 85XX 242ND ST SW PARCELS 006781000-10100 to 30100 EX, 10' SEWER EASEMENT AFN# 7703020257. NO EX. PIPE. ESMT. TO BE RELINQUISHED BY OVWWD. 0-07";�");)q2W4 ' 1 r1 J-Z 1— rT 4- -- - T '- ■� , ___=�IIII, _ ______ ___ ■ � !fin _ IIIIII�■1 I■ ■ ■ ■ ■I --_'_______—______ ___ C I 1 I ' C/) I I 1 I � cn 1 S W8 IXI IV- ;------- BUILDING 1 POWERSED ° W7 10 UNITS SECONDARY i PAD MOUNT i TRANSFORMER 2ND FLOOR FF= 457.00 (IF NECESSARY) 1 ST FLOOR FF= 447.00 d L------ — ' I I d ---- l I I I I drJ I I I I u) I I I1 D ---- —D --+—---------- W12 01 I _ F] F c� o — I I - i IN — P - FI L-- — — — — — -- ---j L— a u I I CP o i 1 °� I� - - BUILDING 2 9 UNITS + OFFICEI GARAGE 2ND FLOOR FF= 457.33� i 446 CD1 ST FLOOR FF= 448.00 CD II I CD I --— — — — — — — II _ D I D — D D II GARAGE I I W11 W2 II � I I I — — — — — — — — — — II I I I NEW FIRE HYDRANT PER I I I W7 SHEET 2 - WATER PLAN II I I \ 0 0 II GARAGE I I � \ it I L-- W4 OHU OHU I REMOVE EX. UTILITY oHu 0I I POLE & AERIAL I 0HU °HU I WIRES (BY PSE) �— "" l ow OHU -� off 0 01 8 � ■ N 89°07p04 ° W ° 1 25.1 4 — ° — — _ _ _ _ W1 FIRE PROTEC110N FACILITIES LEGEND SHALL NOT BE OBSTRUCTED BY LANDSCAPE PLANTING I N° _ EXISTING PROPOSED NOW OR IN FUTURE. -- PROPERTY LINE ° / I I I I I I I I F'1 I I I o I — — I ° 1 i °O 00 I �f I ° ° ° oo -- ---- J I °° o PARKING LOT LIGHT 0 I I -crzNS of n I � I �Q?�D D J J D ��------- �---- D I 446 / / o drJ �J REMOVE EX. UTILITY POLE & AERIAL WIRES (BY PSE) drJ atJ - - 0 of W7 W11 3 0 FS- 1.5" DOMESTIC METERS o PER EET 2 - WATER PLAN W3 IN 0 0 5 2 5 6 E ' NEW 12'x12' WATER ° \ - R.O.W. CENTERLINE EX. CONDOMINIUM (WINDCREST) 20.00 ESMT. TO OVWWD o 8515 244TH ST. SW EASEMENT PARCELS 00845400-100100 TO—200500 - -- 444 ■ ■ ■ WALL — — — — �0 '04" GOVERNING AGENCIES IN 89° W 60.00 100 100 GRADING CONTOUR — — 8" — — w WATER MAIN g„-- SITE, GRADING, STORMWATER ELECTRIC EX. UTILITY POLE -- — s SEWER MAIN CITY OF EDMONDS SNOHOMISH COUNTY PUD NO. 1 TO REMAIN --12"0-- o STORM DRAIN 121 5TH AVENUE NORTH CONTACT: MARY MCALLISTER S 00°52'59" W—/ 'Cr FIRE HYDRANT EDMONDS, WA 98020 PHONE: (425) 670-3216 5.00 1B WATER METER WATER, SEWER NATURAL GAS S 8 9° 0 7 0 4 E 4 0.0 0- M N GATE VALVE OLYMPIA VIEW WATER & SEWER DISTRICT PUGET SOUND ENERGY O • SEWER MANHOLE 8128 228TH STREET SW PHONE: (888) 321-7779 El STORM CB EDMONDS, WA 98026 NOTE 0❑ STORM MANHOLE CONTACT: LYNNE DANIELSON TELEPHONE THE LOCATION OF ALL EXISTING UNDERGROUND UTILITIES IS SHOWN IN AN APPROXIMATE WAY ONLY. THE CONTRACTOR PHONE: (425) 774-7769 FRONTIER SHALL OF ALL EXISTING UTILITIESETERMINE THE EXACT BEFORE COMMENCINGWORK. — — — E — E ELECTRICAL LINE CONTACT: JEREMY FALLT EXISTING GRADE INFORMATION IS APPROXIMATE. THE CONTRACTOR — — — T — T TELEPHONE LINE FIRE PHONE: (425) 263-4024 SHALL FIELD VERIFY EXISTING GRADES AND NOTIFY ENGINEER OF ANY DISCREPANCIES BEFORE COMMENCING WORK. — — — c — G GAS LINE SOUTH SNOHOMISH COUNTY FIRE & RESCUE CONTRACTOR AGREES TO BE FULLY RESPONSIBLE FOR ANY AND © POWER VAULT CONTACT: KEVIN ZWEBER CABLE ALL DAMAGES WHICH MIGHT BE OCCASIONED BY HIS FAILURE TO CONFIRM EXISTING UTILITY AND GRADE INFORMATION. PHONE: (425) 771-0213 COMCAST CALL AT LEAST 2 WORKING � + UTILITY POLE CONTACT: MIKE FONTENOT DAYS BEFORE YOU DIG STREET LIGHT PHONE: (425) 263-5482 CALL'811' PROPOSE[ POWER PRIMARY NEW 1" IRRIGATION METER PER SHEET 2 — WATER PLAN W5 T— C� 4�- � I 0 I o� 00 o� 00 o� 7r I �Iac 0 d- `r c0 0 TERR%AFORMA WPF o o s DESIGN GROUP, INC. .,� 0 OD CIVIL ENGINEERING & LANDSCAPE ARCHITECTURE OIII O cc c 5027 51ST Avenue SW Seattle WA 98136 0 C4 5 phone 206.923.0590 website terraformadesigngroup.com �a J C a8 12 C~ PROJECT TEAM V 1:■� w CIVIL ENGINEER OWNER/DEVELOPER H TERRAFORMA DESIGN GROUP, INC. NYLAND, LLC 5027 51ST AVENUE SW CONTACT: STEVE BARNES 2 O 00 SEATTLE, WA 98136 PHONE: (206) 550-9296 U OD CONTACT: PEDRO DEGUZMAN, PE W CO 0) PHONE: (206) 923-0590 GEOTECHNICAL ENGINEER Q m o EMAIL: pedro®terraformadesigngroup.com ASSOCIATED EARTH SCIENCES, INC. o� CONTACT: KURT D. MERRIMAN, PE Co ARCHITECT PHONE: (425) 827-7701 , W CORNERSTONE ARCHITECTURAL GROUP REPORT DATED: FEB. 11, 2016 CONTACT: STEVE BARNES W m PHONE: (206) 682-5000 Z E � mY OPRIVATE WATER FACILITIES NOTES © CORNERSTONE ARCHITECTURAL GROUP DENNY'S TA EDMONDS LLC 8431 244TH ST. SW ARCEL 00463303200102 EX. 10' SEWER EASEMENT AFN# 1988205. NO EX. PIPE. ESMT. TO BE RELINQUISHED \BY OVWWD. FIRE PROTECTION FACILITIES SHALL NOT BE OBSTRUCTED BY LANDSCAPE PLANTING NOW OR IN FUTURE. MAINTAIN 3-FT CLEARANCE AROUND FDC. ** FOR PUBLIC WATER FACILITIES (OWNED / OPERATED o N. w� y (2& BY OLYMPIC VIEW WATER & WASTEWATER DISTRICT ���� 'tico REFER TO SHEET 2. Z W1 1.5" DOMESTIC DCVA (BLDG #1) PER OVWWD STD. DTL. W-11 31111 646 F �F0 STERN° W2 133' — 2" DOMESTIC POLY, SIDR7 TO BLDG #1 SS�O 'AL ECG W3 1.5" DOMESTIC DCVA (BLDG #2) PER OVWWD STD. DTL. W-11 1/18/21 W4 114' - 2" DOMESTIC POLY, SIDR7 TO BLDG #2 W5 1" IRRIGATION DCVA PER OVWWD STD. DTL. W-11 > W6 STA 22+54.00: > 2" FIRE SERVICE METER FOR BLDG #1 PER WATER SHT. #2. 2" DCVA PER STD. DTL. W-11 W7 186' — 2" FIRE SERVICE (POLY, SIDR7) TO BLDG #1 PIPE SHALL CROSS UNDER DOMESTIC SERVICES. 14 GA LOCATOR WIRE ALONG FIRE LINE. W8 INTERIOR FIRE SPRINKLER RISER BY SEPARATE FIRE PERMIT. DESIGNED BY MOORE FIRE PROTECTION. SIZING OF FIRE SERVICE BASED ON MOOR FIRE PROTECTION PLANS. W9 FIRE DEPT. CONNECTION FOR BLDG #2: EQUIP WITH 4" STORZ ADAPTOR AND A 30—DEG DOWNTURN S T 1 C 1 W10 STA 22+52.00: 2" FIRE SERVICE METER FOR BLDG #2 PER WATER SHT. #2 2" DCVA PER STD. DTL. W-11 W11 164' — 2" FIRE SERVICE (POLY, SIDR7) TO BLDG #2 PIPE SHALL CROSS UNDER DOMESTIC SERVICES. 14 GA LOCATOR WIRE ALONG FIRE LINE. W12 INTERIOR FIRE SPRINKLER RISER BY SEPARATE FIRE PERMIT. DESIGNED BY MOORE FIRE PROTECTION. SIZING OF FIRE SERVICE BASED ON MOOR FIRE PROTECTION PLANS. W13 FIRE DEPT. CONNECTION FOR BLDG #2: EQUIP WITH 4" STORZ ADAPTOR AND A 30—DEG DOWNTURN SEE DTL. 1 /C4.1. DEVLOPER SHALL OBTAIN FIRE MARSHAL APPROVAL 4" Schedule 40 4" Storz FDC with Sign NO-- 4" x 2" Threaded Reducing 90° Elbow Z with 30' downturn O ° r 2" Schedule 40 I w V) FINISH GRADE •r 3 mil Polywrap 1 > 7 Z 1 1 w FDC TO BE PAINTED RED AND LABELED WITH BUILDING O 7 L ADDRESS. ADDITIONAL SIGNAGE REO'D PER NFPA 13. 2" HOLY 0 J 2" x 1h" x 2" Galy. Reducing Tee s U � 0'h" Automatic Drain Valve into Gravel- 2"Ch kV 2" Male Adapter I \ ec a ve U=X. SEWER EASEMENT C/)gFN# 1988205 1 FIRE DEPT. CONNECTION EX, UNDERGROUND C4.1 SCALE: N.T.S. z W ACCESSS & POWER, TELE & O LU TILITY ESMT. = I CATV BY TEKIN I DEVELOPMENT PPPRAIT• Pi mnl7umnann W _ --- 0 6 10 w 1 inch = 10 ft. APPROVED FOR CONSTRUCTION CITY OF EDMONDS DATE: BY. CITY ENGINEERING DIVISION co N O z w � Uo �O Q � C:0 co w Qz 3: L OVJ Z Q N 0 z LO 00 N •• 00 O w ~ LLJ o 0Y C401