16mm-SG-ASTM-D1929-1ffmsl
i&�E�
CLIENT: POLYGAL, INC.
P.O. Box 410592
Charlotte, NC 28273
Ward Ogle
[TeLstReport No: 97808-8 Date: May 9, 2007
SAMPLE ID: The Client submitted and identified the following test material as Polygal 16mm SG
Multi -wall Polycarbonate Panel.
DATE OF RECEIPT: Entered into SGS USTC sample tracking system on April 20, 2007.
TESTING PERIOD: May 8, 2007.
AUTHORIZATION: Testing authorized by Ward Ogle.
TEST REQUESTED: "Determining Ignition Temperature of Plastics" per ASTM D1929-01.
Self ignition temperature only.
TEST RESULTS:
REQUIREMENT:
Self
Ignition Temperature
520-C (968°F)
Number of
Specimens Tested
4
Self ignition temperature greater than 650°F per IBC Section 2606, Para. 2606.4
CONCLUSION: The submitted sample meets the requirement.
Tested by Signed for and on behalf of
SGS U.S. Testing Company Inc.
Brian Ortega Greg Banasky
Test Technician Page 1 of 1 Supervisor Fire Technology
This report is issued by SGS U.S. Testing Company Inc. under its General Conditions for Testing Services (copy available on request) SGS U.S.
Testing's responsibility under this report is limited to proven negligence and will in no case be more than the amount of the testing fees. Except by
special arrangement, samples are not retained by SGS U.S. Testing for more than 30 days. The results shown on this test report refer only to the
sample(sj tested unless otherwise stated, under the conditions agreed upon. Anyone relying on this report should understand all of the details of the
engagement. Neither the name, seals, marks nor insignia of SGS U-S. Testing may be used in any advertising er promotional materials without the prior
written approval of SGS U.S. Testing. The test report cannot be reproduced, except in full, without prior written permission of SGS U.S. Testing
Company Inc.
SGS U.S. Testing Company Inc. I Consumer Testing Services 8386 White Oak Avenue Rancho Cucamonga, CA 91730
Member of SGS Group (Societe Generale de Surveillance)