Engineering Permit FormSEWER NEW
RESIDENTIAL PERMIT
City
of • • •
Edmonds98020 ENG2022-0278
www.cityofedmonds.gov
Description: NEW 4" SIDE SEWER FOR SFR CONNECTED TO SP STUB
ISSUED: 08/02/2022
Address: 1400 9TH AVE N EDMONDS WA 98020
EXPIRES: 07/28/2023
Permit Type: SEWER NEW RESIDENTIAL Permit Subtype: Parcel Number: 00608300000201
iiiii
10101 '
NAME TYPE NAME
ADDRESS PHONE
APPLICANT
LEE MICHAELIS
6100 219TH ST SW SUITE 480, MOUNTLAKE TERRACE WA
(425)830-1046
98043
CONTACT
PUGET SOUND PLANNING, LLC
6100 219TH ST SW SUITE 480, MOUNTLAKE TERRACE WA
(425)830-1046
98043
CONTRACTOR
LEIF HELLEREN CONSTRUCTION INC
PO BOX 1764, EDM0NDS WA 98020
(206)533-8200
OWNER DESTA & SOLOMON GENET
20204 37TH AVE W, LYNNWOOD WA 98036
GETACHEW
FEE INFORMAJ11111MM
DESCRIPTION
AMOUNT PAID
CITY TECHNOLOGY FEE CHARGED PER PERMIT
$40.00 $40.00
SEWER GENERAL FACILITY CHARGE - NEW SFR
$4,417.00 $4,417.00
SIDE SEWER PERMIT - NEW RESIDENTIAL
$110.00 $110.00
THIS DOCUMENT IS NOT VALID UNTIL FEES ARE PAID AND THE CITY ENGINEER OR HIS/HER DEPUTY HAS SIGNED BELOW
Ul119q
Printed: Tuesday, August 02, 2022 10:11:35 AM 1 of 3
RELEASED BY
Printed: Tuesday, August 02, 2022 10:11:35 AM 2 of 3
I j SEWIMEW
RESIDENTIAL PERMIT
U-
City of • • •
t
Edmonds•:• •ENG2022-0278
. -. ov/425.771.0220
T,%qlz
CONDITIONS
CONDITION TYPE
It is the owner's responsibility to repair/replace all damage of utilities or frontage improvements in
DAMAGE TO FRONTAGE
City right of Ways or Easements to City Standards caused by or occurring during the permitted
IMPROVEMENTS
project.
MAINTAIN EROSION AND SEDIMENTATION CONTROL PER CITY AND SWMMW STANDARD
ESC REQUIREMENTS
REQUIREMENTS.
INSP PRIOR TO BACKFILL
Call for all required inspections. All work shall be inspected prior to backfill.
SEWER AND WATER
MAINTAIN 10 FEET OF SEPARATION BETWEEN THE SANITARY SIDE SEWER AND THE WATER SERVICE
SEPARATION
LINE.
Owner/Contractor to provide Side Sewer asbuilt at final inspection. See City Handout E71 for
SEWER ASBUILT
requirements.
PLEASE REFER TO STANDARD DETAILS SS-200, SS-201 AND, SS-202. STANDARD DETAILS CAN BE
FOUND ON THE CITY OF EDMONDS WEBSITE. SDR35 WITH GASKETED FITTINGS IS REQUIRED FOR ALL
SEWER REPAIRS. FOR ANY REPAIRS WHERE THERE IS MORE THAN ONE STICK OF PIPE, A PRESSURE
SEWER REQUIREMENTS
TEST IS REQUIRED. WHERE LINING OR PIPE BURSTING WATER AND TV TEST IS REQUIRED. IF THE 4-6
TRANSITION IS ENCOUNTERED, A 6" CLEANOUT IS REQUIRED AT THE PROPERTY LINE. THE 6"
CLEANOUT SHALL HAVE A 12" CAST IRON LAMPHOLE COVER WITH 1/2 HEX BOLTS, GRIPPER TWIST
PLUG, AND A 24" CONCRETE COLLAR. AN AS BUILT IS REQUIRED PRIOR TO FINAL OF THE PERMIT.
Sound or noise originating from temporary construction sites as a result of construction activity are
exempt from the noise limits of ECC Chapter 5.30 only during the hours of 7:OOam to 6:OOpm on
SOUND AND NOISE
weekdays and 10:OOam and 6:OOpm on Saturdays, excluding Sundays and Federal Holidays. At all
other times the noise originating from construction sites and activities must comply with the noise
limits of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120.
All utilities shall be located prior to any excavation. New locates shall be called for if at time of
UTILITY LOCATES
excavation, original locates are no longer identifiable.
INSPECTION TYPE
DATE
7RESULjTjrNOTES
OR
COMPLETE
E-2 SIDE SEWER
X-2 ENGINEERING FINAL"
E-2 SEWER PRESSURE
Printed: Tuesday, August 02, 2022 10:11:35 AM 3 of 3