Loading...
ENG2022-0278_Issued_Permit_8-2-2022_Engineering_Permit_Form(2)SEWER NEW RESIDENTIAL PERMIT City of • • • Edmonds98020 ENG2022-0278 www.cityofedmonds.gov Description: NEW 4" SIDE SEWER FOR SFR CONNECTED TO SP STUB ISSUED: 08/02/2022 Address: 1400 9TH AVE N EDMONDS WA 98020 EXPIRES: 07/28/2023 Permit Type: SEWER NEW RESIDENTIAL Permit Subtype: Parcel Number: 00608300000201 iiiii 10101 ' NAME TYPE NAME ADDRESS PHONE APPLICANT LEE MICHAELIS 6100 219TH ST SW SUITE 480, MOUNTLAKE TERRACE WA (425)830-1046 98043 CONTACT PUGET SOUND PLANNING, LLC 6100 219TH ST SW SUITE 480, MOUNTLAKE TERRACE WA (425)830-1046 98043 CONTRACTOR LEIF HELLEREN CONSTRUCTION INC PO BOX 1764, EDM0NDS WA 98020 (206)533-8200 OWNER DESTA & SOLOMON GENET 20204 37TH AVE W, LYNNWOOD WA 98036 GETACHEW FEE INFORMAJ11111MM DESCRIPTION AMOUNT PAID CITY TECHNOLOGY FEE CHARGED PER PERMIT $40.00 $40.00 SEWER GENERAL FACILITY CHARGE - NEW SFR $4,417.00 $4,417.00 SIDE SEWER PERMIT - NEW RESIDENTIAL $110.00 $110.00 THIS DOCUMENT IS NOT VALID UNTIL FEES ARE PAID AND THE CITY ENGINEER OR HIS/HER DEPUTY HAS SIGNED BELOW �evk,,St° Nt°LSOV1, (for JW) 8/2/2022 IBY11ra Printed: Tuesday, August 02, 2022 10:11:38 AM 1 of 3 RELEASED BY Printed: Tuesday, August 02, 2022 10:11:38 AM 2 of 3 I j SEWIMEW RESIDENTIAL PERMIT U- City of • • • t Edmonds•:• •ENG2022-0278 . -. ov/425.771.0220 T,%qlz CONDITIONS CONDITION TYPE It is the owner's responsibility to repair/replace all damage of utilities or frontage improvements in DAMAGE TO FRONTAGE City right of Ways or Easements to City Standards caused by or occurring during the permitted IMPROVEMENTS project. MAINTAIN EROSION AND SEDIMENTATION CONTROL PER CITY AND SWMMW STANDARD ESC REQUIREMENTS REQUIREMENTS. INSP PRIOR TO BACKFILL Call for all required inspections. All work shall be inspected prior to backfill. SEWER AND WATER MAINTAIN 10 FEET OF SEPARATION BETWEEN THE SANITARY SIDE SEWER AND THE WATER SERVICE SEPARATION LINE. Owner/Contractor to provide Side Sewer asbuilt at final inspection. See City Handout E71 for SEWER ASBUILT requirements. PLEASE REFER TO STANDARD DETAILS SS-200, SS-201 AND, SS-202. STANDARD DETAILS CAN BE FOUND ON THE CITY OF EDMONDS WEBSITE. SDR35 WITH GASKETED FITTINGS IS REQUIRED FOR ALL SEWER REPAIRS. FOR ANY REPAIRS WHERE THERE IS MORE THAN ONE STICK OF PIPE, A PRESSURE SEWER REQUIREMENTS TEST IS REQUIRED. WHERE LINING OR PIPE BURSTING WATER AND TV TEST IS REQUIRED. IF THE 4-6 TRANSITION IS ENCOUNTERED, A 6" CLEANOUT IS REQUIRED AT THE PROPERTY LINE. THE 6" CLEANOUT SHALL HAVE A 12" CAST IRON LAMPHOLE COVER WITH 1/2 HEX BOLTS, GRIPPER TWIST PLUG, AND A 24" CONCRETE COLLAR. AN AS BUILT IS REQUIRED PRIOR TO FINAL OF THE PERMIT. Sound or noise originating from temporary construction sites as a result of construction activity are exempt from the noise limits of ECC Chapter 5.30 only during the hours of 7:OOam to 6:OOpm on SOUND AND NOISE weekdays and 10:OOam and 6:OOpm on Saturdays, excluding Sundays and Federal Holidays. At all other times the noise originating from construction sites and activities must comply with the noise limits of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120. All utilities shall be located prior to any excavation. New locates shall be called for if at time of UTILITY LOCATES excavation, original locates are no longer identifiable. INSPECTION TYPE DATE 7RESULjTjrNOTES OR COMPLETE E-2 SIDE SEWER X-2 ENGINEERING FINAL" E-2 SEWER PRESSURE Printed: Tuesday, August 02, 2022 10:11:38 AM 3 of 3