Loading...
REVIEW FIR FIR2021-0118+Fire_Sprinkler_Equipment_Specification_Sheets+10.25.2021_12.25.41_PM+2481147ES-A-2000B Series 2000B Double Check Valve Assemblies Sizes: 1/2" — 2" (15 — 50mm) Features • Ease of maintenance with only one cover • Top entry • Replaceable seats and seat discs • Modular construction • Compact design • 1/2" — 2" (15 — 50mm) Cast bronze body construction • Top mounted ball valve test cocks • Low pressure drop • No special tools required • 1/2" — 1 " (15 — 25 mm) have tee handles Available Models Suffix: B - Quarter turn ball valves LBV - less ball valves SH - stainless steel ball valve handles HC - 2'/2" inlet/outlet fire hydrant fitting (2" valve) Pressure — Temperature Temperature Range: 33°F — 140°F (0.5°C — 60°C) Maximum Working Pressure: 175psi (12.1 bar) Standards AWWA Std. C510, IAPMO PS31 Job Name Job Location Engineer Approval A A M E S FIRE & WATERWORKS C.. I 2" 2000B HC (50mm) % so, &W W 2000B (20mm) Series 2000B Double Check Valve Assemblies shall be installed at referenced cross - connections to prevent the backflow of polluted water into the potable water supply. Only those cross -connections identified by local inspection authorities as non -health hazard shall be allowed the use of an approved double check valve assembly. Check with local authority having jurisdiction regarding vertical orientation, frequency of testing or other installation requirements. These valves meet the requirements of ASSE Std. 1015 and AWWA Std. C510 and are approved by the Foundation for Cross -Connection Control and Hydraulic Research at the University of Southern California. Specifications A Double Check Valve Assembly shall be installed at each noted location. The assembly shall consist of two positive seating check modules with captured springs and rubber seat discs. The check module seats and seat discs shall be replaceable. Service of all internal components shall be through a single access cover secured with stainless steel bolts. The assembly shall also include two resilient seated isolation valves and four top mounted, resilient seated test cocks. The assembly shall meet the requirements of ASSE Std. 1015 and AWWA Std. C510. Approved by the Foundation for Cross -Connection Control and Hydraulic Research at the University of Southern California. Assembly shall be an Ames Company Series 2000B. Approvals Assif", H55E ��® N C Q. US c us 1015 B64.5 (LBV Models Only) Approved by the Foundation for Cross -Connection Control and Hydraulic Research at the University of Southern California. LBV models not listed. Horizontal and vertical "flow up" approval on all sizes. Contractor Approval Contractor's P.O. No. Representative Ames product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please contact Ames Technical Service. Ames reserves the right to change or modify product design, construction, specifications, or materials without prior notice and without incurring any obligation to make such changes and modifications on Ames products previously or subsequently sold. www.amesfirewater.com Dimensions - Weights Suffix HC - Fire Hydrant Fittings dimension "A" = 23'/2" (594mm) (ON) DIMENSIONSSIZE in. mm A in. mm in. B mm C in. mm F in. mm G in. mm H in. mm in. I mm lbs. kgs. '/2 15 10 254 4% 117 2'/16 62 5 127 3% 85 26/16 59 2'/16 52 4.5 2 3/4 20 11 % 282 4 102 3'/s 79 63/ 6 157 V16 87 2% 54 16/ 6 33 5 2.3 1 25 13'/4 337 1 51/8 130 1 4 102 1 7'/2 191 1 3% 85 11'/6 43 111/6 43 1 12 5.4 1'/4 32 16% 416 5 127 36/6 84 91h 241 5 127 3 76 2 50 15 6.8 11/2 40 163/4 425 4'/8 124 31h 89 93/4 248 51Y16 148 3'/s 79 2"/6 68 15.86 7.2 2 50 19'/2 495 6'/4 159 4 102 13% 340 6'/8 156 37/6 87 2"/16 68 25.75 11.7 Strainer sold separately Capacities As compiled from documented Foundation for Cross -Connection Control and Hydraulic Research at the University of Southern California lab tests. ATypical maximum system flow rate (7.5 feet/sec., 2.3 meters/sec.) kPa psi 112" (15mm) y 83 12 0 69 10 m 55 8 41 6 N 28 4 aNi 14 2 a 0 0 0 2 4 6 8 10 12 gpm AP 0 7.6 15.2 22.8 30.4 38 45.6 Ipm 5 7.5 10 fps 1.5 2.3 3.0 mps Flow Rate ��■ ����■ IIIIIIIIIIIII■IIIIIIIIIIIII■■ IIIII■IIIIIIIIIIIII■IIIIIIIIIIIII■IIIIIIIIIIIII■■ IIIIIIIIIIIII■IIIIIIIIIIIII■■ IIIII■IIIIIIIIIIIII■IIIIIIIIIIIII■IIIIIIIIIIIII■■ 69 1 ��■ ����■ IIIIIIIIIIIII■IIIIIIIIIIIII■■ IIIII■IIIIIIIIIIIII■IIIIIIIIIIIII■IIIIIIIIII�� 41 ��■ ����■ 14 ;ice■ ����■ kPa psi 11/4 ° (32MM) 96 14 A 83 12 N o 69 10 y 55 8 7 41 6 d 28 4 14 2 a- 0 0 AP 0 10 20 30 40 50 60 70 80 90 100 110 120 gpm 0 38 76 114 152 190 228 266 304 342 380 418 456 Ipm 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps Flow Rate kPa psi 83 12 H 69 10 0 55 8 0 41 6 3 28 4 d14 2 n n LL AP 0 5 10 15 20 25 30 35 40 45 50 gpm 0 19 38 57 76 95 114 133 152 171 190 Ipm 7.5 15 fps 2.3 4.6 mps Flow Rate 0 kPa psi 11I (25mm) o y 110 16 A J 0 83 12 i m 69 10 W 7 55 8 H 41 6 28 4 I1 I1 14 2 0 5 10 15 20 25 30 35 40 45 50 55 60 gpm AP 0 19 38 57 76 95 114 133 152 171 190 209 228 Ipm 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps Flow Rate .AA A M E S FIRE & WATERWORKS A Watts Water Technologies Company ES-A-200013 1322 pp0 10 20 30 40 50 60 70 80 90 100 110 120 gpm 0 38 76 114 152 190 228 266 304 342 380 418 456 Ipm 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps Flow Rate kPa psi 2" (50mm) 83 12 69 10 55 8 41 6 28 4 14 2 0 0 0 25 50 75 100 125 150 175 200 gpm OP 0 95 190 285 380 475 570 665 760 Ipm 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps Flow Rate www.amesfirewater.com aOW Loi,I,C o R II 11. USA: Backflow- Tel: (916) 928-0123 • Fax: (916) 928-9333 Control Valves- Tel: (713) 943-0688 • Fax: (713) 944-9445 Canada: Tel: (905) 332-4090 • Fax: (905) 332-7068 0 2013 Ames Fire & Waterworks Relmlabie Reliable Riser - Residential 1" (25mm), 1/" (40mm), and 2" (50mm) sizes. For use in NFPA 13D and 13R Residential Systems Features: 1. Stainless Steel body construction. 2. All brass trim. 3. Factory assembled. 4. Factory pressure tested at 200 psi. (13.8 bar). 5. Choice of trim: • Basic Trim (Fig. 1). • Basic Trim with Pressure Relief Kit (Fig. 2). • Basic Trim with Test and Drain Valve (Fig. 3). • Basic Trim with Test and Drain Valve and Pressure Relief Kit (Fig. 4). 6. Choice of mounting options: • Supply / System lines support. • Support Bracket (to stud) (Figs. 5 & 6). • Recessed or Flush mount (to wood panel) (Fig. 7). 7. NPT (female x female) or tapered metric (female x female) connections. 8. Slim design allows for easy installation within 2" x 4" on 16" centers wood frame construction. 9. Dedicated UL Listed and ULC Listed Water Flow Detector assures optimum sensitivity. Water Flow Detector is factory installed with a metallic, weatherproof cover. Triggeringflow rate is 4(15) GPM(LPM) to 10(38)GPM(LPM). Approvals & Listings 1. Listed by Underwriters Laboratories Inc. and ULC Listed. 2. NYC MEA 258-93-E Bulletin 425 Rev. B Reliable Riser - Residential Fig. 1 Base Trim Fig. 2 Base Trim with Pressure Relief Kit Fig. 3 Base Trim with Test and Drain Valve Fig. 4 Base Trim with Test and Drain Valve & Pressure Relief Kit W c N CP M 9-4 The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Optional Trims - Technical Data: Description Basic Trim Basic Trim with Pressure Basic Trim with Test and Basic Trim with Test and Drain Relief Kit Drain Valve Valve & Pressure Relief Kit Take Out Dimensions Weight* Dimensions Wei ht" Dimensions Weight* Dimensions Weight* Dimension Manifold Size: Lbs Lbs Lbs Lbs inch inch inch inch inch inch (kgs) inch inch (kgs) inch mm(mm)(kgs) mm(mm)(kgs) mm mm mm mm mm 1" 11 8% 7.3 13J, 11 8.7 11 14J, 9.0 15 14J, 10.6 8 J; 25mm 279 222 3.32 343 279 3.95 279 362 4.09 381 362 4.82 210 1y" 11 9X 8.3 13y 11y 10.5 11 14% 9.7 15 14% 11.2 8 Y, 40mm (279) (235) (3.77) (343) (292) (4.77) (279) (375) (4.41) (381) (375) (5.09) (210) 2" 11 9% 8.8 13'/ 12 11.1 11 15y 10.5 15 15J; 12.2 8 50mm 279 248 4.00 343 305 5.05 279 387 4.77 381 387 5.55 210 * Support Bracket Kit (optional) - 1 lb (0.45 kg) All Reliable Risers have a 1" NPT drain port. Basic Trim With Pressure Relief Flit Basic Trim with Test and Drain Pressure Relief Flit Water Water B Press. Relief Pressure III B Gau e Press. Relief PressuGaugers it (Opt.) g Kit (Opt.) Manifold System Manifold System Body Support \ Body ` \ Support Bracket Bracket \�I C (Take -Out) A C A (Ta k e- Out) Supply Supply Drain Drain Test and Drain Drain Valve Valve Water Flow Detector Water Flow Detector (Contact Ratings: 10A [,1a 125250 VAC 2.5A [�1a 24VDC) (Contact Ratings: 10A @ 125250 VAC 2.5A @ 24VDC) Product Description: The Reliable -Risers come factory assembled with all of the necessary accessories for a cost effective, yet complete riser solution. Reliable -Rises are [UL Listed][ULC Listed] [NYC Approved MEA 258-93-E] for horizontal or vertical installations as a one-piece, factory assembled unit for use in NFPA 13D and 13R residential sys- tems. The riser manifold assembly shall consist of a (choose one): • 1" (25 mm) cast, non -welded stainless steel body with 1" female NPT or IS07-Rc1-11 threaded end connections. Fig. 5 • 1-Y" (40 mm) cast, non -welded stainless steel body with 1-/" female NPT or IS07-Rc1.5-11 threaded end connections. • 2" (50 mm) cast, non -welded, stainless steel body with 2" female NPT or IS07-Rc2-11 threaded end connections. All of these manifold sizes have cast -on lettering that clearly identifies the manifold's pipe size, flow direction, UL Listing/ ULC Listing, and the test and drain outlet. A built-in drain port is included to per- mit hydrostatic testing without draining the system. The assembly has a working pressure rating of 175 2. psi (12.1 bar). Cast -in mounting holes are provided for recessed or flush mounting to a wall. For stud mounting, a support bracket is available that is spe- cifically designed for the cast mounting holes. All of the trim variations include brass compo- nents, a cULus Listed 300 psi water pressure gauge, and a 250 psi UL Listed/ ULC Listed Waterflow Detector. This Waterflow Detector comes factory installed with a weatherproof (outside) cover. Trim Descriptions • Basic Trim Residential riser manifold assembly trim shall include a cULus Listed pressure gauge, a drain valve, and dedicated waterflow detector containing two sets of SPDT (Form C) contacts, having an electrical rating of 10A @ 125/250 VAC/2.5 A @ 24 VDC. Triggering flow rate is 4(15) GPM(LPM) to 10(38) GPM(LPM). • Basic Trim with Pressure Relief Kit Residential riser manifold assembly trim shall include a cULus Listed pressure gauge, a drain valve, and dedicated waterflow detector containing two sets of SPDT (Form C) contacts, having an electrical rating of 10A @ 125/250 VAC/2.5 A @ 24 VDC. Triggering flow rate is 4(15) GPM(LPM) to 10(38) GPM(LPM). Pressure relief valve kit shall be provided to maintain system pressures below 175 psi (12.1 bar). • Basic Trim with Test and Drain Valve Residential riser manifold assembly trim shall include a cULus Listed pressure gauge, a Test and Drain valve, and a dedicated waterflow detector containing two sets of SPDT (Form C) contacts, having an electrical rating of 10A @ 125/250 VAC/2.5 A @ 24 VDC. Triggering flow rate is 4(15) GPM(LPM) to 10(38) GPM(LPM). The test orifice size for the Test and Drain assembly shall be** **(Choose one) • 3/8" (10 mm) • 7/16" (11 mm) • 1/2" (15 mm) Basic Trim with Test and Drain Valve & Pressure Relief Kit Residential riser manifold assembly trim shall include a cULus Listed pressure gauge, a Test and Drain valve, and a dedicated waterflow detector containing two sets of SPDT (Form C) contacts, having an electrical rating of 10A @ 125/250 VAC/2.5 A @ 24 VDC. Triggering flow rate is 4(15) GPM(LPM) to 10(38) GPM(LPM). Pressure Relief Kit shall be provided to maintain system pressures below 175 psi (12,1 bar). Installation: 1. Install the manifold with the flow arrow pointing towards SYSTEM side using threaded connec- tions. 2. Connect a 1" NPT drain line. Ensure the drain Ball Valve is in the CLOSED position. 3. Place the sprinkler system in service. Caution: Automatic sprinkler systems having non -fire protection connection (permitting continual water flow) require dielectric fittings, according to NFPA 13 sect. 4-6, when dissimilar metal piping materials are joined. Note: 2 112" MINIMUM CAP FOR WATER FLOW INDICATOR COVER REMOVAL(TYPICAL ALL MANIFOLDS) STUD SUPPORT BRACKET MOUNT BRACKET FLUSH WITH FACE OF STUD Fig.6 WOOD PANEL PLASTIC SPACERS STUD T__-7 --- —C RECESSED OR FLUSH MOUNTED 3. Fig.7 Ordering Information: Residential Riser Part Number Code Key IN 1M 1.5N 1.5M 2N 2M 1 N =1" (25mm) NPT Threaded Ends Assembly 1 M =1" (25mm) Metric Threaded Ends Assembly 1.5N = 1-1/2' (40mm) NPT Threaded Ends Assembly 1.5M = 1-1/2' (40mm) Metric Threaded Ends Assembly 2N = 2" (50mm) NPT Threaded Ends Assembly 2M = 2" (50mm) Metric Threaded Ends Assembly B T38 T716 T12 B = Basic Trim Assembly T12 = Basic Trim Assembly with 1/2' (15mm) Orif. Test and Drain Valve 0 1 2 3 0 = Assembly without Pressure Relief Kit Water Detector - UL & FM Approved 1 = Assembly with Pressure Relief Kit Water Detector - UL & FM Approved 2 = Assembly without Pressure Relief Kit Water Flow Detector - ULC Approved 3 = Assembly with Pressure Relief Kit Water Flow Detector - ULC Approved Example #1: 1.5N — B —1 (1-112" (40mm) Residential Riser Assembly with NPT Female Inlet and Outlet Threads, Basic Trim with installed Pressure Relief Kit). Example #2: 2M — T12 — 0 (2" (50mm) Residential Riser Assembly with Metric Female Inlet and Outlet Threads, Basic Trim with Test and Drain Valve having a 112" Diameter Test Orifice.) Also, If Required: Description Part Number Pressure Relief Kit For Basic Trim 98020076 Pressure Relief Kit For Basic Trim with Test and Drain Valve 6501203551 Support Bracket Kit 6899190001 Waterflow Detector RFDTH 96556910 Waterflow Detector ULC RFDTHA 96556914 Paddle Tree - Waterflow Detector 96556911 The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 80 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by The Reliable Automatic Sprinkler Co., Inc. ® Recycled iablim (800) -1588 Sales Offices Pap er 84 Rel(800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices Revision lines indicate updated or new data www.reliablesprinkler.com Internet Address E.G. Printed in USA 08/09 P/N9999970348 Bulletin 006 December 2018 Reliable Model RFC Series Residential Sprinklers Flat Cover Plate, Concealed Pendent Sprinkler cULus Listed Features cULus Listed as Residential Sprinklers Push -On cover plate installation Low water flow requirements Product Description Model RFC Series residential sprinklers are flat cover plate, concealed pendent sprinklers intended for installation in accordance with NFPA 13, NFPA 13R, or NFPA 13D. The sprinklers are cULus Listed as Residential Sprinklers in ac- cordance with UL 1626. In addition, Model RFCLL Series sprinklers are cULus Certified for Health Effects to NSF/ANSI standard 61 Annex G (LL). Model RFC30 and RFC43 sprinklers have a 1650F (74°C) temperature rated fusible -link operating element. Model RFC49, Model RFC58, and RFC76 sprinklers are offered with either a 1650F (74°C) or 212°F (100°C) temperature rated fusible -link operating element. Sprinklers with a 1650F (74°C) temperature rating are ordinary temperature classification and are listed for use with a 1350F (57°C) temperature rated cover plate. Sprinklers with a 212OF (100°C) temperature rat- ing are intermediate temperature classification and are listed for use with a 1650F (74°C) temperature rated cover plate. Model RFC Series sprinklers are installed with a Model RFC cover plate. Model RFC cover plates may be installed by ei- ther pushing or threading the cover plate into the sprinkler cup. Model RFC30, RFC30LL, RFC43, RFC43LL, RFC49 and RFC49LL sprinklers allow 1/2" (13 mm) of cover plate adjust- ment. Model RFC58 and RFC76 sprinklers allow 3/4" (19 mm) of cover plate adjustment. Model RFC cover plates are avail- able in a variety of finishes as listed in Table H. Model RFC30 & RFC30LL Model RFC49 & RFC49LL Model RFC76 Model RFC43 & RFC43LL Model RFC58 Model RFC Cover Plate Sprinkler Model Nominal K-Factor gpm/psi (1/min/bary/2 ) Max. Coverage Area ft x ft (m x m) Listings & Approvals Sprinkler Identification Number (SIN) RFC30 3.0(43) 14 x 14 (4.3 x 4.3) cULus RA0611 RFC30LL 3.0(43) 14 x 14 (4.3 x 4.3) cULus, LL RA3211 RFC43 4.3(62) 20 x 20 (6.1 x 6.1) cULus RA0612 RFC43LL 4.3(62) 20 x 20 (6.1 x 6.1) cULus, LL RA3212 RFC49 4.9(71) 20 x 20 (6.1 x 6.1) cULus RA0616 RFC49LL 4.9(71) 20 x 20 (6.1 x 6.1) cULus, LL RA3216 RFC58 5.8(84) 20 x 20 (6.1 x 6.1) cULus RA0613 RFC76 7.6(109) 20 x 20 (6.1 x 6.1) cULus RA0618 cULus: cULus Listed to UL1626, Residential Sprinklers for Fire Protection Service. LL: cULus Certified for Health Effects to NSF/ANSI Standard 61 Annex G (Less than 0.25% Lead content). www.reliablesprinkler.com Technical Specifications Style: Flat Concealed Pendent Threads: 1/2" NPT or ISO 7-1 R1/2 Nominal K-Factor: 3.0 (43 metric) Max. Working Pressure: 175 psi (12 bar) Min. Spacing: 8 ft. (2.4 m) Material Specifications Thermal Sensor: Nickel Alloy Solder Link Sprinkler Body: Brass Alloy Levers: Bronze Alloy Yoke: Brass Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Towers: Copper Alloy Pins: Stainless Steel Deflector: Bronze Alloy Cup: Steel Cover Plate Finishes (See Table H) Sensitivity Fast -response Temperature Rating 165°F (74°C) sprinkler 135°F (57°C) cover plate Cover Plate Model RFC cover plate Sprinkler Wrench Model FC (without wrenchable cap) Model W3 (with wrenchable cap) Listings and Approvals cULus Listed to UL 1626 cULus Certified for Health Effects to NSF/ANSI Standard 61 Annex G (RFC30LL only) Model RFC30 & RFC30LL Sprinkler Components and Dimensions Bottom View 2-5/16" (58 mm) . Threads Dia. Body - - - Cup Tower 1-3/4" (44 mm) +/- 1/4" (6 mm) Fusible Link Nominal face of fitting to ceiling Deflector (retracted) Pin (extended) II II Deflector (extended) Model RFC Cover Plate 3-5/16" (84 mm) Dia. Model RFC30 and RFC30LL Sprinkler Hvdraulic Desiqn Criteria 3/16" (5 mm) Ceiling Minimum Flow and Residual Pressure Max. Coverage Area (2) Flow Pressure ft. x ft. gpm psi (m x m) (1/min) (bar) 12 x 12 9 9.0 (3.6 x 3.6) (34) (0.62) 14x 14 10 11.0 (4.3 x 4.3) (38) (0.76) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table B above and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 006 ��';��'� Page 2 of 8 December 2018 www.reliablesprinkler.com Technical Specifications Style: Flat Concealed Pendent Threads: 1/2" NPT or ISO 7-1 R1/2 Nominal K-Factor: 4.3 (62 metric) Max. Working Pressure: 175 psi (12 bar) Min. Spacing: 8 ft. (2.4 m) Material Specifications Thermal Sensor: Nickel Alloy Solder Link Sprinkler Body: Brass Alloy Levers: Bronze Alloy Yoke: Brass Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Towers: Copper Alloy Pins: Stainless Steel Deflector: Bronze Alloy Cup: Steel Cover Plate Finishes (See Table H) Sensitivity Fast -response Temperature Rating 165°F (74°C) sprinkler 135°F (57°C) cover plate Cover Plate Model RFC cover plate Sprinkler Wrench Model FC (without wrenchable cap) Model W3 (with wrenchable cap) Listings and Approvals cULus Listed to UL 1626 cULus Certified for Health Effects to NSF/ANSI Standard 61 Annex G (RFC43LL only) Model RFC43 & RFC43LL Sprinkler Components and Dimensions Bottom View i h' 2-5/16" (58 mm) y Threads Dia. Body _ Cup Tower 1-3/4" (44 mm) +!- 1/4" (6 mm) Fusible Link Nominal face of fitting to ceiling Deflector (retracted) Pin (extended) Deflector (extended)i - ti Model RFC Cover Plate 3-5/16" (84 mm) Dia. Model RFC43 & RFC43LL Sprinkler Hydraulic Design Criteria 3/16" (5 mm; Ceiling Minimum Flow and Residual Pressure Max. Coverage Area (2) Flow Pressure ft. x ft. gpm psi (m x m) (1/min) (bar) 15 x 15 12 7.8 (4.6 x 4.6) (45) (0.54) 16 x 16 13 9.1 (4.9 x 4.9) (49) (0.63) 18 x 18 18 17.5 (5,5 x 5.5) (68) (1.21) 20 x 20 21 23.8 (6.1 x 6.1) (79) (1.64) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table C above and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 006 ��';��'� Page 3 of 8 December 2018 www.reliablesprinkler.com Technical Specifications Style: Flat Concealed Pendent Threads: 1/2" NPT or ISO 7-1 R1/2 Nominal K-Factor: 4.9 (71 metric) Max. Working Pressure: 175 psi (12 bar) Min. Spacing: 8 ft. (2.4 m) Material Specifications Thermal Sensor: Nickel Alloy Solder Link Sprinkler Body: Brass Alloy Levers: Bronze Alloy Yoke: Brass Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Towers: Copper Alloy Pins: Stainless Steel Deflector: Bronze Alloy Cup: Steel Sensitivity Fast -response Temperature Rating Ordinary: 165°F (74°C) sprinkler 135°F (57°C) cover plate Intermediate: 212°F (100°C) sprinkler 165°F (74°C) cover plate Cover Plate Model RFC cover plate Sprinkler Wrench Model FC (without wrenchable cap) Model W3 (with wrenchable cap) Cover Plate Finishes Listings and Approvals cULus Listed to UL 1626 (See Table H) cULus Certified for Health Effects to NSF/ANSI Standard 61 Annex G (RFC49LL only) Model RFC49 & RFC49LL Sprinkler Components and Dimensions Threads — Body Cup Tower Fusible Link — Deflector (retracted) Pin (extended) Deflector (extended) - 1-3/4" (44 mm) +/- 1/4" (6 mm) Nominal face of fitting to ceiling i Bottom View 2-5/16" (58 mm) Dia. Model RFC Cover Plate ­' i� 3-5/16" (84 mm) Dia. Model RFC49 & RFC49LL Sprinkler Hydraulic Design Criteria 3/16" (5 mm; Ceiling Minimum Flow and Residual PressureM Max. Coverage Area (Z) Ordinary Temperature Intermediate Temperature Flow Pressure Flow Pressure ft. x ft. (m x m) gpm psi gpm psi (1/min) (bar) (1/min) (bar) 16 x 16 13 7.0 13 7.0 (4.9 x 4.9) (49.0) (0.48) (49.0) (0.48) 18 x 18 17 12.0 17 12.0 (5.5 x 5.5) (64.3) (0.83) (64.3) (0.83) 20 x 20 20 16.7 21 18.4 (6.1 x6.1) (75.7) (1.15) (79.5) (1.27) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table D above and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 006 ��';��'� Page 4 of 8 December 2018 www.reliablesprinkler.com Technical Specifications Cover Plate Finishes Style: Flat Concealed Pendent (See Table H) Threads: 1/2" NPT or ISO 7-1 R1/2 Nominal K-Factor: 5.8 (84 metric) Sensitivity Max. Working Pressure: 175 psi (12 bar) Fast -response Min. Spacing: 8 ft. (2.4 m) Temperature Ratings Material Specifications Ordinary: Thermal Sensor: Nickel Alloy Solder Link 165°F (74°C) sprinkler Sprinkler Body: Brass Alloy 135°F (57°C) cover plate Levers: Bronze Alloy Intermediate: Yoke: Brass Alloy 212°F (100°C) sprinkler Sealing Assembly: Nickel Alloy with PTFE 165°F (74°C) cover plate Load Screw: Bronze Alloy Towers: Copper Alloy Cover Plate Pins: Stainless Steel Model RFC Cover Plate Deflector: Chrome Plated Bronze Alloy Cup: Steel Sprinkler Wrench Model FC Listings and Approvals cULus Listed Model RFC58 Sprinkler Components and Dimensions Threads — Body Cup Tower Fusible Link — Deflector (retracted) Pin (extended) Deflector (extended) - 1-7/8" (48 mm) +/- 3/8" (9 mm) Nominal face of fitting to ceiling Model RFC Cover Plate Model RFC58 Sprinkler Hydraulic Design Criteria Bottom View 2-5/16" (58 mm) Dia. F3/16" (5 mm) Ceiling Minimum Flow and Residual Pressure') Max. Coverage Area (2) Flow Pressure ft. x ft. gpm psi (m x m) (1/min) (bar) 16 x 16 16 7.6 (4.9 x 4.9) (60.6) (0.53) 18 x 18 18 9.6 (5.5 x 5.5) (68.1) (0.66) 20 x 20 20 11.9 (6.1 x 6.1) (75.7) (0.82) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table E above and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 006 ��';��'� Page 5 of 8 December 2018 www.reliablesprinkler.com Technical Specifications Cover Plate Finishes Style: Flat Concealed Pendent (See Table H) Threads: 3/4" NPT or ISO 7-1 R3/4 Nominal K-Factor: 7.6 (109 metric) Sensitivity Max. Working Pressure: 175 psi (12 bar) Fast -response Min. Spacing: 8 ft. (2.4 m) Temperature Ratings Material Specifications Ordinary: Thermal Sensor: Nickel Alloy Solder Link 165°F (74°C) sprinkler Sprinkler Body: Brass Alloy 135°F (57°C) cover plate Levers: Bronze Alloy Intermediate: _ Yoke: Brass Alloy 212°F (100°C) sprinkler -. Sealing Assembly: Nickel Alloy with PTFE 165°F (74°C) cover plate Load Screw: Bronze Alloy Towers: Copper Alloy Cover Plate Pins: Stainless Steel Model RFC Cover Plate Deflector: Bronze Alloy Cup: Steel Sprinkler Wrench Bottom View(7) Model FC Listings and Approvals cULus Listed Model RFC76 Sprinkler Components and Dimensions ThreE Body Cup Towei Fusible Li Deflector (retra Pin (extern Deflector (extend 1-7/8" (48 mm) +/- 3/8" (9 mm) Nominal face of fitting to ceiling Model RFC Cover Plate Model RFC76 Flat Concealed Sprinkler Hydraulic Design Criteria 2-5/16" (58 mm) Dia. 3-5/16" (84 mm) Dia. 3/16" (5 mm) Ceiling Minimum Flow and Residual PressureN Max. Coverage Area (2) Flow Pressure ft. x ft. gpm psi (m x m) (1/min) (bar) 16 x 16 21 7.6 (4.9 x 4.9) (79.5) (0.52) 18 x 18 24 9.9 (5.5 x 5.5) (90.8) (0.68) 20 x 20 34 20 (6.1 x 6.1) (128.7) (1.4) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table E above and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 006 Page 6 of 8 December 2018 Heliabld www.reliablesprinkler.com Cover Plate FinishesM Standard Finishes Special Application Finishes White Polyester Off White Paint Black Paint Raw Brass Chrome Plated Bright Brass Finished Bronze Black Plated Satin Chrome Stainless Steel Clad (3) Custom Color Paint(2) Notes: 1. Paint or any other coating applied over the factory finish will void all approvals and warranties. 2. Custom color paint is semi -gloss, unless specified otherwise. 3. Stainless steel clad cover plates are Type 316 Stainless Steel on the finished side and C102 Copper Allow on the backside. Cover plates are not listed or approved as corrosion resistant. Stainless steel clad cover plates are not available perforated. Installation Dimensions Recommended Min. to Min. to Max. Sprinkler Cover Cover Plate Hole Diameter Cover Plate Max. Face Dropped Deflector Cover Plate Model Plate Diameter in Ceiling Adjustment of Fitting to Distance below Temperature Model inch (mm) inch (mm) inch (mm) Ceilings') Ceiling Rating inch (mm) inch (mm) RFC30, RFC30LL, RFC 3-5/16 2-5/8 1/2 1-1/2 to 2 1/2 to 1 1350F RFC43, (84) (67) (13) (38 to 51) (13 to 25) (57°C) RFC43LL 1350F(2) RFC49, RFC 3-5/16 2-5/8 1/2 1-1/2 to 2 1/2 to 1 (57°C) RFC49LL (84) (67) (13) (38 to 51) (13 to 25) or 1650F3 (74°C) 1350F(2) RFC58, RFC 3-5/16 2-5/8 3/4 1-1/2 to 2-1/4 1/4 to 1 (57°C) RFC76 (84) (67) (19) (38 to 57) (6 to 25) or 1650F(3) (74°C) Notes: 1. Face of fitting to ceiling dimensions are based on a nominal thread make up. Verify dimensions based on fitting and thread sealing method prior to installation. A 1/2" x 1/2" brass nipple extension (Reliable P/N 6999991900) is available where necessary for replacement of existing sprinklers. 2. For use with 165°F (74°C) temperature rated sprinklers where the Maximum Ceiling Temperature does not exceed 100°F (38°C). 3. For use with 212°F (100°C) temperature rated sprinklers with the Maximum Ceiling Temperature does not exceed 150°F (66°C). Installation Model RFC series sprinklers are intended to be installed in ac- cordance with NFPA 13, NFPA 13R, or NFPA 13D, as well as the requirements of applicable authorities having jurisdiction. Mod- el RFC series sprinklers must not be installed in ceilings with positive pressure in the space above. Ensure that the 4 slots in the cup are open and unobstructed following installation. Model RFC series sprinklers are shipped with a protective cap that should remain on the sprinkler until installed. The protective cap should be replaced following installation of the sprinkler and permanently removed only when the cover plate is installed and the sprinkler system is placed in service following construction. Model RFC series sprinklers are installed with the Model FC wrench. The use of any other wrench to installed Model RFC se- ries sprinklers is not permitted and may damage the sprinkler. Temporarily remove the protective cap during installation of the sprinkler. Insert the Model FC wrench over the sprinkler until the wrench engages the body. Do not wrench any other part of the sprinkler/cup assembly. The Model FC wrench is designed to be turned with a standard 1/2" square drive. Tighten the sprin- kler into the fitting after applying a PTFE based thread sealant to the sprinkler's threads. Recommended installation torque is 8 to 18 ft-Ibs (11 to 24 N-m) for 1/2" thread sprinklers and 14 to 20 ft-Ibs (19 to 27 N-m) for 3/4" thread sprinklers. Do not exceed the maximum recommended torque. Exceeding the maximum recommended torque may cause leakage or im- pairment of the sprinkler. Use care when inserting or removing the wrench from the sprinkler to avoid damage to the sprinkler. Install the cover plate by hand by pushing the cover plate into the cup and turning the cover in the clockwise direction until it is tight against the ceiling. Application Model RFC series sprinklers are intended for installation where residential sprinklers are permitted or required by NFPA 13, NFPA 13R, and NFPA 13D. The sprinklers are concealed pen- dent residential sprinklers. Model RFC 30, RFC30LL, RFC43, and RFC43LL sprinklers are available in ordinary temperature classification for installation where the Maximum Ceiling Temperature does not exceed 100OF (380C). Model RFC49, RFC49LL, RFC58, and RFC76 sprinklers are available in either ordinary or intermediate tem- perature classification for installation where the Maximum Ceiling Temperature does not exceed 100OF (38°C) or 150OF (660C), respectively. Bulletin 006 December 2018 Page 7 of 8 www.reliablesprinkler.com Model FC For use with Models RFC30, RFC43, and RFC 49 without wrenchable cap and Models RFC58 and RFC76 Maintenance Model RFC series sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by gentle vacuuming. Replace any sprinkler cover plate assembly which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replace- ment of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non -oper- ation. Listings and Approvals Listed by Underwriters Laboratories, Inc. and UL Certified for Canada to UL1626, Residential Sprinklers for Fire -protection Service (cULus). Certified by Underwriters Laboratories, Inc. and Underwriters Laboratories of Canada for Health Effects to NSF/ANSI Standard 61 Annex G (LL) (RFC30LL, RFC43LL, and RFC49LL only). ra r Model W3 For use with Models RFC30, RFC43, and RFC49 with wrenchable cap Guarantee For the Reliable Automatic Sprinkler Co., Inc. guarantee, terms, and conditions, visit www.reliablesprinkler.com. Patents Model RFC30, RFC30LL, RFC43, RFC43LL, RFC49, RFC49LL, RFC58, and RFC76 sprinklers are covered by U.S. Patent No. 9,248,327 and U.S. Patent No. 7,275,603. Model RFC30, RFC30LL, RFC43 and RFC43LL sprinklers are additionally covered by U.S. Patent No. 8,776,903. Ordering Information Specify the following when ordering. Sprinkler • Model (RFC30, RFC30LL, RFC43, RFC43LL, RFC49, RFC49LL, RFC58, RFC76) • Temperature Rating Cover Plate • Model RFC • Temperature Rating • Finish (See Table H) Sprinkler Wrench • Model FC • Model W3 M Bulletin 006 �e1i��1e Page 8 of 8 December 2018 www.reliablesprinkler.com Bulletin 157 Rev. I Features 1. The Model F3QR sprinkler utilizes Belleville Spring Closure Technology. Reliable is the first in the industry to produce a Quick Response Dry Concealed sprin- kler utilizing this technology. 2. Styles available • Pendent • Recessed FP Pendent • Recessed F1 Pendent • Concealed • Horizontal Sidewall • Recessed FP Horizontal Sidewall • Recessed F1 Horizontal Sidewall 3. 11/2" (38mm) escutcheon adjustment on pendent sprinkler. 4. 1/2" (13mm) escutcheon adjustment on recessed sprin- kler with push -on/ thread -off FP Model Escutcheon ring. 5. 3/8" (9.5mm) cover plate adjustment on concealed sprinkler with push -on/ thread -off CCP Cover Plate. 6. 3/4" (19mm) escutcheon adjustment on recessed sprinkler with F1 Escutcheon. 7. Attractive appearance. Employs 3mm frangible glass bulb and galvanized nipple. 8. Lengths available to accommodate installation di- mensions from 2" - to - 48" (51 mm - to - 1219mm), in '/4" (6mm) increments. See specific styles for correct "A" dimension range. 9. Available in a variety of plated and painted finishes. 10.Polyester Coated Corrosion Resistant Sprinklers. US Patent Numbers 5,775,431 and 5,967,240. Other US Patents pending. Approvals 1. Listed by Underwriters Laboratories Inc. and UL Certified for Canada (cULus) Style Response Sprinkler System Type Hazard Pendent Recessed Pendent Wet Pipe Light Recessed F1 Pendent Quick Dry Pipe Ordinary CCP Concealed All Preaction (R5714) Horizontal Sidewall Wet Pipe Recessed Horizontal Sidewall Quick Dry Pipe Light (R5734) All Preaction 2. Certified by FM Approvals Style Response Sprinkler System Type Hazard Pendent Wet Pipe Light Ordinary, Recessed F1 Pendent Quick Dry Pipe Groups (R5714) All Preaction 1&2 Horizontal Sidewall Wet Pipe Recessed F1 Horizontal Sidewall Quick Dry Pipe Light (R5734) All Preaction 3. NYC MEA 258-93-E Model F3QR Quick Response Dry Sprinklers iK14 1-0 Pendent (See Fig. 1) Recessed FP Pendent (See Fig. 3) Recessed F1 Pendent (See Fig. 5) Recessed FP Horizontal Sidewall (See Fig. 8) Pendent / HB (See Fig. 2) Concealed (See Fig. 4) Horizontal Sidewall (See Fig. 6) I ^ Horizontal Sidewall / HB (See Fig. 7) Recessed F1 Horizontal Sidewall (See Fig. 9) The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Model F3QR Dry Pendent Sprinkler Model F30R Dry Pendent w/HB Escutcheon "A" Dim. 2" to 48" (51 mm to 1219mm) in %" (6mm) increments "A" Dim. 31/2" to 48" 89mm to 1219mm in 1/4" 6mm increments Finicha4m(1) Sprinkler Escutcheon Bronze Brass (3) Chrome Plated Chrome Plated White Polyester (2) White (1) Other finishes and colors are available on special order. Consult factory for details. (2) cULus Listed as a Corrosion Resistant sprinkler in standard Black or White. (3) Not available for HB escutcheons. F====- ___ ____-= �F===� I r- System Tee 1" NPT 772 /8" Dia. 4.0mm] "A" Dimension Hole in Ceiling Adjustment Range -1/4" [-6.4mm] 1 43/64" Dia. +1 1/4" [+31.8mm] [42.5mm] 1 1/2" [38.1mm] Total Adjustment Sprinkler Can Ceiling 1 1/4" [31.8mm] 1/4" [6.4mm] Escutcheon Escutcheon Ceiling Adjustment Nominal Position 1 5/8 of Escutcheon [41.3mm] 1/4" [6.4mm] Protrusion 3" Dia. [76.2mm] NEW157FG01 Fig. 1 Note: The sprinkler can protrudes 1/4" when escutcheon is in nominal position. Escutcheon adjustment provides -1/4" (-6mm) to +11/4" (+32mm) "A" dimension adjustment range. Sprinkler Guard: Model C-2 Sprinkler Installation Wrench: Model F3 Sprinkler Wrench Sprinkler Identification Number (SIN): R5714 Model F30R Dry Recessed FP Pendent Sprinkler "A" Dim. 31/2" to 48" 89mm to 1219mm in 1/4" 6mm increments Finicha¢]'j Sprinkler Escutcheon Bronze Brass Chrome Plated Chrome Plated White Polyester (2) White (1) Other finishes and colors are available on special order. Consult factory for details. Cup remainds unfinished. Only the escutcheon will contain desired finish. (2) cULus Listed as a Corrosion Resistant sprinkler in standard Black or White. Standard Temperature Ratings Sprinkler Max. Classification Temperature Ambient Bulb Color Rating Temp. Ordinary 135-F (57oC) 100-F (38oC) Orange Ordinary 155-F (68oC) 100oF (38oC) Red Intermediate (1) 175oF (79oC) 150oF (66oC) Yellow Intermediate 200OF (93oC) 150OF (66oC) Green High c1j 2860F 141-C 225oF 107oC Blue Sprinkler cup and FP Escutcheon fabricated of steel and recommended for interior applications. MListed and Certified only by cULus. Standard Temperature Ratings Sprinkler Max. Classification Temperature Ambient Bulb Color Ratin Ordinary 135-F (57oC) 100oF (38oC) Orange Ordinary 155-F (68oC) 100oF (38oC) Red Intermediate (1) 175oF (79oC) 150oF (66oC) Yellow Intermediate 200-F (93oC) 150oF (66oC) Green High (1) 286oF 141-C 225oF 107oC Blue Sprinkler can and escutcheon fabricated of brass for better weather resistance in exterior applications. (1) Listed and Certified only by cli Lr-JL System Tee "A" Dimension 2 1/2" [63.5mm] 1" NPT Adjustment Range Dia. Hole in Ceiling -1/2" [-12.7mm] 3 1/2" [88.9mm] +1/2" [+12.7mm] Escutheon Dia. 1/2" [12.7 Escutheon Adl Adj. Ceiling 1" [25 4, Escutcheon Total Adj. TNV1�/2�[12.7mm] Escutheon Adj. .min Position Sprinkler Can f Escutcheon 1-1/4" [31.75mm] 1 5/8" Nominal Protrusion [41.3mm] 2 13/64" [55.88mm] Dia. —1— Fig. 2 Note: The sprinkler can protrudes 11/4" when escutcheon is in nomi- nal position. Escutcheon adjustment provides -1/2" (-12.7mm) to +1/2" (+12.7mm) "A" dimension adjustment range. h�l - � System Tee 2 1/2" Dia. [63.50mm] "A" Dimension Hole in Ceiling Adjustment Range 31/4" 2 19/64" Dia. [36.35mm] [58.34mm] Nominal Position of Escutcheon 1Ceiling Escutcheon Adjustment 1/4" [6.35mm] 3 7/32" Dia. Escutcheon AdjustmentL [81.76mm] 1/2" [12.7mm] Total Adjustment 1" APT Sprinkler Cup Assembly Escutcheon Ceiling NEW157FG03 Fig. 3 Note: Do not install the Model F3QR Dry Recessed FP Pendent Sprin- kler in ceilings which have positive pressure in space above. Sprinkler Installation Wrench: Model XL02 Sprinkler Wrench Sprinkler Identification Number (SIN): R5714 2. Model F3QR Dry Pendent Concealed Sprinkler "A" Dim. 31/z" to 48" (89mm to 1219mm) in 1/4" (6mm) increments ['_[_P rnuor Plata (1) Pinishac 121 Standard Finishes Special Application Finishes Chrome Plated Bright Brass Plated White Black Plated Black Paint Off White Satin Chrome Utilizes the 1/2" cover plate with 3/8" total adjustment. 2> Other finishes and colors are available on special order. Consult factory for details. Standard Temperature Ratings Sprinkler Cover Plate Max. Classification Temperature Temp. Rating Ambient Rating Temp. Ordinary 135°F (57°C) 135-F (57oC) 100-F (38oC) Ordinary 155°F (68°C) 135-F (57oC) 100-F (38oC) Intermediate (1) 175'F (79'C) 165oF (74oC) 150oF (66oC) Intermediate 200°F (93°C) 165-F (74oC) 150-F (66oC) High (1) 286°F (141°C) 165-F (74aC) 150-F (66aC) Sprinkler cup fabricated of steel and CCP Cover Plate fabricated of brass and recommended for interior applications. (1) Listed and Certified only by cULus. Sprinkler Installation Wrench: Model XL02 Sprinkler Wrench Sprinkler Identification Number (SIN): R5714 Model F3QR Dry Recessed F1 Pendent Sprinkler "A" Dim. 31/2" to 48" (89mm to 1219mm) in 1/4" (6mm) increments Finichpc (1) Sprinkler Escutcheon Collar Chrome Plated White Polyester (2) Chrome Plated White Chrome Plated White (1) Other finishes and colors are available on special order. Consult factory for details. (2) cULus Listed as a Corrosion Resistant sprinkler in standard Black or White. Standard Temperature Ratings Sprinkler Max. Classification Temperature Ambient Bulb Color Rating Temp. Ordinary 135-F (57oC) 100-F (38oC) Orange Ordinary 155-F (68oC) 100-F (38oC) Red Intermediate (1) 175oF (79oC) 150'F (66oC) Yellow Intermediate 200-F (93oC) 150-F (66oC) Green High (1) 286aF (141aC) 225'F (107'C) Blue (1) Listed and Certified only by cULus. Sprinkler Installation Wrench: Model XL02 Sprinkler Wrench Sprinkler Identification Number (SIN): R5714 - IiIIH -I I- iHlll - � �- System Tee 1" NPT 2 1/2" Dig. [6.35mm] "A" Dimension Hole in Ceiling Adjustment Range f 3/16" 2 19/64" Dig. [t4.76mm] [58.34m m] Nominal Position of Coverplate Sprinkler Cup Assembly Coverplate Ceiling Assembly Ceiling 3/16" [4.76mm] Coverplate Adjustment 3/16" [4.76mm] 3 5/16" Di, Coverplate Adjustment [84.13mm] 3/8" [9.53mm] Total Adjustment NEW157FG04 Fig. 4 Note: Do not install the Model F3QR Dry Concealed Pendent Sprinkler in ceilings which have positive pressure in the space above. 2 1/2" Dig. [63.50mm] Hole in Ceiling "A" Dimension Adjustment Range t 1/4" [t6.35mm] Nominal Position of Escutcheon Ceiling 1/4" [6.35] C Escutcheon Adjustment 1/4" [6.35] Escutcheon Adjustment 1/2" [12.7mm] Adjustment System Tee 1" NPT 15/16" [49.2mm] 15/16" [23.8mm Sprinkler Cup Assembly 1 /8" Ceiling [3.2mm] Escutcheon 2 27/32" NEW757FG05 [72.2mm] Fig. 5 3. Model F3QR Dry Horizontal Sidewall Sprinkle Model F3QR Dry HSW w/HB Escutcheon "A" Dim. 2" to 48" 51mm to 1219mm in 1/4" 6mm increments "A" Dim. 31/2" to 48" 89mm to 1219mm in 1/4" 6mm increments Finishes"' Sprinkler Escutcheon Bronze Brass (3) Chrome Plated Chrome Plated White Polyester (2) White (1) Other finishes and colors are available on special order. Consult factory for details. (2) cLILus Listed as a Corrosion Resistant sprinkler in standard Black or White. (3) Not available for HB escutcheons. 1 1/2" [38.1omm] Total Adjustment Ceiling r = T 4" [101.60mm] Mir 1 1/4" [31.75mm] 12" [304.80mm] M Escutcheon Adjustment System Tee Escutcheon Adjustment " NET L3. mm] 3" [76.20mm] 2 1/8" Dia. — [53.98man] 3 Hole in Wall 1/4" [6.35mm] Sprinkler Can Protrusion "A" Dimension Adjustment Nominal Position Range — 1/4" [-6.35mm] of Escutcheon mewrs�rcoe + 1 1/4 [+31.75mm] Fig. 6 Note: The sprinkler can protrudes 1/4" when escutcheon is in nominal position. Escutcheon adjustment provides '/4" (-6mm) to +11/4" (+32mm) "A" dimension adjustment range. (1) Listed and Certified only by cULus. Sprinkler Installation Wrench: Model F3 Sprinkler Wrench prinkler Identification Number (SIN): R5734 Standard Temperature Ratings Sprinkler Max. Classification Temperature Ambient Bulb Color Rating Temp. Ordinary 1350F (570C) 100-F (38oC) Orange Ordinary 1550F (68oC) 100oF (38oC) Red Intermediate (1) 175oF (79oC) 150oF (66oC) Yellow Intermediate 200OF (93oC) 150OF (66oC) Green High 2860E 141oC 225oF 107oC Blue Sprinkler can and escutcheon fabricated of brass for better weather resistance in exterior applications. 1" [25.4mm] Total Adjustment Ceiling 1/2" [12.7mm] Escutcheon Adjustment 4" [101.60mm] Min. 1/2" [12.7mm] 12" [304.80mm] Max. Escutcheon Adjustment 2 3/32" System Tee 3 [53.18mm] I 1" NPT [SS.SBmm] [88.9mm] Did. Escutcheon Did. 2 1/2" Did. [63.5mm] Hole in Wall 1-1/4" [31.75mm] Nominal Protrusion "A" Dimension Sprinkler Can Is Adjustment Newrn 7 Range + 1/2' [+12.7mm] - 1/2" [-12.7mm] Nominal Position of Escutcheon Fig. 7 Note: The sprinkler can protrudes 11/4" when escutcheon is in nomi- nal position. Escutcheon adjustment provides -1/2" (-12.7mm) to +1/2" (+12.7mm) "A" dimension adjustment range. Model F3QR Dry Recessed FP Horizontal Sidewall Sprinkler "A" Dim. 31/z" to 48" (89mm to 1219mm) in 1/4" (6mm) increments Finishes (" Sprinkler Escutcheon Bronze Brass Chrome Plated Chrome Plated White Polyester (2) White (1) Other finishes and colors are available on special order. Consult factory for details. Cup remainds unfinished. "See page 2" (2) cULus Listed as a Corrosion Resistant sprinkler in standard Black or White. Standard Temperature Ratings Classification Sprinkler Tem- perature Rating Max. Ambient Temp. Bulb Color Ordinary 135-F (570C) 1000F (38oC) Orange Ordinary 155-F (68oC) 1000F (38oC) Red Intermediate (1) 175oF (790C) 1500F (66oC) Yellow Intermediate 200-F (930C) 150OF (66oC) Green High (1) 286-F (1410C) 225oF (1070C) Blue (1) Listed and Certified only by cLlLus. Sprinkler Installation Wrench: Model XL02 Sprinkler Wrench Sprinkler Identification Number (SIN): R5734 F Ceiling 1 13/32" Escutcheon [35.7mm] 4" [1( imm]Min. Cup 3 12" [304."r,]Max.'* �1" NPT --- -- - 37/32" Did. [[ ��m] 2 5r Did. [63.3.Smm] = Nominal Position Hole Wall 3 of Escutcheon 2 19/64" Di.. [58.3mm] 1/4" Escutcheon Adjustment "A" Dimension Adjustment Range 1 t0 [ Adjus] i1/4' Escutcheon Adjustment [36.35mm] 1/4" [6,351 Escutcheon Adjustment =k • FOR FACTORY MUTUAL (FM) • 4" - 6" FOR UNDERWRITERS LABORATORIES (UL) Fig. 8 Notes: Do not install the Model F3QR Dry Recessed FP Horizontal Sidewall Sprinkler in walls which have positive pressure in their side space. • Listed by cULus for Quick Response. Approved by FM for Standard Response. • Recessed Horizontal sidewall sprinklers are listed with cLlLus for installation of min. 4" (100mm) - to - max. 6" (150mm) below ceiling and approved by FM for installation of min. 4" (100mm) - to - max. 12" (300mm) below ceiling. 91 Model F3QR Dry Recessed F1 Horizontal Sidewall Sprinkler "A" Dim. 31/2" to 48" (89mm to 1219mm) in 1/4" (6mm) increments Finishes (1) Sprinkler Escutcheon Collar Chrome Plated White Polyester (2) Chrome Plated White Chrome Plated White (1) Other finishes and colors are available on special order. Consult factory for details. (2) cl-Lus Listed as a Corrosion Resistant sprinkler in standard Black or White. Standard Temperature Ratings Sprinkler Max. Classification Temperature Ambient Bulb Color Rating Temp. Ordinary 135-F (57oC) 100oF (38oC) Orange Ordinary 155-F (68oC) 100oF (38oC) Red Intermediate (1) 175oF (79oC) 150oF (66oC) Yellow Intermediate 200-F (93oC) 150oF (66oC) Green High (1) 286aF (141aC) 225oF (107oC) Blue (1) Listed and Certified only by cULus. Sprinkler Installation Wrench: Model XL02 Sprinkler Wrench Sprinkler Identification Number (SIN): R5734 Technical Data: Orifice Size:'/z" (15mm) Thread Size: 1" NPT per ANSI B2.1 Working Pressure: 175 psi (12 bar) Nominal K Factor - US / (Metric): 5.6 / (80) Product Description Reliable Model F3QR Dry Sprinklers are quick response sprinklers utilizing a durable 3mm frangible glass bulb. This quick response enables these sprinklers to apply water to a fire much sooner than standard response sprinklers of the similar temperature rating. Model F3QR Dry Sprinklers are intended for use in dry and preac- tion systems and in areas subjected to freezing temperatures, such as freezers and unheated portions inside and outside buildings. Environments wherein dry sprinklers are employed can be cor- rosive. For this reason, Model F3 Sprinklers have a special wax fillet placed in the gap between the cup that supports the bulb and the wrenching boss. This wax will not interfere with the operation of the sprinkler, and it prevents contaminents from entering the internal portion of the drop nipple. The wax must not be removed. Operation The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely manufactured glass capsule. This glass bulb is specially constructed to provide fast thermal response. When the temperature increases sufficiently, due to a fire, the bulb shatters allowing operating parts to clear the waterway. This enables the inlet seal to release air or water and subsequently, cause water flow over the deflector in a uniform spray pattern, controlling or extinguishing the fire. F Ceiling 1 Escutcheon �^1 [3.2mm] 4" [101.6mm]1Ain.3 �= System Tee Sprinkler Cup Assembly 1" NPT 12" [304.8mm]Max. ref 1 2 27/32" [72.2mm] << _ \� 2 1/2" Din.�—� 63.5mm] Hole in Wall -a Nominal Position 1 15/16" [^- of Escutcheon [49.2mm] 1/4" [6.35] Escutcheon Adjustment "A" Dimension 1/2" [12.7mm] NEW157FG09 Adjustment Range Adjustment 31/4" [t6.35mm] 1/4" [6.35] Escutcheon Adjustment # • FOR FACTORY MUTUAL (FM) • 4" — 6" FOR UNDERWRITERS LABORATORIES (UT) Fig. 9 Listed by cULus for Quick Response. Approved by FM for Standard Response. Recessed Horizontal sidewall sprinklers are listed with cULus for installation of min. 4" (100mm) - to - max. 6" (150mm) below ceiling and approved by FM for installation of min. 4" (100mm) - to - max. 12" (300mm) below ceiling. Ordering Information Specify: 1. Sprinkler Type (select one): (a) Model F3QR Dry Pendent (b) Model F3QR Dry Pendent/HB (c) Model F3QR Dry Recessed FP Pendent (d) Model F3QR Dry Recessed F1 Pendent (e) Model F3QR Dry Concealed Pendent (f) Model F3QR Dry Horizontal Sidewall (g) Model F3QR Dry Horizontal Sidewall/HB (h) Model F30R Dry Recessed FP Horizontal Sidewall (i) Model F30R Dry Recessed F1 Horizontal Sidewall 2. Sprinkler Temperature Rating. 3. Sprinkler Finish. 4. Escutcheon type (F1 or FP). 5. Cover Plate/Escutcheon Finish. 6. Length: "A" Dimension (face of tee to face of ceiling or wall) in'/4" (6mm) increments. 7. Model F3QR Dry Pendent (a) is available without sprinkler can and escutcheon. Note: 1. The "A" dimension is based on a nominally gauged pipe thread "make-up" of 0.600" (15mm) per ANSI B2.1 [71/2 threads approximately]. 2. All platings and paintings are decorative and intend- ed for interior use. 5. General Installation Instructions Model F3QR dry sprinklers must be installed only in stan- dard (ANSI B 16.3 class 150 and ANSI B 16.4 class 125) pipe tees in the horizontal position, even at branch line ends. They should not be installed into elbows or pipe couplings located on drop nipples to the sprinklers. For these and other fittings including CPVC*, the dry sprinkler should be installed into a fitting to allow protrusion into the fitting in ac- cordance with the diagrams. The "A" dimension of the dry sprinkler, which extends into the freezers or a freezing zone from wet pipe systems, should be selected to provide, as a minimum, the specified lengths in inches shown in Fig. 10. Caution: Do not install Model F3QR Dry sprinklers into CPVC adapter fittings or tees that have an internal obstruction. This will damage the sprinkler and /or the fitting. Refer to Fig. 11. During installation, the following steps must be followed 1. Cut the specified size hole (see illustrations) for the sprin- kler in the ceiling or wall directly in line with the tee. 2. Apply pipe joint compound to the 1" (25mm) pipe threads and install sprinkler using the Model F3 or XLO2 Sprinkler Wrench as specified. 3. Install the Model FP push -on / thread -off escutcheon or CCP cover plate if required. Note: Installation of the Model F3QR Sprinklers is not rec- ommended in copper pipe systems, as this may reduce the life expectancy of the sprinklers. Model F30R Concealed and Recessed In- stallation Instructions • The Model XLO2 wrench (Fig. 12) is designed to lo- cate on the wrenching pads of the recessed sprin- kler while centering in the cup. A standard'/2" drive ratchet may be used to drive this wrench. Fig. 13 and Fig. 14 show sequentially the insertion of the wrench. First the wrench, with its jaws above the sprinkler de- flector, is moved laterally until centered with the cup. Then raise the wrench inside of the cup until its jaws engage the sprinkler's square wrenching pads (Fig. 14). To remove the wrench, follow this procedure in reverse order. Care should be taken to avoid striking the deflector, with the wrench. • Model F3 Wrench (Fig. 15) is used for installation of Pendent and Horizontal Sidewall sprinklers. • Glass bulb sprinklers have orange bulb protectors to minimize bulb damage during shipping, handling and installation. REMOVE THIS PROTECTION AT THE TIME THE SPRINKLER SYSTEM IS PLACED IN SER- VICE FOR FIRE PROTECTION. Removal of the pro- tectors before this time may leave the bulb vulnerable to damage. RASCO wrenches are designed to install sprinklers when covers are in place. REMOVE PRO- TECTORS BY UNDOING THE CLASP BY HAND. DO NOT USE TOOLS TO REMOVE THE PROTECTORS. Maintenance The Model F30R Quick Response Dry Sprinklers should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not remove the factory applied thermally sensitive wax fillet between the bulb sup- porting cup and the wrenching boss. Do not replace this wax with a substitute substance. An Alternate substance may interfere with proper operation of the sprinkler. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gently vacuuming. Remove any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper opera- tion or non -operation. Caution: Use specified by RASCO wrenches only, which are designed to engage sprinkler's wrenching pad. (Fig. 15, page 9) RECOMMENDED EXPOSED MINIMUM BARREL LENGTH BASED ON AMBIENT TEMPERATURE IN THE PROTECTED AREA (STANDARD DRY PENDENT SPRINKLER SHOWN) AMBIENT TEMPERATURE OF PROTECTED AREA" AT THE DISCHARGE END OF THE SPRINKLER EXPOSED BARREL AMBIENT TEMPERATURE 40'F/4'C I 50'F/101C I 60'F/16'C EXPOSED MINIMUM BARREL LENGTH** (FACE OF TEE TO TOP OF CEILING) IN. MM IN. MM IN. (MM) 40-F (,VC) 0 0 0 30-F (-1'C) 0 0 0 20-F (-TC) 4 (101) 0 0 10-F (-ITC) 8 (203) 1 (25.1) 0 O'F (-IVC) 12 (305) 3 (75) 0 -10'F (-23'C) 14 (356) 4 (101) 1 (25.1) -29F (-29'C) 14 (356) 6 (152) 3 (75) -30'F (-34'C) 16 (406) 8 (203) 4 (101) -40'F (-40'C) 18 (457) 8 (203) 4 (101) -50-F (-46'C) 20 (508) 10 (254) 6 (152) -60-F (-51'C) 20 (508) 10 (254) 6 (152) WET _JIWL1__L__ I 1 MINIMUM OSED (HEATED AREA) EXP BARREL LENGTH i 'A' CLEARANCE DIMENSION HOLE x I • THE PROTECTED AREA REFERS TO THE AREA BELOW THE CEILING. I THE AMBIENT TEMPERATURE IS THE TEMPERATURE AT THE DISCHARGE END OF THE SPRINKLER. FOR PROTECTED AREA TEMPERATURES THAT OCCUR BETWEEN THE VALUES USTED, USE THE NEXT COOLER TEMPERATURE. -THE MIN. REQUIRED BARREL LENGTH IS NOT THE SAME AS THE 'A' DIMENSION. NOTE: EXPOSED MINIMUM BARREL LENGTHS ARE INCLUSIVE UP TO 30MPH CEILING WIND VELOCITIES IN THE PROTECTED AREA (PROTECTED AREA) INSTALL 1 INCH NPI THREADED END OF DRY PENDENT SPRINKLER INTO THE 1 INCH NPI SIDE OUTLET OF A MALLEABLE IRON TEE FITTING PER ANSI B 16.3 CLASS 150) OR CAST IRON THREADED TEE FITTING PER ANSI 16.4 (CLASS 125) ONLY. IF HUMIDITY AND TEMPERATURE DIFFERENTIAL CAUSES CONDENSATION ON THE EXPOSED DRY SPRINKLER, CONSIDER WRAPPING THE EXPOSED BARREL WITH INSULATION, FOAM INSULATING TAPE OR EQUIVALENT. SEAL THE CLEARANCE SPACE AROUND THE SPRINKLER TO AVOID LEAKAGE OF AIR INTO THE PROTECTED AREA AND CONSEQUENT FORMATION OF CONDENSATE AROUND THE FRAME, WHICH COULD INHIBIT OPERATION OR CAUSE PREMATURE OPERATION. SEE BELOW FOR RECOMMENDED METHODS. ESCUTCHEON 1-3" DIA�I *RECOMMENDED EXPOSED MINIMUM BARREL LENGTHS ALSO APPLY TO HORIZONTAL SIDEWALL DRY SPRINKLERS* RECOMMENDED DRY SPRINKLER SEAL ARRANGEMENTS WET PIPE (STANDARD DRY PENDENT SPRINKLER SHOWN) WET PIPE 1 VIA-7-1 1i L j L J (HEATED AREA) (HEATED AREA) MINIMUM MINIMUM EXPOSED EXPOSED BARREL 1 BARREL LENGTH DECKTITE FLASHING _j INSIDE FACE SEAL LENGTH (SEE ABOVE) RASCO #4003910 I (SEE ABOVE) (RECOMMENDED) 1 CLEARANCE HOLE 1 INSULATED FREEZER 1 I OR COOLER STRUCTU4RE .......... . .::'. .'.:'. .'. I '.': .':.':.'::.':.'::.':.': .' OR EXTERIOR FRAMIN ...................... , ................... (PROTECTED AREA) III I� A DRY SPRINKLER V f�1:1 /IV IN COLD AREA Fig. 10 7. (PROTECTED AREA) DRY SPRINKLER IN COLD AREA NEW157FG10 *CAUTION* DO NOT INSTALL MODEL F3, MODEL F3QR OR MODEL DH56 HSW DRY SPRINKLERS INTO CPVC ADAPTER FITTINGS OR TEES THAT HAVE AN INTERNAL OBSTRUCTION. THIS WILL DAMAGE THE SPRINKLER AND/OR THE FITTING. CPVC ADAPTER FITTINGS AND TEES WITH INTERNAL OBSTRUCTIONS ARE ALSO COMMONLY FOUND DURING THE RETROFITTING PROCESS OF RELIABLE'S OLDER MODEL G3 DRY SPRINKLERS. INTERNAL NO OBSTRUCTION INTERNAL OBSTRUCTION FEMALE FEMALE PIPE PIPE . THREAD THREAD INCORRECT CORRECT CPVC ADAPTER CPVC ADAPTER FITTING OR TEE FITTING OR TEE 1 SHORTER LONGER INLET INLET MALE MALE PIPE PIPE THREAD THREAD MODEL F3-PL, MODEL F3QR-PL OR STANDARD MODEL DH56 HSW-PL MODEL F3, DRY SPRINKLER MODEL F3QR OR MODEL DH56 HSW DRY SPRINKLER BE SURE TO ORDER THE CORRECT SPRINKLERS FOR YOUR APPLICATION 016fgO8A Fig. 11 m Fig. 12 - XL02 Wrench Fig. 13 - XL02 Wrench 15- Fig. 14 - XL02 Wrench 0 Reliable ... For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many precision -made Reliable products that guard life and property from fire around the clock. • Automatic sprinklers • Flush automatic sprinklers • Recessed automatic sprinklers • Concealed automatic sprinklers • Adjustable automatic sprinklers • Dry automatic sprinklers • Intermediate level sprinklers • Open sprinklers • Spray nozzles • Alarm valves • Retarding chambers • Dry pipe valves • Accelerators for dry pipe valves • Mechanical sprinkler alarms • Electrical sprinkler alarm switches • Water flow detectors • Deluge valves • Detector check valves • Check valves • Electrical system • Sprinkler emergency cabinets • Sprinkler wrenches • Sprinkler escutcheons and guards • Inspectors test connections • Sight drains • Ball drips and drum drips • Control valve seals • Air maintenance devices • Air compressors • Pressure gauges • Identification signs • Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured b Reliable The Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address ®Recycled Paper Revision lines indicate updated or new data. EG. Printed in U.S A. 12112 P/N 9999970175