ENG2022-0361 ROW PERMITRIGHT OF WAY EUC PERMIT
City •Edmonds
Edmonds98020 1 1
www.cityofedmonds.gov / i
Description: COMCAST - MUTIPLE SPLICE LOCATIONS 9TH AND HINDLEY
ISSUED: 08/22/2022
Address: 802 DRIFTWOOD LN EDMONDS WA 98020-2632
EXPIRES:02/22/2023
Permit Type: RIGHT OF WAY EUC Permit Subtype: MINOR Parcel Number: 27031300303700
CONTACTS
NAME TYPE NAME ADDRESS PHONE
APPLICANT OWEN SHACKEET 410 VALLEY AVE NW, PUYALLUP WA 98371 (253)341-9318
CONTACT CABLECOM LLC 19910 NORTHCREEK PARKWAY N„ BOTHELL WA 98011 (360)454-3163
CONTRACTOR CABLECOM LLC 20021 120TH AVE NE, SUITE 101, BOTHELL WA 98011 (360)863-2628
OWNER WILLIAM R JR VOLPENTEST PO BOX 77568, SEATTLE WA 98177
FEE INFORMATION
DESCRIPTION AMOUNT PAID
CITY TECHNOLOGY FEE CHARGED PER PERMIT $40.00 $40.00
ENGINEERING INSPECTION FEE $220.00 $220.00
RIGHT OF WAY MINOR - EUC PERMIT FEE $110.00 $110.00
REQUIREMENTS
REQUIREMENT TYPE
NOTES
TRAFFIC CONTROL Traffic control and public safety shall be in accordance with City regulations as required by the City
Engineer. Every flagger must be trained as required by WAC 296-155-305 and must have certification
verifying completion of the required training in their posession.
RESTORATION Restoration is to be in accordance with City codes. All street -cut trench work shall be patched with
asphalt or City approved material prior to the end of the workday - No Exceptions
WARRANTY The contractor is responsible for workmanship and materials for a period of one year following the final
inspection and acceptance of the work.
INSPECTION SCHEDULING: WWW.MYBUILDING PERMIT.COM
24 HR NOTICE REQUIRED
The Applicant has signed an application which states he/she holds the City of Edmonds harmless from injuries, damages or claims of
any kind or description whatsoever, foreseen or unforeseen, that may be made against the City of Edmonds or any of its departments
or employees, including but not limited to the defense of any legal proceedings including defense costs and attorney fees by reason of
granting this permit.
THIS DOCUMENT IS NOT VALID UNTIL FEES ARE PAID AND THE CITY ENGINEER OR HIS/HER DEPUTY HAS SIGNED BELOW
08/22/2022
RELEASED BY
DATE
Printed: Monday, August 22, 2022 9:16:12 AM 1 of 2
oe e n,y
RIGHT OF WAY EUC PERMIT
PERMIT NU�M
City of Edmonds
EdmondsAd
98020 1 1
www.cityofedmonds.gov / i
CONDITIONS
CONDITION TYPE
NOTES
ALERT RESIDENTS
ALERT AFFECTED RESIDENTS AND OR BUSINESSES PRIOR TO WORK START.
It is the owner's responsibility to repair/replace all damage of utilities or frontage improvements in
DAMAGE TO FRONTAGE
City right of Ways or Easements to City Standards caused by or occurring during the permitted
IMPROVEMENTS
project.
MAINTAIN EROSION AND SEDIMENTATION CONTROL PER CITY AND SWMMW STANDARD
ESC REQUIREMENTS
REQUIREMENTS.
Applicant, on behalf of his or her spouse, heirs, assigns, and successors in interests, agrees to
indemnify defend and hold harmless the City of Edmonds, Washington, its officials, employees, and
agents from any and all claims for damages of whatever nature, arising directly or indirectly from the
HOLD HARMLESS
issuance for this permit. Issuance of this permit shall not be deemed to modify, waive or reduce any
requirements of any City ordinance nor limit in any way the City's ability to enforce any ordinance
provision.
SCHEDULE REQUIRED INSPECTIONS AS NOTED THROUGH MY BUILDING PERMIT.
INSPECTIONS
www.mybuildingpermit.com
POTHOLING
VERIFY CLEAR BORE CROSSINGS.
RESTORE LANDSCAPE
Restore landscape to like or better conditions
Sound or noise originating from temporary construction sites as a result of construction activity are
exempt from the noise limits of ECC Chapter 5.30 only during the hours of 7:00am to 6:00pm on
SOUND AND NOISE
weekdays and 10:00am and 6:00pm on Saturdays, excluding Sundays and Federal Holidays. At all
other times the noise originating from construction sites and activities must comply with the noise
limits of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120.
All utilities shall be located prior to any excavation. New locates shall be called for if at time of
UTILITY LOCATES
excavation, original locates are no longer identifiable.
INSPECTIONS
INSPECTION TYPE
DATE RESULT
NOTES
COMPLETE
A-1 JOB START
E-7 TRAFFIC CTRL
X-2 ENGINEERING FINAL"
Printed: Monday, August 22, 2022 9:16:12 AM 2 of 2
RECEIVED
Lti�y of ED%�O�
ANC. 1 g90
SECTION A
RIGHT OF WAY CONSTRUCTION
PERMIT APPLICATION
Complete and submit this Application in accordance with the Submittal
Requirements outlined in Right -of -Way permit Handout E63.
J U L 11 2022
CITY OF EDMONDS
DEVELOPMENT
SERVICES DEPARTMENT
If any field is not applicable to your project, write "N/A" instead of leaving blank.
All fields required. Incomplete Applications will be denied.
General•
Project Name COMCAST - JB0000994769 - 1
Site Address or if no site address use Property Address at NW corner of project area: 802 DRIFTWOOD LN, EDMONDS, WA 98020
Associated Permits: BLD PLN ENG
Owner and Entity Holding Franchise (if applicable)
Name ofCompanyCOMCAST CABLE HOLDING Franc hiseOrdinanceNo:
Point of Contact OWEN SHACKETT
Title PERMIT COORDINATOR
Address 410 VALLEY AVE NW
City PUYALLUP
State WA
Zip 98371
Phone253-341-9318
EmailOWEN SHACKETT@CABLE.COMCAST.COM
Contractor and Authorized Agent of • • - •• •w)
Name of CompanyCABLECOM LLC
Contractor ContactsDuring Construction
Primary Name CABLECOM LLC - MICHAEL FINCH
Agent Name SUNSHINE CRABBS
Title CONSTRUCTION SUPERVISOR
Title PERMIT COORDINATOR
Mobile 360-965-5085
Address 19910 NORTHCREEK PARKWAY NORTH, SUITE 100
Email MICHAEL.FINCH@CABLECOMLLC. NET
City BOTHELL
State WA
Zip 98011
Secondary Name
Phone 360-454-3163
Title
Email SUNSHINE.CRABBS@CABLECOMLLC. NET
Mobile
City of Edmonds Business License No: N R - 021818
Email
State License No: CABLEL*971 DP
56 Contractor verifies it is currently bonded
Contractor verifies it currently has general liability insurance
NOTE: ECDC 18.6o.02o requires that the Application be signed by a licensed and bonded contractor unless otherwise approved by the city
engineer.
❑ Multifamily residential ❑ Commercial ❑ City project
❑ Single family residential subdivision ❑ Single family -other ❑ Industrial
❑ Demo and rebuild or from vacant land?
❑ Other, please specify:
❑ Utility Franchise Work associated with development (check one of the above boxes as well)
❑ Traffic Control Only (no associated development)
City of Edmonds ROW construction permit Application --Page 1 of 3 Updated 3/25/2021
vttility Franchise Work (no associated development)
Project Description
Include an overall narrative description of the proposed work. Be specific and detailed:
Describe infrastructure to be impacted, such as, poles, wires, conduit, utility mains, etc.
Include whether this is construction, maintenance, or repair.
Include description of proposed construction methods, (e.g., bores, trenches, overhead wires proposed, depth for
underground utilities, etc.)
MAINTENACE SPLICES AT EXSITING AERIAL AND GROUND CASES AT THE FOLLOWING 9 LOCATIONS: NO NEW CONSTURCTION,
Aerial
1
902 DRIFTWOOD LN
Aerial
2
14029TH AVE N
Aerial
3
14009TH AVE N
Aerial
4
800 PUGET LN
Aerial
5
742 MELODY LN
Aerial
6
815HINDLEYUN
Aerial
7
906 PUGET WAY
Ped
8
902 MNDLEY LN
Aerial
9
9, BROOKMERE 5T
RIGHT-OF-WAY
CLOSURE
AREA
TOTAL
DURATION
(Number of Months)
Sidewalk 72 hours +
LF
JxJ
LF
SF
Alley 72 hours +
LF
I x
I LF
SF
Parking 72 hours +
I LF
JxJ
LF
I SF
SECTION B - If you are not a utility company performing work in the City ROW, skip to SECTION C.
1. The work in the right of way is on or for the following type of facilities:
❑ telecommunications d cable ❑ power ❑ gas
❑ water ❑ sewer ❑ storm
1.
CompletedDetails of Work to be
Does the utility owner have existin overhead infrastructure in the area of work?
x
•
2.
Will any equipment be added underground or above ground (e.g. pedestals, vaults, etc.)?
x
If yes, describe:
3.
Does the proposed work connect a lot or commercial development with utilities that serve more
than one lot or commercial development?
X
4.
Does the work involve rebuilding or relocating an existing aboveground utility system which
connects a lot or commercial development to an existing underground common utility system?
X
5.
Does the work involve proposed additions to an aboveground utility system? If es:
x
Are the additions for the purpose of serving new commercial development?
Are the additions for the purpose of serving a single-family residential subdivision?
Details of • to be Completed
®i
6. Does your project involve rebuilding or replacing utility equipment which currently serves more
than one lot or commercial development?
X
City of Edmonds ROW construction permit Application --Page 2 of 3 Updated 3/25/2021
If yes, answer the following questions related to project area, i.e. the actual area in which the
project is proposed:
6a.
Does your project involve wires/cables/lines? If yes:
How many are existing? I I How many are to be added?
6b.
Does your project involve poles? If yes:
How many poles are existing in the project area?
What is the height of the existing poles?
How many poles are to be removed?
Are additional poles to be laced?
How many? I I What is the height of the additionalpoles?
6c.
Are any poles to be modified/rebuilt/replaced? If yes:
How many? What is the height of the poles after?
Describe the modification rebuild:
SECTION C
Traffic Control and Public Safety. Traffic control and public safety shall be in accordance with City regulations as
required by the City Engineer. Every flagger must be trained as required by WAC 296-155-305 and must have
certification verifying completion of the required training in their possession.
Restoration. Restoration shall be in accordance with City codes and Standards. All street cut trench work shall be
patched with asphalt or City approved material prior to the end of the workday -NO EXCEPTIONS.
Insurance. The City may require the owner or contractor to provide proof of insurance acceptable to the City prior to
any permit approval.
Indemnification. The Applicant agrees to defend, indemnify, and hold harmless the City of Edmonds, its officials,
officers, employees, and agents against any injuries, damages, or claims of any kind or description whatsoever,
foreseen or unforeseen, including defense costs and attorney fees, resulting directly or indirectly from any act or
omission of the Applicant, its subcontractors, anyone directly or indirectly employed by them, and anyone for whose
acts or omissions they may be liable, arising out of, related to, or by reason of the granting of this permit; and
specifically including but not limited to all loss by the failure of the Applicant to fully or adequately perform, in any
respect, all authorizations or obligations under the permit. These indemnification requirements shall survive the
expiration, revocation, or termination of any resulting permit approval.
Acceptance of terms, conditions, and requirements. Applicant accepts the terms, conditions, and
requirements set forth in this Application and agrees they apply to any resulting permit and shall comply with them to
the satisfaction of the City Engineer. Applicant further agrees to comply with the conditions listed on the Submittal
Requirements; with all applicable city ordinances, including but not limited to ECDC Title 18; and with all applicable
requirements of state and federal law.
Statement of Applicant. I declare under penalty of perjury under the laws of the State of Washington that: I am a
licensed and bonded contractor; the information provided herein is correct and complete; and I am authorized by
owner to act on its behalf and have authority to bind the owner to this application.
Fees. The Applicant is responsible for all permit fees.
APPLICANT SIGNATURE: , 6"d4/a C24A6� DATE: 07/08/2022
APPLICANT PRINTED NAME: Sunshine Crabbs
APPLICANT TITLE: PERMIT COORDINATOR
NO WORK SHALL BEGIN PRIOR TO PERMIT ISSUANCE
City of Edmonds ROW construction permit Application --Page 3 of 3 Updated 3/25/2021
Route Overview
Completed By:
0
�r
�-
W ,: ,. SE
`
S
Completion Date:
1/0/1900
Address:
I 802 DRIFTWOOD LN, EDMONDS, WA98020
I
COMCAST
Survey Revision Date:
Survey Revision Task ID:
Footages Entered On Right of Way, Private Exterior, and Private Interior tabs. Footages
are summarized on Survey Rollup tab._
Engineered For:
Project Manager:
Are Additional Pages Needed: No
P2 ID:
JB0000994769
Legend
New Ped
❑
Pole
New Vault
❑�
Lock Box
Existing U/G
Footage
150'
Existing Aerial
Text Box
Text
New U/G
Callout Arrow
lkk
New Aerial
New Tap
A
Interior Path
Phase Identifier
0
Footage Break
Fiber Splice Point
Power Supply
Ps
Storage Loop
W
Hard Surface Cut
O
Riser
®
Abandoned Cable
Provide Clear Construction Details
MULTIPLE MAINTENANCE & SPLICE LOCATIONS AT THE
FOLLOWING ADDRESSES:
Aerial
1
802 DRIFTWOOD LN
Aerial
2
1402 9TH AVE N
Aerial
3
1400 9TH AVE N
Aerial
4
800 PUGET LN
Aerial
5
742 MELODY LN
Aerial
6
815 HINDLEY LN
Aerial
7
906 PUGET WAY
Ped
°
902 HINDLEY LN
Aerial
9
915 BROOKMERE ST
SCHEDULE ALL INSPECTIONS THROUGH MYBUILDINGPERMIT.COM
—T Broo'r'Kn'1%re St
ENGINEERING DIVISION
APPROVED AS NOTED
jell Wj,4j,$,44 08/11/2022
VV
CZ'
v
0
J U L 11 2022
CITY OF EDMONDS
DEVELOPMENT
SERVICES DEPARTMENT
Ford
<D
Q
Exce
U
Q
,
O
Asbuilt Cover
Completed By:
0
f-%r
,�
r_
E
W ,: ,. E
`
S
Completion Date:
1/0/1900
Address:
I 802 DRIFTWOOD LN, EDMONDS, WA 98020
I
COMCAST
Survey Revision Date:
Survey Revision Task ID:
Footages Entered On Right of Way, Private Exterior, and Private Interior tabs. Footages
are summarized on Survey Rollup tab._
Engineered For:
Project Manager:
-
Are Additional Pages Needed: No
P2 ID:
JB0000994769
Legend
New Ped
❑
Pole
New Vault
❑V
Lock Box
Existing U/G
Footage
150'
Existing Aerial
Text Box
Text
New U/G
Callout Arrow
New Aerial
New Tap
Interior Path
Phase Identifier
❑1
Footage Break
Fiber Splice Point
Power Supply
Ps
Storage Loop
Hard Surface Cut
O
Riser
®
Abandoned Cable
Provide Clear Construction Details
MULTIPLE MAINTENANCE & SPLICE LOCATIONS AT THE
FOLLOWING ADDRESSES:
Aerial
1
802 DRIFTWOOD LN
Aerial
2
1402 9TH AVE N
Aerial
3
1400 9TH AVE N
Aerial
4
800 PUGET LN
Aerial
5
742 MELODY LN
Aerial
6
815 HINDLEY LN
Aerial
7
906 PUGET WAY
Ped
8
902 HINDLEY LN
Aerial
1 9
915 BROOKMERE ST
tit e1 o cty L n
. r �
C �
k I i t
Pu aot Dr
1 %
Pugh W I� r�
Hmdley Lis
z =
I -
� I
St
BrookMefe
- �- viewmoor PI
I
r
L RECEIVED -
J U L 11 2022
CITY OF EDMONDS
DEVELOPMENT
SERVICES DEPARTMENT
Hens
SIGN SPACING = X (1)
RURAL ROADS & URBAN ARTERIALS 35 / 40 MPH 350' +/-
R DS, E I
L S I T I
URBAN STREETS 25 MPH OR LESS 100' +/- (2)
(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE
INTERSECTIONS AND DRIVEWAYS.
(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT
ROADWAY CONDITIONS.
]RHOS
MINIMUM SHOULDER TAPER LENGTH = L/3 (feet)
SHOULDER
Posted Speed (mph)
WIDTH
(feet)
25
30
35
40
45
50
55
60
65
70
8'
40
40
60
90
-
-
-
-
-
-
10'
40
60
90
90
USE A 3 DEVICES TAPER FOR SHOULDERS LESS THEN 8'
do 1dS SI ANOZ 2:JOM 2:JAAANAHM ciAa oAd :j
�18 ]]VHS N 110AdSN1 ]O2JiN00 OIJJVd J1
—40- PUGET DR 25 MPH
LEGEND
14 TEMPORARY SIGN LOCATION
CHANNELIZING DEVICES
PROTECTIVE VEHICLE
11 11 �� TI
X X L/3 B"I
48" 48"
ROAD SHOULDER
// <
WORK WORK
AHEAD
48" 48"
W20-1 W21-5
THIS IS A COMCAST DOCUMENT, PROPRIETARY & CONFIDENTIAL
REV DESCRIPTION DATE
DESIGN:
0 ISSUE FOR PERMIT 7/6/2022
DRAWN BY: ERIC
APPROVED:
APPROVED:
APPROVED:
SHOULDER CLOSURE - LOW SPEED
(40 MPH OR LESS)
NOT TO SCALE
BUFFER DATA
LONGITUDINAL BUFFER SPACE = B
SPEED (MPH)
25
30
35
40
45
50
55
60
65
70
LENGTH (feet)
155
200
250
305
360
425
495
570
645
730
TRANSPORTABLE ATTENUATOR ROLL AHEAD DISTANCE = R
HOST VEHICLE WEIGHT
9,900 TO 22,000 Ibs.
HOST VEHICLE WEIGHT
> 22,000 Ibs.
< 45 MPH
45-55 MPH
> 55 MPH
< 45 MPH
45-55 MPH
> 55 MPH
100'
123'
172'
74'
100'
150,
PROTECTIVE VEHICLE (WORK VEHICLE) = R
NO SPECIFIED DISTANCE REQUIRED
IMPORTANT NOTICE
Section # 4216/4217 of the Government Code requires a Dig Alert
Identification Number to be issued before a "Permit to Excavate" will be
valid For your Dig Alert I.D.
CALL TOLL FREE
48 HOURS BEFORE YOU DIG
UNDERGROUND SERVICE ALERT
1-800-227-2600
CHANNELIZATION DEVICE
SPACING (feet)
MPH
TAPER
TANGENT
35/40
30
60
25/30
20
40
50'
NOTES
1. DEVICE SPACING FOR THE 13U@ZW60TAR
2. ALL SIGNS ARE BLACK ON ORANGE.
a310N SV GDA021ddV
NOISIAId DNI J33NIJN3
-W
SCALE: N.T.S
802 DRjFff_QQ0I,JgWh98020
TpkA**kdk-
PROJ#: JB994769
CONSTRUCTION TYPE: MAINTENANCE SPLICE
SYSTEM: EDMONDS
EMAIL: ERIC.MCDOWELL@CABLECOMa
J U L 11 2022
TC-3
SHEET: 3 OF 7
PIN
SIGN SPACING = X (1)
RU R S & RT 4 /-
RU D U 2 / /_
RESIDENTIAL &BUSINESS DISTRICTS
URBAN STREETS 25 MPH OR LESS 100' +/- (2)
(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE
INTERSECTIONS AND DRIVEWAYS.
(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT
ROADWAY CONDITIONS.
e
)S
X
MINIMUM SHOULDER TAPER LENGTH = L/3 (feet)
SHOULDER
Posted Speed (mph)
WIDTH
(feet)
25
30
35
40
45
50
55
60
65
70
8'
40
40
60
90
-
-
-
-
-
-
10'
40
60
90
90
1 _
I _
_
_
_
-
USE A 3 DEVICES TAPER FOR SHOULDERS LESS THEN 8'
9TH AVE N 25 MPH
e
X
48"
ROAD <WO>RK
WORK HEAD48"
W20-1 W21-5
do 1dS SI ANOZ N2:10M 2:JAAANAHM aA2:jinOA2i
38 ��VHS NOIlO�IdSNI �O2JiNOO OIJJV J1
LEGEND
14 TEMPORARY SIGN LOCATION
CHANNELIZING DEVICES
PROTECTIVE VEHICLE
THIS IS A COMCAST DOCUMENT, PROPRIETARY & CONFIDENTIAL
REV DESCRIPTION DATE
DESIGN:
0 ISSUE FOR PERMIT 7/6/2022
DRAWN BY: ERIC
APPROVED:
APPROVED:
APPROVED:
i
SHOULDER CLOSURE - LOW SPEED
(40 MPH OR LESS)
NOT TO SCALE
BUFFER DATA
LONGITUDINAL BUFFER SPACE = B
SPEED (MPH)
25
30
35
40
45
50
55
60
65
70
LENGTH (feet)
155
200
250
305
360
425
495
570
645
730
TRANSPORTABLE ATTENUATOR ROLL AHEAD DISTANCE = R
HOST VEHICLE WEIGHT
9,900 TO 22,000 Ibs.
HOST VEHICLE WEIGHT
> 22,000 Ibs.
< 45 MPH
45-55 MPH
> 55 MPH
< 45 MPH
45-55 MPH
> 55 MPH
100'
123'
172'
74'
100'
150,
PROTECTIVE VEHICLE (WORK VEHICLE) = R
NO SPECIFIED DISTANCE REQUIRED
IMPORTANT NOTICE
Section # 4216/4217 of the Government Code requires a Dig Alert
Identification Number to be issued before a "Permit to Excavate" will be
valid For your Dig Alert I.D.
CALL TOLL FREE
48 HOURS BEFORE YOU DIG
UNDERGROUND SERVICE ALERT
1-800-227-2600
CHANNELIZATION DEVICE
SPACING (feet)
MPH
TAPER
TANGENT
35/40
30
60
25/30
20
40
50'
NOTES
ZZOZ/ 11/90
1. DEVICE SPACING FOR THE DOWNSTREAM TAPER SHALL B ' F
2. ALL SIGNS ARE BLACK ON ORANGEQ310N SV GDA021dd`d
NOISIAId ON12J33NIJN3
#<ESH�-
SCALE: N.T.S
802 DRjFff_QQ0I,JgWh98020
TpkA**kdk-
PROJ#: JB994769
CONSTRUCTION TYPE: MAINTENANCE SPLICE
SYSTEM: EDMONDS
EMAIL: ERIC.MCDOWELL@CABLECOMa
J U L 11 2022
TC-2
SHEET: 2 OF 7
BUFFER DATA
LONGITUDINAL BUFFER SPACE = B
SPEED (MPH)
25
30
35
40
45
50
55
60
65
70
LENGTH (feet)
155
200
250
305
360
425
495
570
645
730
TRANSPORTABLE ATTENUATOR ROLL AHEAD DISTANCE = R
HOST VEHICLE WEIGHT
9,900 TO 22,000 Ibs.
HOST VEHICLE WEIGHT
> 22,000 Ibs.
< 45 MPH
45-55 MPH
> 55 MPH
< 45 MPH
45-55 MPH
> 55 MPH
100'
123'
172'
74'
100'
150'
PROTECTIVE VEHICLE (WORK VEHICLE) = R
NO SPECIFIED DISTANCE REQUIRED
DRIFTWOOD LN 25 MPH
a a
X
4
ONE LANE
ROAD
AHEAD
4
48" W20-4
ROAD
WORK
AHEAD
48"
W20-1
LEGEND
FLAGGING STATION
a
TEMPORARY SIGN LOCATION
CHANNELIZING DEVICES
PROTECTIVE VEHICLE
X X X I 50' TO
300'
" . • 48"
BE \
PREPARED
\TO STOP/r
W20-7B
W20-71B (OPTIONAL IF
40 MPH OR LESS)
THIS IS A COMCAST DOCUMENT, PROPRIETARY & CONFIDENTIAL
REV DESCRIPTION DATE
DESIGN:
0 ISSUE FOR PERMIT 7/6/2022
DRAWN BY: ERIC
APPROVED:
APPROVED:
APPROVED:
W20-7A
SIGN SPACING
= X (1)
RURAL HIGHWAYS
60 / 65 MPH
800' +/-
RURAL ROADS
45 / 55 MPH
500' +/-
RURAL ROADS & URBAN ARTERIALS
35 / 40 MPH
350' +/-
RURAL ROADS, URBAN ARTERIALS,
RESIDENTIAL & BUSINESS DISTRICTS
25 / 30 MPH
200' +/- (2)
URBAN STREETS
25 MPH OR LESS
100' +/- (2)
(1) ALL SPACING MAYBE ADJUSTED TO ACCOMMODATE
INTERSECTIONS AND DRIVEWAYS.
(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT
ROADWAY CONDITIONS.
50' TO 100'
6 DEVICE
MIN
AREA
50' TO 100'
6 DEVICE
B MIN.
W20-713 (OPTIONAL IF
40 MPH OR LESS)
48" 48"
BE ROAD
PREPARED WORK
TO STOP HEAD
48" 48" 48" 48"
. W20-713 ONE LANE W20-1
ROAD
AHEAD
48" 48"
W20-7A W20-4
X i X X i X
X 48„
SzLO
•
JN
X 48" 48"
a BE NNN
W20-7A
Q y PREPARED 40 MPH (OPTIONAL IF
Q 40 MPH OR LESS)
0 TO STOP
X 48" 48„
H
IL ONE LANE W20-7B
y ROAD
� AHEAD
X 48" 48"
W20-4 ROAD
CHANNELIZATION DEVICE
SPACING (FEET)
MPH
TAPER
TANGENT
50/65
10 TO 20
80
35/45
10 TO 20
60
25/30
10 TO 20
40
4 WORK NOTES
HEAD
48" 1. ALL SIGNS ARE BLACK ON ORANGE.
W20-1 2. EXTENDING THE CHANNELIZING DEVICE TAPER ACROSS
ONE -LANE, TWO-WAY TRAFFIC CONTROL
WITH FLAGGERS
NOT TO SCALE
IMPORTANT NOTICE
Section # 4216/4217 of the Government Code requires a Dig Alert
Identification Number to be issued before a "Permit to Excavate" will be
valid For your Dig Alert I.D.
CALL TOLL FREE
48 HOURS BEFORE YOU DIG
UNDERGROUND SERVICE ALERT
1-800-227-2600
SHOULDER IS RECOMMENDED.
3. NIGHT WORK REQUIRES ADDITIONAL ROADWAY LIGHTING AT
FLAGGING STATIONS. SEE THE STANDARD SPECIFICATIONS
FOR ADDITIONAL DETAILS.
4. SEE SPECIAL PROVISIONS FOR WORK HOUR RESTRICTIONS.
802 DRjFffMj)@i0rggWR98020
TpkA**ktb-
PROJ#: JB994769
CONSTRUCTION TYPE: MAINTENANCE SPLICE
SYSTEM: EDMONDS
EMAIL: ERIC.MCDOWELL@CABLECOMa
i@T�_
SCALE: N.T.S
J U L 11 2022
TC-1
SHEET: 1 OF
SIGN SPACING = X (1)
RURAL ROADS & URBAN ARTERIALS 35 / 40 MPH
350' +/-
RURAL ROADS, URBAN ARTERIALS, 25 / 30 MPH
200' +/- (2)
RESIDENTIAL & BUSINESS DISTRICTS
URBAN STREETS 25 MPH OR LESS
100' +/- (2)
(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE
INTERSECTIONS AND DRIVEWAYS.
(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT
ROADWAY CONDITIONS.
LEGEND
a TEMPORARY SIGN LOCATION
CHANNELIZING DEVICES
PROTECTIVE VEHICLE
MINIMUM SHOULDER TAPER LENGTH = L/3 (feet)
SHOULDER
Posted Speed (mph)
WIDTH
(feet)
25
30
35
40
45
50
55
60
65
70
8'
40
40
60
90
-
-
-
-
-
-
10'
40
60
90
90
USE A 3 DEVICES TAPER FOR SHOULDERS LESS THEN 8'
MELODY LN 25 MPH
X X L/3 B"I
48" 48"
ROAD SHOULDER
WORK WORK
HEAD
48" 48"
W20-1 XA/91 _F
THIS IS A COMCAST DOCUMENT, PROPRIETARY & CONFIDENTIAL
REV DESCRIPTION DATE
DESIGN:
0 ISSUE FOR PERMIT 7/6/2022
DRAWN BY: ERIC
APPROVED:
APPROVED:
APPROVED:
SHOULDER CLOSURE — LOW SPEED
(40 MPH OR LESS)
NOT TO SCALE
IMPORTANT NOTICE
BUFFER DATA
LONGITUDINAL BUFFER SPACE = B
SPEED (MPH)
25
30
35
40
45
50
55
60
65
70
LENGTH (feet)
155
200
250
305
360
425
495
570
645
730
TRANSPORTABLE ATTENUATOR ROLL AHEAD DISTANCE = R
HOST VEHICLE WEIGHT
9,900 TO 22,000 Ibs.
HOST VEHICLE WEIGHT
> 22,000 Ibs.
< 45 MPH
45-55 MPH
> 55 MPH
< 45 MPH
45-55 MPH
> 55 MPH
100'
123'
172'
74'
100'
150,
PROTECTIVE VEHICLE (WORK VEHICLE) = R
NO SPECIFIED DISTANCE REQUIRED
Section # 4216/4217 of the Government Code requires a Dig Alert
Identification Number to be issued before a "Permit to Excavate" will be
valid For your Dig Alert I.D.
CALL TOLL FREE
48 HOURS BEFORE YOU DIG
UNDERGROUND SERVICE ALERT
1-800-227-2600
CHANNELIZATION DEVICE
SPACING (feet)
MPH
TAPER
TANGENT
35/40
30
60
25/30
20
40
50'
NOTES
1. DEVICE SPACING FOR THE DOWNSTREAM TAPER SHALL BE 20' (FT).
2. ALL SIGNS ARE BLACK ON ORANGE.
-W
SCALE: N.T.S
J U L 11 2022
802 DRjFffj)Q0I,JgWh98020
TpkA**ktb-
PROJ#: JB994769
CONSTRUCTION TYPE: MAINTENANCE SPLICE T`�-4
SYSTEM: EDMONDS l
EMAIL: ERIC.MCDOWELL@CABLECOML SHEET: 4 OF
7
SIGN SPACING = X (1)
RURAL ROADS & URBAN ARTERIALS 35 / 40 MPH
350' +/-
RURAL ROADS, URBAN ARTERIALS, 25 / 30 MPH
200' +/- (2)
RESIDENTIAL & BUSINESS DISTRICTS
URBAN STREETS 25 MPH OR LESS
100' +/- (2)
(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE
INTERSECTIONS AND DRIVEWAYS.
(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT
ROADWAY CONDITIONS.
LEGEND
a TEMPORARY SIGN LOCATION
CHANNELIZING DEVICES
PROTECTIVE VEHICLE
MINIMUM SHOULDER TAPER LENGTH = L/3 (feet)
SHOULDER
Posted Speed (mph)
WIDTH
(feet)
25
30
35
40
45
50
55
60
65
70
8'
40
40
60
90
-
-
-
-
-
-
10'
40
60
90
90
USE A 3 DEVICES TAPER FOR SHOULDERS LESS THEN 8'
HINDLEY LN 25 MPH
a a
X
48" 48"
ROAD <HOULDER
WORK RK
AHEAD
48" 48"
W20-1 W21-5
THIS IS A COMCAST DOCUMENT, PROPRIETARY & CONFIDENTIAL
REV DESCRIPTION DATE
DESIGN:
0 ISSUE FOR PERMIT 7/6/2022
DRAWN BY: ERIC
APPROVED:
APPROVED:
APPROVED:
BUFFER DATA
LONGITUDINAL BUFFER SPACE = B
SPEED (MPH)
25
30
35
40
45
50
55
60
65
70
LENGTH (feet)
155
200
250
305
360
425
495
570
645
730
TRANSPORTABLE ATTENUATOR ROLL AHEAD DISTANCE = R
HOST VEHICLE WEIGHT
9,900 TO 22,000 Ibs.
HOST VEHICLE WEIGHT
> 22,000 Ibs.
< 45 MPH
45-55 MPH
> 55 MPH
< 45 MPH
45-55 MPH
> 55 MPH
100'
123'
172'
74'
100'
150,
PROTECTIVE VEHICLE (WORK VEHICLE) = R
NO SPECIFIED DISTANCE REQUIRED
z
o Z-11110-
(V
X L/3 B"I 50'
SHOULDER CLOSURE — LOW SPEED
(40 MPH OR LESS)
NOT TO SCALE
IMPORTANT NOTICE
Section # 4216/4217 of the Government Code requires a Dig Alert
Identification Number to be issued before a "Permit to Excavate" will be
valid For your Dig Alert I.D.
CALL TOLL FREE
48 HOURS BEFORE YOU DIG
UNDERGROUND SERVICE ALERT
1-800-227-2600
CHANNELIZATION DEVICE
SPACING (feet)
MPH
TAPER
TANGENT
35/40
30
1 60
25/30
20
1 40
NOTES
1. DEVICE SPACING FOR THE DOWNSTREAM TAPER SHALL BE 20' (FT).
2. ALL SIGNS ARE BLACK ON ORANGE.
SCALE: N.T.S
J U L 11 2022
802 DRjFff_QQ0I,JgWh98020
TpkA**kdk-
PROJ#: JB994769
CONSTRUCTION TYPE: MAINTENANCE SPLICE Tr_S
SYSTEM: EDMONDS l J
EMAIL: ERIC.MCDOWELL@CABLECOML SHEET: 5 OF 7
SIGN SPACING = X (1)
RURAL ROADS & URBAN ARTERIALS 35 / 40 MPH
350' +/-
RURAL ROADS, URBAN ARTERIALS, 25 / 30 MPH
200' +/- (2)
RESIDENTIAL & BUSINESS DISTRICTS
URBAN STREETS 25 MPH OR LESS
100' +/- (2)
(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE
INTERSECTIONS AND DRIVEWAYS.
(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT
ROADWAY CONDITIONS.
LEGEND
a TEMPORARY SIGN LOCATION
CHANNELIZING DEVICES
PROTECTIVE VEHICLE
MINIMUM SHOULDER TAPER LENGTH = L/3 (feet)
SHOULDER
Posted Speed (mph)
WIDTH
(feet)
25
30
35
40
45
50
55
60
65
70
8'
40
40
60
90
-
-
-
-
-
-
10'
40
60
1 90
90
USE A 3 DEVICES TAPER FOR SHOULDERS LESS THEN 8'
BROOKMERE ST 25 MPH
X X L/3 B"I
48" 48"
ROAD SHOULDER
WORK WORK
HEAD
48" 48"
W20-1 XA/91 _F
THIS IS A COMCAST DOCUMENT, PROPRIETARY & CONFIDENTIAL
REV DESCRIPTION DATE
DESIGN:
0 ISSUE FOR PERMIT 7/6/2022
DRAWN BY: ERIC
APPROVED:
APPROVED:
APPROVED:
SHOULDER CLOSURE — LOW SPEED
(40 MPH OR LESS)
NOT TO SCALE
IMPORTANT NOTICE
BUFFER DATA
LONGITUDINAL BUFFER SPACE = B
SPEED (MPH)
25
30
35
40
45
50
55
60
65
70
LENGTH (feet)
155
200
250
305
360
425
495
570
645
730
TRANSPORTABLE ATTENUATOR ROLL AHEAD DISTANCE = R
HOST VEHICLE WEIGHT
9,900 TO 22,000 Ibs.
HOST VEHICLE WEIGHT
> 22,000 Ibs.
< 45 MPH
45-55 MPH
> 55 MPH
< 45 MPH
45-55 MPH
> 55 MPH
100'
123'
172'
74'
100'
150,
PROTECTIVE VEHICLE (WORK VEHICLE) = R
NO SPECIFIED DISTANCE REQUIRED
Section # 4216/4217 of the Government Code requires a Dig Alert
Identification Number to be issued before a "Permit to Excavate" will be
valid For your Dig Alert I.D.
CALL TOLL FREE
48 HOURS BEFORE YOU DIG
UNDERGROUND SERVICE ALERT
1-800-227-2600
CHANNELIZATION DEVICE
SPACING (feet)
MPH
TAPER
TANGENT
35/40
30
1 60
25/30
20
1 40
50'
NOTES
1. DEVICE SPACING FOR THE DOWNSTREAM TAPER SHALL BE 20' (FT).
2. ALL SIGNS ARE BLACK ON ORANGE.
SCALE: N.T.S
J U L 11 2022
802 DRjFff_QQ0I,JgWh98020
TpkA**kdk-
PROJ#: JB994769
CONSTRUCTION TYPE: MAINTENANCE SPLICE TC— 7
SYSTEM: EDMONDS
EMAIL: ERIC.MCDOWELL@CABLECOML SHEET: 7 OF
7
RECEIVED
J U L 11 2022
CITY OF EDMONDS
CITY OF EDMONDS MyBuildingPermit.com
DEVELOPMENT
SERVICES DEPARTMENT
Right-Of-wav prrliration #1170485 - COMCAST - JB0000994769 - EDMONDS 1
Applicant
First Name Last Name Company Name
OWEN SHACKEET COMCAST
Number Street Apartment or Suite Number E-mail Address
410 VALLEY AVE NW OWEN SHACKETT@CABLE.COMCAST.
City State Zip Phone Number Extension
PUYALLUP WA 98371 (253) 341-9318
Contractor
Company Name
Cablecom LLC
Number Street Apartment or Suite Number
19910 NORTH CREEK PARKWAY NORTH 100
City State Zip Phone Number Extension
BOTHELL WA 98011 (360) 863-2628 (360) 454-3163
State License Number License Expiration Date UBI # E-mail Address
CABLEL*971 DP 8/21/2023 FD99RSS79 SNOHOMISH.PERM ITTING@CABLECO
Project Location
Number Street Floor Number Suite or Room Number
802 DRIFTWOOD LN
City Zip Code County Parcel Number
EDMONDS 98020 27031300303700
Associated Building Permit Number Tenant Name
Additional Information (i.e. equipment location or special instructions)_
Work Location
Property Owner
First Name Last Name or Company Name
William R Jr Volpentest
Number Street Apartment or Suite Number
PO BOX 77568
City State Zip
SEATTLE WA 98177
Certification Statement - The applicant states:
I certify that I am the owner of this property or the owner's authorized agent. If acting as an authorized agent, I further certify that I have full power and
authority to file this application and to perform, on behalf of the owner, all acts required to enable the jurisdiction to process and review such application. I
have furnished true and correct information. I will comply with all provisions of law and ordinance governing this type of application. If the scope of work
requires a licensed contractor to perform the work, the information will be provided prior to permit issuance.
Date Submitted: 7/8/2022 Submitted By: OWEN SHACKEET
Page 1 of 2
i
CITY OF EDMONDS MyBuildingPermit.com
Right -of -Way Application #1170485 - COMCAST - JB0000994769 - EDMONDS 1
Project Contact
Company CABLECOM LLC
Name:
Name: SUNSHINE CRABBS Email: SUNSHINE.CRABBS@CABLECOMLLC.NET
Address: 19910 NORTHCREEK Phone (360) 454-3163
PARKWAY N, 100 #:
BOTHELL WA 98011
Project Type Activity Type Scope of Work
Utility Purveyor Utility Work No Disturbance of Surface
Project Name: COMCAST - JB0000994769 - EDMONDS 1
MAINTENANCE SPLICES AT EXISTING AERIAL AND GROUND CASES AT THE
Description of FOLLOWING 9 LOCATIONS, 802 DRIFTWOOD LN 1402 9TH AVE N 1400 9TH AVE N 800
Work: PUGET LN 742 MELODY LN 815 HINDLEY LN 906 PUGET WAY 902 HINDLEY LN 915
BROOKMERE ST NO NEW CONSTRUCTIONS IN ALL EXISTING CASES.
Project Details
Project Information
Job Number
JB0000994769
Page 2 of 2