Loading...
ENG2022-0361 ROW PERMITRIGHT OF WAY EUC PERMIT City •Edmonds Edmonds98020 1 1 www.cityofedmonds.gov / i Description: COMCAST - MUTIPLE SPLICE LOCATIONS 9TH AND HINDLEY ISSUED: 08/22/2022 Address: 802 DRIFTWOOD LN EDMONDS WA 98020-2632 EXPIRES:02/22/2023 Permit Type: RIGHT OF WAY EUC Permit Subtype: MINOR Parcel Number: 27031300303700 CONTACTS NAME TYPE NAME ADDRESS PHONE APPLICANT OWEN SHACKEET 410 VALLEY AVE NW, PUYALLUP WA 98371 (253)341-9318 CONTACT CABLECOM LLC 19910 NORTHCREEK PARKWAY N„ BOTHELL WA 98011 (360)454-3163 CONTRACTOR CABLECOM LLC 20021 120TH AVE NE, SUITE 101, BOTHELL WA 98011 (360)863-2628 OWNER WILLIAM R JR VOLPENTEST PO BOX 77568, SEATTLE WA 98177 FEE INFORMATION DESCRIPTION AMOUNT PAID CITY TECHNOLOGY FEE CHARGED PER PERMIT $40.00 $40.00 ENGINEERING INSPECTION FEE $220.00 $220.00 RIGHT OF WAY MINOR - EUC PERMIT FEE $110.00 $110.00 REQUIREMENTS REQUIREMENT TYPE NOTES TRAFFIC CONTROL Traffic control and public safety shall be in accordance with City regulations as required by the City Engineer. Every flagger must be trained as required by WAC 296-155-305 and must have certification verifying completion of the required training in their posession. RESTORATION Restoration is to be in accordance with City codes. All street -cut trench work shall be patched with asphalt or City approved material prior to the end of the workday - No Exceptions WARRANTY The contractor is responsible for workmanship and materials for a period of one year following the final inspection and acceptance of the work. INSPECTION SCHEDULING: WWW.MYBUILDING PERMIT.COM 24 HR NOTICE REQUIRED The Applicant has signed an application which states he/she holds the City of Edmonds harmless from injuries, damages or claims of any kind or description whatsoever, foreseen or unforeseen, that may be made against the City of Edmonds or any of its departments or employees, including but not limited to the defense of any legal proceedings including defense costs and attorney fees by reason of granting this permit. THIS DOCUMENT IS NOT VALID UNTIL FEES ARE PAID AND THE CITY ENGINEER OR HIS/HER DEPUTY HAS SIGNED BELOW 08/22/2022 RELEASED BY DATE Printed: Monday, August 22, 2022 9:16:12 AM 1 of 2 oe e n,y RIGHT OF WAY EUC PERMIT PERMIT NU�M City of Edmonds EdmondsAd 98020 1 1 www.cityofedmonds.gov / i CONDITIONS CONDITION TYPE NOTES ALERT RESIDENTS ALERT AFFECTED RESIDENTS AND OR BUSINESSES PRIOR TO WORK START. It is the owner's responsibility to repair/replace all damage of utilities or frontage improvements in DAMAGE TO FRONTAGE City right of Ways or Easements to City Standards caused by or occurring during the permitted IMPROVEMENTS project. MAINTAIN EROSION AND SEDIMENTATION CONTROL PER CITY AND SWMMW STANDARD ESC REQUIREMENTS REQUIREMENTS. Applicant, on behalf of his or her spouse, heirs, assigns, and successors in interests, agrees to indemnify defend and hold harmless the City of Edmonds, Washington, its officials, employees, and agents from any and all claims for damages of whatever nature, arising directly or indirectly from the HOLD HARMLESS issuance for this permit. Issuance of this permit shall not be deemed to modify, waive or reduce any requirements of any City ordinance nor limit in any way the City's ability to enforce any ordinance provision. SCHEDULE REQUIRED INSPECTIONS AS NOTED THROUGH MY BUILDING PERMIT. INSPECTIONS www.mybuildingpermit.com POTHOLING VERIFY CLEAR BORE CROSSINGS. RESTORE LANDSCAPE Restore landscape to like or better conditions Sound or noise originating from temporary construction sites as a result of construction activity are exempt from the noise limits of ECC Chapter 5.30 only during the hours of 7:00am to 6:00pm on SOUND AND NOISE weekdays and 10:00am and 6:00pm on Saturdays, excluding Sundays and Federal Holidays. At all other times the noise originating from construction sites and activities must comply with the noise limits of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120. All utilities shall be located prior to any excavation. New locates shall be called for if at time of UTILITY LOCATES excavation, original locates are no longer identifiable. INSPECTIONS INSPECTION TYPE DATE RESULT NOTES COMPLETE A-1 JOB START E-7 TRAFFIC CTRL X-2 ENGINEERING FINAL" Printed: Monday, August 22, 2022 9:16:12 AM 2 of 2 RECEIVED Lti�y of ED%�O� ANC. 1 g90 SECTION A RIGHT OF WAY CONSTRUCTION PERMIT APPLICATION Complete and submit this Application in accordance with the Submittal Requirements outlined in Right -of -Way permit Handout E63. J U L 11 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT If any field is not applicable to your project, write "N/A" instead of leaving blank. All fields required. Incomplete Applications will be denied. General• Project Name COMCAST - JB0000994769 - 1 Site Address or if no site address use Property Address at NW corner of project area: 802 DRIFTWOOD LN, EDMONDS, WA 98020 Associated Permits: BLD PLN ENG Owner and Entity Holding Franchise (if applicable) Name ofCompanyCOMCAST CABLE HOLDING Franc hiseOrdinanceNo: Point of Contact OWEN SHACKETT Title PERMIT COORDINATOR Address 410 VALLEY AVE NW City PUYALLUP State WA Zip 98371 Phone253-341-9318 EmailOWEN SHACKETT@CABLE.COMCAST.COM Contractor and Authorized Agent of • • - •• •w) Name of CompanyCABLECOM LLC Contractor ContactsDuring Construction Primary Name CABLECOM LLC - MICHAEL FINCH Agent Name SUNSHINE CRABBS Title CONSTRUCTION SUPERVISOR Title PERMIT COORDINATOR Mobile 360-965-5085 Address 19910 NORTHCREEK PARKWAY NORTH, SUITE 100 Email MICHAEL.FINCH@CABLECOMLLC. NET City BOTHELL State WA Zip 98011 Secondary Name Phone 360-454-3163 Title Email SUNSHINE.CRABBS@CABLECOMLLC. NET Mobile City of Edmonds Business License No: N R - 021818 Email State License No: CABLEL*971 DP 56 Contractor verifies it is currently bonded Contractor verifies it currently has general liability insurance NOTE: ECDC 18.6o.02o requires that the Application be signed by a licensed and bonded contractor unless otherwise approved by the city engineer. ❑ Multifamily residential ❑ Commercial ❑ City project ❑ Single family residential subdivision ❑ Single family -other ❑ Industrial ❑ Demo and rebuild or from vacant land? ❑ Other, please specify: ❑ Utility Franchise Work associated with development (check one of the above boxes as well) ❑ Traffic Control Only (no associated development) City of Edmonds ROW construction permit Application --Page 1 of 3 Updated 3/25/2021 vttility Franchise Work (no associated development) Project Description Include an overall narrative description of the proposed work. Be specific and detailed: Describe infrastructure to be impacted, such as, poles, wires, conduit, utility mains, etc. Include whether this is construction, maintenance, or repair. Include description of proposed construction methods, (e.g., bores, trenches, overhead wires proposed, depth for underground utilities, etc.) MAINTENACE SPLICES AT EXSITING AERIAL AND GROUND CASES AT THE FOLLOWING 9 LOCATIONS: NO NEW CONSTURCTION, Aerial 1 902 DRIFTWOOD LN Aerial 2 14029TH AVE N Aerial 3 14009TH AVE N Aerial 4 800 PUGET LN Aerial 5 742 MELODY LN Aerial 6 815HINDLEYUN Aerial 7 906 PUGET WAY Ped 8 902 MNDLEY LN Aerial 9 9, BROOKMERE 5T RIGHT-OF-WAY CLOSURE AREA TOTAL DURATION (Number of Months) Sidewalk 72 hours + LF JxJ LF SF Alley 72 hours + LF I x I LF SF Parking 72 hours + I LF JxJ LF I SF SECTION B - If you are not a utility company performing work in the City ROW, skip to SECTION C. 1. The work in the right of way is on or for the following type of facilities: ❑ telecommunications d cable ❑ power ❑ gas ❑ water ❑ sewer ❑ storm 1. CompletedDetails of Work to be Does the utility owner have existin overhead infrastructure in the area of work? x • 2. Will any equipment be added underground or above ground (e.g. pedestals, vaults, etc.)? x If yes, describe: 3. Does the proposed work connect a lot or commercial development with utilities that serve more than one lot or commercial development? X 4. Does the work involve rebuilding or relocating an existing aboveground utility system which connects a lot or commercial development to an existing underground common utility system? X 5. Does the work involve proposed additions to an aboveground utility system? If es: x Are the additions for the purpose of serving new commercial development? Are the additions for the purpose of serving a single-family residential subdivision? Details of • to be Completed ®i 6. Does your project involve rebuilding or replacing utility equipment which currently serves more than one lot or commercial development? X City of Edmonds ROW construction permit Application --Page 2 of 3 Updated 3/25/2021 If yes, answer the following questions related to project area, i.e. the actual area in which the project is proposed: 6a. Does your project involve wires/cables/lines? If yes: How many are existing? I I How many are to be added? 6b. Does your project involve poles? If yes: How many poles are existing in the project area? What is the height of the existing poles? How many poles are to be removed? Are additional poles to be laced? How many? I I What is the height of the additionalpoles? 6c. Are any poles to be modified/rebuilt/replaced? If yes: How many? What is the height of the poles after? Describe the modification rebuild: SECTION C Traffic Control and Public Safety. Traffic control and public safety shall be in accordance with City regulations as required by the City Engineer. Every flagger must be trained as required by WAC 296-155-305 and must have certification verifying completion of the required training in their possession. Restoration. Restoration shall be in accordance with City codes and Standards. All street cut trench work shall be patched with asphalt or City approved material prior to the end of the workday -NO EXCEPTIONS. Insurance. The City may require the owner or contractor to provide proof of insurance acceptable to the City prior to any permit approval. Indemnification. The Applicant agrees to defend, indemnify, and hold harmless the City of Edmonds, its officials, officers, employees, and agents against any injuries, damages, or claims of any kind or description whatsoever, foreseen or unforeseen, including defense costs and attorney fees, resulting directly or indirectly from any act or omission of the Applicant, its subcontractors, anyone directly or indirectly employed by them, and anyone for whose acts or omissions they may be liable, arising out of, related to, or by reason of the granting of this permit; and specifically including but not limited to all loss by the failure of the Applicant to fully or adequately perform, in any respect, all authorizations or obligations under the permit. These indemnification requirements shall survive the expiration, revocation, or termination of any resulting permit approval. Acceptance of terms, conditions, and requirements. Applicant accepts the terms, conditions, and requirements set forth in this Application and agrees they apply to any resulting permit and shall comply with them to the satisfaction of the City Engineer. Applicant further agrees to comply with the conditions listed on the Submittal Requirements; with all applicable city ordinances, including but not limited to ECDC Title 18; and with all applicable requirements of state and federal law. Statement of Applicant. I declare under penalty of perjury under the laws of the State of Washington that: I am a licensed and bonded contractor; the information provided herein is correct and complete; and I am authorized by owner to act on its behalf and have authority to bind the owner to this application. Fees. The Applicant is responsible for all permit fees. APPLICANT SIGNATURE: , 6"d4/a C24A6� DATE: 07/08/2022 APPLICANT PRINTED NAME: Sunshine Crabbs APPLICANT TITLE: PERMIT COORDINATOR NO WORK SHALL BEGIN PRIOR TO PERMIT ISSUANCE City of Edmonds ROW construction permit Application --Page 3 of 3 Updated 3/25/2021 Route Overview Completed By: 0 �r �- W ,: ,. SE ` S Completion Date: 1/0/1900 Address: I 802 DRIFTWOOD LN, EDMONDS, WA98020 I COMCAST Survey Revision Date: Survey Revision Task ID: Footages Entered On Right of Way, Private Exterior, and Private Interior tabs. Footages are summarized on Survey Rollup tab._ Engineered For: Project Manager: Are Additional Pages Needed: No P2 ID: JB0000994769 Legend New Ped ❑ Pole New Vault ❑� Lock Box Existing U/G Footage 150' Existing Aerial Text Box Text New U/G Callout Arrow lkk New Aerial New Tap A Interior Path Phase Identifier 0 Footage Break Fiber Splice Point Power Supply Ps Storage Loop W Hard Surface Cut O Riser ® Abandoned Cable Provide Clear Construction Details MULTIPLE MAINTENANCE & SPLICE LOCATIONS AT THE FOLLOWING ADDRESSES: Aerial 1 802 DRIFTWOOD LN Aerial 2 1402 9TH AVE N Aerial 3 1400 9TH AVE N Aerial 4 800 PUGET LN Aerial 5 742 MELODY LN Aerial 6 815 HINDLEY LN Aerial 7 906 PUGET WAY Ped ° 902 HINDLEY LN Aerial 9 915 BROOKMERE ST SCHEDULE ALL INSPECTIONS THROUGH MYBUILDINGPERMIT.COM —T Broo'r'Kn'1%re St ENGINEERING DIVISION APPROVED AS NOTED jell Wj,4j,$,44 08/11/2022 VV CZ' v 0 J U L 11 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Ford <D Q Exce U Q , O Asbuilt Cover Completed By: 0 f-%r ,� r_ E W ,: ,. E ` S Completion Date: 1/0/1900 Address: I 802 DRIFTWOOD LN, EDMONDS, WA 98020 I COMCAST Survey Revision Date: Survey Revision Task ID: Footages Entered On Right of Way, Private Exterior, and Private Interior tabs. Footages are summarized on Survey Rollup tab._ Engineered For: Project Manager: - Are Additional Pages Needed: No P2 ID: JB0000994769 Legend New Ped ❑ Pole New Vault ❑V Lock Box Existing U/G Footage 150' Existing Aerial Text Box Text New U/G Callout Arrow New Aerial New Tap Interior Path Phase Identifier ❑1 Footage Break Fiber Splice Point Power Supply Ps Storage Loop Hard Surface Cut O Riser ® Abandoned Cable Provide Clear Construction Details MULTIPLE MAINTENANCE & SPLICE LOCATIONS AT THE FOLLOWING ADDRESSES: Aerial 1 802 DRIFTWOOD LN Aerial 2 1402 9TH AVE N Aerial 3 1400 9TH AVE N Aerial 4 800 PUGET LN Aerial 5 742 MELODY LN Aerial 6 815 HINDLEY LN Aerial 7 906 PUGET WAY Ped 8 902 HINDLEY LN Aerial 1 9 915 BROOKMERE ST tit e1 o cty L n . r � C � k I i t Pu aot Dr 1 % Pugh W I� r� Hmdley Lis z = I - � I St BrookMefe - �- viewmoor PI I r L RECEIVED - J U L 11 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Hens SIGN SPACING = X (1) RURAL ROADS & URBAN ARTERIALS 35 / 40 MPH 350' +/- R DS, E I L S I T I URBAN STREETS 25 MPH OR LESS 100' +/- (2) (1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERSECTIONS AND DRIVEWAYS. (2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS. ]RHOS MINIMUM SHOULDER TAPER LENGTH = L/3 (feet) SHOULDER Posted Speed (mph) WIDTH (feet) 25 30 35 40 45 50 55 60 65 70 8' 40 40 60 90 - - - - - - 10' 40 60 90 90 USE A 3 DEVICES TAPER FOR SHOULDERS LESS THEN 8' do 1dS SI ANOZ 2:JOM 2:JAAANAHM ciAa oAd :j �18 ]]VHS N 110AdSN1 ]O2JiN00 OIJJVd J1 —40- PUGET DR 25 MPH LEGEND 14 TEMPORARY SIGN LOCATION CHANNELIZING DEVICES PROTECTIVE VEHICLE 11 11 �� TI X X L/3 B"I 48" 48" ROAD SHOULDER // < WORK WORK AHEAD 48" 48" W20-1 W21-5 THIS IS A COMCAST DOCUMENT, PROPRIETARY & CONFIDENTIAL REV DESCRIPTION DATE DESIGN: 0 ISSUE FOR PERMIT 7/6/2022 DRAWN BY: ERIC APPROVED: APPROVED: APPROVED: SHOULDER CLOSURE - LOW SPEED (40 MPH OR LESS) NOT TO SCALE BUFFER DATA LONGITUDINAL BUFFER SPACE = B SPEED (MPH) 25 30 35 40 45 50 55 60 65 70 LENGTH (feet) 155 200 250 305 360 425 495 570 645 730 TRANSPORTABLE ATTENUATOR ROLL AHEAD DISTANCE = R HOST VEHICLE WEIGHT 9,900 TO 22,000 Ibs. HOST VEHICLE WEIGHT > 22,000 Ibs. < 45 MPH 45-55 MPH > 55 MPH < 45 MPH 45-55 MPH > 55 MPH 100' 123' 172' 74' 100' 150, PROTECTIVE VEHICLE (WORK VEHICLE) = R NO SPECIFIED DISTANCE REQUIRED IMPORTANT NOTICE Section # 4216/4217 of the Government Code requires a Dig Alert Identification Number to be issued before a "Permit to Excavate" will be valid For your Dig Alert I.D. CALL TOLL FREE 48 HOURS BEFORE YOU DIG UNDERGROUND SERVICE ALERT 1-800-227-2600 CHANNELIZATION DEVICE SPACING (feet) MPH TAPER TANGENT 35/40 30 60 25/30 20 40 50' NOTES 1. DEVICE SPACING FOR THE 13U@ZW60TAR 2. ALL SIGNS ARE BLACK ON ORANGE. a310N SV GDA021ddV NOISIAId DNI J33NIJN3 -W SCALE: N.T.S 802 DRjFff_QQ0I,JgWh98020 TpkA**kdk- PROJ#: JB994769 CONSTRUCTION TYPE: MAINTENANCE SPLICE SYSTEM: EDMONDS EMAIL: ERIC.MCDOWELL@CABLECOMa J U L 11 2022 TC-3 SHEET: 3 OF 7 PIN SIGN SPACING = X (1) RU R S & RT 4 /- RU D U 2 / /_ RESIDENTIAL &BUSINESS DISTRICTS URBAN STREETS 25 MPH OR LESS 100' +/- (2) (1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERSECTIONS AND DRIVEWAYS. (2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS. e )S X MINIMUM SHOULDER TAPER LENGTH = L/3 (feet) SHOULDER Posted Speed (mph) WIDTH (feet) 25 30 35 40 45 50 55 60 65 70 8' 40 40 60 90 - - - - - - 10' 40 60 90 90 1 _ I _ _ _ _ - USE A 3 DEVICES TAPER FOR SHOULDERS LESS THEN 8' 9TH AVE N 25 MPH e X 48" ROAD <WO>RK WORK HEAD48" W20-1 W21-5 do 1dS SI ANOZ N2:10M 2:JAAANAHM aA2:jinOA2i 38 ��VHS NOIlO�IdSNI �O2JiNOO OIJJV J1 LEGEND 14 TEMPORARY SIGN LOCATION CHANNELIZING DEVICES PROTECTIVE VEHICLE THIS IS A COMCAST DOCUMENT, PROPRIETARY & CONFIDENTIAL REV DESCRIPTION DATE DESIGN: 0 ISSUE FOR PERMIT 7/6/2022 DRAWN BY: ERIC APPROVED: APPROVED: APPROVED: i SHOULDER CLOSURE - LOW SPEED (40 MPH OR LESS) NOT TO SCALE BUFFER DATA LONGITUDINAL BUFFER SPACE = B SPEED (MPH) 25 30 35 40 45 50 55 60 65 70 LENGTH (feet) 155 200 250 305 360 425 495 570 645 730 TRANSPORTABLE ATTENUATOR ROLL AHEAD DISTANCE = R HOST VEHICLE WEIGHT 9,900 TO 22,000 Ibs. HOST VEHICLE WEIGHT > 22,000 Ibs. < 45 MPH 45-55 MPH > 55 MPH < 45 MPH 45-55 MPH > 55 MPH 100' 123' 172' 74' 100' 150, PROTECTIVE VEHICLE (WORK VEHICLE) = R NO SPECIFIED DISTANCE REQUIRED IMPORTANT NOTICE Section # 4216/4217 of the Government Code requires a Dig Alert Identification Number to be issued before a "Permit to Excavate" will be valid For your Dig Alert I.D. CALL TOLL FREE 48 HOURS BEFORE YOU DIG UNDERGROUND SERVICE ALERT 1-800-227-2600 CHANNELIZATION DEVICE SPACING (feet) MPH TAPER TANGENT 35/40 30 60 25/30 20 40 50' NOTES ZZOZ/ 11/90 1. DEVICE SPACING FOR THE DOWNSTREAM TAPER SHALL B ' F 2. ALL SIGNS ARE BLACK ON ORANGEQ310N SV GDA021dd`d NOISIAId ON12J33NIJN3 #<ESH�- SCALE: N.T.S 802 DRjFff_QQ0I,JgWh98020 TpkA**kdk- PROJ#: JB994769 CONSTRUCTION TYPE: MAINTENANCE SPLICE SYSTEM: EDMONDS EMAIL: ERIC.MCDOWELL@CABLECOMa J U L 11 2022 TC-2 SHEET: 2 OF 7 BUFFER DATA LONGITUDINAL BUFFER SPACE = B SPEED (MPH) 25 30 35 40 45 50 55 60 65 70 LENGTH (feet) 155 200 250 305 360 425 495 570 645 730 TRANSPORTABLE ATTENUATOR ROLL AHEAD DISTANCE = R HOST VEHICLE WEIGHT 9,900 TO 22,000 Ibs. HOST VEHICLE WEIGHT > 22,000 Ibs. < 45 MPH 45-55 MPH > 55 MPH < 45 MPH 45-55 MPH > 55 MPH 100' 123' 172' 74' 100' 150' PROTECTIVE VEHICLE (WORK VEHICLE) = R NO SPECIFIED DISTANCE REQUIRED DRIFTWOOD LN 25 MPH a a X 4 ONE LANE ROAD AHEAD 4 48" W20-4 ROAD WORK AHEAD 48" W20-1 LEGEND FLAGGING STATION a TEMPORARY SIGN LOCATION CHANNELIZING DEVICES PROTECTIVE VEHICLE X X X I 50' TO 300' " . • 48" BE \ PREPARED \TO STOP/r W20-7B W20-71B (OPTIONAL IF 40 MPH OR LESS) THIS IS A COMCAST DOCUMENT, PROPRIETARY & CONFIDENTIAL REV DESCRIPTION DATE DESIGN: 0 ISSUE FOR PERMIT 7/6/2022 DRAWN BY: ERIC APPROVED: APPROVED: APPROVED: W20-7A SIGN SPACING = X (1) RURAL HIGHWAYS 60 / 65 MPH 800' +/- RURAL ROADS 45 / 55 MPH 500' +/- RURAL ROADS & URBAN ARTERIALS 35 / 40 MPH 350' +/- RURAL ROADS, URBAN ARTERIALS, RESIDENTIAL & BUSINESS DISTRICTS 25 / 30 MPH 200' +/- (2) URBAN STREETS 25 MPH OR LESS 100' +/- (2) (1) ALL SPACING MAYBE ADJUSTED TO ACCOMMODATE INTERSECTIONS AND DRIVEWAYS. (2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS. 50' TO 100' 6 DEVICE MIN AREA 50' TO 100' 6 DEVICE B MIN. W20-713 (OPTIONAL IF 40 MPH OR LESS) 48" 48" BE ROAD PREPARED WORK TO STOP HEAD 48" 48" 48" 48" . W20-713 ONE LANE W20-1 ROAD AHEAD 48" 48" W20-7A W20-4 X i X X i X X 48„ SzLO • JN X 48" 48" a BE NNN W20-7A Q y PREPARED 40 MPH (OPTIONAL IF Q 40 MPH OR LESS) 0 TO STOP X 48" 48„ H IL ONE LANE W20-7B y ROAD � AHEAD X 48" 48" W20-4 ROAD CHANNELIZATION DEVICE SPACING (FEET) MPH TAPER TANGENT 50/65 10 TO 20 80 35/45 10 TO 20 60 25/30 10 TO 20 40 4 WORK NOTES HEAD 48" 1. ALL SIGNS ARE BLACK ON ORANGE. W20-1 2. EXTENDING THE CHANNELIZING DEVICE TAPER ACROSS ONE -LANE, TWO-WAY TRAFFIC CONTROL WITH FLAGGERS NOT TO SCALE IMPORTANT NOTICE Section # 4216/4217 of the Government Code requires a Dig Alert Identification Number to be issued before a "Permit to Excavate" will be valid For your Dig Alert I.D. CALL TOLL FREE 48 HOURS BEFORE YOU DIG UNDERGROUND SERVICE ALERT 1-800-227-2600 SHOULDER IS RECOMMENDED. 3. NIGHT WORK REQUIRES ADDITIONAL ROADWAY LIGHTING AT FLAGGING STATIONS. SEE THE STANDARD SPECIFICATIONS FOR ADDITIONAL DETAILS. 4. SEE SPECIAL PROVISIONS FOR WORK HOUR RESTRICTIONS. 802 DRjFffMj)@i0rggWR98020 TpkA**ktb- PROJ#: JB994769 CONSTRUCTION TYPE: MAINTENANCE SPLICE SYSTEM: EDMONDS EMAIL: ERIC.MCDOWELL@CABLECOMa i@T�_ SCALE: N.T.S J U L 11 2022 TC-1 SHEET: 1 OF SIGN SPACING = X (1) RURAL ROADS & URBAN ARTERIALS 35 / 40 MPH 350' +/- RURAL ROADS, URBAN ARTERIALS, 25 / 30 MPH 200' +/- (2) RESIDENTIAL & BUSINESS DISTRICTS URBAN STREETS 25 MPH OR LESS 100' +/- (2) (1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERSECTIONS AND DRIVEWAYS. (2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS. LEGEND a TEMPORARY SIGN LOCATION CHANNELIZING DEVICES PROTECTIVE VEHICLE MINIMUM SHOULDER TAPER LENGTH = L/3 (feet) SHOULDER Posted Speed (mph) WIDTH (feet) 25 30 35 40 45 50 55 60 65 70 8' 40 40 60 90 - - - - - - 10' 40 60 90 90 USE A 3 DEVICES TAPER FOR SHOULDERS LESS THEN 8' MELODY LN 25 MPH X X L/3 B"I 48" 48" ROAD SHOULDER WORK WORK HEAD 48" 48" W20-1 XA/91 _F THIS IS A COMCAST DOCUMENT, PROPRIETARY & CONFIDENTIAL REV DESCRIPTION DATE DESIGN: 0 ISSUE FOR PERMIT 7/6/2022 DRAWN BY: ERIC APPROVED: APPROVED: APPROVED: SHOULDER CLOSURE — LOW SPEED (40 MPH OR LESS) NOT TO SCALE IMPORTANT NOTICE BUFFER DATA LONGITUDINAL BUFFER SPACE = B SPEED (MPH) 25 30 35 40 45 50 55 60 65 70 LENGTH (feet) 155 200 250 305 360 425 495 570 645 730 TRANSPORTABLE ATTENUATOR ROLL AHEAD DISTANCE = R HOST VEHICLE WEIGHT 9,900 TO 22,000 Ibs. HOST VEHICLE WEIGHT > 22,000 Ibs. < 45 MPH 45-55 MPH > 55 MPH < 45 MPH 45-55 MPH > 55 MPH 100' 123' 172' 74' 100' 150, PROTECTIVE VEHICLE (WORK VEHICLE) = R NO SPECIFIED DISTANCE REQUIRED Section # 4216/4217 of the Government Code requires a Dig Alert Identification Number to be issued before a "Permit to Excavate" will be valid For your Dig Alert I.D. CALL TOLL FREE 48 HOURS BEFORE YOU DIG UNDERGROUND SERVICE ALERT 1-800-227-2600 CHANNELIZATION DEVICE SPACING (feet) MPH TAPER TANGENT 35/40 30 60 25/30 20 40 50' NOTES 1. DEVICE SPACING FOR THE DOWNSTREAM TAPER SHALL BE 20' (FT). 2. ALL SIGNS ARE BLACK ON ORANGE. -W SCALE: N.T.S J U L 11 2022 802 DRjFffj)Q0I,JgWh98020 TpkA**ktb- PROJ#: JB994769 CONSTRUCTION TYPE: MAINTENANCE SPLICE T`�-4 SYSTEM: EDMONDS l EMAIL: ERIC.MCDOWELL@CABLECOML SHEET: 4 OF 7 SIGN SPACING = X (1) RURAL ROADS & URBAN ARTERIALS 35 / 40 MPH 350' +/- RURAL ROADS, URBAN ARTERIALS, 25 / 30 MPH 200' +/- (2) RESIDENTIAL & BUSINESS DISTRICTS URBAN STREETS 25 MPH OR LESS 100' +/- (2) (1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERSECTIONS AND DRIVEWAYS. (2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS. LEGEND a TEMPORARY SIGN LOCATION CHANNELIZING DEVICES PROTECTIVE VEHICLE MINIMUM SHOULDER TAPER LENGTH = L/3 (feet) SHOULDER Posted Speed (mph) WIDTH (feet) 25 30 35 40 45 50 55 60 65 70 8' 40 40 60 90 - - - - - - 10' 40 60 90 90 USE A 3 DEVICES TAPER FOR SHOULDERS LESS THEN 8' HINDLEY LN 25 MPH a a X 48" 48" ROAD <HOULDER WORK RK AHEAD 48" 48" W20-1 W21-5 THIS IS A COMCAST DOCUMENT, PROPRIETARY & CONFIDENTIAL REV DESCRIPTION DATE DESIGN: 0 ISSUE FOR PERMIT 7/6/2022 DRAWN BY: ERIC APPROVED: APPROVED: APPROVED: BUFFER DATA LONGITUDINAL BUFFER SPACE = B SPEED (MPH) 25 30 35 40 45 50 55 60 65 70 LENGTH (feet) 155 200 250 305 360 425 495 570 645 730 TRANSPORTABLE ATTENUATOR ROLL AHEAD DISTANCE = R HOST VEHICLE WEIGHT 9,900 TO 22,000 Ibs. HOST VEHICLE WEIGHT > 22,000 Ibs. < 45 MPH 45-55 MPH > 55 MPH < 45 MPH 45-55 MPH > 55 MPH 100' 123' 172' 74' 100' 150, PROTECTIVE VEHICLE (WORK VEHICLE) = R NO SPECIFIED DISTANCE REQUIRED z o Z-11110- (V X L/3 B"I 50' SHOULDER CLOSURE — LOW SPEED (40 MPH OR LESS) NOT TO SCALE IMPORTANT NOTICE Section # 4216/4217 of the Government Code requires a Dig Alert Identification Number to be issued before a "Permit to Excavate" will be valid For your Dig Alert I.D. CALL TOLL FREE 48 HOURS BEFORE YOU DIG UNDERGROUND SERVICE ALERT 1-800-227-2600 CHANNELIZATION DEVICE SPACING (feet) MPH TAPER TANGENT 35/40 30 1 60 25/30 20 1 40 NOTES 1. DEVICE SPACING FOR THE DOWNSTREAM TAPER SHALL BE 20' (FT). 2. ALL SIGNS ARE BLACK ON ORANGE. SCALE: N.T.S J U L 11 2022 802 DRjFff_QQ0I,JgWh98020 TpkA**kdk- PROJ#: JB994769 CONSTRUCTION TYPE: MAINTENANCE SPLICE Tr_S SYSTEM: EDMONDS l J EMAIL: ERIC.MCDOWELL@CABLECOML SHEET: 5 OF 7 SIGN SPACING = X (1) RURAL ROADS & URBAN ARTERIALS 35 / 40 MPH 350' +/- RURAL ROADS, URBAN ARTERIALS, 25 / 30 MPH 200' +/- (2) RESIDENTIAL & BUSINESS DISTRICTS URBAN STREETS 25 MPH OR LESS 100' +/- (2) (1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERSECTIONS AND DRIVEWAYS. (2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS. LEGEND a TEMPORARY SIGN LOCATION CHANNELIZING DEVICES PROTECTIVE VEHICLE MINIMUM SHOULDER TAPER LENGTH = L/3 (feet) SHOULDER Posted Speed (mph) WIDTH (feet) 25 30 35 40 45 50 55 60 65 70 8' 40 40 60 90 - - - - - - 10' 40 60 1 90 90 USE A 3 DEVICES TAPER FOR SHOULDERS LESS THEN 8' BROOKMERE ST 25 MPH X X L/3 B"I 48" 48" ROAD SHOULDER WORK WORK HEAD 48" 48" W20-1 XA/91 _F THIS IS A COMCAST DOCUMENT, PROPRIETARY & CONFIDENTIAL REV DESCRIPTION DATE DESIGN: 0 ISSUE FOR PERMIT 7/6/2022 DRAWN BY: ERIC APPROVED: APPROVED: APPROVED: SHOULDER CLOSURE — LOW SPEED (40 MPH OR LESS) NOT TO SCALE IMPORTANT NOTICE BUFFER DATA LONGITUDINAL BUFFER SPACE = B SPEED (MPH) 25 30 35 40 45 50 55 60 65 70 LENGTH (feet) 155 200 250 305 360 425 495 570 645 730 TRANSPORTABLE ATTENUATOR ROLL AHEAD DISTANCE = R HOST VEHICLE WEIGHT 9,900 TO 22,000 Ibs. HOST VEHICLE WEIGHT > 22,000 Ibs. < 45 MPH 45-55 MPH > 55 MPH < 45 MPH 45-55 MPH > 55 MPH 100' 123' 172' 74' 100' 150, PROTECTIVE VEHICLE (WORK VEHICLE) = R NO SPECIFIED DISTANCE REQUIRED Section # 4216/4217 of the Government Code requires a Dig Alert Identification Number to be issued before a "Permit to Excavate" will be valid For your Dig Alert I.D. CALL TOLL FREE 48 HOURS BEFORE YOU DIG UNDERGROUND SERVICE ALERT 1-800-227-2600 CHANNELIZATION DEVICE SPACING (feet) MPH TAPER TANGENT 35/40 30 1 60 25/30 20 1 40 50' NOTES 1. DEVICE SPACING FOR THE DOWNSTREAM TAPER SHALL BE 20' (FT). 2. ALL SIGNS ARE BLACK ON ORANGE. SCALE: N.T.S J U L 11 2022 802 DRjFff_QQ0I,JgWh98020 TpkA**kdk- PROJ#: JB994769 CONSTRUCTION TYPE: MAINTENANCE SPLICE TC— 7 SYSTEM: EDMONDS EMAIL: ERIC.MCDOWELL@CABLECOML SHEET: 7 OF 7 RECEIVED J U L 11 2022 CITY OF EDMONDS CITY OF EDMONDS MyBuildingPermit.com DEVELOPMENT SERVICES DEPARTMENT Right-Of-wav prrliration #1170485 - COMCAST - JB0000994769 - EDMONDS 1 Applicant First Name Last Name Company Name OWEN SHACKEET COMCAST Number Street Apartment or Suite Number E-mail Address 410 VALLEY AVE NW OWEN SHACKETT@CABLE.COMCAST. City State Zip Phone Number Extension PUYALLUP WA 98371 (253) 341-9318 Contractor Company Name Cablecom LLC Number Street Apartment or Suite Number 19910 NORTH CREEK PARKWAY NORTH 100 City State Zip Phone Number Extension BOTHELL WA 98011 (360) 863-2628 (360) 454-3163 State License Number License Expiration Date UBI # E-mail Address CABLEL*971 DP 8/21/2023 FD99RSS79 SNOHOMISH.PERM ITTING@CABLECO Project Location Number Street Floor Number Suite or Room Number 802 DRIFTWOOD LN City Zip Code County Parcel Number EDMONDS 98020 27031300303700 Associated Building Permit Number Tenant Name Additional Information (i.e. equipment location or special instructions)_ Work Location Property Owner First Name Last Name or Company Name William R Jr Volpentest Number Street Apartment or Suite Number PO BOX 77568 City State Zip SEATTLE WA 98177 Certification Statement - The applicant states: I certify that I am the owner of this property or the owner's authorized agent. If acting as an authorized agent, I further certify that I have full power and authority to file this application and to perform, on behalf of the owner, all acts required to enable the jurisdiction to process and review such application. I have furnished true and correct information. I will comply with all provisions of law and ordinance governing this type of application. If the scope of work requires a licensed contractor to perform the work, the information will be provided prior to permit issuance. Date Submitted: 7/8/2022 Submitted By: OWEN SHACKEET Page 1 of 2 i CITY OF EDMONDS MyBuildingPermit.com Right -of -Way Application #1170485 - COMCAST - JB0000994769 - EDMONDS 1 Project Contact Company CABLECOM LLC Name: Name: SUNSHINE CRABBS Email: SUNSHINE.CRABBS@CABLECOMLLC.NET Address: 19910 NORTHCREEK Phone (360) 454-3163 PARKWAY N, 100 #: BOTHELL WA 98011 Project Type Activity Type Scope of Work Utility Purveyor Utility Work No Disturbance of Surface Project Name: COMCAST - JB0000994769 - EDMONDS 1 MAINTENANCE SPLICES AT EXISTING AERIAL AND GROUND CASES AT THE Description of FOLLOWING 9 LOCATIONS, 802 DRIFTWOOD LN 1402 9TH AVE N 1400 9TH AVE N 800 Work: PUGET LN 742 MELODY LN 815 HINDLEY LN 906 PUGET WAY 902 HINDLEY LN 915 BROOKMERE ST NO NEW CONSTRUCTIONS IN ALL EXISTING CASES. Project Details Project Information Job Number JB0000994769 Page 2 of 2