Loading...
1190996_Manufacturer_Specifications_and_Installation_Instructions_08-22-2022_07_19_28_Spec Sheets- Komorita1❑ 2❑ ❑5 ELECTRIC SHOCK HAZARD TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION LABEL LOCATION: POINT OF INTERCONNECTION, MAIN SERVICE DISCONNECT, AC DISCONNECT, AC COMBINER, INVERTER PER CODE: NEC 690.13(B) ACAUTION DUAL POWER SOURCE SECOND SOURCE IS IftPHOTOVOLTAIC ■ I ARFI I OCATION- MAIN SERVICE DISCONNECT/ AC DISCONNECT/ MAN SERVCE PANEL/ REVENUE METER/ AC COMBINER PER CODE: NEC 705.12(C) 3 CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED LABEL LOCATION: 8 POINT OF INTERCONNECTION & INVERTER PER CODE: NEC 690.15 & 690.13(B) u SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE 'OFF' POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY NAM K!C•K @*I rNRts LABEL LOCATION: MAIN SERVICE DISCONNECT IF MSD IS OUTSIDE PLACE IT THERE / IF MSD IS INSIDE PLACE ON THE AC DISCONNECT PER CODE: 2020 NEC 690.56(C) LABEL LOCATION: AC DISCONNECT PER CODE: NEC 690.56(C)(2) LABEL LOCATION: INTERACTIVE SYSTEM POINT OF INTERCONNECTION PER CODE: NFPA 70. NEC 690.54 WARNING INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE LABEL LOCATION: PLACE THIS LABEL AT P.O.C. TO SERVICE DISTRIBUTION EQUIPMENT (I.E. MAIN PANEL (AND SUBPANEL IF APPLICABLE)) PER CODE: NEC 705.12(B)(3)(2) LABEL LOCATION: CONDUIT PER CODE: NEC 690.31(D)(2) CAUTION: SOLAR CIRCUIT LABEL LOCATION: MARKINGS PLACED ON ALL INTERIOR AND EXTERIOR CONDUIT, RACEWAYS, ENCLOSURES, AND CABLE ASSEMBLIES AT LEAST EVERY 10 FT, AT TURNS AND ABOVE/BELOW PENETRATIONS AND ALL COMBINER/JUNCTION BOXES PER CODE: IFC 606.11.1.4 LABEL LOCATION: INVERTER & JUNCTION BOXES (ROOF) PER CODE: NEC 690.13 (G)(3) & 690.13 (G)(4) Lumio SMART ENERGY TODAY (SET) 1550 DIGITAL DR, LEHI, UT 84043, USA SYSTEM INFO (12) Q CELLS Q.PEAK DUO BLK ML-G10+ (400W ) (12) ENPHASE IQ8PLUS-72-2-US (240V) DC SYSTEM SIZE: 4.80 kWDC AC SYSTEM SIZE: 3.60 kWAC REVISIONS DESCRIPTION I DATE I REV PROJECT NAME & ADDRESS w O 0 Z LL, O Y 0 Z w 2 W O a U) Z) O N O co 0 Z 2 0 W J d F- CG C) 0) N N It N 0 0 0 NT 0 0 00 c0 LC) O O Z d im DATE:8/13/2022 1 SHEET NAME SIGNAGE ADHESIVE FASTENED SIGNS SHEET SIZE • THE LABEL SHALL BE SUITABLE FOR THE ENVIRONMENT WHERE IT IS INSTALLED. ANSI B • WHERE REQUIRED ELSEWHERE IN THIS CODE, ALL 11" X 17" FIELD APPLIED LABELS, WARNING AND MARKINGS SHOULD COMPLY WITH ANSI 2535.4 [NEC 110.21(B) FIELD MARKING]. SHEET NUMBER • ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF PV-9 PROPERLY ADHERED. VINYL SIGNS SHALL BE WEATHER RESISTANT [IFC 605.11.1.3] LABEL LOCATION: EACH SERVICE EQUIPMENT LOCATION AND AT THE LOCATION(S) OF THE SYSTEM DISCONNECT(S) FOR ALL ELECTRIC POWER PRODUCTION SOURCES CAPABLE OF BEING INTERCONNECTED (PER CODE: NEC 705.10) Lumio SMART ENERGY TODAY (SET) 1550 DIGITAL DR, LEHI, UT 84043, USA SYSTEM INFO (12) Q CELLS Q.PEAK DUO BLK ML-G10+ (400W ) (12) ENPHASE IQ8PLUS-72-2-US (240V) DC SYSTEM SIZE: 4.80 kWDC AC SYSTEM SIZE: 3.60 kWAC REVISIONS DESCRIPTION I DATE I REV PROJECT NAME & ADDRESS a U) 0 N O co O) a C) O � a ~ NT W o O O Zz rn O O C4 C)Lo w LLI z o O � a z o_ = a F- 0 0) N N N DATE: 8/13/2022 SHEET NAME SIGNAGE SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-10 MECHANICAL SPECIFICATION � - DUO — fonrlal Alon.ulna376nry+CWf�Ottlrnp ---....... _............. .... _..... 1i67P+ena14r4rK+a32a7T/ r.fer�r-......... :..•uaslmx rfe1N Lew D.t3.t ().iAfr'� IIMwIY afe�4fwr0 p1� 1a11i1t-• I ,.ri rr'• :I II I i a11)-YftfRart led nWaft r .: I r,•rmr•r•rr• r 'I f, MCLCeMr COrrOOW!61 it !I IIw='a1a.'r�c hsfr• IlufrrarorSasO wvsry :I j " C<rf 8 x 222 ma.^.axystaGne^ A'v1 L FL sofa: i agl ce45 ....... _....... _.............. ............................ ....................... _....... .................. _..�,.. s 7 II i Ju+ctbn b• ? U9-3 921rr. x ].`LE-i. +0^8•: • O.:i9-0.7i'v! S j II - li (53-101m1ix32-6Gmrlx_35-1...... 8mr:j,IP87,withCyp..53d;oGes CtlM4mTR......i..r....................................................................................{' ......................................... .. .... f; I .._•---0 •.s�..w..w i i .2in(?.250mr.),(-)a49.2ini!25�7.rml .._........................li ......... s . Coafrcw Bts Ail F.<C4; I'r6a sl ••wroaa• ;I amm.s. a I IMPMw . • : , ELECTRICAL CHARACTERISTICS POrAKR CLALs an m m 400 do M NNLM N Rt 09MANCE AT STANDARD TEST CONplTIOAS. STC :+OWFR T0jRANCE •6 W; -0 WI Pgwat of mw. Pw, I'.w; 356 300 386 400 405 _............. ............... 6laprf Cs tvf C•rrant• 1, (Al 1-1.04 _L07 »SO LLi4 ii17 �. 5jp ( o OW�C+rwrWeapaa Vat (v) 45_i9 __ <623 4527 46.30 ... s ......_.._ 7 C.f.•.f n MPP rw. ldl ..._... ..._...... .... . / ?0.59 a0oi 3073 30.77 ±Cr.E:i V0ra3eweMP Vm•. jV; ...-3i%:i6 3662 3600 3713 5:.39 -- .._.._.._........_........_. ....__.._..__.._.._...._............................................................ EMc+`cY• 6 04 Rios a19.9 _'7�'11'.................................'Yi6 ..... ...._--- MFWALo M KWOWAANCt AT NOWAAL OptRAT11V6 CONW PDNS- NMOTr ............ . 0 CtLLS-------------...................... -- ........... ............^_... Warranty Pew. of wo ►_ MA 2166 2 _ 92.e ...................291:.3 3004 30a.8 _......................................................... fad •..--a.- fadS• rf Sfgtf CIKJI CWrW* 1, W 660 06.92 B9s 6.n7 0.00 _.._........................................................_.._............................. 0M.. t Op-1VOtepa V« M 4262 42.BE• ^...................»2:Sy 42.72 42.76 ......................_........._..... _................................ .... .... _.._.._._.._..._..._._... BREAKING T14E20%E►FICIENCYBARRIER 2 cArfwltatNPP a41 S46 8-5i 3.57 C ANTUM OW Z Tocrrdogy v0vn mo pep OM WioLn wferpe w w" V_ WI 3460 3463 3603 36.25 364 �+++� Dowtsm *Aoattoorncyupto20.9%. wwwwtti+►.tiwP.-Is4k .V-: 16%estc 20WAwe.2birC.Au:bo=wd�)uEC*OX&I-1e0YAv--.%4,* woce "Aalia O CELLS MRf OPMANCC WARRANTY ff RfOCMANC r AT LOW IRRADIANCC THE IDEAL SOLUTION FOR: Engineered in Germany TIDE MOST THOROUGH TESTING PROGRAMME IN THE INDUSTRY I 0 CELLS Is I* f V9 SCW moo se M*nJWkM 10 pees re mW oompmhon • Q %ha gl►Nty wgrarme n His i d-gvy The now'Quality Contros:ed PV' of v� me IMopor4ore cerr ration nsm...ra I W RlwrUn'Id. INNOVATIVE ALL-WEATHER TECHNOI COY Opt" yolds wt►toww Vo we~ wars oxwent IOrw _iv. an i 10rT W rA" botwA f (NDURn.G /uGlf PtQL0R%1ANCL Long-Wrn yield Soo^ *Ath Anti LID Toclrgbgy, Anti PIQ ' Todv+ ftW. HOC -Spot Prewl and TrocwM Ouolity Tra.Q m. EXTREME WEATHER RATING 1f10h-lied+ Ourk m 4ADy frame. owtr. ad ICf ►ph of *w (5400 Pe) and ws d both 44000 Pep A PELtABLE t4VESTMENT hclxvo 25 war Product warranly and 25-Year Atil fr t}+%vrr4wce warranivl. APT No owdecm eoowmV a KC)ITS 02SO4 _:2035, mAlnoo A{-= ;1•JV. 9cni ' Sar Ores n�1 on rN b bf+' r+bmn:::r. Q CELLS i� pm Ir l r kilib • • r • r r .sass A. bet Sf)Ta.0- OOWpd"v fm,w -w"pw no 01't ovDo" ow ~ N W" OS Dz ur�rvrlP&ww.Ow10pan Af ...• 1»• N+r•.« P7wer . N :7 r+fa Al Osfa wren m44 t w'wf gUKrlfi S1A fftmm wT4c1 t*Q( .A w" of rw v1pelwe CeLr" mt i w rra.•r•cr •.✓ iiscd TOAD• ow%yrw' a w do low hgr+a comobwe an c4ffvw4Cr s) STC O"SorA OL'C. LOCO %%VVI T1f•fwwwo COafllcwrl d lrr: P IKIKI •0.04 TefapwwwgCOam41N1efv. I IIsnl -Or Tafrpwatarr Co*"1cwv1of P.m. 4 ISIKJ -034 Neft.W MoOW Opom" Ywrrwo— MOOT t'rl 109iBA(43s3'C) PROPERTIES FOR SYSTEM DESIGN 4182Nrem3)we VeflopeV_ m L00o(11011000NU IwNoescs"anc.son ..........................Cloys 1. Noa)nun sort" Paee RMhO 1A DC) 30 Pali ft0ho lr @den A11411 LIL 43 730 ......----................. h'?E 2... lAasLOewOnlorf/prafl/hq i�►H 7ipi00PL#J66Q400pe1 PwrnYbdsf00ADriffpetwwo 47`.6pu.•85•c &M&Tom Lomi,P)an/PW POW"I 11304OWWWWOWN onconMuow01AY I-44'Cto1*.66'CI QUALIFICATIONS AND CERTIFICATES :LC 7:•:..i;.rca:y:.v¢. Cav1L:•r:�ctt:ri:rro'r.'-'i tiV trnr::::a:::s. C. c c E .r�.GL•l:ir`i.`i47:S.ii la:::p. PACKAGING INFORMATION Mw�oeMM 764n 433n 460n 146Id 24 24 $2 r»obwy mo+rlm 1100wn 32]Own 76tr0 Pwu ww m*dAm NOf•: Inblei:d:iOr iaS.nxri;.n) :r:qg! be rzAoA.eO. See ifE b)watiF.-lam•! d: W C.'.1@rcliPO IPBPJdb a COn:f.^.i :'r. is igra:! CHi swvice OG'Abi :r:,2fA iOr wribe., irb�:obri::n pr• �pl:r.. '83:r!Srdai:kr�: ar:�; l:>r' Oi lianwlla Cf CSLLSAmorlc■Inc. d:Q'•Slxetruu:.:ran:wi iiRee, fi:i O!rC,v, iivi�.e. C:, ro3n..GAi TEL-. DOMBtY961 CAA&LrOAPO AACt .Q" rI WIA Ww.1,=0:5:.3 Lumio UNION SMART ENERGY TODAY (SET) 1550 DIGITAL DR, LEHI, UT 84043, USA SYSTEM INFO (12) Q CELLS Q.PEAK DUO BLK ML-G10+ (400W ) (12) ENPHASE IQ8PLUS-72-2-US (240V) DC SYSTEM SIZE: 4.80 kWDC AC SYSTEM SIZE: 3.60 kWAC REVISIONS DESCRIPTION I DATE I REV PROJECT NAME & ADDRESS a 07 Z) O N O c0 Q O O ~ �' NT W o O ZZ rn O C) C4 Lo Z w WC) O d Z F- a (O O r- 0) N N N DATE: 8/13/2022 SHEET NAME EQUIPMENT SPECIFICATIONS SHEET SIZE ANSI B 1111 X 17" SHEET NUMBER PV-11 ENPHASE IQ8 and IQ8+ Microinverters Our novypst 1081Atcrorrverters arc the ndustry•s fir3t m Crogrid-formet%eDftware- defined micrornrerters with split -phase power conversion capatAtty to Convert DC power to AC power efftciemly. The train of the semiconductor -based micrarn•efter is otr proprietary application• spobhr- integrated clrcut (ASIC) which enables the miCroinrrerter to operate in g• d-Sed or oM- grid modes. This chip is twit in advanced 55r1m tochnolpgy with high speed dsgtal Icgic and has super -fast response times to changing loads and grid events. al*viMing constraints on battery sizing for home energy systems. t . j M d tfe t•p•sw t'efO/ 51rMwn lee s« w aactt!•'IA•ta-a rr>♦p•ala vets, the lrtphase'O Sattry, E rrCM w W W rave a� and t►t" Erprrrr Appnrcr.to.q ar.7 a•alrtrs schowe. Coved 0-1 nodAn Cucafr and wars, to *6 swiss 1Ncrorwwtrs wM the twuded 04)CC•2 adarcw cahls oath rrt►r2-n Olar WCt cenrectWIL 101 Sw.oa Mcromee ws rodaAre raaabday Ito -dams Mth "ore than rf71w •sae+ c.rroatrr" hours of pmw o-sntr.y rant-g an ndssl•y rodrV a+rted wwrarty of tp to 23 ►vet• s. 102 Sw eis 064cronr"rtws are UI. lalod n Ptak Rapd ?rh Down lgJpryw-1 a-d ocher, m .►+� va•.xe raq�la^_o•s-rr+wr nsraw amccts p l0 rne-utsct.rwl nat•uct4m o 2021 Fn.ttas" Frw9v At r9td mwvwd Fr• mo, the E rplsaw fogo,101 nscrurrw tw1 a•d Drw rssssea a•e r4deiruirlis d trdw tnwpr, he Data VA 00t to char-" 1011WDs 0002-01 EN us : l 10 19 ® IQ8 and IQ8+ Microinverters Easy to lnstatl • LgMwtrgtrt and compact with plug-n-p4av connectors • Poww line Communcaton (PLC) between components F=w nstallatlon with srnplo two -wire Cabing Figh productivity and reliability • Produce power man wt•on ma grid is down Wre than one million currlflatrve hours of testing • Class II doubla-insulated enclosure • Optimized for the latest high- powered PV modfles Aicrogrld-forming Compies with the Latest advanced grid support Remote automatic updates for the latest grid repuiromenis Configurable to sluppW a wide range of grid p(oHes Maets CA Rule 21(Ul 1741-SA) requirements Ccrrrro•tr u.ad n»dis panrgi .. 230 - mo 235 - 440 sAudJ" co+pr�Uttr 40•tet/120 Pear -cal M<eE/120 hall,ceh amid 72-caE/YA NO -tea WM volts" rare 72 - 37 » - 45 owarl"9 nary" 23 - K 23 - 34 kuv"%"ttrtVol-Age r 30/44 30/54 Waa upsR DC .atspo r 30 60 M"oc rwrt'IMOAAWWI a 15 oswvoluae class DC port 0 DC port barlb"d cswrww oar O Pv wrar cnrApj, ton 41 Il+erourdad sear: go adlrrr M DC We Voleethon regAled AC aNa prolKtbn r"q•aras rra. 20A par "-Co%cr ,n Peak c4ju ul power ss 300 stag co•tatuu dutpA paww It 290 h "rri 0,-0 sotagatrar901 r 240/ 2I1- 264 Miaxevts+w.n o -pil c-rake•# a 121 hl-1 freprwxy w 60 Ener.ded rreammv rave w SO - 66 Wax Wta per 20 A Q-Ll branch tacit 13 Taal trnnaK 4swoROn <Sla Oswvdtae" clam AC pert ■ Ac port hactteed care".. Y 30 Nouw lector wart- 1.0 Oral -sod paww far" taQurratM) OAS toadnq - O s3 Hgv q Peak elk-erx/ ♦ 97.3 97.6 CtC *09-ted.Ac"MV 1 91 97 Nlght-Ors" poww oorrsrsprxn .« 60 Anbom Ernpralas nnq" -e0ce to •409C (-eo'f to •LOcf) e"art%o-.sndtyrarq" 4%to 1001c Gcon Arq) DC Corrector erne Mice orrerwfore Ot.wxw 2t2 mm (4.3.) s 175 "" OW) x 302 mm (tr) wev et we ►p (2 34 b) cc•K"0 Naoral wfivocem - ao tan Approved for wM Imaborst yr• Acowk no w if. 1 m •00 49A Pot~ dow" PD3 r rxsz. " Casa p do.6fi-4rieJatW. corroron rwaatan po/ttreric wxsou" Erwroo cal*W p / VV espoeue mwq Nee two a / o.Adoa CA sue 21 WIL 1)W -sail Ut e21DO-1. UU WK1111547. / CC r1r1 /5 G1na a. ICII3 0003 0", a, GAMIC SA-C22.2110 101101 Carsflawi3f a IN* rra3.ct b UL l4%d as PV fund YJ Do r Eputrro 4 •-d axhrr roar -th NEC 20te. NEC 2011. road NEC 2WO *d0k7n 00092 and C22.1.2011111164-21f Aapd S•utd-vxr• of Pv nor X rd DC oondxtat, rsNrt nstatad accord►- to elwsatKbrv's nyttuctrom (0 No errbroed DC/AC rrlo 3"e the 0urparR4Ry oModttor at MtpaN{re.NWewtcm/ n1d.M <o.tprRrttr (2) Wa on.n owwnw.a "A DC osnwrt a %a" (3) Weft al Ketage %nq" car• be a.lw+dW b"ord rurtaul'r?"A"by W* r,"Wfk le) k Wa$ r►ay .wy. ft" to focal rea wwrewh to deft the rusber d ink rorwwtsn par trench my" area tObsP 06 0002-01-fN its 20Qt •t0 K Lumio SMART ENERGY TODAY (SET) 1550 DIGITAL DR, LEHI, UT 84043, USA SYSTEM INFO (12) Q CELLS Q.PEAK DUO BLK ML-G10+ (400W ) (12) ENPHASE IQ8PLUS-72-2-US (240V) DC SYSTEM SIZE: 4.80 kWDC AC SYSTEM SIZE: 3.60 kWAC REVISIONS DESCRIPTION I DATE I REV PROJECT NAME & ADDRESS v/lal^^ Z) O N O 00 rn Q O O Q � ~ NT W C) O O Zz rn O O p to Z LU LLI O O . d z D_ = a F— (O O N N N DATE: 8/13/2022 SHEET NAME EQUIPMENT SPECIFICATIONS SHEET SIZE ANSI B 1111 X 17" SHEET NUMBER PV-12 Less Aluminum V4more Efficient Design Additional Mounting Options Metal, EPDM, TPO, & Asphalt Roofs Instaiiation ivianual cc �S ICC ESR 3575 _ _.tom RT-MINI II is suitable for all systems with a conventional L-Foot. 1/4" x 1" Carriage Bolt EMT \\ Accessory RT Serrated Hex Flange Bolt/Nut: 5/16-18 x 1 " Components _ 46&. RT2-00-MINIBK2 Ab6 MINI II base 20 ea Screw 40 ea Extra RT-Butyl 5 ea. Optional Items: 5 x 60tTIM Mounting Screw IRT2-04-S05-60) 100 ea.,Sag 5.116 X 251,1&1 Flange Bolt & Nut (RT2.04-FBN25) . 100 ea)Bag RT-Butyl (RT2.044A48UTYL) 10 ea.IBox Deck Installation Rafter Installation RT-Butyl is Roof Tech as flexible flashing used in one million res4ertOd PV systems for the bast 27 years. It is the first PV mour-4ng system with Flexible Flashing certified by the ICC. Englreered to wlnstand nlnd speeds up to 180 mph and grand snow up oo 90 pst. Engineered to ASTM D 1761 (Srandard Test Methods for Median" Fas*ners in'tVoWl ICC ESR-3575 ASTM2140 Testing ...-0 root P.E SkrrryrC LeVers ivii6sule a; www.roof-tech.us�support ti Dimensions in (mm) 3 54 Inch (90rrrn) 60 WICA (15.4mm) Offset Rafter Installation Tt Offset Rafter Attachment Options 1 Metal Flashing Retrofit Flexible Flashing h' 100% Waterproof Lumio SMART ENERGY TODAY (SET) 1550 DIGITAL DR, LEHI, UT 84043, USA SYSTEM INFO (12) Q CELLS Q.PEAK DUO BLK ML-G10+ (400W ) (12) ENPHASE IQ8PLUS-72-2-US (240V) DC SYSTEM SIZE: 4.80 kWDC AC SYSTEM SIZE: 3.60 kWAC REVISIONS DESCRIPTION I DATE I REV PROJECT NAME & ADDRESS a rn Z) C N O 00 Q o o Q � ~ to tY uJ NT O Zz rn O O C) 2 z LU w o o . � d Z F- a 0 rn N N N DATE: 8/13/2022 SHEET NAME EQUIPMENT SPECIFICATIONS SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-14 1. CONCEALED UNIVERSAL CEAYPS ," F„ SOLARMOUNT BETTER DESIGNS TRUST THE INDUSTRYES BEST DESIGN TOOL Suit 1lx t • It's aQftat a, . •.,.. , BETTER SYSTE F ONE SYSTEM - MANY APPLICATIONS Cuc►,y soo nceuks limb is toe no as 9w wkd am& Owl a torte wanly W nlfules is PoIrA or lartfltcapt Tilt tit splrn sp to Ilal or Ittr sin rich Gems►1111teablicinnil. claf.aid fvf t( •T t!ttulft1a'llrtll;J1 and atstAthcs BETTER RES11ITll� MAXIMIZE PROFITABILITY ON EVERY JOB t,li, It u ; ,u ntnn 7, 1, : lie lint tic W uAlldItvlatbnctcattartatetIII t feet, fag& *%falls trsswule Yt"pit, . UNIRAC CONCEALED UNIVERSAL FNDCLAMPS L END CAPS INCLUDEO WITH EVERY ENOCLAMP UNIVERSAL SELF �ii+�anr BETTF9 SUPPOP- STANDING MIDCLAMPS �I 25WORK Wk- ...ITH T... ),,!HE INDUSTRIES MOST EXPERIENCED TEAM «= "wil st"trt aid lrlttttE P9111 w,llcm 1tv ftpltft nppl;• aC it ell OPTIONAL YEAR FRONT TRIM N,IkiIM;' U•BUILDER ONLINE DESIGN TOOL SAVES TIME t MONEY o UL2703,,�"`OxmVIS11lksgs.uufaccu' U,> UNIRAC CUSTOMER SERVICE MEANS THE HIGHEST LEVEL OF PRODUCT SUPPORT NOW FEATURING FIASHKIT PRO NOW WITH UNIVERSAL MIOCLAMPSREVOLUTIONARY 1 tAsfcreu •�I,,: eRlgAtfY r1.�.w qun+ 0SHIMISSM mcnaft, r _ — TECHNICAL SUPPORT CERTIFIED OIIALFTY PROVIDER BANKABIE WARRANTY Wtwe'sledwttl tgplll MIAs I to aeasa*t Ufrac n Ue tMt W naustr� wrlr anQ c50 Qon' I kale ton polled Is drat, Uwx An tit amli "9 allltmiK bm im ial bm. At o lit m1 t0w Iv9001M.1NI0121IO4 xW 0HSAS twl w sll�Illr lttktr pMoels oUnia wet rsk THE PROFESSIONALS' CHOICE FOR RESIDENTIAL RACKING WkmOlw u"avlIt 1'NK al« •r-•!Ir.,i;'•--nlltgaultroltclptaugpatu at1 , zd00trtlltltliRcluslieiimpl%fim fdWpfOWrY1QIfY7A�a.51R7tG1�b�llrpttil/ BEST INSTALLATION EXPERIENCE* CURB APPEAL* COMPLETE SOLUTION • UNIRAC SUPPORT I QUESTIONS OR CUSTOMER SERVICE VISIT UNIRAC.COM OR CALL (505) 248-2702 t:.11ANCE YOUR REPUTATION WITH QUALITY RACKING SOLUTIONS BACKED BY ENGINEERING EXCELLENCE AND A SUPERIOR SUPPLY CHAI.4 FOR OUESTIONS OR CUSTOMER SERVICE VISIT UNIRAC.COM OR CALL (505) 248-2702 man SMSOLAR APPENDIX C 1 N an ; MOUNT UNIV[ RSALAF INDCLAMP Ili 1ON GUIDE: PAGE ............................................................................................................................................. 1. Position clamp to align T-bolt with rail Mot. toner damp and Insert T-bolt into rail Slot. 2. Rotate damp clockwise 2/3 of a turn 3. Place module at Least 3/4' from and of 4. While applying pressure to hold the to engage T-boll inside rail slot. rail and position clamp against module clamp against the module. push down or,. frame. the module side of the clamp cap. � _ M ww 17 a yt ter. 15 tr Zee S. When the cap contacts the rtodiLt 6 T.grge� brAe and torpst to Is It-1bs. T CNrlh.t c Laro .s co)#Wd r- CW-ftt nol.le nt.yt cost, o• an4 tvt rt tap efMe frame, release and it will re-engage to tap is Sftn lry i oath the mtiCale flame. the clamp base. rMTE: When installing 46mm modules, loosen bolt by 1 turn before positioning clamp against module frame. Do not force clamp onto module frame as this may darriage the bonding pin. oneSM SOLAR CODE COMPLIANCE NOTES i A •• I. MOUNT r�:..__...:�N GUIDE ; PAGE .................................................................................................................... SYSTEM LEVEL FIRE CLASSIFICATION The system fire class rating requires installation in the manner specified in the SOLARMOUNT Installation Guide. SOLARMOUNT has been classified to the system level fire portion of UL2703. SOLARMOUNT has achieved system level performance for steep sloped roofs. The fire classification rating is only valid on roof pitches greater than 212 (slopes 3 2 inches per foot, or 9.5 degrees). The system is to be mounted over fire resistant roof covering rated for the application. There is no required minimum or maximum height Limitation above the roof deck to maintain the system fire rating for SOLARMOUNT. Module Types. System Level Fire Ratings, and Mitigation Rsquirt+munts are UsW below: allp "embmevan silimma"lUafA" ll abeam a�w 1•ry+w• �� IMM1re0 9111a•a a 10 antic L 2. 3 rtdlrt tenth twm W vM N" 0MA IM a • 0M C tunic taaawgs a llfrmt Mry tp, w lra•attIL3,LMff,10 hurt► smo Loftaataf ow IwaaNwa U"art I•! 0MACatat••CUNC bw•a4n UWWWahaft la"&me w t>rra►Srre+ u0mi t a rhrttaa Itw err Sa.maii.1 R6 44S QmA.Ckm6&0 tC tartwtt IMUOMWottlmvaa trrtIrmi mt,PerUw to mob rSsuh LOOK a.art76w ttanarataata•ooAft T" rac%Ing system nu be used to pto.nd aMla rrsuwrt a PV rnWtsA com;()%ng with UL 1703 or Lk 6:: 50 only v."m the tpt(rfK m)6.11e his tetn t.+cuXtd'u o-o_+sAno rd!-r mc.rnting'n cOm'llmce wrh the nclu7e1 Irtnrtlri 1.11L2TO) C811TVICATION NMKINC. Mal URNK Unirac $OIAtMOUNT is UVA4 to UL 2205 CtttrfKatlon -wting is tmbdsstd on aU rrsd CII&O s an y+v+K+. libels wrh addtrpeul r4otmatwn will to protidtd . Afttt the racllrig systtm is Wy assembGe t a single Law should be applied to ov • $(XARNOUN T rail at the CNe of tht array, wain• A"IlwrE ue LtOaL ttr lawns altAa U60 wit de •at oarlatrt a Ora 8Tse.w eoirg limullb d am*be nwt•rrd to that ** dw Yta sil•0 oytea•t 4w is Owail t* C C40 lJ3 21i6M SMSW111�ML S?I IIOffM� Lumio SIVIART ENERGY TODAY (SET) 1550 DIGITAL DR, LEHI, UT 84043, USA SYSTEM INFO (12) Q CELLS Q.PEAK DUO BLK ML-G10+ (400W ) (12) ENPHASE IQ8PLUS-72-2-US (240V) DC SYSTEM SIZE: 4.80 kWDC AC SYSTEM SIZE: 3.60 kWAC REVISIONS DESCRIPTION I DATE I REV PROJECT NAME & ADDRESS a U) Z) O N O 00 Q O O C) NT 0' W O p Z Z rn O p 2 C4 zLLUU w> o O � d Z D_ = a F— CO O CA N N N DATE: 8/13/2022 SHEET NAME EQUIPMENT SPECIFICATIONS SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-17 $M ••'sOLAp BONDING CONNECTION GROUND PATHS: 0 u�� MOUNT _moNsmou ens[ 4 Lima a „A „ r.s r� N0 BOND" 114WLAMPASSEMKY BONOM16MWQAMPASSE4BLY DOIOPIG RAIII SPLICE am IMlLT04400TIVWW fiT.YOIT u"T.vT nc:Jl�J nrr rl)r,r,ttw.i: �! r•^-r YM a r•MYltw flaMrn M•• OT.....aywNrl.....�t e..l .+.a.-.n `� K aM that aware ace.. ra+e ar .x .«e .H .'tram n Oatr tf ea u rs+w rs ' eo[ awed dies+ b »+! *eea7<l6 rnon.te :n.00gf+ tlax,. y...... .w. I- wl ..... ..1 r M7 r+ A sr.w r Dolt head penntates rai::r6elmtan ©Saw %A bv21j Alinuia c Lamp to stainless steel T•boll """'de "b- 6'+'butt, m,a:CL-NM1oyar�ad . w..., .. e�..e. sre,rt ©U Md '-tdt Mad arees•a ec •y: a w6rxlon ro Oard T-aalc rwc r1awRa+e "Gahm to %"'.I .• E p � MOIOwr'nl. i� �t w IrowtT eOeOwc l'ccta.e► 4t71Y�! / I A r I Iw To L rooT Ire ..r w, (Arm t10rOatL r w.rr• ,�i� TOW "DIMDRIG NICROIHYIRTu MOUNT kirk- — M A4..Yr/ © �.ter♦eM rare b Ysr.ml sUrt '.]ca 0 SWMW T4ea lie.[ r�— •.4 H" 24 no E W=LUC tOa KX0 Llh. 0 RACK SYSTFM GROUND tr ©WM MOw o:m)ics Pierce ario6ize6 rail to lft bW Par .- roes zn6 Lp Otw.'we. we ww�wla 1..E • .Iles- r .a•r• r"M Ina.. e.-a 6,..a.. n •e: SOLAR •• ; MOUNT 0 t r 1 INSTALL MODULE DO CLAMK: TM End clamp is u pp.rd an an Mwrrbiy wth a W' hex head hott that rs amiftshle at the er'dt Cr rails. The clamp should be IrMSUM o'� me rails prior to installing end mod.tes fN5TALL FIRST MODULE: Install the first end ntodute onto rails with the flange of the module frame positioned between end clamps an ends of rails. ENDCLAMP, FIRST MODULE: L PAGE 0 go go No MKTALL END CLAMS ON MAIL: SI ov end c tamp on to tac by ew.a.in; the tAo Ipude brackets atM the top slot d"rails. boa o eatsarded as tar as pass.tue H,rr ,r:,.,: : . a-... A d —." POSIT1011 END CLAMrS Sbd► R-d c lane aswmt(y on to •sll unbl bcAt hcW enpapes with end or ralt End dawo are peubooed on r2as prim to b%k, Intl erd m-)d•le and pe or to the Imt ENGAGE CLAMP: While holding rr.xt.li n position and wah flange in full contact with rail, rml re end (amp tall wail clump egMs with dwge to promde clamp fan. lb ernwe bole Is not wee-WrTlot4 use low Wgwe setting on *% or H wong an enpW delver, stop rotation a1 soon as inW aet;on of drretf beglm. 5 ft-S& No anti WUN AV f t. To it" Imer." cr Llano kft mg Nat, wwwre rwy be applied to top or side of beadd as shores- Do rnt Moro dare UIo all by p "" on bell with esmahe theca r -' tr I� VY ear t!a ae/arrs•rr p.rre.. T.aava ►.,n lelr rnOt p ra It Plat snaAf wet ear.t �w•e t ter/ t/7' aetav r 11tlwM ew >r ash -- t.41 P p rant stl tarecc ow.ewa rvT dnit Lumio SIVIART ENERGY TODAY (SET) 1550 DIGITAL DR, LEHI, UT 84043, USA SYSTEM INFO (12) Q CELLS Q.PEAK DUO BLK ML-G10+ (40OW ) (12) ENPHASE IQ8PLUS-72-2-US (240V) DC SYSTEM SIZE: 4.80 kWDC AC SYSTEM SIZE: 3.60 kWAC REVISIONS DESCRIPTION I DATE I REV PROJECT NAME & ADDRESS a 1) Z) 0 N 00 a O O a � ~ U w o NT O Z O z rn Nt O wp 2 Z LU LLI o O d Z = a H CO O N N N DATE: 8/13/2022 SHEET NAME EQUIPMENT SPECIFICATIONS SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-18 P72 P.,/; t(�J(�iNRS tNC�1N�`t January 12, 2022 Unirac Components and Cladding Roof Zones: 1411 Broadway Blvd. NE The Components and Cladding Roof Zones shall be determined based on ASCE 7-05, ASCE 7-10 & 7-16 Camponsnt.and Albuquerque, NM 87102 Cladding design. Attu.: Unirac - Engineering Department .Notes: 1) U-builder Online tool analysis -is only for Unirac SM SOLARMOUNT Rail Flush systems only and.do..not include roof capacity check. Re: Engineering Certification for the Unirac U-Builder 2.0 SOLARMOUNT Flush Rail 2) ,Risk Categary.H per ASCE 7-16. 3) Topographic factor, kzt.is 1.0, PZSE, Inc. - Structural Engineers has reviewed the Unirac SOLARMOUNT rails, proprietary mounting system constructed 4) Array Edge.F.actor YE =1.5 from modular parts which is intended for rooftop installation of solar photovoltaic (PV) panels; :and has reviewed the U- 5) Average. parapet .height is.0.0 ft. builder Online tool. This U-Builder software includes analysis for the SOLARMOUNT LIGHT rail, SOLARMOUNT 6}.Wind speeds are LRFD values. STANDARD rail, and SOLARMOUNT HEAVY DUTY rail with Standard and Pro Series hardware. All information, .data and 7) Attachment spacing(s) apply to a seismic design category E or less. analysis. contained within -are based'on, and comply with the following codes and typical specifications: 1. Minimum Design Loads for Buildings and other Structures, ASCE/SEI 7-05, ASCE/SEE 7-10, ASCE/SEI 7-16 Design Responsibility: 2, 2006:2018 International Building Code, by International Code Council, Inc. w/ Provisions from SEAOC PV-2 2017. The U-Builder design software is intended to be used under the responsible charge of a registered design professional. 3. 2006-2018 International Residential Code, by International Code Council, Inc. w/ Provisions from SEAOC PV-2 where required by the authority having jurisdiction. In all cases, this U-builder software should be used under the '2017. direction of a design professional with.sufficient structural engineering knowledge and experience to be able to: 4. AC428, Acceptance Criteria for Modular Framing Systems Used to Support Photovoltaic (PV) Papels,.Novem..t r Evaluate whether the U Builder Software is applicable to the project, and 1, 2012 by [CC -ES. • Understand and determine the appropriate values for all input parameters of the U-Build.er software. 5. 2015 Aluminum Design Manual, by The Aluminum Association, 2015 Following are typical specifications to meet the above code requirements: Design Criteria.:.... Ground Snow Load = 0 -100 (psf) Basic Wind Speed = 85 -190 (mph) Roof Mean Height = 0 - 60 (ft) Roof Pitch = 0 - 45 (degrees) Exposure Category = B, C & D Attachment Spacing: Per U-builder Engineering report. Cantilever: Maximum cantilever length is L/3, where "L" is the span noted in the.U-Builder online tool. Clearance: 2" to 10" clear from top of roof to top of PV panel. Tolerance(s): 1.0" tolerance for any specified dimension in this report is allowed for installation. Installation Orientation: See SOLARMOUNT Rail Flush Installation Guide. Landscape - PV Panel long dimension is parallel to ridge/eave line of roof and.the PV panel is mounted on the long side. Portrait - PV Panel short dimension is parallel to ridge/eave line.of roof and the PV panel is mounted on the short side. 1478 Stone Point Drive. Suite 190. Roseville. CA 95661 916.961,3960 916.961.3965 wvnri.pzso.com 1 of 2 This letter certifies that the Unirac SM SOLARMOUNT Rails Flush, when Installed according to the U-Builder engineering, report and the manufacture specifications, is in compliance with the above codes and loading criteria.. This certification excludes evaluatbon of the following components: 1) The structure to support the bads imposed on the building by the array; including, but notIim.'ited to:,strength and deflection of structural framing members, fastening and/or strength of roofing materials, and/ort#1e. effects of snow accumulation on the structure. 2) The attachment of the SM SOLARNIOUNT Rails to the existing structure. 3) The capacity of the solar module frame to resist the loads. This requires additional knowledge of the building and is outside the scope of the certification of this racking system. D IGITALLY SIGNED If you have any questions on the above, do not hesitate to call. Prepared by. PZSE, Inc. — Structural Engineers Roseville, CA c rMt OE/D7./Y02 1478 Stone Point Drive. Suite 190, Roseville. CA 95661 916.961.3960 916.961.3965 www.pzso.com 2 of 2 Lumio_ SMART ENERGY TODAY (SET) 1550 DIGITAL DR, LEHI, UT 84043, USA SYSTEMINFO (12) Q CELLS Q.PEAK DUO BLK ML-G10+ (400 W ) (12) ENPHASE IQ8PLUS-72-2-US (240V) DC SYSTEM SIZE: 4.80 kWDC AC SYSTEM SIZE: 3.60 kWAC REVISIONS DESCRIPTION I DATE I REV PROJECT NAME & ADDRESS Q L7 0 N O 00 rn Q o CD a � L7 W ❑ o O z z rn 2i w O It w LU 0 O Z 11 = a _o N N N DATE: 8/13/2022 SHEET NAME EQUIPMENT SPECIFICATIONS SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-20