APPROVED BLD BLD2021-1099+Architectural_Plan+8.8.2021_10.33.59_PM+2345322ABBREVIATIONS: ABV ABOVE AFF ABOVE FINISH FLOOR BLDG BUILDING BLKG BLOCKING BM BEAM BOT BOTTOM CIPC CAST -IN -PLACE CONCRETE i CENTERLINE CLG CEILING CLR CLEAR CMD CARBON MONOXIDE DETECTOR CO CLEANOUT CONIC CONCRETE CONT CONTINUOUS D DRYER DBLE DOUBLE DEMO DEMOLISH DIA DIAMETER DIN DOWN DP DEEP DP DIMENSION POINT DS DOWNSPOUT DTL DETAIL DW DISHWASHER (E) EXISTING EA EACH ELEV ELEVATION EQ EQUAL EXT EXTERIOR EW EACH WAY *EW EGRESS WINDOW FDN FOUNDATION FIG FINISH GRADE FIN FINISH FL FLUSH FLR FLOOR FOF FACE OF FINISH FOS FACE OF STUD FRMG FRAMING FRZR FREEZER FT FOOT FTG FOOTING FV FIELD VERIFY FV FOUNDATION VENT GA GAUGE GB GYPSUM BOARD GLB GLULAM BEAM GSM GALVANIZED SHEET METAL HDR HEADER HGR HANGER h HIGH HT HEIGHT HVAC HEATING, VENTILATION, & AIR-CONDITIONING IG INSULATED GLASS INT INTERIOR LAV LAVATORY LBS POUNDS LF LINEAR FEET LO LOW MAX MAXIMUM MFR MANUFACTURER MIN MINIMUM (N) NEW N/A NOT APPLICABLE NIC NOT IN CONTRACT 0/ OVER OC ON CENTER OG OBSCURE GLAZING OH OVERHANG P.L. PROPERTY LINE PL PLATE PT POINT PTW PRESERVATIVE TREATED WOOD REBAR REINFORCEMENT BAR REFR REFRIGERATOR REQD REQUIRED REQTS REQUIREMENTS RAFT RAFTER RO ROUGH OPENING R.O.W. RIGHT-OF-WAY RFT RIP -TO -FIT RTS RIP -TO -SLOPE RV RIM VENT SC SOLID CORNER SD SMOKE DETECTOR SF SQUARE FEET SG SAFETY GLAZING SHWR SHOWER SIM SIMILAR SPEC SPECIFICATIONS SQ FT SQUARE FEET SQ IN SQUARE INCHES STD STANDARD SUBFLR SUBFLOOR T&G TONGUE & GROOVE THK THICK TOPO TOPOGRAPHY TOW TOP OF WALL TYP TYPICAL UNO UNLESS NOTED OTHERWISE VTO VENT TO OUTSIDE w WIDE W WASHER W/ WITH WC WATER CLOSET WFC WOOD FRAME CONSTRUCTION WH WATER HEATER WIC WALK -IN -CLOSET WP WORK POINT WWF WELDED WIRE FABRIC Peterson Interior Garage Alteration ENERGY CODE COMPLIANCE NOTES: 2018 WASHINGTON STATE ENERGY CODE CHAPTER 4 PRESCRIPTIVE COMPONENT TABLE R402.1.1 — ZONE 4C LOCATION INSULATION REQUIREMENTS FENESTRATION (UNLIMITED) U=0.30 OR BETTER SKYLIGHT (UNLIMITED) U=0.50 OR BETTER GLAZING FENESTRATION SHGC NR CEILING R-49 CEILING VAULTED R-38 WOOD FRAME WALL R-21 INT MASS WALL R-21 FLOOR R-30 BELOW -GRADE WALL R-10/15/21 INT-TB SLAB R-10, 2 FT. WINDOW & DOOR HEADERS R-10 MIN NOTE: 1) R-10 CONTINUOUS INSULATION IS REQUIRED UNDER HEATED SLAB ON GRADE FLOORS. SEE SECTION R402.2.9.1. 2) R7.5 CONTINUOUS INSULATION INSTALLED OVER AN EXISTING SLAB IS DEEMED TO BE EQUIVALENT TO THE REQUIRED PERIMETER SLAB INSULATION WHEN APPLIED TO EXISTING SLABS COMPLYING WITH SECTION R503.1.1. ENERGY CREDITS CODE COMPLIANCE NOTES: 2018 WASHINGTON STATE ENERGY CODE CHAPTER 4 ADDITIONAL ENERGY EFFICIENCY REQUIREMENT PER SECTION R406.2 PROJECT TO MEET "ADDITIONS LESS THAN 500 SQUARE FEET" REQUIREMENTS OF 1.5 CREDITS FROM TABLE 406.2 ENERGY CREDITS: OPTION 2: FUEL NORMALIZATION DESCRIPTION 1.0 CREDITS HEAT PUMPc c. EQUIPMENT LISTED IN TABLE C403.3.2(1) OR C403.3.2(2) OPTION 3.2: EFFICIENT HVAC EQUIPMENT OPTION 1.0 CREDITS AIR -SOURCE CENTRALLY DUCT HEAT PUMP WITH MINIMUM HSPF OF 9.5. OPTION 5.2: EFFICIENT WATER HEATING OPTION 0.5 CREDITS ENERGY STAR RATED GAS OR PROPANE WATER HEATER WITH A MINIMUM UEF OR 0.80. P1 SW a' 187m P1 SW — 6 3 — O0 3 187th St SW m T ^ S m 187th PI SW D St SW 188th St SW 188th St Sw 188th St SW PI Sw 0 189th PI Sw 77 6 D o t PI SW op ' 91" Pi SN Q $terju ParA: n v 191 St St SW F � 1921d St SW 6410 ^ St > 2nd W Sierra Dr 4 192,d P1 Sw F 4 193,d PI SW 19_ 19<th St SW 3 3 > ' 1940 L s L D W C F m W 1951 19 th St SW su s:a su f•SY PROJECT LOCATION N VICINITY PLAN: SCALE: NOT TO SCALE SITE LOT AREA LOT AREA: (0.46 ACRES) 20,000 S.F. DOOR SCHEDULE (MFR & MODEL OR EQUAL) IDEN TYPE DOOR SIZE ROUGH OPENING MATERIAL QUANTITY TOTAL AREA U- FACTO R (MIN OR BETTER NFRC-CERTIFIED) MFR NOTES WIDTH HEIGHT WIDTH HEIGHT D01 SINGLE PANEL 3'-0" 6'-8" 3'-2" 6'-10" FIBERGLASS WOODCLAD 1 20.00 0.28 TBD (ENERGY CREDIT OPTION 1.3) D02 SINGLE PANEL 2'-6" 6'-8" 2'-81) 6'-10" WOOD 3 - - TBD D03 PAIRED BI-FOLD 6'-0" 6'-81) 6'-1" 6'-10" WOOD 1 - - TBD D04 PAIRED FRENCH 5-0" 6'-8" 5'-21) 6'-10" WOOD 1 - - TBD D05 SINGLE PANEL 2'-10" 6'-81) 3'-01) 6'-10" WOOD 1 - - TBD NOTES: (1) FINISH FLOOR 4'-0$) O e 3'-0" o e IDEN TYPE MATERIAL SIZE WIDTH HEIGHT W01 SLIDER VINYL 4'-0$$ 4'-0" W02 SINGLE HUNG VINYL 3'-0" 3'-0'$ W03 SLIDER VINYL 5-0" 4'-0'$ W02 AWNING VINYL 4'-0" 2'-0'$ 5-0" 4'-0" N / \ O T FINISH SPECIFICATION: (A) FLOOR S e WINDOW SCHEDULE (MFR & MODEL OR EQUAL) ROUGH OPENING TOTAL WIDTH HEIGHT QUANTITY AREA SPEC 4'-0" 4'-0" 4 64.00 SF (A) DESCRIPTION 3'-0" 3'-0" 1 9.00 SF (A) 5-0" 4'-0" 1 20.00 SF (A) 4'-0)$ 2'-0" 1 8.00 SF (A) OBSCURED & SAFETY GLAZING TOTAL QUANTITY 7 101.00 SF TOTAL AREA (SQUARE FEET) NOTES: SPECIFICATION: (1) (A) ALL GLAZING TO HAVE U-FACTOR = 0.28 MAX OR BETTER; NFRC-CERTIFIED (ENERGY CREDIT OPTION 1.3) PROJECT CONTACT INFORMATION: OWNER: Trevor & Jessica Peterson 8410 192nd St SW Edmonds, WA 98026 DESIGNER: Calvin Tam 10040 Sand Point Way NE Seattle, WA 98125 PROJECT PROPERTY INFORMATION: PROJECT ADDRESS: 8410 192nd St SW Edmonds, WA 98026 LEGAL DESCRIPTION: SEC 18 TWP 27 RGE 04RT-19C-5) S 100 FT OF N 130 FT OF W 200 FT OF E 220 FT OF E1/2 NE1/4 SE1 /4 SW4 ASSESSOR'S TAX NUMBER: 27041800306900 LAND USE ZONE: RS-10 PROJECT DESCRIPTION: INTERIOR ALTERATION TO EXISTING SINGLE FAMILY RESIDENCE TO CONVERT EXISTING ATTACHED GARAGE & UTILITY AREA INTO LIVING SPACE. CODE INFORMATION: APPLICABLE CODES (AS AMENDED BY WA STATE, SNOHOMISH COUNTY & LOCAL JURISDICTION): 2018 INTERNATIONAL RESIDENTIAL CODE (IRC) 2018 NATIONAL ELECTRICAL CODE 2018 UNIFORM PLUMBING CODE (UPC) MECHANICAL CODE PER 2018 WASHINGTON STATE ENERGY CODE, 2018 EDITION (WSEC) WASHINGTON STATE VENTILATION AND INDOOR AIR QUALITY CODE, 2018 EDITION (VIAQ) OCCUPANCY: GROUP R-3 (SINGLE-FAMILY RESIDENTIAL) NOTE: ELECTRICAL PLAN AND SYSTEM TO BE DESIGNED BY INSTALLING CONTRACTOR AND SHALL CONFORM TO ALL APPLICABLE CODES & REGULATIONS. PLUMBING PLAN AND SYSTEM TO BE DESIGNED BY INSTALLING CONTRACTOR AND SHALL CONFORM TO ALL APPLICABLE CODES & REGULATIONS. HEATING & MECHANICAL VENTILATION SYSTEM TO BE DESIGNED BY INSTALLING CONTRACTOR AND SHALL CONFORM TO ALL APPLICABLE CODES & REGULATIONS. ELECTRICAL, PLUMBING & MECHANICAL TO BE UNDER SEPARATE PERMIT SUBMITTAL. PROJECT SQUARE FOOTAGES: EXISTING RESIDENCE (E) MAIN FLOOR LIVING AREA: (E) ATTACHED GARAGE & UTILITY AREA (UNFINISHED SPACE): EXISTING TOTAL LIVING AREA: TOTAL EXISTING RESIDENCE & PROPOSED CONVERSION (E) MAIN FLOOR LIVING AREA: (E) CONVERT GARAGE & UTILITY FLOOR AREA TO LIVING SPACE: PROPOSED TOTAL LIVING AREA: INDEX OF DRAWINGS: T1.0 A1.0 A2.0 A3.0 2,048 SF 485 SF 2,821 SF 2,048 SF 485 SF 2,533 SF GENEKAL IWORMAIIUN, SHE PLAN & ABBKEVIAIIUNS ALL WORK SUBJECT SECTION & DETAILS TO FIELD DEMO PLAN & DETAILS INSPECTION FOR FRAMING PLAN & DETAILS CODE COMPLIANCE FLOOR PLAN & DETAILS OBTAIN ELECTRICAL PERMIT FROM STATE LABOR & INDUSTRIES APPROVED PLANS MUST BE ON JOB SITE City Of Edmonds B❑ilding De❑artment Woru ------------------------------------------------------ GARAGE CONVERSION -------------------------------------------------- Address -------------------------------------------------- 8410 192ND ST SW ------------------ Ou ner ------------------- PETERSON A uu roved Date 9 ❑ 01 112021 Building Official W. c0fALa_xc ---- ------------------------------------------ Perm it N-1muer BLD2021-1099 ------------------- TAM Design 10040 Sand Point Way NE Seattle, WA 98125 calvint006@gmail.com Peterson Interior Garage Alteration 8410 192nd St SW Edmonds, WA 98026 Permit Set Date: Description: 08/09/21 Permit Intake Project No.: 2150.00 Drawn: RECEIVED Aug 09 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT GENERAL INFORMATION, SITE PLAN & ABBREVIATIONS Sheet No: T1,0 TAM Design 10040 Sand Point Way NE Seattle, WA 98125 calvint006@gmail.com Hb PEf INS PEE FRF PEE SILL CAS INSI PEF HEAD DETAIL SCALE: 3"=1 '-0" JAMB DETAIL SCALE: 3"=1 '-O" WALL ASSEMBLY PER PLAN SHEET METAL HEAD FLASHING 20" CLEAR OPENING c� MINIMUM REQUIRED z ^ NET CLEAR a- o S OPENING AREA IS o w 5.7 S.F. Q 2 w J I0 C:) � OPENINGS AT THE U _ CD GRADE FLOOR MAY BE REDUCED TO 5 S.F. CD z MINIMUM SIZE = WINDOW FOR 20" z o CLEAR WIDTH w ry ::5Q O w y U X o Q :2i rr, 0 �o �__j 34" CLEAR OPENING (30" IF ON ol GRADE FLOOR) i MINIMUM SIZE WINDOW FOR 24" CLEAR HEIGHT Q� J z c� z w n 'to N FINISH FLOOR BASEMENTS, HABITABLE ATTICS AND EVERY SLEEPING ROOM SHALL NOT HAVE LESS THAN ONE OPERABLE EMERGENCY ESCAPE AND RESCUE OPENING. WHERE BASEMENTS CONTAIN ONE OR MORE SLEEPING ROOMS, AN EMERGENCY ESCAPE JOINT SEALANT AND RESCUE OPENING SHALL BE REQUIRED IN EACH SLEEPING ROOM. EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL OPEN DIRECTLY INTO A PUBLIC WAY, OR TO A COURT OR YARD THAT OPENS TO A PUBLIC WAY. WALL ASSEMBLY PER PLAN JOINT SEALANT WINDOW WINDOW JOINT SEALANT WALL ASSEMBLY PER PLAN MINIMUM RESIDENTIAL EMERGENCY EGRESS OPENING REQUIREMENTS SCALE: 1 /2"=1'-O" FLASHING @ HEAD OVERLAP STEP #1 STEP #2 FLASHING OF EXTERIOR WALL OPENINGS: WINDC SCHE[ (E) DRIV JAMB FLASHING n1 vvOW FRAME ` ' INSULATION, TYP ON GRADE IINJULHIIUIN 2 A3.0 FLASHING UNDER BLDG PAPER � FLASHING OVER BLDG PAPER STEP 3 INDIVIDUALLY FLASH ALL EXTERIOR OPENINGS FOR FIXTURE SUCH AS WINDOWS, DOORS, AND VENTS TO MAKE THEM WATERRPROOF. FLASHING MATERIAL SHALL BE MOISTOP BY MANFUL. SEALANT SHALL BE COMPATIBLE AND APPROVED BY MANFUL. IN HIGH WIND AREAS W.R. GRACE ICE & WATER SHIELD SHALL BE USED, OVER SOLID BACKING. FLASHING MATERIAL AT LEAST 9" WIDE SHALL BE APPLIED IN A WEATHER BOARD FASHION, BEGINNING WITH THE SILL WITH A STRIP LONG ENOUGH TO PROJECT BEYOND THE JAMB FLASHING TO BE APPLIED. THE TWO JAMB FLASHING ARE THEN APPLIED WITH SUFFICIENT LENGTH TO EXTEND BEYOND THE SILL FLASHING, AND WITH THE SAME DISTANCE AT THE TOP. FOR FIXTURES WITHOUT NAIL —ON FLANGES, THE FLASHING SHALL BE 12" MIN. WIDTH AND EXTEND INTO THE ROUGH FRAME AT THE SILL AND JAMB. FOR NAIL —ON FLANGE FIXTURE, INSTALL BY PRESSING FLANGE POSITIVELY INTO A CONTINUOUS BEAD OF SEALANT WHICH EXTENDS AROUND THE BOTTOM AND SIDES OF THE FIXTURE. APPLY THE TOP HORIZONTAL FLASHING LAST, WITH SUFFICIENT LENGTH TO EXTEND BEYOND THE JAMB FLASHING. OVERLAP AND SEAL AGAINST THE THE TOP NAILING FLANGE OR G.S.M. HEAD FLASHING WITH A CONTINUOUS BEAD OF SEALANT. APPLY REMAINING WALL SHEATHING PAPER IN A WEATHERBOARD FASHION WITH THE SILL FLASHING LAPPING OVER THE TOP AND THE HEAD AND JAMB FLASHING BELOW. BUILDING SECTION SCALE: 1 /2"=1 '-O" Tin � Tnr n n�. 1 1 /4" MIN AT OUTSIDE OF STAIR r1 TYPICAL HANDRAIL DETAIL SCALE: NTS HANDRAIL AND GUARDRAILS SHALL BE CONSTRUCTED AS FOLLOWS: GUARDRAILS SHALL NOT BE LESS THAN 36" IN HEIGHT. HANDRAILS SHALL NOT BE LESS THAN 34" OR MORE THAN 38" IN HEIGHT ABOVE THE STAIR NOSING. x Q OPEN RAILS SHALL HAVE INTERMEDIATE RAILS OR AN ORNAMENTAL PATTERN SUCH AS A 4" DIAMETER SPHERE CANNOT PASS `n THROUGH. THE TRIANGULAR OPENINGS AT STAIR TREAD, RISER & BOTTOM SHALL BE SUCH AS A 6" DIAMETER SPHERE CANNOT PASS THROUGH. THE HANDRAIL CONSTRUCTION SHALL BE ABLE TO RESIST A LOAD OF 200 LBS APPLIED IN ANY DIRECTION AT ANY POINT ALONG THE TOP RAIL. THIS DIAGRAM ILLUSTRATES THE SPECIFIC REQUIREMENTS OF THE BUILDING CODE AND IS ONLY AN AID FOR CONSTRUCTION 1 1 /2" MIN RETURN TO WHERE SHC SEE PLAN C PLAN NOTE: HANDRAIL & INSTALLATION SHALL MEET THE REQTS OF THE 2018 IRC. FOR SPECIFIC CODE REQTS FOR GUARD & HANDRAILS SEE DETAILS THIS PAGE NOTE: HANDRAIL & INSTALLATION SHALL MEET THE REQTS OF THE 2018 IRC. 200 LBS ANY DIRECTION ANY LOCATION 6" SPHERE MAY NOT PASS THROUGH J z 4" SPHERE MAY NOT PASS THROUGH w Of 0 0-1 0 Peterson Interior Garage Alteration 8410 192nd St SW Edmonds, WA 98026 Permit Set Date: Description: 08/09/21 Permit Intake Project No.: 2150.00 Drawn: RECEIVED Aug 09 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SECTION DETAILS Sheet No: SILL DETAIL SCALE: 3"=1 '-O" TYPICAL WINDOW OPENING FLASHING REQUIREMENTS SCALE: NOT TO SCALE TYPICAL INTERIOR TREAD RISER DETAIL SCALE: NTS TYPICAL HANDRAIL /GUARDRAIL DETAIL SCALE: NTS TAM Design 10040 Sand Point Way NE Seattle, WA 98125 calvint006@gmail.com IN MAIN ENTRY --- ---------------------------------------♦ 4'-0" ol 5'-0" 3'-0" 10 NEW NEW WINDOW REMOVE (E) NEW WINDOW REMOVE (E) WINDOW OPENING WINDOW OPENING WINDOW OPENING I I I I I I I I REMOVE (E) WINDOWS, PREP FOR NEW DOOR I I I I I I I I I I I I I I REMOVE (E) WINDOWS I I I I I I I I I I I I MAIN FLOOR EXISTING & DEMO PLAN SCALE: 1 /4"=1 '-0" AREA OF WORK 0 NORTH 0 5 10 GRAPHIC SCALE LEGEND (E) 2x WALL CONSTRUCTION. EXISTING CONSTRUCTION TO BE REMOVED. (E) 2x WALL CONSTRUCTION. FIELD VERIFY THICKNESS AND ADDED FURRING TO MEETING R-21 INSULATION VALUE. � 2x6 EXTERIOR WALL CONSTRUCTION (W/ R-21 INSULATION). � 2x4 INTERIOR WALL CONSTRUCTION. (E) DOOR TO BE SALVAGED OR REMOVED (E) DOOR TO REMAIN NEW OR RELOCATED DOOR x SMOKE DETECTOR (IRC - SECTION R314) SD X CARBON MONOXIDE DETECTOR (IRC - SECTION R315) CMD EXHAUST FANS: MIN. 50 CFM FOR BATHROOM AND LAUNDRY; MIN. 100 CFM FOR KITCHEN, WITH DIRECT VENT TO EXTERIOR Peterson Interior Garage Alteration 8410 192nd St SW Edmonds, WA 98026 Permit Set Date: Description: 08/09/21 Permit Intake Project No.: 2150.00 Drawn: RECEIVED Aug 09 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT DEMO PLAN DETAILS Sheet No: (E) INDICATES EXISTING FIXTURE Anchor bolts to be installed as per sections 403.1.6 and 403.1.6.1 of 2018 IRC INC LANDING D STEPS C LJ urti\imu MAIN ENTRY 3/4" FLOOR - SHEATHING 4x6 PTW CURB 2" MIN TO CONIC (E) CONIC SLAB DRIVEWAY MAIN FLOOR FRAMING PLAN SCALE: 1 /4"=1 '-0" WALL ASSEMBLY PER PLAN FINISH FLOOR PER OWNER In 2x PTW LUMBER @ 24" OC MAX RIPPED TO MATCH SLOPE OF SLAB, TYP RIGID INSULATION PER PLAN (E) SLAB ON GRADE 1 /2"x6.5" SCREW ANCHORS @ 6 FT OC MAX WITH 3" 0 x0.25" PLATE WASHERS 4'-0" 1'-0" TYP CAST IN P LAC E CONCRETE —--—— — — — — —— —•�-- I o I #4 REBAR @ 12" • BOTH DIRECTIONS, I • TYP lo #4 REBAR @ NOSING �I1� MAX Q oQ� LLJ LL FINISH GRADE 0 NORTH 0 5 10 GRAPHIC SCALE MAIN FLOOR FRAMING PLAN NOTES: A. FLOOR FRAMING — MEMBER SIZE AND SPACING PER PLAN. B. SUBFLOOR DECKING TO BE 3/4" T&G PLYWOOD WITH 48/24 SPAN RATING. C. LUMBER IN CONTACT WITH CONCRETE TO BE PRESERVATIVE TREATED WOOD. D. ALL FRAMING HARDWARE TO BE "SIMPSON" OR EQUAL. REQUIREMENTS 1. GLUE AND NAIL SUBFLOOR DECKING TO SLEEPERS. 2. R-10 RIGID INSULATION @ ALL SLEEPER SPACES. 3. PROVIDE SOLID BLOCKING AT ALL BEARING. TAM Design 10040 Sand Point Way NE Seattle, WA 98125 calvint006@gmail.com Peterson Interior Garage Alteration 8410 192nd St SW Edmonds, WA 98026 Permit Set Date: Description: 08/09/21 Permit Intake Project No.: 2150.00 Drawn: RECEIVED Aug 09 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT FRAMING PLAN �C DETAILS Sheet No: A300 DETAIL SCALE: 1-1 /2"=1 ' -0" DETAIL SCALE: 3/4"=1 '-0" WHOLE HOUSE MECHANICAL VENTILATION (M1505.4): EACH DWELLING UNIT SHALL BE EQUIPPED WITH A VENTILATION SYSTEM. THE WHOLE —HOUSE MECHANICAL VENTILATION SYSTEMS SHALL BE DESIGNED IN ACCORDANCE WITH SECTIONS M1505.4.1 THROUGH M1505.4.4. M1505.4.1 SYSTEM DESIGN THE WHOLE —HOUSE VENTILATION SYSTEM SHALL CONSIST OF ONE OR MORE SUPPLY FANS, ONE OR MORE EXHAUST FANS, OR AN ERV/HRV WITH INTEGRAL FANS, ASSOCIATED DUCTS AND CONTROLS. WHOLE —HOUSE MECHANICAL VENTILATION SYSTEM WITH SUPPLY AND EXHAUST FANS PER SECTIONS M1505.4.1.2, M1505.4.1.3, M1505.4.1.4, AND M1505.4.1.5. LOCAL EXHAUST FANS ARE PERMITTED TO SERVE AS PART OF THE WHOLE —HOUSE VENTILATION SYSTEM WHEN PROVIDED WITH THE PROPER CONTROLS PER SECTION M1505.4.2. THE SYSTEMS SHALL BE DESIGNED AND INSTALLED TO EXHAUST AND/OR SUPPLY THE MINIMUM OUTDOOR AIRFLOW RATES PER SECTION M1505.4.3 AS MODIFIED BY THE WHOLE —HOUSE VENTILATION SYSTEM COEFFICIENTS IN SECTION M1504.5.3.1 WHERE APPLICABLE. THE WHOLE —HOUSE VENTILATION SYSTEM SHALL OPERATE CONTINUOUSLY AT THE MINIMUM VENTILATION RATE DETERMINED PER SECTION M1505.4.2 UNLESS CONFIGURED WITH INTERMITTENT OFF CONTROLS PER SECTION M1505.4.3.2. M1505.4.2 SYSTEM CONTROLS 1. THE WHOLE —HOUSE MECHANICAL VENTILATION SYSTEM SHALL BE PROVIDED WITH CONTROLS THAT COMPLY WITH THE FOLLOWING: 2. THE WHOLE —HOUSE VENTILATION SYSTEM SHALL BE CONTROLLED WITH MANUAL SWITCHES, TIMERS OR OTHER MEANS THAT PROVIDE FOR AUTOMATIC OPERATION OF THE VENTILATION SYSTEM THAT ARE READILY ACCESSIBLE BY THE OCCUPANT; WHOLE —HOUSE MECHANICAL VENTILATION SYSTEM SHALL BE PROVIDED WITH CONTROLS THAT ENABLE MANUAL OVERRIDE OFF OF THE SYSTEM BY THE OCCUPANT DURING PERIODS OF POOR OUTDOOR AIR QUALITY. CONTROLS SHALL INCLUDE PERMANENT TEXT OR A SYMBOL INDICATING THEIR FUNCTION. RECOMMENDED CONTROL PERMANENT LABELING TO INCLUDE TEXT SIMILAR TO THE FOLLOWING: "LEAVE ON UNLESS OUTDOOR AIR QUALITY IS VERY POOR." MANUAL CONTROLS SHALL BE READILY ACCESSIBLE BY THE OCCUPANT; 3. WHOLE —HOUSE VENTILATION SYSTEMS SHALL BE CONFIGURED TO OPERATE CONTINUOUSLY EXCEPT WHERE INTERMITTENT OFF CONTROLS AND SIZING ARE PROVIDED PER SECTION M1505.4.3.2. M1505.4.3 MECHANICAL VENTILATION RATE THE WHOLEHOUSE MECHANICAL VENTILATION SYSTEM SHALL PROVIDE OUTDOOR AIR AT A CONTINUOUS RATE AS DETERMINED IN ACCORDANCE WITH TABLE M1505.4.3(1) OR EQUATION 15-1. VENTILATION RATE IN CUBIC FEET PER MINUTE = (0.01 x TOTAL SQUARE FOOT AREA OF HOUSE) + [7.5 x (NUMBER OF BEDROOMS + 1)] BUT NOT LESS THAN 30 CFM FOR EACH DWELLING UNIT. TABLE M1505.4.3(1) CONTINUOUS WHOLE —HOUSE MECHANICAL VENTILATION SYSTEM AIRFLOW RATE REQUIREMENTS DWELLING UNIT FLOOR AREA (SQUARE FEET) NUMBER OF BEDROOMS 0-1 2 3 1 4 5 OR MORE AIRFLOW IN CFM < 500 30 30 35 45 50 501-1,000 30 35 40 50 55 1,001-1,500 30 40 45 55 60 1,501-2,000 35 45 50 60 65 2,001-2,500 40 50 55 65 70 2,501-3,000 45 55 60 70 75 3,001-3,500 50 60 65 75 80 3,501-4,000 55 65 70 80 85 4,001-4,500 60 70 75 85 90 4,501-5,000 65 75 80 90 95 For SI: 1 square foot = 0.0929 m2, 1 cubic foot per minute = 0.0004719 m3/s. TABLE M1505.4.3(2) SYSTEM COEFFICIENT CsYSTEM) SYSTEM TYPE DISTRIBUTED NOT DISTRIBUTED BALANCE 1.0 1.25 NOT BALANCED 1.25 1.5 TABLE M1505.4.3(3) INTERMITTENT WHOLE —HOUSE MECHANICAL VENTILATION RATE FACTORS b RUN—TIME PERCENTAGE IN EACH 50% 66% 75% 100% 4—HOUR SEGMENT FACTOR° 2 1.5 1.3 1.0 a. For ventilation system run time values between those given, the factors are permitted to be determined by interpolation. b. Extrapolation beyond the table is prohibited. M1505.4.4 LOCAL EXHAUST RATES LOCAL EXHAUST SYSTEMS SHALL BE DESIGNED TO HAVE THE CAPACITY TO EXHAUST THE MINIMUM AIRFLOW RATE DETERMINED IN ACCORDANCE WITH TABLE M1505.4.4(1). IF THE LOCAL EXHAUST FAN IS INCLUDED IN THE WHOLE —HOUSE VENTILATION SYSTEM, IN ACCORDANCE WITH SECTION 1505.4.1, THEN THE EXHAUST FAN SHALL BE CONTROLLED TO OPERATE AS SPECIFIED IN SECTION M1505.4.2. TABLE M1505.4.4(1) MINIMUM REQUIRED LOCAL EXHAUST RATES FOR ONE— AND TWO—FAMILY DWELLINGS AREA TO BE EXHAUSTED EXHAUST RATES INTERMITTENT CONTINUOUS KITCHEN 100 CFM 30 CFM BATHROOM — TOILET ROOMS 50 CFM 20 CFM NOTE: REFER TO TABLE M1505.4.4.(2) FOR PRESCRIPTIVE EXHAUST DUCT SIZING. CONIC LANDING AND STEPS u MAIN (E) CONICDRIVEWAY ENTRY MAIN FLOOR CONSTRUCTION PLAN SCALE: 1 /4"=1 '—O" MAIN FLOOR FRAMING PLAN NOTES: MATERIALS A. ALL NEW EXTERIOR WALLS TO BE 2x6 STUDS @ 16" OC. B. ALL EXISTING EXTERIOR WALLS ARE 2x4 STUDS @ 16" OC. C. ALL FRAMING HARDWARE TO BE "SIMPSON" OR EQUAL. D. WALL SHEATHING TO BE 1 /2" PLYWOOD WITH SPAN RATING OF 24/16. E. ALL HDR TO BE DOUGLAS—FIR #2. REQUIREMENTS 1. PROVIDE FIREBLOCKING PER SECTION R602.8. 0 NORTH 0 5 10 GRAPHIC SCALE LEGEND (E) 2x WALL CONSTRUCTION. EXISTING CONSTRUCTION TO BE REMOVED. (E) 2x WALL CONSTRUCTION. FIELD VERIFY THICKNESS AND ADDED FURRING TO MEETING R-21 INSULATION VALUE. 2x6 EXTERIOR WALL CONSTRUCTION (W/ R-21 INSULATION). 2x4 INTERIOR WALL CONSTRUCTION. (E) DOOR TO BE SALVAGED OR REMOVED (E) DOOR TO REMAIN NEW OR RELOCATED DOOR X SMOKE DETECTOR (IRC — SECTION R314) SD X CARBON MONOXIDE DETECTOR (IRC — SECTION R315) CMD EXHAUST FANS: MIN. 50 CFM FOR BATHROOM AND LAUNDRY; MIN. 100 CFM FOR KITCHEN, WITH DIRECT VENT TO EXTERIOR TAM Design 10040 Sand Point Way NE Seattle, WA 98125 calvint006@gmail.com Peterson Interior Garage Alteration 8410 192nd St SW Edmonds, WA 98026 Permit Set Date: Description: 08/09/21 Permit Intake Project No.: 2150.00 Drawn: RECEIVED Aug 09 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT FLOOR PLAN DETAILS Sheet No: (E) INDICATES EXISTING FIXTURE MEA C-11)