Loading...
REVIEWED BLD2022-0298+Calculations+2.24.2022_10.05.23_AM+2700237Basic Deck This tip sheet reflects code requirements of the 2018 International Residential Code (IRC) with Washington State Amendments. Typical Deck This document provides building code information applicable to prescriptive residential wood deck design. You may need to hire a licensed architect or engineer to design a deck where any of the following conditions apply: • The deck serves other than a one- or two-family dwelling building • The deck design includes more than one level + The deck will support a hot tub, spa or other heavy object, including heavy deck covering (such as pavers) The walking surface is more than 14 feet above grade • The deck ledger is attached to house overhangs, bay windows, bricks, stone, or concrete block + The deck is bearing on ground with a slope greater than 1 foot horizontal for every 1 foot vertical The deck is self-supporting (not attached to an exterior wall) See DOW t rar co!mecr," a Joist Hanger Joist Decking Vanly *i'afr"i' dI plaposaa deolrg Joist Overhang 74' maximum ` C See Page 6 Joist Spacing t for Ledger Attachment See Span taao Ard / -,I tdolRK]SGIRr�NH. / r Post 04 min. Up to a- 6 hn1®trt 5,6 iNn. up to I i 1,61wil f :��I.�+pSpan a Non -corrosive metal posUheam connector Note: Guards are Seam Soo span tahla. required when the deck Continuous solid brooking walking surface is more Footing between joists that 30" above � rade. _ s� spnn table and 1ao!irtg scliDdute. Beam Overhang 24' maximum Copyright 2022 All Decks, Inc THESE DRAWINGS ARE COPYRIGHTED MAiERUU- AND MAY NOT BE COPIED OR REDRAWN WITHOUT THE EXPRESSED WRITTEN CONSENT OF ALL DECKS, ii THESE DRAWINGS ARE LIMITED TO A iPROJECT FOR PERSONS NAMED ND ron THE USE AND COMPLETION OF ONE CONSTRUCTICN PROJECT. ANY OTHER USE OR REUSE IS STRICTLY PRDHI RrcED W171 WRITTEN CONSENT BY ALL DECKS, INC. A L L D E (A';"K Z05" 17455 bath Ave NE - Suite 101 <enlmore, LJAshington SSf�28 fnF0ea I ldecics�om .2C6 919 .5016 License No. ALLDEDDB&01:)U Deck Construction Notes • Design loading for decks is based on 60 pounds per square feet (PSF) live load, 10 PSF dead load, and 1500 PSF soil -bearing capacity. • The illustrations and information in this tip Sheet may be used for decks whether or not they require a permit. See Tip Sheet 0 for when a permit is required. • All wood must be pressure -treated or naturally resistant to decay. Treat cuts, holes, and notches with end -cut solution. • Fasteners, hangers, nails, etc., must be stainless steel, hot -dipped galvanized, or as specifically required for the specified wood preservative used. The coating weights for zinc -coated fasteners to be in accordance with ASTM A 153. Provide documentation in the field showing the required fastener protection for the wood chosen for your deck. + You may modify any components of this Tip Sheet using accepted engineering practices. Any modifications must be reviewed prior to permit issuance. All attachments must be per manufacturer's installation instructions. • Visit MyBuildingPermit.com for additional Tip Sheets for stairs, handrails, and notching and boring. 36' minimum high guard with Intermediate rails Attachment of spaced so that a sphere pre -manufactured guardall -- Existing building 4" In diameter cannot syyhall ms tobe deck components pass through (Sae Tip Special blocking details may be LF11ashIng. Sheet 3). required by the reviewer. ee detail 1 on page forledger - Refer table on page See page 8 for guardrail tachment options 3 for Joist Sizes post connection / [Pecking and Spans Secure baliusters with (1) #8d wood screw top & bottom a You spacing Refer to Table on Beam Size and Spans e 3 for recommended \ / Note, for drainage Contractor to field verify adequacy of Knee braces are required If sogd lu bar for ledger distance from grade to top of connection. post exceeds 48". See detall Ir an exit or egress from an page 7 the existing building passes under the For post size and maximum pproposed deck, or If there allowable height, see page 4 is an existing patio under the pproposed deck, 6'-8" minimum clearance must be maintained. Please Indicate openinga in Manufactured post base cast in existing wall in elevation fogting view. - Refer to Table on page 4 for Footing Size 3,O00 psi concrete (no special Inspection required) Finished grade 1"clear Minimum (2) #4 ea. way, 3" clear de th of wiw=z�_ 'to bottom of footing. foctin 12"Footng to bear on gundisturbed earth. The Nelson Deck Evan & Anna Nelson 20509 15th Place W i=dmoni WA SaO2G 425 23,a9847 Standard Deck Framing Details - IRC 2018 BLD2022-0298 RECEIVED Mar 09 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Data January 21t,h 2022 6T6 IRC 1 When using the tables below, interpolation is allowed, extrapolation is not allowed. Sizing of Structural Elements Maximum Deck Joist Span Joist Joist Spacing b inches Joist Back Span Size 12 16 24 4 6 8 10 12 14 16 18 Allowable Joist Span Maximum Cantilever (feet inches) Joist S an feet 2x6 7-11 7-1 5-9 1-0 1-6 NP NP NP NAd'acent P NP NP 2x8 10-5 9-5 7-8 1-0 1-6 2-0 2-1 NP NP NP NP 2x10 13-3 11-6 9-5 1-0 1-6 2-0 2-6 2-8 NP NP NP__ 2x 12 15-5 13-4 10-11 1-0 1-6 2-0 2-6 3-0 3-3 N P NP a. Includes Incising Factor. b. When using composite decking, refer to manufacturer's installation instructions for maximum spacing of joists. c. Spans based on Doug Fir -Larch, Hem Fir and Spruce -Pine -Fir, No. 2 grade, wet service factor. Minimum Beam Size_ Deck Joist Span feet 6 8 10 12 14 16 18 Beam Size c,d,e Maximum Beam Span a,b,d (feet -inches) 4x6 5-2 4-6 4-0 3-5 3-1 2-10 2-7 48 6-11 6-0 5-3 4-7 4-1 3-8 3-5 410 8-5 7-4 6-6 5-10 5-2 4-9 4-5 4x12 9-10 8-6 7-7 6-11 6-4 5-9 5-4 6x6 6-6 5-7 5-0 4-7 _ 4-2 3-9 3-5 6x8 8-8 7-6 6-8 6-1 5-6 5-0 4-7 6x10 10-7 9-2 8-2 7-6 6-11 6-4 5-10 6x12 12-4 10-8 9-7 8-9 8-1 7-7 7-1 a. Spans based on Doug Fir -Larch, Hem Fir ana Spruce-rine-l-Ir, ]Vo. [ graue, wt;L SClvit.:C factor. b. If 2x built up beams to make 4x or 6x beams, they shall be fastened with two rows of 10d (3-inch x 0.128-inch) nails minimum at 16 inches on center along each edge (507.5) c. Beam depth shall be equal to or greater than the depth of intersecting joist for a flush beam connection. d. Beam cantilevers are limited to the adjacent beam's span divided by 4. e. Includes incising factor. :0 Capyright2022 All [:>e;cks, Inc THESE DRAWINGS ARE COPYRIGHTED MATERAL AND MAY NOT BE COPIED OR REDRAWN WITHOUT THE EXPRESSED W RI_EN CONSENT OF ALL DECKS. INC. THESE DRAWINGSARE uAMTED TO A SPECIFIC PROJECT FOR PERSONS NAMED HEREIN AND FOR THE USE AND COMPLETION OF ONE CONSTRUCTION EROJECT, ANY OTHER USE OR RELSE IS STRICTLY PROHIBITED WITHOUT WRITTEN CONSENT BY ALL DECKS, INC. ALLDECKS I-1455 65th Ave NE - Sulte 101 Kenmore, UJ45hington e5025 inPoaa I (decics.com 2J�6 9/9 b916 License No. ALLDEDD560DU Maximum Deck Post Hei ht Tributary Area e _ Post 20 40 60 80 100 120 1 140 160 Size c,d Maximum Deck Post Height a feet -inches 4x4 10-0 10-0 8-7 7-0 5-8 4-1 NP NP 4x6 14-0 13-10 11-1 9-5 8-2 7-3 6-4 5-4 6x6 14-0 14-0 14-0 14-0 14-0 13-3 10-9 6-11 8x8 14-0 1 14-0 14-0 14-0 14-0 14-0 14-0 14-0 a. Measured from the underside of the beam to top oT rooting. b. Based on Doug Fir, Hem Fir and Spruce -Pine -Fir, No. 2 grade, wet service factor. c. Notched deck posts shall be sized to accommodate beam size. d. Includes incising factor. e. Area, in square feet, of deck surface supported by post and footing. Footin Size a Tributary Area b Side of Square Footing (inches) Diameter of a Round Footing inches Thickness inches (inches) 5 7 8 6 _. 20 12 14 6 40 18 20 6 60 21 24 8 80 25 28 9 100 28 31 11 120 30 34 12 140 33 37 13 160 35 1 40 15 a. Footing dimensions shall allow complete Dearing oT the post. b. Area, in square feet, of deck surface supported by post and footings. 12" min. frost depth In allowable soils a Thickness ` per Table Note: Posts must be Width centered on or In tooting per Table The Nelson Deck Evan & Anna Nelson 20509 78th Place ld Edmonds, WA 98026 42 5 2 38 984-1 --- Manufactured post connector 1z° f1" kill a 112" diameter through -bolts in both � 4" gravel directions Note: not screws Typical P.T. post E r Y�ii a Min. 12" of embedment Standard Deck Framing Details - IRC 2018 RECEIVED Mar 09 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT pate January 2 1th, 2= Fraje t 875 IRC 2 EXTER[ORSHt A1IiiNG EXISTING STUD WALL -- Exisling 1x BAND JOIiST OR ENGINEERING phut 80ARD �^ 4t#N I _L T DECK JOIST fW141r t s' MAX LAG SCREWS DR BOLT$ JOIST HANGER Leg screw or gait Stagger fasteners in 2 rows 2" min. 5 112" min. for 2x8 " 5" max. 6 112" min. for 2x1D 7 112" min. for 2x12 3/4" min. Ledger A Distance can be reduced to 211 min. 4 1/2" if lag screws are used or Minimum edge distance for if bolt spacing is reduced to specialized screws. See that of lag screws to attach 2x8 manufacturer's technirai bulletin. ledgers to 2x8 band joists Hold-down or tension device with 1 a€lCi # capacity Flashing 0,ock,toist Detail 1 — Ledger Attachment for Lateral Loads (Knee braces are required on posts greater than 4 feet in height.) Option # 1 Flow sheathing nailing at 6' o,c. (max) to Est with bold -clown. ® Copyright2022 All Decks, Eno THESE DRAWINGS ARE COPYRIGHTED MATERIAL AND MAY NOT BE CDPIc'❑ DR REDRAW N W RHOUT THE EXPRESSED WRITTEN CONSENT OF ALL DECKS, INC. THESE DRAWINGS ARE LIMITED TDA SPECIFIC PROJECT FOR PERSONS NAMED HEREIN AND FOR THE USE AMC COMPLETION OF ONE CONSTRUCTION PROJECTL ANVOTHER USE OR REUSE IS STRICTLYPRISHIRI FED WITHOUT WRITTEN CONSENT BY ALL DECKS, INC, Sheathing Siding Flashing Decking Joists Joist Hangers Treated 2xledger Flow last 750# capacity holddown device at 4 locations evenly distributed along the deck and within 2 ft of each end, install per manufacturer Fully threaded 318" diameter lag screw predrltled with a minimum of 3 in embedment into solid framing. Option # 2 2` min.. Floor joists U Kf " b" " A L L ur" E "0' A 11455 65th Ave NE - Sulu 101 Kenmons, WAshington 98028 infoda Ildecks,com 206 3/3 a5916 License Na_ ALLDEDD860D%� Deck Ledger and Connections Deck Ledger Connection to Band Joist On -Center Spacing of Fasteners inches Joist Span ° (feet) 1/2-inch diameter lag screw with %-inch maximum sheathing b'c'e '/2-inch diameter bolt with '/x-inch maximum sheathing c '/z-inch diameter bolt screw with 1-inch maximum sheathing d 6 T 22 36 35 8 16 31 26 10 _ 13 25 21 12 11 20 17 14 9 17 15 16 8 15 13 _ 18 7 . _ 13� _ 11 a. Ledgers shall be flashed in accordance with Section R703.4 to prevent water from contacting the house band joist. b. The tip of the lag screw shall fully extend beyond the inside face of the band joist. c. Sheathing shall be wood structural panel or solid sawn lumber. d. Sheathing shall be permitted to be wood structural panel, gypsum board, fiberboard, lumber, or foam sheathing. Up to 1/2-inch thickness of stacked washers shall be permitted to substitute for up to 112-inch of allowable sheathing thickness where combined with wood structural panel or lumber sheathing. e. For on -center spacing of specialized fasteners refer to the manufacturer's installation instructions. Placement of Lag Screws and Bolts in Ledgers and Band Joists Minimum End and Edge Distance and Spacing Between Rows Top Edge Bottom Edge Ends Row Spacing Ledger' 2 inches d 3/4 inch 2 inches b 1-5/8 inches b Band joist 3/4 inch 2 Inches e 2 inches h 1-5/8 inches a. Lag screws or bolts must be staggered from the top and bottom along the horizontal run. See figure below. b. Maximum 5 inches. c. For engineered rim joists, the manufacturer's recommendations govern. d. The minimum distance from the bottom row to the top edge of the ledger must be in accordance with figure below. e. 2 inches may be reduced to 3/4-inch when the band joist is directly supported by a mudsill, header, or by double top wall plates. The Nelson Deck Evan & Anna Nelson 20509 15th Place W Edmcnds, WA 9802r. 425 238 9841 Standard Deck Framing Details - IRC 2018 RECEIVED Mar 09 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Mate Jam"ru 211h.2= !'roject eT6 IRC 3 Connections and Fasteners (Ali fasteners, nails, bolts, screws, and connectors must be corrosion resistant.) Type of Connection: Notes: Manufactured Connectors Follow manufacturer's instructions Post to Footing Post base is required Post to Footing (High Winds) Consult with jurisdiction about additional uplift loads where wind exposure is greater than Risk Category B Post to Beam Connector is required Ledger to House Framing See information on Sheet 5 and Sheet 6 Joist to Beam or Girder 3 8d — Toe nailed Blocking or Bridging to Joist 2 10d — Toe nailed at each end Wooden Deck Boards 48d threaded nails OR (2) No. 8 screws Composite Decking Follow manufacturer's instructions Post to Beam Connection with Knee Brace (Knee braces are required on posts greater than 4 feet in height.) .or 1 3 the height of the post, gy whiohever is gfeater Gorrosio n resistant, metal calu'mn cap. Follow manufacturer's installaliori instwrtions, iV Alternate Knee :Brace Detall: W knee brace face nailed Asa. side Df post and bearn with 4-1 rid: nails at each face wind connection ® Copynght2D22 All Decks, Inc THESE DRAWINGS ARE COPYRIGHTED MATERIAL AND MAY NOT BE COPIED OR REDRAWN NIITHOUT THE EXPRESSFD WRITTEN CONSENTCF ALL DECKS, INC THESE DRAWINGS ARE LIMITED TO A SPECIFIC PROJECT FOR PERSONS NA FD HEREIN AND FOR THE USE AND COMPLETION OF ONE CONSTRUCTION PROJECT. ANY OTHER USE OR REUSE IB STRICTLY PROHIBITED WITHDU1 WRITTEN CONSENT BY ALL DECKS, INC. Beam splices must occur over posts with 1-V2" min- nearing Girder team 4 x 4 knee brace (i) 118" dierneterthru-boot or &!2 lard screws with washers, tgp & outtom (typical) Pressure treated wood post Guards $ Attachment Guards are required when the deck is more than 30 inches above grade.) 2x2 Baluster, typical 6'_0" max. spacing ---- ---- 2x6 or 5/4 board ail cap: attach to guard past with (3) #12 by 3" long screws or (3) 16d threaded nails with 0.148 nominal diameter 2x4 top and bottom; attach to guard post with (2) 8d threaded nails or (2) #8 wood screws >_ 2 112" long on inside face �- 4x4 guard post, typical nn Nnt Nntrtt 2 x 8 nominal rim or outside ------------ joist, minimum 2 5/8" diameter Openings shall Attach balusters at top and bottom with through -bolts not allow the (1) #8 wood screw or (2) 8d post -frame and washers passage of a 4" threated nails with 0.135 nominal diameter sphere diameter O.D. galvanized bolt or threaded rod w/ nuts & washers Zf min and F max Min. 1800# tension device 4x4 min. post @ 60" o.c. max., Typ —1 7min Section A 2x8 min. blocking 2"min 2x8 min. deck 2"min joists& rims 2min and 4"max 2"min Note: Use above details for guard canner#ions or provide engineered Arlin. 1800# tension straps design that shows Guards can resist a single concentrated load [] of 200 � applied in any direction at any point along the top and Section B have attachment devices and supporting structure to transfer this load to appropriate structural elements of the building per IBC sec 1607.7.1.1 The Nelson Deck Evan & Anna Nelson 20509 i8th Place LU Edmonds, WA 9802(0 425 238 e84'1 5/s" D.D. galvanized bolt or threaded rod w/ nuts & washers Standard Deck Framing Details - IRC 2018 RECEIVED Mar 09 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT DAie January 21fh, 2=2 Project mr, IRC 4