Loading...
FIR2022-0082_Fire_Alarm_Equipment_Specification_Sheets_8.25.2022_2.12.02_PM_3073123UL LLC CERTIFICATE OF COMPLIANCE COVER PAGE Applicant Subscriber No: 370746-011 Service Center Number: 22 Service Contract No: - ACTIVE LISTINGS CCN File No. Vol. No. CRZM BP10566 1 CPVX BP1790 3 CRZH BP6719 7 UUFX S2684 20 Listed Service From: IRVING, TX Alarm Service Company: Service Center: ADT COMMERCIAL ADT COMMERCIAL 4221 W JOHN CARPENTER FWY 4221 W JOHN CARPENTER FWY IRVING TX 75063-2924 IRVING TX 75063-2924 (L u Applicant ID No: 370746-011 Service Center No: 22 Expires: 01-JAN-2023 CERTIFICATE OF COMPLIANCE THIS IS TO CERTIFY that the Alarm Service Company indicated below is included by Underwriters Laboratories Inc. (UL) in its Product Directories as eligible to use the UL Listing Mark in connection with Certificated Alarm Systems. The only evidence of compliance with UL's requirements is the issuance of a UL Certificate for the Alarm System and the Certificate is current under UL's Certificate Verification Service. This Certificate does not apply in any way to the communication channel between the protected property and any facility that monitors signals from the protected property unless the use of a UL listed or Classified Alarm Transport Company is specified on the Certificate. Listed Service From: IRVING, TX Alarm Service Company: (370746-011) ADT COMMERCIAL 4221 W JOHN CARPENTER FWY IRVING TX 75063-2924 Service Center: (370746-011) ADT COMMERCIAL 4221 W JOHN CARPENTER FWY IRVING TX 75063-2924 The Alarm Service Company is Listed in the following Certificate Service Categories: File - Vol No. CCN Listing Category BP1790-3 CPVX [Burglar Alarm Systems] Central Station BP6719-7 CRZH [Burglar Alarm Systems] National Industrial Security Systems BP10566-1 CRZM Monitoring Stations, National Industrial Security S2684-20 UUFX [Signal and Fire Alarm Equipment and Services] (Protective Signaling Services) Central Station ***THIS CERTIFICATE EXPIRES ON 01-JAN-2023*** "LOOK FOR THE UL ALARM SYSTEM CERTIFICATE" d StarLink APCO INTRODUCTION The StarLink*M SLE-LTEVI-CFBPS, SLE-LTEAI-CFBPS, SLE-LTEVI- CFB and SLE-LTEAI-CFB Dual -Path Commercial / Residential Fire alarm capture radio IP communicators are fully supervised, wireless digital two-way subscriber units. All models are com- patible with most 12/24VDC alarm control panels (always ad- here to the documentation provided by the control panel man- ufacturer). These communicators are for use as the primary means of communication with the central station and do not have backup mode capability. See W12140 for programming information. The LTE Series radios use data -capture technology that cap- tures the alarm report from the control panel and transmits the alarm signals to the Network Operations Center; the alarm sig- nals are then forwarded to ANY central station via Contact ID or 4/2 central station formats. The radios can also report to a Sur -Gard System II central station receiver via TCP/IP using standard line security. The Network Operations Center reports a trouble signal in the event that the network does not receive the expected supervision signal from the wireless communica- tor. FIRE ALARM COMPATIBILITY StarLink LTE Series models are compatible with any FACP STARLINK RADIO REPORTING PATH The diagram below shows the transmission path of a signal from the StarLink radio to the central station. 1. Signal from a Control Panel. 2. StarLink radio receives the signal transmission (from the TIP an RING wires); sends RF signal through the GPRS network operator. 3. Network Operator, part of the vendor system, a section of the cellular spectrum. 4. Network Operations Center, receives / routes data. 5. Central Station. ':DATA StarLink Radio 2 (3) FACP (1) Network Operator IIIIIII ( 5 ��� (4) CENTRAL ) STATION StarLink Network Operations Center SLE-LTEVI-CFBPS & SLE-LTEAI-CFBPS SLE-LTEVI-CFB & SLE-LTEAI-CFB Commercial / Residential Fire Series Dual Path Alarm Communicators Submittal Data Sheet SLE-LTEVI-CFBPS & SLE-LTEAI-CFBPS: Commercial / Residential Fire LTE Radio -TCP/IP Communicators in red metal housing with SLE-ULPS-R power supply and 16.5V / 20VA transformer mounted inside housing SLE-LTEVI-CFB & SLE-LTEAI- CFB: Commercial / Residential Fire LTE Radio -TCP/IP Communicators in red metal housing. Powered direct- ly from control panel (no power supply, no transformer, rated nomi- nal 12/24VDC input) equipped with a DACT that must transmit central station reports in Contact ID or 4/2 central station formats. The control panel may also trigger communication events through the use of FACP dry contacts connecting the (3) radio inputs, capable of trans- mitting (4) distinct alarm and trouble event reports to the central station. The following features are included: • Power limited output to the StarLink radio PC board 12V input terminals • Battery connection red and black flying leads • Monitored battery charging and Active battery test circuits • Requires a sealed lead acid min 4AH / max 7AH battery for minimum 24-hour standby time (max charge current 200mA). • Trouble relay output (C, N/O and N/C terminals) to wire to a panel zone dedicated to "GSM Trouble" (dry contacts). Re- move jumper " J2" isolate relay OUT1 common from ground • Green AC ON LED visible from the exterior housing • Yellow TROUBLE LED on PC board. Flashes signify: One flash: AC fail / brownout (2 hour delay) Two flashes: Low battery Three flashes: Charging circuit trouble Four flashes: StarLink radio trouble The housing -mounted transformer (when provided) is mounted inside its own housing compartment with a replaceable UL Listed .5A fast blow primary fuse. 120VAC connections are to be made by a licensed electrician using suitable connectors, in ac- cordance with N.E.C. and local code requirements. ADDITIONAL COMPONENTS In addition to the models listed above, the following accessories NAPCO Security Technologies, Inc., 333 Bayview Ave, Amityville, NY 11701 (800) 645-9445; Fax (631) 789-9292 A755A 10/19 13 are available and permitted by UL: SLE-WIFI-MODULE - Allows your Napco StarLinkrM device to connect to the Internet by means of a wireless (Wi-Fi) link, eliminating a wired Ethernet cable connection. Note: 7AH battery required when using the SLE-WIFI-MODULE. For more information, see WI2191. SLE-DLCBL - Download Cable, 6 feet SLE-ANTEXT30 - Extended antenna with 30 feet of cable SLE-ANTEXT50 - Extended antenna with 50 feet of cable SLE-ANTEXT75 - Extended antenna with 75 feet of cable SLE-ANTEXT100 - Extended antenna with 100 feet of cable (Any suitable external cellular antenna is permitted by UL). Always follow the manufacturer's installation instructions. GEM-Tamperkit - Tamper switches and screws to protect metal housing. SPECIFICATIONS The following specifications apply to all StarLink radio models unless otherwise stated: Electrical Ratings for 120VAC, 60Hz For Models with Power Supply (SLE-LTEVI-CFBPS & SLE-LTEAI-CFBPS) • Input Voltage: 120VAC nominal • Input Current: 200mA maximum • Maximum Charging Current: 200mA Electrical Ratings for +12V / 24V For Models without Power Supply (SLE-LTEVI-CFB & SLE-LTEAI-CFB) • Input Voltage: 10-25VDC regulated (power -limited out- put from Listed control panel). • Input Current: 10VDC standby: 162mA 12VDC standby: 125mA 15VDC standby: 110mA 24VDC standby: 100mA (Commercial Fire models) 25VDC standby: 100mA (Commercial Fire models) Wi-Fi Module: (Optional) Add 40mA to the above. (With peak RF transmission current of 300mA). Electrical Ratings for the IN 1 Fire Input: • Input Voltage: 9-25VDC. • Maximum Input Current: Up to 2mA from FACP NAC cir- cuit Electrical Ratings for IN 2, IN 3, IN 4, and IN 5: (Inputs IN 2, IN 3, IN 4, and IN 5 are Class B) • Maximum Loop Voltage: 25VDC. • Maximum Loop Current: 1.2mA • End of Line Resistor (EOLR) Value: 10K (2 req'd) Electrical Ratings for PGM3 Output: • Open Collector Output: Maximum Voltage 3V when ac- tive; 25V maximum when not active. • Maximum PGM Sink Current: 50mA (up to 15VDC), 25mA (15.1VDC - 25VDC) Physical (W x H x D) • Metal Housing: 11% x 9% x 3%" (29.2 x 24.1 x 8.9cm) • Mounting: Metal housing includes two keyhole slots for wall mounting (see measurements in WI2327) Environmental • Operating Temperature: 0°C - 49°C (327-120°F) • Humidity: Maximum 93% Non -Condensing • Indoor / dry location use only NOTICE TO AUTHORITIES HAVING JURISDICTION, USERS, INSTALLERS, DEALERS, AND OTHER AFFECTED PARTIES FIRE PROGRAMMING OPTION PERMITTED IN AVAILABLE SETTINGS REQUIRED UL 864 SETTINGS UL864? (Y/N) Unattended Remote Downloading No Enable / Disable Disabled (Jumper 1 installed). Also required for Commercial installations. IN2, IN3, IN4 and IN5 Unsupervised Yes Supervised / Unsupervised Unsupervised using conduit within 20 feet of FACP (default). If not using conduit, install Jumpers 4 and 5 and EOL Resistors. 200 seconds, 5 minutes, 6 200 seconds, 5 minutes, 60 minutes. 6 Hours permitted in Commercial 7 Day Supervision, Radio to NOC No minutes, 60 minutes, 6 Fire UL 864 with Dual Path enabled. hours, 7 days Trouble on Radio or IP Path Yes Either Path or Both Paths Either Path (annunciation and report of trouble) (Annunciate /Report) Wi-Fi Module Yes Enable / Disable May be enabled as a primary reporting path for Fire 14