Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BLD2022-1165_Site_Plan_8.31.2022_11.05.03_AM_3083071
CONSSLING SULTING Scott E. Wyssling, PE Jon P. Ward, SE, PE Gregory T. Elvestad, PE August 22, 2022 Revolotion Solar 9981 West 190th Street Unit K, Mokena, IL 76 North Meadowbrook Drive Alpine, UT 84004 office (201) 874-3483 swyssling@wysslingconsulting.com Re: Engineering Services Brown Residence 21412 96th Avenue West, Edmonds, WA 10.000 kW System To Whom It May Concern: We have received information regarding solar panel installation on the roof of the above referenced structure. Our evaluation of the structure is to verify the existing capacity of the roof system and its ability to support the additional loads imposed by the proposed solar system. A. Site Assessment Information 1. Site visit documentation identifying attic information including size and spacing of framing for the existing roof structure. 2. Design drawings of the proposed system including a site plan, roof plan and connection details for the solar panels. This information will be utilized for approval and construction of the proposed system. B. Description of Structure: Roof Framing: Prefabricated wood trusses at 24" on center. All truss members are constructed of 2x4 dimensional lumber. Roof Material: Composite Asphalt Shingles Roof Slope: 20 degrees Attic Access: Accessible Foundation: Permanent C. Loading Criteria Used • Dead Load o Existing Roofing and framing = 7 psf o New Solar Panels and Racking = 3 psf o TOTAL = 10 PSF • Live Load = 20 psf (reducible) — 0 psf at locations of solar panels • Ground Snow Load = 20 psf • Wind Load based on ASCE 7-16 o Ultimate Wind Speed = 97 mph (based on Risk Category II) o Exposure Category C Analysis performed of the existing roof structure utilizing the above loading criteria is in accordance with the 2018 Washington State Residential Code (2018 /RC), including provisions allowing existing structures to not require strengthening if the new loads do not exceed existing design loads by 105% for gravity elements and 110% for seismic elements. This analysis indicates that the existing framing will support the additional panel loading without damage, if installed correctly. Page 2 of 2 D. Solar Panel Anchorage 1. The solar panels shall be mounted in accordance with the most recent Sunmodo installation manual. If during solar panel installation, the roof framing members appear unstable or deflect non - uniformly, our office should be notified before proceeding with the installation. 2. The maximum allowable withdrawal force for a 5/16" lag screw is 235 Ibs per inch of penetration as identified in the National Design Standards (NDS) of timber construction specifications. Based on a minimum penetration depth of 2'/2", the allowable capacity per connection is greater than the design withdrawal force (demand). Considering the variable factors for the existing roof framing and installation tolerances, the connection using one 5/16" diameter lag screw with a minimum of 2'/2" embedment will be adequate and will include a sufficient factor of safety. 3. Considering the wind speed, roof slopes, size and spacing of framing members, and condition of the roof, the panel supports shall be placed no greater than 48" on center. 4. Panel supports connections shall be staggered to distribute load to adjacent framing members. Based on the above evaluation, this office certifies that with the racking and mounting specified, the existing roof system will adequately support the additional loading imposed by the solar system. This evaluation is in conformance with the Washington State Residential Code, current industry standards, and is based on information supplied to us at the time of this report. Should you have any questions regarding the above or if you require further information do not hesitate to contact me. V truly yours, Scott E. Wyssli , PE Washington License 111163 ib 20111163 E` �GISTBR� Ss,O N A L SN Signed 8/22/2022 �YSSLING CONSULTING GENERAL NOTES 1. INSTALLATION OF SOLAR PHOTOVOLTAIC SYSTEM SHALL BE IN ACCORDANCE WITH NEC ARTICLE 690, AND ALL OTHER APPLICABLE NEC CODES WHERE NOTED OR EXISTING 2. PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110 3. ALL WIRES, INCLUDING THE GROUNDING ELECTRODE CONDUCTOR SHALL BE PROTECTED FROM PHYSICAL DAMAGE IN ACCORDANCE WITH NEC ARTICLE 250 4. THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE; THIS SYSTEM IS UTILITY INTERACTIVE PER UL 1741 AND DOES NOT INCLUDE STORAGE BATTERIES OR OTHER ALTERNATIVE STORAGE SOURCES 5. ALL DC WIRES SHALL BE SIZED ACCORDING TO [NEC 690.81 6. DC CONDUCTORS SHALL BE WITHIN PROTECTED RACEWAYS IN ACCORDANCE WITH [NEC 690.311 7. ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL JURISDICTIONAL BUILDING CODE PHOTOVOLTAIC SYSTEM SPECIFICATIONS EQUIPMENT: AC System Size: 7.6 kW AC DC SYSTEM SIZE: 10.00 kW DC (25) HANWHA Q.PEAK DUO L-G5.2 400 PV Modules (1) SOLAREDGE SE760OH-US (240V) Inverter(s) (25) SOLAREDGE P400 Optimizers RACKING: NANOMOUNT - 48" O.C. APPLICABLE GOVERNING CODES SITE SPECIFICATIONS Revolution Energy Systems Inc. 9981 West 190th St Unit K Mokena IL 60448 T: 708-995-1643 2018 IRC 2018 UPC ZONING: RESIDENTIAL DRAWN BY: V.MIRAFLOR 20181MC 20181PMC DATE: 20181FGC 20181EBC 8/19/2022 COVER PAGE - PV01 0 6 PROPERTY LINE-90'-0" 0 0 0 O 0 o E E E 0 Ll O 1B 10 1 PROPERTY LINE-90'-0" 214TH PLACE SW 0 Ww Z Z J W � Q LU 0- (.0 01 al DRIVEWAY EQUIPMENT LEGEND: UTILITY METER Ac VISAC IDISCONNNECTLE, LABELED ENV INVERTER sub SUB PANEL F-7 METER SOCKET MSP MAIN SERVICE PANEL Pv (FOR UTILITY PV METER) F] COMBINER BOX R LOAD CENTER ARRAY DETAILS: MOUNTING PLANE: AZIMUTH: TILT: MP1 900 200 CLOSE UP OF HOME 0 ❑ 0 0 0 0 o MSP a I E �I a i 0 B JB Fs D SERVICE DISCONNECT —] PV MODULES MP1 VISIBLE, LOCKAB FIRE ACCESS PATHWAY (T TYP) LABELED AC DISCON BAIT BATTERY(IES) JB JUNCTION BOX PROPERTY LINE LOCATED WITHIN OF UTILITY METE so It'll 1 Revolution Energy Systems Inc. 9981 West 190th St Unit K Mokena IL 60448 T: 708-995-1643 SITE INFORMATION LESLIE BROWN 21412 96TH AVENUE W EDMONDS, WA, 98020 AC System Size: 7.6 kW AC DC System Size: 10.00 kW DC Lat, 47.8047240 Long,-122.3618928 (25) HANWHA Q.PEAK DUO L-G5.2 400 PV Modules (1) SOLAREDGE SE760OH-US (240V) Inverter(s) (25) SOLAREDGE P400 Optirrjkers SNOHOMISH COUNTY PUBLICYTILITI( DI,-TRICT GO' s h ' P� 20111169 8Q�3TBA�9 Signed 8/22/2022 LE, DRAWN BY: V.MIRAFLOR N ECT DATE: 10' 8/19/2022 R SITE PLAN - PV02 N INV AC PV M T TYP 0 0 N o O MSP 5 L A R Revolution Energy Systems Inc. 9981 West 190th St Unit K Mokena IL 60448 T: 708-995-1643 SITE INFORMATION LESLIE BROWN 21412 96TH AVENUE W EDMONDS, WA, 98020 AC System Size: 7.6 kW AC DC System Size: 10.00 kW DC Lat, 47.8047240 Long,-122.3618928 (25) HANWHA Q.PEAK DUO L-G5.2 400 PV Modules (1) SOLAREDGE SE760OH-US (240V) Inverter(s) (25) SOLAREDGE P400 Optim' rs LSNOIHOMISH COUNTY PUBLIC( I'ILIT, DI;TRICT Go s y �p 20111163 ty � �QISTBReO O JB JB �— T TYP EQUIPMENT INFORMATION: ROOF INFO: PHOTOVOLTAIC ARRAY STRUCTURAL CRITERIA: pIYA L Qr1G� RAIL MANUFACTURER: SUNMODO ROOF TYPE: COMP. SHINGLE PV MODULE COUNT: 25 RAIL PART NUMBER: SMR ROOF FRAMING: MANUFACTURED TRUSS ARRAY AREA: MODULE COUNT * 21.69 ft2 = 542.25 Signed 8/22/2022 ATTACHMENTS NANOMOUNT RAFTER/TOP CHORD SIZE: 2" X 4" ROOF AREA: 2176.00 ft2 ATTACHMENT CITY: 50 RAFTER/TOP CHORD SPACING: 24" PERCENT OF ROOF COVERED: 25% DRAWN BY: V.MIRAFLOR SPLICE CITY: 6 ATTACHMENT SPACING: 48" ARRAY WEIGHT: MODULE COUNT * 52 Ibs = 1300 Ibs DATE: MIDCLAMP CITY: 40 POINT LOAD: ARRAY LBS/ATTACHMENTS = 26.00 8/19/2022 ROOF ATTACHMENTS - PV03 ENDCLAMP CITY: 20 DISTRIBUTED LOAD: (Ibs/ft2) (ARRAY) WEIGHT/AREA = 2.4 Ibs/ft2 SHARED RAIL END CLAMP PV MODULE RAIL �� END CLAMP DETAILS Material: Aluminum Finish: Black Powder Coating I r - aan i I i�u Material: EPDM + Stainless Steel 9KLU KA1L 15UIVUINU 1 CLAMP / 1 PV MODULE �� MID CLAMP DETAILS R4 nm q r nw sv Material: Stainless Steel Finish: Clear DETAIL, MOUNTING AND FLASHING 1'-8" MAX. RAIL RAIL 48" MAX SPAN NANO MOUNT 2'-8" MIN - 3'-10" MAX (E) RAFTER/TOP CHORD FRONT VIEW 10" MIN - 7 1'-4" MAX / SIDE VIEW PV MODULE RAIL i i 2'-8" MIN - 3'-10" MAX k? (E) RAFTER/TOP CHORDS 10" MIN - 1'-4" MAX EQUIPMENT INFORMATION: ROOF INFO: PHOTOVOLTAIC ARRAY STRUCTURAL CRITERIA: RAIL MANUFACTURER: SUNMODO ROOF TYPE: COMP. SHINGLE PV MODULE COUNT: 25 RAIL PART NUMBER: SMR ROOF FRAMING: MANUFACTURED TRUSS ARRAY AREA: MODULE COUNT * 21.69 ft2 = 542.25 ATTACHMENTS NANOMOUNT RAFTER/TOP CHORD SIZE: 2" X 4" ROOF AREA: 2176.00 ft2 ATTACHMENT CITY: 50 RAFTER/TOP CHORD SPACING: 24" PERCENT OF ROOF COVERED: 25% SPLICE CITY: 6 ATTACHMENT SPACING: 48" ARRAY WEIGHT: MODULE COUNT * 52 Ibs = 1300 Ibs MIDCLAMP CITY: 40 POINT LOAD: ARRAY LBS/ATTACHMENTS = 26.00 ENDCLAMP CITY: 20 DISTRIBUTED LOAD: (Ibs/ft2) (ARRAY) WEIGHT/AREA = 2.4 Ibs/ft2 Revolution Energy Systems Inc. 9981 West 190th St Unit K Mokena IL 60448 T: 708-995-1643 SITE INFORMATION LESLIE BROWN 21412 96TH AVENUE W EDMONDS, WA, 98020 AC System Size: 7.6 kW AC DC System Size: 10.00 kW DC Lat, 47.8047240 Long,-122.3618928 (25) HANWHA Q.PEAK DUO L-G5.2 400 PV Modules (1) SOLAREDGE SE760OH-US (240V) Inverter(s) (25) SOLAREDGE P400 Optimizers SNOHOMISH COUNTY PUBLIC UTILjY DISTRICT 20111163 ?1ST?dRe 5—NAL Signed 8/22/2022 J DRAWN BY: V.MIRAFLOR DATE: 8/19/2022 MOUNTING DETAIL - PV04 HANWHA Q.PEAK DUO L-G5.2 400 Specs POWER MAX (PMAX): 40OW OPEN CIRCUIT VOLTAGE (VOC): 49V MAX POWER -POINT CURRENT (IMP): 9.75A MAX POWER -POINT VOLTAGE (VMP): 41.04V SHORT CIRCUIT CURRENT (ISC): 10.24A SERIES FUSE RATING: 20A STRING (1): 15.0 A DC 13 MODULES SOLAREDGE SE760OH-US (240V) Specs MAX INPUT VOLTAGE: 480 V MAX INPUT CURRENT: 20 A NOMINAL DC INPUT VOLTAGE: 400 V MAXIMUM OUTPUT POWER: 7600 W NOM. OUTPUT VOLTAGE: 240 V MAX OUTPUT CURRENT: 32 A 1-Phase, 60 HZ, UL 1741 Listed Equipment Schedule TYPE: CITY: DESCRIPTION: RATING: MODULES: (25) HANWHA Q.PEAK DUO L-G5.2 400 400 W INVERTERS: (1) SOLAREDGE SE760OH-US (240V) 7600 W AC DISCONNECTS: (1) PV AC Disconnect, 240V, 2-Pole 60 A DC OPTIMIZERS: (25) SOLAREDGE P400 15 Adc SOLAREDGE SE760OH-US(24OV) -- — — — — —— — -- UL 1741 COMPLIANT INTEGRATED RAPID SHUTDOWN DC DISCONNECT STRING (2): 15.0 A DC 1 0 o X 12 MODULES E o ------------ -- ---- ---- AC J-BOX — —LGNDr — — — Conduit & Conductor Schedule TAG CITY WIRE GAUGE DESCRIPTION CONDUIT SIZE (2) 10 AWG (90°C) PV-WIRE, USE-2, COPPER (L1, L2) 1 (1) 6AWG (90-C) THWN-2COPPER -(GROUND) N/A -FREE AIR 2 (4) 10 AWG (90°C) THHN/THWN-2, COPPER - (Ll, L2) 3/4" EMT (1) 10AWG (90°C) THWN-2COPPER -(GROUND) 3 (3) 8 AWG (90°C) THHN/THWN-2, COPPER - (L1, L2, NEUTRAL) 3/4" EMT (1) 8AWG (90°C) THWN-2COPPER -(GROUND) (3) 6 AWG (75°C) THHN/THWN-2, COPPER - (L1, L2, NEUTRAL) 4 (1) 6AWG (75°C) THWN-2COPPER -(GROUND) 3/4" RMC/IMC PV AC DISCONNECT 60A VISIBLE, LOCKABLE, UTILITY PV PRODUCTION LABELED, OPEN METER BASE 240V, 2-POLE LINE SIDE WITH 40A FUSES r F LOAD SIDE (E) 200A MAIN SERVICE PANEL (E) 20OA-2 (E) LOADS N F -1 L �/ LTL I (E) GROUNDING ELECTRODE —I— LINE SIDE TAP USING INSULATION PEIRCING 705.12(A) I I I 120/240 VAC TO UTILITY GRID (E) UTILITY METER VISIBLE, LOCKABLE LABELED AC DISCONN LOCATED WITHIN 1 OF UTILITY METE i Revolution Energy Systems Inc. 9981 West 190th St Unit K Mokena IL 60448 T: 708-995-1643 SITE INFORMATION LESLIE BROWN 21412 96TH AVENUE W EDMONDS, WA, 98020 AC System Size: 7.6 kW AC DC System Size: 10.00 kW DC Lat, 47.8047240 Long,-122.3618928 (25) HANWHA Q.PEAK DUO L-G5.2 400 PV Modules (1) SOLAREDGE SE760OH-US (240V) Inverter(s) (25) SOLAREDGE P400 Optimizers SNOHOMISH COUNTY PUBLIC UTILITY DISTRICT I � DRAWN BY: V.MIRAFLOR E CT DATE: 01 8/19/2022 R LINE DIAGRAM - PV05 STRING CALCULATIONS SOLAREDGE SE760OH-US (240V) STRING #1 STRING #2 OPTIMIZER MAX OUTPUT CURRENT 15A 15A OPTIMIZERS IN SERIES: 13 12 NOMINAL STRING VOLTAGE: 400V 400V ARRAY OPERATING CURRENT: 13A 12A ARRAY DC POWER: 10000W TOTAL MAX AC CURRENT: 32A NUMBER OF CURRENT CARRYING CONDUCTORS PERCENT OF VALUES 4-6 .80 7-9 .70 10-20 .50 SYSTEM OCPD CALCULATIONS INVERTER MODEL(S): SOLAREDGE SE760OH-US (240V) # OF INVERTER(S): 1 MAX OUTPUT CURRENT: 32A (# OF INVERTERS) X (MAX OUTPUT CURRENT) X 125% <= OCPD RATING (1 X 32A X 1.25) = 39.58A <= 40A, OK PV LOAD CALCULATIONS: SUPPLY SIDE TIE-IN FEEDER WIRE RATING: 200A ALLOWABLE SOLAR CALCULATION (FEEDER RATING - 1.25) 160.000OA (FEEDER WIRES ALLOWABLE SOLAR) 160.000OA (AVAILABLE FOR PV) Conduit & Conductor Schedule TAG CITY WIRE GAUGE DESCRIPTION CONDUIT SIZE CONDUCTOR RATING CONDUCTOR TEMP. RATE AMBIENTTEMP TEMP. DERATE # OF CONDUCTORS DERATE CONDUCTOR RATING W/DERATES CONDUIT FILL 1 (2) 10 AWG PV-WIRE, USE-2, COPPER (L1, L2) N/A - FREE AIR 40A 900C 26°C 1.0 N/A - FREE AIR 40.OA N/A - FREE AIR (1) 6 AWG THWN-2 COPPER- (GROUND) 2 (4) 10 AWG THHN/THWN-2, COPPER - (L1, L2) 3/4" EMT 40A 90°C 26°C 1.0 .80 32.OA 19.09% (1) 10 AWG THWN-2 COPPER - (GROUND) 3 (3) 8 AWG THHN/THWN-2, COPPER - (L1, L2, NEUTRAL) 3/4" EMT 55A 90°C 26°C 1.0 1.0 55.OA 26.73% (1) 8 AWG THWN-2 COPPER - (GROUND) 4 (3) 6 AWG THHN/THWN-2, COPPER - (L1, L2, NEUTRAL) 3/4" RMC/IMC 65A 75°C 26°C 1.0 1.0 65.OA 35.49% (1) 6 AWG THWN-2 COPPER - (GROUND) GROUNDING & GENERAL NOTES: 1. PV INVERTER IS UNGROUNDED, TRANSFORMER -LESS TYPE. 2. DC GEC AND AC EGC TO BE SPLICED TO EXISTING ELECTRODE 3. ANY EXISTING WIRING INVOLVED WITH PV SYSTEM CONNECTION THAT IS FOUND TO BE INADEQUATE PER CODE SHALL BE CORRECTED PRIOR TO FINAL INSPECTION. 4. JUNCTION BOX QUANTITIES, AND PLACEMENT SUBJECT TO CHANGE IN THE FIELD - JUNCTION BOXES DEPICTED ON ELECTRICAL DIAGRAM REPRESENT WIRE TYPE TRANSITIONS. 5. AC DISCONNECT NOTED IN EQUIPMENT SCHEDULE OPTIONAL IF OTHER AC DISCONNECTING MEANS IS LOCATED WITHIN 10' OF SERVICE DISCONNECT. INTERCONNECTION NOTES: 1. INTERCONNECTION SIZING, LIMITATIONS AND COMPLIANCE DETERMINED IN ACCORDANCE WITH [NEC 705.12], AND [NEC 690.64]. 2. GROUND FAULT PROTECTION IN ACCORDANCE WITH [NEC 215.9], [NEC 230.95] AND [NEC 690.5] 3. ALL EQUIPMENT TO BE RATED FOR BACKFEEDING. 4. PV BREAKER TO BE POSITIONED AT THE OPPOSITE END OF THE BUSBAR RELATIVE TO THE MAIN BREAKER. DISCONNECT NOTES 1. DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS OPENED THE CONDUCTORS REMAINING LIVE ARE CONNECTED TO THE TERMINALS MARKED "LINE SIDE" (TYPICALLY THE UPPER TERMINALS) 2. AC DISCONNECT MUST BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE LOCKABLE, AND BE A VISIBLE -BREAK SWITCH S L A R Revolution Energy Systems Inc. 9981 West 190th St Unit K Mokena IL 60448 T: 708-995-1643 SITE INFORMATION LESLIE BROWN 21412 96TH AVENUE W EDMONDS, WA, 98020 AC System Size: 7.6 kW AC DC System Size: 10.00 kW DC Lat, 47.8047240 Long,-122.3618928 (25) HANWHA Q.PEAK DUO L-G5.2 400 PV Modules (1) SOLAREDGE SE760OH-US (240V) Inverter(s) (25) SOLAREDGE P400 Optimizers LSNOHOMISH COUNTY PUBLIC UTILITY DISTRICT DRAWN BY: V.MIRAFLOR DATE: 8/19/2022 ELECTRICAL CALCS - PV06 ! WARNING ELECTRIC SHOCK HAZARD TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION /!� WARNING THIS EQUIPMENT IS FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES, EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE, SHALL NOT EXCEED AMPACITY OF BUSBAR. i WARNING INVERTER OUTPUT CONNECTION DO NOT RECOLCATE THIS OVERCURRENT DEVICE I A! WARNING DUAL POWER SUPPLY SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM LABELING NOTES: LABEL 1 FOR PV DISCONNECTING MEANS WHERE THE LINE AND LOAD TERMINALS MAY BE ENERGIZED IN THE OPEN POSITION. [NEC 690.13(B)] LABEL 2 PLACED ADJACENTTO THE BACK -FED BREAKER FROM THE INVERTER IF TIE IN CONSISTS OF LOAD SIDE CONNECTION TO BUSBAR. [NEC 705.12(13)(2)(3)(b)] LABEL 3 PLACED ADJACENTTO THE BACK -FED BREAKER FROM THE INVERTER IF TIE IN CONSISTS OF LOAD SIDE CONNECTION TO BUSBAR. [NEC 705.12(13)(2)(3)(c)] LABEL 4 EQUIPMENT CONTAINING OVERCURRENT DEVICES IN CIRCUITS SUPPLYING POWER TO A BUSBAR OR CONDUCTOR SUPPLIED FROM MULTIPLE SOURCES SHALL BE MARKED TO MAIN SERVICE PANEL INDICATE THE PRESENCE OF ALL SOURCES [NEC 705.12(B)(3)] LABELS AT POINT OF INTERCONNECTION, MARKED AT AC DISCONNECTING MEANS. [NEC 690.54, NEC 690.13 (B)] 1. LABELS CALLED OUT ACCORDING TO ALL COMMON CONFIGURATIONS. ELECTRICIAN TO DETERMINE EXACT REQUIREMENTS IN THE FIELD PER CURRENT NEC AND LOCAL CODES AND MAKE APPROPRIATE ADJUSTMENTS. 2. LABELING REQUIREMENTS BASED ON THE 2017 NATIONAL ELECTRIC CODE, OSHA STANDARD 19010.145, ANSI Z535. 3. MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. 4. LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED [NEC 110.21(B)(3)] 5. LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8", WHITE ON RED BACKGROUND; REFLECTIVE, AND PERMANENTLY AFFIXED [IFC 605.11.1.11 SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN so nRe ecTRic SWICH TO THE "OFF" PVPaNe�s POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN ARRAY TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN I CONDUCTORS OUTSIDE THE ARRAY. CONDUCTORS WITHIN THE ARRAY REMAIN ENERGIZED IN SUNLIGHT LABEL 6 AT DIRECT -CURRENT EXPOSED RACEWAYS, CABLE TRAYS, COVERS AND ENCLOSURES OF JUNCTION BOXES, AND OTHER WIRING METHODS; SPACED AT MAXIMUM 10FT SECTION OR WHERE SEPARATED BY ENCLOSURES, WALLS, PARTITIONS, CEILINGS, OR FLOORS. [NEC 690.31(G)(3&4)] LABEL 7 FOR PV SYSTEMS THAT SHUT DOWN THE ARRAY AND CONDUCTORS LEAVING THE ARRAY: SIGN TO BE LOCATED ON OR NO MORE THAN 3 FT AWAY FROM SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED AND SHALL INDICATE THE LOCATION OF ALL IDENTIFIED RAPID SHUTDOWN SWITCHES IF NOT AT THE SAME LOCATION. [NEC 690.56(C)(1)(A)] LABEL 8 FOR PV SYSTEMS THAT ONLY SHUT DOWN CONDUCTORS LEAVING THE ARRAY: SIGN TO BE LOCATED ON OR NO MORE THAN 3 FT AWAY FROM SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED AND SHALL INDICATE THE LOCATION OF ALL IDENTIFIED RAPID SHUTDOWN SWITCHES IF NOT AT THE SAME LOCATION. [NEC 690.56(C)(1)(b)] LABEL 9 SIGN LOCATED AT RAPID SHUT DOWN DISCONNECT SWITCH [NEC 690.56(C)(3)]. Ol O2 OO4 LABELING DIAGRAM: EXISTING SUB PANEL PV COMBINER (IF WHERE POINT OF SUBPANEL- INTERCONNECTION IF USED TO COMBINE INVERTER (S) IS MADE) AC DISCONNECT PV OUTPUT CIRCUITS °❑° 0 0 0 0 O 77DCI (ONLY IF PV INTERCONNECTION (ONLY IF PV INTERCONNECTION ❑ O O CONSISTS OF LOAD CONSISTS OF LOAD SIDE BREAKER) SIDE BREAKER) INTEGRATED DC DISCONNECT 6 JUNCTION BOX OR COMBINER BOX 06 *ELECTRICAL DIAGRAM SHOWN ABOVE IS FOR LABELING PURPOSES ONLY. NOT AN ACTUAL REPRESENATION OF EQUIPMENT AND CONNECTIONS TO BE INSTALLED. LABEL LOCATIONS PRESENTED MAY VERY DEPENDING ON TYPE OF INTERCONNECTION METHOD AND LOCATION PRESENTED ON THE ELECTRICAL DIAGRAM PAGE. Revolution Energy Systems Inc. 9981 West 190th St Unit K Mokena IL 60448 T: 708-995-1643 SITE INFORMATION LESLIE BROWN 21412 96TH AVENUE W EDMONDS, WA, 98020 AC System Size: 7.6 kW AC DC System Size: 10.00 kW DC Lat, 47.8047240 Long,-122.3618928 (25) HANWHA Q.PEAK DUO L-G5.2 400 PV Modules (1) SOLAREDGE SE760OH-US (240V) Inverter(s) (25) SOLAREDGE P400 Optimizers SNOHOMISH COUNTY PUBLIC UTILITY DISTRICT DRAWN BY: V.MIRAFLOR DATE: 8/19/2022 LABELS - PV07 CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM ROOF MOUNTED SOLAR ARRAYS WITH SAFETY DISCONNECTS AS SHOWN: N MAIN DISTRIBUTION UTILITY DISCONNECT INVERTER & RAPID SHUTDOWN DC DISCONNECT SWITCH lw AC DISCONNECT AC UTILITY METER M PV ARRAY PV ARRAY 0 El 000 0 o ❑ MsP Efl 21412 96TH AVENUE W, EDMONDS, WA, 98020 DIRECTORY PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM. (ALL PLAQUES AND SIGNAGE WILL BE INSTALLED AS OUTLINED WITHIN: NEC 690.56(B)&(C), [NEC 705.101) Revolution Energy Systems Inc. 9981 West 190th St Unit K Mokena IL 60448 T: 708-995-1643 SITE INFORMATION LESLIE BROWN 21412 96TH AVENUE W EDMONDS, WA, 98020 AC System Size: 7.6 kW AC DC System Size: 10.00 kW DC Lat, 47.8047240 Long,-122.3618928 (25) HANWHA Q.PEAK DUO L-G5.2 400 PV Modules (1) SOLAREDGE SE760OH-US (240V) Inverter(s) (25) SOLAREDGE P400 Optimizers SNOHOMISH COUNTY PUBLIC UTILITY DISTRICT DRAWN BY: V.MIRAFLOR DATE: 8/19/2022 PLACARD - PV08 SITE PHOTOS: Ng so to's 1 Revolution Energy Systems Inc. 9981 West 190th St Unit K Mokena IL 60448 T: 708-995-1643 SITE INFORMATION LESLIE BROWN 21412 96TH AVENUE W EDMONDS, WA, 98020 AC System Size: 7.6 kW AC DC System Size: 10.00 kW DC Lat, 47.8047240 Long,-122.3618928 (25) HANWHA Q.PEAK DUO L-G5.2 400 PV Modules (1) SOLAREDGE SE760OH-US (240V) Inverter(s) (25) SOLAREDGE P400 Optimizers SNOHOMISH COUNTY PUBLIC UTILITY DISTRICT DRAWN BY: V.MIRAFLOR DATE: 8/19/2022 SITE PHOTOS - PV09 powered by a` DUO Q.ANTUM TECHNOLOGY: LOW LEVELISED COST OF ELECTRICITY Higher yield per surface area, lower BOS costs, higher power classes, and an efficiency rate of up to 20.3%. INNOVATIVE ALL-WEATHER TECHNOLOGY Optimal yields, whatever the weather with excellent low -light and temperature behaviour. ENDURING HIGH PERFORMANCE Long-term yield security with Anti LID Technology, Anti PID Technology', Hot -Spot Protect and Traceable Quality Tra.QTM" EXTREME WEATHER RATING High-tech aluminium alloy frame, certified for high snow (5400 Pa) and wind loads (2400 Pa). A RELIABLE INVESTMENT Inclusive 12-year product warranty and 25-year linear performance warranty2. STATE OF THE ART MODULE TECHNOLOGY Q.ANTUM DUO combines cutting edge cell separation and innovative wiring with Q.ANTUM Technology. 1 APT test conditions according to IEC/TS 62804-1:2015, method B (-1500 V, 168 h) 2 See data sheet on rear for further information. THE IDEAL SOLUTION FOR: Rooftop arrays on AN Ground -mounted ��✓� commercial/industrial aw solar power plants buildings i MECHANICAL SPECIFICATION Format 79.3in x 39.4in x 1.38in (including frame) (2015 mm x 1000 mm x 35 mm) Weight 51.8 lbs (23.5 kg) Front Cover 0.13 in (3.2mm) thermally pre -stressed glass with anti -reflection technology Back Cover Compositefilm Frame Anodized aluminum Cell 6 x 24 monocrystalline Q.ANTUM solar half cells Junction Box 2.09-3.98 x 1.26-2.36 x 0.59-0.71 in (53-101 x 32-60 x 15- 18 mm), Protection class IP67, with bypass diodes Cable 4mm2Solar cable; (+)z53.1in(1350mm),(-)z53.1in(1350mm) Connector Staubli MC4, Staubli MC4-Evo2, Amphenol UTX, Renhe 05-8, Tonglin TL-CableOlS-F; IP68 or Friends PV2e; IP67 mrla Tflloulee.,a aww•,N 1`--'�,rao.,.x ,y ELECTRICAL CHARACTERISTICS POWER CLASS 380 385 390 395 400 405 MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC1(POWER TOLERANCE +5 W /-0 W ) Power at MPP1 PI [W] 380 385 390 395 400 405 E Short Circuit Current' Isc [A] 10.05 10.10 10.14 10.19 10.24 10.28 E Open Circuit Voltage' Voc IV] 4795 48.21 48.48 48.74 49.00 49.26 5 Current at MPP I_ [A] 9.57 9.61 9.66 9.70 9.75 9.79 Voltage at MPP VMPP IV] 39.71 40.05 40.38 40.71 41.04 41.36 Efficiency' q [%] a18.9 >-19.1 2:19.4 >-19.6 z19.9 z20.1 MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS, NIVI Power at MPP PI,,PP [WI 284.4 288.2 291.9 295.6 299.4 303.1 E Short Circuit Current Isc [A] 8.10 8.14 8.17 8.21 8.25 8.28 E c Open Circuit Voltage Voc IV] 45.21 45.46 45.71 45.96 46.21 46.45 i Current at MPP IMpp [A] 7.53 757 760 764 767 771 Voltage at MPP V111P IV] 37.77 38.08 38.40 38.71 39.02 39.33 'Measurement tolerances P„ p±3%; Isc; Vac ±5%at STC:1000 W/m2, 25±2°C. AM 1.5G according to IEC 60904-3. 2800 W/m2, NMOT, spectrum AM 1.5G O CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE - -- U2 M At least 98%of nominal power during 110 ;-r----i-----r-----� first year. Thereafter max. 0.54% degradation per year. At least 93.1% of nominal power up to 10 years. At i least 85%of nominal power up to ' W I I I I > , 25Years. 'a w--r----- r----- r-----r------ I I I All data within measurement toleranc- es. Full warranties in accordance with the warranty terms of the Q CELLS IRRADIANCE w/m'1 sales organisation of your respective country. YEARS Typical module performance under low irradiance conditions in comparison to STC conditions (25 °C. 1000 W/m2) TEMPERATURE COEFFICIENTS Temperature Coefficient of Isc a [%/K] +0.04 Temperature Coefficient of Voc B [%/K] -0.27 Temperature Coefficient of P_ y [%/K] -0.36 Normal Module Operating Temperature NMOT [°F] 109±5.4 (43±3°C) PROPERTIES FOR SYSTEM DESIGN Maximum System Voltage V.I. IV] 1500(IEC)/1500 (UL) Safety Class II Maximum Series Fuse Rating [A DC] 20 Fire Rating C/TYPE 1 Max. Design Load, Push/Pu113 [Ibs/ft2] 75(3600P8)/33(1600P8) Permitted Module Temperature -40°Fupto+185°F Max. Test Load, Push/PuIP [Ibs/ft2] 113(5400P8)/50(2400Pa) °nContinuous Duty (-40°Cupto+85°C) 3 See Installation Manual QUALIFICATIONS AND CERTIFICATES PACKAGING INFORMATION UL 1703. CE-compliant, IEC 61215:2016. IEC 61730:2016. Number of Modules per Pallet 29 Application Class II. V.S. Patent No.9.893.215 (solarcells) Number of Pallets per 53' Trailer 27 C S�R EVE ca,,,,us Number of Pallets per 40' HC-Container 22 Pallet Dimensions (L xWx H) 81.9 x 45.3 x 46.9in (2080 x 1150 x 1190mm) Pallet Weight 1635lbs (742kg) Note: Installation instructions must be followed. See the installation and operating manual or contact our technical service department for further Information on approved installation and use of this product. OCELLS 40nwhetrCELLSer Drive. Inc. Engineered in Germany 400SpecVumCenterDrive.Suite1400. Irvine, CA92618. USA ITEL+1949748-59961 EMAIL inquiry@us.q-cells.com I WEB www.ci-cells.com/ne Single Phase Inverter with HD -Wave Technology for North America SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US / SE760OH-US / SE1000OH-US / SE1140OH-US O O O O solar,3�[ itiD,:,., solar3.GC _HD O ® O O O � O O O O ! ! 12-25 YEAR WARRANTY Optimized installation with HD -Wave technology O / Specifically designed to work with power optimizers / UL1741 SA certified, for CPUC Rule 21 grid compliance / Record -breaking 99% weighted efficiency / Small, lightweight, and easy to install both outdoors or indoors / Quick and easy inverter commissioning directly from a smartphone using the SolarEdge SetApp / Fixed voltage inverter for longer strings / Integrated arc fault protection and rapid shutdown for NEC 2014, NEC 2017 and NEC 2020 per article 690.11 and 690.12 / Built-in module -level monitoring / Optional: Faster installations with built-in consumption metering (1% accuracy) and production revenue grade metering (0.5% accuracy, ANSI C12.20) solaredge.com solar=@@ / Single Phase Inverter with HD -Wave Technology for North America SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US/ SE760OH-US / SE1000OH-US / SE1140OH-US OUTPUT Rated AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 @ 240V VA 3300 @ 208V 5000 @ 208V 10000 @ 208V Maximum AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 @ 240V VA 3300 @ 208V 5000 @ 208V 10000 @ 208V AC Output Voltage Min.-Nom.-Max. ✓ ✓ ✓ ✓ ✓ ✓ ✓ Vac (211 - 240 - 264) AC Output Voltage Min.-Nom.-Max. ✓ _ ✓ _ - ✓ Vac (183 - 208 - 229) AC Frequency (Nominal) 59.3 - 60 - 60.50) Hz Maximum Continuous Output 12.5 16 21 25 32 42 47.S A Current @240V Maximum Continuous Output - 16 - 24 - - 48.5 A Current @208V Power Factor 1, Adjustable - 0.85 to 0.85 GFDI Threshold 1 A Utility Monitoring, Islanding Protection, Yes Country Configurable Thresholds INPUT Maximum DC Power @240V 4650 5900 7750 1 9300 1 11800 1 15500 1 17650 W Maximum DC Power @208V - 5100 7750 15500 W Transformer -less, Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 1 400 Vdc Maximum Input Current @240V14 8.5 10.5 13.5 1 16.5 1 20 1 27 1 30.5 Adc Maximum Input Current @208V" - 9 - 13.5 1 - - 27 Adc Max. Input Short Circuit Current 45 Adc Reverse -Polarity Protection Yes Ground -Fault Isolation Detection 500ku Sensitivity Maximum Inverter Efficiency 99 99.2 % CEC Weighted Efficiency 99 99 @ 240V 98.5 @ 208V % Nighttime Power Consumption < 2.5 W (1) For other regional settings please contact SolarEdge support (2) A higher current source may be used; the inverter will limit its input current to the values stated Single Phase Inverter with HD -Wave Technology for North America SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US/ SE760OH-US / SE1000OH-US / SE1140OH-US ADDITIONAL FEATURES Supported Communication Interfaces RS485, Ethernet, ZigBee (optional), Cellular (optional) Optionaloi Revenue Grade Metering, ANSI C12.20 Consumption metering Inverter Commissioning With the SetApp mobile application using Built-in Wi-Fi Access Point for Local Connection Rapid Shutdown - NEC 2014, NEC 2017 and NEC 2020, 690.12 Automatic Rapid Shutdown upon AC Grid Disconnect STANDARD COMPLIANCE Safety UL1741, UL1741 SA, UL169913, CSA C22.2, Canadian AFCI according to T.I.L. M-07 Grid Connection Standards IEEE1547, Rule 21, Rule 14 (HI) Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size / AWG Range 1" Maximum / 14-6 AWG 1" Maximum /14-4 AWG DC Input Conduit Size / # of Strings / AWG Range 1" Maximum / 1-2 strings / 14-6 AWG 1" Maximum / 1-3 strings / 14-6 AWG Dimensions with Safety Switch (HxWxD) 17.7 x 14.6 x 6.8 / 450 x 370 x 174 21.3 x 14.6 x 7.3 / 540 x 370 x 185 in / mm Weight with Safety Switch 22110 25.1 / 11.4 26.2 / 11.9 38.8 / 17.6 In / kg Noise < 25 1 <50 dBA Cooling Natural Convection Operating Temperature Range -40 to +140 / -40 to +041 `F / `C Protection Rating NEMA 4X (Inverter with Safety Switch) (3) Inverter with Revenue Grade Meter P/N: SExxxxH-US000BNC4; Inverter with Revenue Grade Production and Consumption Meter P/N: SExxxxH-US000BNI4. For consumption metering, current transformers should be ordered separately: SEACT0750-20ONA-20 or SEACT0750-400NA-20. 20 units per box (4) Full power up to at least 50'C / 122'F; for power de -rating information refer to: https://—w.solaredge.com/sites/default/files/se-temperature-derating-note-na.pdf How to Enable Consumption Monitoring By simply wiring current transformers through the inverter's existing AC conduits and connecting them to the service panel, homeowners will gain full insight into their household energy usage helping them to avoid high electricity bills Single phase inverter with HD -wave technology and built-in RGM and Service Panel consumption monitoring co 1 0 --- 1-111 ----------------- AC Conduit ® SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All Ro H S other trademarks mentioned herein are trademarks of their respective owners. Data: 12/2020N01/ENG NAM. Subject to change without notice. Power Optimizer For North America P370 / P400 / P401 / P485 / P505 PV power optimization at the module -level / Specifically designed to work with SolarEdge inverters / Up to 25% more energy / Superior efficiency (99.5%) / Mitigates all types of module mismatch losses, from manufacturing tolerance to partial shading / Flexible system design for maximum space utilization / Fast installation with a single bolt / Next generation maintenance with module - level monitoring / Meets NEC requirements for arc fault protection (AFCI) and Photovoltaic Rapid Shutdown System (PVRSS) / Module -level voltage shutdown for installer and firefighter safety Power Optimizer For North America P370 / P400 / P401 / P485 / P505 Rated Input DC Power01 370 400 430 485 505 W Absolute Maximum Input Voltage (Voc at lowest temperature) 60 80 60 125e) 83u) Vdc MPPT Operating Range 8-60 8-80 8-60 12.5 -105 12.5 - 83 Vdc Maximum Short Circuit Current (Isc) 11 10.1 12.5 11 14 Adc Maximum DC Input Current 13.75 12.5 14.65 12.5 17.5 Maximum Efficiency 99.5 % Weighted Efficiency 98.8 % Overvoltage Category II OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output Current 15 Adc Maximum Output Voltage 60 80 Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety Output Voltage per Power Optimizer 1 ± 0.1 Vdc STANDARD COMPLIANCE EMC FCC Part 15 Class B, IEC61000-6-2, IEC61000-6-3 Safety IEC62109-1 (class II safety), UL1741, NEC/PVRSS Material UL94 V-0 , UV Resistant ROHS Yes INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Compatible inverters All SolarEdge Single Phase and Three Phase inverters Dimensions(WxLxH) 129x153x27.5/ 5.1x6x1.1 129x153x33.5/ 5.1x6x1.3 129x153x29.5/ 5.1x6x1.16 129x159x49.5/ 5.1x6.3x1.9 129x162x59/ 5.1x6.4x2.3 mm /in Weight (including cables) 630/1.4 750/1.7 655/1.5 845/1.9 1064/2.3 gr/Ile Input Connector MC4o) MC43r MC4(3) Input Wire Length 0.16 / 0.5 m / ft Output Wire Type / Connector Double Insulated / MC4 Output Wire Length 1.2 / 3.9 m / ft Operating Temperature Range (4) -40 to +85 / -40 to +185 °C / `F Protection Rating IP68 / Type6B Relative Humidity 0 -100 % (1) Rated power of the module at STC will not exceed the optimizer "Rated Input DC Power". Modules with up to +5%power tolerance are allowed (2) NEC 2017 requires max input voltage be not more than 80V (3) For other connector types please contact SolarEdge (4) Longer inputs wire lengths are available for use. For 0.9m input wire length order P401-xxxLxxx (5) For ambient temperature above +85°C / +185°F power de -rating is applied. Refer to Power Optinnizers Temperature De -Rating Technical Note for more details: https.//www.solaredge.com/sites/defauVfles/se- temperatu re-d erating-note-na. pdf Minimum String Length P370, P400, P401 8 10 18 (Power Optimizers) P485, P505 6 8 14 Maximum String Length (Power Optimizers) 25 25 50 5700'n (6000 with Maximum Power per String SE7600-US - SE11400-US) 5250�i 6000'r 12750i10 W Parallel Strings of Different Lengths or Orientations Yes (6) For detailed string sizing information refer to: http://w .solaredge.com/sites/default/fles/string-sizing-na.pdf (7) It is not allowed to mix P485/P505 with P370/P400/P401 in one string (8)A string with more than 30 optimizers does not meet NEC rapid shutdown requirements; safety voltage will be above the 30V requirement (9) For 208V grid: it is allowed to install up to 6,50OW per string when the maximum power difference between each string is 1,000W (10)For 277/480V grid: it is allowed to install up to 15,000W per string when the maximum power difference between each string is 2,000 W solaredge.com solar=@@ ©SOIarEd eTechnolo Ltd. Alld hts reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks orr registered trademarks of SolarEd Technologies, g gins g ge g change ge gies,lnc -00. RoHS All other trademarks mentioned herein are trademarks of their respective owners. Date: February 10, 2022 DS-000044-NA. subject to change without notice. Intertek SUNMOI7 Part Number Description K50058-BK1 NanoMount . NanoMount . USWR Gasket NanoMount Material: Aluminum Finish: Black Powder Coating NanoMount Gasket Material: USWR Gasket with Adhesive D10214-VO04 Dimensions shown are inches (and millimeters) 9 Details are subject to change without notice SUNMO11IF'O Part Number Description K50049-BK1 Lag Bolt Assembly • Hex Lag Bolt M8X1 15, DIN 571, 304S • Sealing Washer .33 ID X .75 X .157 K50055-BK1 Decking Screw Assembly . Self -Tapping Screw, #14 X 3.00 . Sealing Washer .261D X .50X .125 Lag Bolt Assembly 1. Hex Lag Bolt M8X1 15, DIN 571, 304 Material: Stainless Steel Finish: Clear 2 Sealing Washer .331D X.75X.157 r F— — I pssl sous ne of I I I'— — r � Material: EPDM + Stainless Steel Decking Screw Assembly 1. Self Tapping Screw, #14 X 3.00 HLK :-.._._- .................................. on + 89J Material: Stain Finish: Clear 2. Sealing Washer .261D X .50X .125 r _ 0.: I \ MW Oo ss I t I I t1 !J I t• — � i Material: EPDM + Stainless Steel D10214-VO04 pimensions shown are inches (and millimeters) Details are subject to change with xd notice SUNMOD'O Part Number Description A20422-168-BK SMR100 Rail, Black Anodized, 168" A20453-168-BK SMR200 Rail, Black Anodized, 168" A20440-BK1 Rail End Cap, SMR100, Black A20440-BK2 Rail End Cap, SMR200, Black SMR100 Rail Mechanical Properties Section Properties Material: 6005-T5 Aluminum Sx: 0.196 in3 (3.21 cm) Weight: 0.4126 Ibs/ft (0.614 kg/m) Sy: 0.146 in3 (2.39 cm3) Ultimate Tensile Strength: 37.7 ksi (260 MPa) Area (X-section): 0.352 in (2.27 cm') Yield Strength: 34.8 ksi (240 MPa) SMR200 Rail Mechanical Properties Section Properties Material: 6005-T5 Aluminum Sx: 0.321 in3 (5.26 cm3) Weight: 0.645 Ibs/ft (0.960 kg/m) Sy: 0.272 in3 (4.46 cm3) Ultimate Tensile Strength: 37.7 ksi (260 MPa) Area (X-section): 0.551 in2 (3.55 cm2) Yield Strength: 34.8 ksi (240 MPa) D10225-VO04 Dimensions shown are inches (and millimeters) Details are subject to change without notice SUNMOMWO Part Number Description K10421-002 Structural Splice, SMR100 K10462-002 Structural Splice, SMR200 K10433-BK1 L Foot Adaptor, SMR100, Black K10434-BK1 L Foot Adaptor, SMR200, Black SMR100 Bonding Rail Splice s� ,+as of ]91 ,5z5, L O hnn NE%IXtlVE SMR200 Bonding Rail Splice 2 zoo u s1 O L SMR100 L-Foot Adaptor — 1.40 135.SJ SMR200 L-Foot Adaptor `—NEx ' 138 135.0) 1.37 134.e1 0mm HEX DRNE 2.0) 150.71 1 1.37 134 9J Materials: 1. Extrusions 6005-T5 Aluminum 2. Hardware 304 Stainless Steel D10225-VO04 Dimensions shown are inches (and millimeters) —00 15oe1 0 6mm HEX ERNE J Details are subject to change without notice SUNM*00`0 Part Number Description K10417-BK3 Mid Clamp, SMR Pop -On, Black K10418-BK3 End Clamp, SMR Pop -On, Black K10419-BK1 Shared Rail Mid Clamp, SMR Pop -On, Black K10420-BKl Shared Rail End Clamp, SMR Pop -On, Black Pop -On Bonding Mid Clamp 8mm HEX DRIVER REQUIRED Pop -On End Clamp 0.47 112.0] 1 RANGE 30-48mm 8mm HEX DRIVER REQUIRED j�RANGE 7W&nn 1 Shared Rail Bonding Mid Clamp &— HEX DRIVER REQUIRED Shared Rail End Clamp 049 -- I12AI RANGE 0 8mm HEX DRIVER �REWIRED 7 RANGE Materials: 1. Extrusions 6005-T5 Aluminum 2. Hardware 304 Stainless Steel D10225-V004 Dimensions shown are inches (and millimeters) Details are subject to change without notice