Loading...
APPROVED ENG BLD PLN RESUB 1-Architectural_PlanSD 104'--_ -- 6 SD SD SD BECK LANE (ALLEY SD8" CONC SD I I / / 0� i 105.00' EL. ADU PARKING LO ° I 3.5'X22' GRASS a I ° STALL' o6 ° INLAYS .00 0,000C ' EL. Ln.J I I I I i This area shall match ' -7' the surface material I of the alley (asphalt — — — or gravel) where vehicles will be d ' ' t th NEW CONCRETE I a I �/ I I rlving ono e 26.50' z I subject site from the DRIVEWAY 606 SF I oid alley. N I, 1 N ('FOOTPRINT.- .50'MAIN HOUSE �-�� II -�� � I I IPARKING STALLS ' 8.�0i' i' ' 8 O' a' PROPOSED ADU z FT 857 S.F. I IC ROOFTOP: 1,162 SF I I ACCEPTABLE TIGHTLINE i NEW CONCRETE PATIO ° I o TOTAL LIVING SPACE: I , I MATERIAL: / 60 SF OUTSIDE I o � 0 798 SF I / I SDR 35 OF ROOF LINE X. � o� 00 I I N-12 F810 HANCOR EXISTING SHED TO BE / REMOVED AND REPLACE L--------- WITH LAWN -231 /`1 F. ' 7. 8.50' , y ' / o ° i I ALL DISTURBED SOILS SHALL BE O I - COMPOST AMENDED PER CITY OF �0 _ _ — EDMONDS STANDARD DETAIL SD-642 OR � N y I APPROVED EQUAL. / I , 9.50' N I gyp/ c)------J NEW DEC AND STEPS PROPOSED i I o I I / 149 SF BREEZEWAY I r-------� ,' 23.47' I- ---------:7DE�CK N JJ o l I I I - AND REEMO / BUILD cn STING � � � w 4.00 EX. MAIN HOUSE ICU / , - J o FOOTPRINT 864 SF I I � I , , ROOFTOP: 1, 138 SF I I TOTAL LIVING SPACE. L------- I 2,386 SF o / � I EX. HOUSE#629 I S, , - 1� I EX. HOUSE#639 10 L �2-o, FRONT BSBL / COVERED FRONT -� r — — — - PORCH ---� I _ 10'_-- -- -- -L — — — '-�- -� I I Q I I 2 — D 1 L------ J / / J t/ --� WATER a a - - SW CORNER METER o 1 1 1.0' EL. 00' °166. °x OVERHEAD POWEPR P F- o ® CURB�E Cn -' U. - - rn 8 C-I -WATER MAIN _W- W -- W --- W W W --T-- orn- c� �z 8" CONC. SEWER MAIN SS �' SS SS SS SS o WALNUT ST. 12 " CONC SD SD SD SD SW o s0 o ' CURB LI E J� O °° M P� W a_ 11 DATUM POINT / DOWNER/CONTRACTOR RESPONSIBLE FOR LOCATING SE PROPERTY ALL ON SITE UTILITIES. RELOCATION/REVISION TO ANY UTILITIES MAY REQUIRE A SEPERATE PERMIT. CORNER 1 12.5 EL. ' P' / W �- SS SCALE 1" = 10' 10' 0' 5' 10' 20' PROJECT DATA PROPERTY OWNER/APPLICANTS: BARBARA TOLLEFSON 633 WALNUT ST EDMONDS, WA 98020 PROJECT CONTACT/PLAN PREPARER: PUGET SOUND PLANNING, LLC ATTN: LEE A. MICHAELIS, AICP 5005 200TH ST SW, UNIT 101- B LYNNWOOD, WA 98036 (425) 830-1046 LEE. MICHAELIS@PUGETSOUNDPLANNING.COM SITE DATA SITE ADDRESS: 633 WALNUT ST PARCEL NUMBER:00 4342 094 029 00 TOTAL LOT AREA: 6.600 SF (0.15 AC) ZONING: RS-6 BUILDING SETBACK LINES (BSBL): STREET: 20 FEET SIDE: 5 FEET REAR: 15 FEET MAXIMUM BUILDING HEIGHT: 25' MAXIMUM COVERAGE: 35 PERCENT PROPOSED ACCESSOR Y DWELLING UNIT r �— —, B _ - o �J pO Emerald HillsJL Edmonds Unde water' A 6�r� Edrnonds� o C EdmoridC L7 ❑w o ��10 O Boat RepaiF= c Yard ;h Edmonds - ��� �� Shell� Marsh ,p b Edmonds la. r� I.L.. Q _......... WAj10144--iPine StreetPark Neighborhood' ---I T G z 0ffi et� out WA 104 UI MAIN FLOOR (INSIDE EXTERIOR WALLS): 798.0 SF COVERED PORCH: 84.5 SF REPLACE EXISTING HOUSE DECK: 149.0 SF LEGAL DESCRIPTION LOTS 29 AND 30, BLOCK 94, CITY OF EDMONDS, ACCORDING TO THE PLAT THEREOF, RECORDED IN VOLUME 2 OF PLATS, PAGE 39, RECORDS OF SNOHOMISH COUNTY, WASHINGTON SITUATE IN THE COUNTY OF SNOHOMISH, STATE OF WASHINGTON. STRUCTURAL LOT COVERAGE LOT AREA: 6,600 SF EXISTING HOUSE FOOTPRINT: 864 SF EXISTING FRONT PORCH: 140 SF PROPOSED ADU: 858 SF PROPOSED BREEZEWAY: 52 SF > PROPOSED DECK: 149 SF TOTAL LOT COVERAGE: 2,063 SF 31.3% AVERAGE HEIGHT CALCULATIONS CORNER POINT ELEVATIONS NORTHWEST CORNER = 105.75' NORTHEAST CORNER = 107.25' SOUTHEAST CORNER = 111.75' SOUTHWEST CORNER = 110.25' AVERAGE GRADE: W (435.00' / 4) = MAXIMUM HEIGHT = (AVERAGE GRADE + 25') ACTUAL HEIGHT OF ADU = SS - P —F—F P — F P — P — P — �' P P P IMPERVIOUS SURFACE CALCULATIONS 435.00' 108.75' 133.44' 1 15.20' SLOT AREA: 6,600 SF EXISTING HOUSE ROOFTOP: 1,138 SF EXISTING FRONT WALKWAY: 39 SF EXISTING STORAGE SHED: 231 SF EXISTING REAR DECK: 50 SF EXISTING REAR CONCRETE WALKWAY/PATIO: 390 SF TOTAL EXISTING: 1,851 SF REMOVE EXISTING STORAGE SHED: 231 SF REMOVE EXISTING REAR DECK: 50 SF REMOVE REAR CONCRETE WALKWAY/PATIO: 390 SF TOTAL REMOVED: -671 SF PROPOSED ADU ROOFTOP: 1,162 SF PROPOSED DECK 149 SF PROPOSED CONCRETE DRIVEWAY: 606 SF PROPOSED UNCOVERED CONCRETE PATIO: 60 SF TOTAL PROPOSED: 1,977 SF TOTAL NEW IMPERVIOUS SURFACE: 1,977 SF VICINITY MAP 1 " = 2,000' Zone Corner - Flag --- Setbacks: Required Actual Front Sides Rear Other Height Approved by i 11/30/2021 AFM KF�tter r Applicant shall repair/replace all damage to utilities or frontage improvements in City right-of-way per city standards that is caused or occurs during the permitted project. ENGINEERING DIVISION APPROVED AS NOTED 12/17/2021 ***See Civil Plan, Sheet C1 in the Architectural Plan for additional engineering comments. No stormwater management system required at this time. If new and/or replaced impervious surface equals 2000sgft or greater than a stormwater management system will be required per City codes and standards. *** APPROVED BY PLANNIN 12/9/2021 RESUB Nov 29 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT W w 0 W Qcz � U 0 C' z o o m o� o 0 �o� o z 0zo �Zd � Ln Ln le A. O >, eX2 C1 e � O v Z Q J W E-- V'� Z >—WO C) U z W W m � Z z O Q W UJ .J M O M DRAWN DATE: 10/04/2021 DRAWN BY: LAM CHECKED BY: TL PSP PROJECT NO. 2021-31 SHEET NAME S ITE P LAN SHEET NUMBER AO PRINT DATE: 11/29/2021 GENERAL NOTES AREA CALCULATIONS , s[ x GENERAL REQUIREMENTS ALL WORK SHALL COMPLY WITH THE 2018 EDITION OF THE INTERNATIONAL BUILDING CODE (STRUCTURAL DESIGN), NEW A.D.U. LIVING SPACE SQUARE FOOTAGE 6 ' 01 INTERNATIONAL RESIDENTIAL CODE (ORDINANCE), MOST RECENT EDITION OF THE UNIFORM PLUMBING CODE,` INTERNATIONAL MECHANICAL CODE, NATIONAL ELECTRIC CODE, WASHINGTON STATE ENERGY CODE, ANY STATE MAIN FLOOR 798.0 S.F. AND LOCAL AMENDMENTS, AND ANY APPLICABLE LAND USE CODE. t • . - THE OWNER/BUILDER SHALL BE RESPONSIBLE FOR DEVELOPING CONSTRUCTION DETAILS NECESSARY TO TOTAL 798.0- -- CONSTRUCT A WEATHER TIGHT, DURABLE BUILDING. ALL FLASHING, WEATHERPROOFING, ROOFING AND--ow- WATERPROOFING DETAILS AND CONSTRUCTION OF THESE DETAIL ASSEMBLIES ARE THE FULL AND COMPLETE RESPONSIBILITY OF THE OWNER/BUILDER AND THESE DETAILS SHALL BE CONSTRUCTED PER MANUFACTURER NON -HEATED AREAS SQUARE FOOTAGE_ --- REQUIREMENTS, BUILDING CODE REQUIREMENTS AND ACCEPTED INDUSTRY STANDARDS FOR PERFORMANCE.THE DESIGNER HAS NOT BEEN CONTRACTED TO PERFORM CONSTRUCTION ADMINISTRATION SERVICES OR COVERED PORCH 84.5 ��•,�� `� r CONSTRUCTION OBSERVATION SERVICES FOR THIS PROJECT AND IS NOT LIABLE OR RESPONSIBLE FOR DETERMINING ADEQUACY OF CONSTRUCTION OF BUILDING ENVELOPE OR DETAILS. THE OWNER/BUILDER SHALL REPLACEMENT DECK AT OLD HOUSE 149.0 '+ _ BE RESPONSIBLE FOR INSPECTING AND VERIFYING THAT ALL FLASHING, WEATHERPROOFING, ROOFING AND WATERPROOFING DETAILS ARE BUILT CORRECTLY AND MEET OWNER/BUILDER'S APPROVAL BEFORE BEING°- COVERED BY SUBSEQUENT CONSTRUCTION WORK. USE OF THESE PLANS BY ANYONE OTHER THAN THE INTENDED OWNER/BUILDER IS NOT PERMITTED.` - ANY REDUNDANCY BETWEEN THESE NOTES AND S-SHEETS THE S-SHEETS SHALL SUPERSEDE. Ij SITE WORK i y - - 1. BACKFILL FOUNDATION DRAIN AT PERIMETER OF BUILDING WITH COURSE GRANULAR FILL. (1 1/2-3/8 CLEAN WASHED ROCK WITH MIN. 12" WIDE BLANKET EXTENDING TO FINISHED GRADE.) PROTECT DRAIN TILE AND WATERPROOFING.--- 2. ROUGH GRADING SHALL PROVIDE POSITIVE DRAINAGE AWAY FROM BUILDING. TRENCH TO ELEVATIONS BELOW FROST LINE FOR STORM DRAINS, WATER LINES, SEWERS, AND IRRIGATION SLEEVES. I I - •+ r. 3. PROVIDE PERFORATED PLASTIC PIPE FOUNDATION DRAINS WHERE SHOWN IN DRAWINGS. CONNECT TO - ROOF AND STORM WATER SYSTEM. IN JURISDICTIONS REQUIRING SEPARATE ROOF DRAIN LINES, PROVIDE TIGHT LINE CONNECTED TO ROOF DRAINS IN ADDITION TO PERFORATED DRAIN LINES. DRAWING INDEX 4. ROCKERIES AND RETAINING WALLS SHALL BE DESIGNED BY A LICENSED ENGINEER AND INSTALLED PER APPLICABLE CODE. r' - MECHANICAL i - 1. PLUMBING SYSTEMS SHALL BE DESIGNED AND INSTALLED BY COMPETENT EXPERIENCED PLUMBER AND IN SHEET NO. DESCRIPTION .� - $._ . _,. <;-._,,_,,.-sr_,-��,_..+;_ti,-. ,r..�..,.;:� . _ ._-,:..-.._. _..;-,��...;�::; �..,..:.,_.•,;,..-,:.:. ,.•......' = �.,,:..:.�; ;;. _ti �- k r r-; _ r / Yy ACCORDANCE WITH THE UNIFORM PLUMBING CODE AND LOCAL CODES. 2. HVAC SYSTEMS SHALL BE DESIGNED AND INSTALLED BY A COMPETENT AND EXPERIENCED MECHANICAL= ry+�_��i'rF�`7-Y. �,x, ..+c� Y}...-STi`�`'..-.':-i."-.:� .-�y.'e `ice- f" ��•_: - .i i..iY.:i�Jy f y� ,��1 y ::,: r,•;_�,_ �. '3A p k : �, ,;> _ , ti .y aaYa : T 'ram kh 'Y xi a- 4 �j �. r`•-1-.8n - - .ff 2a:: �''A�'f+•• y'fFi r.F%S-i'c.,Y',ya. � 4 ••�1,.. •i4 � _+• '.r },Ltlr i� i .."}.' r V�� CONTRACTOR IN ACCORDANCE WITH THE INTERNATIONAL MECHANICAL CODE, 2018 IRC, AND LOCAL CODES. _� rs1•• _;a�_��, . :;� : _-__ �. .,-- >;r;:..-5�K( ,:.,, -,, ,•.,Y-k: ;.,.�d;. .� +. �;,�;,_;,_�-.�._•''��� ,;�,.. ��..ut� �„�x,,,,nh��,y��r,_-.�,,,,��,�:�. �.,,,,_,r, , , �..:,�a;.,,a.�.,.. �_ gr,� �:. ., ,�::1, ,�,, �'S;��� _ s � 3 �rr •:4.� PROVIDE DOCUMENTATION OF FURNACE A.F.U.E. DUCTWORK INSULATION SHALL CONFORM TO THE Al COVER SHEET INDEX GENERAL NOTES - ..-�, _...y - ,; �; �.N.�. _��, X,..,.�.,,�.,�. _ .r .,., ' �,_•-�..,15,,- e o_�n4._:s� �,,.,.,• ,r, , - f - ,:••- ._ rr,��:."' •. r l .. 4-. .r f-...r..+w:.-r.,'.•tif-.s_ry' f'• .- ti�...F:..tir"7-:::-r i.-:'-..::.�e�y. .fir.^-ir . "di.. .`��'y-3�, ti.vs .: }•�'3,.g y.*7 - ~Y.. - .'?F .�`_f�•-.' Fig.s.�- �'.-. �� '.iy- - +a'_•. j' WASHINGTON STATE ENERGY CODE. WHEN INSTALLED IN GARAGE, HEATING UNITS SHALL BE PLACED SUCH.,.�..,r�_� A2 ENERGY CALCULATIONS ram; _ - Y` :e_ :..-.cam. •. y_ d'' _R:.�' _ i.,. -.`� i.- -_r .S-_ r+J._ Y,S; J.v�.•. �f 1. _i.-. .. r .. .i_....% i.t'' ..• .. •' =. ; ' fir• �=-.3,r.•._� �.:.?. -, �. ��` t, � _�"_� r.s._ .a} -��, F,k �s x �. w� .�. .:�„r � -_.. _.�,. � ,. ?�?r , �,, � �, THAT ALL PILOT LIGHTS, BURNERS, HEATING ELEMENTS, OR SWITCHES ARE LOCATED A MIN. OF 18" ABOVE THE GARAGE FLOOR. A3 ELEVATIONS A4 1ST FLOOR - NEW ADU THERMAL AND MOISTURE A5 EXISTING HOUSE MAIN AND 2ND FLOORS 1. INSULATION REQUIREMENTS SHALL MEET OR EXCEED THE LATEST EDITION OF THE WASHINGTON ENERGY CODE A6 S1 BUILDING SECTIONS AND MISC. DETAILS STRUCTURAL NOTES/SCHEDULES OR ENERGY CODE ADOPTED BY THE LOCAL JURISDICTION. INSULATION REQUIREMENTS SHALL BE SHOWN ON PLANS OR ON A SEPARATE ENERGY CALCULATION SHEET. S2 FOUNDATION PLAN, SHEARWALL & HOLDOWN LOCATIONS ' 2. APPLY 1 COAT (MIN) HEAVY BODIED ASPHALT BITUMINOUS DAMPPROFING TO EXTERIOR OF FOUNDATION WALLS, FROM FOOTING TO FINISHED GRADE AT FOUNDATION WALLS THAT RETAIN EARTH AND ENCLOSE S3 MAIN FLOOR FRAMING -� ='= -- -- INTERIOR SPACES AND FLOORS BELOW GRADE.. (R406.1) 3. APPLY APPROPRIATE WATER REPELLENTS TO ANY MASONRY, CEMENT, PLASTER, OR STUCCO PER��Tr�T�rr MANUFACTURER'S INSTRUCTIONS. S4 S5 ROOF PLAN STRUCTURAL DETAILS - _ _ •- _ -_ _ - ----- 4. PROVIDE 6 MIL BLACK POLYETHYLENE VAPOR BARRIER IN ALL CRAWLSPACE AREAS, LAPPED AT ALL SPLICES AND OVER FOOTINGS. _ _ ___ FINISHESr GARAGE CEILINGS BENEATH HABITABLE SPACES SHALL BE COVERED WITH 5/8" TYPE "X" GYPSUM WALL BOARD. - GARAGE CEILINGS BENEATH ATTIC OR NON LIVING SPACE SHALL BE COVER WITH 5/81, GYPSUM WALL BOARD. r " WALLS AND STRUCTURE SEPARATING RESIDENTIAL AND GARAGE SPACES SHALL BE COVERED WITH 1/2" GYPSUM WALL BOARD. ALL GARAGE GYPSUM WALLBOARD SHALL HAVE JOINTS FIRETAPED WITH NAILS SET AND COMPOUNDED. ALL OTHER WALLS SHALL RECEIVE 1/2" GYPSUM WALLBOARD. CEILINGS WITH JOISTS/ TRUSS SPACES GREATER THAN 16" SHALL RECEIVE 5/8" GYPSUM WALLBOARD OR 1/2" GYPSUM CEILING BOARD. WALLS SURROUNDING TUBS OR SHOWERS SHALL BE COVERED WITH WATER-RESISTANT GYPSUM WALL BOARD. WATER- PROOF SURFACE TO A HEIGHT OF 72" ABOVE ADJACENT FLOOR. ANY CEMENT PLASTER OR STUCCO SHALL BE, INSTALLED IN ACCORDANCE WITH NORTHWEST WALL AND CEILING BUREAU RECOMMENDATIONS FOR MATERIALS, BACKING, LATH, APPLICATION TECHNIQUES, AND FINISHES. - ELECTRICAL SYSTEMS SHALL BE DESIGNED AND INSTALLED BY A COMPETENT AND EXPERIENCED ELECTRICAL CONTRACTOR IN SYMBOL LEGEND ACCORDANCE WITH MOST CURENT STATE AND LOCAL ELECTRICAL CODE. ELECTRICAL SCHEMATICS PROVIDED IN THIS SET OF PLANS ARE FOR REFERENCE LAYOUT ONLY. FIRESTOPPING CARBON MONOXIDE DETECTOR OO CANBEONNE INED110vw/BATTERYBACKUP c.o. CAN BE COMBINED w/ S.D.FIRESTOPPING 633 WALNUT STREET.,EDMONDS.,WA 98020 SHALL BE PROVIDED TO CUT OFF ALL CONCEALED DRAFT OPENINGS BOTH VERTICAL AND ( O SMOKE DETECTOR HORIZONTAL) AND TO FORM AN EFFECTIVE FIRE BARRIER BETWEEN STORIES, AND BETWEEN A TOP STORY AND S.D. INTERCONNECTED 110v w/ BATTERY BACKUP THE ROOF SPACE. FIRESTOPPING SHALL BE PROVIDED IN WOOD FRAME CONSTRUCTION IN THE FOLLOWING LOCATIONS: EXHAUST FAN (VENT TO OUTSIDE) O .. . . . . . . . ... ' INTERCONNECTED 1. IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING FURRED SPACES NOT TO EXCEED 10'-0" HORIZONTALLY, AND AT THE CEILING AND FLOOR LEVEL. APPROVED OBTAIN ELECTRICAL ' SMOKE ALARMS AND CO 2. AT ALL INTERCONNECTIONS BETWEEN CONCEALED VERTICAL AND HORIZONTAL SPACES SUCH AS OCCUR AT SOFFITS, DROP CEILINGS, COVE CEILINGS, ETC. O KEYNOTE , PERMIT FROM DETECTORS ARE A ; 3. IN CONCEALED SPACES BETWEEN STAIR STRINGERS AT THE TOP AND BOTTOM OF THE RUN AND WALL CAVITIES IN LINE WITH STRINGERS. 101 DOOR SCHEDULE SYMBOL PLANS MUST BE STATE LABOR & ' REQUIREMENT OF THIS ' ; 4. AT OPENINGS AROUND VENTS, PIPES, DUCTS, CHIMNEYS AND FIREPLACES AT CEILING AND FLOOR LEVEL, WITH NON-COMBUSTABLE MATERIALS. 11 WINDOW SCHEDULE SYMBOL ON JOB SITE INDUSTRIES PERMIT IN ACCORDANCE ; R314.2.2 ' Al REVISION -SEE DESCRIPTION IN ;WITH .................................... MISCELLANEOUS TITLE BLOCK 1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS, CONDITIONS, ETC. IN THE FIELD PRIOR TO PROCEEDING. � DE 1 SIMTAIL SYMBOL City Of Edmonds 2. VERIFY SIZE AND LOCATION OF ALL OPENINGS IN THE FLOOR, ROOF, AND WALL WITH MECHANICAL AND ELECTRICAL WORK. SIMILAR DETAIL 101 - DETAIL NO. City of Edmonds Building Department 3. PROVIDE SMOKE DETECTORS IN ACCORDANCE WITH (R314) SMOKE DETECTORS TO BE HARD WIRED AND INTERCONNECTED. (R314.4, R314.5). A SMOKE DETECTOR SHALL BE INSTALLED IN EACH SLEEPING ROOM AND OUTSIDE EACH SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS. (R314) CARBON MONOXIDE ALARMS SHALL BE INSTALLED OUTSIDE EACH SEPARATE SLEEPING AREA AND IN THE VICINITY OF THE SHEET NO. SIM l BUILDING CROSS SECTION Work ADU, DECK, PATIO Building Department -------------- A10 Address BEDROOMS. (R315) DETAIL NO. 633 WALNUT ST 4. KITCHEN RANGE, DRYER, BATH AND LAUNDRY ROOM VENTILATION DUCTS SHALL TERMINATE OUTSIDE THE BUILDING AND BE EQUIPPED WITH BACK DRAFT DAMPERS. SHEET NO. APPROVED Plans Owner TOLLEFSON 5. EXTERIOR OPENINGS TO THE WEATHER SHALL BE FLASHED AND COUNTER -FLASHED IN SUCH A MANNER AS TO Room name - ROOM NAME MAKE THEM WATERPROOF. ROOF FLASHING PER R903. --------- 6. GUARDRAILS TO BE A MIN. OF 36" ABOVE FINISH FLOOR. (R312) (EXCEPTIONS TO COMMERCIAL PER I.B.C.) Approved Date 12/13/2021 7. OPEN GUARDRAILS TO HAVE INTERMEDIATE RAILS OR PICKETS PLACED SUCH THAT A SPHERE 4" IN DIAMETER CANNOT PASS THROUGH. === Building Official ����� �ION M � 8. BEDROOM EMERGENCY EGRESS WINDOWS MUST HAVE A MIN. NET CLEAR OPENING OF 5.7 SQ. FT. MINIMUM NET CLEAR OPENABLE WIDTH OF 20" AND MIN. NET CLEAR OPENING HEIGHT OF 24". MAX. FINISHED HEIGHT OF ALL WORK SUBJECT 44" FROM FINISHED FLOOR TO BOTTOM OF CLEAR OPENING (R310.1). Permit Number B LD2021-1362 TO FIELD Know what's below. STATE LAW REQUIRES THAT YOU CALL BEFORE YOU DIG TO Call before dig. LOCATE ALL UNDERGROUND UTILITIES. INSPECTION FOR R E S U B you Nov 29 2021 CODE COMPLIANCE OF ETSERVIELOPMMENT DEVCITY SERVICES DEPARTMENT V z N CD coCD rn z >a o Q> U IL Y = Way W � N O "�� U J�a �Lo (aj M CO '2 z'0CD C LU ix o 0 LU m 0 LU a H E U fA \� C N T S m 3 J N S T Q@ y 0 a E 0 ozJo 0. UoUoEmnNC Q@ ��woa�.°� = O J O- O l C O -: p l9 O -6 = s N� wF�T'-6 wCT-E SEa>-yonmao�a`:n-°o O W U w o 0 00 U L F y@ y o U a o-.m Omc>n�a E H znorn oFE�m H Z W Z c Z a W a W 0 N p W z p z LU0 0 LU LU W t� N Cr LU LU W zVzr-a LUw w � Z � M O Q O m is c 0 0 z PROJECT NO. 210404 DESIGNED BY TL DRAWN BY TL & RM CHECKED BY TL SHEET NO. Al PRINT DATE 11 /21 /2021 2:51:27 PM R301 CLIMATE ZONE THIS PLAN IS DESIGNED FOR CLIMATE ZONE 5 AND MARINE 4 PER TABLE R301.1, 2018 WASHINGTON STATE ENGERY CODE. R402.2 FENESTRATION (PRESCRIPTIVE) R402.3 Fenestration (Prescriptive). In addition to the requirements of Section R402, fenestration shall comply with Sections R402.3.1 through R402.3.6. R402.3.1 U-factor. An area -weighted average of fenestration products shall be permitted to satisfy the U-factor requirements. R402.3.2 Glazed fenestration SHGC. An area -weighted average of fenestration products more than 50 percent glazed shall be permitted to satisfy the SHGC requirements. R402.3.3 Glazed fenestration exemption. Up to 15 square feet (1.4 m2) of glazed fenestration per dwelling unit shall be permitted to be exempt from U-factor and SHGC requirements in Section R402.1.1. This exemption shall not apply to the U- factor alternative approach in Section R402.1.3 and the total UA alternative in Section R402.1.4. R402.3.4 Opaque door exemption. One side -hinged opaque door assembly up to 24 square feet (2.22 m2) in area is exempted from the U-factor requirement in Section R402.1.1. This exemption shall not apply to the U-factor alternative approach in Section R402.1.3 and the total UA alternative in Section R402.1.4 R404.1 LIGHTING EFFICACY MIN. OF 75% OF LAMPS IN PERMANENTLY INSTALLED FIXTURES SHALL BE HIGH EFFICACY LAMPS. M 1507 MECHANICAL VENTILATION M1507.3.1 SYSTEM DESIGN. EACH DWELLING UNIT OR GUESTROOM SHALL BE EQUIPPED WITH A VENTILATION SYSTEM COMPLYING WITH SECTION M1507.3.4, M1507.3.5, M1507.3.6 OR M1507.3.7. COMPLIANCE IS ALSO PERMITTED TO BE DEMONSTRATED THROUGH COMPLIANCE WITH THE INTERNATIONAL MECHANICAL CODE. M1507.3.2 CONTROL AND OPERATION. 1. LOCATION OF CONTROLS. CONTROLS FOR ALL VENTILATION SYSTEMS SHALL BE READILY ACCESSIBLE BY THE OCCUPANT. 2. INSTRUCTIONS. OPERATING INSTRUCTIONS FOR WHOLE -HOUSE VENTILATION SYSTEMS SHALL BE PROVIDED TO THE OCCUPANT BY THE INSTALLER OF THE SYSTEM. 3. LOCAL EXHAUST SYSTEMS. LOCAL EXHAUST SYSTEMS SHALL BE CONTROLLED BY MANUAL SWITCHES, DEHUMIDISTATS, TIMERS, OR OTHER APPROVED MEANS. 4. CONTINUOUS WHOLE -HOUSE VENTILATION SYSTEMS. CONTINUOUS WHOLE -HOUSE VENTILATION SYSTEMS SHALL OPERATE CONTINUOUSLY. EXHAUST FANS, FORCED -AIR SYSTEM FANS, OR SUPPLY FANS SHALL BE EQUIPPED WITH "FAN ON" AS OVERRIDE CONTROLS. CONTROLS SHALL BE CAPABLE OF OPERATING THE VENTILATION SYSTEM WITHOUT ENERGIZING OTHER ENERGY -CONSUMING APPLIANCES. A LABEL SHALL BE AFFIXED TO THE CONTROLS THAT READS "WHOLE HOUSE VENTILATION (SEE OPERATING INSTRUCTIONS)." 5. INTERMITTENT WHOLE -HOUSE VENTILATION SYSTEMS. INTERMITTENT WHOLE -HOUSE VENTILATION SYSTEMS SHALL COMPLY WITH THE FOLLOWING: 5.1. THEY SHALL BE CAPABLE OF OPERATING INTERMITTENTLY AND CONTINUOUSLY. 5.2. THEY SHALL HAVE CONTROLS CAPABLE OF OPERATING THE EXHAUST FANS, FORCED -AIR SYSTEM FANS, OR SUPPLY FANS WITHOUT ENERGIZING OTHER ENERGY -CONSUMING APPLIANCES. 5.3. THE VENTILATION RATE SHALL BE ADJUSTED ACCORDING TO THE EXCEPTION IN SECTION 403.8.5.1. 5.4. THE SYSTEM SHALL BE DESIGNED SO THAT IT CAN OPERATE AUTOMATICALLY BASED ON THE TYPE OF CONTROL TIMER INSTALLED. 5.5. THE INTERMITTENT MECHANICAL VENTILATION SYSTEM SHALL OPERATE AT LEAST ONE HOUR OUT OF EVERY FOUR. 5.6. THE SYSTEM SHALL HAVE A MANUAL CONTROL AND AUTOMATIC CONTROL, SUCH AS A 24-HOUR CLOCK TIMER. 5.7. AT THE TIME OF FINAL INSPECTION, THE AUTOMATIC CONTROL SHALL BE SET TO OPERATE THE WHOLE -HOUSE FAN ACCORDING TO THE SCHEDULE USED TO CALCULATE THE WHOLE -HOUSE FAN SIZING. M1507.3.4 WHOLE -HOUSE VENTILATION USING EXHAUST FANS. THIS SECTION ESTABLISHES MINIMUM PRESCRIPTIVE REQUIREMENTS FOR WHOLE -HOUSE VENTILATION SYSTEMS USING EXHAUST FANS. A SYSTEM WHICH MEETS ALL THE REQUIREMENTS OF THIS SECTION SHALL BE DEEMED TO SATISFY THE REQUIREMENTS FOR A WHOLE -HOUSE VENTILATION SYSTEM. M1507.3.4.1 WHOLE -HOUSE VENTILATION FANS. EXHAUST FANS PROVIDING WHOLE -HOUSE VENTILATION SHALL HAVE A FLOW RATING AT 0.25 INCHES WATER GAUGE AS SPECIFIED IN TABLE M1507.3.3(1). MANUFACTURERS' FAN FLOW RATINGS SHALL BE DETERMINED ACCORDING TO HVI 916 OR AMCA 210. M1507.3.4.2 FAN NOISE. WHOLE -HOUSE FANS LOCATED 4 FEET OR LESS FROM THE INTERIOR GRILLE SHALL HAVE A SONE RATING OF 1.0 OR LESS MEASURED AT 0.1 INCHES WATER GAUGE. MANUFACTURER'S NOISE RATINGS SHALL BE DETERMINED AS PER HVI 915 (MARCH 2O09). REMOTELY MOUNTED FANS SHALL BE ACOUSTICALLY ISOLATED FROM THE STRUCTURAL ELEMENTS OF THE BUILDING AND FROM ATTACHED DUCT WORK USING INSULATED FLEXIBLE DUCT OR OTHER APPROVED MATERIAL. M1507.3.4.3 FAN CONTROLS. THE WHOLE -HOUSE VENTILATION FAN SHALL MEET THE REQUIREMENTS OF SECTION M1507.3.2 AND M1507.3.2.1. M1507.3.4.4 OUTDOOR AIR INLETS. OUTDOOR AIR SHALL BE DISTRIBUTED TO EACH HABITABLE SPACE BY INDIVIDUAL OUTDOOR AIR INLETS. WHERE OUTDOOR AIR SUPPLIES ARE SEPARATED FROM EXHAUST POINTS BY DOORS, PROVISIONS SHALL BE MADE TO ENSURE AIR FLOW BY INSTALLATION OF DISTRIBUTION DUCTS, UNDERCUTTING DOORS, INSTALLATION OF GRILLES, TRANSOMS, OR SIMILAR MEANS. DOORS SHALL BE UNDERCUT TO A MINIMUM OF 1/2 INCH ABOVE THE SURFACE OF THE FINISH FLOOR COVERING. INDIVIDUAL ROOM OUTDOOR AIR INLETS SHALL: 1. HAVE CONTROLLABLE AND SECURE OPENINGS; 2. BE SLEEVED OR OTHERWISE DESIGNED SO AS NOT TO COMPROMISE THE THERMAL PROPERTIES OF THE WALL OR WINDOW IN WHICH THEY ARE PLACED; 3. PROVIDE NOT LESS THAN 4 SQUARE INCHES OF NET FREE AREA OF OPENING FOR EACH HABITABLE SPACE. ANY INLET OR COMBINATION OF INLETS WHICH PROVIDE 10 CFM AT 10 PASCALS ARE DEEMED EQUIVALENT TO 4 SQUARE INCHES NET FREE AREA. INLETS SHALL BE SCREENED OR OTHERWISE PROTECTED FROM ENTRY BY LEAVES OR OTHER MATERIAL. OUTDOOR AIR INLETS SHALL BE LOCATED SO AS NOT TO TAKE AIR FROM THE FOLLOWING AREAS: 1. CLOSER THAN 10 FEET FROM AN APPLIANCE VENT OUTLET, UNLESS SUCH VENT OUTLET IS 3 FEET ABOVE THE OUTDOOR AIR INLET. 2. WHERE IT WILL PICK UP OBJECTIONABLE ODORS, FUMES OR FLAMMABLE VAPORS. 3. A HAZARDOUS OR UNSANITARY LOCATION. 4. A ROOM OR SPACE HAVING ANY FUEL -BURNING APPLIANCES THEREIN. 5. CLOSER THAN 10 FEET FROM A VENT OPENING OF A PLUMBING DRAINAGE SYSTEM UNLESS THE VENT OPENING IS AT LEAST 3 FEET ABOVE THE AIR INLET. 6. ATTIC, CRAWL SPACES, OR GARAGES. TABLE 1507.3.3 (1) CONTINUOUS WHOLE HOUSE MECHANICAL VENTILATION SYSTEM AIRFLOW RATES FLOOR AREA BEDROOMS (SQ. FT.) 0-1 2-3 4-5 6-7 >7 < 1500 30 45 60 75 90 (IN CFM's) 1501-3000 45 60 75 90 105 120 3001-4500 60 75 90 105 4501-6000 75 90 105 120 135 6001-7500 >7500 90 105 120 135 135 150 150 165 105 120 TABLE 1507.3.3 (2) INTERMITTENT WHOLE HOUSE MECHANICAL VENTILATION RATE FACTORS RUN-TIME PERCENTAGE IN EACH 4-HOUR SEGMENT 25% 33% 50% 66% 75% 100% FACTOR 4 3 2 1.5 1.3 1.0 THIS PLAN USES AN INTERMITTENT WHOLE HOUSE VENTILATION SYSTEM WITH TIMER(s). TOTAL HEATED FLOOR AREA = 798 SQ. FT. BEDROOMS = 1 WHOLE HOUSE VENTILATION SIZE = 30 CFM X 4 (25% PER 4-HOUR) = 120 TOTAL CFM FAN(s) SIZE. INTEGRATED FURNACE OUTSIDE AIR INTAKE WITH EXHAUST FANS AS NOTED IN PLAN. MULTIPLE WHOLE HOUSE VENTILATION FANS TO BE INTERCONNECTED TO OPERATE SIMULTANEOUSLY. 2018 WASHINGTON STATE ENERGY CODE MISC. ENERGY CODE NOTES A permanent certificate shall be completed and posted on or within three feet of the electrical distribution panel by the builder or registered design professional. The certificate shall be completed by the builder or registered design professional and shall not cover or obstruct the visibility of the circuit directory label, service disconnect label or other required labels. The certificate shall list the predominant R-values of insulation installed in or on ceiling/roof, walls, foundation (slab, below -grade wall, and/or floor) and ducts outside conditioned spaces; U-factors for fenestration and the solar heat gain coefficient (SHGC) of fenestration, and the results from any required duct system and building envelope air leakage testing done on the building. Where there is more than one value for each component, the certificate shall list the value covering the largest area. The certificate shall list the types and efficiencies of heating, cooling and service water heating equipment. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour. Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g. (50 Pascals).Where required by the code official, testing shall be conducted by an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. Where the primary heating system is a forced -air furnace, at least one thermostat per dwelling unit shall be capable of controlling the heating and cooling system on a daily schedule to maintain different temperature set points at different times of the day. Specifics and Exceptions see SEC. ALL DUCTWORK SHALL BE SEALED AND TESTED PER R403.2.2. WINDOW AND DOOR HEADERS SHALL BE INSULATED WITH R-10 RIGID INSULATION EXCEPT IN SITUATIONS WHERE STRUCTURAL BEAM SIZE REQUIREMENTS OVERRIDE. ALL APPLIANCES SHALL BE U.L. LISTED. WHOLE HOUSE FANS Whole house ventilation fans shall be installed so as to run simultaniously. EXHAUSTFANS Exhaust fans to terminate at building exterior with clearances per SRC M1506.2 (min. 3 ft to openings) and for clothes dryer vent terminations to be per M1502.3 (3 ft to bldg. openings). ALL FENESTRATION SHALL BE NFRC CERTIFIED. 2x6 TOP PLATES W.B. 3ID R-10 INSULATION kLLED IN CAVITY BETWEEN ER AND INTERIOR G.W.B. ER PER PLAN _OW, FINISH & TRIMS PER MISC. DETAILS HEADER INSULATION 1 1/2" = V-0" PRESCRIPTIVE ENERGY CODE COMPLIANCE 2018 Washington State Energy Code - Residential Prescriptive Energy Code Compliance for All Climate Zones in Washington Single Family - New & Additions (effective February 1, 2021) Version 1.0 These requirements apply to all IRC building types, including detached one- and two-family dwellings and multiple single-family dwellings (townhouses). Project Information Contact Information TOLLEFSON A.D.U. LORI TOLLEFSON & PAUL WATKINS Instructions: This single-family project will use the requirements of the Prescriptive Path below and incorporate the minimum values listed. Based on the size of the structure, the appropriate number of additional credits are checked as chosen by the permit applicant. Provide all information from the following tables as building permit drawings: Table R402.1- Insulation and Fenestration Requirements by Component, Table R406.2 - Fuel Normalization Credits and 406.3 - Energy Credits. Authorized Representative I I Date All Climate Zones (Table R402.1.1) R-Value a U-Factor a Fenestration U-Factor b n/a 0.30 Skylight U-Factor b n/a 0.50 Glazed Fenestration SHGC 1,e n/a n/a Ceiling a 49 0.026 Wood Frame Wall 9,1 21 int 0.056 Floor 30 0.029 Below Grade Wall c,b 10/15/21 int+TB 0.042 Slab d,fR-Value & Depth 10, 2 ft n/a R-values are minimums. U-factors and SHGC are maximums. When insulation is installed in a cavity that is less a than the label or design thickness of the insulation, the compressed R-value of the insulation from Appendix Table A101.4 shall not be less than the R-value specified in the table. The fenestration U-factor column excludes skylights. b "10/15/21 +5TB" means R-10 continuous insulation on the exterior of the wall, or R-15 continuous insulation on the interior of the wall, or R-21 cavity insulation plus a thermal break between the slab and the basement wall at c the interior of the basement wall. "10/15/21 +5TB" shall be permitted to be met with R-13 cavity insulation on the interior of the basement wall plus R-5 continuous insulation on the interior or exterior of the wall. "5TB" means R-5 thermal break between floor slab and basement wall. R-10 continuous insulation is required under heated slab on grade floors. See Section R402.2.9.1. d For single rafter- orjoist-vaulted ceilings, the insulation may be reduced to R-38 if the full insulation depth e extends over the top plate of the exterior wall. R-7.5 continuous insulation installed over an existing slab is deemed to be equivalent to the required perimeter f slab insulation when applied to existing slabs complying with Section R503.1.1. If foam plastic is used, it shall meet the requirements for thermal barriers protecting foam plastics. For log structures developed in compliance with Standard ICC 400, log walls shall meet the requirements for g climate zone 5 of ICC 400. Int. (intermediate framing) denotes framing and insulation as described in Section A103.2.2 including standard h framing 16 inches on center, 78% of the wall cavity insulated and headers insulated with a minimum of R-10 insulation. Prescriptive Path - Single Family 2018 Washington State Energy Code-R 1 FENENSTRATION CALCULATIONS VERTICAL GLAZING 171 SF LESS EXEMPT GLAZING -00 SF PLUS GLAZED DOORS 24 SF PLUS OTHER EXTERIOR DOORS 24 SF TOTAL FENESTRATION: 219 SF NOTE: SEE SHEET A5 FOR ADDITIONAL INSULATION LOCATIONS AND DETAILS. ENERGY CREDITS OPTIONS DESCRIPTION HEATING For heating system based on electric resistance with a ductless OPTION 4 mini -split heat pump system in accordance with Section R403.7.1 including the exception. Ductless mini -split heat pump system, zonal control: In homes ENERGY where the primary space heating system is zonal electric OPTION 3.4 heating, a ductless mini -split heat pump system with a minimum HSPF of 10.0 shall be installed and provide heating to the largest zone of the housing unit. To qualify to claim this credit, the building permit drawings shall specify the option being selected and shall specify the heating equipment type and the minimum equipment efficiency. ENERGY Water heating system shall include one of the following: OPTION 5.3 Energy Star rated gas or propane water heater with a minimum UEF of 0.91 TOTAL CREDITS CREDIT 0.5 1.5 in 3.0 2018 Washington State Energy Code - Residential Prescriptive Energy Code Compliance for All Climate Zones in Washington Single Family - New & Additions (effective February 1, 2021) Each dwelling unit in a residential building shall comply with sufficient options from Table R406.2 (fuel normalization credits) and Table 406.3 (energy credits) to achieve the following minimum number of credits. To claim this credit, the building permit drawings shall specify the option selected and the maximum tested building air leakage, and show the qualifying ventilation system and its control sequence of operation. 1. Small Dwelling Unit: Dwelling units less than 1,500 sf in conditioned floor area with less than 300 sf of fenestration area. Additions to existing building that are greater than 500 sf of heated floor area but less than 1,500 sf. 2. Medium Dwelling Unit: 6 credits All dwelling units that are not included in #1 or #3 3. Large Dwelling Unit: credits Dwelling units exceeding 5,000 sf of conditioned floor area 4. Additions less than 500 square feet: 1.5 credits All other additions shall meet 1-3 above Before selecting your credits on this Summary table, review the details in Table 406.3 (Single Family), on page 4. Summary of Table R406.2 Heating Options Fuel Normalization Descriptions Credits - select ONE heating option User Notes 1 Combustion heating minimum NAECAb 0.0 ❑ 2 Heat pump` 1.0 ❑ 3 Electric resistance heat only - furnace or zonal -1.0 ❑ 4 DHP with zonal electric resistance per option 3.4 0.5 Il 5 All other heating systems -1.0 ❑ Energy Options p Energy Credit Option Descriptions offlTMMM1NM l®0 00M®DO Efficient Building Envelope Efficient Building Envelope Credits - select ONE energy option from each category 0.5 ❑ 1.1 1.2 1.0 ❑ 1.3 0.5 ❑ 1.4 Efficient Building Envelope 1.0 ❑ 1.5 Efficient Building Envelope 2.0 ❑ 1.6 Efficient Building Envelope 3.0 ❑ 1.7 Efficient Building Envelope ❑ 0.5 ❑ 2.1 Air Leakage Control and Efficient Ventilation 0.5 ❑ 2.2 Air Leakage Control and Efficient Ventilation 1.0 ❑ 2.3 Air Leakage Control and Efficient Ventilation 1.5 ❑ 2.4 Li Air Leakage Control and Efficient Ventilation 2.0 ❑ 3. la High Efficiency HVAC 1.0 ❑ 3.2 High Efficiency HVAC 1.0 ❑ 3.31 High Efficiency HVAC 1.5 ❑ 3.4 High Efficiency HVAC 1.5 17 3.5 High Efficiency HVAC 1.5 ❑ 3.6a High Efficiency HVAC 2.0 ❑ 4.1 High Efficiency HVAC Distribution System 0.5 ❑ 4.2 High Efficiency HVAC Distribution System 1.0 ❑ Prescriptive Path - Single Family 2018 Washington State Energy Code-R 2 HEATING SYSTEM SIZE simple meating system size: vvasnington state This heating system sizing calculator is based on the Prescriptive Requirements of the 2018 Washington State Energy Code (WSEC) and ACCA Manuals J and S. This tool will calculate heating loads only. ACCA procedures for sizing cooling systems should be used to determine cooling loads. Please complete the green drop -downs and boxes that are applicable to your project. As you make selections in the drop -downs for each section, some values will be calculated for you. If you do not see the selection you need in the drop -down options, please contact the WSU Energy Program at energycode@energy.wsu.edu or (360) 956-2042 for assistance. Project Information Contact Information TOLLEFSON I LORI TOLLEFSON & PAUL WATKINS Heating System Type: O All Omer systems .O Heat Pump To see detailed instructions for each section, place your cursor on the word "Instructions" Design Temperature Instructions Design Temperature Difference (AT) 46 Edmonds T = Indoor (70 degrees) - Outdoor Design Temp Area of Building Conditioned Floor Area Instructions Conditioned Floor Area (sq ft) 798 Average Ceiling Height Conditioned Volume Instructions Average Ceiling Height (ft) 9.1 7,262 Glazing and Doors U-Factor X Area = UA Instructions u-o.so 0.300 219 65.70 Skylights U-Factor X Area UA Instructions 0.50 12 6.00 Insulation Attic U-Factor X Area UA -tions R 49 0.026 798 20.75 Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA 'nstructions No Vaulted Ceilings in this project. Above Grade Walls (see Figure 1) U-Factor X Area UA Instruction` R-211ntermediate 0.056 1,115 62.44 Floors U-Factor X Area UA ctions No Floors above unconditioned spaces. � Below Grade Walls (see Figure 1) U-Factor X Area UA Instructions No Below Grade Walls in this project 0.028 00 Slab Below Grade (see Figure 1) F-Factor X Length UA LNo in 0.303 0� --- Slab Below Grade this project Slab on Grade (see Figure 1) F-Factor X Length UA Instructions A 0.360 132 47.52 R-10 Fully Insulated Location of Ducts Instructions Duct Leakage Coefficient No Ducts i 1.00 Figure 1. Above Grade Sum of UA 202.41 Envelope Heat Load 9,311 Btu / Hour Sum of UA x AT Air Leakage Heat Load 3,608 Btu / Hour Volume x 0.6 x AT x 0.018 Building Design Heat Load 12,918 Btu / Hour Air leakage + envelope heat loss Building and Duct Heat Load 12,918 Btu / Hour Ducts in unconditioned space: sum of buildino heat loss x 1.10 Ducts in conditioned space: sum of building heat loss x 1 Maximum Heat Equipment Output 16,148 Btu / Hour Buildino and duct heat loss x 1.40 for forced air furnace Buildino and duct heat loss x 1.25 for heat pump 2018 Washington State Energy Code - Residential Prescriptive Energy Code Compliance for All Climate Zones in Washington Single Family- New & Additions (effective February 1, 2021) Summary of Table R406.2 (cont.) Energy Credits - select ONE Energy Credit Option Descriptions (cont.) energy option from User Notes Options each category d 5.1d Efficient Water Heating 0.5 ❑ 5.2 Efficient Water Heating 0.5 ❑ 5.3 Efficient Water Heating 1.0 5.4 Efficient Water Heating 1.5 ❑ 5.5 Efficient Water Heating 2.0 ❑ 5.6 Efficient Water Heating 2.5 ❑ 6. le Renewable Electric Energy (3 credits max) 1.0 Q 7.1 Appliance Package 0.5 ❑ Total Credits 3.0 Calculate Total I Clear Form J a. An alternative heating source sized at a maximum of 0.5 W/sf (equivalent) of heated floor area or 500 W, whichever is bigger, may be installed in the dwelling unit. b. Equipment listed in Table C403.3.2(4) or C403.3.2(5) c. Equipment listed in Table C403.3.2(1) or C403.3.2(2) d. You cannot select more than one option from any category EXCEPT in category 5. Option 5.1 may be combined with options 5.2 through 5.6. See Table 406.3. e. 1.0 credit for each 1,200 kWh of electrical generation provided annually, up to 3 credits max. See the complete Table R406.2 for all requirements and option descriptions. f. Use the single radiobutton in the upper right of the second column to deselect radiobuttons in that group. Please print only pages 1 through 3 of this worksheet for submission to your building official. Prescriptive Path - Single Family 2018 Washington State Energy Code-R (07101113) RESUB Nov 29 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 3 V Z N cc >_ CD Q Z a> E > O U 1011- Y = way w ,o � O U co e6 ,2 coCDC .. LLJ � F0 ilk a) a) LLJ m 0 LLJ 0- E O \� C N li W JIM U m am -o ya `o Z O C2 N N R 9 N U O O 2 @ m- .- W N- T (n IN N 3: J N N E T O. @ N C o Z-o 1102Eammyomno- N a m O.U.@ O L 1—O 0 U L OF O u, O O J O C 02 - Fa CCZLLOZOQ y �:20 a,- or.. m m E w o LU 0U JF Joyo. oc0 of o>coU .y�3 nm�mo UN o LUdo..@ONO w mU 2o a,Q5 E�mb_d Zo Z 0 W Z o N Z o J Co W a W 0 3 N LU z p ZW uJ 0 uJ uJ II- LU v, U zVUJ Q U V � w w w Z Q M CIO Q O ¢ � a) irs 0 c 0 Ln 0 Z PROJECT NO. 210404 DESIGNED BY TL DRAWN BY TL & RM CHECKED BY TL SHEET NO. A2 PRINT DATE 8/5/2021 12:55:41 PM ELEVATION NOTES PROVIDE METAL FLASHING OVER TOPS OF WINDOWS AND TOPS OF TRIMS DIRECTLY EXPOSED TO WEATHER. ROOFING MATERIAL, SIDING AND FLASHING SHALL BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS, INDUSTRY STANDARDS AND PER I.R.C. PORCHES, BALCONIES, RAMPS OR RAISED SURFACES LOCATED MORE THAN 30" ABOVE THE FLOOR OR GRADE BELOW SHALL HAVE GUARDS NOT LESS THAN 36" IN HEIGHT. OPEN SIDE OF STAIRS WITH A TOTAL RISE OF MORE THAN 30" SHALL HAVE GUARDS NOT LESS THAN 34" IN HEIGHT MEASURED VERTICALLY FROM THE NOSING OF THE TREADS. INTERMEDIATE RAILS OR ORNAMENTAL CLOSURES SHALL BE SPACED SUCH THAT A 4" SPHERE CANNOT PASS THROUGH. THE TRIANGLE OPENINGS FORMED BY THE RISER, TREAD, AND BOTTOM OF RAIL SHALL BE SUCH THAT A 6" SPHERE CANNOT PASS THROUGH. EXTERIOR STAIRS SHALL BE NOT LESS THAN 36" WIDE. HANDRAILS SHALL NOT PROJECT MORE THAN 45, ON EITHER SIDE OF THE STAIRWAY AND MIN. CLEAR WIDTH AT OR BELOW THE HANDRAIL SHALL NOT BE LESS THAN 31.5". MAX. RISER HEIGHT IS 7 3/4". MIN. TREAD DEPTH SHALL BE 10". A LANDING IS REQUIRED AT TOP AND BOTTOM OF EACH STAIRWAY. SITE ADDRESS SHALL BE VISIBLE AND LEGIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY. NUMBERS SHALL CONTRAST WITH BACKGROUND, BE ARABIC NUMBERS OR ALPHABETICAL LETTERS, BE A MIN. OF 4" IN HEIGHT WITH A MIN. STROKE WIDTH OF 1/2". (R319.1) OrainEd>�e '° strip ° WeatherSeal trowel -applied membrane Step flashing taped and sealed Kick -out flashing Kick -out and fascia taped and sealed KICKOUT FLASHING �DETAIL -III III III III III III APPROVED BY PLANNING ELEVATION KEYNOTES KEY VALUE KEYNOTE TEXT 39 40+ YEAR PRESIDENTIAL RANDOM CUT ARCHITECTURAL COMPOSITION ROOFING 41 CONTINUOUS ALUMINUM GUTTER ON 5/4x6 FASCIA 42 BOARD AND BATTON: 1x3 BATTONS @ 16" O.C. ON HARDI-BOARD OR EQUIV. SMOOTH FACED BOARDS 44 FASCIA: 1x3 ON 5/48 WHITE WOOD (TYPICAL AT GABLE ENDS) 55 5/4x8 CEDAR OR WHITE WOOD TRIM PER BUILDER SPECIFICATIONS. 66 WINDOW WRAP: 5/44 SIDE RAILS w/ 2x6 TOP RAIL AND 2x3 DRIP SILL OVER 5/4x6 TRIM. PROVIDE HEAD FLASHING OVER ALL WINDOWS NOT UNDER EAVES AND/OR EXPOSED TO WEATHER. DECORATIVE 4x KNEE BRACE 68 71 BOX FRAME POST BASE AND WHITE WOOD TRIMS o/ STRUCTURAL POST PER PLAN 73 5/4" CEDAR OR WHITE WOOD WRAPS o/ STRUCTURAL POST PER PLAN 74 36" HIGH WOOD RAIL AND CAP PER PLAN. PICKETS SPACED SUCH THAT A 4" SPHERE CANNOT PASS THROUGH 76 P.T. DECK POSTS, JOISTS AND BEAMS PER PLAN 83 PROVIDE 6" MINIMUM EARTH/WOOD CONTACT TEMP. GL. LOCKING DEADBOLD AT ENTRY DOOR 84 85 86 CONCRETE LANDING AND STEPS PER I.R.C./I.B.C. 5 EAST ELEVATION 1/4" = 1'-0" Ak TOP -of _Ridc�e 115-23/8" 1ST FLOOR PLAT 109' -1 1 /8" e Average Gra 108'-9" 1ST FLOOR 0'-0" Max Height L 133' - 9" _F' WEST ELEVATION 1/4" = 1'-0" NORTH ELEVATION 1/4" = 1'-0" 1f Ridge � ' - 2 3/8" -710 PLATE ' - 1 1 /8" e Grade 108'-9" V FLOOR 100'-0" RESUB Nov 29 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT V z N C) 0) z QE Q U IL Y = �, way w a O "�� U J LO � 0) M(O.O z ooN` Lu im 0 0) Lu m 0 Lu n 2 H E O V N ty N Z N .d.. C L_ N N C C U C > 4q N N ?i J N L t6 T O. R— C p Z J 0 0 COL @ N N O N O- _ O E a IL Fa O .� R` ti C C UL. O .O N C O U' O U C N L '= N U E N a W O j E'6 W H O a 0 � 2 C N N O a 0 W U o c4 w o V° o c c_ 3 S N y O J J H C m o w o O H a16 m 0" `o w 0,05 N U a2. "O E N N L, C Zao"m dd OHE`°°� H Z Lu Z o N Z o J o0 Lu a Lu 0 � N IW z � o z Lu0 0 Lu Lu W N H Lu Lu zV ww V w o Z0 oM Q O ¢ � 43) 0 0 .N Of 0 z PROJECT NO. 210404 DESIGNED BY TL DRAWN BY TL & RM CHECKED BY TL SHEET NO. A3 PRINT DATE 9/17/2021 10:03:09 AM KEYNOTE SCHELDULE KEY VALUE TEXT 02 LANDINGS: THERE SHALL BE A FLOOR OR LANDING AT EACH SIDE OF EACH EXTERIOR DOOR. LANDING OR FLOOR SHALL BE A MAX. 1.5" LOWER THAN THE TOP OF THE THRESHOLD; 7 3/4" IS PERMITTED AT EXTERIOR DOORS THAT DO NOT SWING OVER THE LANDING. MAX. LANDING SLOPE IS 1/4:12. (R311.3.1 & 311.3.2) 04 COOKING APPLIANCES: HOUSHOLD COOKING APPLIANCES SHALL BE LISTED AND LABELED AND INSTALLED IN ACCORDANCE WITH MANUF. SPECS. RANGE HOOD SHALL HAVE LIGHT & 100 CFM MIN. EXHAUST FAN AND BE VENTED TO OUTSIDE WALL. EXAHUST HOOD SYSTEMS IN EXCESS OF 400 CFM SHALL BE PROVIDED WITH MAKE UP AIR IN THE AMOUNT EQUIV. TO THE EXHAUST RATE. (M 1503) 10 DRYER: VENT TO OUTSIDE AND PER MANUFACTURER SPECICATIONS. DUCTS SHALL HAVE A SMOOTH INTERIOR FINISH AND CONSTRUCTED OF METAL. MAX. DUCT LENGTH PER TABLE M1502.4.4.1 OR M1502.4.4.2. (M1502) 11 TYPICAL EXTERIOR WALL: SIDING o/ INFILTRATION BARRIER o/ EXTERIOR SHEATHING PER STRUCTURAL PLANS o/ 2X6 STUDS @ 16" O.C. w/ R-21 BATT INSULATION AND 1/2" MIN. GWB AT INSIDE FACE w/ P.V.A. PRIMER. 14 ATTIC ACCESS: MIN. 22"X30" AND REQUIRED AT AREAS GREATER THAN 30 SQ. FT. AND VERTICAL HEIGHT OF 30" OR GREATER. (R807.1) SEE M1305.1.3 FOR ADDITIONAL REQUIREMENTS WHERE MECHANICAL EQUIPMENT IS LOCATED IN ATTIC. 17 CLOSET ROD w/ VINYL COATED WIRE SHELF 18 CLOSET SHELVING AND DRAWER ORGANIZERS PER BUILDER SPECS. 19 TEMP. GLASS DOOR 28 HYDROBLOK OR EQUIV. SHOWER PAN w/ TILE SURROUND. 2) 13/H RU - 44 POST PER STRUCTURAL PLANS ATTACHED TO RIM AND BLOCKING SO AS TO COUNTER A 200# FORCE - SPACED DECKING PER PLAN P.T. BLOCK P.T. JOISTS PER STRUCTURAL PLAN - 2X6 ARCH. RADIUS CAP OR EQUIV. 1x4 ARCH. TRIM 2x2 PICKETS @ 5.5" O.C. SO THAT A 4" SPHERE - CANNOT PASS THROUGH. o z 7 M � 1x4 ARCH. TRIM CONNECTION DETAILS PER STRUCTURALPLANS (SEE DETAIL 7/S5) - P.T. RIM BLOCKING PER STRUCTURAL PLANS P.T. BEAM PER STRUCTURAL PLAN DECK POST DETAIL 5 El � O 1 A6 N N io 3 N N 2 1 O I'1 2' -10" 0 I U I B C D 37'-6" 14'-0" 14'-2" 6'-6" T-0" 100 CFM WHOLE HOUSE FAN WITH TIMER. EMERGENCY EG ESS _ 2 3/4" (min. 60 cfm per code) WINDOW PER CODE: 2650 CASEMENT 11 2' - 3 1/2" - TEMP. GL. SKYLIGH 10 P77771- OPTIONAL ` -- SEAT AT SHOWER 14'-0" 18 HEAT PUMP HEAD — ROLL -IN TANLESS H.W.S. 28 SHOWER- --PER BUILDER TIMER BATH/ LOCATION C° I CONTROLS 14 L J 19 � 10 D2 D8 17 6 1/4" 00 BEDROOM ` CA (NETS BY OTHERS N ZI \x Z CV I � I � I � III LIVING RM. C OPTIONAL VAULTED CEILING w/ SCISSIOR TRUSSES. - HEAT PUMP HEAD �- 00 PANTR - ----- STACK WA/ in OO 0 DRYER (V.T.O.) S.D. m 2x6 WALL OD5 �O 0 D so CFM Q, c.o. s.D. ---- WATER SHUT OFF 1 REFRI .ELEC_ V.T.o. _ SPACE PAN Zfl (SHUT OFF) ' MUD R 3' - 6" 2' -10" EXIST. 3'- 0" T - 1" 2' - 0" EIASEMENT A TEMP. GL. SKYLIGHT00 D1 (vei ify location) I I EXISTING BASEMENT 850 S.F. OUP O S.D. - CONTRACTOR TO I �'� co IKITCIIH EN 02 N -- SEWER LINE (LOCATION T.B.D.) o CABINETS BY ��, BENCH & M' L OTHERS COAT HOOKS - NEW GRINDER PUMP PER CONTRACTOR. I �'--_------ - ® EXACT LOCATION T.B.D. D.W. EXISTING VERIFY EXISTING SMOKE DETECTORS AND MODIFY AS NEEDED SO AS TO BE INTERCONNECTED WITH OTHER DETECTORS INCLUDING THE NEW A.D.U. ifl H W T WATER SHUT OFF TO MAIN HOUSE - CONTRACTOR 0 O_ - TO VERIFY. Zo COVE ED PORCH 2 REPLACE EXSI TING A.D.U. ENTRANCE 2'- 8 3/4" DECK AND LANDING I 12'-6" 6-111/2" 12'-61/2" 6'-6" .00 Ilu Ih PAVER STONE PATIO II - IIII IIII IIII-----__ IIII IIII � HP-- IIII II II II II II II II II II II II II II II II II II II U II II II II II II REPLACE EXSITING DECK AND LANDING 1ST FLOOR - NEW ADU. 1/4" = 1'-0" WINDOW SCHEDULE SYM. NO. WIDTH HEIGHT AREA WINDOW TYPE U-VALUE COMMENTS 1 ST FLOOR 1 6'- 0" 5' - 0" 30 SF DOUBLE SLIDER 0.30 3 7'- 0" 4' - 6" 32 SF DOUBLE SLIDER 0.30 4 2'- 6" 4' - 6" 11 SF CASEMENT - SINGLE 0.30 5 2'- 6" 4' - 6" 11 SF CASEMENT - SINGLE 0.30 6 2' - 6" 4' - 6" 11 SF CASEMENT - SINGLE 0.30 7 3'- 6" 5' - 0" 18 SF CASEMENT - SINGLE 0.30 8 3'- 6" 5' - 0" 18 SF CASEMENT - SINGLE 0.30 9 3'- 6" 5' - 0" 18 SF CASEMENT - SINGLE 0.30 10 2'- 0" 6' - 0" 12 SF PICTURE (FIXED) 0.30 TEMP. GLASS / FROSTED GLASS 1 ST FLOOR PLATE 11 12'-0" 3' - 0" 6 SF SKYLIGHT 0.50 TEMP. GLASS 12 12'-0" 3' - 0" 6 SF SKYLIGHT 0.50 TEMP. GLASS Grand total 172 SF 8'-0" I DECK CONSTRUCTION TO CONSIST OF APPROVED .WOODS OF NATURAL RESISTANCE TO DECAY OR I BE TREATED WOOD AND LABELED ACCORDINGLY. ■ I RC R317.1 & R317.2 • SCALE BAR 0' 2' 4' 8' I E Hardware and fasteners in contact with I preservative -treated wood shall be of ■ ' hot -dipped zinc galvanized steel, I o I stainless steel, silicon bronze or copper. ■ In the absence of manufacturer's recommendations Ia minimum of ASTM A 653 type G185 zinc -coated I galvanized steel, or equivalent, shall be used. ■ L IRC R317.3.1 IBC 2304.10.5.1 I DOOR SCHEDULE SYM. NO. 1 ST FLOOR WIDTH HEIGHT DOOR TYPE COMMENTS D1 3' - 0" 8'- 0" SINGLE STORE DOOR (TEMP.) TEMP. GL. (U=0.28) D2 5' - 0" 6'- 8" BI-PASS CLOSET DOOR D3 5' - 0" 6'- 8" BI-PASS CLOSET DOOR D4 3' - 0" 8'- 0" SINGLE ENTRY ENTRY DOOR (0.28 TEMP. GLASS) D5 3'-0" 6' - 8" SINGLE POCKET D6 3' - 4" 6' - 8" SINGLE POCKET D7 4' - 0" 6'- 8" BI-FOLD 4 PANEL CLOSET DOOR D8 2' -10" 6'- 8" SINGLE POCKET 16' RESUB Nov 29 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT V Z N co 00 0) Z QE Q � 8 IL Y 2 rn wa'w w ,n aa) ";� O JL� U �O � (o CD00 Z N` LU �2 V Ix 00 aa) LU M 0 LU a H E 4) k Z 32 c3woo �L. N N ?� J y L t6 ), O. N C O o Z o� c° t y a m N o � o a�i cram . o�H06 1 5Edc`o w° C C U O� :6 N.L. y° a0 o y �,'o o 6- m 16 m 0 L%l EL °° p QoW�UUQT OJJ H &0N° W OCoz C o E m d H Z W Z o N J Z o o0 LU W 0 � N LU z Z p LU0 0 LU LU W N H LU LU zV w V")� w 0 � Q Z O O � M ¢ � M 000 -- N N N C14 to N � N E c m E 0 .N 0 � a� c N f0 o 0 co > a� 0 Z PROJECT NO. 210404 DESIGNED BY TL DRAWN BY TL & RM CHECKED BY TL SHEET NO. PRINT DATE 1 1 /21 /2021 3:03:55 PM Q NEW BRtEZE BELOW i EXISTING PW R. METER AND SHUTOFF—� � IIIIIIIII' OFFICE REPLACEMENT DECK (SEE 1 ST FLOOR PLAN, SHEET A4) EXISTING MAIN FLOOR 864 S.F. LIVING RM. KITCHEN DINING EXIST. 1/4" = 1'-0" MAIN FLOOR EXISTING HOUSE PLAN - FOR REFERENCE ONLY EXISTING 2ND FLOOR 672 S.F. PER SNO. CO.RECORDS PRIMARY BEDROOM 0 S.D. / D S.D. HALL CONTRACTOR TO VERIFY EXISTING SMOKE DETECTORS AND MODIFY AS NEEDED SO AS TO BE INTERCONNECTED WITH OTHER DETECTORS INCLUDING THE NEW A.D.U. BATH GUEST BEDROOM EXIST. 2ND FLOOR 1/4" = 1'-0" RESUB Nov 29 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT V z N co 0) z Q E Q � U IL Y = u1aw a O U J �LO � (M (O z 00N` Lu � N im 0 U7 Lu m J 0 Lu n E 0 v c �1 4) Gig 4i W 6 c Z N C L_ N N C U C w E .L.. O N E T a y O o Z o o .0. y a m N o aci n o- c�amc'� OQ�a �J QLLJ aH y0C13n'v0U �-1 cicc°c°i E SVrnO U Cod�; y� r O C EOWEV NN QW O q O Q O U Q O-O NaU W O U a N 'O E N U1 L O C Zo.°"gym d: oHE`°°� I- z W Z o N Z o J o0 W a W 0 � N p W z p zW 0 Lu Lu W to w to LL. W zLU V (L w w w O Q O cu cu c 0 .N N 0 z PROJECT NO. 210404 DESIGNED BY TL DRAWN BY TL & RM CHECKED BY TL SHEET NO. A5 PRINT DATE 11 /21 /2021 2:41:13 PM A B C D 12'-6" 18'-6" 6'-6" 12 12 81 18 ROOFING PER ELEVATIONS o/ 30# FELT OVER SHEATHING PER STRUCTURAL o/ MANUF. TRUSSES PER PLAN 1" AIR SPACE w/ BAFFLE. EXTENDED 24" ABOVE INSULATION R-49 BATT OR BLOWN INSUL. THROUGHOUT ATTIC AREA FASCIA BOARD PER ELEVATIONS SOFFIT PER ELEVATIONS MAIN PLATE FRAMING MEMBER ATTACHED TO TOP PLATES PER STRUCTURAL — — — — — — (2) 2x_ TOP PLATES PER STRUCTURAL PLANS. STAGGER JOINTS A MIN. OF 48"0.C. I HEADER PER STRUCTURAL 2" RIGID R-10 INSULATION INSTALLED IN CAVITY BETWEEN HEADER & INTERIOR G.W.B. WINDOW ADO /2 G.W.B. PROVED LIVING RM. KITCHEN MUD RM. P.V.A. VAPOR RETARDER R-21 BATT INSULATION (IN FULL WALL CAVITY) 2x6 STUDS @16" O.C. (U.N.O. IN STRUCTURAL) EXTERIOR FINISH PER ELEVATION o/ 15# BUILDING PAPER OR APPROVED AIR INFILTRATION BARRIER o/ SHEATHING PER STRUCTURALPLANS PLANT ON 2x4 WALL 4" CONC. SLAB o/ 2" RIGID INSUL. I w/ THERMAL BRAKE o/ COMPACTED GRANULAR FILL I METAL FLASHING CAULKING/ SEALANT BEAD 4" CONC. SLAB o/ COMPACTED GRANULAR FILL MAIN FLOOR P.T. 2x BASE PLATE PER mA7 _ TU17L l� wr d A ANCHOR BOLTS PER — — — — — — — — — — — — —— — — — — — — — — — — — — — — — — — — — — — — — —a — — — — — — — — — — — — — — —da --------- I a SHEAR WALL SCHEDULE- 4" TIGHTLINE DRAIN WHERE REO'D FOUNDATION WALL SIZE AND d,a REINFORCING PER `? STRUCTURALPLANS ° d 4" PERF. FT'G DRAIN. WRAP IN FILTER � v :v ✓ �/i FABRIC w/ GRAVEL OVER FABRIC �A/.�:� FOOTING SIZE AND REINFORCING ad a PER STRUCTURAL PLANS (T� BUILDING SECTION � SCALE: 1/2" = 1'-0" RESUB Nov 29 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT I— Z W z V o z N CD 00 W W Q a � N 0 W o Z z Lu W O Lu W W Vy♦ F " w �.. W zV z w w LV w � Z �a o� 0 M Q� O r a w m 0 z PROJECT NO. 210404 DESIGNED BY TL DRAWN BY TL & RM CHECKED BY TL SHEET: A6 PRINT DATE 11/21/2021 2:45 PM GENERAL NOTES All design and construction shall conform to the requirements of the 2018 International Building Code. Contractor shall verify all levels, dimensions and existing conditions in field before proceeding with any construction or demolition. Contractor shall notify the Architect of any discrepancies or field changes Contractor shall be responsible for all safety precautions and the methods, techniques, sequences or procedures required to perform the work. Contractor shall provide adequate shoring and bracing of all structural members, existing construction and soil excavations as required, in a manner suitable to the work sequence. Temporary shoring and bracing shall not be removed until all final connections have been completed in accordance with the drawings and materials have achieved design strength. Foundations walls greater than 4 feet shall not be backfilled until the floor framing and all connections to the floor framing per these details are complete. CHANGES: No changes to these structural drawings are permitted without written consent of the Engineer. Changes will be billed to the client, owner or contractor at the Engineer's hourly rate. SUBMITTALS: Shop drawings shall be submitted to the Architect prior to any fabrication or construction for all the following: Structural steel, steel canopies, glued -laminated members and pre -manufactured wood members. Design drawings and calculations, for pre -manufactured wood trusses and joists shall bear the seal and signature of the Washington State Registered Professional Engineer who is responsible for the design, and shall be submitted to the Architect and Building official for review prior to fabrication. DESIGN LOADS LIVE LOADS: Live loads are determined in accordance with ASCE Ch. 4 L = 40 PSF (Residential) = 60 PSF (Balcony) SNOW LOADS: Snow loads are determined in accordance with ASCE Ch. 7 with the following Factors: Ground Snow Load Pg = 20 psf Ct = 1.0 Ce = 1.0 Roof Snow Load Ps = 25 psf Is = 1.0 WIND LOADS: Wind loads are based on ASCE 7 Ch. 28 (Envelope Procedure) with the following factors: Exposure Category = B Velocity (3 sec) = 100 mph (ult) Kzt = 1.0 Design wind pressured for determining forces on components and cladding are determined in accordance with ASCE 7 Chapter 30. SEISMIC LOADS: Seismic loads are based on the Equivalent Lateral Force Procedure in ASCE 7-10 Section 12.8 with the following factors: Risk Category = II Ss = 1.27 Site Class = D S1 = 0.498 Design Category = D SDS = 0.846 R = 6.5 (wood shear wall) SD1 = 0.598 Ie = 1.0 Cs = 0.130 (ult.) FOUNDATIONS Concrete foundations shall be placed on Bearing Ground defined as follows. Bearing Ground shall be stiff, competent, non -expansive, undisturbed native soil. Where native soil is inadequate for bearing, foundations shall be placed on structural fill mixed and compacted (and scarified if necessary) in accordance with specifications provided by a Washington State licensed Geotechnical Engineer. Prior to construction, the contractor shall verify the Bearing Ground has minimum allowable bearing pressure = 1500 psf. Bottom of footing elevation shall be located at minimum frost depth 18" below top of finished grade unless required otherwise by the Building Official. The contractor shall confirm the minimum frost depth with the Building Official prior to excavation. CONCRETE Concrete work shall comply, in general, with ACI 301 (latest edition) "Specifications for Structural Concrete for Buildings." CONCRETE MIXES: Concrete mixes shall conform ACI 318 Ch. 5. Minimum concrete strength f'c at 28 days shall be as follows: Slab -on -grade, Curbs and Pads - 2000 psi Footings - 2500 psi Walls, Stems - 3000 psi (2500 psi used for structural design) Water/cement ratio shall be measured by weight and shall be based on the total cementitious material. Water/cement ratio shall be determined by the supplier based on strength requirements and shall not exceed 0.55. Water -reducing admixtures may be incorporated in concrete mix designs but shall conform to ASTM C 464, and be used in accordance with the manufacturer's recommendations. CaCI and other water-soluable chloride admixtures shall not be used. REINFORCING STEEL: All reinforcing shall be deformed bar (rebar) with bar diameters specified in these drawings and properties below: All reinforcing unless noted otherwise - ASTM A615, Grade 60 #3 stirrups and ties - ASTM A615, Grade 40 Welded rebar - ASTM A706, Grade 60 Galvanized Welded Wire Fabric - ASTM A165 Reinforcing steel shall be detailed in accordance with ACI 315 "Manual of Standard Practice for Detailing Reinforced Concrete Structures." Reinforcing steel shall be lapped as noted on the drawings. Where lap length is not shown, reinforcing bars shall be lapped as follows: #5 and smaller - 48 bar diameters #6 and larger - 60 bar diameters Minimum concrete cover over reinforcing shall be as follows: Nonstructural Slab -on -grade - Mid -Depth Wall Bars: interior face - 3/4" exposed to earth/weather - 1-1/2" (#5 and smaller) 2" (#6 and larger) Footings: Bottom Bars - 3" (cast against earth) Top Bars - 1-1/2" Side Bars - 2" Provide supports as required for proper alignment and concrete cover around the reinforcement. Consult the CRSI Manual of Standard Practice MSP-1 for specific information. WOOD SAWN LUMBER: Structural sawn lumber shall be kiln dried and be of the species and grade noted below or better: Use Grade Fb(psi) Wall Studs Hem Fir Stud 675 Plates & Planks Hem Fir #2 850 Joists & Rafters Hem Fir #2 850 4x Beams Douglas Fir -Larch #2 900 6x Beams Douglas Fir -Larch #2 875 Posts Douglas Fir -Larch #2 750 2x4 T&G Decking Douglas Fir -Larch Select 1750 All lumber and plywood exposed to weather or water or in contact with concrete, stucco, masonry or other cementitious materials shall be treated with an E.P.A. acceptable wood preservative, such as Alkaline -Copper -Quaternary "ACQ" or Copper Azole "CBA" type A and B. All wood connectors shall be manufactured by Simpson Strong Tie Company (or approved equal), and of the size and type shown on the drawings. All wood connectors in contact with preservative -treated wood shall be Triple Zinc G-185 galvanized (1.85 oz/sq ft coating). MINIMUM WOOD NAILING REQUIREMENTS: Unless otherwise noted on the drawings, typical wood framing shall be fastened as follows. See IBC Table 2304.10.1 for fastener alternatives not shown. Location Min. Nail Quantity/Spacing Type* Beams (built up 2x's) 3" x 0.131" 24" o.c. T&B* FN EF* staggered Blocking -to joists, rafters, trusses 3" x 0.131" 2 each end TN or studs -to top plates 3" x 0.131" 3 TN Bottom plate -to joist, rim joist 3" x 0.131" 12" o.c. FN or blocking -to studs 3" x 0.131" 3 EN Header (built up 2x's) 16d box 12" o.c. T&B FN Header -to studs 3" x 0.131" 4 TN Joist -to supports 3" x 0.131" 3 TN -to rim joist 3" x 0.131" 4 EN Rafter -to supports 3" x 0.131" 4 TN, EN Rim Joist -to sill or blocking 3" x 0.131" 6" o.c. TN Stud -to Stud 3" x 0.131" 12" o.c. FN -to top/bottom plate 3" x 0.131" 4 TN Top plate -to top plate 3" x 0.131" 12" o.c. FN -to studs 3" x 0.131" 3 EN -laps at corners and 3" x 0.131" 3 FN intersections Truss to top plate 3" x 0.131" 4 TN *EN = end nail, FN = face nail, TN = toe nail, EF = "each face", T&B = "top and bottom" RATED SHEATHING: Wood structural panels shall bear the APA trademark of the American Plywood Association. Sheathing shall be as follows: Shear Wall Shtg APA rated 7/16" 32/16 C-D INT with Exterior Glue (CDX or OSB) Roof Shtg APA rated 15/32" 32/16 C-D INT with Exterior Glue (CDX or OSB) Sub Floor Shtg APA rated 3/4" 48/24 T&G C-D INT with Exterior Glue Sheathing shall be orientated over the supports as shown on the drawings. Shear wall sheathing shall be blocked at all panel edges as shown in the shear wall schedule. GLUED LAMINATED MEMBERS: Glued Laminated members shall each bear an AITC identification mark and be accompanied by an AITC certificate of conformance. One coat of end sealer shall be applied immediately after trimming either shop or field. Members shall be Visual Graded Western Species Inductrual, Architectural or Premium grade with strength as follows: Plan Symbol Common Name Species Fb E GLULAM Glulam DF 24F-V4 DF/DF 2400/1850 psi 1,800,000 psi GLULAM V8 Glulam DF 24F-V8 DF/DF 2400/2400 psi 1,800,000 psi ENGINEERED COMPOSITE LUMBER: Engineered Composite Lumber shall be manufactured by Trus-Joist, Boise Cascade or approved equal and shall have the following minimum strength (based on 12" member depth): Symbol Common Name Manufacturer Fb E PSL Parallam Trussjoist 2900 psi 2,000,000 psi LVL Micolam Trussjoist 2600 psi 2,000,000 psi LSL Timberstrand Trussjoist 1700 psi 1,300,000 psi VL (1%4-2%$") Versa Lam Boise Cascade 2800 psi 2,000,000 psi VL (3%" & wider) Versa Lam Boise Cascade 3100 psi 2,000,000 psi PREMANUFACTURED OPEN WEB WOOD TRUSSES: Trusses shall be design by a Structural Engineer licensed in the State of Washington, who is regularly engaged in the design of plate -connected wood trusses. Truss design shall be accordance with IBC Section 2303.4. Trusses shall be design for the following superimposed dead loads: top chord bottom chord total roof trusses 10 psf 5 psf 15 psf In addition to dead loads, the design shall include the live, wind, snow loads as identified in the "Design Loads" section of these drawings, and the snow drift, sliding and unbalanced loads per ASCE7 Chapter 7. The truss design shall include concentrated and axial loads shown on framing plans and hanger schedules in these drawings. Roof trusses shall be designed for wind net uplift of 10 psf unless otherwise noted on the drawings. Trusses shall be fabricated by a manufacturer who is a member of the Truss Plate Institute. Trusses shall be supplied with the proper hangers, end connections, bridging, bracing to provide lateral stability of all truss members, and tie -down connections to beams and tops of walls. Trusses shall be supplied with tapered hardwood shimming so that every chord bears on the full width of every support, without notching the truss members. The truss manufacturer is responsible for ensuring the bearing seat does not exceed the sill plate capacity of the supporting element. RECOMMENDED INSPECTIONS The following recommended minimum items shall be inspected by a qualified individual provided by the Building Official: -Footings bear on competent native soil per the "Foundations" section above -Footing reinforcement -Shear wall sill plate anchors and washers per schedule -Shear wall nailing and shear clips per schedule -Shear wall hold-downs TYPICAL DETAILS In addition to the details and schedules on the framing plans, those noted as "Typical" shall be used throughout the structure as applicable. STRUCTURAL NOTES SHEAR WALL PER PLAN PT SILL PLATE w/ ANCHOR BOLTS AND WASHERS PER SHEAR WALL SCHEDULE. MINIMUM ANCHOR BOLT EMBEDMENT = 7". 24" 44 x 24" MATCH HORIZ 1EINF. 24" #4 x 24" MATCH HORIZ REINF. #4 HORIZ. AT 18" o.c. AND (2) AT LI I (3) #4 VERT. Z TOP OF WALL DOWELS - - 6" THICK WALL ��\ UNLESS NOTED #4 VERT. DOWELS AT 24" o.c. At HOOK OTHERWISE ALTERNATE HOOK AT BASE N \x�� FOOTING PER SINGLE REINFORCING #4x24 O PLAN MATCH HORIZ LL REINF. z a 00 PERF.FTG. DRAIN _ cc m U FOOTING PER PLAN TYPICAL CONCRETE FOUNDATION I j n DIAPHRAGM NAILING SCHEDULE NAIL SPACING NAIL SPACING AT AT BOUNDARIES INTERMEDIATE NAIL SPACING BLKG SIZE OF AND "OTHER" FRAMING AT BLOCKED LOCATION SHEATHING REQD NAIL PANEL EDGES MEMBERS PANEL JOINTS ROOF SEE STRUCT NOTES NO 10d 6" OC 12" OC 6" OC SUB-FLR NO 10d & GLUE 6" OC 12" OC 6" OC DIAPHRAGM NOTES 1. ALL DIAPHRAGM SHEATHING IS TO BE STAGGERED IN THE DIRECTION OF THE PLYWOOD SPAN PER DIAPHRAGM DETAIL 2. PROVIDE BOUNDARY NAILING CONTINUOUS AROUND THE ENTIRE PERIMETER OF THE DIAPHRAGM 3. NAILS SHALL BE COMMON OR GALVANIZED BOX 4. ALL FRAMING MEMBERS SHALL BE 2x MINIMUM NOMINAL WIDTH BLOCKED DIAPHRAGM TYPICAL CONTINUOUS WHERE INDICATED i, i, rPANELJOINT BOUNDARY NAILING BLOCKED CONTINUOUS PANELJOINT INTERMEDIATE NAILING 11 12��=XL MAN =401.w. 4 a _a DIAPHRAGM DETAIL TOP PLATE "OTHER" PANEL EDGE NAILING JOIST/TRUSS TYPICAL DIAPHRAGM NAILING 1 7 SON CS16 WITH (20) 0 DBL. TOP PLATE D AT EACH SIDE. A AS NEEDED. F PER PLAN NOTES: 1. USE THIS DETAIL AT ALL LOCATIONS WHERE BEAM WIDTH EXCEEDS 3%Z" AND/OR BEAM BOTTOM BEARING IS BELOW DOUBLE TOP PLATES. 2. EXTEND BEAMS FOR 5-1/2" BEARING ON 2x6 WALLS, 3-1/2" BEARING ON 2x4 WALLS. TYPICAL PLATE STRAP AT BEAMS I 10 NOTES: 1. VERTICAL REINFORCING NOT SHOWN FOR CLARITY 2. SEE STRUCTURAL NOTES FOR CLEAR COVER DOUBLE REINFORCING TYPICAL CONCRETE WALL AND FOOTING CORNER 2 TOP PL 5 101 01T.,n 1 01 11 nIAII C CAI U CI nC NOTES: SEE STRUCTURAL NOTES FOR TYPICAL TOP PLATE NAILING NOT SHOWN TYPICAL TOP PLATE SPLICE 1 $ II II I I ROOF TRUSSES/ -- I I� RAFTERS BELOW L I I t t I I 2x6 BLOCK BETWEEN ROOF TRUSSES BELOW W/ (2) 16d EA END I I � I I I I i 2x6 PLATE W/ (2) 16d INTO EA ROOF TRUSS i BELOW I� i I I I I 2x4 RAFTERS @ 24"o.c. i POST DOWN TO ROOF / TRUSS BELOW AT 24" o.c. i II a II II m U I V I I _ _ � _ _ _ II I I _ I I I I' I I I I I I I I � I � I � I I � I I TYPICAL ROOF OVERFRAMING 1 1 TYPICAL EXTERIOR ISOLATED FOOTING 1 $ CRIPPLE STUDS AT 16 O.C. WHERE APPLICABLE TOP PLATES NAIL STUD TO HEADER W/ (8) 16d STUD(S) PER PLAN FULL HEIGHT TO TOP PLATES TRIM STUDS (TRIMMERS) PER POST PLAN SOLID BLKG MATCH WIDTH OF BEAM/GIRDER TYPICAL HEADER DETAIL 1 9 RESUB Nov 29 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 12 Ross Engineering Design Inc ryan.ross@rossengineer.com 11.18.2021 y PN N. ?o OF WAS,y7i,, s ti 2 J B# 21 34 46411 �fGISTE-1�j sS�4N AL ELECTRONIC COPY ORIGINAL ON FILE AT ROSS ENGINEERING DESIGN H Z W Z V CD Z CD CD 00 W W a ID � N 0 LW 0 z Z LU W O O LU W W Im P_ LU 2 W LL Lu Cn Z U U J )U w Z o O oM �a o Q%0 m R 0 c 0 r .Q- c`� a� G C Z FILE/ NO. 21034 DESIGNED BY RR DRAWN BY RR CHECKED BY RR SHEET: S1 PRINT DATE 8 / 2 / 2021 «3 IE r----------------- IF - I SW2 r I Nay°� v � MAIN FLOOR SHEARWALLS SCALE: 1 /8" = 1'-0" EXTERIOR WALLS NOT MARKED SHALL BE SW1 HOLDDOWNS CALLED OUT ARE LOCATED AT BASE OF SHEAR WALLS. SEE SHEET S5 FOR SHEAR WALL SCHEDULE AND TYPICAL SECTIONS J A B C 37'-6" 31'-0" ° �F-01 j • TYP. 6" CONCRETE STEM WALL Q • ON 16"x8" CONCRETE FOOTING ----------- � C-- --------------------- CONCRETE SLAB FLOOR 4" CONC. SLAB. OVER 2" RIGID INSULATION - -- - - - - - - - - - 6 I I 6-6" 5'-6Y4" --------------- j z � I S1 i - J- - - — - — - — - — - — - — - — - — - — - — - — - — - — - — ——-—---—-—-—-— - — - -�, NO BOLTS - - - - - - - - - - - C D-------------- 12'-6" I I� 6' CONCRETE STEM WbLLI 0q 16"x8" ONCRETE FOOTING NO OLTS -- ------ -----\--------- ---II - N - - - - - - - - - - - - - - - - - - - - - - -- - - - - - - - - - - L- F-0 F-02 18'-6" I I 31'-0" 7'-3" 5' 0"—2'-6Y2" oe 0 F-02 I FOUNDATION PLAN SCALE: 1/4" = 1'-0" FOUNDATION NOTES • VERIFY ALL DIMENSIONS AND FIELD CONDITIONS PRIOR TO COMMENCING ANY WORK. • GENERAL CONTRACTOR AND/OR FOUNDATION CONTRACTOR SHALL VERIFY THE LOCATION OF ANCHOR BOLTS AND HOLDOWNS PRIOR TO POURING CONCRETE. • ALL FOOTING SHALL BEAR 18" BELOW UNDISTURBED NATURAL SOIL. FINISHED GRADE SHALL BE NO LESS THAN 12" ABOVE BOTTOM OF FOOTINGS. • TOP OF FOOTING SHALL BE LEVEL. BOTTOM SURFACE OF FOOTING SHALL NOT SLOPE MORE THAN 10%. STEP FOOTING AS NECESSARY TO MAINTAIN MIN. DEPTH OF FOOTING BELOW FINISHED GRADE. • FOUNDATION WALL SHALL EXTEND MINIMUM 6" ABOVE FINISHED GRADE. • ALL WOOD IN CONTACT WITH CONCRETE SHALL BE PRESSURE TREATED. • UNLESS NOTED OTHERWISE OR IN SHEAR WALL SCHEDULE, ALL ANCHOR BOLTS SHALL BE %" dia. x 10" AND EXTEND MINIMUM 7" INTO CONCRETE WITH MINIMUM SPACING OF 48" ON CENTER. EACH ANCHOR BOLT SHALL HAVE A 3"x3"x.229" GALVANIZED WASHER. • SEE SHEARWALL & HOLDOWN SCHEDULES FOR SIZE AND PLACEMENT. • PROVIDE 2" SAND OVER 6 MIL BLACK VAPOR BARRIER OVER 4" COMPACTED GRANULAR FILL UNDER ALL CONCRETE SLABS. • PROVIDE TEMPORARY BRACING AS REQUIRED UNTIL ALL PERMANENT CONNECTIONS ARE IN PLACE. • ALL ISOLATED SPREAD FOOTING TO BE 24"x24"x8" REINFORCE FOOTINGS WITH (2) #4 BARS EACH WAY UNLESS NOTED OTHERWISE IN PLAN. • FOUNDATION WALLS THAT RETAIN EARTH AND ENCLOSE INTERIOR SPACES AND FLOORS BELOW GRADE SHALL BE DAMPPROOFED FROM TOP OF FOOTING TO FINISHED GRADE. (R406.1) • SEE SIMPSON RECOMMENDATIONS FOR HOLD DOWN PLACEMENT. COORDINATE LOCATIONS WITH DOOR & WINDOW ROUGH FRAMING TO PROVIDE ACCURATE DIMENSION FOR OPENINGS. NOTE ! ALL FOUNDATION WALLS TO BE 6" UNLESS CALLED OUT OTHERWISE. LEGEND STEM WALL — FOOTING WALL / FIXTURES OVER CONCRETE SLAB EXISTING CONCRETE FOOTING SCHEDULE SYM. FOOTING SIZE RE -BAR PLACEMENT F-01 *16"x8" CON'T. (2) #4 CON'T. F-02 *24"x24"x8" (2) #4 EA. WY. NOTE: *EXTERIOR FOOTINGS SHALL BE MIN. 18" BELOW GRADE AND REST ON BEARING SOIL. RESUB Nov 29 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 11.18.2021 y PN N. I? Q� OF WgSyiN S' J B# 21 34 46411 /STVE 1j All - ELECTRONIC COPY ORIGINAL ON FILE AT ROSS ENGINEERING DESIGN 1— Z W z V o z N CD Go LJJ W O% � N 0 W o z z W 0 Lu W W V ♦ F W LL w W zV � z n � w w w Lu Q � Z 0 �a o� Q� M w 0 c 0 �L O Z PROJECT NO. DESIGNED BY 210404 TL DRAWN BY TL & RM CHECKED BY TL SHEET: S2 PRINT DATE 11/15/2021 515 PM POST, CAP & BASE SCHEDULE SYM. POST CAP BASE NOTES: P-01 (1) 2x_ STUD w/ (1) TRIMMER (4) 16d NAIL (DBL. TOP PLATE) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. (8) 16d NAILS STUD TO HEADER P-02 2x— STUD w/ (2) TRIMMERS (4) 16d NAIL (DBL. TOP PLATE) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. (8) 16d NAILS STUD TO HEADER P-03 (2) 2x_ STUDS (4) 16d NAIL (DBL. TOP PLATE) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. P-04 (2) 2x— TRIMMERS (4) 16d NAIL (HEADER) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. P-05 PT 44 HF#2 CC44 OR ECC44 ABU44Z w/ %"x5' TITEN HD P-06 46 DF#2 A35 + (4) 16d (DBL. TOP PLATE) A35 + (4) 16d (TOE PLATE) NOTE: SOLID BLOCKING BETWEEN FLOOR @ POINT LOAD BLOCKING TO BE EQUAL TO OR GREATER THEN THE POST ABOVE ------ i i P.L. I I I I I I I I I I I I I I I , I I I , I I I I I I I I I I I I I CONCRETE SLAB FLOOR I I ------------------- I I I I I I I I I I I P.L. I I I , 4, U) 0 _ qq x ~ a A � a BEAM SCHEDULE SYM. BEAM BM-01 4x8 DF#2 OR BETTER BM-02 410 DF#2 OR BETTER BM-03 46 DF#2 OR BETTER BM-04 3.5"x10.5" GLULAM BM-05 PT 4x10 HF#2 NOTE ! POINT LOAD ABOVE. SOLID BLOCKING REQUIRED IN FLOOR FRAMING LEGEND CONCRETE WALL FLOOR PERIMETER FLOOR JOISTS HEADERS & BEAMS STAIR STRINGERS CONCRETE SLAB EXISTING DECK FRAMING N SCALE: 1/4" = V-0" HANGER SCHEDULE -CY^d j -- ---wAmr-pa ------ RESUB Nov 29 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 11.18.2021 y PN N. 1?0 Q� OF WAS' � z J B# 21 34 46411 /STE" sS�4N AL ELECTRONIC COPY ORIGINAL ON FILE AT ROSS ENGINEERING DESIGN H Z W z V o z N CD 00 W W Q a � N 0 W o Z z Lu W O Lu W W V ♦ F W I.L Lu W zV � Z � �a Lu � w w w � Z 0 �a o� Q� M w 0 C O r �L 1..1 O Z PROJECT NO. DESIGNED BY 210404 TL DRAWN BY TL & RM CHECKED BY TL SHEET: S3 PRINT DATE 11/15/2021 515 PM ROOF PLAN NOTES • SEE DESIGN LOADS AND/OR STRUCTURAL NOTES FOR GROUND AND ROOF SNOW LOADS. • FOR MANUFACTUREDED TRUSS ROOFS: ROOF PLAN IS FOR SCHEMATIC PURPOSES ONLY. ACTUAL ROOF PLAN TO BE DESIGNED AND ENGINEERED BY A LICENSED TRUSS ENGINEER. RAFTER FRAMING PER PLAN. • TRUSS LAYOUT TO BE REVIEWED AND APPROVED BY THE TRUSS MANUFACTURER PRIOR TO CONSTRUCTION. • LOCATE DOWNSPOUTS PER SITE CONDITIONS AND PER GENERAL CONTRACTOR. • INSTALLATION OF ALL ROOFING AND WALL FLASHING SHALL BE TO INDUSTRY STANDARDS AND IN COMPLIANCE 5 ---- WITH CURRENT CODES. • PROVIDE CONTINUOUS ALUMINUM GUTTERS ON FASCIA AS SPECIFIED IN DETAILS. • SKYLIGHT SIZES, IF ANY, ARE APPROXIMATE. CONTRACTOR TO VERIFY ACTUAL ROUGH OPENING SIZE PER MANUFACTURER SPECIFICATIONS. • PROVIDE SOLID BLOCKING OVER ALL SUPPORTS. • PROVIDE MIN. 22"x30" ATTIC ACCESS WITH APPROVED WEATHERSTRIPPING. IF ACCESS IS IN A GARAGE, A SELF CLOSING MECHANISM MUST BE INCORPORATED. d • 16d @ 8"o.c. END TRUSS TO TOP PLATES. (TYPICAL AT ALL T GABLE ENDS) • ATTICS WHERE THE MAX. CLEAR HEIGHT BETWEEN JOIST AND RAFTERS IS MORE THAN 42", OR WHERE THERE ARE TWO OR MORE ADJACENT TRUSSES WITH THE SAME WEB CONFIGURATION CAPABLE OF CONTAINING A RECTANGLE 42" HIGH BY 24" WIDE OR GREATER, MUST BE CONSIDERED ATTIC WITH LIMITED STORAGE. • ATTIC SPACE SERVED BY A FIXED STAIR SHALL BE DESIGNED TO SUPPORT THE MIN. LIVE LOAD FOR SLEEPING ROOMS. ATTIC VENTILATION CALCULATIONS ATTIC VENTILATION (R806.1 & 806.2) PROVIDE 1 SQ. FT. OF ATTIC VENTILATION FOR EACH 150 SQ. FT. OF ATTIC AREA. EXCEPTION: PROVIDE 1 SQ. FT. OF ATTIC VENTILATION FOR EACH 300 SQ. FT. OF ATTIC SPACE WHEN NOT LESS THAN 40% AND NOT MORE THAN 50% OF THE REQUIRED VENTILATION AREA IS PROVIDED BY VENTILATORS LOCATED WITHIN THE UPPER PORTION OF THE ATTIC OR RAFTER SPACE. UPPER VENTILATORS SHALL BE LOCATED NOT MORE THAN 3 FEET BELOW THE RIDGE OR HIGHEST POINT OF THE SPACED MEASURED VERTICALLY WITH THE BALANCE OF THE REQUIRED VENTILATION PROVIDED BY EAVE OR CORNICE VENTS. WHERE THE LOCATION OF WALL OR ROOF FRAMING MEMBERS CONFLICTS WITH THE INSTALLATION OF UPPER VENTILATORS, INSTALLATION OF MORE THAN 3 FEET BELOW THE RIDGE OR HIGHEST POINT OF THE SPACE SHALL BE PERMITTED. UPPER ROOF VENT CALCULATIONS ROOF AREA 992 SQ FT REQUIRED ROOF VENTILATION AREA/ 300 3.31 SQ FT 40-50% IN UPPER & LOWER ROOF ROOF VENT AREA/ 2 1.65 SQ FT VENT BLOCKS IN EAVES BLOCKS = AREA/ 0.074 23 ROOF VENTS IN UPPER 40-50 % OPTION 1: AF50 ROOF JACK= AREA/ 0.333 5 OPTION 2: (ridge vent) CORAVENT V300 = AREA/ 0.094 17.6 FEET POST, CAP & BASE SCHEDULE SYM. POST CAP BASE NOTES: P-01 (1) 2x_ STUD w/ (1) TRIMMER (4) 16d NAIL (DBL. TOP PLATE) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. (8) 16d NAILS STUD TO HEADER P-02 2x_ STUD w/ (2) TRIMMERS (4) 16d NAIL (DBL. TOP PLATE) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. (8) 16d NAILS STUD TO HEADER P-03 (2) 2x_ STUDS (4) 16d NAIL (DBL. TOP PLATE) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. P-04 (2) 2x_ TRIMMERS (4) 16d NAIL (HEADER) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. P-05 PT 4x4 HF#2 CC44 OR ECC44 ABU44Z w/ %"x5" TITEN HD P-06 46 DF#2 A35 + (4) 16d (DBL. TOP PLATE) A35 + (4) 16d (TOE PLATE) lNOTE:I SOLID BLOCKING BETWEEN FLOOR @ POINT LOAD BLOCKING TO BE EQUAL TO OR GREATER THEN THE POST ABOVE A B C D I I I I I I I I I I I I I I I I I I I I I I I I SEE DETAIL 2/S5 BM-03 SEE DETAIL 2/S5 MFG. MONO TRUSSES @24" O.C. LOWER ROOF ROOF PLAN SCALE: 1/4" = 1'-0" FOR SCHEMATIC PURPOSES ONLY. REFER TO TRUSS FRAMING PLANS PER MANUFACTURER AND PREPARED BY A LICENSED TRUSS ENGINEER. O� I IBM-01 N � RIDGE � I C"i � NO - I BEAM SCHEDULE SYM. BEAM BM-01 4x8 DF#2 OR BETTER BM-02 410 DF#2 OR BETTER BM-03 46 DF#2 OR BETTER BM-04 3.5x10.5" GLULAM BM-05 PT4x10HF#2 HANGER SCHEDULE _ cvnd I Hntllrplz NOTE ! DOF FRAMING MEMBERS TO BE 1ANUFACTURED TRUSSES @ 24" O.C.(U.N.O.) :ADER NOTE! LEADERS NOT CALLED BUT IN PLAN SHALL BE: O� BM-01 Q LEGEND TRUSSES RAFTERS --- TRUSSES (TOP CHORD) OVER FRAMING = GIRDER TRUSS WALLS UNDER — HEADERS & BEAMS — ROOF LINES EXISTING RESUB Nov 29 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 11.18.2021 y PN N. 1?0 Q� OF WAS' z J B# 21 34 46411 /STERN-� sS�ON ELECTRONIC COPY ORIGINAL ON FILE AT ROSS ENGINEERING DESIGN H Z W z V o z N CD Go LJJ W 0 0% � � N Q Lu z Z Lu W O O Lu W W V ♦ F W LL w W zV � z j In L w w w Lu � 0 Z 0 o� Q� C.)�a c 0 a w m C z PROJECT NO. DESIGNED BY 210404 TL DRAWN BY TL & RM CHECKED BY TL SHEET: PRINT DATE 11/15/2021 515 PM HANDRAIL BY OTHERS GUARDRAIL ATTACHMENT AND RIM BRACING PER MANUFACTURER RIM BEAM/JOIST PER PLAN MINIMUM WIDTH PER MANUFACTURER ROOF BOUNDARY NAILING TRUSS BLOCKING PANELS OVER FULL LENGTH OF SHEAR WALL SHEAR WALL SHEAR CLIPS EDGE NAILING SHEAR WALL PER PLAN J PRE -MANUFACTURED 1 DECK JOISTS PER PLAN (WHERE JOISTS ARE PARALLELTO RIM PROVIDE 2x BLOCK AT EACH RAIL POST OR ALTERNATE PER MANUFACTURER) MONO TRUSSES PER PLAN SECTION 11 �� D EAR WALL N��� TYPICAL SHEAR WALL SCHEDULE STyoX 4x6 POST PER PLAN LCE4 EACH FACE NUMBER OF SHEAR WALL STUD/BLKG. SILL PLATE / SOLE PLATE SW_ (2) SDS25412 SHEATHED EDGE 1 AT ADJOINING FRAMING ANCHOR TO NAIL/SCREW 67 HOLD-DOWN ID EACH END SYMBOL SHEATHING SIDES NAILING PANEL EDGES s SIZE CONCRETE s TO RIM JOIST SHEAR CLIPS 0 SHEAR CLIPS PER SHEAR WALL SHEAR WALL KEY SWl 1 8d @ 6" OC 2x 2x 5/8" DIA. AB 3"x.131" NAIL 3"x.131" TOENAIL SCHEDULE WHERE APPLICABLE TYP. 46 BEAM @ 48" OC @ 6" OC @ 6" OC (4) %" x 8" LAG SW2 1 8d @ 6" OC 2x 2x 5/8" DIA. AB 16d BOX NAIL LTP4 @ 24" OC SQUASH BLOCKS IN RIM JOISTS AT @ 48" OC @ 6" OC SCREWS (2) KBS1Z TOP AND SEE STRUCT 5/8" DIA. AB 16d BOX NAIL ALL POSTS AND HOLD-DOWNS, ALL IIIII III III 11 III III III I: I m SW3 1 8d @ 4" OC 2x 2x LTP4 @ 18" OC LEVELS. SEE TYPICAL POST BLKG. @ 32" OC @ 4" OC 09 BOTTOM _ - - - - - NOTES DETAIL TYP. _ "' - - - - - SW4 1 8d @ 3" TT LTP4 @ 14" OC - -� r 71 OC Z 3x OR DBL. 2x4 2x 5/88" DIAOAB 16d@BOX 4-1/2" ONCAIL I I'I I I I I: BLKG PER SCHED AT HORIZ. = z a 5/8" DIA. AB 16d BOX NAIL ANCHOR TYPE HOLD DOWN W/ J I I I _ I I _ _LI PANEL JOINTS w/ EDGE TYPICAL TOENAIL SW5 1 8d @ 2" OC 3x OR DBL. 2x 2x LTP4 @ 10' OC / ANCHOR ROD PER HOLD-DOWN NAILING BOTH SIDES OF @ 18" OC @ 2.5" OC2 I I I,I F SHEAR WALL SCHEDULE NOTES SCHEDULE TYP. I I I I I'I I I j l I JOINT TYP. 1. NAILS SHALL BE COMMON OR GALVANIZED BOX UNLESS NOTED OTHERWISE. 8d AT 12" o.c. NAILING AT ALL 2. WHERE NAIL SPACING IS LESS THAN 4"0c, STAGGER NAILS %"• I I I 3. ALIGN ALL VERTICAL ADJOINING PANEL EDGES WITH STUD PER SCHEDULE. PROVIDE BLOCKING PER SCHEDULE AT ALL INTERMEDIATE SUPPORTS I I LOCATE VERTICAL PANEL I I I 4x4 BRACE I I I JOINT ON STUD EDGE HORIZONTAL ADJOINING PANEL EDGES. PANEL EDGE NAILING TYP. NAILING BOTH SIDES OF 4. 3x FRAMING MAY BE SUBSTITUTED WITH (2)2x NAILED TOGETHER W/ 16d NAILS MATCHING EDGE NAIL SPACING. JOINT STAGGER PER NOTE #2 SILL/SOLE PLATE W/ _ 5. AT SW1 PROVIDE STANDARD CUT WASHERS AT ALL SILL BOLTS. AT SW2 AND HIGHER PROVIDE 3"xTV4" STEEL PLATE ANCHORS PER SCHED. TYP. MIN (2) STUDS AT EACH 00 WASHERS. LOCATE EDGE OF WASHER WITHIN 1/2" OF EDGE OF SHEATHED SIDE OF SILL PLATE. HOLE IN WASHER MAY BE HOLD-DOWN UNLESS v DIAGONALLY SLOTTED 1.75" MAX. ANCHOR TYPE HOLD-DOWN NOTED OTHERWISE PER 6. ENSURE ONE CLIP EACH END OF SHEAR WALL AT EACH REQUIRED FACE OF SHEATHING. PER PLAN WHERE APPLICABLE. PLAN OR POST 7. SHEAR CLIPS ARE REQUIRED ONLY AS INDICATED IN THE SECTIONS. SEE SCHEDULE FOR ANCHOR tSCHEDULE TYP. 8. SEE DETAIL (TOP FAR RIGHT) FOR TYPICAL TOENAIL ROD TYP. 44 VERT STRAP TYPE HOLD-DOWN SEGMENTAL SHEAR WALL PER PLAN TYP. 2 3/4" MAX NOTCH N d � T RIM BEAM/JOIST PER PLAN 3" MIN SITE -BUILT JOISTS PERP. TO RIM ROOF CONT. SECTION AT KNEE BRACE 1 2 6x6 HANDRAIL POST AT 48" o.c. 2x BLOCK WITH (4) 16d ENDNAIL EACH END AND (2) SDS25600 EACH POST r — — — — J 2 3/4" MAX NOTCH IN POST iv a �T RIM BEAM/JOIST PER PLAN SITE -BUILT 3" MIN JOISTS PARALLEL. TO RIM 6x6 HANDRAIL POST AT 48" o.c. (2) SDS25500 ROOF SHEATHING PER STRUCTURAL NOTES ROOF BOUNDARY NAILING 2x BLOCKING PANELS PROVIDED BY TRUSS MANUFACTURER SHEAR WALL SHEAR CLIPS I EDGE NAILING 2x BLOCK AT EACH SHEAR WALL PER PLAN POST WITH (4) 16d EACH END SECTION AT HAND RAIL 1 7 U MIV1 -IN rumiV TRUSS TO BEAM 112 17 ROOF TRUSSES PER PLAN H1 CLIP EACH TRUSS SHEAR WALL AT RAISED TRUSS HEEL 1 $ ROOF BOUNDARY NAILING CONT. 2x BLKG WITH VENTING PER ARCHITECTURAL. SEE 8/S5 FOR ALTERNATE AT RAISED TRUSS HEELS. EDGE NAILING SHEAR WALL PER PLAN TYP EDG ROOF SHEATHING PER STRUCTURAL NOTES ROOF TRUSSES PER PLAN H1 CLIP EACH TRUSS 2x6 STUDS AT 16" o.c. TYP PRESSURE TREATED SILL PLATE PER SHEARWALL SCHEDULE. BOLT EMBED = 7" MIN. FOUNDATION PER PLAN SHEAR WALL SCHEDULE AND NAILING DETAIL 1 5 ROOFBOI'"'^""" SF c SHI EDG PRESSURE TREATED SILL PLATE PER SHEARWALL SCHEDULE. BOLT EMBED = 7" MIN. FOUNDATION PER PLAN WALL SS FRAMING PERPENDICULAR TO WALL FRAMING PARALLEL TO WALL 13 TYPICAL STRUCTURAL WOOD WALL/SHEAR WALL ASSEMBLIES 15 RESUB Nov 29 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Ross Engineering Design Inc ryan.ross@rossengineer.com 11.18.2021 y PN N. RO OF WASy�N s � o ti J B# 21 34 46411 'PfGISTE?,t� sS�4N AL ELECTRONIC COPY ORIGINAL ON FILE AT ROSS ENGINEERING DESIGN Z W Z V O z N O ao j W W Q 0. W Z uj W O O W W Lu Lu �L :2 W Q uu Z � V U � wV w z V) Uf a ZO Ca o� oM Q%0 ar ca 0 L L Q N d 0 O Z FILE/ NO. 21034 DESIGNED BY RR DRAWN BY RR CHECKED BY RR SHEET: S5 PRINT DATE 8 / 2 / 2021