Energy Calculationssimple neating system size: wasningion state This heating system sizing calculator is based on the Prescriptive Requirements of the 2018 Washington State Energy Code (WSEC) and ACCA Manuals J and S. This tool will calculate heating loads only. ACCA procedures for sizing cooling systems should be used to determine cooling loads. Please complete the green drop -downs and boxes that are applicable to your project. As you make selections in the drop -downs for each section, some values will be calculated for you. If you do not see the selection you need in the drop -down options, please contact the WSU Energy Program at energycode@energy.wsu.edu or (360) 956-2042 for assistance. Project Information Contact Information TOLLEFSON LORI TOLLEFSON & PAUL WATKINS Heating System Type: O All other Systems OO Heat Pump To see detailed instructions for each section, place your cursor on the word "Instructions" Design Temperature Instructions Design Temperature Difference (AT) 46 Edmonds '7 J AT =Indoor (70 degrees) -Outdoor Design Temp Area of Building Conditioned Floor Area Instructions Conditioned Floor Area (sq ft) F 798 Average Ceiling Height Conditioned Volume Instructions Average Ceiling Height (ft) 9.1 7,262 Glazing and Doors U-Factor X Area = UA Instructions u oso � J 0.300 218 65.40 Skylights U-Factor X Area = UA Instructions 0.50 12 6.00 Insulation Attic U-Factor X Area = UA Instructions R 4g I 0.026 J 798 20.75 Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA Instructions --- No Vaulted Ceilings in this project. Above Grade Walls (see Figure 1) U-Factor X Area UA Instructions R-21Intermediate , 0.056 1,115 62.44 Floors U-Factor X Area UA Instructions in No Floors above unconditioned spaces J Below Grade Walls (see Figure 1) U-Factor X Area UA Instructions No Below Grade Walls in this project. � I 0.028 1 00 Slab Below Grade see Figure 11 F-Factor X Length UA InstructionsIN I 0.303 00 No Slab Below Grade in this project. � J Slab on Grade (see Figure 1) F-Factor X Length UA Instructions R-10 Fully Insulated 1 0.360 132 47.52 Location of Ducts Instructions I Duct Leakage Coefficient No Ducts J 1.00 Sum of UA 202.11 Envelope Heat Load 9,297 Btu / Hour Figure 1. Sum of UA x AT Air Leakage Heat Load 3,608 Btu / Hour Volume x 0.6 x AT x 0.018 Above Grade Building Design Heat Load 12,905 Btu / Hour Air leakage + envelope heat loss Building and Duct Heat Load 12,905 Btu / Hour Ducts in unconditioned soace: sum of buildina heat loss x 1.10 Ducts in conditioned space: sum of building heat loss x 1 Maximum Heat Equipment Output 16,131 Btu / Hour Buildino and duct heat loss x 1.40 for forced air furnace Buildino and duct heat loss x 1.25 for heat puma (07101113)