REV I APPROVED BLD2021-1362+Structural_Plan+2.10.2022_2.08.14_PM+2674296GENERAL NOTES All design and construction shall conform to the requirements of the 2018 International Building Code. Contractor shall verify all levels, dimensions and existing conditions in field before proceeding with any construction or demolition. Contractor shall notify the Architect of any discrepancies or field changes Contractor shall be responsible for all safety precautions and the methods, techniques, sequences or procedures required to perform the work. Contractor shall provide adequate shoring and bracing of all structural members, existing construction and soil excavations as required, in a manner suitable to the work sequence. Temporary shoring and bracing shall not be removed until all final connections have been completed in accordance with the drawings and materials have achieved design strength. Foundations walls greater than 4 feet shall not be backfilled until the floor framing and all connections to the floor framing per these details are complete. CHANGES: No changes to these structural drawings are permitted without written consent of the Engineer. Changes will be billed to the client, owner or contractor at the Engineer's hourly rate. SUBMITTALS: Shop drawings shall be submitted to the Architect prior to any fabrication or construction for all the following: Structural steel, steel canopies, glued -laminated members and pre -manufactured wood members. Design drawings and calculations, for pre -manufactured wood trusses and joists shall bear the seal and signature of the Washington State Registered Professional Engineer who is responsible for the design, and shall be submitted to the Architect and Building official for review prior to fabrication. DESIGN LOADS LIVE LOADS: Live loads are determined in accordance with ASCE Ch. 4 L = 40 PSF (Residential) = 60 PSF (Balcony) SNOW LOADS: Snow loads are determined in accordance with ASCE Ch. 7 with the following Factors: Ground Snow Load Pg = 20 psf Ct = 1.0 Ce = 1.0 Roof Snow Load Ps = 25 psf Is = 1.0 WIND LOADS: Wind loads are based on ASCE 7 Ch. 28 (Envelope Procedure) with the following factors: Exposure Category = B Velocity (3 sec) = 100 mph (ult) Kzt = 1.0 Design wind pressured for determining forces on components and cladding are determined in accordance with ASCE 7 Chapter 30. SEISMIC LOADS: Seismic loads are based on the Equivalent Lateral Force Procedure in ASCE 7-10 Section 12.8 with the following factors: Risk Category = II Ss = 1.27 Site Class = D S1 = 0.498 Design Category = D SIDS = 0.846 R = 6.5 (wood shear wall) SD1 = 0.598 Ie = 1.0 Cs = 0.130 (ult.) FOUNDATIONS Concrete foundations shall be placed on Bearing Ground defined as follows. Bearing Ground shall be stiff, competent, non -expansive, undisturbed native soil. Where native soil is inadequate for bearing, foundations shall be placed on structural fill mixed and compacted (and scarified if necessary) in accordance with specifications provided by a Washington State licensed Geotechnical Engineer. Prior to construction, the contractor shall verify the Bearing Ground has minimum allowable bearing pressure = 1500 psf. Bottom of footing elevation shall be located at minimum frost depth 18" below top of finished grade unless required otherwise by the Building Official. The contractor shall confirm the minimum frost depth with the Building Official prior to excavation. CONCRETE Concrete work shall comply, in general, with ACI 301 (latest edition) "Specifications for Structural Concrete for Buildings." CONCRETE MIXES: Concrete mixes shall conform ACI 318 Ch. 5. Minimum concrete strength f'c at 28 days shall be as follows: Slab -on -grade, Curbs and Pads - 2000 psi Footings - 2500 psi Walls, Stems - 3000 psi (2500 psi used for structural design) Water/cement ratio shall be measured by weight and shall be based on the total cementitious material. Water/cement ratio shall be determined by the supplier based on strength requirements and shall not exceed 0.55. Water -reducing admixtures may be incorporated in concrete mix designs but shall conform to ASTM C 464, and be used in accordance with the manufacturer's recommendations. CaCI and other water-soluable chloride admixtures shall not be used. REINFORCING STEEL: All reinforcing shall be deformed bar (rebar) with bar diameters specified in these drawings and properties below: All reinforcing unless noted otherwise - ASTM A615, Grade 60 #3 stirrups and ties - ASTM A615, Grade 40 Welded rebar - ASTM A706, Grade 60 Galvanized Welded Wire Fabric - ASTM A165 Reinforcing steel shall be detailed in accordance with ACI 315 "Manual of Standard Practice for Detailing Reinforced Concrete Structures." Reinforcing steel shall be lapped as noted on the drawings. Where lap length is not shown, reinforcing bars shall be lapped as follows: #5 and smaller - 48 bar diameters #6 and larger - 60 bar diameters Minimum concrete cover over reinforcing shall be as follows: Nonstructural Slab -on -grade - Mid -Depth Wall Bars: interior face - 3/4" exposed to earth/weather - 1-1/2" (#5 and smaller) 2" (#6 and larger) Footings: Bottom Bars - 3" (cast against earth) Top Bars - 1-1/2" Side Bars - 2" Provide supports as required for proper alignment and concrete cover around the reinforcement. Consult the CRSI Manual of Standard Practice MSP-1 for specific information. REVISED PLAN APPROVED CITY OF EDMONDS BUILDING DIVISION BUILDING OFFICIAL Feb 11 2022 APPROVED DATE WOOD SAWN LUMBER: Structural sawn lumber shall be kiln dried and be of the species and grade noted below or better: Use Grade Fb(psi) Wall Studs Hem Fir Stud 675 Plates & Planks Hem Fir #2 850 Joists & Rafters Hem Fir #2 850 4x Beams Douglas Fir -Larch #2 900 6x Beams Douglas Fir -Larch #2 875 Posts Douglas Fir -Larch #2 750 2x4 T&G Decking Douglas Fir -Larch Select 1750 All lumber and plywood exposed to weather or water or in contact with concrete, stucco, masonry or other cementitious materials shall be treated with an E.P.A. acceptable wood preservative, such as Alkaline -Copper -Quaternary "ACQ" or Copper Azole "CBA" type A and B. All wood connectors shall be manufactured by Simpson Strong Tie Company (or approved equal), and of the size and type shown on the drawings. All wood connectors in contact with preservative -treated wood shall be Triple Zinc G-185 galvanized (1.85 oz/sq ft coating). MINIMUM WOOD NAILING REQUIREMENTS: Unless otherwise noted on the drawings, typical wood framing shall be fastened as follows. See IBC Table 2304.10.1 for fastener alternatives not shown. Location Min. Nail Quantity/Spacing Type* Beams (built up 2x's) 3" x 0.131" 24" o.c. T&B* FIN EF* staggered Blocking -to joists, rafters, trusses 3" x 0.131" 2 each end TN or studs -to top plates 3" x 0.131" 3 TN Bottom plate -to joist, rim joist 3" x 0.131" 12" o.c. FIN or blocking -to studs 3" x 0.131" 3 EN Header (built up 2x's) 16d box 12" o.c. T&B FN Header -to studs 3" x 0.131" 4 TN Joist -to supports 3" x 0.131" 3 TN -to rim joist 3" x 0.131" 4 EN Rafter -to supports 3" x 0.131" 4 TN, EN Rim Joist -to sill or blocking 3" x 0.131" 6" o.c. TN Stud -to Stud 3" x 0.131" 12" o.c. FIN -to top/bottom plate 3" x 0.131" 4 TN Top plate -to top plate 3" x 0.131" 12" o.c. FIN -to studs 3" x 0.131" 3 EN -laps at corners and 3" x 0.131" 3 FIN intersections Truss to top plate 3" x 0.131" 4 TN *EN = end nail, FIN = face nail, TN = toe nail, EF = "each face", T&B = "top and bottom" RATED SHEATHING: Wood structural panels shall bear the APA trademark of the American Plywood Association. Sheathing shall be as follows: Shear Wall Shtg APA rated 7/16" 32/16 C-D INT with Exterior Glue (CDX or OSB) Roof Shtg APA rated 15/32" 32/16 C-D INT with Exterior Glue (CDX or OSB) Sub Floor Shtg APA rated 3/4" 48/24 T&G C-D INT with Exterior Glue Sheathing shall be orientated over the supports as shown on the drawings. Shear wall sheathing shall be blocked at all panel edges as shown in the shear wall schedule. GLUED LAMINATED MEMBERS: Glued Laminated members shall each bear an AITC identification mark and be accompanied by an AITC certificate of conformance. One coat of end sealer shall be applied immediately after trimming either shop or field. Members shall be Visual Graded Western Species Inductrual, Architectural or Premium grade with strength as follows: Plan Symbol Common Name Species Fb E GLULAM Glulam DF 24F-V4 DF/DF 2400/1850 psi 1,800,000 psi GLULAM V8 Glulam DF 24F-V8 DF/DF 2400/2400 psi 1,800,000 psi ENGINEERED COMPOSITE LUMBER: Engineered Composite Lumber shall be manufactured by Trus-Joist, Boise Cascade or approved equal and shall have the following minimum strength (based on 12" member depth): Symbol Common Name Manufacturer Fb E PSL Parallam Trussjoist 2900 psi 2,000,000 psi LVL Micolam Trussjoist 2600 psi 2,000,000 psi LSL Timberstrand Trussjoist 1700 psi 1,300,000 psi VL (1%4-2%$") Versa Lam Boise Cascade 2800 psi 2,000,000 psi VL (3%" & wider) Versa Lam Boise Cascade 3100 psi 2,000,000 psi PREMANUFACTURED OPEN WEB WOOD TRUSSES: Trusses shall be design by a Structural Engineer licensed in the State of Washington, who is regularly engaged in the design of plate -connected wood trusses. Truss design shall be accordance with IBC Section 2303.4. Trusses shall be design for the following superimposed dead loads: top chord bottom chord total roof trusses 10 psf 5 psf 15 psf In addition to dead loads, the design shall include the live, wind, snow loads as identified in the "Design Loads" section of these drawings, and the snow drift, sliding and unbalanced loads per ASCE7 Chapter 7. The truss design shall include concentrated and axial loads shown on framing plans and hanger schedules in these drawings. Roof trusses shall be designed for wind net uplift of 10 psf unless otherwise noted on the drawings. Trusses shall be fabricated by a manufacturer who is a member of the Truss Plate Institute. Trusses shall be supplied with the proper hangers, end connections bridging,bracin to provide lateral pp p p 9 � � 9 stability of all truss members, and tie -down connections to beams and tops of walls. Trusses shall be supplied with tapered hardwood shimming so that every chord bears on the full width of every support, without notching the truss members. The truss manufacturer is responsible for ensuring the bearing seat does not exceed the sill plate capacity of the supporting element. RECOMMENDED INSPECTIONS The following recommended minimum items shall be inspected by a qualified individual provided by the Building Official: -Footings bear on competent native soil per the "Foundations" section above -Footing reinforcement -Shear wall sill plate anchors and washers per schedule -Shear wall nailing and shear clips per schedule -Shear wall hold-downs TYPICAL DETAILS n addition to the details and schedules on the framing plans, those noted as "Typical" shall be Ised throughout the structure as applicable. STRUCTURAL NOTES SHEAR WALL PER PLAN PT SILL PLATE AND ANCHOR BOLTS PER SHEAR WALL SCHEDULE 6" THICK CONC. STEM WALL REINF. w/ #4 VERT. AT 24" o.c. AND #4 HORIZ. AT 18" o.c. AND (2) AT TOP. ALTERNATE HOOK. REINFORCED SLAB ON GRADE • PER PLAN 24" #4 x 24" MATCH HORIZ REINF. 24" #4 x 24" MATCH HORIZ REINF. Cr SOLID CONCRETE SLAB EDGE La LI I (3) #4 VERT. N u DOWN TO FOOTING - - - DOWELS 2 FOOTING SIZE AND REINFORCING a oo PER PLAN ALT. HOOK SHEAR STIRRUPS PER PLAN START SINGLE REINFORCING #4 x 24" o ��\ �� FOOTING PER 5" FROM CENTER OF PIPE MATCH HORIZ Of = PLAN ADD #4x24" LONG WAY OVER EACH REINF. z w PIPE PILE 2 NOTES: PIPE PILE PER PLAN 1. VERTICAL REINFORCING NOT • • _ I I SHOWN FOR CLARITY m v I I 12" I 2°F 2. SEE STRUCTURAL NOTES FOR CLEAR COVER (3) #4 x DOUBLE REINFORCING m PERFORATED FTG. EACH PILE DRAIN CON'T. TYPICAL CONCRETE FOUNDATION 1 #4 VERT. AT 24" o.c. REINFORCED SLAB ON GRADE PER PLAN TYPICAL CONCRETE WALL AND FOOTING CORNER 1 2 POST PER PLAN POST BASE PER SCHEDULE 12' DIA CONC. PIER (3) #4 VERT. DOWELS 8"PIIN. SOLID CONCRETE \ iv DOWN TO FOOTING N v U FOOTING SIZE AND REINFORCING FOOTING SIZE AND REINFORCING • A PER PLAN A PER PLAN SHEAR STIRRUPS PER PLAN AND 1/S1 SHEAR STIRRUPS PER PLAN AND 1/S1 ADD #424" LONG WAY OVER EACH ADD #424" LONG WAY OVER EACH PIPE PILE • • PIPE PILE i I I _t - I I PIPE PILE PER PLAN - 1 PIPE PILE PER PLAN - Cnv I I 12" m� I 12" (3) #4 x 2VF 1 (3) #4 x 24 EACH PILE EACH PILE SECTION AT INTERIOR GRADE BEAM 1 4 DIAPHRAGM NAILING SCHEDULE NAIL SPACING NAIL SPACING AT AT BOUNDARIES INTERMEDIATE NAIL SPACING BLKG SIZE OF AND "OTHER" FRAMING AT BLOCKED LOCATION SHEATHING REQD NAIL PANEL EDGES MEMBERS PANEL JOINTS ROOF SEE STRUCT NOTES NO 10d 6" OC 12" OC 6" OC SUB-FLR NO 10d & GLUE 6" OC 12" OC 6" OC DIAPHRAGM NOTES 1. ALL DIAPHRAGM SHEATHING IS TO BE STAGGERED IN THE DIRECTION OF THE PLYWOOD SPAN PER DIAPHRAGM DETAIL 2. PROVIDE BOUNDARY NAILING CONTINUOUS AROUND THE ENTIRE PERIMETER OF THE DIAPHRAGM 3. NAILS SHALL BE COMMON OR GALVANIZED BOX 4. ALL FRAMING MEMBERS SHALL BE 2x MINIMUM NOMINAL WIDTH BLOCKED DIAPHRAGM TYPICAL CONTINUOUS WHERE INDICATED r I PANELJOINT � � it �l: � Y.11 li 11 . I. IJ CI 11 � I: 11 BOUNDARY 'I 11 11 11 9: Id r1 IJ it 11 NAILING :t 11 11 11 li li TOP PLATE Ij ac Ij 11 11 II IJ BLOCKED CONTINUOUS 1: IJ PANELJOINT U 11 II "OTHER" PANEL Ia li : �� FI �� EDGE NAILING �I INTERMEDIATE JOIST/TRUSS NAILING DIAPHRAGM DETAIL TYPICAL DIAPHRAGM NAILING 1 7 SON CS16 WITH (20) 0 DBL. TOP PLATE D AT EACH SIDE. JI AS NEEDED. . r PER PLAN NOTES: 1. USE THIS DETAIL AT ALL LOCATIONS WHERE BEAM WIDTH EXCEEDS 3%" AND/OR BEAM BOTTOM BEARING IS BELOW DOUBLE TOP PLATES. 2. EXTEND BEAMS FOR 5-1/2" BEARING ON 2x6 WALLS, 3-1/2" BEARING ON 2x4 WALLS. TYPICAL PLATE STRAP AT BEAMS 110 TOP PL SECTION rj 10% 7u..l1 1 71 AI A 11 C CA/ U C-C NOTES: SEE STRUCTURAL NOTES FOR TYPICAL TOP PLATE NAILING NOT SHOWN TYPICAL TOP PLATE SPLICE 1 $ II II I I ROOF TRUSSES/ I I RAFTERS BELOW I I 2x6 BLOCK BETWEEN ROOF TRUSSES BELOW W/ I I (2) 16d EA END I I I I � I I I I i 2x6 PLATE W/ (2) 16d I I INTO EA ROOF TRUSS I I i BELOW I�I� I I 1 1 � I I 2x4 RAFTERS @ 24"o.c. POST DOWN TO ROOF TRUSS BELOW AT 24" o.c. I I TYPICAL ROOF OVERFRAMING I 1 1 TYPICAL EXTERIOR ISOLATED FOOTING 1 $ CRIPPLE STUDS AT 16" O.C. WHERE APPLICABLE TOP PLATES NAIL STUD TO HEADER W/ (8) 16d STUDS) PER PLAN FULL HEIGHT TO TOP PLATES TRIM STUDS (TRIMMERS) PER POST PLAN a SOLID BLKG MATCH WIDTH OF BEAM/GIRDER TYPICAL HEADER DETAIL 1 9 REVISION Feb 10 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 12 Ross Engineering Design Inc ryan.ross@rossengineer.com 2.9.2022 yPNN.RoS pF WASh7N S 21 34 46411 'PFGISTER�� SS�ON AL ELECTRONIC COPY ORIGINAL ON FILE AT ROSS ENGINEERING DESIGN H Z W Z U o Z N O ao W W 0 0. 3: t/N LLJ Z Z IU W O O W LU W � W LU �L Q W � Z U wV w Z V) O Z Ca o� M Q%0 ar ca c 0 N d 0 6 Z FILE/ NO. 21034 DESIGNED BY RR DRAWN BY RR CHECKED BY RR SHEET: S1 PRINT DATE 2 / 9 / 2021 «3 r----------------- I SW2 r I N�Ayo� v � MAIN FLOOR SHEARWALLS SCALE: 1 /8" = 1'-0" EXTERIOR WALLS NOT MARKED SHALL BE SW1 HOLDDOWNS CALLED OUT ARE LOCATED AT BASE OF SHEAR WALLS. SEE SHEET S5 FOR SHEAR WALL SCHEDULE AND TYPICAL SECTIONS ---------------------------------------------------------------------------------------------------I Contractor to provide S I reports to City Inspector prior I to pouring of footings ---------------------------------------------------------------------------------------------------- I ' I I I i i I ' I I i I REVISED PLAN APPROVED CITY OF EDMONDS BUILDING DIVISION E r i,& Carfeer BUILDING OFFICIAL Feb 11 2022 APPROVED DATE 3" DIA. PIPE PILE DRIVEN TO REFUSAL PER ESNW FIELD REPORT DATED 1/22/2022, TYPICAL (21) PLACES. CONTRACTOR TO VERIFY PIPE WALL THICKNESS. OO7 M n (5) #3 STIRRUPS @ 5" o.c. (2) SIDES OF PIPE PILES TYP, (3) SIDES AT A 3-WAY FOOTING INTERSECTIONS. B ol 01 I I I I I I 12'-3" 31'-0" 9'-6" 37'-6" 9'-3" Q � � 7 II �l�1� ���I■ri��� i �O� s■I�■ ®1®� 11 6-6" 1w F—01 j • TYP. j o o = 6" CONCRETE STEM WALL io a • ON 16"x8" CONCRETE FOOTING w Qom #4 AT 24" o.c. j 10'-7" 10'4" — - fi1rt IV � \ h CONCRETE SLAB FL OR 6" CONC. SLAB. OVER 2" RIGID INSULATION I 5'-6%4' co ----------\O-A — -- - - - - --- - - - � F—o2 I — 1 LO ——------------------ -- — S1 23/a" I, 2%" 12'-6" 18'-6" I I 31'-0" T-T 5'-0"—2'-6Y2" 0 F-03 1 �0- FOUNDATION PLAN SCALE: 1/4" = 1'-0" FOUNDATION NOTES • VERIFY ALL DIMENSIONS AND FIELD CONDITIONS PRIOR TO COMMENCING ANY WORK. • GENERAL CONTRACTOR AND/OR FOUNDATION CONTRACTOR SHALL VERIFY THE LOCATION OF ANCHOR BOLTS AND HOLDOWNS PRIOR TO POURING CONCRETE. • ALL FOOTING SHALL BEAR 18" BELOW UNDISTURBED NATURAL SOIL. FINISHED GRADE SHALL BE NO LESS THAN 12" ABOVE BOTTOM OF FOOTINGS. • TOP OF FOOTING SHALL BE LEVEL. BOTTOM SURFACE OF FOOTING SHALL NOT SLOPE MORE THAN 10%. STEP FOOTING AS NECESSARY TO MAINTAIN MIN. DEPTH OF FOOTING BELOW FINISHED GRADE. • FOUNDATION WALL SHALL EXTEND MINIMUM 6" ABOVE FINISHED GRADE. • ALL WOOD IN CONTACT WITH CONCRETE SHALL BE PRESSURE TREATED. • UNLESS NOTED OTHERWISE OR IN SHEAR WALL SCHEDULE, ALL ANCHOR BOLTS SHALL BE %" dia. x 10" AND EXTEND MINIMUM 7" INTO CONCRETE WITH MINIMUM SPACING OF 48" ON CENTER. EACH ANCHOR BOLT SHALL HAVE A 3"x3"x.229" GALVANIZED WASHER. • SEE SHEARWALL & HOLDOWN SCHEDULES FOR SIZE AND PLACEMENT. • PROVIDE 2" SAND OVER 6 MIL BLACK VAPOR BARRIER OVER 4" COMPACTED GRANULAR FILL UNDER ALL CONCRETE SLABS. • PROVIDE TEMPORARY BRACING AS REQUIRED UNTIL ALL PERMANENT CONNECTIONS ARE IN PLACE. • ALL ISOLATED SPREAD FOOTING TO BE 24"x24"x8" REINFORCE FOOTINGS WITH (2) #4 BARS EACH WAY UNLESS NOTED OTHERWISE IN PLAN. • FOUNDATION WALLS THAT RETAIN EARTH AND ENCLOSE INTERIOR SPACES AND FLOORS BELOW GRADE SHALL BE DAMPPROOFED FROM TOP OF FOOTING TO FINISHED GRADE. (R406.1) • SEE SIMPSON RECOMMENDATIONS FOR HOLD DOWN PLACEMENT. COORDINATE LOCATIONS WITH DOOR & WINDOW ROUGH FRAMING TO PROVIDE ACCURATE DIMENSION FOR OPENINGS. NOTE ! ALL FOUNDATION WALLS TO BE 6" UNLESS CALLED OUT OTHERWISE. LEGEND STEM WALL — FOOTING WALL / FIXTURES OVER CONCRETE SLAB EXISTING CONCRETE FOOTING SCHEDULE SYM. FOOTING SIZE RE -BAR PLACEMENT F-01 *12" WIDE (2) #5 CON'T. TOP x14" DEEP AND BOTTOM F-02 *14" WIDE (2) #5 CON'T. TOP x14" DEEP AND BOTTOM F-03 *24"x24"x8" (2) #4 EA. WY. *EXTERIOR FOOTINGS SHALL BE MIN. NOTE: 18" BELOW GRADE AND REST ON BEARING SOIL. REVISION Feb 10 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 2.9.2022 yPNN./?o pF WASH/,y J' 21 34 46411 /STER�� SS�4NAL ELECTRONIC COPY ORIGINAL ON FILE AT ROSS ENGINEERING DESIGN 1— Z W z V o z N CD OO W 0% W Q � � N Q W z z W O O IH W W V ♦ F W LL w W z zV � In w LU 0 w w � Z 0 �a o0 QCV) M � w, � � N N O N 00 N Cl) w J a z �o 0 oLLW Q zW O� Z �Z W Ow , PROJECT NO. DESIGNED BY 210404 TL DRAWN BY TL & RM CHECKED BY TL SHEET: PRINT DATE 2/9/2022 10:03 AM