FIR2020-0068+Fire_Sprinkler_Plan+7.14.2020_1.41.50_PMNOTE: SYSTEM RISERS TYPICAL FOR ALL UNITS 6' -11/2 12' -9 Storage T" *� ch 0'-10 N N 11/2 N C o;b tair 1 CC �7 st ig 0 ' 51/2 � 2. 12 -1 1NOTE: ALL PIPES 1" 1-67 UNLESS NOTED OTHERWISE ON PLANS ti 1-71 o ;� Room N10 0'-10" ��° o -7.5 N� o ��O* e r 2' -111/2 1-77 2 -10 g'_21/2 9'-9 N t T co ra r cm +761 ^'ry for Stor 01 1 N • ` 102.3 202.3 �_ "� 1 /2 �roStfal�r 2 LilSt2. rl- FIRST FLOOR ` FPO SCALE: 1/4111 =1 9'0 `♦ ALL INTERLEVEL RISERS SIZES AS NOTED FOLLOW CPVC GUIDELINES FROM MANUFACTURER FOR RISER CLAMPS. DO NOT SQEEZE CPVC PIPES WITH RISER CLAMPS NOTE: OFFSETS MAY BE REQUIRED FROM RISERS TO ACHIEVE DESIRED CENTER LINES Approved by Fire 07/27/2020 A F M ttere' Approved set of plans must be on site at the time of inspection. Failure to provide the approved set may result in a re -inspection fee. System gauge and drain(s) required at riser. Drain must extend to the exterior. If riser is above lowest grade, 2nd drain required and signage at riser indicating location. Flow Through systems require signage IAW NFPA 13D, a system pressure test (125 PSI Min) and proof of NICET installer Certifications. Coverage required to the following areas: Clothes closets, linen closets and pantries exceeding 24 square feet in area, with the smallest dimension greater the 3' and having wall and ceiling surfaces of gypsum board. Bathrooms more than 55 square feet in area. All fuel fired equipment in garages, on covered decks or porches, at least one quick -response intermediate temperature sprinkler shall be installed above the equipment. Attics are exempt if above living space. ------------ r�rr era+,m —�. 425-301 -8707 -- .00 - - - - - - 1 1/2" CPVC INTER -LEVEL CONNECTION EXPRESS RISER TO 4TH FLOOR Disclaimer C? LA i ntry 03 N DS Storage 103.1 ' 6 11/2 N1'-10i��II - A^tti 0.0 UP 000000 000 ' 4'- 31/2000 NOTE: MAXIMUM SPRINKLER SPACINGS SHOWN AT EACH SPRINKLER LOCATION NOTE: ELEVATE ALL PIPES TO 8 -9 A.F.F. HE DRAWINGS FOR THIS PROJECT HAVE BEEN PREPARED BY HOME TEAM FIRE PROTECTION, LLC AS A ESIGN FOR AN NFPA 13R FIRE SUPPRESSION SYSTEM FOR YOUR USE IN THE SPECIFICATION, BIDDING, ND SALE OF SUCH SYSTEMS. THEY HAVE BEEN PREPARED TO PROFESSIONAL STANDARDS OF DESIGN AND DNSTRUCTION BASED UPON INFORMATION PROVIDED BY YOU. BEFORE STARTING ANY WORK ASSOCIATED ►ITH THIS DESIGN, IT IS REQUIRED THAT YOU MAKE A CAREFUL CHECK OF PIPE SIZE, CALCULATIONS, ATERIALS, AND FIRE CODES USED. YOU MUST REPORT ANY ERRORS OR DESIGN CHANGES TO HOME TEAM [RE PROTECTION , LLC TO DETERMINE IF THE DESIGN REQUIRES REVISION. HOME TEAM FIRE PROTECTION, -C DISCLAIMS ANY LIABILITY OR RESPONSIBILITY FOR THE DESIGN ANS SPECIFICALLY DISCLAIMS ANY FARRANTIES WITH REGARD TO THE DESIGN OR ITS USE. ALL DESIGNS PROVIDED ARE "AS IS". IT SHALL B DUR SOLE RESPONSIBILITY TO ENSURE THE SYSTEM WILL FUNCTION IN ACCORDANCE WITH ALL PPLICABLE CODES, ORDINANCES, AND SPECIFICATIONS. NOTE: SPRINKLER LOCATIONS ARE APPROXIMATE. ALL DIMENSIONS TO BE FIELD VERIFIED. RELOCATION OF SPRINKLERS WITHOUT ADDING EXCESSIVE FITTINGS OR PIPING IS ACCEPTABLE PROVIDED THAT THE SPRINKLERS STAY WITHIN THEIR DESIGNATED SPACING REQUIREMENTS SHOWN; e.g. 16X16, 18X8. RELOCATE SPRINKLERS TO AVOID OBSTRUCTIONS AND HEAT SOURCES. IDS IDS Elec wall heater, provide min R10 rigid insulation between back of unit and face of sheathing, typical all locations o 0'-10 7' - F c RO�'� � � 0 AD r 400* 000 . b e. N ' N �N ��..#I �� • `CO Q' ' �� �A 0? t�i_ 0 S r1 Entry 203 76% �„� 7� IDSStorage 203.1 0?-10 O . �� + '}b �Stal 1�-1 1/2 ►� ►\'ti .�-76� . UP 0'-4 *NCO 1. -4bf ge 9' -71/2 ,6% 9' -71/2 1-1/2 Nro KQo�` 76, 7 Office 302 c;, ri 0' -111/2 5, wall heater 301 5'-8 1'-1 L0 >�110 o 2 SECOND FLOOR PO SCALE: 1/411=11-C'1 RECEIVED Jul 17 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT FI R2020-0068 Grid to face of conc Sprinkler Legend Symbol Manufacturer SIN Model Quantity K-Factor Type Size Response Finish Temperature Note Generic VK4680 FIR 72 4.9 Pendent '/2 Quick White 1550F FREEDOM RESIDENTIAL PEND Generic VK486 FREEDOM SW 8 4.2 Sidewall '/2 Quick Chrome 155°F RESIDENTIAL SIDEWALL Generic QRDSW 4 5.6 Sidewall '/2 Quick Chrome 1550F 14" ECQR DRY SIDEWALL Generic VK4680 6 4.9 Pendent '/2 Quick White 175°F FREEDOM RESIDENTIAL PEND Total = 90 4.1 1" INTERLEVEL CONNECTIONS UP TO NEXT LANDING - I ' ' 01 1 1/2" CTS POLY UNDERGROUND I 0 1 1/2" GROOVED BUTTERBALL VALVE 1 1/2" GROOVED CHECK VALVE ® 1 1/2" GROOVED RISER MANIFOLD �5 TEE TO FDC (SEE NOTE) © 1 1/2" CPVC TO SYSTEM PIPE TO FDC (SEE NOTE) 1" MAIN DRAIN ® SINGLE F.D.C. (SEE NOTE FOR SIZE) NOTE: IF ACCEPTABLE RUN 1 1/2" PIPE TO SINGLE 1 1/2" F.D.C. UPSIZE IF REQUIRED TO 2 1/2" SINGLE FDC LINE. USE 1-1/2 X 2-1/2 GROOVED REDUCING COUPLING AT RISER on O 3 RISER DETAIL P01) SCALE: N.T.S. BELL STREET ■ ■ 100' 1 1/2" CTS POLY TO CITY MAIN ■ HORN & STROBE X 2 4 SITE PLAN PO N.T.S. 650 BELL STREET TOWNHOMES 650 BELL STREET EDMONDS, WA 98020 ARROW FIRE PROTECTION LLC 809 E MOUNTAIN VIEW AVE. ELLENSBURG, VITA 98926 CONTACT: I JASON DUBY CONTACT # 1 425.301.8707 LOW DATA 'ROVIDED BY: CITY :ITY MAIN SIZE: 8" STATIC PSI: 55 ZESIDUAL PSI: 45 LOWING: 1000 GPM HORN & STROBE X 2 001008 DAN HUBBARD, SET rERT.LEVEL: V - 115052 8726 SQ. FT. /22/2020 SHEET DESCRIPTION LEVELS 1 AND 2 SHEET NUMBER EO FP01 �O 2 THIRD FLOOR P SCALE: 1/411=1 V—O'V Dress 112 Bedrm 109 -6'r2 oNOO Hall 106 Dress 212 asionivi im kni NEEM ANOW 14 Be� 314El ♦ ` M Imo` 01 Garage 312 7' -1 �13 �* 425-30 1 -8707 Stair 4 406 306 Bedrm 2 9' r2 209 o ^1ry co 0 6 1-4 7�'�' 70 Hall 206 Storage 206. po� 761 1 01 Stair' -3 /2 / 761 0' -5' 1' 04 I Aedrm 1 / 207 / o / 1' -2'/2 7� Bedrm \ 404 J C? / 76t t N 76% M 7'-7 6'-7 Room 402 rL old Hydraulic Information Remote Area 1 OCCUPANCY CLASSIFICATION Residential 13R DENSITY (gpm/ft2) 0.05 for 900ft2 (Actual 380ft2) TOTAL HOSE STREAMS 20.00 DRY CAPACITY 0.00gal TOTAL HEADS FLOWING 4 K-FACTOR 4.2 TOTAL WATER REQUIRED 74.85 TOTAL PRESSURE REQUIRED 48.677 BASE of RISER (gpm) 74.85 BASE of RISER (psi) 48.677 SAFETY MARGIN (psi) +6.321 (11.5%) 1 1 /2" CPVC INTER -LEVEL CONNECTION EXPRESS RISER TO 4TH FLOOR i Diu �n it -224 11/2 16' -6'/2 I I \'n I � I I Disclaimer HE DRAWINGS FOR THIS PROJECT HAVE BEEN PREPARED BY HOME TEAM FIRE PROTECTION, LLC AS A ESIGN FOR AN NFPA 13R FIRE SUPPRESSION SYSTEM FOR YOUR USE IN THE SPECIFICATION, BIDDING, ND SALE OF SUCH SYSTEMS. THEY HAVE BEEN PREPARED TO PROFESSIONAL STANDARDS OF DESIGN AND DNSTRUCTION BASED UPON INFORMATION PROVIDED BY YOU. BEFORE STARTING ANY WORK ASSOCIATED IITH THIS DESIGN, IT IS REQUIRED THAT YOU MAKE A CAREFUL CHECK OF PIPE SIZE, CALCULATIONS, ATERIALS, AND FIRE CODES USED. YOU MUST REPORT ANY ERRORS OR DESIGN CHANGES TO HOME TEAM [RE PROTECTION , LLC TO DETERMINE IF THE DESIGN REQUIRES REVISION. HOME TEAM FIRE PROTECTION, -C DISCLAIMS ANY LIABILITY OR RESPONSIBILITY FOR THE DESIGN ANS SPECIFICALLY DISCLAIMS ANY FARRANTIES WITH REGARD TO THE DESIGN OR ITS USE. ALL DESIGNS PROVIDED ARE "AS IS". IT SHALL B DUR SOLE RESPONSIBILITY TO ENSURE THE SYSTEM WILL FUNCTION IN ACCORDANCE WITH ALL PPLICABLE CODES, ORDINANCES, AND SPECIFICATIONS. -22 -23 1-23 O ♦♦ ♦ ♦ ♦ ♦ NOTE: REMOTE AREA 1 SUPPLY NODES FOR CLARITY 1-5 1-7 1-67 1-77 Hydraulic Information ♦♦ Remote Area 2 OCCUPANCY CLASSIFICATION Residential 13R DENSITY (gpm/ft2) 0.05 for 900ft2 (Actual 337f0 TOTAL HOSE STREAMS 20.00 DRY CAPACITY 0.00gal TOTAL HEADS FLOWING 4 K-FACTOR 4.2 TOTAL WATER REQUIRED 74.38 TOTAL PRESSURE REQUIRED 46.130 BASE of RISER (gpm) 74.38 BASE of RISER (psi) 46.130 SAFETY MARGIN (psi) +8.868 (16.1%) NOTE: MAXIMUM SPRINKLER SPACINGS SHOWN AT EACH SPRINKLER LOCATION Family 117 0' 1- N N ' 1-504 si nti 3TR■.05gpm/ft21 icy 11/2 ° O 90 OF 5' -0 0' -6 - ' -5'/2 N 40 h 1-130°� Dinin + r � 115 - 11 L O 03�4 03 O ' -7 T -5 � N� N 1-51 1-38 1-51CU sti all� �� 3 Storage q 113.1 $p _ ��il o r 5' -2'/21�� 1 O CM ! - /2 to t CV •�r0- �(O 1'-3 Living + 1/2 114 O�O A � M SINGLY DRY SPRINKLER AT 5'-2'/21�� EACH BALCONY �I Bedrm 2 327 Oh ♦ 1' 11' 1-712 NOTE: ALL PIPES 1" UNLESS NOTED OTHERWISE ON PLANS r fib 1-2 NOTE: ELEVATE ALL PIPES TO 8' -9"A. F. F. ALL INTERLEVEL RISERS SIZES AS NOTED FOLLOW CPVC GUIDELINES FROM MANUFACTURER FOR RISER CLAMPS. DO NOT SQEEZE CPVC PIPES WITH RISER CLAMPS 3TE: REMOTE 1-3 SEA 2 SUPPLY NOTE: OFFSETS MAY BE REQUIRED FROM RISERS TO ACHIEVE NODES FOR DESIRED CENTER LINES CLARITY Jul 17 2020 1 THIRD FLOOR CITY E DEVELOPMM DEVELOPMENT SERVICES R ea+�� �` ��i■Fsarr'a■.cY DEPARTMENT a ► Y POSCALE ■ 1 4"—1'—Owl : dw m., 47L- Sprinkler Legend Symbol Manufacturer SIN Model Quantity K-Factor Type Size Response Finish Temperature Note Generic VK4680 FIR 72 4.9 Pendent '/2 Quick White 155°F FREEDOM RESIDENTIAL PEND Generic VK486 FREEDOM SW 8 4.2 Sidewall '/2 Quick Chrome 155°F RESIDENTIAL SIDEWALL Generic QRDSW 4 5.6 Sidewall '/2 Quick Chrome 155°F 14" ECQR DRY SIDEWALL Generic VK4680 6 4.9 Pendent '/2 Quick White 175°F FREEDOM RESIDENTIAL PEND Total = 90 Family q 217 � 3 7� ' 50 +7sr q 11/2 6'-5'r2 0'_ 5'-0 Cfi7s] Kitche r216 ` 215 q \ 3/4 3/4 q 7& 7'- 4W 7� Storageo Q? �p1 213.1 Qb o F ^\ + r 3'-1% N7 76, 213 ' 11/2 ..�.7 5'-2 ry N 61 3'-1CM 2 ���fng �V-3 �. 0,214 M 76� 76�5'-2'/2 SINGLY DRY SPRINKLER AT EACH BALCONY Bedrm 2 407 N 4' -7+r 7 �&0 Stair 3 Stair 4 all 06 ro F .1 4' -3'/2 N11 37 2 iall M 0 0'' 5 �r2 + O p 03/ 4 � 0% 03/4 7320 T_5 * 7'-5 fining 4W Kitchen 10 - 2`` Kitchen 321 *ro+ 411 0+ 1-339 / 1-19 �� 1-340 ` o _ 0% ; 9' -2.1; 0' -6 sidential 1 ■0.05gpi , t2 for 337ft2 to to 1-200 7 % 03/` Livi�.y , -4 , Living 322 7l� o' 1-34 2 0 -2 /q o, 1-34 r C: I SINGLY DRY A. i'i SPRINKLER AT o EACH BALCONY 1-374 `9le.�_ v'g 650 BELL STREET TOWNHOMES ROJECTNO: 001008 SHEET DESCRIPTION 650 BELL STREET DRAWN BY: DAN HUBBARD, SET THIRD AND FOURTH LEVELS ERT. LEVEL: V- 115052 EDMONDS, VITA 98020 Q FEET: 8726 SQ. FT. SHEET NUMBER ARROW FIRE PROTECTION LLC DWG DATE: /22/2020 809 E MOUNTAIN VIEW AVE. ELLENSBURG, WA 98926 CONTACT: I JASON DUBY CONTACT # 1 425.301.8707 GENERAL NOTES: REFER TO NFPA 13R 2013 EDITION 6.4.6.3.4.1 Pendent sprinklers shall be located at least 3 ft (914 mm) from obstructions such as ceiling fans and light fixtures unless the requirements of 6.4.6.3.6 are met. 6.4.6.3.4.2 The distance shall be measured from the center of the sprinkler to the center of the obstruction. 6.6 Location of Sprinklers. 6.6.1 Sprinklers shall be installed in all areas except where omission is permitted by 6.6.2 through 6.6.7. 6.6.2* Sprinklers shall not be required in bathrooms where the bathroom area does not exceed 55 ft2 (5.1 m2). 6.6.3 Except where specified in 6.6.4, sprinklers shall not be required in clothes closets, linen closets, and pantries within dwelling units that meet all of the following conditions: (1) The area of the space does not exceed 24 ft2 (2.2 m2). (2) The least dimension does not exceed 3 ft (0.91 m). (3) The walls and ceilings are surfaced with noncombustible or limited -combustible materials as defined by NFPA 220. 6.6.4* Sprinklers shall be installed in any closet used for heat-ing or air-conditioning equipment, washers, dryers, or waterheaters except as permitted by 6.6.7.6.6.5* Except as provided for in 6.6.5.1, sprinklers shall not bereq u ired in any porches, balconies, corridors, carports, portecocheres, and stairs that are open and attached. 6.6.5.1 Where a roof or deck is provided above, sprin klerssha II be installed to protect attached exterior balconies, at-tached exterior decks, and ground floor patios serving dwell-ing units in buildings of Construction Type V. 6.6.5.1.1 Where sidewa II sprinklers are installed beneathdecks or balconies constructed with open wood joists, sprin-klers shall be permitted to be installed with deflectors not lessthan 1 in. (25 mm) or more than 6 in. (152 mm) below thestructural members, provided that the deflector is not morethan 14 in. (356 mm) below the underside surface of the deck 6.6.7 Sprinklers shall not be required in closets (regardless of size) on exterior balconies and exterior breezeways/corridors, regardless of size, as long as the closet does not have doors or unprotected penetrations directly into the dwelling unit Table 6.4.6.3.6.2 Positioning of Sprinklers to Avoid Obstructions to Discharge (Residential Upright and Pendent Spray Sprinklers) Distance from Sprinklers to Side of Obstruction (A) Maximum Allowable Distance of Deflector Above Bottom of Obstruction (in.) (B) Less than 1 ft 0 I ft to less than I ft 6 in. 0 1 ft 6 in. to less than 2 ft 1 2 ft to less than 2 ft 6 in. 1 2 ft 6 in. to less than 3 ft 1 3 ft to less than 3 ft 6 in. 3 3 ft 6 in. to less than 4 ft 3 4 ft to less than 4 ft 6 in. 5 4 ft 6 in. to less than 5 ft 7 5 ft to Icss than 5 ft 6 In. 7 5 ft 6 in. to less than 6 ft 7 6 ft to less than 6 ft 6 in. 9 6 ft 6 in. to less than 7 ft 11 7 ft and greater 14 For SI units, I in. = 25.4 mm; 1 ft = 0.3048 m. Note: For A and B, refer to Figure 6.4.6.3.6.2. -E 1-3/4 (44.5 rr Maxim) Ceiling - B Obstruction A 101 Elevation View FIGURE 6.4.6.3.6.2 Positioning of Sprinkler to Avoid Ob- struction to Discharge (Residential Upright and Pendent Spray Sprinklers). 1 /8" (28.6 mm) Minimum 211 (50.8 mm) Maximum Ceiling Opening Size: 2-5/16" (58.7 mm) minimum —j tone wan ana gara raring. aet top or — i— railing 42" above toe of stairs with 1.1/2" —dia handrail set 36" above 1. of stairs atatala mount railing system to Conc wall to resist 'T, IBC oveRumfrtg rxiteria and ttpanirlg alas ! —III — 1 —_ I - -III -- I -1 I - — — Ceiling Fr Obstruction D A A>-(D-8in.)+B Wall [A>(D-0.2m)+B] where: D:5 30 in. (0.8 m) ,-ix I Elevation View FIGURE 6.4.6.3.6.3 Positioning of Sprinkler to Avoid Ob- struction Against Wall (Residential Upright and Pendent Spray Sprinklers). 0WOK 1-1/8" (28.6 mm) Minimum Installed with a Micromatic 2-1/2" (63.5 mm) maximum Installed with a threaded Micromatic Model E-1 Recessed Escutcheon Model E-2 Recessed Escutcheon Viking Residential Pendent K4.9 Sprinkler 16876 (VK4680) ♦— 1 r Ir L I II V 1 L u I 1 W 11 L L v 425-30 1 -8707 Disclaimer HE DRAWINGS FOR THIS PROJECT HAVE BEEN PREPARED BY HOME TEAM FIRE PROTECTION, LLC AS A ,ESIGN FOR AN NFPA 13R FIRE SUPPRESSION SYSTEM FOR YOUR USE IN THE SPECIFICATION, BIDDING, ,ND SALE OF SUCH SYSTEMS. THEY HAVE BEEN PREPARED TO PROFESSIONAL STANDARDS OF DESIGN AND ONSTRUCTION BASED UPON INFORMATION PROVIDED BY YOU. BEFORE STARTING ANY WORK ASSOCIATED JITH THIS DESIGN, IT IS REQUIRED THAT YOU MAKE A CAREFUL CHECK OF PIPE SIZE, CALCULATIONS, IATERIALS, AND FIRE CODES USED. YOU MUST REPORT ANY ERRORS OR DESIGN CHANGES TO HOME TEAM IRE PROTECTION , LLC TO DETERMINE IF THE DESIGN REQUIRES REVISION. HOME TEAM FIRE PROTECTION, LC DISCLAIMS ANY LIABILITY OR RESPONSIBILITY FOR THE DESIGN ANS SPECIFICALLY DISCLAIMS ANY JARRANTIES WITH REGARD TO THE DESIGN OR ITS USE. ALL DESIGNS PROVIDED ARE "AS IS". IT SHALL BE OUR SOLE RESPONSIBILITY TO ENSURE THE SYSTEM WILL FUNCTION IN ACCORDANCE WITH ALL PPLICABLE CODES, ORDINANCES, AND SPECIFICATIONS. I!-1 I I-1 I I-1 I I- Conc slab on grade per struct, (in heated arm, with R10 rigid insulation cunt), over 2" sand. 6mll visqueen lop and tape joints 6", set over 4 gravel base R10 ngld insulabon between conic and 2x stud fumng typical Cont footing drainage system per geotech FULL HEIGHT CROSS SECTION SCALE: 1/4" = 1'-0't Fig. A f r\ 1 Irr AIPA nr rW uA11% PAR NOTE: ELEVATE ALL PIPES TO 8-9" +1- A.F.F. I I Conic slap on grade. Isee stluct), non neated area, no rigid insulation below slab set over 2" sand 6md visqueen lap ant ` I Joints 6" & 4" gravel base —_ Typical below grade dampproohng to •lastomenc sealant over concrete v. NOTE: ELEVATE ALL 1 Section looking East 114" = V-0" FIG. 185: DIMENSIONS (IN) • WEIGHT (LBS) CPVC Pipe Size A B oC E F Max. Hanger Spacing (FT.) Approx. WeighU100 (Ibs) 1/4 1°fie 2'h '/4 1'A 1'/4 51h 8 1 1IV, 2% 114 1'A 11h 6 9 11/4 1 "/e 3 '14 1'A 1'A 6'h 10 11h 1'A 3�/t '114 1'A 2'A 7 12 2 1 2 1 3A 1 %4 1 1A 1 21/8 1 8 1 14 1 ALL HANGER TO BE ANVIL STD-0090 ONE HOLE PIPE STRAPS OR ANVIL 188R 2-HOLE OFFSET HANGERS. EQUIVALENTS ARE ACCEPTABLE. FOLLOW MANUFACTURER'S GUIDELINES FOR HANGING. ALL HANGERS ON PROJECT TO FOLLOW HANGING GUIDELINES IF0KS ARE ABSENT FROM DRAWINGS. 2 FP03 CITY OF EDMONDS HANGER [Y R S FP01 N.T.S. minus washed rock, wrap top do not set on underside of pipe) of pipe with non woven geotextrle fabric, overlap adjacent pieces by 6" min ., 4 c .♦ .a♦Y. ♦- ♦� e .d . ♦ 4 ♦" 4 •.♦ a• 4-. ♦ 4 4 F 4 4-0 A. 4 A. Hanger and Restrainer TYPICAL DRY-SIDEWALL REFER TO ANY ADDITIONAL RULES FOR INSTALLATION IN THE MANUFACTURER'S DATA -SPRINKLER DEFLECTOR DISTANCE BELOW CEILING VARIES -MOUNT SPRINKLER DEFLECTOR 1" BELOW EXTERIOR BALCONIES WITH EXPOSED WOOD JOISTS -ALL OTHER SIDEWALL SPRINKLERS TO BE BETWEEN 4" AND 6" OF EXTERIOR CEILINGS AND SOFFITS - DRY SIDEWALL - 1" THREADED C.I. TEE - 1" CPVC X BRASS ADAPTER - CPVC NIPPLE (VARIES) - 1" THREADED C.I. PLUG PROVIDE TENTING IN TO CREATE A CONDITIONED SPACE FOR PIPING TO BE INSTALLED. FOLLOW NFPA 13R GUIDELINES AND MANUFACTURERS DATA. MAINTAIN AN AIR POCKET BETWEEN THE INSULATION AND THE CEILING FOR ALL AREAS WITH PIPE. A 4MIL VAPOR BARRIER IS AN OPTION BUT OTHER MATERIALS SUCH AS PAPER OR BATT INSULATION WILL ALSO WORK. TENT TO 18" MIN ON EITHER SIDE OF PIPES THAT RUN PERPENDICULAT TO TRUSSES. FIG. 188R: DIMENSIONS (IN) • WEIGHT (LBS) CPVC Pipe Size A B eC 0 E F G Max. Hanger Spacing (FT.) Approx. Weight/100 (Ibs) 1/1 21/4 3% 1/4 2 1 25A 1'h 5'h 11 1 21%6 3% '14 2'/16 1 2"/6 1% 6 12 11/4 211frs 31% 'A 21/1a 1 31/4 11h 6'h 13 11h 31A 4% 1/4 2'A6 1 31h 11h 7 14 2 3%, 1 43A '% 2' %s 1 1 1 4 1 11h 1 8 1 16 FIG. 188R: LISTED FASTENERS Pipe Wood and Composite Beams Steel (18ga. Minimum) CPVC Screw Supplied or #10 x 1 " TEK Screw 014 x 1 " TEK Screw or'/4" x 1" TEK Screw Steel & Copper r114 x 1 " TEK Screw or 1/4" x 1'12" lag Screw 014 x 1 " TEK Screw or 1/4" it 1 " TEK Screw Sprinkler Legend Symbol Manufacturer SIN Model Quantity K-Factor Type Size Response Finish Temperature Note Generic VK4680 FR 72 4.9 Pendent 1/2 Quick White 155°F FREEDOM RESIDENTIAL PEND Generic VK486 FREEDOM SW 8 4.2 Sidewall % Quick Chrome 155°F RESIDENTIAL SIDEWALL Generic QRDSW 4 5.6 Sidewall 1/2 Quick Chrome 155OF 14" ECQR DRY SIDEWALL Generic VK4680 6 4.9 Pendent 1/2 Quick White 175°F FREEDOM RESIDENTIAL PEND Total = 90 650 BELL STREET TOWNHOMES 650 BELL STREET EDMONDS, WA 98020 ARROW FIRE PROTECTION LLC 809 E MOUNTAIN VIEW AVE. ELLENSBURG, WA 98926 CONTACT: I JASON DUBY I CONTACT # 1 425.301.8707 TENTING (3RD FLOOR ONLY) SCALE: N.T.S. T01008 DAN HUBBARD, SET r V - 115052 726 SQ. FT. /22/2020 ----------------------------- Are. Pr ig a -.a --- SHEET DESCRIPTION GENERAL NOTES SHEET NUMBER FP03