GEO Addendum LetterCOBALT G E 0 S C I E N C E S July 16, 2020 Wayne Sharp Construction WMesharp.office ftmail.com RE: Geotechnical Addendum Proposed Single -Family Residence 8045 —184th Street SW Parcel No. 27041800103800 Edmonds, Washington Cobalt Geosciences, LLC P.O. Box 82243 Kenmore, Washington 98028 In accordance with your authorization, Cobalt Geosciences, LLC has prepared this letter to discuss additional details regarding our previous infiltration evaluation. We have reviewed a City comment dated February 18, 2020. Our site investigation included a small-scale pilot infiltration test performed in accordance with Appendix B — Methods for Determining Design Infiltration Rates (June 2017 (City of Edmonds)). The testing included an approximately 6-hour pre-soak period followed by testing and verification of soil and groundwater conditions after testing. No groundwater mounding was observed following the testing in an excavation extending approximately 6 feet below grade. We recommend that the bottom of the trenches be situated within native soils consistent with those described in the previous report. We recommend a maximum trench/system depth of 4 feet below grade. Local loosening of the native soils may be required up to 2 feet below the bottom of system elevations. We recommend locating systems at least 40 feet apart and at least 10 feet from property lines. We should be on site to confirm soil conditions and provide additional recommendations if necessary. Sincerely, Cobalt Geosciences, LLC P "ONY,y� -WA�H�c��� If .1�5 - r 54896 ,1vL ,0 7/16/2020 Phil Haberman, PE, LG, LEG Principal www.cobaltgeo.com (2o6) 331-1097