Loading...
RESIDENCE WSECPrescriptive Energy Code Compliance for All Climate Zones in Washington Project Information Contact Information Hoy Marie Anderson @ Nash & Asso Architects Residence (425) 242-7491 913/19, Marie@Nash-Architects.com This project will use the requirements of the Prescriptive Path below and incorporate the the minimum values listed. In addition, based on the size of the structure, the appropriate number of additional credits are checked as chosen by the permit applicant. Authorized Representative All Climate Zones R-Value U-Factor Fenestration U-Factor n/a 0.30 Skylight U-Factor n/a 0.50 Glazed Fenestration SHGC ,e n/a n/a Ceilingk 491 0.026 Wood Frame Wallg.m,n 21 int 0.056 Mass Wall R-Value" 21/21" 0.056 Floor 309 0.029 Below Grade Wall°•' 10/15/21 int + TB 0.042 Slab R-Value & Depth 10, 2 ft n/a "Table R402.1.1 and Table R402.1.3 Footnotes included on Page 2. Date Each dwelling unit in a residential building shall comply with sufficient options from Table R406.2 so as to achieve the following minimum number of credits: 1, Small Dwelling Unit: 1.5 credits ❑ Dwelling units less than 1500 square feet in conditioned floor area with less than 300 square feet of fenestration area. Additions to existing building that are greater than 500 square feet of heated floor area but less than 1500 square feet. ❑� 2. Medium Dwelling Unit: 3.5 credits All dwelling units that are not included in #1 or #3. Exception: Dwelling units serving R-2 occupancies shall require 2.5 credits. ❑3. Large Dwelling Unit: 4.5 credits Dwelling units exceeding 5000 square feet of conditioned floor area. 4. Additions less than 500 square feet: .5 credits Table R406.2 Summary Option Description Credit(s) 1 a Efficient Building Envelope 1 a 0.5 1 b Efficient Building Envelope 1 b 1.0 1 c Efficient Building Envelope 1 c 2.0 1 d Efficient Building Envelope 1 d 0.5 2a Air Leakage Control and Efficient Ventilation 2a 0.5 2b Air Leakage Control and Efficient Ventilation 2b 1.0 2c Air Leakage Control and Efficient Ventilation 2c 1.5 3a High Efficiency HVAC 3a 1.0 3b High Efficiency HVAC 3b 1.0 3c High Efficiency HVAC 3c 1.5 3d High Efficiency HVAC 3d 1.0 4 High Efficiency HVAC Distribution System 1.0 5a Efficient Water Heating 5a 0.5 5b Efficient Water Heating 5b 1.0 5c Efficient Water Heating 5c 1.5 5d Efficient Water Heating 5d 0.5 6 IRenewable Electric Energy 0.5 Total Credits *Please refer to Table R406.2 for complete option descriptions M 0.5 El ❑. El El [] 1.0 ❑ ❑ F11 0.5 El 1.5 El "1200 kWh 0.0 3.50 Window, Skylight and Door Schedule Projoa Information Contact Information oy Marie Anderson Slash & Asso Architects [Residence �(425) 242-7491 [9/3119 __ mana�i Nash-Arch�tecis com Ref. U-factor Exempt Swinging Door (24 sq, ft. max.) JOA9 Exempt Glazed Fenestration (15 sq. ft. max.) 1 10,28 Vertical Fenestration (Windows and doors) Component Description Ref, U-factor Door 0.49 Door 0-49 Fixed 028 i Slider 028 Slider 0.28 Patio Sliding Door 028 Fixed 028 Patio Swing Door 028 Slider 0.28 Fixed 028 Fixed 0.28 Fixed 0-28 Fixed 028 Fixed 0,28 Slider 028 Fixed 0.28 Slider 028 Fixed 0.28 Fixed 0.28 Fixed 0.28 Slider 0.28 Slider 028 Fixed 028 Fixed 0.28 Fixed 0,28 Width Height Qt, Feet Inc" Feet Inc, Area UA i� 3 _ 5 E 15.0 14.20 Width Height Sum of Vertical Fenestration Area and UA Vertical Fenestration Area Weighted U = UA/Area 1141.4 327,51 0.29 Overhead Glazing (Skylights) Component Width Height Description Ret. U-factor Qt. Feet I"`" Feet ln'h Atea UA _ 0.0 0.00 ..-_. ...._........�_.....� 0.0 0,00 0,0 0.00 i 0.0 0,00 0.0 0.00 0.0 0,00 Sum of Overhead Glazing Area and UA 0,0 0.00 Overhead Glazing Area Weighted U = UA/Area 0.00 Total Sum of Fenestration Area and UA (for heating system sizing calculations) 1180.4 343,47 Simple Heating System Size: Washington State This healing system sizing calculator is based on the Prescriptive Requirements of the 2015 Washington State Energy Code fWSEC) and ACCA Manuals J and S. This calculator will calculate heating loads only. ACCA procedures for sizing cooling systems should be used to determine cooling loads. The glazing (window) and door portion of this calculator assumes the installed glazing and door products have an area weighted average U-factor of 0,30. The incorporated insulation requirements are the minimum prescriptive amounts specified by the 2015 WSEC, Please fill out all of the green drop -downs and boxes that are applicable to your project. As you make selections in the drop -downs for each section, some values will be calculated for you. If you do not see the selection you need in the drop -down options, please call the WSU Energy Extension Program at (360) 956-2042 for assistance. Project Information Contact Information Hoy Imarie Anderson @ Nash & Asso Architects Residence 1425) 242-7491 9/3/19, Marie@Nash-Architects.com Heating System Type: All Other Systems 0 Heat Pump To see detailed instructions for each section, place your cursor on the word 'Instructions". Design Temperature Instructions Design Temperature Difference (AT) 46 Edmonds dT = Indoor (70 degrees) - Outdoor Design Temp Area of Building Conditioned Floor Area Instructions Conditioned Floor Area (sq ft) 3.173 Average Ceiling Height Conditioned Volume Instructions Average Ceiling Height (ft) 9.0 28,557 Glazing and Doors U-Factor X Area = UA Instructions 0.30 1,180 354.12 Skylights U-Factor X - UA lnstructir,ns 0.50 (�Area`��j L�J Insulation Attic U-Factor X Area - UA Instructions R-49 0,026 2,935 76.31 Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA ns a ti�is SelexY R•valm . No selection Above Grade Walls (see Figure 1) U-Factor X Area UA Instructions Fi lIntermediate . y 0.056 2.920 163.50 Floors U-Factor X Area UA Instructions R 3a . 0.025 27935 73.38 Below Grade Walls (see Figurer) U-Factor X Area UA (nett actions Select R-value No selection Slab Below Grade (See Figure 1) F-Factor X Length UA Instructions Select conditioning M�ifl -- . - _ - --� No selection --- Slab on Grade (see Floure1) F-Factor X Length UA Instructions • SeIeRR-Value ,. No selection - Location of Ducts hintructio:'s Duct Leakage Coefficient Unconditioned Space . ;, iy ..I 1.10 Sum of UA 667.30 _ Envelope Heat Load 30,696 Btu / Hour Figure 1. Sum or UAXAT Air Leakage Heat Load 14,187 Btu / Hour VolumeX 06XATX.018 tbovr Graur Building Design Heat Load 44,883 Btu I Hour Air Leakage + Envelope Heat Loss M#nw G>+Ms - Building and Duct Heat Load 49,371 Btu / Hour Ducts in unconditioned space: Sum or Building Heat Loss X 1 10 Ducts in conditioned space: Sum or Building Heat Loss X 1 Maximum Heat Equipment Output 69,120 Btu/Hour Building and Duct Heat Loss X 1,40 for Forced Air Furnace Building and Duct Heat Loss X 125 for Heat Pump (07101113)