REVIEWED BLD-resub1 BLD2021-1146+WSEC+(LOCKED)10.14.2021_1.23.07_PM+2463474REVIEWED RESU B BLD2021-1146 BY CITY OF EDMONDS Oct 14 2021 BUILDING DEPARTMENT CITY OF EDMONDS Simple Heating System Size. Washington State """""""""""'-"""""""""""" DEVELOPMENT SERVICES TMENT This heating system sizing calculator is based on the Prescriptive Requirements of the 2018 Washington State Energy Code (WSEC) and ACCA Manuals J and S. This tool will calculate heating loads only. ACCA procedures for sizing cooling systems should be used to determine cooling loads. Please complete the green drop -downs and boxes that are applicable to your project. As you make selections in the drop -downs for each section, some values will be calculated for you. If you do not see the selection you need in the drop -down options, please contact the WSU Energy Program at energycode@energy.wsu.edu or (360) 956-2042 for assistance. Project Information Edmonds plan Heating System Type: O All other Systems Contact Information * Heat Pump To see detailed instructions for each section, place your cursor on the word "Instructions" Design Temperature Instructions Edmonds Area of Building Conditioned Floor Area Instructions Conditioned Floor Area (sq ft) Average Ceiling Height Instruction Average Ceiling Height (ft) Glazing and Doors Instructions U-0.25 � Skylights Instructions Insulation Attic Instructions R-49 1 Single Rafter or Joist Vaulted Ceilings Instructions R-38 Vented � Above Grade Walls (see Figure 1) Instructions R-21 Intermediate Floors Instructions ( i l - R 38 J Below Grade Walls (see Figure 1) Instructions I R-10 Continuous Exterior Slab Below Grade (see Figure 1) Instructions R-21 int Plus R-5 ci � Slab on Grade (see Figure 1) Instructions R-10 Perimeter V, Location of Ducts Instructions Unconditioned Space Figure 1. Above Grade Below Grade Design Temperature Difference (AT) AT = Indoor (70 degrees) - Outdoor Design Temp 1,785 Conditioned Volume 9.1 16,244 U-Factor X Area = UA 0.250 659 164.75 U-Factor X Area = UA 0.50 --- U-Factor X Area = UA 0.026 2,537 65.96 U-Factor X Area UA 0.027 896 24.19 U-Factor X Area UA 0.056 1,885 105.56 U-Factor X Area UA 0.025 U-Factor X Area UA 0.064 889 56.90 F-Factor X Length UA 0.303 F-Factor X Length UA 0.540 Duct Leakage Coefficient 1.10 Sum of UA 417.36 W. Envelope Heat Load 19,199 Btu/Hour Sum of UA x AT Air Leakage Heat Load 8,070 Btu / Hour Volume x 0.6 x AT x 0.018 Building Design Heat Load 27,268 Btu / Hour Air leakage + envelope heat loss Building and Duct Heat Load 29,995 Btu / Hour Ducts in unconditioned space: sum of building heat loss x 1.10 Ducts in conditioned space: sum of building heat loss x 1 Maximum Heat Equipment Output 37,494 Btu / Hour Building and duct heat loss x 1.40 for forced air furnace Building and duct heat loss x 1.25 for heat pump (07/01/13)