Loading...
BLD2022-1195_Structural_Calculations_9.8.2022_2.02.51_PM_3097711structural ENGINEERS January 12, 2022 Unirac 1411 Broadway Blvd. NE Albuquerque, NM 87102 Attn.: Unirac - Engineering Department Re: Engineering Certification for the Unirac U-Builder 2.0 SOLARMOUNT Flush Rail PZSE, Inc. - Structural Engineers has reviewed the Unirac SOLARMOUNT rails, proprietary mounting system constructed from modular parts which is intended for rooftop installation of solar photovoltaic (PV) panels; and has reviewed the U- builder Online tool. This U-Builder software includes analysis for the SOLARMOUNT LIGHT rail, SOLARMOUNT STANDARD rail, and SOLARMOUNT HEAVY DUTY rail with Standard and Pro Series hardware. All information, data and analysis contained within are based on, and comply with the following codes and typical specifications: 1. Minimum Design Loads for Buildings and other Structures, ASCE/SEI 7-05, ASCE/SEI 7-10, ASCE/SEI 7-16 2. 2006-2018 International Building Code, by International Code Council, Inc. w/ Provisions from SEAOC PV-2 2017 3. 2006-2018 International Residential Code, by International Code Council, Inc. w/ Provisions from SEAOC PV-2 2017. 4. AC428, Acceptance Criteria for Modular Framing Systems Used to Support Photovoltaic (PV) Panels, November 1, 2012 by ICC-ES. 5. 2015 Aluminum Design Manual, by The Aluminum Association, 2015 Following are typical specifications to meet the above code requirements: Design Criteria: Ground Snow Load = 0 -100 (psf) Basic Wind Speed = 85 - 190 (mph) Roof Mean Height = 0 - 60 (ft) Roof Pitch = 0 - 45 (degrees) Exposure Category = B, C & D Attachment Spacing: Per U-builder Engineering report. Cantilever: Maximum cantilever length is L/3, where "L" is the span noted in the U-Builder online tool. Clearance: 2" to 10" clear from top of roof to top of PV panel. Tolerance(s): 1.0" tolerance for any specified dimension in this report is allowed for installation. Installation Orientation: See SOLARMOUNT Rail Flush Installation Guide. Landscape - PV Panel long dimension is parallel to ridge/eave line of roof and the PV panel is mounted on the long side. Portrait - PV Panel short dimension is parallel to ridge/eave line of roof and the PV panel is mounted on the short side. 1478 Stone Point Drive, Suite 190, Roseville, CA 95661 916.961.3960 916.961.3965 www.pzse.com 1 of 2 structurai ENGINEERS Components and Cladding Roof Zones: The Components and Cladding Roof Zones shall be determined based on ASCE 7-05, ASCE 7-10 & 7-16 Component and Cladding design. Notes: 1) U-builder Online tool analysis is only for Unirac SM SOLARMOUNT Rail Flush systems only and do not include roof capacity check. 2) Risk Category II per ASCE 7-16. 3) Topographic factor, kzt is 1.0. 4) Array Edge Factor Ye = 1.5 5) Average parapet height is 0.0 ft. 6) Wind speeds are LRFD values. 7) Attachment spacing(s) apply to a seismic design category E or less. Design Responsibility: The U-Builder design software is intended to be used under the responsible charge of a registered design professional where required by the authority having jurisdiction. In all cases, this U-builder software should be used under the direction of a design professional with sufficient structural engineering knowledge and experience to be able to: Evaluate whether the U-Builder Software is applicable to the project, and Understand and determine the appropriate values for all input parameters of the U-Builder software. This letter certifies that the Unirac SM SOLARMOUNT Rails Flush, when installed according to the U-Builder engineering report and the manufacture specifications, is in compliance with the above codes and loading criteria. This certification excludes evaluation of the following components: 1) The structure to support the loads imposed on the building by the array; including, but not limited to: strength and deflection of structural framing members, fastening and/or strength of roofing materials, and/or the effects of snow accumulation on the structure. 2) The attachment of the SM SOLARMOUNT Rails to the existing structure. 3) The capacity of the solar module frame to resist the loads. This requires additional knowledge of the building and is outside the scope of the certification of this racking system. DIGITALLY SIGNED If you have any questions on the above, do not hesitate to call. Prepared by: PZSE, Inc. — Structural Engineers Roseville, CA EXPIRES 08/02/2023 1478 Stone Point Drive, Suite 190, Roseville, CA 95661 916.961.3960 916.961.3965 www.pzse.com 2of2 2"X2" AHJ APPROVAL STAMP CAPSTONE SOLAR DESCRIPTION I DATE IDWG NO. ORIGINAL 1 2022-9-2 1 1 Solar Specialist DAVID NICOL System Engineer TIM WACHTMAN System Designer CASEY MILLER I Customer Info I VIC SUNG LAM & HERMAN HOY LAM 17806 73RD PLACE WEST EDMONDS, WA 98026 PARCEL# 00473700000800 Project Details 10.95 KW ROOFTOP PV SYSTEM TILT 1:12 PITCH AZIMUTH 253°/ 73° DC SYSTEM RATING 8.76 KW AC SYSTEM RATING 9.6KW ESTIMATED ANNUAL PRODUCTION 10,880 KWh/Yr EQUIPMENT: RACKING SYSTEM, ENGINEERING STAMP Sheet S-5 ENGINEERING REPORT Plan review * Distributed Dead Load 2.54 psf * Average Roof Point Dead Load 13.28 Ibs TOTAL NUMBER OF MODULES 30 TOTAL KW 10.95 KW TOTAL MODULE AREA -.596 ft2 Loads Used for Design BUILDING CODE ASCE 7-10 BASIC WIND SPEED 110.00 mph GROUND SNOW LOAD 25.00 psf SEISMIC (SS) 1.310 ELEVATION 310.00 ft WIND EXPOSURE B TOPOGRAPHICAL FACTOR KZT 1.00 VELOCITY PRESSURE, QZ 15.92 psf Loads Determined by Zip 98026 CITY, STATE Edmonds, WA BASIC WIND SPEED 110.00 mph GROUND SNOW LOAD 15.00 psf * Calculated based on suggested quantity given on part list Inspection PRODUCT MODULE MANUFACTURER MODEL MODULE WATTS MODULE LENGTH MODULE WIDTH MODULE THICKNESS MODULE WEIGHT EXPANSIONJOINTS RAILS DIRECTION BUILDING HEIGHT SHORTEST BUILDING LENGTH ROOF TYPE RAFTER SPACING • TOTAL WEIGHT MID CLAMP END CLAMP SOLARMOUNT FLUSH United Renewable Energy 30 - F6M365E7G-BB 365 watts 69.37" 41.26" 1.38" 43.21 Ibs Every 40' CROSS -SLOPE 30.00 ft 20.00 ft Other 24.00" 1513.80 Ibs Universal AF Clamp Universal AF Clamp Roof Area 1: Array 1 Landscape Modules - Rails Running Across Slope (for rails with attachments > 3) SOLARMOUNT LIGHT RAIL SPANS ZONE 1 ZONE 2 ZONE 3 MAXIMUM POINT LOADS [LBS] ZONE 1 ZONE 2 ZONE 3 [IN] Up -67.4 -127.9 -204.2 DESIGN SPAN 48 48 48 Down 178.1 178.1 178.1 Max Cantilever 16 16 16 Downslope 22.0 22.0 22.0 Max Span 76 76 72 Lateral 15.1 15.1 15.1 ZONES ZONE ZONE ZONE Tributary Area [ft2] 6.9 6.9 6.9 NO OF RAILS 2 2 2 ROOF PITCH: 50 DESIGN PRESSURES [PSF] ZONE 1 ZONE 2 ZONE 3 Up -9.8 -18.6 -29.7 Down 25.9 25.9 25.9 Downslope 3.2 3.2 3.2 Lateral 2.2 2.2 2.2 Landscape Modules - Rails Running Across Slope (for rails with attachments <= 3) SOLARMOUNT LIGHT RAIL SPANS ZONE 1 ZONE 2 ZONE 3 MAXIMUM POINT LOADS [LBS] ZONE 1 ZONE 2 ZONE 3 [IN] Up -67.4 -127.9 -204.2 DESIGN SPAN 48 48 48 Down 178.1 178.1 178.1 Max Cantilever 16 16 16 Downslope 22.0 22.0 22.0 Max Span 76 76 72 Lateral 15.1 15.1 15.1 ZONES ZONE 1 ZONE 2 ZONE 3 Tributary Area [ft2] 6.9 6.9 6.9 NO OF RAILS 2 2 2 ROOF PITCH: 50 DESIGN PRESSURES [PSF] ZONE 1 ZONE 2 ZONE 3 Up -9.8 -18.6 -29.7 Down 25.9 25.9 25.9 Downslope 3.2 3.2 3.2 Lateral 2.2 2.2 2.2 2"XZ" AHJ APPROVAL STAMP L CAPSTONE SOLAR DESCRIPTION DATE DWG NO ORIGINAL 2022-9-2 ] Solar Specialist DAVID NICOL System Engineer TIM WACHTMAN System Designer CASEY MILLER Customer Info VIC SUNG LAM & HERMAN HOY LAM 17806 73RD PLACE WEST EDMONDS, WA 98026 PARCEL# 00473700000800 Project Details 10.95 KW ROOFTOP PV SYSTEM TILT 1:1 Z PITCH AZIMUTH Z53°/ 73° DC SYSTEM RATING 8.76 KW AC SYSTEM RATING 9.6KW ESTIMATED ANNUAL PRODUCTION 10,880 KWh/Yr Drawing EQUIPMENT: RACKING SYSTEM, SITE SPECIFIC ENGINEERING Sheet S-6