Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BLD2022-1195_Other_9.8.2022_2.02.45_PM_3097708
SCOPE OF WORK PROPOSED NEW 10.95 KW (DC ROOF MOUNTED PHOTOVOLTAIC (PV) SYSTEMITH FOLLOWING EQUIPMENT: (30) UNITED RENEWABLE ENERGY F6M365E7G-BB SOLAR MODULES z°xz° AHJ APPROVAL (17) APS DS3-S MICROINVERTERS ; ' _ STAMP UNIRAC SOLARMOUNT FLUSH RACKING SYSTEM a SITE SPECIFICATIONS ELECTRIC UTILITY PROVIDER: SNOHOMISH COUNTY PUD ELECTRIC SERVICE RATING: 200A ROOF MATERIAL: TPO .N 1 SEISMIC CATEGORY: D ASCE 7-10 WIND EXPOSURE CATEGORY: B CAPSTONE DEED 5 F SOLAR ASCE 7-10 WINODS (3 SEC GUST IN MPH) lr►- -RISK CATEGORY I: 100 -RISK CATEGORY II: 1 1 0 VUIt DESCRIPTION DATE DWG NO. -RISK CATEGORY III -IV: 1 15 ORIGINAL 2022-9-2 ASCE 7-05 WINDSPEED: 85 3-SEC PEAK GUST IN MPH) ASCE 7-93 WINDSPEED: 71 f FASTEST MILE IN MPH) CODE AUTHORITY Solar Specialist 2018 WASHINGTON STATE FIRE CODE (2018 IFC) i 2020 WAC 296-46B 2020 NEC, WITH WAC AMENDMENTS) DAVID NICOL 2018 WASHINGTON STATE ENERGY CODE 2018 IECC System Engineer 2018 WASHINGTON STATE BUILDING CODE (2018 IBC) 2018 WASHINGTON STATE RESIDENTIAL CODE - TIM V CHTMAN (2018 INTERNATIONAL RESIDENTIAL CODE, WASHINGTON System Designer AMENDMENTS 2018 WAC51-51-2300 SECTION M2301) 2018 WASHINGTON STATE PLUMBING CODE (2018 UPC) ; CASEY MILLER 2018 WASHINGTON STATE MECHANICAL CODE (2018 UP Customer Info SHEET INDEX 1�O _0VOL7_A1C NOTES VAC SUNG LAM L HERMAN HOY LAM 20.ltLLWIPINGGONGEALEDINWALLkNDGEILINGSPItGZSSnItLLDFINMETALGONDUIr. 2/, TWE 5ElSMlG DVAGlN6 AND ANGnOPAGE OF ELECTPICAL CONDUITS SHALL DE IN ACCOPDANCE WITH THE 17806 73RD PLACE WEST E D M O N DS, WA 98026 A-1 NOTES, INDEX, SITE INFO, PROJECT DATA, CODE °SMACNA`6U/D1_1Nf_'5 EI5MCPESrPAIN5OFMecnANlcAL5r5rEr5AND PLUMINGPIPING5Y5rEM5. PARCEL # 00473700000aoo 1, AN INVEPrEP OP AN AC MODULE IN AN INTEVACTIVE PYIOTOVOLTAIG 5Y5TEM SHALL AUTOMATICALLY DE-ENEP6/ZE lT5 OUTPUT ro THE CONNECTED ELECTPIGAL PVODUCTION AND 0157-PIPUTION NE7IWOPK UPON L055 OF VOL7A6E IN THAT 22, ALL OF rWE LISTED 5Y5TEM5 PEOUIPED TWAT rWE SEISMIC LATEPAL FORGE F INCLUDING CONSIDEPATION OF o^P AND ^P PE DETEPl71NED AT EACH LEVEL OF THE PUILDIN6 50 TWAT PEACE SPACING CAN PE CALCULATED, TWE D157_,0G7_ Project Details A-2 SITE PLAN 5Y5rE17 AND SHALL PEIMAIN IN TWAT STATE UNTIL THE ELEGTPICAL PVODUCTION AND D/ IDUTION NETINOPK VOLTA6E HA5 PEEN PESTOVED, (NEC 69056/) STPUGTUPAL EN6/NEEP CAN APPPOVETHE 5El5MIG LATEVAL FORGE DErEPMINATION, 25, AGOPY OF THE GWOSEN PPAGIN6 5Y5TEM(5) INSTALLATION GUIDE/MANUAL SHALL Of ON THE JOO 5/rE PPIOP TO 10.95 K W A-3 PV LAYOUT AND COMPONENT LOCATION 2, ALL EXNfP1OP ELEGTP1GAL MErALLIG TUPIN6(EMT) GONDUIr F/TT/N6 SHALL PE PAIN TI6HT THPEAD-LE55 STAPTIN6 THE INSTALLIN6 OF HAN6EP5 AND/OP PPACE5, GOMPPE55/ON TYPE 5, MODULES AND SUPPOPr STPUGTUPES SHALL PE 6POUNDE0 24,WHEN IN57-ALLIN6 DPILLED-IN ANGH0P5 AND/OP POWDEP DPIVEN PINS IN EXISTING NON-PPES7-PE55ED PEINFOPCED GONGPETE, USE GAPE AND GAUTION TO AVOID CUTTING OP DAMAGING THE PEINFOPCED DAPS WHEN ROOFTOP PV SYSTEM E-1 ELECTRICAL LINE DIAGRAM 4, NAMEPLArES SHALL PE PPOVIDED FOP ALL GIPW/rTS IN THE SEPVIGE DISTPIOUTION AND POWEP DlSrPIPUTION SWITCH OOAPD5, PANEL POAPD5, DISCONNECTING SWITCHES, TEPMINAL GAOINErS, ErC, ALL NAMEPLATES SHALL PE INS7AL1_IN6 THEM INTO EXISTING PPE-5TVE55ED GONGPETE TENDONS PY U5IN6 A NON-DESTPUGTA/E METHOD PPIOK TO INSTALLATION, EXEPGlSE EXTPEI7E GAPE AND GAUTION TO AVOID GUTTING OP DAMAGING THE TENDONS DUPING TILT E-2 LABELING INFORMATION PEPl7A1VENT1_Y ATTACHED AND PE OF SUFFIGIENT_ CAPACITY 7-0 WITWSTAND THEWEArnEP. INSTALLATION. MAINTAIN A MINIMUM GLEAPANCE OF ONE INGn PETINEEN rHE PEINFOPGEMENr AND rnE DPILLED-IN ANGHOV 5, JUNCTION PDX/COMPINEP PDX HAVE TO USE GOMPPE55ION TYPE SrPAIN PELIEF P05/TIONED FOP APPPOPPIATE WATEPVUNOrr, 25, THE WOPKIN6 GLEAPANCES APOUNO THE EXl57-IN6 ELEGTVICAL EOUIPMENr A5 WELL A5 THE NEW ELECTPICAL EOUIPMENrWILLPEMA1NrAINEDINAGGOPDANCfWIrnNEC 110,26, 1:12 PITCH AZIMUTH E-3 EQUIPMENT: PV MODULE SPECIFICATION SHEETS 6, GONDUIT PUNS SHALL PE PPOVIDEO Wlrn SUFFICIENrWEATHEPPPOOF PULL PDXES OP JUNGTION PDX/G0MPINEP PDXES PEP APPPOPPIATE NEC PEOUIPEMENrS, 26, GONDUGMP5 EXP05ED TO SUNLI6nr SWALL PE LISTED A5 SUNLl6 r PE5/STANr. (NEG 500.6 0/, 510.8 D) 2-. GPOUNDlN6 PU5HIN65 APE PEOUIPED APOUND PPE -PUNCHED CONCENTPIG KNOCKOUTS ON THE DO 5/DE OF THE 2 53- / 73- E-4 EQUIPMENT: INVERTER SPECIFICATION SHEETS 1SEEPPOVIDEDGUr5HEE5FOP APPIFYONALEQUIPMENT5PEG7EIGArIONS 5Y5TEM,(NEc25o,911) 8, WIPING MATEP/ALS SHALL PE 50I7-APLE FOP THE SUN EXP05UPE AND WET LOGATIONS, FIELD APPLIED PPOTEGTVE COAr1NG5APENOT- AGGEPrAPLE, 28TnE 6POUNDING ELEGTPODE GONDUGTOP MUST PE PPOTEGTED FPOM PHYSICAL DAMAGE IF SMALLEP THAN #6 GOPPEVWIPE (NEC 25o.64P) DC SYSTEM RATING EQUIPMENT: RACKING SYSTEM, ROOF S- 1, S-2 9, JUNGrION, PULL AND OUTLET PDXES LOGArED PENIND MODULES SHALL PE 50 INSTALLED THArTHEWIPING 29, 6VOUNDING ELEGTPODE GONDUGTQPWILL PE CONTINUOUS, EXCEPT FOP SPLICES OP JOlN75 Ar PU5PAP5 WIrnIN 8.76 KW ATTACHMENT CONTAINED IN TWEM CAN PE PENDEPED AGGE55IPLE DIPEGTLY OP PY DISPLACEMENT OF MODULECS) SEGUPED PY LISTED EOUIPMENT (NEC 250,64 G) PEI70VAPLE FASrENEPS AND CONNECTED DY A FLEX/PLE W/P/N6 SYSTEM, (NEG 69054) /0, IN AN UNDEP6POUND PHOTOVOLTAIC 5Y5TEM, TWE POWEP 50UPCE S�ALI- PE LAPELED WITS rnE FOLLOWING 50, PACEWAY FOP 5POUND/N6 ELEGTPODE GONDUGTOP SHALL PE PONDER Ar EACH END, (GEC, 250,64 (E) - WWEPE ALL rEPMINALS OF THE D15GONNEGTIN6 MEANS MAY PE ENEP6/ZED IN 7- OPEN P05 TION, A5/6N WILL PE AC SYSTEM RATING S-3 EQUIPMENT: RACKING SYSTEM, CLAMPS WAPNIN6 AT EACH JUNCTION PDX, COMPINEP PDX, DISCONNECT_ AND DEVICE WHEPE rWE UN5POUNDED GIPGUIr5 MAY PE EXP05ED DUPING SEPVIGE : "WAPNIN5 - ELECTPIC SWOCK HAZAPD. TWE CUPPENr GIPCUIT GONDUG7_0P5 OF 7_nl5 PPOVIDED WAPNIN6 OE THE HAZAPD PEP NEC 690,1154, EACH UNGPOUNDED GONDUGTOP OF THE MULT-N✓IPE PPANGH CIPGUIT WILL PE IDENTIFIED PPP PHASE AND SYSTEM PEP NEG2/0,5, 9.6 KW S-4 EQUIPMENT: RACKING SYSTEM, RAIL PWOTOVOLrA1CPOWEP5Y5TEMAPE UNOPOUNOEDPUTMAY OfENEP6/ZED WITH THE PESPEGr-TO OPOUNDDUE TO 52,CFCUlr50VEP250V7-05POUNDSHALLGOMPLYWITnNEG250,918250,92(P)ffI-AMG95.25097 ESTIMATED ANNUAL PRODUCTION LEAKAGE PATHS AND/OP GPOUND FAULTS." (NECE 690.55(F)) ll. ALL PWOTOVOLrAIG MODULES AND A550CIATED EQUIPIIENr AND WIPING MATEPIAL SHALL PE PPOTECTED FPOM ANY 55, DC CONDUCTOPS EITHEP DO NOT_ ENrEP rWE PUILDIN6 OP APE PUN IN METALLIG PAGEWAYS OP ENGL05UPE5 TO Tnt F/PSr ACCE55/PLE DC DlSCONNEGT-IN6 MEANS PEP NEC 69051(E), LAIC 95b9051(E) 1 0, 880 K W h/Yr S-5 EQUIPMENT: RACKING SYSTEM, ENGINEERING PWYSIGAL DAMAGE. 54. ALL METALLIG FPAME PAILS AND OTWEP CUPPENT CAPPYIN6 METALLIG COMPONENTS (GONDUIr, JUNCTION E PULL 12, ALL ELECTPICAL DEVICES AND UTILIZATION EQUIPMENT SHALL PE LISTED PY AN APPPOVED 7_E57 ING AGENCY. PDXES, PACEWAY, ETC) SHALL PE 50LIDLY 6POUNDED PEP TWE MANUFAGTUPEP'S INSTALLATION INSTPUGTIONS LAMC Drawing lS.OU7-D00P EGUIPMENr SHALL PE AT IEA5r NEMASP FATED. 14. ALL SPECIFIED WIPING /5 EASED ON rWE USE OF GOPPEP 95.69OP0.5 ff 55. 5GPEW5, NUTS, POLTS ff WA5nEP5 TnAr ArrAGH EOU/PMENr 6POUNDING LUGS SHALL PE STAINLESS STEEL I AMC 95.1102 (0). NOTES, INDEX, SITE INFO, E Q U I PM E NT: RACKING SYSTEM, SITE SPECIFIC S-6 15. COWPACTOP SHALL OPTON ELECTPIGAL PEPMITS AND SHALL COOPDINATE ALL INSPECr1ON, COMMl55/0N/NG AND ENGINEERING ACCEPTANCE WITH THE CI-ONI , UTILIrY GO. AND CITY INSPEG70P5 A5 NEEDED 16, DPANIN65 APE DIAGPAMMATIC ONLY, POUTING OF PACEWAYS 51-1ALL PE AT TnE OPTION OF TnE CONTP. AGTOP UNLESS OTWEVWI5ENOTEDAND SHALLPEGOOPDINATEDWITWOTWEP.TPADES. 56, NO PIPING, DUGrS OP EQUIPMENT FOPE16N 7-0 ELEGrPIGAL EQUIPMENT SHALL PE PEPMITTED TO PE LOCATED WITHIN THE DEDICATED SPACE APOVE T-HE ElEGTPICAL EQUIPMENT. 5-. AU_ FIELDINSTALLEDJUNGrION, PULL- AND OUrLErOGXEDLOCATEDPEHINDMODULESOPPANELSSHALLPE PROJECT DATA, CODE S-7 EQUIPMENT: RACKING SYSTEM, BILL OF MATERIALS 1-. IF DISrANGES OF GAPLE PUNS APE DIFFEPENF rnAN SHOWN, rWE CONTPACTOP SHALL NOTIFY ELECrPICAL EN6/NEEP 7-0 VALIDATE rWE WIPE SIZE. FINAL DRAWINGS WILL PE PED-LINED AND UPDATED AS APPPOPPIArE ACCESS/ME DIPEGTLY OP PY D1SPLACE17ENr OF A MODULE (5) OP PANEL (5) SEGUPED PY PEMOVAPLE FASrENEP5. 58. PEI70VAL OF A DWP-INTEVACTVE INVEPT EP OP OrnEP EQUIPMENT SHALL NOT_ DISCONNECT THE PONDING Sheet 18, WWENEVEP A DISCPEPANGY IN OUANTITY OF EOUIPMENT,, APl5E5 ON TWE DPANIN65 OP SPEGIFIGArIONS, rWE GONNECrION PETWEEN rWE 6POUNDING ELEGrPODE CONDUGTOP AND THE PWOTOVOLTAIG 50UPCE AND/OP OUTPUT CONTP. ACTOP SHALL PE PE5PON5/PLE FOP PPOVIDIN6 AND IN5r111-L1NG ALL MATEPIAL AND SEPVlGES PEOUIPED PY rWE CIPCUIT 6POUNDED CONDUCTOP.. STPICTESr CONDITIONS NOTED ON rnE DP. AWIN65 OP IN TnE SPECIFIGArIONS TO ENDURE COMPLETE GOIIPLIANGE 59. rWE POOP MOUNTED PWOTOVOLrAIG MODULES, PANELS, OP 50LAP VOLTAIC ROLL POOPING MATEVIAL SHALL HAVE AND LON6fVtrY OF rnE OPEPAPLE SYSTEMVEOUIRED PY rWE APGWITECr/ENGINEEP. TnE SAME OP PETTEP L157ED FIVE-VE5/STANCE EATING rWAN rWE PUILDING POOF-COVEPIN6 /7117-EP1AL. A-1 l9, ALL PPOCHUPES, OPEPATION MANUALS, GA7AL065, SHOP DPAWIN65, ErC, SHALL PE HANDED OVEP TO THE OWNEP'5 40, ALL POOF MOUNTED CONDUIT WILL PE A MINIMUM l" OFF THE ROOF SUPFACE, PEPPESENTATVE AT THE COMPLETION OP WOPK, t Mukilteo I •1 �J♦ RoZic, ff ,C hav ion/: a�vaA'.,.Paikland Park I- i I j ♦ i i. Lynnwood i I Edmonds Moeintlake — I i Woo dw.ay ` --:f Terrace r- Brier ///jjj r ARRAY I (20) UNITED RENEWABLE ENERGY F6M365E7G-BB SOLAR MODULES (10) APS DS3-S MICROINVERTERS *EVERY DS3-S MICROINVERTER WITH 1-2 SOLAR MODULES _J PLOT PI -AN WIM P00� PI -AN SCALE: 1 " = 32' / (1/32" = 1 ') PROPERTY LINE (APPROXIMATE - NOT FOR LEGAL USE) 58'-7" 44'-11" / 31'-6" AY 75'-11 " A-2 ' ° ARRAY 2 ° (10) UNITED RENEWABLE ENERGY F6M365E7G-BB o SOLAR MODULES ° (5) APS DS3-S MICROINVERTERS ° 21'-8*EVERY DS3-S MICROINVERTER WITH C 1-2 SOLAR MODULES o (E) AUTOMATIC TRANSFER SWITCH ° rr-- (N) SOLAR AC COMBINER PANEL (OUTSIDE) (N) SOLAR AC DISCONNECT (OUTSIDE) (E) UTILITY (NET) METER (E) MAIN SERVICE PANEL (INSIDE) S 0' 32' 64' Know what'sbelOW. SCALE: 1"=32' / (1/32"=1') Call before you dig. 1,19To �T �W 2"X2" AHJ APPROVAL STAMP CAPSTONE SOLAR DESCRIPTION DATE DWG NO. ORIGINAL 2022-9-2 1 Solar Specialist DAVID NICOL System Engineer TIM WACHTMAN System Designer CASEY MILLER Customer Info VIC SUNG LAM & HERMAN HOY LAM 17806 73RD PLACE WEST EDMONDS, WA 98026 PARCEL # 00473700000800 Project Details 10.95 KW ROOFTOP PV SYSTEM TILT 1:12 PITCH AZIMUTH 253°/ 73- DC SYSTEM RATING 8.76 KW AC SYSTEM RATING 9.6KW ESTIMATED ANNUAL PRODUCTION 10,880 KWh/Yr Drawinci SITE PLAN Sheet 1 P00)1::: PLAN,? t100U1-f5 A-3 SCALE: 1 " = 8' / (1/8" = 1 ') NOTE TO PV INSTALLERS: INSTALL ATTACHMENTS PER MANUFACTURER'S SPECIFICATIONS, REFER TO INSTALLATION GUIDE ON S-2. CONDUIT 3/4", TYP. ELECTRICIAN TO DETERMINE FINAL CONDUIT LOCATIONS IN FIELD (N) ATTACHMENT POINTS, SPACED NO MORE THAN 48" APART, LAG MOUNTED AND SEALED WITH CHEMLINK M-I OR DURALINK 50 SEALANT, PER MANUFACTURER'S SPECIFICATIONS, TYP 4'-8" r, 16'-2" T-8" — ARRAY 1 (20) UNITED RENEWABLE ENERGY F6M365E7G-BB SOLAR MODULES (10) APS DS3-S MICROINVERTERS *EVERY DS3-S MICROINVERTER WITH 1-2 SOLAR MODULES (E) AUTOMATIC TRANSFER SWITCH (INSIDE) (E) MAIN SERVICE PANEL (INSIDE) • Know what's below. Call before you dig. 16'-7" i MOUNTING CALCULATIONS A MOUNTING SYSTEM AND MANUFACTURER UNIRAC SOLARMOUNT FLUSH 8 TOTAL WEIGHT OF MODULES, RAILS, ATTACHMENTS, & OPTIMIZERS 1599.3 LES MODULE WEIGHT (43.21) X NUMBER OF MODULES 30 1296.3 LBS MICROINVERTER WEIGHT (5.7) X NUMBER OF MICROINVERTERS I5 85.5 LBS RACKING COMPONENTS 303.0 LBS C ATTACHMENTS WEIGHT (2.5) X NUMBER OF ATTACHMENTS 114 785.0 LBS D WEIGHT PER ATTACHMENT POINT (B/C( (POINT LOAD) NOT TO EXCEED 45 LBS 14.0 LBS E MAXIMUM RAIL CANTILEVER 16 IN F TOTAL SURFACE AREA OF PV MODULES 19.876 SO FT X MODULES 596.3 SO FT G DISTRIBUTED WEIGHT OF PV MODULE ON ROOF (B/P) (DEAD LOAD) 1599.30 LBS / 596.3 SQ FT 2.7 i PSF �o i 'ARRAY 2 (10) UNITED RENEWABLE ENERGY F6M365E7G-BB SOLAR MODULES (5) APS DS3-S MICROINVERTERS *EVERY DS3-S MICROINVERTER WITH �\ 1-2 SOLAR MODULES y �✓ (N) SOLAR AC COMBINER PANEL (OUTSIDE) (N) SOLAR AC DISCONNECT (OUTSIDE) (E) UTILITY (NET) METER E► RAFTERS, Z" X 4" @ 24" O.C., V.I.F. FLAT ROOF (- 1:1 Z PITCH), NO RIDGE, TYP. 0' 8' 16' SCALE: 1"=8' / (1/8"=1') Z"X2" AHJ APPROVAL STAMP CAPSTONE SOLAR DESCRIPTION DATE DWG NO. ORIGINAL 2022-9-2 Solar Specialist DAVID NICOL System Engineer TIM WACHTMAN System Designer CASEY MILLER Customer Info VIC SUNG LAM & HERMAN HOY LAM 17806 73RD PLACE WEST EDMONDS, WA 98026 PARCEL # 00473700000800 Project Details 10.95 KW ROOFTOP PV SYSTEM TILT 1:12 PITCH AZIMUTH 253°/ 73° DC SYSTEM RATING 8.76 KW AC SYSTEM RATING 9.6KW ESTIMATED ANNUAL PRODUCTION 10,880 KWh/Yr PV LAYOUT AND COMPONENT LOCATION Sheet A-3 CONDUIT WIRE RATING DERATE FOR TEMPERATIRE ISC WIRE VOLTAGE DROP CALCULATIONS RUN LENGTH AMPS VOLTAGE DROP VOLTAGE DROP % VOLTAGE AT LOAD A %" PVC SCHEDULE 40 CONDUIT (3) 6 AWG THWN-2 (Black, Red, White) (1) 8 AWG Cu Bond Conductor 6 AWG RATE 90°C = 75A TEMPERATURE DE -RATING @ 104°F = 0.91 75A x 0.91 = 68.25A 1 1.43A x 1.25 x 1 .4 = 17 .25 6 AWG OK IAW 2 x 12.9 x 50' = 1290 x 39.9A _ Vd = 26240 = 1.96 volts 50 39.9 1.96 0.82 238.04 (Green or bare) NEC 690.8 (B)(1) 2"X2" B %" PVC SCHEDULE 40 CONDUIT (3) 8 AWG THWN-2 (Black, Red, White) 11) 8 AWG ct Bond Conductor 8 AWG RATE 90°C =SSA TEMPERATURE DE -RATING @ 104°F = 0.91 SSA x 0.91 = SO.OSA 11.43A x 1.25 x 1 25 = 1786A 8 AWG OK IAW 2 x 12.9 x 50' = 1290 x 9.9A _ Vd = - 1.30 volts 50 39.9 3.12 1.30 236.88 (Green or bare) NEC 690.8 (B)(1) AHJ APPROVAL STAMP C Y4' EMT CONDUIT AWGtive, Negative) WN-2 I (Posit2) 10ive, ( (1) 8 AWG Cu Bond Conductor 10 AWG RATE 90°C = 40A TEMPERATURE DE -RATING @ 104°F = 0.91 40A x 0.91 = 36.4A 11.43A x 1.25 x 1.25 = 17'86A 10 AWG OK IAW Vd = 2 x 12.9 x 50' = 1290 x 13.3A = 1.65 volts 10380 50 13.3 1.65 0.69 238.35 (Green or bare) NEC 690.8 (13)(1) D PV WIRE IN FREE AIR MINIMUM 10 AWG Cu POSITIVE, BARE Cu EGC OR INSULATED EGC IN N OR THHN ICONDUIT (90° RATED) WIRE NEGATIVE CONDUIT (N)(1) BRANCH OF (10) UNITED RENEWABLE ENERGY F6M365E7G-BB, APS DS3-S MICROINVERTER MODULES CONNECTED IN PARALLEL, 5 MICROINVERTERS DC Input Power: 960 watts (up to two 480 watt solar (UP TO TWO MODULES PER MICROINVERTER) modules per microinverter) Maximum Input Voltage: 60 Vdc - MPPT Range: 22 to 48 Vdc 1 2 0 0 0 9 10 CONTROLLED CONDUCTORS(THIN CAPSTONE 30 SECONDITED ' NOT MORE THAN 30 VOLTS AND 240 VOLTAMPERES WITHIN 30 SECONDS OF RAPID SHUTDOWN INITIATION (N) SOLAR AC Maximum Input Current: 16 Adc THE ARRAY. COMBINER Maximum Output Current: 2.66 Aac per microinverter SOLAROUTSIDE ' NOT MORE THAN 80 VOLTS AND 240 VOLTAMPERES WITHIN 30 SECONDS OF RAPID SHUTDOWN INITIATION PANEL, 125A, 240V, Maximum Output Voltage: 264 Vac + - + - + - + - INSIDETHEARRAY. Limitations: I to 6 microinverter$ per 20A branch DESCRIPTION DATE DWG NO. (E) UTILITY METER MAIN LUG ONLY, Maximum Power Per String: 5760W per 20A branch r THE RAPID SHUTDOWN INITIATION IS PERFORMED BY EITHER DISCONNECTING THE AC FEED TO THE INVERTER, ORIGINAL 2022-9-2 1 BI-DIRECTIONAL NET (NET) OR NEMA 3R, UL DC CL 200, FM2S, 60Hz BY TURNING THE AC DISCONNECT SAFETY SWITCH TO THE OFF POSITION. LISTED, D ^� - O O O AC 1-PHASE, 3W, 120/240V ROOM FOR METER #: 1000606296 PHOTOVOLTAIC SYSTEM EQUIPPED WITH MINIMUM Solar Specialist p INVERTER -EMBEDDED AUTOMATIC, RAPID SHUTDOWN ELECTRICAL INSTALLATIONS (N)(1) BRANCH OF (10) UNITED RENEWABLE ENERGY F6M365E7G-BB, OF 6 BREAKERS WILL COMPLY WITH THE MODULES CONNECTED IN PARALLEL, 5 MICROINVERTERS DAVID NICOL REQUIREMENTS OF THE (UP TO TWO MODULES PER MICROINVERTER) 0 (N) SOLAR AC DISCONNECT. N.E.C. SEC 690 & 705 System Engineer VISIBLE, LOCKABLE, Note: 705.31 EXTERNALLY OPERABLE, Note: 705.12(B)(2)(3)(b) 1 2 0 0 0 9 10 TIM WACHTMAN Note: 312.6 & 312.8(A)(1) & (2) (N) SUPPLY 60A RATED, 50A FUSES, Note: 404.6 Exception System Designer SIDE TAP 240V, NEMA 3R, Note: 230.66 & 230.70(C) + _ + 20A UL LISTED, o A Note:310.15(3)(c) CASEY MILLER Note:250.24(B) Customer Info EATON DG222NRB Note:314.16 oC zoA 0C OCPD Note:690.12(C) G ' 0 0 o AC + + + VIC SUNG LAM & HERMAN HOY LAM 17806 73RD PLACE WEST (E) _ D EDMONDS, WA 98026 GENERATOR ROOFTOP PV CONDUCTORS TO A (N)(I) BRANCH OF (10) UNITED RENEWABLE ENERGY F6M365E7G-BB, PARCEL # 00473700000800 Project Details f l Line BE ]"ABOVE ROOFTOP AND MODULES CONNECTED IN PARALLEL, 5 MICROINVERTERS 10.95 KW lul PROTECTED FROM PHYSICAL (UP TO TWO MODULES PER MICROINVERTER) F 0 0 DAMAGE ' C' C WITHIN ARRAY BOUNDARY , ROOFTOP 20A B o D+ 3/4" CONDUIT. 1 2 0 0 0 9 10 TILT Load 1:12 PITCH + + + AZIMUTH (E) TT 253"/ 73° AUTOMATIC(E) MAIN SERVICE DC 0 0 0 °CAC DC SYSTEM RATING AC TRANSFER PANEL MAIN BONDING JUMPER L UEE + + 8.76 KW SWITCH 2O0A BUSBAR 8 AWG NEUTRAL BAR ALL ELECTRICAL MATERIALS & EQUIPMENT C D 30 TOTAL SOLAR MODULES W/ 15 TOTAL MICROINVERTERS AC SYSTEM RATING 200A MAIN OCPDHALL BE LISTED BY APPROVED TESTING LAB Cu,CMIN. 9.6 KW Module Information Inverter Specifications Conductor Calculation Interconnection Method ESTIMATED ANNUAL PRODUCTION PV MODULE: URE F6M365E7G-BB APS DS3-S UP TO 2 PV MODULES PER DS3-S ( ) MAX BRANCH AC CONDUCTOR AMPACITY: CONNECT NEW SOLAR CIRCUIT TO EXISTING 10,880 KWh/Yr 365W x 10 = 5840W/ 240V = 15.2 lA x 125% = 19.02A Drawing ELECTRICAL SYSTEM VIA SUPPLY/ LINE SIDE TAP; ELECTRICAL DATA PER MODULE (STC): RATED/MAXIMUM AC POWER OUTPUT: 640W APS DS3-S MAX OUTPUT CURRENT = LOAD SIDE OF NET METER AND SUPPLY SIDE OF MAXIMUM POWER - Pmax (Wp): 365 MAX. CONTINUOUS OUTPUT CURRENT: 2.66A@240V 2.66A x 5 = 13.3A x 125%= 16.63Ao MAIN SERVICE PANEL IAW 705.1 I (A)(B)(C)(D)(E), ELECTRICAL LINE DIAGRAM MAX.DC INPUT POWER: 480X2@240V /o 10 AWG Cu 90' RATED = 40A x 91 = 36.4A 230.82(6), 690.13, & 690.15 MAXIMUM POWER VOLTAGE -Vm PP (V)� 34.2 36.4A z 19.OZA OK TO INSTALL IAW NEC 690.8(B)(1-2) MAXIMUM POWER CURRENT - Impp (A): 10.68 MAX. INPUT VOLTAGE: 60V MAX AC CONDUCTOR AMPACITY: 200A RATED BUSBAR x 120% = 240A Sheet OPEN CIRCUIT VOLTAGE - Voc (V): 40.7 NOMINAL DC INPUT VOLTAGE: 22V-48V 39.9A MAXIMUM CONT. OUTPUT CURRENT 240A - 200A MAIN OCPD = 40A SHORT CIRCUIT CURRENT Isc (A): 11.43 MAX. INPUT CURRENT: 16AXo2@240V 39.9A x 125% = 49.88A 40A ALLOWABLE POWER SOURCE INTERCONNECTION MODULE EFFICIENCY: 19 77% CEC WEIGHTED EFFICIENCY: 96.5 /0 8 AWG Cu 90' = 55A x 91 % = 50.05A 49.88A MINIMUM - SUPPLY SIDE TAP REQUIRED E 1 MAX. EFFICIENCY: 97% 50.05A >! 49.88A OK TO INSTALL IAW NEC 690.8(B)(1-2) UTILITY/ AHJ (PHENOLIC) NEC 705.12(B)(3) MAXIMUM AC OPERATING CURREN MAXIMUM AC OPERATING VOLTAG NEC 690.13(B) & NEC 690.115(D) NEC 705.12(B)(3) AS REQUIRED IF PV INTERCONNECTION IS MADE TO SUPPLY SIDE OF SERVICE DISCONNECT POWER TO THIS BUILDING IS SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECT LOCATED AS SHOWN 0 G POINT OF SOLAR INTERCONNECTION & MAIN SERVICE PANEL (INSIDE) M SOLAR ARRAY ON ROOFTOP, TYP SOLAR AC DISCONNECT (OUTSIDE) UTILITY NET METER SERVICED BY QUALIFIED PERSONNEL ONLY NEC 690.31(G)(3) & (4) SYSTEM AC CIRCUIT CONDUCTORS. EXPOSED RACEWAYS, CABLE TRAYS & OTHER WIRING METHODS. COVERS OR ENCLOSURES OF PULL BOXES & JUNCTION BOXES. CONDUIT BODIES IN WHICH ANY OF THE AVAILABLE CONDUIT OPENINGS ARE UNUSED. LABELS OR MARKINGS SHALL BE VISIBLE AFTER INSTALLATION. REFLECTIVE WITH %" UPPERCASE, WHITE ON RED. EVERY SECTION OF THE WIRING SYSTEM SEPARATED BY ENCLOSURES, WALLS, PARTITIONS, CEILINGS, OR FLOORS. SPACING BETWEEN LABELS OR MARKINGS SHALL NOT BE MORE THAN 10' 2"X2" AHJ APPROVAL STAMP CAPSTONE SOLAR DESCRIPTION I DATE JDWG NO. ORIGINAL 1 2022-9-2 Solar Specialist DAVID NICOL System Engineer TIM WACHTMAN System Designer CASEY MILLER I Customer Info I ADYIfSNE I=ASiENED 5/6N5. VIC SUNG LAM & HERMAN HOY LAM - T-nf LAofL SYIALL of 5U1iAOL-f POP TYIE fw1p0N1-1ENiWnfpE IT- l5 /NSTALLfD. 17806 73RD PLACE WEST - WYIffff IN 7-l1/S G00f, ALL r1fl-0 APPLIED LAl3�L5, WAPNING5, AND EDMON DS, WA 98026 IIAPKIN65 SYIOULD COMPLY WITH AN--5/ Z535.4 [NEC 110,21(0) FlfL-D 11A7.'KIN51. PARCEL # 00473700000800 ADYI SN > AST�N D 5/6N5 MAY Of AGGEPTAOI-f IP PROP)Th'LY ADIIfYfD, VINYL 51GN5 5I1ALL Project Details DEWEA7-HEP;nE5/STANT [//-C 605]1.131 1, fILL fOUIPMfNT TO l�f L1577ED PY UL OP 0771ff WTI-, ANO L-AffLIffD POI' IT5 APPLICfi771ON, 2, ALL GONDUCTOPS 511ALL Of COPPEK', PfITff) rOP 600 V ANO 90 DEGPff C WET ,ffNV1PON1'1,ffNT, 3, WI IN6, CONDUIT AND PACfWAY511OUNTED ON POOI=TOPS 511t}L1- I3f POUTED D/PfCTLY T-01 AND LOCATTD fly CL05E ft5 PO551PL-f TO 7-t1f NEAP,ff5T P06f,111P, OP VALLEY, 4, WOPKIN6 CLEAPANCE5 APOUND tILL NEW AND EXISTING ELECTPICAI - fOUIPMENT 5i1f}LL COMPLY W17-11 NEC 110,26, 5, DPAWIN65 /NDICA7-f 7-t1f GfNffP L APPANGEl1fNT Ot� 5Y5T M5, CONTPACTOP St1ALL I=UPN1511 ALL NffCff5-'5APY OUTLETS, SUPPOPTS, FIrT1NG5 AND ACCff550I:l,ff5 TO FULI=ILL APPLlCA LE GODS AND 57 fAN0APDS, 6, Wllfff 51Zff5 OP JUNCTION OOXffS, PACEWAY5, FIND GONOUti5 APE NOT 5PfCll=IEO, 7WE CONT-PACTOP 5/1t}LL 51ZE 7-11fM ACCOPOINGLY, 7, t1LL WIPE 7-,ffP/'1/NAT-/ONS 5t1ALL PE APPPOPP1A7-ELY LA0ELED AND PEAOILY W5/pLE, 8, MODULE GPOUNOING CLIPS TO DE IN5Tt1L1-E0 DETWEEN MOOULf ffAl` if AND MODULE 5UPPOPT- PAII , PEP Tt1f GPOUNDING CLIP MANUFACT-UPEP'5 /NSTI'UCTION, 9, MODULE 5UPPOk r PA11- TO PE PONDER TO CONTINUOUS GOPPEP 6,E.C, VIA WEEP LUG OP 1L5CO GPL--4DP7- I -AY -IN LUG, 10, 7-t1 POLf11'liY 01- 7-t1f GPOUNOM GONDUGTOPS l5 NffGt}TIVf 10.95 KW ROOFTOP PV SYSTEM TILT 1:12 PITCH AZIMUTH 253°/ 73° DC SYSTEM RATING 8.76 KW AC SYSTEM RATING 9.6KW ESTIMATED ANNUAL PRODUCTION 10,880 KWh/Yr Drawinci LABELING INFORMATION Sheet E-2 =8=UNITED RENEWABLE ENERGY F6M_E7G-BB / 120 cells 345W - 365 W Mono -Crystalline PV Module URE modules use URE's state -of -the art cell cutting technologyand advanced module manufacturing experience. Key Features + Publicly Traded Taiwanese Company. Formed as the merger of four Cell and Module Manufacturers in 2018. All four founding companies (Neo Solar Power, Gintech, Solartech, NDF) were in existence since 2008 or earlier. + Over 40OMW Of Projects Installed in the United States. + 25 Year Output Warranty and 25 Year Product Guarantee IEEE I O� Q qR + Winner of Taiwan Excellence Award 7 Consecutive Years for Highest Efficiency Module. + Super All Black Design for High Profile Residential and Commercial Installations. + High Quality Solar Cell Technology allows URE to be a major international exporter to Solar Module manufacturers in the United States and Europe. UNITED RENEWABLE ENERGY Electrical Data Model - STC F6M345E7G-BB F6M350E7G-BB F6M355E7G-BB F6M360E7G-BB F6M365E7G-BB Maximum Rating Power (Pmax) [W] 345 350 355 360 365 Module Efficiency [%] 18.68 18.95 19.22 1950. 1977. Open Circuit Voltage (Voc) IV] 39.90 40.10 40.30 40,50 40.70 Maximum Power Voltage IV] 33.40 33.60 33.80 34.00 34.20 Short Circuit Current (Isc) [A] 11.13 11.19 11.26 11.35 11.43 Maximum Power Current [A] 10.33 1 10.42 10.51 10.59 10.68 'Standard Test Condi on (STC): Cell Temperature 25'C, Irradiance 1000 W/m', AM 1.5 `Values without tolerance are typical numbers.Measurement tolerance: ±3% Mechanical Data Item Specification Dimensions 1762 mm (L)t x 1048 mm (W)' x 35 mm (D)' / 69.37"(L)I x41.26"(W)I x1.38"(D)' Weight 19.6 kg / 43.21 Ibs Solar Cell Mono / 83 mm x 166mm Front Glass White toughened safety glass, 3.2mm thickness Frame Black anodized aluminum profile Junction Box IP >_67, 3 diodes Connectors Type MC4 Compatible Cable 1.2M (cable length can be customized), 4mm' Packaging Configuration 1 31 pcs Per Pallet, 806 pcs per 40' HQ container I : With assembly tolerance of ± 2 mm [ ± 0.08"I I : With assembly tolerance of ±0.8 mm ( ±0.03") Engineering Drawing (mm) FRONT VIEW' BACK VIEW A -A 8-111ounting Hole C-Mounting Hole Fsae 11 4 place 4 place 35 #UNITED RENEWABLE 0 ENERGY United Renewable Energy Co., Ltd. P_ Copyright ® 2021 URE Corp. All rights reserved For more information, please visit us at www.urecorp.com �.• ` Copyright ® 2021 URE Corp. All rights reserved Operating Conditions Item Specification Mechanical Load 5400 Pa Maximum System Voltage 1000 VDC Series Fuse Rating 20 A Operating Temperature -40 to 85 °C Temperature Characteristics Item Specificatio Nominal Module Operating Temperature 45 °C ± 2°C Temperature Coefficient of Isc 0.048 %/ °C Temperature Coefficient of Voc -0.27 % / °C Temperature Coefficient of Pmax -0.35 % / °C `Nominal module operating temperature (NMOT): Air mass AM 1.5, irradiance 80OW/m', temperature 20°C, windspeed 1 m/s. 'Reduction in efficiency from lOOOW/m'to 20OW/m' at 25"C: 3.5 ± 2%. Dependence on Irradiance 1000 w/w 10 8 800 W/m' a 6 600 W/m' u 4 400 w/m' 2 200 W/m' p 0 5 10 is z0 25 Voltage IV) Reliability with Warranty 30 35 40 45 Temperature 2VC 10°"' I Additional value from warranty i r I g� eox r $ t I t � I yes. For more information, please visit us at www.urecorp.com - UNITED RENEWABLE [oil• tiE01 it ENERGY {� ' For more information, please visit us at www.urecorp.com a Copyright m 2021 URE Corp. All rights reserved 2"X2" AHJ APPROVAL STAMP CAPSTONE SOLAR DESCRIPTION I DATE IDWG NO. ORIGINAL 1 2022-9-2 1 1 Solar Specialist DAVID NICOL System Engineer TIM WACHTMAN System Designer CASEY MILLER Customer Info VIC SUNG LAM & HERMAN HOY LAM 17806 73RD PLACE WEST EDMONDS, WA 98026 PARCEL # 00473700000800 Project Details 10.95 KW ROOFTOP PV SYSTEM TILT 1:12 PITCH AZIMUTH 253' / 73- DC SYSTEM RATING 8.76 KW AC SYSTEM RATING 9.6KW ESTIMATED ANNUAL PRODUCTION 10,880 KWh/Yr Drawing EQUIPMENT: PV MODULE SPECIFICATION SHEETS Sheet E-3 ' APsystems • A LT E N E R G Y P O W E R PRODUCT FEATURES Leading the Industry in Solar Microinverter Technology APsystems 3rd generation of dual microinverters are reaching unprecedented power outputs of 640VA or 768VA or 880VA to adapt to today's larger power module. With 2 independent MPPT, encrypted ZigBee signals, the DS3-S, DS3-L and DS3 benefit from an entirely new architecture and are fully backwards compatible with the QSl and YC600 microinverters. The innovative and compact design make the product lighter while maximizing power production. The components are encapsulated with silicone to reduce stress on the electronics, facilitate thermal dissipation, enhance waterproof properties, and ensure maximum reliability of the system via rigorous testing methods including accelerated life testing. A 24/7 energy access through Apps or web based portal facilitate remote diagnosis and maintenance. The DS3 series is interactive with power grids through a feature referred to as RPC (Reactive Power Control) to better manage photovoltaic power spikes in the grid. With a performance and an efficiency of 97%, a unique integration with 20% less components, APsystems DS3-S, DS3-L and D53 are a game changer to residential and commercial PV. WIRING SCHEMATIC 0= Input Data (DC) Recommended PV Module Power (STC) Range Peak Power Tracking Voltage Operating Voltage Range Maximum Input Voltage Maximum Input Current Output Data (AC) Maximum Continuous Output Power Nominal Output Voltage/Range0' Nominal Output Current Nominal Output Frequency/ Ranger Power Factor(Default/Adjustable) Maximum Units per 20A and 30A Branch02% AC Bus Cable Efficiency Peak Efficiency CEC Efficiency Nominal MPPT Efficiency Night Power Consumption Mechanical Data Operating Ambient Temperature Range Storage Temperature Range Dimensions (W x H x D) Weight DC Connector Type Cooling Enclosure Environmental Rating Features Communication (Inverter To ECU)0 Isolation Design Energy Management Warranty 04 DS3 1 DS3-1 D` 2"XZ" AHJ APPROVAL STAMP 250Wp-48OWp+ 265Wp-570Wp+ 300Wp-660Wp+ 22V-48V 25V-55V 32V-55V 16V-60V 16V-60V iOIL 26V-60V 60V 16A x 2 18A x 2 1=1 20A x 2 CAPSTONE 640VA 768VA 880VA SOLAR 240V / 211V-264V 2.66A 3.20A 3.7A DESCRIPTION DATE I 60Hz/59.3Hz-60.5Hz ORIGINAL 2022-9-2 0.99/0.7 leading...0.7 lagging 6/9 5/7 4/6 12AWG / 10AWG Solar Specialist DAVID NICOL 97% System Engineer 96.5% 99.5% TIM WACHTMAN 20mW System Designer CASEY MILLER -40°F to +149°F (-40°C to +65°C) -40°F to +185'F (-40°C to+85°C) 10.3" x 8.6" x 1.6" (262mm X 218mm X41.2mm) 5.7lbs(2.6kg) Staubli MC4 PV-ADBP4-S2&ADSP4-S2 Natural Convection - No Fans NEMA 6 Encrypted ZigBee High Frequency Transformers, Galvanically Isolated Energy Management Analysis (EMA) system 10 Years Standard ; 25 Years Optional Compliance Safety and EMC Compliance UL1741;CSA C22.2 No. 107.1-16;CA Rule 21 (UL 1741 SA); FCC Part15; ANSI C63.4; ICES-003; IEEE1547; NEC2014&NEC2017 Section 690.11 DC Arc -Fault circuit; Protection NEC2014&NEC2017 Section 690.12 Rapid Shutdown of PV systems on Buildings; NEC 2020 0 Nominal voltage/frequency range can be extended beyond nominal ifrequired by the utility. © All Rights Reserved Limits may vary. Refer to local requirements to define the number of microinverters per branch Specifications subject to change without notice please ensure you ore using the in your area. most recent update found at web : uso.APsystems. com • (1) Recommend no more than 80 inverters register to one ECU for stable communication. 0i4 Qd To be eligible for the warranty, APsystems microinverters need to be monitored 10 via the EMA portal. Please refer to our warranty T&Cs available on uso.APsystems.com. APsystems Meets the standard requirements EAR 600 Ericksen Ave NE, Suite 200 Seattle, WA 98110 \r ® for Distributed Energy Resources Tel : 844-666-7035 (UL 1741) and identified with the MOW apsystems.com c us CSA Listed Mark 2022/02/15 Rev1.3 I Customer Info I VIC SUNG LAM & HERMAN HOY LAM 17806 73RD PLACE WEST EDMONDS, WA 98026 PARCEL# 00473700000800 Proiect Details 10.95 KW ROOFTOP PV SYSTEM TILT 1:1 Z PITCH AZIMUTH Z53'/ 73' DC SYSTEM RATING 8.76 KW AC SYSTEM RATING 9.6KW ESTIMATED ANNUAL PRODUCTION 10,880 KWh/Yr EQUIPMENT: INVERTER SPECIFICATION SHEETS Sheet E-4 ® LII NK as ac + CA4EM Paten: #6,360,491 POLYMER INNOVATION The FastJack"' / Cheml-inkTM combination is waterproof and compatible with most roof types, making it the go -to flat roof solar and other rooftop equipment mounting solution for today's contractors. Waterproof I Low Cost I High Quality I Easy -to -Install ProSolar® COPYRIGHT PROFESSIONAL SOLAR PRODUCTS 2017: All information contained in this brochure is property of Professional Solar Products (PSP). FastJack` is a registered trademarks for PSP and are covered under U.S. patent #6,360,491. (v 1.0) LOW COST + EASY TO IVS'1'AI.1. )�a..stJack Commercial E-Series 1 4-1/2" Commercial FastJack E-Series (P/N: CFJE-450-18) 2 6" Commercial FastJack E-Series (P/N: CFJE-600-18) 3 8" Commercial FastJack E-Series (P/N: CFJE-800-18) 4 10" Commercial FastJack E-Series (P/N: CFJE-1000-18) 5 12" Commercial FastJack E-Series (P/N: CFJE-1200-18) Includes: 1-1/4" OD Solid Aluminum post with 3/8" Top Threaded, 2" E-base. Hardware sold separately. Packaged 18 per box 1-Part and M1 Ratios CFJE: (1) Tube 1-Part for (2) E-Curbs (1) Pouch 1-Part for (12) E-Curbs (1) Tube M-1 for (3) E-Curbs FJE: (2) Tubes 1-Part for (3) E-Curbs (1) Pouch 1-Part for (10) E-Curbs (1) Tube M-1 for (3) E-Curbs ProSolarO FastJack P4te� 16,360,491 Residential E-Series 1 3" FastJack E-Series (P/N: FIE-300-18) 2 4-1/2" FastJack E-Series (P/N: FJE-450-18) 3 6" FastJack E-Series (P/N: FJE-600-18) Includes: 1" OD Solid Aluminum Post and 1.5" OD E-base, 5/16" x 3-1/2" Lag screw, 3/8" SS Washer, and 3/8" x 3/4" SS Hex Bolt Packaged 18 per box C kEM LINK POLYMER INNOVATION 1 ChemLink 1-Part Pouch (P/N: A-ChemLink 1-Part Pouch) 2 ChemLink 1-Part 10.1oz Tube (P/N: A-ChemLink 1-Part) 3 ChemLink M-1 10.1oz Tube (P/N: A -Chem Link M-1) 4 ChemLink E-Curb (P/N: A-ChemLink 3" E-Curb) Round, 3" diameter, does not include M-1 adhesive/sealant or 1-Part sealant ChemLink Products Sold Individually and COPYRIGHT PROFESSIONAL SOLAR PRODUCTS 2017: All information contained in this brochure is prPR,&R(ftfg0"f9,gcts (PSP). FastJack' is a registered trademarks for PSP and are covered under U.S, patent #6,360,491. (v 1.0) 2"X2" AHJ APPROVAL STAMP CAPSTONE SOLAR DESCRIPTION I DATE DWG NO. ORIGINAL 2022-9-2 1 Solar Specialist DAVID NICOL System Engineer TIM WACHTMAN System Designer CASEY MILLER I Customer Info I VIC SUNG LAM & HERMAN HOY LAM 17806 73RD PLACE WEST EDMONDS, WA 98026 PARCEL# 00473700000800 Proiect Details 10.95 KW ROOFTOP PV SYSTEM TILT 1:12 PITCH AZIMUTH 253°/ 73- DC SYSTEM RATING 8.76 KW AC SYSTEM RATING 9.6KW ESTIMATED ANNUAL PRODUCTION 10,880 KWh/Yr EQUIPMENT: RACKING SYSTEM, ROOF ATTACHMENT Sheet S-1 CHEM LINK E-CURBrM SYSTEM POLYMER INNOVATION PENETRATION SEALS Technical Data Sheet Polyether Technology CSI Section No. 07 12 13 CHEM LINK Construction & Maintenance Telephone: 800-826-1681 Fax: 269-679-4448 353 E. Lyons Street Schoolcraft, MI 49087 www.chemlink.com Product Description E-Curb penetration seals replace old-style metal pitch pans with versatile, precast components and pourable sealants. CHEM LINK's E-Curb System can usually be installed in under 15 minutes and never requires flashing or mechanical attachment. E-Curbs are designed for use on granulated modified bitumen, asphalt and coal tar B.U.R. (built up roofing). E-Curbs are specified for PVC, EPDM, PIB, and TPO single ply roofing membranes. E-Curbs are highly versatile for sealing penetrations around solar panel mounts, HVAC, Electrical, and any type of structural supports. TPO Primer is required for use with TPO single -ply roof membrane. When installed properly, this system forms a durable, waterproof rubber seal around penetrations. An extended manufacture warranty against leaks is activated with submittal of a completed warranty card. Special Characteristics • Rapid installation - "Slip -fit" light weight curb design reduces labor significantly. • Excellent adhesion to most roofing materials. • No flashing or mechanical attachment required. • Service Temperature -40°F to 200°F (-40°C to 93°C) • 1-Part® accommodates movement and is suggested for use on all granulated membranes and details with excessive movement. • For sloped roof applications, substitute Dural -ink 50TM non -slump adhesive/sealant for 1-Part and M-10 Restrictions • Please contact customer service for application guidelines with temperatures below 32°F (00C). • Do not install if rain is anticipated within 4 hours. • Do not use on Hypalon or smooth APP modified bitumen membrane. For smooth APP, torch down a target of granulated APP before installation. • TPO Primer must be used for TPO applications. • Do not prime bonding surfaces with asphalt primer! • Do not use asphalt cement as a "night sealant." Use M-1 for this purpose. • E-Curb kits are designed to contain enough 1-Part to fill each curb with displacement in consideration. Refer to our penetration calculator under contractor resources at chemlink.com to verify volumes. Last Revision: 03/20/17 Document No. DS1350 E-Curb System Components - E-Curb exterior rings, straights, and corners. • M-1 Structural Adhesive/Sealant used for bonding the E-Curb components, sealing and priming the penetration. • 1-Part "moisture cure' pourable sealer, used to form a durable, water -tight seal around the roof penetration. US Patent No. RE41,586 E-Curb precast form components are composed of light weight nylon resin. The E-Curb is 2-inches high and is available in a variety of shapes and sizes. Standard sizes include bisected circular pieces with inside diameters of 3, 4, 5, 6 or 9 inches; corner pieces with a 2-inch radius; straight pieces in 3-inch or 8-inch lengths; and a 4.5" x 3.4" rectangle. The outer surface is impervious to ice, corrosion, UV (ultraviolet) light and ponding water. M-1 Structural Adhesive/Sealant is a durable, self- fixturing moisture cure mastic. Cartridges of M-1 are supplied in each E-Curb Kit. Components are also sold separately. 1-Part is a highly flexible, self -leveling moisture cure pourable sealer that eliminates mixing. It is also 100% solid rubber, has a very low VOC content, will not melt or shrink, and is resistant to deterioration. It is supplied in 10.1-oz and 28-oz cartridges or 1/2 gallon pouches. Unused sealant can be capped and reused. American fiNATKMCL W Architectural M IS Manufacturers nssoartrara � Association MEMBER 90012008 Step 1 Remove all previously applied caulk, mastic, cement, asphalt, and other contaminants from penetrations with a wire brush. Clean all smooth substrates with isopropyl or denatured alcohol. Brush away all gravel or loose granules. Seal the base of each penetration with M-1. Coat penetrations with M-1 to 3" above the roof line. Step 2 Hold a section of E-Curb, flat side up, and apply a 1/4" bead of M-1 to the entire bottom perimeter. Apply 1 additional 1/4" bead of M-1 down the center of the section. Do not tool the beads flat. Place the E-Curb section on the roof surface to form a half circle around the penetration(s). Press down firmly until M-1 extrudes from the outside edges. Step 3 Apply M-1 to the second section of E-Curb as described above. Place the second section of curb on the roof surface to form a circle with the first section. Press firmly in place until excess adhesive extrudes from the outside edges. Apply a bead of M-1 around the outside base of the installed E-Curb, and tool to form a smooth fillet. For non E-Curb penetrations seals, add M-1 to scarf joint surfaces and tool smooth. Step 4 Cut tip off 1-Part cartridge at widest point on plastic nozzle and pierce the foil seal. Insert into caulking gun and pump E-Curb full. When using a 1-Part pouch, remove cap, pour, squeeze out excess air, and reseal. Note: To provide an adequate rubber seal, maintain a 1" distance between penetrations and inside edge of the E-Curb. 2"X2" AHJ APPROVAL STAMP • CAPSTONE SOLAR i F ° DESCRIPTION DATE DWG NO. ORIGINAL 2022-9-2 I All properties described in this document are derived from testing conducted in laboratory conditions. Properties and performance will vary depending on environmental conditions and application technique. Test and evaluate to determine appropriate usage. Visit www.chemlink.com for the Safety Data Sheet, Technical Data Guides and full warranty for this product. LIMITED WARRANTY: CHEM LINK warrants this product's performance, provided it is properly stored and applied within 1 year. If this CHEM LINK material is proved to be defective, return remaining product and purchase receipt for refund or replacement of product exclusive of labor or cost of labor. This is the sole and exclusive remedy for defects or failure of this product. User must read and follow the direction of the current Technical Data Guide and SDS prior to product use. User determines suitability of product for intended use and assumes all risks. Manufacturer shall not be liable for damages (including consequential or incidental damages) in excess of the purchase price, except where such exclusion or limitation is prohibited by state law. THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, WRITTEN OR ORAL, STATUTORY, EXPRESS OR IMPLIED INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE; except for the above express warranty given by manufacturer, the product is sold with all faults. CHEM LINK SHALL NOT BE RESPONSIBLE FOR THE USE OF THIS PRODUCT IN A MANNER TO INFRINGE ON ANY PATENT OR ANY OTHER INTELLECTUAL PROPERTY RIGHTS HELD BY OTHERS. This warranty gives you specific legal rights, and you may also have other rights in the U.S. which vary from state to state. For warranty claim information, call 800-826-1681. CHEM lNK o . o � PnunFa,rvrvovnnnry �i . Solar Specialist DAVID NICOL System Engineer TIM WACHTMAN System Designer CASEY MILLER I Customer Info I VIC SUNG LAM & HERMAN HOY LAM 17806 73RD PLACE WEST EDMONDS, WA 98026 PARCEL# 00473700000800 I Proiect Details I 10.95 KW ROOFTOP PV SYSTEM TILT 1:12 PITCH AZIMUTH 253°/ 73° DC SYSTEM RATING 8.76 KW AC SYSTEM RATING 9.6KW ESTIMATED ANNUAL PRODUCTION 10,880 KWh/Yr EQUIPMENT: RACKING SYSTEM, ROOF ATTACHMENT Sheet S-2 PART # TABLE P/N DESCRIPTION 302045M UNIVERSAL AF MID CLAMP - MILL 302045D UNIVERSAL AF MID CLAMP - DIRK 302050M UNIVERSAL AF END CLAMP -MILL 302050D I UNIVERSAL AF END CLAMP - DIRK UNIVERSAL END CLAMP dmuUNIRAC 1411 BROADWAY BLVD. NE ALBUQUERQUE, NM 87102 USA PHONE: 505,242.6411 WWW.UNIRAC.COM UNIVERSAL MID CLAMP UNIVERSAL AF END CLAMP O 1y8" 13/16n -F- x 30mm to 46mm MODULE FRAME c PRODUCT LINE: SOLARMOUNT DRAWING TYPE: PART & ASSEMBLY DESCRIPTION: UNIVERSAL AF CLAMPS REVISION DATE: 9/28/2020 UNIVERSAL AF MID CLAMP 30mm to 46mm MODULE FRAME r---r DRAWING NOT TO SCALE m ALL DIMENSIONS ARE NOMINAL o Q PRODUCT PROTECTED BY � ONE OR MORE US PATENTS LEGAL NOTICE SHEET 2"XZ" AHJ APPROVAL STAMP CAPSTONE SOLAR DESCRIPTION DATE DWG NO. ORIGINAL 1 2022-9-2 1 1 Solar Specialist DAVID NICOL System Engineer TIM WACHTMAN System Designer CASEY MILLER I Customer Info I VIC SUNG LAM & HERMAN HOY LAM 17806 73RD PLACE WEST EDMONDS, WA 98026 PARCEL# 00473700000800 Proiect Details 10.95 KW ROOFTOP PV SYSTEM TILT 1:1 Z PITCH AZIMUTH Z53°/ 73° DC SYSTEM RATING 8.76 KW AC SYSTEM RATING 9.6KW ESTIMATED ANNUAL PRODUCTION 10,880 KWh/Yr EQUIPMENT: RACKING SYSTEM, CLAMPS Sheet S-3 BONDING SPLICE BAR 0 1 %" Oo Oo 0 �15/16" J 411 TYPICAL SPLICE BAR DETAIL 12"-� TYPICAL EXPANSION JOINT DETAIL PART # TABLE P/N DESCRIPTION 303019M BND SPLICE BAR PRO SERIES MILL 303019D BND SPLICE BAR PRO SERIES DRK OUNIRAC 1411 BROADWAY BLVD. NE ALBUQUERQUE, NM 87102 USA PHONE: 505.242,6411 WWW.UNIRAC.COM PRODUCT LINE: SOLARMOUNT DRAWING TYPE: PART & ASSEMBLY DESCRIPTION: BONDING SPLICE BAR PRO SERIES LREVISION DATE: 8/23/2018 5/16"-18 TYPE F THREAD CUTTING SCREWS INCLUDED DOTE THAT ONLY 2 SCREWS ARE USED AT AN EXPANSION JOINT. THE SPLICE BAR DOES NOT BOND ACROSS AN EXPANSION JOINT. SEE INSTALLATION GUIDE FOR INSTRUCTION. DRAWING NOT TO SCALE ALL DIMENSIONS ARE Ln NOMINAL Q cs PRODUCT PROTECTED BY ONE OR MORE US PATENTS LEGAL NOTICE SHEET V44" BOLT LOCATION 1 11/6" %" BOLT LOCATION PART # TABLE P/N DESCRIPTION LENGTH 315168M SM LIGHT RAIL 168" MILL 168" 315168D SM LIGHT RAIL 168" DRK 168" 315240M SM LIGHT RAIL 240" MILL 240" 315240D SM LIGHT RAIL 240" DRK 240" 1411 BROADWAY BLVD. NE ALBUQUERQUE, NM 87102 USA PHONE: 505.242,6411 WWW.UNIRAC.COM PRODUCT LINE: SOLARMOUNT DRAWING TYPE: PART DETAIL DESCRIPTION: LIGHT RAIL REVISION DATE: 9/11/2017 DRAWING NOT TO SCALE ALL DIMENSIONS ARE N NOMINAL a can PRODUCT PROTECTED BY ONE OR MORE US PATENTS LEGAL NOTICE SHEET 2"XZ" AHJ APPROVAL STAMP CAPSTONE SOLAR DESCRIPTION I DATE IDWG NO. ORIGINAL 1 2022-9-2 1 I Solar Specialist DAVID NICOL System Engineer TIM WACHTMAN System Designer CASEY MILLER I Customer Info I VIC SUNG LAM & HERMAN HOY LAM 17806 73RD PLACE WEST EDMONDS, WA 98026 PARCEL# 00473700000800 I Proiect Details I 10.95 KW ROOFTOP PV SYSTEM TILT 1:1 Z PITCH AZIMUTH Z53°/ 73° DC SYSTEM RATING 8.76 KW AC SYSTEM RATING 9.6KW ESTIMATED ANNUAL PRODUCTION 10,880 KWh/Yr EQUIPMENT: RACKING SYSTEM, RAIL Sheet S-4 structural ENGINEERS January 12, 2022 Unirac 1411 Broadway Blvd. NE Albuquerque, NM 87102 Attn.: Unirac - Engineering Department Re: Engineering Certification for the Unirac U-Builder 2.0 SOLARMOUNT Flush Rail PZSE, Inc. - Structural Engineers has reviewed the Unirac SOLARMOUNT rails, proprietary mounting system constructed from modular parts which is intended for rooftop installation of solar photovoltaic (PV) panels; and has reviewed the U- builder Online tool. This U-Builder software includes analysis for the SOLARMOUNT LIGHT rail, SOLARMOUNT STANDARD rail, and SOLARMOUNT HEAVY DUTY rail with Standard and Pro Series hardware. All information, data and analysis contained within are based on, and comply with the following codes and typical specifications: 1. Minimum Design Loads for Buildings and other Structures, ASCE/SEI 7-05, ASCE/SEI 7-10, ASCE/SEI 7-16 2. 2006-2018 International Building Code, by International Code Council, Inc. w/ Provisions from SEAOC PV-2 2017 3. 2006-2018 International Residential Code, by International Code Council, Inc. w/ Provisions from SEAOC PV-2 2017. 4. AC428, Acceptance Criteria for Modular Framing Systems Used to Support Photovoltaic (PV) Panels, November 1, 2012 by ICC-ES. 5. 2015 Aluminum Design Manual, by The Aluminum Association, 2015 Following are typical specifications to meet the above code requirements: Design Criteria: Ground Snow Load = 0 -100 (psf) Basic Wind Speed = 85 - 190 (mph) Roof Mean Height = 0 - 60 (ft) Roof Pitch = 0 - 45 (degrees) Exposure Category = B, C & D Attachment Spacing: Per U-builder Engineering report. Cantilever: Maximum cantilever length is L/3, where "L" is the span noted in the U-Builder online tool. Clearance: 2" to 10" clear from top of roof to top of PV panel. Tolerance(s): 1.0" tolerance for any specified dimension in this report is allowed for installation. Installation Orientation: See SOLARMOUNT Rail Flush Installation Guide. Landscape - PV Panel long dimension is parallel to ridge/eave line of roof and the PV panel is mounted on the long side. Portrait - PV Panel short dimension is parallel to ridge/eave line of roof and the PV panel is mounted on the short side. 1478 Stone Point Drive, Suite 190, Roseville, CA 95661 916.961.3960 916.961.3965 www.pzse.com 1 of 2 structurai ENGINEERS Components and Cladding Roof Zones: The Components and Cladding Roof Zones shall be determined based on ASCE 7-05, ASCE 7-10 & 7-16 Component and Cladding design. Notes: 1) U-builder Online tool analysis is only for Unirac SM SOLARMOUNT Rail Flush systems only and do not include roof capacity check. 2) Risk Category II per ASCE 7-16. 3) Topographic factor, kzt is 1.0. 4) Array Edge Factor Ye = 1.5 5) Average parapet height is 0.0 ft. 6) Wind speeds are LRFD values. 7) Attachment spacing(s) apply to a seismic design category E or less. Design Responsibility: The U-Builder design software is intended to be used under the responsible charge of a registered design professional where required by the authority having jurisdiction. In all cases, this U-builder software should be used under the direction of a design professional with sufficient structural engineering knowledge and experience to be able to: Evaluate whether the U-Builder Software is applicable to the project, and Understand and determine the appropriate values for all input parameters of the U-Builder software. This letter certifies that the Unirac SM SOLARMOUNT Rails Flush, when installed according to the U-Builder engineering report and the manufacture specifications, is in compliance with the above codes and loading criteria. This certification excludes evaluation of the following components: 1) The structure to support the loads imposed on the building by the array; including, but not limited to: strength and deflection of structural framing members, fastening and/or strength of roofing materials, and/or the effects of snow accumulation on the structure. 2) The attachment of the SM SOLARMOUNT Rails to the existing structure. 3) The capacity of the solar module frame to resist the loads. This requires additional knowledge of the building and is outside the scope of the certification of this racking system. DIGITALLY SIGNED If you have any questions on the above, do not hesitate to call. Prepared by: PZSE, Inc. — Structural Engineers Roseville, CA EXPIRES 08/02/2023 1478 Stone Point Drive, Suite 190, Roseville, CA 95661 916.961.3960 916.961.3965 www.pzse.com 2of2 2"X2" AHJ APPROVAL STAMP CAPSTONE SOLAR DESCRIPTION I DATE IDWG NO. ORIGINAL 1 2022-9-2 1 1 Solar Specialist DAVID NICOL System Engineer TIM WACHTMAN System Designer CASEY MILLER I Customer Info I VIC SUNG LAM & HERMAN HOY LAM 17806 73RD PLACE WEST EDMONDS, WA 98026 PARCEL# 00473700000800 Project Details 10.95 KW ROOFTOP PV SYSTEM TILT 1:12 PITCH AZIMUTH 253°/ 73° DC SYSTEM RATING 8.76 KW AC SYSTEM RATING 9.6KW ESTIMATED ANNUAL PRODUCTION 10,880 KWh/Yr EQUIPMENT: RACKING SYSTEM, ENGINEERING STAMP Sheet S-5 ENGINEERING REPORT Plan review * Distributed Dead Load 2.54 psf * Average Roof Point Dead Load 13.28 Ibs TOTAL NUMBER OF MODULES 30 TOTAL KW 10.95 KW TOTAL MODULE AREA -.596 ft2 Loads Used for Design BUILDING CODE ASCE 7-10 BASIC WIND SPEED 110.00 mph GROUND SNOW LOAD 25.00 psf SEISMIC (SS) 1.310 ELEVATION 310.00 ft WIND EXPOSURE B TOPOGRAPHICAL FACTOR KZT 1.00 VELOCITY PRESSURE, QZ 15.92 psf Loads Determined by Zip 98026 CITY, STATE Edmonds, WA BASIC WIND SPEED 110.00 mph GROUND SNOW LOAD 15.00 psf * Calculated based on suggested quantity given on part list Inspection PRODUCT MODULE MANUFACTURER MODEL MODULE WATTS MODULE LENGTH MODULE WIDTH MODULE THICKNESS MODULE WEIGHT EXPANSIONJOINTS RAILS DIRECTION BUILDING HEIGHT SHORTEST BUILDING LENGTH ROOF TYPE RAFTER SPACING • TOTAL WEIGHT MID CLAMP END CLAMP SOLARMOUNT FLUSH United Renewable Energy 30 - F6M365E7G-BB 365 watts 69.37" 41.26" 1.38" 43.21 Ibs Every 40' CROSS -SLOPE 30.00 ft 20.00 ft Other 24.00" 1513.80 Ibs Universal AF Clamp Universal AF Clamp Roof Area 1: Array 1 Landscape Modules - Rails Running Across Slope (for rails with attachments > 3) SOLARMOUNT LIGHT RAIL SPANS ZONE 1 ZONE 2 ZONE 3 MAXIMUM POINT LOADS [LBS] ZONE 1 ZONE 2 ZONE 3 [IN] Up -67.4 -127.9 -204.2 DESIGN SPAN 48 48 48 Down 178.1 178.1 178.1 Max Cantilever 16 16 16 Downslope 22.0 22.0 22.0 Max Span 76 76 72 Lateral 15.1 15.1 15.1 ZONES ZONE ZONE ZONE Tributary Area [ft2] 6.9 6.9 6.9 NO OF RAILS 2 2 2 ROOF PITCH: 50 DESIGN PRESSURES [PSF] ZONE 1 ZONE 2 ZONE 3 Up -9.8 -18.6 -29.7 Down 25.9 25.9 25.9 Downslope 3.2 3.2 3.2 Lateral 2.2 2.2 2.2 Landscape Modules - Rails Running Across Slope (for rails with attachments <= 3) SOLARMOUNT LIGHT RAIL SPANS ZONE 1 ZONE 2 ZONE 3 MAXIMUM POINT LOADS [LBS] ZONE 1 ZONE 2 ZONE 3 [IN] Up -67.4 -127.9 -204.2 DESIGN SPAN 48 48 48 Down 178.1 178.1 178.1 Max Cantilever 16 16 16 Downslope 22.0 22.0 22.0 Max Span 76 76 72 Lateral 15.1 15.1 15.1 ZONES ZONE 1 ZONE 2 ZONE 3 Tributary Area [ft2] 6.9 6.9 6.9 NO OF RAILS 2 2 2 ROOF PITCH: 50 DESIGN PRESSURES [PSF] ZONE 1 ZONE 2 ZONE 3 Up -9.8 -18.6 -29.7 Down 25.9 25.9 25.9 Downslope 3.2 3.2 3.2 Lateral 2.2 2.2 2.2 2"XZ" AHJ APPROVAL STAMP L CAPSTONE SOLAR DESCRIPTION DATE DWG NO ORIGINAL 2022-9-2 ] Solar Specialist DAVID NICOL System Engineer TIM WACHTMAN System Designer CASEY MILLER Customer Info VIC SUNG LAM & HERMAN HOY LAM 17806 73RD PLACE WEST EDMONDS, WA 98026 PARCEL# 00473700000800 Project Details 10.95 KW ROOFTOP PV SYSTEM TILT 1:1 Z PITCH AZIMUTH Z53°/ 73° DC SYSTEM RATING 8.76 KW AC SYSTEM RATING 9.6KW ESTIMATED ANNUAL PRODUCTION 10,880 KWh/Yr Drawing EQUIPMENT: RACKING SYSTEM, SITE SPECIFIC ENGINEERING Sheet S-6 DETAILED PARTS DESCRIPTION an ` Rail 315168D SM LIGHT RAIL 168" DARK 29 3 i Structural aluminum extrusion containing slots that accept module and roof attachment hardware, electrical bonding accessories, and splice bars. Splice 303019D BND SPLICE BAR PRO SERIES DRK 16 Dark anodized aluminum extrusion for joining adjacent lengths of rail to one another. Includes pre -assembled bolts. Uses 1/2" socket for 1-tool system install. Mid Clamp 302045D UNIVERSAL AF SERIES MID CLAMP DARK 38 Universal Aesthetic Fastener (Mid), Universal for modules between 30-46mm and features twist and lock installation, 1 tool install, UL2703 integrated bonding, and low profile It hardware and 1/2 module gap for optimal aesthetics. Made from Aluminum and Stainless Steel hardware. End Clamp 302050D UNIVERSAL AF SERIES END CLAMP DARK 44 It Universal Aesthetic Fastener (End), Universal for modules between 30-46mm without the use of spacers or extra parts, Features twist and lock installation, 1 tool install, UL2703 integrated bonding, and low profile hardware for optimal aesthetics. Clamps can be placed anywhere on the rail and rail can be cut flush with the clamp for optimal aesthetics. Made from Aluminum and Stainless Steel hardware, Caps are PC/ASA. Roof Attachment 304001 D L-FOOT SERRATED W/ T-BOLT, DRK 114 Angle bracket connecting rail to roof or roof mounting accessory with serration on both mounting surfaces. Lag bolts sold separately. e Microinverter Mounting 008013S MICRO MNT BND T-BOLT 1/4in x 3/4in SS 30 Attaches micro -inverter flange to beam using 3/4" x 1 /4" bonding T-Bolt. Grounding Lug (Weeb) 008002S GROUND WEEBLUG #1 11 For electrical bonding of PV modules and rails. Accepts one 14AWG to 6AWG or two 12 AWG to 10 AWG copper wires. Tin plated copper body, 1 /4" stainless steel fasteners. Conduit Mount 00822CM E-BOSS CONDUIT MOUNT COMP KIT 10 o Attach conduit mount directly to deck, using an included flashing and hardware or mounted to a rail or L-Foot using T-bolt. Accomodates both 1" and 3/4" conduit. 2"X2" AHJ APPROVAL STAMP CAPSTONE SOLAR DESCRIPTION I DATE JDWG NO. ORIGINAL 1 2022-9-2 Solar Specialist DAVID NICOL System Engineer TIM WACHTMAN System Designer CASEY MILLER Customer Info VIC SUNG LAM & HERMAN HOY LAM 17806 73RD PLACE WEST EDMONDS, WA 98026 PARCEL # 00473700000800 Project Details 10.95 KW ROOFTOP PV SYSTEM TILT 1:12 PITCH AZIMUTH 253°/ 73- DC SYSTEM RATING 8.76 KW AC SYSTEM RATING 9.6KW ESTIMATED ANNUAL PRODUCTION 10,880 KWh/Yr Drawing EQUIPMENT: RACKING SYSTEM, BILL OF MATERIALS Sheet S-7