BLD2022-1229+Site_Plan+9.15.2022_11.56.52_AM+3110572A I B I C I D I E I F I G I H AERIAL VIEW ELECTRICAL NOTES GENERAL NOTES 1. WHERE ALL TERMINALS OF THE 1. PRIOR TO THE COMMENCEMENT OF ANY DISCONNECTING MEANS MAY BE WORK, THE CONTRACTOR SHALL NOTIFY ENERGIZED IN THE OPEN POSITION, A THE DESIGNER OF ANY DISCREPANCIES SIGN WILL BE PROVIDED WARNING OF WITH THE DESIGN IN ANY CAPACITY. THE HAZARDS. (PER ART. 690.17) ESPECIALLY RECOMMENDATIONS, CODES, 2. EACH UNGROUNDED CONDUCTOR OF OR REGULATIONS &RULES OF THE THE MULTIWIRE BRANCH CIRCUIT WILL AUTHORITY HAVING JURISDICTION, WHICH BE IDENTIFIED BY PHASE AND SYSTEM. SUPERSEDED THE NEC. (PER ART. 210.5) 2. ALL DIMENSIONS TO BE VERIFIED BY 3. A NATIONALLY RECOGNIZED TESTING CONTRACTOR PRIOR TO COMMENCEMENT LABORATORY SHALL LIST ALL OF WORK. EQUIPMENT IN COMPLIANCE WITH 3. CONTRACTOR IS RESPONSIBLE FOR ALL ARTICLE 110.3. SAFETY PRECAUTIONS, OSHA ' 4. ALL WIRES SHALL BE PROVIDED WITH REQUIREMENTS ETC. FOR THE SITE, STRAIN RELIEF AT ALL ENTRY POINTS INCLUDING EXISTING SITE HAZARDS. INTO BOXES AS REQUIRED BY UL LISTING 4. SYSTEM IS GRID INTERACTIVE/INTERTIED 5. MODULE FRAMES SHALL BE GROUNDED VIA A UL LISTED POWER -CONDITIONING AT THE UL-LISTED LOCATION PROVIDED INVERTER. BY THE MANUFACTURER USING 5. SYSTEM HAS NO ENERGY STORAGE OF UL-LISTED GROUNDING HARDWARE. ANY KIND, OR UPS. 6. MODULE FRAMES, RAIL, AND POSTS 6. ALL SOLAR MOUNTING FRAMEWORK TO SHALL BE BONDED WITH EQUIPMENT BE GROUNDED. GROUND CONDUCTORS AND GROUNDED 7. FOLLOW MANUFACTURERS SUGGESTED AT THE MAIN ELECTRICAL PANEL. INSTALLATION PRACTICES AND WIRING 7. THE DC GROUNDING ELECTRODE CONDUCTOR SHALL BE SIZED SPECIFICATIONS. 8. ALL WORK TO BE IN COMPLIANCE WITH RESIDENCE PHOTO ACCORDING TO ARTICLE 250.166B & THE INTERNATIONAL BUILDING CODES. 690.47. (IBC) 9. ALL ELECTRICAL WORK TO BE IN VR jD, COMPLIANCE WITH THE NATIONAL ELECTRIC CODE (NEC). •+�,r� !D � All, �� r r � _ _ '� � Sys y�'c- •r.�`* { � � � , -- =- - 201i4 A 4 - 9/12/2022 STRUCTURAL ONLY SHEET INDEX PV 1 COVER PAGE PV 5 MOUNTING DIAGRAM PV 2 SITE PLAN PV 6 PLACARD 4 PV 3 ELECTRICAL DIAGRAM CUT SHEETS ATTACHED PV 4 CHIKO MOUNTING DRAWN BY: DRAWING SCALE: CONFIDENTIAL - THE INFORMATION CONTAINED EMS CUSTOM IN THIS PACKET AND SUBSEQUENT CUTSHEETS Sandra Waller DESIGN DATE: 11 /09/2022 SO LG N SHALL NOT BE USED FOR THE BENEFIT OF ANYONE OUTSIDE SOLGEN POWER. NEITHER SOLGEN POWER 5100 ELM RD, E SHALL IT BE DISCLOSED TO OTHERS OUTSIDE PASCO, WA 99301 1 P O W E R THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE P: 509-931-1663 19810 83rd PI. W, Edmonds, WA 98026 PAGE# RESPECTIVE EQUIPMENT, WITHOUT WRITTEN Pv 1 CONSENT FROM SOLGEN POWER. L9 V A I b I G I U N E RIIIIIIIIIIIIIII COMP. SHINGLE In= -3M n ROOF AREA: 1668Ft2 PV AREA: 372.89Ft2 ROOF %: 22.36% CONFIDENTIAL - THE INFORMATION CONTAINEI IN THIS PACKET AND SUBSEQUENT CUTSHEET: SO LG E. N SHALL NOT BE USED FOR THE BENEFIT OF ANYONE OUTSIDE SOLGEN POWER. NEITHER SHALL IT BE DISCLOSED TO OTHERS OUTSIDE P O W E R THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT WRITTEN CONSENT FROM SOLGEN POWER. I ME INDEX: SYSTEM SIZE DC:7.03kW SYSTEM SIZE AC:5.70kW RAFTER SPACING: 24" O.C. NUMBER OF MODULES:19 RAFTER SIZE: 2" x 6" MODULE TYPE: SUNTECH STP370S-B60/WNHB INVERTER: Hoymiles Series MODULES = UTILITY METER O2 MAIN SERVICE O COMBINER BOX 0 AC DISCONNECTO SOLAR OFFSET=.+$ CIRCUIT 1 = SION `Lt 9/12/2022 CIRCUIT 2= STRUCTURAL ONLY DRAWN BY: DRAWING SCALE: 1 /8" = 1'-0" SOLGEN POWER Sandra Waller DATE: �� DESIGN 5100 ELM RD, 11 /09/2022 PASCO, WA 99301 P:509-931-1663 19810 83rd PI. W, Edmonds, WA 98026 PA Elm Im IIIIIIIIIIII0 mim A I b I (: LOAD CALCS - TOTAL AMPS AVAILABLE BUS RATING 120% TOTAL MAIN BREAKER MAX BREAKER SIZE 125A X 1.2 = 150 100A = 50A A COMBINER BOX PANEL SIZE CALCS CIRCUIT# NUMBER OF MODULES NUMBER OF MICROINVERTERS NOMINAL OUTPUT CURRENT TOTAL 125% TOTAL COMBINED TOTAL BREAKER SIZE CIRCUIT 1 (1 of 2) 2 1 X 2.46A = 2.46A x 1.25 = 3.08A - 15.58A = 20A CIRCUIT 1 (2 of 2) 8 2 5.OA = 10.00A x 1.25 = 12.50A CIRCUIT 2 1 of 2 1 1 1.23A = 123A 1.25 = 1. 4A = 14.04A = 15A CIRCUIT 2 2 of 2 8 2 5.OA = 10.00A x 1.25 = 12.50A NOTES: 1. 200A UTILITY METER GLOBE ONLY. (EXISTING) 2. 125A LOAD CENTER. (EXISTING) 3. 30A RATED NON -FUSED LOCKABLE AC DISCONNECT. (NEW) 4. 125A RATED COMBINER PANEL. (NEW) v ALL CONDUIT SIZES ARE MINIMUM SIZES ALL WIRE SIZES ARE FOR COPPER WIRE La V rL MAX AC OPERATING CURRENT CALCS FOR HM-1200 MAX AC OPERATING CURRENT FOR HM-1200, 600, 300 TOTAL # OF MICROINVERTERS MAX OUTPUT CURRENT MAX AC OPERATING CURRENT 4 X 5.OA = 20.00A HM-1200 HM-600 HM-300 MAX AC OPERATING CURRENT CALCS FOR HM-600 20.00A + 2.46A + 1.23A = 23.69A # OF MICROINVERTERS MAX OUTPUT CURRENT MAX AC OPERATING CURRENT 1 X1 2.46A = 2.46A MAX AC OPERATING CURRENT CALCS FOR HM-300 # OF MICROINVERTERS MAX OUTPUT CURRENT MAX AC OPERATING CURRENT 1 1XI 1.23A = 1.23A BREAKER SIZE CALCS MAX AC OPERATING CURRENT 125 % TOTAL BREAKER SIZE 23.69A x 1.25 x 29.61A = 30A 1 UTILITY METER (E) TO UTILITY GRID (E) IIIIIIIIIIII1IM (2)8 AWG 2 EXISTING (1)8 AWG EGC WIRE AIN SERVICE PANEL (E) (2)8 AWG 3 (1)8 AWG EGC I I 100A I 1 MAIN SERVICE DISCONNECT (E) W 2 SUNTECH STP370S-B60/WNHB MODULES 8 SUNTECH STP370S-B60/WNHB MODULES WITH HOYMILES HM-600 MICRO WITH HOYMILES HM-1200 MICRO INVERTERS INVERTERS (1 OF 2) (2 OF 2) L p (2)8 AWG (1)8 AWG EGC 30A LOAD -SIDE (2) (11 (81 ' ' ' (41 (31 (21 (11 SOLAR OCPD CIRCUIT #1 (Opposite end of the main disconnect on the busbar - NEC 705.12(B)(3) . . . (2)12 AWG (1)8 AWG EGC 7 A ti ti ti 1 SUNTECH STP370S-B60/WNHB MODULE 8 SUNTECH STP370S-B60/WNHB MODULES WITH HOYMILES HM-300 MICRO WITH HOYMILES HM-1200 MICRO INVERTER INVERTERS (1 OF 2) (2 OF 2) (11 (81 . . . (41 (31 (21 (�1 CIRCUIT #2 (2)12 AWG (1)8 AWG EGC n CP ti ti ti DRAWN BY: DRAWING SCALE: CONFIDENTIAL - THE INFORMATION CONTAINED EMS NOT TO SCALE IN THIS PACKET AND SUBSEQUENT CUTSHEETS Sandra Waller DATE: DESIGN SHALL NOT BE USED FOR THE BENEFIT OF SOLGEN POWER SO LG E. N ANYONE OUTSIDE SOLGEN POWER. NEITHER 5100 ELM RD, 11 /09/2022 SHALL IT BE DISCLOSED TO OTHERS OUTSIDE PASCO, WA 99301 P O W E R THE RECIPIENT'S ORGANIZATION, EXCEPT IN PAGE # CONNECTION WITH THE SALE AND USE OF THE P: 509-931-1663 19810 83rd PI. W, Edmonds, WA 98026 RESPECTIVE EQUIPMENT, WITHOUT WRITTEN PV 3 CONSENT FROM SOLGEN POWER. A 1 b 1 (; 59" SOL I RO( 1) IVIUUI IL 11 II UUA 11I IVVI JI IGQII III ly into existing rafters STRUCTURAL NOTES: 1. TOTAL WEIGHT (MODULE & RAIL): 929 LBS 2. RAIL WEIGHT: 78 LBS 3. MODULE WEIGHT: 851 LBS 4. DISTRIBUTED WEIGHT: 2.49 PSF o 'I O'i Oi 01 0 I L I t I r 1 (3 1 13.8' 3'5'' 0.67" FOOT o� LO �HIKO 1# Rail D 5mm x 60mm crews per RT inufacturer 14.24' 4' Mid Clamp Grounding Lug nd Clamp * 9/12/2022 STRUCTURAL ONLY DRAWN BY: DESIGN CONFIDENTIAL - THE INFORMATION CONTAINED EMS IN THIS PACKET AND SUBSEQUENT CUTSHEETS Sandra Waller DATE: SO LG E. N SHALL NOT BE USED FOR THE BENEFIT OF SOLGEN POWER ANYONE OUTSIDE SOLGEN POWER. NEITHER 5100 ELM RD, 11 /09/2022 SHALL IT BE DISCLOSED TO OTHERS OUTSIDE PASCO, WA 99301 PAGE # P O W E R THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE P: 509-931-1663 19810 83rd PI. W, Edmonds, WA 98026 RESPECTIVE EQUIPMENT, WITHOUT WRITTEN PV 4 CONSENT FROM SOLGEN POWER. IN I ICn ■ u ■ ■ u ■ ■ 1 is= -3m nIIIIIIIIIIII 1 IMOUNTING DIAGRAM ROOF TILT:18° AZIMUTH:95° CONFIDENTIAL - THE INFORMATION CONTAINED IN THIS PACKET AND SUBSEQUENT CUTSHEETS SO LG E N SHALL NOT BE USED FOR THE BENEFIT OF ANYONE OUTSIDE SOLGEN POWER. NEITHER SOLGEN POWER 5100 ELM RD, SHALL IT BE DISCLOSED TO OTHERS OUTSIDE PASCO, WA 99301 P O W E R THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE P: 509-931-1663 RESPECTIVE EQUIPMENT, WITHOUT WRITTEN CONSENT FROM SOLGEN POWER. PV MODULE - 16' MOUNTING FEET - CHIKO #7 RAIL 2 MOUNTING DIAGRAM SCALE: NOT TO SCALE STRUCTURAL NOTES: 1. 48" MAX SPAN OF RAIL TO DISTRIBUTE WEIGHT OVER SUPPORT OF TRUSSES 2. MOUNTING FEET ARE IN APPROXIMATE LOCATION. 3. MOUNTING FEET SHOULD BE STAGGERED AS SHOWN IN DIAGRAM * 9/12/2022 STRUCTURAL ONLY DRAWN BY: DRAWING SCALE: EMS 3/16" = V-0 Sandra Waller DATE: DESIGN 11 /09/2022 1 19810 83rd PI. W, Edmonds, WA 98026 1 PAGE` , ' MIN �M mim I� ■ L L3 i o. an Ei■ A■ CAUTION POWER TO THIS BUILDING IS SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: 19810 83rd PI. W, Edmonds, WA 98026 N VY• E S S 0 L G P O W SOLAR PV ARRAY WITH MICROINVERTERS ROOF MOUNTED ERVICE PANEL METER L�I,J"ONNECT SOLGEN P O W E R 6 "x6" O F.t 91 ■ ; Mw A CAUTION SOLAR ELECTRIC; SYSTEM CONNECTED ELC:. --.-A2ARD T?I:.. NL AryU LOFG TM EDUFMENTFED SY MJLTIPLE SOIIROES TOTAL MTING OF ALL OlERCUIOTEMT DEWES. EXCLUDING WI SUMY OVE-FICIUWAENT DEVICE SHALL NOT EXCEED /lMLCTTY OF SIISW DUAL POWER SUPPLY SOURCES. UT W Tv GRO AND PV y]I AR Ft FCTRIC SYSTEM SOLAR PV SYSTEM ' EQUIPPED WITH RAPID SHUTDOWN T0NNR1PID94X MM9VCNTO TIE'019'PIDSM011I709013 MN PVS%TEMANDRE0Jx SHOO RWM➢NTWARRAY Inside Panel CONFIDENTIAL - THE INFORMATION CONTAINE IN THIS PACKET AND SUBSEQUENT CUTSHEETS NOT BE USED FOR THE BENEFIT OF SOLGEN POWER C NSHALL ANYONE OUTSIDE SOLGEN POWER. NEITHER 5100 ELM RD, SHALL IT BE DISCLOSED TO OTHERS OUTSIDE PASCO, WA 99301 E R THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE P: 509-931-1663 RESPECTIVE EQUIPMENT, WITHOUT WRITTEN CONSENT FROM SOLGEN POWER. Enphase CombineSoladeck & Junction Boxes A CAUTION SOLAR CIRCUIT „ry Conduit: Every 1 0' A CAUTION SOLAR CIRCUIT PV SYSTEM kWh Meter ORWA-R—NING ELECTRIC SHOCK HAZARD TERMINALS ON THE UNEAND LOAD SIDES MAY BE ENERGIZED _..., IN THE OPEN POSITION AC Disconnect I, MiEOAC WIWICUY�II AV � vCN1VLOPHAl1M ACYR7AlE _ ! i AZARD iNf Mt) SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN R /M1il TLFN RAPID WEDOWN SWITCH TO THE'OFP POSITION TOSHUr DOWN I PISYs1Ey,ANDREDUCE $1ICCi HAZARD N Tf ARRAY DRAWN BY: DESIGN Sandra Waller DATE: EMS 11 /09/2022 PAGE # 19810 83rd PI. W, Edmonds, WA 98026 PV 6 ■IL ■M on, Elm 5SUNTECH Full Black Series 120 HALF -CELL ALL BLACK MONOFACIAL MODULE Features Certifications and standards: UL 61730 350-370 Watt High power output Compared to 158.75 mm half - cell module,the power output can increase 25 - 30 Wp Excellent weak light performance More power output in weak light condition, such as haze, cloudy, and morning Extended wind and snow load tests Module certified to withstand extreme wind (3800 Pascal) and snow loads (5400 Pascal) * Trust Suntech to Deliver Reliable Performance Over Time • World -class manufacturer of crystalline silicon photovoltaic modules • Unrivaled manufacturing capacity and world -class technology • Rigorous quality control meeting the highest international standards: ISO 9001, ISO 14001 and ISO] 7025 • Regular independently checked production process from international accredited institute/company • Tested for harsh environments (salt mist, ammonia corrosion and sand blowing testing: IEC 61701, IEC 62716, DIN EN 60068-2-68)** • Long-term reliability tests • 2 x 100% EL inspection ensuring defect -free modules Industry -leading Warranty based on nominal power 'g8% ind ustr yleading linear warranty 90% 81. ` �aao 1 10 25 • 98% in the first year, thereafter, for years two (2) through twenty-five (25), 0.55% maximum decrease from MODULE's nominal power output per year, ending with the 84.8% in the 25th year after the defined WARRANTY STARTING DATE.*** • 12-year product warranty • 25-year linear performance warranty Eta Intertek ST PXXXS - B60/Wn h b High PID resistant Advanced cell technology and qualified materials lead to high resistance to PID Suntech current sorting process System output maximized by reducing mismatch losses up to 2%with modules sorted & packaged by amperage Withstanding harsh environment Reliable quality leads to a better sustainability even in harsh environment like desert, farm and coastline Special Cell Design The unique cell design leads to reduced electrodes resistance and smaller current, thus enables higher fill factor. Meanwhile, it can reduce losses of mismatch and cell wear, and increase total reflection. IP68 Rated Junction Box The Suntech IP68 rated junction box ensures an outstanding waterproof level, supports installations in all orientations and reduces stress on the cables. High reliable performance, low resistance connectors ensure maximum output for the highest energy production. * Please refer to Suntech Standard Module Installation Manual for details. ** Please refer to Suntech Product Near -coast Installation Manual for details. *** Please refer to Suntech Product Warranty for details. NSUNTECH STC STPXXXS-B60/Wnhb Maximum Power at STC (Pmax) 370 W 365 W 360 W 355 W 350 W Optimum Operating Voltage (Vmp) 34.3 V 34.1 V 33.9 V 3_17 V 3_15 V Optimum Operating Current (Imp) ------------------------------------------------------------ ---- 10.79 A -------------- ----- 10.71 A 10.62 A ------------- ----------------- ----- 10.54 A ------------- ----- 10.46 A ------------------- Open Circuit Voltage (Voc) 40.9 V 40.7V 40.5 V 40.3 V 40.1 V Short Circuit Current (Isc) 11.49 A 11.42 A 11.35 A 11.28 A 11.21 A Module Efficiency 20.3% 20.0% 19.7% 19.5% 19.2% ----Operating----Module---Temperature-- --------------------------------------------------- ----------------------------------- -40 °C to +85 ------------------------------------------------------------ °C Maximum System Voltage 1000 V DC (IEC) Maximum Series Fuse Rating 20 A PowerTolerance 1 0/+5 W STC: Irradiance 1000 W/m2, module temperature 25 °C, AM=1.5; Tolerance of Pmax is within +/- 3%. N M OT STPXXXS-B60/W n h b Maximum Power at NMOT (Pmax) 278.2 W 274.3 W 270.7 W 266.8 W 263.3 W Optimum Operating Voltage (Vmp) 32.0 V 31.8 V 31.6 V 31.5 V 31.3 V Optimum Operating Current (Imp) ---------------------------------------------------------------- 8.69 A ------------------ 8.62 A ------------------ 8.56 A ------------------ 8.48 A ------------------ 8.42 A ------------------- Open Circuit Voltage (Voc) ------------------------------------------------------------------------------------------------------------------------------------------------------------------- 38.7 V 38.5 V 38.4 V 38.2 V 38.0 V Short Circuit Current (Isc) 9.17 A 9.10 A 9.04 A 1 8.96 A 8.89 A NMOT: Irradiance 800 W/m', ambient temperature 20 °C, AM=1.5, wind speed 1 m/s. 6- Temperature Characteristics Nominal Module Operating Temperature (NMOT) ----------------------------------------------------------------------------------------------- 42 ± 2 °C ------------------------ 4_2__±__2__oC Coefficient of Pmax ----------------------------------------------------------------------------------------------- -0.36%/°C --------------------------------------------------------------- Temperature Coefficient of Voc -0.304%/°C Temperature Coefficient of Isc 0.050%/oC Mechanical Characteristics ----Solar-----Cell MonocrystaIIine sil--------------------------------------------- ---------------------------------icon ----------166--------mm---------------------------------------------------- No. of Cells ----------------------------------------------------- 120 (6 x 20) -------------------------------------------------------------------------------------------------------- Dimensions 1756 x 1039 x 35 mm (69.1 x 40.9 x 1.4 inches) ___Weight -------------------------------------------------- kgs (44.8 lbs.) .3 ---------------------------------------------------------------------------------------------- -----20----- Front Glass 3.2 mm (0.13 inches) tempered glass Frame Anodized aluminium alloy Junction Box ------------------------------------------------------ IP68 rated (3 bypass- diodes) ------------ ------------------------------------------------------------------------------------------- Output Cables 4.0 mm2, Portrait: (-)350 mm and (+)160 mm in length Landscape: (-)1300 mm and (+)1300 mm in length or customized length Connectors MC4 compatible Container ---- Pieces - -per pallet --- ------------------- --- Pa---e-ts--p---e--r--c-o--n--t-a--i-n--e---r-------------- ----P--i-e--c-e---s--per c--o---n--t-a--i-n--e--r--------------- ----P--a--c--k-a--g---i-n--g---b--o--x---d--i-m----e--n--s-i-o---n--s---- Packaging box weight - 20'GP 40' HC 31 31 ------------------------------------------------- --------------------------------------------- ---- 6 26 186 806 1786 x 1130 x 1203 mm ----------------------------------------------------------------------------------------------------- 679 kg 1039[40.911±2[0.081 989[38.94i±1[0.041 Drainage holes B 4-05.1[00.2] Product label B Grounding hales 8-1400.55X0.35] Mounting slots Barcode Section A -A (Rear View) A�A 777 F m Junction box ± +1 +1 m m co � rn 35[1.38] y rn Section B-B 7 m 2010.791 Note:mm[inch] Current -Voltage & Power -Voltage Curve (370S) 10 0 350 300 250 200 y O a 150 100 50 0 0 30 20 30 40 50 Votage(V) 1 o00 W/m' � 800 W/m' � 600 W/m' � 400 W/m' � 200 W/m' Dealer information Information on how to install and operate this product is available in the installation instruction. All values indicated in this data sheet are subject to change without prior announcement.The specifications may vary slightly. All specifications are in accordance with standard EN 50380. Color differences of the modules relative to the figures as well as discolorations of/in the modules which do not impair their proper functioning are possible and do not constitute a deviation from the specification. 1IOL11TA1C25 Open Energy For All H M -300 N H M-350N H M-40ON Features M Easy installation, just plug and play With Reactive Power Control, compliant with CA Rule 21 Compliant with U.S. NEC-2017&NEC-2020 690.12 rapid shutdown Description Hoymiles 1-in-1 microinverter, which can be connected to one panel and used in various applications, is one of the most flexible solar solutions. With the maximum DC voltage of 60 V, Hoymiles microinverter is a PV Rapid Shutdown Equipment and conforms with NEC-2017 and NEC-2020 Article 690.12 and CEC-2021 Sec 64-218. All of the three models listed are equipped with reactive power control and are compliant with IEEE 1547, UL 1741 and CA Rule21. External antenna for stronger communication with DTU High reliability, NEMA 6 (IP67) enclosure, 6000 V surge protection hoymiles.com sales@hoymiles.com Technical Specifications Model HM-30ON HM-350N HM-40ON Input Data (DC) Commonly used module power (W) 240 to 405+ 280 to 470+ 320 to 540+ Maximum input voltage (V) 60 MPPT voltage range (V) 16-60 Start-up voltage (V) 22 Maximum input current (A) 11.5 11.5 12.5 Output Data (AC) Peak output power (VA) 300 350 400 Maximum continuous output power (VA) 295 349 382 Maximum continuous output current (A) 1.23 1.42 1.45 1.68 1.59 1.84 Nominal output voltage/range (V)' 240/211-264 208/183-228 240/211-264 208/183-228 240/211-264 208/183-228 Nominal frequency/range (Hz)' 60/55-65 Power factor (adjustable) >0.99 default 0.8 leading ... 0.8 lagging Total harmonic distortion <3% Maximum units per branch 13 11 11 9 10 8 Efficiency CEC peak efficiency 96.7% CEC weighted efficiency 96.5% Nominal MPPT efficiency 99.8% Nighttime power consumption(mW) <50 Mechanical Data Ambient temperature range (°C) -40 to +65 Dimensions (W X H X D mm) 182 X 164 X 29.5 Weight (kg) 1.98 Enclosure rating Outdoor-NEMA 6 (IP67) Cooling Natural convection - No fans Features Communication 2.4GHz Proprietary RF (Nordic) Monitoring S-Miles Cloud Warranty Up to 25 years Compliance UL 1741, IEEE 1547, UL 1741 SA (240 Vac), CA Rule 21 (240 Vac), CSA C22.2 No. 107.1-16, FCC Part 15B, FCC Part 15C PV Rapid Shutdown Conforms with NEC-2017 and NEC-2020 Article 690.12 and CEC-2021 Sec 64-218 Rapid Shutdown of PV Systems *1 Nominal voltage/frequency range can vary depending on local requirements. *2 Refer to local requirements for exact number of microinverters per branch. *3 Hoymiles Monitoring System. © 2021 Hoymiles Power Electronics Inc. All rights reserved. 1IOL11TA1125 open Energy For All H M -600 N H M -700 N H M -800 N Features Easy installation, just plug and play With Reactive Power Control, compliant with CA Rule 21 Compliant with U.S. NEC-2017&NEC-2020 690.12 rapid shutdown u Description Hoymiles 2-in-1 microinverter can connect up to 2 panels at once and maximize the PV production of your installation. With the maximum DC voltage of 60 V, Hoymiles microinverter is a PV Rapid Shutdown Equipment and conforms with NEC-2017 and NEC-2020 Article 690.12 and CEC-2021 Sec 64-218. All of the three models listed are equipped with reactive power control and are compliant with IEEE 1547, UL 1741 and CA Rule21. External antenna for stronger communication with DTU High reliability, NEMA 6 (IP67) enclosure, 6000 V surge protection hoymiles.com 91 sales@hoymiles.com Technical Specifications Model HM-60ON HM-70ON HM-80ON Input Data (DC) Commonly used module power (W) 240 to 405+ 280 to 470+ 320 to 540+ Maximum input voltage (V) 60 MPPT voltage range (V) 16-60 Start-up voltage (V) 22 Maximum input current (A) 2 X 11.5 2 X 11.5 2 X 12.5 Output Data (AC) Peak output power (VA) 600 700 800 Maximum continuous output power (VA) 590 696 766 Maximum continuous output current (A) 2.46 2.84 2.90 3.35 3.19 3.68 Nominal output voltage/range (V)' 240/211-264 208/183-228 240/211-264 208/183-228 240/211-264 208/183-228 Nominal frequency/range (Hz)' 60/55-65 Power factor (adjustable) >0.99 default 0.8 leading ... 0.8 lagging Total harmonic distortion <3% Maximum units per branch 6 5 5 4 5 4 Efficiency CEC peak efficiency 96.7% CEC weighted efficiency 96.5% Nominal MPPT efficiency 99.8% Nighttime power consumption (mW) <50 Mechanical Data Ambient temperature range (°C) -40 to +65 Dimensions (W X H X D mm) 250 X 170 X 28 Weight (kg) 3 Enclosure rating Outdoor-NEMA 6 (IP67) Cooling Natural convection - No fans Features Communication 2.4GHz Proprietary RF (Nordic) Monitoring S-Miles Cloud Warranty Up to 25 years Compliance UL 1741, IEEE 1547, UL 1741 SA (240 Vac), CA Rule 21 (240 Vac), CSA C22.2 No. 107.1-16, FCC Part 15B, FCC Part 15C PV Rapid Shutdown Conforms with NEC-2017 and NEC-2020 Article 690.12 and CEC-2021 Sec 64-218 Rapid Shutdown of PV Systems *1 Nominal voltage/frequency range can vary depending on local requirements *2 Refer to local requirements for exact number of microinverters per branch. *3 Hoymiles Monitoring System. © 2021 Hoymiles Power Electronics Inc. All rights reserved. lioL11TA11125 Open Energy For All 400M��q �) y H M-120ON H M-150ON a Features M Easy installation, just plug and play With Reactive Power Control, compliant with CA Rule 21 Compliant with U.S. NEC-2017&NEC-2020 690.12 rapid shutdown Description Hoymiles 4-in-1 microinverter is one of the most cost-effective module -level solar solutions, as it can support up to 4 panels at once and maximize the PV production of your installation. With the maximum DC voltage of 60 V, Hoymiles microinverter is a PV Rapid Shutdown Equipment and conforms with NEC-2017 and NEC-2020 Article 690.12 and CEC-2021 Sec 64-218. All of the three models listed are equipped with reactive power control and are compliant with IEEE 1547, UL 1741 and CA Rule21. External antenna for stronger communication with DTU High reliability, NEMA 6 (IP67) enclosure, 6000 V surge protection hoymiles.com sales@hoymiles.com Technical Specifications Model HM-120ON HM-150ON Input Data (DC) Commonly used module power (W) 240 to 405+ 300 to 505+ Maximum input voltage (V) 60 MPPT voltage range (V) 16-60 Start-up voltage (V) 22 Maximum input current (A) 4 X 11.5 4 X 11.5 Output Data (AC) Peak output power (VA) 1260 1200 1500 1350 Maximum continuous output power (VA) 1200 1109 1438 1246 Maximum continuous output current (A) 5 5.33 5.99 5.99 Nominal output voltage/range (V)' 240/211-264 208/183-228 240/211-264 208/183-228 Nominal frequency/range (Hz)' 60/55-65 Power factor (adjustable) >0.99 default 0.8 leading ... 0.8 lagging Total harmonic distortion <3% Maximum units per branch 3 3 2 2 Efficiency CEC peak efficiency 96.7% CEC weighted efficiency 96.5% Nominal MPPT efficiency 99.8% Nighttime power consumption (mW) <50 Mechanical Data Ambient temperature range (°C) -40 to +65 Dimensions (W X H X D mm) 280 X 176 X 33 Weight (kg) 3.75 Enclosure rating Outdoor-NEMA 6 (IP67) Cooling Natural convection - No fans Features Communication 2.4GHz Proprietary RF (Nordic) Monitoring S-Miles Cloud' Warranty Up to 25 years Compliance UL 1741, IEEE 1547, UL 1741 SA (240 Vac), CA Rule 21 (240 Vac), CSA C22.2 No. 107.1-16, FCC Part 15B, FCC Part 15C PV Rapid Shutdown Conforms with NEC-2017 and NEC-2020 Article 690.12 and CEC-2021 Sec 64-218 Rapid Shutdown of PV Systems *1 Nominal voltage/frequency range can vary depending on local requirements. *2 Refer to local requirements for exact number of microinverters per branch. *3 Hoymiles Monitoring System. © 2021 Hoymiles Power Electronics Inc. All rights reserved. W RT-MINI is suitable for mounting any rail system with a conventional L-Foot. Dual bolt design: M8 or 5/16" for L-Foot & 1/4" for E M C F.�y`-±1 LPL Easy tapping Z-rm or %-9mu �l screw. LMI : EN! LMI Installation Manual 1LA; Q! $ 0 ICC ESR 3575 a WTOTO" Flat lip for PV Cable clips 1100 Ah A 1/4" Hex Bolt i innnr channel M8 or 5/16" Hex Bolt bottom channel Engineered to ASTM D 1761 (Standard Test Methods for Mechanical Fasteners in Wood) Components Dimensions in (mm) RT2-00-M I N I B K 4 � }� 5 f �1 MINI base: 20 ea. Screw: 40 ea. Extra RT-Butyl : 10 ea. Optional item' 5 x 60mm Mounting screw (RT2-04-SD5-60) : 100 ea./Bag 5/16" Hex bolt, washer & nut set (RT-04-BN30sL-Us) : 100 ea./Bag RT-Butyl (RT2-04-BUTYLT) : 10 ea./Box RT-Butyl is Roof Tech s flexible flashing used in one million residential PV systems for the last 26 years. It is the first PV mounting system with Flexible Flashing certified by the ICC. Engineered to withstand wind speeds up to 180 mph and ground snow up to 90 psf. Metal Flashing Retrofit Flexible Flashing PPP'Shedding water? '- 100% Waterproof ICC ESR-3575 ASTM2140 testing UV testing (7500 hrs.) 0 CD `E 0 0 0 0 0 0 3 1 /2 (90 ) 2 (50) M� Rafter installation I Deck installation P.E. Stamped Letters available at www.roof-tech.us/support TAS 100 A on metal and asphalt roof. CHIKO Solar Mounting Solutions AL Roof Hook 019 CHIKO L Feet matching to the Flashing, supplying the best waterproofing solution for Asphalt Shingles Roofs. ADVANTAGES ■ Enables simple, fast and cost-effective installation. ■ High class anodized aluminium. ■ Fasteners and rail nut configurated to save extra parts purchasing. ■ 100% water proofing. UL LISTED UAc L us LISTED [PV MOUNTING SYSTEM] E483644 us c��TFo Intertek 5010190 Conforms to UL STD NO.2703 PRODUCT LINE Item Product Name CK-FTH-21 1 CHIKO AL Roof Hook 211 TECHNICAL DATA Main Material Uplift P Wind Load Snow Load Hook Spacing Installation Site 221 6005-T5 & SUS304 N*Fv (N=3) Up to 60 M/S 1.4 KM/M2 Up to 2000mm Roman Tile Roof COMPONENT LIST MATERIAL QTY AL Flashing 01 AL L Feet 01 050 Nut 01 SUS Bolt M8*25 01 SUS M8 Wahser 02 Wooden Screw M8*90 01 Silicon Rubber 01 ORDERING SPECIFICS Standard Packaging Dimensions Weight WARRANTY 16PCS/CTN 34X25X7CM 6KG CHIKO Solar Mounting Solutions 7 RAIL CHIKO 7R aluminium rail is designed for roof mounting system, it could applied on all roof mount system. ADVANTAGES ■ Easy installation ■ Highclass anodized ■ Tilt- in nut ■ Universal on roof mount system UL LISTED UAC L US LISTED [PV MOUNTING SYSTEM] E483644 C/STEO US Intertek 5010190 Conforms to UL STD NO.2703 PRODUCT LINE Item Product Name CK-7R-2100 CHIKO 7 RAIL 2100MM CK-7R-3200 CHIKO 7 RAIL 3200MM CK-7R-4200 CHIKO 7 RAIL 4200MM TECHNICAL DATA Main Material Wind Velocity Xi=31918.082 mm4 Yi=81501 .592 mm4 AL 6005-T5 Up to 60 M/S COMPONENT LIST MATERIAL QTY Aluminium Rail 01 ORDERING SPECIFICS Standard Packaging Dimensions Weight WARRANTY 8 PCS/PKG 1i 0 \ YEARS 2100/3200/4200mm 15/22.8/30KG CHIHO Solar Mounting Solutions 7 RAIL SPLICE KIT CHIKO 7R aluminium rail splice kit is designed for 7R rail connection from back to position. The most simple and handy installation way. ADVANTAGES Easy installation ■ Highclass anodized UL LISTED UAC L US LISTED [PV MOUNTING SYSTEM] E483644 Intertek 5010190 Conforms to UL STD NO.2703 PRODUCT LINE Item Product Name CK-FT-SKA CHIKO 7 Rail Splice Kit TECHNICAL DATA Main Material AL 6005-T5 Wind Load Up to 60 M/S Snow Load 1.4 KM/M2 COMPONENT LIST MATERIAL QTY Aluminium Rail Splice Kit 01 SUS304 Bolt M8*25 02 Star Washer 02 ORDERING SPECIFICS Standard Packaging Dimensions Weight ii 45.7mm n WARRANTY 10 \ YEARS 200 PCS/PKG 51 X38X22CM 30KG CHIKO Solar Mounting Solutions Intergated Grounding Mid Clamp CHIKO end clamps is designed base on 7R rail to fix module on the end of rail, have founction of intergated grounding, 30mm to 50 mm thickness module are available. ADVANTAGES Intergated Grounding ■ Easy installation ■ High class anodized ■ Tilt- in nut UL LISTED UAC L US LISTED [PV MOUNTING SYSTEM] E483644 us C/STEO Intertek 5010190 Conforms to UL STD NO.2703 PRODUCT LINE Item Product Name CK-FTM-K30 CHIKO Intergated Grounding Mid Clamp 30mm CK-FTM-K33 CHIKO Intergated Grounding Mid Clamp 33mm CK-FTM-K35 CHIKO Intergated Grounding Mid Clamp 35mm CK-FTM-K38 CHIKO Intergated Grounding Mid Clamp 38mm CK-FTM-K40 CHIKO Intergated Grounding Mid Clamp 40mm TECHNICAL DATA Main Material AL 6005-T5 D=30/33/35/38/40/45/5n COMPONENT LIST MATERIAL QTY Mid Clamp 01 SUS304 Bolt M8 01 050 SUS304 Nut 01 Rivet 02 ORDERING SPECIFICS Standard Packaging Dimensions Weight i!0J1 100 PCS/BOX 400PCS/CTN 50X38X20CM 26, 8/27.5/28/28.6KG CHIKO Solar Mounting Solutions Intergated Grounding End Clamp CHIKO end clamps is designed base on 7R rail to fix module on the end of rail, have founction of intergated grounding, 30mm to 50mm thickness module are available. ADVANTAGES ■ Intergated Grounding ■ Easy installation ■ High class anodized ■ Tilt- in nut UL LISTED UAC L US LISTED [PV MOUNTING SYSTEM] E483644 us C/STEO Intertek 5010190 Conforms to UL STD NO.2703 PRODUCT LINE Item Product Name CK-FTE-K30 CHIKO Intergated Grounding End Clamp 30mm CK-FTE-K33 CHIKO Intergated Grounding End Clamp 33mm CK-FTE-K35 CHIKO Intergated Grounding End Clamp 35mm CK-FTE-K38 CHIKO Intergated Grounding End Clamp 38mm CK-FTE-K40 CHIKO Intergated Grounding End Clamp 40mm TECHNICAL DATA Main Material AL 6005-T5 T 1=30/33/35/38/40/45/50 COMPONENT LIST MATERIAL QTY End Clamp 01 SUS304 Bolt M8*25 01 SUS304 Washer M8 01 050 SUS304 Nut 01 Rivet 01 ORDERING SPECIFICS Standard Packaging Dimensions Weight i!0J1 100 PCS/BOX 400PCS/CTN 50X38X20CM 22/24.5/25.5/26KG Sense Energy Monitor Technical Specifications Sense is a home energy monitoring device. It is used to measure current and voltage in the service mains and solar supply of your home. If installed outside, it must be kept dry and within specified temperature ranges. The Sense monitor should only be installed by a licensed electrician. Monitor (Monitor Model Nos. SM3, SM3S) Compatibility: 120VAC (90V-130V), 60 Hz Processor: 1 GHz ARM Wi-Fi: 2.4 GHz 802.11b/g/n Power Consumption: <5 watts, 0.1 amps ,I Dimensions: 5 3/8" H x 2 5/8" W x 1 1/4" D Weight: 220 g RH < 90%; Elevation < 3000 meters; Temperature: 0 - 500C Current Transformers CAT III, 300V, 200A max May be used on uninsulated conductors Dimensions: 3 6/16" H x 2" W x 12/16" D Inside Diameter: 1" Cable length: 46" Power Cable 16 AWG (UL), THHN or THWN, 600V. .OA Cable length: 14" Per UL requirements, the Sense energy monitor power cable itself is marked with all the required safety information, and compliance was verified as part of obtaining our safety certifications. It is jacketed with PVC to form a flexible power cord of UL type SVT, and marked as such. Certifications Certified to CSA STD C22.2 No. 61010-1 Conforms to UL STD 61010-1 Conforms to CAN ICES-3(B)/NMB-3(B) C OQS'FTV�S * s e n s e Intertek 5002148