BLD2022-1240_Manufacturer_Specifications_and_Installation_Instructions_9.14.2022_8.50.04_AM_3107286NR Product Data INDUSTRY LEADING FEATURES / BENEFITS A PERFECT BALANCE BETWEEN BUDGET LIMITS, ENERGY SAVINGS AND COMFORT. The MK series ductless split systems are a matched combination of an outdoor condensing unit and an indoor fan coil unit connected only by refrigerant tubing and wires. The fan coil is mounted under the ceiling or on the wall, near the ceiling. This selection of fan coils permits inexpensive and creative solutions to design problems such as: • Add-ons to current space (an office or family room addition) • Special space requirements • When changes in the load cannot be handled by the existing system. • When adding air conditioning to spaces that are heated by hydronic or electric heat and have no ductwork. • Historical renovations or any application where preserving the look of the original structure is essential. • The ideal compliment to your ducted system when it is impractical or prohibitively expensive to use ductwork. These compact indoor fan coil units take up very little space in the room and do not obstruct windows. The fan coils are attractively styled to blend with most room decors. Advanced system components incorporate innovative technology to provide reliable cooling performance at low sound levels. LOW SOUND LEVELS BUILT-IN RELIABILITY When noise is a concern, the ductless systems are the answer. The indoor units are whisper quiet. There are no compressors indoors, either in the conditioned space or directly over it, and there is none of the noise usually generated by air being forced through ductwork. When sound ordinances and proximity to neighbors demand quiet operation, the 24AHA4/25HHA4/124ANS/224ANS unit is the right choice: The advanced, horizontal blow -through airflow design distributes air more evenly over the coil. SECURE OPERATION If security is an issue, outdoor and indoor units are connected only by refrigerant piping and wiring to prevent intruders from crawling through ductwork. In addition, since 24AHA4/25HHA4/124ANS/224ANS units can be installed close to an outside wall, coils are protected from vandals and severe weather. FAST INSTALLATION This compact ductless split system is simple to install. A mounting bracket is standard with the indoor units and only wire and piping need to be run between indoor and outdoor units. These units are fast and easy to install ensuring minimal disruption to customers in the home or workplace. This makes the MK ductless split systems the equipment of choice, especially in retrofit situations. SIMPLE SERVICING AND MAINTENANCE Removing the top panel on outdoor units provides immediate access to the control compartment, providing a service technician access to check unit operation. In addition, the draw through design of the outdoor section means that dirt accumulates on the outside surface of the coil. Coils can be cleaned quickly from the inside using a pressure hose and detergent. On all indoor units, service and maintenance expense is reduced due to easy -to -access cleanable filters. In addition, these ductless systems have extensive self -diagnostics to assist in troubleshooting. Ductless split system indoor and outdoor units are designed to provide years of trouble -free operation. The indoor units include protection against freeze-up and high evaporator temperatures on heat pumps. The condensing units and heat pumps are also protected. There is a 3-minute time delay before the compressor will re -start. An oversized accumulator (Heat Pump), high pressure switches (or liquid line pressure switch on the heat pump), and compressor internal overload protection will ensure a reliable system that is ideal for light commercial applications. INDIVIDUAL ROOM COMFORT Maximum comfort is provided because each space can be controlled individually based on usage pattern. The air sweep feature provided permits optimal room air mixing to eliminate hot and cold spots for occupant comfort. In addition, year-round comfort can be provided with heat pumps. ECONOMICAL OPERATION The ductless split system design allows individual room heating or cooling when required. There is no need to run large supply -air fans or chilled water pumps to handle a few spaces with unique load patterns. In addition, because air is moved only in the space required, no energy is wasted moving air through ducts. EASY -TO -USE CONTROLS The ductless units have microprocessor -based controls to provided the ultimate in comfort and efficiency. The user friendly wireless remote control provides the interface between user and the unit. FLEXIBILITY A variety of accessories simplify the installation process and help meet system requirements and weather conditions. See Table 2 on page 4 for available accessories. AGENCY LISTINGS All systems are listed with AHRI (Air Conditioning, Heating & Refrigeration Institute)- 2 MODEL NUMBER NOMENCLATURE 40 MK 40 = FAN COIL UNIT MK = MODEL SYSTEM TYPE C = COOLING ONLY O = HEAT PUMP MAXIMUM NUMBER OF FAN COIL UNITS THAT CAN BE CONNECTED TO THE OUTDOOR UNIT B=1:1 NOMINAL CAPACITY 18 = 1— 1/2 TONS 24=2TONS 30=2-1/2TONS 34 = 2 — 5/6 TONS 36 = 3 TONS 48 = 4 TONS 54 = 4 1/2 TONS INDOOR UNIT C B 18 VOLTAGE 3 = 208/230-1 —60 NOT USED INDOOR FAN COIL TYPE F = Under Ceiling — Floor Console Use of the AHRI Certified TM Mark indicates a ANTTEk manufacturer's participation in the program For verification of certification for individual products, go to nPL ),IQ www.ahridirectory.org. C us J </STED STANDARD FEATURES AND ACCESSORIES Table 1— Standard Features and Accessories Ease Of Installation Indoor and Outdoor Compact Size S Outdoor Unit Wall Mounting Kit A Outdoor Unit Stacking Kit A Indoor Mounting Bracket S Comfort Features Convertible Under Ceiling - Floor Console S Microprocessor Cons S Wireless Remote Control S Automatic Air Sweep S Air Direction Control S Auto Restart Function S Cold Blow Protection On Heat Pumps S Turbo Mode S Follow Me S Energy Saving Features Sleep Mode S Stop/Start Timer S 46 ° F Heating Mode(Heating Setback S Safety And Reliability 3 Minute Time Delay For Compressor S Over Current Protection For Compressor S Crankcase Heater (standard on sizes 30 and 36 Heat Pump) A Indoor Coil Freeze Protection S Indoor Coil High Temperature Protection On Heat Pumps S Condenser High Temperature Protection On Heat Pumps S Accumulator On Heat Pumps S Ease Of Service And Maintenance Cleanable Filters S Diagnostics S Liquid Line Pressure Taps S Suction And Discharge Pressure Taps S Application Flexibility Law Ambient Controls (-20F) (-28.9C) A 3-Phase on sizes 34 & 54 (AC) and 36 & 48 (HP) S Wind Baffles A Condensate Pumps A Wired Controls A Legend S Standard A Accessory Table 2 — Optional Accessories Ordering No. Descriptions For Models KSACN0101AAA Wired Remote Control All Sizes 53DS-900 --- 118 Condensate Pump (230v) All Sizes KSALA0801AAA Low Ambient Control (for cooling - 20F) 24AHA4/25HHA4 (208/230V) KSALA0901AAA Low Ambient Control (for cooling - 20F) 24AHA4 (460V-3) KAACH1401AAA Crankcase Heater 24AHA4 Sizes 17-36 (208/230V) KAACH1501AAA Crankcase Heater 24AHA4 Size 36 (460V-3) KAACH1201AAA Crankcase Heater 24AHA4 Size 48 (208/230V) KAACH1901AAA Crankcase Heater 24AHA4/25HHA4 Size 48 (460V-3) KAACH1601AAA Crankcase Heater 25HHA4 Size 48 (208/230V) KAAWS0101AAA Winter Start Kit (for low ambient on cooling only systems) 24AHA4 All Sizes KHAIR0201AAA Isolation Relay (Required when using Low Ambient cooling with HP) 25HHA4 All Sizes KSAHS1501AAA Hard Start Kit (Capacitor & Relay) 24AHA4/25HHA4 (208/230V-1) 53DS-900 --- 087 Wind Baffle 24AHA4 Sizes 18 & 24 53DS-900 --- 071 Wind Baffle 24AHA4 Sizes 30-48 / 25HHA4 Sizes 30 & 36 53DS-900 --- 088 Wind Baffle 25HHA4 Size 48 53DS-900 --- 075 Stacking Kit 24AHA4 Sizes 18,24 53DS-900 --- 076 Stacking Kit 24AHA4 Sizes 30 - 48 53DS-900 --- 077 Wall Mount Kit 24AHA4 Sizes 18, 24 53DS-900 --- 078 Wall Mount Kit 24AHA4/25HHA4 Sizes 30 - 48 KAALS0201LLS Liquid Line Solenoid for Cooling Only 24AHA4 All Sizes - Required for Long Line Applications KHALSO401LLS Liquid Line Solenoid for Heat Pump 25HHA4 All Sizes -Required for Long Line Applications INDOOR UNIT ACCESSORIES Condensate Pump A07892 Fig. 1 — Condensate Pump Accessory On ductless fan coils, the condensate pump has a lift capability of 12 ft (3.6 m) on the discharge side with the pump mounted in the fan coil or 6 ft (1.8 m) on the suction side if the pump is remote mounted. The pump is recommended when adequate drain line pitch cannot be provided, or when the condensate must move up to exit. Wired Remote Controller For applications where the use of wireless remote control is not desired, the MK units can be controlled by means of a wired wall -mounted control with an LCD display. Fig. 2 — Wall Mounted Control with LCD Display OUTDOOR UNIT ACCESSORIES Low Ambient Kit Stacking Kit A fan -speed control device activated by a temperature sensor, designed to control condenser fan motor speed in response to the saturated condensing temperatures down to -20GF (-28.9GC), it maintains condensing temperature at -100F ± 1OF (37.8C ± 6C) A MotorMaster Low -Ambient Controller or Low -Ambient Pressure Switch must be used when cooling operation is used at outdoor temperatures below 55GF (12.8GC), and can be used on all outdoor units without changing the outdoor fan motor. Winter Start Control Stacking Kits allow stacking of equally sized smaller units to be stacked on top of larger units. NOTE: THIS KIT CANNOT BE USED PUMPS. The Winter Start Control is a SPST delay relay. The control bypasses the low pressure switch for approximately 3 minutes to permit start-up for cooling operation under low load conditions at a; low ambient temperatures. This relay is recommended on cooling only systems that have the accessory Low Ambient Kit. Isolation Relay MOUNTING FEET(6) BOLTED TO MOUNTING PAD The Isolation Relay must be used when Low Ambient Kit is used with heat pumps to ensure the pressure switch is bypassed when unit is running in heat pump mode. Liquid Line Solenoid Valve The Liquid Line Solenoid Valve is an electrically operated shut-off valve that is installed at the outdoor unit to stop and start refrigerant flow in response to compressor operation. The valve maintains a column of refrigerant in the liquid line between compressor operating cycles and is required for certain long line applications and to improve system performance. Crankcase Heater The Crankcase Heater is available for units with scroll compressors and clamps onto the compressor oil sump. It is recommended for low ambient applications. The Crankcase Heater is standard on sizes 30 and 36 Heat Pump. Wind Baffles The Wind Baffle is a sheet metal shield used to provide improved unit operation during high winds and is recommended whenever the low ambient accessory is used. N�TEN�man�.„�.mm , TWO UNITS MOUNTED (IDENTICAL SIZES) MOUN ING FEE IN STACKING RAII Fig. 3 — Stacking Kit Wall Mounting Kit units or permit WITH HEAT TWO UNITS MOUNTED (UNEQUAL SIZES) A06417 Wall mount brackets are mounted on the outside of the structure to raise the unit from ground level, or to mount the unit on a wall adjacent to a sloping roof. Wall mounts are also useful in areas of heavy snowfall or where space is at a premium. NOTE: Unit must be at least 6 in. (152.4 mm) from wall. D06006 Fig. 4 — Wall Mounting Kit DIMENSIONS - INDOOR Unit: Bracket: W Hook A0150266 Fig. 5 — 40MKCB**F, 40MKQB**F Unit and Bracket Dimensions Table 3 — Dimensions Indoor Indoor Unit Size BTU/Hr Height (H) in (mm) Width (W) in (mm) Depth (D) in (mm) Operating Weight I (kg) AC 18K 9.3(235) 42.0 (1068) 26.6 (675) 59.7 (27.1) 24K - 34K 9.3(235) 65.0 (1650) 26.6 (675) 91.9 (41.7) 54K 9.3(235) 65.0 (1650) 26.6 (675) 98.8 (44.8) HP 30K - 48K 9.3(235) 65.0 (1650) 26.6 (675) 98.8 (44.8) Bracket 18K AC 38.7 (983) 8.7(220) 24K - 54K AC/HP 61.6 (1565) 8.7(220) DIMENSIONS - OUTDOOR U AIR Im Fig. 6 - Outdoor Unit Dimensions Table 4 - Dimensions Indoor M I� FIELD POWER SUPPLY CONN. HOLE SIZES PROVIDED: t 0 7 /8. HOLE WITH 0 1 1/8" KNOCKOUT AND iONS 0 1 3/8" KNOCKOUT Dimensions in (mm) OPERATING WEIGHT UNIT A B C D E F G H J K L M N P Ibs.(kg) 24AHA418 31.1 36.9 14.6 16 23.4 17.2 23.1 28.1 13 6.6 11.3 0.6 2.9 5.8 146 (791) (938) (370) (406) (595) (437) (587) (713) (330) (168) (286) (16) (73) (148) (66) 24AHA424 31.1 36.9 14.6 16 23.4 17.2 23.1 28.1 14 6.8 11.6 0.8 2.9 5.8 148 (791) (938) (370) (406) (595) (437) (587) (713) (356) (171) (295) (19) (73) (148) (67) Cooling Only 37.1 44.5 17.1 18.4 30.5 19.6 29.1 34.1 13.7 8.1 15.9 0.8 3.4 6.4 183 24AHA430 (943) (1130) (433) (468) (775) (498) (740) (865) (348) (206) (403) (19) (86) (162) (83) 24AHA436 37.1 44.5 17.1 18.4 30.5 19.6 29.1 34.1 13.7 8.1 15.9 0.9 3.4 6.4 184 (943) (1130) (433) (468) (775) (498) (740) (865) (348) (206) (403) (22) (86) (162) (83) 24AHA448 37.1 44.5 17.1 18.4 30.5 19.6 29.1 34.1 14.5 8.5 18.9 0.9 3.4 6.4 213 (943) (1130) (433) (468) (775) (498) (740) (865) (368) (216) (479) (22) (86) (162) (97) HHA430 37.1 44.5 17.1 18.4 30.5 19.6 29.1 34.1 13.7 8.1 15.9 0.8 3.4 5.5 196 (943) (1130) (433) (468) (775) (498) (740) (865) (348) (206) (403) (19) (86) (140) (89) Heat Pump HHA436 37.1 44.5 17.1 18.4 30.5 19.6 29.1 34.1 13.7 8.1 15.9 0.9 3.4 5.5 197 (943) (1130) (433) (468) (775) (498) (740) (865) (348) (206) (403) (22) (86) (140) (89) HHA448 43.1 44.5 17.1 18.4 30.5 19.6 35.1 40.1 14.5 8.5 18.9 0.9 3.4 5.5 246 (1095) (1130) (433) (468) (775) (498) (892) (1018) (368) (216) (479) (22) (86) (140) (112) NOTE: Dimensions shown in feet -inches. Dimensions in O are millimeters. CLEARANCES - INDOOR Fig. 7 — 40MKCB**F, 40MKQB**F Unit Clearance CLEARANCES - OUTDOOR Fig. 8 — Outdoor Unit Clearance Table 5 — Clearances Air -outlet A0150267 A08436 UNIT Coil Facing Wall - in. (mm) Fan Facing Wall - in. (mm) A 24 (610) 24 (610) B 24 (610) 24 (610) C 20 (508) 6 (152) D 6 (152) 8 (203) E 6 (152) 20 (508) SPECIFICATIONS Table 6 - Specifications -Cooling Only Under Ceiling Systems Cooling Only Only Size 18 24 30 34 34 34 54 54 54 System Outdoor Model 24AHA418AO03 24AHA424AO03 24AHA43OA003 24AHA436AO03 24AHA436AO05 24AHA436AO06 24AHA448AO03 24ARA448AO05 24AHA448AO06 Indoor Model 40MKCB18F--3 40MKCB34F--3 40MKCB34F--3 40MKCB34F--3 40MKCB34F--3 40MKCB34F--3 40MKCB54F--3 40MKCB54F--3 40MKCB54F--3 Energy Star NO NO NO NO NO NO NO NO NO Cooling Rated Capacity Btu b 17,100 24,000 28,600 33,200 33,200 33,200 53,000 53,000 53,000 Performance SEER 14 14 14 14 14 14 14 14 14 EER 12.2 12.2 12.2 12.2 12.2 12.2 11.7 11.7 11.7 Controls Wireless Remote Controller ( F/ C Convertible) Standard Standard Standard Standard Standard Standard Standard Standard Standard Wired Remote Controller ( F/ C Convertible) Optional Optional Optional Optional Optional Optional Optional Optional Optional Operating Cooling Outdoor DB Min - Max F 55-125 (-20 F w / Low -Ambient Kit) Range Cooling Indoor DB Min -Max F 64-90 64-90 64-90 64-90 64-90 64-90 64-90 64-% 64-90 Total Piping Length Ft 200' 200' 200' 200' 200' 200' 200' 200' 200' Drop (OD above ID) Ft. 200' 200' 200' 200' 200' 200' 200' 200' 200' Lift (OD below ID) Ft. 65' 65' 65' 65' 65' 65' 65' 65' 65' Outdoor Pipe Connection Size - Liquid In. 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" Piping Outdoor Pipe Connection Size - Suction In. 5/8" 3/4" 3/4" 7/8" 7/8" 7/8" 7/8" 7/8" 7/8" Indoor Pipe Connection Size - Liquid In. 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" Indoor Pipe Connection Size - Suction In. 5/8" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 31,V Type R-410A R-410A R-410A R-410A R-410A R-410A R-410A R-410A R-410A Refrigerant Design Pressure PSIG 550 550 550 550 550 550 550 550 550 Metering Device Type B Acrurahx Charge Lb. 6.4 6.5 8.6 8.9 8.9 8.9 9 9 9 Face Area Sq. Ft 7.3 7.3 12.1 12.1 12.1 12.1 12.1 12.1 12.1 Outdoor Coil No. Rows 2 2 2 2 2 2 2 2 2 Fins per inch 20 20 20 20 20 20 20 20 20 Circuits 3 3 3 3 3 3 3 3 3 Face Area (sq. It) Sq. Ft. 2.5 4.1 4.1 4.1 4.1 4.1 4.35 4.35 4.35 Indoor Coil No. Rows 3 3 3 3 3 3 4 4 4 Fins per inch 19 19 19 19 19 19 19 19 19 Circuits 7 8 8 8 8 8 6 6 6 Compressor Type Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll Model ZP16K6E-PFV-130 ZP20K6E-PFV-130 ZP25K5E-PFV-130 ZP29K5E-PFV-130 ZP29K5E-TF5-130 ZP29K5E-TFD-130 ZP40K6E-PFV-130 ZP40K6E-TF5-130 ZP40K6E-TFD-130 Outdoor Voltage, Phase, Cycle V/Ph/ Hz 208230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-3-60 460-3-60 208/230-1-60 208/230-3-60 460-3-60 Indoor Voltage, Phase, Cycle V/Ph/ Hz 208230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 Power Supply Indoor and outdoor units have dedicatrd power supply Electrical MCA (Outdoor) A. 11.8 14.1 18.3 18.8 12.5 7.6 24.3 18.3 8.4 MO( P - Fuse Rating (Outdoor) A 20 25 30 30 20 15 40 30 15 MCA (Indoor) A. 3 3 3 3 3 3 3 3 3 MO( P - Fuse Rating (Indoor) A 15 15 15 15 15 15 15 15 15 Unit Width In. 36.9 36.9 44.5 44.5 44.5 44.5 44.5 44.5 44.5 Unit Height In. 31.1 31.1 37.1 37.1 37.1 37.1 37.1 37.1 37.1 Outdoor Unit Depth In. 14.6 14.6 17.1 17.1 17.1 17.1 17.1 17.1 17.1 Net Weight Lbs. 146 148 183 184 184 184 213 213 213 Airflow CFM 1,285 1,285 11900 2,615 2,615 2,615 2,615 2,615 2,615 Unit Width In. 42.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 Unit Height In. 9.3 9.3 9.3 9.3 9.3 9.3 9.3 9.3 9.3 Unit Depth In. 26.6 26.6 26.6 26.6 26.6 26.6 26.6 26.6 26.6 Net Weight Lbs. 59.7 91.9 91.9 91.9 91.9 91.9 98.8 98.8 98.8 Indoor Number of Fan Speeds 3 3 3 3 3 3 3 3 3 Airflow 0owest ta highest) CFM 405/515/695 975/1335/1130 975/1335/1130 975/1335/1130 975/1335/1130 975/1335/1130 1310/1400/1470 1310/1400/1470 1310/1400/1470 Sound Pressure (lowest in highest) dB(A) 4Z48/53 50/52t55 50/52t55 50/52t55 50/52t55 50/52/55 55/57/59 55/57/59 55/57/59 Air throw Data Ft 26 29 29 29 29 29 29 29 29 * Liquid line needs to be Insulated ** Refer to Ductless Split System Long Line Guide for additional information. Long Line accessories required beyond 80 ft (24.4 m). SPECIFICATIONS (CONT) Table 7 - Specifications - Heat Pump Under Ceiling Systems HEAT PUMP Size 30 36 36 36 48 48 48 System Outdoor Model 25HHA43OA003 224ANS030000 25HHA436AO03 224ANS036000 25HHA436AO05 224APS036000 25HHA436AO06 224AES036000 25HHA448AO03 224ANSO48000 25HHA448AO05 224APSO48000 25HHA448AO06 224AESO48000 Indoor Model 40MKQB36F--3 40MKQB36F--3 40MKQB36F--3 40MKQB36F--3 40MKQB48F--3 40MKQB48F--3 40MKQB48F-3 Energy Star NO NO NO NO NO NO NO Cooling Rated Capacity Btu/h 29,000 34,200 34,200 34,200 46,400 46,400 46,400 SEER 14 14 14 14 14 14 14 EER 11.5 11 11 11 11.7 11.7 11.7 Performance Heating Rated Capacity Btu/h 29,000 34,200 34,200 34,200 46,400 46,400 46,400 HSPF 8.2 8.2 8.2 8.2 8.2 8.2 8.2 COP W/W 4.1 4.1 4.1 4.1 3.8 3.8 3.8 Wireless Remote Controller (°F/°C Convertible) Standard Standard Standard Standard Standard Standard Standard Controls Wired Remote Controller (°F/°C Convertible) Optional Optional Optional Optional Optional Optional Optional Cooling Outdoor DB Min - Max °F 55-125 (-20°F w / Low -Ambient Kit) Operating Heating OutdoorDBMin - Max °F 17--75 17-75 17-75 17-75 17-75 17-75 17-75 Range Cooling IndoorDB Min -Max °F 64-90 64-90 64-90 64-90 64-90 64-90 64-90 Heating IndoorDB Min -Max °F 32-80 32-80 32-80 32-80 32-80 32-80 32-80 Total Piping Length Ft. 200' 200' 200' 200' 200' 200' 200' Drop (OD above ID) Ft. 200' 200' 200' 200' 200' 200' 200' Lift (OD below ID) Ft. 65' 65' 65' 65' 65' 65' 65' Piping Outdoor Pipe Connection Size - Liquid In. 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" Outdoor Pipe Connection Size - Suction In. 3/4" 7/8" 7/8" 7/8" 7/8" 7/8" 7/8" Indoor Pipe Connection Size - Liquid In. 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" Indoor Pipe Connection Size - Suction In. 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" Type R410A R410A R410A R410A R410A R410A R410A Design Pressure PSIG 550 550 550 550 550 550 550 Refrigerant Metering Device Type B Accurator Charge Lb. 12.1 12.3 12.3 12.3 10.95 10.95 10.95 Face Area Sq. Ft. 12.1 12.1 12.1 12.1 14.1 14.1 14.1 No. Rows 2 2 2 2 2 2 2 Outdoor Coil Fins per inch 20 20 20 20 20 20 20 Circuits 6 5 5 5 6 6 6 Face Area (sq. ft.) Sq. Ft. 4.4 4.4 4.4 4.4 4.4 4.4 4.4 No. Rows 4 4 4 4 4 4 4 Indoor Coil Fins per inch 19 19 19 19 19 19 19 Circuits 6 6 6 6 6 6 6 Type Scroll Scroll Scroll Scroll Scroll Scroll Scroll Compressor Model ZP24K5E-PFV-1 30 ZP29K5E-PFV-1 30 ZP29K5E-TF5-1 30 ZP29K5E-TFD-1 30 ZP42K5E-PFV-1 30 ZP42K5E-TF5-1 30 ZP42K5E-TFD-1 30 Outdoor Voltage, Phase, Cycle V/Ph/Hz 208/230-1-60 208/230-1-60 208/230-3-60 460-3-60 208/230-1-60 208/230-3-60 460-3-60 Indoor Voltage, Phase, Cycle V/Ph/Hz 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 Power Supply Indoor and outdoor units have dedicated power supply Electrical MCA (Outdoor) A. 17.2 19 12.8 7.6 28.8 18.6 8.6 MOCP - Fuse Rating (Outdoor) A. 30 30 20 15 50 30 15 MCA (Indoor) A. 3 3 3 3 3 3 3 MOCP - Fuse Rating (Indoor) A. 15 15 15 15 15 15 15 Unit Width In. 44.5 44.5 44.5 44.5 44.5 44.5 44.5 Unit Height In. 37.1 37.1 37.1 37.1 43.1 43.1 43.1 Outdoor Unit Depth In. 17.1 17.1 17.1 17.1 17.1 17.1 17.1 Net Weight Lbs. 196 197 197 197 246 246 246 Airflow CFM 2,615 2,615 2,615 2,615 2,785 2,785 2,785 Unit Width In. 65.0 65.0 65.0 65.0 65.0 65.0 65.0 Unit Height In. 9.3 9.3 9.3 9.3 9.3 9.3 9.3 Unit Depth In. 26.6 26.6 26.6 26.6 26.6 26.6 26.6 Net Weight Lbs. 98.8 98.8 98.8 98.8 98.8 98.8 98.8 Indoor No. of Fan Speeds 3 3 3 3 3 3 3 Airflow (lowest to highest) CFM 1310/1400/1470 1310/1400/1470 1310/1400/1470 1310/1400/1470 1310/1400/1470 1310/1400/1470 1310/1400/1470 Sound Pressure (lowest to highest) dB(A) 55/57/59 55/57/59 55/57/59 55/57/59 55/57/59 55/57/59 55/57/59 Air throw Data Ft. 29 29 29 29 29 29 29 * Liquid line needs to be insulated ** Refer to Ductless Split System Long Line Guide for additional information. Long Line accessories required beyond 80 ft (24.4 m). 10 COOLING PERFORMANCE DATA - COOLING ONLY UNITS Table 8 - Cooling Performance Data - Cooling Only Units EVAPORATOR AIR CONDENSER ENTERING AIR TEMPERATURES deg F 75 85 95 105 115 125 SIZE INDOOR UNIT OUTDOOR UNIT CFM EWB Capacity MBtuht Total System KW** Capacity MBtuht Total System Ksw- Capacity MBtuht Total System Ksw- Capacity MBtuht Total System KVV- Capacity MBtuht Total System KW- Capacity MBtuht Total System KW- Total Sens$ Total Sens$ Total Sens$ Total Sens$ Total Sens$ Total Sens$ 405 72 18.58 9.28 1.08 17.83 8.97 1.20 17.04 8.65 1.34 16.18 8.30 1.49 15.25 7.93 1.67 14.23 7.53 1.88 67 16.85 10.96 1.07 16.16 10.65 1.20 15.44 10.32 1.33 14.67 9.98 1.49 13.83 9.61 1.67 12.90 9.21 1.88 63 15.60 10.59 1.07 14.96 10.27 1.20 14.29 9.95 1.33 13.57 9.61 1.49 12.80 9.24 1.67 11.95 8.85 1.88 62 15.28 12.61 1.07 14.65 12.29 1.19 13.99 11.97 1.33 13.29 11.63 1.49 12.53 11.26 1.67 11.71 10.87 1.88 57 14.07 14.07 1.07 13.61 13.61 1.19 13.12 13.12 1.33 12.59 12.59 1.49 12.01 12.01 1.67 11.38 11.38 1.88 18 40MKCB18F--3 24AHA418AO03 124ANS018000 515 72 19.69 10.20 1.10 18.85 9.87 1.22 17.95 9.53 1.36 16.99 9.16 1.52 15.95 8.77 1.70 14.82 8.34 1.90 67 17.87 12.35 1.10 17.10 12.02 1.22 16.29 11.67 1.36 15.42 11.30 1.52 14.48 10.91 1.70 13.45 10.49 1.90 63 16.56 11.90 1.10 15.84 11.56 1.22 15.09 11.22 1.36 14.28 10.85 1.52 13.42 10.47 1.70 12.47 10.05 1.90 62 16.23 14.47 1.10 15.52 14.13 1.22 14.79 13.77 1.36 14.01 13.39 1.52 13.19 12.96 1.70 12.36 12.36 1.90 57 15.49 15.49 1.10 14.94 14.94 1.22 14.37 14.37 1.36 13.76 13.76 1.51 13.09 13.09 1.69 12.34 12.34 1.90 695 72 20.80 11.56 1.14 19.84 11.21 1.27 18.83 10.84 1.40 17.76 10.45 1.56 16.60 10.03 1.74 15.35 9.59 1.94 67 18.89 14.47 1.14 18.02 14.12 1.26 17.10 13.75 1.40 16.12 13.35 1.56 15.08 12.93 1.74 13.95 12.46 1.94 63 17.52 13.87 1.14 16.71 13.52 1.26 15.86 13.14 1.40 14.96 12.75 1.56 13.99 12.33 1.74 12.95 11.87 1.94 62 17.28 17.13 1.14 16.57 16.57 1.26 15.88 15.88 1.40 15.15 15.15 1.56 14.35 14.35 1.74 13.46 13.46 1.94 57 17.19 17.19 1.14 16.55 16.55 1.26 15.86 15.86 1.40 15.13 15.13 1.56 14.33 14.33 1.74 13.45 13.45 1.94 975 72 28.43 16.34 1.54 27.06 15.84 1.70 25.60 15.32 1.88 24.05 14.76 2.09 22.39 14.18 2.32 20.63 13.56 2.59 67 25.90 20.75 1.53 24.64 20.24 1.69 23.33 19.71 1.87 21.92 19.14 2.08 20.42 18.52 2.31 18.84 17.84 2.58 63 24.10 19.88 1.52 22.93 19.37 1.68 21.71 18.84 1.87 20.42 18.27 2.07 19.04 17.65 2.31 17.58 16.96 2.58 62 24.08 24.08 1.52 23.13 23.13 1.69 22.11 22.11 1.87 21.02 21.02 2.07 19.83 19.83 2.31 18.53 18.53 2.58 57 24.05 24.05 1.52 23.10 23.10 1.69 22.09 22.09 1.87 21.00 21.00 2.07 19.81 19.81 2.31 18.51 18.51 2.58 24 40MKCB34F--3 24AHA424AO03 124ANS024000 1130 72 28.86 17.43 1.58 27.43 16.92 1.74 25.92 16.38 1.92 24.31 15.82 2.13 22.59 15.22 2.36 20.77 14.58 2.63 67 26.31 22.48 1.57 25.01 21.95 1.73 23.65 21.38 1.91 22.20 2077. 2.12 2068. 2007. 2.35 19.11 19.11 2.62 63 24.50 21.48 1.57 23.29 20.95 1.73 2203. 2038. 1.91 20.71 1976. 2.11 19.31 1904. 2.35 17.92 17.92 2.62 62 25.08 25.08 1.57 24.05 24.05 1.73 22.96 22.96 1.91 21.77 21.77 2.12 2049. 2049. 2.35 1909. 1909. 2.62 57 25.05 25.05 1.57 24.02 24.02 1.73 22.93 22.93 1.91 21.75 21.75 2.12 20.47 20.47 2.35 19.08 19.08 2.62 1335 72 29.24 18.81 1.63 27.75 18.29 1.79 26.18 17.74 1.98 24.51 17.16 2.18 22.73 16.55 2.41 20.85 15.91 2.68 67 26.72 24.65 1.62 25.39 24.07 1.79 24.00 23.41 1.97 22.57 22.57 2.17 21.18 21.18 2.41 1968. 1968. 2.68 63 24.91 23.47 1.62 23.68 22.87 1.78 22.40 22.18 1.96 21.14 21.14 2.17 19.83 19.83 2.40 18.42 18.42 2.67 62 26.12 26.12 1.62 25.01 25.01 1.78 23.82 23.82 1.97 22.54 22.54 2.17 21.16 21.16 2.41 1966. 1966. 2.67 57 26.10 26.10 1.62 24.99 24.99 1.78 23.80 23.80 1.97 22.52 22.52 2.17 21.14 21.14 2.41 19.64 19.64 2.67 975 72 33.46 17.95 1.84 31.93 17.37 2.04 30.31 16.77 2.27 28.57 16.12 2.52 26.67 15.42 2.80 24.60 14.67 3.11 67 30.40 22.13 1.82 29.01 21.55 2.02 27.54 20.95 2.24 25.96 20.30 2.49 24.22 19.60 2.78 22.32 18.83 3.10 63 28.18 21.26 1.80 26.90 20.69 2.00 25.55 20.09 2.22 24.07 19.44 2.47 22.46 18.74 2.76 20.69 17.97 3.09 62 27.64 26.15 1.79 26.42 25.52 1.99 25.14 24.81 2.22 23.84 23.84 2.47 22.54 22.54 2.76 21.10 21.10 3.09 57 27.00 27.00 1.79 26.02 26.02 1.99 24.97 24.97 2.22 23.81 23.81 2.47 22.52 22.52 2.76 21.08 21.08 3.09 30 40MKCB34F--3 24AHA43OA003 124ANS030000 1130 72 34.21 19.05 1.89 32.60 18.46 2.09 30.89 17.83 2.31 29.07 17.17 2.56 27.08 16.46 2.84 24.92 15.69 3.16 67 31.09 23.87 1.86 29.63 23.28 2.06 28.08 22.65 2.29 26.42 21.98 2.54 24.61 21.25 2.82 22.65 20.44 3.14 63 28.85 22.88 1.84 27.49 22.29 2.04 26.06 21.67 2.27 24.53 21.00 2.52 22.84 2027. 2.80 21.02 1945. 3.13 62 28.42 28.42 1.84 27.32 27.32 2.04 26.16 26.16 2.27 24.90 24.90 2.52 23.50 23.50 2.81 21.95 21.95 3.14 57 28.35 28.35 1.84 27.29 27.29 2.04 26.13 26.13 2.27 24.87 24.87 2.52 23.48 23.48 2.81 21.92 21.92 3.14 1335 72 34.92 20.44 1.95 33.22 19.83 2.15 31.43 19.19 2.37 29.51 18.51 2.62 27.44 17.78 2.90 25.20 17.00 3.21 67 31.75 26.10 1.92 30.21 25.48 2.12 28.60 24.82 2.34 26.87 24.11 2.59 25.00 23.32 2.88 23.01 22.41 3.20 63 29.48 24.95 1.90 28.06 24.33 2.10 26.57 23.67 2.32 24.97 22.96 2.57 23.25 22.15 2.86 21.40 21.19 3.18 62 29.85 29.85 1.91 28.67 28.67 2.11 27.41 27.41 2.33 26.03 26.03 2.59 24.50 24.50 2.87 22.82 22.82 3.19 57 29.82 29.82 1.91 28.64 28.64 2.11 27.38 27.38 2.33 26.00 26.00 2.59 24.48 24.48 2.87 22.80 22.80 3.19 COOLING PERFORMANCE DATA - COOLING ONLY UNITS (CONT) EVAPORATOR AIR CONDENSER ENTERING AIR TEMPERATURES deg F 75 85 95 105 115 125 SIZE INDOOR UNIT OUTDOOR UNIT CFM EWB Capacity MBtuht Total System Kw- Capacity MBtuht Total System KW- Capacity MBtuht Total System KW** Capacity MBtuht Total System KW- Capacity MBtuht Total System KW** Capacity MBtuht Total System Kyy** Total Sens$ Total Sens$ Total Sens$ Total Sens$ Total Sens$ Total Sens$ 975 72 38.57 20.08 2.15 36.82 19.40 2.38 34.94 18.67 2.64 32.90 17.90 2.93 30.68 17.07 3.25 28.28 16.18 3.62 67 35.06 24.40 2.13 33.47 23.71 2.36 31.77 22.99 2.62 29.92 22.22 2.90 27.91 21.39 3.23 25.73 2050. 3.61 63 32.51 23.50 2.11 31.05 22.82 2.34 29.47 22.10 2.60 27.76 21.34 2.89 25.91 20.51 3.22 23.89 1963. 3.60 62 31.86 28.62 2.11 30.43 27.92 2.34 28.90 27.16 2.60 27.26 26.33 2.88 25.47 25.47 3.21 23.82 23.82 3.59 57 30.45 30.45 2.10 29.35 29.35 2.34 28.16 28.16 2.59 26.85 26.85 2.88 25.40 25.40 3.21 23.79 23.79 3.59 34 40MKCB34F--3 24AHA436AOOx 124AxS036000 1130 72 39.58 21.26 2.20 37.72 20.56 2.43 35.73 19.81 2.69 33.58 19.01 2.97 31.23 18.16 3.30 28.73 17.25 3.67 67 36.01 26.24 2.17 34.31 25.54 2.41 32.51 24.79 2.66 30.56 24.00 2.95 28.43 23.14 3.28 26.16 22.22 3.65 63 33.41 25.22 2.16 31.85 24.52 2.39 30.18 23.78 2.64 28.37 22.99 2.93 26.41 22.14 3.26 24.30 21.22 3.64 62 32.81 31.05 2.16 31.32 30.28 2.39 29.74 29.40 2.64 28.18 28.18 2.93 26.59 26.59 3.26 24.85 24.85 3.64 57 32.09 32.09 2.15 30.88 30.88 2.38 29.57 29.57 2.64 28.14 28.14 2.93 26.56 26.56 3.26 24.82 24.82 3.64 1335 72 40.56 22.74 2.26 38.58 22.01 2.49 36.47 21.24 2.75 34.21 20.43 3.03 31.74 19.54 3.36 29.12 18.62 3.73 67 36.91 28.59 2.23 35.12 27.86 2.47 33.20 27.09 2.72 31.15 26.26 3.01 28.93 25.36 3.33 26.57 24.38 3.71 63 34.28 27.41 2.22 32.61 26.68 2.45 30.84 25.91 2.70 28.95 25.09 2.99 26.90 24.19 3.32 24.73 23.20 3.69 62 33.93 33.93 2.21 32.58 32.58 2.45 31.14 31.14 2.71 29.56 29.56 3.00 27.82 27.82 3.33 25.92 25.92 3.70 57 33.88 33.88 2.21 32.54 32.54 2.45 31.10 31.10 2.71 29.53 29.53 3.00 27.79 27.79 3.33 25.89 25.89 3.70 1310 72 62.74 32.88 3.71 60.01 31.83 4.08 57.07 30.70 4.52 53.87 29.50 5.02 50.33 28.19 5.59 46.46 26.77 6.24 67 57.20 40.15 3.66 54.76 39.11 4.04 52.10 38.00 4.47 49.19 36.79 4.97 45.97 35.47 5.54 42.43 34.04 6.20 63 53.18 38.72 3.63 50.93 37.69 4.00 48.49 36.59 4.43 45.81 35.39 4.93 42.83 34.08 5.50 39.56 32.66 6.16 62 52.18 47.28 3.62 49.99 46.22 4.00 47.64 45.08 4.43 45.06 43.80 4.92 42.28 42.28 5.50 39.62 39.62 6.16 57 50.23 50.23 3.61 48.53 48.53 3.98 46.65 46.65 4.42 44.56 44.56 4.92 42.21 42.21 5.50 39.56 39.56 6.16 54 40MKCB54F--3 24AHA448AOOx 124AxSO48000 1400 72 63.45 33.74 3.74 60.65 32.67 4.12 57.65 31.54 4.55 54.35 30.32 5.05 50.73 28.99 5.62 46.78 27.56 6.28 67 57.89 41.51 3.70 55.36 40.45 4.07 52.63 39.32 4.50 49.65 38.10 5.00 46.35 36.76 5.58 42.75 35.31 6.23 63 53.84 39.99 3.66 51.51 38.94 4.04 49.01 37.82 4.47 46.25 36.61 4.96 43.21 35.28 5.54 39.88 33.83 6.19 62 52.87 49.09 3.66 50.64 48.00 4.03 48.23 46.80 4.46 45.66 45.40 4.96 43.11 43.11 5.54 40.36 40.36 6.20 57 51.43 51.43 3.65 49.64 49.64 4.02 47.68 47.68 4.46 45.51 45.51 4.96 43.05 43.05 5.54 40.31 40.31 6.20 1470 72 63.94 34.39 3.77 61.10 33.32 4.14 58.03 32.18 4.58 54.68 30.94 5.08 51.01 29.61 5.65 47.00 28.17 6.30 67 58.35 42.55 3.72 55.77 41.48 4.10 53.00 40.34 4.53 49.96 39.10 5.03 46.61 37.75 5.60 42.97 36.29 6.25 63 54.28 40.96 3.69 51.92 39.90 4.06 49.36 38.77 4.49 46.56 37.54 4.99 43.48 36.20 5.56 40.09 34.74 6.21 62 53.38 50.47 3.68 51.11 49.34 4.06 48.70 48.07 4.49 46.24 46.24 4.99 43.72 43.72 5.57 40.89 40.89 6.23 57 52.28 52.28 3.67 50.45 50.45 4.05 48.42 48.42 4.49 46.18 46.18 4.99 43.66 43.66 5.57 40.84 40.84 6.23 t Total and sensible capacities are net capacities. Blower motor heat has been subtracted. t Sensible capacities shown are based on 80° F (27° C) entering air at the indoor coil. For sensible capacities at other than 80* F (27* C), deduct 835 Btuh (245 kW) per 1000 CFM (480 L/S) of indoor coil air for each degree below 80° F (27° C), or add 835 Btuh (245 kW) per 1000 CFM (480 US) of indoor coil air per degree above 80' F (27' C). ** System kw is total of indoor and outdoor unit kilowatts. EWB - Entering Wet Bulb NOTES: 1. Detailed cooling capacities are based on indoor and outdoor unit at the same elevation per AHRI standard 210/240-2008. If additional tubing length and/or indoor unit is located above outdoor unit, a slight variation in capacity may occur. 2. When the required data falls between the published data, interpolation may be performed. Extrapolation is not an acceptable practice. COOLING PERFORMANCE DATA - HEAT PUMP UNITS Table 9 - Cooling Performance Data - Heat Pump Units • •7 • • K•].L1:1 61 :1 A :1 11:1VI lr1e1IA141,,1:j:I 111:7�Y.t�_7 Erg MOM-11"M ��6-7' I■�af3'�i �• ����a' 'i��:�.�a�a�a�'■�'��:�c■�:�a�a •t t • �a� .��. ���', t • •t ��� t •' • • • • cam., ��c �. G ��fi�fi��,, �I� `�%a `�%a�■ `�I' I■ `�I' I■�'a `�I■ `�I■ t • t • • t • � �a�a�aia�ia��r�■�r�■r�■ �a�a�a�a�■�■�_ � '•�asa�_�ar�sa�_rsf.�rs�a�'ar�a ' • • ��iS■ �.��a�� t '• �a� • 'c �r�ars���r�'��■rsi���•�r�ar���■�as'a t Total and sensible capacities are net capacities. Blower motor heat has been subtracted. t Sensible capacities shown are based on 80° F (27° C) entering air at the indoor coil. For sensible capacities at other than 80° F (27° C), deduct 835 Btuh (245 kW) per 1000 CFM (480 L/S) of indoor coil air for each degree below 80° F (27° C), or add 835 Btuh (245 kW) per 1000 CFM (480 US) of indoor coil air per degree above 80° F (27° C). ** System kw is total of indoor and outdoor unit kilowatts. EWB — Entering Wet Bulb NOTES: 1. Detailed cooling capacities are based on indoor and outdoor unit at the same elevation per AHRI standard 210/240-2008. If additional tubing length and/or indoor unit is located above outdoor unit, a slight variation in capacity may occur. 2. When the required data falls between the published data, interpolation may be performed. Extrapolation is not an acceptable practice. HEATING PERFORMANCE DATA - HEAT PUMP UNITS Table 10 - Heating Performance Data - Heat Pump Units INDOOR AIR OUTDOOR COIL ENTERING AIR TEMPERATURES deg F 17 27 37 47 57 67 SIZE INDOOR UNIT OUTDOOR UNIT EDB CFM Capacity MBtuh Total System KWt Capacity MBtuh Total System KWt Capacity MBtuh Total System KWt Capacity MBtuh Total System KWt Capacity MBtuh Total System KWt Capacity MBtuh Total System KWt Total Integ* Total Integ* Total Integ* Total Integ* Total Integ* Total Integ* 65 1310 16.42 14.97 1.82 20.90 18.56 1.89 24.80 22.57 1.94 29.15 29.15 1.98 34.27 34.27 2.04 40.12 40.12 2.11 1400 16.57 15.11 1.84 21.04 18.69 1.90 24.97 22.72 1.94 29.34 29.34 1.99 34.51 34.51 2.04 40.41 40.41 2.10 1470 16.67 15.20 1.85 21.15 18.78 1.91 25.08 22.82 1.95 29.49 29.49 1.99 34.69 34.69 2.04 40.61 40.61 2.10 30 40MKQB36F--3 22 24ANS030000 003 4ANS030 70 1310 15.91 14.51 1.90 19.96 17.73 1.96 24.39 22.19 2.02 28.68 28.68 2.07 33.66 33.66 2.12 39.41 39.41 2.19 1400 16.05 14.64 1.91 20.16 17.91 1.97 24.55 22.34 2.02 28.87 28.87 2.07 33.90 33.90 2.12 39.69 39.69 2.19 1470 16.16 14.73 1.92 20.31 18.04 1.98 24.66 22.44 2.03 29.00 29.00 2.07 34.07 34.07 2.12 39.90 39.90 2.19 75 1310 15.37 14.02 1.98 19.36 17.19 2.04 24.00 21.84 2.10 28.21 28.21 2.16 33.07 33.07 2.21 38.71 38.71 2.28 1400 15.51 14.14 1.99 1952. 17.34 2.05 24.15 21.97 2.11 28.39 28.39 2.16 33.31 33.31 2.21 38.99 38.99 2.28 1470 15.62 14.24 2.00 19.65 17.45 2.05 24.25 22.06 2.11 28.53 28.53 2.16 33.47 33.47 2.21 39.19 39.19 2.28 65 1310 19.33 17.63 2.15 23.84 21.17 2.21 29.39 26.74 2.29 34.35 34.35 2.36 40.13 40.13 2.45 46.81 46.81 2.57 1400 19.51 17.79 2.15 24.04 21.35 2.21 29.58 26.92 2.29 34.60 34.60 2.35 40.44 40.44 2.44 47.23 47.23 2.55 1470 19.64 17.91 2.16 24.19 21.48 2.22 29.74 27.06 2.29 34.77 34.77 2.35 40.67 40.67 2.43 47.52 47.52 2.54 36 40MKQB36F--3 224AxS036000 224AxSO36000 70 1310 18.69 17.04 2.24 23.16 20.57 2.30 28.88 26.28 2.40 33.79 33.79 2.47 39.42 39.42 2.56 45.98 45.98 2.68 1400 18.87 17.20 2.25 23.36 2075. 2.31 29.08 26.46 2.39 34.03 34.03 2.46 39.73 39.73 2.54 46.38 46.38 2.66 1470 19.00 17.32 2.25 23.51 20.88 2.31 29.23 26.60 2.39 34.20 34.20 2.46 39.95 39.95 2.54 46.67 46.67 2.64 75 1310 17.99 16.41 2.33 22.46 19.95 2.40 27.59 25.11 2.49 33.22 33.22 2.58 38.72 38.72 2.67 45.15 45.15 2.80 1400 18.17 16.57 2.34 22.67 20.13 2.41 27.91 25.39 2.49 33.44 33.44 2.57 39.03 39.03 2.66 45.55 45.55 2.78 1470 18.30 16.69 2.35 22.82 20.27 2.41 28.16 25.63 2.49 33.61 33.61 2.57 39.25 39.25 2.65 45.82 45.82 2.76 65 1310 26.47 24.13 3.02 32.32 28.70 3.15 39.75 36.17 3.33 46.52 46.52 3.49 53.91 53.91 3.67 62.41 62.41 3.90 1400 26.71 24.36 3.02 32.62 28.97 3.14 40.40 36.77 3.31 46.88 46.88 3.45 54.39 54.39 3.62 63.03 63.03 3.83 1470 26.89 24.51 3.02 32.83 29.16 3.13 40.63 36.97 3.30 47.13 47.13 3.43 54.73 54.73 3.59 63.48 63.48 3.79 48 40MKQB48F--3 224AxSO48000 224AxSO48000 70 1310 25.69 23.42 3.13 31.47 27.95 3.27 38.21 34.77 3.44 45.83 45.83 3.64 53.06 53.06 3.83 61.41 61.41 4.07 1400 25.93 23.64 3.13 31.77 28.22 3.26 38.71 35.22 3.42 46.17 46.17 3.60 53.52 53.52 3.78 62.01 62.01 4.00 1470 26.11 23.80 3.13 31.99 28.41 3.26 39.08 35.57 3.41 46.40 46.40 3.58 53.85 53.85 3.75 62.44 62.44 3.95 75 1310 24.85 22.66 3.26 30.61 27.18 3.41 37.15 33.80 3.58 45.14 45.14 3.80 52.24 52.24 4.00 60.43 60.43 4.24 1400 25.10 22.88 3.26 30.90 27.45 3.39 37.53 34.15 3.55 45.44 45.44 3.76 52.68 52.68 3.94 61.01 61.01 4.18 1470 25.29 23.06 3.26 31.11 27.63 3.39 37.81 34.41 3.54 45.69 45.69 3.74 53.00 53.00 3.91 61.43 61.43 4.13 "* The Btuh heating capacity values shown are net integrated values from which the defrost effect has been subtracted. The Btuh heating from supplement heaters should be added to those values to obtain total system capacity. t The kW values include the compressor, outdoor fan motor, and indoor blower motor. The kW from supplement heaters should be added to these values to obtain total system kilowatts. NOTE: When the required data falls between the published data, interpolation may be performed. Extrapolation is not an acceptable practice. EDB - Entering Dry Bulb" APPLICATION DATA UNIT SELECTION Table 12—Heating Operating Range The horizontal units are available as cooling only and heat pumps. For most applications, the cooling load dictates the size selection. Select equipment to either match or be slightly less than anticipated peak load. This provides better humidity control, fewer unit cycles, and better low load performance. For units used in spaces with high sensible loads, base equipment selection on unit sensible load, not on total anticipated load to avoid oversizing the equipment. UNIT MOUNTING (INDOOR) Unit leveling - For reliable operation, units should be level in all planes. Clearance - Provide adequate clearance for airflow (see Fig. 7). Unit location - Select a location which will provide the best air circulation for the room. The Under Ceiling units should be mounted near the ceiling and against a wall. The unit should be centered in the room for best performance. Locating the unit on an outside wall makes piping easier, however units can also be mounted away from a wall if desired. If unit is mounted away from a wall, the rear panel of the unit may need a field -supplied trim strip for improved appearance. Locate the fan coil return over an area which is not normally occupied for quietest operation. Do not block air discharge for a minimum of 15 ft (4.6 m) to prevent dumping of cold air and drafts. Support - The structure must provide adequate support for the weight of the fan coil. Refer to the Physical Data section for fan coil weights. Mounting Template - The fan coil units are furnished with cardboard mounting templates to mark the hole locations for wiring and refrigerant lines. UNIT MOUNTING (OUTDOOR) Unit leveling - For reliable operation, units should be level in all planes. Clearance - Minimum clearance, as shown in Fig. 10, must be provided for airflow. The condensing units are designed for free -blow application. Air inlets and outlets should not be restricted. Unit location - A location which is convenient to installation and not exposed to strong wind. If the unit is exposed to strong winds it is recommended that a wind baffle accessory be used. A location which can bear the weight of outdoor unit and where the outdoor unit can be mounted in a level position. SYSTEMS OPERATING CONDITIONS Table 11—Cooling Operating Range Maximum Minimum DB °F (oQ WB °F (oQ DB °F (oQ WB °F (oQ Outdoor Unit 125 (51.7) -- 55 (12.8) -- Indoor Unit 90 (32.2) 84 (29) 64 (18) 59 (29) Maximum Minimum DB °F (oQ WB °F (oQ DB °F (oQ WB °F (oQ Outdoor Unit 75 (23.9) 67 (19.4) 17 (-8.3) -- Indoor Unit 80(27) -- 32(0) -- Low Ambient Operation Both the cooling only and heat pumps operate to cool down to 55°F (12.8°C). When equipped with a Low Ambient Controller, the unit operates down to -20°F (-28.9°C). For proper operation of colling only units, a Winter Start Kit), a Crankcase Heater (prevents refrigerant migration during compressor -off cycle), and a Wind Baffle should also be installed. On heat pumps, a Winter Start Kit will not be required. An Isolation Relay, to bypass the Low Ambient Controller when unit is in heating mode, is required. Metering Devices The metering device(s) for these systems is a type B accurator. The cooling accurator is installed with the indoor unit, while the heating accurator is installed with the outdoor unit. One Accurator is required for the cooling only system and two are required for the heat pump systems. Refer to Table 13 for the accurator size. Table 13—Metering Device System Size kBTU/hr Cooling Only Heat Pumps 40MKCB**C 40MKQB**C 25HHA4/224ANS 018 TXV 024 TXV - 030 TXV TXV 0.055' 034 TXV - 054 TXV - 036 - TXV 0.063" 048 TXV 0.073" DRAIN CONNECTIONS When the unit is installed close to an outside wall, a downward sloped condensate line can be used to dispose of the water (do not trap condensate line). If this is not feasible, an accessory condensate pump that can be installed inside the unit is available. When using a condensate pump, the drain pipe can be routed through the top of the unit, if desired. Install drains to meet local sanitation codes. If adequate gravity drainage cannot be provided, unit should be equipped with accessory condensate pump. 15 CONTROL SYSTEM REFRIGERANT LINES General refrifferant line sizing 1. Refrigerant lines can access the Under Ceiling unit from either the top -right or rear -right when facing the unit. 2. Refrigerant lines should not be buried in the ground. If it is necessary to bury the lines, not more than 36-in (914 mm) should be buried. Provide a minimum 6-in (152 mm) vertical rise to the service valves to prevent refrigerant migration. 3. Both lines must be insulated. Use a minimum of 1/2-in. (12.7mm) thick insulation. Closed -cell insulation is recommended in all long -line applications. 4. Special consideration should be given to isolating interconnecting tubing from the building structure. Isolate the tubing so that vibration or noise is not transmitted into the structure. NOTE: Since the same outdoor unit can be matched with different types of indoor units, it may not have enough refrigerant charge. Refer to the Physical Data tables to determine if additional charge is required. Long Line Applications The minimum length between the indoor and outdoor units is 10 ft. (3m). Refer to the following table for the maximum lengths allowed. Table 14—Long Line Applications Outdoor Unit Size Max Equivalent Length* ft (m) Max Elevation (ID over OD) ft (m) Max Elevation (OD over ID ft (m) 18-54K 250 (76.2) 65 (19.8) 200 (61) NOTE: For lengths greater than 25 ft (7.6 m), refer to the Residential Long Line guide. * Maximum actual length not to exceed 200 ft (61 m) Total equivalent length accounts for losses due to elbows or fitting. See the Long Line Guideline for details. The ductless unit is equipped with a microprocessor controls to operate the system and provide optimum levels of comfort and operating efficiency. The main microprocessor is located in the control box of the fan coil unit with thermistors located in the fan coil inlet and on the indoor coil. These thermistors monitor the system operation and control the operating mode. To change the settings or the modes of operation, use the factory supplied wireless remote control or accessory wired controller. The ductless unit has 5 operating modes: • Fan Only • Auto (heat pump models only) • Heating (heat pump models only) • Cooling • Dehumidification (Dry) FAN ONLY - In the Fan Only mode, the system filters and circulates the room air without changing the room air temperature. AUTO - In Auto mode, the system will automatically select one of the following operating modes: cooling, heating or fan only based on the difference between the room temperature and the set point temperature. HEATING - In the Heating mode, the system heats and filters room air. COOLING - In the Cooling mode, the system cools, dries and filters room air. DEHUMIDIFICATION (DRY) - in Dehumidification (Dry) mode, the system dries, filters and slightly cools room temperature. This mode does not take the place of a dehumidifier. In addition to the above modes that are selected by using the remote control. The unit can run in two other modes selected by the manual button: • EMERGENCY RUN • TEST MODE EMERGENCY mode - is used when the remote control is misplaced or the batteries in the remote control have expired. Pushing the manual button under the front cover will put the unit in Auto mode with a predetermined set point (73.4°F/ 23°C). TEST mode - is used when a technician needs to diagnose the unit for a malfunction. The unit can be set into TEST mode using the remote control. It will run regardless of the set point. The microprocessor controls offer additional comfort and economy features like SLEEP mode, TIMER and AUTO SWEEP. Refer to the Owner's Manual for additional details on these features. USER INTERFACE The units come standard with a wireless remote control. The wireless remote has a range of 25 ft (8 m) when pointed toward the unit. For some applications (commercial), a wired remote may be more desirable. A wired remote control is offered as an accessory. Table 15—Air Throw Data Air Throw Data ft (m) 18 (AC) 26(7.9) 24-54 (AC) 29 (8.8) 30-48 (HP) 16 SOUND RATINGS Outdoor Units Table 16-A-WEIGHTED SOUND POWER (dBA) Outdoor Unit Size Standard Typical Octave Band Spectrum (dBA, without tone adjustment) Rating (dBA) 125 250 500 1000 2000 4000 8000 18 69 50.5 57.0 59.5 64.5 60.5 53.5 43.0 Cooling Only 24 66 50.5 58.5 60.5 59.5 56.5 51.0 41.5 30 68 55.5 59.5 61.5 63.5 60.0 58.0 49.5 36 71 59.5 59.5 62.0 65.5 63.5 62.0 55.0 30 72 58.0 61.0 64.0 66.5 64.0 63.5 57.0 Heat Pump 36 71 59.5 59.5 62.5 65.0 63.0 61.5 55.0 48 70 1 57.5 1 59.5 1 63.0 65.0 62.5 60.0 54.0 NOTE: Tested in accordance with AHRI Standard 270-08 (not listed in AHRI). Table 17-Indoor Units ESTIMATED UNDER CEILING SOUND PRESSURE LEVEL Under -ceiling AC:18 AC: 24-34 AC:54 HP: 30 - 48 Cooling operation Indoor Sound Pressure for CO and HP cooling mode (at Different Speeds) dBa (cfm) 53/48/42 (695/515/405) 55/52/50 (1335/1130/975) 59/57/55 (1470/1400/1310) Heating operation Indoor Sound Pressure for HP heating mode (at Different Speeds) dBa (cfm) NA NA 58/55/54 (1470/1400/1310) ESTIMATED UNDER CEILING SOUND POWER LEVEL Under -ceiling AC:18 AC: 24-34 AC:54 HP: 30 - 48 Cooling operation Indoor Sound Pressure for CO and HP cooling mode (at Different Speeds) dBa (cfm) 63/58/52(695/515/405) 65/62/60(1335/1130/975) 69/67/65 (1470/1400/1310) Heating operation Indoor Sound Pressure for HP heating mode (at Different Speeds) dBa (cfm) NA NA 68/65/64 (1470/1400/1310) NOTES: 1. Sound power ratings are tested in accordance with AHRI standard 270---95 (not listed in AHRI) and AHRI 350. 2. Sound pressure ratings are estimated sound pressure, 3 feet (.91 m) from the unit, based on sound power data. 17 WIRING The indoor and outdoor units have their own power supply. Refer to installation instructions for Wiring instructions. ELECTRICAL DATA Table 18-24AHA4/124ANS Electrical Data UNIT SIZE -- voltage,series V/PH OPER VOLTS* COMPR FAN MCA MAX FUSE** or CKT BRK AMPS MAX MIN LRA RLA FLA 18--30 208/230/1 253 197 56.3 9 0.5 11.8 20 24--30 62.9 10.9 0.5 14.1 25 30--30 73 14.1 0.7 18.3 30 36--30 77 14.1 1.2 18.8 30 48--30 124 18.5 1.2 24.3 40 36--50 208/230/3 253 197 71 9 1.2 12.5 20 48--50 83.1 13.7 1.2 18.3 30 36--60 460/3 506 414 38 5.6 0.6 7.6 15 48--60 41 6.2 0.6 8.4 15 Table 19-25HHA4/224ANS Electrical Data MAX FUSE** UNIT SIZE -- OPER VOLTS* COMPR FAN V/PH MCA or CKT BRK voltage,series MAX MIN LRA RLA FLA AMPS 30--30 208/230/1 253 197 64 12.8 1.2 17.2 30 36--30 77 14.2 1.2 19 30 48--30 117 21.8 1.45 28.8 50 36--50 208/230/3 253 197 71 9.3 1.2 12.8 20 48--50 83.1 13.7 1.45 18.6 30 36--60 460/3 506 414 38 5.6 0.6 7.6 15 48--60 41 6.2 0.8 8.6 15 Table 20-40MKCB**F Electrical Data Indoor Unit Size BTU/Hr V-Ph-Hz Voltage Range Fan Power Min (V) Max (V) FLA (A) Min Ckt Amp (A) Max Fuse) Amp (A) 18K 208-230-1-60 187 253 0.71 1 15 24K - 34K 208-230-1-60 187 253 0.7 x 2 3 15 54K 208-230-1-60 187 253 0.95 x 2 3 15 Table 21-40MKQB**F Electrical Data Indoor Unit Size BTU/Hr V-Ph-Hz Voltage Range Fan Power Min (V) Max (V) FLA (A) Min Ckt Amp Max Fuse CB (A) Amp (A) 30K- 48K 208-230-1-60 187 253 0.95 x2 3 15 LEGEND FLA -Full Load Amps HACR- Heating, Air Conditioning, Refrigeration LRA- Locked Rotor Amps NEC- National Electrical Code RLA- Rated Load Amps (compressor) *Permissible limits of the voltage range at which the unit will operate satisfactorily **Time- Delay fuse. Complies with 2007 requirements of ASHRAE Standards 90.1 18 II I I DISPLAY BOARD TO WIRED REMOTE CONTROLLER CONNECTOR Legend: —I ........Model specific feature L GMl I GM3 I XPI CAP: C apacitor T ! xS1 CN 1: Live wire Ll/Null line L2 CN 213: Transformer interface CN 25:Controls 24V signal interface(C) L CNTSensor interface i CN 20: Network module interface CN72 I CN10 I CN15 I CN11 CN 12: Vertical swing motor Interface (WHITE) (RED) I CN 13: horizontal swing motor interface — --I L—_ —� C N 10. D isplay board interface MAIN CONTROL BOARD CN15:Compressor signal interface CN 11: Water level detection switch CN7 CN 16: Motor interface XP2 RT1: Room temperature sensor xS2 ON25 CN3 crvz cN1 CN16 RT2: PICE temperature s ensor T3/4:Transformer XP4 T4 G M1 /3: L evel s wing motor GM2:Vertical swingmotor XS/XP: Connectors RT2 2 RTl T3 L I I FAN1 FAN2 —I I I WHITE WHITE IWHITE WHITE I Y�C �� CAP I L — _ CAP2_ — — — — — Notes: � I 24V— Controls 1.Tobewiredinaccordance with National I NET MODULE TO CCM $w1 0 signal to POWER Electric opper conductors odes. Mode outdoor unit SUPPLY 2.Use Copper conductors only. FLOOR CEILING Use conductors suitable for at least 75°C(167°F),I gN2. FACTORY 3. Ifany ofthe original wires, as supplied I J _ _ _ _ _ _ _ SETRNG must be replaced, use the same or equivalent wire. — Fig. 9 — 40MKCB**F wiring diagram OUTDOOR UNIT SCHEMATIC DIAGRAM I L1 L2 COMP 1 D C *LPS *DTS *HPS T1 T3 *CTD *LLS CONT Fig. 10 — 24AHA4/124ANS Wiring Diagram 208/230V 1 Phase 19 I I I I EQUIF GND j L1 L2 L3 COMP I 0 , CONT * HPS ' LIPS T2 LOGI T1 T3 Q * CTD r D IFR a--------------------------------- R C------------i INDOOR THERMOSTAT EXTERNAL POWER SUPPLY 24 V Fig. 11— 24ARA4/124ANS Wiring Diagram 208/230 - 460V 3 phase DISPLAY O BOARD GM2 V Xs11 2N12 2N13 I CN10 CN15 I CN71 i LCN20 (WHITE) (RED) MAIN CONTROL BOARD CNT CN25 CN3 CN2 CN7 CNl6 XP4 T4 ,34 RT2 RTI[fl I T3 XP3 �XS31 FAN1 CAP1 WIRED REMOTE CONTROLLER CONNECTOR Legen d: ................Model specific fe ature CAP: Capac itor CN1: Livewire Ll /Null lineL2 CN2/3:Transformer interface CN 25 Controls 24V signal interface(R /CI CN 7: Sens or interface CN 20 : Network module interface CN 12 :Vertical swing motor interface CN 13 : horizontal swing motor interface CN 10 : Disp lay board interface CN 15 :Sign al inte rface(Y/0) CN 1 l: Wa ter level detection switch CN 16:Motor interface RTI: Room temperature Sens or RT2: Pipet emperature sensor T3/4: Trans former GM1/3: Leve I swin g motor GM 2: Vert ical s wing motor XS/XP :Connectors I Y/G I I FAN2 I I I WHITE WHITE Xa _ I 0AP2 11 — J 24V-- I POWER Notes: r — 1 Controls SUPPLY 1.Tobewired inaccordancewith NationaI ON SW1 Q signal to TO CCM outdoor ElectricRE.C. a nd local cod es. � NET MoouLE MODE FLOOR CEILING unit Use nductoopper con itablefuctors ontl Use c onductors s uitable for at lea st 75° C(167 °F). I FACTORY 3. If a ny of the original wires, as s upplied I cN2o I SETTING must be re place d,use the s ame o r equ ivalen t wire. L — — — — — — — — — Fig. 12 — 40MKQB**F wiring diagram 20 I (OUTDOOR UNIT SCHEMATIC DIAGRAM 2 _ I I I CONT COMP R I — 11 21 C I I 5 2 *SC S *ST EQUIP +t GND 1 H *SR CONT * CHS DR OFM C T 23 23 *CH OF1 OF2 F CAP D\/C _ Fig. 13 — 25HHA4/224ANS Wiring Diagram 208/230V 1 Phase L1 L2 L3 I I I I I I CONT I r2COMP -------� I L — — 11 21 _ T1 T EQUIP GND DR OFM CAP CONT *CHS *CH OF1 OF2 3 13 RVS Fig. 14 — 25HHA4/224ANS Wiring Diagram 208/230V 3 phase 21 L1 I I CONT EQUIP GND *CHS o 0 0 *CH L2 I L3 T2 COMP — J ------ T I T1 OFM CAP OFR 3 LNTCO RVS Fig. 15 — 25HHA4/224ANS Wiring Diagram 460V 3 phase 22 GUIDE SPECIFICATIONS INDOOR UNDER CEILING DUCTLESS UNITS PART 1 - GENERAL 1.01 System Description Indoor, under ceiling, direct -expansion fan coils are matched with cooling only or heat pump outdoor unit. 1.02 Agency Listings Unit shall be rated per AHRI Standards 210/240 and listed in the AHRI directory as a matched system. 1.03 Delivery, Storage, And Handling Units shall be stored and handled per unit manufacturer's recommendations. 1.04 Warranty (For Inclusion By Specifying Engineer) PART 2 - PRODUCTS 2.01 Equipment A. General: Indoor, direct -expansion, under ceiling fan coil. Unit shall be complete with cooling/heating (heat pump systems only) coil, fan, fan motor, piping connectors, electrical controls, microprocessor control system, and integral temperature sensing. Unit shall be furnished with mounting bracket. B. Unit Cabinet: 1. Unit cabinet shall be zinc -coated bonderized steel finished with a baked enamel paint. 2. Inlet grilles shall be attractively styled, high impact polystyrene. 3. Matching mounting brackets shall be provided. C. Fans: 1. Indoor fans shall be 3-speed centrifugal blower type with air intake in the bottom rear of the unit and discharge in the front. 2. Automatic, motor -driven horizontal air sweep shall be provided standard. D. Coil: Coil shall be copper tube with aluminum fins and galvanized steel tube sheets. Fins shall be bonded to the tubes by mechanical expansion and specially coated for enhanced wettability. A drip pan under the coil shall have a drain connection for the hose attachment to remove condensate. E. Motors: Motors shall be open drip -proof, permanently lubricated ball bearing with inherent overload protection. Fan motors shall be 3-speed. F. Controls: Controls shall consist of a microprocessor -based control system which shall control space temperature, determine optimum fan speed, and run self diagnostics. the temperature control range shall be from 62°F to 86°F (17°C to 30°C) in increments of 1°F or VC, and have 46°F Heating Mode (Heating Setback). The wireless remote controller shall have the ability to act as the temperature sensing location for room comfort.. Model Number: 40MKCF/40MKQF Size Range: 1-1/2 to 4-1/2 Ton Nominal Cooling and Heating Capacity The unit shall have the following functions as a minimum: 1. An automatic restart after power failure at the same operating conditions as at failure. 2. A timer function to provide a minimum 24-hour timer cycle for system Auto Start/Stop. 3. Temperature -sensing controls shall sense return air temperature. 4. Indoor coil freeze protection. 5. Wireless infrared remote control to enter set points and operating conditions. 6. Automatic vertical air sweep control to provide on or off activation of air sweep louvers. 7. Dehumidification mode shall provide increased latent removal capability by modulating system operation and set point temperature. 8. Fan -only operation to provide room air circulation when no cooling is required. 9. Diagnostics shall provide continuous checks of unit operation and warn of possible malfunctions. Error messages shall be displayed at the unit. 10. Fan speed control shall be user -selectable: high, medium, low, or microprocessor controlled automatic operation during all operating modes. 11. Automatic heating -to -cooling changeover in heat pump mode. Control shall include deadband to prevent rapid mode cycling between heating and cooling. 12. Indoor coil high temperature protection shall be provided to detect excessive indoor discharge temperature when unit is in heat pump mode (Heat pump units only). G. Filters: Unit shall have filter track with factory -supplied cleanable filters. H. Electrical Requirements: Indoor units shall be 208/230-1-60 and require their own power supply. Only control wiring shall run between the indoor and outdoor units. I. Operating Characteristics: The 40MK*F when matched with the appropriate outdoor section, shall have a minimum listed SEER (seasonal energy efficiency ratio) of 14 at AHRI conditions, and a minimum HSPF of 8.2 (Heat pump units only). J. Refrigerant Lines: All units should have refrigerant lines that can be oriented to connect from the left, right or back of unit. Both refrigerant lines need to be insulated. K. Special Features (Field Installed): 1. Condensate Pump: - The condensate pump shall remove condensate from the drain pan when gravity drainage cannot be used. Pump shall be designed for quiet operation. Pump shall consist of two parts: an internal reservoir/sensor assembly, and a remote sound -shielded pump assembly. A liquid level sensor in the reservoir shall stop cooling operation if the liquid level in the reservoir is unacceptable. 2. Wired Control (Optional): - The wired control can replace the standard wireless control and provide the User Interface to control one unit. 23 GUIDE SPECIFICATIONS PART 1 - GENERAL 1.01 System Description A. Outdoor air-cooled split system compressor sections suitable for on -the -ground, rooftop, wall hung or balcony mounting. Units shall consist of a scroll compressor, an air-cooled coil, propeller -type blow -through outdoor fan, reversing valve (HP), accumulator, Accurator metering device(s), and control box. Units shall discharge air horizontally as shown on the contract drawings. Units shall function as the outdoor component of an air-to-air cooling only, or heat pump system. B. Units shall be used in a refrigeration circuit matched to ductless cooling only or heat pump fan coil units. 1.02 Agenc, Listings A. Unit construction shall comply with ANSI/ASHRAE 15, latest revision, and with the NEC. B. Units shall be evaluated in accordance with UL standard 1995. C. Units shall be listed in the CEC directory. D. Unit cabinet shall be capable of withstanding 500-hour salt spray test per Federal Test Standard No. 141 (method 6061). E. Air-cooled condenser coils shall be leak tested at 573 psig. 1.03 Delivery. Storage. And Handling Units shall be shipped in one piece and shall be stored and handled per unit manufacturer's recommendations. 1.04 Warranty (For Inclusion By Specifying Engineer) PART 2 - PRODUCTS 2.01 Equipment A. General: Factory assembled, single piece, air-cooled outdoor unit. Contained within the unit enclosure shall be all factory wiring, piping, controls, and the compressor. B. Unit Cabinet: 1. Unit cabinet shall be constructed of galvanized steel, bonderized and coated with a baked -enamel finish on inside and outside. 2. Unit access panels shall be removable with minimal screws and shall provide full access to the compressor, fan, and control components. 3. Outdoor compartment shall be isolated and have an acoustic lining to assure quiet operation. 4. Compressor compartment shall be isolated to allow performing diagnostics while the system is running. C. Fans: 1. Outdoor fans shall be direct -drive propeller type, and shall discharge air horizontally. Fans shall blow air through the outdoor coil. 2. Outdoor fan motors shall be totally enclosed, single phase motors with class B insulation and permanently -lubricated bearings. Motor shall be protected by internal thermal overload protection. 3. Shaft shall have inherent corrosion resistance. 4. Fan blades shall be metallic and shall be statically and dynamically balanced. 5. Outdoor fan openings shall be equipped with PVC coated metal protective grille over fan. HORIZONTAL DISCHARGE OUTDOOR UNITS Model Number: 24AHA4/25HHA4/124ANS/224ANS Size Range: 1-1/2 to 4 - 1/2 Ton Nominal Cooling and Heating Capacity D. Compressor: 1. Compressor shall be fully hermetic scroll type. 2. Compressor shall be equipped with oil system, operating oil charge, and motor. Internal overloads shall protect the compressor from over -temperature and over -current. 3. Motor shall be NEMA rated class F, suitable for operation in a refrigerant atmosphere. 4. Compressor assembly shall be installed on rubber vibration isolators. 5. Compressors shall be available in single-phase (sizes 018-036) and three-phase (size 036). E. Outdoor Coil: Coil shall be constructed of aluminum fins mechanically bonded to seamless copper tubes, which are cleaned, dehydrated, and sealed. F. Refrigeration Components: Refrigerant circuit components shall include brass external liquid line service valve with service gage port connections, suction line service valve with service gage connection port, service gage port connections on compressor suction and discharge lines with Schrader type fittings with brass caps, accumulator, reversing valve. G. Controls and Safeties: Operating controls and safeties shall be factory selected, assembled, and tested. The minimum control functions shall include: 1. Controls: a. A time delay control sequence is provided standard through the fan coil board. b. Automatic outdoor -fan motor protection. 2. Safeties: a. Diagnostics provided by matched indoor unit. b. Compressor motor current and temperature overload protection. c. Outdoor fan failure protection (High Pressure Switch). d. Low pressure protection. e. Fusible plug to vent refrigerant safely in case of a fire. H. Electrical Requirements: 1. All sizes shall operate on single-phase, 60 Hz power at 208/230V or on three-phase, 60 Hz power at either 208/230 or 460 (for 36 & 48 size units). 2. Unit control voltage to the indoor -fan coil shall be 24 VDC. 3. All power and control wiring must be installed per NEC and all local electrical codes. I. J. Refrigerant Line Lengths: 1. The unit shall be capable of 200 ft (61 m) maximum piping, a maximum lift (fan coil above) of 65 ft (19.8 m) and a maximum drop (fan coil below) of 150 ft (45.8 m). Accessories will be required to achieve these lengths. Special Features (Field Installed): 1. Low -Ambient Kit: Control shall regulate fan -motor cycles in response to saturated condensing temperature of the unit. The control shall be capable of maintaining a condensing temperature of 100°F ± 10°F (37.78°C ± 5.5°C) with outdoor temperatures to -20°F (-28.9°C). Installation of kit shall not require changing the outdoor fan motor. 2. Crankcase Heater 3. Wind baffle 4. Stacking Kit 5. Wall Mounting Kit 24 25 Copyright 2015 CAC/BDP • 7310 W. Morris St. • Indianapolis, IN 46231 Edition Date: 08/15 Catalog No.40MKC(Q)B—F-01 PD Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. Replaces: NEW 26